810 HIBISCUS ST - SOLAR DRAWINGSA SOLAR PV SYSTEM IMPROVEMENT FOR,* c) RHODES RESIDENCE " m 0 Lu ra za SOLAR IMPROVEMENT CONSTRUCTION DOCUMENTS FOR THE EXISTING RESIDENTIAL GRID SYSTEM VICINITY MAP INDEX SHEET DRAWING NAME CV COVERSHEET SLRI SOLAR SYSTEM EQUIPMENT LOCATION PLAN PVR -SS ROOF ATTACHMENT DETAIL - SOLAR ELECTRIC SLR2 ELECTRICAL 3 -LINE DIAGRAM WITH CALCULATIONS I PROJECT SITE LOCATION FOR SOLAR IMPROVEMENT', -------- APPENDIX -------- ■ HB 1021 NEW PROVISION + LETTER Q CELL 325W MODULE DATA SHEET ENPHASE IQ6+ MICROINVERTER DATA SHEET � 0 oQ�a TIED ELECTRICAL0a�z O�zW I'OclW }arx `W Oma° CC 0 in 0 W W Lu cc a PROJECT: Lu V QZ4o �J6o� go Lu W M Q' N M o �g a PROJECT: HEET as _ OCUME OT to D UT ✓ A - SEAL �� FL E 803 x JUL 19 20T Lu V Z W 0 Lu W M Q' N M LL - 0 O m w Cie ww V ::E o Q N Z 00 m >- Ji V c WN r= W Z Wo J Qa O O V„ Baa o DATE 7/19/2018 �w of DRAWN BY: JJAT §� CHKD BY: JJAT REC. NO. #129127 € j9 SCALE I AS NOTED F. HEET as _ OCUME OT to D UT ✓ A - SEAL �� FL E 803 x JUL 19 20T RESIDENTIAL ROOF LAYOUT - WIND ZONES - PV MODULE LAYOUT AND EQUIPMENT LOCATION PLAN SCALE: N.T.S. MATERIALS REQUIRED: (20) Q CELL 325W MODULE W/ (20) ENPHASE IQ6+ MICROINVERTERS (10) IRONRIDGE MICROINVERTER MOUNTING KITS (NOTE: EACH KIT COMES WITH 2 BOLTS) (8) 17' XR100 RAIL (2) XR100 INTERNAL SPLICE KITS (3) GROUNDING LUGS FOR ARRAY CONNECTIONS OF #6 BARE COPPER (50) WIRE MANAGEMENT CLIPS (38) IRONRIDGE L -FOOT W/ LAG SCREW (12) IRONRIDGE UFO SLEEVES (12) IRONRIDGE END CAPS FOR RAILS (46) IRONRIDGE GROUNDING UFO CLAMPS (20) LANDSCAPE OR PORTRAIT ENPHASE Q CABLE CONNECTORS (2) ENPHASE END CAPS (1) NEMA 3R RATED ROOF MOUNTED JUNCTION BOX DISCLAIMER: MATERIALS REQUIRED LIST FOR CONCEPTUAL USE ONLY THE INTENT IS TO AID CONTRACTOR FOR ORDERING REQUIRED MATERIALS FOR THE PROJECT. CONTRACTOR RESPONSIBLE TO VERIFY PRIOR TO SOLAR EQUIPMENT ORDERING, m a 0 PROJECT: s�j �a �7 w� o� DATE 7/19/2018 DRAWN BY: IAT CHKD BY: JAT REC. NO. #1 29127 SCALE I AS NOTED �. 'EET 2 OF 'i�4 , ROOF LAYOUT NOTE: SOLAR PANEL LAYOUT IS CONCEPTUAL, BUT AS PROVIDED, CONFORMS WITH THE REQUIREMENTS SET IN SHEET PVR -SS FOR SPECIFIED ADDRESS. CONTRACTOR MAY ADJUST PANEL LOCATION, BUT SHALL OMEN T CONFORM TO THE REQUIREMENTS ON SHEET PVR -SS. SOLID AREAS ON CORNERS OF ROOF ARE WIND ZONE 3 AREAS. SIGN EAL rT � FCOR1�5��-'� ETiREY A"i0R79 V JUL 192018 s�j �a �7 w� o� PHOTOVOLTAIC MODULE GENERAL NOTES: 1.APPLICABLE CODE: 2017 FLORIDA RESIDENTIAL CODE (6TH EDITION) & ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES. 2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER 2017 FLORIDA BUILDING CODE (6T EDITION) REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A SOUTHER YELLOW PINE (SYP) RESIDENTIAL WOOD ROOF TRUSS AS EMBEDMENT MATERIAL. 3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIENTIAL ROOFS, CONSIDERING FROM A 7° TO A MAXIMUM 27° (2/12 TO A MAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. EXISTING RESIDENTIAL ROOF SHALL NOT EXCEED 30'-0" MEAN ROOF HEIGHT. 4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511, AND IS THE RESPONSIBILITY OF THE CONTRACTOR TO PILOT FILL ALL HOLES. 5. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO MANUFACTURER MANUAL FOR ALL ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND SOLAR SPECS. 6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESS OTHERWISE NOTI=D. 7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED. B. ALL 39" X 78" PV MODULES MAY BE INSTALLED PER THIS STRUCTURAL CONNECTION DRAWING. 9. ALL SOLAR RAILING AND MODULES SHALL BE INSTALLED PER MANUFACTURER INSTRUCTIONS. 10. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2017 FLORIDA RESIDENTIAL CODE (6TH EDITION) OR LOCAL GOVERNING CODE. ULTIMATE WIND ZONE 1 MAX WIND ZONE 2 MAX WIND ZONE 3 MAX JEMBED JIND SPEED SPAN, MAX SPAN, MAX SPAN, MAX DEPTH V"n(MPH) CANTILEVER CANTILEVER CANTILEVER REQ. 130 I 4' 0" O.C. , V-7" O.C. I 4' 0" O.C. , 1'-7" O.C. I 2'-0" O.C. , 9" O.C. 13" SCHEDULE REFLECTS COMPONENTS AND CLADDING (CBC) NOMINAL WIND PRESSURES WITH EXPOSURE "C", RISK CATEGORY II , ENCLOSED BUILDING AND h < 60'-0" PER ASCE 7-10 "MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES" AND 2017 F.B.C. * LAG BOLT DEPTH REQUIRED IN WOOD MEMBER EXCLUDES ANY ROOF DECKING THICKNESS. a DIMENSION DEFINED PER ASCE 7-10 SHALL BE 4 FT REGARDLESS AS PER 2017 FLORIDA RESIDENTIAL CODE 6TH EDITION r----------- --------------------- i I I GABLE END BUILDING Cl HIP END BUILDING ROOF ROOF WIND AREA ZONES WIND AREA ZONES I , ' --------- 2--- ---2------ /R \PVR TYPICAL PHOTOVOLTAIC -ARRAY PITCHED ROOF LAYOUT - WIND ZONES - SCHEDULE - PLAN 1 SCALE: NONE PVR 39" X 78" PHOTOVOLTAIC MODULE TYP. rwrnIlLi znuvvLCl /METAL 5V ROOF TYP, FOR MAX SPAN REQ. TYPICAL PHOTOVOLTAIC MODULE ARRAY PLAN SCALE:l a"=1 '-0" S.Y.P. 2X4 TRUSSES A 2-16D NAI END TO W OPTIONAL SPANNER CONNECTION DETAILS SCALE: 1 2"=1'-0" 12" ALUMINUM INTERNAL SPLICE BAR (USE WHEN d SPLICE AT MID -SPAN W/ A(4) #10-16X2" ST STL SELF r _ TAPPING SCREWS TYP IRONRIDGE XR1000 OR XR100 #10 16x2" ST STL SELF TAPPING ALUM. SOLAR RAIL TYP SCREW TYP 4 PLCS PER BEAM SPLICE TYPICAL SOLAR RAIL BEAM SPLICE DETAIL SCALE: 1 2"=1'-0" TYP. 2 PLCS. PER SIDE OF MODULE AND BE CONNECTED < 25% OF MODULE LENGTH. USE ANTI -SEIZE AND TIGHTEN TO TORQUE PER MANUF. INSTRUCTIONS REFER TO SCHEDULE FOHEPTH REQUIRED EMBEDMENT LABELED "X" IN THIS DET ALUMINUM L -FOOT TYP EVERY ROOF PENETRATION 8" - 16 HEX CAP ST STL BOLT AND ST STL A SERRATED FLANGE -NUT TYP. SCALE: 1 2'=1'-0" REFER TO SCHEDULE FOR REQUIRED EMBEDMENT DEPTH LABELED "X" IN THIS DETAIL. ALUMINUM L-FOOT- TYP EVERY ROOF PENETRATION 8" - 16 HEX CAP ST STL BOLT AND ST STL SERRATED FLANGE NUT TYP. I%i � A END -CLAMP W/4' - PHOTOVOLTAIC MODULE TYP. =-: ' ,.._ 20 HEX CAP ST STL "" - _ BOLT AND ST STL PHOTOVOLTAIC ASPHALT SERRATED STL BOLT AND (1) ST MODULE TYP. SHINGLES / FLANGE -NUT TYP. IRONRIDGE XR1000 METAL 5V END -CLAMP SIZE OR XR100 ALUM. -= -, , WOOD ROOFING TYP. VARIES. SOLAR RAIL TYP. ';_ __ - SHEATHING ST STL LAG BOLT. SEE FRONT SIDE BEAM SP�Ej WOOD ROOF 16' SCH FOR EMBED DEPTH METAL 5V TRUSS TYP. REQ. TYP EACH L -FOOT TYPICAL PV SOLAR RAIL END CONNECTION DETAIL WOOD ROOF ib" FOR EMBED. DEPTH REQ. TYE SCALE: 1 2'=1'-0" REFER TO SCHEDULE FOR REQUIRED EMBEDMENT DEPTH LABELED "X" IN THIS DETAIL. ALUMINUM L-FOOT- TYP EVERY ROOF PENETRATION 8" - 16 HEX CAP ST STL BOLT AND ST STL SERRATED FLANGE NUT TYP. I%i � A SCALE: 1 2'=1'-0" r 0 PROJECT: C, = w N V o= W� Lu ,n 4 V _ In <n H LL W mM a w N =M r CD o � c, —Z 000J Z = _ lL 'n OC N w<<nLl�v �„z::Eo< g0 <om z< <JvF-�U w E -- <Z wwZ <NzOoog <0 DATE: 7-19.2018 DRAWN BY: I JAT CHKD BY: JAT RECORD #: 1 29127 SCALE: I AS NOTED DRA I \Ilr I //I sill 3oFV a MENi N A '•!�C oR\v?t JUL 19 2018 .3n z gMR e CENTER -CLAMP WITH `- "� - ' �" - 20 HEX CAP ST PHOTOVOLTAIC STL BOLT AND (1) ST MODULE TYP. _ STL SERRATED ` ASPHALT FLANGE NUT TYP. SHINGLES FRONT SIDE BEAM SP�Ej OR XR100 ALUM. SO AR RA ALUM. SOLAR RAIL TYP. METAL 5V LOCATION. SEE TYRZETAIL ..... WOOD ROOFING ST STL LAG BOLT. SEE SCS Ht WOOD ROOF ib" FOR EMBED. DEPTH REQ. TYE SHEATHING TRUSS TYP. EACH L -FOOT TYPICAL PV SOLAR RAIL MID CONNECTION DETAIL SCALE: 1 2'=1'-0" r 0 PROJECT: C, = w N V o= W� Lu ,n 4 V _ In <n H LL W mM a w N =M r CD o � c, —Z 000J Z = _ lL 'n OC N w<<nLl�v �„z::Eo< g0 <om z< <JvF-�U w E -- <Z wwZ <NzOoog <0 DATE: 7-19.2018 DRAWN BY: I JAT CHKD BY: JAT RECORD #: 1 29127 SCALE: I AS NOTED DRA I \Ilr I //I sill 3oFV a MENi N A '•!�C oR\v?t JUL 19 2018 .3n z gMR e POWER TABLE: DC -SIDE A # PV MODULE 1 MANUF Q CELL MODEL Q.PLUS L -G4.2 POWER 325 Wp-dc VOC 46.17 VDC ISC 9.44 A VMP 36.39 VDC IMP 8.85 AMP SYSTEM A EN PHASE DROP CABLE SYSTEM ENPHASE IQ6t = /9 v5 MICROINVERTER TYP. TER TOR CAP LED ON EN OFENPHASEE GA Q ON END OF ENPHASE ENGAGE 3 CABLE SYSTEM ENPHASE 0 CABLE SYSTEM SYSTEM B E f TERMINATOR CAP INSTA ON END OF ENPHASE EI CABLE SYSTEM 1000 NOTE: MAXIMUM OF 13 INVERTERS PER BRANCH CIRCUIT PER MANUFACTURER RECOMMENDATIONS. NEC 2014 LABELING REQUIREMENTS WARNING DEDICATED SOLAR PANEL DO NOT CONNECT ANY LOADS LABEL PER NEC 110.21- PROVIDE AT NEW SUB PANEL OR SERVICE PANEL (IF REQUIRED) WARNING DUAL POWER SOURCE SECOND SOURCE IS PV SYSTEM LABEL PER NEC 705.12(D)(3) & NEC 690.64 - PROVIDE AT MAIN SERVICE PANEL OR TAP BOX LOCATION ENPHASE Q CABLE SYSTEM MAIN PV SYSTEM DISCONNECT PER NEC 690.15 & NEC 690.13(8) - PROVIDE AT MAIN SERVICE PANEL OR NEW SERVICE PANEL FOR SOLAR PV FOR SUPPLY SIDE CONNEd[TION Q CABLE SYSTEM m I NEMA 3R ENCLOSURE CAUTION SOLAR ELECTRIC SYSTEM CONNECTED LABEL PER NEC 690.15 & NEC 690.13(B). PROVIDE AT NEW OR EXISTING SUB PANEL OR SERVICE PANEL PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN LABEL PER NEC 690.56(C) - PROVIDE AT NEW SUB PANEL OR SERVICE PANEL FOR RAPID SHUTDOWN 4J: Z LOBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES i PRIOR TO THE COMMENCEMENT OF WORK LABEL BREAKER PER NEC 690.54, 705.12(D) AND 705.10. 2LEQUIPMENT SYSTEM A SYSTEM B PV BACKFEED CURRENT PLUS MAIN BREAKER RATING MUST BE LESS THAN OR EQUAL TO 120% OF MAIN SERVICE BUS RATING AND BREAKERS MUST BE 07 C 1 ST BRNCH C 2ND BRNC AC -SIDE 1 10 10 INVERTER — COMPLIANT PER NEC 690.12. ENPHASE-IQ6+ 290 W 290OW 290OW PEAK POWER 280 W 280OW 280OW CONT. POWER 240 VAC 240 VAC 240 VAC VOLTAGE 1.17 A 11.7 A 11.7 A CURRENT 60 HZ 60 HZ 60 HZ FREQUENCY EN PHASE DROP CABLE SYSTEM ENPHASE IQ6t = /9 v5 MICROINVERTER TYP. TER TOR CAP LED ON EN OFENPHASEE GA Q ON END OF ENPHASE ENGAGE 3 CABLE SYSTEM ENPHASE 0 CABLE SYSTEM SYSTEM B E f TERMINATOR CAP INSTA ON END OF ENPHASE EI CABLE SYSTEM 1000 NOTE: MAXIMUM OF 13 INVERTERS PER BRANCH CIRCUIT PER MANUFACTURER RECOMMENDATIONS. NEC 2014 LABELING REQUIREMENTS WARNING DEDICATED SOLAR PANEL DO NOT CONNECT ANY LOADS LABEL PER NEC 110.21- PROVIDE AT NEW SUB PANEL OR SERVICE PANEL (IF REQUIRED) WARNING DUAL POWER SOURCE SECOND SOURCE IS PV SYSTEM LABEL PER NEC 705.12(D)(3) & NEC 690.64 - PROVIDE AT MAIN SERVICE PANEL OR TAP BOX LOCATION ENPHASE Q CABLE SYSTEM MAIN PV SYSTEM DISCONNECT PER NEC 690.15 & NEC 690.13(8) - PROVIDE AT MAIN SERVICE PANEL OR NEW SERVICE PANEL FOR SOLAR PV FOR SUPPLY SIDE CONNEd[TION Q CABLE SYSTEM m I NEMA 3R ENCLOSURE CAUTION SOLAR ELECTRIC SYSTEM CONNECTED LABEL PER NEC 690.15 & NEC 690.13(B). PROVIDE AT NEW OR EXISTING SUB PANEL OR SERVICE PANEL PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN LABEL PER NEC 690.56(C) - PROVIDE AT NEW SUB PANEL OR SERVICE PANEL FOR RAPID SHUTDOWN 4J: Z LOBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES i PRIOR TO THE COMMENCEMENT OF WORK LABEL BREAKER PER NEC 690.54, 705.12(D) AND 705.10. 2LEQUIPMENT SHALL BE INSTALLED PER THE 2014 NATIONAL ELECTRICAL CODE (NEC), ALL APPLICABLE OR GOVERNING CODES, MANUFACTURER PV BACKFEED CURRENT PLUS MAIN BREAKER RATING MUST BE LESS THAN OR EQUAL TO 120% OF MAIN SERVICE BUS RATING AND BREAKERS MUST BE REQUIREMENTS OF AND PER THE GOVERNING UTILITY COMPANY. 7 MOUNTED AT OPPOSITE END OF MAIN BREAKER PER NEC 705.12. Z110.3(B). LISTING AGENT NAME AND NUMBER SHALL BE INDICATED PER NEC 110.3(B). ENPHASE MICROINVERTER SYSTEM IS RAPID SHUTDOWN g� ENPHASE Q CABLE SHALL BE KEPT zR ABOVE ROOF SURFACE MINIMUM — COMPLIANT PER NEC 690.12. ATO PREVENT AN INCREASE IN AC VOLTAGE LEVEL AND AVOID ANY NUISANCE FAULTS, IT IS RECOMMENDED TO SIZE CONDUCTOR FOR A ENPHASE Q CABLE SYSTEM DOES NOT CONTAIN A NEUTRAL AND IS NOT REQUIRED PER 9� MANUFACTURER. IQ6+ MICROINVERTER DOES NOT REQUIRE EQUIPMENT BONDING DISTRIBUTION TOTAL VOLTAGE DROP OF 2% OR LESS PER INVERTER MANUFACTURER. FOR GROUNDING. SEE MANUFACTURER'S INSTALLATION MANUAL FOR DETAILS. ALABEL DEVICE PER NEC 690.14(C)(2), AND SECURE PER NEC 690.7(D). C INVERTER OUTPUT CIRCUIT CARLE QOUTDOOR CONDITIONS 4 (4)#10 AWG, INSULATION: THHN/THWN-2 OR SIMILAR (I I #10 AWG, GROUND CONDUCTOR ? CONDUIT MINIMUM INDOOR CONDITIONS 10-2 NM ROMEX CABLE, OF CABLE, OR EQUAL W/ #10 GROUND COMBINER BOX OUTPUT CIRCUIT CABLE OUTDOOR CONDITIONS (3) #10 AWG, INSULATION: THHN/THWN-2 OR SIMILAR (1) #10 AWG, GROUND CONDUCTOR ? CONDUIT MINIMUM CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED LABEL PER NEC 705.12(D)(3-4) & NEC 690.64 PROVIDE AT NEW OR EXISTING SUB PANEL OR SERVICE PANEL WARNING coMPunrvr SYSTEMS. PHOTOVOLTAIC AC DISCONNECT ELECTRIC SHOCK HAZARD. DO NOT TOUCH MAXIMUM AC OPERATING CURRENT: 23.4A TERMINALS. TERMINALS Oj� BOTH THE LINE WARNING MAXI MUM AC OPERATING VOLTAGE: 240V AND LOAD SIDES MAY BEE ERGIZED IN THE INVERTER OUTPUT CONNECTION - DO NOT (PERNEC690.54 PROVIDE AT EXTERNAL AC OPEN POSITI N RELOCATE THIS OVERCURRENT DEVICE DISCONNECT/MAIN SERVICE PANEL/NEW SERVICE PANEL FOR LABEL PER NEC 690.17(E) -PROVIDE AT MAIN SERVICE PANEL LABEL PER NEC 705 -12(0)(2)(36) -PROVIDE AT MAIN SERVICE PANEL SOLAR PV If APPLICABLE) FAI 2OA/2P EXISTING I SOA MAIN SERVICE PANELl L2 CONNECTING 150A/2P TO UTILRY METER (FIELD VERIFTI NEW 60A NON-FUSED DISCONNECT _1 _ (IF REQ BY UTILITY) TO EXISTING NEW 60A GROUNDING RATED ENPHASE ELECTRODE IQ COMBINER BOX SUPPLY SIDE CONNECTION OPTION TO UTILITY GRID 120/240 VAC SINGLE PHASE — OCUMENT TO MAIN BI-DIRECTIONAL DISTRIBUTION (TYP.) UTILITY PANEL WITH MAIN KWH METER BREAKER BOND #B AWG CU TO EXISTING GROUNDING ELECTRODE SUPPLY SIDE CONNECTION COMPLY WITH NEC 705.12(A) DISCONNECT OUTPUT CIRCUIT 131)# 6 AWG, INSULATION: THHN/THWN-2 CONDUIT SIZE "MINIMUM 60 AMP FUSED DISCONNECT. LOCATE 1.11 L21 OUTDOOR AS SHOWN ON SHEET SLRI. SHALL BE SERVICE RATEDG EQUIPMENT 10 COMBINER BOX OUTPUT CIRCUIT (3) # 6 AWG, INSULATION: THHN/THWN-2 (1)# 8 AWG, GROUND CONDUCTOR ' CONDUIT SIZE: J" MINIMUM g7 NEW 60 AMP ENPHASE ENVOY S 20A/2P AC COMBINER BOX 2DA/2P OA/2P SYSTEMA L. -A SYSTEM B - 0 C) m 0 r Q 0 PROJECT: Lu V z 0 V) W t=to to C 4 LL_N 0 Q " ("7 13.� O V N � ce m LL <<w = V W < C) Q V) Z Z-0 m h Rn V N Lu Q W Q Q o€ J N d < Q o gw DATE 7/19/2018 DRAWN BY: I AT CHKD BY: I AT REC. NO. # 29127 SCALE I AS NOTED €w� �GENS •:A. Y61EET — OCUMENT �zo TSIGN Y SEAL •.. JUL 19 2018