Loading...
229 PIne ROW18-0033 ;,;51-0-% City of Atlantic Beach APPLICATION NUMBER js.' :��?� Building Department (To be assigned by the Building Department.) 800 Seminole Road ECEIVE G �� Atlantic Beach, Florida 32233-5445 �/ 1 © ��0 � Phone(904)247-5826 • Fax(904) -58 EP 2 6 2018 _AM E-mail: building-dept@coab.us Date routed: ZS City web-site: http://www.coab.us BY: APPLICATION REVIEW AND TRACKING FORM Department review Property Address: Z z� I f�C ( required Yes No S p Building Applicant: A rfilaTining &Zoning t Tree Adm— iinistrator Project: 3 v0 CSO (--)0 L E -•'liC WON( :• is i i i les Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. I (Denied. I Not applicable (Circle one.) Comments: BUILDING PLANNING & ZONING �` �J Reviewed by: led Date: /•400 TREE ADMIN. Second Review: Approved as revised. I (Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. nDenied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 s \,yr City of Atlantic Beach APPLICATION NUMBER ! ,js ; f�.) Building Department (To be assigned by the Building Department.) r `SII 800 Seminole Roadlir ( � G �O0 �r Atlantic Beach, Florida 32233-5445 ?::?cD `� ( © 3 Phone(904)247 5826 Fax(904) 247 5845 Dril!P E-mail: building-dept@coab.us Date routed: / 2 S� City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM I ( S ( Department review required Yes No `� Property Address: Z j 3C- A Building Applicant: �l �nning &Zoning Tree Administrator Project: 3 (SCO f PO I_ ec orc ` PtfiTc utile ies� Public Safety Fire Services • Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. I 'Denied. I INot applicable (Circle one.) Comments: BUILDING PLANNING & ZONING y_�� �l� fa-9-r 8 Reviewed b Date: TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. I !Denied. FINot applicable Comments: Reviewed by: Date: Revised 05/19/2017 o ‘iv (8 - 663 3 rte. RIGHT-OF-WAY/ EASEMENT PERMIT Permit#Issued by the City of Atlantic Beach • PERMITTEE RESPONSIBLE FOR NOTIFYING SI I AND OBTAINING UTILITY LOCATES Job Address 1Z9 / C e _.S Phone 66 -779 Permittee 0.-r4 Email 5%6+rp ,4—, Requesting Permission to Construc _ 'SIA I I(/> 33 /woad /e rlrve Location(Reference to Cross-Street) Del v 1 S t • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement,maintenance, safe and efficient operation, alteration or relocation of all,or any portion of said street or easement as determined by the Director of Public Works,any or all said poles,wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of g, (Project Superintendent) with Company Name ,TE74 Phone 6 6f-22? • All materials and equipment shall be subject to inspection by the Director of Public Works. • All city property shall be restored to its original condition as far as practical, in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • The permittee shall commence actual construction in good faith within days. If the beginning date is more than 60 days from date ofpermit approval then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,title and interest in the land to be entered upon and used by the holder,and the holder will,at all times, assume all risk of and indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. • The Director of Public Works shall be notified twenty-four(24)hours prior to starting work and again immediately upon completion. Date Permittee(signed in presence of Notary Public) STATE OF FLORIDA,COUNTY OF DUVAL • The foregoing instrument was acknowledged this day of ,20 by ,who personally appeared before me and (printed name of Permittee) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. Personally Known Signature of Notary Public,State of Florida Produced Identification(Type) JUI CUE Reports Estimate Number:35322 235 PINE ST./35/4W INSTALL Estimate Type:SR Contract:089-16-HM OH FY18 Estimate Version: By: SIMPRB MWO#/Task:30343268 Required Date: Oracle Project#:8004473 Estimated On: 09/05/2018 Cost Estimate Materials JEA Contractor 1.New Material Cost(WI sales tax) $452.46 $452.46 2.Transformer Cost(w/sales tax) $0.00 $0.00 3.Returned Material Salvage Value $0.00 $0.00 Labor 4.Crew Time $281.02 $748.50 5.Extraordinary Costs $0.00 $0.00 JEA Overhead 6.Fringe Benefits(54.56%of lines 4&7) $196.18 $114.14 7.Engineering Costs(Variable%of line 4) $78.55 $209.21 8.Project Equipment Costs(40%of total equipment costs) $162.46 $0.00 9.Material Handling(8.30%of lines 1&2) $37.55 $37.55 10.Inspection(6.84%of line 4) $0.00 $51.20 11.Total Cost of Project $1,208.22 $1,613.06 12.Work Order Estimate(Line 11 minus line 8,9,&10) $1,008.21 $1,575.50 13.Billable Equipment Depreciation(60%of total equipment costs) $243.69 $0.00 14.Billing Estimate(Including Transformer Cost)(Lines 11+13+(58.71%of 4&7)) $1,663.01 $1,735.88 15.Billing Estimate(W/O Transformer Cost)(Lines 11+13+(58.71%of 4&7)-Line 2) $1,663.01 $1,735.88 • Time Estimate Crew Hours Total Manhours 2.25 9.01 JEA CUE Reports Estimate Number:35322 235 PINE ST./35/4W INSTALL Estimate Type:SR Contract:089-16-HM OH FY18 Estimate Version: By: SIMPRB MWO#/Task:30343268 Required Date: Oracle Project#:8004473 Estimated On: 09/05/2018 Conductor, Conduit and Pipe Detail Quantities From Station To Station CU Build Transfer Remain Remove 01 2 C.2/OP 60 0 0 0 CUE Reports Estimate Number:35322 235 PINE ST./35/4W INSTALL Estimate Type:SR Contract:089-16-HM OH FY18 Estimate Version: By: SIMPRB MWO#/Task:30343268 Required Date: Oracle Project#:8004473 Estimated On: 09/05/2018 CU Summary CU Name Quantity Description C.2/0P 60 2/0 AAC PAP W/2/0 AAAC NEUTRAL G3W*2 1 WOOD POLE-NON-EQUIPMENT GROUND GY3*5 1 GY3*5 3/8" DOWNGUY W/8 FT SCREW ANCHOR P.35/4W 1 35 FT. CLASS 4 WOOD POLE RUBUP 4 LINE RUBBER INSTALLATION, PER SECT. S20ES*2/0-2/0 1 SECONDARY CONNECTION AT POLE S4*210 2 SECONDARY DEADEND CU Name Quantity Description RUBDOWN 4 LINE RUBBER REMOVAL, PER SECT. V-tvp,y,, City of Atlantic Beach APPLICATION NUMBER jt Building Department (To be assigned by the Building Department.) r J�tt' rCEIVEI)800 Seminole Road C ( , ^, rd____. �r Atlantic Beach, Florida 32233-5LJ J 1 Q - Oo33 Phone(904)247-5826 • Fax(9 �}52 6 2018J3�9r. Email: building dept@coab.usC- Date routed: Z ( �City web-site: http://www.coab BY' APPLICATION REVIEW AND TRACKING FORM Property Address: zpi N.DG ..s Department review required Yes No Building Applicant: A Inning &Zoning A , Tree Administrator Project: �� "� 00 �O L E is or< Plic Uti i ies.) Public Safety Fire Services � Review fee $ Dept Signature �:w' Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLION STATUS Reviewing Department First Review: Approved. Denied. I 'Not ppli ble (Circle one.) Comments: BUILDING PLANNING &ZONING - (--A-----.2---.1`----Date: /0—K(-er--- Reviewed by: � TREE ADMIN. Second Review: Approved as revis d. ❑Denied. ['Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. ['Denied. ['Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 , r , -...i.,•' A / ...n , . ...---.._ Al AO - 1144 4 Pi /i ..a- .„ -. A •' ----- '"'' 4700' ' ,' .,.. „ . _ / ,.,, ,,,,.. .,.. .• ,, ''''. .::,•' . ., -. - -....-/ . .1411fr% ,.;.•. .111:1 ,.,' ''''.'". -....__ , . -.< . . ' / i . , .. . ,1 4. • . ••-„,„_,,.„. ,.. I .., . . ., A' .. . .... . , -1- IT,A ' "s7( ,. :4: : .• ..or 4., . . - • ,.. .,• .. ......,.givt - ': .• # 'Si - ,ir.:NI. • . ' Ix- ,i :- ' --,-.....„ • - t• • . ‘1 , ,•-• , it :, ,,,, ..,,. . • ..,,,.. - - 4 , ., ;....€ • * ;' -a ,tr t;-41,,,,,-.. •., .., . ' c ,.. • .:. ,, Hs, - • -1.-,-------,fi ' : • 4 •/ , • . --...,,,, ',011P. '' .: J.; - • --- # - . - '77 f ---- --._ / • '"'i ,'• ','We . 'Y''''''#''°''.- - '1 . 4--tt t##-• , / . g'''' -......,.., -'- -=Z:<,fiLf!t" I'l, 4 •* --__ , - , ......_, -....., / t .., ,.. -Nrt. •----- ,,-, a. ' ' ' -- ,, ,t -.-,.,, • , ; ,... *. , . -„,.... • . . \ ,....„, 41. IP, --,--/ ; e V ---.,---- / .-------. . _ -,_ ,„, ........ . .. *„._... ,,,,. . ,,,'. ,ff - A , ... . . :........„...„.. ,. ,..,„ 111, --,,, / -,,,.. , ti„ ...... . rist ,• . list :... .. - - A .4 0 lik'' , 4 ...2 :. ., - 0 - - ' 'NO • ;.::' ' , . • ,-7'.'.7'..7':"?:.'''''-• ':4 ,," / .f4, - I. / , -',' • . . ,.... ..:- - / -,....... --,.... .Ir - It '/ ---______ . . , AA. 1*-. liti. 4. : .„'' '': '',..,,4'-'• ' N 'lilt- ,,•••--, , ---,... ,- ... ...,_ / -----„, -.' -.'''-{: 11 -': - ': .,-.•'w:.---"'-' ''' ........_ . .. . . ... • - 7, A . , . ., . IPA . . #-',',, ,:--. .N'. " .-ic•-• ' ."-----..... . ,--... / ,..16.. ' •41 4.'1:' • .. ---/ . v..• . •-k- -,---- / it,._. t ' e. intilitk 1110 .1: A -.• "%"- ' 9£Z $ . 0 , P ' '. • . ' . 4,... - . 4.11 ' . 't 4-•-• 44-1 ---1; . -•;. ,,- i; .!..--1=. ,_-*". -,,,--i-1 • ,.-,--.4.-Ah ; ..„ m , •: , p-,17,-.,...,.. ,,, - .>, ......,„„.. i 14 ---,,,,,,• ... . itk•-,.',..., , --',.',4.7.... .. , .„.... .. - . .4 Srç, , 4111, -....... ..., / -`-...... '':*:-.''''.-•-- i -.... ''''' • ''''',...., Y, 1 I grai ., 0 Ita • ,,. , / ? "J. ..,...., . / - li / . VI1.-.--. , 4 ,, . .. ".....- ' • lib • .......... 4 ....' ll. 4...,.. _... ._., , • , ENGINEERING DESIGN ORACLE PERMIT MAXIMO DATE REL PROJECT#:35322 N.O.: 8004473 WO#: 30343268 CONST:09/6/18 CIR. TREE TRIMMING SUB-STA: NEPTUNE BEACH N.O.: 565 REQ'D:YES CELL ENGINEER:Robert SimpsonN,O„ N/A ZIP CODE: N/A CUSTOMER/ SVC PHONE LOCATION: 235 PINE ST./INSTALL 35/4W AND DROP 565 CENTER: SSSC N.O.:665-7793 1 STA 1. P# 235 PINE ST./ INSTALL ^� a„ / /e\/ 00 01 35/4W RUN 2/OP TO STA 2. N r / j e\/ r / / •/ STA 2, P# 234 PINE ST. • • OQ N�'�Na ***** ATLANTIC BEACH ZSeA'♦i r\' ' : /. .willilliglit'71k / _ j / Q / • N / mob`- b 252 / ILbh^Ob 1 : ti� N N. '� SOB .• 210? NNb,� 01 4 / Ii. t\ � STA 2 . N v.. //' STA 1 00 eN,in h A O N 0 / ,::1) Or 4 \ �r\ir''' It -/ b• hN to 260 / k 1. • Z joP ' o ``/ SOC I. '� • ~\ I\ o NN NN o / V '`^� NN� Q / A. ,� 216~ a,/ / ,?r tt / 107- 6 N 'aOB • i NN_ ,, \o • C• Z) N ` / r ~\ // �� NNS ti� / 4 ko Vo / oT . IL �•� m A. N 0 SC w / .- 0 96 oo q_ �. i� ... N S53 a /' / 0 /m S1 •4q b ~ r / �"%. //Or I/ij/ W • / oI/i A. �• /0 'I ~ '� op _Ot oo •qtty i JE It CUE Reports Estimate Number:35322 235 PINE ST./35/4W INSTALL Estimate Type:SR Contract:089-16-HM OH FY18 Estimate Version: By: SIMPRB MWO#/Task:30343268 Required Date: Oracle Project#:8004473 Estimated On: 09/05/2018 Cost Estimate Materials JEA Contractor 1.New Material Cost(w/sales tax) $452.46 5452.46 2.Transformer Cost(wl sales lax) $0.00 $0.00 3.Returned Material Salvage Value $0.00 $0.00 Labor 4.Crew Time $281.02 $748.50 5.Extraordinary Costs $0.00 $0.00 JEA Overhead 6.Fringe Benefits(54.56%of lines 4&7) $196.18 $114.14 7.Engineering Costs(Variable%of line 4) $78.55 $209.21 8.Project Equipment Costs(40%of total equipment costs) $162.46 $0.00 9.Material Handling(8.30%of fines 1&2) $37.55 $37.55 10.Inspection(6.84%of line 4) $0.00 $51.20 11.Total Cost of Project $1,208.22 $1,613.06 12.Work Order Estimate(Line 11 minus line 8,9,&10) $1,008 21 $1,575.50 13.Billable Equipment Depreciation(60%of total equipment costs) $243.69 $0.00 14.Billing Estimate(Including Transformer Cost)(Lines 11+13+(58.71%of 4&7)) $1,663.01 $1,735.88 15.Billing Estimate(W/O Transformer Cost)(Lines 11 +13+(58.71%of 4&7)-Line 2) $1,663.01 $1,735.88 Time Estimate Crew Hours Total Manhourt 2.25 9.01 i11 CUE Reports Estimate Number:35322 235 PINE ST./35/4W INSTALL Estimate Type:SR Contract:089-16-HM OH FY18 Estimate Version: By: SIMPRB MWO#/Task:30343268 Required Date: Oracle Project#:8004473 Estimated On: 09/05/2018 CU Detail Station:01 235 PINE ST. Build Transfer Remain in Place Remove C.2/OP 60 G3W 1 G3W*2 1 GY315 1 P.35/4W 1 S4`2/0 1 Station:2 234 PINE ST. Build Transfer Remain In Place Remove RUBUP 4 S20ES•2/0-2/0 1 S4'2/0 1 RUBDOWN 4 ti\) ( - bC)3 J RIGHT-OE-WAY/ EASEMENT PERMIT Permit#Issued by the City of Atlantic Beach PERMIT-TEE.RESPONSIBLE FOR NOTIFYING SI I AND OBTAINING UTILITY LOCATES Job Address 129 Pj je. ,S Y: Phone 66 - 3 Permittee o--u4 Email Srr►n b �q -- -- P r C"�.� _. .Low -- Requesting Permission to Construe - r'+Shr />sll� 53T"rvrlac Pv /e d-cirri? Location (Reference to Cross-Street) Det✓jd 51- • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair, improvement,maintenance, safe and efficient operation. alteration or relocation of all,or any portion of said street or easement as determined by the Director of Public Works, any or all said poles, wires,pipes,cables or other facilities and appurtenances authorized hereunder, shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of g, -S '� D.-n (Project Superintendent) with Company Name TE74 Phone to 65'-)7? 3^ • All materials and equipment shall be subject to inspection by the Director of Public Works. • All city property shall be restored to its original condition as far as practical, in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • The permittee shall commence actual construction in good faith within days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,title and interest in the land to be entered upon and used by the holder,and the holder will,at all times; assume all risk of and indemnify, defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. • The Director of Public Works shall be notified twenty-four(24) hours prior to starting work and again immediately upon completion. Date Perrnittee(signed in presence of Notary Public) STATE OF FLORIDA, COUNTY OF DUVAL The foregoing instrument was acknowledged this __day of ,20 by ,who personally appeared before me and (printed name of Permittee) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. Personally Known Signature of Notary Public,State of Florida Produced Identification(Type) JA CUE Reports Estimate Number:35322 235 PINE ST./35✓4W INSTALL Estimate Type:SR Contract:089-16-HM OH FY18 Estimate Version: By: SIMPRB MWO#/Task:30343268 Required Date: Oracle Project#:8004473 Estimated On: 09/05/2018 Material Summary Item Quantity Item Number Item Description 1 ANCSS002 ANCHOR, SCREW,SINGLE-HELIX, GALVANIZED 10"X 8'X 1-1/4", SHIP ON OPEN FLATBED ONLY! 1 BOLMS036 BOLT, MACHINE, 3/4"X 14", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 60 CAIOS002 CABLE, 2/0 (PAP), OVERHEAD SERVICE DROP,600 VOLT MULTIPLEX CABLE"MESA VERDE"PRE-ASSEMBLED PARALLEL SOUTHWIRE 61- 28-96-1, 1500 FOOT REELS 2 CLAGROO1 CLAMP,GROUND ROD, 5/8"-4SOL"HAMMERLOCK" 1 CLASR002 CLAMP,STRAIN RELIEF WEDGE,ALUMINUM, 1/0 TRI -4/0 PAP 2 CLASS004 CLAMP, STRAIGHT STRAIN,ALUMINUM, 5000#,4-3/0 ALUM 4 CNNCP002 CONNECTOR,#2, 6-2 MAIN, 2-1/0 TAP,ALUMINUM COMPRESSION, PARALLEL TAP, 3 CNNCP004 CONNECTOR,#4, 1/0-2/0 MAIN, 1/0-3/0 TAP COMPRESSION, PARALLEL TAP,ALUMINUM, 3 CNNVG003 CONNECTOR, 6-2 SOL/10-2 SOL,VISE GRIP PARALLEL, BRONZE 19 COBCO028 CONDUCTOR, #4 SOLID, SOFT DRAWN, BARE COPPER, 200',25#,ON PLASTIC REEL, 4"X 11.5"W/2"HOLE 140 COBCW014 CONDUCTOR, #4, TYPE 40 DSA, COPPERWELD&COPPERWELD- COPPER .204" DIAMETER 1480#BREAKING STRENGTH (50#COIL- 427' ) 2 COVIC002 COVER,"0" DIE, INSULATING,2-1/2" 2 GUAGW001 GUARD, GROUND WIRE, 1/2"X 1/2"X 96", GRAY PLASTIC 1 GUAGW002 GUARD,"YELLOW", GUY WIRE, 1/4"TO 1/2"8', POLYETHYLENE, USED ON ALL.3/8"AND 7/16"GUY STRANDS(DISTRIBUTION) 1 GUYAT008 GUY HOOK, COMBINATION,MALLEABLE OR DUCTILE IRON, HOT DIP GALV. 13/16" MOUNTING HOLE, 20,000 LB MIN. ULT.STRENGTH. FOR WOOD OR CONCRETE POLES 2 GUYGROO1 GRIP,GUY, 3/8", 26", GALVANIZED 50 GUYST005 STRAND, GUY,3/8"DIA, 7 PER STRAND, GALVANIZED STEEL, CLASS "B" GALV. OR BEZINOL IS ACCEPTABLE (500' COIL) 1 INSGB002 INSULATOR, STRAIN, GUY BREAKER, 21,000#RATED, 60"ROD LENGTH, FIBERGLASS FOR USE ON JEA'S DISTRIBUTION SYSTEM ONLY 2 INSS0002 INSULATOR,SUSPENSION, 4",CLASS 52-9 NEMA STRENGTH 10000#, GALV. FITTINGS 1 POLW0003 POLE,WOOD, 35'CLASS 4 (TIL=44), WEIGHT=1,026 LBS 2 RODGR003 ROD,GROUND, THREADLESS,5/8"X 8',SHIP ON OPEN FLATBED ONLY! 1 TAGH0007 ALUMINUM VERTICAL TAG HOLDER FOR ADHESIVE BACK CHARACTERS((NOT FOR"SLIDE IN"CHARACTERS)). 19.5"HIGH X 2" WIDE WITH 3-1/8"NAIL HOLES @ THE TOP AND THE BOTTOM. (PKG. OF 50 EACH) 1 WASRD005 WASHER, ROUND, 3/4"BOLT SIZE X 2"DIAMETER, GALVANIZED,' 500 EACH PER BOX "` 1 WASSF003 WASHER, SQUARE FLAT, 3"SQ X 1/4", 518"X 3/4"BOLT SIZE, GALVANIZED '' i CUE Reports Estimate Number:35322 235 PINE ST./35/4W INSTALL Estimate Type:SR Contract:089-16-HM OH FY18 Estimate Version: By: SIMPRB MWO#/Task:30343268 Required Date: Oracle Project#:8004473 Estimated On: 09/05/2018 Conductor, Conduit and Pipe Detail Quantities From Station To Station CU Build Transfer Remain Remove 01 2 C.2/0P 60 0 0 0 ii CUE Reports Estimate Number:35322 235 PINE ST./35/4W INSTALL Estimate Type:SR Contract:089-16-HM OH FY18 Estimate Version: By: SIMPRB MWO#/Task:30343268 Required Date: Oracle Project#:8004473 Estimated On: 09/05/2018 CU Summary BUILD CU Name Quantity Descriotion C.2/0P 60 2/0 AAC PAP W/2/0 MAC NEUTRAL G3W*2 1 WOOD POLE-NON-EQUIPMENT GROUND GY3'5 1 GY3'5 3/8"DOWNGUY W/8 FT SCREW ANCHOR P.35/4W 1 35 FT. CLASS 4 WOOD POLE RUBUP 4 LINE RUBBER INSTALLATION, PER SECT. S20ES*2/0-2/0 1 SECONDARY CONNECTION AT POLE S4*2/0 2 SECONDARY DEADEND REMOVE CU Name ti Description RUBDOWN 4 LINE RUBBER REMOVAL, PER SECT. .X CUE Reports Estimate Number:35322 235 PINE ST/35/4W INSTALL Estimate Type:SR Contract:089-16-HM OH FY18 Estimate Version: By: SIMPRB MWO#/Task:30343268 Required Date: Oracle Project#:8004473 Estimated On: 09/05/2018 1 WASSP002 WASHER,SPRING, 3/4"BOLT SIZE, DOUBLE COIL HELICAL TYPE, GALVANIZED(EXTRA HEAVY DUTY)