536 Beach Avenue APEX • OFFICE COP "
Charlie Dixon III
Site Information ()
536 Beach Avenue, Duval
Structural Engineer of Record
Adam K Russell W
7
TrueHouse
4745 Suttonutton Park Court,Suite 402
Jacksonville, FL 32224
WIND LOADING(Cd=1.6) ROOF LOADING (Cd=1.25) FLOOR LOADING (Cd = 1.00)
MWFRS TCLL 20 psf TOLL 40 psf
130MPH(3 second gust)\ASCE 7-10 TCDL 7 psf TCDL 17 psf
Enclosed Structure(0.18) BOLL 0 psf+ NCLL 10 psf BOLL 0 psf
Exposure D BCDL 5 psf BCDL 5 psf
Occupancy Category II(Res)
FBC 2017 RES\TPI 2014
This Package inlcudes 30 truss designs with individual date of design
NO JOB ID TRS ID DATE NO JOB ID TRS ID DATE NO JOB ID TRS ID DATE
1 75322 F01 6/6/2018 29 75322 T09 6/6/2018
2 75322 F02 6/6/2018 30 75322 T10 6/6/2018
3 75322 F03 6/6/2018
4 75322 F04 6/6/2018
5 75322 F05 6/6/2018
6 75322 FG01 6/6/2018
7 75322 FG02 6/6/2018
8 75322 FGE01 6/6/2018
9 75322 FGE02 6/6/2018
10 75322 HJO1 6/6/2018
11 75322 HJO1A 6/6/2018
12 75322 HJ02 6/6/2018
13 75322 J01 6/6/2018
14 75322 J02 6/6/2018
15 75322 J03 6/6/2018
16 75322 JO3A 6/6/2018
17 75322 JO3B 6/6/2018
18 75322 J04 6/6/2018
19 75322 JO4A 6/6/2018
20 75322 J05 6/6/2018
21 75322 101 6/6/2018
22 75322 102 6/6/2018
23 75322 T03 6/6/2018
24 75322 T04 6/6/2018
25 75322 T05 6/6/2018
26 75322 T06 6/6/2018
27 75322 T07 6/6/2018
28 75322 108 6/6/2018 .01
`��111111116PI
Apex Technology is a ficticious name owned by Jax Apex Technology,Inc.,a Florida Corporation. Florida �' c ! Y f. y/94i/I,
Engineer Business No.7547-4745 Sutton Park Court,Suite 402 Jacksonville,FL 32224(904)821-5200 ,`.�, •, ••' \,�•C E At '•.'<c•
�I
1°V\ The seal on this index sheet indicates acceptance of professional engineering responsibility solely for the *�' No 585 ••.2
Truss Design Drawings listed above and attached. The suitability and use of each drawing for any 4Q
particualr building is the responsibility of the Building Designer,per ANSI/TPI 1-2002 Section 2
With my seal affixed to this sheet,I hereby certify that this serves as an index sheet in conformance with �ID:
APEX Rule 61G15-23.002(2)and 61G15-31.003 of the Florida Board of Professional Engineers T 0
This document may be signed and sealed with original or Docusign digital signature by the professional , • '• / • F 4/,4.-
,,
engineer identified in the adjacent professional engineer's seal.Printed copies of Docusign signature �ie S1 I . IDP••'\`✓v�
documents are not considered signed and sealed and the signature must be verified on any electronic ' ........`` \\
copies. `r4• ,/� NG,,s
•
Job#75322 BEARING INFORMATION
WOODTRUSS
QTY SPAN DESCRIPTION BRG# REACTION UPLIFT
1 09'00"00 FG01 FLAT 0.00/12 Pitch 2-Ply 1 1165.50 0.00
2 1165.50 0.00
1 08'03"08 FG02 FLAT 0.00/12 Pitch 2-Ply 1 1599.09 0.00
2 1420.45 0.00
4 09'09"05 HJO1 HIP_JACK 2.12/12 Pitch 1 -Ply 1 510.14 255.00
2 246.86 81.00
3 209.69 166.00
1 09'09"05 HJO1A HIP_JACK 2.12/12 Pitch 1 -Ply 1 369.52 158.00
2 373.15 197.00
3 45.27 0.00
4 223.03 169.00
1 02'11"04 HJO2 HIP_JACK 2.12/12 Pitch 1 -Ply 1 356.20 334.00
2 121.55 25.00
3 61.27 32.00
10 01'04"00 J01 JACK 3.00/12 Pitch 1 -Ply 1 278.33 243.00
2 125.12 30.00
3 151.46 39.00
10 03'00"00 J02 JACK 3.00/12 Pitch 1 -Ply 1 265.71 198.00
2 34.66 10.00
3 64.80 36.00
8 05'00"00 J03 JACK 3.00/12 Pitch 1 -Ply 1 310.67 205.00
2 62.58 0.00
3 114.23 80.00
1 05'00"00 JO3A JACK 3.00/12 Pitch 1 -Ply 1 268.51 196.00
2 223.53 74.00
3 10.78 10.00
4 29.93 21.00
1 05'00"00 J03B JACK 3.00/12 Pitch 1 -Ply 1 161.08 78.00
2 68.68 8.00
3 116.64 90.00
11 07'00"00 J04 EJACK 3.00/12 Pitch 1 -Ply 1 366.99 224.00
2 92.06 1.00
3 163.24 121.00
1 07'00"00 JO4A EJACK 3.00/12 Pitch 1 -Ply 1 265.73 185.00
2 274.40 108.00
3 40.00 0.00
4 78.14 53.00
1 07'00"00 J05 MONO 3.00/12 Pitch 1 -Ply 1 560.74 307.00
2 825.49 413.00
1 26'00"00 T01 HIPS 3.00/12 Pitch 1 -Ply 1 1733.94 949.00
2 1733.94 949.00
1 26'00"00 T02 HIPS 3.00/12 Pitch 1 -Ply 1 959.93 483.00
2 837.60 360.00
1 26'00"00 T03 HIPS 3.00/12 Pitch 1 -Ply 1 959.93 480.00
2 837.60 359.00
1 27'00"00 T04 SPEC 3.00/12 Pitch 1 -Ply 1 998.57 580.00
2 1074.77 628.00
1 27'00"00 T05 COMN 3.00/12 Pitch 1 -Ply 1 991.95 460.00
2 991.95 472.00
1 27'00"00 T06 COMN 3.00/12 Pitch 1 -Ply 1 991.95 468.00
Page 1 of 2
Job#75322 BEARING INFORMATION
QTY SPAN DESCRIPTION BRG# REACTION UPLIFT
2 991.95 478.00
1 27'00"00 T07 COMN 3.00/12 Pitch 1 -Ply 1 991.95 498.00
2 991.95 483.00
1 27'00"00 T08 COMN 3.00/12 Pitch 1 -Ply 1 1385.07 779.00
2 1786.65 1000.00
1 17'00"00 T09 COMN 3.00/12 Pitch 1 -Ply 1 673.47 334.00
2 546.98 232.00
1 17'00"00 T10 HIPS 3.00/12 Pitch 1 -Ply 1 517.35 300.00
2 1698.32 882.00
3 262.15 138.00
WOODFLOOR
QTY SPAN DESCRIPTION BRG# REACTION UPLIFT
3 19'00"00 F01 SY42 0.00/12 Pitch 1 -Ply 1 930.39 0.00
2 930.39 0.00
3 22'06"00 F02 SY42 0.00/12 Pitch 1 -Ply 1 923.66 0.00
2 1305.37 0.00
4 27'00"00 F03 SY42 0.00/12 Pitch 1 -Ply 1 864.32 0.00
2 1584.09 0.00
3 320.82 0.00
4 27'00"00 F04 SY42 0.00/12 Pitch 1 -Ply 1 356.63 0.00
2 1555.82 0.00
3 835.39 0.00
3 18'03"08 F05 SY42 0.00/12 Pitch 1 -Ply 1 895.28 0.00
2 895.28 0.00
1 19'00"00 FGE01 SY42GABL 0.00/12 Pitch 1 -Ply 1 1860.79 0.00
1 09'11"08 FGE02 SY42GABL 0.00/12 Pitch 1 -Ply 1 975.83 0.00
Total of Trusses 80
Maximun Height 04'00"10
Page 2 of 2
•
1. PERMANENT BRACING IS ALWAYS REQUIRED AND MUST BE PROVIDED BY THE BUILDING DESIGNER OR ENGINEER OF RECORD. PERMANENT
BRACING INCLUDES TOP CHORD BRACING, BOTTOM CHORD BRACING, COMPRESSION WEB MEMBER BRACING AND GABLE END LATERAL BRACING.
2. RECIEPT, STORAGE, ERECTION, FIELD INSTALLATION AND FIELD ASSEMBLY IS THE RESPONSIBILITY OF THE CONTRACTOR. IN THE ABSENCE OF
SPECIFIC BRACING REQUIREMENTS, THE CONTRACTOR SHALL ENSURE THAT THE TRUSSES ARE BRACED IN ACCORDANCE WITH BCSI-03.
3. NEVER EXCEED THE DESIGN LOADING SHOWN AND NEVER STACK MATERIALS ON INADEQUATELY BRACED TRUSSES.
4. PROVIDE COPIES OF THE TRUSS DESIGN TO THE BUILDING DESIGNER, ERECTION SUPERVISOR, PROPERTY OWNER AND ALL OTHER INTERESTED
PARTIES.
5. TOP CHORDS MUST BE SHEATHED OR PURLINS PROVIDED AT SPACING SHOWN ON DESIGN. BUILDING DESIGNER OR ENGINEER OF RECORD
REQUIRED TO PROVIDE THIS- SEE NOTE 1 ABOVE.
6. BOTTOM CHORDS REQUIRE RIGID CEILING OR CONTINUOUS LATERAL BRACING AT SPACING NOTED ON TRUSS PROFILE. BUILDING DESIGNER OR
ENGINEER OF RECORD REQUIRED TO PROVIDE THIS- SEE NOTE 1 ABOVE.
7. TRUSS TO TOP PLATE AND ALL OTHER CONNECTIONS NOT SHOWN ARE THE RESPONSIBILITY OF THE BUILDING DESIGNER.
8. DO NOT CUT OR ALTER TRUSS MEMEBER OR PLATE WITHOUT PRIOR APPROVAL OF A PROFESSIONAL ENGINEER. FOR TRUSS REPAIR DRAWINGS,
FAX REPAIR REQUEST TO 992-8700. FAX SHOULD CONTAIN TRUSS JOB NUMBER, TRUSS NUMBER, SPECIFIC SCOPE OF REPAIR AND CONTRACTOR
CONTACT INFO.
ax5
3.8
SYMBOL INDICATES REQUIRED
LATERAL BRACING. PERMANENT
SYMBOL AND TEXT INDICATES INDICATES LOCATION WHERE4 x 5 LATERAL BRACING IS THE
REQUIRED SIZE AND LOACTION OF RESPONSIBILITY OF THE BUILDING BEARINGS(SUPPORTS)OCCUR.
TRUSS PLATE. PLATE TEETH MUST = DESIGNER. ALL BEARINGS ARE CONSIDERED
BE FULLY EMBEDDED INTO TO BE NO 2 SYP(UNO).
LUMBER AND PLATES MAY NOT BE
CUT OR ALTERED. `
7 GENERAL NOTES
3 x 8414
AND DETAILS
4 a
/
2 x 4 4 x 5 %it* ,fV\
8-11-15 I TRUETRUSS
DIMINSIONS ARE SHOWN IN FEET-INCHES-SIXTEENTHS. /� A DIVISION OR
@ 1 RVEIlO S
APEX TECHNOLOGY ISA FICTITIOUS NAME OWNED BY JM APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 JACKSONVILLE,FL 32224-904.821.5200 TECHNOLOGY
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY.
GABLE TRUSS WEB 2x6 NO 2 SYP "L" BRACE GABLE TRUSS WEB 2x6 NO 2 SYP "T" BRACE
FASTENED TO GABLE WEB FASTENED TO GABLE WEB
W/.131" x 22" AT 6" O.C. J . W/.131" x 22" AT 6" O.C.
SECTION A-A SECTION A-A
OPTION 1 OPTION 2
(9' 8" - 12' 0") (9' 8" - 12' 0")
2x4 NO 2 SYP "L" BRACE
GABLE TRUSS WEB FASTENED TO GABLE WEB GABLE TRUSS WEB 2x4 NO 2 SYP "T" BRACE
W/.131" x 22" AT 6" O.C. FASTENED TO GABLE WEB
—' I W/.131" x 22" AT 6" O.C.
CI- SECTION B-B SECTION B-B
r
OPTION 2 OPTION 2
co (3' 8" - 9' 7") (3' 8" - 9' 7")
'
VERTICAL WEBS 3' 8" OR CONNECTION BETWEEN BOTTOM CHORD OF
LESS DO NOT REQUIRE GABLE END TRUSS AND WALL, AS WELL AS THE
b GABLE BRACES DESIGN AND SPECIFICATION OF PERMANENT
N - A BRACING OF THE ROOF SYSTEM IS THE GABLE END BRACING
' : rRESPONSIBILITY OF THE BUILDING DESIGNER. DETAIL
A A rn
r
r
ao B B •
v i (/ -,
1 1TRUETRUSS
A DIVISION OF
CONTINUOUS BEARING UNLESS NOTED OTHERWISE 6)TRUEHOUSEAPEX
APEX TECHNOLOGY ISA FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 JACKSONVILLE,FL 32224-904.821.5200 TECHNOLOGY
• THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY.
(3).148" x 3" TOE-NAILS @ TOP & BOTTOM
CHORD CONNECTION. (NAILS THROUGH
BACK SIDE OF GIRDER INTO END GRAIN OF
JACK TRUSS ARE NOT ALLOWED)
JACK
JACK (3).148" x 3" TOE-NAILS @ TOP & BOTTOM
CHORD CONNECTION FOR CORNER JACK.
_ SOME CORNER JACKS MAY REQUIRE
z SIMPSON LS30 IN LIEU OF TOE-NAILS.
< JACK REFER TO SHOP DRAWINGS.
a.H-
z
/\
w
U _w JACK
Q J
J
LL
o 0 O - (2).148" x 3" TOE-NAILS @ TOP & BOTTOM
c w 0z \\NJACK� CHORD CONNECTION.
awo
w Y Y_ CC w 0 0 QQ
TYPICAL HIP SET
NAILING DETAIL
"HJ" GIRDER
/ VARIES lAi/
TRUST BUSS
ADIVISION OF
@ l RUEHoUs1
APEX TECHNOLOGY ISA FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-0745 SUTTON PARK COURT,STE.402 JACKSONVILLE.FL 32224-904.821.5200 TECHNOLOGY
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY.
R
-IGGYBACK TRUSS
6"x 8"x z"PLYWOOD(or 17"OSB)GUSSET
APPLIED TO EACH FACE SPACED 48"O.C.
FASTEN WITH(4)8d COMMON INTO EACH
CHORD FROM EACH SIDE(TOTAL 16 NAILS).
MAXIMUM PURLIN SPACING 36"O.C.
REFER TO INDIVIDUAL BASE TRUSS DESIGN
FOR ACTUAL TOP CHORD PURLIN SPACING.
o ,9... 1 0KA ..... ,
n •ti 0 ...
PIGGYBACK TRUSS
ATTACH PURLIN TO TOP CHORD OF BASE TRUSS
EACH BASE TRUSS WITH (2).131"x 23"
\ OPTION 1
6'40
MAXIMUM PURLIN SPACING 24"O.C. TO �G2k
FOR ACTUUALEFER TO DIVIDUAL TOP CHORDSE PURLIN SSPACING. r'JS DESIGN F�CFw/ O 3SYASC
xl
0 01 SS �w1 °C
�I PIGGYBACK TRUSS
CONNECTION DETAIL
Dill
\_ '
BASE TRUSS
ATTACH PIGGY BACK TO EACH PURLIN\ 0 FOR PIGGY BACK TRUSSES WITH SPANS LESS THAN 12'SCAB i / i
WITH (2).131"x 23' MAY BE OMMITED PROVIDED THAT THE ROOF SHEATHING IS
ATTACH PURLIN TO TOP CHORD OF * CONTINUOUS OVER JOINT(SHEATHING TO OVERLAP A MINIMUM
���
EACH BASE TRUSS WITH(2).131"x 23" OF 12"OVER JOINT).
A DIVISION OF
OPTION 2 QTRUEHousE) i/)!P'aE , 41: ,
APEX TECHNOLOGY IS A FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 JACKSONVILLE,FL 32224-504.421.5200 TECHNOLOGY
• THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY.
36" MAXIMUM FLAT
TOP CHORD SPAN
FASTEN SCABS TO CONTINUOUS 2x4 NO 2
SYP RIDGE BEAM W/(2).131"x 22"
OR /
2x4 NO 2 SYP BLOCKING BETWEEN CAPS M/ /JP�O��S'
U cF yA
FASTENED W/(2).131"x 22"AT EACH END __'' '�;� ..-_ /�,2/4 S•73, cgeq
4614
`�� �� F TR�c
ss
(1) PURLIN AT MIDSPAN OF
BASE TRUSS ACH TRUSS TOP CHORD
WITH (2).131"x 2i"
/\
CONVENTIONAL
FRAMED PIGGYBACK
DETAIL
TRUETRUSS ,f1Pl\
A 1 DIVISION OF
RUEHOUSE
APEX TECHNOLOGY ISA FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 JACKSONVILLE,FL 32224-504.821.5200 TECHNOLOGY
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY.
(2)16d TOP NAILS
// f ER STRAP —1,-- (2)16d TOP NAILS
PER STRAP
1 I \ \ \ \
/ (1)16d FACE NAIL (1)16d FACE NAIL
.,, ,, —PV
STRAP �ER STRAP
V \ \ \\ \
A (3)16d STRAIGHT \ (3)16d STRAIGHT \
AILS PER SIDE AILS PER SIDE
/ l to
' / 1 D1K/ \ 1 THA422 / li //1
—N—DEPTH AND PLIES VARY THA422
FLOOR TRUSS TO BEAM FLOOR TRUSS TO ROOF GIRDER
(2)16d TOP NAILS
/r PER STRAP
i><\
NN
(1)16d FACE NAIL
'ER STRAP \ \
(3)16d STRAIGHT \ THA422 CONNECTIONS
AILS PER SIDE
tor
N /
1
>< ' TRUETRUSS ,,V\
A DIVISION OF
THA422 @TRUEHougr APEX
FLOOR TRUSS TO FLOOR TRUSS
APEX TECHNOLOGY ISA FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 JACKSONVILLE.FL 32224-904.821.5200 TECHNOLOGY
THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY.
•
24" TYP I I
N X 4 X ' X COMMON TRUSSES
@ 24" O.C.
z
W J MAX 12"OVERHANG UNLESS I k•
W < DESIGNED BY OTHERS
CO p VALLEY SET Q
0 0 '� 24" O.C.
O Uw :�=uJ m �A111111)4111011
)
Cr
;�, t,S
COMMON TRUSSES
@24" O.C.
0 /
CUMMUN I KUSSES 0, 2?
TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING
SYSTEMS, 2x6 "STRONGBACKS" SHOULD BE LOCATED EVERY 8 TO
10 FEET ALONG A FLOOR TRUSS.
STRONGBACK MAY BE POSITIONED DIRECTLY UNDER THE TOP CHORD OR DIRECTLY ABOVE THE BOTTOM
CHORD. SECURELY FASTEN TO THE TRUSS USING ANY OF THE METHODS ILLUSTRATED BELOW.
111.N2MillirrAH\LNIIIIVAIIVIIIVIMI AllaillirgN
IIXI _
M
USE SIMPSON ATTACH TO VERTICAL ATTACH TO VERTICAL ATTACH 2x4 VERTICAL TO FACE
H2.5 TO ATTACH WEB WITH (3)12. WEB WITH (3)12d IF TRUSS. FASTEN TO TOP
2x6 TO CHORD. COMMON WIRE NAILS. COMMON WIRE NAILS. AND BOTTOM CHORD WITH (2)12d
COMMON IN EACH CHORD.
IIdazi .000AIHNiih. /gm\ 1 .%7 ...\\ ./..N. _
.,moi
B1
NW \\\\\\ \
\\ \ \ LOCKING
7B
s s s s\
TRUSSES TYPICAL SPLICE 48" 2x6 AS REQUIRED FLOOR TRUSS
\-BEARING WALL STRONG BACKS
THE STRONGBACKS SHOULD EITHER BE SECURED TO ADJACENT PARTITION WALLS OR ALTERNATE"X"
BRIDGING SHOULD BE USED TO TERMINATE THE BRACING MEMBERS. IF SPLICING IS NECESSARY, USE
A 4'-0" LONG SCAB CENTERED OVER THE SPLICE AND JOIN WITH (12)12d NAILS EQUALLY SPACED. ,,V\
'j`
ALTERNATE METHOD OF SPLICING: 1 RUETRUSS
OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4'-0"AND FASTEN WITH (12)12d COMMON WIRE NAILS A DIVISION OF
STAGGERED AND EQUALLY SPACED. (TO BE USED ONLY WHEN STRONGBACK IS NOT ALIGNED WITH A
VERTICAL) @TRUEHOUSE) APEX
APEX TECHNOLOGY IS A FICTITIOUS NAME OWNED BY JAX APEX TECHNOLOGY INC.,A FLORIDA CORPORATION FBPE CA NO.7547-4745 SUTTON PARK COURT,STE.402 JACKSONVILLE,FL 32224-504.821.5200 TECHNOLOGY
• THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF APEX TECHNOLOGY AND IS TO BE USED ONLY IN CONJUNCTION WITH TRUSSES DESIGNED BY APEX TECHNOLOGY.
75322 Ply:1 SEQN:17516/T25/SY42 -
Sherman Res. Qty: 3 FROM: DRW:
F01 Wgt:103.6 lbs ... / ... 06/06/2018
9'3" I 11' I 19'
9,3" 1,9" 8'
I
rI- 26" I 2'6'12--I-26 12 1'3"12
I ---I I---2'6°12 I rs°,z--I N
(TYP)
W=3X4
1111.5X3 =3X8 1111.5X3 m3X3 1111.5X3 =3X4 1111.5X3 =3X8 1111.5X3
SA B C D E F G H I T9 J
T ?'a K
`_v
1 \ Ay 8'1"2
R Q P 0 N M Lf O
=3X8 3X8[5] W=H0310 =3X3 1111.5X3 3X8[14] =3X8
1 19' 1
Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs)
TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udell L/# Loc R /U /Rw /Rh /RL /W
TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.340 E 653 480 R 930 /- /- /- /- /5.5
BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.718 E 460 360 L 930 /- /- /- /- /3.5
BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.045 B - - R Min Brg Width Req= 1.5
Des Ld: 62.00 EXP:NA HORZ(TL): 0.069 B - - L Min Brg Width Req= 1.5
NCBCLL:10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:2.0 Bearings R&L are a rigid surface.
Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2017 RES Max TC CSI: 0.724
Load Duration:1.00 BCDL:NA psf TPI Std: 2014 Max BC CSI: 0.833 Maximum Top Chord Forces Per Ply(lbs)
Spacing:19.2" MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI: 0.612 Chords Tens.Comp. Chords Tens. Comp.
C&C Dist a:NA ft FT/RT:12(0)/10(0) Mfg Specified Camber: A-B 1 0 F-G 0 -2819
I:NA GCpi:NA Plate Type(s): B-C 0 -2831 G-H 0 -2819
Wind Duration:NA WAVE,HS VIEW Ver:18.01.008.0430.21 C-D 0 -2831 H-I 0 -2819
Lumber End Vertical Attachment D-E 0-3458 I-J 1 0
E-F 0-3461
Value Set:13B(Effective 6/1/2013) Attach notched end vertical(s)to next end vertical
Top chord 4x2 SP#2:T2 4x2 SP#1: using(3)qty.10d box or(0.128"x3"min)gun nails,or
Bot chord 4x2 SP#1 (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire Maximum Bot Chord Forces Per Ply(lbs)
Webs 4x2 SP#3 staples,through wide face;or(3)qty.16-Gauge,1" Chords Tens.Comp. Chords Tens. Comp.
Crown(minimum),1-1/2"length wire staples on each
Lumber value set"13B"uses design values narrow face. R-Q 1668 0 0-N 3461 0
approved 1/30/2013 by ALSC Q-P 3404 0 N-M 3459 0
Additional Notes P-O 3404 0 M-L 1665 0
Plate Shift Table +2x6 continuous strongback.See detail
JT Plate Chord JT Plate Chord STRBRIBR1014 for bracing and bridging Maximum Web Forces Per Ply(lbs)
No Size Shift Bite No Size Shift Bite recommendations. Webs Tens.Comp. Webs Tens. Comp.
[5] 3X8 3.50 L 1.25 [14] 3X8 3.50 R 1.25 Truss must be installed as shown with top chord up.
S-R 0 -9 N-F 116 -48
Purlins The overall height of this truss excluding overhang is A-R 0 -97 F-M 0 -867
In lieu of structural panels or rigid ceiling use purlins 1-4-0. R-B 0 -1854 H-M 0 -254
to laterally brace chords as follows: B-Q 1285 0 M-I 1275 0
Chord Spacing(in oc) Start(ft) End(ft) C-Q 0 -230 I-L 0 -1851
TC 24 0.25 18.75 Q-D 0 -635 J-L 0 -98
BC 120 0.25 18.75 D-O 368 -178 L-K 0 -9
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above. O-E 50 -185
Loading
Bottom chord checked for 10.00 psf non-concurrent
live load.
Camber
Max JT VERT DEFL:LL:0.34"DL:0.47".See detail
DEFLCAMB1014 for camber recommendations.
NOTES:
f 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
6-1 i2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc..Florida Corporation. Florida Engineer /)0/"Y\Business No.7547-4745 Sutton Park Court.Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
Tru eHo use Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell
PE No.60839 PE No.58544 PE No.71457 PE No.77693
75322 Ply:1 SEAN:17420/T32/SY42
Sherman Res. Qty: 3 FROM: DRW:
F02 Wgt:126.0 lbs ... / ... 06/06/2018
9'3" 11'0"8 276"
I
I I
9,3" 1'9"8 11'5"8
2'6" �3"1�
(TYP)
1I I..-26"12-I-2'6"12-I I-2'6"12 I 2'6"12--}-2"6"12- I--1'8"-.-11-.-17.'4 H
W=3X4
=3X8 =3X3 =3X4 =3X8 =3X3 =3X3
A B C D E Fye G H I J K L
9.4-
I V 7.1 M A_
1_ q)8.1..2
V U T S R a "P 0 N `I'
=3X8 =3X8[5] W=H0310 w3X8[14] 3X8[17] =3X3 113X3
=3X3
1 19' 1 3'6"-._I
I 22'6" I
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs)
TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W
TCDL: 17.00 Speed:NA mph Pf:NA Ce:NA VERT(LL): 0.343 E 649 480 V 924 /- /- /- /- /5.5
BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.754 E 452 360 P 1305 /- /- /- /- /3.5
BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.046 B - - V Min Brg Width Req= 1.5
Des Ld: 62.00 EXP:NA HORZ(TL): 0.071 B - - P Min Brg Width Req= 1.5
NCBCLL:10.00 Mean Height:NA ft Code I Misc Criteria Creep Factor:2.0 Bearings V&P are a rigid surface.
Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2017 RES Max TC CSI: 0.823
Load Duration:1.00 BCDL:NA psf TPI Std: 2014 Max BC CSI: 0.872 Maximum Top Chord Forces Per Ply(lbs)
Spacing:19.2" MW FRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI:0.637 Chords Tens.Comp. Chords Tens. Comp.
C&C Dist a:NA ft FT/RT:12(0)/10(0) Mfg Specified Camber: A-B 1 0 G-H 0 -2722
I:NA GCpi:NA Plate Type(s): B-C 0-2803 H-I 0 -2722
Wind Duration:NA WAVE,HS VIEW Ver:18.01.00B.0430.21 C-D 0-2803 I-J 465 0
Lumber End Vertical Attachment D-E 0-3402 J-K 465 0
Value Set:136(Effective 6/1/2013) Attach notched end vertical(s)to next end vertical F-F 0-3405 K-L 123 0
Top chord 4x2 SP#2 using(3)qty.10d box or(0.128"x3"min)gun nails,or F-G 0-2722
Bot chord 4x2 SP#1 (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire
Webs 4x2 SP#3 staples,through wide face;or(3)qty.16-Gauge,1" Maximum Bot Chord Forces Per Ply(lbs)
Crown(minimum),1-1/2"length wire staples on each Chords Tens.Comp. Chords Tens. Comp.
Lumber value set"136"uses design values narrow face.
approved 1/30/2013 by ALSC V-U 1655 0 R-Q 3402 0
Additional Notes U-T 3361 0 Q-P 1553 0
Plating Notes +2x6 continuous strongback.See detail T-S 3361 0 P-O 0 -130
All plates are 1.5X3 except as noted. STRBRIBR1014 for bracing and bridging S-R 3405 0 0-N 0 -3
recommendations.
Plate Shift Table
Truss must be installed as shown with top chord up. Maximum Web Forces Per Ply(lbs)
JT Plate Chord JT Plate Chord The overall height of this truss excluding overhang is Webs Tens.Comp. Webs Tens. Comp.
No Size Shift Bite No Size Shift Bite
[5] 3X8 3.50 L 1.25 [14] 3X8 3.50 R 1.25 1-4-0. W-V 0 -9 H-Q 0 -257
[17] 3X8 2.50 R 1.25 A-V 0 -97 Q-I 1339 0
V-B 0 -1839 I-P 0 -1878
Purlins B-U 1269 0 J-P 0 -226
In lieu of structural panels or rigid ceiling use purlins C-U 0 -229 P-K 0 -421
to laterally brace chords as follows: U-D 0 -617 K-0 75 0
Chord Spacing(in oc) Start(ft) End(ft) D-S 352 -251 0-L 0 -148
TC 24 0.25 22.38 S-E 81 -179 L-N 15 0
BC 120 0.25 22.50
Apply purlins to any chords above or below fillers R-F 144 37 M-N 9 0
at 24"OC unless shown otherwise above. F-Q 0 -989
Loading
Bottom chord checked for 10.00 psf non-concurrent
live load.
NOTES:
r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
16(jfJt)
2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer /ft/\
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
TrueHouse PE No.Michael
0839lowski
Jeffrey
No.58r544 Derek B
neson PE No.71457y PE No.77769311
75322 Ply:1 SEAN:17424/T21/SY42 •
Sherman Res. Qty:4 FROM: DRW:
F03 Wgt:145.6 lbs ... / ... 06/06/2018
L 27' 1
I
9'3" 110"8 2210"8 124181 z'1o•a
9'3" 1'9"8 11'10" 1'3"
I-2'6"-I 1-- -I I~12 4"1~I
(TYP)
III I-26"12-{f--76.12-I f-26.12-f-2'6"12-I-2'6"12--I--26.12-1 ?I
=3X8 -3X3 =3X4 W=3X4 =4X8 =3X4[18] =3X3
ZA B C D E F GH I J K T9 L M NQ
i -
41IY X W V U T R Q P$
=3X8 =3X8 =3X3 W=H0310 w3X8[17] =3X3 =4X5
3X8[13]
1 18'10"4 1 81"12 i
I 27' I
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Def1ICSI Criteria ♦Maximum Reactions(lbs)
TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W
TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.338 E 660 480 Y 864 /- /- /- /- /5.5
BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.759 E 424 360 S 1584 /- /- /- /- /3.5
BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.045 B - - P 321 /30 /- /- /- /3.5
Des Ld: 62.00 EXP:NA HORZ(TL):0.071 B - - Y Min Brg Width Req= 1.5
NCBCLL:10.00 Mean Height:NA ft Code I Misc Criteria Creep Factor:2.0 S Min Brg Width Req= 1.5
Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2017 RES Max TC CSI: 0.835 P Min Brg Width Req= 1.5
Load Duration:1.00 BCDL:NA psf TPI Std: 2014 Max BC CSI: 0.889 Bearings Y,S,&P are a rigid surface.
Spacing:19.2" MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI: 0.698
C&C Dist a:NA ft FT/RT:12(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs)
I:NA GCpi:NA Plate Type(s): Chords Tens.Comp. Chords Tens. Comp.
Wind Duration:NA WAVE,HS VIEW Ver:18.01.008.0430.21 A-B 1 0 H-I 0 -2057
Lumber End Vertical Attachment B C 0-2558 I-J 1211 0
Value Set:13B(Effective 6/1/2013) Attach notched end vertical(s)to next end vertical D-E 0-2959 J-K 12115 4
Topchord 4x2 SP#2:T2 4x2 SP#1: using(3)qty.10d box or(0.128"x3"min)gun nails,or
D-E 0-2919 K-L 250 -384
E-F 0-2918 L-M 240 -390
Bot chord 4x2 SP#1:62 4x2 SP#2: (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire
Webs 4x2 SP#3 staples,through wide face;or(3)qty.16-Gauge,1" F-G 0 -2057 M-N 1 0
Crown(minimum),1-1/2"length wire staples on each G-H 0 -2057
Lumber value set"136"uses design values narrow face.
approved 1/30/2013 by ALSO
Maximum Bot Chord Forces Per Ply(lbs)
Additional Notes Chords Tens.Comp. Chords Tens. Comp.
Plating Notes +2x6 continuous strongback.See detail
All plates are 1.5X3 except as noted. STRBRIBR1014 for bracing and bridging Y-X 1535 0 T-S 762 0
recommendations. X-W 2981 0 S-R 212 -566
Plate Shift Table Truss must be installed as shown with top chord up. W V 2918 0 R-Q 390 -240
JT Plate Chord JT Plate Chord The overall height of this truss excludingoverhangis V-U 2913 0 Q-P 390 -237
No Size Shift Bite No Size Shift Bite 9U-T 2913 0
[13] 3X8 4.00 R 1.25 [17] 3X8 2.25 R 1.25 1440.
[18] 3X4 1.75 R 1.25
Maximum Web Forces Per Ply(lbs)
Purlins Webs Tens.Comp. Webs Tens. Comp.
In lieu of structural panels or rigid ceiling use purlins Z-Y 0 -9 T-I 1465 0
to laterally brace chords as follows: A-Y 0 -96 I-S 0 -1975
Chord Spacing(in oc) Start(ft) End(ft) Y-B 0-1706 J-S 0 -289
TC 24 0.25 26.75 B-X 1131 0 S-K 0 -976
BC 120 0.25 26.75 C-X 0 -225 K-R 533 0
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above. X-D 0 -467 R-L 0 260
D-W 224 -299 Q-M 16 -78
Loading W-E 103 -120 M-P 263 -435
Bottom chord checked for 10.00 psf non-concurrent V-F 155 5 N-P 0 127
live load. F-T 0-1052 P-O 0 -10
G-T 0 -244
Camber
Max JT VERT DEFL:LL:0.34"DL:0.46".See detail
DEFLCAMB1014 for camber recommendations.
NOTES:
f 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include SCSI 1-03,
should be used in conjunction with the architectural plans during installation.
(11'H) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer Jf*/\
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
Tru eHouse PE No.0839 Kozlowski PE No.58544son PE No 7 457y PE No.77769311
•
75322 Ply:1 SEQN:17427/T30/SY42
Sherman Res. Qty:4 FROM: DRW:
F04 Wgt:144.2 lbs ... / ... 06/06/2018
4'1"8
1`-1
210"8 13• 168" 19 27'
2'10"8 12'6"8 2'4" 8'
I-2'6"--1
(TYP)
I I I---2'1"4--{--2'612-I--Z6"12--4---2'6"12--1--2'6"12,{ I-2.6"12-{-2'6"12-I I
=3X4
=3X3 3X4[7] =3X8 W=3X4 =3X3 =3X8
A B C D E F G H I J K L M
T 3e Y.- \ T9 LN
ry2 'J' 8'1'2
X W V ''U T S R Q P OP
=4X5 w3X3[6] =3X8[9] W=3X4 E3X8 =3X8
=3X8[13]
r 810"4 1 18'1"12 1
I 27' I
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DefIICSI Criteria ♦Maximum Reactions(lbs)
TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W
TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.268 Q 802 480 X 357 /- /- i- /- /5.5
BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.609 Q 521 360 U 1556 /- /- /- /- /3.5
BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.026 0 - - 0 835 /- /- /- /- /3.5
Des Ld: 62.00 EXP:NA HORZ(TL):0.041 0 - - X Min Brg Width Req= 1.5
NCBCLL:10.00 Mean Height:NA ft Code I Misc Criteria Creep Factor:2.0 U Min Brg Width Req= 1.5
Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2017 RES Max TC CSI: 0.643 0 Min Brg Width Req= 1.5
BCDL:NA sf TPI Std: 2014 Max BC CSI: 0.575 Bearings X,U,&0 are a rigid surface.
Load Duration:1.00 P
Spacing:19.2" MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI: 0.657
C&C Dist a:NA ft FT/RT:12(0)/10(0) Mfg Specified Camber. Maximum Top Chord Forces Per Ply(lbs)
I:NA GCpi:NA Plate Type(s): Chords Tens.Comp. Chords Tens. Comp.
Wind Duration:NA WAVE VIEW Ver:18.01.00B.0430.21 A-B 1 0 G-H 0 -2020
•
Lumber End Vertical Attachment B-C 119 -490 H-I 0 -2020
Value Set:13B(Effective 6/1/2013) Attach notched end vertical(s)to next end vertical C-D 15 -484 I-J 0 -2763
Top chord 4x2 SP#1 :T2 4x2 SP SS: using(3)qty.10d box or(0.128"x3"min)gun nails,or D-E 115110 J-K 0 -2439
Bot chord 4x2 SP#2:B2 4x2 SP SS: (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire E-F 1151 0 K-L 0 -2439
staples,through wide face;or(3)qty.16-Gauge,1" F-G 0-2020 L-M 1 0
Webs 4x2 SP#3 Crown(minimum),1-1/2"length wire staples on each
Lumber value set"13B"uses design values narrow face. Maximum Bot Chord Forces Per Ply(lbs)
approved 1/30/2013 by ALSO
Additional Notes Chords Tens.Comp. Chords Tens. Comp.
Plating Notes +2x6 continuous strongback.See detail X-W 489 -117 S-R 2759 0
All plates are 1.5X3 except as noted. STRBRIBR1014 for bracing and bridging W-V 490 -119 R-Q 2763 0
recommendations. V-U 244 -474 Q-P 2765 0
Plate Shift Table U-T 808 0 P-O 1470 0
Truss must be installed as shown with top chord up.
JT Plate Chord JT Plate Chord T-S 8013 0
The overall height of this truss excluding overhang is
No Size Shift Bite No Size Shift Bite
[6] 3X3 1.25 L 1.25 [7] 3X4 1.75 L 1.25 1-4-0.
[9] 3X8 2.50 L 1.25 [13] 3X8 2.75 R 1.25 Maximum Web Forces Per Ply(lbs)
Webs Tens.Comp. Webs Tens. Comp.
Purlins Y-X 0 -10 G-S 0 -248
In lieu of structural panels or rigid ceiling use purlins A-X 0 -122 S-I 0 -963
to laterally brace chords as follows: X-B 130 -544 I-R 147 -22
Chord Spacing(in oc) Start(ft) End(ft) B-W 38 -65 Q-J 51 -116
TC 24 0.25 26.75 C-V 0 -211 J-P 0 -547
BC 120 0.25 26.75 V-D 556 0 K-P 0 -280
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above. D-U 0-1030 P-L 1071 0
E-U 0 -279 L-O 0 -1634
Loading U-F 0-1888 M-O 0 -99
Bottom chord checked for 10.00 psf non-concurrent F-S 1379 0 O-N 0 9
live load.
Camber
Max JT VERT DEFL:LL:0.27"DL:0.39".See detail
DEFLCAMB1014 for camber recommendations.
NOTES:
NI" 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03.
should be used in conjunction with the architectural plans during installation.
(1'H) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer if*/\
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
Tru eHouse PE No.Michael
08391owski
Jeffrey
No.58544son PE No. Murray7457PE No.77769311
75322 Ply:1 SEAN: 17430/T29/SY42
Sherman Res. Qty: 3 FROM: DRW:
F05 Wgt:100.8 lbs ... / ... 06/06/2018
8' I 10'3"8 I 18'3"8
I
8' 2'3"8 8'
I-I --2'6" - 2'6"12----I—2'6"12--.-I I—2'6"12—I 2'712—I
(TYP)
1111.5X3
1111.5X3 =3X8 1111.5X3 =3X3[7] 3X3[10] W=3X4 =3X8 1111.5X3
A B C D E F G H I
T 3e R.,
T2 4_J
Q P 0 N M L K1 T
=3X8 =3X8 1111.5X3 1111.5X3 =3X8 =3X8
W=H0310
i 18'3"8 i
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs)
TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W
TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.258 M 829 480 Q 895 /- /- /- /- /3.5
BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.599 M 532 360 K 895 /- /- /- /- /3.5
BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.034 K - - Q Min Brg Width Req= 1.5
Des Ld: 62.00 EXP:NA HORZ(TL):0.055 B - - K Min Brg Width Req= 1.5
NCBCLL:10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:2.0 Bearings Q&K are a rigid surface.
Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2017 RES Max TC CSI: 0.463
Load Duration:1.00 BCDL:NA psf TPI Std: 2014 Max BC CSI: 0.594 Maximum Top Chord Forces Per Ply(lbs)
Spacing:19.2" MWFRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI:0.572 Chords Tens.Comp. Chords Tens. Comp.
C&C Dist a:NA ft FT/RT:12(0)/10(0) Mfg Specified Camber: A-B 1 0 E-F 0 -2676
I:NA GCpi:NA Plate Type(s): B-C 0-2679 F-G 0 -2676
Wind Duration:NA WAVE,HS VIEW Ver:18.01.008.0430.21 C-D 0-2679 G-H 0 -2676
Lumber End Vertical Attachment D-E 0-3204 H-I 1 0
Value Set:13B(Effective 6/1/2013) Attach notched end vertical(s)to next end vertical
Top chord 4x2 SP SS:T2 4x2 SP#2: using(3)qty.10d box or(0.128"x3"min)gun nails,or Maximum Bot Chord Forces Per Ply(lbs)
Bot chord 4x2 SP#1:B2 4x2 SP SS: (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire Chords Tens.Comp. Chords Tens. Comp.
Webs 4x2 SP#3 staples,through wide face;or(3)qty.16-Gauge,1" Q-P 1593 0 N-M 3204 0
Crown(minimum),1-1/2"length wire staples on each
Lumber value set"13B"uses design values narrow face. P-0 3204 0 M-L 3203 0
approved 1/30/2013 by ALSC 0-N 3204 0 L-K 1594 0
Additional Notes
Plate Shift Table +2x6 continuous strongback.See detail Maximum Web Forces Per Ply(lbs)
JT Plate Chord JT Plate Chord STRBRIBR1014 for bracing and bridging Webs Tens.Comp. Webs Tens. Comp.
No Size Shift Bite No Size Shift Bite recommendations.
[7] 3X3 1.25 R 1.25 [10] 3X3 1.25 L 1.25 Truss must be installed as shown with top chord up. R-Q 0 -9 M-E 105 -78
A-Q 0 -98 E-L 0 -786
Purlins The overall height of this truss excluding overhang is Q-B 0-1770 G-L 0 -261
In lieu of structural panels or rigid ceiling use purlins 1-4-0. B-P 1201 0 L-H 1196 0
to laterally brace chords as follows: C-P 0 -264 H-K 0 -1772
Chord Spacing(in oc) Start(ft) End(ft) P-D 0 -787 I-K 0 -97
TC 24 0.25 18.04 D-N 104 -79 K-J 0 -9
BC 120 0.25 18.04
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent
live load.
Camber
Max JT VERT DEFL:LL:0.26"DL:0.40".See detail
DEFLCAMB1014 for camber recommendations.
NOTES:
'N-
(11'1-1)
1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03.
should be used in conjunction with the architectural plans during installation.
TH 2.Apex Technology is a fictitious name owned by lax Apex Technology Inc.,Florida Corporation. Florida Engineer
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
Tru eHo u se Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell
PE No.60839 PE No.58544 PE No.71457 PE No.77693
75322 Ply:2 SEON:17518/T15/FLAT
Sherman Res. Qty: 1 FROM: DRW:
FG01 Wgt:86.8 lbs ... / ... 06/06/2018
3'1"4 510"12 9'
H
3'1"4 I 2'9"8 I 3'1"4
IIIC4 IIItX4
A------4X5 =4X5 D
T P 5 W1
Th
1 H G F E81„2
-1$1-
13X4 -4X5 =4X5 III 3X4
r 9' 1
2'11"8 3'1" 2'11"8
I' 2'11"8 I 6'0"8 I 9' H
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defi/CSI Criteria ♦Maximum Reactions(lbs)
TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W
TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.016 B 999 480 H 1165 /- /- /- /- /5.5
BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.102 B 999 360 E 1165 /- /- /- /- /3.5
BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.004 A - - H Min Brg Width Req= 1.5
Des Ld: 62.00 EXP:NA HORZ(TL):0.014 A - - E Min Brg Width Req= 1.5
NCBCLL:10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:2.0 Bearings H&E are a rigid surface.
Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2017 RES Max TC CSI: 0.363
Load Duration:1.00 BCDL:NA psf TPI Std: 2014 Max BC CSI: 0.472 Maximum Top Chord Forces Per Ply(lbs)
Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:No Max Web CSI:0.541 Chords Tens.Comp. Chords Tens. Comp.
C&C Dist a:NA ft FT/RT:30(0@10(0) Mfg Specified Camber: A-B 0-1125 C-D 0 -1125
I:NA GCpi:NA Plate Type(s): B-C 0 -1178
Wind Duration:NA WAVE VIEW Ver:18.01.00.0323.07
Lumber Purlins Maximum Bot Chord Forces Per Ply(lbs)
Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins Chords Tens.Comp. Chords Tens. Comp.
Top chord 2x4 SP#2 to laterally brace chords as follows: H-G 57 0 F-E 57 0
Bot chord 2x4 SP#2 Chord Spacing(in oc) Start(ft) End(ft) G-F 1178 0
Webs 2x4 SP#3:W1 2x6 SP#2: TC 24 0.00 9.00
BC 108 0.00 9.00
Lumber value set"13B"uses design values Apply purlins to any chords above or below fillers Maximum Web Forces Per Ply(lbs)
approved 1/30/2013 by ALSC at 24"OC unless shown otherwise above. Webs Tens.Comp. Webs Tens. Comp.
Nailnote The TC of this truss shall be braced with attached A-H 0 -562 C-F 0 -379
Nail Schedule:0.131"x3",min.nails spans at 24"oc in lieu of structural sheathing. A-G 1136 0 F-D 1136 0
Top Chord:1 Row @10.25"o.c. G-B 0 -379 D-E 0 -562
Bot Chord:1 Row @12.00"o.c.
Webs :1 Row @ 4"o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
Special Loads
----(Lumber Dur.Fac.=1.00/Plate Dur.Fac.=1.00)
TC:From 249 plf at 0.00 to 249 plf at 9.00
BC:From 10 plf at 0.00 to 10 plf at 9.00
Plating Notes
Plate positions consider a 0.50 inch truss perimeter
edge distance.
Additional Notes
Truss must be installed as shown with top chord up.
The overall height of this truss excluding overhang is
1-4-0.
NOTES:
N- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
6'H) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
TrueHouse ENo.Michael
0839Kozlowski rey P No58544son Adam K
PE PE No.Murray7457PE No.77769311
75322 Ply:2 SEQN:17524/T17/FLAT •
Sherman Res. Qty: 1 FROM: DRW:
FG02 Wgt:86.8 lbs ... / ... 06/06/2018
2'10"7I 5,5,.1 { 8'3"8
FH
2'10"7 2'6"11 2'10"7
1II (4 III (4
A=4X8 .4X8D
T �/ w1
_ w1 \
1 ❑ 81"2
H =3X8 =4X8 E O
III 3X4 1113X4
i 8.3"8 1
2'8"3 2'11"3 2'8"3
E" H2'8"3 5'7"5 I 8'3"8
Loading Criteria(par) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs)
TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W
TCDL: 17.00 Speed:NA mph Pf:NA Ce:NA VERT(LL): 0.026 B 999 480 H 1599 /- /- /- /- /3.5
BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.112 B 999 360 E 1420 /- /- /- /- /3.5
BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.006 A - - H Min Brg Width Req= 1.5
Des Ld: 62.00 EXP:NA HORZ(TL): 0.017 A - - E Min Brg Width Req= 1.5
NCBCLL:10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:2.0 Bearings H&E are a rigid surface.
Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2017 RES Max TC CSI: 0.569
Load Duration:1.00 BCDL:NA psf TPI Std: 2014 Max BC CSI: 0.618 Maximum Top Chord Forces Per Ply(lbs)
Spacing:24.0" MWFRS Parallel Dist:NA Rep Factors Used:No Max Web CSI:0.711 Chords Tens.Comp. Chords Tens. Comp.
C&C Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: A-B 0 -1437 C-D 0 -1440
I:NA GCpi:NA Plate Type(s): B-C 0 -1513
Wind Duration:NA WAVE VIEW Ver:18.01.00.0323.07
Lumber Purlins Maximum Bot Chord Forces Per Ply(lbs)
Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins Chords Tens.Comp. Chords Tens. Comp.
Top chord 2x4 SP#2 to laterally brace chords as follows: H-G 73 0 F-E 50 0
Bot chord 2x4 SP#2 Chord Spacing(in oc) Start(ft) End(ft) G-F 1513 0
Webs 2x4 SP#3:W1 2x6 SP#2: TC 24 0.00 8.29
BC 99 0.00 8.29
Lumber value set"13B"uses design values Apply purlins to any chords above or below fillers Maximum Web Forces Per Ply(lbs)
approved 1/30/2013 by ALSC at 24"OC unless shown otherwise above. Webs Tens.Comp. Webs Tens. Comp.
Nailnote The TC of this truss shall be braced with attached A-H 0 -767 C-F 0 526
spans at 24"oc in lieu of structural sheathing.
Nail Schedule:0.131"x3",min.nails A-G 1463 0 F-D 1493 0
Top Chord:1 Row @ 5.50"o.c. G-B 0 -552 D-E 0 -691
Bot Chord:1 Row @12.00"o.c.
Webs :1 Row @ 4"o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
Special Loads
---(Lumber Dur.Fac.=1.00/Plate Dur.Fac=1.00)
TC:From 249 plf at 0.00 to 249 plf at 8.29
BC:From 10 plf at 0.00 to 10 plf at 8.29
TC: 275 lb Conc.Load at 1.25
TC: 224 lb Conc.Load at 3.25
TC: 373 lb Conc.Load at 4.83
Plating Notes
Plate positions consider a 0.50 inch truss perimeter
edge distance.
Additional Notes
Truss must be installed as shown with top chord up.
The overall height of this truss excluding overhang is
1-4-0.
NOTES:
f 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
(911'11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer iqW\
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
Tru eHouse PE Noel 60839 Kozlowski Jeffrey
No.58544son
o58544son pE No.71457y PE No.Russet
" 75322 Ply:1 SEAN:17522/T33/SY42
Sherman Res. Qty: 1 FROM: DRW:
FGE01 Wgt:100.8 lbs ... / ... 06/06/2018
1'4"8
1-1-1'4"—I
(TYP)
W=3X4
A B C D E F G H I J K L M N 0 P
- AHJ 0
c
1 ���/�/ / /�� �/ �� / R 8'1"2 1„2
AG AF AE AD AC AB AA Z Y X W V U T S 1113X3
IA 3X3 W=3X4
I- 19'
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Prin PSF) DefUCSI Criteria ♦Maximum Reactions(lbs),or'=PLF
TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W
TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.000 P 999 480 AG"98 /- /- /- /- /228
BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.001 P 999 360 AG Min Brg Width Req= -
BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL):-0.000 R - - Bearing AG is a rigid surface.
Des Ld: 62.00 EXP:NA HORZ(TL):0.000 R - -
NCBCLL:10.00 Mean Height:NA ft Code I Misc Criteria Creep Factor:2.0 Maximum Top Chord Forces Per Ply(lbs)
Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2017 RES Max TC CSI: 0.169 Chords Tens.Comp. Chords Tens. Comp.
Load Duration:1.00 BCDL:NA psf TPI Std: 2014 Max BC CSI: 0.026 A-B 0 0 I-J 0 0
Spacing:19.2" MW FRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI:0.030 B-C 0 0 J-K 0 0
CBC Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber. C-D 0 0 K-L 0 0
I:NA GCpi:NA Plate Type(s): D-E 0 0 L-M 0 0
Wind Duration:NA WAVE VIEW Ver:18.01.00B.0430.21 E-F 0 0 M-N 0 0
Lumber End Vertical Attachment F-G 0 0 N-O 0 0
Value Set 13B(Effective 6/1/2013) Attach notched end vertical(s)to next end vertical H-I 0 0 O-P 0 0
Top chord 4x2 SP#3 using(3)qty.10d box or(0.128"x3"min)gun nails,or H- 0 0
Bot chord 4x2 SP#3 (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire
Webs 4x2 SP#3 staples,through wide face;or(3)qty.16-Gauge,1" Maximum Bot Chord Forces Per Ply(lbs)
Crown(minimum),1-1/2"length wire staples on each Chords Tens.Comp. Chords Tens. Comp.
Lumber value set"13B"uses design values narrow face.
approved 1/30/2013 by ALSC AG-AF 0 0 Y-X 0 0
Additional Notes AF-AE 0 0 X-W 0 0
Bracing Truss must be installed as shown with top chord up. AE-AD 0 0 W-V 0 0
Sheathing is required for any longitudinal(drag) The overall height of this truss excluding overhang is AD-AC 0 0 V-U 0 0
forces.All connections to be designed by the building 1 0 AC-AB 0 0 U-T 0 0
designer. AB-AA 0 0 T-S 0 0
Fasten rated sheathing to one face of this frame. AA-Z 0 0 S-R 0 0
Z-Y 0 0
Plating Notes
All plates are 1.5X3 except as noted. Maximum Web Forces Per Ply(lbs)
Webs Tens.Comp. Webs Tens. Comp.
Purlins
In lieu of structural panels or rigid ceiling use purlins AH-AG 0 8 P-R 0 50
to laterally brace chords as follows: A-AG 0 -50 R-0 0 -8
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 0.25 18.75 Maximum Gable Forces Per Ply(lbs)
BC 120 0.25 18.75
Apply purlins to any chords above or below fillers Gables Tens.Comp. Gables Tens. Comp.
at 24"OC unless shown otherwise above. B-AF 0 -132 J-X 0 -122
Loading C-AE 0 -119 K-W 0 -122
D-AD 0 -122 L-V 0 -121
Bottom chord checked for 10.00 psf non-concurrent E-AC 0 -121 M-U 0 -122
live load. F-AB 0 -122 N-T 0 -119
G-AA 0 -122 O-S 0 -132
H-Y 0 -122
NOTES:
Nor- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
(TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer ig*/\
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
-� APEX
TrueHouse PMichaNoel 0839owskiFErNo 58544meson FE No.71457y Adam K PE No.7Russell
693
75322 Ply:1 SEQN:17433/T31/SY42 •
Sherman Res. Qty: 1 FROM: DRW:
FGE02 Wgt:54.6 lbs ... / ... 06/06/2018
12 H 1'4" H
(TYP)
A B C D E F G H I
T - - - - - - - -
J 3T8
"v
1 – -- – – _---"l – – – — 8'1"2
S / R/ /O / 3
1 9'11"8 1
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Def/CSI Criteria ♦Maximum Reactions(lbs),or'=PLF
TCLL: 40.00 Wind Std: NA Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W
TCDL: 17.00 Speed: NA mph Pf:NA Ce:NA VERT(LL): 0.000 G 999 480 K. 98 /_ /- /- /- /119
BCLL: 0.00 Enclosure:NA Lu:NA Cs:NA VERT(TL): 0.000 G 999 360 K Min Brg Width Req= -
BCDL: 5.00 Category:NA Snow Duration:NA HORZ(LL): 0.000 I - - Bearing S is a rigid surface.
Des Ld: 62.00 EXP:NA HORZ(TL):0.001 I - -
NCBCLL:10.00 Mean Height:NA ft Code/Misc Criteria Creep Factor:2.0 Maximum Top Chord Forces Per Ply(lbs)
Soffit: 0.00 TCDL:NA psf Bldg Code: FBC 2017 RES Max TC CSI: 0.075 Chords Tens.Comp. Chords Tens. Comp.
Load Duration:1.00 BCDL:NA psi TPI Std: 2014 Max BC CSI: 0.016 A-B 0 0 E-F 0 0
Spacing:19.2" MW FRS Parallel Dist:NA Rep Factors Used:Yes Max Web CSI:0.029 B-C 0 0 F-G 0 0
CBC Dist a:NA ft FT/RT:30(0)/10(0) Mfg Specified Camber: C-D 0 0 G-H 0 0
I:NA GCpi:NA Plate Type(s): D-E 0 0 H-I 0 0
Wind Duration:NA WAVE VIEW Ver:18.01.00B.0430.21
Lumber End Vertical Attachment Maximum Bot Chord Forces Per Ply(lbs)
Value Set:13B(Effective 6/1/2013) Attach notched end vertical(s)to next end vertical Chords Tens.Comp. Chords Tens. Comp.
Top chord 4x2 SP#2 using(3)qty.10d box or(0.128"x3"min)gun nails,or S-R 0 0 O-N 0 0
Bot chord 4x2 SP#2 (5)qty. 15-Gauge,7/16"Crown,2-1/2"length wire R-Q 0 0 N-M 0 0
Webs 4x2 SP#3 staples,through wide face;or(3)qty.16-Gauge,1"
Crown(minimum),1-1/2"length wire staples on each Q-P 0 0 M-L 0 0
Lumber value set"13B"uses design values narrow face. P-0 0 0 L-K 0 0
approved 1/30/2013 by ALSC
Additional Notes Maximum Web Forces Per Ply(lbs)
Bracing
Truss must be installed as shown with top chord up. Webs Tens.Comp. Webs Tens. Comp.
Sheathing is required for any longitudinal(drag) The overall height of this truss excludingoverhangis
forces.All connections to be designed by the building 9 A-S 0 -32 K-J 0 -7
designer. 1-4-0I-K 0 -26
Fasten rated sheathing to one face of this frame.
Maximum Gable Forces Per Ply(lbs)
Plating Notes Gables Tens.Comp. Gables Tens. Comp.
All plates are 1.5X3 except as noted. B-R 0 -116 F-N 0 -121
Purlins C-Q 0 -123 G-M 0 -125
In lieu of structural panels or rigid ceiling use purlins D-P 0 -121 H-L 0 105
to laterally brace chords as follows: E-0 0 -122
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 0.00 9.71
BC 116 0.00 9.71
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent
live load.
NOTES:
r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
(ril'H) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer I#V\
Business No.7547-4745 Sutton Park Court.Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
Tru eHo use Michael 0 Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell
PE No.60839 PE No.58544 PE No.71457 PE No.77693
75322 Ply:1 SEQN:17430/T5/HIP_
Sherman Res. Qty:4 FROM: DRW:
HJ01 Wgt:40.6 lbs ... / ... 06/06/2018
5'7" -I 9'9"5
HH
5'7" 4'2"5
2.12 o D
T T O 20'4"5
=3X40 co
b
_� PP
0
3X4(A1T) B N CDN
-,-
t•I
a1'z A _ t, I O 18'7"
E F 1I
4X4(")
-2'9"15 I- 9'6"13 18
I
9'6"13 9'9"5
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Def ICSI Criteria ♦Maximum Reactions(lbs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W
TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.040 C 999 240 G 510 /255 /- /- /- /4.2
BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.086 C 999 180 E 247 /81 /- /- /- /1.5
BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.008 F - - D 210 /166 /- /- /- /1.5
Des Ld: 32.00 EXP:D - HORZ(TL):0.012 F - - Wind reactions based on MWFRS
NCBCLL:0.00 Mean Height:19.54 ft Code I Misc Criteria Creep Factor:2.0 G Min Brg Width Req= 1.5
Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.581 E Min Brg Width Req= -
Load Duration:1.25 BCDL:3.0 psf TPI Std:2014 Max BC CSI: 0.968 D Min Brg Width Req= -
g MWFRS Parallel Dist:0 to h/2 RepFactors Used:Yes Max Web CSI:0.381 Bearing G is a rigid surface.
Spacing:24.0"
C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber:
GCpi:0.18 Plate Type(s): Maximum Top Chord Forces Per Ply(lbs)
Wind Duration:1.60 WAVE VIEW Ver:18.01.00.0323.07 Chords Tens.Comp. Chords Tens. Comp.
Lumber Additional Notes A-B 29 17 C-D 37 37
Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is B-C 517 -792
Top chord 2x4 SP#1 2-0-13. Maximum Bot Chord Forces Per Pty(lbs)
Bot chord 2x4 SP#2
Webs 2x4 SP#3 Chords Tens.Comp. Chords Tens. Comp.
Lumber value set"13B"uses design values B-F 767 -495 F-E 0 0
approved 1/30/2013 by ALSC
Plating Notes Maximum Web Forces Per Ply(lbs)
(")1 plate(s)require special positioning.Refer to Webs Tens.Comp.
scaled plate plot details for special positioning C-F 510 -791
requirements.
Plate positions consider a 0.50 inch truss perimeter
edge distance.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 -2.83 9.77
BC 94 0.15 9.77
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
Loading
Hipjack supports 6-10-15 setback jacks with no webs.
Truss designed for unbalanced load using 0.00/1.00
windward/leeward factors.
Wind
Wind loads and reactions based on MW FRS.
NOTES:
IC 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03.
should be used in conjunction with the architectural plans during installation.
(11'14) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
urraTru eHo u se PE No.Michael
6083g Kozlowski effrey P PB No. 8544son Derek BpE No.7145 y Adam K
PE No.7 69311
APEX
75322 Ply:1 SEAN:17463/T16/HIP_
Sherman Res. Qty: 1 FROM: DRW:
HJO1A Wgt:35.0 lbs ... / ... 06/06/2018
4'10"5 9'9"5
FH
4'10"5 I 411"
2.12 0
T 20'4"5
1113X40 T M
3X4(A1T) B �� HB4'9"4 m N N
4,,2 A_ 1 i 118,7„
(f 'F E
1113X4
1 4'10"5
-2,9"15 -I- 4'10"5 I 4'11" H
4'10"5 9'9"5
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W
TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):-0.019 F 999 240 G 370 /158 /- /- /- /3.5
BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):-0.041 F 999 180 F 373 /196 /- /- /- /4.9
BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL):-0.005 F - - E 45 /- /20 /- /- /1.5
Des Ld: 32.00 EXP:D HORZ(TL):0.007 F - - D 223 /168 /- /- /- /1.5
NCBCLL:0.00 Mean Height:19.54 ft Code/Misc Criteria Creep Factor:2.0 Wind reactions based on MWFRS
Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.306 G Min Brg Width Req= 1.5
Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.205 F Min Brg Width Req= 1.5
Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI:0.120 E Min Brg Width Req= -
C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: D Min Brg Width Req=
Bearings G&F are a rigid surface.
GCpi:0.18 Plate Type(s):
Wind Duration:1.60 WAVE VIEW Ver:18.01.00.0323.07 Maximum Top Chord Forces Per Ply(lbs)
Lumber Chords Tens.Comp. Chords Tens. Comp.
Value Set:13B(Effective 6/1/2013) A-B 29 -17 C-D 39 -41
Top chord 2x4 SP M-31 B-C 43 -29
Bot chord 2x4 SP#2
Webs 2x4 SP#3
Maximum Bot Chord Forces Per Ply(lbs)
Lumber value set"13B"uses design values
approved 1/30/2013 by ALSC Chords Tens.Comp. Chords Tens. Comp.
B-F 14 -25 F-E 0 0
Plating Notes
Plate positions consider a 0.50 inch truss perimeter Maximum Web Forces Per Ply(lbs)
edge distance. Webs Tens.Comp.
Purlins C-F 263 -342
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 -2.83 9.77
BC 75 0.15 9.77
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
Loading
Hipjack supports 6-10-15 setback jacks with no webs.
Truss designed for unbalanced load using 0.00/1.00
windward/leeward factors.
Wind
Wind loads and reactions based on MW FRS.
Additional Notes
The overall height of this truss excluding overhang is
2-0-13.
NOTES:
r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
(1.1'14) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer 11*/\
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
Tru eHo use Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell
PE No.60839 PE No.58544 PE No.71457 PE No.77693
75322 Ply:1 SEAN:17443/T26/HIP_
Sherman Res. Qty: 1 FROM: DRW:
HJO2 Wgt:12.6 lbs ... / ... 06/06/2018
2.12 0
C
3X4(A1 T)
B co ;� 19 '1"13
42 - o
�� gni 18,7„
A _
E = D NI
2'9"15 + 2'11"4
2'11"4
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W
TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA E 356 /334 /213 /- /62 /4.2
BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 29 /24 /51 /- /- /1.5
BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.003 D - - C 61 /32 /26 /- /- /1.5
Des Ld: 32.00 EXP:D HORZ(TL):0.003 D - - Wind reactions based on MWFRS
NCBCLL:10.00 Mean Height:18.94 ft Code/Misc Criteria Creep Factor:2.0 E Min Brg Width Req= 1.5
Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.949 D Min Brg Width Req= -
Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.324 C Min Brg Width Req= -
MWFRS Parallel Dist:0 to h/2 RepFactors Used:Yes Max Web CSI:0.000 Bearing E is a rigid surface.
Spacing:24.0"
C&C Dist a:3.00 ft FT/RT:30(0)!10(0) Mfg Specified Camber.
GCpi:0.18 Plate Type(s): Maximum Top Chord Forces Per Ply(lbs)
Chords Tens.Comp. Chords Tens. Comp.
Wind Duration:1.60 WAVE VIEW Ver:18.01.00.0323.07
Lumber Additional Notes A-B 29 0 B-C 11 14
Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is
Top chord 2x4 SP#1 0-10-5. Maximum Bot Chord Forces Per Ply(lbs)
Bot chord 2x4 SP#2 Top Chord overhang(s)may be field trimmed. Chords Tens.Comp.
Lumber value set"13B"uses design values B-D 0 0
approved 1/30/2013 by ALSC
Plating Notes
Plate positions consider a 0.50 inch truss perimeter
edge distance.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 -2.83 2.94
BC 34 0.15 2.94
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent
live load.
Truss designed for unbalanced load using 0.00/1.00
windward/leeward factors.
Wind
Wind loads based on MWFRS with additional C&C
member design.
NOTES:
1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
(II"T'H) 2.Apex Technology is a fictitious name owned by Jaz Apex Technology Inc.,Florida Corporation. Florida Engineer fi*/\
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
TrueHouse MichaePE No.60839 Kozlowski
60 39Jeffrey
58544�n
PE Derek PE No.Murray7457Adam l<PE No.Russell 1
693
75322 Ply:1 SEQN:17414/T18/JACK •
Sherman Res. Ory: 10 FROM: DRW:
J01 Wgt:8.4 lbs ... / ... 06/06/2018
12
3 L
C
3X4(**) B ' N t gni 18'11"10
CO „ 18'7"
A .. \I
E � D
i
1'4"
H 2' + 1 torr H
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W
TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA E 278 /242 /175 /- /46 /3.5
BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 16 /35 /48 /- /- /1.5
BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.001 D - - C 22 /41 /57 /- /- /1.5
Des Ld: 32.00 EXP:D HORZ(TL):0.001 D - - Wind reactions based on MWFRS
NCBCLL:10.00 Mean Height:18.84 ft Code/Misc Criteria Creep Factor:2.0 E Min Brg Width Req= 1.5
Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.622 D Min Brg Width Req= -
Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.085 C Min Brg Width Req= -
Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI:0.000 Bearing E is a rigid surface.
C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs)
GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp.
Wind Duration:1.60 WAVE VIEW Ver:18.01.00.0323.07
Lumber Additional Notes A-B 28 0 B-C 37 -15
Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is Maximum Bot Chord Forces Per Plylbs
Top chord 2x4 SP#2 0-8-2. (lbs)
Bot chord 2x4 SP#2 Top Chord overhang(s)may be field trimmed. Chords Tens.Comp.
Lumber value set"136"uses design values B-D 0 0
approved 1/30/2013 by ALSC
Plating Notes
("`)1 plate(s)require special positioning.Refer to
scaled plate plot details for special positioning
requirements.
Plate positions consider a 0.50 inch truss perimeter
edge distance.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 -2.00 1.33
BC 14 0.15 1.33
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent
live load.
Truss designed for unbalanced load using 0.00/1.00
windward/leeward factors.
Wind
Wind loads based on MWFRS with additional C&C
member design.
NOTES:
f
(TH 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include SCSI 1-03,
should be used in conjunction with the architectural plans during installation. i�
2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
TrueHouse PE Michael 39 PE No 5
Kozlowski Jeffrey PE No. Murray1457PE No.77769311
75322 Ply:1 SEQN:17415/T6/JACK
Sherman Res. Qty: 10 FROM: DRW:
J02 Wgt:12.6 lbs ... / ... 06/06/2018
12
3
19'4"10
3X4(**) B
42 MM
� � (1) 18,7
A rr
E
3'
2' + 3' H
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W
TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA E 266 /198 /152 /- /64 /3.5
BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 31 /9 /25 /- /- /1.5
BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.002 D - - C 65 /35 /18 /- /- /1.5
Des Ld: 32.00 EXP:D HORZ(TL):0.002 D - - Wind reactions based on MW FRS
NCBCLL:10.00 Mean Height:19.05 ft Code/Mist Criteria Creep Factor:2.0 E Min Brg Width Req= 1.5
Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.358 D Min Brg Width Req= -
Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.095 C Min Brg Width Req= -
Spacing:24.0" MW FRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI:0.000 Bearing E is a rigid surface.
C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs)
GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp.
Wind Duration:1.60 WAVE VIEW Ver:18.01.00.0323.07
Lumber Additional Notes A-B 28 0 B-C 16 24
Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is
Top chord 2x4 SP#2 1-1-2. Maximum Bot Chord Forces Per Ply(lbs)
Bot chord 2x4 SP#2 Top Chord overhang(s)may be field trimmed. Chords Tens.Comp.
Lumber value set"13B"uses design values B-D 0 0
approved 1/30/2013 by ALSC
Plating Notes
(")1 plate(s)require special positioning.Refer to
scaled plate plot details for special positioning
requirements.
Plate positions consider a 0.50 inch truss perimeter
edge distance.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 -2.00 3.00
BC 34 0.15 3.00
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent
live load.
Truss designed for unbalanced load using 0.00/1.00
windward/leeward factors.
Wind
Wind loads based on MW FRS with additional C&C
member design.
NOTES:
r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
(j11t)
2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
TrueHouse MichaeG
PE No.l 60839 Kozlowski Jeffrey
No.58544 on PE No.MurrayDerek B7457Adam K Russe
PE No.77769311
APEX
75322 Ply:1 SEQN:17416/T4/JACK
Sherman Res. Qty:8 FROM: DRW:
J03 Wgt:18.2 lbs ... / ... 06/06/2018
3 C
� T 19'10"10
N
O
3X4(**) B
4!'2A XI
18'7n
E
5'
2'
5'
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udell U# Loc R /U /Rw /Rh /RL /W
TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA E 311 /205 /164 /- /85 /3.5
BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 63 /- /25 /- /- /1.5
BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.006 D - - C 114 /79 /34 /- /- /1.5
Des Ld: 32.00 EXP:D HORZ(TL): 0.010 D - - Wind reactions based on MWFRS
NCBCLL:10.00 Mean Height:19.30 ft Code/Misc Criteria Creep Factor:2.0 E Min Brg Width Req= 1.5
Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.385 D Min Brg Width Req= -
Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.179 C Min Brg Width Req= -
MWFRS Parallel Dist:0 to h/2 RepFactors Used:Yes Max Web CSI:0.000 Bearing E is a rigid surface.Spacing:24.0"
C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Maximum Top Chord Forces Per Ply(lbs)
GCpi:0.18 Plate Type(s): Chords Tens.Camp. Chords Tens. Comp.
Wind Duration:1.60 WAVE VIEW Ver:18.01.00.0323.07
Lumber Additional Notes A-B 28 0 B-C 28 46
Value Set:138(Effective 6/1/2013) The overall height of this truss excluding overhang is
Top chord 2x4 SP#2 1-7-2. Maximum Bot Chord Forces Per Ply(lbs)
Bot chord 2x4 SP#2 Top Chord overhang(s)may be field trimmed. Chords Tens.Comp.
Lumber value set"13B"uses design values B-D 0 0
approved 1/30/2013 by ALSC
Plating Notes
(**)1 plate(s)require special positioning.Refer to
scaled plate plot details for special positioning
requirements.
Plate positions consider a 0.50 inch truss perimeter
edge distance.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 -2.00 5.00
BC 58 0.15 5.00
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent
live load.
Truss designed for unbalanced load using 0.00/1.00
windward/leeward factors.
Wind
Wind loads based on MWFRS with additional C&C
member design.
NOTES:
1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation. �\
(1114'H) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer %�-
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
Tru eHo use Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell
PE No.60839 PE No.58544 PE No.71457 PE No.77693
" 75322 Ply:1 SEON:17457/T22/JACK
Sherman Res. Qty: 1 FROM: DRW:
JO3A Wgt:19.6 lbs ... / ... 06/06/2018
I- 3'5"12 I 5'
_I
3'5"12 1'6'4
3 D
III3X4C : IT
3X4(.. g : HB 1'4"8 M N o
o
IN
A _� A__.
I icsi 18'7"
/III �F E
III 3X4
r 3'5"12 i
3'5'121'6"4
I--2 I 3,5„12 I 5' "I
'-
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Def/CSI Criteria ♦Maximum Reactions(lbs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl L/# Loc R /U /Rw /Rh /RL /W
TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.005 F 999 240 B 269 /196 /153 /- /85 /3.0
BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.011 F 999 180 F 224 /74 /81 /- /- /3.5
BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.002 F - - E 5 /10 /11 /- /- /1.5
Des Ld: 32.00 EXP:D HORZ(TL):0.002 F - - D 30 /20 /10 /- /- /1.5
NCBCLL:10.00 Mean Height:19.30 ft Code/Misc Criteria Creep Factor:2.0 Wind reactions based on MWFRS
Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.359 B Min Brg Width Req= 1.5
Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.085 F Min Brg Width Req= 1.5
-
Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI:0.062 E Min Brg Width Req=
D Min Brg Width Req= -
C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber. Bearings B&F are a rigid surface.
GCpi:0.18 Plate Type(s):
Wind Duration:1.60 WAVE VIEW Ver:18.01.00.0323.07 Maximum Top Chord Forces Per Ply(lbs)
Lumber Additional Notes Chords Tens.Comp. Chords Tens. Comp.
Value Set:13B(Effective 6/1/2013) Shim all supports to solid bearing. A-B 28 0 C-D 7 -17
Top chord 2x4 SP#2 The overall height of this truss excluding overhang is B-C 19 -62
Bot chord 2x4 SP#2 1-7-2.
Webs 2x4 SP#3 TopChord overhang(s)maybe field trimmed.
9( ) Maximum Bot Chord Forces Per Ply(lbs)
Lumber value set"13B"uses design values Chords Tens.Comp. Chords Tens. Comp.
approved 1/30/2013 by ALSC
B-F 4 -2 F-E 0 0
Plating Notes
(")1 plate(s)require special positioning.Refer to Maximum Web Forces Per Ply(lbs)
scaled plate plot details for special positioning Webs Tens.Comp.
requirements.
Plate positions consider a 0.50 inch truss perimeter C-F 195 -163
edge distance.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 -2.00 5.00
BC 59 0.13 5.00
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent
live load.
Truss designed for unbalanced load using 0.00/1.00
windward/leeward factors.
Wind
Wind loads based on MW FRS with additional C&C
member design.
NOTES:
r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
(TH) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
Tru eHo use Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell
PE No.60839 PE No.58544 PE No.71457 PE No.77693
75322 Ply:1 SEQN:17454/T20/JACK
Sherman Res. Qty: 1 FROM: DRW:
JO3B Wgt:15.4 lbs ... / ... • 06/06/2018
3 12
Lr B
19'10"10
3X4(**)A
► X / 18.7.,
D C
�- 5'
5'
5'1"8
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg.Pf in PSF) Def/CSI Criteria ♦Maximum Reactions(lbs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W
TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA D 161 /78 /64 /- /62 /1.5
BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA C 69 /7 /28 /- /- /1.5
BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.007 C - - B 117 /89 /37 /- /- /1.5
Des Ld: 32.00 EXP:D HORZ(TL):0.011 C - - Wind reactions based on MWFRS
NCBCLL:10.00 Mean Height:19.55 ft Code/Misc Criteria Creep Factor:2.0
Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.296 Maximum Top Chord Forces Per Ply(lbs)
Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.213 Chords Tens.Comp.
Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI:0.000 A-B 28 -49
C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber:
GCpi:0.18 Plate Type(s): Maximum Bot Chord Forces Per Ply(lbs)
Wind Duration:1.60 WAVE VIEW Ver:18.01.00.0323.07 Chords Tens.Comp.
Lumber Additional Notes
A-C 0 0
Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is
Top chord 2x4 SP#2 1-7-2.
Bot chord 2x4 SP#2
Lumber value set"13B"uses design values
approved 1/30/2013 by ALSC
Plating Notes
(")1 plate(s)require special positioning.Refer to
scaled plate plot details for special positioning
requirements.
Plate positions consider a 0.50 inch truss perimeter
edge distance.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 0.00 5.00
BC 60 0.00 5.00
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent
live load.
Truss designed for unbalanced load using 0.00/1.00
windward/leeward factors.
Wind
Wind loads based on MWFRS with additional C&C
member design.
NOTES:
r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
(Pr'11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
Tru eHo u se Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell
PE No.60839 PE No.58544 PE No.71457 PE No.77693
75322 Ply:1 SEAN:17417/T8/EJAC
Sherman Res. Qty: 11 FROM: DRW:
J04 Wgt:25.2 lbs ... / ... 06/06/2018
C
3 `�2
V 20'4"10
T
N
O
3X4(**) BI
N iv
1-421)-18'7"
E D
2' I 7'
-I
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W
TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL):NA E 367 /223 /184 /- /108 /3.5
BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA D 92 /0 /36 /- /- /1.5
BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.017 D - - C 163 /121 /50 /- /- /1.5
Des Ld: 32.00 EXP:D HORZ(TL):0.027 D - - Wind reactions based on MWFRS
NCBCLL:10.00 Mean Height:19.55 ft Code/Misc Criteria Creep Factor:2.0 E Min Brg Width Req= 1.5
Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.612 D Min Brg Width Req= -
Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.415 C Min Brg Width Req= -
Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI: 0.000 Bearing E is a rigid surface.
C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber:
GCpi:0.18 Plate Type(s): Maximum Top Chord Forces Per Ply(Ibs)
Wind Duration:1.60 WAVE VIEW Ver:18.01.00.0323.07
Chords Tens.Comp. Chords Tens. Comp.
Lumber Additional Notes A-B 28 0 B-C 40 -61
Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is
Top chord 2x4 SP#2 2-1-2. Maximum Bot Chord Forces Per Ply(Ibs)
Bot chord 2x4 SP#2 Top Chord overhang(s)may be field trimmed. Chords Tens.Comp.
Lumber value set"13B"uses design values B-D 0 0
approved 1/30/2013 by ALSC
Plating Notes
(")1 plate(s)require special positioning.Refer to
scaled plate plot details for special positioning
requirements.
Plate positions consider a 0.50 inch truss perimeter
edge distance.
Purlins •
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 -2.00 7.00
BC 75 0.15 7.00
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent
live load.
Truss designed for unbalanced load using 0.00/1.00
windward/leeward factors.
Wind
Wind loads based on MW FRS with additional C&C
member design.
NOTES:
r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
(11'11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
Tru eHo u se Michael S Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell APEX
PE No.60839 PE No.58544 PE No.71457 PE No.77693
75322 Ply:1 SEQN:17460/T24/EJAC •
Sherman Res. Qty: 1 FROM: DRW:
JO4A Wgt:26.6 lbs ... / ... 06/06/2018
3,5"12 I 7
I
3'5"12 3'6"4
ID
12
3 L__.-- T T20'4"10
I--
1113X4 CI
O N
O
. `
3X4(")B
se HB 3'4"8 -in `" io
I1I187
„
II 'F E
113 4
3'5"12 1
3'5"12 3'6"4
2' I 3'S"12 F' 7' H
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pt in PSF) Defl!CSI Criteria ♦Maximum Reactions(lbs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W
TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.005 F 999 240 B 266 /185 /148 /- /107 /3.0
BOLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.012 F 999 180 F 274 /108 /104 /- /- /3.5
BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.002 F - - E 40 /- /15 /- I- /1.5
Des Ld: 32.00 EXP:D HORZ(TL):0.002 F - - D 78 /52 /23 /- /- /1.5
NCBCLL:10.00 Mean Height:19.55 ft Code I Misc Criteria Creep Factor:2.0 Wind reactions based on MWFRS
Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.386 B Min Brg Width Req= 1.5
Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.110 F Min Brg Width Req= 1.5
MWFRS Parallel Dist:h/2 to h RepFactors Used:Yes Max Web CSI:0.083 E Min Brg Width Req= -
Spacing:24.0" D Min Brg Width Req= -
C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Bearings B&F are a rigid surface.
GCpi:0.18 Plate Type(s):
Wind Duration:1.60 WAVE VIEW Ver.18.01.00.0323.07 Maximum Top Chord Forces Per Ply(lbs)
Lumber Additional Notes Chords Tens.Comp. Chords Tens. Comp.
Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is A-B 28 0 C-D 19 -35
Top chord 2x4 SP#2 2-1-2. B-C 24 -99
Bot chord 2x4 SP#2 Top Chord overhang(s)may be field trimmed.
Webs 2x4 SP#3
Maximum Bot Chord Forces Per Ply(lbs)
Lumber value set"13B"uses design values
approved 1/30/2013 by ALSC Chords Tens.Comp. Chords Tens. Comp.
B-F 7 -5 F-E 0 0
Plating Notes
(")1 plate(s)require special positioning.Refer to Maximum Web Forces Per Ply(lbs)
scaled plate plot details for special positioning Webs Tens.Comp.
requirements.
Plate positions consider a 0.50 inch truss perimeter C-F 222 -217
edge distance.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 -2.00 7.00
BC 75 0.13 7.00
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent
live load.
Truss designed for unbalanced load using 0.00/1.00
windward/leeward factors.
Wind
Wind loads based on MWFRS with additional C&C
member design.
NOTES:
N-
61-}
1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
TH 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc..Florida Corporation. Florida Engineer
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
Tru eHo use Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell
PE No.60839 PE No.58544 PE No.71457 PE No.77693
75322 Ply:1 SEAN:17470/T9/MONO
Sherman Res. Qty: 1 FROM: DRW:
J05 Wgt:35.0 lbs ... / ... 06/06/2018
12
3 1113X4(** B
- 1
N
3X4(A1)A
I■
miligimummimmiimaffim
�( 18'7"
p
1114X5*)
7'
7'
7'
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Def/CSI Criteria ♦Maximum Reactions(lbs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W
TCDL: 7.00 Speed: 130 mph Pt NA Ce:NA VERT(LL):NA D 561 /306 /- /- /- /3.5
BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL):NA C 825 /412 /- /- /- /-
BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.024 C - - Wind reactions based on MWFRS
Des Ld: 32.00 EXP:D HORZ(TL):0.037 C - - D Min Brg Width Req= 1.5
NCBCLL: 10.00 Mean Height:19.80 ft Code/Misc Criteria Creep Factor:2.0 C Min Brg Width Req= -
Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.634 Bearing D is a rigid surface.
Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.543
Spacing:24.0' MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI:0.182 Maximum Top Chord Forces Per Ply(lbs)
C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber. Chords Tens.Comp.
GCpi:0.18 Plate Type(s): A-B 58 -87
Wind Duration:1.60 WAVE VIEW Ver.18.01.00.0323.07
Lumber Hangers/Ties Maximum Bot Chord Forces Per Ply(lbs)
Value Set 13B(Effective 6/1/2013) (J)Hanger Support Required,by others Chords Tens.Comp.
Top chord 2x4 SP#2 A-C 56 -31
Bot chord 2x6 SP SS Dense Loading
Webs 2x4 SP#3 Bottom chord checked for 10.00 psf non-concurrent Maximum Web Forces Per Ply(lbs)
Lumber value set"13B"uses design values live load. Webs Tens.Comp.
approved 1/30/2013 by ALSC
Wind B-C 112 -157
Special Loads Wind loads and reactions based on MWFRS.
--(Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) Right end vertical not exposed to wind pressure.
TC:From 54 plf at 0.00 to 54 plf at 7.00
BC:From 5 plf at 0.00 to 5 plf at 7.00 Additional Notes
BC: 161 Ib Conc.Load at 1.82 The overall height of this truss excluding overhang is
BC: 262 Ib Conc.Load at 3.73 2-1-2
BC: 547 lb Conc.Load at 5.73
Plating Notes
(")2 plate(s)require special positioning.Refer to
scaled plate plot details for special positioning
requirements.
Plate positions consider a 0.50 inch truss perimeter
edge distance.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 0.00 7.00
BC 82 0.15 7.00
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
NOTES:
f' 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
(911'14) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer 11*/\
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
Tru eHo use PL Noel 0839 owski Jeffrey
PE No.58544son PE No.Murray7457PE No.7 69311
75322 Ply:1 SEAN:17440/T19/HIPS •
Sherman Res. Qty: 1 FROM: DRW:
T01 Wgt:148.4 lbs ... / ... 06/06/2018
I^'I2♦ '-I
4'10"9 7' 16" 11'6" 14'6" 1T6" 19' 717 26'
I 4,10"9 I 2'1"7 I I 3' I 3' I 3' I 1'6" I I 4'10"9 I
3 p =H0510("")=3X4 =3X4 T2 m3X4=H0510(")
D E F G_3X4 H I
T �3X4C i� = -i `- - Orr J 3X4 T
`" 4X5(,. �I' \-I -_ `I� 4X5r) o
N m4X5(.. �_ ...-_ \��-_-�: _ Km4X5(-) in
1 7_2 A i 1.� L a (187"
Q P O N M 1
=4X8 m3X4 Le H1010(**) m3X4 =4X8
1 26' A
I-2' I 6'10"4 I 3'1"12 I 3' I 3' I 3'1"12 I 6'10"4 I 2'-I
6'10"4 10' 13' 16' 19'1"12 26'
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DeflICSI Criteria ♦Maximum Reactions(lbs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W
TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.433 0 712 308 R 1734 /949 /- /- /- /3.5
BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.963 0 441 308 S 1734 /949 /- /- /- /3.5
BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.076 M - - Wind reactions based on MWFRS
Des Ld: 32.00 EXP:D HORZ(TL):0.122 M - - R Min Brg Width Req= 1.8
NCBCLL:0.00 Mean Height:19.55 ft Code/Misc Criteria Creep Factor:2.0 S Min Brg Width Req= 1.8
Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.506 Bearings R&S are a rigid surface.
Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.960
Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:No Max Web CSI:0.421 Maximum Top Chord Forces Per Ply(lbs)
C&C Dist a:3.00 ft FT/RT:30(0)11 0(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp.
GCpi:0.18 Plate Type(s): A-B 28 -20 G-H 3505 -6621
Wind Duration:1.60 WAVE,HS VIEW Ver:18.01.00.0323.07 B-C 3001 -5604 H-I 2843 -5378
Lumber C-D 2969-5616 I-J 2969 -5616
Value Set:13B(Effective 6/1/2013) D-E 2843-5378 J-K 3001 -5604
E-F 3505-6621 K-L 28 -20
Top chord 2x4 SP M-31:T2 2x6 SP SS Dense: F-G 3695-6976
Bot chord 2x6 SP SS Dense
Webs 2x4 SP#3
Lumber value set"138"uses design values Maximum Bot Chord Forces Per Ply(lbs)
approved 1/30/2013 by ALSC Chords Tens.Comp, Chords Tens. Comp.
B-Q 5408 -2890 O-N 6959 -3720
Plating Notes Q-P 6156-3284 N-M 6156 -3284
(**)7 plate(s)require special positioning.Refer to P-O 6959-3720 M-K 5408 -2890
scaled plate plot details for special positioning
requirements. Maximum Web Forces Per Ply(lbs)
Plate positions consider a 0.50 inch truss perimeter Webs Tens.Comp. Webs Tens. Comp.
edge distance.
C-Q 75 0 O-G 38 0
Purlins Q-D 1105 -556 G-N 319 -500
In lieu of structural panels or rigid ceiling use purlins Q-E 624-1098 N-H 688 -325
to laterally brace chords as follows: E-P 688 -325 H-M 624 -1098
Chord Spacing(in oc) Start(ft) End(ft) P-F 319 -500 I-M 1105 -556
TC 24 -2.00 28.00 F-O 38 0 M-J 75 0
BC 51 0.15 25.85
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
Loading
#1 hip supports 7-0-0 jacks with no webs.
Wind
Wind loads and reactions based on MWFRS.
Additional Notes
The overall height of this truss excluding overhang is
2-1-2.
NOTES:
f 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03.
should be used in conjunction with the architectural plans during installation.
(11'0 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer figt/\
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
Tru eHo u se PE No.60839
008Koozlowski
Jeffrey
No.58544son PE No.71457y APE No.Russell
75322 Ply:1 SEQN:17427/T1/HIPS
Sherman Res. Qty: 1 FROM: DRW:
T02 Wgt:100.8 I bs ... / ... 06/06/2018
9' 17' 26'
9' 8' 9'
3 v =4X10 $4X8(")
C T2 D
.TT
N C
A
N =4X4(")B E 4X4(") el
1 �Z An 1-43.1-43.-18rl ,a
G F
E 5X5(") --,5X5(-)
1 26' 1
2, 9'1.12 7'6"12 9'3"8
9'1"12 16'8"8 26'
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W
TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.208 F 999 308 H 960 /483 /392 /- /61 /3.5
BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.459 F 926 308 E 838 /360 /332 /- /- /3.5
BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.055 F - - Wind reactions based on MWFRS
Des Ld: 32.00 EXP:D HORZ(TL):0.089 F - - H Min Brg Width Req= 1.5
NCBCLL:10.00 Mean Height:19.80 ft Code/Misc Criteria Creep Factor:2.0 E Min Brg Width Req= 1.5
Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.912 Bearings H 8 E are a rigid surface.
Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.996
Spacing:24.0• MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI:0.492 Maximum Top Chord Forces Per Ply(lbs)
C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp.
GCpi:0.18 Plate Type(s): A-B 28 0 C-D 1409 -2248
Wind Duration:1.60 WAVE VIEW Ver.18.01.00.0323.07 B-C 1408 -2355 D-E 1411 -2352
Lumber Additional Notes
Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is Maximum Bot Chord Forces Per Ply(lbs)
Top chord 2x4 SP#1 :T2 2x4 SP#2:
2-7-2. Chords Tens.Comp. Chords Tens. Comp.
Bot chord 2x4 SP#2 Top Chord overhang(s)may be field trimmed. B-G 2238 -1299 F-E 2236 -1295
Webs 2x4 SP#3 G-F 2245 -1297
Lumber value set"13B"uses design values
approved 1/30/2013 by ALSC Maximum Web Forces Per Ply(lbs)
Plating Notes Webs Tens.Comp. Webs Tens. Comp.
(")5 plate(s)require special positioning.Refer to C-G 247 0 F-D 250 -9
scaled plate plot details for special positioning C-F 418 -399
requirements.
Plate positions consider a 0.50 inch truss perimeter
edge distance.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 -2.00 26.00
BC 71 0.15 25.85
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psi non-concurrent
live load.
Truss designed for unbalanced load using 0.00/1.00
windward/leeward factors.
Wind
Wind loads based on MWFRS with additional C&C
member design.
NOTES:
r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
(11'14) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
Tru eHo use PE Michael
39 owski PE No.5A8544scn PE No.71457y APE No.7 693
75322 Ply:1 SEAN:17425/T3/HIPS -
Sherman Res. Qty: 1 FROM: DRW:
T03 Wgt:114.8 lbs ... ! ... 06/06/2018
53" 96" I 166" I 209" I 26
II
5'3" 4I '3" 7' 4'3" 5'3"
12 m 4 10 w 4 E("")
3 p
T = )
- T
o C
�3X4F_3X4
N
(V N
4X4(..)g _ G-4X4(..) ih
ams A I _4187"
J : 1 H 1
=5X5("") ra5X7("")
1 26' A
I
2 9'6" 6'10"4 97"12
9'6" 16'4"4 � 26'
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W
TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.236 H 999 308 J 960 /479 /389 /- /63 /3.5
BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.524 H 812 308 G 838 /359 /332 /- /- /3.5
BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.060 H - - Wind reactions based on MWFRS
Des Ld: 32.00 EXP:D HORZ(TL):0.096 H - - J Min Brg Width Req= 1.5
NCBCLL:10.00 Mean Height:19.86 ft Code/Misc Criteria Creep Factor:2.0 G Min Brg Width Req= 1.5
Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.721 Bearings J&G are a rigid surface.
Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.999
Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI:0.278 Maximum Top Chord Forces Per Ply(lbs)
C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp.
GCpi:0.18 Plate Type(s): A-B 28 0 D-E 1321 -2115
Wind Duration:1.60 WAVE VIEW Ver:18.01.00.0323.07 B-C 1535-2560 E-F 1331 -2189
Lumber Additional Notes C-D 1339-2197 F-G 1555 -2559
Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is
Top chord 2x4 SP#2 2-8-10. Maximum Bot Chord Forces Per Ply(lbs)
Bot chord 2x4 SP#2 Top Chord overhang(s)may be field trimmed. Chords Tens.Comp. Chords Tens. Comp.
Webs 2x4 SP#3 B-I 2455-1442 H-G 2454 -1459
Lumber value set"13B"uses design values I-H 2112-1212
approved 1/30/2013 by ALSC
Plating Notes Maximum Web Forces Per Ply(lbs)
Webs Tens.Comp. Webs Tens. Comp.
("')5 plate(s)require special positioning.Refer to
scaled plate plot details for special positioning C-I 240 -428 H-E 281 -43
requirements. D-I 273 -19 H-F 281 -401
Plate positions consider a 0.50 inch truss perimeter D-H 301 -288
edge distance.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 -2.00 26.00
BC 69 0.15 25.85
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent
live load.
Truss designed for unbalanced load using 0.00/1.00
windward/leeward factors.
Wind
Wind loads based on MW FRS with additional C&C
member design.
NOTES:
f 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
(Trli) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer ift/\
Business No.7547.4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224.904.821.5200
APEX
Tru eHo use Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell
PE No.60839 PE No.58544 PE No.71457 PE No.77693
75322 Ply:1 SEQN:17447/T27/SPEC
Sherman Res. Qty: 1 FROM: DRW:
T04 Wgt:133.0 lbs ... / ... 06/06/2018
22
6'4"12 11'6" 14'6" 19'0"4 23'10" g4'111"
2'2"
6'4"12 5'1"4 �- 3' I 4'6"4 I 4.9'12 11' I
=4X4("")
3 12 D=4X8 E
v I
T =3X4C F,-----3X4T
5X5("")G 4X4("")in 50
B ! I=_4X5("") T
1 4X4(")
-
:Pro•ia
.n A _ Es - ` J 1 _0187"
P. 0 N M L CI K n
1113X4 E3X4 =5X7("") =3X4 =3X4
• -- 27' 1
1-2 I 6'3" I 5'3" I 2'10"4 I 4'11"8 I 7'8"4 I 2,
6'3- 11'6" 14'4"4 19'3"12 27'
1
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W
TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.295 M 999 320 p 999 /580 /- /- /- /3.5
BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.656 M 673 320 I 1075 /627 /- /- /- /3.5
BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.068 K - - Wind reactions based on MW FRS
Des Ld: 32.00 EXP:D HORZ(TL):0.110 K - - P Min Brg Width Req= 1.5
NCBCLL:10.00 Mean Height:20.11 ft Code/Misc Criteria Creep Factor:2.0 I Min Brg Width Req= 1.5
Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.667 Bearings P&I are a rigid surface.
Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.989
Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI:0.459 Maximum Top Chord Forces Per Ply(lbs)
C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber. Chords Tens.Comp. Chords Tens. Comp.
GCpi:0.18 Plate Type(s): A-B 28 -21 F-G 1612 -2952
Wind Duration:1.60 WAVE VIEW Ver:18.01.00.0323.07 B-C 1453-2694 G-H 1640 -3194
Lumber Loading ' C-D 1146-2074 H-I 1397 -2749
Value Set:13B(Effective 6/1/2013) Bottom chord checked for 10.00 psf non-concurrent E-E 1 -2080 I-J 28 21
Top chord 2x4 SP#2 live load. E-F 11149 49-2080
Bot chord 2x4 SP#2:62 2x4 SP#1:
Webs 2x4 SP#3 Wind Maximum Bot Chord Forces Per Ply(lbs)
Lumber value set"13B"uses design values Wind loads and reactions based on MWFRS. Chords Tens.Comp. Chords Tens. Comp.
approved 1/30/2013 by ALSC B-O 2580-1381 M-L 2810 -1538
Additional Notes O-N 2577 -1385 L-K 3820 -2031
Special Loads The overall height of this truss excluding overhang is N-M 1977 -1085 K-I 2640 -1333
-----(Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) 3-2-10.
TC:From 54 plf at -2.00 to 54 plf at 29.00 Top Chord overhang(s)may be field trimmed. Maximum Web Forces Per Ply(lbs)
BC:From 4 plf at -2.00 to 4 plf at 0.00 Webs Tens.Comp. Webs Tens. Comp.
BC:From 10 plf at 0.00 to 10 plf at 27.00
BC:From 4 plf at 27.00 to 4 plf at 29.00 O-C 154 0 M-F 480 -882
TC: 61 lb Conc.Load at 24.88 C-N 315 -631 F-L 254 -53
BC: 29 lb Conc.Load at 24.88 D-N 255 85 L-G 489 -986
Plating Notes D-M 35 -15 G-K 605 -991
M-E 316 -132 K-H 860 -474
("")6 plate(s)require special positioning.Refer to
scaled plate plot details for special positioning
requirements.
Plate positions consider a 0.50 inch truss perimeter
edge distance.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 -2.00 29.00
BC 49 0.15 26.85
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
NOTES:
f 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
(1.1.11) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer J"/\
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
Tr u eHo u s e PE No.Michael
08391owski PE No.58544son
o588544son PE No.Murray7457PE No.77769311
75322 Ply:1 SEQN:17423/T11/COMN -
Sherman Res. Qty: 1 FROM: DRW:
T05 Wgt:123.2 lbs , ... / ... 06/06/2018
7'1'12 I 13' I 176"12 I, 221'8 1231'8 27' I
7'1"12 5'10"4 4'6"12 4'6'12 1'I 3'10"8
3 12 D=4X4
v
N 03X4C E=4X5
114X5 ( ) To
F 4G
o
1 �� u7,`i� _ TT v
4X4(..)8 ±'� H=4X5(..) II
a_z A is __ I 1 I 0,67"
L K J 1
113X4 E5X7(") =4X8
1 27' 1
2 7' 6' 9'3"4 4'8'12
I 7' I 13' I 22'3"4 I 27' 2
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Def1ICSI Criteria ♦Maximum Reactions(lbs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W
TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.288 E 999 320 M 992 /459 /377 1- /72 /3.5
BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.640 E 690 320 H 992 /471 /382 /- /- /3.5
BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.066 J - - Wind reactions based on MWFRS
Des Ld: 32.00 EXP:D HORZ(TL):0.106 J - - M Min Brg Width Req= 1.5
NCBCLL:10.00 Mean Height:20.30 ft Code I Misc Criteria Creep Factor:2.0 H Min Brg Width Req= 1.5
Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.601 Bearings M&H are a rigid surface.
Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.980
Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI:0.591 Maximum Top Chord Forces Per Ply(lbs)
CBC Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp.
GCpi:0.18 Plate Type(s): A-B 28 0 E-F 1892 -3415
Wind Duration:1.60 WAVE VIEW Ver:18.01.00.0323.07 B-C 1426-2623 F-G 1713 -3152
Lumber Additional Notes C-D 1096-1893 G-H 1497 -2743
D-E 1111 -1882 H-I 28 0
Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is
Top chord 2x4 SP#2 3-7-2.
Bot chord 2x4 SP#2 Top Chord overhang(s)may be field trimmed. Maximum Bot Chord Forces Per Ply(lbs)
Webs 2x4 SP#3 Chords Tens.Comp. Chords Tens. Comp.
Lumber value set"13B"uses design values B-L 2508-1274 K-J 2432 -1300
approved 1/30/2013 by ALSC L-K 2506-1277 J-H 2632 -1384
Plating Notes
(")5 plate(s)require special positioning.Refer to Maximum Web Forces Per Ply(lbs)
Webs Tens.Comp. Webs Tens. Comp.
scaled plate plot details for special positioning
requirements. L-C 154 0 E-J 945 -454
Plate positions consider a 0.50 inch truss perimeter C-K 419 -788 F-J 668 -981
edge distance. D-K 620 -290 J-G 825 -503
K-E 483 -716
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 -2.00 29.00
BC 70 0.15 26.85
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent
live load.
Truss designed for unbalanced load using 0.00/1.00
windward/leeward factors.
Wind
Wind loads based on MWFRS with additional C&C
member design.
NOTES:
Nr- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
(TH) 2.Apex Technology is a fictitious name owned by Jan Apex Technology Inc.,Florida Corporation. Florida Engineer iii*/\
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
Tru eHo use Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell
PE No.60839 PE No.58544 PE No.71457 PE No.77693
75322 Ply:1 SEAN:17421/T2/COMN
Sherman Res. Qty: 1 FROM: DRW:
T06 Wgt:128.8 lbs ... / ... 06/06/2018
6' 11' 15' 20'1"81'1" 2T
I 6' I- 5' I 4' I- 5'1"8 1, 5'10"8 -I
=4X8 a
l 3 12 4E )
E
4X5(..) =4X4(..) T
ft3X4C 4111 ,
F G
N G
7 ti "Wel
=4X4(..)6 — _ billsH-4X4(..) iz (0
1 1s A .. _ I 11 I *18T
L K J 1
=3X4 =5X7(") =3X4
1 27 1
11' 3'10"4 5'6"12 67"
I`2' I 11' I 14'10"4 I 20'5" I 2T I 2'—I
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DeflICSI Criteria A Maximum Reactions(lbs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl Litt Loc R /U /Rw /Rh /RL /W
TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.271 K 999 320 M 992 /467 /393 /- /64 /3.5
BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.601 K 735 320 H 992 /477 /395 /- /- /3.5
BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.067 J - - Wind reactions based on MWFRS
Des Ld: 32.00 EXP:D HORZ(TL):0.107 J - - M Min Brg Width Req= 1.5
NCBCLL:10.00 Mean Height:20.05 ft Code I Misc Criteria Creep Factor:2.0 H Min Brg Width Req= 1.5
Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.502 Bearings M&H are a rigid surface.
Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.966
Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI:0.508 Maximum Top Chord Forces Per Ply(lbs)
CBC Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp.
GCpi:0.18 Plate Type(s): A-B 28 0 E-F 1364 -2144
Wind Duration:1.60 WAVE VIEW Ver:18.01.00.0323.07 B-C 1622-2658 F-G 1736 -2778
Lumber Additional Notes C-D 1313-2123 G-H 1633 -2665
Value Set:13B(Effective 6/1/2013) The overall height of this truss excluding overhang is D-E 1359-2062 H-I 28 0
Top chord 2x4 SP#2 3-1-2.
Bot chord 2x4 SP#2 Top Chord overhang(s)may be field trimmed. Maximum Bot Chord Forces Per Ply(lbs)
Webs 2x4 SP#3 Chords Tens.Comp. Chords Tens. Comp.
Lumber value set"13B"uses design values B-L 2549-1466 K-J 2862 -1690
approved 1/30/2013 by ALSC L-K 2027-1110 J-H 2552 -1509
Plating Notes
eb )
(")6 plate(s)require special positioning.Refer to Webs Maximum Tens.Comp.es Per Wbs Ply(Ib Tens. Comp.
scaled plate plot details for special positioning
requirements. C-L 372 -569 K-F 552 -845
Plate positions consider a 0.50 inch truss perimeter D-L 324 -41 F-J 427 -475
edge distance. D-K 241 -196 J-G 552 -381
K-E 270 -107
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 -2.00 29.00
BC 66 0.15 26.85
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent
live load.
Truss designed for unbalanced load using 0.00/1.00
windward/leeward factors.
Wind
Wind loads based on MW FRS with additional C&C
member design.
NOTES:
It- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
(11'14) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200 fiV\
APEX
TrueHouse PE No.Michael
08391owski
Jeffrey
No.58544son
o588544son PE No.71457y PE No.77769311
75322 Ply:1 SEAN:17419/T12/COMN
Sherman Res. Qty: 1 FROM: DRW:
T07 Wgt:120.4 lbs ... / ... 06/06/2018
1,9'1"8
9' 17' 18,1"1 '1
gr^127'
9' I 8' I1'1"ti I 7'10"8
3 12 ='H05C10("") �4XD("")114X5("")
T T1 ,`E + 4X5(») T
N O N O
N
IN =4X4(")B `'=4X4(..) N 2..,1 = A iJ i 187"
L'' K J I
=5X7("") =_5X7('") =3X4
1 27' 1
2, I 9'1"12 I T8"8 I 1'11"121 8'2" f 2'
9'1"12 16'10"4 1810" 27'
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DeflICSI Criteria ♦Maximum Reactions(lbs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W
TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.257 J 999 320 L 992 /498 /406 /- /56 /3.5
BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.567 J 779 320 G 992 /483 /406 /- /- /3.5
BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.062 I - - Wind reactions based on MWFRS
Des Ld: 32.00 EXP:D HORZ(TL):0.100 I - - L Min Brg Width Req= 1.5
NCBCLL:10.00 Mean Height:19.80 ft Code/Misc Criteria Creep Factor:2.0 G Min Brg Width Req= 1.5
Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.869 Bearings L&G are a rigid surface.
Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.963
Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI:0.460 Maximum Top Chord Forces Per Ply(lbs)
C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp.
GCpi:0.18 Plate Type(s): A-B 28 0 E-F 1541 -2464
Wind Duration:1.60 WAVE,HS VIEW Ver:18.01.00.0323.07 B-C 1486 -2496 F-G 1540 -2554
Lumber Additional Notes C-D 1531 -2410 G-H 28 0
D-E 1529 -2435
Value Set:136(Effective 6/1/2013) The overall height of this truss excluding overhang is
Top chord 2x4 SP#2:T1 2x4 SP#1: 2-7-2.
Bot chord 2x4 SP#2 Top Chord overhang(s)may be field trimmed. Maximum Bot Chord Forces Per Ply(lbs)
Webs 2x4 SP#3 Chords Tens.Comp. Chords Tens. Comp.
Lumber value set"13B"uses design values B-K 2375-1328 J-I 2504 -1429
approved 1/30/2013 by ALSC K-J 2382-1325 I-G 2436 -1409
Plating Notes
("1 8 plate(s)require special positioning.Refer to Maximum Web Forces Per Ply(lbs)
Webs Tens.Comp. Webs Tens. Comp.
scaled plate plot details for special positioning
requirements. C-K 266 0 J-E 87 -243
Plate positions consider a 0.50 inch truss perimeter C-J 417 -373 E-I 171 -222
edge distance. J-D 290 -11 I-F 286 -110
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 -2.00 29.00
BC 71 0.15 26.85
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
Loading
Bottom chord checked for 10.00 psf non-concurrent
live load.
Truss designed for unbalanced load using 0.00/1.00
windward/leeward factors.
Wind
Wind loads based on MWFRS with additional C&C
member design.
NOTES:
N- 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
6111) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
Tru eHo use Michael G Kozlowski Jeffrey P Ameson Derek B Murray Adam K Russell
PE No.60839 PE No.58544 PE No.71457 PE No.77693
75322 Ply:1 SEAN:17488/T10/COMN
Sherman Res. Qty: 1 FROM: DRW:
T08 Wgt:149.8 lbs ... / ... 06/06/2018
1. 10' 21'6"9
6'8"4 + 8'6" 1'6"1 111'10"15 151"12 I 18'4"9 I 20''� 16'9 I 27'HI
6'8"4 1'9"12 1'10"151 3'2"13 3'2"13 17"7 5'5"7
12
3 i- Dm5X7("")116X8("") '<3X4 w4X4wH0510(") T
( . %3X4C �E F_3X4 G H I J 3X4 I
T
�' -/ -_ T4 4X5(".) "- N
EN �4X8(A1T)B `,,, - - K=4X5(••) N
1 A - .l' L 1 r'_18'7-
Q P O N M 1
m6X8 ' 3X4 mH1010(") m4X5 =4X8
1 27 1
I-2' I
8'4"4 I 1'11"4 I 3'2"13 I 3'2"13 I 3'4"9 I 6'10"4 I 2,
8'4"4 10'3"8 13'6"5 16'9"3 20'1"12 27'
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) DeRICSI Criteria ♦Maximum Reactions(lbs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl LJ# Loc R /U /Rw /Rh /RL /W
TCDL: 7.00 Speed: 130 mph P1:NA Ce:NA VERT(LL): 0.425 G 753 320 R 1385 /778 /- /- /- /3.5
BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.965 G 461 320 S 1787 /999 /- /- /- /3.5
BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.071 M - - Wind reactions based on MWFRS
Des Ld: 32.00 EXP:D HORZ(TL):0.116 M - - R Min Brg Width Req= 1.5
NCBCLL:0.00 Mean Height:19.74 ft Code/Misc Criteria Creep Factor:2.0 S Min Brg Width Req= 1.8
Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.534 Bearings R&S are a rigid surface.
Load Duration:1.25 BCDL:3.0 psi TPI Std: 2014 Max BC CSI: 0.999
Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:No Max Web CSI:0.656 Maximum Top Chord Forces Per Ply(lbs)
C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp.
GCpi:0.18 Plate Type(s): A-B 28 -19 G-H 3910 -7102
Wind Duration:1.60 WAVE,HS VIEW Ver:18.01.00.0323.07 B-C 2330 -4192 H-I 3062 -5596
Lumber Wind C-D 22),-4073 I-J 3193 -5834
Value Set:13B(Effective 6/1/2013) Wind loads and reactions based on MWFRS. E-E 3127-550 E-F 3027-55011 J-K 3220 -5-19
K-L 28 -19
Top chord 2x6 SP SS Dense:T1 2x4 SP SS: Additional Notes F-G 3573-6499
:T4 2x4 SP M-31:
Bot chord 2x6 SP SS Dense The overall height of this truss excluding overhang is Maximum Bot Chord Forces Per Plylbs
Webs 2x4 SP#3 2-5-10. ( )
Lumber value set"136"uses design values Chords Tens.Comp. Chords Tens. Comp.
approved 1/30/2013 by ALSC B-Q 4034-2235 0-N 6895 -3813
Special Loads Q-P 5400-2971 N-M 6449 -3556
P-0 6085-3362 M-K 5621 -3101
(Lumber Dur.Fac.=1.25/Plate Dur.Fac=1.25)
TC:From 54 pit at -2.00 to 54 plf at 29.00 Maximum Web Forces Per Ply(lbs)
BC:From 4 p11 at -2.00 to 4 pli at 0.00 Webs Tens.Comp. Webs Tens. Comp.
From 10 plf at 0.00 to 10 plf at 27.00
BC:From 4 plf at 27.00 to 4 plf at 29.00 C-Q 205 -99 O-G 342 -563
BC: 825 lb Conc.Load at 17.06 Q-D 1722 -926 G-N 550 -137
BC: 373 lb Conc.Load at 20.00 Q-E 1237 -2196 N-H 928 -503
Plating Notes E-P 573 -323 H-M 674 -1163
6 plate(s)require special positioning.Refer to P-F 476 -830 I-M 1151 -616
("") P O q P
scaled plate plot details for special positioning F-O 588 -299 M-J 183 19
requirements.
Plate positions consider a 0.50 inch truss perimeter
edge distance.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 -2.00 29.00
BC 51 0.15 26.85
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
NOTES:
r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
(11'1.1) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer /fit\
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
- APEX
Tru eHo use Kozlowski Derek B Murray Adam K Russell
PE Michael No.60839G Jeffrey P Arneson
PE No.58544 PE No.71457 PE No.77693
75322 Ply:1 SEQN:17451/T14/COMN •
Sherman Res. Qty: 1 FROM: DRW:
T09 Wgt:61.6 lbs ... / ... 06/06/2018
8'6" 17'
I I -I
8'6" 8'6"
12
3 ✓ MI C. 5X5(")
ill MI
0
N =3X4(**)B D=3X4(..) iN
__ .�:A i NO 1_418'7'
F ' E
=5X5(")
1 17' 1
8,6„ 8,6„
2 I I I
8'6" 17'
Loading Criteria(psi) Wind Criteria Snow Criteria(Pg,Pf in PSF) DefUCSI Criteria ♦Maximum Reactions(Ibs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc Udefl U# Loc R /U /Rw /Rh /RL /W
TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.070 E 999 240 F 673 /333 /271 /- /59 /3.5
BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.175 E 999 200 D 547 /231 /217 /- /- /-
BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.019 E - - Wind reactions based on MWFRS
Des Ld: 32.00 EXP:D HORZ(TL):0.032 E - - F Min Brg Width Req= 1.5
NCBCLL:10.00 Mean Height:19.74 ft Code/Mist Criteria Creep Factor:2.0 D Min Brg Width Req= -
Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.824 Bearing F is a rigid surface.
Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.989
Spacing:24.0" MWFRS Parallel Dist:h/2 to h Rep Factors Used:Yes Max Web CSI:0.105 Maximum Top Chord Forces Per Ply(lbs)
C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber: Chords Tens.Comp. Chords Tens. Comp.
GCpi:0.18 Plate Type(s): A-B 28 0 C-D 762 -1316
Wind Duration:1.60 WAVE VIEW Ver:18.01.00.0323.07 B-C 754 -1317
Lumber Wind
Value Set:13B(Effective 6/1/2013) Wind loads based on MWFRS with additional C&C Maximum Bot Chord Forces Per Ply(Ibs)
Top chord 2x4 SP#2 member design. Chords Tens.Comp. Chords Tens. Comp.
Bot chord 2x4 SP#2 B-E 1237 -669 E-D 1237 -669
Webs 2x4 SP#3 Additional Notes
Lumber value set"13B"uses design values The overall height of this truss excluding overhang is Maximum Web Forces Per PlyIbs
approved 1/30/2013 by ALSC 2-5-10. Webs Tens.Comp. (lbs)
Top Chord overhang(s)may be field trimmed.
Plating Notes C-E 274 0
(")4 plate(s)require special positioning.Refer to
scaled plate plot details for special positioning
requirements.
Plate positions consider a 0.50 inch truss perimeter
edge distance.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 -2.00 17.00
BC 97 0.15 16.88
Apply purlins to any chords above or below fillers
at 24"OC unless shown otherwise above.
Hangers I lies
(J)Hanger Support Required,by others
Loading
Bottom chord checked for 10.00 psf non-concurrent
live load.
Truss designed for unbalanced load using 0.00/1.00
windward/leeward factors.
NOTES:
r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
(1:14) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer fiV\
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
Tru eHo u se Michael G Kozlowski Jeffrey P Arneson Derek B Murray Adam K Russell
PE No.60839 PE No.58544 PE No.71457 PE No.77693
•
" 75322 Ply:1 SEAN:17467/T7/HIPS
Sherman Res. Qty: 1 FROM: DRW:
T10 Wgt:64.4 lbs / ... 06/06/2018
7' 10' 17'
I7' I 3' I 7' I
12 -4X4(") =4X4(")
.- D
C
3
T T
°N O
N T =3X4(.")B E=3X4(„) n
‘1
I � A1/4 .__,�- 1. 118'7"
t, 'F
5X7(")
r 8'10"4 1- 8'1"12 j
2, 810 4 8'1"12
8'10"4 I 17'
Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Deft/CSI Criteria A Maximum Reactions(lbs)
TCLL: 20.00 Wind Std: ASCE 7-10 Pg:NA Ct:NA CAT:NA PP Deflection in loc L/defl L/# Loc R /U /Rw /Rh /RL /W
TCDL: 7.00 Speed: 130 mph Pf:NA Ce:NA VERT(LL): 0.076 F 999 240 B 517 /300 /- /- /- /3,0
BCLL: 0.00 Enclosure:Closed Lu:NA Cs:NA VERT(TL): 0.181 F 830 180 F 1698 /882 /- /- /- /3.5
BCDL: 5.00 Risk Category:II Snow Duration:NA HORZ(LL): 0.023 F - - E 262 /137 /- /- /- /-
Des Ld: 32.00 EXP:D HORZ(TL):0.038 F - - Wind reactions based on MWFRS
NCBCLL:10.00 Mean Height:19.55 ft Code/Misc Criteria Creep Factor:2.0 B Min Brg Width Req= 1.5
Soffit: 2.00 TCDL:4.2 psf Bldg Code: FBC 2017 RES Max TC CSI: 0.869 F Min Brg Width Req= 2.0
Load Duration:1.25 BCDL:3.0 psf TPI Std: 2014 Max BC CSI: 0.948 E Min Brg Width Req= -
Spacing:24.0" MWFRS Parallel Dist:0 to h/2 Rep Factors Used:Yes Max Web CSI:0.181 Bearings B 8 F are a rigid surface.
C&C Dist a:3.00 ft FT/RT:30(0)/10(0) Mfg Specified Camber. Maximum Top Chord Forces Per Ply(lbs)
GCpi:0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp.
Wind Duration:1.60 WAVE VIEW Ver:18.01.00.0323.07
Lumber Purlins A-B 28 -20 C-D 181 -175
B-C 304 -532 D-E 119 -290
Value Set:13B(Effective 6/1/2013) In lieu of structural panels or rigid ceiling use purlins
Top chord 2x4 SP#2 to laterally brace chords as follows:
Bot chord 2x4 SP#1 Chord Spacing(in oc) Start(ft) End(ft) Maximum Bot Chord Forces Per Ply(lbs)
Webs 2x4 SP#3 TC 24 -2.00 17.00 Chords Tens.Comp. Chords Tens. Comp.
BC 118 0.12 16.88
Lumber value set"13B"uses design values Apply purlins to any chords above or below fillers B-F 480 -263 F-E 240 -83
approved 1/30/2013 by ALSC at 24"OC unless shown otherwise above.
Special Loads Maximum Web Forces Per Ply(lbs)
pe Hangers/Ties Webs Tens.Comp. Webs Tens. Comp.
-----(Lumber Dur.Fac.=1.25/Plate Dur.Fac.=1.25) Recommended hanger connections are based on
TC:From 54 plf at -2.00 to 54 plf at 7.00 manufacturer tested capacities and calculations. C-F 610 -805 F-D 479 -622
TC:From 27 plf at 7.00 to 27 plf at 10.00 Conditions may exist that require different
TC:From 54 plf at 10.00 to 54 plf at 17.00 connections than indicated.Refer to manufacturer
BC:From 4 plf at -2.00 to 4 plf at 0.00 publication for additional information.
BC:From 10 plf at 0.00 to 10 plf at 7.01 Bearingat location x=16'9" uses the following
From 5 plf at 7.01 to 5 plf at 9.99 fllg
BC:From 10 plf at 9.99 to 10 plf at 17.00 support conditions:16'9"
TC: 373 lb Conc.Load at 7.01 Bearing E (16'9",18'7")LUS26
TC: 163 lb Conc.Load at 8.50 Supporting Member:(1)2x6 SP SS Dense
TC: 301 lb Conc.Load at 9.99 (4)0.148"x3"nails into supporting
BC: 339 lb Conc.Load at 7.01 member,
BC: 92 lb Conc.Load at 8.50 (3)0.148"x3"nails into supported
BC: 85 lb Conc.Load at 9.99 member.
Plating Notes Wind
(")5 plate(s)require special positioning.Refer to Wind loads and reactions based on MWFRS.
scaled plate plot details for special positioning Additional Notes
requirements.
Plate positions consider a 0.50 inch truss perimeter The overall height of this truss excluding overhang is
edge distance. 2-1-2.
Top Chord overhang(s)may be field trimmed.
Loading
Bottom chord checked for 10.00 psf non-concurrent
live load.
NOTES:
r 1.This drawing is not sufficient alone for installation. Additional instructions accompanying this truss drawing,include BCSI 1-03,
should be used in conjunction with the architectural plans during installation.
(11'14) 2.Apex Technology is a fictitious name owned by Jax Apex Technology Inc.,Florida Corporation. Florida Engineer /gt/\
Business No.7547-4745 Sutton Park Court,Suite 402,Jacksonville,FL 32224-904.821.5200
APEX
Tru eHo use PE No.l 60839 Kozlowski PE No.SA e4son PE No.Murray7457PE No.77769311