Loading...
1660 ATLANTIC BEACH DR - NEW SINGLE FAMILE PERMIT (-- \ ' '4�',.lri\ . �ACITY OF ATLANTIC BEACH ;tr," �' 800 SEMINOLE ROAD � x ATLANTIC BEACH, FL 32233 .0;119 INSPECTION PHONE LINE 247-5814 RESIDENTIAL - NEW SINGLE FAMILY RESIDENCE MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES18-0246 Description: Estimated Value: 439304.5 Issue Date: 8/8/2018 Expiration Date: 2/4/2019 PROPERTY ADDRESS: Address: 1660 ATLANTIC BEACH DR RE Number: 169505 2045 PROPERTY OWNER: Name: ATLANTIC BEACH PARTNERS LLC Address: 414 OLD HARTS RD STE 502 FLEMING ISLAND, FL 32003 GENERAL CONTRACTOR INFORMATION: Name: Address: , Phone: Name: TOLL FL VI LIMITED PARTNERSHIP Address: 250 GIBRALTAR RD HORSHAM, PA 19044 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. rS A, City of Atlantic Beach APPLICATION NUMBER ;. ' ' \sz\ Building Department (To be assigned by the Building Department.) r : 800 Seminole Road Q a- r f� �C 2[Le ,. - Atlantic Beach, Florida 32233-5445 !�G.�!V O l Phone(904)247-5826 • Fax(904) 247-5845 ( ,tjr E-mail: building-dept@coab.us Date routed: /l /C City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: l(.Q( .0 NA-66c Be, ' �e•artment review required �' o uildi.• W,- Applicant: "MU -Bros •�S .' annin• &Zoning ree ••u. is ra or Project: I n ( e EC jy ( ( ` �ublic irk, A • 9 'u•lic Safety Fire Services _a Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. Denied. ['Not applicable (Circle one.) Comments: esBU DING /1J PL• 1 1 NG &ZONINGReviewed by: V r ` Date: (f ( �� TREE ADMIN. Second Review: ❑Approved as revised. ❑D ed. I INot applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 Building Permit Application r i..n: 2/8/17 City of Atlantic Beach \k ;/ 800 Seminole Road,Atlantic Beach,FL 32233 Phone:(904)247-5826 Fax:(904)247-5845 (�l Job Address: 1660 Atlantic Beach Drive Permit Number: geS O �Z l Legal Description Lot 150 Atlantic Beach Country Club Unit 2, Parcel #67-52 16-25-29E RE# 169505-2045 Valuation of Work(Replacement Cost)$395711 Heated/Cooled SF 3530 Non-Heated/Cooled 833 • Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): Commercial Residential • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: New home construction Florida Product Approval#seP attached for multiple products use product approval form Property Owner Information Name: Toll FL VI Limited Partnership Address: 160 Cape May Avenue City Ponte Vedra State FL Zip 32081 Phone 904-217-0739 E-Mail aregnier@tollbrothers.com Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Toll FL VI, LP Contractor Information Name of Company: Toll Bros., Inc Qualifying Agent: Steven R. Merten Address 160 Cape May Avenue City Ponte Vedra State FL Zip 32081 Office Phone 904-595-5243 Job Site/Contact Number 904-595-5243 State Certification/Registration# CGC1 510225 E-Mail aregnier@tollbrothers.com Architect Name&Phone# Toll Architecture(407)248-5800 Engineer's Name&Phone# Lou Pontigo&Associates(904)242-0908 Workers Compensation Policy#MWC30267702/Expries 9/1/2018 Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc.NOTICE:In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCI c ONSULT WITH YOUR LENDER OR AN ATTORN BEFORE RECORDING YOU• ICE OF COMMENCEMENT. (Sig a of Owner or Agent) 4 'ture of Contractor) (including contractor) Signed and sworn to(or affirmed)before me this QQ day of Signed and worn to(or affirmed)before me this day of , by SA"64. 1, f e Ore rkturin , )I T ,by SA-wee) l 0 "P_,✓1 _ (Si ature of No .ry) w Si:n.ire o Neta.) AUOREY N REGNIE/t „� :'"'"fie;: AUDREY N REGNIER r]Personally Knowri • [ Personally Known OR =� . .c MY COMMISSION M FF946t�1 Produced Identife , k.v ' OMMISSION*FF946tf1 [ ] patljxy;' [ ]Produced I icatioicatio :•y�� * EXPIRES ISSION K 21.20N Type of Identification''• ' EXPIRES O m*t 21201 Type of Identification: '�.°;,,��' (gm.; ,ir��i;-51..iCity of Atlantic Beach APPLICATION NUMBER S * Vit\ Building Department (To be assigned by the Building Department.) 800 Seminole Road «- Z61/Ce ,ii j .r, i Atlantic Beach, Florida 32233-5445 Phone(904)247 5826 • Fax(904) 247 5845 'r l c-•)' E-mail: building dept@coab.usJUL1 8 Date routed: ILL-p/ d City web-site: http://www.coab.us I BYE. APPLICATION REVIEW AND TRACKING FORM ( (� Q 141 ' c1 d ' De•artment review required Yes No Property Address: q euildis• Applicant: "MU B ro S • .• an n• & Zoning ree ••.• is ra or == Project: i n ( („ t,M t l k m- ublic W.rlc V • u. is Safety Fire Services _ Review fee $ Dept Signature ,'Tc/,\ Review or Receipt Other Agency Review or Permit Required Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: pproved. Denied. nNot applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: g(7/6. �1_`V `�`--- Date: 7 (1 C1- TREE ADMIN. Second Review: nApproved as revised. nDenied. nNot applicable PU: "WORKS Comments: BLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: nApproved as revised. nDenied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 j31..Altrr, City of Atlantic Beach APPLICATION NUMBER ., ' Building Department (To be assigned by the Building Department.) � 800 Seminole Road ` si Atlantic Beach, Florida 32233-5445 Ig4(e Phone(904)247-5826 • Fax(904)247-5845 ,: JUL 18 2018 L s �? E-mail: building-dept@coab.us Date routed: !lig it web-site: htt ://www.coab.us / C Y P ;-.4,, APPLICATION REVIEW AND TRACKING FORM Property Address: I(p(Q o f v \ t.cG Be, ' De•artment review required Yes No •uildia. Applicant: TO U B ro s • riannin• &Zoning == ree A.II. is ra or Project: Stn ( (., l FaM,[ ( L rrublic irk 7� • u. is Safety Fire Services , _ _L,),,:*: .vet ee , ;: .?- •.-.-1 ,,A-_,I.;:‘:-f• ,.4.'00:40 ?t — - Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. ['Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed b %ODate: 7_;/# 2 TREE ADMIN. Second Review: Approved as revised. ❑Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ['Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 City of Atlantic Beach olg.,,,,„ PUBLIC UTILITIES DEPARTMENT 1200 der AtlanticSanBeacpiph, FLaneL 32233 . (904)247-5834 NEW WATER/ SEWER TAP REQUEST Date 7 -/ '7 -/ 8 Project Address /(D (p 0 i77 - - ( ,l) r- Number of Units ! Commercial Residential ✓ Multi-Family New Water Tap(s) 34 '1 & Meter(s) Meter Size(s) w New Irrigation Meter Upgrade Existing Meter from to (size) New Reclaim Water Meter mr Size �9 New Connection to City Sewer Applicant Name Applicant Address City State Zip Phone Cell Email Applicant Signature CITY STAFF USE ONLY Application 4 2E5 18 - Q -`f(Q Water System Development Charge $ 1 110, 00 IV Cc Sewer System Development Charge $ 0 SO, `1 Water Meter Only $ • 0 Reclaim Meter Only $ m viii Water Meter Tap $ Sewer Tap $ Cross Connection $ 5O OD Other $ TOTAL $ S Co 10 I OD (Notes) APPROVED Kayle Moore, P.E. Date 7 It i/(i Public Utilities Director or Authorized Signature ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED MAP SHOWING PLOT PLAN OF LOT 150 AS SHOWN ON MAP OF ATLANTIC BEACH COUNTRY CLUB UNIT 2 AS RECORDED IN PLAT BOOK 67 PAGES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLA. CERTIFIED TO: TOLL BROTHERS, INC. $S BUILDERS ENDORSEMENT SIGNED: NAME. DATE: CURVE DATA Cl S59'27'25'E ALL PAVERS CH = 35.36' ALL MEASUREMENTS ESTIMATED R = 25.00' - FRONT 562* SQ. FT. A = 39.27' BACK 341* SQ. FT. = 90'00'00" s f P {J'�� r� `,P9 osf0 O __,,,,,*-_-_=:- - ._ \Nlfl COKs-c. -Hj/o"F-wn�l ' " x s- r�kAgf oeosE'o4. ' •i���;S%SpR % .- P c,,Ey.. pC1C? V�N fs 0 U,Y O GAS �.:r�A �Jy^ Tazo \ — P UN at'X',DI'I �,KGF$ 1 O l 1• \ OPOSEO . •rte f1 PR ER .G o o t '�i 7,1 \ "� CU EOM CE ..1...-2. ��a • a \ RE S0 �OPE1" Z ,1~ \ MIOOEWWs55.00 2 fr.=>1' v� P A \ r 069.50 O = O 13 _ X111.3) ti. £ $ _! \ .-0 :13 F•F•E' OSEO *—'etCs's` sA N .4'H irak"feitt i PRS 30) .r $ o: `t\\T' r��__ oscD 3,' F.E•" _o'o\ CPL- S° P,0 OTD F' c"IA Y ICK PAS PR Lp gWo� \ Q 10'JL \ TA lea ._�.ts+H Co 5 S$1 `. .\ Z ;N c co 1 o r=_t__ P 23 _ .> 00.31 \ 0 —S 6.. ---r... R $ 1 — = e'o Q '$ ,A \1 ---co — "WW 120.0 1 a — "/' 515 32 35 " OS %••' 5 A L 0 T --.,-DENOTES DIRECTION OF FLOW TYPE 'A' DRAINAGE ELEVATIONS SHOWN THUS (11.30) WERE TAKEN FROM ENGINEERING PLANS BY TAYLOR & WHITE, INC., DATED 04-15-14 DIMENSIONS SHOWN HEREON ARE PER FOUNDATION PLAN ELEVATIONS SHOWN HEREON REFER TO NAVE, OF 1988 LOT 150 MODEL'SAN TROPEZ' LOT SIZE 9,534* SQ. FT. DRIVEWAY TO R/W 317* SQ. FT. TREE SCHEDULE NOTE ALL UTILITIES SHOWN ENTRY WALKLOT SQ. FT. MINUS 180* SQ. FT. HEREON WERE FROM EASEMENTS/WETLANDS 9,534 APPROXIMATE SIDEWALK 839* SQ. FT. AS-BUILT DRAWINGS ACRES-9,534/43,560 0.22 RICHT-OF-WAY LENGTH 189.84 FT. PROVIDED BY CODY'S ACRESx40-REQUIRED TREE INCHES 8.8 PROFESSIONAL SURVEYING TOTAL IMPERVIOUS COVERAGE 3.670± SQ. FT. 39% AND MAPPING, INC. THE REQUIRED NUMBER OF TREE INCHES WILL BE MET TOTAL EASEMENT AREA SQ 12-18-14; JOB #10114 USING 2 DIAMETER TREES. 70%OF REQUIRED PLANTED TREES SHALL BE CANOPY TYPE, WITH NO MORE THAN 50X OF THE SAME SPECIES. THE LOT SHOWN HEREON IS IN THE SPECIAL FLOOD HAZARD ZONE le AS SHOWN ON LOMR-F CASE NO. 15-04-4216A DATED AWAY 4,2015 AS SHOWN ON FLOOD INSURANCE RATE IMP 0408 H FOR THE CITY OF JACKSONVILLE,FIORIOA DATED 06-03-13 ALL AMERICAN SURVEYORS OF FLORIDA, INC. LAND SURVEYORS-3751 5411 JOSE PEACE SUITE 15-J4CRSONNLL&FLORIDA.32237-904/279-0088-LICENSED LAND BUSINESS NO.3857 Leonid _ Il l.-- E Ew O 5 T AA En SKETCH FOR PLOT PLAN ONLY- DOES NOT REPRESENT OR PURPORT TO SHOW I - rmnoN BOUNDARY LINES NOR IS IT BASED ON A FIELD RUN SURVEY —4 CONC CONCRETE AFA - uE ELECTRIC YONM.. IRON P.T. -PIANOC1 a IRON ME Pio P.C?. NW. A,-KRIAANENT CONTROL PQNT ALL LL rOT a00 PG -RANT OF CUIM1E A OSA mai gzc.-PON,a.u... LVN.E AMERICAN A Mi�cTN P.C.C.-ROM OF COYP0OW cuavE SURVEYORS R RAMS DAL-NN»a RESTRICTION SURVEY NOT VNJD UNLESS EMBOSSED BY SEAL (0 C.) CALISLAND MAN--nRCM.POWER•WET OF FLORIDA, JAMES D. JR,No.28q INC. MICHAEL A.IL T,Na.66t3 RAT NQO-NATIONAL GEODETIC MM.. /�//�� R RAYL INE MTM SSE 1--JO• / IOC f cr TEx u+e xAo -NORMWOE AMERICAN�cxrcx _ _9 i/�' MOM-OF-RAT PLL .POINTOMA OF INTERSECTION FENCE OW .EDGE OF MIST ' _ M IMAM Toe -TOP OF PAN �� 03 29 18 REGISTERED SURVEYOR AND ER - _8 F.B. x OR ay BRI DIR, PI\2018\83754-182388-plotplan ORDER NO. 162388 v FILE 83754 fagt b //s e) REVOCABLE ENCROACHMENT AGREEMENT REVOCABLE ENCROACHMENT AGREEMENT by the City of Atlantic Beach,Florida,a municipal corporation organized and existing under the laws of the State of Florida,hereinafter referred to as"CITY"and TOLL FL VI,LP of Atlantic Beach,Florida,hereinafter referred to as"USER". WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property for the purpose as described in the City of Atlantic Beach. This work is generally described as Pavers in the Right-of-Way for the driveway. Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty (30) days' notice by CITY to USER, said notice to USER shall be given by certified mail, return receipt requested,to the following address 1660 Atlantic Beach Dr' Parcel#67-132 08-2S-29E . • In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above described easement or property of the CITY,the USER shall replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining,repairing,operating,replacing or adding to of the utilities and facilities of the CITY or franchise utility provider. • The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes, Land Development Code and all other land use and code requirements of the CITY,including City Code Section 19-7(h) which states"Driveways that cross sidewalks: City sidewalks may not be replaced with other materials, but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." • The USER,prior to making any changes from the approved plans and/or method,must obtain written approval from the City of Atlantic Beach Public Works Department,for said change within 30 days after the day of completion. • This permit shall inure to the benefit of,and be binding upon,the USER and their respective successors and assigns. • USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications,to include utilities locate requirements and use limitations/requirements of easements, public right- of-ways and other Iublic land. USER further agrees that the CITY and its officers and employees shall be saved harmless by the d R from any of the work herein under the terms of this permit and that all of said liabilities are hereby assui s the USER. ,/ 40 Date > 7'fitr Property Ow 1 •r/A 1 • ? (signed in presence of Notary Public) STATE OF FLORIDA,COUNTY OF DUVAL The foregoing instrument was acknowledged this a-I day of a ircil ,20 1 F , by SkeVey\, MP.A(;-'•e,V1 ,who personally appeared before me and (printed name of Signer) acknowledged that he/she signed the instrument voluntarily for the pu 'ose e • • •a •a ` AUDREY N REGNIER '` MY COMMISSFON$FF446491 J '4•.!t EXPIRES December 28.2019 Signature of otary Public, tate of Florida '' °s � t Jyn4VW fKO OU / Department Approval: V- _Known (/ - Produced Identification(Type) . � //di_ _ i .1 j / . Scott Wi tams, 'ubltc or I ector/ Kayle Moore,Public Utilities Director H:\Master Forms\Public-Utilities Works Forms\Revocable Encroachment Agreement 2.5.18.docx Revision Date:2/5/18 ti's RIGHT-OF-WAY / EASEMENT PERMIT 4,11)11`> Permit#Issued by the City of Atlantic Beach PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES Job Address 1660 Atlantic Beach Drive Phone 904-595-5243 Permittee Steven Merten Email aregnierAtollbrothers.com Requesting Permission to Construct Pavers in the Right of Way for the driveway Location(Reference to Cross-Street) Coastal Oak Lane&Atlantic Beach Dr. -06884 ATLANTIC BEACH COUNTRY CLUB UNIT 02 • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement,maintenance,safe and efficient operation, alteration or relocation of all,or any portion of said street or easement as determined by the Director of Public Works,any or all said poles,wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of Stacia Moore (Project Superintendent) located at 237 9th Avenue North,Suite 4,Jacksonville Beach,FL 32250 • All materials and equipment shall be subject to inspection by the Director of Public Works. • All city property shall be restored to its original condition as far as practical, in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • The permittee shall commence actual construction in good faith within days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,title and interest in the land to be entered upon and used by the holder,and the holder will,at all times, assume all risk of and indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and • 'vileges. • The Director of Pub ' forks shall be notified twenty-four(24)hours prior to starting work and again immediately upo• •P,pletion. �� Date Af/i Permittee: Steven '. e/01 ,Division President,TOLLFL VI,LP(signed in presence of Notary Public) STATE OF FLO DA,COUNTY OF SAINT JOHbA., The foregoing instrument was acknowledged this 1 day of MQ'l,rC,h ,20 IS' , by JA-e' \ Merl-R.. V\ ,who personally appeared before me and (printed name of Permittee) ackn•wledged that he/she signed the instrument voluntarily for the purpose expressed in it. 0 , ,^ � , rl Personally Known /// Signature et:AJ_ :, Pi'biir,Stmt f Flr,rirla Produced Identification(Type) ...:ill'::,, AUDREY N REGNIER MY COMMISSION#FF948491 .?'o,•t. EXPIRES December 28,2019 Tauri i9e.010 Florfoayotart6a.v,y corn 5IANf City of Atlantic Beach APPLICATION NUMBER �, ,f'r.? Building Department (To be assigned bythe BuildingDe artment. � 800 Seminole Road Q g 18's." Department.) j . , Atlantic Beach, Florida 32233-5445 /�ES!8'✓ 6 Z 4(e Phone(904)247-5826 • Fax(904)247-5845 / -..fin �. E-mail: building-dept@coab.us Date routed: ! City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: I (QLQ 0 C Qivi\`c. Be, ' D e•artment review required Yes No II •uildii Applicant: -b a ro s • rilannin• &Zoningree A . Project: i n j( e.., F,M t f ` ,rublic •I. isJIMMIMill ra oor == QMODIMMIIMIIII liegaz Fire Services _ Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection — Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ['Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by:, ---- Date: 7-1 -18- TREE —I -1eTREE ADMIN. Second Review: A roved as revised. Denied. ❑ pp ❑ ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 1 OFFICE CC~ PERMITTED BUILDING DATA DO NOT WRITE BELOW — OFFICE USE ONLY Applicable Codes: 6th Edition (2017) Florida Building Code DEVELOPMENT SIZE: Habitable Space (ft') 35-0 el Non-Habitable Space (ft') ' 2 LAND INFORMATION: Zoning District �L G Flood Zone X Minimum FFE 11, 30 ' l ptcl. 3a BUILDING INFORMATION: Construction Type V Occupancy Group Stosi-+ +-ami Number of Stories Max Occupancy Load Fire Sprinklers Required V CONDITIONS/ COMMENTS: Rev. 2.7.2018 MAP SHOWING PLOT PLAN OF LOT 150 AS SHOWN ON MAP OF ATLANTIC BEACH COUNTRY CLUB UNIT 2 AS RECORDED IN PLAT BOOK 67 PAGES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUAL COUNTY, FLA. CERTIFIED TO: TOLL BROTHERS, INC. :UILDERS ENDORSEMENT SIGNED. OFFICE COPY CURVE DATA C1 ATE AME: 959'27'25'TALL PAVERS CH •., 35.36' R = 25.00' A = 39.27' ALL MEASUREMENTS ESTIMATED FRONT 562± SQ. FT. BACK 341± SQ. FT. A = 90'00'00' nR4° fea .c 1..0 .y1 E -Nike" (50 `FrivyrjC •... it`Yi'`-'� TSU P A,x4 P05E0 MI'RPP PITC.Pre C 9P)G%w,1 r rr J .'v �.k�9) Cp A05 w1 . 0. �• pG!L-'p" '''''���m�ScaEE' OA =s '� *IA i"s 51 0 613`GE '�L 5 ��'{5(,., it ti•Z P 'St PR�CONNEI OH o [_ �z$ O. c 0 1, PROP OTHER 2 , . k \1 REg0E14CE0PEZ . •., T� ti's N,ODEL 5 ,.. 20.. S p I r01. O 73 -t 's;�:r?%'moo F• PROP`2 30) jE`�f.�-," mr" • m`SA > PPOP 6L o f.FEm co 71 Cr„Awl. Tn r C 1 .. BpICK Pew S, J.VERE ,00 w \ TOILET . O 1 O y r..%'. PAYER EN .\ Z3.,1. _ L' o &-+I s�' 4 i i C{; • F P n ..I - 1 I. 510 i �'' O PtT$ 10?1 1 b. —5:B.R.4 -' °' 11 —rn ' •' 120 p0 ▪. $1� 1 0 5+W A Lam' r 575323 • bi.ra Io Atop 5 L O T 1 --^-DENOTES DIRECTION OF FLOW TYPE"A" DRAINAGE ELEVATIONS SHOWN THUS (11.30) ' WERE TAKEN FROM ENGINEERING PLANS BY TAYLOR &WHITE, INC., DATED 04-15-14 DIMENSIONS SHOWN HEREON ARE PER FOUNDATION PLAN ELEVATIONS SHOWN HEREON LOT 150 REFER TO NAVD OF 1988 MODEL"SAN TROPEZ" LOT SIZE 9,534± SQ. FT. DRIVEWAY TO R/W 317± SQ. FT TREE SCHEDULE ENTRY WALK 180± SQ FT NOTE ALL UTILITIES SHOWN LOT SQ. FT. MINUS EASEMENTS WETLANDS 9,534 HEREON WERE FROM EASEMENTS/ WETLANDS SIDEWALK 8391 SQ. FT. AS-BUILT DRAWINGS ACRES=9,534/43,560 0.22 RIGHT-OF-WAY LENGTH 189.84 FT PROVIDED BY CODY•S ACRESx40-REQUIRED TREE INCHES 8.8 PROFESSIONAL SURVEYING TOTAL IMPERVIOUS COVERAGE 3,670* SQ. FT. 39% AND MAPPING. INC. THE REQUIRED NUMBER OF TREE INCHES WILL BE MET TOTAL EASEMENT AREA Ot SQ FT. 12-18-14; JOB #10114 USING 2"DIAMETER TREES. 70%OF REQUIRED PLANTED TREES SHALL BE CANOPY TYPE, WITH NO MORE THAN 50%OF THE SAME SPECIES. THE LOT SHOWN HEREON IS IN THE SPECIAL FLOOD HAZARD ZONE"X"AS SHOWN ON LOMR-F CASE NO. 15-04-4216A,DATED MAY 4,2015 AS SHOWN ON FLOOD INSURANCE RATE MAP 0408 H FOR THE CITY OF JACKSONVILLE,FLORIDA, DATED 06-03-13 ALL AMERICAN SURVEYORS OF FLORIDA, INC. LAND SURVEYORS-3751 SAV JOSE PUC£ SUITE 15-JACKSONVILLE, FLORIDA. .72257-904/279-0088-LICENSED LAND BUSINESS NO..7857 Leaend COV. COVERED MC-fmsN nooP ETFVAnON _ g CND. Pauxo A/C -SP c;lunar/ FOR PLOT PLAN ONLY-DOES NOT REPRESENT OR PURPORT TO SHOW E T EASEUENr IG. -Gem/ BOUNDARY LINES NOR IS IT BASED ON A FIELD RUN SURVEY =q upon. aNuunExr 'A -Acxvo,mUE EIECONC - GNITy LA wo PIPE P.T. -PoviT a Tgli21 ALL P.Cr.-PEAUSIFN}COryiNCt PaiNT A DATA SIDLE P.C. -POI/OF CUM CN CNORD P.N.C.-PONT OF PMPSE CUNrE AMERICAN A MC LENGTH P.C.C.-POINT OF CONPOUNO D1000 R Tows P d-eunnuw PmwcnoN ' SURVEY NOT VALID UNLESS EMBOSSED BY SEAL SURVEYORS (cuc.) F./F./ATM PFJi-RwuM PONEA t ucn OF FLOR/DA, G GEED OW.).LTPiCAI JAMES D.HARRISON.JR.,No.2647 )) MICHAEL A.GARRETT,No.66t3 INC. N) MGNL one NGw-„T&GEOOLTC WPM, /♦ £ CO001 UNE NAND -DATuu NuMIGW NERICAL WN SCALE l' 3°. 5''!"`�p ✓W -NIGH"-GF-.AY Ill POYII OF WTFASECnOH //� —J •'` o'N -EDGE OF AMA v - 00 .MINESc Toe -lap of emf PATE 03-29-18 D REGISTERED SURVEYOR AND R _B F.B. X DR,BY BRB - DIR. P:\2018\83754-162388-plolplon ORDER NO. 162388 FILE 83754 MAP SHOWING PLOT PLAN OF LOT 150 AS SHOWN ON MAP OF ATLANTIC BEACH COUNTRY CLUB UNIT 2 AS RECORDED IN PLAT BOOK 67 PAGES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUAL COUNTY, FLA. CERTIFIED TO: TOLL BROTHERS, INC. _BUILDERS ENDORSEMENT SIGNED: NAME: DATE: CURVE DATA Cl S5927'25`E ALL PAVERS CH R: 35.36' ALL MEASUREMENTS ESTIMATED R = 25.00' FRONT 562± SQ. FT. A R 39.27' BACK 3411 SQ. FT. • A = 90'00'00" rr�� •OR �E- • �`RB Fy�fO Cop,5�A c O< `.tAV a ��er • . I4Crp PFOPO —� pROPOREjt�:+"' ? - - -2-% 7c r.ove4,0.1 3 J * S 5\0 Iwo CAR `rt'4 GPRA'EE 0 • c t 0'1'0'44 acosEDX',&4 S o 1 Aµ01• UNE coN vt111 x$o �. RES\OEN OPE. N yt; • 0 7� Z q MODEL W:5.p0� 2°:* f 5 1 f 6 p r N9. 0` 9530) �3 ✓ 73 _, ` O SS (11. 4 tv, Q1 n ` f3:s o • F PRS X 30) 11.5.0\ 9, a1 PROP PED s F,F.E• 0 moo c1• r 5R COVEppyEµ9� -,opos°,c6 - \ 0 1d1ET E\ 3N BRICK..�y= COA.&EN • vFR00 RR'L iP_p CO O ..s:=SS.�iK p 1 23.2 7 . o t��. + 3 -.1IP \ t:615:412 .'.. .'_ 9\0. _.��� •I vny CO gq. oti —a '-4 120.0" ;:%,,„ A'�� — 1 -- O IPW ..�x f' `�,��f— 575.3236 ,Loo 5 1 A L 0 T COMMUNITY DEVELOP OTES DIRECTION OF FLOW �A//�'.�( �E"A' DRAINAGE • , `®�� LANS YTAYLOR &TAKEN F WHITE, INC, DATEDROM ENGINEERING 04-15-14 DIMENSIONS SHOWN HEREON ARE PER FOUNDATION PLAN ���,,,••/// ELEVATIONS SHOWN HEREON LOT 150 REFER TO NAVD OF 1988 MODEL'SAN TROPEZ- LOT SIZE 9,534± SQ. FT. DRIVEWAY TO R/W 317± SQ. FT. TREE SCHEDULE ENTRY WALK 180± SQ. FT. NOTE ALL UTILITIES SHOWN LOT SQ. FT. MINUS HEREON WERE FROM EASEMENTS/WETLANDS 9,534 APPROXIMATE SIDEWALK 839± SQ. FT. AS-BUILT DRAWINGS ACRES9,534/43,560 0.P2 RIGHT-OF-WAY LENGTH 189.84 FT. PROVIDED BY CODY'S ACRESx40=REQUIRED TREE INCHES 8.8 PROFESSIONAL SURVEYING TOTAL IMPERVIOUS COVERAGE 3,670± SQ. FT. 39% AND MAPPING, INC. THE REQUIRED NUMBER OF TREE INCHES WILL BE MET TOTAL EASEMENT AREA 0± SQ. FT. 12-18-14; JOB #10114 USING 2"DIAMETER TREES. 70%OF REQUIRED PLANTED TREES SHALL BE CANOPY TYPE, WITH NO MORE THAN 50X OF THE SAME SPECIES. THE LOT SHOWN HEREON IS IN THE SPECIAL FLOOD HAZARD ZONE'X'AS SHOWN ON LOMR-F CASE NO. 15-04-4215A.DATED MAY 4,2015 AS SHOWN ON FLOOD INSURANCE RATE MAP 0408 H FOR THE CITY OF JACKSONVILLE,FLORIDA, DATED 06-03-13 ALL AMERICAN SURVEYORS OF FLORIDA, INC. LAND SURVEYORS-3751 SW JOSE PLACE,SUITE 15-J4CKSOIMLLE fLORJLLI,32257-904/279-0088-LICENSED LAND BUSINESS NO.3857 cw. catrao EPA..FIRMA noon=VAR. I-7:1:I 4I rNo. rain c - oTTaNTR SKETCH FOR PLOT PLAN ONLY-DOES NOT REPRESENT OR PURPORT TO SHOW E0Y'T 000000 E A -IDEMInuOOr' BOUNDARY LINES NOR IS IT BASED ON A FlEID RUN SURVEY COM CONCRETE JFA -40150101E E1Ecmc YON. 1.101/.101.101/.1011 OUORTY IRON ON PIPE P.T. .PORI OF IM,CfRCV ALL I.R. WON ROU ..CP.-PERYWEM CORD.POHR A 0(1TA MOIL P.R .C. POww OF Colo SE QRNE , a #LOD AMERICAN A ARC IENOIR P.C.C..Pani OF COMPOUND CURVE • . R RADIUS B.Rl.BOWING RESRCIION SURVEY NOT VALID UNLESS EMBOSSED BY SEAL SURVEYORS '(CI o 110 P -no0n1 POWER.LIGHTOF FLORIDA,. . J1 )- JAMES D.HARRISON JR.,No.2647 INC. R PLAT UAE ' NORTH crattTx SERAIL MICHAEL A.OARflET'f.No.6643/ Z -cuncR unE w.w.ROWWRY..--. vmTTnL SCALE 1• 1f!'�lD R/W - M-OF-WAV P.I. .PONT Or INTFRSECRON //*_-/ All —g rL4CE EDW .MOE OF WATER (0) -000000 TOO -TDP of RAWGATE 03-29-18 1-ID REGISTERED SURVEYOR AND •SLR _8 F.B. X DR. By BRIT D1R. P.\2018\83754-162388-plolplon irORDER NO, 162388 ir ALE 83754 S a /.P o f ricric . FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION , Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: San Tropez 3530 Right NE Builder Name: Toll Brothers Street: Lot 150 Atlantic Beach CC Permit Office: Duval City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Toll Brothers Jurisdiction: 261300 Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(3845.3 sqft.) Insulation Area • a.Frame-Wood,Exterior. R=19.0 3543.70 ft2 • 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 301.67 ft2 3. Number of units,if multiple family . 1 c.N/A R= ft2 2 4. Number of Bedrooms 4 d.N/A / R= 10.Ceiling Types (2423.0 sqft.) Insulation Area 5. Is this a worst case? No . a.Under Attic(Vented) R=38.0, 2114.00 ft2 6. Conditioned floor area above grade(ft2) 3529 b.Under Attic(Vented) R=19.0 309.00 ft2 c.N/A R= ft2 Conditioned floor area below grade(ft2) 0 11.Ducts R ft2 7. Windows(470.6 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 415 a. U-Factor. Dbl,U=0.34 470.56 ft2 b.Sup: Attic,Ret:Attic,AR:2nd Floor 6 209 SHGC: .SHGC=0.27 • 12.Cooling systems • kBtu/hr Efficiency b. U-Factor. N/A ft2 a.Central Unit 42.0 SEER:14.00 SHGC: . b.Central Unit 18.0 SEER:14.00 c. U-Factor. N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.20 SHGC: b.Electric Heat Pump 18.0 HSPF:8.20 Area Weighted Average Overhang Depth: 3.691 ft. 14.Hot water systems Area Weighted Average SHGC: 0.270 a.Natural Gas Tankless Cap:1 gallons 8. Floor Types (3529.0 sqft.) Insulation Area EF:0.800 a.Slab-On-Grade Edge Insulation R=0.0 2305.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 1106.00 ft2 None c.other(see details) R= 118.00 ft2 15.Credits Pstat , Total Proposed Modified Loads: 86.92 .. ,. PASS Glass/Floor Area: 0.133 Total Baseline Loads: 92.70 I hereby certify that the plans and specifications covered by Review of the plans and00 e............• AT., this calculation are in compliance with the Florida Energy specifications covered by this +F .'••;"(4i<7,+= '� ; ;-.94, Code. calculation indicates compliancevo r�kQ'•:)i„ ' ,*�-_ _,.,o``�..: with the Florida Energy Code. /r prow. '', ::_ '°' ,\ O PREPARED BY:„. ,. ..--e-.4^U1LD9Z AI/4 7`%iVo-rho Before construction is completed i 4 _ ;• � d i. DATE: this building will be inspected for .c�. _.7 ; compliance with Section 553.908 * �` . u :i 2r a • Florida Statutes I hereby certify that this building,as designed, is in compliance .. N.�, ‘11 . 0 with the Florida Energ Code. 'I,a ' W� �'`� '„��truss..N.rOf OWNER/: NT: a A - BUILDING OFFICIAL: / fil DATE: 0 1N. DATE: 1.,-1,/..,8..... '/'.,� - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 7/5/2018 4:14 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 OFFICE COPY PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA Project Name: Toll Brothers,Inc. Permit# Q&S l5 Ua 9 g Project Address: 1660 Atlantic Beach Drive Lot 18 As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at:www.floridabuilding.org. Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A. EXTERIOR DOORS 1. Swinging Masonite Wood Edge,Steel N/A Double-FL8228.6 Single-FL6506.4 Simpson Door Company Wood Door FL 14487.1 Therma-Tru Fiberglass/Wood Door N/A FL 5262.3 2. Sliding PGT 2500 Aluminum Slide Glass +25/-25 FL 251 3. Sectional +43.2/-49.6 8 ft FL 9174.12 Wayne Dalton Section Ext.Door +39.2/-43.7 16ft FL 9174.15 4.Roll up 5.Automatic 6. Other B. WINDOWS 1. Single Hung PGT 5400 Vinyl Single Window +50/-50 FL 1435 2. Horizontal slider PGT 5400 Vinyl Hor.Window +50/-50 FL 1844 3. Casement 4. Double hung 5. Fixed PGT 5400 Vinyl Fixed Window +50/-50 FL 5012 6.Awning 7.Pass-through 8.Projected 9.Mullion PGT Alum/Vinyl Mullions N/A FL 261 10.Wind Breaker 11. Store Front/Mitred Glass Kawneer Glass Windows Mitred Glass Windows +30/-30 FL 10008.1 12. Glass Block US Block/Hy-Lite Glass Block Window 70 PSF FL 185.12 lm r. "i Category/Subcategory Manufacturer Product Description Limitation of Use afc Local # C.PANEL WALL 1. Siding James Hardie Building Products,Inc. Lap Siding and Shingle Panels N/A FL 13192.2; 13192.4 James Hardie Building Products,Inc. Lap Siding and Shingles N/A FL 10477.1 FL 12098.3; 12098.1; Nichiha Corp. Lap Siding and Shingles N/A 12875.1 2. Soffits/Ceilings James Hardie Building Products,Inc. Soffit Panels N/A FL 13265.1 Nichiha Corp. Soffit Panels N/A FL 12098.4 3.EIFS 4. Storefronts Kawneer Glass Windows Mitred Glass +30/-30 FL 10008.1 5.Curtain walls 6.Wall louvers 7.Glass block 8.Membrane 9.Greenhouse 10.Synthetic Stucco 11.Other D. ROOFING PRODUCTS 1.Asphalt shingles GAF Corp. Timberline 30 year Arch Shingles N/A FL 10124.1 2.Underlayments Woodland Industries,Inc. Felt N/A FL 1814.12 Boral Roofing Roof Underlayment N/A FL 14317.1 3.Roofing fastners 4.Nonstructural metal roof \liIlennium \letals,Inc. Metal Roofing-M seam N FL 5211.3 R6 5.Built-up roofing 6.Modified bitumen 7. Single ply roofing 8.Roofing tiles 9.Roofing insulation 10. Waterproofing 11.Wood shingles/stakes Watkins Sawmill LTD. Wood Shingles and Shake NiA FL 13714.1 12.Roofing slate 13. Liquid applied roofing 14.Cement-adhesive coats 15.Roof tile adhesive 16. Spray applied polyurethane roof 17.Other MI-Deck Walking deck membrane N/A FL 12407.1 Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# E. SHUTTERS OFFICE COPY 1.Accordion 2.Bahama 3. Storm panels Town and Country Industries Storm shutters N/A FL 11963 4.Colonial 5.Roll-up 6.Equipment 7.Other F. STRUCTURAL COMPONENTS 1.Wood connector/anchor Simpson Strong Tie Per engineering 2.Truss plates Alpine Engineered Truss plate conn. Per engineering 3.Engineered lumber Georgia Pacific Eng.Lumber FL 2023.1 4.Railing 5.Coolers-freezers 6.Concrete admixtures 7.Material 8.Insulation forms 9.Plastics 10.Deck-roof 11.Wall 12. Sheds 13.Other G. SKYLIGHTS 1.Skylight Sun Tek FGC Skylite FL 2442 2.Other H.NEW EXTERIOR ENVELOPE PRODUCTS 1 7/16"Zip Wall-Structural 1 OSB(roof and wall);manufacturered by Huber Engineered Woods 2 In addition to completing the above list of manufacturers,product description and State approval number for the products used on this project,the Contractor shall maintain on the job site and available to the Inspector,a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the oc C I COPY listed in this document must be approved by the Building Official. ��""(- Audrey Regnier I6t (Contractor Name) (Print Name) (Si ature) Company Name: Toll Brothers,Inc. Mailing Address: 160 Cape May Avenue City: Ponte Vedra State: FL Zip Code: 32081 Telephone Number: 904 217-0739 Fax Number: Cell Phone Number: 904-405-8969 Email Address: aregnier@tollbrothers.com 0* ICECIERYOFFICE COPY FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation Residential Performance Method Project Name: San Tropez 3530 Right NE Builder Name: Toll Brothers Street: Lot 150 Atlantic Beach CC Permit Office: Duval • City,State,Zip: Atlantic Beach,FL, Permit Number: , Owner: Toll Brothers Jurisdiction: 261300 Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) • 1. New construction or existing New(From Plans) 9. Wall Types(3845.3 sqft.) Insulation Area • a.Frame-Wood,Exterior. R=19.0 3543.70 ft2 . • 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 301.67 ft2 3. Number of units,if multiple family . 1 c.N/A R= . ft2 ' 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types(2423.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0, 2114.00 ft2 • 6. Conditioned floor area above grade(ftz) 3529 b.Under Attic(Vented) R=19.0 309.00 ft2 • c.N/A R= ft2 Conditioned floor area below grade(ft') 0 11.Ducts R ft2 7. Windows(470.6 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:2nd Floor . 6 415 a. U-Factor: Dbl,U=0.34 470.56 ft2 b.Sup: Attic,Ret:Attic,AH:2nd Floor 6 209 . • SHGC: SHGC=0.27 b. U-Factor: N/A " ftz • 12.Cooling systems . kBtu/hr Efficiency , a.Central Unit 42.0 SEER:14.00 SHGC: b.Central Unit 18.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 42.0 HSPF:8.20 SHGC: b.Electric Heat Pump 18.0 HSPF:8.20 Area Weighted Average Overhang Depth: 3.691 ft. Area Weighted Average SHGC: 0.270 . 14.Hot water systems a.Natural Gas Tankless Cap:1 gallons 8. Floor Types (3529.0 sqft.) Insulation Area EF:0.800 • a.Slab-On-Grade Edge Insulation R=0.0 2305.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 1106.00 ft2 None c.other(see details) R= 118.00 ft2 15.Credits Pstat Total Proposed Modified Loads: 86.92 PASS Glass/Floor Area: 0.133 Total Baseline Loads: 92.70 I ','goo.....,,e,i, , I herebycertifythat theplans and specifications covered byReview of the plans and e404.t tifE STAT+'v, P a....•; ... v. this calculation are in compliance with the Florida Energy specifications covered bythis 4ti 1• a �,F o 4; Code. calculation indicates compliance A u4.,•i„�W '; •*!._;,,;,,���:�? � _ �! with,the Florida Energy Code. !~ mir• e'; n.Q is PREPARED BY:td/.- 0ZZrG"v'td/�rJw4-rho Before construction is completed 1 •• r-17:-d . "�` C7 3' DATE: this building will be inspected for • €o; 11i1 l:r. j,h Y compliance with Section 553.908 * •... .. /* I hereby certify that this building,as designed, is in compliance Florida Statutes... Ni 4,',1** .• .• y,C,3 with the Florida Energ.}Code. • ,,QOD NT of / l.�...x...mio OWNER/A NT: �. "L( �` -•h BUILDING OFFICIAL: / t DATE: - l(O -Jr` , DATE: - ?... • /r • - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). . 7/5/2018 4:14 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT .• Title: San Tropez 3530 Right NE Bedrooms: 4 Address Type: Street Address 1Lot# Building Type: User Conditioned Area: 3529 Owner Name: Toll Brothers Total Stories: 2 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Toll Brothers Rotate Angle: 0 Street: Lot 150 Atlantic Beach Permit Office: Duval Cross Ventilation: No County: Duval Jurisdiction; 261300 Whole House Fan: No City,State,Zip: Atlantic Beach, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: • • ' CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range V FL,Jacksonville FL_JACKSONVILLE_INT 32 93 70 75 • 1281 49 Medium • BLOCKS Number Name Area Volume • 1 Biockl 2305 23050 .2 Block2 1224 11016 • SPACES . Number Name . Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main •2305 23050 Yes 2 1 1 Yes Yes Yes 2 2nd Floor 1224 11016 No 3 3 1 Yes Yes Yes FLOORS I� # Floor Type Space Perimeter Perimeter R-Value Area s Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 187 ft 0 2305 ft2 ____ 0 0 1 2 Floor over Garage 2nd Floor __r 118 ft219 0 0 1 3 Floor Over Other Space 2nd Floor --- ____ 1106 ft2 0 0 0 1 ROOF Roof Gable Roof Solar. . SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) i./ 1 Gable or shed Composition shingles 2710 ft2 606 ft2 Medium 0.6 N 0.9 No 0 26.6 - ATTIC --V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC ✓ 1 Full attic Vented 300 2423 ft2 N N 7/5/2018 4:14 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 I FORM R405-2017 CEILING /.) # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type '- 1 Under Attic(Vented) 2nd Floor 38 Blown 1069 ft2 0.11 'Wood • 2 Under Attic(Vented) Main 38 Blown 1045 ft' 0.11 .Wood 3 Under Attic(Vented) Main 19 Blowni 154 ft2 0.11 Wood 4 Under Attic(Vented) 2nd Floor 19 Blown 155 ft' 0.1.1 Wood 1 WALLS AdjacentCavity Width Height Sheathing.Framing Solar Below J# Orvt To Wall Type Space R-Value Ft Ft In Area P.-value Fraction Ahsor (rade% 1 NE Exterior Frame-Wood 2nd Floor 19 • 35 4 9 0 318.0 ft' 0 0.23_ . 0.6. 0 .2. NE Exterior Frame-Wood Main . 19 24 . 10 10 0. 248.3 ft' 0 • 0.23 0.6 0 3 SE Exterior Frame-Wood 2nd Floor 19 47 0 9 0 423.0 ft' 0 0.23 0.6 0 4 SE Exterior .• Frame-Wood Main . 19 63 2 10 0 631.7 ft' . 0 0.23 0.6 0 5 SW Exterior Frame-Wood 2nd Floor 19 35 4 9 0 318.0 ft' 0 0.23 • 0.6 0 6 SW Exterior Frame-Wood Main 19 55 0 10 0 550.0 ft' 0 0.23 • 0.6 0 NW Exterior Frame-Wood V8 2nd Floor 19 47 0 9 0 423.0 ft' 0 0.23 0.6 0 NW Exterior Frame Wood Main 19 63 2 10 0 631.7 ft' 0 0.23 0.6 0 9 NE Garage Frame-Wood Main 13 30 2 10 0 301.7 ft' 0 , 0.23 0.01 0 DOORS V # Ornt Door Type Space Storms U-Value FtWidth Height Area In Ft In ./ None .4 3 8 24 ft' 1 NE Wood Main 2 NE Wood Main None .4 2 8 8 21.3 ft2 • • WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NE 1 • Vinyl Low-E Double Yes 0.34 0.27 N 15.0 ft' 1 ft 4 In 1 ft 0 in Drapes/blinds Interior 5 2` SW 6 Vinyl Low-E Double Yes 0.34 0.27 N 128.0 ft' 10 ft 0 in 1 ft 0.in None Interior 5 3 NE 2 Vinyl Low-E Double Yes 0.34 0.27 N 8.0 ft' 1 ft 4 in 1 ft 0 in None Interior 5 4 NE 2 Vinyl Low-E Double Yes 0.34 \ 0.27 N 52.5 ft2 1 ft 4 in 1 ft 0 in• None Interior 5 • 5 NE 2 Vinyl Low-E Double Yes 0.34 0.27 N 6.0 ft' 1 ft 4 in 1 ft 0 in None Interior 5 '6' SW. 5 , Vinyl'--Low-E Double • Yes -• 0.34 0.27 N 40.0 ft2 1 ft 4'in 1 ft 0 in Drapes/blinds Interior:5 7 SW 6 Vinyl Low-E Double Yes 0.34 0.27 N 36.0 ft' 1 ft 4 in 1 ft 0 in .Drapes/blinds Interior 5 8 SW 6 Vinyl Low-E Double Yes 0.34 0.27 N 36.0 ft' 1 ft 4 in 1 ft 0 in None Interior 5 9 SE 4 Vinyl Low-E Double Yes 0.34 0.27 N 36.0 ft' 1 ft 4 in 1 ft 0 in None Interior 5 10 SE 4 Vinyl Low-E Double Yes 0.34 0.27 N 52.5 ft' 1 ft 4 in 1.ft 0 In Drapes/blinds Interior 5 11 NE 1 Vinyl Low-E Double Yes 0.34 0.27 N 12.0 ft' 1 ft 4 in 1 ft 0 in None . Interior 5 12 NW 8 Vinyl Low-E Double . Yes 0.34 0.27 N 20.0 ft' 1 ft 4 in 1 ft 0 in None Interior 5 13 NE 1 Vinyl Low-E Double Yes 0.34 0.27 N 9.0 ft' 1 ft 4 in 1 ft 0 in None Interior 5 \ 14 SW 5 Vinyl Low-E Double Yes 0.34 0.27 N 3.6 ft' 1 ft 4 in 1 ft 0 in None Interior 5 7 15 NW 7 Vinyl Low-E Double Yes 0.34 0.27 N 16.0 ft' 1 ft 4 in 1 ft 0 in Drapes/blinds Interior 5 i I 7/5/2018 4:14 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 GARAGE ✓ # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation tJ 1 440 ft2 440 ft2 56 ft 9 ft • 1 , INFILTRATION # Scope Method. • SLA . .CFM 50 ELA. EgLA. ACH ACH 50 1 Wholehouse Proposed ACH(50) '.000429 3974.4 218.19 410.33 .407 7 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.2 42 kBtu/hr . 1 sys#1 / 2 Electric Heat Pump/ Split HSPF:8.2 18 kBtu/hr 2 sys#2 • COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts • .// 1 Central Unit/ Split SEER:14 42 kBtu/hr 1260 cfm 0.8 . 1 sys#1 / 2 Central Unit/ Split . SEER:14 18. kBtu/hr _ 540 cfm 0.7 2 sys#2 HOT WATER SYSTEM ✓ # System Type SubType Location EF Cap Use SetPnt Conservation V,- Natural Gas Tankless Exterior 0.8 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM •• . ✓ FSEC Collector Storage • Cert # Company Name System Model# Collector Model# Area • • Volume.. FEF None None ft2 DUCTS V ----Supply— --Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool • 1 Attic 6 415 ft2 Attic 86 ft2 Default Leakage 2nd Floor (Default) (Default) 1 1 �� 2 Attic 6 209 ft2 Attic 90 ft2 Default Leakage 2nd Floor (Default) (Default) 2 2 • 7/5/2018 4:14 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 I i FORM R405-2017 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling [[ ]]Jan [[ Feb] ( Mar [[ ]]Apr I ]]May ((X Jun [[X]]Jul [[X]]Aug" [[X]Se [ ]Oct [ Nov [ ]Dec Heating [X]Jan [X]Feb (XI Mar [ )Apr [ ]May [ t Jun [ )Jul E']Augg [ ]Se []Oct [X�Nov [X]Dec Venting [[ ]]Jan [[ ]Feb [X Mar [[XX])Apr [[[[ ]]May [[ Jun [[ ]]Jul ]]Au [[ ]]]Sep [X]Oct [X Nov [ )Dec Thermostat Schedule: HERS 2006 Reference 1 Hours Schedule Type 1 2 ,3 • 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 80 78 78. 78 78 78 78 8 78 78 80 78 800 78 Cooling(WEH) PM 78 78 78 78 78 78 78 8 78 8 78 78 78 78 Heating(WD) AM 66 66 ' 66" 66 66 "'68 68 68 68 68 68 68' PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 68 66 68 68 68 68 8 68 68 •66 • i i 7/5/2018 4:14 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2017 . ENERGY PERFORMANCE LEVEL (EPL_) DISPLAY CARD . ESTIMATED ENERGY PERFORMANCE INDEX* = 94 " • The lower the EnergyPerformance Index,the more efficient the home. Lot 150 Atlantic Beach CC, Atlantic Beach, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area a.Frame-Wood,Exterior R=19.0 3543.70 ft' 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 301.67 ft' 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 2114.00 ft' 6. Conditioned floor area(ft') . 3529 b.Under Attic(Vented) R=19.0 309.00 ft' c.N/A R= ft2 7. Windows'" Description Area R ft2 11.Ducts a. U-Factor: Dbl,U=0.34 470.56 ft' a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 415 - • • SHGC: , SHGC=0.27 b.Sup: Attic,Ret:Attic,AH:2nd Floor 6 209 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 42.0 SEER:14.00 SHGC: b.Central Unit 18.0 SEER:14.00 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 42.0 HSPF:8.20 Area Weighted Average Overhang Depth: 3.691 ft. b.Electric Heat Pump 18.0 HSPF:8.20 • Area Weighted Average SHGC: 0.270 ' 8. Floor Types Insulation Area 14.Hot water systems Cap: 1 gallons a.Slab-On-Grade Edge Insulation R=0.0 2305.00 ft' a.Natural Gas EF:0.8 b.Floor Over Other Space R=0.0 1106.00 ft2 • b. Conservation features • c.other(see details) R= 118.00 ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building ` ' TkIE Sr ,,y 4 Air '.,.* Construction through the above energy saving features which will be installed (or exceeded) s tip �," `--. 4'o`, in this home before final inspection. Otherwise, a new.EPL Display Card will be completed -"co .;;,;"A` 4,"_,�'s..'{✓.�`� based on installed Code compliant features. �` " Date: G • Builder Signature: fr .L,/ � �✓Y '411/((1" / 1... Address of New Home: tA4; •i ,I.,-/ f t}( y,��``,' City/FL Zip: 1,•c.- rt�i� h c:_ I5 -'2 ``f�' ._,„...-•' S ,,, • *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. • **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/5/2018 4:14 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 I I Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: Lot 150 Atlantic Beach CC Permit Number: Atlantic Beach,FL, • MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL • R401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) • display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402:4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to . comply with Section C402.5. • R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing • methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installatlon.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be Installed in accordance with the manufacturer's instructions and the criteria listed In Table R402.4.1.1,as applicable to the method of construction.Where required • by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. •. • During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond • intended infiltration control measures. 3. Interior doors,if installed at the time of the test,shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems,if installed at the time of the test,shall be turned off. • 6. Supply and return registers,if installed at the time of the test,shall be fully open. - R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors, and outdoor combustion air.Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air leakage Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 L/s/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 7/5/2018 4:14 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Compile Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be fully gasketed and any water lines and ducts In the room insulated in accordance with Section R403.The combustion air duct shall be Insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. • R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not • more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. R403.1.1 Thermostat provision(Mandatory). At least one..thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section • C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or (7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing(Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manufacturer's air handler enclosure If installed at the time of the test.All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test. Exceptions: . ._ . 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping Insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. • R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 7/5/2018 4:14 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017)Complian Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 Y2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. • R403.5.6 Water heater efficiencies(Mandatory). • • R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable • of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of . combustion types of service water-heating systems to be turned off. R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of ' Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems should meet the following criteria: - 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be.installed at an orientation.within 45 degrees of true south. R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential,or Florida Building.Code,Mechanical,as applicable,or with other approved means of ventilation • including:Natural,Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole-house mechanical ventilation system fan efficacy. When Installed to function as a whole-house mechanical • ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. When Installed to function as a.whole-house mechanical ' ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum•rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. • 3• If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10 otherwise. R403.7 Heating and cooling equipment(Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOWC RATE MAXIMUN (CFM) (CFM/WATT) M) Range hoods Any. .2.8 cfm/watt Any In-line fan Any 2.8 cfm/wattAny Bathroom,utility room 10 1.4 cfm/watt <90 Bathroom,utility room 90 2.8 cfm/watt Any For SI:1 cfm=28.3 L./min. a. When tested in accordance with HVI Standard 916 7/5/2018 4:14 PM EnergyGauge0 USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) only equipment R403.7.1.1 Cooling equipment capacity. Coolinga ui ment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's , expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. • Design values for entering wet-bulb and dry-bulb temperatures shall be.for the indoor dry bulb and relative humidity used for the load • calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity Is less than the calculated total sensible load but not less than 80 percent of that load. . 2. . When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section . . • R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within'4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variablecapacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections • C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. • R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no precipitation is fallingand an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8°C). . R403.10 Pools and permanent spa energy consumption(Mandatory).. .. The energy consumption of pools and permanent spas - . • shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessibleon-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: . 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered.exclusively from on-site renewable generation. • R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal. • _ efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 7/512018 4:14 PM 9Y 9 Ener Gau e®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas(MandatorSl)he energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 . • ELECTRICAL POWER AND LIGHTING SYSTEMS • R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installedlighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. • Exception:Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory).Fuel gas lighting systems shall not have continuously burning pilot lights. • I � • • 7/5/2016 4:14 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Compile Page 5 of 5 2017-AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA �I TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA • Project Name: San Tropez 3530 Right NE Builder Name: Toll Brothers Street: Lot 150 Atlantic Beach CC Permit Office: Duval City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Toll Brothers Jurisdiction: 261300 Design Location: FL,Jacksonville • COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA • General A continuous air barrier shall be installed in•the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. • .. . The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. • Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. • The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls Walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch • Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Riin joists shall include the air barrier. Rim joists shall be insulated. • • Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to . (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where proyidedinstead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. . Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to . exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on Narrow cavities installation readily conforms to the available cavity spaces. . Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Batt insulation shall be cut neatly to fit around wiring Plumbing and wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind pining and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover dates and walls or cellinas a. In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. I 7/5/2018 4:15 PM EnergyGauge®USA-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 1 Ii FORM R405-2017 Envelope Leakage Test Report Performance FLORIDA ENERGY EFFICIENCY CODE 111` FOR BUILDING CONSTRUCTION • Envelope Leakage Test Report Performance Method Project Name: San Tropez 3530 Right NE Builder Name: Toll Brothers • Street: Lot 150 Atlantic Beach CC Permit Office: Duval City,State,Zip: Atlantic Beach, FL, Permit Number: Design Location: FL,Jacksonville Jurisdiction: 261300 . • Cond.Floor Area:: 3529 sq.ft. Cond.Volume: 34066 cu ft. . Envelope Leakage Test Results Leakage Characteristics Regression Data: . C: n: R: • Single or Multi Point Test Data Required ACH(50)from • . HOUSE PRESSURE . FLOW: FORM R405-2017 : • 1 Pa cfm . 2 . Pa cfm Tested ACH(50)*: 3 Pa cfm *Tested leakage must be less than or equal to the 4 Pa cfm required ACH(50)shown on Form R405-2017 for , this building. If the tested ACH(50)is less than 3 5 Pa cfm the building must have a mechanical ventilation 6 Pa cfm system. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour _ in Climate Zones 1 and 2...Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: . - ._. ... . 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3. Interior doors,if installed at the time of the test,shall be open; • 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; . 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Testing shall be conducted by either ,,�`O� E.STA:F"' performance results demonstrate compliance individuals as defined in Section .,,'�y;:,� i.Z%�= 0,�, w 553.993(5)or(7), Florida Statutes or • meq..,fi,y..-Q.'r;+=;,-,,`"' t � with Florida Energy Code requirements in 1 til r/74 ''' `' oss o ? accordance with Section R402.4.1.2. • individuals licensed as set forth in ,,;,, ��,, Section 489.105(3)(f),(g),or(i)or an w �r' �J ."`d. approved third party.A written report of =. 1 h 1 a ' the results of the test shall be signed t * a * a SIGNATURE: by the third party conducting the test % {,� 4Y //.,S.' and provided to the code official. '4,,C©�.1NE' ,+° PRINTED NAME: BUILDING OFFICIAL: DATE: DATE: 7/5/2018 4:15 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 Project Summary Dae: Lot 150 ABCC • (CiG�6r,� ,' (Rest of House) By: Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax 904-278-0366 Email.saldie@mcgowansac.com Web:www.mcgowansac.com License:CMC1... Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, FL 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Notes: San Tropez Desi•n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 24 °F Daily range M Relative humidity 50 Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 28193 Btuh Structure 23611 Btuh Ducts 3375 Btuh Ducts 4185 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 31569 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 27796 Btuh Method Blower door Latent Cooling Equipment Load Sizing Shielding/stories 3(partial)/2 Pressure/AVF 50 Pa/3842 cfm Structure 6369 Btuh Ducts 743 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 2305 2305 Equipment latent load 7112 Btuh Volume(ft3) 21875 21875 Air changes/hour 0.61 0.38 Equipment Total Load(Sen+Lat) 34909 Btuh Equiv.AVF(cfm) 223 140 Req.total capacity at 0.70 SHR 3.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB0420000A0 Cond CH14NB0420000A0 AHRI ref 9162578 Coil FB4CNP042L AHRI ref 9162578 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 28000 Btuh Heating output 41000 Btuh @ 47°F Latent cooling 12000 Btuh Temperature rise 30 °F Total cooling 40000 Btuh Actual air flow 1225 cfm Actual air flow 1225 cfm Air flow factor 0.039 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.80 Capacity balance point=26°F Backup: Input=9 kW, Output=31569 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrdghtsoft" 2018-Jul-05 15:51:29 w --- —•—• Comfort Builder by Wrightsoft 18.0.19 RSU03444 Page 1 AC ...top\San Tropez 3530 Right NE-Lot 150 ABCC.rup Calc=MJ8 Front Door faces:NE nil, V Project Summary Job: Lot 150 ABCC 2nd Fl Date: ifffie'!ortad By: Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie@mcgowansaccorn Web:www.mcgowansac.com License:CMC1... Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, FL 32081 Phone: (904) 217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Notes: San Tropez Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 24 °F Daily range M Relative humidity 50 % Moisture difference 61 grill) Heating Summary Sensible Cooling Equipment Load Sizing Structure 11668 Btuh Structure 9280 Btuh Ducts 1575 Btuh Ducts 2000 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 13243 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 12750 Btuh Method Blower door Latent Cooling Equipment Load Sizing Shielding/stories 3(partial)/2 Pressure/AVF 50 Pa/3842 cfm Structure 4421 Btuh Ducts 385 Btuh Central vent(0 cfm) 0 Btuh Area(ft2) Heating - Cooling (none) 4 Equipment latent load 2894 Btuh Volume(ft3) 11054 11054 Air changes/hour 0.80 0.50 Equipment Total Load (Sen+Lat) 15644 Btuh Equiv.AVF (cfm) 148 93 Req.total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model CH14NB0180000A0 Cond CH14NB0180000A0 AHRI ref 9162108 Coil FB4CNP018L AHRI ref 9162108 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 12460 Btuh Heating output 17600 Btuh @ 47°F Latent cooling 5340 Btuh Temperature rise 27 °F Total cooling 17800 Btuh Actual air flow 593 cfm Actual air flow 593 cfm Air flow factor 0.045 cfm/Btuh Air flow factor 0.053 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.70 Capacity balance point=26°F Backup: Input=4 kW, Output= 13243 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -M$- wrigt itstoft- 2018-Jul-05 15:51:29 - .,.,- - • Comfort Builder by Wrightsoft 18.0.19 RSU03444 Page 2 ACCA ..top\San Tropez 3530 Right NE-Lot 150 ABCC.rup Calc=MJ8 Front Door faces:NE A = N First Floor 14x1414x14 12" BREAKFAS. 10 x 6; 6x10 6" 12x6 = 6" m.wic2 lo; MASTER SUITE 10x6 8x4 6' ; 4' 0° SAN I ., o0 . FAMILY ROOK 6x10 8 x a 6 4 KITCHEN N 10 x 10 Mwic ■ m. batt ,. 6" 8 — — 12„ 12x6 9 10x10 , NW 7„ P.M lwle 18x24 4x8 8x4 Indry q.., q " Fan - WC ' "' 10x6 O D aJ 5" oantrl \3" Fan 8x4 . OA 4" a 3"Fan 8x4 THUR 4" bath ROOF r.11 ... 12x6 14x67" 8„ S/W GARAGE FOYER/STAIR: Dining y ----'. — o 1 I I Job #: Lot 150 ABCCMcGowan's Heating & Air Conditionin Scale: 1 : 92 Performed by Saldie Guintivano for: Page 1 Steve Marten 11320 E.Phillips Parkway Dr. Comfort Builder by Wrightsoft 160 Cape May Ave. Jacksonville,FL 32256 18.0.19 RSU03444 Ponta Vedra,FL 32081 Phone:904-278-0339 Fax:904-278-0366 2018-Jul-05 15:52:28 Phone:(904)217-0217-0739 Fax:(904)814-8173 www.tollbrothers.com smarten@tollbrotherslnc corn www.mcgowansac.com saldie©mcgowansac.com ...3530 Right NE-Lot 150 ABCC.ii i►_ N 2ND FL , o t t 3"Fan I\ 'bath 2 111 P.J 8x4 " 4' bed 3 bed 2 12x6 4x8 12x6 kl . 4 �" ■■i 12 x 12 ■• rj 12 9 12 sinks J 14'' ---------- . "44 410 10x6 :u r.. 10x6 16 ' 6" 12„ 6 4x8 . 4" s A/C to e illtilli12" 14.. LOFT • 16 18x18 WIC4 ... 14" ', v 4x8 attic 4„ O /l EA ... 3" Fan 2x12 12x6 BATH3 7„ Ret 'iser i.: g ' 16„ 10x6 6" BEDROOM z OPEN TO BELOV , I Job #: Lot 150 ABCCMcGowan's Heating & Air Conditionir Scale: 1 : 92 Performed by Saldie Guintivano for: Paget Steve Merten 11320 E.Phillips Parkway Dr. Comfort Builder by Wrightsoft 160 Cape May Ave. Jacksonville,FL 32256 18.0.19 RSU03444 Ponte Vedra,FL 32081 Phone:904-278-0339 Fax:904-278-0366 2018-Jul-05 15:52:28 Phone:(904)217-0739 Fax:(904)814-8173 www.tollbrothers.corn smerten@tollbrothersinc.com www.mcgowansac.com saldie@mcgowansac.com ...3530 Right NE-Lot 150 ABCC.rt Manual S Compliance Report Job: Lot 150 ABCC Date: ,ffc 4 (Rest of House) By: Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone.904-278-0339 Fax 904-278-0366 Email.saldie@mcgowansac corn Web:www.mcgowansac.com License:CMC1... Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, FL 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 27796 Btuh Entering coil DB: 75.7°F Outdoor design WB: 80.2°F Latent gain: 7112 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 34909 Btuh Indoor RH: 50% Estimated airflow: 1225 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH 14NB0420000A0+FB4CNP042L Actual airflow: 1225 cfm Sensible capacity: 28568 Btuh 103%of load Latent capacity: 7697 Btuh 108%of load Total capacity: 36265 Btuh 104%of load SHR: 79% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 31569 Btuh Entering coil DB: 69.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH 14NB0420000A0+FB4CNP042L Actual airflow: 1225 cfm Output capacity: 32361 Btuh 103%of load Capacity balance: 26 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1225 cfm Output capacity: 9.3 kW 100%of load Temp. rise: 25 °F Meets all requirements of ACCA Manual S. W r ilgJf t1tS0f!t' 2018-Jul-05 15:51:29 Comfort Builder by Wnghlsoft 18.0.19 RSU03444 PageALAA ..top\San Tropez 3530 Right NE-Lot 150 ABCC.rup Calc=MJ8 Front Door faces:NE ., Manual S Compliance Report Job: Lot 150 ABCC Date: i�'� oHt� r� e� 2nd Fl By: Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie@mcgowansac corn Web:www.mcgowansac.com License:CMC1... Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, FL 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 12750 Btuh Entering coil DB: 75.9°F Outdoor design WB: 80.2°F Latent gain: 2894 Btuh Entering coil WB: 63.0°F Indoor design DB: 75.0°F Total gain: 15644 Btuh Indoor RH: 50% Estimated airflow: 593 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0180000A0+FB4CNP018L Actual airflow: 593 cfm Sensible capacity: 13107 Btuh 103%of load Latent capacity: 3057 Btuh 106%of load Total capacity: 16164 Btuh 103%of load SHR: 81% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 13243 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH 14NB0180000A0+FB4CNP018L Actual airflow: 593 cfm Output capacity: 17600 Btuh 133%of load Capacity balance: 26 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 593 cfm Output capacity: 3.9 kW 100%of load Temp. rise: 55 °F Meets all requirements of ACCA Manual S. A' wrighttsoft` 2018-Jul-0515:51:29 Comfort Builder by Wrightsoft 18.0.19 RSU03444 Page 2 AC ...top\San Tropez 3530 Right NE-Lot 150 ABCC.rup Calc=MJ8 Front Door faces:NE Duct System Summary Dat Lot 150 ABCC rd (Rest of House) B Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie@mcgowansac.com Web:www.mcgowansac.com License:CMC1... Project Information For: Steve Meilen,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, FL 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.228/0.162 in H2O 0.228/0.162 in H2O Lowest friction rate 0.080 in/100ft 0.080 in/100ft Actual air flow 1225 cfm 1225 cfm Total effective length (TEL) 485 ft Supply Branch Detail Table Design Htg Clg Design ' Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln (ft) Trunk BREAKFAST h 3723 144 126 0.115 7.0 Ox 0 VIFx 53.5 145.0 st2 Dining h 8875 344 287 0.091 8.0 Ox 0 VIFx 60.5 190.0 st6 FAMILY ROOM-A c 2480 74 109 0.122 6.0 Ox 0 VIFx 41.6 145.0 st2 FAMILY ROOM-B C 2480 74 109 0.115 6.0 Ox 0 VIFx 52.4 145.0 st2 FAMILY ROOM-C c 2480 74 109 0.080 7.0 Ox 0 VIFx 78.5 205.0 st5 KITCHEN C 2690 118 119 0.097 7.0 Ox 0 VIFx 49.5 185.0 st6 MASTER SUITE-A c 1632 55 72 0.110 6.0 Ox 0 VIFx 36.8 170.0 st7 MASTER SUITE-B C 1632 55 72 0.119 6.0 Ox 0 VIFx 30.8 160.0 st7 Mwic c 1 0 0 0.114 4.0 Ox 0 VIFx 34.8 165.0 st7 bath h 1720 67 47 0.088 4.0 Ox 0 VIFx 60.3 200.0 st5 Indry C 698 10 31 0.112 4.0 Ox 0 VIFx 32.6 170.0 st7 m.bath h 2712 105 80 0.118 5.0 Ox 0 VIFx 28.0 165.0 st7 m.wic 2 h 2524 98 42 0.116 4.0 Ox 0 VIFx 31.3 165.0 st7 pantry C 394 2 17 0.093 4.0 Ox 0 VIFx 54.2 190.0 st6 we h 149 6 4 0.118 4.0 Ox 0 VIFx 29.0 165.0 st7 Supply Trunk Detail Table Trunk Htg CIg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st5 Peak AVF 141 156 0.080 447 8.0 0 x 0 VinIFIx st2 st2 Peak AVF 896 924 0.080 864 14.0 0 x 0 VinlFlx st6 Peak AVF 464 423 0.091 1050 9.0 0 x 0 VinlFlx st2 st7 Peak AVF 329 301 0.110 418 12.0 0 x 0 VinlFlx st3 st3 Peak AVF 329 301 0.110 418 12.0 0 x 0 VinIFIx - wrightsoft- 2018-Jul-0515:51:29 ----, - Comfort Builder by Wrightson 18.0.19 RSU03444 Page 1 ..top\San Tropez 3530 Right NE-Lot 150 ABCC.rup Calc=MJ8 Front Door faces:NE Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb8 Ox 0 1225 1225 201.6 0.080 877 16.0 Ox 0 VIFx -Pie- wrightsoft- 2018-Jul-0515:51:29 ..z. Comfort Builder by Wrightsoft 18.0.19 RSU03444 .�_,. ,_......�............. Page 2 / ...top\San Tropez 3530 Right NE-Lot 150 ABCC.rup Calc=MJ8 Front Door faces:NE Duct System Summary Date: Lot 150 ABCC ific i 4J 2nd FI By: Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie©mcgowansac.com Web:www.mcgowansac.com License:CMC1... Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, FL 32081 Phone: (904) 217-0739 Fax: (904) 814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.235/0.155 in H2O 0.235/0.155 in H2O Lowest friction rate 0.105 in/100ft 0.105 in/100ft Actual air flow 593 cfm 593 cfm Total effective length (TEL) 371 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln (ft) Trunk A/C h 1107 50 35 0.158 4.0 Ox 0 VIFx 8.5 140.0 st1 BATH 3 h 1228 55 38 0.146 4.0 Ox 0 VIFx 16.5 145.0 st1 BEDROOM 4 c 1999 104 105 0.143 7.0 Ox 0 VIFx 19.5 145.0 st1 LOFT h 656 29 25 0.148 6.0 Ox 0 VIFx 13.6 145.0 st1 LOFT-A h 656 29 25 0.108 6.0 Ox 0 VIFx 28.7 190.0 st4 LOFT-B h 656 29 25 0.107 6.0 Ox 0 VIFx 34.0 185.0 st4 wIC 4 c 70 3 4 0.149 4.0 Ox 0 VIFx 13.1 145.0 st1 bath 2 h 555 25 22 0.105 4.0 Ox 0 VIFx 38.5 185.0 st4 bed 2 c 2537 121 133 0.109 7.0 Ox 0 VIFx 30.4 185.0 st4 bed 3 c 3338 145 176 0.145 7.0 Ox 0 VIFx 16.9 145.0 st1 sinks c 101 3 5 0.108 4.0 Ox 0 VIFx 32.3 185.0 st4 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 208 211 0.105 269 12.0 0 x 0 VinIFIx st1 st1 Peak AVF 593 593 0.105 555 14.0 0 x 0 VinIFIx wriightsoft- 2018-Jul-05 15:51:29 .a`.. .•.... .�. Comfort Builder by Wrightsoft 18.0.19 RSU03444 Page 3 ACC ...top\San Tropez 3530 Right NE-Lot 150 ABCC.rup Calc=MJ8 Front Door faces:NE Return Branch Detail Table Grille Htg CIg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb11 Ox 0 82 64 135.9 0.114 77 14.0 Ox 0 VIFx ill rb14 Ox 0 175 181 147.3 0.105 409 9.0 Ox 0 VIFx ill rb13 Ox 0 178 206 143.7 0.108 467 9.0 Ox 0 VIFx rtl rb12 Ox 0 159 143 139.6 0.111 359 9.0 Ox 0 VIFx ill Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rtl Peak AVF 593 593 0.105 425 16.0 0 x 0 VinIFIx lwrI htscaft` 2018-Jul-OS 15:51:29 --.--, .... - Comfort Builder by Wrightsoft 18.0.19 RSU03444 Page 4 AC ...top\San Tropez 3530 Right NE-Lot 150 ABCC.rup Calc=MJ8 Front Door faces:NE