577 COASTAL OAK LN - LEAKAGE REPORT FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Project Name Atlantic Beach Country Club (lot 87) Builder Name: Toll Brothers Street: 577 Coastal Oak Lane Permit Office: City,State,Zip: Atlantic Beach. Fl. 32233 Permit Number. Owner: Jurisdiction: Design Location: ) , 2 3 9�'3 Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): 2475 Multi Point Test Data: ELA: HOUSE PRESSURE FLOW: 1 50 Pa 2475 cfm EgLA 2 Pa cfm ACH: 3 Pa cfm ACH(50): 6.3 4 Pa cfm SLA: 5 Pa cfm 6 Pa cfm 402.4.2.1 Testing option. Building envelope tightness and insulation installation shall be considered acceptable when tested air leakage is less than seven air changes per hour(ACH)when tested with a blower door at a pressure of 33.5 psf(50 Pa).Testing shall occur after rough in and after installation of penetrations of the building envelope,including penetrations for utilities,plumbing,electrical,ventilation and combustion appliances. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed; 2.Dampers shall be closed,but not sealed,including exhaust,intake,makeup air,backdraft and flue dampers; 3.Interior doors shall be open; 4.Exterior openings for continuous ventilation systems and heat recovery ventilators shall be dosed and sealed; 5.Heating and cooling system(s)shall be turned off; 6.HVAC ducts shall not be sealed;and 7.Supply and return registers shall not be sealed. Florida Building Code requires `••••' EKE ST '' • I hereby certify that the above envelope testing to confirm envelope leakage �•• .- •;9T6•�``•; leakage performance results demonstrate be performed by a Class 1 ~ ',,. „;' f.. O�, compliance with Florida Energy Code = co "'' Florida Energy Gauge Certified ;F. ',, ,�`c,,;; °.., , requirements in accordance with a>c' :;,,. Section Table B-1.1.2. Energy Rater. Certified Florida a _ 6 .. Class 1 raters can be found at: ,_0 ;s http://energygauge.com/search.htm : .`. Signature: Printed Name: Daniel Brohl Florida Rater Certification it: 2501093 BUILDING OFFICIAL: DATE: 9/26/2018 DATE: EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software