1719 BEACH AVE - POOL DRAWINGS1719 BEACH AVE' OFFICE COPY ATLANTIC BEACH, FLORIDA (SINGLE FAMILY HOME) LOT = 13624 SQFT IMPERVIOUS ROOFED STRUCTURE = 810 SQFT IMPERVIOUS PAVER DRIVEWAY/WALKV AY = 2221 SQFT PERVIOUS PAVERS = 258 SQFT POOL COPING = 48 SQFT POOL = 291 SQFT TOTAL IMPERVIOUS = 6239 (45.7%) INDEX I OF 9 PAGE 1 COVER SHEET PAGE 2 CLEARANCE SHEET/SURVEY PAGE 3 POOL PLAN PAGE 4 APSP SHEET PAGE 5 TDH SHEET PAGE 6 MAIN DRAIN CUT SHEET PAGE 7 INTELLIPRO CUT SHEET PAGE 8 PLM CUT SHEET PAGE 9 ENGINEERING PACKET B�N � r� 5002 Pklllps ri4 wa, Jacksonville, ft 3220' ( 904) 858-4300 www, c raver vod s iru , cern rtyI510N5: P! 1MCtp M'm,15 PATS pp.0_tef INFOC W-1 UN PWING T fll,�, CO'M'ER 5VT PRO.fcf: MLLAMY 1719 GRACH AVE ATLANTIC LtACH k1 51-ikEt, I OF 9 PAl' 9,13.18 PrIMN ff. HWGS GENERALNOTES i. 2. 3. 4. 5. 6 7. S. 9. 10. 11. 12. 13. FOR POOL PLAN. S SIZE. DECK EXTENTS. SPECIAL DETAILS, SEE CONTRACTORPOOL PLAN ALL POOL CONSTRUCTION SHALL COMPLY WITH FLORIDA BUILDING C BUILDING 2014 AND FLORIDA BUILDING CODE RESIDENTIAL 2014 TOGETHER WITH LATEST REVISIONS JD ANSWJSPI NATIONAL STANDARDS FOR RESIDENTIAL INGROUND SWIMMING POOLS AND ANS. -PI NATIONAL STANDARD -3 FOR PERMANENTLY INSTALLED RESIDENTIAL SPAS AND THE NATIONAL ELECTRIC CODE - LATEST. ALL POOL PIPING TO BE SCHEDULE 40 OR 80 PVC BEARING NSF APPROVAL UNLESS OTHERWISE NOTED. THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR POOL CONSTFUCTION IN EASEMENTS OR REQUIRED SETBACK AREAS. POOL CONTRACTOR AND/OR OWNER SHALL VERIFY LAYOUT AND ALL DIMENSIONS SHOWN PRIOR TO CONSTRUCTION. CONTRACTOR SHALL DETERMINE LOCATION OF ALL UTILITIES IN RELATION TO POOL AND ITS EQUIPMENT AND ENSURE MINIMUM CLEARANCE IN ACCORDANCE WITH LOCAL REGULATIOIN S AND ORDINANCES. CONTRACTOR SHALL PROVIDE ADEQUATE TEMPORARY FENCING AROUNC CONSTRUCTION AREA TO PREVENT UNAUTHORIZED ENTRY INTO POOL AREA. IF A MANUAL FILL WATER SUPPLY IS PROVIDED, A MINIMUM 3" ATMOSPI-E IC BREAK WILL BE PROVIDED IF AN AUTOFILL ASSEMBLY IS INSTALLED, A BACKFLOW PREVIEW WILL B REQUIRED ON THE POTABLE WATER LINE USED TO SUPPLY THE POOL. ALL STRUCTURAL. FILTRATION, AND ELECTRICAL DETAILS OUTLINED IN ESE DRAWINGS ALSO RELATE TO SPA CONSTRUCTION. ALL POOL AND SPA HEATERS SHALL BE EQUIPPED WITH A READILY ACCESSIBLE ON-OFF SWITCH MOUNTED OUTSIDE THE HEATER TO ALLOW THE HEATER TO BE SHUT OFF WITHOUT ADJUSTING THE THERMOSTAT SETTING AND TO ALLOW RESTARTING WITHOUT RE -LIGHTING THE PILOT L GHT. EFFICIENCY RATINGS MUST COMPLY WITH THE FLORIDA ENERGY CONSERVATION CODE. TO EMPTY THE POOL FOR ANY REASON, THE HYDROSTATIC UPLIFT PRESSURE MUST BE ELIMINATED. THE OWNER MUST CONSULT A CONTRACTOR EXPERIENCED IN ELIMINATING UPLIFT PRESSURE. CONTRACTOR SHOULD CONSIDER INSTALLATION OF GRAVEL BED WITH UNDERORAIN PUMPING SYSTEM IN AREAS WHERE GROUNDWATER COULD RESULT IN UPLIFT PRESSURES THAT COULD FLOAT POOL OUT OF THE GROUND.. THE RESIDENTIAL SWIMMING POOL BARRIER AND/OR ITS COMPLIANT SAFETY COMPONENTS SHALL BE IN PLACE PRIOR TO FILLING OF THE POOL. FRC R4101.17 CODE VIOLATIONS FOUND DURING INSPECTION ARE REQUIRED TO BE CORRECTED. PLANIPERMIT ISSUANCE DOES NOT GRANT APPROVAL OF A CODE VIOLATION. 2014 FRC 109.1 A HYDROSTATIC RELIEF VALVE SHALL BE INSTALLED IN POOLS LOCATED 14 AREAS WHERE THE GROUND WATER TABLE OR POTENTIAL PERCHED WATER INTERSECTS THE POOL DURING ANY PERIOD OF ANY GAN YEAR. STRUCTURAL NOTES 1 2. 3. 4. 5. 6. 7. 8. 9. 16, 17. ALL REINFORCING STEEL TO CONFORM TO ASTM 615 GRADE 40.REINF CrINSHALL BE #3 BARS AT 10. ON CENTER EACH WAY WITH 15" LAP JOINT IN WALLS AND FLOORS UP TO F .ET DEPTH. BETWEEN 6' AND 10, USE #3 BARS AT 5" ON CENTER VERTICALLY IN THE AREA OVER 6' IN DEP {. (ALTERNATE: #4 BARS AT 12" ON CENTER EACH WAY WITH 2(- LAP JOINT IN WALLS AND FLOORS UP TO 11 FEET IN DEPTH: BETWEEN 6' AND 10', USE 04 BARS AT 6" ON CENTER VERTICALLY IN THE AREA OVER FIN DEPTH) NOTE APPLIES TO NORMAL. NON -EXPANSIVE SOILS ONLY. NORMAL SOILS ARE ASSUMED TO POSSESS EQUIVALENT FLUID PRESSURE OF 35 PCF AND UNIT WEIGHT OF 120 PCF. IF CONCRETE IS CASTAGAINST BARE EARTH WITHOUT SEPARATION BARRIER, MINIMUM COVER SHALL BE 3 WITH A BARRIER (STEELTEX) BETWEEN CONCRETE AND EARTH, MINIMUM COVER SHALL BE 2'. POOL WALLS SHALL BE MIN. 6" THICK AND FLOORS SHALL BE MIN. 6THICK AND SHALL BE PNEUMATICALLY APPLIED CONCRETE WITH A COMPRESSIVE STRENGTH OF 4,000 PSI IN 28 S. CONCRETE DECK SHALL BE 2,500 PSI. CONCRETE CONSTRUCTION WILL CONFORM TO ACI STANDARD 318. MINIMUM WALL THICKNESS MUST BE INCREASED FOR DEPTHS GREATER THAN 8'0". NOTE APPLIES TO "NORMAL" SOILS ONLY. POOL OR PATIO SHALL BEAR ONLY ON ROCK OR CLEAN SAND, WHICH S -L BE COMPACTED TO PROVIDE A STRUCTURALLY SAFE BEARING CAPACITY. ANY UNSUITABLE MATERIAL ENCOUNTERED IN EXCAVATION SHALL BE REMOVED IN ITS ENTIRETY AND THE AREA SHALL BE BACKFILLED WITH ACCEPTABLE MATERIAL AND PROPERLY COMPACTED. WHERE UNSUITABLE MATERIAL CANNOT BE REMOVED, THE POOL MUST BE REDESIGNED. SOILS SHALL HAVE MINIMUM BEARING VALUE OF 1000 PSF, 1500 PSF FORREESTANDING WALL. THE CONTRACTOR MUST PROTECT EXISTING STRUCTURES FROM FAILURE BY ACCEPTABLE METHODS. THE DESIGN ENGINEER ACCEPTS NO RESPONSIBILITY FOR THE SAFETY OF EXISTING STRUCTURES. CONTRACTOR SHOULD CONSULT WITH A STRUCTURAL ENGINEER IF EXIS17ING STRUCTURES HAVE THE POTENTIAL TO INFLUENCE FORCES ON THE POOL WALL, OR VICE VERSA. SHOTCRETE (WET OR DRY) SHALL BE PROPORTIONED AND PLACED ACCO 1DING TO UBC SECTION 1922 AND ACI 506. CEMENT TO AGGREGATE, IN DRY WEIGHT, SHALL NOT BE LESS P AN FIVE TO ONE, SHOTCRETE SHALL NOT BE APPLIED IF AMBIENT AIR TEMPERATURE IS LEI S THAN 40F AND FALLING, OR IF TEMPERATURE IS GREATER THAN 100F. NEVER APPLY SHOTCRETE IN HU VY RAIN. SUBSTRATE SHOULD BE FOG -SPRAYED WITH WATER PRIOR TO SHOTCRETE APPLICATION TO ALLOW HYDRATION AND LIMIT RAPID DRYING OF CONCRETE, AND TO COOL REINFORCEMENT STEEL. IF FLOOR IS TO BE POURED AND WALLS CONSTRUCTED WITH SHOTCRETE THE FLOOR SHALL BE POURED PRIOR TO CONSTRUCTION OF THE WALLS. FOR SHOTCRETE FLOORS, APPLICATIONSHOUl D COMMENCE IN CORNERS AND WORK TOWARDS THE CENTER OF THE POOL FOLLOWING ALL CONSTRUCTION. IF EXPANSIVE SOILS (CLAYS) ARE ENCOUNTERED, THE SIDES AND BOTTOM OF THE POOL EXCAVATION MUST BE IN MOIST CONDITION IMMEDIATELY PRIOR TO PLACEMENT OF SH )TCRETE. REINFORCEMENT STEEL SHALL MEET ASTM A615-40. LAP SPLICES SHALL AT LEAST 40 BAR DIAMETERS. ALL BENDS MUST BE SHARP. UBC SECTIONS 1907, 1912, AND 1924 SHALL USED AS A GUIDELINE. LAP SPLICES SHALL BE STACKED INLINE WITH SHOTCRETE SPRAY DIRECTI N. NOT SIDE-BY-SIDE PERPENDICULAR TO SPRAY. REBAR PLACEMENT SHOULD BE SUCH THAT THE DISTANCE FROM THE I DE SHOTCRETE FACE TO REBAR SHOULD BE A MINIMUM OF THE TOTAL SHOTCRETE THICKNESS MINUS 3". IN AREAS WHERE THE STEEL REINFORCEMENT IS FORCED TOGETHER DU TO CURVATURE OF THE WALL, 1 - #4 BAR MAY BE SUBSTITUTED FOR 2 - #3 BARS IN ORDER TO MAINTAIN A INIMUM 2.5 INCH SPACING. UP TO 2" DIAMETER PIPING MAY BE PLACED IN THE LOWER OUTSIDE CORN °R OF THE BOND BEAM PROVIDED A MINIMUM OF 1.5 INCH CLEARANCE IS MAINTAINED BETWEEN THE PIPES AND ANY PARALLEL REINFORCEMENT. AN ENGINEER SHOULD BE CONSULTED IF UNUSUAL CONDITIONS ARE ENC )UNTERED. IF A RAISED BOND BEAM EXCEEDS 70' AND SERVES AS A RETAINING WALL�FOR SOIL, THE RAISED PORTION SHOULD HAVE WALL DRAINAGE INSTALLED TO PREVENT BUILD-UP OF HYDROSTATIC PRESSURES. MINIMUM REINFORCEMENT 03 SEE STRUCTURAL NOTE 5 BARS SPACED 10" O.C. E.W. TYPICAL POOL X TO B' DEEP TYPICAL SHOTCRETE S I EPS OR ' BENCHES AS NVEDED---_ EXTRA TRANSVERSE REINFORCEMENT43 10' LENGTH SPACED ON 10* CENTERS BETWEEN MAIN BARS, CENTERED ON TRANSITION (MAY BE ELIMINATED IF NO TRANSITION EXISTS) 143 DIAGONAL. E.W. AT DRAIN SIMILAR TO LIGHT -NICHE DETAIL - LONGITUDINAL POOL SECTION NTS ADJUSTABLE FLOOR INLET. ! FNGSWD POOL / AFTER FULL CLOSE, BACK OPEN 1/ 112 TURN. (FLOOR INLETS SHALL BE FLUSH WITH POOL FLOOR.) I-_ SUPPLY HEADER NOTE: CONCRETE ENCASEMENT OCCURS ONLY AT THE RETURN FITTING. POOL FLOOR INLET DETAIL N. T. S. La Z f 1AM" X e n OFFICE COPY Z m N 8"-11" ESCUTCHEON PLATE ANCHOR SOCKET 44 DIL (NO VOIDS) RUBBER BUMPER 6' MIN. TYPICAL SWIMOUT DETAIL N.T.S. THE FOLLOWING TABLE PROVIDES MAXIMUM FLOW THROUGH SCH 40 PVC PIPE WITHOUT EXCEEDING THE MAXIMUM STANDARDS FOR VELOCITY (FT/SEC) PIPE SIZE 6 FT/S 8 FT1S 10 FT/S 1" 16 GPM 21 GPM 26 GPM 1}4" 37 GPM 50 GPM 62 GPM T 62 GPM 82 GPM 103 GPM ZW 1 88 GPM 117 GPM 146 GPM 3" 138 GPM 181 GPM 227 GPM 4" 234 GPM 313 GPM 392 GPM 6" 534 GPM 712 GPM 900 GPM PUMP SIZE WILL VARY DEPENDING ON THE PUMP SPECIFICATION AND THE TOTAL DYNAMIC HEAD FOR THE SPECIFIC POOL NEEDS. WATER LEVEL (CENTER LINE OF SKIMMER) SPRING LOADED VERTICAL z EQUALIZER FITTING IANT CHECK EQUALIZER VALVE - A E (IF INSTALLED) ORATE (IF INSTALLED) TO PUMP SUCTION VACUUM FITTING -SEE NOTE 3 BELOW NOTES: I 1. SKIMMER SHALL BE VENTED TO ATMOSPHERE THROUGH OPENINGS IN THE LID, THROUGH AN ENGINEERED VENT PIPE, OR INCORPORATE AN EQUALIZER LINE. 2. EQUALIZER LINES, WHEN USED, SHALL BE LOCATED ON THE WALL WITH THE CENTER NO MORE THAN 18' BELOW THE MAX. OPERATING LEVEL. IT SHALL BE PROTECTED BY A VGB COMPLIANT COVER/GRATE. IF THE EQUALIZER LINE AND FITTING ARE NOT INSTALLED, THE SKIMMER PORT MUST BE PLUGGED. 3 WHEN USED, VACUUM CLEANER FITTINGS SHALL BE LOCATED IN AN ACCESSIBLE POSITION AT LEAST 6" AND NO GREATER THAN 12' BELOW THE MINIMUM OPERATIONAL WATER LEVEL AND BE FITTED WITH A SELF CLOSING, SELF LATCHING FITTING IN ACCORDANCE WITH IAPMO SPS 4. SKIMMER AND VACUUM FITTING DETAIL LADDER DETAIL N.T.S. CROSS BRACE RECOMMENDED LEVEL LADDER TREADS SHALL BE SLIP -RESISTANT POOL WALL - FLOOR REINF. AS PER STANDARD PLAN -- TO PUMP ' I- L E I-� 2 - #3 BARS BENT AS SHOWN EACH 1 112" DIA, 1 11 - - WAY AND LAPPED HYDROSTATIC RELIEF 18' WITH FLOOR PIPE BOTTOM 12" _ REINFORCEMENT. PERFORATED. (SEE (� MIN. 3' GENERAL NOTE 13) °D CLEARANCE = FROM EARTH 314'-1-1/2" I DRAIN ROCK 24" SQ ORO MAIN DRAIN DETAIL N.T.S. RESIDENTIAL GENERAL NOTES AND DETAILS CROWN POOLS, INC. CPC #1456979 3002 PHILLIPS HIGHWAY JACKSONVILLE, FL 32007 (904) 858-4300 NOT TO SCALE SHEET 1 OF 4 A 12' WHITE VINYL JOINT 8' - 11' STRIP (N/A / FORPAVER/� WATER LINE TILE, GLAZED, MIN. 4' CONCRETE DECK (OPTIONAL)1 1.i ] WITH SLIP RESISTANT TOPPING WATER FT THICKNESS ON COMPACTED GROUND WITH INCHES ALL ORGANIC MATERIAL 6 3.5 REMOVED. 4' THK. WITH FIBER b 8 MESH, 6' WITH #3 REBAR TYPICAL WALL RETURN, OR 5.0 VACUUM FITTING, WITH 3 EA 03 REBAR CONTINUOUS 18' WATER STOP FLANGE LAP SPLICES AS NECESSARY NOTE: GREATER WALL THICKNESS O OR LIGHT FIXTURE S 3' FOR AESTHETICS OR 1 NICHE MIN. R = 6 WHEN H = 3'-0' .` RADIUS INCREASES 6' FOR EACH V OF DEPTH < 5'-0' R - 2'40' WHEN H - 5'-0' F RADIUS INCREASES 1' FOR EACH 1' OF DEPTH > 5'-0' STD. REINF.: L (QUARTZ AGGREGATE PLASTER FINISH #3 REBAR @/ 10' O.C. B.W. MIN. r SHOTCRETE WALL COVER 3- (EARTH SIDE). 2- 1 6' MIN SHELL (POOL SIDE). REFER TO THICKNESS STRUCTURAL NOTE #1 FOR ALTERNATE SCHEDULE. — --_= TYPICAL POOL WALL SECTION SCALE: N. T. S. SPA WALL SCHEDULE DEPTH OF CONCRETE WATER FT THICKNESS INCHES 3,0 6 3.5 6 4.0 8 4.5 10 5.0 10 VERTICAL REINFORCEMENT #3 - 10 INCH CENTERS. NOTE: GREATER WALL THICKNESS O OR DOUBLE CURTAIN REINFORCEMENT MAY BE USED IF REQUIRED FOR AESTHETICS OR PLUMBING 2 - #3 BARS (OR 1 - #4 BAR) HORIZ. REIN. #3 BARS 8' I O.C. FOR FREE STANDING WALLS VERT, REINF. SEE SPA I WALL SCH. SPA DETAIL N.T.S. SEE SPA WALL SCH. m SEE STRUCTURAL NOTE 15 I — TYPICAL REINF. 10:0.C. E.W. FLOOR REINF. CONT FROM SPA TO POOL MIN. 15' LAP EITHER DIRECTION 2 - #3 EACH WAY Z N �lt i t LIGHT NICHE DETAIL N. T. S. 10' MIN DECK SLAB 3- MIN. (TYP.) EXPANSION JOINT VINYL �— DECK SLAB �� 1 Pa SEE STRUCTURAL NOTE 15 BOND BEAM REIN. 3-#3 BARS (TYP. FOR ALL BOND BEAMS) CANTILEVER DECK DETAIL N.T.S. EXPANSION JOINT 2 - #3 — BEND DOWN BOND BEAM BARS #3 BAR BEND AS SHOWN — — - ( SKIMMER DETAIL N.T.S. WATER ALTERNATE TROUGH 12 PLUMBING AT GRADE LOCATION —� AT GRADE WATER I OR ELEVATED TROUGH i OR I! SHEER DESCENT DETAIL N.T.S. ALTERNATE LOCATION OF BOND BEAM BAR (TYP) I b COPING DETAIL N.T.S. DECK A - MINIMAL BOND BEAM N.T.S. NOTE: MAYBE USED WITH SAND, GRAVEL, OR ROCK SOIL CONDITIONS ONLY. RESIDENTIAL STRUCTURAL DETAILS CROWN POOLS, INC. CPC #1456979 3002 PHILLIPS HIGHWAY JACKSONVILLE, FL 32007 (904) 858-4300 OWG. BY: MAC 3'0" MIN. (EDGE OF OUTLET) q: I 3'0" MIN. (EDGE OF OUTLET) SO- MIN. (EDGE OF OUTLET) OUTLETS IN PARALLEL TO ONE PUMP OUTLETS IN PARALLEL TO DUAL PARALLEL OUTLETS TO TWO PUMPS LIMPS IN PARALLEL NOTES: 1. DUAL OUTLETS SHALL BE SEPARATED BY MINI�OUTILS ET FROM OUTSIDE EDGE TO OUTSIDE EDGE OF OUTLET. 2. TEE ON THE SUCTION MANIFOLD SERVING THE SHALL BE LOCATED MIDWAY BETWEEN THE OUTLETS WITH FLOW OUT OF THE BRANCH OF THE TEE. 3. THE FLOW RATING OF EACH COVER/GRATE SHALL BE AT LEAST EQUAL TO THE SYSTEM'S MAXIMUM FLOW RATE. 4. OUTLETS MAY BE LOCATED ON SEPARATE PLANES IN LIEU OF THE 3'0" SEPARATION REQUIREMENT, I.E.ONE (1) ON THE BOTTOM AND ONE (1) ON THE VERTICAL WALL, OR ONE (1) EACH ON TWO (2) SEPAPyATE VERTICAL WALLS, DUAL SUCTION OUTLET ARRANGEMENTS 3'0" MIN. (EDGE OF OUTLET) OUTLETS IN PARALLFJ OUTLETS IN PARALLEL SYMMETRIC PIPING ECCENTRICALLY TAPPED PIPING OUTLETS IN PARALLEL LOOPED PIPING NOTES: 1. THE OUTERMOST OUTLETS SHALL BE SEPARATED BY MINIMUM 3 FEET FROM OUTSIDE EDGE TO OUTSIDE EDGE OF OUTLET. 2. TEE ON THE SUCTION MANIFOLD SERVING THE OUTLETS SHALL BE LOCATED MIDWAY BETWEEN TWO OF THE OUTLETS WITH FLOW OUT OF THE BRANCH OF THE TEE. 3. THE SUM OF THE FLOW RATINGS OF THE COVERSlGRATES SHALL BE AT LEAST TWICE THE SYSTEM'S MAXIMUM FLOW RATE. THREE. -OR -MORE SUCTION OUTLET ARRANGEMENTS NOTES: 1. ALL COVERS(GRATES SHALL COMPLY WITH ANSUASME Al 12.19.84ATEST,'SUCTION FITTINGS FOR USE IN SWIMMING POOLS. WADING POOLS. SPAS AND HOT TUBS.' RECOMMENDED: GRATES SHOULD BE INSTALLED WITH SUFFICIENT OPEN AREA TO ENSURE A MAXIMUM VELOCITY OF 1.5 FVS THROUGH THE GRATE(S). 2. SUCTION OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH NSUAPSP-7, LATEST THE FOLLOWING METHODS TO AVOID ENTRAPMENT ARE IN ACCORDANCE WITH ANSI/APSP-7: A) SURFACE SKIMMING OR OVERFLOW SYSTEMS THAT PROVIDE 100% OF THE REQUIRED SYSTEM FLOW: B) DUAL SUCTION OUTLET SYSTEMS; C) THREE -OR -MORE SUCTION OUTLET SYSTEMS; D) SINGLE UNBLOCKABLE SUCTION OUTLET SYSTEMS; E) SINGLE OUTLET SWIM JET SYSTEMS (TESTED AND LISTED AS CONFORMING TO ASME/ANSI Al 12.19.8); F) SINGLE OUTLET - ALTERNATIVE SYSTEMS (IN ACCO�DANCE WITH ANSIIASME Al 12.19.8-L4TEST AND ASTM F2387-04): G) GRAVITY FLOW TO A VENTED COLLECTOR TANK; H) OUTLET SUMPS IN SERIES; 1) OR OTHER MEANS THAT MEET THE INTENTS AND REQUIREMENTS OF ANSI/APSP-7 AND IS APPROVED BY THE AUTHORITY HAVING JURISDICTION. 3. BRANCH SUCTION PIPING (DEFINED AS THE PIPING SERVING THE SUCTION OUTLETS) SHALL BE SIZED TO ALLOW MAXIMUM VELOCITY OF SIX (6) FEET PER SECOND WHEN ONE OF A PAIR IS BLOCKED. ALL OTHER SUCTION PIPING SHALL BE SIZED TO ALLOW MAXIMUM VELOCITY OF EIGHT (8) FEET PER SECOND. 4. POOLS OR SPAS SHALL NOT BE OPERATED IF SUCTION OUTLET G �ATE IS MISSING. BROKEN, OR LOOSE. 5, SUCTION INLETS SHALL BE PLUMBED SUCH THAT WATER IS DRAWN THROUGH THEM SIMULTANEOUSLY THROUGH A COMMON LINE TO THE PUMP. 6. SUCTION OUTLET PORT MUST BE SAME DIAMETER OR LARGER THAN SUCTION PIPE EXITING OUTLET. 7. FIELD BUILT SUMPS SHALL BE CONSTRUCTED SUCH THAT THE OPENING OF THE SUCTION PIPE WILL BE NO CLOSER THAN 1.5 TIMES ITS INSIDE DIAMETER FROM THE BOTTOM OF THE COVER/GRATE OR SUCH THAT THE SUMP IS OF THE DESIGN SPECIFIED BY THE COVER/GRATE MANU JACTURER TO CONTROL FLOW THROUGH THE OPEN AREA OF THE COVER/GRATE CIRCULATION LINE TO LEAF CANISTER / RECIRCULATION PUMP NOTE: SEE NOTE 1 BELOW SINGLE UNBLOCKABLE CHANNEL OUTLET TO SINGLE PUMP SINGLE UNBLOCKABLE CHANNEL OUTLET TO TWO PUMPS ANY SHAPE LARGE UNBLOCKABLE OUTLET OF ANY SHAPE TO SINGLE PUMP NOTES: 1. SINGLE CHANNEL OUTLET: 3" OR GREATER IN WIDTH AND 31' OR GREATER IN LENGTH (APPLIES TO PERFORATED AREA). 2. SINGLE UNBLOCKABLE OUTLET: SHALL BE OF ANY SIZE AND SHAPE SUCH THAT A REPRESENTATION OF THE TORSO OF THE 99TH PERCENTILE ADULT MALE CANNOT SUFFICIENTLY BLOCK IT TO THE EXTENT THAT IT CREATES A BODY SUCTION ENTRAPMENT HAZARD. THE TORSO IS REPRESENTED AS A RECTANGLE 18"X 23" WITH CORNERS OF RADIUS 4". SINGLE UNBLOCKABLE SUCTION OUTLET ARRANGEMENTS 2" TEE 17 AIR GAP (MIN.) 1 MAXIMUM UNDERWATER LENGTH OF VENT PIPING: 30 FEET FROM TEE ON SUCTION PIPING TO AIR GAP SUCTION OUTLET DEBRIS OUTLET MOUNTED IN POOL FLOOR MINIMUM PIPE LENGTH 18" 1. ONE OF THE FOLLOWING OPTIONS IS REQUIRED BETWEEN THE DEBRIS SUCTION OUTLET AND THE PUMP: A) ONE (1) ADDITIONAL SUCTION OUTLET WITH A LISTED COVER/GRATE LOCATED A MINIMUM OF 18' FROM THE TEE IN THE SUCTION LINE TO THE PUMP(S); B) AN ENGINEERED VENT SYSTEM; C) A LISTED MANUFACTURED SAFETY VACUUM RELEASE SYSTEM. OUTLET SUMPS IN SERIES 2. 90- BEND (TYP. 1 VELOCITY = 6 FT 15 OF 2) SCH 40 SCH 80 SUCTION PIPE I MAX FLOW MAX FLOW DIAMETER (GPM) (GPM) 2- 63 55 2112' 90 79 3" 138 124 4- 238 215 6' 540 468 SCREEN VENT TO PROHIBIT INSECT ENTRY OR CLOGGING. LABEL VENT AS FOLLOWS: "POOL SAFETY DEVICE - DO NOT HANDLE' TO SUCTION PIPING \- 2" VENT PIPING VENT LINE DETAIL RESIDENTIAL SUCTION OUTLET NOTES AND DETAILS CROWN POOLS, INC. CPC #1456979 3002 PHILLIPS HIGHWAY JACKSONVILLE, FL 32007 (904) 858-4300 DWG. BY. MAC NOT TO SCALE SHEET 3 OF 4 APPROVED aY:.EL TRANSFORMER REQUIRED FOR LOW -VOLTAGE INSTALLATIONS ONLY INSIDE WALL BONDING CONDUCTOR. ol 01,0� REFER • NOTE #7 %�iiiiiiiiiiiiiiiiii 05 r, PUMP MOTOR I 1 I i 300 WATT 1 REFER TO UNDERWATER i NOTE 4 LIGHT R T 1 4444444 1 i 1 1 I i REFER TO NOTE #6 TYPICAL SWIMMING POOL BONDING GRID PLAN JUNCTION SPST TOG BOX TOGSWITCH 4' MIN. TIOISCONNECT 12 V TRANS. 3 #12 IN Y,• COND. PUMP- ' iNOTES: 1. ALL ELECTRICAL SHALL CONFORM WITH ART 680 NEC - LATEST 12V( 300W WITH LOW WATER 2. BOND ALL SHEATHED CABLES, RACEWAYS, METAL PIPING CUT-OFF W 1 H VAC W/ GFCI AND ALL FIXED METAL PARTS NOT SEPARATED BY PER NEC PERMANENT BARRIER, IF WITHIN 5 FT HORIZONTALLY FROM WATER, 12 F7 VERTICALLY OF MAX WATER LEVEL. ELECTRICAL DIAGRAM SERVICE PANEL NEUTRAL BAR /- T� GROUND GROUNND BMt NEUTRALBAR TRANSFO 7 3CONDUCTOR H -N -G POWER SUPPLY POOL LIGHT FLEXIBLE CORD GROUNDING TERMINAL #8 BOND TOI� ` #8 BOND TO STRUCTURAL STEEL GROUND BAR #8 80 IN STRUCTURAL CONTROL PANEL PVC C INOU1T STEEL TYPICAL GROUNDING SCHEMATIC LADDER. HAND RAIL, DIVING BOARD, ETC... ENERGY EFFICIENCY NOTES: 1. TIME SWITCHES SHALL BE INSTALLED TO CONTROL SWIMMING POOL HEATERS AND PUMPS THAT CAN AUTOMATICALLY TURN THE HEATERS AND PUMPS OFF AND ON ACCORDING TO A PRESET SCHEDULE. EXCEPTIONS; 1.a. WHERE PUBLIC HEALTH STANDARDS REQUIRE 24-HOUR PUMP OPERATION 1.b. WHERE PUMPS ARE REQUIRED TO OPERATE SOLAR- AND WASTE -HEAT RECOVERY POOL SYSTEMS 1.c. WHERE PUMPS ARE POWERED EXCLUSIVELY FROM ONSITE RENEWABLE GENERATION 2. HEATED SWIMMING POOLS AND INGROUND PERMANENTLY INSTALLED SPAS SHALL BE EQUIPPED WITH A VAPOR -RETARDANT COVER ON OR AT THE WATER SURFACE OR A LIQUID COVER OR OTHER MEANS PROVEN TO REDUCE HEAT LOSS. EXCEPTION: OUTDOOR POOLS DERIVING OVER 70% OF THE ENERGY FOR HEATING FROM A SITE -RECOVERED ENERGY OR SOLAR ENERGY SOURCE COMPUTED OVER AN OPERATING SEASON. 3, POOL FILTRATION PUMP MOTORS SHALL MEET THE FOLLOWING REQUIREMENTS: 3.a. POOL PUMP MOTORS SHALL NOT BE SKIT -PHASE. SHADED POLE OR CAPACITOR START INDUCTION RUN TYPES 3.b. POOL PUMPS AND POOL PUMP MOTORS WITH A TOTAL HORSEPOWER (HP) OF GREATER THAN OR EQUAL TO 1 HP SHALL HAVE THE CAPABILITY OF OPERATING AT TWO OR MORE SPEEDS. THE LOW SPEED SHALL HAVE A ROTATION RATE OF NO MORE THAN 4 OF THE MOTOR'S MAXIMUM ROTATION RATE. 3.c. POOL PUMPS MOTOR CONTROLS SHALL HAVE THE CAPABILITY OF OPERATING THE POOL PUMP AT A MINIMUM OF TWO SPEEDS. THE DEFAULT CIRCULATION SPEED SHALL BE THE RESIDENTIAL FILTRATION SPEED WITH A HIGHER SPEED OVERRIDE CAPABILITY FOR A TEMPORARY PERIOD NOT TO EXCEED ONE NORMAL CYCLE OR 24 HOURS, WHICHEVER IS LESS, EXCEPTION: SOLAR POOL HEATING SYSTEMS SHALL BE PERMITTED TO RUN AT HIGHER SPEEDS DURING PERIODS OF USABLE SOLAR HEAT GAIN. 4. HYDRAULIC SYSTEMS FOR NEW POOLS MUST BE DESIGNED IN ACCORDANCE WITH APSP-15, *AMERICAN NATIONAL STANDARD FOR RESIDENTIAL SWIMMING POOL AND SPA ENERGY EFFICIENCY. - POOL METAL CONDUITS REINFORCING OR PIPING SYSTEM, STEEL TO GROUND FAULT CIRCUIT INTI itRUPTER THEN TO POWER SOURCE WITH TRANSFORMER 4' MIN. JUNCTION BOX - RIGID, IMC OR NON METALLIC CONDUIT BRASS OR NON METALLIC CONDUIT OR APPROVED EQUIVALENT 300 WATT UNDERWATER LIGHTS SHALL BE NEC. APPROVED AND SHALL FEATURE STAINLESS STEEL FORMING SHELL WITH BRASS MOUNTING RING. SHELL SHALL HAVE A I- NPT CONDUIT WITH OPENING PACKING GLAND. LIGHT SHALL BE HOUSED IN A STAINLESS STEEL ENCAPSULATION BOLTED TO A CHROME PLATED FACE RING FOR COMPRESSING OF A 300- DOUBLE WALL SYNTHETIC GASKET. SS LIGHT FIXTURE 8 NICHE W/ COMPRESSION HUB & 300W.1 2V LAMP OR 120 VAC W/ GFCI PER NEC JUNCTION BOX (IF PUMP 98 AWG PRESSURE GROUND CONNECTOR TO COMMON BONDING WITH REINFORCING STEEL OR PLUMBING POOL LIGHT DETAIL POOL LIGHT HEATER CASE ELECTRICAL NOTES: 1. GROUND AND BOND ALL POOLS AND RELATED EQUIPMENT IN ACCORDANCE WITH NEC ARTICLES 250 AND 680. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR TO ENSURE THAT ALL METALLIC PARTS OF THE POOL STRUCTURE, INCLUDING THE POOL SHELL AND DECK REINFORCING BARS AND ALL OTHER METAL PARTS ARE BONDED PER NEC ARTICLE 250 AND 680. BOND TOGETHER REINFORCING BARS USING STEEL TIE WIRES. BOND ALL METAL PARTS TO POOL REINFORCING BARS USING #8 AWG COPPER WIRES. THESE METAL PARTS INCLUDE, BUT ARE NOT LIMITED TO LADDERS. RAILINGS, PIPING, CONDUIT. METAL DOOR FRAMES AND METAL PARTS WITHIN 5' OF INSIDE WALL OF POOL, CONNECTION SHALL BE EXOTHERMIC WELD. LISTED PRESSURE CONNECTORS OR CLAMPS AS APPLICABLE. GROUND STEEL COLUMNS (I.E. FOR TOWERS OR SLIDES) PER NEC ARTICLE 250 AND 680 AND NFPA 780. IF REINFORCING BARS ARE ENCAPSULATED WITH A NON CONDUCTIVE COMPOUND, CONTACT ENGINEER BEFORE PROCEEDING. 2. THIS ELECTRICAL INSTALLATION SHALL MEET ALL REQUIREMENTS OF NEC ARTICLES 250 AND 680. IN ACCORDANCE WITH THIS, UNDERGROUND WIRING SHALL NOT BE PERMITTED UNDER THE POOL OR WITHIN 5' HORIZONTALLY FROM THE INSIDE WALL OF THE POOL UNLESS THIS WIRING IS NECESSARY TO SUPPLY POOL EQUIPMENT PERMITTED BY NEC ARTICLE 680. ALL RECEPTACLES SHALL BE LOCATED AT LEAST 10' FROM THE INSIDE WALL OF POOLS. ALL RECEPTACLES WITHIN 20 OF THE POOL SHALL HAVE GFCI PROTECTION. ADDITIONALLY, ALL UNDERWATER LIGHTING SHALL BE GFCI PROTECTED. MOUNTING HEIGHT FOR ANY LIGHT FIXTURES SUSPENDED OVER POOLS SHALL BE NOT LESS THAN 12' ABOVE MAXIMUM WATER LEVEL 3. IF APPLICABLE. PROVIDE #12 AWG CONDUCTORS AND GROUND FOR 12V UNDERWATER LIGHTING CIRCUITS LESS THAN 8' IN LENGTH. FOR 12V CIRCUITS 9 TO 15' IN LENGTH, PROVIDE #8 AWG CONDUCTORS AND GROUND. FOR 12V CIRCUITS GREATER THAN 15', BUT LESS THAN 25' IN LENGTH, PROVIDE #6 AWG CONDUCTORS AND #6 GROUND. NO 12V CIRCUIT SHALL BE MORE THAN 25' IN LENGTH. 4. OPTIONAL: ELECTRICAL CONTRACTOR SHALL INSTALL NO FEWER THAN ONE 125 -VOLT 15- OR 20 -AMPERE RECEPTACLE ON A GENERAL PURPOSE BRANCH CIRCUIT. RECEPTACLE SHALL BE LOCATED NOT LESS THAN 10 FT FROM AND NOT MORE THAN 20 FT. FROM THE INSIDE WALL OF THE POOL. THE RECEPTACLE SHALL BE LOCATED NOT MORE THAN 6 FT. 6 IN. ABOVE THE FLOOR, PLATFORM, OR GRADE LEVEL SERVING THE POOL. 5. RECIRCULATION PUMP SHALL BE ELECTRICALLY INTERLOCKED WITH CHEMICAL EQUIPMENT, IF APPLICABLE. 6, AN EQUIPOTENTIAL COMMON BONDING GRID IS REQUIRED FOR ALL PAVED WALKING SURFACES WITHIN THREE FEET OF THE INSIDE WALLS OF THE POOL AND/OR SPA FOR THE ENTIRE POOL PERIMETER. THE BONDING GRID MAY BE COMPOSED OF STEEL REINFORCING RODS (REBAR), OR #8 BARE, SOLID COPPER CONDUCTORS.6 X 6 X 10 WELDED WIRE FABRIC (MESH) IS ACCEPTABLE WHEN PROPERLY INSTALLED ON CHAIRS AND EACH SECTION IS CLAMPED WITH APPROPRIATE LISTED DEVICES AND/OR #8 SOLID COPPER JUMPERS. THE BONDING GRID MAY NOT BE INSTALLED DIRECTLY IN EARTH CONTACT OR WITHOUT PROPER COVER. THE INSTALLATION MUST BE IN ACCORDANCE WITH 680.26(C), NATIONAL ELECTRIC CODE (NEC - LATEST VERSION) AND FLORIDA BUILDING CODE (FBC - LATEST VERSION) W/ LATEST AMENDMENTS. 7. THE FOLLOWING IS AN ACCEPTABLE ALTERNATIVE TO THE BONDING GRID DEFINED IN NOTE 06, ABOVE: AN UNDERGROUND BONDING CONDUCTOR MADE OF A SINGLE #8 AWG BARE SOLID COPPER WIRE BURIED TO A MINIMUM DEPTH OF 4 INCHES TO B INCHES BELOW SUBGRADE AND 18 INCHES TO 24 INCHES FROM INSIDE WALL OF THE SWIMMING POOL DR SPA. THIS IS DEFINED A PERMISSIBLE ALTERNATIVE OR EQUIVALENT TO COMPLIANCE WITH S.680.26(C) OF THE NEC (2014). NFPA 20. ADOPTED BY REFERENCE WITHIN FBC. -'" RESIDENTIAL CONTROL PANEL ELECTRICAL NOTES o AND DETAILS `t • TYPICAL BONDING SCHEMATIC CROWN POOLS, INC. CPC #1456979 3002 PHILLIPS HIGHWAY JACKSONVILLE, FL 32007 (904) 858-4300 DWG, BY MAC NOT TO SCALE SHEET 4 OF 4 APPROVED BY. �E- NEW CALCULATION5 LOT=13624 5QFT NEW IMPERVIOUS ROOFED 5TRUCTURE5=81 O SQFT NEW IMPERVIOUS CONCRETE WALKWAY/DRIVEii2221 5QFT NEW PERVIOUS PAVERS -258 SQFT POOL COPING=48 5QFT POOL -291 5QFT NEW TOTAL IMPERVIOU5=6239 (45.7%) 16 SCALE .,'Ow I I I I - L I �- I 2 STORY WOOD FRAME RESIDENCE NO. 1721 - I I I I 1 I I 1 I I I � I �In wild Je.'k I � � I ^q �001- EQUIPMENT LOCATION17th rxrteltta.w 4�k I� 0 ^ ,mull sib felrc<around eon Mian! I_ X414 - \ N N(YD:. Bwsryw ra Icx.c A q'. 5 21- 1 11 VITRO, FI bAlii FFE . 21.9 GARAGEFFE.- T2-2 ra.xea -} _ xi.,ws'wondsna , w 14w _ r ALJ-' 4 1Z If __-- 5.5' .1' ---- x .2t.91 - NAvo w N-bn 1 EXISTING 2 STORY FRAME < I NM RESIDENCE No. 1719 aedd.g FFE = 21.91 ! dPa�kNUAUV61 ', 918 -_--. INAvp V .. v/ / r I t L r.• o 1 a9.a4, to «c _ ' 'I Nwm bad vl ped. I.IIa6'. m.ee NBW .ma4�I. D'I i I I s'1 I - R 1 i ® I I a 8 '�I 's�NlWAvo ' aksg0• j kl 11 - �" 1 d Ihuk • I h stn latme.mwd m.uon atm - - - - - __._. _ _I b c j RIF CCC � X �e - 4B'4ih willies . LL- _ liege, t �Xm e phase 1 !1aPt oN fig° I I tome I _ 2 STORY WOOD FRAME RESIDENCE NO. 1717 ! I ! � ! I New Site Plan n 1 r 1. 9 le 11' U 11' wmddot Legal Description Existing Lot Area Calculations Lot 211, North AtLnric Desch Unic N. 1 R c Ms Cnryo - N Re -i N Pb, 17,624 s4 fl Hak 15, Page 10 Of The Current Public Rrcnrdr Of M -I County. Florida, Together GxisOn I - With The Sood NI Feet OI 17th Start As t'.kned A.d Recsmled in peed I,uW 1312, it ngxrs R fed Sou m 2,611 sq R 19.16 % Pages Ir) And 178, And E ... i Those Land. Lf in6 Ea-dy Of The Eewion Co 1 E d 8 pervwu Lei IW 0°n i be rtrrlovrd .662 fq R 0% Ci« for Said Duval fimnty. Fx 0 g Impm p Y � 4'24 sq ft 16.31% LN L-1 I-,- E thing Impery add bowl ttxm 11 sq 0 0,13% E bti.g Tofal,ntpe uv __-.. _--.-__-.-_11,11 4,853 sgfl 35.62% 1 15-10119-25-NE.320 2 N ATLANTIC BEACH UNIT NO I New Lot Area Calculations J LOT' N.S 1/2 CL ST N THEREOF Id 13,624 sq R -- N N ImperriomR fed Stmcturcs BlOsq fl. 5.95% 1. --- Douudary Md Tp,y phis Survey. N Imperviou (concrme), waawayA Mvewrys 2,221 pft 16.3% Bexi t p Bi On A Line Franr The pcpan Of N-.1 R-uu.c- Monument No. New pervious 1516 Q 50% 258 N R 1.99% -81 AIi To No. 72 81 -AIB Ar Pei, Caribi Construction Cmml Line For Uuvdp aW' - 0 pp-, Ju y lisooty. Flnnda As 14rvndcd In Ma Norsk (:, P 7'i Throu ]2h 1 d I 21. - - - ---- wood Ix.kme frd o5a fibs aq R _ o n 1992. Dong 5(6°32'05•E N _._ 3 Mran High W.- 11, Ifased On Extended Poblhhcd Damm For T,de Station fin( g Twl lelrelamg 2.611 R 19 l 8]40291 lT-le-ill, Dcxh). New T-1 irtyiwa•iom 5,918 p R 47.65 % Mean High Water - 110 Muimum aibwabk Cot Coverage 'Oil Tide Rr gc 50'1 a. Seaw il High W Liue Ax [Xfimd Dy Ibdda Sumtn Chapin ftil 05,3 ((:)(A)2: UESIUN CRITERIA: 'Serino I High 1-n Mean.+ Thr Line Fomred By The Intmmiou Of The knits Building Classiflcation: Restderstial Shorn And The Elevation (N 150 Penrnt Of Thr Loral Mean Tidal Runge Above Local Buildng Type Type V C dlixtiun Mean High W tiler. Mhw F.kv. +(1.5 X Tidal Range )-5hwl URlesv otherwise noted. projm site....id...Ii... hell be the responsibility of the und-or con0ncmr. Examples of s«h items include, but .,lull ort be limited m. 2.1P + (I,S X 5'rn = q ]() (Nord 19 ) determination of grade ekvai drainage Ratum, eld specbl requirtmena aswcumd 5. Erosion Comroi lin. Is Eb i B..,,ds y (NS -,t d V� with FEMA flag hmnrd a dlm Di avmc. ^. Erosion Conmoi Lore Dosed On The State Mme Co Miner- Ar Recorded In Pb, the coniramor is rceponsible for the means end methods of conatrucrion. R is the Book J3, Pages 59, 59x, 396. ontnet0i sole responsibility to determine the procedure, sequence, and temporary ]. Bencb Mark Vend Is Naii In A Palm Adjacent To 1671 Beach Avenue. bmcingaminsme thr seferyofdie building and its componrnl pons during cons[rluTirm. Elrvauunw lJ.2d1 (N.g.v.J. 1929) 8. Ali Pip- In S tiiry Mwdwl-.4c 6' Re. The eon -ii shell verify ell conditions ¢rad dime^.,inns at the job site prior t9 Y. Elevatirm Uamm C.00vmed From Ns -d. 1929 T. N, -d, 1988 Using C.m- wittit ins work. 6.0.1. ITitum C-6- Farm.- (N.u.rd 19&0=(N.,,d. 1929-1.111) I he centnct9r 11 wppiy. I -ii, ..d build row Ure work all iti unchen, angles, PIft e.s, openings, sleeves, hangm, sleh depressions• ii other components as may be Ieq.i m. -hand xcomnwdam ether work. It if Ne ewnefs ard.'or contuelor'a rtaponeibilitY m.,.,blain a soils ex0lontion .seen. TM Engineer shall be notified if soil .,i encountered differ Rom the noted --' "-- - - ----- - - - --, asmmptiom. All requirements for site Preparation and soil compaction specif din the -1. r.1 Bull be followed unless more smiogent rcquiremrnls ore specified in .hese I Plan. Site Plan Key aocc OOOOOVOO pa D A -u,r O OO Pr.v P Ur. C vnmr ox C - wrn net ravrN!oncl. �zs Yp Pmx Eprex: c..sm I I 1 1 13 5-4 1¢s vz�Ro° ,es lel II Nf1C coon✓oyrru .nett � � Snst Msalxsw Har -, slope �1 ---------- W.- E--caxouQ.- 1 I les EnmNU Stnrrnrw Smr F.laranare ..rad � i 1 I _ Naw 0...s I IF - - Site Plan Notes r, 1. Th dr gi, b d h dry d p gr ph .....y made be B wngh farad e 5 yo INC fJ k 'ill a h BeJ nuary 25th 201]. S y1 M1 dtsh tM pW J( I i C ....... -bl'.h hFl I 1. tl ilding 1 Y d- . rhux'n tn u it. lass til tumdation wa11. se j 8 pan. Yb Is (or elLni ion 4 Parkmit dmumwns --h- to froi -les odumuc i a I- gard he,sn so bask of.tb.,micsnoted rwhensue. 1 Work rh - q Mfii,f, nacd g The Gerfel ( hall -F, ill property h m k -,k rcq--- -h,apemen dee A,i Ise h FL C.-, -k q p A p du .bill be' Ili d ith h 1h,nditU p T p S m I Sp n to, Hyl 8. L I d' d't d by i R fi All d's y toll J ly w publ hid, h ) fid th - d T n if1, run pi w e,isd, PI I ser drat will i I h T' b h dt II W hum puddhnp ii Wi mg I.. S I f - ill be p -d d M., proi line in best place (-i erosion 2 11, Hmiw un rc 2-m,, n d 15 1- in M•ighe gt2 Nn more than 12° -1611 m hs rid d verify wnh appropriate counsel. -- 13 1)o - scale I -bi U ly dimensions thous o° dmunnpd Ifdimensium -I--- - - .11 - on thr9m in a bu 1 ngcd before conanuittg with wctlon. Dodder I- - - - - - - shill vetBy a0 dun - A cundmum rz,loburc �r QI O ler AO.1 h p--1 tatimu A N- 11 , tab r.e � O ! W Coprrigh Y B Srxr 8hA U Asr« x lot All rhrs ed The rdes,gn conc<pns g Pc l h p6 perry dSr hl Sanford Ur �W doavmema lurllrnMh p d disclmM rholeeia a uy iarm wild au. cbc r f Starr Sanford Ikvgn Aav^<iarea, Inc. IM nae ode IfnoniWehu. dF'he curreci drmrnxi h Sy Seaford Uesyu A I Coetrxtor .d cand hm of theJrmeoviva. wwN. Mie Ce-STRUe ON DRAWINGS Project #: 16012 Date: 1/31/18 Revised: A1.2 POOL AREA: 291 SQ FT POOL PERIMETER: 69 FT G' WATER DEPTH (5" OF COPING (MATERIAL TBD) m 18" X 14'-6"X 16" W/D BENCH SEA / OVERVIEW 3'-G" WATER DEPTH 30" WATER DEPTH X 5'-711 TANNING LEDGE 3002 Phillips N14wa4 Jacksonville, F L 32207 ( 904) 858-4300 www,crnmPoo154c,com �A�- PPOJECT INPOPNlA110N MAING TITLE: OvMTw Pn0 CCT: ^A,LAIY 1719 GEALN AVE ATLANTIC DWH FI 5&ET: I OF 2 5C&E: /T\ F—i �J6,18 MAWFYI M CA5 — — — — — - 20'-411-----L-- d Ln I I � IT 311 -f 4'-G" — 18" WATER DEPTH 14 I Ln 8" W/D planting bed at grade 3'-G" WATER DEPTH 30" WATER DEPTH X 5'-711 TANNING LEDGE 3002 Phillips N14wa4 Jacksonville, F L 32207 ( 904) 858-4300 www,crnmPoo154c,com �A�- PPOJECT INPOPNlA110N MAING TITLE: OvMTw Pn0 CCT: ^A,LAIY 1719 GEALN AVE ATLANTIC DWH FI 5&ET: I OF 2 5C&E: DA11; �J6,18 MAWFYI M CA5