Loading...
405 SKATE RD - ADDITION DRAWINGSU w ry 0 r w Z 0 O J Z 0 V) z O z Lu 0 z U-1 w c� J J z w w z Z w Z F - Q O ry z U-1 V) z O z w ry O ry r O 3 Q 0 - LL. V) O0 Q ON Ll_ Z �-o zF_ ZZ �0 �U Qo �z oQ oN LLJ J O °z w z� w J UJ �Q OoLL 0:� CL> LL, �p OQ n� wU Vw w U m J F— J OQ Z= JV) J ry QO V)U �Q a- L� w z UO Z U O UF- zQ X LLJ 00 rV oCL QQ �C) Qw _ce� Q� w w n F- - N �5Z w0 �w ryQ 3Lnvi Z 00 Z(/) �w Q:E -o 0 U� J w J w Z zz -Z �w w w Lu= z� Z�w Z v> Z �0 Q - 2z r., LU NEW MEMBRANE ROOFING BEAM HT. C? LANDING & 0o STAIRS (P) F.F.E (MATCH EXIST.) ,k- MA' EXI NEW CMU EXTERIOR WALLS, TYP. q Eo ASPHALT SHINGLES(E) CN z N O z Lo CMU EXTERIOR z �- WALLS, TYP. E > V UJ LL] 'n Lu Ie in O U LANDING & } STAIRS (P) U z F.F.E (MATCH EXIST.) _EMST. GRADE V Z J FRONT ELEVATION — LL 1/4" = 1'-0" Q � U Q Z Q = OU ASPHALT O SHINGLES(E) Q Z w LLI W O Lu > < w U v W U) Lo Z y O Q I 1 1-7- D "Zi- F___ I L I I 1 47O U LEFT ELEVATION 1/4" = 1'-0" LANDING & STAIRS (P) NEW S.G.D. w/ LANDING & STAIRS SCI REAR ELEVATION 1/4" = 1'-0" NEW S.G.D. w/ LANDING & STAIRS ASPHALT SHINGLES(E) RIGHT ELEVATION 1/4" = 1'-0" NEW MEMBRANE ROOFING BEAM HT. CMU EXTERIOR WALLS, TYP. o ASPHALT SHINGLES(E) F.F.E (MATCH EXIST. GRADE COMMUNITY DEVELOPMENT APPROVED v U .�.� 00 M � V O Ln ^N Z MSN �o Luz� N LL) M Lu N M v Q— > �- • Z Oz OU LL1 ceo �� _z Q V) i 0 .r LnNONE ■ ■ NONE PROJECT #: 18-304 DESIGNED: KCM DRAWN: KCM SCALE: AS NOTED ISSUED: 6/25/18 REVISION-]: 7/12/18 REVISION -2: SHEET A-1 U w ry 0 a, Lu > Z 0 V) 0 U- J Z O V) z O V) z w 2 0 z w 0 J V) CD z Q ry r) w J Q U 0 n J J Z o' w Lu Z Z w Z rV Q 0 U - z w V) Z 0 w o- ry 0 a- 0 Q �w u- V) 00 �Q ON u -Z zE_ zz �0 QU ,_o �Q ON Lu J O °z 3w z:2 00 W J UQ oLL >- Ory Lu Ci- L, > 0:�p a� Z OQ r-) �,z wU Nw :D= Lu U m J E_ J OQ Z= J N J � QO NU cn Q [� o_ w Z UO ZU O U w Z~ 2 CD _ N X Lu 00 0rya_ QQ Jn �W Lu �O QN 2z z0 w �w _ry �Q 3:110 Z �0 zN �Z Lu Q2 o' o n U ,ui J ui J Z Z -7 —Z Fv w ww w= z_ CD = z� w3 ZLn �Zz 0!�0 QN �Z �w 00 STAIRS, LANDINGS, GUARDS PER DETAILS & FBC R311 0 1 A-3 co IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ALL BUILDING RESTRICTION LINES AND CITY ZONING REQUIREMENTS BEFORE CONSTRUCTION BEGINS. z A-3 22'-24" L 10'-10„ 6'-4j„ 5-8j„ MODIFIED BITUMEN ROOFING OVER UNDERLAYMENT AND PLYWOOD OR OSB SHEATHING. 12 0.25SEE ENERGY FORMS FOR MIN. INSULATION SPECS. GAL. MTL. DRIP EDGE ON 1x P.T. =7------------ _--___---_ -_OVER 2x FASCIA PLYWOOD SORTS W/ 4"X12" SCREEN - I VENTS @ 48" O.C. HURRICANE TIES PER STRUCTURAL PLANS CONVENTIONAL ROOF FRAMING, 3050 S.H. , SEE STRUCTURAL PLANS 2x SILL PLATE w/ ANCHORS PER V/ STRUCTURALSHEETS 1 COURSE CONTINUOUS BOND BEAM PER STRUCTURAL SHEETS MASTER BEDROOM(P) BEDROOM 2(E) CLG HT: MATCH EXIST. EXTERIOR WALL COVERINGS TO 0 MATCH EXISTING I I 0 8"x16" CMU WALL w/ VERTICAL REINF. PER STRUCTURAL SHEETS i 3050 S.H. STEMWALL w/ REINF., SEE NLZ 11,_4„ STRUCTURAL SHEET FOR SPECS. 10'-10" STEMWALL FOOTING ON 4 COMPACTED SOILS,TYP. ` E \" ED 7777777777 2868 B}D. r 2468 C.0 c MASTER CLOSET(PP) I MASTER BATH(P) a CLG HT: MATCH EXIST. 1638 H CLG HT: MATCH EXIST. - - - - - - - - /HOWE\R O GARAGE E ---------- I I I I I I I I I I I I I WALL LEDGED NEW EXTERIOR WALLS NEW INTERIOR WALLS EXISTING WALLS TO REMAIN L—J O 42x22 (GUEST BATH( 'CLG HT: MATCH EXIST. REF. - - - - - RANGE/EXT. EXHAUST HOOD KITCHEN CLG HT: MATCH EXIST. 1101-1 Oil FRONT PORCH L PROPOSED FLOOR PLAN 1/4' V -0 - BEDROOM 1(E) LIVING ROOM(E) (�j FILL IN EXISTING WINDOW, SEE I �I� I STRUCTURALS 606 S.0 EXISTING ADDITION FRONT PORCH GARAGE TOTAL: ,L 1,044 S.F. 285 S.F. 36 S.F. 312 S.F. 1,677 S.F. STAIRS, LANDINGS, GUARDS PER DETAILS & FBC R311 BOND BEAM HT. (MATCH EXIST.) 2" GYP. BOARD FASTENED TO \ CEILING PER FBC. 1X4 P.T. FIRESTOP 2" GYP. BOARD ON 1X2 P.T. FURRING @ 16" O.C. W/ R-5 PAPER BACK FOIL INSULATION. 2x FLOOR JOISTS & LEDGER LEDGER, FASTENED TO STEMWALL PER STRUCTURAL SHEETS 6 MIL VAPOR BARRIER OR EQUIVALENT WATERPROOFING IN CRAWLSPACE 1 TYPICAL WALL SECTION Scale. 1/2 - 1-0 RAILINGS/GUARDS MIN 36" HIGH W/ MAX. OPENINGS B/T GUARDS OF 4". 2x6 No. 2 SYP PT DECKING. SEE FRAMING PLAN & DETAILS. DOUBLE 2x RIM JOIST W/ BLOCKING, SEE FRAMING PLAN FOR DETAILS. FASTEN EACH STRINGER TO BEAMS W/ SIMPSON HU12 HANGERS 2x12 WOOD STRINGERS EVERY 18" O.C. FASTENED TO TREADS/RISERS W/ MIN. #10x2-1/2" WOOD SCREWS. POST FOR LANDING/STAIRWAY - SUPPORTS, SEE FOUNDATION PLAN POST FTG. DETAIL. STAIR NOTES: MINIMUM 36" IN WIDTH. /4" AND MINIMUM AVE A MIN. WIDTH NO -S SERVED. TALL BE IN a BUILDING CODE, R317. LATE FASTENED TO 2 TYPICAL STAIR DETAIL LAB W/ 16" X 3" TAPCON :RY 12" O.C.(CONC. ONLY) COMMUNITY DEVELOPMENT APPROVED U U ME (D Z J Q0. a�V � p0 � °o 0 W Cn Z LL LO o J O �~ U a U 00 J CO M F - Q N T_ ti 00 V OON T_ z LoN O _O F- Z " a~. LLJ Ln o W W w 2 L� o O U U ME (D Z J Q0. a�V � p0 � °o 0 W Cn Z LL LO o J O �~ U a U J CO M OON Ln Z z--� Ln o W U. ,-- N L.t.l M N M V Q— > V z oz W QLu Z Lle) _ p ce V Id b, O \/ Ln ■ ■ SEEN ■ ■ ■ ■ PROJECT #: 18-304 DESIGNED: KCM DRAWN: KCM SCALE: AS NOTED ISSUED: 6/25/18 REVISION -1: 7/12/18 REVISION -2: SHEET A-3 I— U U C:f 0 LL. ry w Z O O LL_ J Z 0 V) z 0 V) z Lu 2 0 z w 0 Lu V) 0 z ryQ p w J Q U O 0 J J Z ry w w Z CD z w z 1— Q 0 u_ z w z 0 w ry 0 O 3 LLI LL_V) �m 00 �Q ON u- Z r0 z� z �0 �U Qp �z 0< ON Lu z J0 OZ Lu Z5- w J UQ p� Ow a> Lu �p � Z OQ p� Lu U Vw w U no J I— J OQ Z= J () J � Q0 2 � NU Ln Q Q_ wz U0 Z U O U Iii (D� cn X 00 pw zCL QQ Jn gcl� Q:fw wp Q'n 2Z z0 w Lu ry �Q 3V) V; Z 00 zN 3w Q2 Lynn p ULu J w J W Z z z _z � w ww w z� c� z Lu ZLn � Z QO �z w oQ r -- U -L NEW ROOF AREA 0.25/12 3-4/12 (MIN.) MEMBRANE ROOFING I I SEE FLASHING DETAILS FOR MATCH I WATERPROOFING EXIST. 3-4/12 NEW ROOF DATA (LINEAR FT.) SAVE LINE 40' GABLE LINE N/A RIDGE SINE N/A HIP LINE N/A VALLEY LINE N/A ROOF AREA 347 S. E. Lle%rr-. THE ABOVE ROOF DATA DOES NOT INCLUDE ROOF PITCH FACTOrS & CONSTRUCTION WASTE. 3-4/12 ROOF PLAN 1/4" = 1'-0" 3-4/12 3-4/12 AEMBRANE STRIP :OATED METAL DRIP MECHANICALLY ATTACH 3ERED 3" O.C. WELD TPO MEMBRANE METAL GUTTER 4NICALLY ATTACH NAILER 4EMBRANE -IED ADHESIVE ROOF DECK ATION (WHERE SPACER 36" O.C. -D ALTERNATELY H BRACKETS 3RACKET 36" O.C. NOTE: 1. ALL METAL SURFACES SHALL BE PRIMED BEFORE CONTACT MATH ANY ADHESIVE OR MASTIC. nR00FING &_ EDGE 6ETAIL A/C DISCONNECT GFI PROPOSED ELECTRICAL PLAN 1/4' - V -0 - CEILING FAN FLOURESCENT LIGHT LIGHT OUTLET GROUND FAULT INTERRUPT (All Waterproof) ARC FAULT INTERRUPT PENDANT LIGHT WALL MOUNTED LIGHT EXHAUST FAN/LIGHT FAN 0 N LY SWITCH THREEWAY ELECTRICAL LEGEND F/L 17 113 1 GCOMP. EYEBALL LIGHT RECESSED LIGHT SCONCE PRE -WIRE & BRACE DOOR BELL (LOW VOLTAGE) CABLE SMOKE DETECTOR/CARBON MONOXIDE FLOOD LIGHT GARBAGE DISPOSAL AUTOMATIC GARAGE DOOR BUTTON & SENSORS (LOW VOLTAGE) COMPRESSOR ALL PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL COMPLY WITH THE MINIMUM REQUIREMENTS FOR HIGH -EFFICACY LAMPS PER FBC-ENERGY CONSERVATION R404. Me Ln O 0 u) a~z z w ez W w 5; L1C in 0 0 0 z U CID M .5 ON., O Ln N NQ� f� _Z °C ` z -� Ln d' N O Lu W N M NNW-" J Q > 4 U Z Oz O L LJ °C O o` ILL. F_ _z F_ Q V) i--� i k c INV Ln ■ ■ ■ ■ PROJECT #: 18-304 DESIGNED: KCM DRAWN: KCM SCALE: AS NOTED ISSUED: 6/25/18 REVISION -1: 7/12/18 REVISION -2: SHEET OVA F -- U Lu rV ry 0 LL_ rtl Lu z 0 V) 0 LL_ J Z O V) Z 0 V) Z w O z w 0 w V) 0 Z_ Q ry p w J Q U V) 0 0 J z 5= w Lu Z z w z clfQ 0 Z w V) Z 0 w ry ry 0 ry w 0 Q �w LL.V) ry cc 00 afQ ON LL Z z� Qp z Z �0 �U Qp wz 0 Q OV) Lu 00 =z �w z2 pp LLJ -i �Q p� O0� CL > L, C)�,p QL- Z OQ p�,z wU cn w :D= Lu U m J F- J OQ Z = J ry Q =O V)U cn Q 0-� �F- wZ UO Z U O UF- -5 (D N X p0 ry pIL Z IL QQ Jp Qw �w wp F- QN 2z Z0 w F- w a= Q vi �Ln z z O Z LU pp ULu J w J W z_ Z0 E w w w w = Z_ z� Lu Z Ln �Z QO �Z �w C14 C) GENERAL STRUCTURAL NOTES THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOBSITE PRIOR TO COMMENCING WORK. CONTRACTOR SHALL REPORT ALL DISCREPANCIES THE DRAWINGS AND EXISTING CONDITION TO THE ENGINEER PRIOR TO COMMENCING WORK. DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE TYPICAL AND APPLY TO SIMILAR SITUATIONS ELSEWHERE, EXCEPT AS OTHERWISE INDICATED. ADAPT REQUIREMENTS OF DETAILS, SECTIONS, PLANS, AND NOTES AT LOCATIONS WHERE CONDITIONS ARE SIMILAR. DIMENSIONS INDICATED ON THE DRAWINGS IN REFERENCE TO EXISTING CONDITIONS ARE THE BEST AVAILABLE DATE OBTAINABLE, BUT ARE NOT GUARANTEED. BEFORE PROCEEDING WITH ANY WORK DEPENDENT ON THE DATA INVOLVED, THE CONTRACTOR SHALL FIELD CHECK AND VERIFY ALL DIMENSIONS, GRADES, LINES, LEVELS, OR OTHER CONDITIONS OF LIMITATIONS AT THE SITE TO AVOID CONSTRUCTION ERRORS. IF ANY WORK IS PERFORMED BY THE CONTRACTOR OR ANY OF HIS SUBCONTRACTORS PRIOR TO ADEQUATE VERIFICATION OF APPLICABLE DATA, AT RESULTANT EXTRA COST FOR ADJUSTMENT OR WORK AS REQUIRED TO CONFORM TO EXISTING LIMITATIONS, SHALL BE ASSUMED BY THE CONTRACTOR WITHOUT REIMBURSEMENT OR COMPENSATION BY THE OWNER. CENTER ALL FOOTINGS AND PIERS UNDER COLUMNS ABOVE UNLESS SPECIFICALLY DIMENSIONEDHERWISE. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND ARCHITECTURAL MECHANICAL, ELECTRICAL, PLUMBING, AND SITE DRAWINGS. CONSULT THESE DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS. CONTRACTOR SHALL LOCATE ALL BURIED UTILITIES PRIOR TO EXCAVATION FOR BUILDING FOUNDATIONS. THE STRUCTURAL ENGINEER SHALL BE NOTIFIED OF POTENTIAL CONFLICTS BETWEEN FOUNDATIONS AND BURIED UTILITIES. CODE REQUIREMENTS: THE BUILDING STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE 2017 EDITION OF THE FLORIDA BUILDING CODE 6TH EDITION. OTHER CODES IMPLEMENTED FOR DESIGN INCLUDE: ASCE7-10, ACI 315/318/530, NDS 2015, APA, A.I.S.C., ANSI. FOLLOW ALL APPLICABLE PROVISIONS OFT E FLORIDA BUILDING CODE AND OTHER RELATED CODES FOR ALL PHASES OF CONSTRUCTION. TEMPORARY CONDITIONS: THE STRUCTURAL INTEGRITY OF THE COMPLETED STRUCTURE DEPENDS ON INTERACTION OF VARIOUS CONNECTED COMPONENTS. PROVIDE ADEQUATE BRACING, SHORING, AND OTHER TEMPORARY SUPPORTS AS REQUIRED TO SAFELY COMPLETE THE WORK. THE STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR STABILITY UNDER FINAL CONFIGURATION ONLY. FOUNDATIONS: FOUNDATIONS ARE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PSF ON COMPACTED FILL. NO GEOTECHNICAL REPORTS AND/OR IN-SITU SOIL DATA WAS GIVEN TO THE STRUCTURAL ENGINEER PRIOR TO DESIGN. THE BEARING CAPACITY USED FOR DESIGN IS BASED ON ALLOWABLE LOADS FROM THE FLORIDA BUILDING CODE, 2017 FOR SANDY SOILS WITH NO CLAY, ORGANIC MATERIAL, OR OTHER DELETERIOUS MATERIALS THAT WOULD AFFECT DESIGN BEARING PRESSURE AND THE PERFORMANCE OF THE FOUNDATIONS. BEFORE CONSTRUCTION COMMENCES, SOIL BEARING CAPACITY SHALL BE VERIFIED BY A SUBSURFACE INVESTIGATION,AS WELL AS FIELD AND LABORATORY TESTS PERFORMED BY A CERTIFIED TESTING LABORATORY, WHOSE REPORT SHALL INCLUDE ANALYSIS AND RECOMMENDATIONS FOR SITE PREPARATION IN ORDER TO BEAR THE FOUNDATION LOADS. ABOVE REPORT SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW BEFORE FOUNDATION CONSTRUCTION BEGINS. CONCRETE: REINFORCED CONCRETE CONSTRUCTION SHALL CONFORM TO THE FBC AND ACI 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE". CONCRETE STRENGTHS SHALL BE VERIFIED BY STANDARD 28 -DAY CYLINDER TESTS PER ASTM C39, AND SHALL BE AS FOLLOWS: fc ABS W/C MIN CEMENTSLUMP USE 2,500 PSI 0.58 470 LBS 5" +/- 1 ALL SLABS, MONOLITHIC FOOTINGS, SPREAD FTG 3,000 PSI 0.58 470 LBS 5" +/- 1 TIEBEAMS, COLUMNS, WALLS, ELEVATED SLABS CEMENT SHALL CONFORM TO ASTM C150, TYPE 1. FLY ASH CONFORMING TO ASTM C618, TYPE FOR TYPE C, MAY BE USED TO REPLACE UP TO 20% OF THE CEMENT CONTENT, PROVIDED THAT THE MIX STRENGTH IS SUBSTANTIATED BY TEST DATA. COARSE AGGREGATE SHALL CONFORM TO ASTM C33 WITH A MAXIMUM SIZE OF 3/4". FINE AGGREGATE SHALL BE CLEAN, DURABLE, NATURAL SAND CONFORMING TO ASTM C33. A WATER -REDUCING ADMIXTURE CONFORMING TO ASTM C494, USED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, SHALL BE INCORPORATED IN CONCRETE DESIGN MIXES. A HIGH -RANGE WATER -REDUCING ADMIXTURE CONFORMING TO ASTM C494, TYPE F OR G, MAY BE USED IN CONCRETE MIXES, PROVIDING THAT THE SLUMP DOES NOT EXCEED 8". SLEEVES, OPENINGS, CONDUIT, AND OTHER EMBEDDED ITEMS NOT SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE APPROVED BY THE STRUCTURAL ENGINEER BEFORE POURING. NO SLEEVE, OPENING, OR INSERT MAY BE PLACED IN BEAMS, JOISTS, OR COLUMNS UNLESS APPROVED BY THE ENGINEER. CONDUITS EMBEDDED IN SLABS SHALL NOT BE LARGER IN OUTSIDE DIMENSION THAN ONE THIRD OF THE THICKNESS OF THE SLAB AND SHALL NOT BE SPACED CLOSER THAN THREE DIAMETERS ON CENTER. PROVIDE 3/4" CHAMFERS ON ALL EXPOSED CONCRETE EDGES, UNLESS NOTED OTHERWISE. WHERE INDICATED OR REQUIRED, SLOPE CONCRETE SLABS TO DRAINS SHOWN ON PLUMBING AND/OR ARCHITECTURAL DRAWINGS. ALL CONCRETE SHALL BE CURED IMMEDIATELY AFTER FINISHING OPERATIONS. WEATHER RESISTANCE: ALL CONCRETE INCLUDING BALCONY CONCRETE EXPOSED TO CHLORIDES SHALL CONTAIN A CALCIUM -NITRITE BASED CORROSION -INHIBITING ADMIXTURE. THE DOSAGE FOR CONCRETE EXPOSED TO AIRBORNE CHLORIDES SHALL BE MINIMUM TWO GALLONS PER CUBIC YARD. THE WATER CONTAINED IN THE CORROSION -INHIBITING ADMIXTURE SHALL BE USED IN THE CALCULATION OF THE WATER-TO-CEMENTITIOUS RATIO OF THE CONCRETE. PROVIDE RHEOCRETE CNI BY MASTER BUILDERS OR APPROVED EQUIVALENT. CONCRETE BALCONIES OR OTHER CONCRETE FLAT SURFACES EXPOSED TO THE WEATHER THROUGHOUT THE LIFE OF THE BUILDING, SHALL BE TREATED WITH A CLEAR NONFLAMMABLE PENETRATING SEALER OF THE ALKYL_ALKOXY SILANE CLASSIFICATION, SUCH AS SONNEBORN PENETRATING SEALER 20, HYDROZO ENVIROSEAL 20, OR OTHER APPROVED WEATHER RESISTANT SYSTEM. APPLICATION AND SURFACE PREPARATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. SHORING AND RESHORING: SHORING AND RESHORING SHALL CONFORM TO ACI 347R-88. SHORING AND SUPPORTING FORMWORK SHALL NOT BE REMOVED FROM HORIZONTAL MEMBERS BEFORE CONCRETE STRENGTH IS AT LEAST 70 PERCENT OF DESIGN STRENGTH, AS DETERMINED BY FIELD CURE CYLINDERS. IN ADDITION, SHORING SHALL NOT BE REMOVED SOONER THAN RECOMMENDED BY ACI 347R-88, SECTION 3.7.2.3. FORMWORK SHALL NOT BE REMOVED IN LESS THAN TEN (10) DAYS. PRECAST CONCRETE LINTELS: UNLESS INDICATED OTHERWISE, ALL LINTELS TO BE "U" TYPE PRECAST CONCRETE UNITS EQUAL TO UNITS MANUFACTURED BY CAST _CRETE CORP. AND PRESTRESSED (AND ADDITIONALLY REINFORCED AS REQUIRED) IN ACCORDANCE WITH CAST CRETE CORP. "DESIGN MANUAL", LATEST EDITION, FOR THE SPAN AND LOADING CONDITION RELATIVE TO LINTEL LOCATION. LINTEL SIZE IF NOT SHOWN ON THE PLANS SHALL BE 8F8-1 B FOR OPENINGS LESS THAN 10 FEET AND 8F16-1 B/1T FOR OPENINGS 10 FEET TO 20 FEET. PROVIDE 8" MINIMUM BEARING FOR LINTELS UNLESS NOTED OTHERWISE. WOOD: SAWN LUMBER SHALL BE SOUTHERN PINE #2 WITH THE ALLOWABLE FIBER STRESSES PER THE AWC NATIONAL DESIGN SPECIFICATION. ALL MANUFACTURED LUMBER SHALL BE 2.0E GLUED LAMINATED GEORGIA PACIFIC (OR EQUIV.) AND INSTALLED ACCORDING TO MANUFACTURES RECOMMENDATIONS. ALL HEADERS/BEAMS SHOULD BEAR FULLY ON POSTS AND/OR MULTI STUD GROUPS UNLESS NOTED OTHERWISE ON PLANS. CONTACT ENGINEER OF RECORD IF HEADER/BEAMS SIZE IS NOT SPECIFIED. FRAMING ACCESSORIES AND STRUCTURAL FASTENERS SHALL BE MANUFACTURED BY SIMPSON COMPANY OR USP (OR APPROVED EQUAL) AND OF THE SIZE AND TYPE SHOWN ON THE DRAWINGS. HANGERS NOT SHOWN SHALL BE SIMPSON HU OF SIZE RECOMMENDED FOR MEMBER. ALL CONNECTORS SHALL BE GALVANIZED. UNLESS SHOWN OTHERWISE, INSTALL MAXIMUM SIZE AND NUMBER OF FASTENERS SHOWN IN LATEST SIMPSON CATALOG ALL FRAMING NAILS SHALL BE COMMON NAILS AND SHALL BE OF THE SIZE AND NUMBER INDICATED ON THE DRAWINGS. MINIMUM NAILING REQ. NOT SHOWN SHALL BE AS INDICATED IN TABLE 2304.9.1 OF THE FBC. INSTALL 10d NAILS UNLESS OTHERWISE SPECIFIED ON THE PLANS OR DETAILS. BOLTS AND LAG SCREWS SHALL CONFORM TO ANSI/ASME STANDARD B18.1. ALL BOLTS AND LAG SCREWS SHALL BE INSTALLED WITH STANDARD CUT WASHERS. ALL ANCHOR BOLTS AND THREADED ANCHOR RODS SHALL BE IN ACCORDANCE WITH ASTM A307, GRADE A, OR ASTM F1554, GRADE 36. ANCHOR ADHESIVES SHALL BE EITHER SET (EPDXY-TIE) OR AT (ARCYLIC-TIE)l BY SIMPSON STRONG -TIE AND INSTALLED ACCORDING TO THE MANUFACTURES INSTRUCTIONS. ALL DRILLED ANCHOR HOLES SHALL BE CLEANED OF ALL DEBRIS AND BRUSHED OUT PRIOR TO INSTALLATION OF ANCHOR ADHESIVE. ALL WOOD MEMBERS EXPOSED TO EXTERIOR CONCRETE, MASONRY, WEATHER, OR EARTH SHALL BE PRESSURE TREATED LUMBER. ALL NAILS DIRECTLY EXPOSED TO WEATHER SHALL BE GALVANIZED. FASTENER REQUIREMENTS IN PRESSURE TREATED LUMBER ARE AS FOLLOWS: ACZA PRESERVATIVE: STANDARD CARBON STEEL. ACQ & MCQ PRESERVATIVE: HOT DIPPED GALVANIZED. SODIUM BORATE: STAINLESS STEEL CONNECTORS & FASTENERS (NOT REQ. FOR SILL PLATES OVER CONCR. & VAPOR BARRIER NOT DIRECTLY EXPOSED TO EARTH OR WEATHER) ALL DECKS, GUARDS, RAILS, STAIRS AND OTHER ACCESSORY DECK COMPONENTS SHALL BE CONSTf UCTED IN ACCORDANCE WITH AWC DCA6 PRESCRIPTIVE GUIDE FOR DECK CONSTRUCTION & THE FLORIDA BUILDING CODE, 2017. ALL FASTENERS AND CONNECTORS EXPOSED TO SALT WATER OR LOCATED WITHIN 300 FEET OF A SALT WATER SHORE LINE SHALL BE STAINLESS STEEL GRADE 304 OR 316 ALL EXTERIOR WOOD WALLS WITHOUT OPENINGS SHALL BE CONSIDERED SHEAR WALLS. ALL WOOD DESIGN SHALL BE IN ACCORDANCE WITH THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, 2015 & WITH THE FLORIDA BUILDING CODE, 2017. PLYWOOD PANELS SHALL CONFORM TO THE REQUIREMENTS OF "U.S. PRODUCT STANDARD PS -1 FOR CONSTRUCTION AND INDUSTRIAL PLYWOOD" OR APA PRP -108 PERFORMANCE STANDARDS. UNLESS OTHERWISE NOTED, PANELS SHALL BE APA RATED SHEATHING, EXPOSURE 1, OF THE THICKNESS AND SPAN RATING SHOWN ON THE DRAWINGS. PLYWOOD INSTALLATION SHALL BE IN CONFORMANCE WITH APA RECOMMENDATIONS. ALLOW 1/8" SPACING AT PANEL EDGES, UNLESS OTHERWISE RECOMMENDED BY THE PANEL MANUFACTURER. ALL SUB -FLOORING, ROOF, AND SHEARWALL SHEATHING SHALL BE INSTALLED WITH FACE GRAIN PERPENDICULAR TO SUPPORTS, EXCEPT AS INDICATED ON THE DRAWINGS. STAGGER _NDS OF ADJACENT PANELS 4'-0". ROOF SHEATHING SHALL BE BLOCKED, TONGUE -AND -GROOVE, OR HAVE EDGES SUPPORTED BY PLYCLIPS. ATTACH PLYWOOD PANELS TO SUPPORTING MEMBERS WITH 10d NAILS SPACED 4" ON CENTER ALONG THE PANEL EDGES AND AT 6" ON CENTER ALONG INTERMEDIATE SUPPORTS, UNLESS NOTED OTHERWISE. SUB -FLOORING SHEATHING SHALL BE UNBLOCKED, EXCEPT AS INDIC TED ON DRAWINGS. ATTACH PLYWOOD PANELS TO SUPPORTING MEMBERS WITH 8d NAILS SPACED 4" ON CENTER ALONG THE PANEL EDGES AND AT 8" ON CENTER ALONG INTERMEDIATE SUPPORTS, UNLESS NOTED OTHERWISE. PREFABRICATED WOOD TRUSSES: SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGN INTENT OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC. CONTRACTOR SHALL NOT BE RELIEVED FROM RESPONSIBILITY FOR ERRORS OR OMISSIONS IN SH P DRAWINGS OR MIX DESIGNS BY THE ENGINEER'S REVIEW. DESIGN AND MANUFACTURE IN ACCORDANCE WITH TPI "DESIGN SPE IFICATIONS FOR METAL PLATE CONNECTED WOOD TRUSSES", LATEST EDITION. ROOF TRUSS LOADING: SEE TRUSS MANUFACTURES SIGNED AND SE L TRUSS SHOP DRAWINGS FOR APPLICABLE TRUSS DESIGN LOADS. TRUSS LOADINGS SHALL BE BASED ON THE P OJECTS DESIGN LOADS AND THE MINIMUM LOAD REQUIREMENTS SET FORTH BY ASCE 7-10 AND THE FLORIDA BUILDING CODE, 2017 RESIDENTIAL. ALL TRUSS TO TRUSS CONNECTIONS TO BE DESIGNED BY TRUSS MA UFACTURER AND MADE USING TRUSS HANGERS. TRUSS DIAGRAMS, IF SHOWN, ARE DIAGRAMMATIC ONLY. TRUSS DESIGNER TO DETERMINE AND ESTABLISH EXACT HEIGHT, LENGTH, LOCATION, SPACING, AND WEB MEMBER FOR EACH TRUSS. COORDINATE WITH ARCHITECTURAL AND MECHANICAL DRAWINGS FOR ADDITIONAL, ITEMS INCLUDING AIR HANDLER LOCATIONS, MECHANICAL ROOMS AND DUCT SPACE AND ROUTING. BUILDER SHALL COORDINATE WITH TRUSS DESIGNER FOR PERMANENT TRUSS BRACING. IF NO BRACING INFORMATION IS PROVIDED, BOTTOM CHORD LATERAL BRACING SHALL BE CONTINUOUS FROM ONE END OF THE BUILDING TO THE OTHER AND SHOULD OVERLAP AT LEAST ONE TRUSS SPACE FOR CONTINUITY. LATERAL BRACING SHALL BE NAILED TO EACH TRUSS WITH A MIN. OF (2) 16d NAILS INCLUDING INTERMEDIATE TRUSSES. SEE TRUSS SHOP DRAWINGS FOR OTHER DETAILS AND SPECIFICATIONS FOR BRACING. REINFORCING STEEL: REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, FOR DEFORMED BAR AND ASTM A185 FOR SMOOTH WELDED WIRE FABRIC (WWF), UNLESS OTHERWISE NOTED. REINFORCING STEEL TO BE WELDED SHALL CONFORM TO ASTM A706. REINFORCING STEEL SHALL BE SECURELY TIED IN PLACE WITH #16 ANNEALED IRON WIRE, ALL DETAILING AND ACCESSORIES SHALL CONFORM TO ACI DETAILINMANUAL SP_66. PROVIDE CHAIRS, SPACERS, BOLSTERS, AND ITEMS IN CONTACT WITH FORMS WITH HO _DIP GALVANIZED LEGS OR PLASTIC LEGS. ACCURATELY POSITION, SUPPORT, AND SECURE REINFORCEMENT A AINST DISPLACEMENT BY FORMWORK CONSTRUCTION OR CONCRETE PLACEMENT OPERATIONS. "WET -STI 'KING" OF REINFORCING IS PROHIBITED. REQUIRED CONCRETE COVER FOR REINFORCING STEEL (UNLESS NO ED OTHERWISE): FOOTINGS 3" BOTTOM AND SIDES, 2" TOP SLABS 3/4" COLUMNS 1-1/2" TO TIES, 2" TOP BEAMS 1-1/2" TO STIRRUPS WALLS 1-1/2" LAP SPLICE CONTINUOUS VERTICAL OR HORIZONTAL BARS IN CONCR _TE MEMBERS IN ACCORDANCE WITH ACI 318, LATEST EDITION, FOR CLASS "B" TENSION LAP SPLICES. DO NOT 'PLICE CONTINUOUS TOP BARS IN BEAMS AT ENDS OF CLEAR SPANS. DO NOT SPLICE CONTINUOUS BOTTOM BARS IN BEAMS IN CLEAR SPANS BETWEEN SUPPORTS. SHOW ALL SPLICES ON SHOP DRAWINGS. SPLICE LOCAT ONS AND IN SUBJECT TO APPROVAL OF STRUCTURAL ENGINEER. AT SLAB AND WALL OPENINGS PROVIDE A MINIMUM OF (2) #5 BARS AL FOUR SIDES AND DIAGONALLY; EXTEND THESE BARS A LAP DISTANCE OR A MINIMUM OF 24" PAST THE OPENING OR HOOK BARS IF DISCONTINUOUS. DOWEL ALL WALLS AND COLUMNS TO FOOTINGS WITH BAR SIZE AND SPACING TO MATCH VERTICAL REINFORCING UNLESS OTHERWISE SHOWN. MASONRY WALLS: MASONRY UNITS SHALL MEET ASTM C90, TYPE 2. ASSEMBLIES SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF fm= 1500. MORTAR SHALL BE TYPE "M" OR "S" AND MEET ASTM C2 0. GROUT SHALL BE 2000 PSI MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS IN ACCORDANCE WITH ASTM C476. GROUT SHALL CONSIST OF A MIXTURE OF CEMENTITIOUS MATERIALS AND AGGREGATE TO WHICH SUFFICIE T WATER HAS BEEN ADDED TO CAUSE THE MIXTURE TO FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. GROUT SHALL HAVE A MAX. COURSE AGGR. SIZE OF 8" & SHALL BE PLACE WITH A SLUMP OF 8 TO 11 INCHES. ALL ELLS CONTAINING VERTICAL BARS, BOND BEAMS, AND ALL CELLS BELOW GRADE SHALL BE FILLED WITH GROUT. MAXIMUM HEIGHT OF GROUT POUR ALLOWED IS 5-0" UNLESS CLEAN-OUT OPENING IS PROVIDED AT BOTTOM OF CELLS TO BE FILLED. LOCATE CLEAN-OUT OPENINGS IN AREAS NOT EXPOSED TO VIEW. CLEAN OUT OPENINGS SHALL HAVE A MIN, OPENING DIMENSION OF 3 INCHES. UNLESS NOTED OTHERWISE EIGHT INCH MASONRY WALLS SHALL BE )ARTIALLY REINFORCED MASONRY WALL CONSTRUCTION WITH #5 AT 48 INCH O.C. IN GROUT FILLED CELLS. AD (1) #5 REINFORCING BAR EACH SIDE OF OPENINGS EXCEEDING 3 FEET. PROVIDE REINFORCING BARS AT CORNERS, INTERSECTIONS, AND EA''H SIDE OF OPENINGS. PROVIDE (2) REINFORCING BARS EACH SIDE OF OPENINGS OVER 4 FEET WIDE, AN ) AS SHOWN ON THE PLANS. PROVIDE HOOKED DOWELS INTO FOOTINGS AND STRUCTURE ABOVE AND/OR BELOW TO PROVIDE CONTINUITY. PROVIDE 9 GAGE GALVANIZED HORIZONTAL JOINT REIN-ORCING (DUR-O-WAL OR ENGINEER -APPROVED EQUAL) AT 16" O.C. DO NOT PLACE CONDUITS, PIPES, ETC., IN CELLS WITH VERTICAL REINFORCING. DO NOT RUN CONDUITS, PIPES, ETC., HORIZONTALLY IN CMU WALLS PARALLEL TO LENGTH OF WALL. WHERE MASONRY WALLS ABUT CONCRETE COLUMNS TO BE PLACED PRIOR TO ERECTION OF MASONRY WALLS, ROVIDE DOVETAIL SLOTS BETWEEN COLUMN AND WALLS AND GROUT THE CMU CELL CONTAINING THE DOVETAIL A CHORS. OTHERWISE, EXTEND CMU HORIZONTAL JOINT REINFORCING THROUGH CONCRETE COLUMN. CONTROL JOINTS SHALL BE PROVIDED IN ALL CONCRETE MASONRY CONSTRUCTION AT LOCATIONS INDICATED ON THE ARCHITECTURAL DRAWINGS. HORIZONTAL WALL REINFORCING SHALL BE STOPPED EACH SIDE OF CONTROL JOINTS. SEE ARCHITECTURAL DRAWINGS FOR SEALANT REQUIREMENTS AT CONTROL JOINTS. USE METAL LATH OR WIRE SCREEN FOR CAVITY CAPS. SHEET METAL FELT, BUILDING PAPER, OR LIKE MATERIALS ARE PROHIBITED. CHEMICAL ADHESIVE ANCHORING IN HOLLOW CELL APPLICATIONS ADHESIVE ANCHORS (EPDXY STYLE) SHALL BE USED IN HOLLOW CMU APPLICATIONS FOR STRUCTURAL ANCHORING. ANCHORS SHALL BE TESTED TO ASTM E488 AND ICBO A '58. ICBO AND/OR SBCCI CODE COMPLIANCE IS REQUIRED IN APPROPRIATE AREAS. METRO-DADE COMPLIANCE AND/OR FLORIDA BUILDING CODE COMPLIANCE ARE REQUIRED IN FLORIDA. ANCHORING SYSTEM SHALL INCLUDE THE ADHESIVE, MESH SCREEN (OR UMBRELLA), ANCHOR (OR INSERT) AND WASHER/NUT FOR PROPER ANCHORING. ACCEPTED PRODUCTS ARE ITW RED HEAD ACRYLIC 7, GRANITE 5 OR ENGINEER APPROVED SUBSTITUTION. ADHESIVE SHALL BE MOISTURE INSENSITIVE (ALLOWING INSTALLATIONS IN DAMP OR WATER -FILLED HOLES). ADHESIVE SHALL HAVE A FULL -CURE LOAD OF 2 HOURS OR LESS AT 70°F OR SAFETY ISSUES. MESH SCREENS SHALL BE FORMED INTO A CYLINDRICAL SHAPE WITH ONE END CLOSED. ALTERNATELY, UMBRELLA SUPPLIED BY ITW RED HEAD MAY BE USED IN APPROPRIA E APPLICATIONS. THREADED STUDS SHALL CONFORM TO ASTM A36 (STANDARD CARBON STEEL) UNLESS NOTED OTHERWISE. PERMANENTLY EXPOSED STUDS SHALL BE STAINLESS STEEL. NUTS AND WASHERS SHALL CONFORM TO THE SAME SPECIFICATION AS THE SUPPLIED STUD. INSTALLATION SHALL BE IN CONFORMANCE WITH MANUFACTURER'S PRINTED LITERATURE. INSTALLATION SHALL ALSO INCLUDE BRUSHING AND CLEANING OF DRILLED HOLES WITH COMPRESSED AIR AS INSTRUCTED. INSTALLERS SHALL BE TRAINED BY THE MANUFACTURER'S REPRESENTATIVE. EMBEDMENT SHALL BE AS INDICATED ON THE STRUCTURAL DRAWINGS. DESIGN CRITERIA: DESIGN WAS BASED ON STRENGTH AND DEFLECTION CRITERIA OF THE 2017 FLORIDA BUILDING CODE 6TH EDITION. IN ADDITION TO THE DEAD LOADS, THE FOLLOWING LOADS AND ALLOWABLES WERE USED FOR DESIGN, WITH LIVE LOADS REDUCED PER THE 2017 FBC: L/360 - L/240 L/360 - L/240 L/240 - BRITTLE L/180 - FLEXIBLE THE PROPOSED WORK SHALL BE IN ACCORDANCE WITH THE PRESCRIPTIVE COMPLIANCE METHOD PER CHAPTER 4 OF THE 2017 FLORIDA BUILDING CODE, EXISTING, 6TH EDITION. WIND PRESSURES ON WALLS & ROOFS 3 EFFECTIVE AREA OF LIVE LOAD DEAD LOAD ROOF: 20 PSF 15 PSF FLOORS: 40 PSF 15 PSF DECKS: 50 PSF 15 PSF WALLS: PER C&C PER ASCE7-10 -100.2 BELOW TBLE. C3-1 ULTIMATE WIND SPEED -57.0 130 MPH PER ASCE 7-10 NOMINAL WIND SPEED: -37.8 101MPH PER FBC R301.2.1.3 EXPOSURE 22.4 C PER ASCE 7-10 IMPORTANCE FACTOR -44.2 1.0 CATEGORY II INTERNAL PRESSURE COEFF +/-0.18 ENCLOSED (PROTECTED OPENINGS) COMPONENTS & CLADDING PRESSURES PER TABLE & CHARTS ON THIS PAGE. L/360 - L/240 L/360 - L/240 L/240 - BRITTLE L/180 - FLEXIBLE THE PROPOSED WORK SHALL BE IN ACCORDANCE WITH THE PRESCRIPTIVE COMPLIANCE METHOD PER CHAPTER 4 OF THE 2017 FLORIDA BUILDING CODE, EXISTING, 6TH EDITION. WIND PRESSURES ON WALLS & ROOFS 3 EFFECTIVE AREA OF ROOF ZONES' EXTERIOR WALLS' OPENING/ROOF ZONE INTERIOR ZONE 1 EDGE ZONE 2 CORNER ZONE 3 INTERIOR ZONE 4 END ZONE 5 0 to 10 24.5 -38.9 24.5 -67.8 24.5 -100.2 42.6 -46.2 42.6 -57.0 10.1 to 20 22.4 -37.8 22.4 -62.4 22.4 -93.8 40.6 -44.2 40.6 -53.2 20.1 to 50 19.5 -36.4 19.5 -55.2 19.5 -85.1 38.1 -41.7 38.1 -48.0 50.1 to 100 17.4 -35.3 17.4 -49.8 17.4 -73.1 36.3 -39.8 36.3 -44.2 100.1 to 500 - - - - - - 31.8 1 -35.3 31.8 -35.3 1. WIND PRESSURES SHOWN ABOVE ARE FOR STRUCTURES WITH A MEAN ROOF HEIGHT OF 30 FEET OR LESS WITH A ROOF PITCH BETWEEN 2/12 & 6/12 (VERT./HORIZ.). IF THE STRUCTURE IS OUTSIDE THESE PARAMETER PLEASE CONTACT THE ENGINEER. 2. THE EFFECTIVE AREA IS EQUAL TO THE LENGTH , WIDTH OF THE PROPOSED OPENING OR SPAN. THE WIDTH SHALL BE PERMITTED TO BE NOT LESS THAN 1 OF THE SPAN LENGTH. THE EFFECTIVE AREA FOR FASTENERS SHALL NOT BE GREATER THAN THE TRIBUTARY AREA B/T FASTENERS. 3. ALL WIND PRESSURE VALUES IN POUNDS PER SQ. FT(PSF) & ARE CONSIDERED ULTIMATE VALUES. MULTIPLY VALUES BY 0.6 FOR NOMINAL PRESSURES PER FBC R301.2.1.6 ZONE CHARTS a a a a 1 Ti ---- - 2-------7 ; �J--------- 2 ---------LOOS N 2' / /2 A 01 102 h a \2 -- ----/ I 1 2 4 < 2 / O I a �I 0 Oj / �1 qa 0 4 / / 4 ------ 2/ � O �`OI O 10 1001 / � � I I --_-- _ , o- _--_-- 2- aHIP ROOFS a a GABLE ROOFS a WALLS ABBREVIATIONS BM BEAM B/T BETWEEN CONN. CONNECTION CONT. CONTINUOUS CL CENTER LINE CLG CEILING CMU CONCRETE MASONRY UNIT DL DEAD LOAD EOR ENGINEER OF RECORD EXT. EXTERIOR FBC FLORIDA BUILDING CODE (2017, 6TH EDITION) FFE FINISHED FLOOR ELEVATION FTG FOOTING FPA FLORIDA PRODUCT APPROVAL INT. INTERIOR LG LENGTH LL LIVE LOAD LVL LAMINATED VENEER LUMBER (2.OE, 1 4" WIDE MIN. U.N.O.) MAX. MAXIMUM MIN. MINIMUM OR "OR" MEANS THAT EITHER OPTION PROVIDED IS SUFFICE FOR THE APPLICATION O.C. ON CENTER SPACING OPT OPTIONAL OSB ORIENTED STAND BOARD (APA RATED MIN.) PCF POUNDS PER SQUARE FEET PLYW. PLYWOOD (APA RATED MIN.) PSF POUNDS PER SQUARE FEET PSI POUNDS PER SQUARE INCH SS STAINLESS STEEL STAGG. STAGGERED SPF SPRUCE -PINE -FIR SYP SOUTHERN YELLOW PINE (No. 2 MIN.) SW SHEAR WALL T/G TOGETHER T&G TONGUE AND GROOVE TYP TYPICAL U.N.O. UNLESS OTHERWISE NOTED W/ WITH W/o WITHOUT W.W.M/F WELDED WIRE MESH OR FABRIC SHEETINDEX S-1 STRUCTURAL NOTES & SPECIFICATIONS S-2 FOUNDATION & FRAMING PLAN S-3 ROOF FRAMING PLANS & DETAILS SYMBOLLEGEND VIEW DIRECTION ::�_, xiiDETAIL/SECTION NUMBER WALL SECTION WALL SECTION 1 S-1 LOCATION OF SECTION CUT SHEET No. WHERE V SECTION IS LOCATED. Ln DETAIL/SECTION NUMBER ELEVATION 1 S-1 VIEW DIRECTION ,- SHEET No. WHERE SECTION IS LOCATED. Z DETAIL/SECTION NUMBER DETAIL 1 N S-1 SHEET No. WHERE Z SECTION IS LOCATED. CALL OUT FA] CUT/ MATCH LINE - - ELEVATION DATUM •-- SLAB STEP X (INCHES) W N z 0 t/1 > ILLI I - a V cn W in 6 Z 00 N irn U) I_ Z W O U f- ok • U .J 00 M V Q Ln ,- N Z *k C'4 0, N 0 "0 Z Ln d- N O •-- L.0 �"� W N M z���Q - V Q Z oz 0U LLl 9:4 0 0` rte. ~' _Z Q Q O .. Ln PROJECT #: 18-304 DESIGNED: KCM DRAWN: KCM SCALE: AS NOTED ISSUED: 6/25/18 REVISION -1: 7/12/18 REVISION -2: OP d ► ; r' 141 r w STATE Of 0",C) A sti � , . �� •� rrffr0NA'L SHEET S-1 w w w z CD z w Lu 2 2 3 V) z O v) z Lu 0 U w O U LL_ w Lu Z O 2 N r - O Z w J Z O V) Z _O Ln Z Lu 0 Z w V W N V Z Q 0 Lu Q V) F_ O z O 0 z w Lu z z Lu z Q O z Lu V) z O U z w D_' 3 O O Q O w O O r Z Q Z Q w O W O 2 Z 0 w U 0 O ryO Lu D_' ry O 0 Lu V) _ w m F -- O z J J Q C w D_ Lu U "' Z m O O U z Q �N L„ z w Q 0 0 0 Q O U Q o oo� z w Q Qz z O V) w Z Lu 3 0 z Qr Q w o > 0 U z J Q LU z 2 w U w J _Z - U2 Z V) w W z O U 00 Z E) 0 GENERAL NOTES 1. IT IS THE INTENT THAT THIS WORK BE IN CONFORMANCE WITH THE FLORIDA BUILDING CODE 2017, 6TH ED. RESIDENTIAL AND ALL AUTHORITIES HAVING JURISDICTION OVER THIS TYPE OF CONSTRUCTION AND OCCUPANCY. CONTRACTOR SHALL DO THEIR WORK IN CONFORMANCE WITH ALL APPLICABLE CODES AND REGULATIONS. 2. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOBSITE PRIOR TO COMMENCING WORK. CONTRACTOR SHALL REPORT ALL DISCREPANCIES THE DRAWINGS AND EXISTING CONDITION TO THE ENGINEER PRIOR TO COMMENCING WORK. 3. THESE DOCUMENTS, AS INSTRUMENTS OF SERVICE, ARE THE PROPERTY OF THE ENGINEER AND MAY NOT BE USED OR REPRODUCED WITHOUT EXPRESSED WRITTEN CONSENT OF THE ENGINEER. 4. ALL DETAILS AND SECTIONS SHOWN ON THESE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE IN THE WORK, EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. 5. CONTRACTOR WILL INCORPORATE ALL NECESSARY LOCAL/STATE/FEDERAL BUILDING, FIRE, AND HANDICAP CODES INTO THE DESIGN AND BASE PROPOSAL FOR A COMPLETE TURN -KEY PROJECT, 6. PROJECT SHALL BE TURNED OVER TO OWNER IN A CLEAN CONDITION WITH ALL TRASH AND DEBRIS REMOVED FROM SITE. ALL WINDOWS AND CLASS CLEAN, ALL FLOORS CLEAN, ALL HORIZONTAL SURFACES DUSTED AND CLEANED, AND ALL PLUMBING AND TOILET FIXTURES CLEAN AND IN GOOD WORKING ORDER. CONTRACTOR SHALL HAUL ALL RUBBISH FROM SITE ON A REGULAR BASIS. DO NOT ALLOW TO ACCUMULATE. 15. CONTRACTOR TO OBTAIN ALL PERMITS, PAY ALL FEES AND TAXES. CONTRACTOR SHALL GUARANTEE ALL MATERIALS & WORKMANSHIP FREE FROM DEFECTS. FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM THE DATE OF ACCEPTANCE. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE ION AND SHALL INCLUDE INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 16. DIMENSIONS INDICATED ON THE DRAWINGS IN REFERENCE TO EXISTING CONDITIONS ARE THE BEST AVAILABLE DATE OBTAINABLE, BUT ARE NOT GUARANTEED. BEFORE PROCEEDING WITH ANY WORK DEPENDENT ON THE DATA INVOLVED, THE CONTRACTOR SHALL FIELD CHECK AND VERIFY ALL DIMENSIONS, GRADES, LINES, LEVELS, OR OTHER CONDITIONS OF LIMITATIONS AT THE SITE TO AVOID CONSTRUCTION ERRORS. IF ANY WORK IS PERFORMED BY THE CONTRACTOR OR ANY OF HIS SUBCONTRACTORS PRIOR TO ADEQUATE VERIFICATION OF APPLICABLE DATA, AT RESULTANT EXTRA COST FOR ADJUSTMENT OR WORK AS REQUIRED TO CONFORM TO EXISTING LIMITATIONS, SHALL BE ASSUMED BY THE CONTRACTOR WITHOUT REIMBUR EMENT OR COMPENSATION BY THE OWNER. 17. A DESIGNATED LOCATION FOR STORAGE OF CONSTRUCTION MATERIAL AND EQUIPMENT SHALL BE DETERMINED BY THE OWNER AND IDENTIFIED AT THE PRE -CONSTRUCTION MEETING. 18. CONTRACTOR PERSONNEL ARE CONFINED TO AREAS OF BUILDING NECESSARY FOR COMPLETION OF WORK. FREE ACCESS TO ALL PARTS OF THE BUILDING IS NOT ALLOWED. 19. CONTRACTOR IS RESPONSIBLE FOR SCHEDULING DELIVERY, RECEIVING, UNLOADING, UNCRATING, SORTING, SETTING IN PLACE, AND PROTECTING FROM DAMAGE ALL NEW EQUIPMENT FURNISH D BY THE CONTRACTOR. THIS SHALL ALSO APPLY TO ITEMS FURNISHED BY THE OWNER TO THE CONTRACTOR. 20. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, BAITING SYSTEMS, AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. UPON OMPLETION OF THE APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIAN E SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CON INS THE FOLLOWING STATEMENT: THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS ESTABLISHED BY FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. 21. TERMITE PROTECTION TO BE DONE AFTER ALL EXCAVATION, BACKFILLING AND COMPACTION IS COMPLETE. ANY DISTURBED SOIL TREATMENT MUST BE RETREATED. 22. TREATMENT SHALL BE PROTECTED FROM RAINFALL BY 6 MIL VAPOR BARRIER. IF RAINFALL OCCURS BEFORE BARRIER PLACEMENT, SOIL MUST BE RETREATED. 23. PROTECTIVE SLEEVES AROUND METALLIC PIPING PENETRATING CONCRETE SLAB -ON -GRADE FLOORS SHALL BE NON -CELLULOSE CONTAINING MATERIALS AND RECEIVE AN APPLICATION OF TERMITICIDE IN ANNULAR SPACE BETWEEN SLEEVE AND PIPE. NEW ADDITION 405 SKATE ROAD ATLANTIC BEACH ELECTRICAL NOTES 1. ALL ELECTRICAL WIRING TO BE IN ACCORDANCE WITH 2017 FLORIDA BUILDING CODE, 6TH EDITION, RESIDENTIAL AND 2011 NATIONAL ELECTRIC CODE 2. ALL SMOKE DETECTORS AND CARBON MONOXIDE DETECTORS SHALL BE IN ACCORDANCE WITH THE 2017 FBC R314 & R315. 3. ELECTRICAL CONTRACTOR SHALL PROVIDE ARC -FAULT CIRCUIT INTERRUPTERS IN LIVING, DINING, HALLWAYS, AND BEDROOMS PER 2017 FBC R3902.16 4. ALL OUTDOOR RECEPTACLES SHALL BE PROT CTED FROM MOISTURE PER 2017 FBC R3905.11 5. ALL PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL COMPLY WITH THE MINIMUM REQUIREMENTS PER FBC-ENERGY CONSERVATION R404. 6. STAIRWAY ILLUMINATION FOR BOTH INTERIOR �ND EXTERIOR STAIRWAYS SHALL BE IN ACCORDANCE WITH THE 2017 FBC R303.7 & R303.8 MECHANICAL NOTES 1. ALL DUCT SIZING SHALL BE IN ACCORDANCE W/ ACCA MANUAL "D". PROVIDE DUCT TESING IN ACCORDANCE W/ ASHRAE STANDARD 152. 2. DUCT LAYOUT AND ALL OTHER MECHANICAL COMPONENTS ARE SHOWN ON THE APPROVED DUCT LAYOUT PLAN INCLUDED IN THE ENERGY CALCULATION PAC 'AGE PERFORMED BY OTHERS. 3. ALL DUCTS & AIR HANDLERS NOT LOCATED IN CONDITIONED SPACE SHALL BE TESTED TO BE "SUBSTANTIALLY" A-2 LEAK FREE. INTERNATIONAL AIR T FLOOR PLAN 4. DUCTS IN GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE -S-1-S-3 GARAGE SHALL BE INSTALLED ACCORDING TO FBC R302.5.2 5. VENTILATION REQUIREMENTS SHALL BE IN ACCORDANCE WITH THE 2017 FBC R303. yy P 6. ALL INSULATION SPECIFICATIONS ARE INCLUD .D IN THE ENERGY CALCULATION PACKAGE PERFORMED BY ROAD 2 N OTHERS. IF ANY INSTALLED INSULATION MATE IALS DO NOT MATCH THE ENERGY FORMS, NEW CALCULATIONS � p�FiL` FAVE 2 SHALL BE PERFORMED OR THE ORIGINAL AP ROVED INSULATIONS SHALL BE INSTALLED. R PLUMBING NOTES 1. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST-CLASS WORKMANLIKE MANNER. THE COMPLETE SYSTEM SHALL BE FULLY OPERATIVE. 2. ALL EXCAVATION & BACK FILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL BE A PART OF THIS CONTRACT, 3. ALL WORK SHALL BE COORDINATED WITH OT ER TRADES TO A VOID INTERFERENCE WITH THE PROCESS OF CONSTRUCTION. 4. VERIFY LOCATION, SIZE, TRAPS, INVERTS OF ALL EXISTING UTILITIES PRIOR TO BEGINNING CONSTRUCTION. ADVISE ENGINEER OF ANY DISCREPANCIES. ANY COST RES UL TING FROM DISCREPANCIES NOT REPORTED AT THIS TIME SHALL BE PAID BY THE CONTRACTOR. 5. WATER PIPING TO BE CROSS-LINKED POLYETNiYLENE PIPE (PEX), PVC, OR TYPE "M" OR TYPE "L" COPPER ABOVE OR BELOW GRADE. ALL PIPING SHALL BE IN ACCORDANCE WITH SECTION P2906.4 OF THE 2017 FLORIDA BUILDING CO E, RESIDENTIAL. 6. SOIL, WASTE & VENT PIPING TO BE PVC. #4 DVW. 7. ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE STOPS 8. WHERE DISSIMILAR METALS ARE TO BE JOINE�, APPROVED INSULATING UNIONS SHALL BE USED. 9. INSULATE HOT WATER LINES WITH 1" THICK SNAP ON INSULATION FIRST 8 FEET FROM WATER HEATER. 10. CONDENSATE LINES TO BE COPPER/PVC DEP�NDING ON PROJECT REQUIREMENTS. 11. INSULATE WITH 1/2" THICK ARMAFLEX INSULA FL 32233 BUILDING STRUCTURE INFORMATION CONDITIONED SPACE: EXISTING.................................................................................................1,044 S.F. ADDITION................................................................................................285 S.F. UNCONDITIONED SPACE: GARAGE.....................................................................................................312 S.F. FRONTPORCH...........................................................................................36 S.F. TOTAL: .............................................................................................................. 1,677 S.F. TYPE OF CONSTRUCTION..................................................................................5B OCCUPANCY: .................................................................................................... R-3 FIRESPRINKLERS: ............................................................................................ NO MAX HEIGHT OF STRUCTURE ................................................. ' WIND BORNE DEBRIS REGION...........................................................................NO FLOODZONE.....................................................................................................X SHEET NO. TITLE --- COVER SHEET JACKSP"NILLE ELEVATIONS A-2 EXIST./DEMO PLAN INTERNATIONAL AIR T FLOOR PLAN A-4 ROOF/ELECTRICAL PLAN DWAL STP N o FLASHING DETAILS -S-1-S-3 STRUCTURAL PLANS T RR R 4 J PS 2 � RO fp NEW CEDPR POjNT q OAD 11 iN RD yy P t 1B5 0.p �P ROAD 2 N ZN K EASTPORT DUNN AVE. ((, � p�FiL` FAVE 2 2 R Iq BUSCR R0 m i B DR_ 1 L 4• GARDEN ST ° Ap T OBLVpIV R: p CµSCNE0. DCIS 113n po 4, C SCA R -lit 4 Q ✓0608 1 Q PRITCNARD E DENFIE PO III ° � R,,e C1W FORT F S W Frele use W S. N.,y S ° T 6 2 CPROLINE RD m p� t O� Y IRVIN w O WEAt E w 24 < 90 kT � IW ARLINGTON PR 11 � J �^C(AlrpoR ^ Q2¢ BEAVER ST SWAV 1WA T� CJ � It TLANTIC ip 10 1} BLV t0 eta O YSTAI SPRINGS RO % m Y rn c6 SITE 9B �5 Fbriea Jr. Couepe (South Campus) OV tl, BEAC BLVD 11% SB Alrq,ny O�WO N N UoM Fb'C N 057 BNh e NE N BUTLER EXPRESSWAY NAS C F C. OQU 295 c 95 1 M BT n' C•cII1A, m b°°°^^^•Jacksonville BA EA N3lnatlo Q O , S BL O An 21 AbEon G a SUNBEAM At O LrN PO SALE DUVAL CO gp OF MLES v CLAY CO 13 n O KINGSLEY� T GREEN 5 BT AUGUSTINE VICINITY MAP SHEET NO. TITLE --- COVER SHEET A-1 ELEVATIONS A-2 EXIST./DEMO PLAN A-3 FLOOR PLAN A-4 ROOF/ELECTRICAL PLAN A-5 FLASHING DETAILS -S-1-S-3 STRUCTURAL PLANS OFFICE COPY U w W 0 Q �- w ASPHALT CLI LLJ SHINGLES(E) z-- - - Ln 0 O O CMU EXTERIOR t%1 BEAM HT. WALLS, TYP. (E) c�G z � p 0 V) LANDING & C? STAIRS (P) z �aoo N w 0 z o � _ z O w F.F.E (MATCH EXIST.) V) V) EXIST. GRADE O - z_ Q � ^ 0 v w J Q U V) FRONT ELEVATION 0 1/4" = V-0" z vJ C`I J z Q p J � U ASPHALT p z SHINGLES(E) Q Lu w III LLI z_ W U NEW MEMBRANE Q z w ROOFING - Z --- UrV UJ � BEAM HT. ._. — -} � — - 0 �­ MATCH U- EXIST. W U) r vJ z LJ O w z O o LANDING & U oo STAIRS (P) / w O ° U 0� F.F.E (MATCH EXIST.) ZD -1 1 1 i5�1 I x I I - _ EXIST. GRADE O �- NEW CMU < EXTERIOR U afu; WALLS, TYP. 00 0 - ASPHALT LEFT ELEVATION SHINGLES(E) ,� M 1/4" = l' -O" _ ( �� O LnLn 0 J N �z Q '_ -_ — z z - _ _ _ - -- -- _ ----- BEAM HT. (�►-� Z �-�- ^, N 1-0 } Q U Lu N M - STAIRS (P) V Q � V -_ LANDING & O _ T N o z O = �w Z� LL __ ___ _U. Lu Ln °� � F.F.E (MATCH �.., V 0U- j 1 EXIST.)n U, Q _. __ i. __ EXIST. GRADE � ,V ctfOQ ■■ ■■0 0 �z■ ■ ■ ■ 11J U NEW S.G.D. w/ v)w LANDING & STAIRS RIGHT ELEVATION Lu U m J 1/4" = 1'-0" PROJECT #: 18-304 J OQ Z J N J � DESIGNED: KCM =0 U � cn Q Lu •. O � ASPHALT DRAWN: KCM U w SHINGLES(E) SCALE: AS NOTED p0NEW zc —— MEMBRANE ISSUED: 6/25/18o ROOFING QQ Q LIJ BEAM HT. REVISION -1: �w Lu Q� 2 Z REVISION -2: Z U LANDING & CMU EXTERIOR � � STAIRS (P) WALLS, TYP. �Q44 L' z - co 0 O z N w Ly- n I v U w FEE MATCH EXIST. J w J z EXIST. GRADE 0 (-) Z Lw w -NEW S.G.D. w/ z LANDING & STAIRS C� z _ REAR ELEVATION Lu 3 1/4" = 1'-0' Z N SHEET �__z 0:�0 �z �LU A- 1 00 U w ry O U r ry w z 0 V) 0 z J z O V) z 0 V) z <w z w C� w z Q ry w J Q 0 0 U J J z w w z_ 0 z w z Q 0 w z Lu V) z 0 z Lu ry rV 0 ry 0 Q �w 0- V) 00 �Q 0V) �z z� Qo z 1-0 �U CL QO ryz oa w`) 00 =z z� w J U -' ::DQ 0>- OLL� CLLLJ> w �o 0Q o�,z w U V) w 7)= wU m J OQ zN J J � QO V)U cn Q w� Lu z UO zU O U iii z~ 012 12 N X 0 0 oCL Z a- aQ �o Qw � w w p QVD �z z0 w �w _rV �Q 3� vi 00 zN �z w Q� LY -o 0 U� J w J w z z0 _z Q!� w w w w = z 0= z� Lu Z V, �z �0 QV) �z w 00 00 12'-0j" I L 23'-11J" EXISITNG FLOOR PLAN 1/4" = 1'-0" Ln MASTER BEDROOM KITCHEN DEMOLITION PLAN 1/4" = 1'-0" 8 LIVING ROOM WALL LEDGED ►�-j EXISTING WALL TO BE REMOVED EXISITNG COMPONENTS TO BE REMOVED EXISTING TO REMAIN V) z 0 Lu z Q J 0.0 2 W D 06 CD z X Lu Ln Lu a b U J 00 os V O Ln ,-. N Z :tt M o� Z - o Lu r— N LL) W N M z r— V Q > z Oz oU LLj ineo F-• Q V) IRr Ln ■ ■ MEMOSEEN PROJECT #: 18-304 DESIGNED: KCM DRAWN: KCM SCALE: AS NOTED ISSUED: 6/25/18 REVISION -1: REVISION -2: SHEET FICE COPY I A-2 z 0 V) 0 w J Z 0 V) Z 0 N Z <w< G p Z w > (D Lu V) V) (D z_ Q ry p w J Q U V) 0 J J Z o' w w Z (D Z Lu Z rV r_ Q 0 ry w Z w V) Z 0 z w rV 0 ry o_ O Q afw 0- V) 00 �Q ON �Z �0 z� z �0 QU IL n rVQ o LLJ V, J Z 00 _V) �w z:�i wJ UJ p> - Ory D_ > w p ry OQ p�'z Lu U V) Lu wU m J I- J OQ Z= J N J ry Q =O NU vi Q Lu Z UO z0 O U di Z ~ < (3 w X p0 p� z �- QQ QLu� 11:f w wp Q N Z Z0 Lu �ry afQ V; z UO ZN —z 3 w Q2 �o p U� J w J w _Z ZU _Z 0�' w w w w= Zi (D = z_ Lu zv) �Z �0 QV) 2z r, w 00 STAIRS, LANDII PER DETAILS W N N E IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ALL BUILDING RESTRICTION LINES AND CITY ZONING REQUIREMENTS BEFORE CONSTRUCTION BEGINS. G WINDOW, SEE STAIRS, LANDINGS, GUARDS PER DETAILS & FBC R311 MODIFIED BITUMEN ROOFING OVER UNDERLAYMENT AND PLYWOOD OR OSB SHEATHING. 12 o.2sFMIN. GAL. MTL. DRIP EDGE ON 1x P.T. n OVER 2x FASCIA PLYWOOD SOFITS W/ 4"X12" SCREEN VENTS @ 48" O.C. HURRICANE TIES PER STRUCTURAL PLANS CONVENTIONAL ROOF FRAMING, SEE STRUCTURAL PLANS 2x SILL PLATE w/ ANCHORS PER STRUCTURAL SHEETS 1 COURSE CONTINUOUS BOND BEAM PER STRUCTURAL SHEETS EXTERIOR WALL COVERINGS TO MATCH EXISTING 8"x16" CMU WALL w/ VERTICAL REINF. PER STRUCTURAL SHEETS STEMWALL w/ REINF, SEE STRUCTURAL SHEET FOR SPECS. STEMWALL FOOTING ON COMPACTED SOILS,TYP. SEE ENERGY FORMS FOR INSULATION SPECS. BOND BEAM HT. (MATCH EXIST.) � 2" GYP. BOARD FASTENED TO \ CEILING PER FBC. 1X4 P.T. FIRESTOP 2" GYP. BOARD ON 1X2 P.T. FURRING @ 16" O.C. W/ R-5 PAPER BACK FOIL INSULATION. 2x FLOOR JOISTS & LEDGER LEDGER, FASTENED TO STEMWALL PER STRUCTURAL SHEETS 6 MIL VAPOR BARRIER OR EQUIVALENT WATERPROOFING IN CRAWLSPACE 1 TYPICAL WALL SECTION Scale. 1/2 – 1-0 RAILINGS/GUARDS MIN 36" HIGH W/ MAX. OPENINGS B/T GUARDS OF 4". 2x6 No. 2 SYP PT DECKING. SEE FRAMING PLAN & DETAILS. DOUBLE 2x RIM JOIST W/ BLOCKING, SEE FRAMING PLAN FOR DETAILS. FASTEN EACH STRINGER TO BEAMS W/ SIMPSON HU12 HANGERS 2x12 WOOD STRINGERS EVERY 18" O.C. FASTENED TO TREADS/RISERS W/ MIN. #10x2-1/2" WOOD SCREWS. POST FOR LANDING/STAIRWAY SUPPORTS, SEE FOUNDATION PLAN POST FTG. DETAIL. STAIR NOTES: ALL STAIRWAY SECTIONS SHALL BE A MINIMUM 36" IN WIDTH. MAXIMUM RISER HEIGHT SHALL BE 7-3/4" AND MINIMUM TREAD WIDTH SHALL BE 10 INCHES ALL FLOORS AND LANDINGS SHALL HAVE A MIN. WIDTH NO LESS THAN THE WIDTH OF THE FLIGHTS SERVED. ALL OTHER STAIR SPECIFICATIONS SHALL BE IN ACCORDANCE WITH THE 2017 FLORIDA BUILDING CODE, R317. TE CONCRETE SLAB W/ is" X 3" TAPCON SCREWS EVERY 12" O.C.(CONC. ONLY) Z TYPICAL STAIR DETAIL Scale: 1/2" = 1'-0" OFFICE COPY Z Q 0 0 J LL V z L.LJ LL) z V z L1..1 w I— Q z 00 M C:) Ln N 4t 0-4 zLL. M .--- W o� Q> Oz �O LLIV) <a V) n O Ln � I O,% N Ln N d- 0 N ' M N �Q 0 V au - ■ ■ ■ ■ ■ ■ ■ ■ PROJECT #: 18-304 DESIGNED: KCM DRAWN: KCM SCALE: AS NOTED ISSUED: 6/25/18 REVISION -1: REVISION -2: SHEET A-3 I- U Lu Lu u Q w U-1 z 3NEW ROOF AREA ° z N GSI O o O _ a E V t v) z C) I oW z---------- / o — — z — I \ 1 I w XF/LLj_j A-4 N / / \ \ 0 0.25/12 I 3-4/12 3-4/12 — — — — Q (MIN.) U V) MEMBRANE 0 ROOFING _ I Q LL o U r U zN �Q U.J I G7 L.L w / �... Z W r\ I SEE FLASHING ( I HOWER GF,I w DETAILS FOR I O O D U ~ MATCH WATERPROOFINGFI O EXIST. W W U) - �' o REF. \ V J z Lu V) _ RANGE/EXT. EXHAUST HOOD �\ 11. Q OU A/C DISCONNECT GF _ — i L z Lu 0 3-4/12 O I / I iA- 0 \ X L.L CL 3-4/12 \ Q I ' LLj �w Q G F4 0M�00p0 O~ � FI I r----------- p'�0oIN, 0 N O I i I% z M zQ �- I I i LnN z0-4 o I / ` I zu.. d'O �o/ j I I M � M z I I z �-� 0 Q / JZ V Qv ---- - Ohz o °° 3w z w �'O �`u Z :�i 0 o I PROPOSED ELECTRICAL PLAN Z HLLJ J 1/4• _ 1'-0' 0 � (� V) w w � Q OLn \I OQ ■■ NONE Lu U � w TPO MEMBRANE STRIP Lu J ROOF PLAN AD METAL DRIP ELECTRICAL LEGEND1/4" i -o" O EDGE, MECHANICALLY ATTACH PROJECT #:= 18-304 N STAGGERED 3OC J 0/ HEAT WELD TPO MEMBRANE DESIGNED: U SHEET METAL GUTTER CEILING FAN ® EYEBALL LIGHT KCM V) Q W MECHANICALLY ATTACH RECESSED LIGHT U O DRAWN: KCM 6" O.C. Z O U WOOD NAILER FLOURESCENT LIGHT SCONCE U Lid NEW ROOF DATA LIGHT F/L PRE–WIRE & BRACE SCALE: AS NOTED Z Q TPO MEMBRANE /� 17 Lu XO (LINEAR FT.) SPECIFIED ADHESIVE �J DOOR BELL (LOW VOLTAGE) cef OUTLET q ISSUED: 6/25/18 Q Q z OL CABLE LINE 40' GFI GROUND FAULT INTERRUPT REVISION -1: w (All Waterproof) SMOKE DETECTOR/CARBON MONOXIDE N GABLE LME N A D O AFI ARC FAULT INTERRUPT FLOOD LIGHT REVISION -2: z LLJ RIDGE L- NE N/A ROOF DECKS PENDANT LIGHT GARBAGE DISPOSAL Yp 3 10 HIP NE N A TAPERED INSULATION (WHERE N z SPECIFIED) I'_0 WALL MOUNTED LIGHT � I AUTOMATIC GARAGE DOOR D O GJTTER SPACER 36" O.C. Z z U A L L- E Y N E N/ A S�11GGERED ALTERNATELY BUTTON & SENSORS (LOW VOLTAGE) Q < < �( 9") WITH BRACKETS ® EXHAUST FAN/LIGHT Elf GUTTER BRACKET 36" O.C. S.F. ® COMP. COMPRESSOR w UROOF- AREA 347 S.F. FAN ONLY J w J z NOTE: 0 1. ALL METAL SURFACES SHALL BE PRIMED BEFORE CONTACT WITH 4NY ADHESIVE OR MASTIC. SWITCH z z 0!� w zUj NOTE: $3 THREEWAY z� -HE ABOVE ROOF DATA DOES NOT INCLUDE ROOF PITCH FACTORS & � ROOFING & EDGE D -TAIL OFFICE CQ„ SHEET Lu CONSTRUCTION WASTE. ALL PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL COMPLY WITH Z v) z THE MINIMUM REQUIREMENTS FOR HIGH–EFFICACY LAMPS PER Q 0 FBC–ENERGY CONSERVATION R404. A-4 CV � -J z 0 O U- J Z 0 z 0 Ln Z w 0 z Lu > 0 Lu V) V) C� Z Q Lu J V) 0 0 0 J J z rV w Lu Z z Lu z ryry Li 0 Z Lu V) Z 0 Z Lu 0 ctf CL 0 3 Q � Li LL -V) 00 ryQ OZ 0 >-o Z �_ Q� Z Z �0 QQ r)"Z ON Lu 00 3Lu z� 00 UQ n>- OrV 0�f CL > Lu � Z OQ LuU V) w Lu U m J F- J OQ Z= J ry QO NU �Q �CZ w �_- UZ z OU Uz z Q 9 _�E N X 00 �0- Z 0- < < QQ �0 �w Lu Q�75 :�i Z z0 Lu U w oL o= Q 3Z z O Z � � 0� U� J w J Z Zz z O:f w Lu w w z� Z~ w Z V, �z QO �z LU 00 GENERAL STRUCTURAL NOTES THE CONTRACTOR SHALL✓ERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOBSITE PRIOR TO COMMENCING WORK. CONTRACTOR SHELL REPORT ALL DISCREPANCIES THE DRAWINGS AND EXISTING CONDITION TO THE ENGINEER PRIOR TO COMMENCING WORK. DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE TYPICAL AND APPLY TO SIMILAR SITUATIONS ELSEWHERE, EXCEPT AS OTHERWISE INDICATED. ADAPT REQUIREMENTS OF DETAILS, SECTIONS, PLANS, AND NOTES AT LOCATIONS WHERE CONDITIONS ARE SIMILAR. DIMENSIONS INDICATED ON THE DRAWINGS IN REFERENCE TO EXISTING CONDITIONS ARE THE BEST AVAILABLE DATE OBTAINABLE, BUT ARE NOT GUARANTEED. BEFORE PROCEEDING WITH ANY WORK DEPENDENT ON THE DATA INVOLVED, THE CONTRACTOR SHALL FIELD CHECK AND VERIFY ALL DIMENSIONS, GRADES, LINES, LEVELS, OR OTHER CONDITIONS OF LIMITATIONS AT THE SITE TO AVOID CONSTRUCTION ERRORS. IF ANY WORK IS PERFORMED BY THE CONTRACTOR OR ANY OF HIS SUBCONTRACTORS PRIOR TO ADEQUATE VERIFICATION OF APPLICABLE DATA, AT RESULTANT EXTRA COST FOR ADJUSTMENT OR WORK AS REQUIRED TO CONFORM TO EXISTING LIMITATIONS, SHALL BE ASSUMED BY THE CONTRACTOR WITHOUT REIMBURSEMENT OR COMPENSATION BY THE OWNER. CENTER ALL FOOTINGS AND PIERS UNDER COLUMNS ABOVE UNLESS SPECIFICALLY DIMENSIONED OTHERWISE. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SITE DRAWINGS. CONSULT THESE DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS, CONTRACTOR SHALL LOCATE ALL BURIED UTILITIES PRIOR TO EXCAVATION FOR BUILDING FOUNDATIONS. THE STRUCTURAL ENGINEER SHALL BE NOTIFIED OF POTENTIAL CONFLICTS BETWEEN FOUNDATIONS AND BURIED UTILITIES. CODE REQUIREMENTS: THE BUILDING STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE 2017 EDITION OF THE FLORIDA BUILDING CODE 6TH EDITION. OTHER CODES IMPLEMENTED FOR DESIGN INCLUDE: ASCE7-10, ACI 315/318/530, NDS 2015, APA, A.I.S.C., ANSI. FOLLOW ALL APPLICABLE PROVISIONS OF THE FLORIDA BUILDING CODE AND OTHER RELATED CODES FOR ALL PHASES OF CONSTRUCTION. TEMPORARY CONDITIONS: THE STRUCTURAL INTEGRITY OF THE COMPLETED STRUCTURE DEPENDS ON INTERACTION OF VARIOUS CONNECTED COMPONENTS. PROVIDE ADEQUATE BRACING, SHORING, AND OTHER TEMPORARY SUPPORTS AS REQUIRED TO SAFELY COMPLETE THE WORK. THE STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR STABILITY UNDER FINAL CONFIGURATION ONLY. FOUNDATIONS: FOUNDATIONS ARE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PSF ON COMPACTED FILL. NO GEOTECHNICAL REPORTS AND/OR IN-SITU SOIL DATA WAS GIVEN TO THE STRUCTURAL ENGINEER PRIOR TO DESIGN. THE BEARING CAPACITY USED FOR DESIGN IS BASED ON ALLOWABLE LOADS FROM THE FLORIDA BUILDING CODE, 2017 FOR SANDY SOILS WITH NO CLAY, ORGANIC MATERIAL, OR OTHER DELETERIOUS MATERIALS THAT WOULD AFFECT DESIGN BEARING PRESSURE AND THE PERFORMANCE OF THE FOUNDATIONS. BEFORE CONSTRUCTION COMMENCES, SOIL BEARING CAPACITY SHALL BE VERIFIED BY A SUBSURFACE INVESTIGATION,AS WELL AS FIELD AND LABORATORY TESTS PERFORMED BY A CERTIFIED TESTING LABORATORY, WHOSE REPORT SHALL INCLUDE ANALYSIS AND RECOMMENDATIONS FOR SITE PREPARATION IN ORDER TO BEAR THE FOUNDATION LOADS. ABOVE REPORT SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW BEFORE FOUNDATION CONSTRUCTION BEGINS. CONCRETE: REINFORCED CONCRETE CONSTRUCTION SHALL CONFORM TO THE FBC AND ACI 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE". CONCRETE STRENGTHS SHALL BE VERIFIED BY STANDARD 28 -DAY CYLINDER TESTS PER ASTM C39, AND SHALL BE AS FOLLOWS: fc ABS W/C MIN CEMENTSLUMP USE 2,500 PSI 0.58 470 LBS 5" +/- 1 ALL SLABS, MONOLITHIC FOOTINGS, SPREAD FTG 3,000 PSI 0.58 470 LBS 5" +/- 1 TIEBEAMS, COLUMNS, WALLS, ELEVATED SLABS CEMENT SHALL CONFORM TO ASTM C150, TYPE 1. FLY ASH CONFORMING TO ASTM C618, TYPE FOR TYPE C, MAY BE USED TO REPLACE UP TO 20% OF THE CEMENT CONTENT, PROVIDED THAT THE MIX STRENGTH IS SUBSTANTIATED BY TEST DATA. COARSE AGGREGATE SHALL CONFORM TO ASTM C33 WITH A MAXIMUM SIZE OF 3/4". FINE AGGREGATE SHALL BE CLEAN, DURABLE, NATURAL SAND CONFORMING TO ASTM C33. A WATER -REDUCING ADMIXTURE CONFORMING TO ASTM C494, USED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, SHALL BE INCORPORATED IN CONCRETE DESIGN MIXES. A HIGH -RANGE WATER -REDUCING ADMIXTURE CONFORMING TO ASTM C494, TYPE F OR G, MAY BE USED IN CONCRETE MIXES, PROVIDING THAT THE SLUMP DOES NOT EXCEED 8". SLEEVES, OPENINGS, CONDUIT, AND OTHER EMBEDDED ITEMS NOT SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE APPROVED BY THE STRUCTURAL ENGINEER BEFORE POURING. NO SLEEVE, OPENING, OR INSERT MAY BE PLACED IN BEAMS, JOISTS, OR COLUMNS UNLESS APPROVED BY THE ENGINEER. CONDUITS EMBEDDED IN SLABS SHALL NOT BE LARGER IN OUTSIDE DIMENSION THAN ONE THIRD OF THE THICKNESS OF THE SLAB AND SHALL NOT BE SPACED CLOSER THAN THREE DIAMETERS ON CENTER. PROVIDE 3/4" CHAMFERS ON ALL EXPOSED CONCRETE EDGES, UNLESS NOTED OTHERWISE. WHERE INDICATED OR REQUIRED, SLOPE CONCRETE SLABS TO DRAINS SHOWN ON PLUMBING AND/OR ARCHITECTURAL DRAWINGS. ALL CONCRETE SHALL BE CURED IMMEDIATELY AFTER FINISHING OPERATIONS. WEATHER RESISTANCE: ALL CONCRETE INCLUDING BALCONY CONCRETE EXPOSED TO CHLORIDES SHALL CONTAIN A CALCIUM -NITRITE BASED CORROSION -INHIBITING ADMIXTURE. THE DOSAGE FOR CONCRETE EXPOSED TO AIRBORNE CHLORIDES SHALL BE MINIMUM TWO GALLONS PER CUBIC YARD. THE WATER CONTAINED IN THE CORROSION -INHIBITING ADMIXTURE SHALL BE USED IN THE CALCULATION OF THE WATER-TO-CEMENTITIOUS RATIO OF THE CONCRETE. PROVIDE RHEOCRETE CNI BY MASTER BUILDERS OR APPROVED EQUIVALENT. CONCRETE BALCONIES OR OTHER CONCRETE FLAT SURFACES EXPOSED TO THE WEATHER THROUGHOUT THE LIFE OF THE BUILDING, SHALL BE TREATED WITH A CLEAR NONFLAMMABLE PENETRATING SEALER OF THE ALKYL_ALKOXY SILANE CLASSIFICATION, SUCH AS SONNEBORN PENETRATING SEALER 20, HYDROZO ENVIROSEAL 20, OR OTHER APPROVED WEATHER RESISTANT SYSTEM, APPLICATION AND SURFACE PREPARATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. SHORING AND RESHORING: SHORING AND RESHORING SHALL CONFORM TO ACI 347R-88. SHORING AND SUPPORTING FORMWORK SHALL NOT BE REMOVED FROM HORIZONTAL MEMBERS BEFORE CONCRETE STRENGTH IS AT LEAST 70 PERCENT OF DESIGN STRENGTH, AS DETERMINED BY FIELD CURE CYLINDERS. IN ADDITION, SHORING SHALL NOT BE REMOVED SOONER THAN RECOMMENDED BY ACI 347R-88, SECTION 3.7.2.3. FORMWORK SHALL NOT BE REMOVED IN LESS THAN TEN (10) DAYS. PRECAST CONCRETE LINTELS: UNLESS INDICATED OTHERWISE, ALL LINTELS TO BE "U" TYPE PRECAST CONCRETE UNITS EQUAL TO UNITS MANUFACTURED BY CAST CRETE CORP. AND PRESTRESSED (AND ADDITIONALLY REINFORCED AS REQUIRED) IN ACCORDANCE WITH CAST CRETE CORP. "DESIGN MANUAL", LATEST EDITION, FOR THE SPAN AND LOADING CONDITION RELATIVE TO LINTEL LOCATION. LINTEL SIZE IF NOT SHOWN ON THE PLANS SHALL BE 8F8•113 FOR OPENINGS LESS THAN 10 FEET AND 8F16-1 B/1T FOR OPENINGS 10 FEET TO 20 FEET. PROVIDE 8" MINIMUM BEARING FOR LINTELS UNLESS NOTED OTHERWISE. WOOD: SAWN LUMBER SHALL BE SOUTHERN PINE #2 WITH THE ALLOWABLE FIBER STRESSES PER THE AWC NATIONAL DESIGN SPECIFICATION. ALL MANUFACTURED LUMBER SHALL BE 2.0E GLUED LAMINATED GEORGIA PACIFIC (OR EQUIV.) AND INSTALLED ACCORDING TO MANUFACTURES RECOMMENDATIONS. ALL HEADERS/BEAMS SHOULD BEAR FULLY ON POSTS AND/OR MULTI STUD GROUPS UNLESS NOTED OTHERWISE ON PLANS. CONTACT ENGINEER OF RECORD IF HEADER/BEAMS SIZE IS NOT SPECIFIED. FRAMING ACCESSORIES AND STRUCTURAL FASTENERS SHALL BE MANUFACTURED BY SIMPSON COMPANY OR USP (OR APPROVED EQUAL) AND OF THE SIZE AND TYPE SHOWN ON THE DRAWINGS. HANGERS NOT SHOWN SHALL BE SIMPSON HU OF SIZE RECOMMENDED FOR MEMBER. ALL CONNECTORS SHALL BE GALVANIZED. UNLESS SHOWN OTHERWISE, INSTALL MAXIMUM SIZE AND NUMBER OF FASTENERS SHOWN IN LATEST SIMPSON CATALOG ALL FRAMING NAILS SHALL BE COMMON NAILS AND SHALL BE OF THE SIZE AND NUMBER INDICATED ON THE DRAWINGS. MINIMUM NAILING REQ. NOT SHOWN SHALL BE AS INDICATED IN TABLE 2304.9.1 OF THE FBC. INSTALL 1 Od NAILS UNLESS OTHERWISE SPECIFIED ON THE PLANS OR DETAILS. BOLTS AND LAG SCREWS SHALL CONFORM TO ANSI/ASME STANDARD 818.1. ALL BOLTS AND LAG SCREWS SHALL BE INSTALLED WITH STANDARD CUT WASHERS. ALL ANCHOR BOLTS AND THREADED ANCHOR RODS SHALL BE IN ACCORDANCE WITH ASTM A307, GRADE A, OR ASTM F1554, GRADE 36. ANCHOR ADHESIVES SHALL BE EITHER SET (EPDXY-TIE) OR AT (ARCYLIC-TIE) BY SIMPSON STRONG -TIE AND INSTALLED ACCORDING TO THE MANUFACTURES INSTRUCTIONS. ALL DRILLED ANCHOR HOLES SHALL BE CLEANED OF ALL DEBRIS AND BRUSHED OUT PRIOR TO INSTALLATION OF ANCHOR ADHESIVE. ALL WOOD MEMBERS EXPOSED TO EXTERIOR CONCRETE, MASONRY, WEATHER, OR EARTH SHALL BE PRESSURE TREATED LUMBER. ALL NAILS DIRECTLY EXPOSED TO WEATHER SHALL BE GALVANIZED. FASTENER REQUIREMENTS IN PRESSURE TREATED LUMBER ARE AS FOLLOWS: ACZA PRESERVATIVE: STANDARD CARBON STEEL. ACQ & MCQ PRESERVATIVE: HOT DIPPED GALVANIZED, SODIUM BORATE: STAINLESS STEEL CONNECTORS & FASTENERS (NOT REQ. FOR SILL PLATES OVER CONCR. & VAPOR BARRIER NOT DIRECTLY EXPOSED TO EARTH OR WEATHER) ALL DECKS, GUARDS, RAILS, STAIRS AND OTHER ACCESSORY DECK COMPONENTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH AWC DCA6 PRESCRIPTIVE GUIDE FOR DECK CONSTRUCTION & THE FLORIDA BUILDING CODE, 2017. ALL FASTENERS AND CONNECTORS EXPOSED TO SALT WATER OR LOCATED WITHIN 300 FEET OFA SALT WATER SHORE LINE SHALL BE STAINLESS STEEL GRADE 304 OR 316 ALL EXTERIOR WOOD WALLS WITHOUT OPENINGS SHALL BE CONSIDERED SHEAR WALLS. ALL WOOD DESIGN SHALL BE IN ACCORDANCE WITH THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, 2015 & WITH THE FLORIDA BUILDING CODE, 2017. PLYWOOD PAk:_LS SHALL CONFORM TO THE REQUIREMENTS OF"U. . PRODUCT STANDARD PS -1 FOR CONSTRUCTICI I AND INDUSTRIAL PLYWOOD" OR APA PRP -108 PERF RMANCE STANDARDS. UNLESS OTHERWISE NOTED, PANED SHALL BE APA RATED SHEATHING, EXPOSURE 1, OF THE THICKNESS AND SPAN RATING SHOWN ON THE DRAWINGS. PLYWOOD INSTALLATION SHALL BE IN CONFORMANCE WITH APA RECOMMENDATIONS. ALLOW 1/8" SPACING AT PANEL EDGES, UNLESS OTHERWISE RECOMMENDED BY THE PANEL MANUFACTURER. ALL SUB -FLOORING, ROOF, AND SHEARWALL SHEATHING SHALL BEI STALLED WITH FACE GRAIN PERPENDICULAR TO SUPPORTS, EXCEPT AS INDICATED ON THE DRAWINGS. STAGGER ENDS OF ADJACENT PANELS 4' ROOF SHEATHING SHALL BE BLOCKED, TONGUE -AND -GROOVE, OR HVE EDGES SUPPORTED BY PLYCLIPS. ATTACH PLYWOOD PANELS TO SUPPORTING MEMBERS WITH 10d NAII S SPACED 4" ON CENTER ALONG THE PANEL EDGES AND AT 6" ON CENTER ALONG INTERMEDIATE SUPPORTS, UNLESS NOTED OTHERWISE. SUB -FLOORING SHEATHING SHALL BE UNBLOCKED, EXCEPT AS INDICATED ON DRAWINGS. ATTACH PLYWOOD PANELS TO SUPPORTING MEMBERS WITH 8d NAILS SPACED 4" ON CENTER ALONG THE PANEL EDGES AND AT 8" ON CENTER ALONG INTERMEDIATE SUPPORTS, UNLESS NOTED OTHERWISE. PREFABRICATED WOOD TRUSSES: SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGN INTENT OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC. CONTRACTOR SHALL NOT BE RELIEVED FROM RESPONSIBILITY FOR ERRORS OR OMISSIONS IN SH P DRAWINGS OR MIX DESIGNS BY THE ENGINEER'S REVIEW. DESIGN AND MANUFACTURE IN ACCORDANCE WITH TPI "DESIGN SPECIFICATIONS FOR METAL PLATE CONNECTED WOOD TRUSSES", LATEST EDITION. ROOF TRUSS LOADING: SEE TRUSS MANUFACTURES SIGNED AND SEL TRUSS SHOP DRAWINGS FOR APPLICABLE TRUSS DESIGN LOADS. TRUSS LOADINGS SHALL BE BASED ON THE P OJECTS DESIGN LOADS AND THE MINIMUM LOAD REQUIREMENTS SET FORTH BY ASCE 7-10 AND THE FLORIDA BUILDING CODE, 2017 RESIDENTIAL. ALL TRUSS TO TRUSS CONNECTIONS TO BE DESIGNED BY TRUSS MANUFACTURER AND MADE USING TRUSS HANGERS. TRUSS DIAGRAMS, IF SHOWN, ARE DIAGRAMMATIC ONLY. TRUSS DESIGNER TO DETERMINE AND ESTABLISH EXACT HEIGHT, LENGTH, LOCATION, SPACING, AND WEB N EMBER FOR EACH TRUSS. COORDINATE WITH ARCHITECTURAL AND MECHANICAL DRAWINGS FOR ADDITIONAL ITEMS INCLUDING AIR HANDLER LOCATIONS, MECHANICAL ROOMS AND DUCT SPACE AND ROUTING. BUILDER SHALL COORDINATE WITH TRUSS DESIGNER FOR PERMANE T TRUSS BRACING. IF NO BRACING INFORMATION IS PROVIDED, BOTTOM CHORD LATERAL BRACING SHA L BE CONTINUOUS FROM ONE END OF THE BUILDING TO THE OTHER AND SHOULD OVERLAP AT LEAST ONE TRU S SPACE FOR CONTINUITY. LATERAL BRACING SHALL BE NAILED TO EACH TRUSS WITH A MIN. OF (2) 16d N ILS INCLUDING INTERMEDIATE TRUSSES. SEE TRUSS SHOP DRAWINGS FOR OTHER DETAILS AND SPECIFICATI NS FOR BRACING. REINFORCING STEEL: REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, FOR DEFORMED BAR AND ASTM A185 FOR SMOOTH WELDED WIRE FABRIC (WWF), UNLESS OTHERWISE NOTED. REINFORCING STEEL TO BE WELDED SHALL CONFORM TO ASTM A706. REINFORCING STEEL SHALL BE SECURELY TIED IN PLACE WITH #16 ANNEALED IRON WIRE. ALL DETAILING AND ACCESSORIES SHALL CONFORM TO ACI DETAILINMANUAL SP 66, PROVIDE CHAIRS, SPACERS, BOLSTERS, AND ITEMS IN CONTACT WITH FORMS WITH HO _DIP GALVANIZED LEGS OR PLASTIC LEGS, ACCURATELY POSITION, SUPPORT, AND SECURE REINFORCEMENT A 'AINST DISPLACEMENT BY FORMWORK CONSTRUCTION OR CONCRETE PLACEMENT OPERATIONS. "WET -STI 'KING" OF REINFORCING IS PROHIBITED. REQUIRED CONCRETE COVER FOR REINFORCING STEEL (UNLESS NO ED OTHERWISE): FOOTINGS 3" BOTTOM AND SIDES, 2" TOP SLABS 3/4" COLUMNS 1-1/2" TO TIES, 2" TOP BEAMS 1-1/2" TO STIRRUPS WALLS 1-1/2" LAP SPLICE CONTINUOUS VERTICAL OR HORIZONTAL BARSIN CONCRETE MEMBERS IN ACCORDANCE WITH ACI 318, LATEST EDITION, FOR CLASS "B" TENSION LAP SPLICES. DO NOT 3PLICE CONTINUOUS TOP BARS IN BEAMS AT ENDS OF CLEAR SPANS. DO NOT SPLICE CONTINUOUS BOTTOM BARS IN BEAMS IN CLEAR SPANS BETWEEN SUPPORTS, SHOW ALL SPLICES ON SHOP DRAWINGS. SPLICE LOCAT ONS AND METHODS SUBJECT TO APPROVAL OF STRUCTURAL ENGINEER. AT SLAB AND WALL OPENINGS PROVIDE A MINIMUM OF (2) #5 BARS AL _ FOUR SIDES AND DIAGONALLY; EXTEND THESE BARS A LAP DISTANCE OR A MINIMUM OF 24" PAST THE OPENI G OR HOOK BARS IF DISCONTINUOUS. DOWEL ALL WALLS AND COLUMNS TO FOOTINGS WITH BAR SIZE AND PACING TO MATCH VERTICAL REINFORCING UNLESS OTHERWISE SHOWN, MASONRY WALLS: MASONRY UNITS SHALL MEET ASTM C90, TYPE 2. ASSEMBLIES SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF fm= 1500. MORTAR SHALL BE TYPE "M" OR "S" AND MEET ASTM C2 '0. GROUT SHALL BE 2000 PSI MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS IN ACCORDANCE WITH ASTM C 76. GROUT SHALL CONSIST OF A MIXTURE OF CEMENTITIOUS MATERIALS AND AGGREGATE TO WHICH SUFFICIENT WATER HAS BEEN ADDED TO CAUSE THE MIXTURE TO FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. GROUT SHALL HAVE A MAX. COURSE AGGR. SIZE OF $" & SHALL BE PLACE WITH A SLUMP OF 8 TO 11 INCHES. ALL ELLS CONTAINING VERTICAL BARS, BOND BEAMS, AND ALL CELLS BELOW GRADE SHALL BE FILLED WITH GROUT. MAXIMUM HEIGHT OF GROUT POUR ALLOWED IS 5-0" UNLESS CLEAN-OUT OPENING IS PROVIDED AT BOTTOM OF CELLS TO BE FILLED. LOCATE CLEAN-OUT OPENINGS IN AREAS NOT EXPOSED TO VIEW. CLEAN OUT OPENINGS SHALL HAVE A MIN, OPENING DIMENSION OF 3 INCHES. UNLESS NOTED OTHERWISE EIGHT INCH MASONRY WALLS SHALL BE �IARTIALLY REINFORCED MASONRY WALL CONSTRUCTION WITH #5 AT 48 INCH O.C. IN GROUT FILLED CELLS. ADD (1) #5 REINFORCING BAR EACH SIDE OF OPENINGS EXCEEDING 3 FEET. PROVIDE REINFORCING BARS AT CORNERS, INTERSECTIONS, AND EA H SIDE OF OPENINGS. PROVIDE (2) REINFORCING BARS EACH SIDE OF OPENINGS OVER 4 FEET WIDE, AND AS SHOWN ON THE PLANS. PROVIDE HOOKED DOWELS INTO FOOTINGS AND STRUCTURE ABOVE AND/OR BELOW TO PROVIDE CONTINUITY. PROVIDE 9 GAGE GALVANIZED HORIZONTAL JOINT REINf ORCING (DUR-O-WAL OR ENGINEER -APPROVED EQUAL) AT 16" O.C. DO NOT PLACE CONDUITS, PIPES, ETC., IN CELLS WITH VERTICAL REINFORCING. DO NOT RUN CONDUITS, PIPES, ETC., HORIZONTALLY IN CMU WALLS PARALLEL TO LENGTH OF WALL. WHERE MASONRY WALLS ABUT CONCRETE COLUMNS TO BE PLACED PRIOR TO ERECTION OF MASONRY WALLS, PROVIDE DOVETAIL SLOTS BETWEEN COLUMN AND WALLS AND GROUT THE CMU CELL CONTAINING THE DOVETAIL ANCHORS. OTHERWISE, EXTEND CMU HORIZONTAL JOINT REINFORCING THROUGH CONCRETE COLUMN. CONTROL JOINTS SHALL BE PROVIDED IN ALL CONCRETE MASONRY C NSTRUCTION AT LOCATIONS INDICATED ON THE ARCHITECTURAL DRAWINGS. HORIZONTAL WALL REINFORCING SHALL BE STOPPED EACH SIDE OF CONTROL JOINTS. SEE ARCHITECTURAL DRAWINGS FOR SEALANT REQUIREME IS AT CONTROL JOINTS. USE METAL LATH OR WIRE SCREEN FOR CAVITY CAPS. SHEET METAL, FELT, BUILDING PAPER, OR LIKE MATERIALS ARE PROHIBITED. CHEMICAL ADHESIVE ANCHORING IN HOLLOW CELL APPLICATIONS ADHESIVE ANCHORS (EPDXY STYLE) SHALL BE USED IN HOLLOW CMU APPLICATIONS FOR STRUCTURAL ANCHORING. ANCHORS SHALL BE TESTED TO ASTM E488 AND ICBO A 58. ICBO AND/OR SBCCI CODE COMPLIANCE IS REQUIRED IN APPROPRIATE AREAS. METRO-DADE COMPLIANCE AN /OR FLORIDA BUILDING CODE COMPLIANCE ARE REQUIRED IN FLORIDA. ANCHORING SYSTEM SHALL INCLUDE THE ADHESIVE, MESH SCREEN (OR UMBRELLA), ANCHOR (OR INSERT) AND WASHER/NUT FOR PROPER ANCHORING. ACCEPTED PRODUCTS ARE ITW RED HEAD ACRYLIC 7, GRANITE 5 OR ENGINEER APPROVED SUBSTITUTION. ADHESIVE SHALL BE MOISTURE INSENSITIVE (ALLOWING INSTALL ATIO SIN DAMP OR WATER -FILLED HOLES). ADHESIVE SHALL HAVE A FULL -CURE LOAD OF 2 HOURS OR LESS AT 7 °F OR SAFETY ISSUES. MESH SCREENS SHALL BE FORMED INTO A CYLINDRICAL SHAPE WITH NE END CLOSED. ALTERNATELY, UMBRELLA SUPPLIED BY ITW REDHEAD MAYBE USED IN APPROPRIAT APPLICATIONS. THREADED STUDS SHALL CONFORM TO ASTM A36 (STANDARD CARBON STEEL) UNLESS NOTED OTHERWISE. PERMANENTLY EXPOSED STUDS SHALL BE STAINLESS STEEL. NUTS AND WASHERS SHALL CON ORM TO THE SAME SPECIFICATION AS THE SUPPLIED STUD. INSTALLATION SHALL BE IN CONFORMANCE WITH MANUFACTURER'S PRINTED LITERATURE. INSTALLATION SHALL ALSO INCLUDE BRUSHING AND CLEANING OF DRILLED HOLES WITH COMPRESSED AIR AS INSTRUCTED. INSTALLERS SHALL BE TRAINED BY THE MANUFACTURER'S REPRESENTATIVE. EMBEDMENT SHALL BE AS INDICATED ON THE STRUCTURAL DRAWINGS. DESIGN CRITERIA: DESIGN WAS BASED ON STRENGTH AND DEFLECTION CRITERIA OF THE 2017 FLORIDA BUILDING CODE 6TH EDITION. IN ADDITION TO THE DEAD LOADS, THE FOLLOWING LOADS AND ALLOWABLES WERE USED FOR DESIGN, WITH LIVE LOADS REDUCED PER THE 2017 FBC: a �a a m I V BM I BEAM B/T 1 BETWEEN CONN. 1 CONNECTION CONT. 1 CONTINUOUS CL CENTER LINE CLG CEILING a ABBREVIATIONS CMU CONCRETE MASONRY UNIT V V L/360 - L/240 L/360 - L/240 L/240 - BRITTLE L/180 - FLEXIBLE WIND PRESSURES ON WALLS & ROOFS s EFFECTIVE AREA OF LIVE LOAD DEAD LOAD ROOF: 20 PSF 15 PSF FLOORS: 40 PSF 15 PSF DECKS: 50 PSF 15 PSF WALLS: PER C&C PER ASCE?-10 -100.2 BELOW TELE. C3-1 ULTIMATE WIND SPEED -57.0 130 MPH PER ASCE 7-10 NOMINAL WIND SPEED: -37.8 101 MPH PER FBC R301.2.1.3 EXPOSURE 22.4 C PER ASCE 7-10 IMPORTANCE FACTOR -44.2 1.0 CATEGORY II INTERNAL PRESSURE COEFF +/-0.18 ENCLOSED (PROTECTED OPENINGS) COMPONENTS & CLADDING PRESSURES PER TABLE & CHARTS ON THIS PAGE. a �a a m I V BM I BEAM B/T 1 BETWEEN CONN. 1 CONNECTION CONT. 1 CONTINUOUS CL CENTER LINE CLG CEILING a ABBREVIATIONS CMU CONCRETE MASONRY UNIT V V L/360 - L/240 L/360 - L/240 L/240 - BRITTLE L/180 - FLEXIBLE WIND PRESSURES ON WALLS & ROOFS s EFFECTIVE AREA OF ROOF ZONES' EXTERIOR WALLS' OPENING/ROOF ZONE2 INTERIOR ZONE 1 EDGE ZONE 2 CORNER ZONE 3 INTERIOR ZONE 4 END ZONE 5 0 to 10 24.5 -38.9 24.5 -67.8 24.5 -100.2 42.6 -46.2 42.6 -57.0 10.1 to 20 22.4 -37.8 22.4 -62.4 22.4 -93.8 40.6 -44.2 40.6 -53.2 20.1 to 50 19.5 -36.4 19.5 -55.2 19.5 -85.138.1 PSF -41.7 38.1 -48.0 50.1 to 100 17.4 -35.3 17.4 -49.8 17.4 -73.1 36.3 -39.8 36.3 -44.2 100.1 to 500 - - - - - - 31.8 -35.3 31.8 1.--35-31 WITHOUT 1. WIND PRESSURES SHOWN ABOVE ARE FOR STRUCTURES WITH A MEAN ROOF HEIGHT OF 30 FEET OR LESS WITH A ROOF PITCH BETWEEN 2/12 & 6/12 (VERT./HORIZ.). IF THE STRUCTURE IS OUTSIDE THESE PARAMETER PLEASE CONTACT THE ENGINEER. 2. THE EFFECTIVE AREA IS EQUAL TO THE LENGTH " WIDTH OF THE PROPOSED OPENING OR SPAN. THE WIDTH SHALL BE PERMITTED TO BE NOT LESS THAN 3 OF THE SPAN LENGTH. THE EFFECTIVE AREA FOR FASTENERS SHALL NOT BE GREATER THAN THE TRIBUTARY AREA B/T FASTENERS. 3. ALL WIND PRESSURE VALUES IN POUNDS PER SQ. FT(PSF) & ARE CONSIDERED ULTIMATE VALUES. MULTIPLY VALUES BY 0.6 FOR NOMINAL PRESSURES PER FBC R301.2.1.6 ZONE CHARTS �a a I - T�o o�-------- o ---- Ol O �O O-------- O -------- 3� 2 2 O I O ca - - a GABLE ROOFS DL DEAD LOAD EOR ENGINEER OF RECORD EXT. EXTERIOR FBC FLORIDA BUILDING CODE (2017, 6TH EDITION) FFE FINISHED FLOOR ELEVATION FTG FOOTING FPA FLORIDA PRODUCT APPROVAL INT. INTERIOR LG LENGTH LL LIVE LOAD LVL LAMINATED VENEER LUMBER (2.OE, 14 WIDE MIN. U.N.O.) MAX. MAXIMUM MIN. MINIMUM OR "OR" MEANS THAT EITHER OPTION PROVIDED IS SUFFICE FOR THE APPLICATION O.C. ON CENTER SPACING OPT OPTIONAL OSB ORIENTED STAND BOARD (APA RATED MIN.) PCF POUNDS PER SQUARE FEET PLYW. PLYWOOD (APA RATED MIN.) PSF POUNDS PER SQUARE FEET PSI POUNDS PER SQUARE INCH SS STAINLESS STEEL STAGG. STAGGERED SPF SPRUCE -PINE -FIR SYP SOUTHERN YELLOW PINE (No. 2 MIN.) SW SHEAR WALL T/G TOGETHER T&G TONGUE AND GROOVE TYP TYPICAL U.N.O. UNLESS OTHERWISE NOTED W/ WITH w/o WITHOUT W.W.M/F WELDED WIRE MESH OR FABRIC WALLS SHEETINDEX S-1 STRUCTURAL NOTES & SPECIFICATIONS S-2 FOUNDATION & FRAMING PLAN S-3 ROOF FRAMING PLANS & DETAILS SYMBOL LEGEND m VIEW DIRECTION < cm� DETAIL/SECTION NUMBER WALL SECTION 1 rrnm� m o 'n S_ m z.:�Dm LOCATION OF -� -► cncn SECTION CUT z�z0 SHEET No. WHERE 0a -m SECTION IS LOCATED. O p t7 ZMm DETAIL/SECTION NUMBER ELEVATION 1 S-1 VIEW DIRECTION O>Z n r SHEET No. WHERE �Zr2D z SECTION IS LOCATED. n m DETAIL/SECTION NUMBER DETAIL 1 S-1 SHEET No. WHERE SECTION IS LOCATED. CALL OUT CUT/ MATCH LINE ELEVATION DATUM SLAB STEP X (INCHES) V N h a rn < m m rn v < cm� -i O rrnm� m o 'n m z.:�Dm -� -► cncn z�z0 c 0a -m D O p t7 ZMm o�m0 O g O O>Z n r �Zr2D z n m w I- 0 z O O L.LI V N GLS p 0 z V Z W O UQ z OU J Q zww CK 0 �- m :D u QU U w U) VJ L O v O Q U U � ....� J OD M 0 Ln zM�.� zj ro L1� M LLJ' M zo;� V z Q> Oz oU LLQ LL Le OLu Z un Q C/ V1 n ml Ln IN ■ MEMO MEMO11" PROJECT #: 18-304 DESIGNED: KCM DRAWN: KCM SCALE: AS NOTED ISSUED: 6/25/18 REVISION -1: REVISION -2: E lop e No 803 = :�•• STATE OF S a0 N AS 0� SHEET S-1 U w 0 U LL_ w z 0 0 >- J Z 0 V) z 0 z w p Z w 0 w U J J z w w z z w z Q 0 F - z w V) z O Z w F- 0 CL F- D 0 Q �w Om 00 Q Oz Z Qp z �0 �U ap CiLz oN LLI J z 00 = z w z__� p p W J UJ �Q p� °w w �p � Z OQ p�'z Lu U Lu Lu (� � J OQ Z= J N J � Q = O NU V)Q F_ CL Lu Z U0 ZU O U w Z~ Q 7 X wo p pIL ZCL QQ Jp Q w w wp aN Z Z0 w �Q z z O z QLu :�i �o p ULLj� J Z zU Z o� w LU w w Z_ r=- C� _ z� Lu 2 Z V, F- z Sf0 z 00 STRUCTURAL SHEATHING REQUIREMENTS IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY ALL BUILDING RESTRICTION LINES AND CITY ZONING REQUIREMENTS BEFORE CONSTRUCTION BEGINS. 2 S-3 MATCH w/ EXISTING BB -1 C? A 8F8-1 B A I / 2x10 No. 2 SYP FLOOR m JOISTS AT 16" O.C. m PLACE NEW FTG. m UNDER POST BEARING _ 5 FOR BEAM SUPPORT. LL S-3 SW18 I °0 I® IF24 • L I1777- m m NAIL DIAMETER ZONE 1 ZONE 2 ZONE 3 TYPE SHEATHING 0.113" ------------------ 10d x 1 z" NAIL EDGE/FIELD NAIL EDGE/FIELD NAIL EDGE/FIELD 0.120" t/1 SHINGLE/ 7/16" 3 4" 16d COMMON 0.162" > Ltl N LLI0 MEMB. OSB/PLY 8d R.S. 6"/12" O.C. 8d R.S. 6"/12" o.c. 8d R.S. 6"/6" o.c. METAL 15/32" 8d R.S. 6"/12" o.c. 8d R.S. 6"/12" O.C. 8d R.S. 6"/6" o.c. (ROOF) OSB/PLY • 19/32" PLY 10d 6"/12" o.c. 8d R.S. 6"/12" o.c. 8d R.S. 6"/6" o.c. (ROOF) R.S. • • 1 J J a_ t' x w � FLOOR 23/32" T&G OSB/PLY 10d OR 8d R.S. GLUED & NAILED - EDGES: 6" o.c; FIELD: 12" o.c. PORCH CEILINGS 3/8" OSB/PLY 8d EDGES: 3" o.c; FIELD: 6" o.c. WALLS 7/16"(MIN.) OSB/PLY SEE SHEAR WALL LEDGED 2x10 No. 2 SYP FLOOR m JOISTS AT 16" O.C. m PLACE NEW FTG. m UNDER POST BEARING _ 5 FOR BEAM SUPPORT. LL S-3 SW18 I °0 I® IF24 • L I1777- m m NAIL DIAMETER SW18 - -- ------ - 0.131" 21" 8d RINGSHANK 0.113" ------------------ 10d x 1 z" 0.148" z O 10d COMMON 0.148" 3" 10d RINGSHANK 0.120" t/1 _Q I-- 0.148" 3 4" 16d COMMON 0.162" > Ltl N LLI0 1 - 2x10 No. 2 SYP FLOOR m JOISTS AT 16" O.C. m PLACE NEW FTG. m UNDER POST BEARING _ 5 FOR BEAM SUPPORT. LL S-3 SW18 I °0 I® IF24 • L I1777- m m NAIL DIAMETER SW18 - -- ------ - 0.131" 21" 8d RINGSHANK 0.113" ------------------ 10d x 1 z" 0.148" 1. ALL WOOD STRUCTURAL SHEATHING SHALL BE APA RATED, EXPOSURE 1. 2. STRUCTURAL WOOD PANELS NOMINAL THICKNESS & SPAN RATINGS SHALL MEET 10d COMMON 0.148" 3" 10d RINGSHANK 0.120" 2 8" 12d COMMON 0.148" 3 4" 16d COMMON 0.162" 3 2' 1 - C THE FOLLOWING MINIMUM REQUIREMENTS: 7/16" =.437" THICKNESS - 24/16 SPAN RATING 15/32" =.469" THICKNESS - 32/16 SPAN RATING 19/32" =.594" THICKNESS - 40/20 SPAN RATING ' • • • p z • LL ' ^ V 0 LL U 1 S-2 B B m '- 00 • • 1 J J a_ t' x w � 23/32" =.719" THICKNESS - 48/24 SPAN RATING 3. ALL ROOF SHEATHING SHALL BE INSTALLED WITH THE LONG DIMENSION PERPENDICULAR TO THE ROOF SUPPORTS. 4. SHEATHING/SUBSTRATES & FASTENINGS FOR EACH ROOFING TYPE SHALL BE IN ACCORDANCE w/ THE FLORIDA PRODUCT APPROVAL. 5. ALL NAILS SHALL BE RING SHANK NAILS U.N.O. 6. 2x BLOCKING SHALL BE USED IN ROOF ZONES 2 & 3 FOR ALL EDGE SHEATHING FASTENING. FASTENER LEGEND 2x10 No. 2 SYP FLOOR m JOISTS AT 16" O.C. m PLACE NEW FTG. m UNDER POST BEARING _ 5 FOR BEAM SUPPORT. LL S-3 SW18 I °0 I® IF24 • L I1777- m m NAIL DIAMETER LENGTH 8d COMMON 0.131" 21" 8d RINGSHANK 0.113" 22" 10d x 1 z" 0.148" 1 2" 10d COMMON 0.148" 3" 10d RINGSHANK 0.120" 2 8" 12d COMMON 0.148" 3 4" 16d COMMON 0.162" 3 2' � Q= 1. ALL NAILS SHALL BE COMMON NAIL Q O UNLESS OTHERWISE NOTED ON THEU PLANS. r 2. INSTALL 10d NAILS IF NOT2 OTHERWISE NOTED ON THE PLANS. � � � 1 1 1 3. INSTALL THE APPROPRIATE W FASTENERS FOR PRESSURE W TREATED LUMBER. SEE NOTES ON O 00 B SHEET S-1. < 10 14'-6" MAX U FRAMING LEGEND 06 W (n 0'-0" EXIST. FIN. FLR. ELEV. _ 00 (ASSUMED DATUM) LL P111111111771717111 00 z D 8" CMU BEARING WALL W/ #5 @ 48" O.C. MAX AND AT Q LO CORNERS, INTERSECTIONS, AND EACH SIDE OF O Q • OPENINGS. • z J A FLOOR 7® STRUCTURAL LINTELS OR HEADERS AS SPECIFIED ON PLANS.O Q SHEATHING, SEE777 O SHEATHING REQ. A V1171111111111 STRUCTURAL BEAMS OR LEDGERS.U. v z STRUCTURAL WOOD POST C X STRUCTURAL COLUMN. SEE COLUMN SCHEDULE ON SHEET S-2.0. FILL IN EXIST. OPENING = FILLED w/ GROUT / U= UNFILLED j 00 9 QUANTITY OF #5 ADDED UREBAR AT -LIINTEL CAVITY FOR GRAVITY LOAD T. OF -1'-6" EXIST. GARAGE S-3 If %10 ON (ASSUMED DATUM) 8F16-1 B/1 T Q Ln N QUANTITY OF #5 ADDED REBAR Z z4z C-4 ON N NOMINAL WIDTH AT TOP OF '-"'71 Lr) N NOMINAL HEIGHT U -LINTEL CAVITY FOR UPLIFT Z d" Q LOAD Ll.r-• N m L.L.i M Lu N M co z _ -, t\ d- BEAM/LINTEL CROSS SECTIONS C,7 Q > d- Q zOz Ou uj ce O °` � _-_ - - --- (1) #5 (1) #5 LINTEL < U Adk BB -1 8F8-1 B a Omr Ln■ ■ man ■ CONCRETE/CMU BEAM SCHEDULE SIZE REINFORCING MARK STIRRUP SPACING TOP ELEV. WxD TOP MID BOT PROJECT #: 18-304 FOUNDATIONPLAN FRAMING PLAN BB -1 8" x 8" - - (1) #5 N/A MATCH EXIST. DESIGNED: KCM SCALE: 1/4" = F-0" SCALE: 1/4"= 1'-0" NOTES - 1 . OTES:1. CONTRACTOR TO VERIFY ALL BEAM ELEVATIONS W/ EXISTING SITE CONDITIONS. DRq�/N; KCM 2. REINFORCEMENT SHALL BE CONTINUOUS WITH 48 BAR DIAMETER LAPS. CONTINUOUS BOND BEAM WITH 3. USE (2) #5 X60" CORER BARS AT 30" EACH WAY FOR ALL CORNERS. 4. ALL BOTTOM REINFORCEMENT SHALL EXTEND A MINIMUM OF 8" INTO SUPPORTS. SCALE: AS NOTED MINIMUM 3000 PSI CONCRETE FLOOR JOISTS AND DECKING PER 5. PROVIDE 8F8 -1B PRECAST LINTEL BY CAST -CRETE (OR APPROVED EQUIVALENT) AND (1) #5 BAR ABOVE MASONRY OPENINGS U.N.O. FOUNDATION LEGEND FRAMING PLAN, TYP. 6. BB -1 TO BE INSTALLED AT THE TOP OF ALL MASONRY WALLS U.N.O. ON PLANS ISSUED: 6/25/18 8"X16" CMU STEMWALL. - aVERTICAL REINFORCEMENT VERTICAL REINFORCEMENT TO BE A No. 5,16" LG. DOWELS AT 16" O.C. EPDXY INTO EXIST. WALL, 6" REVISION -1: 8" CMU STEMWALL _ _ _ _ _ FOOTINGS DRILL & EPDXY (2) #5 BARS, 16" LG A] FROM NEW FTG. INT EXIST. FTG, 6" #5 DEFORMED BARS AT 48" O.C. MIN. EMBED. (FIELD VERIFY FILLED EXIST. CELL) FILL CELLS WITH MIN. 2,500 PSI FASTEN FLOOR JOIST TO LEDGER w/ REVISION -2: CONCRETE. SIMPSON U210 HANGERS, FILL ALL HOLES w/ 10d NAILS. TYP. 4x6 No. 2 SYP POST FOR BEAM SUPPORT. FASTEN LVL BEAM TO B POST w/ (2) HTS16 STRAPS. FASTEN BASE OF POST TO FTG. w/ FINISHED GRADE ABU46 HOLDOWN. ����`J�N....... C. It,1 1`0,� 2x10 No. 2 SYP LEDGER BOARD FASTENED TO BOND BEAM w/ 2" x 6" • T� FOOTING AND SLAB POURED WITH A // ANCHORS AT 12" O.C. STAGG. FASTEN END BEAM BEARING TO TOP OF EXISTING BOND/TIE o 8 *: MINIMUM OF 2,500 PSI CONCRETE. a 2 a BEAM w/ (2) DTT2Z HOLDOWNS. FILL ALL HOLES w/4"x1.25" SDS ° = SCREWS. DRILL & EPDXY z THREADED ROD ANCHOR MIN. 7" 1 / 00 6 MIL VAPOR BARRIER IN ;�' : STATE'0 MIN. EMBED VERTICAL REINFORCEMENT TO HAVE EMBED INTO EXIST. BOND/TIE BEAM � ;o . •� CRAWLSPACE 8" BEND AT BOTTOM AND BE -r '-.�s' ° R°• �,`�.� FOUNDATION NOTE �� -n ��'�ov0NA1-E�.�`� 2x10 No.2 SYP LEDGER BOARD i EMBEDDED 6" INTO TOP COURSE. FASTENED TO NEW OR EXIST. 1. CRAWLSPACE ACCESS PENINGS TO BE AT LEAST 18"X24" IN SIZEZ] C STEMWALL BOND BEAM w/ 2" x 6" AND NO GREATER THAN 3E" IN WIDTH. ADD (1) No. 5 REBAR ON EACH - SEE FND. SCHED. FOOTING TO BE PLACE ON ' ANCHORS AT 12" O.C. STAGG. VERIFY SIDE AND TOP OF CRAWLS ACE OPENING, POUR SOLID. (2) #5 BARS CONT. ON CHAIRS. CLEAN & COMPACTED SOILS, SHEET EXIST. IS FILLED SOLID AT LEDGER 2. CRAWLSPACE VENTILATION IS REQUIRED PER FBC-R408. TYP ATTACHMENT. CONTRACTOR IS RESPONSIBLE TO MEET THE MINIMUM CODE -0 FOR CRAWLSPACE VENTILATION. STEMWALL FTG. TYP. � S-2 FOUNDATION SCHEDULE TYPE MARK WIDTH LENG. THICKNESS REINFORCING BOTTOM TOP TRANSVERSE TYPE SW18 1'- 6" CONT. 10" (2) #5 CONTINUOUS N/A N/A EXTERIO STEMWALL IF24 2'-0" 2'- 0" 1' - 0" (2) #5 EACH WAY N/A N/A INTERIOR SPREAD FTG. #5 DEFORMED BARS AT 48" O.C. MIN. EMBED. (FIELD VERIFY FILLED EXIST. CELL) FILL CELLS WITH MIN. 2,500 PSI FASTEN FLOOR JOIST TO LEDGER w/ REVISION -2: CONCRETE. SIMPSON U210 HANGERS, FILL ALL HOLES w/ 10d NAILS. TYP. 4x6 No. 2 SYP POST FOR BEAM SUPPORT. FASTEN LVL BEAM TO B POST w/ (2) HTS16 STRAPS. FASTEN BASE OF POST TO FTG. w/ FINISHED GRADE ABU46 HOLDOWN. ����`J�N....... C. It,1 1`0,� 2x10 No. 2 SYP LEDGER BOARD FASTENED TO BOND BEAM w/ 2" x 6" • T� FOOTING AND SLAB POURED WITH A // ANCHORS AT 12" O.C. STAGG. FASTEN END BEAM BEARING TO TOP OF EXISTING BOND/TIE o 8 *: MINIMUM OF 2,500 PSI CONCRETE. a 2 a BEAM w/ (2) DTT2Z HOLDOWNS. FILL ALL HOLES w/4"x1.25" SDS ° = SCREWS. DRILL & EPDXY z THREADED ROD ANCHOR MIN. 7" 1 / 00 6 MIL VAPOR BARRIER IN ;�' : STATE'0 MIN. EMBED VERTICAL REINFORCEMENT TO HAVE EMBED INTO EXIST. BOND/TIE BEAM � ;o . •� CRAWLSPACE 8" BEND AT BOTTOM AND BE -r '-.�s' ° R°• �,`�.� FOUNDATION NOTE �� -n ��'�ov0NA1-E�.�`� 2x10 No.2 SYP LEDGER BOARD i EMBEDDED 6" INTO TOP COURSE. FASTENED TO NEW OR EXIST. 1. CRAWLSPACE ACCESS PENINGS TO BE AT LEAST 18"X24" IN SIZEZ] C STEMWALL BOND BEAM w/ 2" x 6" AND NO GREATER THAN 3E" IN WIDTH. ADD (1) No. 5 REBAR ON EACH - SEE FND. SCHED. FOOTING TO BE PLACE ON ' ANCHORS AT 12" O.C. STAGG. VERIFY SIDE AND TOP OF CRAWLS ACE OPENING, POUR SOLID. (2) #5 BARS CONT. ON CHAIRS. CLEAN & COMPACTED SOILS, SHEET EXIST. IS FILLED SOLID AT LEDGER 2. CRAWLSPACE VENTILATION IS REQUIRED PER FBC-R408. TYP ATTACHMENT. CONTRACTOR IS RESPONSIBLE TO MEET THE MINIMUM CODE -0 FOR CRAWLSPACE VENTILATION. STEMWALL FTG. TYP. � S-2 z 0 0 J z 0 V) z 0 V) z w z w w V) V) C z 3 Q n w Q 0 0 U J z ry w w z_ z Lu z Q 0 rVLL z w V) z 0 w rV 0 ryr 0 3 Q afw V) cc 00 �F- Q 0v) �z �O zF_ z �_0 ryU Qn �Z OV) 00 = 3w _z_2 00 w __j UJ �Q n� 0� �Lij> w ryp cy Z OQ r—) �,z Lu U V) w w U m J F_ J OQ z= J N J � Q0 U LnQ wZ U0 zU O UF- Z Q N X 00 ry on Z QQ J0 Qct� Lu w p QN 2O zuj U w Q z Z O w ULLJ� J Z b 0 Z F—V w Lu w w Z _ z� Lu 3 zV) �Z QO �z w CN n ROOF FRAMING NOTES 1. ALL ROOF FRAMING MATERIALS SHALL BE No. 2 SOUTHERN YELLOW PINE (SYP). 2. ALL RAFTER, JOISTS, BEAMS, AND OTHER FRAMING MEMBER SIZES ARE NOTED ON THE PLANS. 3. FASTEN ROOF RAFTERS/HIPS BEAMS TO NEW/EXISITNG SILL PLATES OR HEADER BEAMS W/ (2) 10d TOE -NAILS & (1) SIMPSON H4 CLIP. 4. FASTEN ROOF RAFTERS TO RIDGE/HIP BEAMS AND "SLEEPERS" W/ SIMPSON A35 CLIPS, (12) 8D X1.5" NAILS, U.N.O. 5. FASTEN NEW CEILING JOISTS TO NEW ROOF RAFTERS TOP PLATE INTERSECTION W/ (8) 16d NAILS AT EACH END. 6. FASTEN EXISTING ROOF RAFTERS TO NEW ROOF RAFTER w/ (8) 16d NAILS AT EACH INTERSECTION. 7. FASTEN COLLAR TIES TO ROOF RAFTERS w/ (8) 16d NAILS, EACH SIDE. COLLAR TIES SHALL NOT TO BE FASTENED HIGHER THAN 2/3 OVERALL ROOF RAFTER HEIGHT. 8. FASTEN HIPS TO RIDGE BOARD W/ SIMPSON A35 CLIPS W/ (12) 8D X1.5" NAILS. 9. FASTEN RAFTERS/JOISTS TO OTHER INTERSECTING RAFTERS/ JOISTS W/ (5) 10d TOE NAILS.. 10. ALL CEILING JOISTS LAP LOCATIONS SHALL FULLY BEAR OVER AN INTERIOR BEARING WALL OR SUPPORT, TYP. SCALE: 1/4" = Y-0" EXISTING ROOF RAFTERS,TYP.FASTEN EACH TO NEW SUPPORT ROOF RAFTERS, TYP. BEAM w! H2.SA CIPS SEE FRAMING PLAN FOR SPECS. 2x FASCIA FASTENED — — — — — — — — — — — — — — — — — — — — — — — — — — — TO RAFTERS w/ (2) 16d NAILS, TYP.---–––––– – – – – –––––––––––––– – – – r-- --------- ' I i I I FASTEN RAFTERS TO EXISTING EXTERIOR SILL PLATE w/ H4 CLIPS, 2x6 CEILING JOISTS WALL TO BE " AT 16O.C., TYP. TYP. DEMOLISHED NEW CMU WALL, SEE a TYPICAL WALL NEW MASTER BEDROOM I EXIST MASTER SECTION EXTENSION BEDROOM 14'-6" MAX 6 NEW ROOF SECTION CONVENTIONAL ROOF FRAMING, SEr ROOF FRAMING PLANS AND DETAILS FOI SPEC: SEE ARCHITECTURAL PLANS FOF ROOF COVERINGS & FLASHING,' MINIMUM ROOF SHEATHING TYPE, SIZE, i FASTENING PER SHEATHING LEDGED OI FRAMING PLAN SEE ROOF FRAMING NOTES & DETAIL FOR UPLIFT CONNECTOR 2x FASCIA BOARD. FASTEN TO EACF RAFTER ENDS w/ (2) 16d NAILS, TYF CMU BOND BEAM. w/ CONTIN REINFORCEMENT, SEE BEAM SCHEDULI FOR SPECIFICATION 8" CMU WALLS w/ #5 BAR REINFORCEMEN- & FILLED CELLS. SEE FRAMING PLAN FOF REINFORCEMENT SPECIFICATION REINFORCEMENT LAP TO BE A MIN. OF 41 BAR DIAMETERS, TYP SEE FOUNDATION PLAN WITHIN STRUCTURAL DRAWINGS FOR ALL FOOTING DETAILS. THIS IS FOR ILLUSTRATION ONLY AND MAY NOT REFLECT THE ACTUAL FOUNDATION SYSTEM. OND BEAM HT. MATCH EXIST 2X8 No. 2 SYP PT SOLE PLATE FASTENED TO TOP OF BOND BEAM w/ Z" ANCHORS & 3" SQ. WASHERS AT 36" O.C. MIN. EMBEDMENT TO BE 7" INTO BOND BEAM. PLACE (1) ANCHOR ON EACH SIDE OF PLATE SPLICE, TYP. VERICAL REINFORCEMENT TO EXTEND INTO BOND BEAM w/ MIN. 9" BEND. VERTICAL REINFORCEMENT TO BE #5 BARS AT 48" O.C. (32" IN CORNERS) AND FILLED w/ 3,000PSI CONCRETE. INSTALL 9 GAUGE DUR-O-WALL HORIZONTAL REINFORCEMENT EVERY OTHER COURSE (LADDER TYPE) PROVIDE CLEAN OUT AT BOTTOM & ADD WEEP HOLES AT 3 SPACING ALONG SPAN, TYP. SEE FOUNDATION PLAN & DETAIL ON SHEET S-2 FOR FLOOR FRAMING & ATTACHMENT TO STEMWALL, TYP. 0'-0" FIN. FLR 1 TYPICAL EXTERIOR WALL SECTION CONTINUOUS 2"X4" RIPPED DOWN W/FELT \ PAPER WOOD BUCK w/1/4 " -X3" LONG TAPCONS @ 12" O.C. MIN 1 4" EMBED. O ECURE DOOR JAMB TO WOOD BUCK PER PRODUCT APPROVALS ONTINUOUS 1"X4" P.T. FASTENED TO MASONRY 1/.099X 1 12' COIL NAILS @ 8" O.C. 3 TYP. EXTERIOR DOOR JAM DETAIL I ATTACH WINDOW FRAMES THRU BUCK INTO MASONRY W/ TAPCONS AS PER PRODUCT //AN�lA//AAAAAj��%/�A�i APPROVALS. MIN. 1 4" PENETRATION @ALL WD. TO MASONRY FASTENER CONNECTIONS CONTINUOUS 1"X4" P.T. WOOD BUCK FASTENED TO MASONRY W/.009 X1 2" COIL NAILS @ 8" o.c. (�- TYP. WINDOW JAM DETAIL 30" FOR #5 STARTER BAR. ALL SPLICES SHALL BE A MIN. 48 BAR DIAMETERS yJ CMU HORIZONTAL REINFORCING PER PLANS - (1) #5 CORNER BAR W/ 30" LAP SPLICE EA WAY EXISTING CEILING Z I : ] JOISTS, TYP. b BOND BEAM PER PLAN TOP OF FLOOR C) FASTEN NEW ROOF RAFTERS & TF EXISTING CEILING JOISTS TO NEW BEAM w/ LUS26 HANGERS, BON BEAM NEW SUPPORT BEAM Z FOR EXISTING & NEW ROOF FRAMING, SEE - 30" MIN. LAP FRAMING PLAN FOR SPECS. FASTEN CEILING 8"C.M. WALL OR ST MWALL JOISTS TO NEW BEAM I w/(6)16dTOENAILS, � — ` BOND BEAM CORNER -1 TYP. 8 DISCONTINUOUS REINF. SPLICE DETAIL FOR DBL. FILLED CELLS (SEE COLUMN SCHEDULE & PLAN) ONE BAR SHALL HAVE 12" HOOK INTO BOND BEAM TOP COURSE. PRE CAST LINTEL OPENING SIZE VARIES — — REFER TO ARCH PLANS BOND BEAM, SEE PLAN AND SCHEDULE FOR SIZE AND REINFORICNG TYPICAL LINTEL BELOW BOND BEAM 'CONS. I" EMBED 3ONRY UCK ALTERNATE FOR DCORS & S.G.D. INSTALLED PER MANUFACTURERS INSTRUCTIONS USING CONCRETE SCREWS THAT PENETRATE WOOD BUCKS AND EMBED INTO MASONRY: (THIS OPTION IS ONLY VALID WHEN DOORS & S.G.D. ARE ANCHORED DIRECTLY TO THE MASONRY) MINIMUM SCREW EMBEDMENT INTO MASONRY 1-1/4". ATTACH 1x BUCK W/ 6d FULL HEAD CASE HARD COIL NAILS @ 6" O.C. MIN. EMBED 1". ATTACH 2x BUCKS W/ 10d FULL HEAD CASE HARD COIL NAILS OR 0.148" DIA. HILTI X -DNI POWER ACTUATED FASTENERS @ 12" O.C. STAGGERED, MIN. EMBED 1-1/4". DOOR/WINDOW BUCK DETAIL EXISTING LINTEL OVER OPENING FILL IN OPENING WITH 8X16 CMU UNITS INSTALL TIES EVERY OTHER COURSE. VERIFY EXISTING CELLS ADJACENT TO OPENING ARE FILLED W/ CONCRETE. FILL NEW CMU UNITS ADJACENT TO EXISTING UNITS W/ 3,000 PSI CONCRETE, AS SHOWN. INSTALL 12" LG. No. 5 BARS AT 32" O.C. AROUND OPENING. DRILL & EPDXY BARS 6" INTO EXIST. CELLS AND EMBED 6" INTO NEW FILLED CELLS. EXISTING CMU WALLS FILL IN OPENING DETAIL 0 z • U (n z M 0 z Zj 0 MIN. 9" HOOK OF V% Q— VERTICAL REINF. INTO >V BOND BEAM Q Ln N LIC o EXISTING LINTEL OVER OPENING FILL IN OPENING WITH 8X16 CMU UNITS INSTALL TIES EVERY OTHER COURSE. VERIFY EXISTING CELLS ADJACENT TO OPENING ARE FILLED W/ CONCRETE. FILL NEW CMU UNITS ADJACENT TO EXISTING UNITS W/ 3,000 PSI CONCRETE, AS SHOWN. INSTALL 12" LG. No. 5 BARS AT 32" O.C. AROUND OPENING. DRILL & EPDXY BARS 6" INTO EXIST. CELLS AND EMBED 6" INTO NEW FILLED CELLS. EXISTING CMU WALLS FILL IN OPENING DETAIL 0 z • U � M Zj Q Ln zLn N Lu LL..- N L.LJ M N M zo;� > • V Z O z O Lu ce 0 z F_� F= � a Len n Q 0 Ln ■ ■ MEMO ■ ■ ■ ■ PROJECT #: 18-304 DESIGNED: KCM DRAWN: KCM SCALE: AS NOTED ISSUED: 6/25/18 REVISION -1: REVISION -2: �jjj Co lin,"��° �``� JAN ` O �'.•• STATE O F : �4/` SHEET S-3