283 BELVEDERE ST - FINAL SURVEY 10-3-18MAP SHOWING BOUNDARY & ASBUILT SURVEY OF
SOUTHERLY 1/2 LOT 455 AND LOT 456
AS SHO WN ON MAP OF
SAL TAIR SECTION 1
AS RECORDED IN PLAT BOOK 10 PAGE 8 OF THE PUBLIC RECORDS OF DUVAL COUNTY, FLA.
CERTIFIED TO: JAX ELITE REALTY
/
/
W /
m o /
0
z
j O
rg `
In N 575.
00 '00-C
/Op•Op,
9.7-�
o IvDERF.
SQ.
28.7' Zso °F
U WOOF 4' / 0
0 F OT 455/
°�L fNCe T
8 /V75.
O N 10. v 100
000
9.71 ^ g 21.9 • 101* Rf rf NTI�� dt 5 \ W70.
OOD OF 4.
`0 m/ 9.4 SQVT B R'C. 10. �\ ENCE
9. /h4 \� M
F HERCY ilsoM�
2( v 46 3 10.� i Q T 2 19.8 �9.9 \ 9 W p 3 w o45.5 O
9.71 .9\ , 5.7. opERED 80.2 r9.6 ^ } �v v
Q 3.� 1Ry / `9.8 $ o
r•, o�`
\ h y x10.0 9.6t /.7 N ^ a ~
N7 1.6 "� {! No
of s 6.7• / ° S DO.Op W 10.4 Q 9.81 / 9.6 �y 3 0
3 ONE STO '00.op\ f 10.2 O J
10.1j Ry F
7ESIDEIy 19
CE .
777. Kid
Rh O
o,r` ,:� s. �• DR'
;- :Q �?,:.•,:: r - ;- SS # 283 0.. o. =19.4•
CP
0
CWP \ 6 j9,8 110.1 110.1 110.3 It 0.0 4 zovlui
9.x 2 10.7J10.71 10.E :� o O
n 1101 010.0 48.3• 5
9 Z
9. FND 1 j10. 0 10.0 0 � 3 A �O
No 1. D /4 /. P. l 31.9' I vi rF
6 4.8 0OP 2 x \BRC O 10.2 X9.7 1 f9 7 2
WOOD, 0 x ` M l9.5 9 5
N S x'00\ x \ O
�I '0 9 /
QQ
`Q, -DENOTES 12" WOOD POWER POLE ~ -DENOTES BENCHMARK:
00.0' -DENOTES TOPOGRAPHIC SPOT ELEVATION (GROUND SHOT) FND NAIL & DISK
LB 3857
-DENOTES CATCH BASIN ELEVATION: (9.74)
EZ -DENOTES CONCRETE ELEVATIONS SHOWN HEREON
ADD NEW LOT GRADES; W.O.# 167247; 09-27-18 (FIELD) REFER TO NAVD OF 1988
FINAL; W.O.# 164508; 06-15-18 (FIELD) NOTE:
LOT & HOUSE STAKE OUT (GOOD -SET F.F.E.); W.O.# 161216; 02-08-18 (FIELD) SIDE/FRONT BUILDING TIES ARE
ADDED FFE TO DRAWING 111-07-2017 (OFFICE) TO THE FOUNDATION.
LOT & HOUSE STAKE OUT (GOOD -SET F.F.E.); W.O.# 158484; 09-25-17 (FIELD)
THIS SURVEY WAS PERFORMED WITHOUT THE BENEFIT OF A TITLE COMMITMENT.
THERE MAY BE ADDITIONAL, EASEMENTS AND/OR RESTRICTIONS THAT ARE NOT SHOWN UNDERGROUND ENCROACHMENTS NOT LOCATED
ON THIS SURVEY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY.
THE LAND SHOWN HEREON IS IN THE SPECIAL FLOOD HAZARD ZONE "X" AS SHOWN
ON FLOOD INSURANCE RATE MAP 0409H FOR DUVAL COUNTY, FLORIDA, F.I.R.M INDEX DATE 06-03-13
ALL AMERICAN SURVEYORS OF FLORIDA, INC.
LAND SURVEYORS - 3751 SAN JOSE PLACE, SU17E 15 - JACKSONVILL.E. FLORIDA 32257 - 904/279-0088 - UCENSED LAND BUSINESS N0. 3857
FND FOUND L d
I.D.
-DENOTES FND (NAIL & DISK
^ 0'00' \
OCT 3 2018
B 5879
A/C - AIR CONDITIONER
.91
1-51
UNLESS OTHERWISE NOTED
73.
BOC = BACK of curse
=
N.G. NATURAL GROUND
Q
-DENOTES FND 1/2" I.P.
WOOD F- '
aowN
Tw - TOP OF WALL
UNLESS OTHERWISE NOTED
-
o
CRB
-DENOTES CABLE RISER BOX
O
2 o O)
o O
TRB
-DENOTES TELECOM RISER BOX
P.T.= POINT OF TANGENCY
P.C.P. = PERMANENT CONTROL POINT
TO CHAPTER 472.027 / CHAPTER 61G17-6, FLORIDA STATUTES.
WM
-DENOTES WATER METER
RALDIUS ULATED
P.C. - POINT OF CURVE
`Q, -DENOTES 12" WOOD POWER POLE ~ -DENOTES BENCHMARK:
00.0' -DENOTES TOPOGRAPHIC SPOT ELEVATION (GROUND SHOT) FND NAIL & DISK
LB 3857
-DENOTES CATCH BASIN ELEVATION: (9.74)
EZ -DENOTES CONCRETE ELEVATIONS SHOWN HEREON
ADD NEW LOT GRADES; W.O.# 167247; 09-27-18 (FIELD) REFER TO NAVD OF 1988
FINAL; W.O.# 164508; 06-15-18 (FIELD) NOTE:
LOT & HOUSE STAKE OUT (GOOD -SET F.F.E.); W.O.# 161216; 02-08-18 (FIELD) SIDE/FRONT BUILDING TIES ARE
ADDED FFE TO DRAWING 111-07-2017 (OFFICE) TO THE FOUNDATION.
LOT & HOUSE STAKE OUT (GOOD -SET F.F.E.); W.O.# 158484; 09-25-17 (FIELD)
THIS SURVEY WAS PERFORMED WITHOUT THE BENEFIT OF A TITLE COMMITMENT.
THERE MAY BE ADDITIONAL, EASEMENTS AND/OR RESTRICTIONS THAT ARE NOT SHOWN UNDERGROUND ENCROACHMENTS NOT LOCATED
ON THIS SURVEY THAT MAY BE FOUND IN THE PUBLIC RECORDS OF THIS COUNTY.
THE LAND SHOWN HEREON IS IN THE SPECIAL FLOOD HAZARD ZONE "X" AS SHOWN
ON FLOOD INSURANCE RATE MAP 0409H FOR DUVAL COUNTY, FLORIDA, F.I.R.M INDEX DATE 06-03-13
ALL AMERICAN SURVEYORS OF FLORIDA, INC.
LAND SURVEYORS - 3751 SAN JOSE PLACE, SU17E 15 - JACKSONVILL.E. FLORIDA 32257 - 904/279-0088 - UCENSED LAND BUSINESS N0. 3857
FND FOUND L d
I.D.
eg�
= IDENTIFICATION
CONC = CONCRETE
= TYPICAL
A/C - AIR CONDITIONER
THIS IS TO CERTIFY THAT THE ABOVE LANDS WERE SURVEYED UNDER MY RESPONSIBLE
1-51
(P.P)
= RON PIPE
BOC = BACK of curse
=
N.G. NATURAL GROUND
SUPERVISION AND DIRECTION, THAT THERE ARE NO ENCROACHMENTS EXCEPT AS SHOWN
-4
I.R.
= IRON ROD
Tw - TOP OF WALL
AND THAT THE SURVEY SHOWN HEREON MEETS THE MINIMUM TECHNICAL STANDARDS SET
-
0
CH
= DELTA ANGLE
CHORD
ew - BOTTOM OF WALL
FORTH BY THE FLORIDA BOARD OF PROFESSIONAL SURVEYORS AND MAPPERS PURSUANT
A
= ARC LENGTH
P.T.= POINT OF TANGENCY
P.C.P. = PERMANENT CONTROL POINT
TO CHAPTER 472.027 / CHAPTER 61G17-6, FLORIDA STATUTES.
ALL
(C)
RALDIUS ULATED
P.C. - POINT OF CURVE
AMER/CAN
(D)
= DEED
P.R.C. POINT OF REVERSE CURVE
SURVEYORS
P.C.C. - POINT OF COMPOUND CURVESURVEY
NOT VALID UNLESS EMBOSSED BY SEAL
SP2
` PLAT
B.R.L. = BUILDING RESTRICTION LINE
OF FLORIDA,
R
= RADIAL LINE
F.P.&L.= FLORIDA POWER & LIGHT
JAMES D. HARRISON, SIR.. No. 2647
INC.
i
R/W
(A)
= CENTER LINE
= RIGHT-OF-WAY
CTUAL
=AATIONAL
-x- = FENCE
LB = LIC BUSINESS
NGVD = NATIONAL GEODETIC VERTICAL
MICHAEL A. GARRETT, NO.. 664-1
SCALE 1 "=20' % L" w s'
(W)
WITNESS
DATUM
F.F.E.
= FINISH FLOOR ELEVATION
NAVE, - NORTH AMERICAN VERTICAL DATUM,�
-�
9
W
= WIDTH
P.I. = POINT OF INTERSECTION
(} .� �• f �.-y.`•-".."""`�
-
D
MES
- DEPTH
- MITERED END SECTION
EOW - EDGE OF WATER
TOB = TOP OF BANK
DATE 06-15-18 ��
FLORIDA_REGISTERED SL*EYOR AWr MAPPER
-8
FQ
AI /n
n n R9RAZ-1 F77A7
'A n io,-..,•, ----
I'll. ' . --- UKUtK NU. - FILE .....