771 PARADISE LN - NEW HOME PERMIT iiit (.... 0,...„.„.,..„,e4 ';s1 CITY OF ATLANTIC BEACH ;-�.. ) 800 SEMINOLE ROAD ,,,,,,, ATLANTIC BEACH, FL 32233 ' -!,;3 S)' INSPECTION PHONE LINE 247-5814 RESIDENTIAL - NEW SINGLE FAMILY RESIDENCE MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES18-0250 Description: Estimated Value: 342279.05 Issue Date: 8/13/2018 Expiration Date: 2/9/2019 PROPERTY ADDRESS: Address: 771 PARADISE LN RE Number: 172376 0180 PROPERTY OWNER: Name: SPRINGFIELD LBUILDERS LLC Address: 1881 BEACH AVE ATLANTIC BEACH, FL 32233 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: Address: Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. o Permit Conditions 017 City of Atlantic Beach Permit Number: RES18-0250 Description: Applied:7/19/2018 Approved:8/7/2018 Site Address:771 PARADISE LN Issued:8/13/2018 Finaled: City,State Zip Code:ATLANTIC BEACH, FL 32233 Status: ISSUED Applicant:<NONE> Parent Permit: Owner:SPRINGFIELD LBUILDERS LLC Parent Project: Contractor:<NONE> Details: LIST OF CONDITIONS SEQ NO ADDED DATE REQUIRED DATE SATISFY DATE TYPE STATUS DEPARTMENT CONTACT REMARKS 1 7/24/2018 UNDERGROUND WATER SEWER INFORMATIONAL UTILITIES PUBLIC UTILITIES Kayle Moore Notes: Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed,call 247-5834. 2 7/24/2018 METER BOX SEWER CLEAN OUT INFORMATIONAL PUBLIC UTILITIES Kayle Moore Notes: Ensure all meter boxes,sewer cleanouts and valve covers are set to grade and visible. 3 7/24/2018 RT1 SEWER CLEANOUT INFORMATIONAL PUBLIC UTILITIES Kayle Moore Notes: A sewer cleanout must be installed at the property line. Cleanout must be covered with an RT1 concrete box with metal lid. Cleanout to be set to grade and visible. 4 8/2/2018 DRIVEWAY APRON INFORMATIONAL PUBLIC WORKS Scott Williams Notes: All concrete driveway aprons must be 5"thick,4000 psi,with fibermesh from edge of pavement to the property line. Reinforcing rods or mesh are not allowed in the right-of-way. (Commercial driveways-6"thick). 5 8/2/2018 EROSION CONTROL INSTALLATION INFORMATIONAL PUBLIC WORKS Scott Williams Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line(247- 5814)to request an Erosion and Sediment Control Inspection prior to start of construction. Printed: Monday, 13 August, 2018 1 of 2 • City of Atlantic Beach r.:*;17:"; PUBLIC UTILITIES DEPARTMENT -.i 1200 Sandpiper Lane Atlantic Beach, FL 32233 (904)247-5834 NEW WATER/ SEWER TAP REQUEST Date 7 - ZD- / $ Project Address 7 7 / Number of Units I Commercial Residential ✓ Multi-Family New Water Tap(s) & Meter(s) Meter Size(s) `f New Irrigation Meter Upgrade Existing Meter from to (size) New Reclaim Water Meter Size New Connection to City Sewer ` Applicant Name Applicant Address City State Zip Phone Cell Email Applicant Signature CITY STAFF USE ONLY Application It -0E75 1 8 - Q ZS-6 Water System Development Charge $ ( , I 01 06 Sewer System Development Charge $ , 00 5 U C t 5 - (-b Water Meter Only $ I B5, c5 6 Reclaim Meter Only $ Water Meter Tap $ Sewer Tap $ Cross Connection $ ,SQ , U(� Other $ TOTAL $ - (12-5—; DO (Notes) APPROVED Kayle Moore, P.E. Date 7 Z 3 1 \ Y Public Utilities Director or Authorized Signature ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED ?iyvyr City of Atlantic Beach _. APPLICATION NUMBER rjBuilding Department .,.,.• y;;,o,,,i; (To be assigned by the Building Department.) , 800 Seminole Road R E.-Sig -025o 5... �, Atlantic Beach, Florida 32233-5445 JUL 19 9913 Phone(904)247-5826 • Fax(904) 247-5845 l-:!,0109? E-malt: blding-dept@coab.us Date routed: 7 f r4 /1p O City web-site: http://www.coab.us N,, APPLICATION REVIEW AND TRACKING FORM Property Address: 771 .. rackse Lr\ De artment review required Yes No c r (( 1 Buildinq� Applicant: Jprt hqiecl B(kis ' nning & n ✓ Tree Administrator Project: J t i l c 1`7im( l .1--to ,e- Public Wor Public Utilities Public Safety Fire Services Review fee $ 9 d Dept Signature f°"‘- Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPyCATION STATUS Reviewing Department First Review: IVIApproved. ❑Denied. ['Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: �� �� Date: 7/2-3)1 V TREE ADMIN. Second Review: ❑Approved as revised. ['Denied. ['Not applicable PU= 'WORK Comments: e,...4-✓ 'UBLIC UTILITIES 7-Zo-i i PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ['Denied. nNot applicable Comments: Reviewed by: Date: Revised 05/19/2017 JS r j L`Jr r ,_,s, r CITY OF ATLANTIC BEACH ��r 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 \01319 (904)247-5800 ZONING REVI , f OMMENTS Date: 7/25/2018 Permit#: RES18-0250 Site Address: 771 PARADISE LN Review Status: DENIED RE#: 172376 0180 Applicant: Property Owner: SPRINGFIELD LBUILDERS LLC Email: Email: ralph.buck.davis@gmail.com Phone: Phone: THIS REVIEW IS ONE OF MULTIP i • ' • k NT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review.Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: Setbacks: Section 24-67(c) requires a site plan howing setbacks. Please provide a site plan sh• ing setbacks from all new elements to property lines. 7—7._c- /$ 7,_i;_s7: : 5 Mt& ccis.t Brian Broedell Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with "clouding".The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud.The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending,all sheets with revisions shall be inserted into each set of drawings.The original sheets must be clearly marked "VOID" but are to be left within the set of drawings. Complete new sets of drawings will not be accepted.ADDITIONAL ITEMS MAY BE REQUIRED DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW. i ir1,yr ECEIVFTh o,ifra:), JUL CITY OF ATLANTIC BEACH [I 6 2018 800 Seminole Road Atlantic Beach,Florida 32233 BY: REVISION REQUEST / CORRECTIONS TO PLAN REVIEW COMMENTS Date 1 I a--S 1( 4 Revision to Issued Permit Corrections to Comments V--Permit# K-C .i. 0 r WO Project Address -1-1 . sO ara dv- S QL - iv• Contractor/Contact Name Sp f\(\ .0 it &).-t.t Ulf--( S Phone Email ( AO . VIAL ; S 0 9,06 I`o 1/45il Description of Proposed Revision /Corrections: Permit Fee Due $ c IS çô NYL 't i) fl 444 4f\ m.o.. ,V5 Si A L 0041 w .1L+0kilr✓S C 3►A:A(& J 04-k . ha S iko c i`qp .4 ,( Lu`.L) Additional Increase in Building Value $ Additional S.F. By signing below,I affirm the Revision is inclusive of the proposed changes. (printed name) Signature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) V Approved Denied Not Applicable to Department Revision/Plan Review Comments Department Review Required: h---1.7"---- ui dingy' Plan ing &Zoningg j Reviewed By Tree Al i inistrator •u•lic I orks •u• is 1 I ities - �....../... 73ot e Public Safety 7 LG--/r Date Fire Services rif Earth Works, Inc. 12501 Beach Blvd Jacksonville,FL 32246 ,., Pine 16_ Pine l2' ;7\ 1 ` Disease1111d ,� ` 'r � -Pine 14' Oak 22' rl �� �. N 6" IP" WORKS EARTH ' Pine 14" GARDEN CENTER VACANT I is- - oak 12" I 'Li ` Lot 27 tip LUV A t . N T G ' O Paradise Preserve `u�e (L .:") 1 L O N II jAtlantic Beam,FL II 2 g X 0 1 Z B � � 1�'�1 J: nei6 1 2 6 w °e a" d _ ..-�.7. i- , seas� U we May 23.2017 N '" , Owning Scale: T=2a le l Oak 36" � \ y I O BY iaInc Revisions:f Al Pine 10" 1 ` t01lm -,�--. • `��' l�. On Site Water Storage is not Required 1 I ` 1.j 9 4 I in Paradise Preserve per Rick Carper I 1 ff I 1 Lot s£=5,6rea=. L i 1 _ L I [mpervicusatea=2584s.f. I I �----- �Pi LI_ ,1�1. ru7 • C.�!-EP.. 7 I 7.5'LA EA.S�,EMENT , ,. t, Imp E 1s0'"z_ !��', , 71/238. � S1 r� Sv 4 Sax 2- 1 -- P I MAW cups [ 41- ��Th ..: sir me FIB' �'� I --).\ Site —' PARAD/SE LANE ��_ ./.-____,..-...-../..-. "e" --WAY Plan !.:Inf., City of Atlantic Beach APPLICATION NUMBER a j Building Department s (To be assigned by the Building Department.) •- `-s 800 Seminole Road S 8 0250 ;�__, _. Atlantic Beach, Florida 32233-5445 Phone (904)24,7-5826 • Fax(904)247-5845 JUL 19 j 7//q /1S"'A�USiI!P E-mail: building-dept@coab.us A t -Date routed: City web site: http://www.coab.us •° ._ APPLICATION REVIEW AND TRACKING FORM Property Address: 7 7 I�Q roA Se Lr) Department review required Yes No , Build Applicant: pr i Irlj-c-i ei V`cL .S tannin &Zonin I Tree Administrator Project: J l ill e- 1"Q,1 r ( l ' 40NiePublic Worly5. Public Utilities Pubic Safety Fire Services Review fee $ Dept Signature . Review or Receipt Date Other Agency Review or Permit Required of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants . Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. riDenied. ❑Not applicable (Circle one.) Comments: BUILDING n PLANNING &ZONING Reviewed by: Date: /i;yie TREE ADMIN. Second Review: Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: ' Date: f;-/.p FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 's r CITY OF ATLANTIC BEACH \ ... sJ Department of Public Works r s� 1200 Sandpiper Lane Atlantic Beach, FL 32233 J;31�f' (904) 247-5834 PUBLIC WORKS PLAN REVIEW COMMENTS Date: 7/24/18 Applicant: Springfield Builders, LLC Permit If: RES18-0250 Email: ralph.buck.davis@gmail.com Review Status: DENIED Site Address: 771 Paradise Lane THIS PLAN REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS Correction Items must be submitted to the Building Department at 800 Seminole Road. Submittals that respond to only one or a few correction items will not be accepted. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions must be submitted to the Building Department and must respond to EACH department review. PUBLIC WORKS CORRECTION ITEMS: • Must submit a Floor Plan. / 19: • Must submit a Construction Site Management plan. l � Scott Williams, Public Works Director swilliams@coab.us / 904-247-5834 Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with "clouding". The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud. The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with revisions shall be inserted into each set of drawings. The original sheets must be clearly marked "VOID" but are to be left within the set of drawings. Complete new sets of drawings will not be accepted. ADDITIONAL ITEMS MAY BE REQUIRED DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW. Page 1 of 1 0:\Public Works\ADMIN\PLAN REVIEW COMMENTS\RES18-0250(Springfield Builders).docx j:ri J* CITY OF ATLANTIC BEACH a 800 Seminole Road 1-'):141 . t A(f L ) €U13 Li Atlantic Beach,Florida 32233 REVISION REQUEST / CORRECTIONS TO PLAN REVIEW COMMENTS Date 8.,1 / Revision to Issued Permit Corrections to Comments Permit# RL 51 p -0250 Project Address -7'7 I Kara 4� Co_,,,,_ � I �� Contractor/Contact Name 5C�:,. l T` c k� IK,_:l N. L �,..)-c_1 `Jcx.A- Phone LIK:31 ' Gid a 07 Li Email i(,.`,QL. �a . akaJ►ss C c\fr( \ .c „,., Description of Proposed Revision/Corrections: Permit Fee Due $ IA-Mr Additional Increase in Building Value $ '` Additional S.F. By signing Belo \(\ u \��,-v:s affirm the Revision is inclusive of the proposed changes. ,.rinted na e) G - 2- - /e) Signature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review Comments N. Department Review Required: Planning &Zoning 'eviewe i B Tree Administrator lic Works;�� "4.;2..//,52 Public Utilities Public Safety Date Fire Services CITY OF ATLANTIC BEACH (--- '`t JUL 16 0180 800 Seminole Road si r� 2 Atlantic Beach,Florida 32233 BY: REVISION REQUEST / CORRECTIONS TO PLAN REVIEW COMMENTS Date 1 I a--..S i(C Revision to Issued Permit Corrections to Comments Permit# K--C. Sl ^ Ns-c, Project Address k c( 1 'Y cc�ls p-- L-(1• Contractor/Contact Name Sp I11" ci L!d tot 1 1 S Phone Email ( ct1.* \ - bat,i- - Attu , S @ilyvi.(1 -(eti Description of Proposed Revision /Corrections: Permit Fee Due $ c tSPonM- ID a :ir: ebm .-a}. — skAL a-(1 & 1 sseroaL.-S C a,x(q i f\ontrhu \ A0 k- C MP - d sf to`,1_,.)) Pw Cor�� ,i on CohnvtnQ,y�}� cL-ko ed Additional Increase in Building Value$ Additional S.F. By signing below,I affirm the Revision is inclusive of the proposed changes. (printed name) Signature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved 7 Denied Not Applicable to Department Revision/Plan Review Comments w Department Review Required: uiging % � Plan ing &Zoningj) Reviewe Tree Ad i inistrator •u.Iic I orks •u. is 1 I ities 7/LIPAP Public Safety Date Fire Services . " / 4 Earth Works, Inc. 12501 Beach Blvd Jacksonville,FL 32246 Pine 16° Pine I 11( i ` 1 Fl ___..... ,-- , fj�` =Pine 14" Oak 22' sem► /` � \ _� - 4Pine 14" OR � IImo \_I VACANT 1:"" N 12 I 1 un1: J'.. �?C PandaPreserve r.,�� m V A '_ Paradise Lane 0 2 7 N Atlantic Beach.FL I' 1111111% ---4 r /='ne 16' 6 \ 29 SOT 28 _._��1 tiro: , L ° T 2 W Oo8" Q Date May23.2017 I . /a I to Drawing r=2v'lI(Sitl na Oak 36" )/ 141114/1> �' \ By:Fas+wk.. ` :/ Pine 10" ii !Diseased - \' \1 r I fid° + • II On Site water Storage is not Required I •.. � _ : .1.9 4 I in Paradise Preserve Pc Rids carpet I Lot s.E=5,620 sf. L F -,_I__ Impervious area=2504S.f. P ' 100091110. .r4-EP_. 7.5'LA EASEMENT , iPtoga i X6.. i , :- _ a TIT /83 Sv - '2 OP-1.0;2 �/ MAW cue i-r� PARADISE LAIC Y �'`� Site Mama ` Plan CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD \ � ATLANTIC BEACH, FL 32233 �Ji31�f (904)247-5800 ZONING REVI - ' OMMENTS Date: 7/25/2018 Permit#: RES18-0250 Site Address: 771 PARADISE LN Review Status: DENIED RE#: 172376 0180 Applicant: Property Owner: SPRINGFIELD LBUILDERS LLC Email: Email: ralph.buck.davis@gmail.com \,..Phone: Phone: THIS REVIEW IS ONE OF MULTIP i • . k NT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review.Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: Setbacks: Section 24-67(c) requires a site plan howing setbacks. Please provide a site plan shing setbacks from all new elements to property lines. Brian Broedell Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with "clouding".The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud.The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending,all sheets with revisions shall be inserted into each set of drawings.The original sheets must be clearly marked "VOID" but are to be left within the set of drawings. Complete new sets of drawings will not be accepted.ADDITIONAL ITEMS MAY BE REQUIRED DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW. i-i.\i'j '1 41,11: , t( '---- CITY OF ATLANTIC BEACH :k!' 800 Seminole Road r 15 _ .. �r Atlantic Beach,Florida 32233 &J;3!9' REVISION REQUEST / CORRECTIONS TO PLAN REVIEW COMMENTS Date 'T I a-� 1041 Revision to Issued Permit Corrections to Comments Permit# K-C— Si " 01f) Project Address `-1t. sp a(aO-t\S L Li\• Contractor/Contact Name Si)f\n L A d Li:i d0-f S PhoneEmail ( �l O • bac, Attu , S P rats I`(64-1 V Description of Proposed Revision/Corrections: Permit Fee Due$ c LS Pb ' II) 4-1 .rir: r(\ -A,k5 SAL Oat') w <CuttO 6itt,S C__. &,CAtti. f. 1)Q_Rk . VNGt_S iik 0 k- ib r"APOL-ite_461 0.-k;,tf-J) Additional Increase in Building Value $ Additional S.F. By signing below,I affirm the Revision is inclusive of the proposed changes. (printed name) Signature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved / Denied Not Applicable to Department Revision/Plan Review Comments Department Review Required: ui ding si' .611.' A► Planning &Zoning—2) Reviewed By Tree Ad inistrator •u.lic I irks 7_2 5 ' (— •u• lc I i sties Public Safety Date Fire Services s 'rj,,-L�l l J �'� CITY OF ATLANTIC BEACH i-' r) r. 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 c r \ ;3» (904)247-5800 ZONING REVI - ' OMMENTS Date: 7/25/2018 Permit#: RES18-0250 Site Address: 771 PARADISE LN Review Status: DENIED RE#: 172376 0180 Applicant: Property Owner: SPRINGFIELD LBUILDERS LLC Email: Email: ralph.buck.davis@gmail.com \Phone: Phone: THIS REVIEW IS ONE OF MULTIP NT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: Setbacks: Section 24-67(c) requires a site plan howing setbacks. Please provide a site plan sh. ing setbacks from all new elements to property lines. (zc✓sem.-, : 5, A4..cA Brian Broedell Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with "clouding".The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud.The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending,all sheets with revisions shall be inserted into each set of drawings.The original sheets must be clearly marked "VOID" but are to be left within the set of drawings. Complete new sets of drawings will not be accepted.ADDITIONAL ITEMS MAY BE REQUIRED DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW. sig,a,y City of Atlantic Beach APPLICATION NUMBER itta Building Department (To be assigned by the Building Department.) lr 800 Seminole Road R E S I O -0250 _r Atlantic Beach, Florida 32233-5445 Phone (904)247-5826 • Fax(904) 247-5845 / / ��I31y: E-mail: building-dept@coab.us Date routed: '7//� ` 1 S City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 7 71 FPO_ ro_�Se Lt-1 De artment review required Yes No � ` r Building) Applicant: 5 r L n 1i,� B( lannin &Zonin Tree Administrator Project: J n i e- PQM( ( Uae Public Wor Public Utilities Pu lic Safety Fire Services Review fee $ Dept Signature Review or Receipt Date Other Agency Review or Permit Required of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: I /Approved. ❑Not applicable (Circle one.) Comments: weed )7t6enied. l L/ BUILDING $:+e /ad) /A-A �e 7(1jG��i<f PLANNING &ZONINGReviewed by: / � Date: 7 2 $ I l� TREE ADMIN. Second Review: Approved as revised. I (Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: 7'2 I FIRE SERVICES Third Review: ❑Approved as revised. DDenied. nNot applicable Comments: Reviewed by: Date: Revised 05/19/2017 t I .4 rj"`�'JrJ Vit*. TREE REMOVAL CALC LATIONS J l City of Atlantic Beac 1,17) ctg Community Development Dep, tment 800 Seminole Road Atlantic Beach, Flori!;a 32233-5445 jlaSc}!. Phone: (904) 247-5826 Fax: (904) 247-5845 Emai'. Building-Dept@coab.us 41 0 Permit: TREE17-0026 Applicant: Springfield Builders,LLC CO1PNI 6 Address: 13846 Atlantic Blvd#204,1] 1, ••:R lie perm.. sk Site Address: 771 Paradise Lane Phone: 404-626-0245 V pprovea 8p pactU' t RE#: 172376-0180 Email: ralph.buck.davis@gmail.co guild~n9 e• e h( 'l?`{ Cigif\trik TREE REMOVAL CALCULATIONS j REMOVED Legacy(non-oak) Legacy(oak) Oaks Pal Is Others Total Protected Trees Removed: 0 0 32 0 45 77 Mitigation Needed: 0 0 16 01 22.5 38.5 , Trees Removed: 2-6",8", 12"Oaks; 10", 11",2-12"Pines t MITIGATION Legacy(non-oak) Legacy(oak) Oaks Pali s Others Total Credit for Trees Preserved: 0 0 0 0 0 0 I Credit for Trees Relocated: 0 0 0 0: 0 0 Credit for Trees Planted: 0 16 0 2,; 0 40 Total: 0 16 0 2,1 0 40 T 1 v Trees Preserved: None for credit. Trees Relocated: None for credit. Trees Planted: 2-4"Live Oaks;3-8"Sabal Palms 1 *Planted Legacy Tree species receive DOUBLE credit when replacing non-Legacy Trees.Th i Legacy Tree list includes Bald Cypress; Southern and Eastern Red Cedars; Winged and Florida Elms; Live and Sand Liv Oaks; Hickory; Pecan; Pignut Hickory;Loblolly Bay; Southern and Sweetbay Magnolias;Red and Florida Maples; and Tu i elo. i ADDITIONAL MITIGATION REQUIRED (Mitigation Needed--Toi.l) Legacy(non-oak) Legacy(oak) Oaks Pal s Others Total New Trees Planted: 0 0 0 0I 0 0 or Payment Into Tree Fund**: $0.00 $0.00 $0.00 $0. 0 $0.00 $0.00 or A Combination of the Above** **At least 50, o of mitigation must be onsite. i Additional Notes: Mitigation is 1 inch preserved or planted for every 2 inches removed. Tres;Fund rate is $116.00 per inch. Also preserving 14", 2-12" Palms; 16", 24" Pine; 8", 14", 22" Oaks; 6" Sweetgum. Also prese ing 14", 2-16" Pines; 12" Oak; 6" Sweetgum. 36" Oak fell over in Hurricane Irma, no mitigation required. Paid $377.00 for 3 ►5 inches of outstanding mitigation. i. Recipt:R2713.Check 612. Status is in accordance with the City of Atlantic Beach code of ordinances in effect at the time if application submittal. I APPROVED DENIED 0 j -00"........4--6,--, c% .----1 /x/17 TPO ADMINISTRA i,•R DATE i Earth Works, Inc. 12501 Beach Blvd Pine t6_ Jacksonville.FL 32246 D seaud C ri 4APme 14��` (E�f/A�R�T�[H� V. [,. *0014" WORKS GARDEN CENTER _ „ GI � VACANT Oak 12" it LI 1t'' m V A\``A N T 1:.h /0,3 r LaiP Preserve Shin ` o Paredrae Lane --7_,----a..---,- N Mantle Beach.FL —NAV ! Vs."-. t 9 7 \� , Pine 16" Z ( / G 7 2 6 ,4 X1,1,0! oak 8. 1 di 4 a �e ;I '�' N May 23,2017 ��., praying setae. 1"=20' (KSR) Oak 36" % ZA. ,1 Designed By:Earthworks me 14141k7;'--k �tl Pine10" Rerawrc1 , _ .r.iil Diseased ~. \;. ,, •9 On Site Water Sti ge is not Required in Paradise Presage per Rick Carper 1 1 Lot s.E=5420 s-f. L _ impervious lea=2.584 s.f. i'�('— r_ _--75'JEA-EASEMENT_ 75'.EA EAMIENT Pine 1" :;1 �7__lOxo1�T .sen.1 'al . ttM�g�'''„'""�- 12" Fja.1704 ----- �� ��- p \ � - CFO rmr LAME K eRIGHT-or ANY � �` Site Plan J i Earth Works, Inc. Sit T FENCc I 12501 Beach Blvd Ca,Ia a 996919-616.. Jacksonville,FL 32246 Wine 16" —n,a.m:_,aa m;,ax—aa,,;.�,- s• t:a�,...c s,s a acs Pine 12" T_ tc...t.4,a m�•x.x.ee x cot t.. a - Diseased -;:z_.3 m=.e:.v r p.r a.xhv ca \ " a.a em cm gat ta o..a a` aca... il_� 1 ::cu,sa to aa:ate=c-nm a.avx c u m I, /������ as_,m __e a'..a".,.-::a:_ c.ca.... a l �((�1\ 4, � Pine l4" a.m. a a Ra•_�..:._ ::a c�—`_j:,a.Ica; rl Oak 22 Styee• 6' ▪ c tat rat s_ a ;hai..a to a z a u: ��y■ • ' rs.f. s.t. s.f. s.E s.f. >:.,s:.m`.-7";--(7:V.,?,=,'•-!'gr.,-It'V MT ■ I Q:racta-ao-::a�.aw / r_ca.tact to at..ce a c, t j \/ Drainage �-._�,-�sa kat..-.�y,ra i„Y...mx L, g Pine 14” •a::a I,c laae 'Law.ts '?.Vt. FW,--Aiiimbk—N Flow �:w ar,a L� afr-;i"-,e.M ra, G1 � �N�ER `_ Iran a...�+ zac.r,cacna_ • I rmaa,,aamaox�al_e_a Irl\ . &',nzd W ua m x-nom-,=a e- `gym Nb Ma t�+Ca cl=R a-e; a Ira, • 669 61 aty=l tc-1 c:Y:x ln'..- rot Da at 1rt le s�P VACANT i���� oaktr` _ �dw: :r��`n a.'� ' ''+ N �_' Su. pt 4a 4i,.>"_t act:.cr fatty 0 �I O j i,'(�I ^I I tat.:til.tact..Mea cal :-]_:t_cat CV maaua Eta Lot 27 it P ,l ®V A A N r �,atn r.ea:aa r a ea. ca.a r. Paradise Preserve 1 _ JY 4a~t CN� � s1. as am rl O�� ri L Q 2 ] en s.-...,-..., :-n_ha,arc.u_ Paradise Lane i I' a arra=a t tears n- _ar.Traa ec::a, Atlantic Beach,FL _1I _ 74.;47 a :4,.Y_�y r3vm:s•-....1>a Q t Pine 16" .L 6 n 4. ra,.,,sus rG.m 6-69 v T 2 9 1�' . ." �1' oaks• L p T an..�, �:s nir>a:ia �f aaa sii6. a haaa4rt 6 6 6. a9 L 0 ��:` 6 _ =a/ya a:a: ears Date: May 23,2017 3 t---� l7awin9 Stale: 1"=20' Ifc$h') `'�- ^I vein, '- aa-.• ra Designed By:Earthworks Inc iak36" ? �� ., � ���-r:a:rns"."as.� _ Revision, On Site Water Storage is not Required '• in Paradise Preserve per Rick Carper _ '4' a ss J'- Pine 10" ��c� s,. r' Diseased 11, Lots.f=3,620s.0 �� `�1 ,r' ( �,: R, JrE� Impervious area=2,584 s.f. V�--'-------••1-111.--7 _� ;'g' Drainage Flow _,,,� +(' --��r_ _aline 11 -.;t 1_ °R--P-5-- + I Vgr.s}-a l !1 1 7.5 IA EASEMENT a.sra.-, • i. i70 EA 6.69 �I TiWki?r' _ _'`a 1111..1....- Oak 12"• ,—i Ill cuR8 own ' :;,,,� pAlP,ayF fi �� s.:sen a. o srg1 al.C._ (art&rET � ""`�`�" � Erosion & RicH7 — war ., enee inErg Per H.O.A. - Sediment Jir.. C6-$014 �, .a :l�gy"m :n c6roviinriaii s.sii secs c_�.a.m%ona mac.. i::. .-.,PICS J WM Earth Works, Inc. 12501 Beach Blvd Jacksonville,FL 32246 —�*Pine l6_ 7 Pine—17—' ` Diseased °al'22.I \ s.f. ' •- EARTH . s f. s.f. s.f. 6" \ Drainage Pine 14" GARDEN I Flow s•.� — �I VACANT oak 12" =� l ■r Lot 27 o J1n IVA `ANT ca I mo`Preserve .II L 0 • 2 _� Atlanae Beach,FL aradise Lane I-- U i ` J L0T 29 U T 2 $ i.10, "\�� �?I►i� Oaka" \`( Pine`6' T 26to L 0 • a e` f = May 23, ` I F owe, sok: 23,2 2017(KStt) Designed Br On Site Water Stow is not l �� �'� in Paradise Preserve per Rick Oak 36• '�_` `' Y '� X006: lei- .,' �_ Pine 10" ��>i,•f.. Diseased Lots.£=5,620s.f. \ I1 - 1 ���Impervious area=2,584 s.f. \```_Chemical Toile ��'�' `_ Hyl. j� 7, off _ A CT!' ► f —t'1 •�,!-I sensed I �.`7 (rw-�yty,, �,1_c "'' �Ia,1,S . ,T� -��a(, 1. tom " 7E8 sw _ ' 5`� Oak 12 2 ° -•'m' 'Si-F.031, i7a�� 1oAy�CURB .; 1 SHEET . PARALyg LAAII y in —_ . Construction �'A '�• �+T—Qr—�,Y Management \._ 1 Earth Works, Inc. 12501 Beach Blvd Jacksonville,FL 32246 •-,e 16" i _ — — ;� - 4P.s � 4-Live oak 1) �`H Straw Jk� Pine 14' WORKS Oat Tom' . ,6" 7 ..es • I ,-- GARDEN CENTER e I , �. i `rte it 'nel4" -21 / VACANT I I ^^ _ �On�"4 \ /c 3g Splideaf Philodendron(4) I -.1 I -- - -- -- '--f 38 Walters ViLisnum(7) Lot 27 ■a'N Paradise Preserve s Paradise lane \ 3g Podocatpus(22) I 'r• ® y. N T \ Atlantic Beath,FL J .a ®18 Fri J ` / N io I. SLOT 27 fl! 1 �j I1 1 1 1 _ May 23,2017 L 0 T 2 9 _ll o T 2 8 I ' - [ I�co; 1 1. o i 4 6 rbaer Earthworks Inc KSK) 1;.i I „is�—a F J •r1 4 Revisions ( IU iIq # � 3s1h e tIR3g Podocarpus 6) l'14.'f:s v 8"Sabal Palm(3) lie-l.e. '' - L 1 Ig Boxwood O. l(I8) O d!•4611?' 4'Live Oak(I) �l11 ''��, ± { __- t "�'JC�: g Afiican his°0) Illi3g Muhl),Grass(18 x )'1 I sod i :"i'it,:% - -K_ 3g Muhly 3rass(13) I�?5,-,EA- a '� a=�u r 5 EASEMENT `- 1 Kfl ;:� I 1 1p' �2as i� _ --,i I p W 7 SV ` S i �CB sod ; - ,Oak 12" [ LandscaPe F 1i� 1 \ .. Plan PgRq�y i ANf V1R/( ! 187 sf. LE Tom`MAY —-- • —Ig Asiatic Jasmine(50) —Required Fence - Per FLO.A. • i Earth Works, Inc. 12501 Beach Blvd Pine 16" Jacksonville,FL 32246 i Pine 12' ; -.� Diseased 4"Live Oak(1) / ,4, (Legacy Double Inch Credit) Oak 22" .rL4p 'inc 14" rVI ,... Sw•\, .6" EARTH WORKS - \ - li*Pinc 14" GARDEN CENTER N AI — 41 _.-- VACANT r •! Oak 1-2" b �' 1 EN %1"` j„V A C A N T ° ParadisePreservePreserve Paradise Lane r ,II Atlantic 27� .__:°- T 2 9 Q '.' _ 1111)11% 1 ne 16- 0 ° LOT 2 B i- \ 1[I�II Dads" L" T 2 6 „'• � 11 x \ :' !.. / �, (ffic May 23.2017 OrMi�psde: r=m 111 _...4 I designed 9r-Eanhvunn Inc X Tree Removed i Oak 36" )r:Ccifittl.X. C 0 Tree Preserved �,i Pine10" 2 -1A#_a;-::- Diseased 0 Tree Planted � - - L ' X " i' i j' QTreeRemoved 1� \6 Pin- ?1�'"r- s"salmiPalm(3) No Mitigation I sy]. ,a• 4"live Oak(1) ' .:., _.'_, (Legacy Double inch Credit) i t _ I a-I-, AD / f � ^ YF- 1.5'.EA EAfr Ppii 1/ o \ J FLB•1712. aAP@ n."---------------------1 - te i Tree ''B'E� +T" WAY CeenrerrE Inventory Tree Mitigation Tree inches removed: 100" Tree Mitigation inches required: 50" - - Tree inches credit 6" Tree inches planted: 46" Mitigation payment required 4"@$116/inch $464.00 NM r>,:ir1A1�t,- Cash Register Receipt Receipt Number City of Atlantic Beach R2355 BJH>r DESCRIPTION ACCOUNT I aTY I PAID PermitTRAK $250.00 TREE17-0025 Address: 761 PARADISE LN APN: 172376 0185 $125.00 TREE REMOVAL $125.00 TREE REMOVAL RESIDENTIAL APP FEE 1 00100003291005 I 0 I $125.00 TREE17-0026 Address: 771 PARADISE LN APN: 172376 0180 $125.00 TREE REMOVAL $125.00 TREE REMOVAL RESIDENTIAL APP FEE 00100003291005 0 $125.00 TOTAL FEES PAID BY RECEIPT: R2355 $250.00 C IL -- -1--- csq / _ Date Paid: Wednesday, August 23, 201 Paid By: SPRINGFIELD BUILDERS LLC Cashier: BA Pay Method: CHECK 589 \., 11-s Pn ed:Wednesday,August 23,2017 10:48 AM 1 of 1 1 C1J.v.;y�, City of Atlantic Beach APPLICATION NUMBER • " c1 Building Department (To be assigned by the Building Department.) -•-• 800 Seminole Road R ES IS p 0250 Atlantic Beach, Florida 32233-5445 O Phone(904)247-5826 • Fax(904) 247-5845 fi E-mail: building-deptcoab.us Date routed: 7 fq O City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 7 71 'Pa.. ro((ce Ln Department review required Yes No (� ( 1 BuildinApplicant: r ( n3ce1A BtOLvs tannin &{ Tree Administrator Project: J l r(�I e— 1 ttv .( ( '" ' 'late Public Wor J Public Utilities Public Safety Fire Services Review fee $ Dept Signature oRPermit Verifiedeview or pt By Other Agency Review or Permit Required Date Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. KDenied. ❑Not applicable (Circle one.) Comments: BUILDING (y PLANNING &ZONING Reviewed by: Date: �-7^/d /r, TREE ADMIN. Second Review: [Approved as revised. ❑Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES -7 PUBLIC SAFETY Reviewed by: ill�/y�t' Date: (F ' /-13 FIRE SERVICES Third Review: (Approved as revised. Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 3 CITY OF ATLANTIC BEACH 800 Seminole Road Atlantic Beach,Florida 32233 REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date I<)-,j i( Revision to Issued Permit Corrections to Comments VVv-Permit# K-( �� 0 r Oa-50 Project Address ' I Pala d.A Contractor/Contact Name Si)f'I cl L�4. f)t� t Ulm Phone Email 1 CAQ‘1 . VIAL k S •01 Description of Proposed Revision/Corrections: Permit Fee Due 519.0,0 c Q�s p Nsk ID c41 T,,:r: tOrn -A} S _ sA L �Q/, w 1 .1-tic) Lt- S g a-A d f\ p 4\ I\u_s AO k- cb-pie L/.:w' Additional Increase in Building Value$ Additional S.F. By signing below,I affirm the Revision is inclusive of the proposed changes. (printed name) Signature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review Comments Department Review Required: uircling Planrfing &Zoning2) V Reviewed By Tree Ad inistrator •u•lic v orks p, •u• is 1 i ities O 7 /kr Public Safety Date Fire Services 1 • \Sf CITY OF ATLANTIC BEACH '� 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 " o;317.5 - ..7 �%' (904)247-5800 ZONING REVI , , OMMENTS Date: 7/25/2018 Permit#: RES18-0250 Site Address: 771 PARADISE LN Review Status: DENIED RE#: 172376 0180 Applicant: Property Owner: SPRINGFIELD LBUILDERS LLC Email: Email: ralph.buck.davis@gmail.com Phone: Phone: THIS REVIEW IS ONE OF MULTIP • . ' . k A NT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: Setbacks: Section 24-67(c) requires a site plan howing setbacks. Please provide a site plan sh• ing setbacks from all new elements to property lines. ZG 4.51 it 5 c-e- A-44.cLc Brian Broedell Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with"clouding".The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud.The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with revisions shall be inserted into each set of drawings.The original sheets must be clearly marked "VOID" but are to be left within the set of drawings. Complete new sets of drawings will not be accepted.ADDITIONAL ITEMS MAY BE REQUIRED DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW. ftvy rfJ,� �i s, OFFICE COPY CITY OF ATLANTIC BEACH 800 Seminole Road 3.17 imp) _.,yAtlantic Beach,Florida 32233 REVISION REQUEST / CORRECTIONS TO PLAN REVIEW COMMENTS Date �'� Revision to Issued Permit Corrections to Comments_\Permit# /`E` t C)ZS L Project Address -17 ‘ �....►ac�;r,_ &-. L Contractor/Contact Name i--, c Phone Ll—10.1-4 _ 014 C Email ( (5_AfL : \-- 1/4,..-J<._ X<�_ ., '\ ev--. '1 . 0;..1 Description of Proposed Revision/Corrections: Permit Fee Due $ a&LA CFE re. 1t.1 T,,,‘.4 k 1 '..k a Additional I. •ase in Buildin: : • f'. Additional S.F. — By signi :bel• ��# �s-4-- 'L � ,� a,`;s affirm the Revision is inclusive of the proposed changes. (printed n. e) Signature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved )(--- Denied Not Applicable to Department Revision/Plan Review Comments Department Review Required: Buildipg /711)_. Panning�Zoning Reviewed By Tree Administrator Public Works Public Utilities ---7- p'/ 0 Public Safety Date Fire Services CV * 'A CITY OF ATLANTIC BEACH t;t A l' 800 Seminole Road -.� Atlantic Beach,Florida 32233 r REVISION REQUEST / CORRECTIONS TO PLAN REVIEW COMMENTS Date &-1—/ Revision to Issued Permit Corrections to Comments Permit#12&S/& U0? ,SC) Project Address �1 ( k `=s`''C C'- - 1,"L. Contractor/Contact Name Ser.:�G , cc1-<,..A s L� . "H � a,vt S lt � Phone `i _ (.;?_40` tsZ�-{S Email ffi�\.e\-_. 6.kit_. &o v C or`\ ,e ten, Description of Proposed Revision/Corrections: Permit Fee Due$ C:, 1, A-tue z3 Additional Increase in BuildingValue$ Additional S.F. By signing belo ( �-\,f\; J�- r----Oe,-v.', affirm the Revision is inclusive of the proposed changes. tk ,.rinted na i e) Signature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied 24 Not Applicable to Department Revision/Plan Review Comments /77, S i h /=', FT E Department Review Required: yuildin 7-1A)/"" Planning &Zoning Reviewed By Tree Administrator _NINE Wor<s (� Public Utilities d — 7 ad Public Safety Date Fire Services 11 - \@CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD !J = ATLANTIC BEACH, FL 32233 (904) 247-5800 .J-./ J ii l_r_ BUILDING REVIEW COMMENTS Date: 8/7/2018 Permit#: RES18-0250 Site Address: 771 PARADISE LN Review Status: RE#: 172376 0180 Applicant: denied Property Owner: SPRINGFIELD LBUILDERS LLC Email: Email: ralph.buck.davis@gmail.com Phone: Phone: THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: -_ I . Contractor shall write on 2 copies of the site plan the minimum Finish Floor Elevation, initial, and date. I will attach a file that will help in assigning the required elevation height for the City of Atlantic Beach. - - n Building C'• t�' ' 7'/ Mike Jones 111K Building Inspector/Plans Examiner City of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233 904.247.5844 Email:mjones@coab.us Resubmittal Notes: Er"-el i/-eC/ iZev I'e L✓ Cor Mn 4'4:fr F-7• / S fv‘sY All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with "clouding".The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud.The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with revisions shall be inserted into each set of drawings.The original sheets must be clearly marked "VOID" but are to be left within the set of drawings. Complete new sets of drawings will not be accepted.ADDITIONAL ITEMS MAY BE REQUIRED DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW. '/ / t . f t A. Earth Works, Inc. 12501 Beach Blvd Jacksonville,FL 32246 /P� 16 ;tea- \ 1 11 nevi- Oak 22' Ni _ ,,,, 6" i/ / EARTH - 4Ptoc WORKS 14• GARDEN�Nf i. I VACANT "`�' oat 12" ` I / ° V c ta.ar rraara.A u;I; V L O - 2 7 t N Mantic Beach Ft _ r J Il \ J Paradise Lane • �j 1illliIV r ••eel6• 6 29 LOT • 26 - iii ��It'►'s o08» LCT Z CtiQ U Cale May 23.2017 V) 0.01109 SOIC 1" ipak36" c74A..'-' li -Illir...-ri \ \ I Deigned BF EaN.=20'arke Inc( ! � � 1 ' e4 7A* �j Discard 1 t ` C 1' l� _ t 9 T site water Storage'sg �� II ,, — I in Pecadise Preserve Per >� IImmplrvviau area a 2,584 s.£ I /� /�_Z 4 Pte_FJfL_.� --73,77------, I 7.5' r t__. o tPo FJIs". /Cg Sv i , l o (E L-- 's'' � rt , V Site -s,> Plan :1 /i�" Building Permit Application Updated 12/8/17 ri )FF ICE Ci City of Atlantic Beach z_;t 9''' 800 Seminole Road,Atlantic Beach,FL 32233 Phone:n (904)247-5826 Fax:(904)247-5845 8'... O� Job Address: 77 1 ) ars-Ai 54_ K ,.t , i"(a..-k_ f c,d3/-2-3'Permit Number:RES 625° Legal Description 1.,=;,-(-- Z7 f? csrc_C ' 7lej.nrLS . 4dtV:�,6,1 RE# /72-37/, -E)(3' Valuation of Work(Replacement Cost)$ 2-5-3, roc' Heated/Cooled SF 2177 Non-Heated/Cooled 5-67 • Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): Commercial(esidential • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No (N--/---A-\ • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: + 1 CJ'v5�rJ.0 ") - x�c\ lieu-) S t..Ael L c� -- m � .\A O\ �tt t Florida Product Approval# for multiple products use product approval form Property Owner Information rrA Name: ie r"":el � -t`�Q,5 i LL. 0 i3 Address: '(0 At\6 ,e_��J• - �y Z City °-� r" k��c\ ,r,c. -..AIL State Cl Zip 32-Z7.c Phone qEY e„?-4. UZ`tS E-Mail F.A,,,1n..bcx.c , ok0,u;5 6\ Com,,(, c c or Agent(If Agent,Power of Attorney or Agency Letter Required) Contractor Information Name of Company: S&rt d., raw mac,— Qualifying Agent: 1�..a\-(�T+A,�L I)t�/tS Address City State Zip Office Phone Job Site/Contact Number State Certification/Registration# (._: -- e I t5e(29 E-Mailrr Architect Name&Phone# c.1__ r.�.c cs�,ct.--% '7 - 71 D ` gO L Engineer's Name&Phone# �4�s bk.ri +,N er. "1 9-4 " 86,- 2-9.0 / Workers Compensation ` Exempt Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do t e work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT ' OUR PAYING TWICE FOR IMPROVEMENTS TO OUR PROPERTY. •U INTEND TO OBtAI FINAN . , 'ONSULT WITH YOUR LENDER a R ' N ATTOR BEFORE RE RD Y'0 ' NO )ICE OF COMMENCEMENT. I L/ _ (Signature of Owner or Agent) (Signature of Contractor) (inclu ing"contractor) S' ned nd sworn to(or affi m befo e, t rl ay of Igne and sworn to(or affirm• 'before e t I r_ •ay of t �L ,7C� ( �by � ►=� ��4VcS i`7� ,O(P, by Io � ' , C 1 lir �--- .,,,...„a( nature of Notary) (Signature olf Notary) TNI GINDLESPE •..,ws•.r,�- ersonally Known OR '':, • «- MY COMMISSION#FF 924951 [Personally Known OR 3 _, :r °° a•�=; TONIGINDLESPERGER [ ]Produced Identification *p EXPIRES:October 6,2019 [ ]Produced Identification` f `.t MYCOMMISSION#FF924951 Type of Identification: °`°` Bonded Thru Notary Public Underwriters Type of Identification: EXPIRES:October 6.Pnta Thru Notary Public Underwriters OFFICE COP'\ PERMITTED BUILDING DATA DO NOT WRITE BELOW - OFFICE USE ONLY Applicable Codes: 6th Edition (2017) Florida Building Code DEVELOPMENT SIZE: Habitable Space (ft') 777 Non-Habitable Space (ft') 75 Cc, LAND INFORMATION: Zoning District P V Flood Zone X Minimum FFE BUILDING INFORMATION: Construction Type V ti(17 Occupancy Group 5-,05 17- 0 (r Number of Stories 2 Max Occupancy Load Fire Sprinklers Required /Ilk CONDITIONS/ COMMENTS: Ai n vd / C A n c -e- /7-'(oo d a Fo -- Rev. 2.7.2018 Duval Map 1;iii► 0.2 PL1 ANNU..LCt IANLL I LOUD ItAZARU Yaf. yet avail+ x w u x•++rv+w+.i . vsa reTu r.r n..F wv: 761 17231910180 0408 H 7'11 781 p ; 44, Pea pdaalid' : aana Nfap data yet 0 "__ talalt a8al 4 yet avail n August 7, 2018 1:282 0 0.00225 0.0045 0.009 mi i 5 5 I) L, I I 0 0.00375 0.0075 0.015 km Sources:Esri,HERE,Gamiin,Intermap,increment P Corp.,GEBCO,USGS, FAO,NPS,NRCAN,GeoBase,IGN,Kadaster NL,Ordnance Survey,Esri PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA $--- Permit # ��Sl 4 a Cc)Name: w��r� 1L s, ���— L Project Address: 1 _i\ Lo, As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact product approval may be obtained at: www.floridabuilding.o Category/Subcategory Manufacturer Product Description 1 Limitation of Use State# Local# A. EXTERIOR DOORS I — 1. Swinging F! q3.34 2. Sliding 3. Sectional II 4.Roll up CN-i Dver-U‘c"ct f1-/S1Y7 5.Automatic 6. Other B. WINDOWS 1. Single hung t,� Is.,� i I-i LI Q I I .1 2. Horizontal slider 3. Casement 4. Double hung 5. Fixed J ;ric- 6. Awning 7. Pass-through .._8. Projected 9. Mullion 10. Wind breaker 11. Dual action 12. Other Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# C. PANEL WALL F/ - /37L9 1. Siding r 2. Soffits � 3.EIFS 4. Storefronts 5. Curtain walls 6��a11 JQuyers_ 7. Glass block 8.Membrane 9. Greenhouse 10. Synthetic stucco , 11. Other D.ROOFING PRODUCTS 1. Asphalt shingles ©U't-A5 F,06 7 y.I 2.Underlayments Gt p"��, 3c /, . �I�-- F/-12_322,1 3.Roofing fasteners 4.Nonstructural metal roof 5. Built-up roofing 6. Modified bitumen 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation 10. Waterproofing 11. Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coats 15. Roof tile adhesive 16. Spray applied polyurethane roof 17. Other Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# E. SHUTTERS 1.Accordion 2.Bahama 3. Storm panels 4. Colonial 5.Roll up 6.Equipment 7. Other F. STRUCTURAL COMPONENTS 1. Wood connector/anchor 5 � , s�� "Z3 c S" 2. Truss plates 3. Engineered lumber Ce‘ �,c: ,_ Ff_X,1,7, 1 4. Railing 5. Coolers-freezers 6. Concrete admixtures 7. Material 8. Insulation forms 9. Plastics 10. Deck-roof 11. Wall 12. Sheds 13. Other G. SKYLIGHTS 1. Skylight 2. Other Category/Subcategory Manufacturer Product Description !Limitation of Use State# Local# H. NEW EXTERIOR ENVELOPE PRODUCTS 1. 2. In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation mstruc ions • ong wi i r • ..I - I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. (Contractor Name) (Print Name) IZak��-- '��``�` � (Signature) Company Name: �r��-q � �� ��St LL Mailing Address: City: &-`-V ` 11 I ` State: c� . Zip Code: _-_J S a, Telephone Number: ( )' Fax Number: ( c-`(\'`. \\`' Cell Phone Number: (�`-1 ) 2„/„ `��- H c E-mail Address: ro-\�Q '` 'J Usk- ex 15 --/--a74, , -1' -Flo ri-dc? FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: PARADISE PRESERVE LOT 27 Builder Name: Marco Heating&Air Inc Street: Permit Office: DUVAL CNTY City,State,Zip: ATLANTIC BEACH,FL,32233 Permit Number: Owner: SPRINGFIELD BUILDERS.LLC Jurisdiction: 261300 Design Location: FL,Jacksonville County: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(3000.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=15.0 2640.00 ft2 b. Frame-Wood,Adjacent R=13.0 360.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1531.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 1448.00 ft2 6. Conditioned floor area above grade(ft2) 2777 b.Under Attic(Vented) R=19.0 83.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(377.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 249 a. U-Factor: Dbl,U=0.34 377.00 ft2 b.Sup: Attic,Ret:Attic,AH:Attic 6 306 SHGC: SHGC=0.24 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 22.2 SEER:14.50 b.Central Unit 22.2 SEER:14.50 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 22.2 HSPF:8.20 SHGC: b.Electric Heat Pump 22.2 HSPF:8.20 Area Weighted Average Overhang Depth: 4.499 ft. Area Weighted Average SHGC: 0.240 14.Hot water systems 8. Floor Types (2776.0 sqft.) Insulation Area a. Electric Cap:40 gallons EF:0.999 a.Slab-On-Grade Edge Insulation R=0.0 1245.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 1122.00 ft2 None c.other(see details) R= 409.00 ft2 15.Credits CF, Pstat Total Proposed Modified Loads: 71.61 PASS Glass/Floor Area: 0.136 Total Baseline Loads: 74.43 I hereby certify that the plans and specifications covered by Review of the plans and :.•�� TNE Srq?F.,•.. this calculation are in compliance with the Florida Energy specifications covered by this ' ti r _ O Lb.�.,.�.db„Dt,� % , .-7-':z..••. .n Code. ��»� �•M��g•a m.••... calculation indicates compliance c „ • = r�; Dorothy Deane R..°°e7: "";: with the Florida Energy Code. 3 fr:`ui,,, : :w,-,:,, ,,:0 Locaton PREPARED BY: d 1°°'-12134,. Before construction is completed 1 1' •, . ...�yt�i 'r DATE: this buildingwill be inspected for ` c. `_ i"'' `may d ' P 'st7+. I 'mac compliance with Section 553.908 °; ' + ° .. 'r I hereby certify that thi- bulling, Is d,si?+, is in compliance Florida Statutes. �;••tl ' �..,\c,•.: with the Florida Ener. Co. OD • y 'fi,.• OWNER/AGENT: BUILDING OFFICIAL: ,2 "'•.......... DATE: -__ - 7-/4/-/e DATE: 2-'6•&20/ r - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 7/12/2018 1:35 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: PARADISE PRESERVE LOT 27 Builder Name: Marco Heating&Air Inc Street: Permit Office: DUVAL CNTY City,State,Zip: ATLANTIC BEACH,FL,32233 Permit Number: Owner: SPRINGFIELD BUILDERS.LLC Jurisdiction: 261300 Design Location: FL,Jacksonville County: Duval(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(3000.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame Wood,Exterior R=15.0 2640.00 ft2 b. Frame-Wood,Adjacent R=13.0 360.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1531.0 sqft.) Insulation Area a.Under Attic(Vented) R=38.0 1448.00 ft2 6. Conditioned floor area above grade(ft2) 2777 b.Under Attic(Vented) R=19.0 83.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(377.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 249 a. U-Factor: Dbl,U=0.34 377.00 ft2 b. Sup: Attic,Ret:Attic,AH:Attic 6 306 SHGC: SHGC=0.24 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 22.2 SEER:14.50 b.Central Unit 22.2 SEER:14.50 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 22.2 HSPF:8.20 SHGC: b. Electric Heat Pump 22.2 HSPF:8.20 Area Weighted Average Overhang Depth: 4.499 ft. Area Weighted Average SHGC: 0.240 14.Hot water systems a.Electric Cap:40 gallons 8. Floor Types (2776.0 sqft.) Insulation Area EF:0.999 a.Slab-On-Grade Edge Insulation R=0.0 1245.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 1122.00 ft2 None c.other(see details) R= 409.00 ft2 15.Credits CF,Pstat Total Proposed Modified Loads: 71.61 PASS Glass/Floor Area: 0.136 Total Baseline Loads: 74.43 I hereby certify that the plans and specifications covered by Review of the plans and ,;:..0�'CNE STA*'....,. this calculation are in compliance with the Florida Energy specifications covered by this ; O ' �.. = 74, Code. ' FUS.W='M'°"..hp„ calculation indicates compliance //:?,s;„/",:t.'4:: �,,, _; �+ Dorothy Deane ,'':,--.;?:%.--E,:717„7,�.., with the Florida Energy Code. :J1,,,, ': � .;t;S...1 PREPARED BY: a`;.°p;„°, 21341. Before construction is completed c ra '. :.....:1,.. .....1.r..o DATE: this building will be inspected for 0`;_� i =,.1 p compliance with Section 553.908 %_ ° Florida Statutes. 1`' �" . ' I hereby certify that thi• buil,ing, :s d'si ,, is in compliance .. .. vc, . with the Florida Ener. C•I C00 WE- ••' OWNER/AGENT: BUILDING OFFICIAL: IVI DATE: -7-/6-78 DATE: -G. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 7/12/2018 1:35 PM EnergyGauge®USA Section R405.41 Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: PARADISE PRESERVE LOT Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 2777 Lot# 27 Owner Name: SPRINGFIELD BUILDERS.L Total Stories: 2 Block/Subdivision: PARADISE PRESER #of Units: 1 Worst Case: No PlatBook: Builder Name: Marco Heating&Air Inc Rotate Angle: 0 Street: Permit Office: DUVAL CNTY Cross Ventilation: No County: Duval Jurisdiction: 261300 Whole House Fan: No City,State,Zip: ATLANTIC BEACH, Family Type: Single-family FL, 32233 New/Existing: New(From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 UP 1531 12248 2 DOWN 1246 12460 SPACES Number Name Area Volume Kitchen Occupants Bedrooms lnfil ID Finished Cooled Heated 1 MAIN 1246 12460 Yes 1 1 1 Yes Yes Yes 2 BEDS 1531 12248 No 4 3 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge lnsulatio MAIN 128 ft 0 1245 ft2 ____ 0.3 0.3 0.4 2 Floor over Garage BEDS ____ ____ 409 ft2 0 0.3 0.3 0.4 3 Floor Over Other Space BEDS ____ ____ 1122 ft2 0 0.3 0.3 0.4 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1761 ft2 0 ft2 Medium 0.9 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1575 ft2 N N 7/12/2018 1:35 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING V # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) BEDS 38 Blown 1448 ft2 0.1 Wood 2 Under Attic(Vented) BEDS 19 Blown 83 ft2 0.11 Wood WALLS VAdjacent Cavity Width Height Sheathing Framing Solar Below # Ornt To Wall Type Space R-Value Ft In Ft In Area R-Value Fraction Ahsor Grade% 1 N Exterior Frame-Wood MAIN 15 39 0 10 0 390.0 ft2 0 0.23 0.01 0 2 E Exterior Frame-Wood MAIN 15 43 0 10 0 430.0 ft2 0 0.23 0.01 0 3 S Exterior Frame-Wood MAIN 15 19 0 10 0 190.0 ft2 0 0.23 0.01 0 4 W Exterior Frame-Wood MAIN 15 27 0 10 0 270.0 ft2 0 0.23 0.01 0 5 W Garage Frame-Wood MAIN 13 16 0 10 0 160.0 ft2 0 0.23 0.01 0 6 S Garage Frame-Wood MAIN 13 20 0 10 0 200.0 ft2 0 0.23 0.01 0 7 N Exterior Frame-Wood BEDS 15 39 0 8 0 312.0 ft2 0 0.23 0.01 0 8 E Exterior Frame-Wood BEDS 15 46 0 8 0 368.0 ft2 0 0.23 0.01 0 9 S Exterior Frame-Wood BEDS 15 39 0 8 0 312.0 ft2 0 0.23 0.01 0 10 W Exterior Frame-Wood BEDS 15 46 0 8 0 368.0 ft2 0 0.23 0.01 0 DOORS V # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated MAIN None .35 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.34 0.24 N 12.0 ft2 12 ft 0 in 2 ft 0 in None Exterior 5 2 N 1 Vinyl Low-E Double Yes 0.34 0.24 N 72.0 ft2 4 ft 0 in 2 ft 0 in None Exterior 5 3 N 1 Vinyl Low-E Double Yes 0.34 0.24 N 48.0 ft2 12 ft 0 in 2 ft 0 in None Exterior 5 4 E 2 Vinyl Low-E Double Yes 0.34 0.24 N 12.0 ft2 2 ft 0 in 12 ft 0 in None Exterior 5 5 E 2 Vinyl Low-E Double Yes 0.34 0.24 N 8.0 ft2 2 ft 0 in 12 ft 0 in None Exterior 5 6 S 3 Vinyl Low-E Double Yes 0.34 0.24 N 36.0 ft2 7 ft 6 in 2 ft 0 in None Exterior 5 7 W 4 Vinyl Low-E Double Yes 0.34 0.24 N 12.0 ft2 2 ft 0 in 12 ft 0 in None Exterior 5 8 N 7 Vinyl Low-E Double Yes 0.34 0.24 N 32.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 9 N 7 Vinyl Low-E Double Yes 0.34 0.24 N 45.9 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 10 E 8 Vinyl Low-E Double Yes 0.34 0.24 N 11.9 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 11 E 8 Vinyl Low-E Double Yes 0.34 0.24 N 30.6 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 12 S 9 Vinyl Low-E Double Yes 0.34 0.24 N 6.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 13 S 9 Vinyl Low-E Double Yes 0.34 0.24 N 8.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 14 S 9 Vinyl Low-E Double Yes 0.34 0.24 N 30.6 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 15 W 10 Vinyl Low-E Double Yes 0.34 0.24 N 12.0 ft2 2 ft 0 in 2 ft 0 in None Exterior 5 7/12/2018 1:35 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 5 • FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE V # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 409.05 ft2 409.05 ft2 44 ft 10 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000396 2882.6 158.25 297.61 .3844 7 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.2 22.2 kBtu/hr 2 sys#1 2 Electric Heat Pump/ Split HSPF:8.2 22.2 kBtu/hr 1 sys#2 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 14.5 22.2 kBtu/hr cfm 0.7 2 sys#1 2 Central Unit/ Split SEER: 14.5 22.2 kBtu/hr cfm 0.7 1 sys#2 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Attic 0.999 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM , V FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Supply— —Retum— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 249 ft2 Attic 62 ft2 Default Leakage Attic (Default) (Default) 1 1 2 Attic 6 306 ft2 Attic 77 ft2 Default Leakage Attic (Default) (Default) 2 2 7/12/2018 1:35 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling Jan Feb 1 Mar Apr Ma X Jun X Jul Au X Se Oct Nov Dec HeatingJan X)Feb 'X'MarApr Ma Jun Jul Au Se Oct X Nov Dec VentinJan Feb X' Mar X; r May Jun Jul Aug Sep X Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 MAIN Default(8 lbs/sq.ft. ft2 ft 0.3 BEDS Name: Test Rater Signature: Rating Compant: Test Rater Date: 7/12/2018 1:35 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New(From Plans) 12. Ducts, location&insulation level a)Supply ducts R 6.0 2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location Attic/Attic 3. No. of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 44.4 a)Split system SEER 14.5 5. Is this a worst case?(yes/no) 5. No b)Single package SEER c)Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 2777 d) Room unit/PTAC EER e) Other 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.340 b) Solar Heat Gain Coefficient(SHGC) 7b. 0.240 14. Heating system: Capacity 44.4 c)Area 7c. 377.0 a) Split system heat pump HSPF 8.2 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other 9. Floor type, insulation level: a) Slab-on-grade(R-value) 9a. 0.0 b)Wood, raised (R-value) 9b. 0.0 15.Water heating system c)Concrete, raised (R-value) 9c. a) Electric resistance EF 1.00 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. 15.0 e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. f) Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame(Insulation R-value) 10B1. 13.0 2. Masonry(Insulation R-value) 1082. 16. HVAC credits claimed(Performance Method) 11. Ceiling type and insulation level a)Ceiling fans Yes a) Under attic 11a. varies b)Cross ventilation No b)Single assembly 11b. c)Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home ••mplied with the F . ida Building Code, Energy Conservation,through the above energy saving features whi 'II b• installed or ceede. in this home before final inspection. Otherwise, a new EPL display card will be om�pl: ed base. • 'stalled c..e compliant features. Builder Signatur- / 7111111" Date: -7-/lo - /6? Address of New Home: City/FL Zip: ATLANTIC BEACH, FL 32233 7/12/2018 1:37:05 PM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS 3462 CORMORANT COVE DR Permit Number: JACKSONVILLE ,FL,32223 MANDATORY REQUIREMENTS See individual code sections for full details. I SECTION R401 GENERAL R401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) L�1 display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. dR402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. Ei R402.4.1 Building thermal envelope building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. / The sealing methods between dissimilar materials shall allow for differential expansion and contraction. 2 R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance uJ with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be tumed off. / 6.Supply and retum registers,if installed at the time of the test,shall be fully open. rR402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where LLLJJI using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the 7 fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. ® R402.4.3 Fenestration air leakage Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 L/s/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 5/9/2018 10:04 AM EnergyGauge®USA -FBC 6th Edition(2017) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) 8402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. EiR402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. d4SECTION R403 SYSTEMS 03.1 Controls. / 8403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. N R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls LLL�JJddd that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or (7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. EiR403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing(Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. 403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. RR . E3‘403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) ibelow 55°F(13°C)shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. 12( R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. / Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. 1,( R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return u pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. • R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 5/9/2018 10:04 AM EnergyGauge®USA -FBC 6th Edition(2017)Compliant Software Page 2 of 5 IV�ANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3%2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies(Mandatory). I 1 R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable LLLIII��� of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature / setting range shall be from 100°F to 140°F(38°C to 60°C). rel/ R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to LLL111111 electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main bumer(s)of combustion types of service water-heating systems to be turned off. R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. VR403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation including:Natural,Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that D close when the ventilation system is not operating. R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be R( powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10 otherwise. a//R403.7 Heating and cooling equipment(Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMUM (CFM) (CFM/WATT) (CFM) Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom,utility room 10 1.4 cfm/watt <90 Bathroom,utility room 90 2.8 cfm/watt Any For SI: 1 cfm=28.3 L/min. a. When tested in accordance with HVI Standard 916 5/9/2018 10:04 AM EnergyGauge®USA -FBC 6th Edition(2017) Compliant Software Page 3 of 5 M NDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. El R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. l/ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall.be sized within 4 kW of the design ���---666rrr requirements calculated according to the procedure selected in Section R403.7.1 1:-/ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. I:/ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8°C). dTheR403.10 Pools and permanent spa energy consumption(Mandatory). energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. ITh R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an LLLYYY III integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously buming ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically tum off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. ©/ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. rilR403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 5/9/2018 10:04 AM EnergyGauge®USA -FBC 6th Edition(2017) Compliant Software Page 4 of 5 / 0 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas(Mandatory)he energy consumption of electric-powered portable spas shall be controlled by the "Li requirements of APSP-14. SECTION R404 E ECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception:Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory).Fuel gas lighting systems shall not have continuously burning pilot lights. • 5/9/2018 10:04 AM EnergyGauge®USA -FBC 6th Edition(2017) Compliant Software Page 5 of 5 2017-AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: PARADISE PRESERVE LOT 27 Builder Name: Marco Heating&Air Inc Street: Permit Office: DUVAL CNTY City,State,Zip: ATLANTIC BEACH,FL,32233 Permit Number: Owner: SPRINGFIELD BUILDERS.LLC Jurisdiction: 261300 Design Location: FL,Jacksonville 0 COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and anygaps in the air barrier shall be sealed. 9 P shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids betwec n fire sprinkler cover plates and walls or ceilings a. In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 7/12/2018 1:37 PM EnergyGauge®USA FBC 6th Edition(2017)Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: 261300 Permit#: Job Information Builder: Marco Heating &Air Inc Community: Lot: 27 Address: City: ATLANTIC BEACH State: FL Zip: 32233 Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method O PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g. (50 Pascals)in Climate Zones 1 and 2. O PERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on Form R405-2017(Performance)or R406-2017(ERI),section labeled as infiltration,sub-section ACH50. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): 7 000 x 60 _ 24708 = Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans PASS •Code software calculated When ACH(50)is less than 3, Mechanical Ventilation installation O Field measured and calculated ' must be verified by building department. R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be dosed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers induding exhaust,intake,makeup air,back draft and flue dampers shall be dosed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification#: Issuing Authority: 7/12/2018 1:37:25 PM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 BuildingAnalysis Job: PARADISE PRESERVE LO... 4i- wrightsoft y Date: JULY 12,2018 Entire House By: MARCO HEATING&AIR Marco Heating & Air Inc Plan: 2759 SQ FT 720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 Web:MARCOCOMPANIES.COM License:CAC1815711 Pro'ect Information For: PARADISE PRESERVE LOT 27, SPRINGFIELD BUILDERS. LLC ATLANTIC BEACH, FL 32233 Desi• n Conditions Location: Indoor: Heating Cooling Jacksonville Intl AP, FL, US Indoor temperature(°F) 70 75 Elevation: 33 ft Design TD(°F) 38 18 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 11.0 51.2 Drybulb(°F) 33 93 Infiltration: Daily range (°F) - 18 ( M ) Method Simplified Wetbulb(°F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btu h/ft2 Btuh %of load Walls 3.2 8367 24.6 Glazing 12.8 4807 14.1 QIctS Doors 14.6 702 2.1 Ceilings 1.0 1536 4.5 Floors 3.8 5960 17.5 Infiltration 2.1 5429 16.0 Ducts 7185 21.1 Gazing *kfitralEn Piping 0 0 Humidification 0 0 BAs Boas Ventilation 0 0 Adjustments 0 Total 33985 100.0 Coolin• Component Btu h/ft2 Btuh %of load Walls 1.9 4935 16.0 Glazing 13.6 5135 16.6 Doors C�r1s Doors 11.8 565 1.8 WI Ceilings 1.4 2199 7.1 Floors 0.1 93 0.3 Infiltration 0.5 1281 4.1 ClairL__ Ducts 9972 32.2 Ventilation 0 0 Internal gains 6750 21.8 (Ito- Blower thaBlower 0 0 Cali is Adjustments 0 !dab-Aim Total 30931 100.0 Latent Cooling Load=9539 Btuh Overall U-value=0.094 Btuh/ft2-°F Data entries checked. lid- . - ttsot2018-Jul-12 13.35:18 t .!h• tt` Right-Suite®Universal 2018 18.0.16 RSU17889 Page 1 ACOA ...DAVISIPARADISE'LOT 271BUCKY DAVIS 2777 SQFT.rup Calc=MJ8 Front Door faces: S -4 wrightsoftRight-J® Worksheet Job: PARADISE PRESERVE LOT 27 Entire House Date: JULY 12,2018 By: MARCO HEATING&AIR Marco Heating &Air Inc Plan: 2759 SQ FT 720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 Web:MARCOCOMPANIES.COM License:CAC1815711 1 Room name Entire House UP 2 Exposed wall 298.0 ft 170.0 ft 3 Room height 8.9 ft 8.0 ft 4 Room dimensions 5 Room area 2777.0 ft' 1531.0 ft' I Ty ' Construction I U-value Or I HTMI Area (ft') Load I Area (ft') Load number (Bt uh/ft'-'F (Bt uh/fr) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool I Gross I N/P/S Heat I Cool I Gross I N/P/S Heat I Cool 6 V/ 12D-Osw 0.086 n 3.23 2.00 702 492 1587 982 312 234 755 467 . -G 4A5-2ov 0.340 n 12.75 9.90 32 0 408 317 32 0 408 317 . -G 4A5-2ov 0.340 n 12.75 9.90 12 0 153 119 0 0 0 0 -(' 4A5-2ov 0.340 n 12.75 9.90 46 0 585 454 48 0 585 454 11 -C 4A5-2ov 0.340 n 12.75 9.90 72 0 918 712 0 0 0 0 -G 4A5-2ovd 0.340 n 12.75 9.90 48 0 612 475 0 0 0 0 W 12D-Osw 0.086 e 3.23 2.00 798 736 2372 1467 368 326 1050 649 -G 4A5-2ov 0.340 e 12.75 26.13 12 0 153 314 0 0 0 0 -G 4A5-2ov 0.340 e 12.75 26.13 8 0 102 209 0 0 0 0 -G 4A5-2ov 0.340 e 12.75 26.13 12 0 152 311 12 0 152 311 --G 4A5-2ov 0.340 e 12.75 26.13 31 0 390 800 31 0 390 800 12D-Osw 0.086 s 3.23 2.00 502 397 1282 793 312 267 862 534 4A5-2ov 0.340 s 12.75 9.90 6 6 77 59 6 6 77 59 4A5-2ov 0.340 s 12.75 9.90 8 8 102 79 8 8 102 79 4A5-2ov 0.340 s 12.75 9.90 31 31 390 303 31 31 390 303 4A5-2ov 0.340 s 12.75 9.90 36 36 459 356 0 0 0 0 D 11D0 0.390 s 14.62 11.78 24 24 351 283 0 0 0 0 VJ 1213-0sw 0.086 w 3.23 2.00 638 614 1980 1225 368 356 1148 710 -(' 4A5-2ov 0.340 w 12.75 26.13 12 0 153 314 12 0 153 314 -(' 4A5-2ov 0.340 w 12.75 26.13 12 0 153 314 0 0 0 0 R 12C-Osw 0.091 - 3.41 1.39 360 336 1147 468 0 0 0 0 0 1100 0.390 n 14.62 11.78 24 24 351 283 0 0 0 0 C 16B-38ad 0.026 - 0.98 1.40 1575 1575 1536 2199 1531 1531 1493 2138 F 19C-19cscp 0.049 - 0.64 0.30 310 310 197 93 310 310 197 93 F 22A-tpm 1.180 - 44.25 0.00 1266 130 5762 0 20 2 98 0 c)AED excursion 0 6 I Envelope loss/gain I I 213711 12928 I 7860 7228 12 a) Infiltration 5429 1281 2797 660 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 5 1150 4 920 Appliances/other 5600 1200 Subtotal(lines 6 to 13) 26800 20959 10657 10008 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 26800 20959 10657 10008 15 Duct loads 27% 48% 7185 9972 35% 52% 3762 5226 Airareqmoth red(ad dm) I I 1 314801 4801 I 1 1 401 15740 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -+* wrlip►staoft- 2018-Jul-12 13:35:19 .--�� •- •- -• Right-Su fie®Universal 2018 18.0.16 RSU17889 Page 1 ...DAVIS\PARADISE\LOT 27\BUCKY DAVIS 2777 SQFT.nrp Calc=MJ8 Front Door faces: S 4 wrightsoft Right-J® Worksheet Job: PARADISE PRESERVE LOT 27 Entire House Date: JULY 12, 2018 By: MARCO HEATING&AIR Marco Heating &Air Inc Plan: 2759 SQ FT 720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 Web:MARCOCOMPANIES.COM License:CAC1815711 1 Room name DOWN 2 Exposed wall 128.0 ft 3 Room height 10.0 ft 4 Room dimensions 5 Room area 1246.0 ft' t I I t Ty Construction U-value Or 1 HTM Area (ft') Load 1 Area Load number (Btuh/ft'-°F (Btuh/ft') I or perimeter (ft) I (Btuh) or perimeter Heat 1 Cool I Gross I N/P/S I Heat I Cool I Gross I N/P/S Heat Cool 6 W 12D-Osw 0.086 n 3.23 2.00 390 258 832 515 . -G 4A5-2ov 0.340 n 12.75 9.90 0 0 0 0 . -G 4A5-2ov 0.340 n 12.75 9.90 12 0 153 119 -G 4A5-2ov 0.340 n 12.75 9.90 0 0 0 0 11 .-/3 4A5-2ov 0.340 n 12.75 9.90 72 0 918 712 -G 4A5-2ovd 0.340 n 12.75 9.90 48 0 612 475 W 12D-Osw 0.086 e 3.23 2.00 430 410 1322 818 -G 4A5-2ov 0.340 e 12-75 26.13 12 0 153 314 -13 4A5-2ov 0.340 e 12.75 26.13 8 0 102 209 -G 4A5-2ov 0.340 e 12.75 26.13 0 0 0 0 -G 4A5-2ov 0.340 e 12.75 26.13 0 0 0 0 12D-Osw 0.086 s 3.23 2.00 190 130 419 259 4A5-2ov 0.340 s 12.75 9.90 0 0 0 0 4A5-2ov 0.340 s 12.75 9.90 0 0 0 0 4A5-2ov 0.340 s 12.75 9.90 0 0 0 0 4A5-2ov 0.340 s 12.75 9.90 36 36 459 356 ii 11D0 0.390 s 14.62 11.78 24 24 351 283 W 12D-Osw 0.086 w 3.23 2.00 270 258 832 515 -C 4A5-2ov 0.340 w 12.75 26.13 0 0 0 0 -G 4A5-2ov 0.340 w 12.75 26.13 12 0 153 314 Pi 12C-Osw 0.091 - 3.41 1.39 360 336 1147 468 D 11D0 0.390 n 14.62 11.78 24 24 351 283 C 16B-38ad 0.026 - 0.98 1.40 44 44 43 61 F 19C-19cscp 0.049 - 0-64 0.30 0 0 0 0 F 22A-tom 1.180 - 44.25 0.00 1246 128 5664 0 6 c)AED excursion I 0 Envelope loss/gain 13511 5700 12 a) Infiltration 2632 621 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 1 230 Appliances/other 4400 Subtotal(lines 6 to 13) 16143 10951 • Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 16143 10951 15 Duct loads 21% 43% 3423 4746 I1 TAAir rel quir dl(cfrn) 19740 15740 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -44/- wraphtsoV 2018-Jul-1213:35:19 ,...& •- - ----- --• Right-Suite®Universal 2018 18.0.16 RSU1 7889 Page 2 ...DAVIS\PARADISE\LOT 27\BUCKY DAVIS 2777 SQFT.rup Calc=MJS Front Door faces S Project SummaryJob: PARADISE PRESERVE LO... wrightsoftDate: JULY 12,2018 Entire House By: MARCO HEATING&AIR Marco Heating & Air Inc Plan: 2759 SQ FT 720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 Web:MARCOCOMPANIES.COM License:CAC1815711 Pro'ect Information For: PARADISE PRESERVE LOT 27, SPRINGFIELD BUILDERS. LLC ATLANTIC BEACH, FL 32233 Notes: ORIENTATION-SOUTH-FRONT DOOR DN 2.0 TON 5KW UP 2.0 TON 5KW Desi• n Information Weather: Jacksonville Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 33 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 % Moisture difference 51 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 26800 Btuh Structure 20959 Btuh Ducts 7185 Btuh Ducts 9972 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 33985 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 30931 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 7189 Btuh Ducts 2350 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling Area(ft2) 2777 2777 Equipment latent load 9539 Btuh Volume(ft3) 24706 24706 Air changes/hour 0.32 0.16 Equipment Total Load (Sen+Lat) 40470 Btuh Equiv.AVF (cfm) 132 66 Req.total capacity at 0.70 SHR 3.7 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrlphtsott 2018-Jul-1213:34:12 - Right-Suite®Universal 2018 18.0.16 RSU17889 Page 1 AC ...DAVIS\PARADISE\LOT 27\BUCKY DAVIS 2777 SQFT.rup Calc=MJB Front Door faces: S Project SummaryJob: PARADISE PRESERVE LO... 4wrightsoftDate: JULY 12,2018 DOWN By: MARCO HEATING&AIR Marco Heating & Air Inc Plan: 2759 SQ FT 720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 Web:MARCOCOMPANIES.COM License:CAC1815711 Pro'ect Information For: PARADISE PRESERVE LOT 27, SPRINGFIELD BUILDERS. LLC ATLANTIC BEACH, FL 32233 Notes: ORIENTATION-SOUTH-FRONT DOOR DN 2.0 TON 5KW UP 2.0 TON 5KW Desi• n Information Weather: Jacksonville Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 33 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 % Moisture difference 51 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16143 Btuh Structure 10951 Btuh Ducts 3423 Btuh Ducts 4746 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 19566 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 15698 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3710 Btuh Ducts 1115 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1246 1246 Equipment latent load 4825 Btuh Volume(ft3) 12458 12458 Air changes/hour 0.31 0.15 Equipment Total Load (Sen+Lat) 20523 Btuh Equiv.AVF (cfm) 64 32 Req.total capacity at 0.70 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade 14 SEER HP Trade 14 SEER HP Model 25HCE424A00300 Cond 25HCE424A00300 AHRI ref 9674745 Coil FB4CNP025L AHRI ref 9674745 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14.5 SEER Heating input Sensible cooling 15540 Btuh Heating output 22200 Btuh @ 47°F Latent cooling 6660 Btuh Temperature rise 27 °F Total cooling 22200 Btuh Actual air flow 740 cfm Actual air flow 740 cfm Air flow factor 0.038 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.76 Capacity balance point=31 °F Backup: Input=5 kW, Output= 16971 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _®1 wripto !1stt- 2018-Jul-12 13:34:12 ,.—�,_ •_..- ------ -._. Right-Suite®Universal 2018 18.0.16 RSU17889 Page A� ...DAVIS\PARAD!SRL OT 27\BUCKY DAVIS 2777 SOFT.rup Calc=MJ8 Front Door faces: S Project Summa Job: PARADISE PRESERVE LO... + wrightsoft Date: JULY 12,2018 UP By: MARCO HEATING&AIR Marco Heating & Air Inc Plan: 2759 SQ FT 720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 Web MARCOCOMPANIES.COM License:CAC1815711 Pro'ect Information For: PARADISE PRESERVE LOT 27, SPRINGFIELD BUILDERS. LLC ATLANTIC BEACH, FL 32233 Notes: ORIENTATION-SOUTH-FRONT DOOR DN 2.0 TON 5KW UP 2.0 TON 5KW Desi• n Information Weather: Jacksonville Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 33 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 % Moisture difference 51 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 10657 Btuh Structure 10008 Btuh Ducts 3762 Btuh Ducts 5226 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 14419 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 15233 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3479 Btuh Ducts 1234 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 153T 1531 Equipment latent load 4713 Btuh Volume (ft') 12248 12248 Air changes/hour 0.33 0.17 Equipment Total Load (Sen+Lat) 19947 Btuh Equiv. AVF (cfm) 68 34 Req.total capacity at 0.70 SHR 1.8 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade 14 SEER HP Trade 14 SEER HP Model 25HCE424A00300 Cond 25HCE424A00300 AHRI ref 9674745 Coil FB4CNP025L AHRI ref 9674745 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14.5 SEER Heating input Sensible cooling 15540 Btuh Heating output 22200 Btuh @ 47°F Latent cooling 6660 Btuh Temperature rise 27 °F Total cooling 22200 Btuh Actual air flow 740 cfm Actual air flow 740 cfm Air flow factor 0.051 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.76 Capacitybalance point=23°F Backup: Input=4 kW, Output= 14079 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wt righsof!- 2018-Jul-1213:34:12 1 .-... _. ... ___ Right-Suite®U niversal 2018 18.0.16 RSU17889 Page ACS+ ...DAVIS\PARADISE\LOT 27\RUCKY DAVIS 2777 SQFT.rup Calc=MJ8 Front Door faces: S Manual S Compliance Report Job: PARADISE PRESERVE LO... + wrightsoft Date: JULY 12,2018 DOWN By: MARCO HEATING&AIR Marco Heating & Air Inc Plan: 2759 SQ FT 720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 Web:MARCOCOMPANIES.COM License:CAC1815711 Project Information For: PARADISE PRESERVE LOT 27, SPRINGFIELD BUILDERS. LLC ATLANTIC BEACH, FL 32233 Cooling Equipment Design Conditions Outdoor design DB: 92.7°F Sensible gain: 15698 Btuh Entering coil DB: 77.9°F Outdoor design WB: 77.1°F Latent gain: 4825 Btuh Entering coil WB: 64.0°F Indoor design DB: 75.0°F Total gain: 20523 Btuh Indoor RH: 50% Estimated airflow: 740 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HCE424A00300+FB4CNP025L Actual airflow: 740 cfm Sensible capacity: 15540 Btuh 99%of load Latent capacity: 6660 Btuh 138%of load Total capacity: 22200 Btuh 108%of load SHR: 70% Heating Equipment Design Conditions Outdoor design DB: 32.5°F Heat loss: 19566 Btuh Entering coil DB: 68.5°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HCE424A00300+FB4CNP025L Actual airflow: 740 cfm Output capacity: 17556 Btuh 90%of load Capacity balance: 31 °F Supplemental heat required: 2010 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 740 cfm Output capacity: 5.0 kW 87%of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. wrightsoft` 2018-Jul-12 13:34:12 Right-Suite®Universal 2018 18.0.16 RSU17889 Page 1 /9:1•.•'QI� ...DAVIS\PARADISE\LOT 27\BUCKY DAVIS 2777 SQFT.rup Calc=MJ8 Front Door faces: S Manual S Compliance Report Job: PARADISE PRESERVE LO... + wrightsoft Date: JULY 12,2018 UP By: MARCO HEATING&AIR Marco Heating & Air Inc Plan: 2759 SQ FT 720 Mill Creek Rd,Jacksonville,FL 32211 Phone:904-743-3350 Fax:904-743-4427 Web:MARCOCOMPANIES.COM License:CAC1815711 Project Information For: PARADISE PRESERVE LOT 27, SPRINGFIELD BUILDERS. LLC ATLANTIC BEACH, FL 32233 Cooling Equipment Design Conditions Outdoor design DB: 92.7°F Sensible gain: 15233 Btuh Entering coil DB: 78.2°F Outdoor design WB: 77.1°F Latent gain: 4713 Btuh Entering coil WB: 64.1°F Indoor design DB: 75.0°F Total gain: 19947 Btuh Indoor RH: 50% Estimated airflow: 740 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HCE424A00300+FB4CNP025L Actual airflow: 740 cfm Sensible capacity: 15540 Btuh 102%of load Latent capacity: 6660 Btuh 141%of load Total capacity: 22200 Btuh 111%of load SHR: 70% Heating Equipment Design Conditions Outdoor design DB: 32.5°F Heat loss: 14419 Btuh Entering coil DB: 68.4°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HCE424A00300+FB4CNP025L Actual airflow: 740 cfm Output capacity: 17563 Btuh 122%of load Capacity balance: 23 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 740 cfm Output capacity: 4.1 kW 98%of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. -4- wrightsoft- 2018-Jul-12 13:34:12 �^tJC� _ . ..... _ _.-. Right-Suite®Universal 2018 18.0.16 RSU17889 Page 2 /�+� ...DAVIS\PARADISE\LOT 27\BUCKY DAVIS 2777 SQFT.nip Calc=MJ8 Front Door faces: S SPRINGFIELD BUILDERS PLAN: CUSTOM 2759 SF LOT#: 27 SUBDIVISION: PARADISF PRFSFRVF CARRIER _2.0_TON HEAT PUMP SYSTEM SEER: 14 HSPF: 8.2 CARRIER 2.0 TON HEAT PUMP SYSTEM SEER: 14 HSPF: 8.2 DESIGN COOL BTUH: 54000 AVAILABLE STATIC PRESSURE: 1.1 TOTAL CFM: 1935 TOTAL EFFECTIVE LENGTH: 295 PERFORMANCE METHOD: DUCT MATERIAL: R6 VINYL FLEX SUPPLY BRANCH DETAIL TABLE ROOM NAME COOLING CFM BRANCH SIZE LINEAR FT DUCT MATERIAL LOFT 165 CFM 7" 10' VINYL FLEX DINING 165 CFM 7" 15' VINYL FLEX LIVING ROOM (2) 200 CFM (2) 8" 40' VINYL FLEX KITCHEN 165 CFM 7" 12' VINYL FLEX BATH 3 35 CFM 4" 19' VINYL FLEX LAUNDRY 35 CFM 4" 22' VINYL FLEX BR 4 165 CFM 7" 12' VINYL FLEX BR 4 WIC 35 CFM 4" 12' VINYL FLEX BATH 4 35 CFM 4" 15' VINYL FLEX BR3 165 CFM 7" 20' VINYL FLEX BATH 2 35 CFM 4" 15' VINYL FLEX BR2 165 CFM 7" 15' VINYL FLEX MBR (2) 100 CFM (6) 6" 32' VINYL FLEX MBA 100 CFM 6" 20' VINYL FLEX MBR WIC 35 CFM 4" 15' VINYL FLEX MBA TOILET 35 CFM 4" 21' VINYL FLEX TOTALS 1935 CFM 295 LN (FT) SUPPLY TRUNK DETAIL TABLE LOCATION DESIGN BTUH TRUNK SIZE DUCT MATERIAL FROM UNIT TO 1ST DISTR BOX 12202 10" VINYL FLEX FROM UNIT TO 1ST DISTR BOX 21054 14" VINYL FLEX 1 , . , r VADE SOFF I ABV r"�LI 1-1 I I I ICOVERED PORCH I 1 I 10'47 CLG-STEP I I t8 1.' LINE OF 1 6-4!* lc-2y2. 8 t / FLOOR ABOVE 3'o' t. 3-8X" 3 4' I 3040 SH I 1 96'AFF OPT FFIFACH DR51 I5H 3060 514 3060se AFT 96'AFF se`5H 306FF 0 O.H.C. II'.—O.H.C. I I r I ---�- 111 111 1 tn R AK HANDLER(5) 51NX L 0]�y JI I I g AND 4'`°"`PAD KITCHEN I I •FINAL LOCA?ION I X- BY OTHERS ,-.Ito O LLG v I o c Ii 1 f—�—6.4 2-0"-�I-2-0' t ' I 1 26-0 4'X5'5LAND I _,t 11< 411.2.-Z 1^� 5A5E CABS W/ �! k Mr036' I DINING I I W �� �I 10-0''C1.5 i ; LIVING RM w ' I 1 I 10-C1 cLG t / Of� I I WALL I I ,3 I • I BELOW I I ` 1~ /'' I I ,f_, i I =1 ./'� r-a " n / Tom; 3682.0PNG / a'- 3,-�., a,.6�.� I I g'-ij 9- 7! 12 t� —— 1 st, _ ——— . tc�e2 — ( wc ) 1= ,� W t L V X \ in z \ oc n )) ,., t * V \ Eli _ ��•_Fi i o - 'I PANT jI ��� ACTH a 1 1 la•a.CLG E I I I� I I 5T I 1�� K Ur It 55H R/5 1LR t r ir tl_,' 3-5' S.-0. I i, WIG"' J1 t0 0 CLG OPTLAUNDRY - II2n1MBW12.6 IIS m q" ;;ALL BEHIND 2a-0/' -_-_6-9Y2"—_ -1 '-9Y. T-4X' if ." 2 CAR GARAGE FOYER -0 CIG-SEP 10-0 CLC, BEDROOM t- 2 2::-..)1 * --- ,h`-- .0 FL ABV --- - J - EliiiM =INIIII , 30605H 3, .tr 96"Zi 3'-3' / 3'-3" 71' 4-4' 3'•6' 4'•4' I A I n 1607D 01ENTRY I I I I I 10-0"CLG 451EP I I / 12"50.COI USANTILEYERED POOP ABY I / (TVP) I I b I it W17E 50=F1f ABV 1/ I I I I I +I r1. (nal / r-cr 1-0' i / 6-6' 10-2" / 8.6' It-2 f LINE Of PORCH BLOW 7 I � I 4040Fx -:, 696"AFF - 5H/BAR a- 30505H 30505H 30505H �� �� 096'AFF 096.AFF 096 A-F 55h ' VHE.AO LL o UNEN • 4.D OLS IN. WIG z 9-7 CLG I ,k`" 9-0"CL6 A� 5'6"x105' • IIOPT TRAY TO 1O-O 3'-7 Z78" --5-4" „ 64y' 77 s G_STOHDR.IBYO/ 1,�2 l_ 42 i/2 WAL_BEA v M.BATH g-0"aG MASTER BGiIV� 1I57ACK Ela J a 9'-0'CLG � - 19.8'z t5'•t0' •'S* x1SF t 'yll l•r 1 L-...i- 111111111111111Z I— 114. L_..1...t N ` N / 141 1 An 4• is 9'-0"CLG 4 I' IN 12-8.x'1'-0" il s�' •g 11 1 1 p I , � � .! • ._- / CKALII ��1P11r' __�T_ Mb UNEN WIG £1 ''y�i '-ekli�ti� rat=1 NB.4/.. 9-0'CLG I, a r.,]:IwR� iraM111111191 () r ix-7::,,,, ELOORORAIN 1,„, __, Ri5 /1111101 111141111111111 II -t - "4,11111‘tAliN°17)" 9-O'aG �- a-6 . 5-6 'moi =ii VA tel `kms. s;=----ii R/5 TUB/ 2.,a. w' " 2030 NICHE o BEDROOM 2 r 0 _n r O'-O CLG - F-b ..� r-6'z'3'-6' m 6, I N I� I ' I-a BEDROOM 3 I ' ,. 4. , � i WC D m I i\ M l0 20505H r .. 30505h 30505H J ? -- ---+� - 054"AFF Q B4"AFF" 1 T 1111111111111t—MEM 1 LL_ a _LJ 3050 SH I CANTILEVER I I 84'AFF .64'AFFI I ., I `–IT ROOF AB1' Il_— —-I ,'1, -- -----G.iRAGE WAIL BELOW Tin ' CANTILEVER — ROOF ABV II 11 LL JJ CANTI_EVER ROOF.SBV r- --- ---- ----J 1 1 L _INE OF PORCH SLOW J -4.4' -/-3-6" / 4..4' / .. ---/ 8'-2" ,R-3'-3" i 4.4. 3-E' 4,.4. i MAP OF BOUNDARY SURVEY DESCRIPTION: LOT 27.PARADISE PRESERVE, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 57, PAGE(S) 31.31A.31B, AND 31C OF THE PUBLIC RECORDS OF OUVAL COUNTY, FLORIDA. F.I.P. 1/2' 1 IL �. e.' 517178.3S761-E 53 00. 14111 E �ei•f r-6.47 F.I.P. 1/2' 11LRIHF �0' �$ SCALE: 1" = 30' EL-6.21' WW iw PALM :IN o ELWE 2 LOT 27 8a EL•917• -q. g W EL-8.77• DEMOTES SOT ELEVATION N1. le PLEVA P1016 ARE ON APROXIM41E LOCATION h 8EICH IM ON LA TRAI6PTAEME,R PAO r= A9.P• LOCATED AT 741 PARADISE La-8.77' o F.I.P.f/2' I$iN W L61 7.5. 61.4.57' 4E4 477178.3.0, �"�M ....... $.OD• By 07 I F.I.P.1R' 8.8.87 1704 of Pq 6 fA7iv,2�Y�A4pl .. �.I .. . 7 PP.4 X70 ..... . SURVEY NOTES: CERTIFIED TO AND FOR THE EXCLUSIVE BENEFIT OF: 01 BEARINGS ARE BASED ON PLAT WITH THE SOUTH LINE OF BUCKY DAVIS LOT 27. BEING N77'08'31'14 02 UNDERGROUND UTILITIES• FOUNDATIONS OR OTHER STREET ADDRESS: IMPROVEMENTS WERE NOT LOCATED BY THIS SURVEY. 741 PARADISE LANE f3 ACCORDING TO THE FEDERAL EMERGENCY MANAGEMENT AGENCY JACKSONVILLE.FLORIDA FIRM MAP PANEL NO. 12031C 0408 H EFFECTIVE 06/03/2013. THE PROPERTY DESCRIBED HEREON APPEARS TO LIE IN ZONE 'X'. /4 THIS SURVEY PERFORMED WITHOUT BENEFIT OF AN ABSTRACT. TITLE SEARCH, TITLE OPINION OR TITLE INSURANCE. /5 DIMENSIONS ARE SHOWN IN FEET AND DECIMALS THEREOF AND ARE PLAT AND MEASURED UNLESS SHOW OTHERWISE. 06 ALL EASEMENTS ARE PER PLA T(MESS SHOWN OTHERWISE. /7 THERE MAY BE ADDITIONAL RESTRICTIONS THAT APPLY WHICH ARE k NOT SHOWN ON THIS SURVEY WHICH CAN BE FOUND IN PUBLIC kRECORDS OF SAID COUNTY. a c 08 THIS SURVEY DOES NOT GUARANTEE OWNERSHIP. T7‘,", f9 TEMPORARY. NON-PERMANENT IMPROVEMENTS AND/OR MAN-MADE ITEMS i SUCH AS, BUT NOT LIMITED TO THE FOLLOWING: BUILDING MATERIAL. 0' STORAGE PODS. PAVER BLOCKS. RUBBERMAID OR PLASTIC UTILITY BUILDINGS NOT ON FOUNDATIONS. VEHICLES ON BLOCKS MAY BE ON THIS PROPERTY BUT NOT LOCATED OR SHOWN. c 010 LEGAL DESCRIPTION PROVIDED BY CLIENT. 0, N 03 NOTICE OF LIABILITY: THIS SURVEY IS CERTIFIED TO THOSE INDIVIDUALS SHOWN ON THE FACE THEREOF. ANY OTHER USE. BENEFIT OR RELIANCE BY ANY OTHER PARTY IS - STRICTLY PROHIBITED AND RESTRICTED. SURVEYOR IS RESPONSIBLE ONLY TO THOSE n CERTIFIED AND HEREBY DISCLAIMS ANY OTHER LIABILITY AND HEREBY RESTRICTS THE ap0E 0. VAN KLEECK RIGHTS OF ANY OTHER INDIVIDUAL OR FIRM TO USE THIS SURVEY. WITHOUT EXPRESS FLORIDA RE675TEIED SLRYEYOR AND NAPPER ND. 2546 WRITTEN CONSENT OF THE SURVEYOR. NOT VALID WITHOUT 71E SI1R4A TUE 6 THE ORIGINAL RAISED .\,.... SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. o z E F.C.M. FDI.M CONCRETE I4AAENT C.M. -CQMCIE7E NOMAENT SEC SECT ON FM FIRE HYDRANT C E.F.-OVER AD ELECTRIC EEEMfC F.I.R.C. FOIAO IRON NDO AHO CAP P.7. -POINT OF 1AhGEACY TMP N IP NV WATER VALVE F F.I.R. P0140 IRON RIO P.C. -POINT ON CURVATURE AGE FMO FOUND M.F. -MOO FEEAE i F.I.P. FDUO IRON PIPE U.E. -UTITLITY EASE1ENT P.I. EF I TION 1Pi FLAT C.B. -CHORD BEARING TER R= S.I.R.C. SET IRON RDD NO CAP D.E. -DRAINAGE EASEMENT A/C A WIC 7 EN ELECTRIC BOX ON - > FASO FOUND NAIL AND DISK C 6 6 -CUM 6 GUTTER NTS T WIC MD -M000 POLE (:CND. CONCRETE -LIGHT POLE R7N OD FIELO ATEDUEASLR C/H -RIGHT OF MAY 6' C.L. CEI CABLE BOX LP NJ (fJ CALCULATED/EASUE/EN7 C/L -CENTERLINE ft' M.F. -i—,—i—,- PB PHONE /BOX M/N -MUf'OLE t�/ FIELD SURVEY DATE \ FIRST COAST LAND \I PROJECT INFORMATION W PLOT PLAN ORDER NO: 29105/29105A 1 BOUNDARY 07/24/2018 SURVEYORS, INC. DRAWN BY: KMP z w FORNBOARO 3161-4 ST JOHNS BLUFF ROAD S. JACKSONVILLE. FL.32246 REVIEWED BY: HF J. FOUNDATION 07/30/2018 NE PHO (904) 779-2062 FAX (904) 779-7784 CHECKED BY: VAN 25 FINALWWW.F CERTIFICATE STLANOSURVEYING.COM 1 \, J 4L—>C►5 - L7\-- 2 i �T-,,,.: r< -4)-i 1--7 7��c.Q.•.,L 1,____0._ MAP OF BOUNDARY SURVEY DESCRIPTION: LOT 27.PARADISE PRESERVE, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 57, PAGE(S) 31,31A.31B, AND 31C OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. F.I.P.1/1' 1 0 nLE ,: ...1.0. SI. S77 Ail � E N E g� (w :'-n. F.I.P.1/o' ,,I. nIEBIB.E 8� O• I °g SCALE: 1" = 39' 0 B.-8.27' act' 66 B.M.0166ELOPE I brEry f ( iLOT 27 - .9.17' Cl' 77 W W EL-8.77' LEIOTES SPOT ELEVATION / 13 U b i ELEVATIONS ARE ON APPROXIMATE LOCATION .0,-... ON 0 n BO. LOCAEDA�41 LA L P8.77• V ��-I F.I.P. 1/2' � I BENCH LB 1 7 5. MIIK a-B.G7• "EI F4S;Hr 10'X10' SS OO.71 07•(N/ a-e.B7� :1701 4Mlp7}j ':: SURVEY NOTES: CERTIFIED TO AND FOR THE EXCLUSIVE BENEFIT OF: 01 BEARINGS ARE BASED ON PLAT WITH THE SOUTH LINE OF LOT 27. BEING N77'08'31"W. BUCKY DAVIS 02 UNDERGROUND UTILITIES, FOUNDATIONS OR OTHER STREET ADDRESS' IMPROVEMENTS WERE NOT LOCATED BY THIS SURVEY. 741 PARADISE LANE 03 ACCORDING TO THE FEDERAL EMERGENCY MANAGEMENT AGENCY JACKSONVILLE FLORIDA FTHEMMAP PROPERTYEL NO.DESCRIBED3HEREONC BAPPEARS TOIVLIE6IN3ZONE3"X'. 04 THIS SURVEY PERFORMED WITHOUT BENEFIT OF AN ABSTRACT. TITLE SEARCH. TITLE OPINION OR TITLE INSURANCE. /5 DIMENSIONS ARE SHOWN IN FEET AND DECIMALS THEREOF ANO ARE PLAT AND MEASURED UNLESS SHOWN OTHERWISE. 06 ALL EASEMENTS ARE PER PLAT UNLESS SHOWN OTHERWISE. /7 THERE MAY BE ADDITIONAL RESTRICTIONS THAT APPLY WHICH ARE u NOT SHOWN ON THIS SURVEY WHICH CAN BE FOUND IN PUBLIC RECORDS OF SAID COUNTY. .5 o OB THIS SURVEY DOES NOT GUARANTEE OWNERSHIP. 09 TEMPORARY. NON-PERMANENT IMPROVEMENTS AND/OR MAN-MADE ITEMS SUCH AS, BUT NOT LIMITED TO THE FOLLOWING; BUILDING MATERIAL, STORAGE PODS, PAVER BLOCKS. RUBBERMAID OR PLASTIC UTILITY =. m BUILDINGS NOT ON FOUNDATIONS. VEHICLES ON BLOCKS MAY BE ON N THIS PROPERTY BUT NOT LOCATED OR SHOWN. c #10 LEGAL DESCRIPTION PROVIDED BY CLIENT. m i ci) m NOTICE OF LIABILITY: THIS SURVEY IS CERTIFIED TO THOSE INDIVIDUALS SHORN ON 9 THE FACE THEREOF. ANY OTHER USE, BENEFIT OR RELIANCE BY ANY OTHER PARTY IS STRICTLY PROHIBITED AND RESTRICTED. SURVEYOR IS RESPONSIBLE ONLY TO THOSE 2 CERTIFIED AND HEREBY DISCLAIMS ANY OTHER LIABILITY AND HEREBY RESTRICTS THE o RIGHTS OF ANY OTHER INDIVIDUAL OR FIRM TO USE THIS SURVEY, WITHOUT EXPRESS CLYDE 0. VAN KLEECK 1114. WRITTEN CONSENT OF THE SURVEYOR. FLORIDA REGISTERED SURVEYOR AND NAPPER NO. 2546 -61 .... NOT VALID WITHOUT THE SIGNATURE 6 THE ORIGINAL RAISED 0 SEAL OF A FLORIDA LICENSED SURVEYOR 101 MAPPER. x i.C.M. FOUND CONCRETE MDMAENT C.M. -CONCRETE NOM,MENT SEC SECTION ONE -OVEREAD ELECTRIC FV -FIRE HYDRANT .LR.C. FOAM IRON ROD AND CAP P.C. -PoINT OF CY TMP IP MV -WATER VALVE C:L.F:CHAIN LINK FENCE .I.R. FOUND IRON R00 P.C. -PoINT!K CURVATURE ROE FAO -FOUND . . -5000 FENCE .I.P. FOIRO IRON PIPE U.E. -UTITLITY EASEMENT P.O. �OF I�THIN HPE -PLAT C.B. -CHORD BEARING ..) > S.I.R.C. SET IRON ROO AAO CAP D.E. -DRAINAGE EASEMENT A/C AI T ES -ELECTRIC BOX AN -MATER METER F.NSO POLIO NAIL AAO DISK C G G-CIMS G GUTTER NTS M7 CORE.-CONCRETE WP -WOOD POLE IR (N) FIELD MEASUREMENT R/H -RIGHT LF WAY 4' C.L.F.— CO -CABLE BOX LP -LIGHT POLE LC) CALCLLATED IEASUiE1EH7 C/L -CENTERLINE 6' M.F. -/—/—,—.- PEI -PHONE BOX M/H -MANHOLE ?. /I FIELD SURVEY DATE ( FIRST COAST LAND \ PROJECT INFORMATION Ai PLOT PLAN ORDER NO: 29105/29105A Z BOUNDARY 07/24/2018 SURVEYORS, INC. DRAWN BY: KMP FORMBOARD 3161-4 ST JOHNS BLUFF ROAD 5 JACKSONVILLE. FL.32246 REVIEWED BY: HF n FOUNDATION 07/30/2018 PHONE (904) 779-2062 FAX (904) 779-7784 CHECKED BY: VAN ` J \.,ANAL CERTIFICATE NO. LB 8225 WWW.FIRSTCOASTLANDSURVEYING.CON t^_______ ---.1'-7 t 7 K- 1 SL 1\c