Loading...
1727 ATLANTIC BEACH DR - NEW SINGLE FAMILY PERMIT r.-L`lr� ,„,s, CITY OF ATLANTIC BEACH m r.' 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 �r�,t»f' INSPECTION PHONE LINE 247-5814 RESIDENTIAL - NEW SINGLE FAMILY RESIDENCE MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES18-0247 Description: Estimated Value: 487503.1 Issue Date: 8/8/2018 Expiration Date: 2/4/2019 PROPERTY ADDRESS: Address: 1727 ATLANTIC BEACH DR RE Number: 169505 1440 PROPERTY OWNER: Name: ATLANTIC BEACH PARTNERS LLC Address: 414 OLD HARTS RD STE 502 FLEMING ISLAND, FL 32003 GENERAL CONTRACTOR INFORMATION: Name: Address: , Phone: Name: TOLL FL VI LIMITED PARTNERSHIP Address: 250 GIBRALTAR RD HORSHAM, PA 19044 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. • ` City of Atlantic Beach r,' Il • PUBLIC UTILITIES DEPARTMENT ~� �,� 1200 Sandpiper Lane ,%I. Atlantic Beach, FL 32233 (904)247-5834 I IEW WATER/ SEWER TAP REQUEST Date 7-/9 / 8 Project Address /70 7 /T/,q /( Oe/-1 (Dr- Number of Units / Commercial Residential 7 Multi-Family If New Water Tap(s) & Meter(s) Meter Size(s) e/ New Irrigation Meter V Upgrade Existing Meter from to (size) New Reclaim Water Meter V Size `3/y New Connection to City Sewer Applicant Name Applicant Address City State Zip Phone Cell Email Applicant Signature �� CITY STAFF USE ONLY Application# ICE 5 I R — 0 '2 t/7 Water System Development Charge $ I , H-10, 00 C C Sewer System Development Charge $y, O 5O 1 00 Water Meter Only $ I SS. DC7 Reclaim Meter Only $ / IRS", 00 Water Meter Tap $ Sewer Tap $ Cross Connection $ 50' OD Other $ TOTAL $ 5 6 /0 , 0/-� (Notes) APPROVED Kayle Moore, P.E. �(A', Date IN 6r Public Utilities Director or Authorized Signature ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED fir! ic . City of Atlantic Beach APPLICATION NUMBER N�: > �S Building Department (To be assigned by the Building Department.) 1±,it,:, 800 Seminole Road, kE5r —O2 h �[ �� sz•I Atlantic Beach, Florda 32233-5445 ` O2- -f 7 \ Phone(904)247-5826 • Fax(904) 247-5845 a 401119:- E-mail: building-dept@coab.us Date routed: 1P.M 0 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: «2l fv1/4- L Beall Department review required Yes No uildi Applicant: \ btk 4S`(.0 S - g- Tree Administrator Project: J\h3e.._ �C�.lv‘.i t\ -ublic Wor'' Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: <Droved. Denied. ❑Not applicable (Circle one.) Comments: fIO BUILDING PLANNING &ZONING /2' P '/ . / k" Reviewed by: / 1 Date: TREE ADMIN. Second Review: I lApproved as revised. ❑Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. Denied. Not applicable Comments: Reviewed by: Date: Revised 0 5/1 912 01 7 urriut uurY 71 Building Permit Application Updated 12/8/17 - City of Atlantic Beach ,,, „� 800 Seminole Road,Atlantic Beach,FL 32233 Phone:(904)247-5826 Fax:(904)247-5845 £ES��' (:).2.,4-1Job Address: 1727 Atlantic Beach Drive Permit Number: Legal Description Lot 29 Atlantic Beach Country Club Unit 2, Parcel #67-52 16-25-29E RE# 169505-1440 Valuation of Work(Replacement Cost)$441349 Heated/Cooled SF 3854 Non-Heated/Cooled 1067 • Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): Commercial Residential • If an existing structure, is a fire sprinkler system installed?(Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: New home construction Florida Product Approval#see attar.hed for multiple products use product approval form Property Owner Information Name: Toll FL VI I Limited Partnership Address: 160 Cape May Avenue City Ponte Vedra State FL Zip 32081 Phone 904-217-0739 E-Mail aregnier@tollbrothers.com Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Toll FL VI, LP Contractor Information Name of Company: Toll Bros., Inc Qualifying Agent: Steven R. Herten Address 160 Cape May Avenue City Ponte Vedra State FL Zip 32081 Office Phone 904-595-5243 Job Site/Contact Number 904-595-5243 State Certification/Registration# CGC1510225 E-Mail aregnier@tollbrothers.com Architect Name& Phone# Toll Architecture(407)248-5800 Engineer's Name&Phone# Lou Pontigo&Associates(904)242-0908 Workers Compensation Policy#MWC30267702/Expries 9/1/2018 Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, 1.NSULT WITH YOUR LENDER OR AN ATTORNE :EFORE RECORDING YOUR N• E OF COMMENCEMENT. • ..�uontractor (Signa re o • ner or Agent) ( ) ncluding contractor) Signed and sworn to(or affirmed) before me this 1S day of Signed and sworn to(or affirmed) before me this i5 day of 1W"\k... , 0201 , by ' Ale Mei (i"iti JUjd\L , SIX, by ' ' " ft ( l (Si nature of Notary) 40 ( ture of Notary) [ Personally Known OR �4}Rr % Notary Public State of Florida [ ersonally Known OR Cyt Notary public State of Florida Melissa Sue Lieberman Produced Identification .>p Melissa Sue Lieberman [ ]Produced Identificatio [ ] ,_ My Commission GG 128088 . M Commission GG 128068 Type of Identification: ;; ', Erpi,es 00/1R/9n21 Type of Identification: •. y , or t�' OFFICE COP\ PERMITTED BUILDING DATA DO NOT WRITE BELOW — OFFICE USE ONLY Applicable Codes: 6th Edition (2017) Florida Building Code DEVELOPMENT SIZE: Habitable Space (ft") 3 Non-Habitable Space (ft') IOC LAND INFORMATION: Zoning District R36L Flood Zone X Minimum FFE /0, 8c/ (prop. /2./o' BUILDING INFORMATION: Construction Type 5 Occupancy Group Sinj1.e fia m; /y Number of Stories Max Occupancy Load Fire Sprinklers Required 71/4 CONDITIONS/ COMMENTS: Rev. 2.7.2018 01-i-vv City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole RoadkrE51 C OT 47 '- - -, Atlantic Beach, Florida 32233-5445 MB o "I y) Phone(904)247-5826 • Fax(904)247-5845 JUL , 20113 /1ifI pE-mail: building-dept@coab.us Date routed: 0City web site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: t-121 iskIckmic, Sea( '- Department review required Yes No uildi Applicant: \ bl\ Try S - i Tree Administrator Project: J1,,(�l� g'vu P& t�,• -ublic Wor' r I •u. ie. `l Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: IlApproved. (Denied. Not applicable (Circle one.) Comments: BUILDING % PLANNING &ZONING Reviewed by: Date: I'lyie TREE ADMIN. Second Review: ❑Approved as revised. Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 13� r REVOCABLE ENCROACHMENT AGREEMENT REVOCABLE ENCROACHMENT AGREEMENT by the City of Atlantic Beach,Florida,a municipal corporation organized and existing under the laws of the State of Florida,hereinafter referred to as"CITY"and TOLL FL VI,LP of Atlantic Beach,Florida,hereinafter referred to as"USER". WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property for the purpose as described in the City of Atlantic Beach. This work is generally described as Pavers in the Right-of-Way for the driveway. Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty(30) days' notice by CITY to USER, said notice to USER shall be given by certified mail, return receipt requested,to the following address 1727 Atlantic Beach Dr' Parcel#67-132 08-2S-29E . • In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above described easement or property of the CITY,the USER shall replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining,repairing,operating,replacing or adding to of the utilities and facilities of the CITY or franchise utility provider. • The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes, Land Development Code and all other land use and code requirements of the CITY,including City Code Section 19-7(h) which states "Driveways that cross sidewalks: City sidewalks may not be replaced with other materials, but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." • The USER,prior to making any changes from the approved plans and/or method,must obtain written approval from the City of Atlantic Beach Public Works Department,for said change within 30 days after the day of completion. • This permit shall inure to the benefit of,and be binding upon,the USER and their respective successors and assigns. • USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications,to include utilities locate requirements and use limitations/requirements of easements, public right- of-ways and other public land. USER further agrees that the CITY and its officers and employees shall be saved harmless by the USER • .m any of the work herein under the terms of this permit and that all of said liabilities are hereby assumed by SER. / f� Date L �v Property Owner/Agent41) in presence of Notary Public) STATE OF FLORIDA,COUNTY OF JD!+'-5 The foregoing instrument was acknowledged this /5- day of JIAJU- ,201 d , by 3 T t M`DL.Z1✓ ,who personally appeared before me and (printed name of Signer) acknowledged that he/she ' ed the instrument voluntarily for the purpose expressed in it. Signatur of tary Public, State of Florida _ Department Approval: Personally Known\i- • Produced Identification(Type) Sco 1 ams,Pu lic Works Director/ 00 ouc Notary Public State of Florida Kayle Moore,Public Utilities Director H:\Master Forms\Public- ieilit aks hielivickSt tai /8(Thment :reement 2.5.18.docx Revision Date:2/5/18 .. ` My Commission GG 126068 "10.1, Expires 09/18/2021 0 RIGHT-OF-WAY/ EASEMENT PERMIT Permit#Issued by the City of Atlantic Beach PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES Job Address 1727Atlantic Beach Drive Phone 904-595-5243 Permittee Steven Merten Email aregnierAtollbrothers.com Requesting Permission to Construct Pavers in the Right of Way for the driveway Location (Reference to Cross-Street) Coastal Oak Lane&Atlantic Beach Dr. -06884 ATLANTIC BEACH COUNTRY CLUB UNIT 02 • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement,maintenance, safe and efficient operation, alteration or relocation of all,or any portion of said street or easement as determined by the Director of Public Works,any or all said poles,wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of _ Matt Olive (Project Superintendent) located at 237 9th Avenue North,Suite 4,Jacksonville Beach,FL 32250 . • All materials and equipment shall be subject to inspection by the Director of Public Works. • All city property shall be restored to its original condition as far as practical, in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • The permittee shall commence actual construction in good faith within days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,title and interest in the land to be entered upon and used by the holder,and the holder will,at all times, assume all risk of and indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. • The Director of Pub '1 orks shall be notified twenty-four(24)hours prior to starting work and again immediately upo • pletion. Date & ASAAl Permittee: Steven R. e ra ivision President,TOLLFL VI,LP(signed in presence of Notary Public) STATE OF FLO' IDA,COUNTY OF SAINT JOHNS „.....-- J The foregoing instrumentTE was acknowledged this /5 day of li / ,20 , by V J/fT--A✓ ,who personally appeared before me and (printed name of Permittee) acknowledged that h• '..•. the instrument voluntarily for the purpose expressed in it. lipot —1) itk Personally Known Signature of Notary 'u• to ;o • '. 'roduced Identification(Type) et' Notary Public State of Florida t.4Melissa Sue Lieberman fMy Commission GG 128088 '?a-f' Expires 09/18/2021 01-A4rr, City of Atlantic Beach APPLICATION NUMBER ys4o Building Department (To be assigned by the Building Department.) 800 Seminole Road C�b2 �" Atlantic Beach, Florida 32233-5445 a 2013 o Phone(904)247-5826 • Fax(904)247-5845 t� / Q E-mail: building-dept@coab.us Date routed: —1 VIP 6 City web-site: http://www.coab.us i ! APPLICATION REVIEW AND TRACKING FORM Property Address: 0121 beat,- Department review required Yes No uildi Applicant: \ bt\ <n O S . c Tree Administrator Project: J` l� Pctiv\,1 k` ublic Wor lie 9 Public Safety Fire Services Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: 17fApproved. ['Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: ig1 h/ — Date: yt r TREE ADMIN. Second Review: A roved as revised. ❑ pp ❑Denied. Not applicable PU WORKS Comments: "I BLIC U L ES PUBLIC SAFETY `" Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. nDenied. [Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 �S!.�L��r� City of Atlantic Beach APPLICATION NUMBER (� .Y.� Building Department (To be assigned by the Building Department.) '1 12E51 47 800 Seminole Road j,., �r Atlantic Beach, Florida 32233-5445 � �,; Phone(904)247-5826 • Fax(904)247-5845 Q�J;3 �' E-mail: building-dept@coab.us Date routed: 1 PI/ OCity web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: V12-1 fvf-lc mic, Seojj.i Department review required Yes No uildillp Applicant: ` b \ XD S . I jpg$7nnin7 Tree Administrator Project: J‘1\,5e._ PQ.m.1 I ublic Wor ublic Utilitie. Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. ['Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by:/°1 Date: - i q. l e TREE ADMIN. Second Review: ['Approved as revised. Denied. ['Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ['Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 MAP SHOWING PLOT PLAN OF LOT 29 AS SHOWN ON MAP OF ATLANTIC BEACH COUNTRY CLUB UNIT 2 AS RECORDED IN PLAT BOOK 67 PAGES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUAL COUNTY, FIA. CERTIFIED TO: TOLL BROTHERS, INC. S) BUILDERS ENDORSEMENT SIGNED: NAME: DATE: ALL PAVERS ALL MEASUREMENTS ESTIMATED FRONT 516* SQ. FT. BACK 259± SQ. FT. 0 / ``<3 "5 >; 002\02•\ '% o 8 ���/ o\.. V. .1 1� •.•o to40- •41 \ \ Pin O. � ` P • \\ 49 \ yr • QRog'W 00"..4P \) r4p` �`h. •0F.�'',kh�0 1 �Ol 'u` ff3`.J"pt •�°\. y�11. Q co O, • tt �pP4 %%%%%%%%�q \\%U SI' Q X41\\4 f� \\\.\\\ \\\ ..•0 �,c�0� $� COMMUNITY DEVELOPMENT OJ�Qy�P • � ° APPROVED \. ,peon 9. , � 4' P. --^-DENOTES DIRECTION OF FLOW TYPE 'A' DRAINAGE ELEVATIONS SHOWN THUS (10.80) WERE TAKEN FROM ENGINEERING PLANS BY TAYLOR h WHITE, INC., DATED 04-15-14 DIMENSIONS SHOWN HEREON ARE PER FOUNDATION PLAN ELEVATIONS SHOWN HEREON REFER TO NAVD OF 1988 LOT 29 MODEL"CAPTIVA" LOT SIZE 7,200* SQ. FT. DRIVEWAY TO R/W 320* SO. FT. TREE SCHEDULE NOTE ALL UTILITIES SHOWN ENTRY WALK 37* SQ. FT. HEREON WERE FROM LOT SQ. FT. MINUS EASEMENTS/WETLANDS 6,737 APPROXIMATE SIDEWALK 0± S0. FT. AS-BUILT DRAWINGS ACRES=6,737/43,560 0.16 PROVIDED BY CODYS ACRESx40••REQUIRED TREE INCHES 6.4 RIGHT-OF-WAY LENGTH 60.00 FT. PROFESSIONAL SURVEYING TOTAL IMPERVIOUS COVERAGE 4,255* SQ. FT. 59% AND MAPPING, INC. THE REQUIRED NUMBER OF TREE INCHES WILL BE MET TOTAL EASEMENT AREA 463± SD. FT. 12-18-14; JOB #10114 USING 2R DIAMETER TREES. 70X OF REQUIRED PLANTED TREES SHALL BE CANOPY TYPE, WITH NO MORE THAN 50%OF THE SAME SPECIES. THE LOT SHOWN HEREON IS IN THE SPECIAL FLOOD HAZARD ZONE "X"AS SHOWN ON LOMR-F CASE NO. 15-04-4216A.DATED MAY 4, 2015 AS SHOWN ON FLOOD INSURANCE RATE MAP 0408 II FOR THE CITY OF JACKSONVILLE,FLORIDA, DATED 08-03-13 ALL AMERICAN SURVEYORS OF FLORIDA, INC. LAND SURVEYORS-3751 SIN JOSE PLACE SUR:15-J4CKSOMULLE FLORIDA, 32257-904/279-0088-LICENSED LAND BUSINESS NO. 3857 L geed 5 RP.E MENIIOOR ELLW F . CM MO. PPOLRO o ,yc , CONDITIONERSKETCH FOR PLOT PLAN ONLY— DOES NOT REPRESENT OR PURPORT TO SHOW cslrr EASEMENT R.D. ORIIVMROM BOUNDARY ONES NOR IS IT BASED ON A FIELD RUN SURVEY —41 COM CONCRETE JG ,MCKSOR8LE ELECTRIC - MON. MONIYDIT NIIICNY LP. IRON PPE P.T. WWII 10/80/01 IT. ROI ROO P.CP. PERIWI911 CDKIROI.POINT ALL a 003.NIDE PIC. "if a OkRRAMERICAN CCHORD A MC mom P.C.C. PDI4T OF COMPOUND CURE SURVEY NOT VAUD UNLESS EMBOSSED BY SEAL SURVEYORS m BWILDINGRESTRCIaN (cuu..) CALCULATED ATED FP4A.L WILDING FLORIDA POWER R LICHT JAMES D.HARRISON A., No. 2647 OF FLORIDA, ((((o3 DEED (TMPD TTPIaL MICHAEL A.GARRETT,No.6643 INC. (N) R DYL LME IMO NATIO GEODETIC.4RIKK SCALE 1' 30 F .EERIER UNE .9 NOON MERMAN HMMAL N, /J F.WIT-OP-W" P.I. POINT CC OITEICECTMII a, 4..,..�,. B -EOMI E. EDGE a MART DATE OS-08-18 M .MINIMI Toe TOP a EIPRR I FLO OISTERED V�VE1'OR MAPPER _8f F.H. X DR. BY 668 DIR. P:\2018\84104-163557-plotp1on ORDER NO. 163557 FILE 84104 MAP SHOWING PLOT PLAN OF LOT 29 AS SHOWN ON MAP OF ATLANTIC BEACH COUNTRY CLUB UNIT 2 AS RECORDED IN PLAT BOOK 67 PAGES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUAL COUNTY, FIA. CERTIFIED TO: TOLL BROTHERS, INC. S5 S GNED:UILDERS ENDORSEMENTSOFFICE ;' >; .' NAME: f� DATE: ALL PAVERS ALL MEASUREMENTS ESTIMATED FRONT 516± SQ. FT. r 1 BACK 259± SQ. FT. 0 Ala //4gC4Z%%:\ r 0 cF%,��a�49 0�� * \ \ s \ ea 3�1 • ;`"�O IIS ,.�jj :t �4. FF 0 u11. 2o • ,C4ti,,i"�f�° ` v ` vie dzi `°,1-Vi ve04t`p2k"te ��44 O V� pro.�0 • 610 \• ti}v\ay.ic Vii0P‘'- it, %.ti's14":�`y s,� 0 ,c \ •%. \ des P f� 95. �O P' y1" f J\ \2P°�,qt, \P4.�1'O ,G. ' --,-DENOTES DIRECTION OF FLOW TYPE -A- DRAINAGE ELEVATIONS SHOWN THUS (10.80) WERE TAKEN FROM ENGINEERING PLANS BY TAYLOR & WHITE, INC., DATED 04-15-14 DIMENSIONS SHOWN HEREON ARE PER FOUNDATION PLAN ELEVATIONS SHOWN HEREON REFER TO NAVD OF 1988 LOT 29 MODEL -CAPTIVA- LOT SIZE 7,200± SO. FT. DRIVEWAY TO R/W 320± SQ. FT. TREE SCHEDULE NOTE ALL OLSHOWN LOT SQ. FT. MINUS EASEMENTS/WETLANDS 6,737 ENTRY WALK 37± SQ. FT. HEREONNWERE FROM APPROXIMATE SIDEWALK 0± SQ. FT. AS-BUILT DRAWINGS ACRES=6,737/43,560 0.16 RIGHT-OF-WAY LENGTH 60.00 FT. PROVIDED BY CODY'S ACRESx40=REQUIRED TREE INCHES 6.4 PROFESSIONAL SURVEYING TOTAL IMPERVIOUS COVERAGE 4,255± SQ. FT. 59% AND MAPPING, INC. THE REQUIRED NUMBER OF TREE INCHES WILL BE MET TOTAL EASEMENT AREA 463± SO. FT. 12-18-14; JOB #10114 USING 2 DIAMETER TREES. 70X OF REQUIRED PLANTED TREES SHALL BE CANOPY TYPE, WITH NO MORE THAN 50%OF THE SAME SPECIES. THE LOT SHOWN HEREON IS IN THE SPECIAL F1.000 HAZARD ZONE"x-AS SHOWN ON LOMB-F CASE NO. 15-04-4216A,DATED MAY 4, 2015 AS SHOWN ON FLOOD INSURANCE RATE MAP 0408 H FOR THE CITY OF JACKSONVILLE,FLORIDA. DATED 06-03-13 ALL AMERICAN SURVEYORS OF FLORIDA, INC. IAMB SURVEMRS-3751 SAI,KOBE PLACE;SUITE 15-,{4CKSONHLLE FLOF8OI.32257-904/279-0068-LENSED LAND BUSINESS MI 3857 L qea 5 �, COVERED PSL-MR ROM MAIM SKETCH FOR PLOT PLAN ONLY- DOES NOT REPRESENT OR PURPORT TO SHOW I.D. -10O BOUNDARY LINES NOR IS IT BASED ON A FIELD RUN SURVEYCOMITIOMM —4I URI coo rt JEA - _ NMCOM CONUM NnNOMT INA* ICN PPE P.T. -POSIT CP TAMMY ALL LP. PW PPE PERMAN R COMM POM Ix. ROM ICO P.C. -PpMf Cf o t,E e 0101 ARM AMERICAN CO CIIOIE PAC.-PONT OP PEWEE OINA! A INC 1508 P.C.C.-PCM Oi COMPOUND COR.O R RIaEa RP.�-RONC 0QM•U SURVEY NOT VALID UNLESS EMBOSSED BY SEAL OF FLORIDA, (C .) Pte)-MRONDAICR. Porn A ugrt JAMES D.HARRISON,JR..No.2647 MICHAEL A.CARREIT,No.6643 INC. v PIAT N,W-WORN.0E00E10 0(x1001 R 0011 IINE Nino -NOA0 A1EA00N VERT./DOUR SCALE 1'-30' wY P.1. -POINT OF MIFf6EC1CN .L..+--��.' 9 -FOOL EOR -ease OP NAM DATE 02-08-18 N) -• TOO -TOP OF OM Pi LOrpo� EJ� RVEYOR LIMPER I 6I P.R. X DR. BY 8R8 DAR. P:\2018\84104-163557-plotplan ORDER NO. 163557 FILE 84104 -- a o I-77o R i 0( FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Captiva 3854 Left SW Builder Name: Toll Brothers,Inc. Street: Lot 29 Atlantic Beach CC Permit Office: Duval City,State,Zip: Atlantic Beach ,FL, Permit Number: Owner: Toll Brothers,Inc. Jurisdiction: 261300 Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(4055.0 sqft.) Insulation Area , 2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=19.0 3836.70 ft2 b.Frame-Wood,Adjacent R=13.0 218.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (3157.0 sqft.) Insulation Area • a.Under Attic(Vented) R=38.0 2840.00 ft2 6. Conditioned floor area above grade(ft2) 3854 b.Under Attic(Vented) R=19.0 317.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 • 11.Ducts R ft2 7. Windows(415.2 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 205 a. U-Factor: Dbl,U=0.34 415.22 ft2 b.Sup: Attic,Ret:Attic,AH:2nd Floor 6 186 SHGC: SHGC=0.27 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 18.0 SEER:14.00 c. U-Factor: N/A ft 2 b.Central Unit 42.0 SEER:14.00 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 18.0 HSPF:8.20 SHGC: b.Electric Heat Pump 42.0 HSPF:8.20 Area Weighted Average Overhang Depth: 6.494 ft. Area Weighted Average SHGC: 0.270 14.Hot water systems 8. Floor Types (3854.0 sqft.) Insulation Area a.Natural Gas Tankless Cap: 1 gallons a.Slab-On-Grade Edge Insulation R=0.0 2882.00 ft2 EF:0.800 b. Conservation features b.Floor Over Other Space R=0.0 697.00 ft2 None c.other(see details) R= 275.00 ft2 15.Credits Pstat Glass/Floor Area: 0.108 Total Proposed Modified Loads: 90.67 _ PASS Total Baseline Loads: 98.2000001N I hereby certify that the plans and specifications covered by Review of the plans and "°1;::: ,v Q4� E ST,q?VIONO try ° 4 this calculation are in compliance with the Florida Energy specifications covered by this ►r'ti. t' " Np. Code. calculation indicates compliance /4,', ,''�;(., '4,.1,•-_-=:._ , ..Vt, '�� it�r. ,_.; �,,�• �`? with the Florida Energy Code. S h 'Jury ...,a e 0 a PREPARED BY: J D�� (�uthj�iu el Before construction is completed t u` - -..-4, DATE: , a- ZD-?,4/ _77._7'0',►" 6-.- 0 0 this building will be inspected fori /a 2 compliance with Section 553.908 * - I hereby certify that this building, as designed, is in compliance Florida Statutes. Ai,....‹ .....c. i with the Florida Enerc�, Code. l ,�tC `.) t gg.,....r ..,..00 OWNER/AGENT' 0)..,,--_-e,12-47I�'}► BUILDING OFFICIAL: /i/y1)..- •• O! DATE: I] (-PI ( f- DATE: Si' /'p'1 dt/r - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 6/20/2018 5:56 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 OFFICE COPY PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA Project Name: Toll Brothers,Inc. Permit# R S/ -0 a f'7 Project Address: 1727 Atlantic Beach Drive Lot 29 As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at:www.floridabuilding.org. Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A. EXTERIOR DOORS 1. Swinging Masonite Wood Edge,Steel N/A Double-FL8228.6 Single-FL6506.4 Simpson Door Company Wood Door FL 14487.1 Therma-Tru Fiberglass/Wood Door N/A FL 5262.3 2. Sliding PGT 2500 Aluminum Slide Glass +25/-25 FL 251 3. Sectional +43.2/-49.6 8 ft FL 9174.12 Wayne Dalton Section Ext.Door +39.2/-43.7 16ft FL 9174.15 4. Roll up 5.Automatic 6. Other B. WINDOWS 1. Single Hung PGT 5400 Vinyl Single Window +50/-50 FL 1435 2. Horizontal slider PGT 5400 Vinyl Hor.Window +50/-50 FL 1844 3. Casement 4.Double hung 5. Fixed PGT 5400 Vinyl Fixed Window +50/-50 FL 5012 6.Awning 7. Pass-through 8.Projected 9.Mullion PGI Alum/Vinyl Mullions N/A FL 261 10.Wind Breaker 11.Store Front/Mitred Glass Kawneer Glass Windows Mitred Glass Windows +30/-30 FL 10008.1 12. Glass Block US Block/Hy-Lite Glass Block Window 70 PSF FL 185.12 Category/Subcategory Manufacturer Product Description Limitation of Use State O F F I I i C O P V C.PANEL WALL 1.Siding James Hardie Building Products,Inc. Lap Siding and Shingle Panels N/A FL 13192.2; 13192.4 James Hardie Building Products,Inc. Lap Siding and Shingles N/A FL 10477.1 FL 12098.3; 12098.1; Nichiha Corp. Lap Siding and Shingles N/A 12875.1 2. Soffits/Ceilings James Hardie Building Products,Inc. Soffit Panels N/A FL 13265.1 Nichiha Corp. Soffit Panels N/A FL 12098.4 3.EIFS 4.Storefronts Kawneer Glass Windows Mitred Glass +30/-30 FL 10008.1 5.Curtain walls 6.Wall louvers 7.Glass block 8.Membrane 9.Greenhouse 10. Synthetic Stucco 11.Other D. ROOFING PRODUCTS 1.Asphalt shingles GAF Corp. Timberline 30 year Arch Shingles N/A FL 10124.1 2.Underlayments Woodland Industries,Inc. Felt N/A FL 1814.12 Boral Roofing Roof Underlayment N/A FL 14317.1 3.Roofing fastners 4.Nonstructural metal roof Millennium Metals,Inc. Metal Roofing-M seam N/A FL 5211.3 R6 5.Built-up roofing 6.Modified bitumen 7.Single ply roofing 8.Roofing tiles 9.Roofing insulation 10.Waterproofing 11.Wood shingles/stakes Watkins Sawmill LTD. Wood Shingles and Shake N/A FL 13714.1 12.Roofing slate 13.Liquid applied roofing 14.Cement-adhesive coats 15.Roof tile adhesive 16.Spray applied polyurethane roof 17.Other Pli-Deck Walking deck membrane Ni:\ FL 12407.1 Category/Subcategory Manufacturer Product Description Limitation of Use StateI t riv E. SHUTTERS 1.Accordion 2.Bahama 3. Storm panels Town and Country Industries Storm shutters N/A FL 11963 4.Colonial 5.Roll-up 6.Equipment 7.Other F. STRUCTURAL COMPONENTS 1.Wood connector/anchor Simpson Strong Tie Per engineering 2.Truss plates Alpine Engineered Truss plate conn. _Per engineering 3.Engineered lumber Georgia Pacific Eng.Lumber FL 2023.1 4.Railing 5.Coolers-freezers 6.Concrete admixtures 7.Material 8.Insulation forms 9.Plastics 10.Deck-roof _ 11.Wall — -- 12.Sheds _ 13.Other G. SKYLIGHTS 1. Skylight Sun Tek FGC Skylite FL 2442 2.Other H.NEW EXTERIOR ENVELOPE PRODUCTS 1 7/16"Zip Wall-Structural 1 OSB(roof and wall);manufacturered by Huber Engineered Woods 2 In addition to completing the above list of manufacturers,product description and State approval number for the products used on this project,the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. "FICE COPY Audrey Regnier (Contractor Name) (Print Name) ( ignature) Company Name: Toll Brothers,Inc. Mailing Address: 160 Cape May Avenue City: Ponte Vedra State: FL Zip Code: 32081 Telephone Number: 904 217-0739 Fax Number: Cell Phone Number: 904-405-8969 Email Address: aregnier@tollbrothers.com OFFICE COPY FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Captiva 3854 Left SW Builder Name: Toll Brothers,Inc. Street: Lot 29 Atlantic Beach CC Permit Office: Duval City,State,Zip: Atlantic Beach ,FL, Permit Number: Owner: Toll Brothers,Inc. Jurisdiction: 261300 Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(4055.0 sqft.) Insulation Area i 2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=19.0 3836.70 ft2 b.Frame-Wood,Adjacent R=13.0 218.33 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (3157.0 sqft.) Insulation Area a.Under Attic(Vented) R=38.0 2840.00 ft2 6. Conditioned floor area above grade(ft2) 3854 b.Under Attic(Vented) R=19.0 317.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 • 11.Ducts R ft2 7. Windows(415.2 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 205 a. U-Factor: Dbl,U=0.34 415.22 ft2 b.Sup: Attic,Ret:Attic,AH:2nd Floor 6 186 SHGC: SHGC=0.27 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 18.0 SEER:14.00 c. U-Factor: N/A ft 2 b.Central Unit 42.0 SEER:14.00 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump • 18.0 HSPF:8.20 SHGC: b.Electric Heat Pump 42.0 HSPF:8.20 Area Weighted Average Overhang Depth: 6.494 ft. Area Weighted Average SHGC: 0.270 14.Hot water systems a.Natural Gas Tankless Cap: 1 gallons 8. Floor Types (3854.0 sqft.) Insulation Area EF:0.800 a.Slab-On-Grade Edge Insulation R=0.0 2882.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 697.00 ft2 None c.other(see details) R= 275.00 ft2 15.Credits Pstat Glass/Floor Area: 0.108 Total Proposed Modified Loads: 90.67 A C Total Baseline Loads: 98.20 M �7 I hereby certify that the plans and specifications covered by Review of the plans and c s o''' /HE S7d *n, this calculation are in compliance with the Florida Energy specifications covered by this ti :. a :,_ , c) Code. 1�� :-.,.,('..�f•:� $'.,+� y calculation indicates compliance i r ,,,,� o �,� .�-• • with the Florida Energy Code. s FY aurj ,, %\•0 a PREPARED BY: - J�A,Q�'� (�uir�75[i�r e0 Before construction is completed t u` ° , -:AR� S�(�':e•. ,-�?, DATE: 'a'- Ze -Z4/ s>K=._....._'6 ;p t� this building will be inspected for 1p�l-t r y, compliance with Section 553.908 I herebycertifythat this building,as designed, is in compliance Florida Statutes. vti� ,�'•. ;;r �''' g ,�,. with the Florida Ener Code. /�4041 ' 1/41Ti 'y�, ' t� e'`YOWNER/ GENT: ') - I ► 1 BUILDING OFFICIAL: fit DATE: ( (-9,- ( DATE: y. /'d01 er - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 6/20/2018 5:56 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: Captiva 3854 Left SW Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 3854 Lot# Owner Name: Toll Brothers,Inc. Total Stories: 2 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Toll Brothers,Inc. Rotate Angle: 0 Street: Lot 29 Atlantic Beach C Permit Office: Duval Cross Ventilation: No County: Duval Jurisdiction: 261300 Whole House Fan: No City,State,Zip: Atlantic Beach , Family Type: Single-family FL, New/Existing: New(From Plans) ' Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLEINT 32 93 70 75 1281 49 Medium BLOCKS • Number Name Area Volume 1 Block1 2882 28820 2 Block2 972 8748 SPACES ti Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated • 1 Main 2882 28820 Yes 4 3 1 Yes Yes Yes 2 2nd Floor 972 8748 No 1 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet :../ 1 Slab-On-Grade Edge Insulatio Main 204 ft 0 2882 ft2 ____ 0 0 1 V/ 2 Floor Over Other Space 2nd Floor ____ ____ 697 ft2 0 0 0 1 3 Floor over Garage 2nd Floor ____ ____ 275 ft2 0 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) V 1 Gable or Shed Metal 3420 ft2 658 ft2 Medium 0.6 N 0.9 No 0 22.6 /✓ ATTIC v / # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 3157 ft2 N N 6/20/2018 5:56 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 CEILING Vj # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floor 38 Blown 801 ft2 0.11 Wood 2 Under Attic(Vented) Main 38 Blown 2039 ft2 0.11 Wood 3 Under Attic(Vented) 2nd Floor 19 Blown 171 ft2 0.11 Wood 4 Under Attic(Vented) Main 19 Blown 146 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below . • ' • ' - •- R-Value Ft In Ft In ArPa R-value Fraction Ahcnr Grade% 1 SW Exterior Frame-Wood 2nd Floor 19 23 2 9 0 208,5 ft2 0 0.23 0.6 0 1MSW Exterior Frame-Wood 2 ain 19 22 8 10 0 226,7 ft2 0 0.23 0.6 0 3 SE Exterior Frame-Wood 2nd Floor 19 58 6 9 0 526.5 ft2 0 0.23 0.6 0 4 SE Exterior Frame-Wood Main 19 84 6 10 0 845.0 ft2 0 0.23 0.6 0 5 NE Exterior Frame-Wood 2nd Floor 19 23 2 9; 0 208.5 ft2 0 0.23 0.6 0 6 NE Exterior Frame-Wood Main 19 45 0 10 0 450.0 ft2 0 0.23 0.6 0 7 NW Exterior Frame-Wood 2nd Floor 19 58 6 9 0 526.5 ft2 0 0.23 0.6 0 NW Exterior Frame-Wood Main 19 84 6 10 0 845.0 ft2 0 0.23 0.6i 0 9 SW Garage Frame-Wood Main 13 21 10 10 0 218.3 ft2 0 0.23 .0.6 0 • DOORS # Ornt Door Type Space Storms U-Value Width Height Area ti Ft In Ft In ✓ 1 SW Insulated Main None 4 3 8 24 ft2 2 SW Insulated Main None .4 2 8 821.3 ft2 WINDOWS - Orientation shown is the entered,Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SW 1 Vinyl Low-E Double Yes 0.34 0.27 N 14.2 ft2 1 ft 4 in 2 ft 0 in None Exterior 5 2 SW . 2 Vinyl Low-E Double Yes 0.34 0.27 N 16.0 ft2 14 ft 4 in 2 ft 0 in None Exterior 5 3 SW 2 Vinyl Low-E Double Yes 0.34 0.27 N 36.0 ft2 7 ft 4 in 2 ft 0 in Drapes/blinds Exterior 5 4 SE 4 Vinyl Low-E Double Yes 0.34 0.27 N 24.0 ft2 1 ft 4 in 2 ft 0 in None Exterior 5 5 SE 4 Vinyl Low-E Double Yes 0.34 ' 0.27 N 4.0 ft2 1 ft 4 in 2 ft 0 in None Exterior 5 6 SE 4 Vinyl Low-E Double Yes 0.34 ' 0.27 N 12.0 ft2 11 ft 0 in 2 ft 0 in None Exterior 5 • 7 NE 6 Vinyl Low-E Double Yes 0.34 0.27 N 72.0 ft2 17 ft 6 in 2 ft 0 in None Exterior 5 8 NE 6 Vinyl Low-E Double Yes 0.34 0.27 N 36.0 ft2 9 ft 6 in 2 ft 0 in None Exterior 5 9 NE 6 Vinyl Low-E Double Yes 0.34 0.27 N 60.0 ft2 1 ft 4 in 2 ft 0 in Drapes/blinds Exterior 5 10 NW 7 Vinyl Low-E Double Yes 0.34 0.27 N 30.0 ft2 1 ft 4 in 2 ft 0 in Drapes/blinds Exterior 5 . 11 SE 3 Vinyl Low-E Double Yes 0.34 0.27 N 45.0 ft2 1 ft 4 in 2 ft 0 In None Exterior 5 12 NW 8 Vinyl Low-E Double Yes 0.34 0.27 N 36.0 ft2 1 ft 4 in 2 ft 0 in None Exterior 5 1i, 13 NW 8 Vinyl Low-E Double Yes 0.34 0.27 N 15.0 ft2 1 ft 4 in 2 ft 0 in None Exterior 5 14 'SE 4 Vinyl Low-E Double Yes 0.34 0.27 N 15.0 ft2 11 ft 0 in 2 ft 0 in Drapes/blinds Exterior 5 6/20/2018 5:56 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 GARAGE V / # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation L.V 1 579 ft2 579 ft2 64 ft 9 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000434 4382.9 240.62 452.52 .411 7 • HEATING SYSTEM V/ # System Type Subtype Efficiency Capacity Block Ducts / 1 Electric Heat Pump/ None HSPF:8.2 18 kBtu/hr . 2 sys#1 2 Electric Heat Pump/ None HSPF:8.2 42 kBtu/hr 1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 14 18 kBtu/hr 540 cfm 0.74 • 2 sys#1 2 Central Unit/ Split SEER: 14 42 kBtu/hr 1260 cfm 0.8 1 sys#2 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation • 1 Natural Gas Tankless Exterior 0.8 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / --Supply-- —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool �/ 1 Attic 6 205 ft2 Attic 154 ft' Default Leakage 2nd Floor (Default) (Default) 1 1 2 Attic 6 186 ft2 Attic 86 ft' Default Leakage 2nd Floor (Default) (Default) 2 2 6/20/2018 5:56 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling Jan Feb Mar A r Ma X Jun X Jul X Au X Se Oct Nov Dec HeatingilX�Jan lX�Feb b Xi Mar [X Apr May Jun Jul Aug Sep [X Oct X Nov LX Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 ' 78 78 78 • 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 - 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 • PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION . Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System • None 0 0 0 2-Electric Heat Pump 0% 2-Central Unit 6/20/2018 5:56 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 92 The lower the EnergyPerformance Index,the more efficient the home. Lot 29 Atlantic Beach CC, Atlantic Beach , FL, i I 1. New construction or existing • New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 3836.70 ft' b.Frame-Wood,Adjacent R=13.0 218.33 ft' 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=38.0 2840.00 ft2 6. Conditioned floor area(ft2) 3854 b.Under Attic(Vented) R=19.0 317.00 ft2 7. Windows** Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.34 415.22 ft2 11.Ducts R ft2 a.Sup:Attic, Ret:Attic,AH:2nd Floor 6 205 SHGC: SHGC=0.27 b.Sup: Attic, Ret:Attic,AH:2nd Floor 6 186 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 18.0 SEER:14.00 SHGC: b.Central Unit 42.0 SEER:14.00 d. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 6.494 ft. a.Electric Heat Pump 18.0 HSPF:8.20 b.Electric Heat Pump 42.0 HSPF:8.20 Area Weighted Average SHGC: 0.270 8. Floor Types Insulation Area 14.Hot water systems a.Slab-On-Grade Edge Insulation R=0.0 2882.00 ft2 a.Natural Gas Cap: 1 gallons b.Floor Over Other Space R=0.0 697.00 ft2 EF:0.8 c.other(see details) R= 275.00 ft2 b. Conservation features None 15.Credits Pstat , -...... I certify that this home has complied with the Florida Energy Efficiency Code for Building �0,""' 4i�. Construction through the above energy saving features which will be installed (or exceeded) o'r'oI"�xEsrg:4- 4,..+ in this home before final inspection. Otherwise, a new EPL Display Card will be completed ?�3`: %, _, ';..' based on installed Co7 compliant features. P y p =ti/��" `,'.„;,v- •k,;_...� •_*mac Builder Signature: 1 Ni ; 9 Date: 1 1 Address of New Home: p Cit /FL Zi a t'. -. `�S:,� Ra--i--01-i Guy"I C. I�C�I✓► Q� y P• .Vl�'!C, bG;Lj �„.„,„0,..,,,,,,,,..„,� P. � ,� - .„ ,1,... ... *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com forinformation and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/20/2018 5:56 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: Lot 29 Atlantic Beach CC Permit Number: Atlantic Beach , FL, MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. • Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate.Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3. Interior doors,if installed at the time of the test,shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems,if installed at the time of the test,shall be turned off. 6. Supply and return registers,if installed at the time of the test,shall be fully open. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air Ieakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 L/s/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 6/20/2018 5:56 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where It passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes Installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. R402.4,5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential:All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1 Controls. SECTION R403 SYSTEMS R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or (7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing(Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1, Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The controls shall automatically tum off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 6/20/2018 5:56 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017)Complian Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 Y2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies(Mandatory). R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of • combustion types of service water-heating systems to be turned off. R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation, Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in Installed solar water-heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential,or Florida Building Code, Mechanical,as applicable,or with other approved means of ventilation including:Natural,Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3' If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10 otherwise. R403.7 Heating and cooling equipment(Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not Include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMUN (CFM) (CFM/WATT) (CFM) Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt <90 Bathroom,,utility room 90 2.8 cfm/watt Any For SI:1 cfm=28.3 L/min. a. When tested in accordance with HVI Standard 916 6/20/2018 5:56 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multiple-family residential equipment sizing may be selected so that Its cooling capacity Is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature Is above 40°F(4.8°C). R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-firedpool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 6/20/2018 5:56 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Compile Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas(Mandatoryl)he energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception:Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory).Fuel gas lighting systems shall not have continuously burning pilot lights. 6/20/2018 5:56 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Compile Page 5 of 5 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Captiva 3854 Left SW Builder Name: Toll Brothers, Inc. Street: Lot 29 Atlantic Beach CC Permit Office: Duval City,State,Zip: Atlantic Beach ,FL, Permit Number: Owner: Toll Brothers, Inc. Jurisdiction: 261300 Design Location: FL,Jacksonville COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and • continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spas. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind nioina and wirina. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover elates and walls or ceilings a. In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 6/20/2018 5:56 PM EnergyGauge®USA-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 FORM R405-2017 Envelope Leakage Test Report Performance FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Performance Method Project Name: Captiva 3854 Left SW Builder Name: Toll Brothers,Inc. Street: Lot 29 Atlantic Beach CC Permit Office: Duval City,State,Zip: Atlantic Beach , FL, Permit Number: Design Location: FL,Jacksonville Jurisdiction: 261300 Cond.Floor Area:: 3854 sq.ft. Cond.Volume: 37568 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: Single or Multi Point Test Data Required ACH(50)from HOUSE PRESSURE FLOW: FORM R405-2017 : 1 Pa cfm 2 Pa cfm Tested ACH(50) *: 3 Pa cfm 4 Pa cfm *Tested leakage must be less than or equal to the required ACH(50) shown on Form R405-2017 for 5 Pa cfm this building. If the tested ACH(50)is less than 3 the building must have a mechanical ventilation 6 Pa cfm system. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2...Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either Individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3. Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers, if installed at the time of the test,shall be fully open. 4,444 I hereby certify that the above envelope leakage Testing shall be conducted by either ' .�.�...E...... performance results demonstrate compliance individuals as defined in Section ' %a f s O tL 553.993 5 or 7 , °'fo4r,r�_= '6 \„ with Florida Energy Code requirements in O O Florida Statutes or , , accordance with Section R402.4.1.2. individuals licensed as set forth in rn,+ a on O�. Section 489.105(3)(f), (g),or(i)or an w fi,"-�, "'�. ; approved third party.A written report ofij ;y•z the results of the test shall be signed SIGNATURE: ` ;` by the third party conducting the test �,- and provided to the code official. Q ' •••••"' .„xi PRINTED NAME: '`wt „?? W '' DATE: BUILDING OFFICIAL: DATE: 6/20/2018 5:56 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 , - Project Summary Job: Lot 29ABCC 7, �, `` 1st Date: ' oiatitu Y, By: Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie©mcgowansac.com Web:www.mcgowansac.com License:CMC1... Project Information For: Toll Architecture 2966 Commerce Park Drive Suite 100, Orlando, FL 32819 Phone:407-248-5800 Fax:407-248-5899 Notes: Captiva Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 24 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 29120 Btuh Structure 22988 Btuh Ducts 3894 Btuh Ducts 4862 Btuh Central vent(0 cfm) 0 Btuh -Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 33014 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 27850 Btuh Method Blower door Latent Cooling Equipment Load Sizing Shielding/stories 3(partial)/1 Pressure/AVF 50 Pa/4532 cfm Structure 6143 Btuh Ducts 847 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft') 2882 2882 Equipment latent load 6991 Btuh Volume (ft3) 28348 28348 Air changes/hour 0.44 0.26 Equipment Total Load (Sen+Lat) 34841 Btuh Equiv.AVF (cfm) 208 125 Req. total capacity at 0.70 SHR 3.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB0420000A0 Cond CH14NB0420000A0 AHRI ref 9162578 Coil FB4CNP042L AHRI ref 9162578 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 28000 Btuh Heating output 41000 Btuh @ 47°F Latent cooling 12000 Btuh Temperature rise 30 °F Total cooling 40000 Btuh Actual air flow 1225 cfm Actual air flow 1225 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.80 Capacity balance point=27°F Backup: Input=8 kW, Output=28515 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - 44 wrlghtsoft„ 2018-Jun-2017:55:06 - Comfort Builder by Wrightsoft 18.0.19 RSU03444 Page 1 ACQK ...Brothers\Captive 3854 left SW-Lot 29 ABCC.rup Calc=MJ8 Front Door faces:SW "� ,itProject Summary Date: Lot 29ABCC i.:_.. � �` 2nd AV By: Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax:904-278-0366 Email.saldie@mcgowansac.com Web:www.mcgowansac.com License:CMC1... Pro"ect Information For: Toll Architecture 2966 Commerce Park Drive Suite 100, Orlando, FL 32819 Phone:407-248-5800 Fax:407-248-5899 Notes: Captiva Desi•n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 24 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 12539 Btuh Structure 9950 Btuh Ducts 1242 Btuh Ducts 1578 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 13782 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 11578 Btuh Method Blower door Latent Cooling Equipment Load Sizing Shielding/stories 3(partial)/1 Pressure/AVF 50 Pa/4532 cfm Structure 3732 Btuh Ducts 320 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 972 972 Equipment latent load 4003 Btuh Volume (ft3) 9999 9999 Air changes/hour 0.86 0.51 Equipment Total Load (Sen+Lat) 15581 Btuh Equiv.AVF (cfm) 143 86 Req. total capacity at 0.70 SHR 1.4 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB0180000A0 Cond CH14NB0180000A0 AHRI ref 9162108 Coil FB4CNP018L AHRI ref 9162108 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 12460 Btuh Heating output 17600 Btu h @ 47°F Latent cooling 5340 Btuh Temperature rise 31 °F Total cooling 17800 Btuh Actual air flow 525 cfm Actual air flow 525 cfm Air flow factor 0.038 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.74 Capacity balance point=27°F Backup: Input=3 kW, Output=8599 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrisstrtsoft` 2018-Jun-20 17:55:06 4A... .., - Comfort Builder by Wrightsoft 18.0.19 RSU03444 Page 2 Acc . ...Brothers\Captiva 3854 left SW-Lot 29 ABCC.rup Calc=MJ8 Front Door faces:SW N e 2nd Floor 10 1s,. Nos 751N, , Wilt,, ,a 16 x 16 MIill14" 14" 12" 6x12 open to'elow 7 loft 2-way 3"Fan stair Ate bath 3 6x14 ww�ww"�w.......�- .,. bed 4 8 .. 12x6 7' 12 x 12 10" r i living Job#: Lot 29 ABCCMcGowan's Heating & Air Conditionir Scale: 1 : 118 Performed by Saldie Guintivano for: Page 1 Toll Architecture 11320 E.Phillips Parkway Dr. Comfort Builder by Wrightsoft 2966 Commerce Park Drive Suite 100 Jacksonville,FL 32256 18.0.19 RSU03444 Orlando,FL 32819 Phone:904-278-0339 Fax:904-278-0366 20 Phone:407-248-5800 Fax:407-248-5899 2018-Jun-20 of 29 ABCC.rup saldie@mcgowansac.com .a 3854 left SW-Lot 29 ABCC.rup N / t} fA 1st Floor master 10x6 16x16 12" 10x6 10x6 6" • 6" 6" Mining, 1- 10x6 4 x 8 hers 6" 3" ww AN 0.■ 4,. great rir.,.,10g8 10 4x8 St 4" m bath 3"FAN 0 0 10x6 00 S./W 6" J ... 12x6 12" 12x12 7" kitchen 14" 9" 10x6 bed 3 6" 10' ,.-41,11P"...,. '41311.1vii 11III W 11 24 x 18 ° 8x4Pdfltly10x6 +.8x4 6x10 . 16" 4„ A. 6" 4�, n ink 2 4HUR 5., �J 4a• MO . . ROOLunrh,rsi 10x6 12 x 12 10 �11OX, 1r6" a 8 10" study halt stairs b.h 2 I\ 8x4 3"Fan Bri 4„ wic 3 sink 1 12x12 8x4 9„ 8x', 10x6 ,., a.. 5" 12x6,.. ,,.,:•.,,,0 7' garage foyer bed 2 ..-7,) Job#: Lot 29 ABCCMcGowan's Heating & Air Conditionir Scale: 1 : 118 Performed by Saldie Guintivano for: Page 2 Toll Architecture 11320 E.Phillips Parkway Dr. Comfort Builder by Wrightsoft 2966 Commerce Park Drive Suite 100 Jacksonville,FL 32256 18.0.19 RSU03444 Orlando,FL 32819 Phone:904-278-0339 Fax:904-278-0366 Phone.407-248-5800 Fax:407-248-5899 201 20 17:55:20 left S www.mcgowansac.com saldie©mcgowansac.com .,.a 3854 left SW-Lot 29 ABCC.rup Manual S Compliance Report Job: Lot 29ABCC Date: itka,t4tUt i 1st By: Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone 904-278-0339 Fax:904-278-0366 Email:saldie©mcgowansac.com Web:www.mcgowansac.corn License:CMC1... Project Information For: Toll Architecture 2966 Commerce Park Drive Suite 100, Orlando, FL 32819 Phone:407-248-5800 Fax: 407-248-5899 Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 27850 Btuh Entering coil DB: 75.8°F Outdoor design WB: 80.2°F Latent gain: 6991 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 34841 Btuh Indoor RH: 50% Estimated airflow: 1225 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH 14NB0420000A0+FB4CNP042L Actual airflow: 1225 cfm Sensible capacity: 28717 Btuh 103%of load Latent capacity: 7549 Btuh 108%of load Total capacity: 36265 Btuh 104%of load SHR: 79% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 33014 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH 14NB0420000A0+FB4CNP042L Actual airflow: 1225 cfm Output capacity: 32370 Btuh 98%of load Capacity balance: 27 °F Supplemental heat required: 643 Btuh Economic balance: -50 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1225 cfm Output capacity: 8.4 kW 86%of load Temp. rise: 44 °F Meets all requirements of ACCA Manual S. wrlghtsoft 2018-Jun-20 17:55:06 '"+ Comfort Builder by Wrightsoft 18.0.19 RSU03444 Page 1 / ...Brothers\Captiva 3854 left SW-Lot 29 ABCC.rup Calc=MJ8 Front Door faces:SW Manual S Compliance Report Job: Lot 29 ABCC Date: �,(i1Ht`ftlr' I 2nd By: Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie©mcgowansac.com Web:www.mcgowansac.com License.CMC1... Project Information For: Toll Architecture 2966 Commerce Park Drive Suite 100, Orlando, FL 32819 Phone:407-248-5800 Fax: 407-248-5899 Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 11578 Btuh Entering coil DB: 75.9°F Outdoor design WB: 80.2°F Latent gain: 4003 Btuh Entering coil WB: 63.0°F Indoor design DB: 75.0°F Total gain: 15581 Btuh Indoor RH: 50% Estimated airflow: 525 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH 14NB0180000A0+FB4CNP018L Actual airflow: 525 cfm Sensible capacity: 11793 Btuh 102%of load Latent capacity: 3996 Btuh 100%of load Total capacity: 15789 Btuh 101%of load SHR: 75% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 13782 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH 14NB0180000A0+FB4CNP018L Actual airflow: 525 cfm Output capacity: 13477 Btuh 98%of load Capacity balance: 27 °F Supplemental heat required: 305 Btuh Economic balance: -32 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 525 cfm Output capacity: 2.5 kW 62%of load Temp. rise: 48 °F Meets all requirements of ACCA Manual S. wrigi�tsoft' 2018-Jun-20 17:55:06 j=� Comfort Builder by Wrightsoft 18.0.19 RSU03444 Page 2 AC ...Brothers\Captiva 3854 left SW-Lot 29 ABCC.rup Calc=MJ8 Front Door faces:SW Duct System Summary Job: Lot 29 ABCC tDate: Afr��yv � . 1st By: Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax:904-278-0366 .Email:saldie@mcgowansac.corn Web:www.mcgowansac.corn License:CMC1... Project Information For: Toll Architecture 2966 Commerce Park Drive Suite 100, Orlando, FL 32819 Phone:407-248-5800 Fax: 407-248-5899 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.247/0.143 in H2O 0.247/0.143 in H2O Lowest friction rate 0.058 in/100ft 0.058 in/100ft Actual air flow 1225 cfm 1225 cfm Total effective length (TEL) 677 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln(ft) Trunk bath 2 h 1100 41 20 0.060 4.0' Ox 0 VIFx 89.7 325.0 st9 bed 2 h 3898 145 117 0.062 7.0 Ox 0 VIFx 85.2 315.0 st9 bed 3 c 1711 74 75 0.077 7.0 Ox 0 VIFx 59.7 260.0 st4 dining h 4328 161 143 0.079 6.0 Ox 0 VIFx 55.2 260.0 st4 foyer h 2156 80 76 0.058 5.0 Ox 0 VIFx 99.7 330.0 st9 great c 1716 57 75 0.077 6.0. Ox 0 VIFx 59.3 260.0 st4 great-A c 1716 57 75 0.080 6.01 Ox 0 VIFx 49.1 260.0 st4 great-B c 1716 57 75 0.096 6.01 Ox 0 VIFx 37.8 220.0 st3 hers h 1009 37 20 0.065 4.0. 0x 0 VIFx 68.7 310.0 st5 kitchen c 3339 126 147 0.077 6.0 0x 0 VIFx 60.0 260.0 st4 laundry ' c 1743 61 77 0.093 5.0 Ox 0 VIFx 44.7 220.0 st3 m bath h 1493 55 44 0.067 5.0. Ox 0 VIFx 65.8 305.0 st5 master ' h 2467 92 86 0.065 6.0 Ox 0 VIFx 74.7 305.0 st5 master-A h 2467 92 86 0.066 6.0 Ox 0 VIFx 72.0 305.0 st5 pantry-A c 88 2 4 0.097 4.0 Ox 0 VIFx 36.4 220.0 st3 pwdr c 7 0 0 0.072 4.0 Ox 0 VIFx 67.3 275.0 st8 sink 1 h 761 28 27 0.060 4.0 Ox 0 VIFx 86.2 325.0 st9 sink 2 h 761 28 27 0.071 4.0 Ox 0 VIFx 67.3 280.0 st8 study c 1150 31 51 0.094 6.0 Ox 0 VIFx 39.3 225.0 st3 We c 38 1 2 0.066 4.0 Ox 0 VIFx 69.2 305.0 st5 wic 3 c 7 0 0 0.060 4.0 Ox 0 VIFx 87.7 325.0 st9 wrightsoft" 2018-Jun-20 17:55:06 -- ,. ,..„,<.,.,,.......... Comfort Builder by Wrightsoft 18.0.19 RSU03444 Page 1 AC ...Brothers\Captiva 3854 left SW-Lot 29 ABCC.rup Calc=MJ8 Front Door faces:SW Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st8 Peak AVF 322 266 0.058 591 10.0 0 x 0 ViniFlx st7 st9 Peak AVF 294 240 0.058 539 10.0 0 x 0 VinIFIx st8 st3 Peak AVF 903 959 0.065 897 14.0 0 x 0 VinIFIx st2 st7 Peak AVF 322 266 0.058 591 10.0 0 x 0 ViniFlx st6 st2 Peak AVF 1225 1225 0.058 877 16.0 0 x 0 ViniFlx st6 Peak AVF 322 266 0.058 591 10.0 0 x 0 ViniFlx st2 st5 Peak AVF 277 236 0.065 507 10.0 0 x 0 VinIFIx st4 st4 Peak AVF 752 752 0.065 957 12.0 0 x 0 VinIFIx st3 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb7 Ox 0 494 528 247.6 0.058 672 12.0 Ox 0 VIFx rt4 rb6 Ox 0 190 228 243.7 0.059 516 9.0 Ox 0 VIFx rt4 rb4 Ox 0 247 229 182.4 0.078 177 16.0 Ox 0 VIFx rt3 rb2 Ox 0 294 240 180.6 0.079 842 8.0 Ox 0 VIFx rt3 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name ' Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt4 Peak AVF 684 756 0.058 707 14.0 0 x 0 VinlFlx rt3 rt3 Peak AVF 1225 1225 0.058 693 18.0 0 x 0 VinlFlx rt2 rt2 ' Peak AVF 1225 1225 0.058 693 18.0 0 x 0 VinIFIx - wrightsoft' 2018-Jun-20 17:55:06 ": Comfort Builder by Wrightsoft 18.0.19 RSU03444 Page 2 A k ...Brothers\Captiva 3854 left SW-Lot 29 ABCC.rup Calc=MJ8 Front Door faces:SW 77* .. Duct System Summary Da e• Lot 29 ABCC ,,'<r,C(44)'Ut:i -7c::1-11 - 2nd By: Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax 904-278-0366 Ernail:saldie©mcgowansac.corn Web:www.mcgowansac.corn License:CMC1_.. Project Information For: Toll Architecture 2966 Commerce Park Drive Suite 100, Orlando, FL 32819 Phone:407-248-5800 Fax: 407-248-5899 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.220/0.170 in H2O 0.220/0.170 in H2O Lowest friction rate 0.108 in/100ft 0.108 in/100ft Actual air flow 525 cfm 525 cfm Total effective length (TEL) 362 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk bath 3-A h 933 36 28 0.112 4.0 Ox 0 VIFx 37.3 160.0 st1 bed 4 c 3821 165 174 0.108 • 8.0 Ox 0 VIFx 44.0 160.0 st1 living c 2682 119 122 0.114 7.0 Ox 0 VIFx 33.6 160.0 st1 living-A c 2682 119 122 0.108 7.0 Ox 0 VIFx 43.6 160.0 st1 loft-A h 2239 85 79 0.108 7.0 Ox 0 VIFx 44.5 160.0 st1 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 525 525 0.108 668 12.0 0 x 0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb5 Ox 0 205 201 157.6 0.108 375 10.0 Ox 0 VIFx rt1 rb3 Ox 0 320 324 112.5 0.151 303 14.0 Ox 0 VIFx rt1 wrightsoft 2018-Jun-20 17:55:06 ACO► Comfort Builder by Wrighlsoft 18.0.19 RSU03444 Page 3 A ...Brothers\Captiva 3854 left SW-Lot 29 ABCC.rup Calc=MJ8 Front Door faces:SW Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 Peak AVF 525 525 0.108 491 14.0 0 x 0 VinlFlx wrigAtsoft` 2018-Jun-20 17:55:06 Comfort Builder by Wrightsoft 18.0.19 RSU03444 Page 4 ACZA ...Brothers1Captiva 3854 left SW-Lot 29 ABCC.rup Calc=MJ8 Front Door faces:SW \BUCK Engineering Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Evaluation Report "M-Seam" Metal Roof Assembly Manufacturer: Millennium Metals, Inc. 10200 Eastport Road Jacksonville, FL 32218 (877) 358-7663 for Florida Product Approval # FL 5211.3 R6 Florida Building Code 5th Edition (2014) Per Rule 61G20-3 Method: 1 - D Category: Roofing Sub - Category: Metal Roofing Product: "M-Seam" Material: Steel Panel Thickness: 26 gauge, (Minimum) Panel Width: 16" Support: Wood Deck Digitally signed by James L.Buckner,P.E. Electronically signed and sealed documents shall comply with the provisions of FAC Rule Prepared by: 61615-23. \I1IIII James L. Buckner, P.E., SECS .�` �s ••-: Buck''% Florida Professional Engineer # 31242 vCENSF '•..•. Florida Evaluation ANE ID: 1916 = No 31242 • _-C * w_ Project Manager: Youry Demosthenes ,70 : : Lu Report No. 15-104-M-S6W-ER i0i(� STATE OF tyz: (Revises 12-117-M-S6W-ER) SS, .FcoR�oP.• 'Gam``: Date: 7/ 1/ 15 ''/s!ONA���\`�� Contents: Evaluation Report Pages 1—7 CBUCK, Inc. 2015.07.01 11:03:27-04'00' 1399 N. Killian Drive,Suite 4,West Palm Beach,Florida 33403 Phone:(561)491-9927• Email:cbuck@cbuckinc.net•Website:www.cbuckinc.net \ FL#: FL 5211.3-R6 Date: 7/1/15 #'"�" Report No.: 15-104-M-S6W-ER u K n n n Page 2 of 7 Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Manufacturer: Millennium Metals, Inc. Product Name: "M-Seam" Product Category: Roofing Product Sub-Category Metal Roofing Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) Product/System "M-Seam" Description: 26 gauge Minimum, Steel roof panel mechanically attached to Plywood Deck with screws. Product Assembly as Refer to Page 4 of this report for product assembly components/materials & Evaluated: standards: 1. Roof Panel 2. Fasteners 3. Underlayment 4. Insulation (Optional) Support: Type: Wood Deck (Design of support and its attachment to support framing is outside the scope of this evaluation.) Description: • 15/32 (min.) or 19/32" or greater plywood, • or Wood plank(min. specific gravity of 0.42) Slope: Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2, applicable code sections and in accordance with manufacturer's recommendations. Performance: Wind Uplift Resistance: • Design Uplift Pressure: Refer to Table "A" (Refer to"Table A" attachment details herein) FL#: FL 5211.3-R6 Date: 7/1/ 15 CSUCK EnginemeringPage rt No.:3-1 7-M-S6W-ER Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Performance Standards: The product described herein has demonstrated compliance with: • UL580-06—Test for Uplift Resistance of Roof Assemblies • UL 1897-04—Uplift test for roof covering systems Standards Equivalency: • The UL 580-94 standard version used to test the evaluated product assembly is equivalent to UL580-06 standard version adopted by the Florida Building Code 5th Edition (2014). • The UL 1897-98 standard version used to test the evaluated product assembly is equivalent to UL1897-04 standard version adopted by the Florida Building Code 5th Edition (2014). Code Compliance: The product described herein has demonstrated compliance with Florida Building Code 5th Edition (2014),Section 1504.3.2. Evaluation Report This product evaluation is limited to compliance with the structural requirements of Scope: the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Limitations and • Scope of"Limitations and Conditions of Use"for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval" contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under"Optional Statewide Approval". • Option for application outside "Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade& Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization #: QUA 1824). FL#: FL 5211.3-R6 Date: 7/ 1/ 15 \cE31JCK ;. r el n Page rt No.: 5M S6W ER 40f 7 SpPCIalty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Components/Materials Roof Panel: "M-Seam" (by Manufacturer): Material: Steel Thickness: 26 gauge Minimum Panel Width: 16" (max.) Coverage Rib Height: 1" Yield Strength: 40 ksi min. Corrosion Resistance: In compliance with FBC Section 1507.4.3: • ASTM A792 coated, or • ASTM A653 G90 galvanized steel Fastener: Type: Pancake-Head Wood Screw Size : #10 x 1" Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4 Standard: Per ANSI/ASME B18.6.4 Components/Materials Underlayment: (by Others): Material and application shall be in compliance with FBC Section 1507.4.5.1 and 1507.4.5.2, applicable codes and in accordance with manufacturer's recommendations. Insulation (Optional): Type: Rigid Insulation Board Thickness: 3" (max.) Properties: Density: 2.25 pcf(lbs/ft3) min. Or Compressive Strength: 20 psi min. Insulation Notes: • Rigid Insulation shall meet minimum density OR compressive strength. • Insulation shall comply with FBC Section 1508. When insulation is incorporated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/16". FL#: FL 5211.3-R6 Date: 7/ 1/ 15 Report No.: 5 15-104- 7 M-S6W-ER Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Installation: Installation Method: (Refer to drawings on Pages 6-7 of this report.) • Fastener spacing: Refer to Table"A" Below (along the length of the panel) • Rib Interlock: Snap Lock (Panel ribs shall be fully engaged to form an integral interlock. ) • Minimum fastener penetration thru bottom of support, 3/16". • For panel construction at the end of panels, refer to manufacturer's instructions and any site specific design. TABLE "A" ALLOWABLE LOADS METHOD 1: METHOD 2: * Design Pressure: -84.25 PSF -91.75 PSF Deck Thickness: 15/32" or 19/32" 15/32" or 19/32" Fastener Spacing: 8" 4" *Allowable design pressure for allowable stress design(ASD) with a margin of safety of 2 to 1. Install the "M-Seam" roof panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 5th Edition (2014). The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Referenced Data: 1. UL580-94& UL 1897-98 Uplift Test By Hurricane Test Laboratory, LLC(FBC Organization#TST ID: 1527) Report#: 0232-0508-05, Report Date:6/29/05, Specimens#1-3 2. Quality Assurance By Keystone Certifications, Inc. (QUA ID: 1824) Millennium Metals Licensee#423 3. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) 4. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) \ FL#: FL 5211.3-R6 \\ CBUCK a :Engineering 4 Page rt No.: 65 7 M-S6W-ER Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Installation Method Millennium Metals "M-Seam" Roof Panel Attached to Wood Deck Profile Drawings 1" 16"CoverageH _____L_\_i__ i L --No, •,—. Optional Striations 3/4" Typical Panel Profile View 16"o.c. ia-? gir\LIntegral Snap Lock #10 Pancake-Head Screw ---LI— 3/16"min. penetration thru deck 7- ' ')'I ' <:' WI i Typical Assembly Profile View FL#: FL 5211.3-R6 i r� r Date: 7/ 1/ 15 CBUCK n I ee it c Page Report No.: 15-104 7- S6W-ER Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization 118064 Installation Method Millennium Metals "M-Seam" Roof Panel Attached to Wood Deck Fastener: #10 Pancake-Head Screw "M-Seam"Roof Panel �I -- — / i i r / r , / / 8?Typical /// Deck:--'—✓v---�---`�- Insulation: -15/32"or 19/32"or greater Plywood,or (Optional)3"max or 25 psi min. -Wood plank Typical Assembly Profile View TABLE "A" ALLOWABLE LOADS METHOD 1: METHOD 2: * Design Pressure: -84.25 PSF -91.75 PSF Deck Thickness: 15/32" or 19/32" 15/32"or 19/32" Fastener Spacing: 8" 4" *Allowable design pressure for allowable stress design(ASO) with a margin of safety of 2 to 1.