Loading...
2400 SEMINOLE RES17-0088CITY OF ATLANTIC BEACH 800 Seminole Road Atlantic Beach, Florida 32233 REVISION REQUEST / CORRECTIONS TO PLAN REVIEW COMMENTS Date Revision to Issued Permit Corrections to Comments Permit # /7 . DO 8e Project Address '-� I00 few "on d(i, Contractor / Contact Name A r 1,7 / Phone_ ¢0 y— a S—�'I, y/ Description of Proposed Revision / Corrections: cc - Additional Increase in Building Value $ /-:z- Email -L Email f,N V fl Irl'! h -le leo �4,, Permit Fee Due i So -,OZ) S1 Additional S.F. By signing below, I (printed name) affirm the Revision is inclusive of the proposed changes. Signature of Contractor/Agent (Contractor must sign if increase in valuation) Date Approved Revision/Plan Review Comments Department Review Required: C Building �> Planning & Zoning Tree Administrator Public Works Public Utilities Public Safety Fire Services (Office Use Only) Denied Not Applicable to Department 'yp rob COPY LR Pq-7 4'L eviewed By 2C)/ Date DESIGN SPECIFICATIONS DESIGN CODE: 2017 FLORIDA BUILDING CODE RESIDENTIAL DESIGN IS VOID ONE YEAR AFTER THE DATE OF THE ORIGINAL PLANS, UNLESS PLANS HAVE BEEN REVIEWED FOR CODE COMPLIANCE. DESIGN LOADS: ACTUAL AND UNIFORM MATERIAL SPECIFICATIONS HARDWARE AND ANCHORS: ANCHOR BOLTS & THREADED ROD: SHALL BE IN ACCORDANCE WITH ASTM A 307 OR ASTM F 1554 GRADE 36. WASHERS: SHALL BE IN ACCORDANCE WITH ASTM A500 (GRADE B). NUTS: SHALL BE IN ACCORDANCE WITH ASTM A 563 GRADE A HEX. METAL CONNECTORS: ALL METAL CONNECTORS WHICH ARE EXPOSED TO EXTERIOR SHALL BE GALVANIZED. RETROFIT REBAR/ROD INSTALLATION: EMBEDMENT OF RODS OR REBAR DOWE S SHALL BE 12 BAR DIAMETER MINIMUM, HOLES SHALL BE 1/4" LARGER THAN REBAR SIX AND '/$" LARGER THAN THREADED ROD SIZE. (U.O.N.) ANCHORING ADHESIVE: SHALL BE ONE OF THE FOLLOWING PRODUCTS (DUAL CARTRIDGE INSTALLATION ONLY): EPDXY: I TW RED HEAD A7 REINFORCING STEEL: SHALL BE ASTM A615, GRADE 60. STRUCTURAL STEEL: SHALL BE ASTM A992, GRADE 50. WELDED WIRE FABRIC (WWF): SHALL BE ASTM A185. SCOPE OF SERVICE MEANS AND METHODS: THE STRUCTURAL ENGINEER SHALL NOT HAVE CONTROL OR BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES, OR SEQUENCES; FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR OR ANY OTHER PERSONS PERFORMING THE WORK OR FOR THE FAILURE FOR ANY OF THEM 10 CONSTRUCT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. LIMITS OF STRUCTURAL ENGINEERING DESIGN RESPONSIBILITIES: THE ITEMS SPECIFICALLY DESIGNED BY THE STRUCTURAL ENGINEER ARE LIMI ED TO THE FOLLOWING: NEW STEEL SUPPORT POSTS, FOUNDATION AT STORAGE ROOM AND CONNECTIONS AT EL VATOR OPENING. ITEMS NOT DESIGNED: ANY ARCHITECTURAL, MECHANICAL OR ELECTRICAL SYSTEM. GENERAL NOTES & CONSTRUCTION SPECIFICATION MASONRY SPECIFICATIONS: MASONRY HAS BEEN DESIGNED IN ACCORDANCE WITH ACI 530-05, AND SHALL BE CONSTRUCTED IN ACCORDANCE WITH AC1530.1-05. GROUT SHALL BE IN ACCORDANCE WITH ASTM C476 WITH A MINI UM OF 28 DAY COMPRESSIVE STRENGTH OF 2000 psi PER ASTM C1019, GROUT SHALL HAVE A MAXIMUM COURSE AGGR GATE SIZE OF 3/8 PLACED AT AN 8" TO 11" SLUMP. MORTAR SHALL CONFORM TO ASTM C270 AND TYPE M OR S. TYPE N VIORTAR MAY BE USED IN BRICK VENEER. CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND INSTALLATION OF ALL FLASHING. CONCRETE MASONRY UNITS (CMU): CMU SHALL BE IN ACCORDANCE WITH ASTM C90-75, HOLLOW LOAD—BEARING CMU), TYPE 1, GRADE N-1, NORMAL WEIGHT, WITH A MINIMUM COMPRESSIVE STRENGTH OF 1900 psi (f'm=1500 psi) GROUT f,LL CELLS CONTAINING VERTICAL REINFORCEMENT IN 5'-0" MAXIMUM LIFTS PROVIDE CLEANOUTS PER ACI 530.1-02 IN THE BOTTOM OF COURSE OF MASONRY WHEN THE WALL HEIGHT EXCEEDS 5'-0". MASONRY STEMWALLS: ALL CONCRETE MASONRY UNITS SHALL BE COMPOSED CF ASTM C90E, E GRADE N-1 HOLLOW CONCRETE MASONRY UNITS WITH TYPE 'S' MORTAR. WALL COURSING SHALL BE RUNNING BONDS, STACK BOND SHALL NOT BE USED. GROUT ALL CELLS CONTAINING VERTICAL REINFORCEMENT WITH 3000 PSI PEA ROCK CONCRETE GROUT. SPLICES IN REINFORCING, WHERE PERMITTED, SHALL BE 48 BAR DIAMETERS. ALL EXTERIOR WALLS SHALL BE REINFORCED FULL HEIGHT WITH — #4 @ 4'-0" O.C. MAX. AND AT EACH CORNER, WALL END, ANQ WALL INTERSECTIONS. PROVIDE CONTINUITY OF REINFORCING AT INTERSECTIONS OF PERPENDICULAR MASONRY ELEMENTS BY INSTALLING CORNER BARS, MINIMUM OF 40.BAR DIAMETERS INTO EACH ELEMENT. AT STEMWALL CONSTRUCTED OF 5 OF MORE COURSES, PROVIDE HORIZONTAL JOINT REINFORCEMENT AT 16" O.C. VERTICALLY, (EVERY OTHER COURSE), AND VERTICAL REINF. SHALL BE INCREASED AS NOTED ON 1/S1.0. UNLESS NOTED OTHERWISE. LAP JOINT REINFORCING SHALL BE A MINIMUM OF 6". CONCRETE SPECIFICATIONS: ALL CONCRETE HAS BEEN DESIGNED IN ACCORDANCE WITH ACI 318-08, AND HALL BE CONSTRUCTED IN ACCORDANCE WITH ACI 301. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGT OF 2500 PSI AT 28 DAYS CONCRETE AT GARAGE AND PORCH SLABS SHALL HAVE A COMPRESSIVE STRENGTH OF 3000 1 PSI. FOOTING AND FOUNDATIONS: FOOTINGS AND FOUNDATIONS SHALL BE IN ACCORDANCE WITH LOCAL BUILDING CODES. FOOTING HAVE BEEN DESIGNED WITH A SOIL BEARING (DESIGN MAXIMUM) OF 2000 PSF. A SOILS INVESTIGATIOM REPORT IS RECOMMENDED TO VERIFY SUITABLE SUBSURFACE CONDITIONS. IF THE FOOTING ELEVATIONS SHOWN OCCU IN A DISTURBED OR UNSTABLE SOIL, THE ENGINEER SHALL BE NOTIFIED. SOIL SHALL BE FREE OF ORGANIC MATERIAL AND COHESIVE (CLAY) SOILS. SOIL COMPACTION AND FILL SHALL BE COMPACTED TO A MIN. OF 95% MODIFIED PROCTOR IN AC ORDANCE WITH ASTM D 1557. FOUNDATION PLAN ONLY CONVEYS STRUCTURAL INFORMATION. FOR GENERAL FEATURES, CONDUITS, ELECTRICAL EMBEDS, STEP HEIGHTS, ETC., SEE ARCHITECTURAL PLANS. DO NOT SCALE FOOTING DIM NSIONS AND LOCATION FROM THE FOUNDATION PLAN SHOWN ON S1.0. DO NOT DETERMINE FOOTING LOCATION BASED ON EITHER THE ARCHITECTURAL PLAN OR FRAMING PLAN, BUT BY DIMENSIONS PROVIDED ON FOUNDATION PLAN. IFFOOTING SIZE OR LOCATION IS NOT DETERMINED ON PLAN THEN CONTACT ENGINEER OF RECORD (EOR) UNLESS OTHERWISE NOTED ON DRAWINGS, MINIMUM CONCRETE COVER FOR REI FORCING SHALL BE 3" IN FOOTINGS AND MESH SHALL BE CENTERED IN SLAB ON GRADE. IN ALL CONTINUOUS FOOTINGS PROVIDE #3 @ 48" O.C. OR ROD CHAIRS. PROVIDE CONTINUITY OF REINFORCING AT INTERSECTIONS OF PERPENDICULAR CONCRETE ELEMENTS BY INSTALLING CORNER BARS, MINIMUM OF 40 BAR DIAMETERS INTO EACH ELEMENT. SPLICES IN REINFORCING, WHERE PERMITTED, SHALL BE 48 BAR DIAMETERS CONCRETE SLABS ON GRADE: SHALL BE INSTALLED OVER MINIMUM 6 MIL POLYETHYLENE VAPOR RETARDER WITH JOINTS LAPPED 6" AND SEALED OVER CLEAN, COMPACTED EARTH OR FILL WITH APPROVED CHEMICAL SOIL TREATMENT FOR PREVENTION OF SUBTERRANEAN TERMITES. SAWCUTS: FOR CONTROLLED CRACKING CUT A 1" SAWCUT INTO SLA3 IN A 12'x12' GRID WITHIN 12 HOURS OF CONCRETE PLACEMENT, PROVIDE SAWCUTS THROUGH OUT SLAB CALL EOR FOR ALTERNATIVE METHODS. WATERPROOFING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN/INSTALLATION OF LL WATER PROOFING. PRE—ENGINEERED MISCELLANEOUS STRUCTURES: ANY EYEBROW, CANOPY, ALUMINUM COMPONENT OR ANY OTHER BUILDING APP NDAGES NOT SPECIFICALLY DETAILED HEREIN SHALL BE DESIGNED BY OTHERS AT THE EXPENSE OF THE CONTRACTOR. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF MISCELLANEOUS ATTACHED STRUCTURES TO THE MAIN STRUCTU E INDICATING CONNECTION POINTS, REACTIONS AND FASTENER REQUIREMENTS PRIOR TO FABRICATION OF MISCELLANEOUS STRUCTURE AND PRIOR TO CONSTRUCTION OF MAIN STRUCTURE. CONTRACTOR SHALL COORDINATE LOADING REQUIREMENTS WITH ANY OTHER PRE—ENGINEERED COMPONENT SUCH AS ROOF FLOOR AND ROOF TRUSS ENGIN ERING. STRUCTURAL STEEL DETAIL, FABRICATE, AND ERECT ALL STRUCTURAL STEEL IN ACCORDANCE WITH AISC SPECIFICATION FOR DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS. ALL STRUCTURAL STEEL WORK SHALL CONFORM TO THE AISC SPECIFICATION FDR STRUCTURAL STEEL FOR BUILDING — ALLOWABLE STRESS DESIGN AND PLASTIC DESIGN, 14TH EDITION. PRIME: ALL STEEL SURFACES, BOTH EXPOSED AND CONCEALED ARE TO RECE VE ONE SHOP COAT OF PAINT AND FIELD SPOT PRIME ALL WELDS, SCARS CONN., ETC., WHERE PAINT IS DAMAGED. EXISTING WALL FRAMING TO REMAIN #5 'Z' BAR 1—#5 CONT. LTJ LIJ U) 8" CMU STEMWALL w/#4 @ 32" O.C. VERTICAL OR 8" C.I.P. CONC. WALL w/#4 @ 16" O.C. VERTICAL AND HORIZONTAL SLAB ON GRADE, SEE PLAN. 1'-0' w/(2)#4 CONT. �#3 @ 48" O.C. OR ROD CHAIRS (TYP.) 3 1 FOUNDATION DETAIL AT STEP S1.0 / SCALE: 3/4" = 1'-0" EXISTING CONC. BEAM CAP PLATE, SEE SECTION AT RIGHT SLAB ON GRADE 4 1 CD d I I 44 I I � I 4; o 2,-6" Y"O x 8 2 " TITEN HD. (3)#4 EA. WAY BOT. STEEL POST DETAIL SCALE: 3/4" = 1'-0" OPENING CUT INTO SLAB FOR ELF VATOR CAP PLATE, SEE SECTION AT LEFT 1i» CAP & BASE. PLATE DETAIL Y"0 x 8" TITEN HD. STEEL POST DETAIL SCALE: 3/4" = 1'—O" EXISTING WALL FRAMING TO REMAIN #5 'Z' BAR 4 III -1 I I=1 11-1 I I- 11== =1 I I®III-1 I -f I I-1 I I-1 I �1 -III-III-III_ 11-I I I_I I , III_ I -111-1 I I=1 I I=1 1-1 I I S 11= I I I ���III��,II III (IIIIIIfIIIIIii��-1111��1{i OVERHEAD EPDXY APPLICATION: USING AMBEX ANCHORING CAPSULES DRILL & EPDXY 1"0 THREADED ROD INTO BOTT. OF EXISTING BEAMS w/6" EMBEDMENT (IN STRIC ACCORDANCE w/MANUF. RECOMMEN ATIONS) STEEL POST PER PLAN Y2" 0 x 8" 8" TITEN HD. 2 5„ BASE PLATE, — SEE SECTION AT RIGHT 4 O 0 O O ® 001■ ■ ti LiM 1—#5 CONT. LTJ LIJ U) 8" CMU STEMWALL w/#4 @ 32" O.C. VERTICAL OR 8" C.I.P. CONC. WALL w/#4 @ 16" O.C. VERTICAL AND HORIZONTAL SLAB ON GRADE, SEE PLAN. 1'-0' w/(2)#4 CONT. �#3 @ 48" O.C. OR ROD CHAIRS (TYP.) 3 1 FOUNDATION DETAIL AT STEP S1.0 / SCALE: 3/4" = 1'-0" EXISTING CONC. BEAM CAP PLATE, SEE SECTION AT RIGHT SLAB ON GRADE 4 1 CD d I I 44 I I � I 4; o 2,-6" Y"O x 8 2 " TITEN HD. (3)#4 EA. WAY BOT. STEEL POST DETAIL SCALE: 3/4" = 1'-0" OPENING CUT INTO SLAB FOR ELF VATOR CAP PLATE, SEE SECTION AT LEFT 1i» CAP & BASE. PLATE DETAIL Y"0 x 8" TITEN HD. STEEL POST DETAIL SCALE: 3/4" = 1'—O" EXISTING WALL FRAMING TO REMAIN #5 'Z' BAR 4 III -1 I I=1 11-1 I I- 11== =1 I I®III-1 I -f I I-1 I I-1 I �1 -III-III-III_ 11-I I I_I I , III_ I -111-1 I I=1 I I=1 1-1 I I S 11= I I I ���III��,II III (IIIIIIfIIIIIii��-1111��1{i OVERHEAD EPDXY APPLICATION: USING AMBEX ANCHORING CAPSULES DRILL & EPDXY 1"0 THREADED ROD INTO BOTT. OF EXISTING BEAMS w/6" EMBEDMENT (IN STRIC ACCORDANCE w/MANUF. RECOMMEN ATIONS) STEEL POST PER PLAN Y2" 0 x 8" 8" TITEN HD. 2 5„ BASE PLATE, — SEE SECTION AT RIGHT 4 BASE PLATE DETAIL EXISTING CONC. OVERHEAD EPDXY APPLICATION: USING AMBEX ANCHORING CAPSULES DRILL & EPDXY 1"0 THREADED ROD INTO BOTT. OF EXISTING BEAMS w/6" EMBEDMENT (IN STRICT ACCORDANCE w/MANUF. RECOMMENDATIONS) STEEL BRACE POST PER PLAN EXISTING CONC. SLAB 1—#5 CONT. OFFICE C REVIEWED FOR CODE COMPLIANCE CITY OF ATLANTIC BEACH SEE PERMITS FOR ADDITIONAL REQUIREMENTS AND CONDITIONS ammon la'n1DATt7,1-12-3 �/ �S V 4 _ 8" CMU STEMWALL w/#4 @ 32" O.C. VERTICAL OR 8" C.I.P. CONC. WALL Q w/#4 @ 16" O.C. VERTICAL LLJ w AND HORIZONTAL Cn -SLAB ON GRADE, SEE PLAN. EXP. JOINT 4#3 @ 48" O.C. OR 4 L 4 ROD CHAIRS (TYP.) 10"x20" w/(3)#4 Lou Pontigo and Associates, Inc. 420 Osceola Avenue Jax. Beach, Florida 32250 Ph. 242-0908 Fax. 241-9557 FL: CA # 8344 SC: CA# 3579 ,' A:. Po \_\C ENST�C No• 3 O �i OF *_ N -RFs < .. R I D �'• ' < Luis A. Pontigo, PE FL PE#53311 REVISIONS DATE FIELD ALTERATION CONTRACTOR SHALL CONTACT LOU PONTIGO 8 ASSOCIATES PRIOR TO MAKING ANY STRUCTURAL FIELD MODIFICATIONS WHICH MAY VARY FROM THE INTENT OF THE ORIGINAL CONSTRUCTION DOCUMENTS ANY FIELD ALTERNATIONS MADE PRIOR TO BEING APPROVED BY LOU PONTIGO h ASSOCIATES MAY RESULT IN ADDITIONAL ENGINEERING OR INSPECTION FEES. BUILDING PLAN DO NOT SCALE DIMENSIONS FROM THESE DRAWINGS, IF A DIMENSION IS UNCLEAR REFER TO THE ARCHITECTURAL DRAWINGS OR CONTACT'rHE E.O.R. PLAN NAME RESIDENCE DESIGN/DRAWN/CHECKED CS / WAC /LAP DATE 06.20.18 SCALE AS NOTED LPA No. SLEI-17-00608 CONTROL No SHFFT 51.0 SHEET 1 OF � O 0 O O BASE PLATE DETAIL EXISTING CONC. OVERHEAD EPDXY APPLICATION: USING AMBEX ANCHORING CAPSULES DRILL & EPDXY 1"0 THREADED ROD INTO BOTT. OF EXISTING BEAMS w/6" EMBEDMENT (IN STRICT ACCORDANCE w/MANUF. RECOMMENDATIONS) STEEL BRACE POST PER PLAN EXISTING CONC. SLAB 1—#5 CONT. OFFICE C REVIEWED FOR CODE COMPLIANCE CITY OF ATLANTIC BEACH SEE PERMITS FOR ADDITIONAL REQUIREMENTS AND CONDITIONS ammon la'n1DATt7,1-12-3 �/ �S V 4 _ 8" CMU STEMWALL w/#4 @ 32" O.C. VERTICAL OR 8" C.I.P. CONC. WALL Q w/#4 @ 16" O.C. VERTICAL LLJ w AND HORIZONTAL Cn -SLAB ON GRADE, SEE PLAN. EXP. JOINT 4#3 @ 48" O.C. OR 4 L 4 ROD CHAIRS (TYP.) 10"x20" w/(3)#4 Lou Pontigo and Associates, Inc. 420 Osceola Avenue Jax. Beach, Florida 32250 Ph. 242-0908 Fax. 241-9557 FL: CA # 8344 SC: CA# 3579 ,' A:. Po \_\C ENST�C No• 3 O �i OF *_ N -RFs < .. R I D �'• ' < Luis A. Pontigo, PE FL PE#53311 REVISIONS DATE FIELD ALTERATION CONTRACTOR SHALL CONTACT LOU PONTIGO 8 ASSOCIATES PRIOR TO MAKING ANY STRUCTURAL FIELD MODIFICATIONS WHICH MAY VARY FROM THE INTENT OF THE ORIGINAL CONSTRUCTION DOCUMENTS ANY FIELD ALTERNATIONS MADE PRIOR TO BEING APPROVED BY LOU PONTIGO h ASSOCIATES MAY RESULT IN ADDITIONAL ENGINEERING OR INSPECTION FEES. BUILDING PLAN DO NOT SCALE DIMENSIONS FROM THESE DRAWINGS, IF A DIMENSION IS UNCLEAR REFER TO THE ARCHITECTURAL DRAWINGS OR CONTACT'rHE E.O.R. PLAN NAME RESIDENCE DESIGN/DRAWN/CHECKED CS / WAC /LAP DATE 06.20.18 SCALE AS NOTED LPA No. SLEI-17-00608 CONTROL No SHFFT 51.0 SHEET 1 OF �