Loading...
611 TIMBER BRIDGE LN RES18-0244 NEW SINGLE FAMILY PERMIT j-l - �� '= CITY OF ATLANTIC BEACH ?,' •t= 800 SEMINOLE ROAD 9,' ATLANTIC BEACH, FL 32233 '"0—iD INSPECTION PHONE LINE 247-5814 RESIDENTIAL - NEW SINGLE FAMILY RESIDENCE MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES18-0244 Description: Estimated Value: 360959.2 Issue Date: 8/8/2018 Expiration Date: 2/4/2019 PROPERTY ADDRESS: Address: 611 TIMBER BRIDGE LN RE Number: 169505 2090 PROPERTY OWNER: Name: TOLL FL VI LIMITED PARTNERSHIP Address: 250 GIBRALTAR RD HORSHAM, PA 19044 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: TOLL BROS.,INC Address: 250 GIBRALTAR RD STEVEN R MERTEN HORSHAM, PA 19044 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. C 1.m..kr,, City of Atlantic Beach APPLICATION NUMBER A Building Department (To be assigned by the Building Department.) l, 800 Seminole Road (� GS TI /� 2.4(( R 0 Atlantic Beach, Florida 32233-5445 '` JlJ Phone(904)247-5826 • Fax(904) 247-5845 oillwr 7 E-mail: building-dept@coab.us Date routed: / //?/!„' City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 4' ( ( h r 0 er B r tc e De• . ment review required Yes o 9 .... Bu. •.••p Applicant: TblI 1rid-kers 'tannin. & ••••= cc . ree •dministrator Project: Ji n9!G P:it-M t kj Public Utiliti Public Safety Fire Services Review fee $ Dept Signature Review or Receipt Other Agency Review or Permit Required Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: rgpproved. ❑Denied. 1 INot applicable (Circle one.) Comments: BUILDIN /�� PLA 1G &ZONING Reviewed by: /21' Date: 7. 31•l0 TREE ADMIN. Second Review: Approved as revised. fDenied.i Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 I �tyLy, ( City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by theQBuilding Department.) ` 800 Seminole Road R Es I U r d 2"((( '' �� Atlantic Beach, Florida 32233-5445 '� Phone(904)247-5826 • Fax(904)247-5845 � I % E-mail: building-dept@coab.us Date routed: /?/1d City web-site: http:/lwww.coab.us APPLICATION REVIEW AND TRACKING FORM t 11 ; � Property Address: 'eti5 r;cl j[) Department review required Yes No Bu. •.-99 To ( I 1rbers +Tannin• & •• •= Applicant: ree Administrator cci PIrn. tN Project: Jtn la Public Public Safety Fire Services Review or Receipt Date Other Agency Review or Permit Required of Permit Verified By Florida Dept.of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers . Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑ Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date:7-F1 ( TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ['Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05119/2017 r�y�,yrlJ City of Atlantic Beach APPLICATION NUMBER Building Department,; ��f,_ , (To be assigned by the Building Department.) ( a '!� 2 800 Seminole Road R Es 2T Atlantic Beach, Florida 32233-5445 p Phone(904)247-5826 • Fax(904)247-5841 JUL 18 2013 E-mail: building-dept@coab.us Date routed: 7//?/` City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: lQ ( l h ry\10 w-B r IGtge _ De. . ment review required Yes No vv Bu. • •r I O( I 73 io E/.SS _ 'tannin• & ••••= Applicant: ree Administrator Project: c>t le PIm. 1 Public UtilitH Public Safety Fire Services Review fee $ Dept Signature Review or Receipt Date Other Agency Review or Permit Required of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: pproved. ❑ Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed b . ` Date: 7,(r--(4, TREE ADMIN. ['Not applicable Second Review: ['Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑App roved as revised. ❑Denied. ❑Not applicable Comments: IIReviewed by: Date: Revised 05/19/2017 r5.=�1� City of Atlantic Beach APPLICATION NUMBER ��, (To be assigned by the Building Department.) s , Building Department �s r b 2'/�/ J T1s) 800 Seminole Road R T'(' Atlantic Beach, Florida 32233-5445 JUL 1 8 20� Phone(904)247-5826 • Fax(904)247-584 Q Date routed: 7//7//P E-mail: building-dept@coab.us l J;il�r BY: City web-site: http://viww.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: le ( ( \ U 13 r IGIge Department review required Yes No �/ _ Bu. ••••i TO I et Y S he •lannin• & ••••_ Applicant: ree Administrator ��`` � . • _Project: c..�t 9Ie Pim` \j Public Utiliti- Public Safety Fire Services Review fee $ 5 ) Dept Signature ,i --44111111111101 Review or Receipt Other Agency Review or Permit Required Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING �✓, (tip Date. i PLANNING &ZONING l ir Reviewed by:� TREE ADMIN. Second Review: ['Approved as revised. ['Denied. ❑Not applicable PU:.1�WORK Comments: • BLIC UTILITIES v PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ['Denied. ['Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 Building Permit Application Updated 12/8/17 City of Atlantic Beach ,•,v� 800 Seminole Road,Atlantic Beach,FL 32233 Phone:(904)247-5826 Fax:(904)247-5845 '6(.5 CC I Job Address: 611 Timber Bridge Lane Permit Number: r � Legal Description Lot 166 Atlantic Beach Country Club Unit 2, Parcel #67-52 16-25-29E RE# 169505-2090 Valuation of Work(Replacement Cost)$327940 Heated/Cooled SF 2728 Non-Heated/Cooled 1073 • Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): Commercial Residential • If an existing structure, is a fire sprinkler system installed?(Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: New home construction Florida Product Approval#see attached for multiple products use product approval form Property Owner Information Name: Toll FL VI Limited Partnership Address: 160 Cape May Avenue City Ponte Vedra State FL Zip 32081 Phone 904-217-0739 E-Mail aregnier@tollbrothers.com Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Toll FL VI, LP Contractor Information Name of Company: Toll Bros., Inc Qualifying Agent: Steven R. Merten Address 160 Cape May Avenue City Ponte Vedra State FL Zip 32081 Office Phone 904-595-5243 Job Site/Contact Number 904-595-5243 State Certification/Registration# CGC1510225 E-Mail aregnier@tollbrothers.com Architect Name& Phone# Toll Architecture(407)248-5800 Engineer's Name&Phone# Lou Pontigo&Associates(904)242-0908 Workers Compensation Policy#MWC30267702/Expries 9/1/2018 Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYI G TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINAN 0 , CONSULT WITH YOUR LENDER OR AN ATTOR Y BEFORE RECORDING YO 4r OTICE OF COMMENCEMENT. ii (Si: ure of Owner or Agent) ('lure of Contractor) (including contractor) Signed and sworn to(or affirmed)before me this I(0 day of Signed and s :rn to(or affirmed)before me this 1(o day of (901g , by ,S-lP,Vi 11/1ei4#- 2-Dko by ,,f/.P /14f./ $jgnature of Notary) Si ature of Notary) personally Known OR 4074°‘ Notary Public State of Florida 1 Personally Known OR NO�y ✓lIM�a!F(♦ridu [ ]Produced Identification • . Melissa Sue Lieberman ]Produced Identification Type of Identification: t •` My Commission GG 129088 ype of Identification: .001 ExM�pns Cw1M�rOiltWen t' 8 • - - �• � �Qd121111118 REVOCABLE ENCROACHMENT PERMIT REVOCABLE ENCROACHMENT PERMIT by the City of Atlantic Beach,Florida,a municipal corporation organized and existing under the laws of the State of Florida,hereinafter referred to as"CITY"and TOLL FL VI,LP of Atlantic Beach,Florida,hereinafter referred to as"USER". WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property for the purpose as described in the City of Atlantic Beach. This work is generally described as Pavers in the Right-of-Way for the driveway. . Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty(30) days' notice by CITY to USER, said notice to USER shall be given by certified mail, return receipt requested,to the following address 611 Timber Bridge Ln , Parcel#67-132 08-2S-29E • In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above described property of the CITY, the USER shall replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining, repairing, operating, replacing or adding to of the utilities and facilities of the CITY or franchise utility provider. • The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes, Land Development Code and all other land use and code requirements of the CITY,including City Code Section 19-7(h) which states"Driveways that cross sidewalks: City sidewalks may not be replaced with other materials, but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." • The USER,prior to making any changes from the approved plans and/or method,must obtain written approval from the City of Atlantic Beach Public Works Department,for said change within 30 days after the day of completion. • This permit shall inure to the benefit of,and be binding upon,the USER and their respective successors and assigns. • USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications,to include utilities locate requirements and use limitations/requirements of public right-of-ways and other public land. USER further agrees that the CITY and its officers and employees shall be saved harmless by the USER from any o ee work herein under the terms of this permit and that all of said liabilities are hereby assumed by the US .4 Sld Date /(f Property Owner/Ag: I t: Steven R. Merten,Division President,Toll FL VI LP (signed in presence o otary Public) STATE OF FLORIDA,COUNTY OF ST.JOHNS The foregoing instrument was acknowledged this ((o day of Mad-- ,201$ , by Sieve 4 G4-}A. ,who personally appeared before me and (printed name of Signer) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. S "4 . ur- of Notary Public,State of Florida Approved/Public Works Department: Personally Known c-_ '" Produced Identification(Type) / X40 Notary Public State of Florida? /�—' MelMyissa Sue LiebermanridScott ' l hams, 'ubllc Works Director Commission GG 128068 ,. %Os,„sc`' Expires 09/18/2021 -, • • .,3 • 4 RIGHT-OF-WAY/EASEMENT PERMIT Permit#Issued by the City of Atlantic Beach PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES Job Address 611 Timber Bridge Lane Phone 904-595-5243 Permittee Steven Merten Email areonierantollbrothers.com Requesting Permission to Construct Pavers in the Right of Way for the driveway Location (Reference to Cross-Street) Maritime Oak Dr&Timber Bridge Ln -06884 ATLANTIC BEACH COUNTRY CLUB UNIT 02 • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement,maintenance, safe and efficient operation, alteration or relocation of all,or any portion of said street or easement as determined by the Director of Public Works,any or all said poles,wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of Stacia Moore (Project Superintendent) located at 237 9th Avenue North,Suite 4,Jacksonville Beach,FL 32250 • All materials and equipment shall be subject to inspection by the Director of Public Works. • All city property shall be restored to its original condition as far as practical, in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • The permittee shall commence actual construction in good faith within days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,title and interest in the land to be entered upon and used by the holder,and the holder will,at all times, assume all risk of and indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and : 'vileges. • The Director of Pub ' orks shall be notified twenty-four(24)hours prior to starting work and again immediately upo o pletion. ' Date S ii Permittee: Steven R. erte ty vision President,TOLLFL VI,LP(signed in presence of Notary Public) STATE OF FLORIDA,COUNTY OF SAINT JOHNS The foregoing instrument was acknowledged this (p day of An,4 ,20 , by Sfe,Ve � . e fes, (�1 V PPESI IETr / ,who personally appeared before me and (printed name of Permittee) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. ' Personally Known V/ Signa tary Public, State of Florida Produced Identification(Type) Notary Public State of Florida Melissa Sue Lieberman • My Commission GG 126068 4y+0,4,t,, Expires 09/180021 /ei;''' .414'4' ') 'or% •r:( :>,.,1 Cit sjr` City of Atlantic Beach ti PUBLIC UTILITIES DEPARTMENT ty,. 1200 Sandpiper Lane Atlantic Beach, FL 32233 (904)247-5834 NEW WATER / SEWER TAP REQUEST Date 7`/9 -/ E Project Address '// //mti,3 C- k/e/ -e---- Number of Units / Commercial Residential Z Multi-Family New Water Tap(s) `3,/ , , & Meter(s) Meter Size(s) New Irrigation Meter V Upgrade Existing Meter from to (size) New Reclaim Water Meter Size New New Connection to City Sewer Applicant Name Applicant Address City State Zip Phone Cell Email Applicant Signature CITY STAFF USE ONLY Application ft JCS /8 0 Z`-/V Water System Development Charge $ / r P7 O, 00 , Sewer System Development Charge $ o ,4 Water Meter Only $ /8s , od Reclaim Meter Only $ / gc CY) Water Meter Tap $ Sewer Tap $ Cross Connection $ 5b, 01.) Other $ TOTAL $ S, 6 /0 r 06 (Notes) APPROVED Kayle Moore, P.E. 5 Date 7/� ( ( Public Utilities Director or Authorized Signature ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED OFFICE COI PERMITTED BUILDING DATA DO NOT WRITE BELOW — OFFICE USE ONLY Applicable Codes: 6th Edition (2017) Florida Building Code DEVELOPMENT SIZE: Habitable Space (ft2) Non-Habitable Space (ft") /O7 7 LAND INFORMATION: Zoning District d 13 C_ Flood Zone X / Minimum FFE 1/. 4i0 ; pram-r-e.! / 2 . Po BUILDING INFORMATION: Construction Type `f a Occupancy Group Si✓1si., �arrn,r'1 Number of Stories / Max Occupancy Load Fire Sprinklers Required /4/ 14- CONDITIONS/ COMMENTS: Rev. 2.7.2018 MAP SHOWING PLOT PLAN OF LOT 166 AS SHOWN ON MAP OF ATLANTIC BEACH COUNTRY CLUB UNIT 2 AS RECORDED IN PLAT BOOK 67 PAGES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLA CERTIFIED TO: TOLL BROTHERS, INC. p .. ,. fi LOT 144 LOT 145 S03'33'50"E 40 b 38. PLAT) N8OT05((148 E ,C� UTILITY, 38.05'(CALC) DRAINAGE CES EASEMENT 1 If. LOT 1 6 . o (VACANT)'" STORMWATER * MANAGEMENT + 0i $ FACILITY 3 DRAINAGE EASEMENT - CURVE DATA C2 a (CALC) - 58638'25"E 0 n CH = 38.47' p R = 590.00' J z CLOVE DATA C3 N85'370A•W A = 38.48' M p1 H.6024' I\ R-590.00• 4 = 03'4412A ATi A H. 6027' N 6-055110- N r h DUILDERS ENDORSEMENT — — SIGNED: _ , I D . /� 'e o NAME: DATE: _ /co ' PR2 a' ".1, ALL PAVERS N dr iWSTO I � , ALL MEASUREMENTS ESTIMATED @ FRONT 5413 SQ. FT, n Wh R o 4• / o BACK 278± SQ. FT. - • 'ff Mn 88. FF,[7' y) /..�. J a .1/ PNOPD5E0"I .. _ / .'i r- M m --�DENOTES DIRECTION OF FLOW in , M TYPE "B" DRAINAGE o �/ /_ ^ 3I ELEVATIONS SHOWN THUS (11.40) Co '/"' . a; WERE TAKEN FROM ENGINEERING PLANS 0 / • ff 7' '1 BY TAYLOR & WHITE, INC., DATED 04-15-14 Z 7.8 }.1 P• D 4 . ELEVATIONS SHOWN HEREON S a'' '-�=+ ARE;rar 4+ REFER TO NAVD OF 1988 /11 O Iii 10 020'-B.R.1 r5r„ .3' DIMENSIONS SHOWN HEREON ARE PER FOUNDATION PLAN L1 N89'27'38'W °� P"6Pp=En �°' ' 5 aWCWCI(PALER' P LOT 166 MODEL"CAPTIVA" 8.83' .• � p��AD(��y LOT SIZE 10,233± SQ. FT. _ �•_ p�1,.5.-'r�,���A DRIVEWAY TO R/W 3143 SQ. FT. 2U AU• _ . •,U -".NT ENTRY WALK 543 SQ. FT. METERS 3W-=.',,�r 2w CL RIGHT-OF-WAY LENGTH 60.41 FT. TOTAL IMPERVIOUS COVERAGE 4,203± SQ. FT. 41% PO ED CURVE DATA Cl TOTAL EASEMENT AREA 3,015± SQ. FT. TIMBER BRIDGE LANE CURB 4 CunER N8619'00"W TREE SCHEDULE (50' RIGHT OF WAY) CH = 51.55' R = 470.00' LOT SQ. FT. MINUS EASEMENTS/WETLANDS 7,218 A = 51.58' ACRES=7,218/43,560 0.17 4 = 0617.17• ACRESx40=REQUIRED TREE INCHES 6.8 THE REQUIRED NUMBER OF TREE INCHES WILL BE MET NOTE ALL UTIUTIES SHOWN USING 2" DIAMETER TREES. HEREON WERE FROM 707E OF REQUIRED PLANTED TREES SHALL BE CANOPY TYPE, AS-BUILT DRAWINGS WITH NO MORE THAN 50%OF THE SAME SPECIES. PROVIDED BY CODYS PROFESSIONAL SURVEYING AND MAPPING, INC. 12-18-14; JOB #10114 THE LOT SHOWN HEREON IS IN THE SPECIAL FLOOD HAZARD ZONE-7L'AS SHOWN ON FLOOD INSURANCE RATE MAP 0408 H FOR THE CRY OF JACKSONVILLE, FLORIDA.DATED 08-03-13 ALL AMERICAN SURVEYORS OF FLORIDA, INC. LAND SURVEYORS-J757 SAN JOSE PEACE;SLATE 15-J4CRSDM4/E FLORIDA 32257-904/279-0088-LICENSED LAND LIUSWESS M. 3857 Legend FPI. MOH 110ELPOMEN 5 COVERED 011 n�io. F NC 7'w cowlrloraR SKETCH FOR PLOT PLAN ONLY- DOES NOT REPRESENT OR PURPORT TO SHOW CAFTC M1 ' LAO � T OCIOONVILLEammoBOUNDARY L1NLS NOR IS R BASED ON A FIELDRUN SURVEY -4I ary ROA P.T. w N. M7'oOF6F WOO., LA f10roNR a'"m P.C.P. PF16yRprr CONTROL POINT ALL A DELTA C DNDIIDA KE P.C. POMP OF omm AMERICAN PAC. POOR CP 11FA.1E COR,a A LENGTH OF FLORIDA,v.0 P.C.C. POINT OF OF COMMIS/CIaAF SURVEYORS R RAMS SAL MALMO nunicRDR SURVEY NOT VALID UNLESS EMBOSSED BY SEALFLORIDA, LD!!r`1 (rn.)- POOR•LOUT JAMES D.HARRISON JR,No. 2847 /UC. MTI MICHAEL A.GARRETT,No.6643 MT L UP KW-NAT AAWL GEODETIC wRDDAIPOO N -cam MK POLO -M10600IRE ARMCO.SWIM SCALE �/ g 6/6 -R1010-OF-6U 9 Pl. H.KIK OF MRRSECIMIR p) -WOKS SS TOO -OPOF SRO DATE 04-26-18 GISTER�5�� MAPPl77 I-BI MAP SHOWING PLOT PLAN OF LOT 166 AS SHOWN ON MAP OF ATLANTIC BEACH COUNTRY CLUB UNIT 2 AS RECORDED IN PLAT BOOK 67 PACES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUVAL Comm; FLA. CERTIFIED TO: TOLL BROTHERS INC. LOT 144 LOT 145 503'33'50-E 38.05'((PLAT Ngg'25'58 E 40 ACCESS,UTILITY It 38.05'(CALC) ORAWACE EASEMENT fi5. b a. LOT 1 6 o - (VACANT)'" STORMWATER 1 t k MANAGEMENT MMtli�li ' GE\JEloMEN DRAINFACILITY 3 AGE EASEMENT CO `/pri:i. DATA C2 • Ap p 70.1 0 ir,cAL 588 CH = (3f8.47' 8M R = S1)O.00' J Z Q1RVE DATA CJ N65'J709•M A = 38.48' M 04-60.24' n R•590.00' 4 = 03'44'12' N A• 60.27. { i•. CM BUILDERS ENDORSEMENT _ _1.1___&_ SIGNED. _ / . _ l� NAME: DATE: _ S 2 L •3 ALL PAVERS NO I M F t- ALL MEASUREMENTS ESTIMATED Ai Wog FRONT 5411 SQ. FT. F ' 4soonwA o BACK 278* SQ. FT. .g F.�e7 ge• ' FF.E,.0 o) J ----,-DENOTES DIRECTION OF FLOW 01 t t 's TYPE TIO DRAINAGE o , li ' +�i ELEVATIONS SHOWN THUS (11.40) WERE TAKEN FROM ENGINEERING PLANS i ' ,� BY TAYLOR & WHITE, INC., DATED 04-15-14 .6 "'- PA74c,.°T a i ELEVATIONS SHOWN HEREON ) =t's=t#=1+ ; REFER TO NAVD OF 1988 / liSi 0 CAR 14 11 44C. 111 1D 020 BR, t`i_= DIMENSIONS SHOWN HEREON ARE PER FOUNDATION PLAN w1 PRS }t-"ROPoj;: L1 N89'2T38'W LOT 166 MODEL 'CAPTIVA" 8.83' I- E NT.o?! Y LOT SIZE 10,233* SQ. FT. 0 '"" 'O DOM ' ' iE__37- DRIVEWAY TO R/W 314± SQ. FT. 2 won V U DETERS ENTRY WALK 541 SQ. FT. �"�" 2 w TEAR R' .,4=9/411U. DETERS RIGHT-OF-WAY LENGTH 60.41 FT. TOTAL IMPERVIOUS COVERAGE 4.2031 SQ. FT. 41% PROPOSED c04 ,, CURVE DATA CI TOTAL EASEMENT AREA 3,0151 S0. FT. nM curia, 8 6 9'00eW BER BRIDGE WyE CH = 51.55' TREE SCHEDULE (50' RIGHT OF WAY) R = 470.00' LOT SQ. FT. MINUS EASEMENTS/WETLANDS 7,218 A = 51.58' ACRES..7,218/43,560 0.17 A = 081717* ACRESx40:REQUIRED TREE INCHES 6.8 THE REQUIRED NUMBER OF TREE INCHES WILL BE MET NOTE ALL UTIUTIES SHOWN USING 2 DIAMETER TREES. HEREON WERE FROM 70%OF REQUIRED PLANTED TREES SHALL BE CANOPY TYPE, AS-BUILT DRAWINGS WITH NO MORE THAN 50%OF THE SAME SPECIES. PROVIDED BY CODYS PROFESSIONAL SURVEYING AND MAPPING, INC. 12-18-14: JOB #10114 THE LOT SHOWN HEREON IS IN THE SPECIAL FLOOD HAZARD ZONE'X"AS SHOWN ON FLOOD INSURANCE RATE MAP 0408 H FOR THE CRY OF JACKSONVILLE, FLORIDA.DATED 06-03-13 ALL AMERICAN SURVEYORS OF FLORIDA, INC. LAND SURVEYORS-J751 SAN JOSE PLACE SU7E 15-,11CA'SOA MLLE, FLORIDA. 32257-904/279-0088-1J ENS D LMD BUSINESS NO 3857 Legend r.f.E. RNyI FLOOR ELEw1tlN PLAN _ 5 OM Dwain WC RR oaoRou M � SKETCH FOR PLOT ONLY- DOES NOT REPRESENT OR PURPORT TO SHOW 'f u'� r E ELECTRIC LINES NOR IS IT BASED ON A FIELD RUN SURVEY —41 CONC COIECREIE AA ACKNOMLE Mann ROA EIDAWR I.T. POMP of ONCENCY Ir. IRON PIPE P.C.P. PEMNDIT Q• L MITUL IRON pM ROD P.C. PONT Of CUM SURVEYOR D DELTA"'AI IAC. POM Or MORSE CURIE 6ORD P.C.C. P0POORDF COMPOUND CUM NOT VALID UNLESS EMBOSSED BY SEAL A MC SURVEYORS AIETEOiNOF AAL MAIM RESTRCRON R RAD. ) TiEaNDxE POSER•uarr ,LAMES D. HARRISON JR,Na 2847 FLORIDA. (uic) QUCuwEn MICHAEL A UNMET'',Na 6643 ANAT uNE 'M Wlw "c VERTICAL 1' 30' E •come EK ruw Nom AKRON VORTICAL SCALE �/ f. -comeRiaNr-LAE NOM 9 7.l PORK Or INIMEC ION N) •MESS ION TON OF NM DATE 04-2e-18 (FLOR CISTERED 5 R OR AIMPER I-8I S4a147 O -r p ralq FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation Residential Performance Method Project Name: Captiva.2728 Right S Builder Name: Toll Brothers,Inc. Street: Lot 166 Atlantic Beach CC Permit Office: Duval • City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Toll Brothers,Inc. Jurisdiction: 261300 Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) . 1. New construction or existing New(From Plans) 9. Wall Types(2580.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 2236.70 ft2 b.Frame-Wood,Adjacent R=13.0 343.33 ft2 3. Number of units,If multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 • 5. Is this a worst case? No 10.Ceiling-Types (2728.0 sqft.) Insulation Area • a.Under Attic(Vented) R=38.0 2538.00 ft2 6. Conditioned floor area above grade(ft2) 2728 b.Under Attic(Vented) R=19.0 190.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A. R= ft2 11. Ducts R ft2 • 7. Windows(359.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 442 • a. U-Factor: Dbl,U=0.34 359.00 ft2 : SHGC: SHGC=0.27 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 42.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A -ft2 a.Electric Heat Pump 42.0 HSPF:8.20 SHGC: - Area Weighted Average Overhang Depth: 6.031 ft. Area Weighted Average SHGC: 0.270 14.Hot water systems • a.Natural Gas Tankless Cap:1 gallons 8. FloorTypes (2728.0 sqft.) Insulation Area • EF:0.800 a.Slab-On-Grade Edge Insulation R=0.0 2728.00 ft2 b. Conservation features ' b.N/A R= ft2 •None c.N/A R= ft2 15.Credits Pstat • Glass/Floor Area: .0:132 Total Proposed Modified Loads: 67.1_3 PA Total Baseline Loads: 71.58 I hereby certify that the plans and specifications covered by • Review of the plans.and ;,vi0�'� 1E STA ;• this calculation are in compliance with the Florida Energy . specifications covered by this ti.-- r U� i , Code. calculation indicates compliance 3'c'`; ji„���'t y et_ ,>o-.v . Q / with the Florida Energy Code. rain ;'- 4.,;.0 n ' PREPARED BY: �.. ‘.3.14,0217///:r. �` �iyi wa.no Before construction is completed �w�, � �T� �o I DATE: 6`/'�P'.2-0-/g ' this building will be inspected for a ; •_ __ / h� s compliance with Section 553.908 * sx Florida Statutes. I hereby certify that this building,as designed,is in compliance ',f'`l; .. ••' 5`S'+ with the Florida Ener Code. , '<C�l7 Y1'1~T�;, �'''a (r , 4 eu�H OWNER/AGENT: �,r rif! ter"- BUILDING OFFICIAL: DATE: ( I 02 I ' DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as. certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). • 4/30/2018 8:25 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA Project Name: Toll Brothers,Inc. Permit# QESIE T C) 2 5/ Project Address: 611 Timber Bridge Lane Lot 166 As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) OFFICE COPY for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at:www.floridabuildin$.ork, Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A. EXTERIOR DOORS 1. Swinging Masonite Wood Edge,Steel N/A Double-FL8228.6 Single-FL6506.4 Simpson Door Company Wood Door FL 14487.1 Therma-Tru Fiberglass/Wood Door N/A FL 5262.3 2. Sliding PGT 2500 Aluminum Slide Glass +25/-25 FL 251 3. Sectional +43.2/-49.6 8 ft FL 9174.12 Wayne Dalton Section Ext.Door +39.2/-43.7 16ft FL 9174.15 4. Roll up 5.Automatic 6. Other B. WINDOWS 1. Single Hung PGT 5400 Vinyl Single Window +50/-50 FL 1435 2.Horizontal slider PGT 5400 Vinyl Hor.Window +50/-50 FL 1844 3.Casement 4. Double hung 5. Fixed PGT 5400 Vinyl Fixed Window +50/-50 F L 5012 6. Awning 7.Pass-through 8.Projected 9.Mullion PGT Alum/Vinyl Mullions N/A FL 261 10.Wind Breaker 11.Store Front/Mitred Glass Kawneer Glass Windows Mitred Glass Windows +30/-30 FL 10008.1 12. Glass Block US Block/Hy-Lite Glass Block Window 70 PSF FL 185.12 Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# C.PANEL WALL 1. Siding James Hardie Building Products,Inc. Lap Siding and Shingle Panels N/A FL 13192.2; 13192.4 James Hardie Building Products,Inc. Lap Siding and Shingles N/A FL 10477.1 FL 12098.3; 12098.1; Nichiha Corp. Lap Siding and Shingles N/A 12875.1 2.Soffits/Ceilings James Hardie Building Products,Inc. Soffit Panels N/A FL 13265.1 Nichiha Corp. Soffit Panels N/A FL 12098.4 3.EIFS 4.Storefronts Kawneer Glass Windows Mitred Glass +30/-30 FL 10008.1 5.Curtain walls 6.Wall louvers 7.Glass block _ 8.Membrane 9.Greenhouse 10. Synthetic Stucco 11.Other D. ROOFING PRODUCTS 1.Asphalt shingles GAF Corp. Timberline 30 year Arch Shingles N/A FL 10124.1 2.Underlayments Woodland Industries.Inc. Felt N/A FL 1814.12 Boral Roofing Roof Underlayment N/A FL 14317.1 3.Roofing fastners 4.Nonstructural metal roof Millennium Metals,Inc. Metal Roofing-M seam N/A FL 5211.3 R6 5.Built-up roofing 6.Modified bitumen 7.Single ply roofing 8.Roofing tiles 9.Roofing insulation 10.Waterproofing 11.Wood shingles/stakes Watkins Sawmill LTD. Wood Shingles and Shake N/A FL 13714.1 12.Roofing slate 13.Liquid applied roofing 14.Cement-adhesive coats 15.Roof tile adhesive 16.Spray applied polyurethane roof 17.Other PIi-Deck Walking deck membrane N/A FL 12407.1 Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# E. SHUTTERS 1.Accordion 2.Bahama 3.Storm panels Town and Country Industries Storm shutters N/A FL 11963 4.Colonial 5.Roll-up 6.Equipment 7.Other F. STRUCTURAL COMPONENTS 1.Wood connector/anchor Simpson Strong Tie Per engineering 2.Truss plates Alpine Engineered Truss plate conn. Per engineering 3.Engineered lumber Georgia Pacific Eng.Lumber FL 2023.1 4.Railing 5.Coolers-freezers 6.Concrete admixtures 7.Material _ 8. Insulation forms 9.Plastics 10.Deck-roof 11.Wall 12.Sheds 13.Other G.SKYLIGHTS 1.Skylight Sun Tek FGC Skylite FL 2442 2.Other H.NEW EXTERIOR ENVELOPE PRODUCTS 1 7/16"Zip Wall-Structural 1 OSB(roof and wall);manufacturered by Huber Engineered Woods 2 In addition to completing the above list of manufacturers,product description and State approval number for the products used on this project,the Contractor shall maintain on the job site and available to the Inspector,a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. ii v Audrey Regnier (Contractor Name) (Print Name) (Signature) Company Name: Toll Brothers,Inc. Mailing Address: 160 Cape May Avenue City: Ponte Vedra State: FL Zip Code: 32081 Telephone Number: 904 217-0739 Fax Number: Cell Phone Number: 904-405-8969 Email Address: aregnier@tollbrothers.com I.. ..,, ,,..._. BCS Li— BUILDING COMPONENT SUPPLY, INC. 4627 JP HALL BLVD. SUITE 208 GREEN COVE SPRINGS, FL 32043 0: 904.297.9390 F: 904.529. 1406 BEARING HEIGHTS L.. Li ' 91- 1 1 /B° 0 ///// 1 01- 1 1 /B 1 21- 1 1 /811 77.11-00 Ee in en in m eco Y- kb 6a !o er AN en d ery e / T2f THIS IS A TRUSS PLACEMENT Jg DIAGRAM ONLY. J36 These trusses are designed as ,§, •• , e-00-00 individual building components to be 7 J3t. incorporated into the building design at the specification of the building / J J05 n4 designer. See individual design sheets for each truss design identified on the „g placement drawing. The building ' j ' designer is responsible for temporary J34. and permanent bracing of the roof and T27 floor system and for the overall structure.The design of the truss szincluding headers, 4 qg 11 4 V01 a '' sbea s,swalls, and columns is the �,-.8,,,- ,<-� , ,1y i • , $ responsibility of the building designer. Jilt\ $ For general guidance regarding III bracing, consult"Bracing of Wood J14 Trusses"available from the Truss Plate III Institute, 583 D'Onifrio Drive; Madison, J1 ei ui WI 53179. 01 ATTENTION. ?"""""////f/, TT III Refer to truss layout and engineering `f documents that arrive with delivered 36-00- 00 \ 6-00.00 101• field trusses. T2$n Unless noted otherwise,all beams are ,1u p by others. TA 1, III REVISION DATE ti TATII CHECKED BY 00/00/15 III III \ T2f 111 729111 III ✓ CLIENT TOLL BROTHERS 111 \ ., % \III SUBDIVISION ATLANTIC BEACH 5-08.00 5-04.00 MODEL CAPTIVA f ELEVATION COASTAL DRAWN BY LOT # CJR DATE _AYO UT 166 06/20/20113 1 I REF# 1 5B 1 5T0 w z' I 1 2-2�• Q . z� ..s« ---...._______.,,w, \ 67-09.00 < 9-10-00 ,E =4_,c c i///f///,„(///, ',///✓ALU/I ///.g/Up ///I;j/// I/! /////////// /// //mV U/,_///e'A U. IIJ32 5 \ II r ITT730 II II 11J16 II w. 1iJ16 II I.I, \ I1J16 II - "111 6-00.00 '_d o eJ16 d Hum q 4 K ,J16 11 X YJ16 . II II.A6 2< II II J16 • II II r II ill1/1"30 II ��> // VO4 J32 / .V03 N / v II =r%////%////I/////////il vii.. .....�...>..«.. �<...�....,.»...>��r. >ii.,..i«epi«i�i<ii�r> \J06 J06 6-00_00 . 3211600 `J06 v. \JO6 Y \ .b �J06 i \J06 `101 ,J12 ''''? /i///i//dpi'//i/iiiiii/iii/.rii//iiiiiiaii/iiiiiii2i////7/iii/Yi/ii /iiii/i/i/.riiii/ii//?iii/riiii"iiii/a/iirniiii/ilii d74-11-00 87-09-00 FIRST FLOOR SCALE: 1 /, OFFICE COP ' FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation Residential Performance Method Project Name: Captiva 2728 Right S Builder Name: Toll Brothers,Inc. Street: Lot 166 Atlantic Beach CC Permit Office: Duval City,State,Zip: Atlantic Beach,FL, Permit Number: . Owner: Toll Brothers, Inc. Jurisdiction: 261300 Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2580.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=19.0 2236.70 ft2 b.Frame-Wood,Adjacent R=13.0 343.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 • 5. Is this a worst case? No 10.CeilingTypes (2728.0 sqft.) Insulation Area 2 a.Under Attic(Vented) R=38.0 2538.00 ft 6. Conditioned floor area above grade(ft2) 2728 b.Under Attic(Vented) R=19.0 190.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 . 11.Ducts R ft2 7. Windows(359.0 sqft.) Description Area ta.Sup:Attic,Ret:Attic,AH:Attic 6 442 • a. U-Factor: Da,U=0.34 359.00 ft2 , SHGC: SHGC=0.27 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 42.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency ' d. U-Factor: N/A .ft2 a.Electric Heat Pump 42.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 6.031 ft. Area Weighted Average SHGC: 0.270 14.Hot water systems • 8. Floor-Types (2728.0 sqft.) Insulation Area a.Natural Gas Tankless Cap: 1 gallons EF:0.800 a.Slab-On-Grade Edge Insulation R=0.0 2728.00 ft2 b. Conservation features . b.N/A R= ft2 None •• c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.132 . Total Proposed Modified Loads: 67.13 . -total Baseline Loads: 71.58 =PASS I hereby certify that the plans and specifications covered by : Review of the plans and ;'`'o" E STA� �;'{.;,, this calculation are in compliance with the Florida Energy specifications covered by this 0 ti ;;"'� 2� Q, ,u A. Code. calculation indicates compliance 47,7ii ',. •t i .�'. , with the Florida Energy Code. e �juu " a PREPARED BY: �� J���E��'e'i�i�`/va.rso Before construction is completed w i -+1 DATE: 6`/-342"2-0/g " this building will be inspected for 0 '# ::..CLi compliance with Section 553.908 .*'•.. of 4,.. •',7 ' Florida Statutes. N.;/;1;,.,-• * ' 'I hereby certify that this building,as designed,is in compliance �. with the Florida Ener Code. r '<< Ob Nags! ,.,....f.4" OWNER/ NT: 1�b-Q-�. BUILDING OFFICIAL: p. DATE: 1(LQ- DATE: 7. 31'i O - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as. certified factory-sealed in accordance with R403.3.2;1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 4/30/2018 8:25 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 PROJECT Title: Captiva 2728 Right S Bedrooms: 3 Address Type: Street Address • • Building Type: User Conditioned Area: 2728 Lot# Owner Name: Toll Brothers,Inc. Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Toll Brothers, Inc. Rotate Angle: 0 Street: Lot 166 Atlantic Beach Permit Office: Duval Cross Ventilation: No County: Duval • Jurisdiction: 261300 Whole House Fan: No City,State,Zip: Atlantic Beach, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE • Design-Temp Int DesignTemp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range , / FL,Jacksonville FL JACKSONVILLE INT 32 93 70 75 1281 -49 •Medium BLOCKS • Number . Name Area Volume 1 Block1 .2728 27280 :SPACES • -Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated . - . 1 Main 2728 .27280 Yes 4 3 1 Yes Yes Yes FLOORS V/ .# Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 190 ft 0 2728 ftz -- 0 0 1 ROOF / Roof Gable Roof • - Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. • (deg) / 1 Hip Composition shingles 3051 ftz 0 ftz Medium 0.6 N 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 2728 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 77 1 Under Attic(Vented) Main 38 Blown 2538 ftz 0.11 Wood • / 2 Under Attic(Vented) Main 19 Blown 190 ftz 0.11 Wood . 4/30/2018 8:25 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software , Page 2 of 4 • FORM R405-2017 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below ..\,(1# Ornt To Wall Type Space R-Value Ft• In Ft. In Area R-Vahia Frantinn Ahcnr (=rade% 1 S Exterior Frame-Wood Main 19 22 8 10 0 226.7 ft2 0 0.23 0.6 0 4 2 W Exterior Frame-Wood Main 19 78 0 10 0 780.0 ft2 0 0.23 0.6 0 - 3 N Exterior Frame-Wood Main 19 45 0 10 0 450.0 ft2 0 0.23 0.6 0 4 E Exterior Frame-Wood Main 19 78 0 10 0 780.0 ft2 0 0.23 0.6 0 • _ 5 S Garage Frame-Wood Main 13 34 4 10 0 343.3 ft2 0 0.23 0.01 0 DOORS V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In // 1 S Wood Main None .4 3 8 24 ft2 /• 2 S Wood Main None :4 .2 8 8 21.3 ft2 WINDOWS • • Orientation shown is the entered,Proposed orientation. / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp • .Area Depth . Separation Int Shade Screening 1 S 1 Vinyl Low-E Double Yes 0.34 0.27 N 50.0 ft2 5 ft 6 in 1 ft 0 in Drapes/blinds Exterior 5 2 W .2 Vinyl Low-E Double Yes 0.34 0.27 N 15.0 ft2 1 ft 4 in 1-ft 0 in Drapes/blinds Exterior 5 3 W 2 Vinyl Low-E Double Yes 0.34 0.27 N 12.0 ft2 1 ft 4 in '1 ft 0 in None Exterior 5 4 W .2 Vinyl Low-E Double Yes 0.34 0.27 N 12.0 ft2 1-ft-4 in 1-ft 0 in None Exterior 5 - • 5 N 3 Vinyl Low-E Double Yes 0.34 0.27 N 60.0 ft2 1 ft 4 in 1-ft 0 in Drapes/blinds Exterior 5 . 6 N 3 Vinyl Low-E Double Yes 0.34 0.27 N 18.0 ft2 11 ft 0 in 1 ft 0 in None Exterior 5 7 N 3 Vinyl Low-E Double Yes 0.34 0.27 N 128.0 ft2 11 ft 0 in 1.ft 0 in None Exterior 5 • 8 E -4 Vinyl Low-E Double Yes 0.34 0.27 N 12.0 ft2 1 ft 4 in 1 ft 0 in None• Exterior 5 9 E 4 Vinyl Low-E Double Yes 0.34 0.27 N 36.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5 10 S 1 Vinyl Low-E Double Yes 0.34 0.27 N 16.0 ft2 5•ft 6 In 1 ft 0 in None •Exterior 5 GARAGE ✓/ -# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation • 1 669 ft2 669 ft2 72 ft 10 ft 0 INFILTRATION • •# Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 • 1 Wholehouse Proposed ACH(50) .000445 3182.7 174.72 328.59 .3425 7 HEATING SYSTEM ,• . V1 •# System Type Subtype Efficiency Capacity • Block Ducts 1 Electric Heat Pump/ Split HSPF:8.2 42 kBtu/hr 1 sys#1 4/30/2018 8:25 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts . 1 Central Unit/ Split SEER:14 42 kBtu/hr 1260 cfm 0.77 1 sys#1 HOT WATER SYSTEM - V./ # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Exterior 0.8 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC . • Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF / None None ft2 DUCTS — Supply---- ---Return--- Air CFM 25 CFM25 HVAC# V// # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 ••• Attic 6 442 ft? Attic 145 ft2 Default Leakage Attic • (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: ' Cooling [[ ]]Jan [[ ]]Feb [[ ]Mar A r [ ]Ma [X)Jun [X]Jul X]Au [X]Se ]Oct [ ]Nov Dec Heatin [X]Jan [X]Feb X Mar f Apr [ ]Ma [ ]Jun [ Jul 4 Aug [ ]SeOct [X]Nov X Dec Venting• [[ ]]Jan [[ 1]Feb X]Mar [X Apr [ l May [ ]Jun [ ]Jul • [ )Aug [ ]]Sep 'X]]Oct [X]Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 • 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 ._.... _Heating(WEH)_ AM._ . ..SS..._. ss.. 66 – 66 666 68_ ...... 68.'- . . 68__... _ . 68 Sg... .. . 68. •. -..68 ... ._. ._- PM 68 68 68 68 68- 68 68 68 68 68 66 66 4/30/2018 8:25 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD • ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the EnergyPerformance Index, the more efficient the home. Lot 166 Atlantic Beach CC, Atlantic Beach, FL, . 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area a.Frame-Wood,Exterior R=19.0 2236.70 ft2 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 343.33 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 2538.00 ft2 6. Conditioned floor area(ft2) 2728 b.Under Attic(Vented) R=19.0 190.00 ft2 c.N/A R= ft2 7. Windows** Description Area R ft2 a. U-Factor: Dbl,U=0.34 359.00 ft2 11.Ducts a.Sup:Attic,Ret:Attic,AH:Attic 6 442 SHGC: SHGC=0.27 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 42.0 SEER:14.00 SHGC: d. U-Factor: N/A' ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 42.0 HSPF:8.20 Area Weighted Average Overhang Depth: 6.031 ft. Area Weighted Average SHGC: 0.270 8. Floor Types Insulation Area 14.Hot water systems Cap: 1 gallons a.Slab-On-Grade Edge Insulation R=0.0 2728.00 ft2 a.Natural Gas EF:0.8 b.N/A R= ft2 b. Conservation features c.N/A R= ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building .+ , 1111EsT4 ,+}. Construction through the above energy saving features which will be installed (or exceeded) ; yo:-,h ;- .:�J in this home before final inspection. Otherwise, a new EPL Display Card will be completed �,,,��,,�,� . based on installed Co compliant features. . 1Thi" Builder Signature: Date: ; I�' �' ; 'c',I t Cit /FL Zip: 4 '.:1:••• `� Address of New Home: V" I , M be✓ vS r, � City 0 �- 13 C11. Q°1)-WE---.•..- :•'. c;C *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building - Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/30/2018 8:25 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: Lot 166 Atlantic Beach CC Permit Number: Atlantic Beach,FL, MANDATORY REQUIREMENTS See individual code sections for full details. • SECTION R401 GENERAL R401.3 Energy Performance Level(EPL)display card(Mandatory).The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components • installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans • and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402:4.1 through R402.4.5. • Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4:1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4:1.1 and R402.4.1.2.The sealing • methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Instaliation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's Instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4:1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding,seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. • Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3. Interior doors,if installed at the time of the test,shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems,if installed at the time of the test,shall be turned off. 6. Supply and return registers,if installed at the time of the test,shall be fully open. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air IeakageWindows,skylights and sliding glass doors shall have an air infiltration rate of•no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 4/30/2018 8:25 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 1 of 5 • MANDATORY REQUIREMENTS - (Continued) R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be locatedoutside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage • between conditioned and unconditioned spaces.-All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not • • more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). • Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways . for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or (7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. R403.3.2:1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than.2 percent of the design airflow rate when tested in accordance with ASHRAE 193. • R403.3.3 Duct testing(Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa)across the system,including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test. • 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test. Exceptions: . 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. ' A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums." R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,includingthat caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited. . Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and • when there is no demand for hot water. R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 4/30/2018 8:25 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017)Complian Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped'with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3'Y2 inches(89 mm)in the hot water distribution line and cold water line-located as close as possible to the storage tank. • R403.5.6 Water heater efficiencies(Mandatory). • R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of combustion types of service water-heating systems to be turned off. R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed: • Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, . and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems should meet the following criteria: • 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation including:Natural, Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. 1. -The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for-residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawispaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10 otherwise. R403.7 Heating and cooling equipment(Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6:1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMUM (CFM) (CFM/WATT) (CFM) Range hoods Any 2.8 cfm/watt Any In-line fan. Any 2.8 cfm/watt Any Bathroom,utility room 10 1.4 cfm/watt <90 Bathroom,utility room 90 2.8 cfm/watt Any For SI:1 cfm=28.3 L/min. a. When tested in accordance with HVI Standard 916 4/30/2018 8:25 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of • equipment may be sized in accordance with good design practice. R403.7:1.2 Heating equipment capacity. • R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. • R403.7:1;3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an • • intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the-IECC—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8°C). • R403.10 Pools and permanent spa energy consumption(Mandatory). • • • The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10:1 Heaters. The electric power to heaters shall-be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule • shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require.24-hour pump operation. 2. Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. _ 4/30/2018 8:25 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas(Mandatoryl)he energy consumption of electric-powered portable spas shall be controlled by the requirements ofAPSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be . high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception:Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory).Fuel gas lighting systems shall not have continuously burning pilot lights. • • • 4/30/2018 8:25 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 5 of 5 i 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA i TABLE 402.4.1.1 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA • Project Name: Captiva 2728 Right S Builder Name: Toll Brothers,Inc. . Street: Lot 166 Atlantic Beach CC Permit Office: Duval . City,State,Zip: Atlantic Beach,FL, Permit Number: . Owner: Toll Brothers,Inc. Jurisdiction: 261300 Design Location: FL,Jacksonville • COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall • The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. . The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls - The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity.with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and • continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation -- and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. • Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on Narrow cavities -installation readily conforms to the available cavity'•.. spaces. Garage separation Air sealing shall be provided between the garage and conditioned spats. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication • exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids 7 between fire sprinkler coverplates and walls or ceilings a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 4/30/2018 8:25 PM EnergyGauge®USA-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 • FORM R405-2017 Envelope Leakage Test Report Performance FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION • • Envelope Leakage Test Report Performance Method Project Name: Captiva 2728 Right S Builder Name: Toll Brothers,Inc. Street: Lot 166 Atlantic Beach CC Permit Office: Duval City,State,Zip: Atlantic Beach, FL, Permit Number: Design Location: FL,Jacksonville Jurisdiction: 261300 • • Cond.Floor Area:: 2728 sq.ft. Cond.Volume: 27280 cu ft. • • Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: Single or Multi Point Test Data Required ACH(50)from HOUSE PRESSURE FLOW: FORM R405-2017 : 1 Pa cfm 2 Pa cfm Tested ACH(50)'*: 3 Pa cfm *Tested leakage must be less than or equal to the 4 Pa cfm required ACH(50)shown on Form R405-2017 for 5 Pa cfm • this building. If the tested ACH(50)is less than 3 the building must have a mechanical ventilation 6 Pa cfm system. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2...Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or Individuals licensed as set forth in Section 489.105(3)(f), (g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test.and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,Makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3. Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers, if installed at the time of the test,shall be fully open. '�. •st•.•�AAS+ , y. I hereby certify that the above envelope leakage Testing shall be conducted by either ,; off� E• rq? performance results demonstrate compliance . individuals as defined in Section _ � t ; a . vs' with 553.993(5)or(7), Florida Statutes or �i,,T R *� �,o with Florida Energy Code requirements in � • individuals licensed as set forth in 'm '5*w, „•,'�,,; O accordance with Section R402.4.1.2. �: t Section 489.105(3)(f), (g), or(i)or an '�)," IRV d,y approved third party.A written report of e t! the results of the test shall be signed * J ; SIGNATURE: by the third party conducting the test ��f� f' :•-• e and provided to the code official. GpD' ': t�,.;}. PRINTED NAME: "'�••_ ��'"' BUILDING OFFICIAL: air DATE: DATE: 1/ 7"3/ 400/ 4/30/2018 8:25 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 • Project Summary Job: Lot 166 ABCC 1f _ 644p� (Rest of House) By: Saldie Guintivano McGowan's Heating & Air Conditioning, Inc. 11320 E.Phillips Parkway Dr.,Jacksonville,H 32256 Phone:904-278-0339 Fax 904-278-0366 Email:saldie@mcgowansac.com Web:www.mcgowansac.corn Pro'ect Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone:904-217-0739 Fax: 904-814-8173 Web:tolbrothers.com Email: smerten@tollbrothersinc.com Notes: CAPTIVA Desi•n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 24 °F Daily range M Relative humidity 50 Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 31587 Btuh Structure 20752 Btuh Ducts 3771 Btuh Ducts 4666 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 35359 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 28034 Btuh Method Blower door Latent Cooling Equipment Load Sizing Shielding/stories 3(partial)/1 Pressure/AVF 50 Pa/3209 cfm Structure 6823 Btuh Ducts 826 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ftl 2728 2728 Equipment latent load 8181 Btuh Volume (ft3) 26623 26623 Air changes/hour 0.55 0.33 Equipment Total Load(Sen+Lat) 36215 Btuh Equiv.AVF (cfm) 244 146 Req. total capacity at 0.70 SHR 3.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model CH14NB0420000A0 Cond CH14NB0420000A0 AHRI ref 9162578 Coil FB4CNP042L AHRI ref 9162578 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 28000 Btuh Heating output 41000 Btu h @ 47°F Latent cooling 12000 Btuh Temperature rise 30 °F Total cooling 40000 Btuh Actual air flow 1225 cfm Actual air flow 1225 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.77 Capacity balance point=29°F Backup: Input=8 kW, Output=28802 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2018-Apr-3020:19:44 Comfort Builder by Wrightsoft 18.0.11 RSU03444 Page 1 ...rolhers\Captiva 2728 Right S-Lot 166 ABCC.rup Calc=MJ8 Front Door faces: S N First Floor master bed 14 x 14 12 x6 12 12 x6 7' 7 r� ,•, ' ••, m.wic2 6x10 dining 6„ m:Wlc 4x8. •,,«? 12x6 10 x6 5" great rm. 3"Fan 0j 8x4 4.. m.bath 12„ �i 00 3"Fan 0 0 6x12 s.. 6x10 �,. : 6„ 16 kitchen„ bed 2 � '..2x6 10 0 •• 24x18 _ J11IiI* Oa 12x12 8x4 ,0x68x4 111 4 wic2 4” 6„ 12x12 10x61 J10810 bath 2 8" 6 ........www • r•. • Ale aj "Fan aj 14 " 12' 3"Fan F. study bath3 644, wic 3 8x4 8 allidlik 10x6 18,. IL" 2 .1-.S14i=AI 12 x6 12 x 12 foyer bed 3 GARAGE Job#: Lot 166 ABCCMcGowan's Heating & Air Conditionin., Scale: : 123 Performed by Saldie Guintivano for: Page 1 Steve Merten 11320 E.Phillips Parkway Dr. Comfort Builder by Wrightsoft 160 Cape May Ave. Jacksonville,Fl 32256 Ponte Vedra,Fl 32081 18.0.11 RSU03444 Phone:904-217-0739 Fax:904-814-8173 Phone:904-278-0339 Fax:904-278-0366 2018-Apr-30 20:20:04 tolbrothers.com smerten@tollbrothersinc.com www.mcgowansac.com saldie@mcgowansac.com .. 2728 Right S-Lot 166 ABCC.rup Manual S Compliance Report Date: Lot 166 ABCC A{re.„ttafcd ` '` (Rest of House) By: Saldie Guintivano . .... McGowan's Heating & Air Conditioning, Inc. 11320 E.Phillips Parkway Dr.,Jacksonville,Fl 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie©mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: 904-217-0739 Fax: 904-814-8173 Web: tolbrothers.com Email: smerten@tollbrothersinc.com Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 28034 Btuh Entering coil DB: 75.8°F Outdoor design WB: 80.2°F Latent gain: 8181 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 36215 Btuh Indoor RH: 50% Estimated airflow: 1225 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH 14NB0420000A0+FB4CNP042L Actual airflow: 1225 cfm Sensible capacity: 27922 Btuh 100%of load Latent capacity: 8343 Btuh 102%of load Total capacity: 36265 Btuh 100%of load SHR: 77% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 35359 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0420000A0+FB4CNP042L Actual airflow: 1225 cfm Output capacity: 32361 Btuh 92%of load Capacity balance: 29 °F Supplemental heat required: 2998 Btuh Economic balance: -50 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1225 cfm Output capacity: 8.4 kW 81%of load Temp. rise: 24 °F Meets all requirements of ACCA Manual S. w iightsoft' 2018-Apr-30 20:19:44 _•- •- -...- Comfort Builder by Wrightsoft 18.0.11 RSU03444 Page 1 AC ...rothers\Captiva 2728 Right S-Lot 166 ABCC.rup Calc=MJ8 Front Door faces: S Duct System Summary Job: Lot 166 ABCC Date: � ,ata (Rest of House) By: Saldie Guintivano McGowan's Heating & Air Conditioning, Inc. 11320 E.Phillips Parkway Dr.,Jacksonville,Fl 32256 Phone:904-278-0339 Fax 904-278-0366 Email:saldie@mcgowansac.corn Web.www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: 904-217-0739 Fax: 904-814-8173 Web:tolbrothers.com Email: smerten@tollbrothersinc.com Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.269/0.121 in H2O 0.269/0.121 in H2O Lowest friction rate 0.074 in/100ft 0.074 in/100ft Actual air flow 1225 cfm 1225 cfm Total effective length (TEL) 524 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln(ft) Trunk bath 2 c 1264 59 61 0.090 4.0 Ox 0 VIFx 58.5 240.0 st3 bath 3 c 93 2 4 0.116 4.0 Ox 0 VIFx 37.1 195.0 st2 bed 2 c 2107 78 102 0.090 7.0 Ox 0 VIFx 57.5 240.0 st3 bed 3 h 5177 179 133 0.111 7.0 Ox 0 VIFx 47.8 195.0 st2 dining c 2910 139 140 0.103 7.0 Ox 0 VIFx 52.0 210.0 st5 foyer h 1987 69 64 0.113 5.0 Ox 0 VIFx 42.1 195.0 st2 great rm.-A c 1634 75 79 0.075 6.0 Ox 0 VIFx 80.9 275.0 st4 great rm.-B c 1634 75 79 0.089 6.0 Ox 0 VIFx 61.8 240.0 st3 hall c 337 8 16 0.116 6.0' Ox 0 VIFx 37.3 195.0 st2 kitchen c 3453 122 166 0.111 7.0 Ox 0 VIFx 33.1 210.0 st5 laun. h 1551 54 53 0.115 4.0, Ox 0 VIFx 28.1 205.0 st5 m.bath c 1273 52 61 0.076 5.0 Ox 0 VIFx 75.3 280.0 st4 m.wic h 1026 36 21 0.077 4.0 Ox 0 VIFx 74.7 275.0 st4 m.wic 2 c 84 2 4 0.077 4.0 Ox 0 VIFx 72.7 275.0 st4 master bed-B h 3051 106 87 0.075 7.0 Ox 0 VIFx 78.2 280.0 st4 master bed-C h 3051 106 87 0.075 7.0 Ox 0 VIFx 76.6 280.0 st4 pan. c 91 2 4 0.116 4.0 Ox 0 VIFx 27.3 205.0 st5 study-A c 738 32 36 0.114 6.0 Ox 0 VIFx 30.8 205.0 st5 we c 62 1 3 0.074 4.0 Ox 0 VIFx 81.2 280.0 st4 wic 2 c 88 2 4 0.091 4.0 Ox 0 VIFx 56.9 240.0 st3 wic 3 h 780 27 18 0.111 4.0 Ox 0 VIFx 47.4 195.0 st2 wrightsoft- 2018-Apr-30 20:19:44 `+- , ,- - ..,...-.. ..-. Comfort Builder by Wrightsoft 18.0.11 RSU03444 Page 1 AC . ...rothers\Captiva 2728 Right S-Lot 166 ABCC.rup Calc=MJ8 Front Door faces: S Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 377 343 0.074 480 12.0 0 x 0 VinIFIx st3 st3 Peak AVF 591 589 0.074 553 14.0 0 x 0 VinIFIx st2 st1 Peak AVF 1225 1225 0.074 693 18.0 0 x 0 ViniFlx st2 Peak AVF 876 825 0.074 627 16.0 0 x 0 VinIFIx st1 st5 Peak AVF 349 400 0.103 509 12.0 0 x 0 VinIFIx st1 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb2 Ox 0 63 62 138.6 0.088 45 16.0 Ox 0 VIFx rt1 rb6 Ox 0 301 262 163.1 0.074 383 12.0 Ox 0 VIFx rt1 rb3 Ox 0 208 222 138.1 0.088 635 8.0 Ox 0 VIFx rt1 rb5 Ox 0 229 262 144.9 0.084 593 9.0 Ox 0 VIFx rt1 rb4 Ox 0 423 417 77.6 0.156 959 9.0 Ox 0 VIFx Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 Peak AVF 802 808 0.074 457 18.0 0 x 0 VinIFIx +: -{ - wrightsoft. 2018-Apr-30 20:19:44 ,w ..-- Comfort Builder by Wrightsoft 18.0.11 RSU03444 Page 2 ...rothers\Captiva 2728 Right S-Lot 166 ABCC.rup Calc=MJ8 Front Door faces: S Static Pressure and Friction Rate Job: Lot 166 ABCC Date: (Rest of House) By: Saldie Guintivano McGowan's Heating & Air Conditioning, Inc. 11320 E.Phillips Parkway Dr.,Jacksonville,Fl 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie@mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: 904-217-0739 Fax: 904-814-8173 Web: tolbrothers.com Email: smerten@tollbrothersinc.com Available Static Pressure Heating Cooling (in H2O) (in H2O) External static pressure 0.50 0.50 Pressure losses Coil 0.06 0.0E Heat exchanger 0 0 Supply diffusers 0.02 0.02 Return grilles 0.03 0.02 Filter 0 0 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.39 0.39 Total Effective Length Supply Return (ft) (ft) Measured length of run-out 10 33 Measured length of trunk 71 25 Equivalent length of fittings 280 105 Total length 361 163 Total effective length 524 Friction Rate Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.074 OK 0.074 OK Return Ducts 0.074 OK 0.074 OK Fitting Equivalent Length Details Supply 4AD=60, 11C=40, 11G=5, 11C=40, 11C=40, 11G=5, 11C=40, 1A=35, 11G=5, 11G=5, 11G=5:TotalEL=280 Return 6L=20, 11C=40, 11G=5, 5E2=35, 11G=5:TotalEL=105 4121- wrightsoft` 2o18-Apr-3020:19:44 Comfort Builder by Wrightsoft 18011 RSU03444 .- ..,,.�..... . . Page 1 ...rothers\Captiva 2728 Right S-Lot 166 ABCC.nip Calc=MJ8 Front Door faces: S