Loading...
83 W 9TH ST RES18-0275 `r jJ `' • _ CITY OF ATLANTIC BEACH 4,,,,r.'.„ 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 0109', INSPECTION PHONE LINE 247-5814 RESIDENTIAL - ALTERATION RESIDENTIAL MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: RES18-0275 Description: SGD &Window Replacement Estimated Value: 3326 Issue Date: 9/12/2018 Expiration Date: 3/11/2019 PROPERTY ADDRESS: Address: 83 W 9TH ST RE Number: 170813 0100 PROPERTY OWNER: Name: BANKS DARYL S Address: 83 9TH ST W ATLANTIC BEACH, FL 32233 GENERAL CONTRACTOR INFORMATION: Name: Address: , Phone: Name: JKEELS CONSTRUCTION COMPANY, LLC Address: 5772 RICHMOND RD JACKSONVILLE, FL 32210 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. * A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. i�:L�J: City of Atlantic Beach APPLICATION NUMBER Jr) js� '^ .\`..A Building Department (To be assigned by the Building Department.) .‘ 800 Seminole Road -� 6Z7S -0 Atlantic Beach, Florida 32233-5445 w Phone(904)247-5826 • Fax(904)247-5845 1011 y? E-mail: building-dept@coab.us Date routed: • City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 3 VV 1. 1 �-+ Department review required Yes No � 3." cam/ (ildinApplicant: K EELS 's-1.�j0 - Planning &Zoning WI 5e 11 +tiTree Administrator Project: R.E? LIkCE c�G� . UN i t 6UIU ix v'-,�blic Works rte. Public Utilities Al 81.474 e _Public Safety re, Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: pproved. ❑Denied. ❑Not applicable (Circle one.) Comments: n d 1 VC a►'r1 I r CoCc f1 f yQ/C 10(t- : i �'1 V4slip-470x r n $"1 � cedi`UA BUILDING we '-e )(tot Sv 10r►A , '�-A�1 :r-WC 44`'' s/a:417v g /ACC CA/'•)4-06417. PLANNING & ZONING � f Reviewed by: /n Date: al ^ '7--1 TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: nApproved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 1-(t U to I V L_:a U fit�'"; OFFICE ( Building Permit Application Updated 12/8/17 , City of Atlantic Beach AUG 8 2018 „�� 800 Seminole Road,Atlantic Beach,FL 32233 (� Phone:(904)247-5826 Fax:(904)247-5845 7 Job Address: 6✓ ''I p J Permit NumberB�/ )f( c U�'7d G' Sf Legal Description Io"34.38 'a5—ant• Dell ,QIAN-6c Pic SaccltRE '']`o�j3'1V (CO ' s1K(P"� ?? Valuation of Work(Replacement Cost)$ 4.71 32 , Heated/Cooled SF Non-Heated/Cooled • Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Indow/Door • Use of existing/proposed structure(s)(Circle one): Commercial esidentia • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: I,,� W Ir�(Qw e t� o12. Repf c i-E- ' Z��- \/41101€--- r Teat' Florida Product Approval# See- MlikehMelgr for multiple products use product approval form Property Owner� ('e � Informatio Name: el I I� ) Address: 63 '4 �g , City j(i(Ad4-n-vi c. ismetv State C I Zip fir_ Phone go • o5 1505 E-Mail Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company: e,' - kA ` ' —i._ Qualifying Agent: Address 5r1E6 w- iw 814 Su4-3 City ,‘N.Y. State V.1 Zip ?2.40 Office Phone Qw•-j . R 55 Job Site/Contact Number L•(p3 • 1505 State Certification/Registration# C 15153 )E-Maillf tldtL f aFotik[/[Lt lki/7jt ,404i Architect Name&Phone# n/& d Engineer's Name&Phone# 1)14 Workers Compensation 1/4-Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS, FURNACES, BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY a M r) RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEI u_ o 2 o O OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE E .2 c LL -- p ECORDING 0 R NOTICE OF COMMENCEMENT. < › is e LL 6L U z i d O o: (Signature of Owner or Agent) o i (Signature of Contractor) > .d g g (including contractor) n r a n : w s` Si ned nd sworn to( affirmed)before me thi day of Sig ed d savor . (. affirmed)before me this "I day Ufa '= q O Q LL A A - J I: T x ��,by !�`��Clei 1I1t:. ��� �;�IF a by -3 A P ig3 w 4.= . (Signature of Notary) (Signa of Notary) L -' [ ]Personally Known OR [41<conally Known OR [r1-Pfioduced Identification11 [ ]Produced Identification 7( Type of Identification: t1C_,,) l...LC CType of Identification: I T1 (c S r15 y��/J - ;1)- -J V ,I ___/1 it,\.- V _cl l .� w (z...1 , b0_5N S71 7-'7SO ! . , ' NOTICE OF COMMENCEMENT ,PREPARE IN DUPLICATE) / 43 - G/G` Permit No. Tax Folio No. State of F Le ft..PA County of pts J To whom it may concern: The undersigned hereby informs you that improvements will be made to certain real property,and In accordance with Section 713 of the Florida Statutes,the following information is stated In this NOTICE OF COMMENCEMENT. Legal descnptllop of property being improved: i i `/ 0 o ' O 0 s LB-3I 3 Ya' 0?9E� • OQ/ 4/4rr-/hc. G • '!. K1 I(n 7-S, ea3 Fj Cor (a 4 01 &7 Address of p rty being improved: I Alarm f/ • K tr z1 ,se , F/ o9• -33 4 a General description of improvements: • •�a' . �, �'�e�"L . ����7 f �•�f � elPtelinC — O.vner r; , Address 3 it-,f a57- IL : ?4-.. 2etfrG /3E' , 32.6,13 Owner's interest in site of the improvementL:/G /t --f' Fee Simple Titleholder(if other than owner) r,)/4_. Name Address Contractor Ila ��:>!. ;' �R1-�t:. ' Address 5 VA M _ i1fr� r�'_-__'� Phone No ,., a • ,=• Fax No Surety(if any) /14/', Address Amount of bond$ Phone No. Fax No. Name and address of any person making a loan for the construction of the improvements. Name itl Address Phone No. Fax No. Name of person within the State of Florida.other than himself.designated by owner upon whom notices or other documents may be served. Name Ai Address Phone No Fax No. In addition to himself.owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(21(b).Florida Statutes.(Fill in pt Owner's option). Name it..,r& 1_ ') „•; - Address "-%* 4' Phone No. Fax No. m x < Expiration date of Notice of Commencement(the expiration�te is one(1)year from the date of recording unless a „ A O n different date is specified): a z n a THIS SPACE FOR RECORDER'S USE ONLY I / , OWN R �/� Y < N In QQ 4 O -,.-.. i_ - [a- i i DATE ��V •• d 0 Before this= Gay or wAT=�� - m the n tr is Doc#2018187107,OR BK 1 Countyof Dud t•a of Florida.tis•er • • e,e,n Cj s T Number Pages: 1 8485 Page 1914, ' S • • ' gib*-• —- him .' ��'!• at a • _ :•eC�aratiOrs herein 4 Recorded 08/09'2018 are true and accurate ' 1� RONNIE FUSS 08.54 AM, ^ Q� u COUNTY ELL CLERK CIRCUIT COURT DUVAL " RECORDING $1000 ! „ r C..�1c{' r\--lt/I'‘Hrk--0-'1L Notary Putn)c at Large State O l Y'V'P. 1 My commission expires_ i f{, (• l Personally Kno..n Or, Produced identafication ' FHH E COQ\ EAGLE VIEW WINDOWS w SERIES 8500 VINYL SINGLE HUNG WINDOW INSTALLATION ANCHORAGE DETAILS U w GENERAL NOTES: INSTALLATION NOTES: 0 1 1. PRODUCT ANCHORS SHALL BE AS DESIGNATED AND LOCATED AS SHOWN IN d 1.THIS PRODUCT HAS BEEN TESTED,EVALUATED AND DESIGNED TO THE CURRENT EDITION OF THE FLORIDA BUILDING CODE.TESTING WAS THIS PRODUCT EVALUATION DOCUMENT.ANCHOR EMBEDMENT AND EDGE CONDUCTED IN ACCORDANCE WITH AAMA/WDMA/CSA 101/I.S.2/A4-40-08 AND 11. DISTANCE EXCLUDE WALL FINISHES,INCLUDING BUT NOT LIMITED TO STUCCO, • 2.THE PRODUCT DETAILS CONTAINED HEREIN ARE BASED UPON SIGNED AND SEALED TEST REPORT NO.NCTL-210-4105-02 AND ASSOCIATED FOAM,BRICK VENEER AND SIDING. co LABORATORY DRAWINGS BY NATIONAL CERTIFIED TESTING LABORATORIES. 2. SEE INSTALLATION ANCHOR SCHEDULE ON SHEET 2 FOR TYPE AND GRADE OF i 3.THIS PRODUCT EVALUATION DOCUMENT IS NOT FOR USE IN THE HIGH VELOCITY HURRICANE ZONE(HVHZ). ANCHOR,AND/OR MANUFACTURERS ANCHOR SPECIFICATIONS,INCLUDING w m m MINIMUM NOMINAL SIZE,MINIMUM EMBEDMENT INTO SUBSTRATE AND MINIMUM 3 EDGE DISTANCES. 4.ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY AND 2X FRAMING FRAMING SUBSTRATES AS A MAIN WIND FORCE U 4 RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE 2.1. EDGE DISTANCES SHALL BE MEASURED FROM CENTERLINE OF ANCHOR TO 0 EDGE OF STRUCTURAL SUBSTRATE EITHER TO THE INTERIOR OR EXTERIOR CzC O Ib RESPONSIBILITY OF THE LICENSED PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT ACTING AS THE DESIGN PROFESSIONAL OF OF THE FENESTRATION PRODUCT. > S3 RECORD FOR THE PROJECT OF INSTALLATION. 22. MINIMUM EMBEDMENT SHALL BE BASED ON PENETRATION INTO MAIN WIND O ,c" m L7 5 FORCE RESISTING SYSTEM SUBSTRATE. O i' 5.1X AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE. BUCK 2 iy ia8 DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE LICENSED PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT ACTING AS 3. SEE SHEETS 5 THROUGH 7 FOR SPECIFIC ANCHOR INSTALLATION DETAILS. °�d iT�tn I- THE DESIGN PROFESSIONAL OF RECORD FOR THE PROJECT OF INSTALLATION. p� i Z LOCATIONS 4.ONE(1)INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION *z €$ 8.PROTECTIONWHEN INSTALLED ACCN ORDANCE WITH TIERE(CURRENT EDITION OF NDBORNE DEBRIS PROTECTION ORIDA BUILDING CODEUIREMENTS EUSING AN APPROVED IMPAT,THIS PRODUCT CT PROTECTION S OPENING SHOWN. 2 Q>> O ° DEVICE. S.ANCHOR QUANTITIES AND SPACING/EMBEDMENT AND EDGE DISTANCE x ZQ 5 g iF 5.1. THE NUMBER OF INSTALLATION ANCHORS IS BASED ON THE MAXIMUM END j� 7.SITE CONDITIONS NOT COVERED IN THIS PRODUCT EVALUATION DOCUMENT ARE SUBJECT TO ADDITIONAL ENGINEERING ANALYSIS BY A ;_-o p I DISTANCE RS AND THE MAXIMUM ON CENTER(O.C.)SPACING PLACEMENT rh LICENSED PROFESSIONAL ENGINEER OR REGISTERED ARCHITECT AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. OF ANCHORS IN ACCORDANCE WITH ELEVATIONS ON SHEETS 3 AND 4. I Q Z 6 t,l 5.2. END DISTANCES AND O.C.SPACINGS LESS THAN THAT SHOWN IN THE a 8.WINDOW FRAME MATERIAL:VINYL(PVC). ELEVATIONS ON SHEETS 3 AND 4 ARE ACCEPTABLE. W (Iyy B.GLASS MEETS THE REQUIREMENTS OF ASTM E1300.09e. 5.3. FOR WINDOW SIZES SMALLER THAN THOSE SHOWN,ANCHOR QUANTITIES ,o 5l CAN BE REDUCED WHILE MAINTAINING EDGE DISTANCE AND O.C.SPACING Y Bp 10. DESIGNATIONS X'STANDS FOR OPERABLE LITE/SASH AND'0"STANDS FOR FIXED LITE. REQUIREMENTS. 5.4. ANCHOR QUANTITIES AND SPACINGS SHOWN ARE BASED ON THE LOWER OF it ANCHOR SPACING USED IN TESTING OR REQUIRED BY LOADING AT DESIGN Z 11. THESE DRAWINGS CERTIFY THE WINDOW INSTALLATION ONLY. WATER PROOFING OF THE INSTALLED WINDOW IS NOT PART OF THIS PRESSURE. Lu9E INSTALLATION CERTIFICATION.THAT RESPONSIBILITY SHALL BE THAT OF THE MANUFACTURER AND/OR THE INSTALLER. 5.5 SEE EMBEDMENT AND EDGE DISTANCE DESCRIPTION ON SHEET 2. 8. MAXIMUM ALLOWABLE SHIM THICKNESS IS 1/4 INCH.SHIM WHERE SPACE OF 1/18 INCH OR GREATER OCCURS. SHIM(S)SHALL BE CONSTRUCTED OF WOOD COMPOSITE,HIGH DENSITY PLASTIC OR SIMILAR LOAD BEARING MATERIAL. 7. FOR CONCRETE BLOCK APPLICATIONS DO NOT INSTALL INSTALLATION TABLE OF CONTENTS ANCHORS INTO MORTAR JOINTS. SHEET SHEET DESCRIPTION 8. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR 1 GENERAL NOTES,INSTALLATION NOTES,TABLE OF CONTENTS MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BERobert Aw;P e USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH Flame RE.No 48752 2 ANCHOR SCHEDULE-EMBEDMENT AND EDGE DISTANCE SPECIFIED IN THE INSTALLATION ANCHOR SCHEDULE ON SHEET 2. 3 53'x 83'WINDOW ELEVATION/NAILING FIN(FIN FRAME)ANCHORING LAYOUT Digitally 4 53'x 63'WINDOW ELEVATIOWTHROUGH FRAME ANCHORING LAYOUTsigned by PERFORMANCE RATING �;Amp.v" Robert) 5 NAILING FIN(FIN FRAME)INSTALLATION e�e,•2aw2,�cl, GLAZING DETAIL Pd�`''•' ,o:: MAXIMUM WINDOW SIZE DESIGN PRESSURE(PSF) IMPACT RATING = " ^•_ _A mo ru so 6 THROUGH FRAME INSTALLATION W/FLANGE (SEE SHEET 8) �I 7 THROUGH FRAME INSTALLATIONNONE I,.$o'••. W Date: 8 GLAZING DETAILS AND BILL OF MATERIALS(80M) NOMINAL 53'x 83' A *I-�` SEE NOTE 6 :8y:'�.^.:O.YO a': g ;;.. 2018.05.03 15:04:41 -04'00' t INSTALLATION ANCHOR SCHEDULE PAIN INSTALLATION FASTENER HEAD FASTENER MANUFACTURER AND/OR NTN.EDGE MIN.SPACING(IN) a SECTION VIEW SUBSTRATE EMBEDMENT BETWEEN FRAME ANCHOR CAPACITIES BASED ON TYPE TYPE SLZE SPECIFICATION (�) DISTANCE(IN) ANCHORS CONCRETE ITW TAPCONS(1) 1 1-1/8 3 MIN.2500 PSI CONCRETE I- U HEX HEAD 3/16" WW STRENGTH CONFORMANCE TO THROUGH SECTION A B&C MASONRY(BLOCK/CMU) ITW TAPCONS(1) 1 2 3 3 ASTM C-90,MEDIUM WEIGHT FRAME ANCHOR (SHEETS 7) ANSI B18.6.1 (WOOD SCREW)(2) PAN HEAD No.10 WOOD GRADE 2 EQUIVALENT 1-3/8 3/4 2 1/2 WOOD WITH A MINIMUM ASME 818.6.4(TAPPING SCREW)(2) SPECIFIC GRAVITY OF 0.42. • r GRADE 2 EQUIVALENT CONCRETE ITW TAPCONS(1) 1 1-1/8 3 MIN.2500 PSI CONCRETE w o '° o HEX HEAD 3/16" STRENGTH CONFORMANCE TO 2 gX U SNAP-ON MASONRY(BLOCK/CMU) ITW TAPCONS(1) 1 2 3 igl t a FLANGE WITH SECTION A,B&C ASTM C-90,MEDIUM WEIGHT 2S THROUGH (SHEETS6) ANSI 818.6.1 (WOOD SCREW)(2) Ia r 6 FRAME ANCHOR GRADE 2 EQUIVALENT WOOD WITH A MINIMUM < L� a PAN HEAD No.10 WOOD ASME B18.6.4(TAPPING SCREW)(2) 1-3/8 3/4 2 1/2 SPECIFIC GRAVITY OF 0.42. o Z GRADE 2 EQUIVALENT _ 1 i1.B ANSI 818.6.1(WOOD SCREW)(3) V R e & AW k1 F NAILING FIN SECTION A, GRADE 2 EQUIVALENT WOOD WITH A MINIMUM 7rn(Cj d = PAN HEAD No.8 WOOD ASME 818.6.4(TAPPING SCREW)(3) 1-5/8 1/4 1 LLL ANCHOR (SHEETS 5) SPECIFIC GRAVITY OF 0.42. i i Z GRADE 2 EQUIVALENT w 4111NOTES:1)WHEN ITW TAPCONS ARE USED FOR CONCRETE/MASONRY INSTALLATION,THEY SHALL BE THE ADVANCED THREADFORM TECHNOLOGY TYPE. S — o 2)FOR WOOD SCREW INSTALLATION INTO WOOD SUBSTRATE;IF SPUTTING IS A CONCERN,DRILL 0.090"PILOT HOLE(DRILL SIZE 43).FOR TAPPING SCREW INSTALLATION INTO WOOD SUBSTRATE;IF SPLITTING IS A CONCERN,DRILL i (!)r 0.121"PILOT HOLE(DRILL SIZE 31). hDC�Si t�iS M 3)FOR WOOD OR TAPPING SCREW INSTALLATION INTO WOOD SUBSTRATE;IF SPUTTING ISA CONCERN,DRILL 0.082"PILOT HOLE(DRILL SIZE 45). 4i 11 2X WOOD FRAMING. SEE 161IliANCHOR SCHEDULE ON TAN EMBEDMENT SHEET 2 FOR DISTANCE DISTANCE 1 SUBSTRATE VARIES. SEE .-V I EDGE J SUBSTRATE VARIES. SEE REQUIREMENTS. ANCHOR SCHEDULE ON5. DISTANCE I ANCHOR SCHEDULE ON SHEET 2 FOR • .. , i I ,.•:..•., �� REQUIREMENTS.SHEET 2 FOR "fir,+ ,""' REQUIREMENTS. / EDGE DISTANCE / -us% A / EMBEDMENT ::`'.`.rt`83t., ' _:� EMBEDMENT 1�rli./ A EDGE DISTANCE / JAI RW�t J.Ammo,PE f ` AM I I';. •-� Flald•P.E Na 4W52 a INSTALLATION ANCHOR. SEE ANCHOR I `l SCHEDULE ON SHEET 2 FOR it `a?"•......^ao REQUIREMENTS INCLUDING SIZE. TYPE, INSTALLATION ANCHOR. SEEPP ` f�t�°9`,.a"t , I ANCHOR SCHEDULE ON SHEET 2 INSTALLATION ANCHOR. SEE ANCHOR ,�: EMBEDMENT AND EDGE DISTANCE. i FOR REQUIREMENTS INCLUDING SCHEDULE ON SHEET 2 FOR Lt.'4'f a` ,. SIZE, TYPE. EMBEDMENT AND REQUIREMENTS INCLUDING SIZE, TYPE. :o.. s,• o..:�: EDGE DISTANCE. „ EMBEDMENT AND EDGE DISTANCE. siF'<o . ,•' 'SSn�o,ON.IENode... EMBEDMENT AND EDGE DISTANCE EMBEDMENT AND EDGE DISTANCE EMBEDMENT AND EDGE DISTANCE Digitally signed by NAILING PIN PRAMS INSTALLATION THROUGH-PRAMS INSTALLATION SNAP-ON FLANGE 7NROUGH-PRAMS INSTALLATION Robert J Amoruso Date:2018.05.03 15:04:54-04'00' b NAILING FIN INSTALLATION ANCHOR SHOWN. SEE ANCHOR SCHEDULE ON s 3' MAX• (TYP.) e SHEET 2. ' MAX. (r P.)-+y� '..._ 7 3/4' O.C. SPACING, Zr. + +/-1'TOL •) DENOTES FIN FRAME ANCHOR LOCATION U \ • • • a • . sr e • 1 0 ee2.1 • o 2 r5 O.C. SPACING • b-1 " 7' +/-1' TOL. (TYP.) .D 3 N 2 • • 1/4" XED LTTE •5 a =7{ ad WIDTH D.LO. w F3N t • • t< W Nil • ,�„,� 47.325' SASH _� • �tlb• WIDTH D.LO. .E:1 I/ 4' O.C. SPACING CENTERED I"!� 1 ABOUT MEETING/LOCK RAIL • •CENTERLINE =o +1' TOL (TYP.) (TYP.) o 113 0 N 1 i i t 1/X 1 MAX. OW.) • • /1 j jJ • • a • • • •� T • 50 1/2" RWort J.Airmail.P 2i' MAX. MP.)_F--- MAX. SASH WIDTH — Florida P.E.No.1Y752 53 1/8' Digitally MAX. FRAME WIDTH signed by .SERIES 8500 VINYL SINGLE HUNG WINDOW - 35 PSF DESIGN PRESSURE "°•""""' �E�.;�.��,'��k. Robert J "'i Amoruso EXTERIOR VIEW o.,Date: 53"X 63"NOMINAL SIZE -GLAZING DETAIL A 1°.:,: .a,,o.:`:•' NAILING FINE(FIN FRAME)ANCHOR INSTALLATION ,S: E"°'` 2018.05.03 15:05:11 -04'00' L 15' O.C. SPACING, THROUGH—FRAME INSTALLATION +/-i' TOL (TYP.) l e® ANCHOR SHOWN. SEE ANCHOR A 4' MAX. � I •) SCHEDULE ON SHEET 2. -V V 1- ''' ►ANC ENOTES LOCATION FRAME 3 PO e / , sr 12 1/2' 0.C. SPACING, z� 3 +/-1' TOL. (T P.) r u2 rt 3 } 48 1 4' FIXED LRE !illW y DTH D.LO. gg I ....0 ate. x a i a' r z 1§11 47.325 SASH EA WIDTH D.LO. —� _�u Ni 8' O.C. SPACING L rz_ 4i DG CENTERED ABOUTr� MEET1NG/LOCK RAIL NTERLINE vex p i 13. +/- 2E TOL (TYP.) •• Q G1 o •• ; 94413 v PO nA kit••ANCHORS NEAR h o MEETING RAIL SHALL IR BE N. 41 t LOCATED AS REQUIRED , _ t TO FACILITATE • INSTALLATION. 4' MAX. (TYP.) } (- A A ,SILL ANCHORS TO BE - _ _ INSTALLED USING REM NO. .30 SILL CLIP. SEE -No 50 1/2• SECTION A SHEETS 5, 8 PSE FlorldeMAX. SASH WIDTH AND 7 FOR DETAILS. Digitally 53 1/8' signed by MAX. FRAME WIDTH """""'w Robert J Q} EM 4,7.„ SERIES 8500 VINYL SINGLE HUNG WINDOW - 35 PSF DESIGN PRESSURE „...,,,,,...,,..,,,,....pe, ' ' ` Amoruso EXTERIOR VIEW '�. `Lf, o, :a=Date: 53"X 63"NOMINAL SE -GLAZING DETAIL A • 3s...,aN r• IZ2018.05.03 THROUGH-FRAME ANCHOR INSTALLATION 15:05:22 -04'00' Li SEALANT BETWEEN FIN2X WOOD FRAMING. SEE AND 2X WOOD 2X WOOD FRAMING. SEE ANCHOR SCHEDULE ON a FRAMING BY OTHERS •• r • ANCHOR SCHEDULE ON SHEET 2 FOR EXTERIOR FINISH SHEET 2 FOR REQUIREMENTS. i REQUIREMENTS. BY OTHERS A INSTALLATION ANCHOR. SEE r ANCHOR SCHEDULE ON SHEET 2 PERIMETER .��- \ FOR REQUIREMENTS INCLUDING w SEALANT BY ` SIZE, TYPE, EMBEDMENT AND a OTHERS 1/4" MAX. EDGE DISTANCE. a IIEl SHIM 1/4" MAX. SHIM 044 INSTALLATION ANCHOR. 0 INTERIOR SEE ANCHOR SCHEDULE ^a� O ON SHEET 2 FOR 1 REQUIREMENTS INCLUDING SIZE, TYPE, EMBEDMENT a o AND EDGE DISTANCE. Liki O Z f O EXTERIOR FINISH . . . g rr iP a gg .� 1414NMI ® BY OTHERS ;- "'{�N■ MI o m 1 � SEALANT BETWEEN FIN ��tl�w�a ila AND 2X WOOD EXTERIOR 80'_441 ® ! ;r,mna ® FRAMING BY OTHERS 0 0- ; PERIMETER g Z Ee N o Al SEALANT BY i IXED LITE HORIZOINTAL 1 N sZ 1i SCREEN O 'i i 0 OTHERS CROSS SECTION i s Orli NAILING FIN FRAME INSTALLATION EXTERIOR INTERIOR 2X WOOD FRAMING. SEE �'� a ANCHOR SCHEDULE ON Z SHEET 2 FOR INSTALLATION ANCHOR. SEE !O REQUIREMENTS. ANCHOR SCHEDULE ON Lill! SHEET 2 FOR l= REQUIREMENTS INCLUDING SCREEN 0 �� © ` SIZE,NDTYPE, EMBEDMENT :_, AND EDGE DISTANCE. PERIMETER © __1 r 1/4" MAX. 1/4" MAX. SHIM +I SHIM , r O SEALANT BY I 0 INTERIOR OTHERS `��� SEALANT BETWEEN FIN4.-N`� \ 2X WOOD FRAMING. SEE AND 2X WOOD ANCHOR SCHEDULE ON ` I� Ur!il FRAMING BY OTHERS SHEET 2 FOR 1 ' �.na �wPe REQUIREMENTS. �� Florida P.E No.40752 EXTERIORFINISH :"• EXTERIOR FINISH • �7 Digitally BY BY OTHERS {•:: �' CI . l�EI signed by l "g4.^, INSTALLATION ANCHOR. SEE ANCHOR SCHEDULE SEALANT BETWEEN FIN ��: ; e�.�, Robert J ON SHEET 2 FOR REQUIREMENTS INCLUDING AND 2X WOOD ' `= SIZE, TYPE, EMBEDMENT AND EDGE DISTANCE. FRAMING BY OTHERS SCREEN Amoroso EXTERIOR '"= Date: PERIMETER °VERTICAL CROSS SECTION A',;�`so",ev+.•'„;64.ct„°0F 2018.05.03 NAILING FIN FRAME INSTALLATION SEALANT BY /NO ASH LITE HORIZONTAL OTHERS 15:05:33 CROSS SECTION -04,00, NAILING FIN FRAME INSTALLATION SUBSTRATE VARIES. SEE SUBSTRATE VARIES. SEE I ANCHOR SCHEDULE ON ANCHOR SCHEDULE ON EXTERIOR FINISHSHEET 2 FOR SHEET 2 FOR BY OTHERS REQUIREMENTS. REQUIREMENTS. cQi A / INSTAl1ATI0N ANCHOR. INSTALLATION ANCHOR. SEE �i / ONE SHEET 2 FORCHOR ANCHOR SCHEDULE ON SHEET 2 1- ! PERIMETER ' / + REQUIREMENTS FOR REQUIREMENTS INCLUDING o La SEALANT BY l—_ i INCLUDING SIZE, TYPE, `� SIZE, TYPE, EMBEDMENT AND OTHERS ® -- r / } EMBEDMENT AND EDGE ' EDGE DISTANCE. X SHIMS J DISTANCE. . a 1/4" MAX. SHIM �2 , 0 INTERIOR ; / (ol SEALANT SEALANT BETWEEN �`JJ BETWEEN FRAME AND SUBSTRATE FRAME AND BY OTHERS ` m m 0i 0 SUBSTRATE `I, 3 o BY OTHERS \�" 0 g tg o m O EXTERIOR FlNISH kI y r m BY OTHERS ";"i€S: s:'.,; ' €i]i] ] I ! u)a a fi OLT L' - �lt� z 1 ® M ® PERIMETER • EXTERIOR 8 W O D�;;.;.1 , ti SEALANTOTHBY3 i !1 7 i O B FIXED LITE HORIZONTAL S 3d Y gLi i SCREEN 0 ��� 6 CROSS SECTION R.42`` folo THROUGH-FRAME INSTALLATION EXTERIOR INTERIOR SUBSTRATE VARIES. SEE SNAP-ON FLANGE ANCHOR SCHEDULE ON � )� O SHEET 2 FOR INSTALLATION ANCHOR. SEE ANCHOR SCHEDULE � g '�'D 0 REQUIREMENTS. , SIZEN S TYPE,HEET 2FOR EMBEDM NT ANDENTS DGENDISTANCE.ING ` e � SCREEN "�—J= SEALANT BETWEEN FRAME AND �_ _ SUBSTRATE BY OTHERS v © I 0 1/4" MAX. SEALANT BETWEEN Al 1/4" MAX. SHIM �� FRAME AND ® 1 _ ( SHIM SUBSTRATE BY . 1,‘ �' O INTERIOR . ��• OTHERS _ PERIMETER ,:,.,,.,, �F r SUBSTRATE VARIES. SEE SEALANT BY , , ANCHOR SCHEDULE ON ``I OTHERS '' / SHEET 2 FOR REQUIREMENTS. \"�� Di'1 EXTERIOR FINISH EXTERIOR FINISH :.:...:...:.,:.: A BY OTHERS BY OTHERS Pnb�IJ.Moun.P.E • FbrlOa P.E.No.19752 \\ I' m �.I�� 0 Digitally •• INSTALLATION ANCHOR. SEE ANCHOR SCHEDULE . signed by ON SHEET 2 FOR REQUIREMENTS INCLUDING ✓�" `t Robert J SIZE, TYPE, EMBEDMENT AND EDGE DISTANCE. PERIMETER ® SCREEN ""�wO+off Z�'''` .• SEALANT HERS EXTERIOR �, ,"R u '�Amoruso OVERTICAL CROSS SECTION ‘1,-....r." =Date: THROUGH-FRAME INSTALLATION 0 S A S H LITE HORIZONTAL 9s`°^=°'`°?+' SNAP-ON FLANGE *.�In„i,`�'' 2018.05.03 CROSS SECTION 15:05:44 THROUGH-FRAME INSTALLATION SNAP-ON FLANGE -04'00' SUBSTRATE VARIES. SEE t. ANCHOR SCHEDULE ON SUBSTRATE VARIES. SEEv ANCHOR SCHEDULE ON REEU2 FOR a SHEET 2 FOR REQUIREMENTS. REQUIREMENTS. INSTALLATION ANCHOR. SEE ANCHOR SCHEDULE Zr EXTERIOR " " ' ON SHEET 2 FOR REQUIREMENTS INCLUDING 7k FINISH BY TYPE, EMBEDMENT AND EDGE DISTANCE. OTHERS / 1/4" MAX. SHIM W Ii i •� ` , INTERIOR PERIMETER 1/4" MAX.I SST \` Q SEALANT BY r SHIM OTHERS FRAMEWMID �(� ' INSTALLATION ANCHOR. OVERS �\_II o I SEE ANCHOR SCHEDULEBY i i m �I ` O (2� ON SHEET 2 FOR 0 g '7 REQUIREMENTS I — § FS a INCLUDING SIZE, TYPE, O EMBEDMENT AND EDGE blh _ Ilit &i i5 a i DISTANCE. EXTERIOR FINISH —� m *a"I ® � SEALANT BETWEEN BY OTHERS EXTERIOR b a FRAME AND -�•'�=� SUBSTRATE . � � � � © ' 11=m BY DTHERs sPEAUMN BYR FIXED LITE HORIZOINTAiilgE L 1� ® OTHERS e CROSS SECTION = iM 0 u 1.,: :fy; s i I THROUGH-FRAME INSTALLATION r4 1 II SCREEN 0 O 6 t1 1 INSTALLATION ANCHOR. SEE ANCHOR SCHEDULE ,!aEa EXTERIOR INTERIOR ON SHEET 2 FOR REQUIREMENTS INCLUDING i6 SUBSTRATE VARIES. SEE SIZE, TYPE, EMBEDMENT AND EDGE DISTANCE. kill ANCHOR SCHEDULE ON O ��I SHET 2 FOR REQUIREMENTS. 1/4" MAX. SHIM SCREEN 0 � �' ` 0 0 INTERIOR �,� � \ PERIMETER © I , 1/4" MAX. SEALANT BETWEEN FRAME �, �\'� SEALANT BY I F SHIM AND SUBSTRATE BY OTHERS ''� �r! OTHERS _��mils � SEALANT � , SUBSTRATE VARIES. SEE ILI1111" , 1031041 J.Mo sP.E. BETWEEN FRAME ANCHOR SCHEDULE ON ` 0 AND f3Y OTHERS SHEET 2 FOR , ,iMEs'",,, • REQUIREMENTS. OQ ieNgF��q EXTERIOR FINISH ` BY OTHERS a JEXTERIOR EXTERIOR --,F '1,0,;" FINISH FINISH BY • ... PERIMETER ss;os.o"iE"° INSTALLATION ANCHOR. SEE ANCHOR SCHEDULE OTHERS ON SHEET 2 FOR REQUIREMENTS INCLUDING SEALANT BY AA BBY v SASH LITE HORIZONTAL Digitally signed by SIZE, TYPE, EMBEDMENT AND EDGE DISTANCE. ilir CROSS SECTION Robert 1 Amoruso 1VERTICAL CROSS SECTION THROUGH-FRAME INSTALLATION Date:2018.05.03 THROUGH-FRAME INSTALLATION 15:05:56-04'00' BILL OF MATERIALS 8500 SERIES SH BOM NO. PART NO. DESCRIPTION REMARKS 1 7867 JAMB PVC Qi 3 2 7868 HEAD PVC m� 3 7869 SILL PVC a 4 7863 VENT STILE PVC i- x on © 5 7866 VENT RAIL PVC wII 6 7864 FIXED INTERLOCK PVC E8 1/2" GLASS BITE g 7 7865 VENT INTERLOCK PVC a MP t FIXED UTE 8 6177 GLAZING BEAD PVC SHOWN AT HEAD. 9 STGBLK SETTING BLOCK NOT SHOWN 3/4" OVERLL THICKNESS IGU: LOCK RAIL AND 10 7871 SCREEN LOCK OPTIONAL 1/8" ANNEALED x DURALITE SPACER x JAMBS SIMILAR. 1/8" ANNEALED ® HARDWARE a 12 m 12 9208 BASE NOT SHOWN g a If 13 9202 LEVER NOT SHOWN z GLAZING DETAIL A 14 SHLK CAM it< '0 a 15 SHLKKPR KEEPER 2I dry°L2g 16 677204 CAM LOCK(OPTIONAL) USED IN DP50TEST ,4 a;3=aa ,,i I 17 677133 KEEPER(OPTIONAL) USED IN DP50 TEST 4 a i 3/4" OVERLL THICKNESS IGU: 18 110-5/MRBLCK MEETING RAIL BLOCK Apply 7864 to 7988 T-Bar 22 ltilJ 1 i 1/8" ANNEALED x DURALITE SPACER x WEATHERSTRIPPNG z~>5 w 1/8" ANNEALED ��zz EF9 19 1 WEATHERSTRIP .187x.270FIN PILE ;cc y Sc �� GLAZING S cg 8— Aii 20A FOAM TAPE BACK-BEDDING 5,co c U til ® 1/2" GLASS BETE 208 SILICONE — ,3- S� 0 ,..— C -- 21 GLAZINGDETAILA 3/4"OVERLLTHICKNESS IGU x �I�I I REINFORCEMENT �� , �� I © 22 RNFCHK FIXED REINFORCEMENT ALUMINUM 6063-T5 �� i 23 RNFVNT VENT REINFORCEMENT ALUMINUM 6063-TS I SASH UTE SHOWN © AT SILL. MEETING BALANCE AND TILT COMPONENTS RAIL AND JAMBS SIMILAR. 25 700 SERIES BALANCE(CONSTANTFORCE) NOT SHOWN 26 728 PIVOT LOCK SHOE(1.292"x.562") NOT SHOWN GLAZING DETAIL A 27 275 PIVOT BAR NOT SHOWN 28 9637 ANCHOR NOT SHOWN 29 76800/76900 TILT LATCH ASSEMBLY NOT SHOWN INSTALLATION COMPONENTSR.b.nJ. u.o PE NOTES: 30 6384 SILL CLIP PVC Acrid.P.E No.4a752 1. A MINIMUM OF TWO(2)NEOPRENE SETTING BLOCKS WITH 31 8864 I SNAP-ON FLANGE 1 PVC Digitally 70 TO 90 SHORE A DUROMETER HARDNESS ARE REQUIRED AT BOTTOM(SILL)OF GLAZING LITES MORE signed by THAN 3 FEET IN WIDTH. .+�t.,. "% Robert J flrfin �,�iw�r• s 2. AS-TESTED IGU SYSTEM SHOWN.SUBSTITUTIONS ARE Amoruso ALLOWED IN ACCORDANCE WITH AAMA/VVDMA/CSA 101/I.S. �•,;=�ti a i;W=Date: 2/A440-11,SECTIONS 10.2.3.2 AND 10.2.3.4.SEE SHEET 1 "<$N tvo.,� 2018.05.03 FOR DETAILS RELATED TO WINDOW SIZE/GLAZING "' DETAIL/DESIGN PRESSURE. 15:06:09 -04'00' . - t I N Customer Confirmation Live Order -C Page 1 Our Order# 19,077 13340 International Parkway Order Type Retrofit `> Eala6/07/2018 -,,$ gPhone Jacksonville,904-6131200 Ship2218 Fax Date Date 6/28/2018 WINDOWS&DOORS Fax 904-527-8287 Dealer 1286 Ship Phone 904-465-1505 Truck — Bill To: — Job Name Madeline Banks 83 West 9th Street 83 W 9th Street 83 West 9th Street Atlantic Beach, FL 32233 Atlantic Beach, FL 32233 PO#: Rep TN Qty Description Color Width Height Unit Cost Net Line 1 1 Single Hung Equal Sash White 23 1/2 58 1/2 Argon White Boxed White H Flange White HP Low-E Bottom LI HP Low-E Top Single Lock White U-Factor=0.30/VT=0.42/SHGC=0.22 DP=+/-35/FL ID=26572.1 Line 2 1 Single Hung Equal Sash White 23 1/2 58 1/2 Argon White Boxed White H Flange White HP Low-E Bottom HP Low-E Top Single Lock White U-Factor=0.30/VT=0.42/SHGC=0.22 DP=+1-35/FL ID=26572.1 Line 3 1 Single Hung Equal Sash White 47 1/2 58 1/2 Argon White Boxed White 1-_I Double Lock White Flange White HP Low-E Bottom HP Low-E Top U-Factor=0.30/VT=0.42/SHGC=0.22 DP=+/-35/FL ID=26572.1 Line 4 1 Horizontal Slider XO White 71 5/8 17 1/4 Argon White Boxed White Flange White HP Low-E Left HP Low-E Right IILl Single Lock White U-Factor=0.29/VT=0.42/SHGC=0.22 DP=+/-30/FL ID=27085.1 Line 5 1 Horizontal Slider OX White 71 5/8 17 1/4 TW WS01CON -48 Printed: 8/01/2018 @ 7:42:13AM 0 Office Our Order# 19,077 Customer Confirmation Live Order Page 2 Madeline Banks Qty Description Color Width Height Unit Cost Net Argon White Boxed White Flange White HP Low-E Left HP Low-E Right Single Lock White J U-Factor=0.29/VT=0.42/SHGC=0.22 DP=+/-30/FL ID=27085.1 Line 6 1 Horizontal Slider OX White 71 5/8 58 3/4 Argon White Boxed White Double Lock White Flange White 1 HP Low-E Left HP Low-E Right - , Oversized White U-Factor=0.29/VT=0.42/SHGC=0.22 DP=+/-30/FL ID=27085.1 Line 7 1 Single Hung-Screen Equal Sash White 23 1/2 58 1/2 Screen White ■I Addtl Ship Line for Line#1 Line 8 1 Single Hung-Screen Equal Sash White 231/2 58 1/2 Screen White Li Addtl Ship Line for Line#2 Line 9 1 Single Hung-Screen Equal Sash White 47 1/2 58 1/2 Screen White Addtl Ship Line for Line#3 Line 10 1 Horizontal Slider XO-Screen White 71 5/8 17 1/4 Screen White Addtl Ship Line for Line#4 Line 11 1 Horizontal Slider OX-Screen White 71 5/8 17 1/4 TW WS01CON -48 Printed: 8/01/2018 @ 7:42:13AM 0 Office Our Order# 19,077 Customer Confirmation Live Order Page 3 Madeline Banks Qty Description Color Width Height Unit Cost Net Screen White Addtl Ship Line for Line#5 Line 12 1 Horizontal Slider OX-Screen White 71 5/8 58 3/4 Screen White Addtl Ship Line for Line#6 Line 13 1 Window Installation Material -Included White 0 Even 0 Even Windows on Order= 6 Even RF-Boxed White Other Charges 6.0 Window Installation 1.0 Measure Fee-Denny IMPORTANT -- PLEASE READ Material Confirmation of order received. Tax Your order will be built as specified on this confirmation. Installation Any changes to this confirmation must be made within 24 hours (excluding rushes). Freight Manufactured items are non-returnable, non-cancelable and non-refundable. Deposit THANK YOU- WE APPRECIATE YOUR BUSINESS! Grand Total STUCCO TW WS01CON -48 Printed: 8/01/2018 @ 7:42:13AM 0 Office ET —1,,, e''t"� nares Rep: 5)/ /li(�.W"____ Date: 0S4(i 1 r Customer: /11 4pa LT.✓vF An>icr f 11. 1ECIEOVIE* Street Address: QJ T-µ j��(o�fQ '? !d City: ATLGt C g��-CU State: F L Zip Code: 3cL135 • CCL Phone: 90 V- - ki- 6S- /50,c Phone: Phone: Phone: y Lj 0 Color Window In W j --1 s S+vcc U Color Window Out (�/[-/ 1A4aile✓wicr-6111-AuIeith Opening Size Frosted Rough Opening Make Size No. Style Room Glass Grids Mull W x H St's T B WxH WxH . �� x (j0 0FFscC x 23%z x..:`3 +/), isN . x 6 o or6c6 x -43 % 6— Y . 5 . d,t1- x 60 o�c4 L}- 0)-45 5 7aL x 17 IGT H 05 . x ` 7// x .x / 7 Lrc- os o 56 x ' ,-/ 5/.� x 17Y6 LSE's 7ok x 6 o grC bX x 3 x x x xx x x x . x x x x x x x x x x x x x x x x xx x x x x . • x x x x x x xx x x x x 6 TOTAL WINDOWS TOTAL DOORS Customer Signature Date 1 • PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA Project Name: / tcl eiiiul arts Permit # Project Address: 8 u) qT 6 AtUtiviic, eifith Ft S2133 As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: www.floridabuilding.or& Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# A.EXTERIOR DOORS 1. Swinging 2. Sliding 3. Sectional , 4.Roll up 5.Automatic 6. Other B.WINDOWS , 1.Single hung 7, r r m 7,i i•'• SbD ,� - X43 4i/51a.I 2.Horizontal slider 1 1� ata - a1Z$ ZTOtS / 3. Casement 4.Double hung 5. Fixed 6.Awning 7. Pass-through 8. Projected 9.Mullion 10.Wind breaker 11.Dual action f 12. Other Category/Subcategory I Manufacturer [Product Description iLimitation of Use State# Local# , C.PANEL WALL 1. Siding 2. Soffits 3. EIFS 4. Storefronts 5. Curtain walls 6.Wall louvers 7.Glass block 8. Membrane 9.Greenhouse _ 10. Synthetic stucco 11. Other D. ROOFING PRODUCTS 1.Asphalt shingles 2. Underlayments 3. Roofing fasteners 4.Nonstructural metal roof 5. Built-up roofing 6. Modified bitumen 7. Single ply roofing o- 8. Roofing tiles 9. Roofing insulation 10.Waterproofing 11.Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coats 15. Roof tile adhesive 16. Spray applied polyurethane roof 17. Other Category/Subcategory Manufacturer Product Description imitation of Use State# Local# E. SHUTTERS ` 1. Accordion 2. Bahama 3. Storm panels 4. Colonial 5. Roll-up 6. Equipment 7. Other F.STRUCTURAL COMPONENTS 1.Wood connector/anchor 2.Truss plates 3. Engineered lumber 4. Railing 5. Coolers-freezers 6. Concrete admixtures 7. Material 8. Insulation forms 9. Plastics 10. Deck-roof 11.Wall 12. Sheds 13. Other G. SKYLIGHTS 1. Skylight 2. Other • Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# H. NEW EXTERIOR ENVELOPE PRODUCTS 1. 2. In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. (Contractor Name) (Print Name) (Signature) Company Name: T, e e-/ Li '/2S ze/w " Mailing Address: 5-911- / /34.1 .C"/vd 6l!• 3 ✓ae.r so/, c" k 3 22/4) City: State: Zip Code: Telephone Number:(0,V) e 'at 'r Fax Number: ( ) Cell Phone Number: ( ) E-mail Address: