577 COASTAL OAK LN - FINAL SURVEY 10-3-18MAP SHOWING AS -BUILT SURVEY OF
LOT 87 AS SHOWN ON MAP OF
ATLANTIC BEACH COUNTRY CLUB UNIT 2
AS RECORDED IN PLAT BOOK 67 PAGES 132— 137 OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLA.
CERTIFIED TO: CHARLES H. BLOODWORTH, 111 AND MARGARET A. BLOODWORTH
TBI MORTGAGE COMPANY
WESTMINISTER TITLE AGENCY, INC
CHICAGO TITLE INSURANCE COMPANY
CURVEDATA Cl
S81'12' 0"W
CH = 45.81'
R = 300.00'
A = 45.86'
/, = 08'45'30"
O
Do N
T_
t
CD
GOLF COURSE
N85'35'25"E
27.03'
LOT 8 7
19.7'
A .i/
1
10' B.R.L.
25.6' \ 1'
4'X4'
CONCRETE
A/C PAD
0.6' WIDE 1
WOOD WALL
ONE STORY
WOOD FRAME
RESIDENCEmo
ADDRESS
FFE=3 30'
CURVE DATA C2
N81 *38'28"E
CH = 24.79'
R = 180.00'
A = 24.81'
z = 07'53'55"
•
—�1 dP
M�
O LEAD
WALK
COASTAoL OAKLANE
(RIGHT
r,7T 7 ^..'1"9
GONCRE M
TRANSF DR
pA
0.),10 ,
x10 MENT
EQUIP ENT
1 \
A=6�NPIL�
5& T
DISK?
LB #3g5
BENCHMARK:
NORTH RIM OF PEGGED
MANHOLE ® CLI OF ATLANTIC
BEACH DRIVE & COASTAL
OAKS LANE
ELEVATION: (7.92)
ELEVATIONS SHOWN HEREON
REFER TO NGVD OF 1988
DENOTES FND X -CUT
® IN CONCRETE NO I.D.
UNLESS OTHERWISE NOTED
DENOTES FOUND 1/2"
O IRON PIPE LB 3848
UNLESS OTHERWISE NOTED
WM - DENOTES WATER METER
® - DENOTES BRICK PAVERS
FINAL; W.O. 0166617; 9-10-18 (FIELD) (12.0) - DENOTES PRE- ELEVATIONS
FOUNDATION, F.F.E.; 1.0.0 162178; 3-14-18 (FIELD) �Q - DENOTES POST- ELEVATIONS
LOT & HOUSE S-0(GOO) SET F.F.E.) W.0.0161619: 2-21-18 (FIELD)
THIS SURVEY WAS PERFOR ED WITHOUT THE BENEFIT OF A TITLE COMMITMENT. DENOTES DIRECTION OF FLOW
THERE MAY BE ADDITIONAL EASEMENTS AND/OR RESTRICTIONS THAT ARE NOT SHOWN
ON THIS SURVEY THAT MA" BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY.
THE LOT SHOWN HEREON IS IN THE SPECIAL FLOOD HAZARD ZONE "X" AS SHOWN
ON FLOOD INSURANCE RATE MAP 0406 H FOR THE CITY OF JACKSONVILLE, FLORIDA, DATED 06-03-13
ALL AMERICAN SURVEYORS OF FLORIDA, INC.
LAND SURVEYORS — 3751 SAN JOSE PLACE, SUITE 15 — JACKSONVILLE, FLORIDA, 32257 — 904/279-0088 — LICENSED LAND BUSINESS NO. 3857
I N
F.F.E. - FINISH FLOOR ELEVATION
W
= COVERED
I11
0 O
Q
FOUND
1. D. IDENTIFICATION
m�
= EASEMENT
CONCRETE
P.R.M. PERMANENT REFERENCE
MON.
MONUMENT
MONUMENT
LP.
- IRON PIPE
P.�f_ POINT OF TANGENCY
P. - PERMANENT CONTROL POINT
A
= DELTA ANGLE
P.C. POINT OF CURVE
m Z
= CHORD
P.R.C. POINT OF REVERSE CURVE
A
OVERED
P.C.C. POINT OF COMPOUND CURVE
BRICK
B.R.L. = BUILDING RESTRICTION
'CALL.) = CCALCULATED
F.P.&L.= FLORIDA POWER & LIGHT
(D)
DEED
('�P.) - TYPICAL
P
PLAT
115.5'7.7' M
R
RADIAL LINE
ri _ _
L _ — 20' B.R.L.
= CENTER LINE
NAVD - NORTH AMERICAN VERTICAL
15.9'
RIGHT-OF-WAY
DATUM
FENCE
O
BRICK PAVE
To
—
DRIVEWAY
7.5' JE A �j3J
EASEMENT
S85'35 25 W
FND I/
WM 37.84'
IRON PIPE
LB 6696
CURVE DATA C2
N81 *38'28"E
CH = 24.79'
R = 180.00'
A = 24.81'
z = 07'53'55"
•
—�1 dP
M�
O LEAD
WALK
COASTAoL OAKLANE
(RIGHT
r,7T 7 ^..'1"9
GONCRE M
TRANSF DR
pA
0.),10 ,
x10 MENT
EQUIP ENT
1 \
A=6�NPIL�
5& T
DISK?
LB #3g5
BENCHMARK:
NORTH RIM OF PEGGED
MANHOLE ® CLI OF ATLANTIC
BEACH DRIVE & COASTAL
OAKS LANE
ELEVATION: (7.92)
ELEVATIONS SHOWN HEREON
REFER TO NGVD OF 1988
DENOTES FND X -CUT
® IN CONCRETE NO I.D.
UNLESS OTHERWISE NOTED
DENOTES FOUND 1/2"
O IRON PIPE LB 3848
UNLESS OTHERWISE NOTED
WM - DENOTES WATER METER
® - DENOTES BRICK PAVERS
FINAL; W.O. 0166617; 9-10-18 (FIELD) (12.0) - DENOTES PRE- ELEVATIONS
FOUNDATION, F.F.E.; 1.0.0 162178; 3-14-18 (FIELD) �Q - DENOTES POST- ELEVATIONS
LOT & HOUSE S-0(GOO) SET F.F.E.) W.0.0161619: 2-21-18 (FIELD)
THIS SURVEY WAS PERFOR ED WITHOUT THE BENEFIT OF A TITLE COMMITMENT. DENOTES DIRECTION OF FLOW
THERE MAY BE ADDITIONAL EASEMENTS AND/OR RESTRICTIONS THAT ARE NOT SHOWN
ON THIS SURVEY THAT MA" BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY.
THE LOT SHOWN HEREON IS IN THE SPECIAL FLOOD HAZARD ZONE "X" AS SHOWN
ON FLOOD INSURANCE RATE MAP 0406 H FOR THE CITY OF JACKSONVILLE, FLORIDA, DATED 06-03-13
ALL AMERICAN SURVEYORS OF FLORIDA, INC.
LAND SURVEYORS — 3751 SAN JOSE PLACE, SUITE 15 — JACKSONVILLE, FLORIDA, 32257 — 904/279-0088 — LICENSED LAND BUSINESS NO. 3857
F.B. PRINT I DR. BY THG\TTH
THIS IS TO CERTIFY THAT THE ABOVE LANDS WERE SURVEYED UNDER MY RESPONSIBLE
SUPERVISION AND DIRECTION, THAT THERE ARE NO ENCROACHMENTS EXCEPT AS SHOWN
AND THAT THE SURVEY SHOWN HEREON MEETS THE MINIMUM TECHNICAL STANDARDS
SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL SURVEYORS AND MAPPERS
PURSUANT TO CHAPTER 472.027 / CHAPTER 61G17-6, FLORIDA STATUTES.
SCALE 1`20'
DATE 09-10-18
DIR. P:\2017\82968
SURVEY NOT VALID UNLESS EMBOSSED BY SEAL
JAMES D. HARRISON. JR., No. 2647
MICHAEL A. GARREIT, No. 6643
FLORIDA REGISTERED SJRVEYOR Af MAPPER
ORDER NO. 166617—FNL
I— 4I
ALL
AMERICAN
SURVEYORS
OF FLORIDA,
INC.
I_ 8)
FILE 82968
F.F.E. - FINISH FLOOR ELEVATION
COV.
= COVERED
AIC = AIR CONDITIONER
FND.
FOUND
1. D. IDENTIFICATION
ESM'
CONC
= EASEMENT
CONCRETE
P.R.M. PERMANENT REFERENCE
MON.
MONUMENT
MONUMENT
LP.
- IRON PIPE
P.�f_ POINT OF TANGENCY
P. - PERMANENT CONTROL POINT
A
= DELTA ANGLE
P.C. POINT OF CURVE
CH
= CHORD
P.R.C. POINT OF REVERSE CURVE
A
ARC LENGTH
P.C.C. POINT OF COMPOUND CURVE
IUS
B.R.L. = BUILDING RESTRICTION
'CALL.) = CCALCULATED
F.P.&L.= FLORIDA POWER & LIGHT
(D)
DEED
('�P.) - TYPICAL
P
PLAT
MD - NATIONAL GEODETIC VERTICAL
R
RADIAL LINE
DATUM
= CENTER LINE
NAVD - NORTH AMERICAN VERTICAL
R/W
R/W
RIGHT-OF-WAY
DATUM
FENCE
P.I. - POINT OF INTERSECTION
EOW - EDGE OF WATER
(W)
WRNESS
TOB = TOP OF BANK
F.B. PRINT I DR. BY THG\TTH
THIS IS TO CERTIFY THAT THE ABOVE LANDS WERE SURVEYED UNDER MY RESPONSIBLE
SUPERVISION AND DIRECTION, THAT THERE ARE NO ENCROACHMENTS EXCEPT AS SHOWN
AND THAT THE SURVEY SHOWN HEREON MEETS THE MINIMUM TECHNICAL STANDARDS
SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL SURVEYORS AND MAPPERS
PURSUANT TO CHAPTER 472.027 / CHAPTER 61G17-6, FLORIDA STATUTES.
SCALE 1`20'
DATE 09-10-18
DIR. P:\2017\82968
SURVEY NOT VALID UNLESS EMBOSSED BY SEAL
JAMES D. HARRISON. JR., No. 2647
MICHAEL A. GARREIT, No. 6643
FLORIDA REGISTERED SJRVEYOR Af MAPPER
ORDER NO. 166617—FNL
I— 4I
ALL
AMERICAN
SURVEYORS
OF FLORIDA,
INC.
I_ 8)
FILE 82968