Loading...
1291 BEACH AVE - INTERIOR REMODEL PERMIT COAB Permit Form with Conditions Page 1 of 2 Enter Permit Number RES17-0311 I View Report J3 4 1 of 1 k Di 4 1000/0 v ..4- ;: rt"`''`% RESIDENTIAL PERMIT PERMIT NUMBER r°,•' ' CITY OF ATLANTIC BEACH RES17-0311 01/ 800 SEMINOLE ROAD ISSUED: 10/5/2018 EXPIRES:4/3/2019 ATLANTIC BEACH, FL 32233 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE:In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 129199 BEACH AVE RESIDENTIAL ALTERATION interior remodel $38000.00 RESIDENTIAL TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: 170295 0000 ATLANTIC BEACH COMPANY: ADDRESS: CITY: STATE: ZIP: STYLES CONSTRUCTION, JACKSONVILLE 1537 PENMAN RD SUITE A FL 32250 INC. BEACH OWNE12: ADDRESS: CITY: STATE: I ZIP: HIONIDES CHRIS C/O MARY C SORRELL ESQ ATLANTIC BEACH FL 32233 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list. Container cannot be placed on City right-of-way. FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $245.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $122.50 BUILDING PLAN REVIEW RESUBMITTAL SECOND 455-0000-322-1006 0 $50.00 BUILDING PLAN REVIEW RESUBMITTAL THIRD 455-0000-322-1006 0 $75.00 STATE DBPR SURCHARGE 455-0000-208-0600 0 $7.39 http://atlanticbeach.trakit.net/trakit/DocumentV fewer.aspx?&report=/Documents/PERMIT... 10/5/2018 COAB Permit Form with Conditions Page 2 of 2 I STATE DCA SURCHARGE I 45500002080700 I 0 I $4.931 Ir TOTAL:$504.82 yl 1 of 1 Issued Date:10/5/2018 http://atlanticbeach.trakit.net/trakit/DocumentViewer.aspx?&report=/Documents/PERNIIT... 10/5/2018 �tt..L�' City of Atlantic Beach APPLICATION NUMBER Js. , Building Department (To be assigned by the Building Department.) fil �.r 800 Seminole Road L I ,, �r Atlantic Beach, Florida 32233-5445 R C��� —C Phone(904)247-5826 - Fax(904)247-5845 on � E-mail: building-dept@coab.us Date routed: Ic\r 13-0 t + City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1 Cl I eaRci\ A-\v_.. Department review required_ Yes No /� \ Buildin Applicant: '�-S C-F)nS1 j i-c-kJn Planning &Zoning Tree Administrator Project: 1 M-k 1,(3 I (L m U t I Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. XWDenied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: /2/2S).201, TREE ADMIN. Second Review: Approved as revised. R(Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: .V. Date: 3l/G/2 a16C-- FIRE SERVICES Third Review: Approved as revised. l6enied. ['Not applicable Comments: Reviewed by: Date: S JZl f ZAP,' 09 sed 05/19/2017 A /f md - /0 -3-2o/i/ �}tl'--Mke.t,u� Building Permit Application lication Atlantic Beach Updated 5/5/17 City of 51 FFICE COPY.Seminole Road, Atlanti Bach, FL 32233 DEC 1 9 2017 -rift 9 Phone: (904) 247-5826 Fax: (904) 247-5845 Job Address:12 I 2 +r1 \'._. Permit Number: gt.,--s ( '" 0341 / Legal Description ib` 1 A61-} I n c I I 12 �l4 S I RE# J ,('jqS -0000 Valuation of Work(Replacement Cost)$ 3e,UOQ Heated/Cooled SF Non-Heated/Cooled • Class of Work(Circle one): New Addition<Iteratio Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): Commercial Residentia • If an existing structure, is a fire sprinkler system installed?(Circle one): Yes 43 N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: -k-"erio Nra. revue -� Florida Product Approval# for multiple products use product approval form Property Owner Information NameK.X t3 HAddress: ?O 600 630 -iLkI6 City {fit\carni c ?Der-VC-Y-1 State FL Zip32233 Phone clog Z4 \ 1\3\ E-Mail Erk0\-N1cU.e..; C7c-'r rc13CAX.C .O Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information Name of Company: P , C • Qualifying Agent: S' � � 5 � I 51 Y g g /���� �� �. >�.,In.�l1 Address /53 7 -� RP/1,j City jp-f, State 9- ( Zip 32 s a Office Phone clefl -may S -qi 0 7 Job Site/Contact Number nn State Certification/Registration# E-Mail tc't(I �(� R )I s�.,tl„ - r Architect Name &Phone# Engineer's Name& Phone# Workers Compensation PrOp Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS, and AIR CONDITIONERS,etc. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER 0: AN ATTORNEY BEFORE RECORD NG YOU N TICE OF COMMENCEMENT. / (Signature of Owner or Agent) 7 ure of'tractor) (including contractor) Signed and sworn to(or affirmed) before me this 1p day of Signed and sworn to(or affir ed) before me this d�y of WoYe.Mbx,2.0n , by_CY\(15 Nk3Y1c1- ttDV ,201 , by �Y\Q— \ --- - - - -� 1 0D -?=)-1Q ����� � BSALCAN (Signature of Notary) , �.,2'o• Notary Public-State of Florida [ . u Commission n FF 229545 Notary Public-State of Florida . My Comm.Expires May 11,2019 ' ( t,• Commission a FF 229545 • — Personally Known OR �[ j Personally Known ORO `c My Comm.Exait@tMay 11,2019 [ I Produced Identification [ ] Produced Identification Type of Identification: Type of Identification: perm, 4-V Res /7_ 07a OFFICE COPY NOTICE OF COMMENCEMENT State o �kr)r't C\Gx. County of )vCL,I Tax Folio No. f7 0/Q5---006 To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property,and in accordance with Section 713 of the Florida Statutes,the following information istate in this N TICE OFC NCEMENT. Legal Description of property being improved: Le- ---tpdAic, LCAS 1,5 1 2 1E' k c i Address of property being improved: i 251 t 3e lacy\ airtit x'1}1 Gni. C ?Deck of) v.k.-11 32-233 General description of improvements: 1 P . t r t p� t(`''e,V' ( -C A.r .v1A• T it h Owner: L' Y1Y t\10Y11 de b Address: P,), ZOx 33011 y8 Wflank►C ev\ Y L 322 Owner's interest in site of the improvement: Fee Simple Titleholder(if other than owner): Name: . Contractor: 5\...4 `YS C Oe --' -A"m. Address: / 15 —fy P.�, .. ,� , Telephone No.: 9 O -_545 - 9 O -i Fax No: Surety(if any) Address: (\I14 Amount of Bond$ Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: Address: Phone No: 4 l 0- Fax No: Name of person within the State of Florida, other than himself, designated by owner upon whom notices or other documents may be served: Name: n Address: V I 0 P Tele hone No: Fax No: In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statues. (Fill in at Owner's option) Name: • Address: A , o Telephone No: • Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER �. Signed. Date: \\- �o• I1 Bef this \o day ofNOvernb ( in the County of Duval,State Doc#2017289772,OR BK 18225 Page 280, , Of Florida,has personally appeared CYl Y i S F'\NVY\i cl-C. Number Pages:1 I Personally Known: q or Recorded 12/19/2017 09:24 AM, ,Produced Identification: ^�� RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL Notary Public: >cj\CCa17 ‘CZ' ClJC >` C $10.00 OUNTY TDING 'My commission expires: 5 - \\-. 20\ C-\ :'i.,"r►'" B SALCAN 0 ' Notary Public-State of Florida 4 V,,,,, c Commission a FF 229545 1 *,:71, 1';;.?`"7 My Comm.Expires May 11,2019 li I r.%" ','' CITY OF ATLANTIC BEACH r' t }' 1 2 2018 800 Seminole Road MAR Atlantic Beach, Florida 32233 REVISION REQUEST / CORRECTIONS TO PLAN REVIEW COMMENTS Date - \2-1' Revision to Issued Permit Corrections to Comments ✓ Permit# RE Cil-o31) Project Address t 1 1 \ a P_ „ , \v.) c\ -\ �• -BCC,, 2 -i 3 ni Contractor/Contact Name S� (f S \54, 'T nL . i)v-N P i-e I 6-, S o. , Phone 59'5 '61' Email . - ,i► . 11.1 ' y Description of Proposed Revision/Corrections: Permit Fee Due $ —0 (.‘"L'rei1_ IV Niu._\-- eii,,,3-6 Additional Increase in Building Value $ (.D Additional S.F. By signin below,I ire I( 6-,S ft, %---}-1-, affirm the Revision is inclusive of the proposed changes. (printed name) Si attire of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review Comments/11TS$its el. Vad i 5' 0 f pdr cA 6 SpA , ,r -Air ma, kw". Department Review Required: M Building i' ' ` - -: : oning Reviewed By Tree Administrator Public Works 3116120/2 0 Public Utilities Public Safety Date Fire Services . , ____.i . 1...,.\.,v--;.„ 'ri /,, �f I'I AVN 1 y!1 CITY OF ATLANTIC BEACH 4 800 Seminole Road ; J.' aj rr? Atlantic Beach,Florida 32233 N-. tl A fri Fi © -1:1 (L I REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Dates-I, ---t g Revision to Issued Permit Corrections to Comments_ Permit# (1,t S II 03t Project Address I a l l ()_,0,_a. v--e_ Contractor/Contact Name S- --ti tes Corr\ST. Phone S.tr,S.-- ct I Q` \ EmailCNCr`< tk Lk t3\ ZPt(SOu sr-e7-\ Description of Proposed Revision/Corrections: Permit Fee ue $ 5V. Do _______ —___,) kti/t CA-9-. ) ? Pc rA_S --t)Additional Increase in Building Value $ Additional S.F. By signing below,I J Ober,I L.L INN., affirm the Revision is inclusive of the proposed changes. (print$y„.‘:,-;11/\. name) / p Sig .ture a Contractor/• gent t ontractor must sign if increase in valuation) Date (Office Use Only) Approved Denied )(-- Not Applicable to Department Revision/Plan Review Comments /T '/ SS ,N, PQ5&- 30 V Department Review Required: Bt,--14;:--lin / , i Planning & Zoning Reviewed By Tree Administrator Public Works Public Utilities S/2 6/2o/ 2--- Public Public Safety Date Fire Services p4r' f� 6° ' '' �S\ CITY OF ATLANTIC BEACH f 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 (904) 247-5800 \0.219 f. BUILDING REVIEW COMMENTS Date: 3/16/2018 _ Permit#: RES17-0311 Site Address: 129199 BEACH AVE Review Status: DENIED RE#: 170295 0000 Applicant: STYLES CONSTRUCTION, INC. Property Owner: HIONIDES CHRIS Email: DARRELL4131@BELLSOUTH.NET Email: Phone: 9045459107 Phone: 9045459107 THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: 1. Just a reminder to check out the porch on the back of 1291 Beach Ave, is there an existing roof and walls? 2. Energy calcs shows the attic is unvented. Is this an existing condition or are you planning on spray foaming. If the attic is to be foamed then I will need the ICC-ES reports on what type of foam is to be used. Building Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233 904.247.5844 Email:mjones@coab.us env; Lei R.01,n "r0 Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with "clouding".The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud. The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which t. ;� ".P.,:!r, CITY OF ATLANTIC BEACH '" -. .. , 800 Seminole Road -' A s Atlantic Beach,Florida 32233 J ".;,aim:s-i: -'' REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date 1- /S-18 Revision to Issued Permit Corrections to Comments Permit# F611.-/- 031 I Project Address 2-9 \ l f J`P,a— Contractor/Contact Name s- 1,S CorNsi_ T l'\C'. DA(r t l . Stv‘%4 K Email II� � - 4 Phone 9 Dq 59c�' �up-i E ������ ��l Description of Proposed Revision/Corrections: Permit Fee b ue $ / S• 0 r e1tvr - o, 4_ sur,..c..,,e Additional Increase in Building Value�$ Additional S.F. By signing below,I DAc'i'e..t` (T-'S YA A affirm the Revision is inclusive of the proposed changes. (printed name) ,,Z./ //AI-. ., ... q- ) 3- l8 Sig "ie o Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review Comments Department Review Required: :uildinq- -nnia : a - Reviewed By ree £•mintstrdtt r r7. Public Works Public Utilities Public Safety Date Fire Services S '�,1'-.:.; CITY OF ATLANTIC BEACH r N 800 Seminole Road is? __ _:EAtlantic Beach,Florida 32233 REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date -I S`"I g Revision to Issued PermitCorrections to Comments / rmjt# R Fs,3-o31 J Project Address l 29 \ t S U >e Contractor/Contact Name..- a _ t IILki-' Phone 9bL1 ` 59S' -1101 Email Done.\\Lik3` Ct ieIl‘spJ�\ - 4 Description of Proposed Revision/Corrections: Permit Fee Due$ et tv 1 o,. a- S v r...c.v Additional Increase in Building Value'�$ Additional S.F. By signing below,I DA,C {-e,.` l S-(pv i affirm the Revision is inclusive of the proposed changes. (printed name) ��7 - q- ) 3- )8 Sig :1 . e o Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department 7 Revision/Plan Review Comments Department Review Required: ildino'1, 1 •• •• •• - Reviewed By -- •. . • Public Works G , 2 v 1 6 Public Utilities I Public Safety Date Fire Services J , CITY OF ATLANTIC BEACH 1J 800 SEMINOLE ROAD '" ATLANTIC BEACH, FL 32233 7:4" (904) 247-5800 9131 r BUILDING REVIEW COMMENTS Date: 5/26/2018 Permit#: RES17-0311 Site Address: 129199 BEACH AVE Review Status: denied RE#: 170295 0000 Applicant: STYLES CONSTRUCTION, INC. Property Owner: HIONIDES CHRIS Email: DARRELL4131@BELLSOUTH.NET Email: Phone: 9045459107 Phone: 9045459107 THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: i. Did not receive Page A304, ELEVATIONS AND DETAILS, as noted on page A300 in the SHEET LIST. Provide 2 copies. 2. Clouded area at front porch, page A302, shows 4 horizontal lines, that is 4 vertical elevations changes, or 4 risers which would require handrails on at least on side of the stair system. FBC-Residential 2017 6th Edition, R311.7.8. Verify and confirm that this situation will or will not exist on the new porch. Building Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233 904.247.5844 Email:mjones@coab.us Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with "clouding".The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud.The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on whict a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with A zoN,A., • CITY OF ATLANTIC BEACH BUILDING SERVICES BUILDING INSPECTOR/PLAN REVIEW COMMENTS PROJECT: 1291 Beach Ave Garage Apartment PERMIT NUMBER: 170295-0000 Project Address: 1291 Beach Ave, Atlantic Beach Florida 32233 January 22, 2018 Architect's Responses to Hionidis Garage Apartment Review Comments (Responses in Italics) Initial Building: Mike Jones 1. Comments: The energy calculation forms show that the attic will be unvented. Is this an existing condition?If not and the attic is to be insulated with spray foam please submit the ICC-ES information sheets on the type of spray foam to be used. 2 copies. Response: This is an existing condition. / 2. Comments: Fill out completely the EPL Display Card in the energy forms. / Response: We understand, Contractor will provide. llV// 3. Comments:A second complete set of energy calculation forms is required,all / completely filled out. VVV Response: We understand, Contractor will provide. 4. Comments: A second copy of the Florida Product Approval Information Forms is t7 needed. Response: We understand, Contractor will provide. 5. Comments: Finish filling out the last page of the product approval information sheet. 1 Response: We understand, Contractor will provide. 6. Comments: Product approval numbers that end with an'R'value are not acceptable.Contact window/door supplier and get the exact number for the door/window to be installed.For example,the Pella Double Door with the FL#14892-R3 has 21 different doors listed under that number.The department needs that exact number,down to the decimal point,if needed. Response: We understand, Contractor will provide adjustments. 7. Comments: Submit 2 legal surveys.Showing the existing porches and their horizontal protrusions from the house outward. Response: We understand and will provide the surveys. A • 't 1 ST A.'ay . Comments: Submit 2 copies of elevations of the proposed new porches. Showing the height of the walking surface above the grade below. Provide handrails and guard i. details where applicable. R311.7.8, R312.1.1. Response: We have updated the plans to show the porch elevations. The rear platforms are only 12"above grade and do not require handrails and the front porc has steps that go all the way across, thus negating the need for handy. • 9. Comments: FYI.Bathroom#2 has glazing in a hazardous location. Provide / tempered glass for that window.It is now noted on the plans. �/ Response: That is an existing window that is a 26x3°window which doesn't not meet the 9 sqft requirement. .01110,400,0 a�_ sponses respe��> a submitted by: • ,. co(ts•1 )ki ' . .r 1 .JohnitraVIII .• •- O •chitect of g 4164;p. RED N`-as. ;iiiii 2600 Belfort Road,Jacksonville,Florida 32216 904.371.2790 john@zona-associates.com AR 9089 9. FYI. Bathroom #2 has glazing in a hazardous location. Provide tempered glass for that window. It is now noted on the plans. Mike Jones Building Inspector/Plan Reviewer City Of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233-5445 Ofc (904) 247-5844 Fax (904) 247-5845 mai �lovrY w Co lid vr•-n f r 12-2? - 17 /7‘1?)' 2 t a OFFICE COPY PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA Project Name: 44 j a A j i S 's +GSd ► Permit #AES/7"O 3J/ Project Address: 1 ZS( ` Be Ack Rue 141, ( 32-2-13 As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide .roduct approval may be obtained at:www.floridabuildine.or . Category/Subcategory , Manufacturer • Product Description l Limitation of Use State# Local# A. EXTERIOR DOORS 1. Swinging 1e D6061t Doo 2. Sliding P-e W- Vi►iv ‘,Aal.taouJ i41oC 3. Sectional 4. Roll up 5. Automatic 6 herI.{ rt_vt9f, 11 w► Swiktl It) d o a v2 , �o B. WINDOWS 1. Single hung 2. Horizontal slider 3. Casement 4.Double hung 5. Fixed Pe t'i4. V�•ot�Iv tAoi A.h.... 1 403 6. Awning 7. Pass-through 8. Projected 9.Mullion 10. Wind breaker 11.Dual action 12. Other Category/Subcategory Manufacturer Product Description 'Limitation of Use State# Local# C. PANEL WALL 1. Siding r , 2. Soffits 3.EIFS 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8.Membrane 9. Greenhouse 10. Synthetic stucco 11. Other D. ROOFING PRODUCTS 1.Asphalt shingles 2.Underlayments 3. Roofing fasteners 4.Nonstructural metal roof 5.Built-up roofing 6. Modified bitumen 7. Single ply roofing 8.Roofing tiles 9. Roofing insulation 10. Waterproofing 11. Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coats 15. Roof tile adhesive 16. Spray applied polyurethane roof .F � I i i I I I 17. Other Category/Subcategory Manufacturer Product Description Limitation of Use P i State# Local# E. SHUTTERS 1.Accordion 2.Bahama 3. Storm panels 4. Colonial 5. Roll-up 6. Equipment 7. Other F. STRUCTURAL COMPONENTS 1. Wood connector/anchor 2. Truss plates 3. Engineered lumber 4. Railing 5. Coolers-freezers 6. Concrete admixtures 7. Material 8. Insulation forms 9.Plastics 10.Deck-roof 11. Wall 12. Sheds 13. Other G. SKYLIGHTS 1. Skylight 1r 1 1 2. Other Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# l H. NEW EXTERIOR J ENVELOPE PRODUCTS 1. 2. In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. (Contractor Name) (Print Name) (S),gnature) Company Name: c r' ay,15 71r T1 ;:; �- __- -....,_.._.. Mailing ddress: . , > 7 - - >/ iVl4I / if) 71 City: /t.1. I,c 4, State: '7--I/ Zip Code: �j2�s'0 Telephone Number: goy) 5 7s— --q/a 7 Fax Number: ( ) Cell Phone Number: ( ) E-mail Address: j / R E LC- C/t. / et'llSa(.1 Tlt -4,U/ , OFFICE COPY FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Hionidis Garage Remodel Street: i/--i,\ 7 Beach Ave Builder Name: Permit City,State.Zip: Atlantic Beach.FL. Number: Office: Atlantic Beach Permit Owner: Jurisdiction: 261100 Design Location: FL,MAYPORT NS County:: Duval(Florida Climate Zone 2) 1. New construction or existln ' g New(From Plans) 9. Wall Types(2823.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood.Exterior R=19.0 2011.40 ft2 b.Concrete Block-Int Insul,Exterior R=5.0 543.48 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=13,0 268.80 ft2 4. Number of Bedrooms 3 d.N/A R= ft'- 5. Is this.a worst case? No 10.Ceiling Types (1160.0 sqft.)- Insulation Area a.Roof Deck(Unvented) c R=30.0 1160.00 ft2 6. Condtioned floor area above grade(ft2) 1622" b.N/A R= ft2 Cond'.tioned floor area below grade(ft2) 0 c.N/A R= ft2 7. Windows(468.9 sqft.) Description Area 11.Ducts R ft2 a.Sup:1st Floor.Ret:1st Floor,AH:Garage 6 210.86 a. U-Factor: Dbl,U=0.40 ,' 468.90 ft2 SHGC: SHGC=0.25 b. U-Factor. N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 33.8 SEER:14.50 c. U-Factor: N/A ft2 SF-GC: d. U-Factor: N/A 13.Heating systems kBtu/hr Efficiency ft2 a.Electric Heat Pump 33.8 HSPF:8.20 Area Weighted Average Overhang Depth: 3.150 ft. Area Weighted Average SHGC: 0.250 14.Hot water systems 8. Floor Types (1622.0 sqft.) Insulation Area a.Propane Tankless Cap: 1 gallons a.Floor over Garage R=13.0 658.00 l2 EF:0.750 b.Slab-On-Grade Edge Insulation b. Conservation features R=0.0 502.00 ft2 None c.other(see details) R= 462.00 ft2 15.Credits Pstat • Total Proposed Modified Loads: 60.44 Glass/Floor Area: 0.289 PASS Total Baseline Loads: 63.27 f�i I hereby certify that the plans and specifications covered by """"'' , this calculation are in compliance with the Florida Ener Review of the plans and . , �I-lc SI;;i :u� Code. 9Y specifications covered by this e. •.Hys`` 1_ G��V IS calculation indicates compliance 0. . y Ryan B. Florida , ` SIA, -r Ellis with theorida Energy Code. .. =.J. • ;,,.,,s,.. ',: , PREPARED BY: _.. s 1 4 DATE: 12/5/17 Before construction is completed cc 4 this building will be inspected for 5's '' 1 compliance with Section 553.908 , '77"- --"(".•=- ----- I hereby certify that this building,as designed, is in compliance Florida Statutes. ' 6:= `•r with the Florida Energy C 'Z-',A;,',7,..„,„---v a OWNERIAGENT:-__ �) '''' 1,:z...-, •-�~ DATE: �6_f d �� BUILDING OFFICIAL: _ - - DATE: - ,L a/`'" - - - ompliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with 8403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1,2017 this prcject requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50(R402.4.1.2). 12/5/2017 10:43 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 1 of 5 FORM _--- — PROJECT -- , — -- _____.4 Title: Hionidis Garage Remodel Bedrooms: 3 Buildirg Type: User Address Type: —Street Address Conditioned Area: 1622 Owner: Lot= Total Stories: 2 Block/SubDivision: #of Units: 1 Vvorst Case: No Builder Name: PlatBook: Rotate Angle: o Street-Permit Office: Atlantic Beach Cross Ventilation: 1 u a Beach Ave Jurisdiction: 261100 County: Duval Jurisdiction: Whole House Fan: City,State.Zip:p: Atlantic Beach. Family Type: Single-family New/Existing: New(From Plans) FL. Comment t CLIMATE !ECG Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone87.5 9'0 2.5% Winter Summer Degree Days Moisture Range FL,MAYPORT NS FL MAYPORT NS h2 39 90 70 75 1037 61 Medium BLOCKS Number Name Area Volume L- 1 Biockl 1622 19672.8 SPACES ® r Number Name .--_-_ o d 1Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled ;Heate Area d 1st Floor 502 4216.8 No --- 1 .---- ---- ----------- -- _ 1 1 Yes Yes 1'25 2 2nd Floor 1120 15456 Yes 3 2 .. 1 Yes Yes a FLOORS -- " # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet _ 1 Slab-On-Grade Edae Insulation 1st Floor 96.7 ft 0 502 ft2 t --- 0 0 1 [ 2 Floor over Garage 2nd Floor --- -- 658 ft2 13 0 0 1 ____ 3 Floor Over Other Space 2nd Floor -- 462 ft= 0 0 p 1 ROOF - _ Roof Gable Roof Solar �" SA Emitt Emitt Deck P tch i. Type Materials Area Area Color Absor. Tested - — Tested tnsul (deg) Gable or shed Composition shingles 1640 ft= 580 ft' Medium 0.611 No 0.4 No 30 1.15 ATTIC # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full cathedral ceiling Unvented 0 1160 ft2 N N 12/5/2017 10:43 Afv1 EnergyGaugeO USA-v5.1-Section R405.4.i Compliant Software Page 2 Of.; FORM R405-2014 CEILING - V� _ Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) 1st Floor 0 Blown 40 ft= 0.11 .---. 2 Under Attic(Unvented) 2nd Floor p Wood Blown 1120 n= 0.11 Wood _ _ . WALLS Adjacent y Width Height Sheathing Framing Solar Elelow �/= r°L--- Ta all-T}pe Space Cavity 9 1 E Exterior Concrete Block-Int Insul 1st Floor P- ue_-Ft-ln E. lrt_.___,a,raa R=ValJR Eraction-Absor.-G.ade°tia 5 18.3 8.4 153.7 ft2 0 0.170000 0 2 N Exterior Concrete Block-Int Insul 1st Floor 5 30 ---- 3 W Exterior Concrete Block-Int Insul 1st Floor 5 8 4 252 0 ft2 0 0.170000 0 16.4 8.4 137.8 ft= 0 0.170000 0 4 S Garage Frame-Wood 1st Floor 13 30 8.4 252.0 ft2 0.05 0.170000 0 5 W Garage Frame-Wood 1st Floor 13 2 8.4 16.8 ft2 0.05 0.170000 0 6 E Exterior Frame-Wood 2nd Floor 19 20 4 80.0 ft2 ---_ 7 S Exterior Frame-Wood 0.05 0.170000 0 2nd Floor 19 4 15.4 61.6 ft2 --._ 8 E Exterior Frame-Wood 0-05 0.170000 0 2nd Floor 19 17.6 15.4 271.0 ft2 -.- 9 N Exterior Frame-Wood 0.05 0.170000 0 2nd Floor 19 4 15.4 61.6 ft2 10 N Exterior Frame-Wood 0.05 0.170000 0 2nd Floor 19 26 22.1 574.6 ft2 11 WExterior Frame-Wood 0.05 0.170000 0 2nd Floor 19 20 4 80.0 ft2 -12 W Exterior Frame-Wood 0.05 0.170000 0 2nd Floor 19 20 15.4 308.0 ft2 13 S Exterior Frame-Wood 2nd Floor 19 26 0.05 0.170000 0 22.1 574.6 ft2 0.05 0.170000 0 WINDOWS Orientation shown is the entered,Proposed orientation. Wall # Ornt ID Frame Panes Overha1ng _ NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 1 Vinyl Low-E Double Yes 0.4 0.25 10.5 ft2 10 ft 0 in 3 ft 0 in None Nine 2 N 2 Vinyl Low-E Double Yes 0.4 0.25 54.0 ft= 6 ft 0 in 3 ft 0 in 3 N 2 Vinyl Low-E Double None None Yes 0.4 0.25 51.6 ft2 6 ft 0 in 3 ft 0 in 4 E 8 Vinyl Low-E Double None None Yes 0.4 0.25 42.2 ft= 1 ft 4 in 7.2 ft 0 in 5 E 8 Vinyl Loev-E Double None None Yes 0.4 0.25 20.1 ft= 1 ft 4 in 5.2 ft 0 in 6 N 10 Vinyl Low-E Double None None Yes 0.4 0.25 27.0 ft2 1 ft 4 in 12 ft 0 in 7 N 10 Vinyl Low-E Double None None Yes 0.4 0.25 60.3 ft= 1 ft 4 in 12 ft 0 in None 8 W 12 Vinyl Low-E Double Nave Yes 0.4 0.25 25.0 ft= 1 ft 4 in 5 ft 0 in � W 12 Vinyl Low-E Double None Ncre 109 S 13 Vinyl Low-E Double Yes 0.4 0.25 12.0 ft2 1 ft 4 in 6.3 ft 0 in None Ncre Yes 0.4 0.25 60.0 ft2 1ft4in 14ft0in 11 S 13 Vinyl Low-E Double Yes 0.4 0.95 ft2 None None 27.0 1 ft4in 7.3ft0in None None 12 E 8 Vinyl Low-E Double Yes 0.4 0.25 12.0 ft= 1 ft 4 in 3 ft 0 in None 13 E 1 Vinyl Low-E Double Yes None 14 0.4 0.25 20.1 ft= 10 ft 0 in 3 ft 0 in None Noce N 2 Vinyl Low-E Double Yes 15 N 10 Vinyl Low-E Double Yes 0.4 0.25 20.1 ft= 6 ft 0 in 3 ft 0 in None Non: 0.4 0.25 27.0 ft= 1 ft 4 in 7.3 ft 0 in None Non?. 12/5/2017 10:43 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 3 of E. • FORM R405-2014 GARAGE # Floorq� Ceiling Area Exposed Wall Perimeter Expoed Wall Insulation Avg.Wall Height s 1 698 ft2 _Ceiling 698 ft2— - -- — _ 75.6 ft 8.4 ft 1 INFILTRATION Scope Method SLA CFM 50 ELA '--- EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) 000539 2295.2 �I 126 236.96 .5114 7 HEATING SYSTEM VT System Type -__ Subtype-------------yP E�!cienc:� Capacity --- Block Ducts 1 Electric Heat Pump None HSPF:8.2 33.8 kBtu/hr 1 Sy:n''#1 COOLING SYSTEM System Type _ Fyp Subtype Efficiency Capacity Air Flow SHR Block Cuts 1 Central Unit None — — • SEER:14-5 33.8 kBtu/hr 1014 cfm 0.75 1 s rs:1 HOT WATER SYSTRE: `.� # System Type SubType Location EF P SetPnt Ca Use Conservation 1 Propane Tankless Exterior - — ---- - 0.75 1 gal 60 pal 120 deg None P SOLAR HOT WATER SYSTEM �I' FSEC — — _ a Cert# Company Name Collector Storage System Model;= Collector Model A Area Volume FEF li None None — ft2 u fl m DUCTS ;, V - ---Supply— —Retum— Air CFM 25 CFfv125 i A Location R-Value Area Location Area Leakage Type HandlerHt rfu� TOT OUT QN RLF Heat Cool 1 1st Floor 6 _ _ 10.86 f 1st Floor 81.1 ft2 Default Leakage Garage (Default)c(Default)c --- . 1 1 12i5/2017 10:43 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cootinc „xi Ven lino 1.x] Jan Feb Mar Aprr [ ]May X Jun f X Jul X Aug Se Jan Feb .X]Mar pll 1!Ma� t Jul Aug X�Sep Oct Nov Dec _ _ AprMay Jun Jul Aug 1 SeP JX Oct Nov X Dec Thermostat Schedule: HERS 2006 Reference ( Dec Schedule Type Hours — -- 1 2 3 4 5 6 7 8 Cooling(WD) 9 10 11 12 AM 78 78 78 78 78 PM 80 80 78 78 78 78 78 78 78 78 78 80 80 Cooling(WEH) 78 AM 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 6678 PM 66 68 68 66 66 68 6688 6688 68 68 68 68 68 68 68 38 Heating(WEH) AM 66 66 B6 38 PM 68 68 68 68 6866 66 68 68 68 68 68 68 68 lib 68 68 68 68 66 136 12/5/2017 10:43 AM EnerayGauge®USA-vS.1-Section R405_4.1 Compliant Software Page 5 of'5 FORA/ R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPertormance Index, the more efficient the home. 1147 Beach Ave; Atlantic Beach, FL. ------- 1. New construction or existing New(From Plans) 9. Wall Types Insulation a.Frame-Wood.Exterior Area Single family or multiple family Single-family 3. Number of units,if multiple family 1 2. b.Concrete Block-Int fnsul,Exterior R=5 00 2011.40 ft2 c. Frame-Wood,Adjacent 568.•0 ft -1. Number of Bedrooms 3 d.N/A R=13.0 268.80 ft= 5. Is this,a worst case? R= ft2 No 10.Ceiling Types Insulation Area a.Roof Deck(Unvented)Conditioned floor area(ft') 1622 R=30.0 1160.00 ft= b.N/A R= ft= 7. Windows- Description Area c.N/A a. U actor. R= ft= Dbl,U=0.40 468.90 ft2 11.Ducts R ft2 a.Sup:1st Floor,Ret:1st Floor,AH:Garage 6 210.86 SHGC: SHGC=0.25 b. U----"actor: N/A ft2 SI-GC: c. U-Factor. N/A 12.Cooling systems kBtu/hr Efficiency SI-GC: ft2 a.Central Unit 33.8 SEER:14.50 d. U-Factor. N/A _ SI-GC: ft 13.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.150 ft a.Electric Heat Pump Area Weighted Average SHGC: 33.8 HSPF:8.20 0.250 8. Floor Types Insulation Area 14.Hot water systems a.Floor over Garage R=13.0 658.00 ft= a.Propane Cap:1 gallons b.Slab-On-Grade Edge Insulation R=0.0 502.00 ft= c.other(see details) EF:0.75 = 462.00 t= b. Conservation features R None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building - -z-:--.. Construction through the above energy saving features which will be installed(or exceeded) `;'6 VEsr Tom. in this home before final inspection. Otherwise, a new EPL Display Card will be completed w~ � - ,``. based on installed Code compliant features. ✓ . O Builder Signature: � r' / 1 vs�_i+x if_'•=i_._,y / t Date: W 4 ';� c•• Address of New Home: (-66.,_ __Lat_".,_ i ''� 2 1 Ci /FL �' _SOD 1ti'E'1 %v 'Nolte: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-•1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 12/5/2017 10:43 AM EnergyGauge®USA-v5.1- Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations ADDRESS: Residential Whole Building Performance and Prescriptive Methods 1147 Beach e Atlantic Beach,FL. Permit Number: MANDATORY REQUIREMENTS See individual code sections for full details. X 401.3 Energy Performance Level(EPL)display card Mandato ry). The ing officialcat be completed and certified by the builder to be accurate and correct before'final approval ofIl th the for occup ncy.Florida law[Section 553 splayrequire tt an energy erformance level(EPL) 085, Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonst-ate co npliance for the building.A copy of the EPL display card can be found in Appendix C. X 84.02.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections 8402.1 Air R402.4.4. X R402.4,1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official.an approved third party shall inspect a0 components and verify compliance. ▪ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2.and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7). Fbrida Statutes or individulas licensed as set forth in Section 489.105(3)(f),(9),or(i)or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures: 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be tumed off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. X R402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. X R402.4.3 Fenestration air leakageWindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. X R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. X R403.1.1 Thermostat provision(Mandatory).At least one thermostat shall be provided for each separate heating and cooling system. X R403.1.3 Heat pump supplementary heat(Mandatory)Heat pumps having supplementary electric-resistance heat shall have controls that. except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. X R403.2.2 Sealing(Mandatoryihll ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either individuals as defined in Section 553.993(5)or(7).Florida Statutes.or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i),Florida Statutes•to be"substantially leak free"by either of the following: 1. Post-construction test Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area wher tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All registe-boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm(85 Umin;per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the budding envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 12/5/2017 10:43 AM EnergyGauge®USA-v5.1- Section R405.4.1 Compliant Software Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) R'.03.2.3 Building Cavities(Mandatory), Building framing cavities shall not be used as ducts or plenums. ' R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41'C)o- below 55°F(13`C)shall be insulated to a minimum of R R403.3.1 Protection of piping insulation. 0 R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. R403.4.3 Heat traps(Mandatory). Storage water mraos installed on both the inlets and outlets.Eternal heat rtraps shall s not equipconnsi ft of e tthhherla c mmc cihaving ally available heatlpipe risers shall have heat trap or a downward and upward bend of at least 3'4 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. v f� R403.4.4 Water heater efficiencies(Mandatory). X R403.4.4.1 Storage water heater temperature controls R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140'F(38'C to 60°C). 8403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of combustion types of service water heating systems to be turned off. R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Tab e X C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the pe of equipment used to provide heating functions as par of a combination system shall satisfy all stated requirements for he appropriate waterinstalled. clat entry., Solar water heaters shall met the criteria Section R403.4.4.2.1. 9 9 R403.4.4.2.1 Solar water heating systems.Solar systems for domestic hot water production are rated by the annual solar energy fa:ior of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors.and SRCC Stange rd TM-1.Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meeet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. 0 R403.5 Mechanical ventilation(Mandator/). The building shall be provided with ventilation that meets the requirements of the Florida 3u Iding Code.Residential or Florida Building Code.Mechanical,as applicable,or with other approved means of ventilation.Outdoor air ntaikes and exhausts shall have automatic or Gravity dampers that close when the ventilation system is not operating. of R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. �r ti R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies.based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section 8302.1. This code does not allow designer safety factors.provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems_ • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6.or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shell not be less than the calculated latent load. 12/5/2017 10:43 AM EneroyGauge®USA-v5.1- -Section R405 4 1 Compliant Software Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) tr et R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shelf be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data,the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load catculati Dr, and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer.in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. 4^ =� R403.6.1.2 Heating equipment capacity R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R4C3.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. ° R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. -•r `t R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an r aermittent basis.such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2 A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.6 Snow melt system controls(Mandatory). Snow and ice-melting systems.supplied through energy ser/ice to the building.shall include automatic controls capable of shutting off the system when the pavement temperature is above 55`F,and no precipitation is falling ann ar automatic or manual control that will allow shutoff when the outdoor temperature is above 40'F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160.Table 2.Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a peeset schedule shall be installed on all heaters and pumps.Heaters.pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at they water surface ora liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools denying over 70 percent of the energy for heating from site-recovered energy.such as a heat pump or solar energy source computed over an operating season. RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be "rig'i-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. 0 8404.1.1 Lighting equipment(Mandatory). Fuel pas lighting systems shall not have continuously burning pilot lights R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. X R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space.R-10 is allowed. 12/5/2017 10:43 AM EnergyGauge®USA-v5.1 - -Section R405.4.1 Compliant Software Page 3 of 3 • FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Hionidis Garage Remodel Slreet: 1147 Beach Ave Builder Name: City,State,Zip: Atlantic Beach,FL, Permit Office: Atlantic Beach Ormer. Permit Number. Design Location: FL,M1AYPORT NS Jurisdiction: 261100 COMPONENT CRITERIA Air barrier and thermal barrier A continuous air barrier shall I CHECK be Installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in X substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and X Rirrl oists -� Rim joists are insulated and include an air barrier. X Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. X Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawispace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I X Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. X Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled l H by insulation that on installation readily conforms to the available cavity X spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. X Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight. IC rated,and sealed to the drywall. X Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to X available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. X Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. X HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. X Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 12/5/2017 10:43 AM EnergyGauge®USA-v5.1-Section R405.4.1 Compliant Software Page 1 of 1 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method ..] Project Name: Hionidis Garage Remodel Street 1147 Beach Ave Builder Name: City,State.Zip: Atlantic Beach,FL, Permit Office: Atlantic Beach Desigr Location: FL,lv1AYPORTNS Permit Number. Cond.Floor Area:: 1622 sq.ft. Jurisdiction: 261100 Cond.Volume: 19673 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: __ — n: CFM(50): — - _ R: Single or Multi Point Test Data _ ELA: _ ------- HOUSE PRESSURE ! FLOW: EgLA: 1 -- - Pa-- ! cfm • ACH: 2 Pa r — cfm SLA: 3— Pa i — — cfm 4 • Pa i cfm ACH(50)* : 5 P– = For prescriptive projects, tested leakage must be -- _—__ , cfm ' <=7 ACH(50). For performance projects,tested 6 -- Pa ! cfm leakage must be<=the ACH(50)shown on Form R405-2014 for this project. 8402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate.Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w-g.(50 Pascals).Testing shall be conducted by either individi als as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105 3 f party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed si any time after creation of all penetrations of the building thermal envelope. ( )() (g).or(i)or an approved third During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed.beyond the intended weatherstripping or other infiltration control measures: 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures: 3.Interior doors,if installed at the time of the test,shall be open: 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed: 5.Heating and cooling systems,if installed at the time of the test,shall be tumed off:and 6.Supply and retum registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Testing shall be conducted by either performance results demonstrate compliance fHE sr ' individuals as defined in Section . 'p1 T with Florida Energy Code requirements in 553.993(5)or(7), Florida Statutes or =. '�` ' Y: individuals licensed as set forth in �`'�' accordance with Section 8402.4.1-2. = 489.105 /. .,.::, Section (3)(f), (g), or(i)or an p. _ , .7, __ ; approved third party. A written report lP r w a SIGNATURE: of the results of the test shall be " ' , signed bythe third a � 1.—--"e . , g r; _ - party conducting :�f �:>� �� PRINTED NAME: ``'I` '� ,7. ---.V.,',1/ the test and provided to the code ti4 DATE: _ BUILDING OFFICIAL: -- DATE: - 12.7-S-11 12/5/2017 10:43 AM EnergyGauge®USA-v5.1 -Section R405.4.1 Compliant Software Page 1 of 1 - �J?� y�� so Manual S Compliance Report Job: Entire House Date: 11/24/17 By: M.Ellis Energy Design Systems, Inc. 11727 Brady Rd.Jacksonville.FL 32223 Phone:904-268-3670 Fax:904-268-3670 Email:eds.jax@o gmail.com 1111111111111 MINIM --,,:44;41.1., ,,,,,„,,,4d•n ,',yt-,,,,•,-;.„-i”' .%.,•:...n4;5-' ,.--x' .. .. t.a :..v r i.t. -.raa q t' a t '.. 1,t ..7 tom* 'S +' 04T i a i s w - � 'r :•°.".1:.:-"--:' .. . �,F�,r.,�a...a:�.ti4.z+l�'e�atsl�`` For: Hionidis Garage Remodel 1147 Beach Ave.Atlantic Beach. FL Design Conditions Outdoor design DB: 94.4°F Sensible gain: 26441 Btuh Outdoor design WB: 77.4°F Latent gain: 3845 Btuh Entering coil DB: 62.0'F Indoor design DB: 75.0°F Total gain: 30286 Btuh Entering coil WB: 62.5'F Indoor RH: 50% Estimated airflow: 1127 cfm Manufacturer's Performance Data atActual Design Conditions Ecuipment type: Split ASHP Manufacturer: Comfortmaker Model: NXH536GKA**+FVM4X36***L Actual airflow: 1127 cfm SEnsible capacity: 26364 Btuh 100% of load Latent capacity: 7436 Btuh 193%of load Total capacity: 33800 Btuh 112% of load SHR: 78% Design Condition ..a. " OLtdoor design DB: 38.1°F Heat loss: 24171 Btuh Entering coil DB: 68.0°F Incoor design DB: 68.0°F Manufacturer's Performance Data atActual Design Conditions Equipment type: Split ASHP Manufacturer. Comfortmaker Model: NXH536GKA**+FVM4X36*''*L Actual airflow: 1127 cfm Output capacity: 33800 Btuh 140%of load Supplemental heat required: 0 Btuh Capacity balance: 30 °F Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1127 cfm Output capacity: 10.7 kW 152% of load Temp. rise: 99 °F Meets are all requirements of ACCA Manual S. - 11-1 w'rightSof Right-Suite-Universal 2017 17.0 17 RSU17457 2017-Dec-05 10:43:24 AC ...dis Garage Remodel. 1147 Beach Ave.All Bch.rup Calc=MJ8 Building Front faces: S Pape +1+ wricthtsof Project Summary Date Entire House Date: 11/24/17 Energy Design Systems, inc. By: Ellis 11727 Brady Rd.Jacksonville,FL 32223 Phone:904-268-3570 Fax:904-258-3670 Email:ads.Jax@gmail.com y IY a ;". .0-•# _ �_ .3sh.X a i '�..,.,rA .��C='•QQ Y 6) SO.... -r4 / 4.4 l 1 6 }.y For. Hionidis Garage Remodel 1147 Beach Ave.Atlantic Beach. FL Notes: — _- a ' ;u t0 9 Weather. Mayport Ns, FL, US Winter Design Conditions Summer Design Conditions Outside db 38 °F F Inside db 68 °F Outside db , Design TD 30 °F Inside db 7954 °F Design TD 19 °F Daily range L Relative humidity 50 % Moisture difference 50 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 24171 Btuh Ductsccture 26441 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh 0 Btuh (none) Central vent (0 cfm) 0 Btuh Humidification 0 Btuh (none) Piping 0 Btuh Blower 0 Btuh Equipment load 24171 Btuh Use manufacturers data Infiltration Rate/swing multiplier 1..000. Equipment sensible load. „.26441-)Btuh Method Simplified Avera d Latent Cooling Equipment Load Sizing Construction quality A Fireplaces g 1 (Average) Structure 3845 Btuh Ducts 0 Btuh HeatingCooling Central vent(0 cfm) 0 Btuh Area(ftz) 16221622 (none) Volume(ft') 21465 E uipment latent load :;:x$45-8tuh Air changes/hour 21465 Air AVF (cfm) 0.44 0.20 E ui ment total load 156 72eq. o capaci y a .74 SHR C:302816--Btuh ton ~-''�3.0 ton Heating Equipment Summary Cooling Equipment Summary MTrade COMFORTMAKER r Make Comfortmaker Model NXH536GKA** Trade COMFORTMAKER AHRI ref 9636063 Cond NXH536GKA** Coil FVM4X36***L Efficiency 8.2 HSPF AHRI ref 9636063 Heating input Efficiency 12.0 EER, 14.5 SEER Heating output 33800 Btuh @ 47°F LSatent))coolinge ng 2366010140 Btuh Temperature rise 27 °F8Btuh Actual air flow Total cooling 33800 Btuh Airc flow factor 1127 cfm Actual air flow 0.047 cfm/Btuh Air flow factor 1127 cfm Static pressure 0 in H2O 0.043 inH2 cfm/Btuh Space thermostat Static pressure0 in H2O Capacity balance point= 30 °F Load sensible heat ratio 0.87 Backup: Input= 11 kW, Output= 36627 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. –..... hteb i _I vr!rig-----Ft RightSuile0 Universal 2017 17.0.17 RSU17457 ` '' _alis Garage Remodel,1147 Beach Ave.All Bch.rup Calc=IAABuilding Front faces: S 2017-Dec-05 10:43:29 Page 1 B f1 S 1st Floor P ila I: Il li Il Dining/Kitchen a [ Bed P114 cfm ; Ll11 { ii v, 1 f1 is � ., �,• cfm 114c� : Si Z.-, gii t4P4 ''''''.: \t, 4 Bath 1 � �� tr I! Riser 12so cfim Job 4: Performed for: Exclusively for the use of: Scale: 1 :58 Roads Garage Remodel Page 1 1147 Beach Ave A Comfortable Environment Right-SuiteC Unlversa12C17 Atlantic Beach, FL 17.0.1 RSU17457 2017-Dec-05 1C:52:32 .,.de.. 1147 Beach Ave.Atl Bch.rup rd. 1. 2nd Floor 1 j' 1 14 1 o i$ :f y� q 3 q Kitchen/Dining i; t. Living ri a a I ri 1 _; \JI tet' 1 t 1 cfm7 18 's ti 10 , `~ 4_. _fi _.,:`,-,f--. -ir ii i �t t Na sz. Aed fil a2 ,}5-,'p-r c '' P 7 j R 140 cfm 12 Le--34j P =?fir JV r to gY ta .4Pi 12x12 �' il rW. II it f M I.1 l'-`1 154 cfm 1 12x12 H 118 cfm Fi i:1 Bed 2 Master Nook 3 C {{3 1 • �y ,__• Job#: Performed for: Exclusively for the use of: Scale: 1 :58 N:onlds Garage Remodel Page 2 1147 BeachAve A Comfortable Environment Right-Suitete Universal 2C17 Atlantic Beach. FL 17.C.17 RSU17457 2017-Dec-05 10:52:32 ...de!. 1147 BeachAve.AU Bch.rip - - wrightsoft Duct System Summary Job: Entire House Date: By: Exclusively for the use of: A Cornbrtable Environment IMMO .. t.. ...�•,. .F.,..�.�� ,M>..>s .,.. 0�r4§1 r.x r,. c $,.3 sirr.. 2i2. e: ' y:. For k_r. �: ` < r Htonidis Garage Remodel ��" ��--== 1147 Beach Ave.Atlantic Beach. FL External static pressure Heating �� Cooling y Pressure losses 0.10 in H2O 0.10 in H2O Available static pressure 0 in H2O 0 in H2O Supply/return available pressure 0.10 in H2O 0.10 in H2O Lowest friction rate 0.060/0.040 in H2O 0.060/0.040 in H2O Actual air flow 0.058 in/100ft 0.058 in/100ft Total effective length (TEL) 1200 cfm 1200 cfm 173 ft __'�`�- --_' :.`�.___ s .. . •i' 4 y MSS.! �...r.!::_, ....•-� ''s...,147.'j#, i4 Name Design f ) FR Design I Diam H x W Duct Actual Ftg.Eqv Btuh (cfm) ( (in) (in) Matl Ln (ft) Ln (ft) Trunk Bath t 67h Bath 1 c 14901 72 0.061 4.0 Ox 0 VIFx 23.6 75.0 srsl Bed h 2630 I 55 57 0.061 4.0 Ox 0 VIFx I 104 96 0.058 6.0 Ox 0 23.4 I 75.0 srsl I I Bed 2 c 4067 153 154 I 0.058 7.0 Ox 0 VIFx 28.4 75.0 srsl I Dining/Kitchen h 28801 114 I VIFx I 28.6 75.0 srs1 I Hall-A 106 0.061 6.0 Ox 0 VIFxI C 197 6 7 0.064 7.0 23.0 75.0 srsl Kitchen/Dining c 4395' 158 167 Ox 0 VIFx I 19.0 75.0 srsl Living 0.066 7.0 Ox 0 VIFxI c 4776 172 181 0.060 7.016.3 75.0 srs1 Lit.iaster Bed c 3676 136 I Ox 0 VIFx � 25.0 75.0 Srs1 � aster Bedk. 140 0.066 7.0+ Ox 0 VIFx c 3116 118 118 0.062 7.0 I Ox 0 VIFx I 16.0 75.0 srsl Sitting h 2880 114 106 0.064 6.0 22.4 75.0 srsl Ox 0 VIFx 19.2 ...''';'''''''''''L-1.---.:t-';.a ;.I •,. �-e" A;1:;!%;,.'17,-'1't:,1•;•-•;.': .:,::,-7,,, A 'r t'v '' : ' -.; - _ .� -Ia i "� F �'- _...._..,_.;-rte ' i�s�"':� , Fx_ �t ( Grille Htg I Clg I TEL Design Veloc Diam H x W I Stud/Joist I Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb3 Ox 0 391 412 69.2 0.058 756 10.0 Ox 0 VIFx rrsl I rb4 ( Ox 0 1 406 412 62.2 1 0.064 525 12.0 Ox 0 (VIFx (rrsl I rbl Ox 0 403 375 61.0 0.066 377 14.0 Ox 0 I VIFx I rrsl J F Trunk Htg I Gig I Design I Veloc Diam I H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rrsl Peak AVF 1200 1200 0.058 1528 12.0 0 x 0 ViniFix Bold/italic values have been manually overridden 1 I l Wrightsofr Right-Suite®Universal 2017 17.0.17 RSU17457 2017-Dec-05 10: 2:16 Paas 2 ACC\ ...dis Garage Remodel,1147 Beach Ave.All Bch.rup Calc=h9..18 Building Front faces: S iciai Epazuoynssuolon4 luyoM :- i IIU3 3003 v GII"V 31N!tmuml8y gsao7 of iuensind yid S0 i1 iS10z'IInt uo s�lt3 �yyA9 ip >�:1Q3A23S?N SLHJRI 7Zd!DDi'�q Ivsai11�O'01143j CO VO-ti (t'log)NOWQ3 41S'NOLLVAt13SN00 AO 3N3—3000 0N1011f13 1101801 ' 1-G-�S/ :ete0 �� �aWa = 1N3JV/ti3NM0 :1V131dA0 3000 'uouenrasuo0 AB/airs'epo0 I 'Aos ugtoeS UUM eouep.000e 6u/plfn9 epU0L4 e4t 411m eousildwoo te sl but situ W4l Ambito Agway 1 ul aoueildwoo Jol peloedsw eq Illm butptmq elgl'eleldwoo sl uoyorulsuoo -ele0 I eJo{ed wouenies LI I'Z1 11 :A80 lldwoo d uoJ�6zeu3'BPoO burp/fog epuol3 e4141!m aou¢lidwoo •uogaivasuo0,t6�eu3`epo0 6ufptfng epuo/j e44 4ilm eou¢Ilduwo ul ateolpul uuol slit Aq pelenoo suotleoµioeds pue tumid 40 metned ere uuo{4141 Aq paueA00 suoµeoµloeds pue sued e41 Wit A{IlJao AgeJe4 1 C As'. Anueio�lla(9 .. Sive 00 'es adAl(e :wetaAn buttee4 JeWM 'sl ❑oN seA '6 I _ l peyoape:ual¢Inot¢o Bulzla 3VAH "tl Z•8 .cis I. :Aoue!o41a(q I d ' dyi-' -eel adAI(a :welsAs BulteeH 'EL Yp1i.'1 � 'qZl Aoueaywa(q t 44u-)ra! -fit edAl(e :wetsAs 6ulloo0 Zl I 0 oN ❑saA '1's OOl1wp 'oil 'paIpeue doge/lsel'abemeei loop 15401 (0 I •A°V-41.4= 'III ll uoneool f1HV (q 'ell. uoyelnsui'uogeool tong (a :walats uopngluefp nv 'll I 'qOL (amen-d uonelnsui)Aigwasse opus (q eOl (amen-a uogelnsul)361V (e uotWlnsul pus edA4 6ullleO 'DI. 2q6 (Solan-a uonelnsul)AJuosey{ -Z 'lq6 (amen-et uonelnsul)awey pooM t zuaoefpV (q "Ze6 (amen-ei uonelnsul)Auuoseyy .Z L 1 Zi z 'le6 (amen-a uonelnsul)awe.4 pooh I, Joualx3 (e :uoµ¢insw pus edAl IIeM "6 "e9 (amen-Z/)uowwoo'alaJou00 (a s a (amen-a)poser'steouo3 (P 00 (amen-y)uowuroo'pooh (o I "Qe (amen-N)pesieJ'pooM (q I "ee (anlen-N)ape16-uo-ge1S (e :uolpetnsul pue'Jetewped.8o eau'edAl loci i 'e — 'qL (09HS(luarouteo3 ule0 le9H Jelos (q I 'eL Joloe{-n (e LZ o9 st !1A11S 'L I 11•I --- --- --- eaJV (o I St.'s (19 (39HS)luaio ao3 we91eaH JeloS (q 0 f.•3; 'e9 Joloel-fl (e tf rJ lZ S ewe pue edA4'smopulM '9 ('u'bs)eaJe Dooµpeuolllpuo0 's 1.4 a (oWaeA)tes¢o tsJoM a s141 el 't E uotsslwgns suit Aq peJenoo shun to Jegwnu'Altwe{-aldll(nw{1 •E I 41 bt.r—ICAR .z Pegoeue Allwet-etdtitnw Jo pagoelep A11wei-elBeIS 'Z I I+S 7r: 'I. 6ulp1mgbuiiatxeJo'uoll,ppe'ualorulsuoomew 't I -uuoy e4p elep pue u6ls ow renes plebe 8,1eumo Jo JeuMo ell'1.abed{o urouoq eq te luewetete uolleolilpeo„AH peJedeud..e44 elep pus ubis`peed't I 'swell elgeolldde He 4µm Aldwoo of tue ul mnoA aleolpul 01 xoq tpee itoego pus BZOtd epel to sluewelinbai eql peed'e I 'uotteuuolul uwnloo„pelletsul e8 oL,eut uo peseq t abed eleldwo0 2 '819501 peilnbeJ out ue414ueloµta a.1ow JO 04 lenbe I aq lsnw sanleA„pellelsut as 01..Hy'palsenbel uoueuuotut 941 U4IM VZOtd a1ge1 uo uwmoo„pellelsul ae 01..aqt to seoeds apeoildda au'He ul III d't I .800001111SM teJeUe0 I :d38WIlN 111'ld3d I 00 1 1 O)li :d38Wf1N Nouplasitiflf 11-0 17 7L1.NvHAI, :331J300NIJ11Wd3d :d3NMO 1 O :43011013 ?AV tr3-trdg bbz, SS3d00tl 0NV I V01-F12/10(.f2ZI S./.10?1,4°!1-1 :3WVN133PObd I •uogeiuesuo0 Afueu3'4400 6urppng eppoid 24140 s014 eeSoes J2pun Aldwoo pgs Aew 11'p0412w 2AgeuJagV V fl a4p Aq Jo'pometu 8141 41iM AIdwoo lou scop 6ulpilnq all'two;slip to 8ZOt,2!ape j ul pazuewwns sluewaumbei Alolepuew algeolldde lie pue yZOg21 ape j_uo I sluaweumbeJ Aoueloy}e ABleue etg Jo lie pseoxe to Joao pow 6ulplmq a'Aldwoo 01.aIQeoydde se's6ulpllnq 6ugsixe ul swalsAs 5U1pt nq pue I `suopenoual'suoge.lalie's6uip inq lenuaplseJ 6ugslxe of suoglppe`146124 Li!ssal Jo sauois 89144)o saouepisai A11we1-aidglnw pue-016uls.104 I Z01V21 uw °a od sn 041 Aq palegsuowap aq 11848'loge vasuo0 d6ueu3'ep00 8uippn8 epu )j oa4110 I. VZ0e2)uol4oag yllm eoue1idwo0:Woosi $UOZ 61e111l)3 VIUZ-Zoba WlJO3 I yoeoJddd adojenu3 'mamma 6ulppg je!Waplsea 1 NOIiVAb3SNOO AOS3N3 `3000 ONIQ71118 VQWO73 Swaod Ad 03.:3 Q,1�> :. . r • k . -- , h FORMS ll TABLE R402A I ' BUILDING COMPONENT PRESCRIPTIVE REQUIREMENTS' INSTALLED VALUES ' Climate Zone 1 Climate Zone 2 Windows: U-Factor=0.652 U-Factor=0.402 1 I SHGC=0.25 SHGC= = .2O Skylights SHGC=025 ' U-factor=0.75 U-factor=0.65 U-factSHGC C r .2.5 SHGC=0.30 SHGC = I SHGC=0.30 SHGC= Doors:Exterior door U-factor=0.65' U-factor=0.40' IUfactor- Floors: Slab-on-Grade NR NR I Over unconditioned spaces` R-13 R-f3 I�_` a-11 ' R-Value= Yti0 (.. C S Wafts':Ext and Adj. _ F Frame R-13 Mass R-13 R-Value= Insulation on wall interior. R-4 R-6 Insulation on wall exterior R-3 R-4 R-Value= I Ceilings': R=30 R-38 • R-Value= R-Value= ' Air infiltration: Blower door test is required on the buildingenvelope ape to verify leakage 5 5 ACH: Total leakage=ACH I test report provided to code official. � Testret Attached? ' Air distribution system': Yes D No❑ Air handling unit Not allowed in attic I Duct R-value R-value>R-8(supply in attics)or>_ EA Location: E.}. 4l or R-6(all other duct locations} R-Value= sAi .01 `.! I Air leakage': Duct test Postconstruction test: Total lea 5 Rou h-ru test �e 4 dm/100 s.f. Total leakage= dm/100s.f. Ducts in conditioned space Test not required if all ducts and�AHU are In conditioned space Lostreport Attached? Yes 0 No 0 Location: ' Air conditioning system: Minimum federal standard required by NAECA°. Central system 565,000 Btu/h SEER 13.0 ' Room unit or PTAC EER[from Table C403.2.3(3)) SEER= I4 I Other. See Tables C403.2.3(1)-(11) EER= Heating system: Minimum federal standard required by NAECA° Heat pump 5 65,000 Btu/h HSPF 7.7(before 1/1/15);HSPF 8.2(as of V1/15) p Gas furnace,non-weatherized AFUE BO% FUE= 8•Z I Oil furnace,non-weatherized AFUE 83% AFUE • _ ' Other. AFUE= Water heating system(storage type): Minimum fedIeral standard req uired by NAECA' Electric' 40 gal:EF=0.92 1 ' ° 50 gal:EF=0.90 Gallons= Ex..;S T 7 YtQ Gas fired 40 gal:EF=0.59 EF= r J 50 gal:EF=0.58 Gallons= Other(describe): EF= I ' NR=No requirement. (1)Each component present in the As Proposed home must meet or exceed each of the applicable performance criteria in order to comply with this code using this method. (2)For impact rated fenestration complying with Section R301.2.1.2 of the Florida Building Code,Residential or Section 1609.1.2 of the Florida Building Code, Building the maximum U-factor shall be 0.75 in Climate Zone 1 and 0.65 in Climate Zone 2.An area-weighted average of U-factor and SHGC shall be accepted to meet the requirements,or up to 15 square feet of glazed fenestration area are exempted from the U-factor and SHGC requirement based on ' Sections R402.3.1,R402.3.2 and R402.3.3. (3)One side-hinged opaque door assembly up to 24 square feet is exempted from this U-factor requirement. I (4)R-values are for insulation material only as applied in accordance with manufacturers'installation instructions.For mass walls,the"interior of wall" ' requirement must be met except if at least 50 percent of the insulation required for the"exterior of wall"is installed exterior of,or integral to,the walL (5)Ducts&AHU installed"substantially leak free"per Section R403.2.2.Test required by an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes.The total leakage test is not required for ducts and air handlers located entirely within the building thermal ' envelope. (6)Minimum efficiencies are those set by the National Appliance Energy Conservation Act of 1987 for typical residential equipment and are subject to NAECA rules and regulations. For other types of equipment, see Tables C403.2.3(1-11)of the Commercial Provisions of the Florida Building Code, Energy ' Conservation. I (7)For other electric storage volumes,min.EF=0.97-(0.00132'volume). (8)For other natural gas storage volumes,min.EF=0.67-(0.0019*volume). R-CA FLORIDA BUILDING CODE—ENERGY CONSERVATION,5th EDITION(2014) INTERNATIONAL COUNCIL CODE COCopyright to,or licensed by,ICC(ALL RIGHTS RESERVED);accessed by Maggie Ellis on Jul t 2015 1:11:05 PM pursuant to License Agreement. CODE V U 111r 1 L No further reproductions authorized. - Job: wrightsoft Manual S Compliance Report Entire House Date: 11/21/17 By: M.Ellis Energy Design Systems, Inc. 11727 Brady Rd.Jacksonville, FL 32223 Phone:904-268-3670 Fax:904-268-3670 Email:ads.jax@gmaii.com Project Information For: Hionidis Renovation 1299 Beach Ave.Atlantic Beach, FL Cooling Equipment Design Conditions Outdoor design DB: 94.4°F Sensible gain: 49851 Btuh Outdoor design WB: 77.4°F Latent gain: 4993 Btuh Entering coil DB: 64.0°F Entering coil WB: 64 Indoor design DB: 75.0°F .0°F Indoor RH: Total gain: 54844 Btuh 50% Estimated airflow: 1900 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Comfortmaker Model: N4H460GKG**+FXM4X60**AL Actual airflow: 1900 cfm Sensible capacity: '11460 Btuh 89% of load Latent capacity: 12540 Btuh 251% of load Total capacity: 57000 Btuh 104% of load SHR: 78% Heating Equipment Design Conditions Outdoor design DB: 38.1°F Heat loss: 36342 Btuh Indoor design DB: 68.0°F Entering coil DB: 67.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Comfortmaker Model: N4H460GKG**+FXM4X60**AL Actual airflow: 1900 cfm Output capacity: 54500 Btuh 150% of load Supplemental heat required: 0 Btuh Capacity balance: 28 °F Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1900 cfm Output capacity: 10.7 kW 101% of load Temp. rise: 99 °F Meets are all requirements of ACCA Manual S. wrightsoft- Right-Suite®Universal 2017 17.0.17 RSU17457 2017-Dec-01 15:43'27 ..ionidis Renovation, 1299 Beach Ave,All Bch.rup Calc=MJ8 Front Door faces: W Page 1 - - wrightsoft Project Summary Job: Entire House Date: 11M.El By: M.Ellis 17 Energy Design Systems, Inc. 11727 Brady Rd,Jacksonville, FL 32223 Phone: 904-268-3670 Fax:904-268-3670 Email:eds.jax@gma,I corn Pro'ect Information For: Hionidis Renovation 1299 Beach Ave.Atlantic Beach. FL Notes: Desi. n Information Weather: Mayport Ns. FL. US Winter Design Conditions Summer Design Conditions Outside db Outside db Inside db 68 °F Inside db 7745 °F Design TD 30 °F Design TD 19 °F Daily range L Relative humidity 50 Moisture difference 50 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 25715 Btuh Structure 34057 Btuh Ducts 10627 Btuh Ducts 15794 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower Pi in 0 Btuh Equipment load 36342 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 49851 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1541 Btuh Ducts 3453 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area (ft2) 2113 2113 Equipment latent load 4993 Btuh Volume (ft') 16904 16904 Air changes/hour 0.39 0.16 Equipment total load 54844 Btuh Equiv.AVF (cfm) 110 45 Req. total capacity at 0.83 SHR 5.0 ton Heating Equipment Summary Cooling Equipment Summary Make Comfortmaker Make Comfortmaker Trade COMFORTMAKER Trade COMFORTMAKER Model N4H460GKG*" Cond N4H460GKG" AHRI ref 9658602 Coil FXM4X60**AL AHRI ref 9658602 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 39900 Btuh Heating output 54500 Btuh @ 47°F Latent cooling 17100 Btuh Temperature rise 26 °F Total cooling 57000 Btuh Actual air flow 1900 cfm Actual air flow 1900 cfm Air flow factor 0.052 cfm/Btuh Air flow factor 0.038 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.91 Capacity balance point = 28 °F Backup: Input = 11 kW. Output = 36627 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrightsoft` Right-Suite®Universal 2017 17.0.17 RSU17457 2017-Dec-01 1543:27 Y" ACCP. .ionidis Renovation, 1299 Beach Ave,Atl Bch.rup Calc=MJ8 Front Door faces: W Page 1