577 COASTAL OAK LN - LEAKAGE REPORT FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Project Name Atlantic Beach Country Club (lot 87) Builder Name: Toll Brothers
Street: 577 Coastal Oak Lane Permit Office:
City,State,Zip: Atlantic Beach. Fl. 32233 Permit Number.
Owner: Jurisdiction:
Design Location: ) , 2 3 9�'3
Envelope Leakage Test Results Leakage Characteristics
Regression Data:
C: n: R: CFM(50): 2475
Multi Point Test Data:
ELA:
HOUSE PRESSURE FLOW:
1 50 Pa 2475 cfm EgLA
2 Pa cfm ACH:
3 Pa cfm ACH(50): 6.3
4 Pa cfm SLA:
5 Pa cfm
6 Pa cfm
402.4.2.1 Testing option. Building envelope tightness and insulation installation shall be considered acceptable when tested air leakage is less
than seven air changes per hour(ACH)when tested with a blower door at a pressure of 33.5 psf(50 Pa).Testing shall occur after rough in and after
installation of penetrations of the building envelope,including penetrations for utilities,plumbing,electrical,ventilation and combustion appliances.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed;
2.Dampers shall be closed,but not sealed,including exhaust,intake,makeup air,backdraft and flue dampers;
3.Interior doors shall be open;
4.Exterior openings for continuous ventilation systems and heat recovery ventilators shall be dosed and sealed;
5.Heating and cooling system(s)shall be turned off;
6.HVAC ducts shall not be sealed;and
7.Supply and return registers shall not be sealed.
Florida Building Code requires `••••' EKE ST ''
•
I hereby certify that the above envelope testing to confirm envelope leakage �•• .- •;9T6•�``•;
leakage performance results demonstrate be performed by a Class 1 ~ ',,. „;' f.. O�,
compliance with Florida Energy Code = co "''
Florida Energy Gauge Certified ;F. ',, ,�`c,,;; °.., ,
requirements in accordance with a>c' :;,,.
Section Table B-1.1.2. Energy Rater. Certified Florida a _ 6 ..
Class 1 raters can be found at: ,_0 ;s
http://energygauge.com/search.htm : .`.
Signature:
Printed Name: Daniel Brohl
Florida Rater Certification it: 2501093 BUILDING OFFICIAL:
DATE: 9/26/2018 DATE:
EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software