1678 ATLANTIC BEACH DR - ELECTRIC POOL )
firi
iCITY OF ATLANTIC BEACH
rs1
5 p 800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
�0;11>%• INSPECTION PHONE LINE 247-5814
ELECTRICAL RESIDENTIAL -
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
PERMIT INFORMATION:
PERMIT NO: ERES18-0314
Description: ELECTRIC -SWIMMING POOL
Estimated Value: 0
Issue Date: 9/24/2018
Expiration Date: 3/23/2019
PROPERTY ADDRESS:
Address: 1678 ATLANTIC BEACH DR
RE Number: 169505 1720
PROPERTY OWNER:
Name: ATLANTIC BEACH PARTNERS LLC
Address: 414 OLD HARTS RD STE 502
FLEMING ISLAND, FL 32003
GENERAL CONTRACTOR INFORMATION:
Name:
Address:
,
Phone:
Name: DAVID PRUETTES ELECTRICAL SVC.
Address: 331 -8 P PARKRIDGE AVE QA DAVID THOMAS PRUETTE
ORANGE PARK, FL 32065
Phone:
PERMIT INFORMATION:
Please see attached conditions of approval.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB
SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY
BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions
applicable to this property that may be found in the public records of this county, and there may
be additional permits required from other governmental entities such as water management
districts, state agencies, or federal agencies.
* A notice of Commencement is only required for work exceeding an estimated value of
$2,500. For HVAC work, a Notice of Commencement is only required when HVAC work
exceeds and estimated value of$7,500.
rd ••4 ELECTRICAL PERMIT APPLICATION
it bathic
CITY OF ATLANTIC BEACH
800 Seminole Rd,Atlantic Beach, FL 32233 - -
Ph(904) 247-5826 Fax (904) 247-5845 CRESG _ 03( q-
JOB ADDRESS: (til 8 At-VIA-1i C, 3ek 1 PERMIT# 18--ooag
JEA INFORMATION REQUIRED ON ALL PERMITS AMPS VOLTS PHASE
VALUE OF WORK$ bd.W
NEW SERVICE D Overhead [1 Underground 1 U Underground up Pole
❑Residential(Main)Service
00-100 amps 0 101-150amps Li 151-200amps 0 amps #of Meters
0 Commercial(Main) Service
❑0-100 amps 0 101-150amps ❑151-200amps 0 amps ❑CT Service amps
Conductor Type Size
❑Multi-Family(Main)Service
00-100 amps ❑101-150amps ❑151-200amps n amps #of Unit Meters
0 Temporary Pole ❑ amps
SERVICE UPGRADE ❑ amps ❑ CT Service amps
NEW FEEDER(ADDITIONS,ACCESSORY STRUCTURES,ETC.)
0100 amps ❑150amps 0200amps l; amps OCT Service amps
ADDITIONS,REMODELS,REPAIRS,BUILD-OUTS,ACCESSORY STRUCTURES,ETC.
Outlets/Switches: 0-3 Oamps 31-100amps 101-200amps
Appliances: 0-30amps 31-100amps 101-200amps
A/C Circuits: 0-60amps 61-100amps
Heat Circuits: # circuits @ kw
Number of Lighting Outlets, Including Fixtures:
OTH`Jl1LECTRICAL PROJECTS
_Swimming Pool is Sign ❑Smoke Detectors Qty El Transformers KVA ❑Motors hp
FIRE ALARM SYSTEM (Requires 3 sets of plans)
Qty volts/amps VALUE OF WORK$
REPAIRS,MISCELLANEOUS
UReplace Burnt/Damaged Meter Can [_ISafety Inspection ❑Panel Change LI OH to UG
Other:
permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have
-cad this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether
;pecified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of
;onstruction. aa
?roperty Owners Name—re) 144a.- woodcak. Phone Number
Electrical CompanyJ)av 1 PYUe#? dnced S('C. Office Phone &7 7;a5- Fax 37d-7299
�o. Address: 331 - d PanowiseCity Cila
; Stated Zip i�+ 5
.icense Holder(Print): IA/# pL_ .iiiii- „.00111. /S ;, :;%cation/Registration# z5Ca93
Votarized Signature of License Holder '
,.o`+Z,':. CHO ROBERTS efore me this 20 day of 20 '
: Notary Public-State of Florida• �_
'a"!�u Commission#GG 211925
`7)''orn p My Comm.Expires Aug 21,2022 Signature of Notary Public
Bonded through National Notary Assn.
f:1i` Cash Register Receipt Receipt Number
-vverz City of Atlantic Beach R6541
j;)?
DESCRIPTION I ACCOUNT I QTY I PAID
PermitTRAK $99.00
ERES18-0314 Address: 1678 ATLANTIC BEACH DR APN: 169505 1720 $99.00
ELECTRICAL $95.00
ELECTRICAL BASE FEE 455-0000-322-1000 0 $55.00
ELEC SWIMMING POOLS 455-0000-322-1000 0 $40.00
STATE SURCHARGES $4.00
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL FEES PAID BY RECEIPT: R6541 $99.00
Date Paid: Monday, September 24, 2018
Paid By: DAVID PRUETTES ELECTRICAL SVC.
Cashier: LE
Pay Method: CHECK 12086
Printed: Monday,September 24,2018 4:33 PM 1 of 1
nwar
MAP SHOWING AS -BUILT SURVEY OF
LOT 85 AS SHOWN ON MAP OF
ATLANTIC BEACH COUNTRY CLUB UNIT 2
AS RECORDED IN PLAT BOOK 67 PAGES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLA.
CERTIFIED TO. NICHOLAS D. WOODCOCK / MICHELE G. WOODCOCK
/ WELLS FARGO BANK, N.A. / WESTMINSTER TITLE AGNECY, INC.
/ CHICAGO TITLE INSURANCE COMPANY
FINAL; W.O. #169442; 12-21-18 (FIELD)
FOUNDATION, F.F.E.; W.O.# '162532; 3-29-18 (FIELD)
LOT & HOUSE S-O(GOOD SET F.F.E.) W.O.#161647: 2-24-18 (FIELD)
THIS SURVEY WAS PERFORMED WITHOUT THE BENEFIT OF A TITLE COMMITMENT.
THERE MAY BE ADDITIONAL EASEMENTS AND/OR RESTRICTIONS THAT ARE NOT SHOWN
ON THIS SURVEY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY.
(00.0) - DENOTES PRE -CONSTRUCTION ELEVATION
00.0 - DENOTES POST -CONSTRUCTION ELEVATIONS
- DENOTES DIRECTION OF FLOW
NOTE:
SIDE/FRONT BUILDING TIES ARE TO THE FOUNDATION.
UNE L1
S14'27'25"E 55.00'
WI
c.
BENCHMARK:
FND NAIL & DISK PEGGED
MANHOLE AT C.L.I. OF
COASTAL OAKS LANE AND
ATLANTIC BEACH DRIVE
ELEVATION: (7.92)
ELEVATIONS SHOWN HEREON
REFER TO NAVD OF 1988
DENOTES FOUND 1/2"
0 IRON PIPE LB 3848
UNLESS OTHERWISE NOTED
WM - DENOTES WATER METER
RC - DENOTES RECLAIMED WATER METER
THE LOT SHOWN HEREON IS IN THE SPECIAL FLOOD HAZARD ZONE "X" AS SHOWN
ON FLOOD INSURANCE RATE MAP 0408 J FOR THE CITY OF JACKSONVILLE, FLORIDA, DATED 11-02-18
ALL. AMERICAN SURVEYORS OF FLORIDA, INC.
LANLI SURVEYORS — 3751 SAN JOSE PLACE, SUITE 15 — JACKSONVILLE, FLORIDA, 32257 — 904/279-0088 — LICENSED LAND BUSINESS NO. 3857
COV.
- COVERED
RRE. - FINISH FLOOR ELEVATION
FND.
- FOUND
A/C - AIR CONDITIONER
ESM'T - EASEMENT
I.D. = IDENTIFICATION
GONG
- CONCRETE
P.R.M. - PERMANENT REFERENCE
MON.
- MONUMENT
MONUMENT
I.P.
- IRON PIPE
P.T. - POINT OF TANGENCY
I.R.
- IRON ROD
P.C.F. - PERMANENT CONTROL POINT
A
= DELTA ANGLE
P.C. - POINT OF CURVE
CH
- CHORD
P.R.C. - POINT OF REVERSE CURVE
A
- ARC LENGTH
P.C.C. - POINT OF COMPOUND CURVE
B.R.L - BUILDING RESTRICTION
(CAL.C.)
- CALCULATED
F.P.&L= FLORIDA POWER & LIGHT
({D
-DEED
(TYP:I - TYPICAL
(P3
- PLAT
NGVD - NATIONAL GEODETIC VERTICAL
(R
- RADIAL LINE
DATUM
rt
= CENTER LINE
NAVD - AMERICAN VERTICAL
R/W
RIGHT-OF-WAY
DNORTH ATUM
-x-
-
-FENCE
P I - POINT OF INTERSECTION
EOW - EDGE OF WATER
(w)
- WETNESS
TOB - TOP OF BANK
F.B. PRINT D. C. N/A DR. BY TTH
THIS IS TO CERTIFY THAT THE ABOVE LANDS WERE SURVEYED UNDER MY RESPONSIBLE
SUPERVISION AND DIRECTION, THAT THERE ARE NO ENCROACHMENTS EXCEPT AS SHOWN
AND THAT THE SURVEY SHOWN HEREON MEETS THE MINIMUM, TECHNICAL STANDARDS
SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL SURVEYORS AND MAPPERS
PURSUANT TO CHAPTER 472.027 / CHAPTER 61G1-7-6,-FI_OR!DA STATUTES.
SURVEY NOT VALID UNLESS EMBOSSED BY SEAL
JAMES D. HARRISON, JR., No. 2647
MICHAEL A. GARRETT, No. 6643 %
SCALE 1 "=20'
DATE 12-06-17
FLOR115A.-REGISTERED S RVEYOR A MAPPER
DIR. P;\2017\83002 ORDER N0. 169442—FNL
FILE 83002