292 16TH ST - ADDITION PERMIT .,: '- .1%-/c-,,,, RESIDENTIAL ADDITION PERMIT PERMIT NUMBER _. a .h CITY OF ATLANTIC BEACH r �r RESA18-0023 ISSUED: 10/9/2018 00 SEMINOLE ROAD `'` �`�` 8ATLANTIC BEACH. FL 32233 EXPIRES: 4/7/2019 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies,or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: RESIDENTIAL ADDITION SINGLE 292 16TH ST OR TWO FAMILY RESIDENTIAL $95000.00 ADDITION TYPE OF REAL ESTATE ZONING: . BUILDING USE SUBDIVISION: CONSTRUCTION: ' NUMBER: GROUP: j 170385 0000 ATLANTIC BEACH PRKWY #02 COMPANY: ADDRESS: CITY: i STATE: ZIP: CAUDEL& ASSOCIATES LLC 151 COLLEGE DR APT 17 ORANGE PARK FL 32065 OWNER: ADDRESS: CITY: STATE: ZIP: DAY JEFFREY E 292 16TH ST ATLANTIC BEACH FL 32233 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL ' Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line(904-247 -5814)to request an Erosion and Sediment Control Inspection prior to start of construction. Issued Date: 10/9/2018 1 of 2 ,�5� L'!, RESIDENTIAL ADDITION PERMIT PERMIT NUMBER JS ?# ~y p, � '.- s CITY OF ATLANTIC BEACH RESA18-0023 ').r �� 800 SEMINOLE ROAD ISSUED: 10/9/2018 v�Lusl9' ATLANTIC BEACH. FL 32233 EXPIRES: 4/7/2019 2 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 3 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list(Advanced Disposal,Realco Recycling,Shapell"s,Inc.,Republic Services, Donovan Dumpsters). Container cannot be placed on City right-of-way. 4 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration,including sod,is required. 5 PUBLIC WORKS RUNOFF INFORMATIONAL Notes: All runoff must remain on-site. Cannot raise lot elevation. 6 PUBLIC WORKS MAXIMUM DRIVEWAY INFORMATIONAL Notes: Maximum driveway width within the City right-of-way is 20 feet. 7 PUBLIC WORKS PERVIOUS PAVERS INFORMATIONAL Notes: Pervious pavers must be used to receive 50%credit. FEES h. 1LL. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $460.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $230.00 BUILDING PLAN REVIEW RESUBMITTAL SECOND 455-0000-322-1006 0 $50.00 PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $11.10 STATE DCA SURCHARGE 455-0000-208-0600 0 $7.40 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $50.00 TOTAL:$908.50 Issued Date: 10/9/2018 2 of 2 51..i.‘% City of Atlantic Beach APPLICATION NUMBER (d z #\ Building Department (To be assigned by the Building Department.) '11:- '-` 800 Seminole Road or) ; el Atlantic Beach, Florida 32233-5445 1&S ft I g -to 013 Phone(904)247 5826 Fax(904) 247-5845 4,11,,% E-mail: building-dept@coab.us Date routed: 8 2 i/1 City web-site: http://www.coab.us ! — APPLICATION REVIEW AND TRACKING FORM Property Address: 292.. ` (Q _ De•artment review required Yes No J I :we', Applicant: C&ude( '.BL ( lc( Planning &Zo..,. Tree Administrator On, I�eIYdl� cWProject: brY\ ika [rh u lic Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ['Approved. ®Denied. ❑Not applicable (Circle one.) Comments: BUILDING r � PLANNING &ZONING Reviewed by: / Date: / 7^1 r TREE ADMIN. Second Review: XrApproved as revised. I 'Denied. fNot applicable PUBLIC WORKS Comments: PUBLIC UTILITIES ' PUBLIC SAFETY Reviewed by: Mii Date: 10`if`aol, FIRE SERVICES Third Review: ❑Approved as revised. ['Denied. ENot applicable Comments: Reviewed by: Date: Revised 05/19/2017 Building Permit 12 8 v i / City of Atlantic Beach OFFICE CO 800 Seminole Road,Atlantic Beach,FL 32233 Phone:(904)247-5826 Fax:(904)247-5845 p Job Address: 292 16th Street,Atlantic Beach,FL 32233 Permit Number: I2ES!p,1 -06z 3 Legal Description 15-83 16-2S-29E.15 ATLANTIC BEACH PARKWAY UNIT NO 02LOT 5,6(EX PT RAN)B LK RE# 120,3KSr—.' 0061 Valuation of Work(Replacement Cost)$615 r 00° Heated/Cooled SF 1754 Non- Heated/Cooled 73° • Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): Commercial Residential • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: Addition R_OOrYM dO l,--\Y\ I. ld� 2bnv Florida Product Approval# for multiple products use product approval form Property Owner Information Name: Jeffrey and Diane Day Address: 262 16th Street City Atlantic Beach State FL Zip 32233 Phone 904- 5-9198 E-Mail leffday292@gmail.com Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Owner Contractor Information Name of Company: Caudel Builders _Qualifying Agent: Jeff Caudel Address 151 College Drive#17 City Orange Park State FL Zip 32065 Office Phone 904-262-5005 Job Site/Contact Number 904-588-5602 State Certification/Registration# CGC15118090 E-Mail Jeff@caudelbuilders corn Architect Name&Phone# Engineer's Name& Phone# CR Caudel PE 904-272-5005 Workers Compensation Donovan&Abercrombie Ex 12/15/2018 Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies, or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR R NOTICE OF COMMENCEMENT. ±r t.),ALJZ (Signature of Owner o ent) , (Signature of Contractor) (including contras or) . Signed and sworn to(or affirmed) before me this 3 I day of Si ned and sworn to(or affirmed) efore me this 5—day of PSI' , ° , by 4ettCa.ucke IAARISSALORDA ��, JJJJJJ A 411 *. MY COMMI5SlON N GO 22d�45 '7 a rt S.;c, (.-o( !! r EXPIRES Jun.12,1'21 ;tfi` MISTY FLORES ',Mr:, ,Mr (i,nature of Notary) , Commission#GG 171925 Cignafif .f Notary) Bonded 11w Nelaiy ,UrdehoUra Expires January 2,2022 [ I P sonally Known OR °'Fa O31iy'1f09881mtn tfike800-385-1919 [ duced Identification -• •- . • Type of Identification: I tV< 1/5 11C t1c15 Type of Identification: 06, Y' CA(Q-Y\ _C._ k ,tsiti " "_" CITY OF ATLANTIC BEACH CO ' 800 Seminole Road Atlantic Beach,Florida 32233 REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date ' '/g//5Revision to Issued Permit Corrections to Comments Permit#Re.:-S4/ 00.23 Project Address ,29 02_ 14 <--/// get,„ ( a/ FL .3,23� Contractor/Contact Name Caz/ / & ,lderS Phone 904 -e2?2-62 Email J 4-��e Cav<dti I�iA%/dc rs - co,4 1 Cell `TO9'— S8` -- S60 Z Description of Proposed Revision/Corrections: Permit Fee Due SD. d 4642./ w r'/& SSG a l/ 1' r'/l'a.-n 5 rt, -- /JN r ^ "/ed, /P i a 140 ., 4f-v,� _ 0 r—td,4&-710./ -f-�,r rr (A/,,, COAL ��•�✓e r pef,v1. ay..ifS of ,r- ad u bet, q si GI �� �1�� a« b -� Slip Additional Increase in Building Value$ 0 Additional S.F. 9/ By signing below,I JZ (1 vizi,—( affirm the Revision is inclusive of the proposed changes. (printed name) 9 /‘//‘ Signature of Co c r/Agent(Contractor must sign if increase in valuation) Dat (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review Comments i - 0 . ment Review Required: • • I. nning &Zoning Reviewed By Tree A.ministrator Public Works �/ Public Utilities /Q_ Lj' �o/ d Public Safety Date Fire Services ` 41 ° y ,'S f CITY OF ATLANTIC BEACH j OFFICE Cwt 800 SEMINOLE ROAD op 15 ATLANTIC BEACH, FL 32233 (904) 247-5800 74J;fl9`, BUILDING REVIEW COMMENTS Date: 9/17/2018 Permit#: RESA18-0023 Site Address: 292 16TH ST Review Status: DENIED RE#: 170385 0000 Applicant: CAUDEL& ASSOCIATES LLC Property Owner: DAY JEFFREY E Email: JEFF@CAUDELBUILDERS.COM Email: jeffdav292@gmail.com Phone: 9042625005 Phone: 505-9198 THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: The RE# is missing from the permit application form. Come to office and write in the RE#. 7 elavatiois-required to show the finish floor elevation of the proposed room addition. Addition is more than 400 square feet. 2 copies of both please. 13 v'. -a1 er w `i k 1 % v o m's-1•- q r" e e ;' s-4 rizcs (3 v ld f1 s P. F. c' c o cv w...o,A f flro on S u,r v ey O(L > i -q- tr >1.„ From the 2017 FBC-Existing Building, 6th Edition, choose a method f construction & compliance/alteration level. Place information on page S0.0, under DESIGN CODE:. 2 Copies of this corrected page will be needed. Submit 2 copies of the Florida Product Approval Information Sheets that are available at the A.B. Building Department, for all components and cladding items for this job. FL#s that end in a "R” value will not be acceptable. Must be the exact number for the items to be installed. Metal roofs are planned reviewed. Please submit the FL# as well as the manufacturer's installation instructions and Engineering associated with the roof product. 2 copies. Building Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach ReUi e w C-Oer VY 'fA f N. L'rn c , /-6d 9-/ 7- I k P/ OFFICE COP )- PERMITTED OP 'PERMITTED BUILDING DATA DO NOT WRITE BELOW — OFFICE USE ONLY Applicable Codes: 6th Edition (2017) Florida Building Code DEVELOPMENT SIZE: Habitable Space (ft') 69 9 ac✓�71, Non-Habitable Space (ft2) LAND INFORMATION: Zoning District 1 3- Z Flood Zone Minimum FFE BUILDING INFORMATION: Construction Type V Occupancy Group Si-ns). l v7 Number of Stories cillo Max Occupancy Load Fire Sprinklers Required CONDITIONS/ COMMENTS: 100C(i m,114 f-ro s fry i 1Yl by /v ; t 4 p r -�v o w . P . o► 4' 2 ) r , S by ; I J l ti.S y fir Rev. 2.7.2018 Perm, ieb-Dog- oaa-3 OFFICE COPY NOTICE OF COMMENCEMENT State of Florida Tax Folio No. County of Duval To Whom It May Concern: The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being improved: 15-83 16-2S-29E. 15 ATLANTIC BEACH PARKWAY UNIT NO 02LOT 5,6(EX PT R/W)B LK7 Address of property being improved: 292 16`h Street,Atlantic Beach,FL 32233 General description of improvements:Addition Owner:Jeffrey and Diane Day Address:292 16th Street,Atlantic Beach,FL Owner's interest in site of the improvement:Owner Fee Simple Titleholder(if other than owner): Name: Contractor:Caudel Builders Address: 151 College Drive#17,Orange Park,FL 32065 Telephone No.: 904-272-5005 Fax No:904-621-9006 Surety(if any) Address: Amount of Bond$ Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: Address: Phone No: Fax No: Name of person within the State of Florida, other than himself, designated by owner upon whom notices or other documents may be served: Name: Address: Telephone No: Fax No: In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one (1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER ' ' /igned: `�� 1 Date: 31J:dy-20(8 Before me this 31 $4" day of `)'J\y in the County of Duval,State Of Florida,has personally appeared nicaNc. 1l)a y Dec#2018204112,OR BK 18508 Page 1646, Notary Public at Large,State of Florida,CRunty of Duval.„),,(10,1 AAa I I Ss`t t-o r44 Number Pages:1 4Iy commission expires: T'u>l Q. ('o'-I 2-0%O Recorded 08/29/2018 10:56 AM, Personally Known: or RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL Produced Identification: 1)ri'v t (5 t i c t KS z COUNTY RECORDING $10.00 ,gip MARIBSALORDA _,: •s,, :,. MY COMMISSION#Ge 228145_. . :11, EXPIRES:June 12,?O22 440°Y_ Bonded Thru Notary Public thwici .rs 0virl�, City of Atlantic Beach APPLICATION NUMBER ,:35 1lL' Building Department (To be assigned by the Building Department.) r r 800 Seminole Road �..,_ - Atlantic Beach, Florida 32233-5445 ��A g'6°Z•3 ' 4 ' Phone(904)247-5826 • Fax(904)247-5845 c `,.___ E-mail: building-dept@coab.us Date routed: VZ 10 City web-site: http://www.coab.us / — APPLICATION REVIEW AND TRACKING FORM Property Address: 2 t2 loth De•artment review required Yes No r Buil• Applicant: Ca-LA-de( '.BL4_( ldeAC5 Planning &Zonin Tree Administrator ciollublic Wo Project: �,b0en ( l" On, kel lockl lic U__ tilities Public Safety Fire Services Review fee $ Dept Signature j Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. 7Denied. ❑Not applicable (Circle one.) ..Comments: BUILDING >V(Je/15-e'r)ack5/ I ceeS PLANNING &ZONING e.---3 - 18 Reviewed by: Date:v TREE ADMIN. Second Review: Approved as revised. pp ❑Denied. ❑Not applicable PUBLIC WORKS Comments: . PUBLIC UTILITIES ' PUBLIC SAFETY Reviewed by: ,! -- Dater-Z I - f e FIRE SERVICES Third Review: Approved as revised. I (Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 jyL`Jf 'A CITY OF ATLANTIC BEACH �- `fit' 800 Seminole Road Jk V? Atlantic Beach,Florida 32233 -qUiil REVISION REQUEST/ CORRECTIONS TO PLAN REVIEW COMMENTS Date /0e. Revision to Issued Permit Corrections to Comments Permit#ResA/6(00.23 Project Address )9t2. /471(- S�/ A.�[a it ",� j3 G( / rl, .3.2x30 Contractor/Contact Name Ca / / AL4,der) Phone 9o(1 -02?2-�DaS Email J te��{-e. cc,„td,,_l_64,,/,/,.r S - 60,„✓1 Description of Proposed Revision/Corrections: Permit Fee Due$ $/6012-/ w:4, o q t i/'/('A.+-i s rz '4 :.( ed: lie l.s G//e,,..,)J yr M1. ora Odd a e- .2 b elm, 44 0/ s.- 4-4.,-,4 Q I o�. No f lee— 4 Kiri Additional Increase in Building Value$ V5 Additional S.F. y / By signing below,I j d+r�1 l/�7 v�CL-( affirm the Revision is inclusive of the proposed changes. (printed name) 4?//‘//6/ Signature of Cori et/r/Agent(Contractor must sign if increase in valuation) Dat (Office Use Only) Approved ( Denied Not Applicable to Department Revision/Plan Review Comments •ep• trent Review Required: ' anning &Zoning Reviewed By Tree k•ministrator Public Works Public Utilities -1- I r Public Safety Date Fire Services 1.1 "''�11l TREE & VEGETATION AFFIDAVIT FOR INTERNAL OFFICE USE ONLY City of Atlantic Beach PERMIT# td Community Development Department 800 Seminole Road Atlantic Beach,FL 32233 �°�o;; >%' (P)904-247-5800 SITE INFORMATION ADDRESS L ' 2, [ & ' l S+re ± , (A41 cc 1-1 is decYl , FL 3 ,,),33 SUBDIVISION BLOCK LOT RE# K RESIDENTIAL E COMMERCIAL ❑ OTHER APPLICANT INFORMATION NAME t) i a i t 1) Y PHONE# i(jLt [t 214 75 IF) ADDRESS 20( Z 1(o 41 5-4--reef- CELL# 9()Lt 5c., - c 96 CITY A 41 O ird- 1 (, 1))eoc h STATE r i ZIP CODE 32 2 3 3 EMAIL CU ane OLQ-./ 29 2._@ ill of I.L' oim _I OWNER ❑ LEGAL AUTHORIZED AGENT I affirm that I have reviewed the provisions of Chapter 23, "Protection of Trees and Native Vegetation", of the Municipal Code of Ordinances for the City of Atlantic Beach Florida and/or I have participated in a pre- application meeting with the Administrator of those regulations. Subsequently, I affirm that no regulated trees and no regulated vegetation will be damaged,destroyed and/or removed from the above-described property and/or adjacent properties including right-of-way. H7BY CERTIFY THAT ALL INFORMATION PROVIDED IS CORRECT:Signature of Property Owner(s)or Authorized Agent is t0r>i//t —I)1ail e. -ba ( `-f zol e) SIGNATURE OF APPLICANT / PRINT OR TYPE NAME DAT SIGNATURE OF APPLICANT(2) PRINT OR TYPE NAME DATE N Signed and sworn before me on this "I, l day of 6f-V"�E-0"16ra-iC ,,90/8 by State of t-' 4;74 Y i, c,,t= -741/ County of Det' — Identification verified: rte, ' %17 A �b \ Oath Sworn: X) Yes a ALBERT MORENO �c lir-,^'v 1�,AY A�,ib , p "� s, Notary Public-State of Florida Nota Signature • 4. • Commission el FF 239295 ! :1,,,_,.)-4,4:,'' ,,F FF :, My Comm.Expires Jun 9,201 • Commission expires 0 C/0110-424°) 7,,..P. Bonded through National Notary Assn. 04 TREE AND VEGETATION AFfI DAVIT 03.01.2018 T pl�L`\ City of Atlantic Beach APPLICATION NUMBER �� Building Department To be assigned bythe BuildingDepartment.) 1-,--3 i1 800 Seminole Road k :�,.C ItifiK_ - .._ �r Atlantic Beach, Florida 32233-5445 ' g,SA ' $ 6 OZ3 ; 3.- Phone(904)247-5826 • Fax(904)247-5845 AUG 0 /c "!J;;�0r E-mail: building-dept@coab.us 2018 Date routed: g/Z f/L O City web-site: http://www.coab.us `' i{, III APPLICATION REVIEW AND TRACKING FORM Property Address: 212 l lQ1d1 De•artment review required Yes No ( � Buil.••• Applicant: Cctut.A,el , 31A:. ldeLs ('lannin• &Zo •a. Tree Administrator Project: KI:)Orn NdHrs emodel Cublic wocos Gblic Utilitie] Public Safety • Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: IApproved. Denied. Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed b - /i//,- '4-- s : . late: f-*" .-/ve TREE ADMIN. Second Review: A roved as revised. ❑ pp I Denied. ['Not applicable PUBLIC WORKS Comments: . PUBLIC UTILITIES ' PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ['Denied. ['Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 TYP.NO.8 AGGREGATE IN OPENINGS CONCRETE PAVERS MIN.3 1/8"(80 mm)THICK CURB/EDGE RESTRAINT WITH CUT-OUTS FOR OVERFLOW DRAINAGE(CURB SHOWN) <.o .e1111.11.1111111111 000 0000 00000 p 0.;0�� BEDDING COURSE I I/2 TO 2"(40 TO 50 mm)THICK O oc�'�e 00$00�:� (TYP.NO.8 AGGREGATE) }��S••0 8.0 C).• . 4"(100 MM)THICK NO.57 STONE �O�'OO • .I v n$, OPEN-GRADED BASE • Q�OOOOO- -;..0 �� : be MIN.6"(150 MM)THICK 7070 1QoQ Q QQO 7.�:� 40'; �: NO.2 STONE SUBBASE 1 IE 11-I I 1-1 I I-I I I-I I E= I I-I 1 I- - - - OPTIONAL GEOTEXTILE ON BOTTOM AND III=1 I I=1 11=1 11-1 I I-111=1 I I�I I— — — SIDES OF OPEN-GRADED BASE SOIL SUBGRADE-ZERO SLOPE NOTES: 1. 2 3/8"(60 MM)THICK PAVERS MAY BE USED IN PEDESTRIAN APPLICATIONS. 2. NO.2 STONE SUBBASE THICKNESS VARIES WITH DESIGN. CONSULT ICPI PERMEABLE INTERLOCKING CONCRETE PAVEMENT MANUAL. CD PERMEABLE PAVEMENT WITH FULL DRAWING NO ICPI-68 EXFILTRATION TO SOIL SUBGRADE SALE NO SCALE GREE \ COLLECTIO \ MANAGE STORMWATER RUN-OFF 4X8 PERMEABLE 0# ` PRODUCT 4 DIMENSIONS THICKNESS SF PER CUBE CUBE WEIGHT PERMEABIL N'!t,'• "" EC03143 4"x8" 3-1/8" 96 3300 LBS 9.G% AQUA PAVER " . PRODUCTS DIMENSIONS THICKNESS SF PER CUBE CUBE WEIGHT PERMEABILI :''• ,• EC03145 5"x9-7/8" 3-1/8" 92 2925 LBS 8.8 a SF RIMA PRODUCT R ECO4020 DIMENSIONS 8"x8" THICKNESS 3-1/8" SF PER CUBE 99 CUBE WEIGHT PERMEABILI1 �"AI 2900 LBS 7.5%-10% OLDE TOWNE PERMEA3LE PRODUCT S DIMENSIONS THICKNESS SF PER CUBE CUBE WEIGHT PERMEABILIT EC03144 6"x4".6••x6••,6"x9" 2-3/8" 90 2350 LBS 10.5% �w TURF BLOCK aka 4 l • 4 e - 4 I 4 4 PRODUCT f DIMENSIONS THICKNESS SF PER CUBE CUBE WEIGHT PERMEABILIT\ 1 I 4 EC04040 23-518"x15-3/4" 3-1/8" 94 2200 LBS 4096 r-�. . 4X8 PERVIOUS D $ PRODUCT Y DIMENSIONS THICKNESS SF PER CUBE CUBE WEIGHT PERVIOUS PV2040E 4"x8" 2-3/8" 120 3120 LBS YES - .OLDE TOWNE PERVIOUS 01 PRODUCTS DIMENSIONS THICKNESS SF PER CUBE CUBE WEIGHT I Of PERVIOUS PV21340E 6"x4",6"x6",6"x9" 2-3/8" 124 3330 LBS YES I PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH,FLORIDA Project Name: cf re.A.,,) (., Nam .,..3fdd\--1-\&-N Permit # Project Address: q , . gat ;' t 2 3 As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide .roduct approval ma y be obtained at: www.floridabuilding.org. Category/Subcategory Manufacturer + Product Description E Limitation of Use State# Local# A.EXTERIOR DOORS 1. Swinging �he.�ma�cw SornrAn ctcar e*-f oc d oc f K-1,42410- RA 2. Sliding 3. Sectional 4. Roll up 5.Automatic 6. Other B.WINDOWS 1. Single hung 2.Horizontal slider 3. Casement _. _ .. 4.Double hung 5.Fixed 6. Awning 4 7. Pass-through - 8.Projected 9. Mullion 10. Wind breaker 11. Dual action f t _12. Other _ - -- - - Category/Subcategory I Manufacturer 'Product Description 1Limitation of Use State# Local# C. PANEL WALL 1. Siding t1e. "c rc .`P1c11W-. ' mood \.3 q2 . 2. Soffits �. \ 3. EIFS ter. , s 4. Storefronts tp 5. Curtain walls 6. Wall louvers 7. Glass block ' 8. Membrane 9. Greenhouse 10. Synthetic stucco 11. Other r- D. ROOFING PRODUCTS 1. Asphalt shingles 2. Underlayments we.4-1,s ay tril ?NAG fca 112.6 V-057-Ito 3. Roofing fasteners 4.Nonstructural metal roof Aug" Kitivbrur -' 5. Built-up roofing '-'�---- 6. Modified bitumen 7. Single ply roofing 8. Roofing tiles 9. Roofing insulation ' 10. Waterproofing4 11. Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14. Cement-adhesive coats 15. Roof tile adhesive 16. Spray applied polyurethane v roof 1 I 17. Other Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# E. SHUTTERS 1. Accordion ---- 2. Bahama 3. Storm panels 4. Colonial 5. Roll-up ! 1 6. Equipment 7. Other F. STRUCTURAL COMPONENTS 1. Wood connector/anchor M "v� •V\a. s� 2. Truss plates ` `f 3. Engineered lumber 4. Railing 5. Coolers-freezers 6. Concrete admixtures � 7. Material __-___--- 8. Insulation forms 9. Plastics 10. Deck-roof 11. Wall 12. Sheds13. Other G. SKYLIGHTS t 1. Skylight __ .. +- _ a , Category/Subcategory Manufacturer 1 Product Description !Limitation of Use State# Local# H.NEW EXTERIOR ENVELOPE PRODUCTS • 2. ... In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. (Contractor Name) (Print Name) Signature) Company Name: (�e c� Conde.' Mailing Address: 15 1, Csj 1,t_c)z., D( \ V City: OviCkn9 State: Zip Code: .32® 5 Telephone Number: (901A) a-1 a • 5c)c)5 Fax Number: (CA ) 1p.\ • rico(v Cell Phone Number: ((ICA ) 5z3a, 5(00a E-mail Address:')e_f , Cc dth ,j,`dex5 Cf2.1,,Y1 Building Permit Application Updated12/8/17 e City of Atlantic Beach 800 Seminole Road,Atlantic Beach,FL 32233 Phone:(904)247-5826 Fax:(904)247-5845 (� p� p Job Address: 292 16th Street,Atlantic Beach,FL 32233 Permit Number: l�-ES 1 i fC� —061. Legal Description 15-83 16-2S-29E.15 ATLANTIC BEACH PARKWAY UNIT NO 02LOT 5,6(EX PT RAM B LK RE# Valuation of Work(Replacement Cost)$'15 00 O Heated/Cooled SF 1754 Non-Heated/Cooled 730 • Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): Commercial Residential • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: Addition R_oOM c.__akc c l o�(z-z)nn Florida Product Approval# for multiple products use product approval form Property Owner Information Name: Jeffrey and Diane Day Address: 262 16th Street City Atlantic Beach State FL Zip 32233 Phone 904-505-9198 E-Mail jeffday292@gmail.com Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Owner Contractor Information Name of Company: Caudel Builders Qualifying Agent: Jeff Caudal Address 151 College Drive#17 City orange Park State FL Zip 32065 Office Phone 904-262-5005 - Job Site/Contact Number 904-588-5602 State Certification/Registration# CGC15118090 E-Mail jeff@caudelbuilders corn Architect Name& Phone# Engineer's Name&Phone# -CR Caudel PE 90.4-272-5005 Workers Compensation Donovan E.Abercrombie Ex 12/15/2018 Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies, or federal agencies. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. (Signature ignature of Owner o ent) (Signature of Contractor) (including contras or) St Signed and sworn to(or affirmed)before me this 31 day of Si ned and sworn to(or affirmed)/before me this - day of ,ne_ bot ASN ?019 ,by 4e+ C MAftI$$A LORDA 1 4 A 4. EXPIRES:A(412 7 '�latary) C--o(C 5�""^'4 , MISTYFLORES I > r ( gnature of Notary) ..?• ••ti•: ( igna u -•.f Notary) &moodllw�WaryFtbec Ur4.44.1 .; ,•+ Commission#GG 171925 Expires January 2,2022 [ [ Pyrsonally Known OR lifdraddtiu 800-385.7019 [ Produced Identification ••. -• •- • 1•�� Type of Identification: b f 1 v Z V J Uri 11 C c 5 2 Type of Identification: ► 1,l?e h'-' 01..mfir, City of Atlantic Beach APPLICATION NUMBER d itt , Building Department (To be assigned by the Building Department.) r • ' A -ie, 800 Seminole Road -_,. r Atlantic Beach, Florida 32233-5445 1265 A I$' 013 l" '' Phone(904)247-5826 • Fax(904)247-5845AUG 3 /c `� p@ p U 2013 Date routed: V z`t L O "�J;if�' E-mail:Email: buildin de t coab.us / City web-site: http://www.coab.us — isYL. to' APPLICATION REVIEW AND TRACKING FORM Property Address: 2 I2. ` leth _ De.artment review required Yes No ( � Bull.'••- Applicant: CQ,(,l,Qel �( lt� Plannin• &Zo 'is r II L Tree Administrator Project: �,bcm > kli-f rertocLeI cWo Gblic Utilities Public Safety Fire Services Review fee $ Dept Signature f Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: I 'Approved. I 'Denied. I of applicable (Circle one.) Comments: /P/ /?— y/ BUILDING / PLANNING &ZONING Reviewed by: 7Z- c...1-,--- Date: 9—A/ S TREE ADMIN. / Second Review: ['Approved as revised. I (Denied. ❑Not applicable PUBLIC WORKS Comments: . PUBLIC UTILITIES ' PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ['Approved as revised. I 'Denied. [—Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 TILL COPY PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH.FLORIDA Project Name:: ie-t-iPermit #R f/8 C Q 3 // r �n Project Address: .26 ,;2 /b 4 ' S+/e• f f/-1-71- (A#4•`4- (.54a C ll. / t-r L 3713 As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product a..roval ma be obtained at:www.floridabuildin_.or_. Category/Subcategory Manufacturer Product Description Limitation of Use State# Local # A.EXTERIOR DOORS 1. Swinging 46" '1 r f`/c.i ch �„orx-tef,o r C140/ fel 76 40. r 2. Sliding 3. Sectional 4.Roll up 5.Automatic 6. Other B.WINDOWS 1. Single hung v,,/ v. tio.,/ i:�a..,+ c.704. 2.Horizontal slider 3. Casement 4.Double hung 5.Fixed 6.Awning 7.Pass-through 8.Projected 9.Mullion 10. Wind breaker . 11.Dual action 12. Other Category/Subcategory Manufacturer Product Description imitation of Use i State# Local# C.PANEL WALL _.. .... 1. Siding Loo S�� ' EX4% or d.� 1314,2 2. Soffits Ga.•� if .-� U SF/ ?3 T.5,2_; 3.EIFS Y / 4. Storefronts 5. Curtain walls 6. Wall louvers 7. Glass block 8.Membrane a 9. Greenhouse 10. Synthetic stucco 11. Other D.ROOFING PRODUCTS 1.Asphalt shingles 2.Underlayments Ow it� RI,:io (2.4 Gro s 4: 61.E FL/4214 3.Roofing fasteners 4.Nonstructural metal roof (:‘•‘•/j 1e4- I RQat- 116Kri 5.Built-up roofing 6.Modified bitumen 7. Single ply roofing 8.Roofing tiles 9.Roofin_ insulation 10. Waterproofing I 11. Wood shingles/shakes 12. Roofing slate 13.Liquid applied roofing 14. Cement-adhesive coats 15.Roof tile adhesive_ 16. Spray applied polyurethane roof 17. Other Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# E. SHUTTERS 1.Accordion 2.Bahama 3. Storm panels 4. Colonial 5.Roll-up 6.Equipment 7. Other F. STRUCTURAL COMPONENTS 1. Wood connector/anchor ,) n 2. Truss plates 3.Engineered lumber 4.Railing 5. Coolers-freezers 6. Concrete admixtures 7.Material 8. Insulation forms 9.Plastics 10.Deck-roof 11. Wall 12. Sheds 13. Other G. SKYLIGHTS 1. Skylight 1 2. Other Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# H. NEW EXTERIOR ENVELOPE PRODUCTS 1. 2. In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. (Contractor Name) (Print Name) (Signature) i Company Name: Caved S,,.; ele _s Mailing Address: �5 1 �� a7 City: 10(a,t) arL State: FL Zip Code: _g_2v‘s- Telephone Number: (90 ) .272'SOD. Fax Number: (90-f ) ‘,2/ -9d0‘ Cell Phone Number: (90{ ) j gir-S1)©,-•-• E-mail Address: 1L# c�°i C ct u de-0z ldecS C o . VNNIFIrrn\ FLORIDA PRODUCT APPROVAL Gulf SUPPLY & rr,i. . , ,'L , ,- IIGULFP ! 'TM,, . .. ,„ ,... „. , .44.0) III i 26 GUAGE GULFRIBTM PANEL OVER 15/32" PLYWOOD FLORIDA PRODUCT APPROVAL NO. 11651.22 R2 Product Evaluation Report GULF COAST SUPPLY& MANUFACTURING, LLC. 26 Ga. GulfRibTM Roof Panel over 15/32" Plywood Florida Product Approval #11651.22 R2 Florida Building Code 2014 Per Rule 61G20-3 Method: 1 -D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G300,0111,,, 00 A\EL S. k!',,,, Newberry, FL 32669 ; op,:••• • ' y , �,\GENS• '1, Engineer Evaluator: _ :F.*:� NO 7559 . Dan Kuhn, P.E. #75519 .- * � �'�— Florida Evaluation ANE ID: 10743 ;%. STATE OF .•12"Z :Fs;LT•.`• ORIDr-.•'\*6 : Validator: ',",CONAL ENG\'‘` Locke Bowden, P.E. #49704 ",1 o t- 9450 Alysbury Place o.00/20/5 Montgomery, AL 36117 Contents: Evaluation Report Pages 1 - 5 FL# 11651.22 R2•JUNE 15,2015 PRODUCT EVALUATION REPORT J KUHN ENGINEERING, LLC 11670 ISLAND LAKES LANE,BOCA RATON,FL 33498• FL COA#30464 "'Niro\ FLORIDA PRODUCT APPROVAL GulfCoast SUPPLY & MANUFACTURING GULF .A ,„,,,' . Isia' L 26 GUAGE GULFRIBTM PANEL OVER 15/32" PLYWOOD FLORIDA PRODUCT APPROVAL NO. 11651.22 R2 TM Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Product Description: GulfRibTM' 3/4" Rib Roof Panel, Minimum 26 Ga. Steel, 36" Coverage, through fastened roof panel over minimum 15/32" Plywood Decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2014 Section 1507.4.3. Paint Finish Optional Yield Strength: Min. 80.0ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2014, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 36" Coverage Rib Height: 3/4" Major Rib at 9" O.C. Panel Fastener: #9-15x1.5" HWH with sealing washing or approved equal 1/4" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4 Substrate Description: Minimum 15/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/Florida Building Code 2014. Design Uplift Pressures: Table "A" Maximum Total Uplift Design Pressure 69.25 psf 159.25134 Fastener Pattern 9"-9"-9"-9" 6.5"-2.5"-6.5"- 2.5"6.5"-2.5"-6.5" `.stener Pattern Spacing; Design Pressure includes a Safety Factor= 2.0. FL# 11651.22 R2•JUNE 15,2015 PRODUCT EVALUATION REPORT J KUHN ENGINEERING, LLC 11670 ISLAND LAKES LANE,BOCA RATON, FL 33498 • FL COA#30464 , "'Num ,:_, i, .,. FLORIDA PRODUCT APPROVAL Gulf Coast SUPPLY & MANUFACTURING 1111 GULF! M fore t~: 26 GUAGE GULFRIBTM PANEL OVER 15/32" PLYWOOD FLORIDA PRODUCT APPROVAL NO. 11651.22 R2 Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2014, as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06 -Test for Uplift Resistance of Roof Assemblies • UL 1897-04- Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94/ 1897-98 Uplift Test Force Engineering &Testing, Inc. (FBC Organization #TST-5328) Report No. 117-0062T-07A, B, Dated 02/19/2007 2. Certificate of Independence By Dan Kuhn, P.E. (FL# 75519)I@ Kuhn Engineering, LLC (FBC Organization #ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005(3)for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2014, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2014 section 1507.4.5.1 and 1507.4.5.2. FL# 11651.22 R2•JUNE 15,2015 PRODUCT EVALUATION REPORT D. KUHN ENGINEERING, LLC 11670 ISLAND LAKES LANE, BOCA RATON,FL 33498•FL COA#30464 7.4NIFIC\ FLORIDA PRODUCT APPROVAL GulfCoast - SUPPLY & MANUFACTURING IIGULFR ! ! TM lit 26 GUAGE GULFRIBTM PANEL OVER 15/32" PLYWOOD FLORIDA PRODUCT APPROVAL NO. 11651.22 R2 Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL# 11651.22 R2•JUNE 15,2015 PRODUCT EVALUATION REPORT IKUHN ENGINEERING, LLC 11670 ISLAND LAKES LANE,BOCA RATON,FL 33498• FL COA#30464 F ' /.'411141111K` e ENGINEER'S LOAD TABLE SPEC GulfCoast SUPPLY & MANUFACTURING GULF! ! ' !'TM 26 GUAGE GULFRIBTM PANEL OVER 15/32" PLYWOOD 11141;iii) FLORIDA PRODUCT APPROVAL NO. 11651.22 R2 ciiiii____ G TM ENGINEER LOAD TABLE: 26 Ga. GulfRibTM Panel over 15/32" Plywood Buildings having a Roof Mean Height <_ 20'-0"; '1tiv:`F"• ' 12"/12" Gable or Hip Roof; Wind Speeds 120- '`" 180mph, Exposure C, Risk Category 11,,Enclosed Building, based on Florida Bulldind Co er,2014. , 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE SPEED .(MIN.1/4" (MIN15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER Penetration) SPACING SPACING SPACING SPACING SPACING SPACING SPACING ZONE 2 #9-15x1.5" Plywood 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 12",TYPE 2 1.)PANEL DESCRIPTION:GULFRIBTM, MIN. 26 GA., GRADE 80, 36"COVERAGE, 3/4" TALL. 2.)PANEL FASTENER: #9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL 3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: 69.25 PSF @ 24" O.C. FASTENER SPACING TYPE I FASTENER PATTERN, 159.25 PSF @ 12" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.) PLYWOOD DECKING: MIN.15/32" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2014. 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85)MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2014 HIP ROOF a Note: Dimension(a)is defined as 10%of the minimum width of the building or IZONE2 ZONE 3 40% of the mean height of the roof,whichever is smaller,however,(a)cannot be !' ,\ a :a less than either 4%of the minimum width of the building or 3 feet. TYPE 1 FASTENER PATTERN RIDGE 1 1 9" 1 1 At Panel Lap-, ZONE 1 Cord.Tape Seal for use on Slopes less than 3:12-1 (1)*9-15 x 1-1/2'w/Sealer Washer @ 24'O.C.Max. —EAVE ZONE 2 a TYPE 2 FASTENER PATTERN GABLE ROOF 6.5" i 2.5"76.5"-12.51-6.5" 2.51-6.5'12.5"- --. , 1 . i \ //—RIDGE .5" 6 5 2 5 \ -RIDGE L Cont.Tape Seal for use on Slopes less than 3:12-1 / l (1)*9-15 x 1-1/2'w/Sealer Washer @ 12'O.C.Max. I A ;a + _,a ZONE 1 I 1 4 -ZONE 3 `EAVE FL# 11651.22 R2•JUNE 15,2015 PRODUCT EVALUATION REPORT IKUHN ENGINEERING, LLC 11670 ISLAND LAKES LANE,BOCA RATON,FL 33498 • FL COA#30464 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Day Addition Builder Name: Caudel Builders Street: 292 16th Street Permit Office: Duval City,State,Zip: Jacksonville,FL,32233 Permit Number: Owner: Jeff and Diane Day Jurisdiction: Design Location: FL,Jacksonville County: Duval(Florida Climate Zone 2) 1. New construction or existing Addition 9. Wall Types(650.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 410.67 ft' b.Frame-Wood,Adjacent R=11.0 240.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms(Bedrms In Addition) 1(1) d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (647.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 647.00 ft2 6. Conditioned floor area above grade(ft2) 647 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(80.7 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Remodeled Space 8 35 a. U-Factor: Dbl,U=0.32 80.67 ft2 SHGC: SHGC=0.19 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 7.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 7.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 6.298 ft. Area Weighted Average SHGC: 0.190 14.Hot water systems-Replacement equipment a.Propane Tankless Cap: 1 gallons i 8. Floor Types (647.0 sqft.) Insulation Area EF:0.820 a.Slab-On-Grade Edge Insulation R=0.0 647.00 ft2 b. Conservation features b.N/A R= ft2 None c. N/A R= ft2 15.Credits CF, Pstat Glass/Floor Area: 0.125 Total Proposed Modified Loads: 16.48 PASS Total Baseline Loads: 16.53 y I hereby certify that the plans and specifications covered by Review of the plans and r:, ,tHE STgT'y. this calculation are in compliance with the Florida Energy specifications covered by thisa.�-�dP;- a- y Code. calculation indicates compliance 4 -6,, ", with the Florida Energy Code. '.1,/,„c,,,',', .:-:-..!;;,4.',',',..,;'",, p PREPARED BY: Mike Chrnura Before construction is completed 1 w ' .;-*-1,t''. .-1,'° DATE: 8/21/18 1 cc- 0 - --- _ this building will be inspected for a �. s �� �,,__ compliance with Section 553.908 , if„ I hereby certify that this building,as designed,is in c• pliance Florida Statutes. ''. ' S i r with the Florida EnergyCo.- r C )yVEI3�� ^�,CU tti��u� OWNER/AGENT: _ / '/y� BUILDING OFFICIAL: N1 DATE: _ / ••. ,.f�1 I DATE: I - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 8/21/2018 8:21 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Day Addition Bedrooms: 1 Address Type: Street Address Building Type: User Conditioned Area: 647 Lot# Owner Name: Jeff and Diane Day Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Caudel Builders Rotate Angle: 0 Street: 292 16th Street Permit Office: Duval Cross Ventilation: County: Duval Jurisdiction: Whole House Fan: City,State,Zip: Jacksonville, Family Type: Single-family FL, 32233 New/Existing: Addition Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE INT 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block1 647 5176 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Addition 372 2976 No 1 1 1 Yes Yes Yes 2 Remodeled Space 275 2200 No 0 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Addition 38 ft 0 372 ft2 ____ 0.3 0.3 0.4 2 Slab-On-Grade Edge lnsulatio Remodeled Spec 12.67 ft 0 275 ft2 ____ 0.3 0.3 0.4 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch �/ # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or shed Metal 682 ft2 108 ft2 Medium N 0.96 No 0.9 No 0 18.4 V ATTIC # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 647 ft2 N N 8/21/2018 8:21 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING _l_ 4 Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Addition 30 Batt 372 ft2 0.11 Wood 2 Under Attic(Vented) Remodeled Spac 30 Batt 275 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below it Omt Tn Wall Type Space R-Value Ft In Ft In Area R-Vahia Fraction Ahsor_Grade% 1 N Garage Frame-Wood Addition 11 18 4 8 146.7 ft2 0.23 0.75 0 2 S Exterior Frame-Wood Addition 11 18 4 8 146.7 ft' 0.23 0.75 0 3 E Exterior Frame-Wood Addition 11 20 4 8 162.7 ft2 0.23 0.75 0 4 N Exterior Frame-Wood Remodeled S 11 12 8 8 101.3 ft2 0.23 0.75 0 5 E Garage Frame-Wood Remodeled S 11 11 8 8 93.3 ft2 0.23 0.75 0 DOORS V 4 Ornt Door Type Space Storms U-Value Width Height Area --- -- Ft In Ft In 1 N Insulated Remodeled S None .46 2 4 6 8 15.6 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 2 Vinyl Low-E Double Yes 0.32 0.19 N 40.0 ft2 8 ft 8 in 2 ft 0 in None None 2 E 3 Vinyl Low-E Double Yes 0.32 0.19 N 24.0 ft2 1 ft 2 in 2 ft 0 in None None 3 N 4 Vinyl Low-E Double Yes 0.32 0.19 N 16.7 ft2 8 ft 0 in 2 ft 0 in None None GARAGE L # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 386.9089 ft2 386.9089 ft2 39 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 603.9 33.15 62.35 .1339 7 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/Existing/c Split HSPF:8.2 7 kBtu/hr 1 sys#1 8/21/2018 8:21 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM V # System Type Subtype - Efficiency Capacity Air Flow SHR Block Ducts 1 Central UniUExisting/confirme Split SEER: 14 7 kBtu/hr 210 cfm 0.75 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane Tankless Exterior 0.82 1 gal 40 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ---Supply---- Return--- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 8 35 ft2 Attic 20 ft2 Default Leakage Remodeled (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar A r Ma Jun �]Jul Aug Sep Oct Nov Dec HeatinX Jan X Feb X Mar Apr f Maf Jun 4 1 Jul 4 Aug Sep Oct ..x: Nov X Dec VentingJan Feb X Mar X Apr [ May [ Jun [ J Jul [ JJ Aug Sep X Oct )C Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 Addition Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 Remodeled Space 8/21/2018 8:21 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or,addition 1. Addition 12. Ducts,location&insulation level a)Supply ducts R 8.0 2. Single-family or multiple-family 2. Single-family b)Return ducts R 8.0 c)AHU location Remodeled Space 3. No. of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 1 13. Cooling system: Capacity 7.0 a)Split system SEER 14.0 5. Is this a worst case?(yes/no) 5. No b)Single package SEER c)Ground/water source SEER/COP 6.Conditioned floor area(sq.ft.) 6. 647 d)Room unit/PTAC EER e)Other 7. Windows,type and area a)U-factor:(weighted average) 7a. 0.320 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.190 14. Heating system: Capacity 7.0 c)Area 7c. 80.7 a)Split system heat pump HSPF 8.2 b)Single package heat pump HSPF 8. Skylights c)Electric resistance COP a)U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other 9. Floor type, insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood, raised (R-value) 9b. 15. Water heating system c)Concrete,raised (R-value) 9c. a)Electric resistance EF b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF 0.82 A. Exterior: d)Solar system with tank EF 1.Wood frame (Insulation R-value) 10A1. 11.0 e)Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. f)Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry(Insulation R-value) 1062. 16. HVAC credits claimed(Performance Method) 11. Ceiling type and insulation level a)Ceiling fans Yes a)Under attic 11a. 30.0 b)Cross ventilation No b)Single assembly 11b. c)Whole house fan No c)Knee walls/skylight walls 11c. d)Multizone cooling credit d)Radiant barrier installed 11d. No e)Multizone heating credit f)Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed (or exceeded)in this home before final inspection. Otherwise,a new EPL display card will be completed based on installed code compliant features. Builder Signature: . // r_ % Date: 00/ Address of New Home: 292 16th Street City/FL Zip: Jacksonville, FL 32233 8/21/2018 8:22:15 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 292 16th Street Permit Number: Jacksonville, FL,32233 MANDATORY REQUIREMENTS See individual code sections for full details. V SECTION R401 GENERAL R401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal enveloplee building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. LR402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3. Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. ❑ R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 L/s/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 8/21/2018 8:22 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) ❑R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. ❑R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. ❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or (7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. ❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. ❑ R403.3.3 Duct testing(Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3. ❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. ❑ R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. ❑ R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. ❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 8/21/2018 8:22 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) • R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3%inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies(Mandatory). R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). ❑ R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of combustion types of service water-heating systems to be turned off. R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. • R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation including:Natural,Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10 otherwise. R403.7 Heating and cooling equipment(Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMUM (CFM) (CFM/WATT) (CFM) Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom,utility room 10 1.4 cfm/watt <90 Bathroom,utility room 90 2.8 cfm/watt Any For SI: 1 cfm=28.3 L/min. a. When tested in accordance with HVI Standard 916 8/21/2018 8:22 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) ❑ R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in • Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. ❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. ❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. ❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. ❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections ❑ C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. ❑ R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8°C). D R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. ❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. ❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. ❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal ❑ efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 8/21/2018 8:22 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. ❑ R403.11 Portable spas(Mandatory)he energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS ❑ R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception:Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory).Fuel gas lighting systems shall not have continuously burning pilot lights. 8/21/2018 8:22 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 5 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit#: Job Information Builder: Caudel Builders Community: Lot: NA Address: 292 16th Street City: Jacksonville State: FL Zip: 32233 Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ER!Method O PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 Pascals)in Climate Zones 1 and 2. O PERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH(50)value,as shown on Form R405-2017(Performance)or R406-2017(ERI),section labeled as infiltration,sub-section ACH50. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ER!): 7.000 x 60 _ 5176 = Method for calculating building volume: CFM(50) Building Volume ACH(50) 0 Retrieved from architectural plans PASS `Code software calculated When ACH(50)is less than 3, Mechanical Ventilation installation 0 Field measured and calculated must be verified by building department. R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3. Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 8/21/2018 8:22:42 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Day Addition Builder Name: Caudel Builders Street: 292 16th Street Permit Office: Duval City,State,Zip: Jacksonville,FL,32233 Permit Number: Owner: Jeff and Diane Day Jurisdiction: w Design Location: FL,Jacksonville V COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealin material. requirements Breaks or joints in the air barrier shall be sealed. 9 The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in anydroppedceiling/soffit the insulation and any gaps in the air barrier shall be sealed. ceein /soffit shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spams. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 8/21/2018 8:22 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 1 Building Input Summary Report PROJECT Title: Day Addition Address type: S Building Type: User Bedrooms: 1 Lot#: Owner: Jeff and Diane Day Conditioned Area: 647 Block/SubDivision: Total Stories: 1 PlatBook: Builder Name: Caudel Builders Worst Case: No Street: 292 16th Street Permit Office: Duval Rotate Angle: 0 County: Duval Jurisdiction: Cross Ventilation: City,State,Zip: Jacksonville, Family Type: Single-family Whole House Fan: FL,32233 New/Existing: Addition Terrain: Suburban Year Construct: 2018 Shielding: Suburban Comment: CLIMATE V /Design Design Temp Int Design Temp Heating Design Daily temp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INTL_A 32 93 70 75 1281 49 Medium UTILITY Fuel Unit Utility Name Monthly Fixed Cost $/Unit Electricity kWh EnergyGauge Default 0.00 0.11 Natural Gas Therm EnergyGauge Default 0.00 0.68 Fuel Oil Gallon EnergyGauge Default 0.00 1.10 Propane Gallon EnergyGauge Default 0.00 1.40 SURROUNDINGS ----------Shade Trees--------- -------Adjacent Buildings-------- Ornt Type Height Width Distance Exist Height Width Distance N None Oft Oft Oft Oft Oft Oft NE None Oft Oft Oft Oft Oft Oft E None Oft Oft Oft Oft Oft Oft SE None Oft Oft Oft Oft Oft Oft S None Oft Oft Oft Oft Oft Oft SW None Oft Oft Oft Oft Oft Oft W None Oft Oft Oft Oft Oft Oft NW None Oft Oft Oft Oft Oft Oft BLOCKS ✓Number Name Area Volume 1 Block1 647 5176 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated _1 Addition 372 2976 No 1 1 Yes Yes Yes 2 Remodeled Space 275 2200 No 0 0 Yes Yes Yes 8/21/2018 8:25:20 PM EnergyGauge®/USRCZB v6.1 Page 1 Building Input Summary Report FLOORS (Total Exposed Area = 647 sq.ft.) V# Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet _1 Slab-On-Grade Edge Ins Addition 38 0 372 ft 0.587 - 0.3 0.3 0.4 _2 Slab-On-Grade Edge Ins Remodeled Space 12.67 0 275 ft 0.587 -- 0.3 0.3 0.4 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch \/# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or shed Metal 682 ft2 108 ft2 Medium N 0.96 No 0.9 No 0 18.4 ATTIC ✓# Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 647 ft2 N N CEILING (Total Exposed Area = 647 sq.ft.) ✓# Ceiling Type Space R-Value Ins.Type Area U-Factor Framing Frac. Truss Type _1 UnderAttic(Vented) Addition 30.0 Batt 372.0ft2 0.044 0.11 Wood _2 UnderAttic(Vented) Remodeled Space 30.0 Batt 275.002 0.044 0.11 Wood WALLS (Total Exposed Area = 651 sq.ft.) Adjacent Cavity Width Height Area U- Sheath Frm. Solar Below V# Omt To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade _1 N Garage Frame-Wood Addition 11.0 18.0 4 8.0 0 146.7 0.101 0.23 0.75 0% _2 S Exterior Frame-Wood Addition 11.0 18.0 4 8.0 0 146.7 0.101 0.23 0.75 0 _3 E Exterior Frame-Wood Addition 11.0 20.0 4 8.0 0 162.7 0.101 0.23 0.75 0% _4 N Exterior Frame-Wood Remodeled Space 11.0 12.0 8 8.0 0 101.3 0.101 0.23 0.75 0 5 E Garage Frame-Wood Remodeled Space 11.0 11.0 8 8.0 0 93.3 0.101 0.23 0.75 0% DOORS (Total Exposed Area = 16 sq.ft.) Width Height # Ornt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area 1 N Exterior Insulated Remodeled Space None 0.46 2.00 4 6.00 8 15.6ft2 WINDOWS (Total Exposed Area = 81 sq.ft.) Wall ---Overhang---- V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening _1 S 2 Vinyl Low-E Double Yes 0.32 0.19 N N 40.0ft2 8.0 ft 8 in 2.0 ft 0 in None None 2 E 3 Vinyl Low-E Double Yes 0.32 0.19 N N 24.0ft2 1.0 ft 2 in 2.0 ft 0 in None None 3 N 4 Vinyl Low-E Double Yes 0.32 0.19 N N 16.7ft2 8.0 ft 0 in 2.0 ft 0 in None None INFILTRATION ✓# Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 8/21/2018 8:25:20 PM EnergyGauge®/USRCZB v6.1 Page 2 • Building Input Summary Report INFILTRATION(Continued) _1 Wholehouse Proposed ACH(50) 0.00036 604 33.15 62.35 0.1339 7.0 All GARAGE ✓# Floor Area Roof Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 387 ft2 387 ft2 39 ft 8 ft 1 MASS V# Mass Type Area Thickness Furniture Fraction Space _1 Default(8 lbs/sq.ft.) 0 ft2 0 ft 0.30 Addition 2 Default(8 Ibs/sq.ft.) 0 ft2 0 ft 0.30 Remodeled Space HEATING SYSTEM V# System Type/FI.Addition Subtype AHRI# Efficiency Capacity —Geothermal HeatPump— Ducts Block kBtu/hr Entry Power Volt Current 1 Electric Heat Pump/Existing/co Split HSPF:8.20 7.0 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM ✓# System Type/FI.Addition Subtype AHRI# Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm 1 Central Unit/Existing/co Split SEER:14 7.0 210 0.75 sys#1 1 HOT WATER SYSTEM ✓# System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length 1 Propane Tankless Exterior 0.82(0.82) 1.00 gal 40 gal 120 deg Standard =>R-3 150 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff 1 No NA NA NA No NA NA NA None DUCTS Duct -------Supply------- --------Return - Air CFM 25 CFM 25 HVAC# V # Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 8.0 35 ft2 Attic 8.0 20 ft2 Default Leakage Remodeled (Default)(Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans:N Cooling []Jan []Feb []Mar []Apr []May [X]Jun [X]Jul [X]Aug [X]Sep []Oct []Nov []Dec Heating [X]Jan [X]Feb [X]Mar []Apr []May []Jun []Jul []Aug []Sep []Oct [X]Nov [X]Dec Venting []Jan []Feb [X]Mar [X]Apr []May []Jun []Jul []Aug []Sep [X]Oct [X]Nov []Dec 8/21/2018 8:25:21 PM EnergyGauge®/USRCZB v6.1 Page 3 Building Input Summary Report TEMPERATURES(Continued) V/ Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 HARD WIRED LIGHTING VD Type Screen Location Total# Quantity# Comp Fl All Other H Bulb Type Schedule Watts per bulb 1 Hard-Wired Default Exterior 20 2 HERS2011 60 2 Hard-Wired Default Garage 20 2 HERS2011 60 MISC ELECTRICAL LOADS VD Type Screen Location Item Quantity Catagory Operating Schedule Off Standby 1 Misc Elec Load Simple Default Main 1 1 HERS2011 1 VERIFIERS Name Task James Browne Blower Door Test Frances Smith-Warren Duct Test Jerry Cunningham Ventilation Test James Browne Pressure Mapping APPLIANCES & LIGHTING SCHEDULES Appliance Schedule: HERS2014 Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Occupancy peak: 400 Btu AM 0.930 0.930 0.930 0.930 0.930 0.930 0.930 0.980 0.460 0.270 0.270 0.270 %Released: 100 % PM 0.270 0.270 0.270 0.270 0.330 0.610 1.000 1.000 0.930 0.930 0.930 0.930 refrig peak: 0 W AM 0.824 0.804 0.784 0.764 0.744 0.734 0.744 0.754 0.764 0.794 0.814 0.854 %Released: 100 % PM 0.854 0.864 0.884 0.904 0.925 0.945 0.925 0.915 0.904 0.894 0.874 0.854 cWash peak: 0 W AM 0.200 0.100 0.050 0.050 0.050 0.075 0.200 0.375 0.500 0.800 0.950 1.000 Released: 30 % PM 0.875 0.850 0.800 0.625 0.625 0.600 0.575 0.550 0.625 0.700 0.650 0.375 E-cDry peak: 0 W AM 0.200 0.100 0.050 0.050 0.050 0.075 0.200 0.375 0.500 0.800 0.950 1.000 %Released: 15 % PM 0.875 0.850 0.800 0.625 0.625 0.600 0.575 0.550 0.625 0.700 0.650 0.375 dWash peak: 0 W AM 0.139 0.050 0.028 0.024 0.029 0.090 0.169 0.303 0.541 0.594 0.502 0.443 %Released: 60 % PM 0.376 0.396 0.334 0.323 0.344 0.448 0.791 1.000 0.800 0.597 0.383 0.281 E-rOven peak: 0 W AM 0.057 0.057 0.057 0.057 0.057 0.114 0.171 0.286 0.343 0.343 0.343 0.400 %Released: 80 % PM 0.457 0.343 0.286 0.400 0.571 1.000 0.857 0.429 0.286 0.229 0.171 0.114 8/21/2018 8:25:21 PM EnergyGauge®/USRCZB v6.1 Page 4 Building Input Summary Report APPLIANCES & LIGHTING SCHEDULES(Continued) TVs peak: 176 W AM 0.100 0.050 0.050 0.050 0.100 0.200 0.400 0.450 0.400 0.200 0.100 0.100 %Released: 100 % PM 0.050 0.050 0.150 0.450 0.850 1.000 0.950 0.800 0.500 0.250 0.150 0.100 cFan peak: 0 W AM 0.600 0.600 0.600 0.600 0.600 0.600 0.600 0.250 0.250 0.250 0.250 0.250 %Released: 100 % PM 0.250 0.250 0.250 0.250 0.250 0.250 0.550 0.600 0.600 0.600 0.600 0.600 Igts-in peak: 0 W AM 0.160 0.150 0.160 0.180 0.230 0.450 0.420 0.260 0.190 0.160 0.120 0.110 %Released: 100 % PM 0.160 0.170 0.250 0.270 0.340 0.550 0.600 0.880 1.000 0.880 0.510 0.280 Igts-out peak: 35 W AM 1.000 1.000 1.000 1.000 1.000 0.750 0.750 0.000 0.000 0.000 0.000 0.000 %Released: 0 % PM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.500 0.750 0.750 0.750 1.000 Igts-gar peak: 37 W AM 0.000 0.000 0.000 0.000 0.000 0.500 0.750 1.000 0.750 0.500 0.000 0.000 %Released: 0 % PM 0.000 0.000 0.500 0.500 0.750 1.000 0.750 0.500 0.000 0.000 0.000 0.000 MEL peak: 0 W AM 0.500 0.500 0.500 0.750 0.750 0.850 1.000 1.000 1.000 1.000 0.900 0.900 %Released: 90 % PM 0.900 0.900 1.000 1.000 1.000 1.000 1.000 1.000 1.000 0.850 0.750 0.750 8/21/2018 8:25:21 PM EnergyGauge®/USRCZB v6.1 Page 5 Residential System Sizing Calculation Summary Jeff and Diane Day Project Title: 292 16th Street Day Addition Jacksonville, FL 32233 8/21/2018 Location for weather data: Jacksonville, FL -Defaults: Latitude(30.5) Altitude(30 ft.) Temp Range(M) Humidity data: Interior RH (50%) Outdoor wet bulb(77F) Humidity difference(49gr.) Winter design temperature(TMY3 99%) 29 F Summer design temperature(TMY3 99%) 95 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 41 F Summer temperature difference 20 F Total heating load calculation 8077 Btuh Total cooling load calculation 6713 Btuh Submitted heating capacity %of Calc Btuh Submitted cooling capacity %of Calc Btuh Total (Electric Heat Pump) 86.7 7000 Sensible (SHR= 0.75) 89.0 5250 Heat Pump+Auxiliary(0.0kW) 86.7 7000 Latent 214.4 1750 Total (Electric Heat Pump) 104.3 7000 WINTER CALCULATIONS Winter Heating Load (for 647 sqft) Load component Load Window total 81 sqft 1058 Btuh [ Cecinas l S% Wall total 554 sqft 2157 Btuh 1, taus(26.7%)i Door total 16 sqft 293 Btuh I W;ndo st131°Aid Ceiling total 647 sqft 845 Btuh Floor total See detail report 2451 Btuh Infiltration 18 cfm 833 Btuh Duct loss 440 Btuh i Cuas;6.4ti3 Subtotal 8077 Btuh Ventilation 0 cfm 0 Btuh I mril.(ts.3#;, TOTAL HEAT LOSS 8077 Btuh E:oors,,33.4%,I Coors 3.6% SUMMER CALCULATIONS Summer Cooling Load (for 647 sqft) Load component Load Window total 81 sqft 1180 Btuh Wall total 554 sqft 1323 Btuh I Ceilingsi 13.8%1 Door total 16 sqft 222 Btuh Ceiling total 647 sqft 927 Btuh Floor total 0 Btuh 1. Milisi15.7%i .^:indv7s717767.1 Infiltration 14 cfm 305 Btuh Internal gain 1230 Btuh Duct gain 509 Btuh Sens.Ventilation 0 cfm 0 Btuh ' Blower Load 200 Btuh — I Ooorsi3.3°%; Total sensible gain 5896 Btuh Y. Latentint(3.0%) Latent gain(ducts) 155 Btuh (' ) a '� 610iSCrt3 °4J ET)) gain(infiltration)cin infiltration 461 Btuh InfiLrll.a ; Latent gain(ventilation) 0 Btuh --..._ ( L Int.Baini18.3%1 Latent gain(internal/occupants/other) 200 Btuh CuMs( 911 9. °� Total latent gain 816 Btuh TOTAL HEAT GAIN 6713 Btuh EnergyGauge®System Sizing T i, • 8th Edition PREPARED BY: DATE: 8/21/18 EnergyGauge®/USRCZB v6.1 System Sizing Calculations - Summer Residential Load - Room by Room Component Details Jeff and Diane Day Project Title: 292 16th Street Day Addition Jacksonville, FL 32233 8/21/2018 Reference City: Jacksonville, FL Temperature Difference: 20.0F(TMY3 99%) Humidity difference:49gr. Component Loads for Room#1: Addition Type* Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Omt Len Hgt Gross Shaded Unshaded Shaded Unshaded 1 2 NFRC 0.19,0.32 No No S 8.7ft 2.Oft 40.0 40.0 0.0 10 12 415 Btuh 2 2 NFRC 0.19,0.32 No No E 1.2ft 2.0ft 24.0 0.0 24.0 10 25 592 Btuh Window Total 64(sqft) 1007 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 1 Frame-Wood-Adj 0.09 11.0/0.0 146.7 1.9 278 Btuh 2 Frame-Wood-Ext 0.09 11.0/0.0 106.7 2.8 294 Btuh 3 Frame-Wood-Ext 0.09 11.0/0.0 138.7 2.8 383 Btuh Wall Total _ 392(sqft) 956 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 1 Vented Attic/Light/Metal 0.032 30.0/0.0 372.0 1.43 533 Btuh Ceiling Total 372(sqft) 533 Btuh Floors Type R-Value Size HTM Load 1 Slab On Grade 0.0 372(ft-perimeter) 0.0 0 Btuh Floor Total 372.0(sqft) 0 Btuh Zone Envelope Subtotal: 2496 Btuh Infiltration Type Wholehouse ACH Volume(cuft)Wall Ratio CFM= Load Natural 0.16 2976 0.71 9.8 215 Btuh Internal Occupants Btuh/occupant Appliance Load gain 1 X 230 + 1000 1230 Btuh Sensible Envelope Load: 3941 Btuh Duct load Average sealed,Supply(R8.0-Attic),Retum(R8.0-Attic) _ (DGM of 0.098) 387 Btuh Sensible Zone Load 4328 Btuh Component Loads for Room#2: Remodeled Space Type* Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Omt Len Hgt Gross Shaded Unshaded Shaded Unshaded 3 2 NFRC 0.19,0.32 No No N 8.0ft 2.Oft 16.7 0.0 16.7 10 10 173 Btuh Window Total 17(sqft) 173 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 4 Frame-Wood-Ext 0.09 11.0/0.0 69.1 2.8 191 Btuh 5 Frame-Wood-Adj 0.09 11.0/0.0 93.3 1.9 177 Btuh Wall Total 162(sqft) 368 Btuh Doors Type Area(sqft) HTM Load 1 Insulated-Exterior 15.6 14.3 222 Btuh Door Total 16 (sqft) 222 Btuh EnergyGauge®/USRCZB v6.1 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) Jeff and Diane Day Project Title: Climate:FL_JACKSONVILLE_INTL_ARPT 292 16th Street Day Addition Jacksonville, FL 32233 8/21/2018 Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 2 Vented Attic/Light/Metal 0.032 30.0/0.0 275.0 1.43 394 Btuh Ceiling Total 275(sqft) 394 Btuh_ Floors Type R-Value Size HTM Load 2 Slab On Grade 0.0 275(ft-perimeter) 0.0 0 Btuh Floor Total 275.0(sqft) 0 Btuh Zone Envelope Subtotal: 1157 Btuh Infiltration Type Wholehouse ACH Volume(cuft)Wall Ratio CFM= Load Natural 0.16 2200 0.29 4.1 89 Btuh Internal Occupants Btuh/occupant Appliance Load gain _ 0 X 230 + 0 0 Btuh Sensible Envelope Load: 1246 Btuh Duct load Average sealed,Supply(R8.0-Attic),Retum(R8.0-Attic) (DGM of 0.098) 122 Btuh Sensible Zone Load 1368 Btuh EnergyGauge®I USRCZB v6.1 Page 2 Manual J Summer Calculations Residential Load - Component Details (continued) Jeff and Diane Day Project Title: Climate:FL_JACKSONVILLE_INTL_ARPT 292 16th Street Day Addition Jacksonville, FL 32233 8/21/2018 WHOLE HOUSE TOTALS Sensible Envelope Load All Zones 5187 Btuh Sensible Duct Load 509 Btuh Total Sensible Zone Loads 5696 Btuh Sensible ventilation 0 Btuh Blower 200 Btuh Whole House Total sensible gain 5896 Btuh Totals for Cooling Latent infiltration gain (for 49 gr. humidity difference) 461 Btuh Latent ventilation gain 0 Btuh Latent duct gain 155 Btuh Latent occupant gain (1.0 people @ 200 Btuh per person) 200 Btuh Latent other gain 0 Btuh Latent total gain 816 Btuh TOTAL GAIN 6713 Btuh EQUIPMENT 1. Central Unit Existing# 7000 Btuh *Key: Window types(Panes-Number and type of panes of glass) (SHGC-Shading coefficient of glass as SHGC numerical value) (U-Window U-Factor) (InSh-Interior shading device:none(No),Blinds(B),Draperies(D)or Roller Shades(R)) letinfig - For Blinds:Assume medium color,half closed For Draperies:Assume um weave,half closed For Roller shades:Assume translucent half closed (IS-Insect screen:none(N),Full(F)or Half('h)) .,..r., (Ornt-compass orientation) Version 8 EnergyGauge®/USRCZB v6.1 Page 3 System Sizing Calculations - Winter Residential Load - Whole House Component Details Jeff and Diane Day Project Title: 292 16th Street Day Addition Jacksonville, FL 32233 Building Type: User 8/21/2018 Reference City: Jacksonville, FL (Defaults) Winter Temperature Difference:41.0 F (TMY3 99%) Component Loads for Whole House Window Panes/Type Frame U Orientation Area(sqft) X HTM= Load 1 2, NFRC 0.19 Vinyl 0.32 S 40.0 13.1 525 Btuh 2 2, NFRC 0.19 Vinyl 0.32 E 24.0 13.1 315 Btuh 3 2, NFRC 0.19 Vinyl 0.32 N 16.7 13.1 219 Btuh Window Total 80.7(sqft) 1058 Btuh Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 1 Frame-Wood -Adj (0.095) 11.0/0.0 147 3.89 570 Btuh 2 Frame-Wood - Ext (0.095) 11.0/0.0 107 3.89 415 Btuh 3 Frame-Wood - Ext (0.095) 11.0/0.0 139 3.89 539 Btuh 4 Frame-Wood - Ext (0.095) 11.0/0.0 69 3.89 269 Btuh 5 Frame-Wood -Adj (0.095) 11.0/0.0 93 3.89 363 Btuh Wall Total 554(sqft) 2157 Btuh Doors Type Storm Ueff. Area X HTM= Load 1 Insulated - Exterior, n (0.460) 16 18.9 293 Btuh Door Total 16(sqft) 293Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 1 Vented Attic/L/Metal (0.032) 30.0/0.0 372 1.3 486 Btuh 2 Vented Attic/L/Metal (0.032) 30.0/0.0 275 1.3 359 Btuh Ceiling Total 647(sqft) 845Btuh Floors Type Ueff. R-Value Size X HTM= Load 1 Slab On Grade (1.180) 0.0 38.0 ft(perim.) 48.4 1838 Btuh 2 Slab On Grade (1.180) 0.0 12.7 ft(perim.) 48.4 613 Btuh Floor Total 647 sqft 2451 Btuh Envelope Subtotal: 6805 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.21 5176 1.00 18.5 833 Btuh Duct load Average sealed, R8.0, Supply(Att), Return(Att) (DLM of 0.058) 440 Btuh All Zones Sensible Subtotal All Zones 8077 Btuh EnergyGauge®/USRCZB v6.1 Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) Jeff and Diane Day Project Title: 292 16th Street Day Addition Jacksonville, FL 32233 Building Type: User 8/21/2018 i'VHOLE HOUSE TOTALS Subtotal Sensible Heat Loss 8077 Btuh Totals for Heating Ventilation Sensible Heat Loss 0 Btuh Total Heat Loss 8077 Btuh EQUIPMENT 1. Electric Heat Pump Existing# 7000 Btuh Key:Window types-NFRC(Requires U-Factor and Shading coefficient(SHGC)of glass as numerical values) or-Glass as'Clear or'Tint'(Uses U-Factor and SHGC defaults) U-(Window U-Factor) # :� HTM-(Manual]Heat Transfer Multiplier) ' 14 Version 8 EnergyGauge®/USRCZB v6.1 Page 2 Air Conditioning Contractors of America, Manual D, Third Edition Friction Rate Worksheet Step 1) Manufacturer's Blower Data External static pressure (ESP) 0.6 IWC CFM from manufacturers tables Heating Cooling 210 210 Fan Speed Med Med Step 2) Component Pressure Losses (CPL) Direct expansion refrigerant coil 0.15 Electric resistance heating coil 0.01 Hot water coil heat exchanger Low efficiency filter High or mid-efficiency filter 0.15 Electronic filter Humidfier Supply outlet 0.03 Return grille 0.03 Balancing damper t 0.02 UV lights or other device Total component losses (CPL) 0.39 IWC Step 3)Available Static Pressure (ASP) 0.21 IWC Step 4)Total Effective Length (TEL) 435 Feet Step 5) Friction Rate Design Value (FR) 0.05 IWC/100 Air Conditioning Contractors of America, Manual D,Third Edition Duct Sizing Worksheet 1 Supply-side Runouts Equivilent Rect.Duct Equivilent ID Room ID H-Btuh C-Btuh Htg Cfm Clg Cfm Dsn Cfm Round Size Velocity Final Size Height Width Flex SR-1 Owner's Suite 4814 4001 125 125 125 8 359 8 6 8 8 SR-2 Master Bath 2847 2366 74 74 74 6 377 6 6 5 7 SR-3 Bath 237 197 6 6 6 4 71 4 4 3 4 SR-4 Master Toilet 178 148 5 5 5 4 53 4 4 3 4 SR-5 SR-6 SR-7 SR-8 SR-9 SR-10 SR-11 SR-12 SR-13 SR-14 SR-15 SR-16 SR-17 SR-18 SR-19 SR-20 8077 6713 210 210 210 Supply-side Trunks Equivilent Rect.Duct Equivilent ID Associated Supply Runs Dsn Cfm Round Size Velocity Final Size Height Width Flex 1 2 3 4 5 6 7 6 9 10 11 12 13 14 15 16 17 18 19 20 ST-1 D❑JOOOCC❑❑DOJC❑CGCO_ ST-2 ❑�UU (� [~fJ UJL7Cr GOA ST-3 ❑❑❑❑ ❑CC❑❑JO❑ ❑DCC❑O,_ ST-4 JLID UDOLL UUJCI _1 Lill LiLU`` ST-5 ]ULUJULLUUJOJLULLt_O`` ST-6 7nfln7nr-r,nnnDT11-7r,r-n❑T, ST-7 E -8 Dl �DD D -1-E CD e ` Return-side Runouts EquIvilent Rect.Duct Equivilent ID -17.1717117.171M Associated Supply Runs Dsn Cfm Round Size Velocity Final Size Hei ht Width Flex RR-1 ETfl i 7.1 1.'CL"1..1;7I_..l-1L i _ RR-2 iJU_IUJULLUU:JOJULiLLIELJ . RR-3 JCIJUJ❑LL❑UJO LJLLLJ RR-4 JCI IU ..1 Li L'IJUJO LL]L: L1L1 RR-6 : LiLiD DCC❑❑U❑ CJCDED7 RR-6 Dnr nL-Icr Lu u D,.lLr,cL-1--- RR-7 D❑ ❑DDf❑❑❑❑❑JL,'DCE1C❑C! RR-8 JUJUJLLLUUJUJLJLLLU_ RR-9 `i[J ❑J`JLLUU:7❑DL'=JfCCUL RR 10;_1[1'TCl:._I. r::7177:11.1;_l(....1) l-1 s J t�71 ?_ :.I Return-side Trunks Equivllent Rect.Duct Equivilent ID Associated Suppl Runs Dsn Cfm Round Size Velocity Final Size Height Width Flex RT-1 11D LT'JLL`L :1-1] LjL Jfs RT-2 ❑:Dn2.L❑OD❑ CSL C ❑` RT 3 "fn'I fl t:i l- ;❑rrn -1 [771[777711-- RT-4 . !f f' 11--RTS f1111"i1'_l"1 :L_]('Ll... '.l 11 _!1 : [111— Air Conditioning Contractors of America, Manual D, Third Edirtion Effective Length Worksheet Element Supply Run ID Number Straight Run Length MEEEN RIZBE Trunk Length 35 Trunk Length Trunk Length Runout Length 10 Fittings Group Effective Group Effective Group Effective Group Effective Letters Length Letters Length Letters Length Letters Length Group 1 4 Group 2 4 Group 3 Group 4 4 4AD 60 Group 8 4 (4)8A 120 Group 9 4 Group 11 4 Group 12 4 Other Other Other Other Other Total Length 225 0 0 0 Design TEL 225 Element Return Run iD Number Straight Run ILEM1E Length MBE Length Trunk Length 20 - Trunk Length Trunk Length Runout Length 10 Fittings Group Effective Group Effective Group Effective Group Effective Letters Length Letters Length Letters LengthLetters Length Group 5 4 Group 6 4 Group 7 4 4AD .1 Group 8 4 (4)8A 120 Group 10 4 Group 11 4 Group 12 4 Other Other -- --- - Other Other Total Length 210 0 0 0 Design TEL 210 1 ST FLOOR BATH 6 CFM O 4„ � GARAGE MASTER BATH 5 CFM 4"0�MASTER 74 CFM 0 TOILET I WIC MASTER SUITE 125 CFM O 8-� 0 CONNECT BRANCH DUCT TO EXISTING TRUCK DUCT JOB: DAY ADDITION PERFORMED BY: SCALE: 3/16"= 1'0" DUCTWORK HAS BEEN SIZED IN ADDRESS: 292 16th Street KALOS ENGINEERING LLC. ACCORDANCE WITH ACCA MANUAL JACKSONVILLE FL 2734 RIVER OAK DR. D — SEE SUPPORT CALCULATIONS ORANGE PARK FL, 32073 FOR DUCT SIZES. PROVIDE RELEASE DATE: 8-21-18 904 270 9734 REGISTERS FOR ALL GRILLES. CUSTOMERSUPPORTOGETENERGYFORMS.COM PROVIDE TRANSFER FOR RETURN AIR WHFRF RFOIIIRFO BY FRC.