Loading...
1746 MARITIME OAK DR - MISC DRAWINGSMAP SHOWING PL 0 T PLAN OF L 0 T 111 AS SHOWN ON MAP OF ATLANTIC BEACH COUNTRY CLUB UNIT 2 AS RECORDED IN PLAT BOOK 67 PAGES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUAL COUNTY, FLA. CERTIFIED TO. TOLL BROTHERS, INC. --^- DENOTES DIRECTION OF FLOW TYPE "A" DRAINAGE ELEVATIONS SHOWN THUS (11.80) WERE TAKEN FROM ENGINEERING PLANS BY TAYLOR & WHITE, INC., DATED 04-15-14 ELEVATIONS SHOWN HEREON REFER TO NAVD OF 1988 VE`�pMEN� CO RpvE App DIMENSIONS SHOWN HEREON ARE PER FOUNDATION PLAN LOT 111 MODEL "CAPTIVA" LOT SIZE 6,600± SQ. FT. DRIVEWAY TO R/W 315± SQ. FT. APPROXIMATE SIDEWALK 220± SQ. FT. ENTRY WALK 38± SQ. FT. RIGHT-OF-WAY LENGTH TOTAL IMPERVIOUS COVERAGE TOTAL EASEMENT AREA 55.00 FT. 4,003± SQ. FT. 61% O± SQ. FT. NOTE: BUILDER TO MAINTAIN 3.0' BETWEEN A/C PAD AND PROPERTY LINE. BUILDERS ENDORSEMENT SIGNED: NAME: DATE: O �A L. J JaQ �2 n . -ii"' O \ �>O O�G4S A €c F�Fo RAS°q Grp ti s� �P Oaoh��a 1 NOTE -ALL BUILDING TIES ARE MEASURED TO THE FOUNDATION WALLS. O F.F.E. r FINISH FLOOR ELEVATION O _ .5 G �5��, GPeO Ol N01Dv o� , N NC *` AIR CONDITIONER oQ°opo t. NOTE: BUILDER TO MAINTAIN 3.0' BETWEEN A/C PAD AND PROPERTY LINE. BUILDERS ENDORSEMENT SIGNED: NAME: DATE: O �A L. J JaQ �2 n . -ii"' O \ �>O O�G4S A €c F�Fo RAS°q Grp ti s� �P Oaoh��a 1 NOTE -ALL BUILDING TIES ARE MEASURED TO THE FOUNDATION WALLS. O F.F.E. r FINISH FLOOR ELEVATION _ .5 . - FOUND NC *` AIR CONDITIONER O -_ IESM? - EASEMENT I.D. "' IDENTIFICATION ALL PAVERS ALL MEASUREMENTS ESTIMATED FRONT 456± SQ. FT. BACK 224± SQ. FT. TREE SCHEDULE LOT SQ. FT. MINUS EASEMENTS/WETLANDS 6,600 ACRES= 6,600/43,560 0.15 ACRESx40=REQUIRED TREE INCHES 6.0 THE REQUIRED NUMBER OF TREE INCHES WILL BE MET USING 2" DIAMETER TREES. 70% OF REQUIRED PLANTED TREES SHALL BE CANOPY TYPE, WITH NO MORE THAN 50% OF THE SAME SPECIES. THE LOT SHOWN HEREON IS IN THE SPECIAL FLOOD HAZARD ZONE "X" AS SHOWN ON FLOOD INSURANCE RATE MAP 0405 H FOR THE CITY OF JACKSONVILLE, FLORIDA, DATED 06-03-13 ALL AMERICAN SURVEYORS OF FLORIDA, INC. LAND SURVEYORS — 3751 SAN JOSE PLACE, SURE 15 — JACKSONVILLE, FLORIDA, 32257 — 904/279-0088 — LICENSED LAND BUSINESS NO. 3857 Legend Coo-COVERED F.F.E. r FINISH FLOOR ELEVATION _ .5 . - FOUND NC *` AIR CONDITIONER -_ IESM? - EASEMENT I.D. "' IDENTIFICATION SKETCH FOR PLOT PLAN ONLY — DOES NOT REPRESENT OR PURPORT TO SHOW — 4 -CONCRETE P.R.M. r PERMANENT REFERENCE ONUMENT BOUNDARY LINES NOR IS IT BASED ON A FIELD RUN SURVEY- MONUMENT IRON PIPE P•T• r POINT OF TANGENCY JONC - IRON ROO P.C.P.. +. PERMANENT CONTROL POINT ALL - DELTA ANGLE CHORD P.C. • POINT OF CURVE P.R.C. r POINT OF REVERSE CURVE AMERICAN A GTH P.C.C. r POINT OF COMPOUND CURVE S.R.L.r BUILDING RESTRICTION SURVEY NOT VALID UNLESS EMBOSSED BY SEAL SURVEYORS R RADIUS C LC uTED F.P.& FLORIDOF POWER & LIGHT JAMES D. HARRISON, JR., No. 2647 FLORIDA, r TYPICAL MICHAEL A GARRETi, No. 6643 INC. P - PUT R - RADLLL UNE - CENTER UNE NGVD r AGEODETIC VERTICAL D DATUM NAVD r NORTH AMERICAN VERTICAL SCALE RIGHT-OF-WAY -FENCE DATUM P.I. r POINT OF INTERSECTION /T — 9 (W) - WITNESS EOW r EDGE OF WATER r TOP OF BANK f/�/ DATE 06-05-18 FLOR A GISTERED S VEYOR I MAPPER _-8 croe B• X DR. BY BRB DIR. P:\2018\84288-164361—plotplan ORDER NO. 164361 FILE 84288 MAP SHOWING PLOT PLAN OF LOT 111 AS SHOWN ON MAP OF ATLANTIC BEACH COUNTRY CLUB UNIT 2 AS RECORDED IN PLAT BOOK 67 PAGES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUAL COUNTY, FLA. CERTIFIED TO: TOLL BROTHERS, INC. --� DENOTES DIRECTION OF FLOW TYPE "A" DRAINAGE ELEVATIONS SHOWN THUS (11.80) WERE TAKEN FROM ENGINEERING PLANS BY TAYLOR & WHITE, INC., DATED 04-15-14 Q9' ELEVATIONS SHOWN HEREON REFER TO NAVD OF 1988 J� .O 2 ° �� O .In psi 40 / o -0 cFP �Q ` env 10 i�p°o 'y ��TF >O��a°� c pO'p GJ ��p GPQ O SO �`�`� Yotio Fo �P O 01 p s 0 .o � �' F • OQ P ,� --1 Cp�� 3ia 9�'� cF0 Y'O. 5 '\ \ .O +R. �O \ 9° . Gp `SS \Q s1 NOTE -ALL BUILDING TIES ARE MEASURED S'F 00+ v TO THE FOUNDATION WALLS. N' O APPROVED (e a P, �--/p DIMENSIONS SHOWN HEREON ARE PER FOUNDATION PLAN LOT 111 LOT SIZE MODEL "CAPTIVA" 6,600± SQ. FT. DRIVEWAY TO R/W 315± SQ. FT. APPROXIMATE SIDEWALK 220± SQ. FT. ENTRY WALK 38± SQ. FT. RIGHT-OF-WAY LENGTH 55.00 FT. TOTAL IMPERVIOUS COVERAGE 4,003± SQ. FT. 61% TOTAL EASEMENT AREA O± SQ. FT. NOTE: BUILDER TO MAINTAIN 3.0' BETWEEN A/C PAD AND PROPERTY LINE. BUILDERS ENDORSEMENT SIGNED: NAME: DATE: ALL PAVERS ALL MEASUREMENTS ESTIMATED FRONT 456± SQ. FT. BACK 224± SQ. FT. TREE SCHEDULE LOT SQ. FT. MINUS EASEMENTS/WETLANDS 6,600 ACRES=6,600/43,560 0.15 ACRESx40=REQUIRED TREE INCHES 6.0 THE REQUIRED NUMBER OF TREE INCHES WILL BE MET USING 2" DIAMETER TREES. 70% OF REQUIRED PLANTED TREES SHALL BE CANOPY TYPE, WITH NO MORE THAN 50% OF THE SAME SPECIES. THE LOT SHOWN HEREON IS IN THE SPECIAL FLOOD HAZARD ZONE "X" AS SHOWN ON FLOOD INSURANCE RATE MAP 0405 H FOR THE CITY OF JACKSONVILLE, FLORIDA, DATED 06-03-13 ALL AMERICAN SURVEYORS OF FLORIDA, INC. LAND SURVEYORS - 3751 SAN JOSE PLACE, SUITE 15 - JACKSOAMLL& FLORIDA, 32257 - 904/279-OOBB - LICENSED LAND BUSINESS NO. 3857 Legend _ 5 COV. -COVERED F.F.E. + FINISH FLOOR ELEVATION FNO. - FOUND I.D. + IVDEN�FlGTON R SKETCH FOR PLOT PLAN ONLY - DOES NOT REPRESENT OR PURPORT TO SHOW cONC - CONCRETE P.R.M. + PERMANENT REFERENCE BOUNDARY LINES NOR IS IT BASED ON A FIELD RUN SURVEY _-4 MON. - MONUMENT I.P. - IRON PIPE MONUMENT GENCY ALL I.R. - IRON ROD P C.P. +� PERMANENT CONTROL POINT . C DELTA ANGLE P.C. + POINT OF CURVE AMERICAN CH -CHORD A - ARC LENGTH P.R.C. + POINT OF REVERSE CURVE P.C.C. + POINT OF COMPOUND CURVE SURVEY NOT VALID UNLESS EMBOSSED BY SEAL SURVEYORS R - RADIUS B.R.L +. BUILDING RESTRICTION OF FLORIDA, (� .) �o uTED F(TMP.) rn� POWER Mk ucHr JAMES 0..HARRISON,GREIT JR., No. 2647 - + MICHAEL A GARRETT, No. 6843 P - PUT R - RADIAL LINE rt - CENTER UNE NGVD NATIONAL GEODETIC VERTICAL DATUM NAVO + NORTH AMERICAN VERTICAL SCALE 1 "s20' R/W - RIGHT-OF-WAY DATUM ^ J /r--�Oe 7 g FE14CE P.I. . POINT OF INTERSECTION I - (W) - WITNESS EOW . EDGE OF WATER roe . TOP OF BANK DATE 06-05-18 FLO A GISTERED S6RVEYOR AW MAPPER —8 F.8. X DR. BY BRB DIR, P:\2018\84288-164361-plotplan ORDER NO. 164361 FILE 84288 MAP SHOWING PLOT PLAN OF i L 0 T 111 AS SHOWN ON MAP OF ATLANTIC BEACH COUNTRY CLUB UNIT 2 AS RECORDED /N PLAT BOOK 67 PACES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUAL COUNTY, FLA. CERTIFIED TO: TOLL BROTHERS, INC. --� DENOTES DIRECTION OF FLOW TYPE "A" DRAINAGE ELEVATIONS SHOWN THUS (11.80) WERE TAKEN FROM ENGINEERING PLANS BY TAYLOR & WHITE, INC., DATED 04-15-14 QA ELEVATIONS SHOWN HEREON \ REFER TO NAVD OF 1988 O O � 1 � 1 �ry�• y�0 r,�� �Pl o � DIMENSIONS SHOWN HEREON ARE PER FOUNDATION PLAN LOT 11 MODEL "CAPTIVA" LOT ,SIZE 6,600± SQ. FT. DRIVEWAY TO R/W 315± SQ. FT. APPR XIMATE SIDEWALK 220± SQ. FT. ENTRY WALK 38± SQ. FT. RIGHT-OF-WAY LENGTH 55.00 FT. TOTA _ IMPERVIOUS COVERAGE 4,003± SQ. FT. 61% _ EASEMENT AREA O± SQ. FT. TOTA NOTE: BUILDER TO MAINTAIN 3.0' BETWEEN A/C PAD AND PROPERTY LINE. BUILDERS ENDORSEMENT SIGNED: NAME: DATE: OFFICE COPY 'p yl c NOTE -ALL BUILDING TIES ARE MEASURED TO THE FOUNDATION WALLS. 09 0 �O _ 5 Qty J��O��G "SJP FND. - FOUND ASC r NR CONDITIONER - O ESM'T - NOTE: BUILDER TO MAINTAIN 3.0' BETWEEN A/C PAD AND PROPERTY LINE. BUILDERS ENDORSEMENT SIGNED: NAME: DATE: OFFICE COPY 'p yl c NOTE -ALL BUILDING TIES ARE MEASURED TO THE FOUNDATION WALLS. OFFICE COPY ALL PAVERS ALL MEASUREMENTS ESTIMATED FRONT 456± SQ. FT. BACK 224± SQ. FT. TREE SCHEDULE LOT SQ. FT. MINUS EASEMENTS/WETLANDS 6,600 ACRES=6,600/43,560 0.15 ACRESx40=REQUIRED TREE INCHES 6.0 THE REQUIRED NUMBER OF TREE INCHES WILL BE MET USING 2" DIAMETER TREES. 70% OF REQUIRED PLANTED TREES SHALL BE CANOPY TYPE, WITH NO MORE THAN 50% OF THE SAME SPECIES. THE LOT SHOWN HEREON IS IN THE SPECIAL FLOOD HAZARD ZONE "X" AS SHOWN ON FLOOD INSURANCE RATE MAP 0405 H FOR THE CITY OF JACKSONVILLE, FLORIDA, DATED 06-03-13 ALL AMERICAN SURVEYORS OF FLORIDA, INC. LAND SURVEYORS - 3751 SAN JOSE PLACE SWTE 15 - JACKSONVILL& FLORILK 32257 - 904/279-0088 - LICENSED LAND BUSINESS NO. 3857 Le end COV. - COVERED F.F.E. + FINISH FLOOR ELEVATION �O _ 5 FND. - FOUND ASC r NR CONDITIONER - O ESM'T - SEMENr I.D. r IDENTIFICATION SKETCH FOR PLOT PLAN ONLY -DOES NOT REPRESENT OR PURPORT TO SHOW OFFICE COPY ALL PAVERS ALL MEASUREMENTS ESTIMATED FRONT 456± SQ. FT. BACK 224± SQ. FT. TREE SCHEDULE LOT SQ. FT. MINUS EASEMENTS/WETLANDS 6,600 ACRES=6,600/43,560 0.15 ACRESx40=REQUIRED TREE INCHES 6.0 THE REQUIRED NUMBER OF TREE INCHES WILL BE MET USING 2" DIAMETER TREES. 70% OF REQUIRED PLANTED TREES SHALL BE CANOPY TYPE, WITH NO MORE THAN 50% OF THE SAME SPECIES. THE LOT SHOWN HEREON IS IN THE SPECIAL FLOOD HAZARD ZONE "X" AS SHOWN ON FLOOD INSURANCE RATE MAP 0405 H FOR THE CITY OF JACKSONVILLE, FLORIDA, DATED 06-03-13 ALL AMERICAN SURVEYORS OF FLORIDA, INC. LAND SURVEYORS - 3751 SAN JOSE PLACE SWTE 15 - JACKSONVILL& FLORILK 32257 - 904/279-0088 - LICENSED LAND BUSINESS NO. 3857 Le end COV. - COVERED F.F.E. + FINISH FLOOR ELEVATION _ 5 FND. - FOUND ASC r NR CONDITIONER - ESM'T - SEMENr I.D. r IDENTIFICATION SKETCH FOR PLOT PLAN ONLY -DOES NOT REPRESENT OR PURPORT TO SHOW 1-4 CONIC - C NCRETE P.R.M. r PERMANENT REFERENCE MONUMENT BOUNDARY LINES NOR IS IT BASED ON A FIELD RUN SURVEY - MON. - I.P. - IR NUMEM N PIPE P.T. + POINT OF TANGENCY I.R. - IR)N ROD P.C.P. r PERMANENT CONTROL POINT ALL o cAM LTA ANGLE P.C. +MINT OF CURVE P.R.C. r POINT OF REVERSE CURVE AMERICAN C LDENGTH P.C.C. . POINT OF COMPOUND CURVE B.R.L + BUILDING RESTRICTION SURVEY NOT VALID UNLESS EMBOSSED BY SEAL SURVEYORS - RADIUS ( .) - CALCULATED F.P.&L. POWER a LIGHT JAMES D. HARRISON, JR., No. 2647 OF FLORIDA ) r TYPICAL MICHAEL A. GARRETT, No. 8643 /NC. P T R IAL LINE 'i - C NITER UNE NGVD . NATIONAL GEODETIC VERTICAL DATUM HAVO + NORTH AMERICAN VERTICAL 1':20' SCALE R/W - RI -HT-OF-WAY - POA�'--/ E P.I. „ DA UTM OF INTERSECTION - 9 - -Y- (W) - WIrNESS EOW r EDGE OF WATER Toa +TOP of BANK - DATE 06-05-18 FLOR A GISTERED S VEYOR AWMAPPER _-8 F. B. X DR. BY BRB DIR. P:\2018\84288-164361 -plotplan ORDER N0. 164361 FILE 84288 OFFICE COPY FIRST FLOOR LAYOUT SCALE: 1/4" = 1'011 ,BCS BUILDING COMPONENT SUPPLY, INC, 4527 JP HALL BLVD. SUITE 208 GREEN COVE SPRINGS, FL 32043 O: 904.297.9390 F: 904.529.1406 S THIS IS A TRUSS PLACEMENT DIAGRAM ONLY. These trusses are designed as individual building components to be incorporated into the building design at the specification of the building designer. See individual design sheets for each truss design identified on the placement drawing. The building designer is responsible for temporary and permanent bracing of the roof and floor system and for the overall structure. The design of the truss support structure including headers, beams, walls, and columns is the responsibility of the building designer. For general guidance regarding bracing, consult "Bracing of Wood Trusses" available from the Truss Plate Institute, 583 D'Onifrio Drive; Madison, WI 53179. ATTENTION. Refer to truss layout and engineering documents that arrive with delivered field trusses. Unless noted otherwise, all beams are by others. REVISION DATE CHECKED BY 00/00/1 5 CLIENT 1 TOLL BROTHERS SUBDIVISION I ATLANTIC BEACH MODEL 1 CAPTIVA ELEVATION 1 CARIBBEAN LOT # DRAWN BY CJR 111 DATE D6'R9F#O,8 16156TO