890 SEMINOLE RD - TRUSS REDO DRAWINGSGENERAL NOTES S0.01 S1.01 EPDXY NOTES 1. CODES USED: 2017 FLORIDA BUILDING CODE, RESIDENTIAL EDITION AND EX STING BUILDING 1. ANCHOR BOLTS, REINFORCING STEEL, THREADED RODS, STAIR', HANDRAILS, AND OTHER EDITION, ACI, NDS, APA AND ASCE7-10. 130 MPH EMBEDDED STEEL ITEMS SHALL BE SET INTO HARDENED CONCRETE WITH EPDXY OR EPDXY C CEILING: GROUT ONLY WHERE DETAILED ON THE DRAWINGS OR WHERE APPROVED BY THE ENGINEER. 2. THE ALTERATIONS FOUND WITHIN THESE PLANS ARE DESIGNATED LEVEL 2 kLTERATIONS IN LIVE LOAD: COMPLIANCE WITH SECTION 301.1.2 OF THE EXISTING BUILDING CODE. INTERIOR PRESSURE 2. MANUFACTURER'S DATA FOR ALL EPDXY AND EPDXY GROUT SHALL BE SUBMITTED TO THE LIVE LOAD -STORAGE: 30.0 PSF ENGINEER FOR APPROVAL PRIOR TO INSTALLATION. ACCEPTABLE EPDXY PRODUCTS ARE: 3. ALL DESIGN, CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE ITH APPLICABLE 5.0 PSF CODES AND AUTHORITIES HAVING JURISDICTION OVER THE WORK. HILTI HY150, HILTI HSE2421, SIMPSON STRONG -TIE SET OR APPROVED EQUAL. 4. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS AT THE JOB SITE PRIOR TO IN USING THE ABOVE PRODUCTS, FOLLOW STRICTLY THE MANUFACTURER'S SPECIFICATIONS COMMENCING CONSTRUCTION. w AND DIRECTIONS FOR MIXING AND APPLICATION. HEED ALL LABEL WARNINGS. INSTALL IN m LIVE LOAD: ACCORDANCE WITH APPLICABLE SAFETY LAWS. 5. DETAILS FOUND WITHIN THESE DRAWINGS SHALL BE ASSUMED TO BE TYPIC L DETAILS FOR i THIS JOB ONLY. DETAILS SHALL GOVERN CONSTRUCTION FOR THIS JOB UNLESS NOTED 3. ALL EPDXY AND EPDXY GROUT SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH OF 8,000 OTHERWISE ON THE PLANS. Z PSI AND TENSILE STRENGTH OF 2,300 PSI. 6. SUBSURFACE SOIL CONDITIONS WERE NOT AVAILABLE AT THE TIME OF TF IS DESIGN. THE 4. ALL HOLES SHALL BE DRILLED WITH A DIAMETER NO LARGER THAN 1/8" GREATER THAN THE OWNER SHALL PROVIDE TO THE CONTRACTOR A REPORT OF THE SUBSURFACE CONDITIONS. DIAMETER OF THE STEEL MEMBER BEING INSTALLED. SOIL PREPARATIONS NOTED IN SAID REPORT SHALL BE FOLLOWED UNLESS MORE STRINGENT Q DESIGN IS SPECIFIED WITHIN THESE PLANS. DESIGN OF THIS STRUCTURE AS PERFORMED 5. ALL HOLES SHALL BE CLEANED WITH COMPRESSED AIR AND SHALL BE DRY PRIOR TO ASSUMING 2500 PSF SOIL CAPACITY. w INSTALLATION OF EPDXY. HOLES SHALL BE FREE OF ALL DELET RIOUS MATERIAL SUCH AS U U) LAITANCE, DUST, DIRT, AND OIL. 7. THE SCOPE OF WORK OF THIS PROJECT IS LIMITED TO THE CHANGES SHOWN ON THESE PLANS, F T~ THE SCOPE OF WORK SPECIFICALLY EXCLUDES ANY AND ALL ARCHITECTURAL, 6. CONTRACTOR PERFORMING EPDXY WORK SHALL BE AN APPROVED CONTRACTOR BY THE WATERPROOFING, MECHANICAL, PLUMBING OR ELECTRICAL WORK. MANUFACTURER FURNISHING THE EPDXY MATERIALS, AND SHALU HAVE NO LESS THAN FIVE m YEARS EXPERIENCE IN THE VARIOUS TYPES OF EPDXY RELATED WORK REQUIRED IN THIS 8. EXISTING STRUCTURES ARE SHOWN ON DRAWINGS FOR CLARITY ONLY. VERIFY ALL PROJECT. A NOTARIZED CERTIFICATION FROM THE MANUFACTURER ATTESTING TO THE EXISTING/NEW ELEVATIONS AND TYPE OF CONSTRUCTION OF THOSE STRUCTURES, AND TRAINING SHALL BE SUBMITTED TO THE ENGINEER/ARCHITECT ALONG WITH THE PROPOSAL TO NOTIFY ENGINEER IMMEDIATELY BEFORE BEGINNING NEW CONSTRU TION OF ANY DO THE WORK. INTERFERENCES AND/OR DISCREPANCIES THAT MIGHT EXIST BETWEEN CONSTRUCTION DOCUMENTS AND/OR ACTUAL FIELD CONDITIONS. THE CONTRACTOR SHALL PROVIDE ALL SHEATHING NOTES TEMPORARY BRACING/SHORING, TEMPORARY SUPPORTS AND OTHER SUCH 1 EMS OR OTHER ❑ MEASURES NECESSARY TO PROTECT THE STRUCTURE AND ANY PERSONNEL DURING FOR WALL SHEATHING: CONSTRUCTION. THE DESIGN ADEQUACY AND SAFETY OF ABOVE ITEMS ARE THE SOLE 1. FOR STUCCO AND STONE: MIN ?" OSB OR PLYWOOD, SPAN RATING 32/16, INSTALLED RESPONSIBILITY OF THE CONTRACTOR. VERTICALLY, OR MIN 16" OSB OR PLYWOOD, SPAN RATING 32/16, INSTALLED HORIZONTALLY, TO CONCRETE N WALL FRAMING. FASTEN WITH 8d NAILS AT 6" O.C. ON EDGE, 12" O.C. IN FIELD. 2. FOR ALL OTHER VENEER: MIN 16" OSB OR PLYWOOD, SPAN RATING 24/16, INSTALLED 1. ALL REINFORCED CONCRETE WORK SHALL BE IN CONFORMANCE WITH ACI 318, LATEST VERTICALLY OR HORIZONTALLY, TO WALL FRAMING. FASTEN WITH 8d NAILS AT 6" O.C. ON EDGE, EDITION, "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE", AND ACI 301, LATEST 12" O.C. IN FIELD (BLOCKED PANEL EDGES) OR 6" O.C. EDGE AND FIELD (UNBLOCKED PANEL EDITION, "SPECIFICATIONS FOR STRUCTURAL CONCRETE". EDGES). 2. ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE, (145 PCF +/-) ALL CEMENT SHALL 3. FOR CURVED WALLS: TWO (2) LAYERS OF 4" PLYWOOD. FASTEN WITH 10d NAILS AT 6" O.C. ON EDGE AND 12" O.0 IN FIELD. OUTER LAYER OF PLYWOOD PANEL EDGES MUST BE LAPPED 24" CONFORM TO ASTM C150, TYPE 1. MAXIMUM AGGREGATE SIZE SHALL BE Yz" INCHES FOR MIN WITH INNER LAYER. SHIM FRAMING AS NEEDED FOR TIGHT FIT. FOUNDATIONS, AND Y4" FOR ALL SLABS AND SHALL CONFORM TO ASTM C33. FOR ROOF SHEATHING: 3. MINIMUM CONCRETE COMPRESSIVE STRENGTH OF ALL CONCRETE IS 3000 PSI AT 28 DAYS. 1. FOR SHINGLE AND METAL ROOF: MIN OSB OR PLYWOOD, SPAN RATING 24/16, INSTALLED 4. 4" 3000PSI CONCRETE SLAB WITH 6X6 W1.4 X W1.4 WWM OR 1/2" FIBERMESH OVER A 6 MIL. 16" PERPENDICULAR TO ROOF FRAMING. FASTEN WITH 8d NAILS AT 6 O.C. ON EDGE, 12" O.C. IN VAPOR BARRIER AND TERMITE TREATED SOIL. FIELD. 2. FOR TILE ROOF: MIN �" PLYWOOD, SPAN RATING 32/16, INSTALLED PERPENDICULAR TO ROOF 5. THE FILL BELOW THE FOUNDATION SHOULD BE FREE OF DEBRIS, ORG NIC MATERIAL, FRAMING. FASTEN WITH 8d NAILS AT 6" O.C. ON EDGE, 12" O.C. IN FIELD. COHESIVE SOILS OR ANY OTHER DELETERIOUS MATERIAL. SOIL MUST BE CON PACTED TO 95% 3. SINGLE CLIP PANEL EDGES. INSTALL PANELS CONTINUOUS OVER TWO OR MORE SPANS WITH MODIFIED PROCTOR MAXIMUM DRY DENSITY FOR TWO FEET BELOW THE E OTTOM OF THE STAGGERED END JOINTS. WHERE PANELS ARE INSTALLED OVER SINGLE SPANS DUE TO FIELD FOOTING. CONDITIONS, BLOCK PANELS AT 12" O.C. 6. ALL REINFORCEMENT SHALL BE GRADE 40 DEFORMED BARS CONFORMING TO ASTM -A615. ALL FOR FLOOR DECKING: CONCRETE REINFORCEMENT SHALL BE FABRICATED, INSTALLED, SUPPORTED AND SPACED IN 1. MIN 4" T&G OSB OR PLYWOOD, SPAN RATING 48/24, INSTALLED F�ERPENDICULAR TO FLOOR FORMS AND SECURED IN PLACE IN ACCORDANCE WITH ACI 315, "DETAILS AND DETAILING OF FRAMING. FASTEN WITH 8d NAILS AT 6" O.C. ON EDGE, 12" O.C. IN FIEIIIII.D. CONCRETE REINFORCEMENT". 2. USE OF APA RATED STURD-I-FLOOR IS ALLOWED WITH A MINIMUM SPAN RATING OF 48/24 AND MINIMUM J" THICKNESS. 7. CONTRACTOR SHALL VERIFY DIMENSIONS AND LOCATIONS OF ALL SLOTS, PIP SLEEVES, ETC., AS REQUIRED FOR MECHANICAL TRADES BEFORE CONCRETE IS PLACED. FOR PORCH CEILING SHEATHING: 1. MIN 8" OSB OR PLYWOOD, SPAN RATING 24/0, INSTALLED PERPENDICULAR TO CEILING FRAMING. 8. VERTICAL AND HORIZONTAL REINFORCEMENT WILL BE LAPPED FOR 36 BAR DIAMETERS OR 24", FASTEN WITH 8d NAILS AT 3" O.C. ON EDGE, 12" O.C. IN FIELD. WHICHEVER IS GREATER. 9. CORNER REINFORCEMENT SHALL BE LAPPED 25". MASONRY NOTES 10. REINFORCEMENT SHALL HAVE THE FOLLOWING COVER REQUIREMENTS; 1. ALL MASONRY WORK SHALL BE IN CONFORMANCE WITH THE LATEST EDITION OF "BUILDING 10.1. 3" FOR CONCRETE CAST AND PERMANENTLY EXPOSED TO EARTH CODE REQUIREMENTS FOR MASONRY STRUCTURES" (ACI 530) AND THE "SPECIFICATIONS FOR 10.2. 2" FOR CONCRETE EXPOSED TO EARTH AND WEATHER MASONRY STRUCTURES" (ACI 530.1) OF THE AMERICAN CONCRETE INSTITUTE. 10.3. 1 1/2" FOR CONCRETE NOT EXPOSED TO WEATHER OR EARTH FOR THE PRI ARY REINFORCEMENT. 2. CONCRETE MASONRY UNITS SHALL BE NORMAL WEIGHT WITH MIN. NET COMPRESSIVE STRENGTH OF 1500 PSI, HOLLOW, LOAD-BEARING UNITS. CONFORMI G TO ASTM C90, TYPE N -II 11. ONLY DIMENSIONS FOUND ON THE FOUNDATION PLAN BY ALEXANDER GRACE CONSULTING, INC., SHOULD BE USED FOR FOUNDATION CONSTRUCTION. IF DIMENSIONS CAN NOT BE 3. MORTAR SHALL CONFORM TO ASTM C270, TYPE M OR S. ALL PORTLAND CEMENT SHALL DETERMINED FROM FOUNDATION PLAN, CONTACT THE ENGINEER OF RECORD. CONFORM TO ASTM C150 TYPE I. LIME SHALL CONFORM TO ASTM C1207. ALL MASONRY CEMENT SHALL CONFORM TO ASTM C91. THICKNESS OF MORTAR SHALL NOT EXCEED %". FULL BEAD 12. STEM WALL TO BE A MAXIMUM OF SIX (6) COURSES TALL. CONTACT ENGINEER OF RECORD IF AND HEAD JOINTS SHALL BE USED. STEM WALL WILL EXCEED SIX (6) COURSES IN HEIGHT. 4. MASONRY GROUT SHALL CONFORM TO ASTM C476. fc OF GROUTHALL BE 3000 PSI MIN. THE � 13. WHERE THREADED RODS ARE EMBEDDED 12" INTO STEM WALLS, THE TOP TWO COURSES OF MAXIMUM AGGREGATE SIZE SHALL BE %" GRADED TO PRODUCE FIN GROUT IN CONFORMANCE STEM WALL MUST BE FILLED. WITH ASTM C476 AND C404. SLUMP OF GROUT SHALL BE 8 TO 10 INCHES. FRAMING NOTES NG TO A615, BAR DIA 5 MASONRLAP D E 60. PROVIDE B BARBARNFORM ONYALLLSPLICES.R PROVIDESPACERSASTM AS REQUIRED TO PROPERLY LOCATE 1. DESIGN OF WOOD COMPONENTS IN THIS STRUCTURE IS BASED ON THE 2017 F ORIDA BUILDING REINFORCING IN CELLS. CODE, RESIDENTIAL EDITION AND THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION. 6. THE CONTRACTOR SHALL PROVIDE ADEQUATE TEMPORARY BND CING OF ALL MASONRY CONSTRUCTION TO RESIST WIND, BACKFILLING, SOIL COMPACTION A OTHER NATURAL AND 2. DESIGN LOADING FOR THIS STRUCTURE IS FOUND IN THE LOAD TABLE ON THIS SHEET. CONSTRUCTION FORCES OCCURRING DURING CONSTRUCTION. THE BRACING SHALL REMAIN IN PLACE UNTIL THE STRUCTURE IS COMPLETE. 3. ALL FRAMING ANCHORS SHOWN ON PLANS ARE SIMPSON. ALTERNATE C NNECTORS ARE ACCEPTABLE PROVIDED EQUAL OR GREATER CAPACITIES ARE ACHIEVED. CONTACT ENGINEER 7 HORIZONTAL JOINT REINFORCING SHALL BE USED FOR ALL MASONRY CONSTRUCTION. OF RECORD IF EQUAL CAPACITIES ARE NOT APPARENT. AND SHALL CONSIST OF 9 GAGE, GALVANIZED, LADDER TYPE REINFORCING CONFORMING TO ASTM A82, SPACED AT 16" O.C. VERTICAL MAX. 4. ALL WOOD DIRECTLY EXPOSED TO CONCRETE, MASONRY OR SOIL SHALL BE PRESSURE TREATED. 8. WHEN GROUT POURS EXCEED 5 FEET IN HEIGHT, PROVIDE A CLEANiOUT HOLE AT THE BOTTOM CELL. CLEAN THE CELL BY REMOVING ALL MORTAR, DEBRIS, LOOSE AGGREGATES AND ANY 5. ALL WOOD DIRECTLY EXPOSED TO WEATHER SHALL BE PRESSURE TREATED. MATERIAL DELETERIOUS TO MASONRY GROUT. INSTALL AND SECURELY TIE THE VERTICAL STEEL REINFORCEMENT TOGETHER. CLOSE THE OPENING AFTER INSPECTION. 6. NAILS OR CONNECTORS EXPOSED TO WEATHER SHALL BE GALVANIZED. 9. ALL MASONRY WALLS SHALL BE SECURELY BRACED UNTIL FLOOR O ROOF SYSTEM HAS BEEN 7. DIMENSION LUMBER INSTALLED AND HAS BECOME CAPABLE OF STABILIZING THE WALLS. REINFORCED MASONRY 7.1. ALL MEMBER SIZES GIVEN IN THE DRAWINGS ARE NOMINAL DIMENSIONS UNITS SHALL BE FILLED SOLID WITH 3000 PSI GROUT AS INDICATED ON PLANS. 7.2. WHERE POSTS ARE CALLED OUT, HEADERS SHALL BEAR FULLY ON POSTS. 7.3. ALL BEAMS AND JOISTS NOT BEARING ON SUPPORTING MEMBERS SHALL BE FRAMED WITH 10. CASTCRETE PRECAST LINTELS TO BE USED OVER ALL OPENINGS, UNO. SEE PLAN FOR SIZE AND SIMPSON STRONG -TIE JOIST HANGERS OR EQUAL PER APPROVAL OF THE ENGINEER OF REINFORCEMENT. RECORD. THE JOIST HANGERS SHALL BE NAILED WITH NAILS MEETING THE DIAMETER AND LENGTH PER THE DETAILS. LOAD TABLE COMPONENT ANBD CLADDING 8. ALL NAILS SHALL BE COMMON NAILS, UNLESS OTHERWISE NOTED. NAIL SIZ S ARE DEFINED DESIGN PRESSURES BELOW: ROOF: LIVE LOAD: 20 0 PSF 8d = 0.131" x 2-1/2" S0.01 S1.01 DEAD LOAD: 7.0 PSF 10d = 0.148"x 3" - WIND SPEED: 130 MPH 12d = 0.148" x 3-1/4" C CEILING: 1.0 16d = 0.162" x 3-1/2" II LIVE LOAD: 10.0 PSF INTERIOR PRESSURE 21.6 LIVE LOAD -STORAGE: 30.0 PSF 9. WHERE FRAMING DETAILS SHOW FOOTINGS, SEE FOOTING DETAILS ON THE F UNDATION PLAN DEAD LOAD: 5.0 PSF AND/OR THE FOOTING DETAILS SHEET. L U Z w U- FLOOR: w 10. CONVENTIONAL FRAMING LUMBER IS 2x No.2 SYP UNLESS NOTED OTHERWISE. m LIVE LOAD: 40.0 PSF SHEET INDEX S0.01 S1.01 COVER PAGE/GENERAL NOTES FRAMING PLAN AND DETAILS DEAD LOAD: 10.0 PSF DECK LIVE LOAD: 50.0 PSF WIND LOADS: - WIND SPEED: 130 MPH EXPOSURE: C IMPORTANCE: 1.0 BUILDING CATEGORY: II ENCLOSED BUILDING: 21.6 INTERIOR PRESSURE 21.6 COEFFICIENT: 0.18 ROOF PITCH: MATCH EXISTING EFFECTIVE AREA,SF END ZONES, IDISF INTERIOR ZONES, PSF 0-20 24.4 - .0 24.4 -26.6 20-50 22.9 -28.8 22.9 -25.3 50-100 21.6 -217.2 21.6 -24.0 100-200 20.8 -24.4 20.8 -22.9 i 4 OFFICE COPY REVIEWED FOR CODE COMPLIANCE CITY OF ATLANTIC BEACH SEE PERMITS FOR ADDITIONAL REQUIREMENTS AND CONDITIONS REVIEWED BY: / i DATE: - 5 ! V ❑ a Q r m 04 N i O w C o z Q z w L: � z o z o o aO � w U ❑ W C/) D ❑ w W N LQ ch cO w 0 F" z U 0 20 F_ LL LL a) Z > Q LL 0 O L U Z w U- C m w o m Z Q z CDo U N w w Z Q J U) 0c> -i •` WAYNF Z_ 00 Q m <v° �• ';gym = - (9 : No 328ir 0 w U U) W F T~ 0 m T C) N mom' U m� 2 > a� NO ❑ U CL Q O U C N LQ ch cO LO C14 c aU p 20 U LL LL a) U O LO U N L cn 07 U- C m ID ami Q in m CDo 5 .c CR N U , v N ��;< O U C7 0) •` WAYNF ` r•0 1 FIC ••• 'pj� �X qT <v° �• ';gym = - (9 : No 328ir - 1k • F T~ Sheet No. S0.01 MAIN RESIDE AP LO GARAGE PORCH FIRST LEVEL WALL PLAN 1/4" = 1'-0" CONVENTIONAL FRAMING - ROOF 20 PSF LIVE LOAD, 10 PSF DEAD LOAD 1.25 DURATION FACTOR GRADE, SYP No.1 No.2 SPACING 16" 24" 16" 24" 2x6 14'-1" 12'-3" 13'-5" 11'-0" 2x8 18'-6" 16'-2" 17'-1" 13'-11" 2x10 23"-2" 18'-11" 20'-3" 16'-6" 2x12 26'-0" 22'-6" 23'-10" 19'-6" OVERIFY OR PLACE STUD GROUP UNDER BEAM BEARING. NUMBER OF A STUDS EQUALS THAT OF BEAM PLY, MIN 2 STUDS. FASTEN BEAM TO STUD GROUP WITH (1) MSTA24. FASTEN STUD GROUP TO PIER WITH LTT20B. USE 10d NAILS IN ALL HOLES. PLACE STUD GROUP UNDER BEAM BEARING. NUMBER OF STUDS EQUALS THAT OF BEAM PLY, MIN 2 STUDS. FASTEN BEAM TO aJ �� HEADER WITH (1) MSTA24. ii i a s �� a 1'-6" n�0 RAFTER TO LVL WITH A35. RAFTER TO EXISTING TOP CHORD WITH 10d NAILS AT 3" O.C. NEW 2X8 RAFTERS AT 16" O.C. PER BLE. NEW 11.25" LVLs, LOCATED AS SH N FOR DUCT ACCESS. L 2X4 BLOC ING ATZe O.C., FAST E06 S WITH (2) 10d NAILS. ----------------------- REMOVE UNUSED TRUSS MEMBERS ONLY AFTER NEW RIDGE AND RAFTERS ARE FULLY INSTALLED. � OOF SECTION MAX FIVE COURSES TALL. 8"X8" CMU PIER. FILL CELLS WITH 3000 psi CONCRETE AND #5 VERTICAL BAR VERTICAL REINFORCEMENT TO HAVE 12" BEND AT BOTTOM AND BE EMBEDDED 4" INTO TOP COURSE. 30"X30"X12" FOOTING WITH (3) #5 BARS EACH WAY FOOTING TO BEAR ON FIRM UNDISTURBED SOIL. &-3 ER FOOTING " = 1'-0" RAFTER TO EXISTING TOP CHORD WITH 10d NAILS AT 3" O.C. U) NU) � C7 0) N a � FRAMING NOTES AND LEGEND Z m 0 U 0 aU cn Q TOP AND BOTTOM PLATE MATERIAL: 2x No. 2 SYP, UNO. F— w STUD MATERIAL: 2x No. 2 SPF, UNO. o Q w HEADERS: 9 " w - Z ALL HEADERS ARE (2) 2x6 No. 2 SYP WITH TWO KINGS AND ONE CRIPPLE, v U zJ z UNO. FASTEN HEADER LUMBER TOGETHER USING (2) ROWS OF 16d (0.148" X m i 3.5") COMMON NAILS AT 12" ON CENTER. USE OSB SHIMS AS NECESSARY TO U O m MAKE THE HEADER THICKNESS EQUAL TO THAT OF THE WALL IT IS IN. SEE ma1°i 0 00 THE HEADER DETAIL FOR FASTENING SPECIFICATIONS. z' o < o 0 J a of u HEADER NOTATION IS: O U w NUMBER OF PLIES IN HEADER z W C D W NUMBER OF KING STUDS � x6.2:1 (2).M.2:1 W • t` q NUMBER OF CRIPPLE STUDS U) w N o SIZE OF DIMENSIONAL LUMBER .� o :• RIO O Z 0 m BEAM/HEADER w z of OVERIFY OR PLACE STUD GROUP UNDER BEAM BEARING. NUMBER OF A STUDS EQUALS THAT OF BEAM PLY, MIN 2 STUDS. FASTEN BEAM TO STUD GROUP WITH (1) MSTA24. FASTEN STUD GROUP TO PIER WITH LTT20B. USE 10d NAILS IN ALL HOLES. PLACE STUD GROUP UNDER BEAM BEARING. NUMBER OF STUDS EQUALS THAT OF BEAM PLY, MIN 2 STUDS. FASTEN BEAM TO aJ �� HEADER WITH (1) MSTA24. ii i a s �� a 1'-6" n�0 RAFTER TO LVL WITH A35. RAFTER TO EXISTING TOP CHORD WITH 10d NAILS AT 3" O.C. NEW 2X8 RAFTERS AT 16" O.C. PER BLE. NEW 11.25" LVLs, LOCATED AS SH N FOR DUCT ACCESS. L 2X4 BLOC ING ATZe O.C., FAST E06 S WITH (2) 10d NAILS. ----------------------- REMOVE UNUSED TRUSS MEMBERS ONLY AFTER NEW RIDGE AND RAFTERS ARE FULLY INSTALLED. � OOF SECTION MAX FIVE COURSES TALL. 8"X8" CMU PIER. FILL CELLS WITH 3000 psi CONCRETE AND #5 VERTICAL BAR VERTICAL REINFORCEMENT TO HAVE 12" BEND AT BOTTOM AND BE EMBEDDED 4" INTO TOP COURSE. 30"X30"X12" FOOTING WITH (3) #5 BARS EACH WAY FOOTING TO BEAR ON FIRM UNDISTURBED SOIL. &-3 ER FOOTING " = 1'-0" RAFTER TO EXISTING TOP CHORD WITH 10d NAILS AT 3" O.C. U) NU) C co 0) N O LO 0) Z C — W ¢ U 0 aU cn Q Cb F— O U Q Q J z> Q " O O w v U zJ ccli w +v J 7 LL c U O m Z ma1°i 2 tip o LV < - (h .0 CR 0 J U 0 � Y N O O C) cc C) z ao Q m � O W • t` q U U) N 3 U) .� :• RIO O m T � N mcg �,c� p> a0 N 6o 0 U Q o 0 Z Q Z U) _-j J 13- Q Z W _ 0 Q LL U NU) C co 0) N LO 0) * it C — W ¢ aU cn -`Qa v Cb 0 O U LL LL m U cc 0 (D N U ccli Ui +v J 7 LL c u m ma1°i Q tip o ) o < - (h .0 CR U) `r N 0 � Y N U 'T O C) cc C) co —3 m (WAY '� IF/ •• �k ' • t` q N 3 = .� :• RIO ` Sheet No. S1.01