1644 MARITIME OAK DR - NEW HOME PERMIT ( Si-‘
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
.'2.013 c) INSPECTION PHONE LINE 247-5814
RESIDENTIAL - NEW SINGLE FAMILY RESIDENCE
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
PERMIT INFORMATION:
PERMIT NO: RES18-0273
Description:
Estimated Value: 407807.7
Issue Date: 8/20/2018
Expiration Date: 2/16/2019
PROPERTY ADDRESS:
Address: 1644 MARITIME OAK DR
RE Number: 169505 1935
PROPERTY OWNER:
Name: TOLL FL VI LIMITED PARTNERSHIP
Address: 250 GIBRALTAR RD
HORSHAM, PA 19044
GENERAL CONTRACTOR INFORMATION:
Name:
Address:
Phone:
Name:
Address:
Phone:
PERMIT INFORMATION:
Please see attached conditions of approval.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB
SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY
BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions
applicable to this property that may be found in the public records of this county, and there may
be additional permits required from other governmental entities such as water management
districts, state agencies, or federal agencies.
* A notice of Commencement is only required for work exceeding an estimated value of
$2,500. For HVAC work, a Notice of Commencement is only required when HVAC work
exceeds and estimated value of$7,500.
City of Atlantic Beach
PUBUC UTILITIES DEPARTMENT
1200 Sandpiper Lane
Atlantic Beach, FL 32233
(904)247-5834
NEW WATER/ SEWER TAP REQUEST
Date &- /0 - / $ Project Address Ho �(t( i'Vl►'ItZ l I i t'-4 E CA
Number of Units ( Commercial Residential v/ Multi-Family
41
New Water Tap(s) & Meter(s) Meter Size(s) —3/ti
i
New Irrigation Meter V Upgrade Existing Meter from to (size)
New Reclaim Water Meter VSize Sly , New Connection to City Sewer
Applicant Name
Applicant Address
City State Zip
Phone Cell
Email
Applicant Signature
CITY STAFF USE ONLY
Application it 10E5 I — 0
Water System Development Charge $ 1 �/
Sewer System Development Charge $ , O 5C), CSU
Water Meter Only $ / 8 S (JO
Reclaim Meter Only $ /N S, Uv
Water Meter Tap $
Sewer Tap $
Cross Connection $ 5o, 00
Other $
TOTAL $ S/ t!O / OC") (Notes)
APPROVED Kayle Moore, P.E. Date 1•lt7-S
Public Utilities Director or Authorized Signature
ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED
Sy>>y;y„, City of Atlantic Beach APPLICATION NUMBER
CJs rA Building Department (To be assigned by the Building Department.)
• 800 Seminole Road Q est —o 2-1 3
Atlantic Beach, Florida 32233-5445 ,
-` � Phone(904)247-5826 • Fax(904)24- 50 g 2015 Date routed:
,0109 E-mail: building-dept@coab.us
web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
•Property Address: 1.CQ 14 4 or("�t me._ Otk De•artment review required Yes No
---^ i:uildin•
Applicant: C 6 it ' rcS 'lanniny &Zonin
S Tree Administrator
Project: F � g.--ibi_i .. ,blic Utilitie
Public Safety
Fire Services
Review fee $ 50. Glp Dept Signature ..)
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept.of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APP CATION STATUS
Reviewing Department First Review: Approved. ❑Denied. ['Not applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING Reviewed by: ��'"'” Date: g—10 —f$
TREE ADMIN. Second Review: I 'Approved as revise - ❑Denied. I INot applicable
PU:;.' WORKS Comments:
' BLI UTILI S
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ['Approved as revised. ['Denied. ['Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
(iLJ
City of Atlantic Beach APPLICATION NUMBER
4. a Building Department (To be assigned by the Building Department.)
800 Seminole Road g sig-/o 2-13
.:
!� �r Atlantic Beach, Florida 32233-5445 �J
/ Phone(904)247-5826 • Fax(904)247 584 (r +'
/ Date routed: fi�;�t�? E-mail:Email: building-dept@coab.us ��. 3.
City web-site: http://www.coab.us
1.
APPLICATION REVIEW AND TRACKING FORM
Property Address: ko4 10.1(11 e_ Gil De artment review required Yes No
uildin
Applicant: [ 6 It eBraS tanning &Zonin
Tree Administrator
Project: S F ublic r
-alio Utilitie
' Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: 1'Approved. ❑Denied. ❑Not applicable
(Circle one.) Comments:
BUILDING
e
PLANNING &ZONING Reviewed b Date: --/-4
TREE ADMIN. Second Review: ❑Approved as revised. Denied. ❑Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ['Approved as revised. ['Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
01.:L.1/26 City of Atlantic Beach APPLICATION NUMBER
•
Building Department (To be assigned by the Building Department.)
800 Seminole Road o e-�J r
r? Atlantic Beach, Florida 32233-5445 11. 1 g—02-13
Air Phone(904)247-5826 • Fax(904)247-5845
J;il�r E-mail: building-dept@coab.us Date routed:
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: lioqg m aif 4 (/\ ak De•artment review required Yes No
.uildin•
Applicant: 4I rbS 'lanninng &ZonlrierN
Tree Administrator
Project: S F ublic or
ublic Utilitie
Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept.of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: ❑Approved. Denied. Not applicable
(Circle one.) Comments: A /
BUILDING
C GC cf Cn
PLANNING & ZONING
Reviewed by: i%� �� Date: 13- 12
-
TREE ADMIN. Second Review: Approved as revised. riDenied. Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: Approved as revised. ❑Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
0
REVOCABLE ENCROACHMENT AGREEMENT
REVOCABLE ENCROACHMENT AGREEMENT by the City of Atlantic Beach,Florida,a municipal corporation
organized and existing under the laws of the State of Florida,hereinafter referred to as"CITY"and
TOLL FL VI,LP of Atlantic Beach,Florida,hereinafter
referred to as"USER".
WITNESSETH:
That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the
property for the purpose as described in the City of Atlantic Beach.
This work is generally described as Pavers in the Right-of-Way for the driveway.
Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted remains subject to
relocation or removal on thirty(30) days' notice by CITY to USER, said notice to USER shall be given by certified mail,
return receipt requested,to the following address 1644 Maritime Oak Dr ' Parcel#67-132 08-2S-29E .
• In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter
upon the above described easement or property of the CITY,the USER shall replace at the USER's sole expense,
any and all material necessarily displaced during the action of maintaining,repairing,operating,replacing or adding
to of the utilities and facilities of the CITY or franchise utility provider.
• The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes, Land
Development Code and all other land use and code requirements of the CITY,including City Code Section 19-7(h)
which states "Driveways that cross sidewalks: City sidewalks may not be replaced with other materials, but must
be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks."
• The USER,prior to making any changes from the approved plans and/or method,must obtain written approval from
the City of Atlantic Beach Public Works Department,for said change within 30 days after the day of completion.
• This permit shall inure to the benefit of,and be binding upon,the USER and their respective successors and assigns.
• USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or
specifications,to include utilities locate requirements and use limitations/requirements of easements, public right-
of-ways and other pub 'c land. USER further agrees that the CITY and its officers and employees shall be saved
harmless by the US•* 'from any of the work herein under the terms of this permit and that all of said liabilities are
hereby assumed r ,•• USER. C(48`Q
/ Date `S l v
Property Owner/• •ent i ed in presence of Notary Public)
STATE OF FLORIDA,COUNTY OF 1)UVAL5TJ0►+iVS
The foregoing instrument was acknowledged this %5 day of JiA.M_ ,2015 ,
by STEVE NEIZTEN ,who personally appeared before me and
(printed name of Signer)
acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it.
Signatpiotary Public, State of Florida
/ Department Approval:
Personally Known
Produced Identification(Type) •
Scott illiams, Public or Director/
doff► Notary Public State of Florida Kayle Moore,Public Utilities Director
H:\Master Forms •ONit es !#oWil �ncroa 'ment Agreement 2.5.18.docx
Revision Date:2/' If
` My Commission GG 126089
je Expires 09/18/2021
„rr_r,.
°`V RIGHT-OF-WAY/ EASEMENT PERMIT
Permit#Issued by the City of Atlantic Beach R E S I g -02'13
PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES
Job Address 1727Atlantic Beach Drive ( 1644 ?) Phone 904-595-5243
Permittee Steven Merten Email aregnier(a)tollbrothers.com
Requesting Permission to Construct Pavers in the Right of Way for the driveway
Location(Reference to Cross-Street) Coastal Oak Lane&Maritime Oak Drive -06884 ATLANTIC BEACH COUNTRY CLUB UNIT 02
• Permittee declares that prior to filing this application they have ascertained the location of all existing utilities,
both aerial and underground and the accurate locations are shown on the sketches.
• Whenever necessary for the construction,repair,improvement,maintenance, safe and efficient operation,
alteration or relocation of all,or any portion of said street or easement as determined by the Director of Public
Works,any or all said poles,wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall
be immediately removed from said street or easement or reset or relocated hereon as required by the Director of
Public Works and at the expense of the Permittee unless reimbursement is authorized.
• All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed
under the supervision of Matt Olive (Project Superintendent)
located at 237 9th Avenue North,Suite 4,Jacksonville Beach,FL 32250
• All materials and equipment shall be subject to inspection by the Director of Public Works.
• All city property shall be restored to its original condition as far as practical, in keeping with City specifications
and the manner satisfactory to the City.
• A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part
of this permit. Calculations showing any increase in impervious area on owner's lot or in the City
right-of-way are to be included with this application.
• The permittee shall commence actual construction in good faith within days. If the beginning date is more
than 60 days from date of permit approval then permittee must review the permit with the Director of Public
Works to make sure no changes have occurred in the area that would affect the permitted construction.
• It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's
right,title and interest in the land to be entered upon and used by the holder, and the holder will,at all times,
assume all risk of and indemnify, defend and save harmless the City of Atlantic Beach from and against any and
all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of
the aforesaid rights . 8 privileges.
• The Director of • 'Pu Works shall be notified twenty-four(24)hours prior to starting work and again
immediately upo Pom.letion. t
Date G `! f
Permittee: Steven R�� 47-n,,o ivision President,TOLLFL VI,LP(signed in presence of Notary Public)
STATE OF FLORIDA,C•UNTY OF SAINT JOHNS
The foregoing instrument was acknowledged this (S day of itA)-‘9.._ ,20 1g ,
J
by I"evt)..'I-,J&/12 ,who personally appeared before me and
(printed name of Permittee)
acknowledge at he/ he signed the instrument voluntarily for the purpose expressed in it.
Personally Known
Signature of Public, • - . •-'•• Produced Identification(Type)
APGIr\ Notary Public State of Florida
Melissa Sue Lieberman
., - My Commission GG 128088
..0— Expires 09/18/2021
0•:virirCity of Atlantic Beach APPLICATION NUMBER
jsOirjlri Building Department (To be assigned by the Building Department.)
800 Seminole Road p-
Atlantic Beach, Florida 32233-5445 0
Phone(904)247-5826 • Fax(904)247-5845 —7 /
)- E-mail: building-dept@coab.us Date routed: t/ ( _
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: t q (4 m art k ML Ck De•artment review required Yes No
�.� d:uildin.
Applicant: ( cdt 'T 1 *tanning &Zonis
Tree Administrator
Project: S F
•ublic Utilitie-
Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
y
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St. Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco _
Other:
APPLI TION STATUS
Reviewing Department First Review: Approved. ❑Denied. [Not applicable
(Circle one.) Comments:
(—BUILDING
PLANNING & ZONING ^ S• 0-1
Reviewed by: Date:
TREE ADMIN. Second Review: A roved as revised. Denie Notapplicable
❑ PP ❑ ❑
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
OFFICE CORY.
Building Permit Application Updated 12/8/17
City of Atlantic Beach
800 Seminole Road,Atlantic Beach,FL 32233
Phone:(904)247-5826 Fax:(904)247-5845 ���� � ����
Job Address: 1644 Maritime Oak Dr Permit Number
Legal Description Lot 128 Atlantic Beach Country Club Unit 2, Parcel #67-52 16-25-29E RE# 169505-1935
Valuation of Work(Replacement Cost)$366615 Heated/Cooled SF 3218 Non-Heated/Cooled 906
• Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Window/Door
• Use of existing/proposed structure(s)(Circle one): Commercial Residential
• If an existing structure, is a fire sprinkler system installed?(Circle one): Yes No N/A
• Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal
Describe in detail the type of work to be performed:
New home construction
Florida Product Approval#see attached for multiple products use product approval form
Property Owner Information
Name: Toll FL VI Limited Partnership Address: 160 Cape May Avenue
City Ponte Vedra State FL Zip 32081 Phone 904-217-0739
E-Mail aregnier@tollbrothers.com
Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Toll FL VI, LP
Contractor Information
Name of Company: Toll Bros., Inc Qualifying Agent: Steven R. Merten
Address 160 Cape May Avenue City Ponte Vedra State FL Zip 32081
Office Phone 904-595-5243 Job Site/Contact Number 904-595-5243
State Certification/Registration# CGC1510225 E-Mail aregnier@tollbrothers.com
Architect Name&Phone# Toll Architecture(407)248-5800
Engineer's Name& Phone# Lou Pontigo&Associates(904)242-0908
Workers Compensation Policy#MWC30267702/Expries 9/1/2018
Exempt/Insurer/Lease Employees/Expiration Date
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this
permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and
there may be additional permits required from other governmental entities such as water management districts,state agencies,or
federal agencies.
OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING ONSULT WITH YOUR LENDER OR AN ATTORi EY BEFORE
RECORDING YOUR NJc ' CE OF COMMENCEMENT.
/ //
(Si:natur- • 'owner or Agent) (Si:-.ture of Contractor)
(including contractor) _
Signed and sworn to(or affirmed) before me this \'S day of Signed and sworn to(or affirmed)before me this IS day of
J U,hQ , 401g ,/bey f4 4A Hale!1-141 .1(01k. , (:)0)% , by
-11'
Signature of Notary) t_ nature of Notary)
Personally Known OR [ rsonally Known OR
[ ]Produced Identificatio ,.ss 044. Notary Public State of Florida [ ]Produced Identification 0$5 Notary Public State of Florida
Type of Identification: Melissa Sue Lieberman Melissa Sue Lieberman
yp Type of Identification:
a M Commission GG 11blY65
4
My . 'die Expires 09/18/2021
'�aR ' Expires 09/18/2021 Of P.
OFFICE COPY
PERMITTED BUILDING DATA
DO NOT WRITE BELOW — OFFICE USE ONLY
Applicable Codes: 6th Edition (2017) Florida Building Code
DEVELOPMENT SIZE:
Habitable Space (ft') .'j/S' Non-Habitable Space (ft")
LAND INFORMATION:
Zoning District A 6(6-
Flood
(GFlood Zone )C
Minimum FFE /2, 3pr f 1r9pGs, = / 3.601
BUILDING INFORMATION:
Construction Type
Occupancy Group
Number of Stories
Max Occupancy Load
Fire Sprinklers Required
CONDITIONS/ COMMENTS:
Rev. 2.7.2018
OFFICE COPY
PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA
Project Name: Toll Brothers,Inc. Permit# Gz&S it -U J 7 3
Project Address: 1644 Maritime Oak Drive Lot 128
As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s)
for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact
your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide
product approval may be obtained at:www.floridabuildin$.org.
Category/Subcategory Manufacturer Product Description Limitation of Use State# Local#
A. EXTERIOR DOORS
1. Swinging Masonite Wood Edge,Steel N/A Double-FL8228.6
Single-FL6506.4
Simpson Door Company Wood Door FL 14487.1
Therma-Tru Fiberglass/Wood Door N/A FL 5262.3
2. Sliding PGT 2500 Aluminum Slide Glass +25/-25 FL 251
3. Sectional +43.2/-49.6 8 ft FL 9174.12
Wayne Dalton Section Ext.Door +39.2/-43.7 16ft FL 9174.15
4.Roll up
5.Automatic
6. Other
B. WINDOWS
1. Single Hung PGT 5400 Vinyl Single Window +50/-50 FL 1435
2. Horizontal slider PGT 5400 Vinyl Hor.Window +50/-50 FL 1844
3. Casement
4.Double hung
5.Fixed PGT 5400 Vinyl Fixed Window +50/-50 FL 5012
6.Awning
7. Pass-through
8.Projected
9.Mullion PGT Alum/Vinyl Mullions N/A FL 261
10.Wind Breaker
11.Store Front/Mitred Glass Kawneer Glass Windows Mitred Glass Windows +30/-30 FL 10008.1
12. Glass Block US Block/Hy-Lite Glass Block Window 70 PSF FL 185.12
Category/Subcategory Manufacturer Product Description Limitation of Use State# OF Lol cF co r Y
C.PANEL WALL
1. Siding James Hardie Building Products,Inc. Lap Siding and Shingle Panels N/A FL 13192.2; 13192.4
James Hardie Building Products,Inc. Lap Siding and Shingles N/A FL 10477.1
FL 12098.3; 12098.1;
Nichiha Corp. Lap Siding and Shingles N/A 12875.1
2.Soffits/Ceilings James Hardie Building Products,Inc. Soffit Panels N/A FL 13265.1
Nichiha Corp. Soffit Panels N/A FL 12098.4
3.EIFS
4.Storefronts hawneer Glass Windows Mitred Glass +30/-30 FL 10008.1
5.Curtain walls
6.Wall louvers
7.Glass block
8.Membrane
9.Greenhouse
10.Synthetic Stucco
11.Other
D. ROOFING PRODUCTS
1.Asphalt shingles GAF Corp. Timberline 30 year Arch Shingles N/A FL 10124.1
2.Underlayments Woodland Industries,Inc. Felt N/A FL 1814.12
Boral Roofing Roof Underlayment N/A FL 14317.1
3.Roofing fastners
4.Nonstructural metal roof Millennium Metals,Inc. Metal Roofing-M seam N/A FL 5211.3 R6
5.Built-up roofing
6.Modified bitumen
7.Single ply roofing
8.Roofing tiles
9.Roofing insulation
10. Waterproofing
11.Wood shingles/stakes Watkins Sawmill LTD. Wood Shingles and Shake N/A FL 13714.1
12.Roofing slate
13.Liquid applied roofing
14.Cement-adhesive coats
15.Roof tile adhesive
16.Spray applied polyurethane
roof
17.Other Pli-Deck Walking deck membrane N/A FL 12407.1
Category/Subcategory Manufacturer Product Description Limitation of Use Stat®F F I CEZO PY
E. SHUTTERS
1.Accordion
2.Bahama
3.Storm panels Town and Country Industries Storm shutters N/A FL 11963
4.Colonial
5.Roll-up
6.Equipment
7.Other
F. STRUCTURAL
COMPONENTS
1.Wood connector/anchor Simpson Strong Tie Per engineering
2.Truss plates Alpine Engineered Truss plate conn. Per engineering
3.Engineered lumber Georgia Pacific Eng.Lumber FL 2023.1
4.Railing
5.Coolers-freezers
6.Concrete admixtures
7.Material
8.Insulation forms
9.Plastics
10.Deck-roof
11.Wall
12. Sheds
13.Other
G. SKYLIGHTS
1.Skylight Sun Tek FGC Skylite FL 2442
2.Other
H.NEW EXTERIOR
ENVELOPE PRODUCTS
1 7/16"Zip Wall-Structural 1 OSB(roof and vaI I): manLIfacturered by Huber Engineered Woods
2
In addition to completing the above list of manufacturers,product description and State approval number for the products used on this project,the
Contractor shall maintain on the job site and available to the Inspector,a legible copy of each manufacturer's printed specifications and installation
instructions along with this Product Approval Sheet.
I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the o
CYFFICE COPY
listed in this document must be approved by the Building Official.
Audrey Regnier 614.e_ltfr41007_,.
(Contractor Name) (Print Name) (Signature)
Company Name: Toll Brothers,Inc.
Mailing Address: 160 Cape May Avenue
City: Ponte Vedra State: FL Zip Code: 32081
Telephone Number: 904 217-0739 Fax Number:
Cell Phone Number: 904-405-8969 Email Address: aregnier@tollbrothers.com
JLQ o -P Flo c (do U1-Iw-IUL. LUI Y
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Terrano 3218 Left E Builder Name: Toll Brothers
Street: Lot 128 Atlantic Beach CC Permit Office: Duval
City,State,Zip: Atlantic Beach,FL, Permit Number:
Owner: Toll Brothers Jurisdiction: 261300
Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2)
•
1. New construction or existing New(From Plans) 9. Wall Types(3810.7 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 3605.70 ft2
b. Frame-Wood,Adjacent R=13.0 205.00 ft2
3. Number of units, if multiple family 1 c.N/A - R= ft2
4. Number of Bedrooms 4 d. N/A R= :ft2
5. Is this a worst case? No 10.Ceiling Types (1672.0 sqft.) Insulation Area
a.Under Attic(Vented) R=38.0 1446.00 ft2
6. Conditioned floor area above grade(ft2) 3218 b. Under Attic(Vented) : R=19.0 . 226.00 ft2 •
Conditioned floor area below grade(ft2) 0 c. N/A R= ft2
' 11.Ducts / R ft2
7. Windows(511.6 sqft.) Description Area a.Sup:Attic, Ret:Attic,AH:2nd.Floor. • 6 453.
a. U-Factor: Dbl, U=0.34 511.61 ft2 '
SHGC: SHGC=0.27
b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 60.0 SEER:14.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ' ft2 a.Electric Heat Pump • 60.0 HSPF:8.20
.SHGC:
Area Weighted Average Overhang Depth: 4.514 ft.
Area Weighted Average SHGC: 0.270 14. Hot water systems
a.Natural Gas Tankless Cap:1 gallons
8. FloorTypes (3218.0 sqft.) Insulation Area EF:0.800
a. Slab-On-Grade Edge Insulation R=0.0 1771.00 ft2 b. Conservation features k ,
b.Floor Over Other Space R=0.0 1293.00 ft2 None ,
c. other(see details) R= 154.00 ft2 15.Credits Pstat
Total Proposed Modified Loads: 74.36 PASS Glass/Floor Area: 0.159 tp�'"M.7 S
Total Baseline Loads: 90.27
iFu.• ili
I herebycertifythat theplans and specifications covered byReview of theplans and t `` THE Sri`''
P ir. ov.... - t.?fi'r`s'N.
this calculation are in compliance with the Florida Energy specifications covered by this 3 �,.;� . Off'+,
Code. calculation indicates compliance v„jt f '�:,�
�,v . �,� with the Florida Energy Code..00: lnrts .f,6,;:::;::;:::,-;,":‘;,,�:• i.
PREPARED BY' '�� -C 'e (icv t � Before construction is completed ;./..1 ; .:._.1.....,
DATE: d7- 'Z- �/8 this building will be inspected for •,, ofill_t /
compliance with Section 553.908 * •.. .�` /* I
Florida Statutes. �'•• 01' '', I
'1, ,...„>•''f. , •
with the Florida Energy Code. 4 4 ',„..0./)w13 �+'''
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE: k'I •ad 0
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
7/2/2018 6:01 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
OFFICE COPY
\\CBUCK EnQIneerInQ
Speclatt-y Structural Engineering CBUCK,Inc. Certificate of Authorization#8064
Evaluation Report
"M-Seam"
Metal Roof Assembly
Manufacturer:
Millennium Metals, Inc.
10200 Eastport Road
Jacksonville, FL 32218
(877) 358-7663
for
Florida Product Approval
# FL 5211.3 R6
Florida Building Code 5th Edition (2014)
Per Rule 61G20-3
Method: 1 - D
Category: Roofing
Sub - Category: Metal Roofing
Product: "M-Seam"
Material: Steel
Panel Thickness: 26 gauge, (Minimum)
Panel Width: 16"
Support: Wood Deck
Digitally signed by James L.Buckner,P.E.
Electronically signed and sealed documents
shall comply with the provisions of FAC Rule
Prepared by: 61G15-23. \11111
James L. Buckner, P.E., SECS ��`� �5.�.•B��k�;''
Florida Professional Engineer # 31242 �P.•' \CENSE'••,F,p';,
Florida Evaluation ANE ID: 1916 _ •
No 31242 _
_ .
* _
Project Manager: Youry Demosthenes : W
Report No. 15-104-M-S6W-ER �0STATE OF ZU�
(Revises 12-117-M-S6W-ER) .s •.cLORIDP.•''
Date: 7/ 1/ 15 /'/S/ONA`� ?\\��
Contents:
Evaluation Report Pages 1—7Fm
CBUCK, Inc. 2015.07.01 11:03:27-04'00'
1399 N. Killian Drive,Suite 4,West Palm Beach,Florida 33403
Phone:(561)491-9927• Email:cbuck@cbuckinc.net• Website:www.cbuckinc.net
FL#: FL 5211.3-R6
Date: 7/ 1/ 15
\CBLICK Engineering Report No.: 15-104-M-S6W-ER
Page 2 of 7
Specialty Structural Engineering CBUCK,Inc. Certificate of Authorization#8064
Manufacturer: Millennium Metals, Inc.
Product Name: "M-Seam"
Product Category: Roofing
Product Sub-Category Metal Roofing
Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d)
Product/System "M-Seam"
Description: 26 gauge Minimum, Steel roof panel mechanically attached to Plywood Deck with
screws.
Product Assembly as Refer to Page 4 of this report for product assembly components/materials &
Evaluated: standards:
1. Roof Panel
2. Fasteners
3. Underlayment
4. Insulation (Optional)
Support: Type:
Wood Deck
(Design of support and its attachment to support framing is outside the scope of this
evaluation.)
Description:
• 15/32 (min.) or 19/32" or greater plywood,
• or Wood plank (min. specific gravity of 0.42)
Slope: Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2,
applicable code sections and in accordance with manufacturer's
recommendations.
Performance: Wind Uplift Resistance:
• Design Uplift Pressure: Refer to Table "A"
(Refer to "Table A" attachment details herein)
FL#: FL 5211.3-R6
Date: 7/ 1/ 15
F� ' `,b�"` Report No.: 15 104 M S6W ER
.:3 , c=riotricrlrinc) Page 3of7
Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064
Jr-I-I E COPY
Performance Standards: The product described herein has demonstrated compliance with:
• U L580-06—Test for Uplift Resistance of Roof Assemblies
• UL 1897-04—Uplift test for roof covering systems
Standards Equivalency: • The UL 580-94 standard version used to test the evaluated product assembly
is equivalent to UL580-06 standard version adopted by the Florida Building
Code 5th Edition (2014).
• The UL 1897-98 standard version used to test the evaluated product
assembly is equivalent to UL1897-04 standard version adopted by the Florida
Building Code 5th Edition (2014).
Code Compliance: The product described herein has demonstrated compliance with Florida Building
Code 5th Edition (2014), Section 1504.3.2.
Evaluation Report This product evaluation is limited to compliance with the structural requirements of
Scope: the Florida Building Code, as related to the scope section to Florida Product Approval
Rule 61G20-3.001.
Limitations and • Scope of"Limitations and Conditions of Use" for this evaluation:
Conditions of Use: This evaluation report for "Optional Statewide Approval" contains technical
documentation, specifications and installation method(s) which include
"Limitations and Conditions of Use" throughout the report in accordance with
Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is
the authority to approve products under "Optional Statewide Approval".
• Option for application outside "Limitations and Conditions of Use"
Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific
approval by the local authorities having jurisdiction in accordance with the
alternate methods and materials authorized in the Code". Any modification of
the product as evaluated in this report and approved by the Florida Building
Commission is outside the scope of this evaluation and will be the responsibility
of others.
• Design of support system is outside the scope of this report.
• Fire Classification is outside the scope of Rule 61G20-3, and is therefore not
included in this evaluation.
• This evaluation report does not evaluate the use of this product for use in the
High Velocity Hurricane Zone code section. (Dade & Broward Counties)
Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.005 (3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity through Keystone Certifications, Inc. (FBC Organization #: QUA
1824).
FL#: FL 5211.3-R6
Date: 7/ 1/ 15
r"`""" a "Lj morzg. R;rt No.: 15-104-M-S6W-ER
.a.
. 4 of 7
Specialh.j Structural Engineering CBUCK, Inc.Certificate of Authorization#8064
tars ri GE c ,-
Qp .
Components/Materials Roof Panel: "M-Seam"
(by Manufacturer): Material: Steel
Thickness: 26 gauge Minimum
Panel Width: 16" (max.) Coverage
Rib Height: 1"
Yield Strength: 40 ksi min.
Corrosion Resistance: In compliance with FBC Section 1507.4.3:
• ASTM A792 coated, or
• ASTM A653 G90 galvanized steel
Fastener:
Type: Pancake-Head Wood Screw
Size : #10 x 1"
Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4
Standard: Per ANSI/ASME B18.6.4
Components/Materials Underlayment:
(by Others): Material and application shall be in compliance with FBC Section 1507.4.5.1 and
1507.4.5.2, applicable codes and in accordance with manufacturer's
recommendations.
Insulation (Optional):
Type: Rigid Insulation Board
Thickness: 3" (max.)
Properties:
Density: 2.25 pcf(lbs/ft3) min.
Or Compressive Strength: 20 psi min.
Insulation Notes:
• Rigid Insulation shall meet minimum density OR compressive strength.
• Insulation shall comply with FBC Section 1508. When insulation is
incorporated, fastener length shall conform to penetrate thru bottom of
support a minimum of 3/16".
FL#: FL 5211.3-R6
Date: 7/ 1/ 15
�.hBUk"'"" �"' � .�.�- Report No.: 15-104-M-S6W-ER
L. �. �rorir; Page 5 of 7
Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064
Installation: Installation Method:
(Refer to drawings on Pages 6-7 of this report.)
• Fastener spacing: Refer to Table"A" Below
(along the length of the panel)
• Rib Interlock: Snap Lock
(Panel ribs shall be fully engaged to form an integral interlock. )
• Minimum fastener penetration thru bottom of support, 3/16".
• For panel construction at the end of panels, refer to manufacturer's instructions
and any site specific design.
TABLE "A"
ALLOWABLE LOADS
METHOD 1: METHOD 2:
* Design Pressure: -84.25 PSF -91.75 PSF
Deck Thickness: 15/32" or 19/32" 15/32" or 19/32"
Fastener Spacing: 8" 4"
*Allowable design pressure for allowable stress design(ASD)with a margin of
safety of 2 to 1.
Install the "M-Seam" roof panel assembly in compliance with the installation method
listed in this report and applicable code sections of FBC 5th Edition (2014). The
installation method described herein is in accordance with the scope of this
evaluation report. Refer to manufacturer's installation instructions as a
supplemental guide for attachment.
Referenced Data: 1. UL580-94 & UL 1897-98 Uplift Test
By Hurricane Test Laboratory, LLC (FBC Organization #TST ID: 1527)
Report#: 0232-0508-05, Report Date: 6/29/05, Specimens#1-3
2. Quality Assurance
By Keystone Certifications, Inc. (QUA ID: 1824)
Millennium Metals Licensee#423
3. Equivalency of Test Standard Certification
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization #ANE 1916)
4. Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization #ANE 1916)
FL#: FL 5211.3-R6
Date: 7/ 1/15
\CBUCK Engineering PageReprt No.: 65of 7 M-104 -ER
Specialty Structural Engineering CBUCK, Inc.Certificate of Authorization#8064
OFFICE COP
Installation Method
Millennium Metals
"M-Seam" Roof Panel Attached to Wood Deck
Profile Drawings
1"
16"CoverageI..H
_____01
L -- 1%, ,s,-'Optional Striations 3/4'
Typical Panel Profile View
16" o.c. a
Integral Snap Lock
#10 Pancake-Head Screw
3/16"min. penetration thru deck
'I,
Typical Assembly Profile View
\ FL#: FL 52113-R6
Date: 7/ 1/ 15
C'" UCK Engineering Page rt No.: ;so; Ms6wER
Speclattij Structural Engineering CBUCK,Inc.Certificate of Authorization#8064
Installation Method
Millennium Metals
"M-Seam" Roof Panel Attached to Wood Deck
Fastener:
#10 Pancake-Head Screw
"M-Seam"Roof Panel r_---T------------------
--------__7
/// ,,,,,/
r
/ / //
////
/� 8"o.c Typical
/
i/ / i /
/ /
Deck' Insulation:
-15/32"or 19/32"or greater Plywood,or (Optional)3"max or 25 psi min.
-Wood plank
Typical Assembly Profile View
TABLE "A"
ALLOWABLE LOADS
METHOD 1: METHOD 2:
* Design Pressure: -84.25 PSF -91.75 PSF
Deck Thickness: 15/32" or 19/32" 15/32" or 19/32"
Fastener Spacing: 8" 4"
*Allowable design pressure for allowable stress design(ASD) with a margin of
safety of 2 to 1.
Uri- .t LLW'
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation -Residential Performance Method
Project Name: Terrano 3218 Left E Builder Name: Toll Brothers
Street: Lot 128 Atlantic Beach CC Permit Office: Duval
City,State,Zip: Atlantic Beach, FL, Permit Number: '
Owner: Toll Brothers Jurisdiction: 261300
Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(3810.7 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=19.0 3605.70 ft2
b.Frame-Wood,Adjacent R=13.0 205.00 ft
3. Number of units, If multiple family 1 c. N/A • R= • ft2
4. Number of Bedrooms . 4 d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types (1672.0 sqft.) Insulation . Area
a. Under Attic(Vented) R=38.0 1446.00 ft2
6. Conditioned floor area above grade(ft2) 3218 b. Under Attic(Vented) R=19.0 . 226.00 ft2
ft2
Conditioned floor area below grade(ft2) 0 11.Ducts R R ft2
7. Windows(511.6 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:2nd.Floor. 6 453.
a. U-Factor: Dbl, U=0.34 511.61 ft2 '
SHGC: • SHGC=0.27
b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 60.0 SEER:14.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 60.0 HSPF:8.20
.SHGC:
Area Weighted Average Overhang Depth: 4.514 ft.
Area Weighted Average SHGC: 0.270 • 14. Hot water systems .
a. Natural Gas Tankless Cap: 1 gallons
8. FloorTypes (3218.0 sqft.) Insulation Area EF:0.800
a.Slab-On-Grade Edge Insulation R=0.0 1771.00 ft2 b. Conservation features
b. Floor Over Other Space R=0.0 1293.00 ft2 None ,
c. other(see details) R= 154.00 ft2 15.Credits Pstat
r
Total Proposed Modified Loads: .74.36 . , PASS
�+
Glass/Floor Area: 0.159 i r M.7
Total Baseline Loads: 90.27
YliiY,
rfifuJ„ 40i i
I hereby certify that the plans and specifications covered by Review of the plans and ,�"4 VVVIE,$ 4z ,�
this calculation are in compliance with the Florida Energy specifications covered by this 3 •v" ;; .��, ,--a... Off,
Code. calculation indicates compliance Lj iipy''t 4r - '
with the Florida Energy Code. mart*,' ,. . , ,uT., 1
PREPARED BY =�� �- . Before construction is completed ,w .--..Y-• �:•-•1$
DATE: �7�-0Z�- z '/8 this building will be inspected for ¢ i�t�1��0. i.�
y :•1_,
compliance with Section 553.908 • .k ...• • :;• ri
Florida Statutes. 'A' �•'. ' ,
I hereby certify that this building, as designed, is in compliance ,+vl� ,,,s':. ..0
with the Florida Energy Code. 4 � Q) 7-13'6t- ''
OWNER/AGENT: BUILDING OFFICIAL: rt
_ o�
DATE: DATE: 13*a0I O
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
•
7/2/2018 6:01 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017 •
PROJECT
Title: Terrano 3218 Left E Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 3218 Lot#
Owner Name: Toll Brothers Total Stories: 2 Block/Subdivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Toll Brothers Rotate Angle: 0 Street: Lot 128 Atlantic Beach .
Permit Office: Duval Cross Ventilation: No County: Duval
Jurisdiction: 261300 Whole House Fan: No City,State,Zip: Atlantic Beach ,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Jacksonville FL_JACKSONVILLE_INT 32 93 . 70 75 1281 49 Medium
BLOCKS
•
Number Name Area Volume
1 Blockl 3218 . 30733
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms Id'ID Finished Cooled Heated
1 Main 1771 17710 Yes 1 1 1 Yes Yes Yes
2 2nd Floor 1447 13023 No -4 3 1 Yes Yes Yes
FLOORS
• # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Floor over Garage . 2nd Floor ____ ____ 154 ft2 19 0 0 1
2 Slab-On-Grade Edge lnsulatio Main 155-ft 0 1771 ft2 -__- 0 0 1
3 Floor Over Other Space 2nd Floor ____ ____ 1293 ft2 0 0 0 1
• ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insula (deg)
1 Hip Composition shingles 2085 ft2 . 0 ft2 Medium 0.6 N 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1925 ft2 Y N
7/2/2018 6:01 PM EnergyGauge®O USA-FlaRes2017 Section R405.4.1.Compliant.Software_ ... -_ . __. Page 2 of 5
FORM R405-2017
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) 2nd Floor 38 Blown 1277 ft2 • 0.11 Wood
2 Under Attic(Vented) Main 38 Blown 169 ft2 0.11 Wood
3 Under Attic(Vented) Main - 19 Blown 56 ft2 0.11 Wood
4 , Under Attic(Vented) 2nd Floor 19 Blown 170 ft2 0.11 Wood
WALLS
Ad'acent Space Cavity Width Height Sheathing Framing Solar Below
# nrnt To Wall Type p R-Value-Ft In Ft In _-.Area R-Vatne Fraction-Ahgor. Grade%
_ 1 E Exterior Frame-Wood . 2nd Floor 19 39 B 9 0 357.0 ft2 0 0.23 0.6 0
.2 E Exterior Frame-Wood; . Main 19 .19 2 10 0 191.7 ft2 0 0.23 0.6 0
3 S Exterior Frame-Wood , • 2nd Floor 19 60 0 9 0 540.0 ft2 . 0 0.23 , 0.6 0
4 S Exterior Frame-Wood Main 19 61 2 10' 0 611.7 ft2 0 ' 0.23 0.6 0
_ 5 W Exterior Frame-Wood 2nd Floor 19 39 8 9 0 357.0 ft2 0 0.23 0.6 0
_ 6 W Exterior .Frame-Wood Main 19 39 8 10 0 396.7 ft2 0 0.23 0.6 0
•
_ 7 N Exterior Frame-Wood 2nd Floor 19 60 0 9 0 540.0 ft2 0 0.23 , 0.6 . 0
8 N Exterior Frame-Wood Main 19 61 2 10 0 611.7 ft2 0 0.23 0.6 0
_ 9 E Garage Frame-Wood Main 13 . 20 6 10 0 205.0 ft2 0 0.23 0.6 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height . Area
Ft In Ft In
1 SW, Insulated Main None .6 3 8 24 ft2
2 E Wood Main None .4 .2 '8 8 21.3 ft2
WINDOWS
Orientation shown is the entered,Pro.osed orientation.
/ Wall Overhang
• V # • Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 E 1 Vinyl Low-E Double, Yes 0.34 0.27 N 12.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5
• 2 E 1 Vinyl Low-E Double Yes 0.34 0.27 .-- N 12.0 ft2 7 ft 4 in 1 ft 0 in None Exterior 5
3 . E 2 Vinyl Low-E Double Yes 0.34 0.27 N 36.0 ft2 2 ft 4 in 1 ft 0 in None Exterior 5
4 S 3 Vinyl Low-E Double Yes 0.34 0.27 N 8.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5
5 S 3 Vinyl Low-E Double Yes 0.34 0.27 N 30.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5
- • 6 W 6 Vinyl Low-E Double . Yes 0.34 0.27 N 128.0 ft2 8 f 2 in 1 ft 6 in None Exterior 5
7 S 4 Vinyl Low-E Double Yes 0.34 0.27 N 3.6 ft2 1 ft 4 in 1 It 0 in None Exterior 5
8 W 6 Vinyl Low-E Double Yes 0.34 0.27 N 48.0 ft2 8 ft 2 in 1 ft 0 in None Exterior 5
9 W 5 Vinyl Low-E Double Yes 0.34 0.27 N 15.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5
10 N 8 Vinyl Low-E Double Yes 0.34 0.27 N 24.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5
11 N 7 Vinyl Low-E Double Yes 0.34 0.27 N 20.0 ft2 .1 ft 4 in 1 ft 0 In Drapes/blinds Exterior 5
12 N 7' Vinyl Low-E Double Yes 0.34 0.27 N 24.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5
13 E 2 Vinyl Low-E Double Yes 0.34 0.27 N 16.0 ft2 8 ft 4 in 1 ft 0 in. None Exterior 5
14 W 6 Vinyl Low-E Double ' Yes 0.34 0.27 N 36.0 ft2 . .1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5
15 W 5 'Vinyl Low-E Double - Yes 0.34 0.27 , N 35.6 ft2 4 ft 8 in 1 ft 0 in Drapes/blinds Exterior 5
16 N 7 Vinyl Low-E Double Yes 0.34 0.27 N 8.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5
17 E 1 Vinyl Low-E Double Yes 0.34 0.27 N 15.0 ft2 7 ft 4 in 1 ft 0 in None Exterior 5
7/2/2018 6:01 PM.. • EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software__._ Page 3 of_5
FORM R405-2017
WINDOWS
Orientation shown is the entered,Prososed orientation.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation ' Int Shade Screening
18 W 5 Vinyl Low-E Double Yes 0.34 0.27 N 4.5 ft2 1 ft 4 in 1 ft 0 in None Exterior 5
19 S 4 Vinyl Low-E Double Yes 0.34 0.27 N 18.0 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds Exterior 5 •
20 N 8 Vinyl Low-E Double Yes 0.34 0.27 N 18.0 ft2 1 ft 4 in 1 ft 0 in None Exterior 5
GARAGE
# Floor Area Ceiling Area . Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation .
. 1 425 ft2 . 425 ft2 74 ft 10 ft .. 0
•
INFILTRATION •
4 Scope Method SLA CFM 50 ELA EqLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000425 3585.5 196.84 370.19 .4027 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity . Block Ducts
1 Electric Heat Pump/ None HSPF:8.2 60 kBtu/hr •
1 sys#1
COOLING SYSTEM
4f System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER: 14 60 kBtu/hr 1800 cfm 0.78 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Natural Gas Tankl2ss Exterior 0.8 1 gal 55.1 gal 120 deg None
• SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
•
None None ft2
DUCTS
/ ----Supply---- ----Return--- Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 453 ft2 Attic 149 ft2 Default Leakage 2nd Floor (Default) (Default) 1 1
7/2/2018 6:01 PM EnergyGauge®USA-FlaRes2017-Section.R405.4.1.Compliant.Software.. Page 4 of 5
FORM R405-2017
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Coolin [[ ]Jan [[ Feb [[ ]Mar Apr Ma Jun X Jul X Au Se Oct Nov Dec
Venting [X]Jan [X�Feb [X]Mar tXX Apr t I May �i Jun t 1 Jul t i Aug [ Sep �X�Oct �X�Nov �X�Dec
Venting [[ ]]]Jan [[ Feb [[X]Mar
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) . AM 78 78 78' 78 78 78 78 78 80 80 80 80
PM • 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEN) AM 78 78 78 78 78. 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68'• • 68 68 68 68 68 68 68 66 66
• Heating(WEH) AM 66 66 • 66 66 66 68 68 68 68 68 68 68
• PM 68 • 68' ' 68 68 68 68 68 68 68 68 66 66
•
•
•
''-- 7/2/2018 6:01 PM -EnergyGauge®-USA-FlaRes2017 Section_R405.4.1_Compliant Software Page 5 of 5
FORM R405-2017q
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY- CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 82
The lower the EnergyPerformance Index, the more efficient the home.
Lot 128 Atlantic Beach CC, Atlantic Beach, FL, .
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Frame Wood, Exterior R=19.0•
3605.70 ft
b.Frame-Wood,Adjacent R=13.0 205.00 ft
3. Number of units,if multiple family 1 • c.N/A • R= ft2
4. Number of Bedrooms • 4 d. N/A R= ft2
10.Ceiling Types Insulation Area
5. Is this a worst case? No •
a.Under Attic(Vented) R=38.0 1446.00 ft2
6. Conditioned floor area(ft2) 3218 b. Under Attic(Vented) R=19.0 226.00 ft2
c. N/A R= ft2
7. Windows** ' Description Area
11.Ducts R ft2
a. U-Factor: Dbl,U=0.34 511.61 ft2
a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 453
SHGC: SHGC=0.27
b. U-Factor: N/A ft2
SHGC: , 12.Cooling systems kBtu/hr Efficiency
c. U-Factor. N/A ft2 a.Central Unit 60.0 SEER:14.00
SHGC: 1
d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 60.0 HSPF:8.20
Area Weighted Average Overhang Depth: 4.514 ft.
Area Weighted Average SHGC: 0.270 •
8. Floor Types Insulation _ Area 14.Hot water systems Cap: 1 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1771.00 ft2 a. Natural Gas EF:0.8
b. Floor Over Other Space R=0.0 1293.00 ft2
c.other(see details) R= 154.00,ft2 b. Conservation features
None
15.Credits Pstat
I certify that this home has complied vvith the Florida Energy Efficiency Code for Building �`0HEsT"�
Construction through the above energy saving features which will be installed (or exceeded) ytio ., A�',w
in this home before final inspection. Otherwise, a new EPL Display Card will be completed - '4•••••;/./ �`.r4, ,•1 t,.
based on installed Code compliant features. d.` / ,,.,\•�
_ y :5 i
Builder Signature: Date: Q% 1 tjf
g
Address of New Home: City/FL Zip: t'4, 00...... .,., ...-, �
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/2/2018 6:01 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1
•
Florida Building Code, Energy Conservation, Gth Edition (2017)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: Lot 128 Atlantic Beach CC Permit Number:
Atlantic Beach,FL,
•
MANDATORY REQUIREMENTS See individual code sections for full details.
SECTION R401 GENERAL
R401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require'that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
(Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level andefficiencies of components
installed in a dwelling unit.The building official.shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for the building,A copy of the EPL display card can be found in Appendix RD.
R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing .
methods between dissimilar materials shall allow for differential expansion and contraction.
R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required
by the code official,an approved third party shall inspect all components and verify compliance.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
•
changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in
% accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either
individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or
an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions, alterations, renovations,or repairs,of the building thermal envelope of existing .
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended
weatherstripping or other infiltration control measures.
2. Dampers Including exhaust, intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond
intended infiltration control measures.
3. Interior doors,if installed at the time of the test,shall be open. •
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
•
5. Heating and cooling systems, if installed at the time of the test,shall be turned off.
6. Supply and return registers,if installed at the time of the test,shall be fully open.
R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where
using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the
•
fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907.
R402.4.3 Fenestration air leakageWindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per .
•
square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. •
Exception: Site-built windows,skylights and doors.
•
7/2/2018 6:02 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 1 of 5•
•
MANDATORY REQUIREMENTS - (Continued)
R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to
open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions: • •
• 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. • •
R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
- between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakagerate not
•
more than 2.0 cfm(0.944 Us)when tested In accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed:
•
• •luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. .
SECTION R403 SYSTEMS
R403.1 Controls.
R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section
•
C403.2.9.2.of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below: . •
•
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or
(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i),Florida Statutes,to be"substantially leak free"in
accordance with Section R403.3.3.'
R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
R403.3.3 Duct testing(Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system, including the
manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test.
2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g,(25 Pa)across the
entire system,including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the .
test.
— . -Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code. . •
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
.
R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
•
R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)
•
or below 55°F(13°C)shall be insulated to a minimum of R-3.
R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that
caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause
degradation of the material.Adhesive tape shall not be permitted.
R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in
accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2.
Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible.
•
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return
pipeshall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited. .
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the
occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water.
R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems
shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance
with the times when heated water is used in the occupancy.
7/2/2018 6:02 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017)Complian Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3%inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
•
R403.5.6 Water heater efficiencies(Mandatory).
R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable •
•
of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature
setting range shall be from 100°F to 140°F(38°C to 60°C). •
R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of •
combustion types of service water-heating systems to be turned off.
R403.5.6.2 Water-heating equipment. • Water-heating equipment installed in residential units shall meet the minimum efficiencies of •
Table C404.2 In Chapter 4 of the Florida Building Code, Energy Conservation,Commercial Provisions,for the type of equipment installed. •
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for.the appropriate .
water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
• R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy • .
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar
water-heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation
including:Natural, Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical
ventilation system,fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be
powered by an electronically commutated motor..
R403.6.2 Ventilation air. • When installed to function as a whole-house mechanical
ventilation system,fans shall meet the efficacy requirements of Table R403.6.1.
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable
Indoor Air Quality,shall be the.maximum rates allowed for residential applications. •
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawispaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10
otherwise. • •
R403.7 Heating and cooling equipment(Mandatory).
R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, •
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and -
indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other.factors that
affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such
as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency
rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. .
TABLE R403.6.1
WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMUM
(CFM) (CFM/WATT) (CFM)
Range hoods Any 2.8 cfm/watt Any
•
In-line fan Any 2.8 cfm/watt Any
Bathroom, utility room 10 1.4 cfm/watt <90
Bathroom,utility room 90 2.8 cfm/watt Any
For SI: 1 cfm=28.3 L/min. a. When tested in accordance with HVI Standard 916
7/2/2018 6:02 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 3 of 5
MANDATORY REQUIREMENTS - (Continued)
R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the .
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing. Manufacturer's
expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded
performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature.
Designvalues for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load.
•
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the • .
• • calculated total sensible load but not less than 80 percent of that load. •
2.
When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity.of -
equipment maybe sized in accordance with good design practice. ... .•-
R403.7.1.2 Heating equipment capacity.. .
R403.7.1.2.1 Heat pumps. • .Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
- R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design •
requirements calculated according to the procedure selected in Section R403.7.1.
. R403:7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. •
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403.
R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F.(4.8°C).
R403.10 Pools and permanent spa energy consumption(Mandatory)._ . . The energy consumption of pools and permanent spas •• ••
shall be in accordance with Sections R403.10.1 through R403.10.5.
R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an
•
integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation
of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the
power to the heater. Gas-fired heaters shall not be equipped with continuously burning ignition pilots.
•
R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule .
shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be incompliance with this
section.
Exceptions: •
1. Where public health standards require 24-hour pump operation. .
2. Pumps that operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating,computed over an operation season, is from site-recovered
energy,such as from a heat pump or solar energy source, covers or other vapor-retardant means shall not be required.
R403.10.4 Gas-.and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal
efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
7/2/2018 6:02 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 4 of 5
R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
R403.11 Portable spas(Mandatoryl)he energy'consumption of electric-powered portable spas shall be controlled by the
requirements of APSP-14.
•
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
•
R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be
high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps.
•
Exception:Low-voltage lighting. • .
•
R404.1.1 Lighting equipment(Mandatory).Fuel gas lighting systems shall not have continuously burning pilot lights.
•
•
•
•
•
•
•
•
7/2/2018 6:02 PM EnergyGauge®USA-FlaRes2017 FBC 6th Edition(2017) Complia Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Terrano 3218 Left E Builder Name: Toll Brothers
Street: Lot 128 Atlantic Beach CC Permit Office: Duval
City, State,Zip: Atlantic Beach ,FL, Permit Number:
Owner: Toll Brothers Jurisdiction: 261300
Design Location: FL,Jacksonville
•
COMPONENT AIR BARRIER CRITERIA . INSULATION INSTALLATION CRITERIA '
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit '
the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls.
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with
sealed. a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed. minimum.
Exterior thermal envelope insulation for framed walls
• shall be installed in substantial contact and •
continuous alignment with the air barrier.
Windows,skylights The space between window/door jambs and framing,'and
and doors skylights and framing shall be sealed. •
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. •
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation. • • maintain permanent contact with the underside of
above-garagesubfloor decking,or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side
floors) of sheathing,or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
.. members.
•
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation
' a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls.
Shafts, penetrations ,Duct shafts,utility penetrations,and flue shafts opening to
•
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
cavities shall be filled by insulation that on
Narrow cavities
'installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces. .
Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building
shall be sealed to the drywall. . thermal envelope shall be air tight and IC rated.•
Plumbing and wiring. Batt insulation shall.be cut neatly to fit around wiring
and plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall,
on exterior wall tubs shall separate them from the showers and tubs. be insulated. . _
Electrical/phone box or The air barrier shall be installed behind electrical or communication '
exterior walls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall '
be sealed to the sub-floor or drywall. V
Concealed When required to be sealed,concealed fire sprinklers shall only be •
sprinklers sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or ceilings.
a.In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
7/2/2018 6:02 PM EnergyGauge®USA-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
Ta b-e. camel-eTxq • —0 /l . 1VQ.- a
•
FORM R405-2017 Envelope Leakage Test Report Performance C . 0,
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION OFFICE Envelope Leakage Test Report
Performance Method
...War__._. __ _ .._._.__.,W.y___. W ._.___ .
Project Name: Terrano 3218 Left E Builder Name: Toll Brothers
Street: Lot 128 Atlantic Beach CC Permit Office: Duval •
' City,State,Zip: Atlantic Beach, FL, Permit Number:
. Design Location: FL,Jacksonville • . Jurisdiction: 261300.
Cond.Floor Area:: 3218 sq.ft. Cond.Volume: 30733 cu ft.
•:Envelope Leakage Test Results Leakage Characteristics .
•
Regression Data:.
C: n: R: .
Single or Multi Point Test Data Required ACH(50) from
HOUSE PRESSURE FLOW: • FORM R405-2017 :
1 . Pa cfm /
.2 Pa cfm Tested ACH(50).* :
3 Pa cfm '
*Tge must be less than or eq
4 Pa .. cfm requiredested ACH(50)leakashown on Form 8405 2017ualto for
• 5 Pa • cfm . this building. If the tested ACH(50)is less than 3
• the building must have a mechanical ventilation
• 6 _ Pa . cfm system.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour
in Climate Zones 1 and 2...Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by
either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g),or(i)or an
approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing
shall be performed at any time after creation of all penetrations of the building thermal envelope.
.During testing: :: .: . ... ... ..... .
• .1.Exterior windows and doors,fireplace and stove doors shall be closed, but not sealed,beyond the intended weatherstripping or other
infiltration control measures;
2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration
control measures;
3. Interior doors,If installed at the time of the test,shall be open;
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and.sealed;.
5. Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
+40 'iiora..i.•-
. I hereby certify that the above envelope leakage Testing.shall be conducted by either ,, •'p1 tixE.ST,q?
individuals as defined in Section •� .; ,,.',4 D
• performance results demonstrate compliance , ,� .,��;r� �.
553.993 5 or 7 , Florida.Statutes or fi„
with Florida Energy Code requirements in O O �.���r�;' ,,,.,.,;,,��� �'`
accordance with Section R402.4.1.2. individuals licensed as set forth in Q,. ,:',.-:.;..":',::...,;.'.T.1„ o
P • Section 489.105(3)(f), (g);or(i)or an w` 01117; -+
approved third party.A written report of �', 1�� r - d
csg E.
the results of the test shall be signed , A * •• � :.� ,
SIGNATURE: by the third party conducting the test �.�;',-, .•'S`S*•
andprovided to the code official. '
CDDWt„', .
PRINTED NAME: �”""""'"-
BUILDING OFFICIAL:
DATE: DATE: �' r3. 0013-
7/2/2018
3' 70J37/2/2018 6:02 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1
Project Summary Date:
Lot 128 ABCC
}ttejf tlld j i' Main By: Saldie Guintivano
McGowan's Heating & Air Conditioning
11320 E.Phillips Parkway Dr.,Jacksonville,Fl 32256 Phone.904-278-0339 Fax:904-278-0366 Email:saldie@mcgowansac.com Web:www.mcgowansac.com License:CMC12...
"} } s ysas. v? t,.:.,,,,,,,4.;:,!.�p 1 a' .. �y°h f
.. ,,.tiiii.- - nv..Y #:� t air i .. , A' t .i.
,
sx',a„'d .E�„ Aif. We,. �* n.Jfi. .i + : Prci ee n „rt :tiot s1 ri i --. ,� . .4 a.. ..."'Le-- . :-._',, v,-
For: Steve Merten, Toll Brothers, Inc.
160 Cape May Ave., Ponte Vedra, Fl 32081
Phone: (904) 217-0739 Fax: (904) 814-8173
Web: www.tollbrothers.com Email: smerten@tollbrothersinc.com
Notes: The Terrano
-i, t 3 }� ..,,,:-.,;,,,,:,:,%....,,,,s,...:,,,„.;;;:..;..,� rLQtµcl-( ',,i z /ems'°”- '.4.--r- p/�-::,,;. i .�4-4'-'=
� a lm "S4 t s cjia d• rr'.
{a : ., , <';4.14 rt .3.. .,,�. 4 ,.s. ",`�„w4,b'b�c t.;DesI 'Ilnfo .mat'on 5�>#�i.x',:'t t aiiz'ta, t itt'��.ai .'" '.
Weather: Jacksonville NAS, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 32 °F Outside db 99 °F
Inside db 70 °F Inside db 75 °F
Design TD 38 °F Design TD 24 °F
Daily range M
Relative humidity 50 %
Moisture difference 61 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 37407 Btuh Structure 31032 Btuh
Ducts 6087 Btuh Ducts 7583 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 43495 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 39717 Btuh
Method Blower door Latent Cooling Equipment Load Sizing
Shielding/stories 3 (partial)/2
Pressure/AVF 50 Pa/3613 cfm Structure 9774 Btuh
Ducts 1355 Btuh
Central vent (0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft2) 3248 3248 Equipment latent load 9883 Btuh
Volume (ft3) 30127 30127
Air changes/hour 0.68 0.42 Equipment Total Load (Sen+Lat) 49600 Btuh
Equiv. AVF (cfm) 339 212 Req. total capacity at 0.70 SHR 4.7 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING
Model CH14NB0600000A0 Cond CH 14NB0600000A0
AHRI ref 9162972 Coil FX4DNB061L
AHRI ref 9162972
Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER
Heating input Sensible cooling 39900 Btuh
Heating output 54500 Btuh @ 47°F Latent cooling 17100 Btuh
Temperature rise 28 °F Total cooling 57000 Btuh
Actual air flow 1750 cfm Actual air flow 1750 cfm
Air flow factor 0.040 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.78
Capacity balance point=27°F
Backup:
Input= 13 kW, Output=43495 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
+3 wricc'htsatt 2018-Jul-02 17:18:13
`:--. .. •- - Comfort Builder by Wrightsoft 18.0.19 RSU03444 Page 1
ACCK ...\Desktop\Terrano 3218 Left E-Lot 128 ABCC.rup Calc=MJ8 Front Door faces: E
- ; . N
11-to'
/ First Floor
I
6 x 14
Bedroom z
Breakfast
8"
12x12 10x10
97,;
Family Roon
12x6
7" IJ
3" Fan r �� •
t - 16x16
I ';Bath 14"
8x4
•
Kitchen
10x10
10x6
5 12 __. 7..
Stair
mud roon
10x10
0.4 6 x 12
7"
111 10"
Hall 1
Dining Room
10x6
10x6
6 6'
Stud}
GaragE
Foyer
Job #: Lot 128 ABCCMcGowan's Heating & Air Conditioni Scale: 1 : 94
Performed by Saldie Guintivano for: Page 1
Steve Medan 11320 E.Phillips Parkway Dr. Comfort Builder by Wrightsoft
160 Cape May Ave. Jacksonville,Fl 32256
18.0.19 RSU03444
Ponte Vedra,Fl 32081
Phone:904-278-0339 Fax:904-278-0366 2018-Jul-02 17:18:32
Phone:(904)217-0739 Fax:(904)814-8173 memc www.mcgowansac.com saldie owansac.com
www.tollbrothers.com smerten@tollbrothersinc.com g @ g ...o 3218 Left E-Lot 128 ABCC.rul
VI1
--"lec—
Second Floor - r-
Walk-In 1
8x4
e 4" Master Bedroor
12 x 6
Bedroom< 7" ..
1. 9„ 12
Rim
16x16 10x6 10x6
12x12 ¢ 6„
. 14"
9" 11� If [,i 6„ `AI
\ IJ e Laundry ■ •,;.;
e. Ox1l 8x4
e 6" r 9ir 18x18 i 4" n
6x10 18 14^ wc'
Ili
8 x 4 5 14'`^^^^--^^^,ff 10 x 10 10 x 6
Bath 3 4" e U 5 11
10"
- Hall 3
0 Master Bat'
3" Fan Hall 4 Stair 2
0 3" Fan
12 x 12
I 9„ 6x6101,°
11
r''
Bedroom': 12 x 6:1
7"
Loft
S
1-----
,
t
1 of
10x6
6"
Foyer up
Job #: Lot 128 ABCCMcGowan's Heating & Air Conditioni Scale: 1 : 94
Performed by Saldie Guintivano for: Page 2
Steve Merten 11320 E.Phillips ParkwayDr.
Cape May Ave. p Comfort Builder by Wrightsoft
160
perFl 32081e. Jacksonville,Fl 32256 18.0.19 RSU03444
PontPhone:904-278-0339 Fax:904-278-0366 2018-Jul-0217:18:32
Phone:(904)217-0739 Fax:(904)814-8173 mc www. owansac.com saldie me owansac.com
www.tollbrothers.com smerten@tollbrothersinc.com g �° g ...o 3218 Left E-Lot 128 ABCC.rul
Manual S Compliance Report Date: Lot 128ABCC
IViain By: Saldie Guintivano
IVIcGowan's Heating & Air Conditioning
11320 E.Phillips Parkway Dr.,Jacksonville,Fl 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie@mcgowansac.com Web:www.mcgowansac.corn License:CMC12...
':'C3 •�t,bt.(ii S.7P. x** 1 ']afsu8`ha:.'' e�,5" `S.t},f�¢k,"k?4a 7NaE.�i...3 � Y'+� + 5:-td r+tiR,.1 .f t.:'y+n .t.x.. A . r., , r ...
For: Steve Merten, Toll Brothers, Inc.
160 Cape May Ave., Ponte Vedra, Fl 32081
Phone: (904) 217-0739 Fax: (904) 814-8173
Web: www.tollbrothers.com Email: smerten@tollbrothersinc.com
Design Conditions
Outdoor design DB: 99.2°F Sensible gain: 39717 Btuh Entering coil DB: 75.9°F
Outdoor design WB: 80.2°F Latent gain: 9883 Btuh Entering coil WB: 63.0°F
Indoor design DB: 75.0°F Total gain: 49600 Btuh
Indoor RH: 50% Estimated airflow: 1750 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: CH14NB0600000A0+FX4DNB061L
Actual airflow: 1750 cfm
Sensible capacity: 39070 Btuh 98% of load
Latent capacity: 9732 Btuh 98% of load
Total capacity: 48802 Btuh 98% of load SHR: 80%
r� � p�yk jfs ��ttt ,y �,f8 '`x q♦yv,�yl. �i `6 yj$n 4�� Y; i w � 9 ? .{J`7■ /��^ `T`'t E1�' t x .:� t r
Design Conditions
Outdoor design DB: 31.7°F Heat loss: 43495 Btuh Entering coil DB: 69.6°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: CH14NB0600000A0+FX4DNB061L
Actual airflow: 1750 cfm
Output capacity: 43404 Btuh 100% of load Capacity balance: 27 °F
Supplemental heat required: 91 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 1750 cfm
Output capacity: 12.7 kW 100% of load Temp. rise: 106 °F
Meets all requirements of ACCA Manual S.
Wr'T+CJ'litsoft•
2018-Jul-02 17:18:13
Comfort Builder by Wrightsoft 18.0.19 RSU03444 Page 1
ACC
.\Desktop\Terrano 3218 Left E-Lot 128 ABCC.rup Calc=MJ8 Front Door faces: E
Duct System Summary Job: Lot 128ABCC
,,, r Date:
�tfi tit;>a{.�Grllt�! � ' IVIain By: Saldie Guintivano
IVIcGowan's Heating & Air Conditioning
11320 E.Phillips Parkway Dr.,Jacksonville,Fl 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie@mcgowansac.com Web:www.mcgowansac.com License:CMC12...
tl��"'i1i���0.{$.L � , t',. -.,....3•14,-' 7.;' -4,0 :.1-t-,..,4::-:."%p X 42 t x.- (q{A��,IQ� H - P tea j
�rci:Yg 4Y N 1 ;r: t E34':.,�. - 1 k,i. 'r,z..,.; ..,. � �71. T IT R4,Yl7.t,.? :!1 i f J ., c .- .
� d..�stkxr.;��._ 4_ a: �a�'tcF } �c.z . ,>4ui,� � ;��I3i.. ..r�,��wt°,.�r'ar.k,+a.-.., • .te.. � ;.,'.v.,''.7;',,:,,,.0.1',...
For: Steve Merten, Toll Brothers, Inc.
160 Cape May Ave., Ponte Vedra, Fl 32081
Phone: (904) 217-0739 Fax: (904) 814-8173
Web: www.tollbrothers.com Email: smerten@tollbrothersinc.com
,..,4.-.14.1,..1,xi.r.,.q ..:.,a,+b, Ni34s..:i,..4. t,: . ,....,, ,.4,..:i„st..4 :i., sa ..7.:, - r..,,.RAZ.;:az„wv ,W.>..,,> ..d. : `zs.f:.,,r.c A�,..+:.:�,a.,,......,, ,.•,.r•' t .:.,,, • i-;,L
Heating Cooling
External static pressure 0.50 in H2O 0.50 in H2O
Pressure losses 0.11 in H2O 0.11 in H2O
Available static pressure 0.39 in H2O 0.39 in H2O
Supply/return available pressure 0.238/0.152 in H2O 0.238/0.152 in H2O
Lowest friction rate 0.072 in/100ft 0.072 in/100ft
Actual air flow 1750 cfm 1750 cfm
Total effective length (TEL) 545 ft
i.�§ h � .1'!.
, '
ins r . 0 upplyEerancip.11 ?R4W N !, ( p k3 s S''-'4. a ,1
Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv
Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk
Bath h 813 33 14 0.130 4.0 Ox 0 VIFx 30.7 152.0 st2
Bath 3 h 865 35 29 0.115 4.0 Ox 0 VIFx 22.7 185.0 st3
Bedroom 2 h 3000 121 116 0.084 7.0 Ox 0 VIFx 47.0 235.0 st5
Bedroom 3 C 2677 112 121 0.123 7.0 Ox 0 VIFx 13.1 180.0 st3
Bedroom 4 h 3996 161 134 0.131 7.0 Ox 0 VIFx 29.2 152.0 st2
Breakfast h 4137 166 125 0.072 7.0 Ox 0 VIFx 85.7 247.0 st7
Dining Room h 4085 164 129 0.074 7.0 Ox 0 VIFx 70.2 252.0 st7
Family Room c 7246 150 328 0.124 8.0 Ox 0 VIFx 35.7 157.0 st2
Hall 1-A h 3099 125 86 0.094 6.0 Ox 0 VIFx 56.2 197.0 st6
Kitchen c 2405 104 109 0.075 7.0 Ox 0 VIFx 72.2 247.0 st7
Laundry-A c 797 5 36 0.124 5.0 Ox 0 VIFx 16.5 175.0 st3
Loft h 2039 82 75 0.087 6.0 Ox 0 VIFx 37.6 235.0 st5
Loft-A h 2039 82 75 0.085 6.0 Ox 0 VIFx 46.1 235.0 st5
Master Bath h 2217 89 70 0.115 5.0 Ox 0 VIFx 22.5 185.0 st4
Master Bedroom c 2064 86 94 0.115 6.0 Ox 0 VIFx 22.0 185.0 st4
Master Bedroom-A c 2064 86 94 0.116 6.0 Ox 0 VIFx 20.1 185.0 st4
Study h 912 37 28 0.095 6.0 Ox 0 VIFx 53.2 197.0 st6
Walk-In 1 c 779 34 35 0.126 4.0 Ox 0 VIFx 13.5 175.0 st3
mud room h 1650 66 44 0.130 5.0 Ox 0 VIFx 30.8 152.0 st2
we h 289 12 8 0.115 4.0 Ox 0 VIFx 22.7 185.0 st4
, �J lt:3OFt,.. 2018-Jul-0217:18:13
/_ Wr1
Comfort Builder by Wrightsoft 18.0.19 RSU03444 Page 1
ACCK ...\Desktop\Terrano 3218 Left E-Lot 128 ABCC.rup Calc=MJ8 Front Door faces: E
klJ y.y€rte. e, 14r C3''3. tijai, }inniA vii, r3;?i4F [ IA rrfkle%y (ArV i w43.. 4 ',3 ? G -'.,, T.
v,02xee1Rimb.::„ i '.an:: en. : .-3 LeARti' PiaA„k,g}Fb i..41.0;•'-411.A. ''.,•3`;': ...f....,. `v 1r R.t
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
st7 Peak AVF 435 363 0.072 797 10.0 0 x 0 VinlFlx st6
st6 Peak AVF 596 477 0.072 759 12.0 0 x 0 VinIFIx st2
st5 Peak AVF 285 266 0.084 522 10.0 0 x 0 ViniFlx st4
st3 Peak AVF 186 221 0.115 501 9.0 0 x 0 VinIFIx st1
st4 Peak AVF 558 531 0.084 710 12.0 0 x 0 VinlFlx st1
st1 Peak AVF 744 753 0.084 704 14.0 0 x 0 VinIFIx
st2 Peak AVF 1006 997 0.072 941 14.0 0 x 0 ViniFlx
r °x{A' r .q : . 3 t rc yrs �4,R -x .��Sadli x is st „,,ana P #-,-i, rt . ,y;
�1 r ♦ ” r a r
.toti
} � v?1„,` t= -c �5, ��Jt>z �f{�`U urn., �1`+ }}} �^ aft x �k+s t � s k i t i 3 t i , o.+.
� ikt o—',1 SX ;:,,,=110444,1zM td� iFt3 Yi N; i&4� 4",-.;'r'F 9F r i. RfR>� . � :,A1; .,SkM1:RJ.�:•.!:(.•:.%.,..w#;,.y•. •1.. .. ;.•.�Fa••,•y::.•,..:4'
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk
rb4 Ox 0 177 223 112.0 0.136 209 14.0 Ox 0 VIFx rt3
rsb3 Ox 0 577 646 137.1 0.111 1462 9.0 Ox 0 VIFx rt5
rb3 Ox 0 292 261 212.0 0.072 661 9.0 Ox 0 VIFx rt4
rb5 Ox 0 181 185 205.5 0.074 419 9.0 Ox 0 VIFx rt4
rb6 Ox 0 94 83 148.5 0.102 350 7.0 Ox 0 VIFx rt3
rb9 Ox 0 429 352 167.1 0.091 547 12.0 Ox 0 VIFx rt5
'Y t,-.sn di.:,--,i o.r: »,. , 'y;£k a , H',I ‘ .,:'`,. >..as ax> »C i :t" r s N , + F y..;
uA ry 4,,,g , `', 714 . i tR d n:,,I.t.A �s 4 r� T ry l''It + s i , " ti7 4
Si3�,3$�:�kS.,'a,�t.r.:.iia?H.c .&-5� 3r1.�+��:��i.W.g.7z�,�i &'�«K'=t'a�i��'���.::.�� � R.R+�i���.. -C'!n'���r�� e7r._ �A 1��:'a,b.#3E. "'�. a mil ��.,�r..t .5 ..is.S ���t:'r.`^'t,,
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
rt3 Peak AVF 271 307 0.102 287 14.0 0 x 0 VinIFIx rt1
rt5 Peak AVF 1006 997 0.091 941 14.0 0 x 0 VinIFIx rt2
rt4 Peak AVF 473 446 0.072 442 14.0 0 x 0 VinIFIx rt1
rt1 Peak AVF 744 753 0.072 426 18.0 0 x 0 VinIFIx
rt2 Peak AVF 1006 997 0.091 2277 9.0 0 x 0 VinlFlx
w rights o f#' 2018-Jul-02 17:18:13
.. ,,. ..., . ,.. Comfort Builder by Wrightsoft 18.0.19 RSU03444 Page 2
Ck ...\Desktop\Terrano 3218 Left E-Lot 128 ABCC.rup Calc=MJ8 Front Door faces: E