Loading...
1883 ATLANTIC BEACH POOL18-0033SWIMMING POOL PERMIT PERMIT NUMBER CITY OF ATLANTIC BEACH POOL18-0033 8005EMINOLEROAD ISSUED: 10/9/2018 ATLANTIC BEACH. FL 32233 EXPIRES:4/7/2019 NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 1883 ATLANTIC BEACH DR SWIMMING POOL SWIMMING In ground Pool $40452.00 POOL RESIDENTIAL 169505 1570 ATLANTIC BEACH COUNTRY CLUB UNIT 02 ADDRESS: CITY: STATE: ZIP: SURFSIDE POOLS 313 BEACH BLVD Jacksonville Beach FL 32250 ADDRESS: CITY: STATE: ZIP: David Lamolinara 1883 Atlantic Beach Atlantic Beach FL 32233 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Issued Date: 10/9/2018 1 of 2 SWIMMING POOL PERMIT PERMIT NUMBER CITY OF ATLANTIC BEACH POOL18-0033 ` 8 ISSUED: 10/9/2018 00 SEMINOLE ROAD EXPIRES: 4/7/2019 ATLANTIC BEACH. FL 32233 DESCRIPTION'; FEES NICCOl1ITr �';kna H�. ��AIO AIwOiNT BUILDING PERMIT 455-0000-322-1000 0 $255.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $127.50 PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $5.74 STATE DCA SURCHARGE 455-0000-208-0600 0 $3.83 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $50.00 TOTAL: $542.07 Issued Date: 10/9/2018 2 of 2 �S�:Lvff� City of Atlantic Beach 1. Building Department r ` 800 Seminole Road �r Atlantic Beach, Florida 32233-5445 F Y Phone (904) 247-5826 • Fax (904) 247-5845 E-mail: buildin de t coab.us '�JR �9- P @ City web -site: http://www.coab.us APPLICATION NUMBER (To be assigned by the Building Department.) 'Poo L-11 - 03 Date routed: O Z O APPLICATION REVIEW AND TRACKING FORM Property Address: 1983 A- HSL' a -H - Bea-cA( Applicant: SLc..r'fS1 e ?0 Project: 103nwlaC4o0 Department review required Yes No u' (Plannina & Zonin Tree Administrator Public Wor Public Utilities Public Safety Fire Services ;Review fee $..., Dept Signature Other Agency Review or Permit Required Review or Receipt Dateof Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPI IrIATION STATUS Reviewing Department First Review: Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: poc' BUILDIN PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Review: ❑Approved as revised. PDenieaU ❑Not applicable PUBLIC WORKS Comments:, PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: Third Review: ❑Approved as revised. ❑Denied. [—]Not applicable FIRE SERVICES Comments: Reviewed by: Date: Revised 05119/2017 Building Permit Application City of Atlantic Beach 800 Seminole Road, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Fax: (9041247-5845 p Permit Number: 1 06 W 063,5 LaT 55 RE# 1(09S05 -JL5 19 Job Address: 1883 ATLANTi C ri Legal Description MT-1-AN11 C.vo Valuation of Work (Replacement Cost) $ 4o, 451. O° Heated/Cooled SF Non- Heated/Cooled • Class of Work (Circle one): ew Addition Alteration Repair Move Demo 41003 Window/Door • Use of existing/proposed structure(s) (Circle one): Commercial esidentia • If an existing structure, is a fire sprinkler system installed? (Circle one): Yes No N/ • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: IN-Ca0.o"r1D Co tJ CRETE S W 1 M M i t4 G 900L. �■ x 1.5� 10,250 GP►LL0N5 Florida Product Approval # for multiple products use product approval form Property Owner Information V1D E L Ati:o�.i N A R� Address: 1.83 ATL.A rJTi G �E4 r.�'1 Name: DAF�LV D State L. Zip 7>22.33 Phone city ATt_Ahmic gEAc.N �— E -Mail i ..r wI C R Owner or Agent (If Agent, Power of Attorney or Agency Letter Required) Contractor Information ' 60%4 Name of Com any: CCoTfAM IfdC db. SuRfsil)E Qualifying Agent: �HPI C� SG°T7 City 'TAr �So irLLl _ ate F L Zip 32'L5o Address 315 5E CH Bt_yD rr gµ0w,4 90`i-2�-iso'3�ols Job Site/Contact Number �""' `' Office Phone g0`41-�2.�1(0-up(Ay t� State Certification/Registration # CPC044080 E-Mail�tr 4 S�..r �S i c�� ■� het Architect Name & Phone # Engineer's Name & Phone #-Lb 19 _ Workers Compensation R' �� Exempt sure Lease Employees / Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TOC�o BTffgnatureof G, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RERDTICE OF COMMENCEMENT. J°l r Agent including Contractor) (Signature of Contractor) Signed and sworn to (or affirmed) before me this day of Signed a sworn to (or affirmed) before me this day of �uL.j Z.b18 , by (>s;,:a LAW10LinIARA Nva ST ZOI$ by So c �((Siignar,ota ) Wellman (Sign re ofNotary)W W eNrrtan ,Dww" NOTARY PUBLIC NOTARY PUBLIC STATE OF FLORIDA STATE OF FLORIDA Comrr# FF937185 Personally Known OR Conxtt# FF937185 [ j Personally Known OR 11/18/2019 Expires 11/18/2019 QQ Produced Identification Expires [ j Produced Identification Type of Identification: F L_ Q L Type of Identification: SurfSide Pools & Spas 313 Beach Boulevard ro V5%e Jacksonville Beach, FL. 32250 OFFICE COPY •���"'� CPC 044080 Pools • Spas • Service �. Title Page/Index of Drawings Prepared By Marcus Medlock For Surfside Pools August 17, 2018 904-246-2666 Ext. 117 marcus@surfsidepools.net Property Owner of In ground Pool Project: David & Jennifer Lamoninara 1883 Atlantic Beach Blvd. Atlantic Beach, FL. 32233 Index of Drawings Pg 1: / • Site Permit Plan (Pool Layout and Details) Y Conforms to Codes: Florida Building Code 6th Edition (2017) Residential Conforms to Chapter 42; 2014 National Electrical Code; Atlantic Beach Unified Land Development Code Occupancy Class: Group R-3 Pg 2 • Survey w/ pool, pool equipment, Barriers: Fence & Alarms✓ Pg 3 • Survey w/ no alterations Pg 4-7: • Construction Drawings .MN. • Simplified Total Dynamic Head Calculation • ANSI/APSP/ICC 15 Worksheet Pg 10-20 • Product Specification Sheets Impervious Calculations: Total Lot: 10,672 sq. ft. House: Drive/walk: Pool/Coping/Deck: Total: ISR: 35.27% 2,115 sq. ft. 1,065 sq. ft. 868 sq. ft. 3,765 sq. ft. �S CITY OF ATLANTIC BEACH ,+ 800 Seminole Road s Atlantic Beach, Florida 32233 REVISION REQUEST /CORRECTIONS TO PLAN REVIEW COMMENTS Date I /I0A01Z Revision to Issued Permit Corrections to Comments_ Permit # Project Addresst> -3 / -f Contractor / Contact Name 5'^-`� S'tke S� as Phone O - 21+� ALtoL Description of Proposed Revision / Corrections: 11) e ck- 5 i 2e- ri e-kttee-9- Email aGLr ��S�r�s� CC.e-b015 VITT Permit Fee Due $ ►iMV�QCV'iLt, ccs-, CLt tCAJioJA5 _Udd- e� Additional Increasemai-�� in Building Value $ Additional S.F. By signing below, I jal l ' �.J I oc- L-- affirm the Revision is inclusive of the proposed changes. (printed name) Signature of Contractor/Agent (Contractor must sign if increase in valuation) Date Approved Revision/Plan Review Comments Department Review Required: Tree 'nistrator Publi Public Utilities Public Safety Fire Services (Office Use Only) Denied Ped sty Not Applicable to Department Reviewed By Date &fibG aICS BUILDING INSPECTION DIVISION Whae i' ori& Begins. REVISING ACTIVE PERMIT FORM DATE: 9/10/2018 JOB NAME: LAMOLINARA ADDRESS: 1883 ATLANTIC BEACH BLVD PERMIT NO: POOL 18-003 (BUILDING PERMIT) CONTRACTOR: SURFSIDE POOLS & SPAS PHONE NO: 904-246-2666 FAX NO: ARCHTECT /ENGINEER PHONE NO: FAX NO: BUILDING PLANS EXAMINER: REVISIONS FOR: COMMENTS PLEASE INDICATE BUILDING YES NO YES NO LANDSCAPE YES NO YES NO PLUMBING YES NO YES NO FIRE MARSHAL YES NO YES NO MECHANICAL YES NO YES NO ELECTRICAL YES NO YES NO MARCUS MEDLOCK SUBMITTED BY: PLANNING and DEVELOPMENT DEPARTMENT 214 N. Hogan Street, Room 273 Jacksonville, FL 32202 Phone: 904.630.1100 j Fax: 904.255.8552 ( www.coj.net City of Atlantic Beach Building Department r `1 800 Seminole Road r� Atlantic Beach, Florida 32233-5445 Phone (904) 247-5826 •Fax (904) 247-5845 o jr E-mail: building-dept@coab.us City web -site: http://www.coab.us APPLICATION NUMBER (To be assigned by the Building DepartmenOvk--t.) Date routed: O Z APPLICATION REVIEW AND TRACKING FORM Property Address: IS83 A-Ha-� �G Be&CA, Applicant: &A- r4 s j< Project: ' 5 Od Department review required I Yes INo Tree Administrator Public Wo -r15> Public Utilities Public Safety Fire Services Review fee $ Dept Signature ,.-*00 ...._ . Other Agency Review or Permit Required Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: Review or Receipt Date of Permit Verified By .-.. ..+e-rr%kl 011"A711C Reviewing Department First Review: []App roved. Denied. ❑Not applicable (Circle one.) Comments: Q��� BUILDING jl 7 S PLANNING & ZONING/��/� Date: Reviewed by: TREE ADMIN. Second Review: ❑Approved as revised. �enied. []Not applicable PUBLIC WORKS Comments: A� PUBLIC UTILITIES Reviewed by :."-� Date: PUBLIC SAFETY FIRE SERVICES Third Review: ❑App roved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05119/2017 Building Permit Application City of Atlantic Beach 800 Seminole Road, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Fax: (904) 247-5845 Job Address: IM ATL•ANTi c. &Ac.H ?)LV D. Permit Number: f bOi L► f ` 0633 Legal Description ATL. WTiC SEAC%4 CO%ANTiVY Lula UNi: Z UT 55 RE# 1(09505-1570 Valuation of Work (Replacement Cost) $ 40, 452 0o Heated/Cooled SF Non- Heated/Cooled • Class of Work (Circle one): ew Addition Alteration Repair Move Demo 0o Window/Door • Use of existing/proposed structure(s) (Circle one): Commercial esidentia • If an existing structure, is a fire sprinkler system installed? (Circle one): Yes No N/ • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: TN- CaRo"r o cord cRETf SvJ i M M i IJ G Poo L. 30 x 15� J.0,150 GAL.LoNS Florida Product Approval #. Proaerty Owner Information for multiple products use product approval form Name: DAvID E. L AMo%-', W A RA Address: I-88'5 ATLA nITi C_ BFAC-H f City NrL it 6EAc,%4 State FL Zip 37-2.33 Phone 904-23-1-1(015 E -Mail Owner or Agent (If Agent, Power of Attorney or Agency Letter Required) nysiblEIR Contractor Information 1?00%-5 Name of company: Sr OrFAM '10c.• db. SuRFSi AE Qualifying Agent: �H�l C• SC OTT Address 31'5 BES H S L.Q D. City ?AcMGSa LJvi1\E ate F L Zip S L50 Office Phone g04-T4(o-7.l.o(o(o Job Site/Contact Number ,MELooi iii P F-ov w 904-2.46- 3(OIS State Certification/Registration # CPC,0446F00 E -Mail Aar'.L S�wri'S i c�e.Doo IS. het Architect Name & Phone # Engineer's Name & Phone # Workers Compensation A mem SURE OLi-01- 2019 _ Exempt sure Lease Employees / Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBT N FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORD G UR NOTICE OF COMMENCEMENT. (S gnature of Owner or Agent including Contractor)(Signature of Contractor) 1i Signed and sworn to (or affirmed) before me this -1day of Signed a sworn to (or affirmed) before me this day of �VL_�( 7.0%6 , byl)AViO Lpih&L ,'WAR@_ uca ST ZC1Ib,by:roI4N Scorr1U e (Signa re ofOta ) Wellman(Sign re of Notary) NOTARY PUBLIC NOTARY PUBLIC STATE OF FLORIDA STATE OF FLORIDA [ ]Personally Known OROlEores Comm* FF937185�Q Personally Known OR� Comm# FF937185 Qq Produced Identification 11!18/2019 [) produced Identification 1 Facpires 11/18/2019 Type of Identification: F L_ Q L- • Type of Identification: TREE & VEGETATION AFFIDAVIT City of Atlantic Beach Department of Community Development Planning & Zoning Division 800 Seminole Road Atlantic Beach, FL 32233 PERMIT # (P) 904 247-5800 (F) 904 247-5845 SECTION I - APPLICANT INFORMATION NAME OF APPLICANT DAv 1 p E. ot- i rA ARB, NAME OF COMPANY SIIRFSIDF POOLS JZ Owner(s) r Legal Authorized Agent* ADDRESS OF COMPANY 313 BEACH BLVD. JACKSONVILLE BEACH, FL 32250 PHONE Cloy- 246-2666 CELL CONTRACTOR CERTIFICATION NUMBER CPC044080 ATLBCH BUSINESS TAX RECEIPT NUMBER 9A, -y EMAIL y@surfsidepools.net SECTION II - SITE INFORMATION Q 0� 1„$USTREET ADDRESS OF PROPERTY ^7 SANT; c-PJE CH R►.1E If an address has not been assigned to this property, contact the AB Building Department at (904) 247-5826 to request an address. LEGAL DESCRIPTION D1-132 08 -IS -2.9E -25 LOT 5 5 BLOCK ATI.-ANTic- ?3>EAc t1 SUBDIVISION C,ou NTR`( C.W 6 REAL ESTATE NUMBERf. vP1505 - '15-70 LOT OR PARCEL SIZE: SQ FT AC r RESIDENTIAL COMMERCIAL OTHER (SPECIFY) '` .,, L € 1 affirm that 1 have reviewed the provisions of Chapter 23, "Protection of Trees and Native Vegetation" of the Municipal Code of Ordinances for the City of Atlantic Beach, FL and/or I have participated in a pre -application meeting with the Administrator of those regulations. S sequentl I affirm that no regulated trees and no regulated vegetation will be damaged, destroyed and/or removed from the abo s�C'be or adjacent properties in conjunction with this project. y. SIGNAT RE OF OWNER SIGNATURE OF OWNER Signed and sworn before me on this Z,�i day of �N Lam( 2018 , by �AyiO E LAMOL.i WASA Identification verified: Oath sworn: �K Yes REV -TVA -00.12 r- No Notary Signatu_ My Commission expires: (1' 1 )/19 State of �: L - County of D"14 A L Devany WeNffm NOTARY PUBLIC STATE OF FLORIDA Comm* FF937185 t Expires 11/18/2019 OFFICE COPY ANSI/APSP/ICC 15 Worksheet Swimming Pool Energy Efficiency Compliance Information NOTE: These Requirements Apply ONLY to the Filtration Pump Project Name David & Jennifer Lamolinara Project Address 1883 Atlantic Beach Blvd. Atlantic Beach Pools • Spas *Service Maximum Filtration flow rate calculations Pool water volume 10250 _ 360 = 29 qpm = filtration flow rate Is there an Auxiliary load on the filtration pump? Fx-] Yes No If so, what is the auxiliary flow rate 24 gpm Maximum Flow Rate 36 gpm (maximum auxiliary pool loads or the filtration flow rate, whichever is greater). The pool filtration flow rate shall not be greater than the rate needed to turn over the pool water volume in 6 hours or 36 gpm, whichever is greater. This means that for pools of less than 13000 gallons, the pump shall be sized to have a flow rate of 36 gpm or less Filter Factors: [K(Cartridge .375) F-11D.E. 2) F� (Sand 20) 36 (Flow rate) - 0.375 (filter factor) = 96 (minimum filter size) Filter Make/Size Jandv CS150 Cartridge Backwash valve? YesX No Pump Selection from APSP database on Curve A ❑X (less than 17000 gallons) or C (greater than 17000) gallons) (check one) Pump Model Jandy FloPro VS -FHP 1 hp Flow Rate (low speed) 28.9 gpm @ 1725 rpm Flow Rate (high speed) 59 gpm @ 3450 rpm (not required if no auxiliary load) Pump Controls Standard time clock 1:1 2 speed time clock 1-1 Other QJANDY Variable Speed Controller Heater Model None Gas Heater efficiency rating % (No Pilot Light) Heat Pump Model 0 Heat Pump efficiency C.O.P.(High Temp) (Low Temp) Suction side filtration branch piping size = 1 1/2 in. per ANSI -15 @ 6 fps Suction side filtration trunk line piping size 1 1/2 in. per ANSIA 5 @ 6 fps Return side filtration branch piping size = 1 1/2 in. per ANSI -15 @ 8 fps Return side filtration trunk line piping size = 1 1/2 in. per ANSI -15 @ 8 fps Notes: suction piping in front of pump inlet must be 4 pipe diameters in length. Must have 18" of straight pipe after the filter for solar. Vacuum line, if installed shall be sized to flow at 8 fps per ANSI -5 and shall be covered per ANSI -7. ng, self -latching cover I affirm that the information above is true and correct -� � f -- ---- re cJan8 > Pro Series by ZODIAC® Technical Specifications CS Series Filters OFFICE COPS' Part No. Description Size Specifications and Dimensions, CS Series Filters CS Filter Head Loss Curves 6 6 Design Head Loss (ft head) 4 Design Pressure 2 Drop (psi) 01 I I I I 0 0 30 60 90 120 CS150 Flow Rate (gpm) - CS200 CS250 m CS100 www.ZodiacPoolSystems.com Model No. CS100 Filter Area 1100ft, 150 1112 200 ft' 250 ft2 Design Flow Rate 1 gpm/ft2 .85 gpm/ft2 .625 gpm/ft2 .5 gpm/ft2 Maximum Flow 100 gpm 125 gpm 125 gpm 125 gpm Six (6) Hour 36,000 45,000 gal- 45,000 45,000 gal - Capacity gallons Ions gallons Ions Eight (8) Hour 48,000 60,000 gal- 60,000 60,000 gal - Capacity gallons Ions gallons Ions Normal Start Up 6-15 psi 6-15 psi 6-15 psi 6-15 psi Pressure Max. Working 50 psi 50 psi 50 psi 50 psi Pressure Cartridges 1 1 1 1 Required Shipping Weight 28 lbs. 28 lbs. 34 lbs. 36 lbs. Height ('A') 3231V 323/e 42'/z" 42'/i 02011 Zodiac Pool Systems, Inc. SA6259 0611 ZODIAC® is a registered trademark of Zodiac International, S.A.S.U., used under license. CS150 CS200 CS250 02011 Zodiac Pool Systems, Inc. SA6259 0611 ZODIAC® is a registered trademark of Zodiac International, S.A.S.U., used under license. Maximum Efficiency. Up to 70% Quieter' Ultra -Compact Design. . NO - •� 2 r R r , , } 3� Save up to 90% on energy costs with the VS RoPro 1.65 HP Variable -Speed Pump2 VS FloPro is designed with an innovative adjustable base, allowing for simple installation on new construction, or quick and easy replacement of existing pumps. Well suited for applications with 1.5" or 2" plumbing, the VS FloPro is designed to be operated at energy-saving lower speeds for maximum efficiency. >> Ultra high -efficiency motor Features a totally enclosed fan -cooled (TEFC) permanent magnet brushless DC motor for cooler operation and extended motor life. >> On -board digital controller included' Two timed speeds/8 speeds total. 180° rotatable and remote mountable for easy installation. Reliable battery backup ensures time and settings are stored during power outages. » Compact High-performance pump in an ultra -compact body. Fits easily in small equipment areas. » Additional features • Adjustable base included' • 2" unions and 2" internal threads • Ergonomic easy -transport handle • High profile easy -grip handles with large capacity basket » Complies with Appliance Efficiency Standards (CEC Title 20 & ANSI®/APSP-15) and qualifies for power rebates, where offered. Zodiac Pool Systems, Inc. 2620 Commerce Way, Vista, CA 92081 1.800.822.7933 1 www.ZodiacPooLSystems.com i.................................................................................................... Zodiac Pool Systems Canada, Inc. 2115 South Service Road West, Unit q3, Oakville, ON L6L 5W2 1.888.647.4004 1 www.ZodiacPoolSystems.ca BAS; f ONIFIGURll x; VSFHP270JEP Y Hayward•SuperPump! No base Pentair- SuperFlo• required VSFHP270AUT Y m Sta-Rite•SuperMax• ` Recomm•nd•d Carton VSFHP270JEP Y Hayward Super ll" Small base Length VSFHP165JEP 1.65 Jandy Pro Series Plus HP *V* mt•��w VSFHP270AUT N VSFHP165AUT' 1.65 & Max HP Small base VSFHP270JEP Y PentairWhisperFlo® ntre�lu VSFHP165AUT w/spacers Sta-Rite•Dyna-Gla= VSFHP270AUT N Small base- VSFHP270JEP y Sta-Rite Max -E -Pro? Sta-Rite Dura -Glass tT!r NMI large base` Sta-Rite Dura-Glas II, VSFHP270AUT N I Sta-Rite Max -E -Glass Total t a I Horse- F t i j -j Recomm•nd•d Carton Overall Model No. power Voltage Max Watts Pipe Size-' Weight Length VSFHP165JEP 1.65 230VAC 1,600 W W -Th" 46 Itis 251A" VSFHP165AUT' 1.65 230VAC 1,600 W 11h -21h" 461bs 251/4' 1734"M1 VSFHP165AUT H 0 VSFHP165 PERFORMANCE CURVES no 1 t a I F t i j -j wm to 1734"M1 0 1• m N .0 aY M ry M w m .,. ... ... FLOW GPM 1 Up to 70% quieter than traditional single -speed pumps. ' Actual savings dependent on pump horsepower, usage and energy costs. ' Does not include adjustable bases or user interface. Intended for use with AquaLink RS, AquaLink PDA, or AquaLink Z4 control systems. °Optional: Part # R0546400 =Always follow local building and safely codes for pipe sizing and guidelines. 02015 Zodiac Pool Systems, Inc. SL6210 Rev C 0415 NSF �[�j►� ZODIAC® is a registered trademark of Zodiac International, S.A.S.U., used under license. All other trademarks used herein are the property of their respective owners. OPERATION FOR ALL SKIMMERS Water is pulled through the skimmer by the suction of the pump. Water flow carries floating debris into the skimmer where it is collected in the skimmer basket. The floating weir creates a better water flow and increases efficiency. The water level of the pool should be kept at least 2" above the bottom of the mouth of the skimmer to ensure proper operation. To adjust the skimmer flow rotate the diverter plate on the float valve or in the skimmer until the desired flow is achieved. In the instance of multiple skimmers, rotate the diverter plate in each skimmer over the pump port to restrict and balance the flow from each skimmer. To vacuum the pool, remove the float valve and close the diverter plate over the main drain. Install the skimmer vacuum in the skimmer and connect to vacuum hose. OPERATION WITH DIVERTER PLATE For full flow, rotate diverter plate completely open. To adjust flow, rotate over the pump port until desired flow is achieved. To vacuum, either remove cover and basket. Screw the hose adapter into the pump port. Fill hose with water and insert over the hose adapter. OR insert the skimmer vacuum into skimmer on top of the basket. OPERATION WITH FLOAT VALVE If the water level drops below the mouth of the skimmer or if the basket is clogged and no water can flow through it, then the float valve will automatically close over the flow DIVERTE ports. This diverts all water flow to the pump from the main drain line. It prevents possible air lock. When the pump is shut off the float valve will float back to the top of the cavity, allowing normal operation to resume. TO SWEEP/BRUSH: Divert all suction to the main drain by holding the weir above normal operating level and allowing the float to snap shut. Or remove the float valve assembly, close the diverter plate, and replace. To reset the float valve assembly, turn off the pump for 10-15 seconds. The float valve will rise to the top of the skimmer cavity. TO VACUUM: Remove cover, basket and float valve assembly. Screw the hose adapter into the pump port, fill the hose with water, and insert over adapter. OR insert the skimmer vacuum into skimmer on top of the basket. OPERATION WITH FLOAT VALVE & EQUALIZER CHECK VALVE The Equalizer Check Valve Assembly screws into the main drain port and is used in tandem with the float valve assembly. If the water level drops or if flow is restricted, the float valve will snap down and the equalizer valve will open. This diverts all flow to the pump from the equalizer line and prevent airlock in the pump. When the pump is turned off, and the problem is corrected, the float valve will rise to the top of the skimmer cavity and the equalizer will close, allowing for normal operation to resume. D rccw y o-Rirx;� TO VACUUM: Remove cover and float valve from the selected skimmer. Place the vacuum plate over the basket. Fill the hose with water and insert over the hose adapter. Adjust the flow from the other skimmers until desired suction is achieved through the Ae vacuum. EQUALIZER , REPLACEMENT PARTS & ACCESSORIES GUIDE 40 TO MAIN DRAIN A WARNING RISK OF HAIR OR BODY ENTRAPMENT, DROWNING OR DISEMBOWELMENT. EQUALIZER FITTINGS CAN TRAP HAIR OR BODY PARTS CAUSING SEVERE t INJURY OR DEATH. PROVIDE MORE THAN ONE SUCTION SOURCE IN POOL SYSTEM AT ALL TIMES. FOR RESIDENTIAL USE: DO NOT USE EQUALIZER LINE. PLUG EQUALIZER LINE WITH PLUG USING NSF LISTED PVC CEMENT. -m- m 0t10DO0" ""a"" DDBDDOflOfl^^1 0000D0�" 15 .�JflDDD .JODDDDUD ann000aooa fir 1- COVER RETAINING SCREW 2- ADJUSTING COLLAR 3- COLLAR SCREW 4- COVER 5- FLOAT VALVE O-RING 6- DIVERTER PLATE 7- RETAINING SCREW 8- FLOAT VALVE ASSEMBLY O-RING 9- FLOAT VALVE ASSEMBLY 10- RETAINING SCREW 11- EQUALIZER GASKET 12- EQUALIZER CHECK VALVE 13- RETAINING SCREW 14- DIVERTER PLATE 15 -BASKET 16- FLOATING WEIR WATER BOND & ZINC ANODE SKIMMER GUIDE Water bond copper wire inside skimm( area and meets NEC section 680.2 C. OFFICE COPY WATER BOND COPPER WIRE Attach to equipotential bonding line with split bolt connector SPLIT BOLT CONNECTOR Inside skimmer zinc anode plate replacement P/N 25810-140-000. HOW TO REPLACE 1. Remove nut from thread stud on zinc anode. 2. Lift up the copper wire connector and remove zinc anode. 3. Replace zinc anode, reinstall connector, nut and tighten till snug. 0813sb CUSTOM MOLDED PRODUCTS 136 HERRING ROAD, NEWNAN, GA 30265 1 WWW.C-M-P.COM .an r,,,niq /`'-V -C INSTALLATION MANUAL ENGLISH I FRANCAISI ESPANOL Jandy Pro Series Underwater Pool and Spa White Lights FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist. In the event no such state or local requirement exists, the maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation will void the warranty. OFFICE COPS' PAGE 12 Jandy° Pro Series Underwater Pool and Spa White Lights I Installation Manual POOL WHITE LIGHT ASSEMBLY POOL WALL SPA WHITE LIGHT Power Niche Cord ASSEMBLY SPA WALL OUnscrew pilot screw and pull top of Ilght P*owe aUnscrew top of sl ht P assembly away from P g away from pool wall Bondi Spa P Bonding ca cable PILOT SCREW PILOT SCREW O2 Push upon light assembly Push up on bottom of POSI light assembly POSITIONING TAB TAB LOCATOR rigure i, rcemovtng the cool and Spa White Light Assembly for Lamp Replacement Reassemble the fixture as follows: a. If not already done, remove the gasket from the glass lens and install a new gasket, Jandy Pro Series Pool Light Gasket (P/N R0451101) and Jandy Pro Series Spa Light Gasket (P/N R0400501), on the lens. NOTE A new lens gasket must be used each time the light is reassembled. b. While holding the fixture upright, place the glass lens with the gasket on top of the fixture. Please note that the lens gasket is not symmetrical. Therefore, it must be installed correctly so that the lens can seal to the fixture housing. Place the gasket on the lens so that the thick molded side of the gasket will mate with the housing when the lens is installed. See Figure 11. Align arrow of the lens with pilot screw Position the lens and gasket on the fixture. Place the face ring and the top clamp over the lens and align the pilot screw with the small arrow mark on the face of the lens. Note that the small arrow mark on the face of the lens and the pilot screw of the face ring must be aligned with the arrow located on fixture label that reads, "Arrow on this label must line up with the pilot screw on the Face Ring". See Figure 8. d. While holding the aligned face ring assembly and fixture together, turn the assembly upside down and set it on the old gasket, using the old gasket as an assembly fixture. This will keep the lens and gasket assembly from being pushed out of the face ring while you secure it to the light fixture. e. Spread the bottom clamp over the electrical cord and slide it onto the back of fixture to the top clamp. See Figure 8. Align pilot screw with arrow located on fixture label Figure 8. Alignment of the Lens, Face Ring, Housing and Clamps for Pool White Lights THE HEAVY-DUTY STANDARD FOR MAXIMUM PERFORMANCE AquaPure® salt -water sanitizing systems use salt -water to deliver high-performance commercial -grade water sanitation with uncompromised performance, reliability, and hydraulic efficiency. » Robust Features • Automatic self-cleaning feature, which ensures consistent operation and extends the life of the cell. • Professional -grade, ruthenium coated titanium electrodes for long-term reliability. • Exclusive Tri -Sensor technology — reliable electronic water flow detection to ensure maximum performance. • Digital salinity read-out for accurate salt level indication • Flow, temperature, and status readings provide instant feedback on the current operation. » Easy Integration Seamless communication with AquaLink® Control systems, enabling easy monitoring of -salt levels and convenient, precise sanitizer output settings. When combined with PureLink'" power centers. AquaLink and AquaPure work together for the ultimate in pool sanitizing and remote operation convenience. • g Zodiac Pool Systems, Inc. 2620 Commerce Way, Vista, CA 92081 1.800.822.7933 1 www.ZodiacPoolSystems.com ................................................... Zodiac Pool Systems Canada, Inc. 2115 South Service Road West, Unit #3, Oakville, ON LbL 5W2 1.888.647.4004 1 www.ZodiacPoolSystems.ca OF F ICE COPYOUAPURE Water Purification System Aq-. . Zodiac* 2" x 21h" universal unions ""`— Digital salinity reading Ruthenium coated titanium electrodes for Flow, temperature, Long-term reliability and status readings Exclusive tri -sensor technology Commercial -grade construction Installs horizontally or vertically, in-line or as a 900 elbow 1 Aqu Llt re Meavy -duty, powder - coated steel enclosure Easily integrates with AquaLink• and iAquaLinko Automation Systems Removable Tri -Sensor and cordset assemblies for improved servicability SPECIFICATIONS 'N Model PLC700 Pt 01400 Pool Size` Up to 1200 Gallons Up to 40,000 Gallons Input 120 YAC, 50/60 Hz, 1.5 AMPS 120 VAC, 50/60 Hz, 2.5 AMPS 240 VAC, 50/60 Hz, 0.75 AMPS 240 VAC, 50/60 Hz,1.25 AMPS Out ut 22-30 VOC 0 3 AMP5 maximum 22-30 VDC 0 6 AMPS maximum Chlorine 0.6251b./24 Hr. 1283 m/24 Hr.) 1.251b./24 Hr. (567 m/24 Hr.) ecommende 20-120 GPM 2D-120 GPM Flow Rate 'Pool sizes are generalizations and may vary with environmental conditions. Pools with greater exposure to sunlight may require greater chlorine production capacity. CHARTHEAD LOSS Exceptional Hydraulic Efficiency 0.8 02012 Zodiac Pool Systems..enc. SL6605 Rev 10912 ZODIAC® sa registered trademark of Zod'uclnternernarwnal, SA.S.U., used under license. All other trademarks used herein.are the property of their raspective owners. in ut J d x U. d tv 0.00 20.0 40.0 6U.0 ov.0 Flow 10m) Lower head loss = more efficient Rollo Aviv Always plumb and Install,all augrdin� to ail Y tng cages that ap�rlYiyiour.' WARNING: The suction fitting and fasteners should be inspected for damage or tampering before each use of the facility. If the fitting/cover breaks, is damaged, or is missing, shut the system down immediately. Missing, broken, or cracked suction fittings must be replaced before using this facility. Use of the system with damaged, loose, or missing covers may result in serious injury or death. WARNING: Never exceed the maximum allowable flow rate stated on the suction fitting. In the event that one suction outlet is completely blocked, the remaining suction outlet(s) serving that system MUST have a flow rating capable of the full flow of the pump(s) for the specific suction system. CAUTION: Children should never be left unattended at any time in a swimming pool, spa, or bathtub. Be sure the temperature of the water never exceeds the manufacturer's recommendations. The maximum flow rating for this suction fitting with 1.5" plumbing is 118 GPM (Wall) and 140 GPM (Floor). The maximum flow rating for this suction fitting with 2" plumbing is 118 GPM (Wall) and 150 GPM (Floor). This suction fitting is 40 HEAD LOSS designed for installation on side wall or floor of hot tubs or pools in conjunc- (PAX 10' > tion with at least one other suction fitting per pump. DO NOT adapt suction fitting to any pipe size smaller than ASTM 1.5" SCH 40 PVC. Field built sumps 20 should be constructed per ANSI/APSP-16 Figure 2 (see below) found on page 5 of the Standard. Contact your local pool and spa professional for all w12terizing instructions and recommendations. Open area of cover is 14.57 0100 130 160 FLOW (GPM) 70 in . Results may vary- this data is provided for reference only. Tools Needed: Phillips Head Screwdriver INSTALLATION INSTRUCTIONS 1. Install sump provided or construct sump per ANSI/APSP-16 Figure 2 (see below) 2. If mounting frame is provided, secure it in concrete or plaster. 3. Use mounting screws to secure cover to frame or sump. 15Omm. Dmin. 0 D min. O min. tb O min. D (4 a -hold. "'nim O pp.. OafMI d1. Orn, sham ane nle.nuna td ab irr5rL-Jin"-su lmdit" �^• Dmm 7.5 O min. , a , Dmin. s Dmin Orrin is Orrin. D D INSTALLATION NOTES: 1. Mount suction outlets on the wall or floor. DO NOT locate suction outlets on seating areas or on backrests for seating areas. 2. Always use multiple suction outlets. DO NOT use with single drain applications. REPLACEMENT PARTS *Replace within 7 installed years or immediately upon evidence of degradation or damage. 'Y indicates color using digits 0-9, see catalog for color reference 25513-26X Sump 25513-250-010 Plug 25513-250-020 Cover 25539-7XX-011 Screw 61004-083-212 25513-6XX Sump 25513-110-010 Plug 25520-050-010 Cover 25539-7XX-011 O -Ring 26100-580-355 Screw 61004-083-212 25516-4XX Sump 25516-300-010 Extension 25516-000-020 Plug 25513-300-020 Cover 25539-7XX-011 Screw 61004-083-212 25539-5XX Frame 25539-000-020 Cover 25539-7XX-011 Screw 61004-083-212 25513-4XX Sump 25513-300-010 Plug 25513-300-020 Cover 25539-7XX-011 Screw 61004-083-212 25515-5XX Sump 25515-010-010 Plug 25520-040-010 Cover 25539-7XX-011 Ring 25532-70X-000 Gasket 25515-000-011 Reducer 25520-020-000 Screw 61051-052-028 25516-5XX Sump 25516-000-010 Extension 25516-000-020 Plug 25520-050-010 Cover 25539-7XX-011 O -Ring 26100-580-355 Screw 61004-083-212 25539-6XX Frame 25539-100-010 Cover 25539-7XX-011 Screw 61054-048-019 25513-5XX Sump 25513-010-010 Plug 25520-050-010 Cover 25539-7XX-011 O -Ring 26100-580-355 Screw 61004-083-212 25516-26X Sump 25516-250-010 Extension 25516-000-020 Plug 25513-250-020 Cover 25539-7XX-011 Screw 61004-083-212 25517-5XX 25518-000-010 25539-7XX-011 61050-048-025 25548-5XX 25532-70X-000 25539-7XX-011 61004-083-212 Use with single drain applications will void any and all warranties. 3. When using two or more suction fittings on a common suction line, suctions must be separated by a minimum of 3 ft or they must be located on two different planes (i.e. one on floor and one on the wall). 4. To reduce the risk of drowning from hair and body entrapment, install suction fittings with a marked flow rate in gallons per minute that exceeds the flow rate of your system by at least 25°x. Increasing size of the pump may increase flow rate of suction beyond rated safety limits causing entrapment or death. 5. CMP drain covers are only certified for use with CMP sumps and frames. Do not mismatch with parts from other manufacturers. AN D Hair or body parts blocking the spa or pool suctions may become trapped and held against the suction fitting. Keep hair and clothing a minimum of 12 inches from all suction fittings and drains at all times. Entrapment against the suction fittings can result in drowning or other severe injury. Never sit on or lean up against suction fittings. 0713sb CUSTOM MOLDED PRODUCTS 136 HERRING ROAD, NEWNAN, GA 30265 1 WWW.C-M-P.COM r�� CITY OF ATLANTIC BEACH 800 Seminole Road Atlantic Beach, Florida 32233 REVISION REQUEST / CORRECTIONS TO PLAN REVIEW COMMENTS pC)0L I S -�o33 Date o6 f Revision to Issued Permit_ Corrections to Comments_ Permit # ! V 00 3� Project Address ! L) l5 U rrl OW TCJIC- Contractor / Contact Name J O Y� c- a Phone 11.07 ;,q � ';-6 Description of Proposed Revision / Corrections: Dit Email c iJ r ` S u V'Z5 i1 o ( , e.iPo SKA V�GtrC�s�5ur-�5i�cpools, GO""'_ surVeLi �vlow,l'.' AlMeK51onz /)0( Additional Increase in Building Value $ By signing below, I (printed name) Permit Fee Due $ co) e, rah (;-> Additional S.F. affirm the Revision is inclusive of the proposed changes. Signature of Contractor/Agent (Contractor must sign if increase in valuation) (Office Use Only) Approved _ Denied Revision/Plan Review Comments Department Review Required: Building Planning & Zoning Tree Administrator Public Works Public Utilities Public Safety Fire Services Date Not Applicable to Department Reviewed By `�-�6-lg Date 4,- " IVEP CITY OF ATLANTIC BEACH s 800 Seminole Road iAtlantic Beach, Florida 32233 REVISION REQUEST / CORRECTIONS TO PLAN REVIEW COMMENTS Date q/10/)101Z Revision to Issued Permit Corrections to Comments IV/ Permit # FOO L 19 - 0033 Project Address eac Contractor / Contact Name S iti OLVIL S P aS Phone 9 0q- 21+ ( -2—(,1(, Description of Proposed Revision / Corrections: Email 4�GL►' c�Sl,� rc�s►�C2.'�0�5 . rle Permit Fee Due $ n � asev►►te-►`� - �, i P.lils � ov�� Additional Increase in Building Value $ Additional S.F. By signing below, I (441c"o K'- 116(1 affirm the Revision is inclusive of the proposed changes. (printed name) Signature of Contractor/Agent (Contractor must sign if increase in valuation) Date Approved _ / Revision/Plan Review Comments Department Review Required: ildin� Tre inistrator ubli Public Utilities Public Safety Fire Services (Office Use Only) Denied Not Applicable to Department Date BUILDING INSPECTION DIVISION �t+l lick Florida Begins. REVISING ACTIVE PERMIT FORM DATE: 9/10/2018 TOR NAME- LAMOLINARA ADDRESS: 1883 ATLANTIC BEACH BLVD PERMIT NO: POOL 18-003 (BUILDING PERMPP) CONTRACTOR: SURFSIDE POOLS & SPAS PHONE NO: 904-246-2666 FAX NO: ARCHTECT/ ENGINEER PHONE NO: FAX NO: BUILDING PLANS EXAMINER; REVISIONS FOR: PLEASE INDICATE BUILDING YES LANDSCAPE YES PLUMBING YES FIRE MARSHAL YES MECHANICAL YES ELECTRICAL YES SUBMITTED BY: MARCUS MEDLOCK PLANNING and DEVELOPMENT DEPARTMENT 214 N. Hogan Street, Room 273 Jacksonville, FL 32202 Phone: 904.630.1100 1 Fax: 904.255.8552 ; www.coj.net COMMENTS NO YES NO NO YES NO NO YES NO NO YES NO NO YES NO NO YES NO SUBMITTED BY: MARCUS MEDLOCK PLANNING and DEVELOPMENT DEPARTMENT 214 N. Hogan Street, Room 273 Jacksonville, FL 32202 Phone: 904.630.1100 1 Fax: 904.255.8552 ; www.coj.net syLar City of Atlantic Beach Building Department l 800 Seminole Road Atlantic Beach, Florida 32233-5445 A U93 9 2'1")' Phone (904) 247-5826 - Fax (904) 247-5845 .. E-mail building-dept@coab.us City web -site: http://www.coab.us APPLICATION NUMBER (To be assigned by the Building Department.) Date routed: O Z APPLICATION REVIEW AND TRACKING FORM Property Address: 12 9 3 A`Hotti-f' c eCi.G/'1 Applicant: -SLl jr4 & iJc 'Poo s Project:'Poo/ Department review required Yes7 No Bu' tannin & Zonin Tree Administrator Public Wor Public Utilities Public Safety Fire Services rRe iew fee Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING & ZONING ' Reviewed b : Date: TREE ADMIN. Second Review:A pp roved as revised. []Denied. [-]Not applicable PUBLIC WORKS Comments:. PUBLIC UTILITIES PUBLIC SAFETY Reviewed by:. ` Date: FIRE SERVICES Third Review: ❑Approved as revised. []Denied. []Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 PUBLIC WORKS PLAN REVIEW COMMENTS Date: 9/7/18 Applicant: Permit #: POOL18-0033 Email: Review Status: DENIED Property Owner: Site Address: 1883 Atlantic Beach Email: CITY OF ATLANTIC BEACH Department of Public Works 1200 Sandpiper Lane Atlantic Beach, FL 32233 (904) 247-5834 Surfside Pools Bary@surfsidepools.net David Lamolinara Not Provided THIS PLAN REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS Correction Items must be submitted to the Building Department at 800 Seminole Road. Submittals that respond to only one or a few correction items will not be accepted. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions must be submitted to the Building Department and must respond EACH department review. PUBLIC WORKS CORRECTION ITEMS: �P • Provide detailed plans of pool and deck. VED PUBLIC WORKS CONDITIONS OF APPROVAL: (The following comments will be printed on your permit as Conditions of Approval) • Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (247-5814) to request an Erosion and Sediment Control Inspection prior to start of construction. • All runoff must remain on-site during construction. • Pool — Wellpoint (if used) must discharge into vegetated area 10' minimum from street or drainage feature (swale, structure or lagoon). A separate Pool Permit is required. • Roll off container company must be on City approved list (Advanced Disposal, Realco Recycling, Shapell's, Inc., Republic Services, Donovan Dumpsters). Container cannot be placed on City right-of-way. • Full right-of-way restoration, including sod, is required. • All runoff must remain on-site. Cannot raise lot elevation. Scott Williams, Public Works Director swilliams@coab.us / 904-247-5834 Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with "clouding". The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud. The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with revisions shall be inserted into each set of drawings. The original sheets must be clearly marked "VOID" but are to be left within the set of drawings Complete new sets of drawings will not be accepted ADDITIONAL ITEMS MAY BE REQUIRED DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW. Page 1 of 1 O:\Public Works\ADMIN\PLAN REVIEW COMMENTS\POOL18-0033 (Surfside Pools).docx / SITE PLAN LOT 55 AS SHOWN ON PLAT OF ATLANTIC BEACH COUNTRY CLUB UNIT 2 AS RECORDED IN PLAT HOOK 67. PAGES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FL. GRAPHIC SCALE ______._. -:iRYE 'AALE TO Com" 28.87�- rn � � r w � rr � w t0 U t DENOTES PROPOSED WOOD DENOTES PROPOSED CONCRETE DENOTES PROPOSED PAVERS DENOTES CHEMICAL TOILET DENOTES FUTURE 4- TREE �i - vrnu+ Niflp�xdc a a :• •a° eAapv .mart m wA..w rxcn. NxaaNOIrLE_ta..I Al Los. 'n rax nixes-.nmr5s .vr�a ar ro.r m n. rEET — c.a.cE d aa.:sxc 'F.P \ F.P ARR, r7n'19• cfiC�R ELF.vnn<>u MUSt RE 2.' .fiOYF C -.m q(eLaAL.e01F4 i w�im.•ia uiy�+wm"xs �a'u�it nw¢n a x.aa ee� r •s ar�xc sr.�'v-E TME L.xvs .•dx xcaed ;a rRopD Nva v .s pExrrn a M nom rs,a.xm r.+ x.n t<. a . nan naw<w does, v.rtw.uxr. a vmv, x nem zo44 4xor. w ds m RODn uM�S R x[nEd ,wE e.1'p pr nom• rrs SxOUL �? n,[ CxaM.wr'4 Rom .tu4 u.x.f2u(x�xf>pe`Dm. +EpnMxUm mtAY' 4Or�e4 ory ii M1UM' af.cw •H aRx uxmadmro ngnpwnOxx d uRira.4 ! wn wxiPm�.l�saaR Orton,n e..Db -Xx E6E �•.VOt�d �xMerlFw �xdN.MM MDfo r0 rA• xEPoar K vn;aeA._o wW; r.5 xai .uMMblEn er9!K. 9wixn 4pIKRlx x Exnecs wnm DrwD.w .s ExR.xuxc :ro M eA1 x.nlxacermcnu. �.M 11 Mwr• aMA.v uxc�+.w,n ! xo. rraosn S. urY up MIERM M,MmMi 10 rltt.ND4 Mf. I•rtuw .np �MMSTMert. o. M4 9R ft 4 0M..mf M AM9 4 0E9L>bBFD. �• t3 x0 ..p2 m n wt 2pw.q �(DOu a- ExWuex.xSS ODRm Mary .M .x. �I.aA.*v 11[9a.iry0 n(a[ryry .5 .br +w .��5 nflDen x.gi.�5 on .m.4�.nwN iixES a .v. r'EOC'nN. cr. rt. a[adw.. A incx .mxC.. aWap. uw± ryr•ngrAx d nN9�ei - is e.am d wvc+L .m mwr v...,cs A. RAFT r .on .mit a.. 'F.S . u. n[c '•a5 c utn. rwvi- [5 .r.Ea nmsnrY xoEFJ. -. fl.¢pvc 5 x0 ta. .Ir�3umay. ' yew- < am n raNw .SED. :,xx5 rxE. .nE s.ur. na _ N d un s'eR'.> axwcui rt -A= ro na a a x Noar w x: ea. narnd n mEr+A<x nwa. nr.xsi xs w.,4. me w..:�xd .mN, a e5n ta. ar eeEs rt. u rtmrcuwc y d Er- .P ./ M. i wAM... Ar wd ON.a�r rlx. .. 0 ♦ nm E.SSwwt D• a. x.OF. awna5E5 {v/}APPROVED { } DENIED rrxd ! SMD NY F MprD .dam { } NOT APPLICABLE TO DEPT a>'rwx N aEMxy .rt nx+ xca sa rtM i�niF ii �roDMmacl P�ARm FOR:RiVERSIDE HOMES CSRTUM TO: RIVE 6: BARTRAX TRAIL 19URVSYING. INC. LAND sONTslOHB — nILKICIM — IAM DS/HlpPEM ew�o6ruef9 /�'\� 1e01 comm ROAD ala sorts No. toe vos) 8ea—asss i� " :' •-sLIM Gzm cows prim . n 3ma FAX (Dos) a!�-2Zae CLNrVICATs OP AOTHORMATION LH /e l g COPTSIOHT 7. Role FRCRr CFRT t sen NOTATION s'T•'..�Z�i'7+•ir•r���eA'^ BPit r- x».wn p x� .n AqernT tl Rnt _ 'Fu.f.v.I.aDcdo: IdE X (N/A) fl w..xcL5 120077 0.064 a/s /la mwww 220 q •BNq: N/A �_�ss ,,,,yy,,,,,,��,,��+• t a y t N A NLA m r a �e.t n is o oA1E' to/20/14 aNt ElG w]Ra t'puR�F!FC MAP (q (}NwL�Y gGNE(+ Ine r.1nt namatl ereori ane inn a•»y map ontl •spat Y tna copin eneronr ars not wlk rltx0ut Ms elgnaturn bntl pap,EOr NO. pF.vr9M- _ ....__.../A _._...__._......_......_..__ me mq!noI rcix0 »oi of a Fla�tic �kn^»tl wrveyn• awe e 't+'JMAS R HUGHES. ^'^Foes i3N-11-0.7y R.:.. S. `;7 . OE ILORiUA. LICENSE NUM0E4 .5 3507 d.wM 9�^. sTx P+FCxFD e`^ 0eG SHF.'___I _ e^ ywv x• IN rm . _. . 1 inch s 30 it. :Mn{:R�IUL)+ ceatuacE ai%kN p h T .J 4 F . _... _,. _". i sa ITi ear o eve 1 jW 1n Ti fk 6S 4a _ QAC v Pl1:LUINC, CO\'F.'R4GE r{1EL11C1 �5 Saa COHa D Se ids io. f i 4n 6. 5a. r YOE L OAC J S 10.84' AIXSl 4 4 .+R' \ it / fn5fa 0110 S0 11, e0lS Sa E�' IrtEi�" \� e a sa. \ \ .9 TO Com" 28.87�- rn � � r w � rr � w t0 U t DENOTES PROPOSED WOOD DENOTES PROPOSED CONCRETE DENOTES PROPOSED PAVERS DENOTES CHEMICAL TOILET DENOTES FUTURE 4- TREE �i - vrnu+ Niflp�xdc a a :• •a° eAapv .mart m wA..w rxcn. NxaaNOIrLE_ta..I Al Los. 'n rax nixes-.nmr5s .vr�a ar ro.r m n. rEET — c.a.cE d aa.:sxc 'F.P \ F.P ARR, r7n'19• cfiC�R ELF.vnn<>u MUSt RE 2.' .fiOYF C -.m q(eLaAL.e01F4 i w�im.•ia uiy�+wm"xs �a'u�it nw¢n a x.aa ee� r •s ar�xc sr.�'v-E TME L.xvs .•dx xcaed ;a rRopD Nva v .s pExrrn a M nom rs,a.xm r.+ x.n t<. a . nan naw<w does, v.rtw.uxr. a vmv, x nem zo44 4xor. w ds m RODn uM�S R x[nEd ,wE e.1'p pr nom• rrs SxOUL �? n,[ CxaM.wr'4 Rom .tu4 u.x.f2u(x�xf>pe`Dm. +EpnMxUm mtAY' 4Or�e4 ory ii M1UM' af.cw •H aRx uxmadmro ngnpwnOxx d uRira.4 ! wn wxiPm�.l�saaR Orton,n e..Db -Xx E6E �•.VOt�d �xMerlFw �xdN.MM MDfo r0 rA• xEPoar K vn;aeA._o wW; r.5 xai .uMMblEn er9!K. 9wixn 4pIKRlx x Exnecs wnm DrwD.w .s ExR.xuxc :ro M eA1 x.nlxacermcnu. �.M 11 Mwr• aMA.v uxc�+.w,n ! xo. rraosn S. urY up MIERM M,MmMi 10 rltt.ND4 Mf. I•rtuw .np �MMSTMert. o. M4 9R ft 4 0M..mf M AM9 4 0E9L>bBFD. �• t3 x0 ..p2 m n wt 2pw.q �(DOu a- ExWuex.xSS ODRm Mary .M .x. �I.aA.*v 11[9a.iry0 n(a[ryry .5 .br +w .��5 nflDen x.gi.�5 on .m.4�.nwN iixES a .v. r'EOC'nN. cr. rt. a[adw.. A incx .mxC.. aWap. uw± ryr•ngrAx d nN9�ei - is e.am d wvc+L .m mwr v...,cs A. RAFT r .on .mit a.. 'F.S . u. n[c '•a5 c utn. rwvi- [5 .r.Ea nmsnrY xoEFJ. -. fl.¢pvc 5 x0 ta. .Ir�3umay. ' yew- < am n raNw .SED. :,xx5 rxE. .nE s.ur. na _ N d un s'eR'.> axwcui rt -A= ro na a a x Noar w x: ea. narnd n mEr+A<x nwa. nr.xsi xs w.,4. me w..:�xd .mN, a e5n ta. ar eeEs rt. u rtmrcuwc y d Er- .P ./ M. i wAM... Ar wd ON.a�r rlx. .. 0 ♦ nm E.SSwwt D• a. x.OF. awna5E5 {v/}APPROVED { } DENIED rrxd ! SMD NY F MprD .dam { } NOT APPLICABLE TO DEPT a>'rwx N aEMxy .rt nx+ xca sa rtM i�niF ii �roDMmacl P�ARm FOR:RiVERSIDE HOMES CSRTUM TO: RIVE 6: BARTRAX TRAIL 19URVSYING. INC. LAND sONTslOHB — nILKICIM — IAM DS/HlpPEM ew�o6ruef9 /�'\� 1e01 comm ROAD ala sorts No. toe vos) 8ea—asss i� " :' •-sLIM Gzm cows prim . n 3ma FAX (Dos) a!�-2Zae CLNrVICATs OP AOTHORMATION LH /e l g COPTSIOHT 7. Role FRCRr CFRT t sen NOTATION s'T•'..�Z�i'7+•ir•r���eA'^ BPit r- x».wn p x� .n AqernT tl Rnt _ 'Fu.f.v.I.aDcdo: IdE X (N/A) fl w..xcL5 120077 0.064 a/s /la mwww 220 q •BNq: N/A �_�ss ,,,,yy,,,,,,��,,��+• t a y t N A NLA m r a �e.t n is o oA1E' to/20/14 aNt ElG w]Ra t'puR�F!FC MAP (q (}NwL�Y gGNE(+ Ine r.1nt namatl ereori ane inn a•»y map ontl •spat Y tna copin eneronr ars not wlk rltx0ut Ms elgnaturn bntl pap,EOr NO. pF.vr9M- _ ....__.../A _._...__._......_......_..__ me mq!noI rcix0 »oi of a Fla�tic �kn^»tl wrveyn• awe e 't+'JMAS R HUGHES. ^'^Foes i3N-11-0.7y R.:.. S. `;7 . OE ILORiUA. LICENSE NUM0E4 .5 3507 d.wM 9�^. sTx P+FCxFD e`^ 0eG SHF.'___I _ ECEIVE ITY OF ATLANTIC BEACH 800 Seminole Road SEP 2 7 2018 Atlantic Beach, Florida 32233 (? Z 7 68 REVISION REQUEST / CORRECTIONS TO PLAN REVIEW COMMENTS _ fD6Ot' I S -.DD33 %1 d Date :IZf Revision to Issued Permit Corrections to Comments_ Permit # )S' 00 3 Project Address 1 p iS D". (A -H a ,tic - Contractor / Contact Name J O k y� C, -SC-6 Phone Gw7 ;� q (o - Z 6 (o 6 C 117 Description of Proposed Revision / Corrections: surve Li Email� S r&g5 ile, Ono k- , co bV>. �"jGt rC L4.5, 0 -�' Si JC P00 1 S , Gower r�ir+�iL'N.S�O`ls I Additional Increase in Building Value $ By signing below, I (printed name) Permit Fee Due $ rwerayQ- Additional S.F. affirm the Revision is inclusive of the proposed changes. Signature of Contractor/Agent (Contractor must sign if increase in valuation) Approved Revision/Plan Review Comments Department Review Required: Building Planning & Zoning ITre rator ublic Works s Public Safety Fire Services (Office Use Only) Date Denied Not Applicable to Department evie ed By ...... ...... _ _ _ __ _- -- 1,a� 1' ����'_y � _�5 �,�� _rz y �1/ Q Q/1 /� �/ o y76�o 3' 0" MINIMUM 3" TEE - 3"PIPE 3" PIPE 3" X 2'/z" RED. BUSHING E-2'/2" TRUNK TO EQ. LEGEND = 40OW 120V WHITE LIGHT Eb = WALL RETURN = CMP SKIMMER = STUB OUT FOR CLEANER ® = UMBRELLA HOLDER O O = NOVA DRAIN !V r r POOL 30'-0" X 15'-0" W/ STUB OUT FOR FUTURE CLEANER AND 3 ALL RETURNS POOL W/ STUB OUT FOR CLEANER & WALL RETURNS FILTER SCHEMATIC (NTS) ■ INSULATED BOND WIRE IN CONDUIT FRO LIGHT NICHES THROUGH DEK BOX. LIGHT - GF I PROTECTED. PLUMBING LI E FROM POOL SKIMMER TO PO L EQUIPMENT FLOW SWITCH AQUA PURE 1400 EXISTING STOOP 0.0. -8" NEW DECK TO I RECEIVE STANDARD W PAVERS ALARMS UP TO POOL SAFETY CODE. STANDARD TIE ON +12" 1 ; M v 1 0 1 �NC� • DIMENSIONS TAKEN FROM 1 z OSE BIB 1 1 1 1 PLUMBING LINE FROM POOL 1 1 1 1 $ z 1 T-0" EEF 5'-0" EQUIPMENT — — — POOL 1 EEF N G._'. -_c M L:J ALARMS UP TO POOL SAFETY CODE. STANDARD TIE ON +12" 1 ; SEE DETAIL 1 0 1 GRADE DIMENSIONS TAKEN FROM 1 1 OSE BIB 1 1 1 1 PLUMBING LINE FROM POOL 1 1 1 1 $ IN DRAINS TO POOL 1 T-0" EEF F 11 11 1 11 11 1 UMBRELLA 1 �= ANCHOR 1 AN UNDERGROUND BONDING CONDUCTOR MADE OF A SINGLE #8 AWG BARE SOLID COPPER WIRE BURIED TO A MINIMUM DEPTH OF 4 INCHES TO 6 INCHES BELOW SUB GRADE, AND 18 INCHES TO 24 INCHES FROM INSIDE THE WALL OF A SWIMMING POOL OR SPA WILL BE USED. Florida Building Code 51t^ Edition (2017) Residential Conforms to Chapter 42 GRADE & 2014 National Electrical Code • NO OVERHEAD ELECTRIC IN POOL AREA • NO UNDERGROUND UTILITIES IN POOL AREA • FINISH GRADE TO SLOPE AWAY FROM POOL • VGB COMPLIANT MAIN DRAIN • DRAINAGE DETAIL — FINISH GRADE SLOPE AWAY FROM POOL • GROUNDING & BONDING DETAIL THREE-TIER RAISED SAFETY BARRIERS: 24" H ER DENT SCREEN ENCLOSURE AND WATER WATERFALL _GLASSTI EON FRONT, ALARMS UP TO POOL SAFETY CODE. STANDARD TIE ON +12" SIDES a BACK ; SEE DETAIL J D W -7" 1 GRADE DIMENSIONS TAKEN FROM r EDGE OF WATER TO OSE BIB 1 1 PROPERTY LINE 1:4 �• �;; 0YT=P W M81MCa$ .+ 1 1 _ a WTSIG.FI3fULIJ�413E 1HEATER EXISTING A/C UNIT BARE #8 BOND WIRE ATTACHED TO POOL STEEL +611 REVISION: 09-10-2018 MCM DECK SIZE REDUCED DUE TO EASEMENT DIMENSIONS ADDED THREE-TIER RAISED BEAM DECKING WITH 24" SHEER DECENT WATERFALL GLASS TILE ON FRONT, STANDARD TILE ON SIDES AND BACK FRONT VIEW 1 (� FORM PLUMBING LINE 24" FALLS..X ` 28" NOTCH FOR PAN \.6 +12" 1 ; GRADE J D W 1 � - r N OSE BIB 1 1 1 1 PLUMBING LINE FROM POOL —ICT BOX 1 1 1 IN DRAINS TO POOL Q EQUIPMENT — — — POOL 1 1 ~EQUIPMENT 1 1 1:4 �• �;; 0YT=P W M81MCa$ .+ 1 1 _ a WTSIG.FI3fULIJ�413E 1HEATER EXISTING A/C UNIT BARE #8 BOND WIRE ATTACHED TO POOL STEEL +611 REVISION: 09-10-2018 MCM DECK SIZE REDUCED DUE TO EASEMENT DIMENSIONS ADDED THREE-TIER RAISED BEAM DECKING WITH 24" SHEER DECENT WATERFALL GLASS TILE ON FRONT, STANDARD TILE ON SIDES AND BACK FRONT VIEW lLL Q a z O Q J 00 000 00 N m O 00 J U J N M N Z = M J Q IL U W = _ m U UUj Z mw Z rn 00 J J CO Z z O 0 U) N N W W > y W Q u (n ADD 4" X 4" POST TO (� FORM PLUMBING LINE 24" FALLS..X ` 28" NOTCH FOR PAN \.6 +12" lLL Q a z O Q J 00 000 00 N m O 00 J U J N M N Z = M J Q IL U W = _ m U UUj Z mw Z rn 00 J J CO Z z O 0 U) N N W W > y W Q u (n Y 00 U o 00 r N J D W c N � - r N fn > o� W > Q LLI LLI Z Z Q W Z Z 'S Q 0 U Q Z O w to - U a lLL Q a z O Q J 00 000 00 N m O 00 J U J N M N Z = M J Q IL U W = _ m U UUj Z mw Z rn 00 J J CO Z z O 0 U) N N W W > y W Q u (n SITE PLAN LOT 55 AS SHOWN ON PLAT OF ATLANTIC BEACH COUNTRY CLUB UNIT 2 AS CORDED IN PLAT BOOK 67, PAGES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FL. GR PHIC SCALE 30 0 15 30 ( IN FEET ) inch — 30 M M ASUREMENTS ARE FROM POOL WATERLINE TO PROPERTY LINE _SALE: 1/30" = 1' ARRIERS: FENCE ?a ALARMS 5'g6� 2s.61• \ 48.00' \ � (A 10 rn J \ W o Ar,l 7.66' N4 ® DEN TES PROPOSED WOOD t4 0 DEN TES PROPOSED CONCRETE DENOTES PROPOSED PAVERS DENOTES CHEMICAL TOILET �i -- DEN TES FUTURE 4- TREE tae a NO Ar.�r AEIASEO ON TME aNTERLOX OF ATLANTIC BEACH ORnC AS ENG S0911'S3-E. 3Lv mss 9i0rt1 HEREDN ATE BASED ON NAW ISOsThe HLTREON LIC 111laN FLOW ZOFE 'x, AS DUlcTTD ON M rtooD N51AAfICE RATt YAP (ra. S COMMOFFPOTr OF f3R . MAPOOD ZONES SWWN ON T"S TE PLAN S AND ME fOR� ONLTED. aft 1 �ITKi HE rI ORMA1tON MIO OQJKArlom'f ON "ITS SITE PLAN ARE VALID ONLY FOR 0 TES UP TO MID "CLUONO AE DATE or THIS Sort PLAN. THERE WAY HAVE GM SuBS&OLENT REVISIONS MSR ON REPOSITORY DATE IIIAT tWq SAID wfoRWAWc T. Cllr Or MS oft" BE MADE TO THE OMHA"TT'S FLOOD PLANE YANAGEIENT EACK 4 1L00D YAPS /iREON ARE BASED ON NAUO 1916. s. NO FOUROATIONS OR UTtUTWS ! No IMPROVOJEMM OTHER THAN MDSE 9tOM1 %TAE LOCATED UNDER THE SCOPE err Fres SITE 6 ADDITIONS. nQiS AND/OR ANY WRITTEN INFOPMATION ADDED TO 1/115 MAP '01098 REPORT IS PIM"SrEll AND 1S NOT Aut"OlItuo er SONNG SlAvEYOR. 7. TICS WAP IS N r0 NE VIEWED AT A SCALE OF I' -3(r OR SMALLER 6 ENTRIES t PA DEPICTED AS Exixom0 s1To INE BUILDRIG REsmeTON Lrs15 MOST REMAN U"COVpMD f NOT EN0.OSED S. UPLAND OL:Y ADJACENT TO wETtHMV.oTHEREOF. NATURAL. VEGETATIVE. APO UNCISAAMED 10 04MEN'90NS N FEET AND DEOYAL ANTS tt. 9AT SIM K Otey FOR Tic L.AFIDS As DESmew IT IS "Or A CERTIFICATE OF hTLL ZONING. EASEMENTS OR FREEDOM or EHCANCES. IX 12. SITE PL *AS mar 1NiENOCO TO DEIAEAiE OR OEfet ANY tuETLANOs. ENMRgNME14TALLr SENSPDV£ AREAS. stOU/F AItf tatBILI TINGRP�nOKA IMSR(Of ANY b icitAL STAoo? TW ��r 0a ���60APO. ANO tOiie�►1 QI oAND rHER t?LnTr 13. UAC55 A ARSON IS NAGE. WEASUED OEANNGS ANO DISTANCES AI(E OQ111CAL Mm KAt VALLIf.S. 14. TWS SITE PL IS BASED ON INFORMATION AS PACUM By nE CUENr ti 01,01,0640MA;sik01E/10+T TIES AS DEPICTED IIEROOM ARE POOr01RRJIA TO THE PARCEL PIOPOLfr LINES U4ES5 OhtRAI`Z NOTED. ALL DES ARE SHOWN TO IRE FOUNOADON. 16. PLEASE ro THE PLAT FOR ADDITIONAL am MAT WAY AFFECT Ails LOT. 17, THIS IS NOT (KAROARY UPYEY. 16. PUW. StDE S DEPICTED .HEREON AK BASED ON THE CCRSIRUCiIQL PLANS THEY ARE 5}101x1 FOR NfOft"110MAL PURPOSES ONLr ANO ARE N T TD BE REUEO UPON FOR CONSIT=TION. FOR CORRECT LOCATION ANO/OR 00 60111 Tt1 m TO TLE MOST CuRQ01T SET Or TIWCT10h PLANS itIM IS A MANNAN 271 SLOPE ON ALL 4DE"LUX1^ ALL SIDE"W" AM ftnTWORH SHALL. AT A VDIMAIL dApt7tT ouvAL t011ltY AND ADA STAhOARCS CROSS POPES SHALL BE RO YORE THAN 21 THE PORTION OF THE 51DEMALIL @AIKVEASES TMOUOI THE ONVEjMV APnQ1 SHALL ALSO WEFT 1M RST. ALSO. PLLAU 1101E MAT UTILITIES (Yfipt )CS. VAL.VCS. CTC) SHALL NOT EE vMALLiD MTraN THE SOCOAUC 19 OSAIM S TURES OET4CRO YAr YAR' e1 S1ZL REFER ro ENDINIX) INO PLANS FOR cORRCCT OsEMA0N5 20 A/C ADS ST MAINTAIN 2- AWAY FROM ANY PROPERTY LAE AM CAN NOT ENCROACH INTO A ORAfmA4E EASEMENT DUE TO OR RCM ON A SIC PLAN - NEW SITE PLAN (5/23/17) (OOM/OBG) PREPARED ,FOR: RIVERSIDE HOMES 41b y / \ , 11.41 MPEF .LOT C �•�`O + qs Y 5.00' 14.23' 54 'EWAY/SW: ERED PATIO: L/COPING/DE >,L: 10,6 2,11 1,06 = 35.22% PER An, n mSN FLOOR ELEVATION MUST BE 24' ABOVE CRAOE "SETBAOM" FRONT - 20 FEET FROM FACE OF CARACE TO BACK OF RR.11T Or MAY AND I$ FT3T FROM BIALOWS FACE CR PC" TO BACK Or Rf6HT OF WAY. CACO'r CORMR/OoUo XJ rRONTAOC LOTS. rook WOCH TME NCh-ADDRESS MMT/SiOE 1Ms•uM rAM SNAtt BE 10 FEET FROM GARAGE OR BUIDING FACE t0 BAOt Of fb01T of tMr. BREAKDOWN500 CURVE TABLE CUttlt RADIUS ARC LENOTII 01%0 ORCCTICN CROTID LENGTH ORTA Cl(P)5000 3780 NS'54'5" 3672 43MVC2' CW) 170.00 1 113.14 1 1416.24171► 111.06 30'OT56- "SETBAOM" FRONT - 20 FEET FROM FACE OF CARACE TO BACK OF RR.11T Or MAY AND I$ FT3T FROM BIALOWS FACE CR PC" TO BACK Or Rf6HT OF WAY. CACO'r CORMR/OoUo XJ rRONTAOC LOTS. rook WOCH TME NCh-ADDRESS MMT/SiOE 1Ms•uM rAM SNAtt BE 10 FEET FROM GARAGE OR BUIDING FACE t0 BAOt Of fb01T of tMr. BREAKDOWN500 TOTAL LOT AREA 10.826 Ser. Ft R TO t31RB 488 So. ft. OR053 e00 1. 14t. OUNOATION SLAB 3.826 Sao Ft. 881 Sq. iL 65 Ser Ft REA r O fLft GARAfhf B Sq. FLR SLAB SERVATKIN 0 Sp FL NET efYf AREA 4:1193 - 6.121 Sq, ft. cm=nn To: RIVERSIDE HOMES IMPERVIOUS COVERAGE sOM MOUS q rL I LOT Ser. FL S 4.639 S6 fl 101126 Sq. f t 42.ax BUILDING COVERAGE COHERED Sq IT LOT Sq. FLz 3.077 Sq. rt. I ICA36 sq Ft. 8567[ : 'aIwWon ro "'°""M-�' "Me-A.�'.-..-"'... BARTRA� TRAIL SUR'`TEYINGo INC. .lspsl oust er w - ihiw Nur 1Aw . tomos •..w r ..ww..rr. �.' ...w1...wT ..-..L ........ «..... LAND SURVEYORS — PLAN m — LAND DEVEtAP1LENT CONSULTANTS 1601 COUNTY ROAD sib SUM NO. 1OCE804) 564—$224 ....I.I . ..e.1K - 11041113 GRB6N COVE SPIGNG3. FL um FAX (906) 2e4-2208 I > ax. ' Nw w �rw�s e.. p.s .sumo r..w• CREFjCATE OF AUMOMATION 12 #M1 COPYWORT 0 8018 � .� •..nr A.rr.. NOTATION. rMAA1. ROOD ZONE X (N/A) .rovm 1 HEREBY CERTIFY. that this survey graphically represents The survey hereon -os mode without benefit of abstract or M/ ELEVATION- tram.11,c. the results of o field survey made under my responsible search of title. and thetefore the undersigned aid SorPANT1 direction and complies -ith the latest Standards of rroa sw.eylnq me&e no 0"timeoUane rtwdina Information 120077 o406N B/3/13 -WASInaAw ooesla Practice for Survey% as promulgated by the Florida State snaun or not shown hereon Pertatming to easements, claims ss- Aa :4$iiSitYweO , Board of Professional Surveyors and flappers. Choptef of easements. R'hgfds-o(-woy. setback I'hnee. ovedaps. ,mom Pa. .!!M �_ ►.�„ 51-17 FAC. Pursuont to section 472027. Flaido BatmWory Line di30ute5. agreements. rewvotions of other N/A . Lw.h1s statues, subject to all notes and notations shown hereonwRor molten which may appea in the obstroct, or search . wrNM1 M .NMI P4MbM� K.II® ffr eYtI1MrtY/A :4s urwh OATS ' ...,_..� � N/A N/A This curves is eP res aHd certified For the exclusive use of 10/20/16 1'=Z.30' F1EL0 WORK COYPtETEO MAP ORICWALLY SIGNED the client namededhereat and the survey mop and report of p _ p� + • "' the copies thereof are not Veld without the signature and PROJECT MO.: REVISION: \ N/A the orlginal raised sed of a Florida licensed surveyor and 1349-16-035 A THOMAS P HUGHES, P.LS maw \\ STATE OF FLORIDA LICENSE NUMBER LS 3507 DRArt er: STH E3fECKED DIY: 08G SHEET 1 OF__L_ AS Sao SITE PLAN LOT 55 AS SHOWN ON PLAT OF ATLANTIC BEACH COUNTRY CLUB UNIT 2 RDED IN PLAT HOOK 67, PAGES 132--137 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FL. APHIC SCALE 0 15 30 ( IN FEET ) I inch - 30 fL EASUREMENTS ARE FROM POOL WATERLINE TO PROPERTY LINE SCALE: 1/30" = V IiTTi DEN DEN DEN D DEN j - DEN Lx.,tit:aN- .'1Er. t. GEARViGS ANE 2 CRAINAGE CLJ ir4 LANOS 51 MAt-:A 129077, ThE F.E.M.A ill VALID Grit EER THIS DATE 1HAT 4EPOSTCAY, DEP 4 ftoco NAPS, S. ND UNOCAMC or Tits SITE PL, L ADoYMN;, OE AtlNCRIZED UY 7 TILS UAP is e ENTnES a PA 3 uPtAAD ev"I 10 DIMENSONS i II tits ult PU v.CUM'J4At10E$, 12. THIS SITE PL, HAVIATS CR ,Ay AND ANT Luba11 13. 0?4C % A CC 14, TN:$ S1ri PL to DULD IND ANC NOTED. ALL DUtll 16� PLEASE REFE1 17. Ties IS Not 16. PL,.%W- WEI OF&Y AND ARE N CURRENT SET Or ATAUnUAKM TME %OEWALN * unuTics (uMA 19 ORmmAGE Sn A COMMUNITY DFvE��PM N/ENr D'e �D 11.47' 7.66'—. \ P,AN BARRIERS: FENCE ALARMS 4 57 oo`(p5 z L61J 48.00' `'3 \ t L, '. 1 g\ , 'fit i Lw Ln } 1 5 10.1 rn �va LA 1 t� V tfJ l� ,-- _ 14.23' '07'w s.oa' 9. ,,OT 54 IMPERVIOUS CALCULATIONS TOTAL LOT AREA: 10,672 SQ FT HOUSE: 2,115 SQ FT DRIVEWAY/SW: 1,065 SQ FT COVERED PATIO: 585 SQ FT POOL/COPING/DECK:868 SQ FT TOTAL: 3,765 SQ FT — = 35.27% I )TES PROPOSED WOOD )IES PROPOSED CONCRETE )TES PROPOSED PAVERS )TES CHEMICAL TOILET )TES FUTURE 4' TREE IL'" ON THE GENTLIkUW OF ATLANTIC PEACH MILE AS UL043 b5'JI'S3"E DONS SHOVIN HEREON ARE OA= OM HAVO IS•3 IN NEAEON UE 1111194 FLOW ZW " A' AS CEACTiD ON THE. ROOD orsimA'nX IVMi RATE YAP (FIRM.) CCwry 1ft:1 itUN6£R 0406n. DATED. AItE 1. 2913. THE FLOOD ZOW-5 snowi CN T)qS 9TF FtAM A4£ SCALE* ufr OF NAPS Alm ARE top ronEricE cre.r. 111E FIR IL WCAMAIKIH AND 00a4Anott'S ON TtG SITE PLAN ARE LIES UP TO AA:O 1NCLUOINO THE DATE OF TW. SIZE PLAN. THERE MAY HA4E OM 11r40UEtHT 4tENs'w5 AtIm I StAPEASEDE SA10 D.FC0MA1)aC LNOI:.rf.; SHOULD BE MACE TO THE C0mumttr'S F11000 PLAUIE wmAMMEmt IWI10 OF FVUX WYMS, OfY Or AnNLTIC BEACH. 17YTtCfn HEREON ARE BASED ON NA%O IWA D FOUNDAnr)pm OR UflUritt Y NO nIPR043"m or," THAN TIaSC S1tOrN KAE LOCATED L"MR 90, S+Iy'E 'KMS A164/09 ANY Iia Ittl ;XF1, f/ATk1-% AtOM TO THIS MAP AAD/rR WW"r M PR(N;.E47M AND 95 NOT SC.V%c StwVEYOR. )IvM To U£ NE1i0 AT A SCALE OF V-30' CR %uALtLR. S DEPICTED AS EXIE'tXvG 04TO NE BIAtLaiG ICS14ICM14 LNAn MVSr Fr gn.-i uncota 7D * x401 ENCLOIED ADJACENt t0 WETLAND'S AAE rO ACMAr4 HAIURAL. >'EC.ETAT.L'T. AND Lmasni alEn 14 fUT AND O'ECMAL PA4TS THEAECF. t5 ONLY top ntt LAWS AS OESM ED IT IS NOT A C:RIOKATE CIF n1LE. 2VtaNG. iASTLAE1e1s Cw rREEDOM OF IAS nor V1TEMXD 10 DELINEATE CA OCTINC ANY %CTL.ANDS, E14MQCHIVENtALLY SMSITNE AREAS, 114DUFL KnONAL UNtS Cf AYY FT:L(RAL. StAfL AC*Qnµ OR LOCAL AGENCY. DaAtlo, Aha COMMu%44 op oTTiER UtnTY iE'.AA.IYN.' 14KtiEI1KM * Not TMC Rel" -e LAUt"r Or hit LAIOr.p,,e KA, 'AMID I IS MADE. MEA',I) MARNGS Not orSTAlKLS ANE IDENTICAL .4n1 rLAr VALVL5 IS BASES ON DMTDRUATICN AS PROMOM BY THE CL:FMt 1PR0+0IENI TITS AS DEPICTED JILREGNH An PFM"LvCUL.Att 10 TIC PAFeCLA j4ie,�CHTT UES 1AAL55 QTiLRNST. TIES ARE SWAN TO THE FOt,!NDAL'Ch V THE PLAT FOR ADMT1ot1AL ITEMS THAT MAY AFfECT iH5 Lot. el7UtMARY 'ALAiYEY. SS DEPICTED HEA& ARE BASED Cil THE CChSHRW.104 PLAN`; THEY ARE SNOW4 FC41 MFCAMATICYHAL Pt""OSE1. TO OE RELIED LOON FOR CXNSTTLCnCh. FOR CCAA£CT LOCATt O Are)/CA Di eCS)ONS FOER TO THE No;T Ti1RUC1tGN PLAN: TI'M IS A NAlWJU = SLCPC ON ALL .aDCWAUtS, W. «OEINALK AND RATSCfM 7tAJ- OtRRENT DUVAL COUNTY ALPO ADA STANDARDS DROSS SLCPES SHALL BE hO 1104E THAN 2L THE POROOH OF 1 TRAHS14RS£S 7"RoUGH THE 0k%C%AY APRCN SHALL A-00 MEET THIS P4CDLWXVMT AL!A PLEAU Nati t"AT ICES, VALVES, ETC.) SHALL HOT AE W.TALLED NTICN THE SIOC11rAD.K :TLWES W'lCnD MAY VARY TV 9ZE. FKFER To ENC441RriD PLANS FOR CCFMCr DIM NSICNS. MMNTAIN 2' AWAY FROM ANY PROPERTY UHF. AM CAN NOT ENCROACH INTO A DRAWAOE EASEMENT DUE TO 911: K.M - NFv SITE PLAN (5n.3,0; (UDN/OBG) RT RIVERSIDE HOMES 381 PER ARB. nmiStt FLOCK ELEVATION !MUST BE 24" ABOVE GRADE •-Aft)ALxS•- MONT - 20 FEET FROM FACE OF GARAGE to BACK CY A1G1T OF MAY A.Ib is FEET Facu BUILDING FACE CIL PCROH TO BACK OF wilt or wAy, ExClPT CCM"/DOuOu-fRoNf^lx LOT"., FOR Woof THE NON-ADOW", FitCTHi/StOE M1QW,W YAJtO SNAU. HE 10 FEET FROM GARAGE Gl VIALOM' FACE tO BA9 OF III T aP MAY. 500 RREAKOgWN CURVE TABLE TOTAL LOT AREA CURVE RADFJS A>rC LENOn1 0400 OALCTKN GICAO ttNGIN DELTA C1(P) moo 3760 N5'54'581 3672 ♦SDS'C1' i C2(P)Y 17000 11116 Nt674'17"1 11D .b SA 07"`b' •-Aft)ALxS•- MONT - 20 FEET FROM FACE OF GARAGE to BACK CY A1G1T OF MAY A.Ib is FEET Facu BUILDING FACE CIL PCROH TO BACK OF wilt or wAy, ExClPT CCM"/DOuOu-fRoNf^lx LOT"., FOR Woof THE NON-ADOW", FitCTHi/StOE M1QW,W YAJtO SNAU. HE 10 FEET FROM GARAGE Gl VIALOM' FACE tO BA9 OF III T aP MAY. 500 RREAKOgWN NOTn"W", The survey herean -uv mode ,.ithout ban fit of abolroct or TOTAL LOT AREA 10.626 Sq Ft RM To CLM 4883o. Ft. CrHOS3 500 ARCA 11,314 57 t. 1t ntYH�. FOUNOATTON SLAB 3.828 So, Ft, DRIVEWAY 991 Sa. Ft. AW WALK 65 Sq rt 917EwALX AREA 0 S4 ft. A/C PAD(S) b GARAGE =AM,CE DOM SLAG 9 Ft. —Mn/COhSCRvATh3N o :q Ft. ___. -4'.893-S4--Ft— 4.843`Sa--Fi REi Q011 ALRFA 6,421 Sq. Ft. REL—Q011—MU cEMFIED To: RIVERSIDE HOMES IMPERVIOUS COVERAGE tupertt'lou; sq f L I MAT SST FL %- 4,6" 54 rl. I ioA25 Sq. re. I 420x BUILDING COVERAGE CO%EM Sq Ft Lot S4 Ft. I % 577 s1 r/ 10,826 Sq Ft. 356% �..�. BARTRAM TRAIL SURVEYING. INC. w" LAND SURVEYORS — PL HERS — LAND DEVEWPUM CONSULTANTS "`•«••• 1501 COUNTY ROAD 315 SUITE NO. 106 OO4 26d -2224 -,`I,~•--•''"► `°'°"R•"" °• GRBBN COVB SPRINGS, FIA 92043 FAX 804 2841-22.08 C8R MCA72 OF AUTHORIZATION LB #69 1 COPYRIGHT a 2016 l HEREBY CERTIFY, that this ylrvey grarnhicdly repre.int^. the results of o field survey made under my respons;bte NOTn"W", The survey herean -uv mode ,.ithout ban fit of abolroct or ri.Am. FLOW ZONE, w/ nEVAr4W M (N/A) Xrectiu, one compliez with the tatnst StondordS of PfOCGCE fer Survey: MS prcmLdgoled by the Acrioo Stole *torch of title, and therelore the undertigned and Bortrom Trpa 1-rve„np make no hnrtif+rrllene reaar"o tnlormation PAPIEL NO, 120077 0406H 6/3/13 Board Of Professional Surveyon end )toppers. Choptef !Lown Cr not shown hereon ptytaining to easement*, claim* of easement:. A;9hts-of-way, setback lin!„ overlopa, .5J-17 F A C..: Pursuant t0 lection 472.027. fkrido '�1tue^., Boundary Line disputes. agreements. reservations or other N/A abject to dl note•.x and tictotlans shown hereon ;�mior matter which may appear in the Ob3troCt, Or search. N/A N/A �tl2K This i%ovey ,s prepared Lied Certified for the exclusioe use of DATE:. 10/20/16 SCAtE 1 -3, (.CLPIETEb NAP GRiGiNALLY SiCNEO the client Tarried hereon and the surv.y mop and report of tho Capies thereof are not valid without the signoturw and I""Cr NO.: 1R:NStON� the original raised wol of o Florida lictnzt4 surveyor and 1,349-15-:035A 'D HUGHES. P.L.S mapper LORfOA LICENSE NUMBER LS 3507 DRA%h UY. STN CHECKED 0Y; 000 SHEET 1 OF 1 -� S 0 , L`'000 00 irk A B I I ♦Aop♦• oG 3y � � ♦40 ♦I A �J► � \_ G t�`pG�iyO,p���C R c`,y� F.c� o► . 004 k AO V 3' 0" MINIMUM 3" TEE 3" PIPS _ 3" PIPE 7,\-3" X 2'/z" RED. BUSHING /2" TRUNK TO EQ. LEGEND K - 40OW 120V WHITE LIGHT 0) - WALL RETURN = CMP SKIMMER ll� = STUB OUT FOR CLEANER ® - UMBRELLA HOLDER O O - NOVA DRAIN r PERMIT PLAN POOL 30'-0" X 15'-0" W/ STUB OUT FOR FUTURE CLEANER AND 3 WALL RETURNS POOL W/ STUB OUT FOR CLEANER & WALL RETURNS FILTER SCHEMATIC (NTS) 10 U INSULATED # BOND WIRE IN CONDUIT FRO LIGHT NICHES THROUGH D CK BOX. LIGHT G CI PROTECTED. PLUMBING L NE FROM POOL SKIMMER TOP OL EQUIPMENT FLOW SWITCH AQUA PURE 1400 EXISTING STOOP 0" i 1-- 22' 4"1 1 -6" ■ 1 � ; 1 GRADE ,,--HOSE BIB 1 1 1 1 PLUMBING LINE FROM POOL I---JCT BOX 1 1 1 MAIN DRAINS TO POOL POOL—� — EQUIPMENT 1 1 EQUIPMENT 1 1 1 ---------- AIC UNIT BARE #8 BOND WIRE ATTACHED TO POOL STEEL +s" THREE-TIER RAISED BEAM DECKING WITH 24" SHEER DECENT WATERFALL TILE ON FRONT, BACK & SIDES FRONT VIEW ADD 4" X 4" POST TO FORM PLUMBING LINE 24" FALLS" X 26" NOTCH FOR PAN \_ +12" 3' AN UNDERGROUND BONDING CONDUCTOR MADE OF A SINGLE #8 AWG BARE SOLID co COPPER WIRE BURIED TO A MINIMUM DEPTH OF 4 INCHES TO 6 INCHES BELOW SUB CO N 0 LU GRADE, AND 18 INCHES TO 24 INCHES FROM INSIDE THE WALL OF A SWIMMING POOL OR SPA WILL BE USED. > Florida Building Code 6"' Edition (2017) Residential 0o w .= M > Q Conforms to Chapter 42 ui -22'8' -8" p Ili o Fw- m 2 GRADE & o `"— Z ................... 2014 National Electrical Code NEW DECK TO W °m RECEIVE STANDARD O • NO OVERHEAD ELECTRIC IN POOL AREA o PAVERS • NO UNDERGROUND UTILITIES IN POOL AREA �`�� • FINISH GRADE TO SLOPE AWAY FROM POOL • VGB COMPLIANT MAIN DRAIN z W 3 • DRAINAGE DETAIL — FINISH GRADE SLOPE AWAY FROM POOL 0 _..0 4 • GROUNDING & BONDING DETAIL 1 1 ' 1 J THREE-TIER RAISED SAFETY BARRIERS: 1 SH 4EER DECENT SCREEN ENCLOSURE AND WATER 1 a WATERFALL r TILE ON FRONT, ALARMS UP TO POOL SAFETY CODE. 1BACK s SIDESB-1 e� SEE DETAIL 1 -7" 1 1 GRADE 1 1 DIMENSIONS TAKEN FROM 1 1 1 EDGE OF WATER TO �1 PROPERTY LINE F 11 it 1 -1 1 _8" EL EVATI, 3IN OFFICE COY POOL BEAM 1 �I 1 UMBRELLA A c ANCHOR. E ............ i 1-- 22' 4"1 1 -6" ■ 1 � ; 1 GRADE ,,--HOSE BIB 1 1 1 1 PLUMBING LINE FROM POOL I---JCT BOX 1 1 1 MAIN DRAINS TO POOL POOL—� — EQUIPMENT 1 1 EQUIPMENT 1 1 1 ---------- AIC UNIT BARE #8 BOND WIRE ATTACHED TO POOL STEEL +s" THREE-TIER RAISED BEAM DECKING WITH 24" SHEER DECENT WATERFALL TILE ON FRONT, BACK & SIDES FRONT VIEW ADD 4" X 4" POST TO FORM PLUMBING LINE 24" FALLS" X 26" NOTCH FOR PAN \_ +12" 3' RR Q Z J O 00 O O N m O Y co V O CO N 0 LU N > 0o w .= M > Q w ui p Ili o Fw- m L) o w Z J w Z Z 3 w Z Z U Q O ZR 'w<3 v�a0 If RR Q Z J O 00 O O N m O JOB SPECIFIC PIPE SIZING, TOTAL DYNAMIC Ni CALCULATIONS AND EQUIPMENT SPECIFICATIO AND DOCUMENTATION ARE TO BE PROVIDED f POOL CONTRACTOR EOR EACW PROJECT. TWE CONTRACTOR-MU5T USE TWE MAXIMUM PLOW C, OF TWE SELECTED PUMP AND PROVIDE NYDRt CALCULATIONS FOR TDW TO DETERMINE PROP PUMP AND PIPING SIZING. TPE MANUFACTURER EQUIPMENT SPECIFICATIONS AND OTWER DOCU FOR PUMPS, FILTERS, NEATER EQUIPMENT AND DRAINS AND COVERS ARE TO BE SUBMITTED F REVIEW AND DOCUMENTATION FOR SIZING TWE CIRCULATION SYSTEM. RECIRCULATION PUMP CHLORINATOR POOL FILTER TWE SOL AC I TY .IC IN ATI ON 1-1/2 TIMES THE DIA. THE TWIN DRAIN PIPE INVERT NEEDS TO BE 13 TIMES THE DIAMETER DOWN FROM THE TOP OF THE MAIN DRAIN GRATE TO THE TOP OF THE MAIN DRAIN PIPE, IF THE PIPE COMES IN VERTICAL TO THE MAIN DRAIN BOX. IF THE MAIN DRAIN PIPE COMES INTO THE MAIN DRAIN BOX HORIZONTALLY, THE COVER FROM THE TOP OF THE GRATE TO TWE TOP OF TWE MAIN DRAIN PIPE NEEDS TO BE 15 TIMES THE DIA. OF TWE MAIN DRAIN PIPE. 1-1/2 TIMES THE DIA. MAIN DRAT IN DRAIN N RETURN LINE (OPTION WALL RETUR2 R __________________ WATER LINE DECK OVER POUR OR BRICK COPING 2-03 BARS--" N1-03 BAR CONT. CONT. IN 6" OF WATER IN 5" TWICK BOND S"XB' BOND LINE TILES BEAM BEAM UL APPROVED UNDERWATER LIGWT POOL &WELL 500o PSI Pu1P rnX COWAtETE `RETURN INLET 1r ------------ j II (OPTION WALL RETURNS) RETURNLRRE full Z II RETURN INLET MAIN DRAIN TION UNDERWATER LIGHT (OPTIONN �i MAIN DRAINS MEET Jj ==" I' I I 11 THE VIRGINIA GRAEME BAKER SKIMMER SUCTION POOL AND SPA SAFETY ACT. ii 'i i' in d �__—� -- — _ _ II _-----______====�r-===� L 12' ON C rye W }�y1�� V Uy� I F ee Z U. I i i FLOOR RETURN S.:LLI 111 p 3 REM -D. H W n VFW 1 RETURN _W W w = r CC RETURN INLET 1 I I SKIMMER � ! f.OPT WALL RETURNS) T I I 1 1 1 1 1 111 IMMER �W h RETURN LINE (OPTION WALL RETURNS! TYPICAL SWIMMING POOL LOW PROFILE 1,-6 =UNCTION VARIES BOX 4.0' SWIM MIN. OUT 6"X6• `M3 BARS GRADE 40,12" O.G. CERAMIC TILE VERTICAL AND ___ZJHORIZONTAL / (TYP) UL APPROVED UNDERWATER LIGWT POOL &WELL 500o PSI Pu1P rnX COWAtETE ° 1 fte"TICALLY APPLII!D. 6"-i" IN VERTICAL WALLS (TTP) B'-8' IN COVE5 AND FLOORS (TTP! 2500 MIN. GUNITE MAY BE SUBSITIUTED °lx FOR 3000 PSI CONCRETE FLOOR (KALL FORGEM 0 m t Z BREAK - n WU.4V 12' ON C 0<0Q WONC WATER LINE 1/2" QUARTZ FINISH -MAIN DRAIN W/ RELIEF PLUG OR 2 HYDROSTATIC RELIEF VALVE, IF READ. ROCKBED EACH WAY < 8.01 DEEP EACH WAY > 8A' DEEP AND OVER. 05 BARS 12' ON CENTER EACH WAY (GRADE 40) ALTERNATE BEAM FIN15W DETAIL J z a=.Jz avz_° 0 m t Z n WU.4V D 0<0Q Uy� F ee Z U. u. O W S.:LLI ¢W >. a _ m H W n VFW C _W W w CC PAVER DECKING OR 4" THICK CONCRETE DECK W/ FIBER MIX 2500 PSI OR WIRE MESH COMPACTED SOIL UNDER CONCRETE DECK NOT VALID WITHOUT EMBOSSED SEAL. a. a. * y5.,1tr ♦ n. �"` a .� E3: PARKER MYN I I1NBERG, i' Ei >�2645 GENERAL NOTES: 1. POOL 15 TO BE BUILT TO COMPLY WITH FLORIDA, COUNTY AND CITY BUILDING CODES. 2. ALL METAL PARTS WITHIN 5 FT. WILL BE GROUNDED AS PER NATIONAL ELECTRIC CODE AND AS REQUIRED BY LOCAL INSPECTOR. S. FILTRATION SYSTEM WILL HAVE SUFFICIENT CAPACITY TO PROVIDE A COMPLETE TURNOVER OF POOL WATER IN (12) TWELVE HOURS OR LESS. 4. POOL CONSTRUCTION TO BE TWE SAME REGARDLESS OF SIZE AND SHAPE, IF FILL IS REQUIRED FOR 2 FT. TO 4 FT. OF WALL HEIGHT THEN WALLS WAVE TO BE REINFORCED WITH ADDITIONAL STEEL (8" O.C. BOTW WAYS) AND/ OR EXTRA WALL THICKNESS (8' TO lo") S. ALL PVC PIPE WILL BE SCHEDULE 40. G. ALL METAL FIXTURES AND POOL LIGHTS TO BE BONDED TO POOL STEEL AND GROUND WIRE, T. POOL ALARMS DO NOT NEED TO BE HARDWIRED S. SOIL CONDITIONS AT POOL LOCATION ARE ASSUMED TO BE ADEQUATE FOR A SINGLE FAMILY DWELLING, 9. TERMITE CONTROL WILL BE APPLIED UNDER ALL POOL DEC". 10. ALL PUMPS AND FILTERS WILL BE ANCHORED TO A CONCRETE PAD WITH TAP CON ANCHORS. It. ALL POOL AND SPA SUCTION INLETS SHALL BR PROVIDED WITH A COVER THAT WAS BEEN TESTED AND ACCEPTED BY A RECOGNIZED TESTING FACILITY AND COMPLY WITW A.NS.IIA.SM.E. A112.19, 8M, "SUCTION FITTINGS FOR USE IN SWIMMING POOLS, SPAS, HOT TUBS, AND WHIRLPOOLS BATHTUB APPLIANCES" 12. THE POOL DESIGN WILL MEET GWAPTERS 42 AND 45 OF THE 2011 FLORIDA BUILDING CODE 6TH EDITION. 13. RESIDENTIAL POOLS MUST COMPLY WITH CHAPTERS 42 AND 45 OF TWE 20P1 FLORIDA BUILDING CODE 6TH EDITION. W. POOL CONSTRUCTION WILL MEET 2014 NATIONAL ELECTRIC CODE, SEE 680.26 (B)(2)(b) FOR PERIMETER BONDING DING AT LEAST OWED #8 AWG BARE SOLID COPPER CONDUCTOR. 15, FOR RESIDENTIAL POOLS UP TO A WATER DEPTH OF 8'-0" M3 REBAR 12" O.G.B,W, OVER 8'-0-; SPECIAL ENGINEERING IS REQUIRED AND 15 NOT A PART OF THIS DRAWING SPECIFICATIONS. WALL THICKNESS SHALL PROVIDE CODE COVER OVER REINFORCING. FOR OVER 8'-0" A SPECIAL DESIGN WILL BE REQUIRED. 16. RESIDENTIAL POOLS SHALL COMPLY WITH THE ANSI/APSPACC-5 2011 FOR RESIDENTIAL INGROUND POOLS, ANSI/APSP/I00-3 2014 FOR PERMANENTLY INSTALLED RESIDENTIAL SPAS, AND ANSI/APSP/ICC-'1 2013 FOR SUCTION ENTRAPMENT AVOIDANCE STANDARDS. AND AN5I/APSP/ICC-I5A 2013 STANDARD FOR RESIDENTIAL SWIMMING POOL AND SPA ENERGY EFFICIENCY 11- DO NOT USE OR OPERATE POOL OR SPA IF THE SUCTION FITTING 15 MISSING, BROKEN, OR LOOSE. 18- IF TWE SUCTION INLET SYSTEM, SUOW AS AN AUTOMATIC CLEANING SYSTEM, IS A VACUUM GLEANER SYSTEM WHICH WAS A SINGLE SUCTION INLET, OR MULTIPLE SUCTIONS INLETS WHICH CAN BE ISOLATED BY VALVES, TWEN EACH SUCTION INLET SHALL PROTECT AGAINST USER ENTRAPMENT BY EITHER AN APPROVED ANTI -VORTEX COVER, 12" X 12" GRATE OR LARGER, OR OTHER APPROVED MEANS. PARKER MYNOWENBERG 4 A550C. INC PROFESSIONAL ENGINEERS LANDSCAPE ARCHITECTS 1`129 RIDGEWOOD AVENUE HOLLY WILL FLORIDA 32111 (386) 611-6891 FAX (386) 611-2114 TYPICAL RE5IDENTAL 5WMOOL DE -516N FOR 5URP51 DE POOL5 313 BEACH BOULEVARD JACKSONVILLE BEACH, FL. 32250 (904) 246-2666 STATE LICENSE CPC044080 THIS SIGNED AND SEALED SHEET IS TO BE USED AS A MASTER FILE COPY . IT WILL BE USED FOR A MAXIMUM PERIOD OF ONE YEAR EXPIRING ON 12/31/18. IF THE FLORIDA BUILDING CODE 15 ALTERED OR MODIFIED BEFORE THAT DATE, THIS DRAWING MAY BE RENDERED VOID. SHEET 1 OF 5 RECIRCULATION CHLORINATOR POOL FILTER THE MAIN DRAIN THE DIAMETER L THERAPY JET MAIN DRAIN GR) MAIN DRAIN PIP TO THE MAIN DR RETURN LIFE ---_-� IF THE RAIN DRQ MAIN DRAIN BO; FROM THE TOP it ii MAIN DRAINS MEET THE VIRGINIA GRAEME SPA SAFETY ACT. OF THE MAIN OF TIMES THE DIA. BAKER P0a- p,WD MAY BE ON SIDE WALU j (SECOND MAIN DRAIN 14/2 TIM pal it MAIN DRAIN (SUCTION -- ---------Z ------------------- � dt� I1 I �I MAIN pRAIN UNDERWATER LIGHT 11 it n it I1 RETURN LINE '_---- I` ------------- ------ _---------- 11 __-===ii - 11 1-------- li 3/4" BULLNOSE I1 TILE OPTIONAL J GA Kbn ---------- ON EDGE OF STEP. MAIN opAlN5 ON FLOOR 2G-0T51TIRt UF-5OU0` TYPICAL 5PA 1=0 L - 2 PAVER DECKING OR CONCRETE POOL P51 GONG R L 3000 -IA GTI LY APPLIED. 4" THICK CONCRETE PECK STEEL "81 p) 6" IN VERTICAL WALLS -FIBERMIX 6" IN COVES AND LOT WATER 6 2500 MIN. GUNITE MAY BE 5UBSITIUTED LINE FOR 3000 MI CONCRETE 6"X6" CERAI'iIG TILE V2" pUARTZ FINISH /1-014 OFILE NVIION pEGK AND TILE Di VARIES BOX (L APPROVED 4.0 MIN. UNDERWATER LIGHT f I O COI pAGTED SOIL L 5 I I jITE IpUT NT0VALID (- UNDER CONGETE lil DECK EXTRA 113 BARS MAIN DRAIN CONTINUOUS tt�=ttt' 1'�ctsva" - SUCTION LINE ----- --------- - ___-- - . -____----- o +5 BARS 12" O.G. VERTICAL AND i!ae°.° .' • : •. < } f • F a00 Opo00 oC7 00 HORIZONTAL (TYP) (GRADE 40) a°e} et t o'pop0 Oo 2 MAIN ORA W/ RELIEF 000 000bo0PLW .1 ° t l .• 0 " = OR 2- µYDROSTATIG RELIEF 0000 0000 O 0 O 0.00 o Oo lrs y VALVE. IF REQ'D. oo r, ROGKBED .r(a�° i --1 PARKER MYNGNEI`46ERG, POOL BONDING NOTE5; I. EQUIPOTENTIL BONDING OF PERIMETER SURFACES COPPER CONDUCTOR; MINIMUM 08 AWG BARE SOLID CONDUCTOR WHICH FOLLOWS THE CONTOUR OF THE SURFACE OF THE POOL FROM 18" TO 24" FROM THE I OF THE POOL AND WHICH IS SECURED WITHIN OR UNI PERIMETER SURFACE 4" TO 6" BELOW 5UBGRADE. TI- BONDING SHALL BE ATTACHED TO THE POOL REINR AT A MINIMUM OF 4 POINTS UNIFORMLY SPACED ARO PERIMETER OF THE POOL. 2. ALL UNDERGROUND OR UNDER SLAB CONNECTIONS PER NEC 250.8. BONDING CABLES UNDER SLAB 5I4A OF EXCAVATION. 3. WHEN REBAR 15 UTILIZED FOR THE CONSTRUCTION C ADJACENT TO THE POOL (WITHIN 5 FT), THIS REBAR #8 AWG BARE SOLID COPPER CONDUCTOR BY LISTS TO THE BONDING CONDUCTOR. 4. LOCATION OF COPPER BONDING CONDUCTOR, BOND SHOWN ARE DIAGRAMMATIC ONLY. CONTRACTOR 514i EXACT LOCATION. BONDING CONDUCTOR SHALL C01% WHILE MAINTAINING SMOOTH RADIAL CURVES - NO 94 5. RESISTANCE OF THE GROUND SYSTEM SHALL NOT EX 6. IF REQUIRED, ALL GROUND RODS SHALL BE 5/8" GOP AND DRIVEN TO A DEPTH OF 28" BELOW FINISHED G USED SHALL BE BONDED USING M8 AWG BARE SOLID MEANS PER NEC 2508 TO THE BONDING CONDUCTOF 1. SPECIAL CASES MAY INCLUDE, BUT ARE NOT LIMITED POOL5 WITH PERIMETERS OF VARYING (VERTL) 6 SURFACES LIKE EDGE PLANTERS, STOP/RETAI I G Wo IN THESE CASES, THE BONDING CONDUCTOR SHALL E WITH NEC 680.26, NOTE I (ABOVE), AND DIRECTION F JURISDICTION (AHJ). THE ELECTRICAL CONTRACTOR COORDINATION OF THE BONDING WITH THE AHJ IN TI - APPLICATION OF THE NEC. LADDER, HANDRAIL, DIVING BOARD, ETC PUMP MOTOR METAL CONDUITS OR PIPING SYSTE POOL REINFORCING STEEL 0 HEATER TYPICAL POOL BONDING NOT TO SCALE O '— .... S. -COPPER BONDING CONDUCTOR 5HALL BE BONDED TO THE POOL AND SPA REBAR AS `QUIRES A SHOWN, 4 LOCATIONS, MINIMUM AT EACH SEPARATE BODY OF WATER, U51NG A k8 AWG GPPER BARE SOLID COPPER CONDUCTOR. FOR NON-CONDUCTIVE POOL SHELLS, BONDING ERIMETER AT 4 POINTS SHALL NOT BE REQUIRED. ., T WALLS :R THE q. COPPER BONDING CONDUCTOR SHALL BE BONDED TO THE EQUIF'I ANT GROUND OF PERIMETER THE POOL PUMP MOTOR AND OTHER ELECTRICAL COMPONENTS AS REQUIRED BY 'GING SHELL NEC 680,26 f VERIFY LOCATIONS) USING 08 AWG BARE SOLID COPPER WIRE. '— .... 10. COPPER BONDING CONDUCTOR 5WALL BE BONDED TO ALL METALLIC COMPONENTS OF THE POOL AND SPA AND THE METAL STRUCTURES, INCLUDING, BUT NOT LIMITED TO, ALL TALL BE BY LISTED MEANS THE AND ALL AND NG L BE PLACED AT THE BOTTOM UDE ALING L AETALRWIRING AND FIER XED METAL(N PARTS THAT ARE WITHIN FT. HORIZONTALLY OF THE INSIDE WALL OF THE POOL (SPA) AND 12 FT VERTICALLY ABOV PLANTERS AND FOOTERS THE MAXIMUM WATER LEVEL OF THE POOL USING #8 AWG BARE COPPER WIRE. 1LL BE BONDED USING 11. ALL POOL AND SPA LIGHTING NICHES SHALL BE BONDED TO POOL AND SPA REBAR MEANS PER NEC 250.8 PER NEC, 680. THE COPPER BONDING CONDUCTOR SHALL BE BONDED TO THE REBAR AT BOTH THE POOL AND THE SPA, PER NOTE 8, ABOVE, WHICH SHALL, IN G JUMPERS, AND CONNECTIONS TURN, PROVIDE BONDING OF THE LUMINAIRE NICHE5. L FIELD ROUTE TO DETERMINE 12 ELECTRICAL CONTRACTOR SHALL GALL FOR THE INSPECTION OF THE BONDING OF SRM TO THE SHAPE OF THE POOL RADIUS SHALL BE PERMITTED. THE POOL AND ITS PERIMETER SURFACES PRIOR TO COVER-UP OF THESE AREAS. ED 25 OHMS, c ER CLAD STEEL, S' LONG T 40E, MINIMAND WHERE NOTE iUM, / \ PPER CONDUCTOR BY LISTED C"TFICE COPY VANISHING EDGE POOL_5 NOTES 2 AND 3N 4. (SPA NOTE I 'OR OTI THE AUTHORITY HAVINGaNOTE 3 BOND JUMPER MINIMUM 5/8" DIAMETER LL BE RESPONSIBLE FOR NOTE 8 FROM POOL REBAR OR COPPER GROUND ROD DETERMINATION OF ITErYPICAL TYPICAL DRIVEN UNTIL MAXIMUM BONDING CONDUCTOR RESISTANCE VALUE OF NOTE q JUMPER 25 u p) 15 REACHED NOTE I TYPICAL BOND JUMPER NOTE 10 TYPICAL ° TYPICAL BONDING TYPE -5 SWIMMING POOL LT FIXTURE NOTES I, 4, NOTE 11 NOT TO 50LE r\ ° TYPICAL 5 AND 8 NOTE5, I. SPLICES (WELDED OR MECHANICAL) 5HALL BE PERFORMED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. FORMER TYPICAL POOL BONDING PLAN NOT TO SCALE JUNCTION BOX (IF USED) POOL LIGHT NICHE CONTROL PANEL(S) TIC SCHEMATIC NOTES, I. THE EQUIPOTENTIAL BONDING OF ALL CONDUCTIVE P 5HELL5, PERIMETER SURFACES, METALLIC COMPONENTS, UNDERWATER LIGHTING, METAL ITTINGS, ELECTRICAL EQUIPMENT, AND METAL WIREWAYS/CONDUITS SHALL BE IN ACCORD) NCE WITH NEC 680.26. OR, AS ACCEPTED BY THE AUTHORITY HAVING JURISDICTION IAWJ)_ BONDING LEGEND • BOND CONNECTION, PER NEC 2508 o PARALLEL TAP CONNECTION, PER NEC 2508 UNDERGROUND BONDING CONDUCTOR, 08 AWG (MINIM UMY w'Ti i ad 0 PARKER MYNCHEN51 RG& ARKER MYNOWENBERG 4 A550C. INC PROFESSIONAL ENGINEERS LANDSCAPE ARCHITECTS 1'729 RIDGEWOOD AVENUE HOLLY WILL FLORIDA 32111 (386) 611-6881 FAX (386) 611-2114 KOUT .: TYPICAL RE5IDENTAL 5W/POOL DE51GN FOR 5URF51DE POOLS 40 "q 313 BEACH BOULEVARD I ° y JACKSONVILLE BEACH, FL. 32250 + (gO4) 246-2666 i STATE LICENSE CPC044080 THIS SIGNED AND SEALED SHEET IS TO BE USED AS A MASTER F= FILE COPY , 1T WILL BE USED FOR A MAXIMUM PERIOD OF ONE Q' YEAR EXPIRING ON 12/31118. IF THE FLORIDA BUILDING CODE 15 ALTERED OR MODIFIED BEFORE THAT DATE, THIS DRAWING E ' . MAY BE RENDERED VOID. 26 5 SHEET 3 OF 5 4" DECK 05 BAR AT 12" ON CENTER BAR TO BE 5 FT LONG TURN DOWN FOOTER DETAIL BRICK PAVER POOL DECK Q� I-�3 BAR VERTICALLY jI n O 36" ON CENTER r �PIN I 1-463 BAR 8x1/2" X A CONTINUOUS Q" PAVER DECK TURNDOWN DETAIL 04 BAR AT 12' ON CENTER ®E 3-1/2" TYP ALL SLA55 03 REBAR CONT. I FT IN TO I FT IN MOTERATE SLOPE FOOTING TYPE 2 04 BAR AT M2" ON CENTER BAR AT 12" ON CENTER 04 BAR AT 12" ON CENTER 4 FT RETAINING WALL IMTAININS "A. WOO Ml PUMP rjX CotrREM I 1 BAR AT 12" ON CENTER 03 REBAR CONT. IFTIN6 OR STEEPER 5TIEPTYPE 2 OPE FOOTING SLAB -FOOTING DETAILS 2500 MIN. GUNITE MAY BE SUBSITIUTED FOR 9000 P51 CONCRETE USE 6X6 10/10 WW1 OR FIBER MESH CURE FOR ONE WEEK BEFORE INSTALLING ANCHOR5. THE FOOL CONTRACTOR SHALL PLACE ALL STEEL IN THE POOL WALL AT NO MORE THAN 6" ON CENTER IN BOTH DIRECTIONS IN AREAS WHERE THE ANGLE OF REPOSE IN ENCROACHED ON OR THE POOL WELL ENCROACHES INTO THE I TO I AREA. EXISTING STRUCTURE CONCRETE PAVER DECK 2" X 4' STRINGERS PLACED AT 2 FT ON F CENTER IN ALL AREAS STEEL TIX FORM W/ e0 STRUCTURAL STEEL IN PLACE TO BE INDEPENDENTLY SUPPORTED AWAY FROM SHORING. 12" 3000 PSI CONCRETE W/ 2-M3 RESAR5 THE POOL WELL WALL SHALL BE RIBBON AT 6" THICKNESS. FOOTING* • 3 REBARS AT G" ON CENTER W/ PAVER DECK BOTH WAYS IN AREAS TWAT EXTEND INTO THE ANGLE OF REPOSE +4 BAR AT 12" ON CENTER 5TRINGER MAY BE DRIVEN INTO GROUND MIN. q" OR OTHERWISE SUPPORTED TO PREVENT FROM KICKING OUT AT BASE. 5NORING DETAIL IN LOCATIONS WHERE EXISTING FOUNDATION 15 THREATENED SY UNDERMINING DUE TO ADVERSE CONDITIONS AT THE TIME OF EXCAVATION SHORING MAY BE REQUIRED. CONCRETE PAVER DECK 12" I 3000 PSI CONCRETE W/ 2-+3 REBARS RIBBON FOOTING W/ PAVER DECK SIDE WALLS NOT'�LID WITHOUT EMB /v rsj ED SEAL. CONCRETE PAVER DECK 12- 3000 PSI CONCRETE W/ 2-03 REBARS RIBBON FOOTING W/ PAVER DECK FEB 0 6 2016 FRONT WALL it-TICE COPY 3'-6" MIN. DISTANCE LE55 THAN 1 ON 1 STRINGER TO BE SUPPORTED BY CLEATIN6 TO SUITABLE ANCHOR DEVICE SUCH AS A 2" X 4' ATTACHED WITH ANCHOR NAILS OR TAPGONS TO EXISTING CONCRETE LANAI OR EXISTING STRUCTURE OR ITS FOUNDATION. EXISTING STRUCTURE -USE 1/2" PLYWOOD SWEETING OR EQUIVALENT BUILDING MATERIAL TO RESTRAIN SIDE OF EXCAVATION BACKFILL BEHIND SHORING TO PREVENT UNDERMINING OF EXISTING STRUCTURE. PROVIDE WEEP HOLES AS APPROPRIATE. CONTRACTOR SHOULD ATTEMPT TO CONSTRUCT ROUGH SHELL AS RAPIDLY AS CONDITIONS WILL ALLOW. THERE 15 NO SUBSTITUTE FOR RAPIDLY BACKFILLING EXCAVATION TO PREVENT UNDERMINING OF ADJACENT STRUCTURE. ARKER MYNCI-IENBERS 4 A550C. INC PROFESSIONAL ENGINEERS LANDSCAPE ARCWITECT5 1121 RIDGEWOOD AVENUE HOLLY WILL FLORIDA 32111 (386) 611-6811 FAX (386) 611-2114 TYPICAL izi=-51DENTAL 5W/PO0L DE51 GN FOR 5U%F51DE POOLS 313 BEACH BOULEVARD JACKSONVILLE BEACW, FL. 32250 (1O4) 246-2666 STATE LICENSE CPCO44080 THIS SIGNED AND SEALED SWEET 15 TO BE USED AS A MASTER FILE COPY. IT WILL BE USED FOR A MAXIMUM PERIOD OF ONE YEAR EXPIRING ON 12/31/18. IF TWE FLORIDA BUILDING CODE IS ALTERED OR MODIFIED BEFORE TWAT DATE, TWIS DRAWING MAY BE RENDERED VOID. PARKER MYNCWENBERG, P.E. «32645 11 SWEET 4 OF 5 MUD SET � u03 BAR AT 12* ON CENTER 04 BAR CONTINIOUS C�C �lil Ilil� -..L SWELL_ STANDARD YARD ELEVATION ��/i��ii~Ji��G��✓�✓i��/��i1�G�✓ice✓i � � � �'��1'���,. ��i����1�1�1j/Oj/t��/lam �`j0� `/ ✓ /11��,//'�1i/�j/O��1�1✓ G1✓ O/•000• .ine l ALUMINIUM SCREED 0ORI611T N5 BAR CONTINIOUS 8" X• Q Q CI _1 t' h 05 BAR AT 40" CENTER WITH CELL FILL WITH CONCRETE DECK DRAIN : ARCD YARD n / 4" FOOL DECK 4 X05 BAR AT �2' ON CENTER BLOCK WALL DETAIL WALL 3000 P51 PUMP MX CONCRETE ALUMINIUM SCREEN UPRIGHT 05 BAR AT 40" ON CENTER WITH CELL FILLED WITH CONCRETE DECK DRAIN i 4" POOL DECK BAR AT 12" ON CENTER BLOCK WALL DETAIL WALL 9000 P91 FU9P MX CONCRETE 6 FT RETAINING WALL RETAINING WALL 9000 Ml FU•P MX CONCRETE ITER , ° �{`''•II'cr''�y77'''�( `,A{<<((j�[((•''�� 311iiiii''pppnp. PARKER MYNCI' NBERxi PSE. *t%45 IBOSNDD BREAM WITH MAX SPACING IF UNDER 6'-0" 05 REBAR 12" MAx SPACING USE 04 REBAR IF UNDER 6'-0" • u B RETAINING WALL H A 5 C DOlIE S TOP FOOTING (O.CJ (O,C) 1'-4" 10" i'-8" 10" 05 48" 05 40" 2'-8" b" 1'-8' 10' 05 48" 05 40" 3'-4" 12" 2'-0" D" 05 48" 05 40- 4- Y2' 2'-0" 12` 05 48" 05 40- -S. 12" 2'-6" 12' 015 48" 05 40" 5'-4" 12" 3'-0" 12` +5 48" w5 40" 6' 1 12' 1 3'-8" 12" 05 48-1 05 40" TYP. RETAINING WALL DIMEN51ON5 PARKER MYNC14ENBERG 4 A550C. INC PROFE55IONAL ENGINEERS LANDSCAPE ARCHITECTS 1129 RIDGEWOOD AVENUE HOLLY WILL FLORIDA 32111 (386) 611-6891 FAX (386) 611-2114 TYPICAL RE -51 DENTAL SWMOOL DESIGN FOR SURFSIDE POOL5 313 BEACH BOULEVARD JACKSONVILLE BEACH, FL. 32250 (104) 246-2666 STATE LICENSE CPCO44080 THIS SIGNED AND SEALED SWEET 15 TO BE USED AS A MASTER FILE COPY. IT WILL BE USED FOR A MAXIMUM PERIOD OF ONE YEAR EXPIRING ON 12/31/18. IF THE FLORIDA BUILDING CODE IS ALTERED OR MODIFIED BEFORE TWAT DATE, THIS DRAWING MAY BE RENDERED VOID. SHEET 5 OF 5 Determine Maximum System flow Rate: Swimming Pool Info: 398 3 ( Surface Area) (Shallow) Spa Info: N/A 0 0 ( Surface Area (Depth) Preferred Turnover Time in Hours Maxium Pool Flow Rate: 10250 (gallons) Spa Jets (#) NONE (# of jets) A&A Quik Clean System NONE NONE NONE (# of heads) Maximum Pool System Flow Rate: Determine Pipe Sizes: Pool/Spa: Branch piping to be: Trunk piping to be : Return piping to be Determine Simplfied TDH (POOL►: 6 (Hours) Total is to 5 to N/A (Deep) (Shat ) x 60 min. = 3 0 (tumover time minutes) lation Volume: 10250 gallons Volume: 0 gallons 10250 Total Volume divided by 360 29_gpm 2.34 24 = 53 gpm (turnover time in minutes) (flowrat pool) (feature flow rate) x 13 gpm per jet = 0 flow rate (jet flow) *Total all other loss 5.64 nic Head (TDH) x 0 gpm Cleaner Head 0 flow rate x 0 gpm Cleaner Head 0 flow rate x 0 gpm Cleaner Head 0 flow rate (head flow) 146 gpm 0 Total Floor Heads flow rate 53 s' Highest required flo rate between "Maximum Pool Flow 13.7 Rate" and "Spa Jets" and "Quick Clean System" 3" --13w inch to keep velocity 6 fps.Max.at : 136 gpm. Maximum System Flow Rate -377-gpm. 3 inch to keep velocity 8 fps.Max.at : �10fps.Max.at: Maximum System Flow Rate 2" inch to keep velocity 18.2 103 gpm. Maximum System Flow Rate Distance from nearest edge of pool to pump in feet = 35 Friction loss in suction pipe 2.5" @ 8 fps inch pipe per one foot Friction loss in return pipe 2" @ 10 fps inch pipe per one foot Length of suction pipe 35 x Ft. of head per one foot of pipe Length of pressure pipe 35 x Ft. of head per one foot of pipe Other Loss in TDH Main Drain Returns 3/4" Therapy Jet Floor System *Total Filter loss in TDH (1 Heater loss in TDH Pool Total D Pool Pump: Jandu F/oPro VS -FHP 1 ha 53 Gallons Per Minute 16 Total Pool Filter: Jandu CS150 Cartridge Heater: None Pool Main Drain: Nova 7-314"1 F�a Floor Installation @ 150 gpm r 117 gpm ( from pipe flow/friction loss chart) = 0.09 ft. of head # 2.34 2.34 1 3.30 3.30 1 0.00 27.72 0 0.00 19.65 0 5.64 0,00 (from heater data sheet) Filter loss in TDH (1 Heater loss in TDH Pool Total D Pool Pump: Jandu F/oPro VS -FHP 1 ha 53 Gallons Per Minute 16 Total Pool Filter: Jandu CS150 Cartridge Heater: None Pool Main Drain: Nova 7-314"1 F�a Floor Installation @ 150 gpm r 117 gpm ( from pipe flow/friction loss chart) = 0.09 103 gpm ( from pipe flow/frichon loss chart) = 0,16 0.09 = 3.15 TDH in piping 0.16 = 5.60 TDH in piping TDH in piping 8.75 ter data sheet) 1.65 ( from filter data sheet) heater data sheet) 0,00 (from heater data sheet) *Total all other loss 5.64 nic Head (TDH) 16 is Head (TDH) flow Design Heed LOU (ft heed) Jelwdy" cartridge Fowl C813erlea 3 Design Piessure 2 DrOP (psi) --- CS150 1 . CS200 - CS250 --- CS100 T 0 30 60 90 120 Flow RAO (gpm) Flow and Friction Loss_ Per Foot Schedule 40 PVC Pipe Velocty - Feet Per Second I Total Head in Feet Conversion Chart Inches Mercury (Vacuum Gauge) -4-F-6 $ 1012 14 16 0 2 18 0 0.0 2.3 1 4.5 6.8 3.0 11.3 13.6 1 15.8 18.1 20.3 62 gpm 1 2.3 4.6 1 6.8 9.1 11.4 13.6 15.9 18.1 20.4 22.7 146 gpm 2 4.6 6.9 9.1 11.4 13.7 15.9 18.2 20.4 22.7 25.0 392 gpm 3 6.9 9.2 11.5 13.7 16.0 18.2 20.5 22.8 25.0 27.3 4 9.2 11.5 13.8 16.0 18.3 20.5 22.8 25.1 27.3 29.6 5 11.6 13.8 16.1 18.3 1 20.6 22.9 25.1 27.4 29.6 31.9 6 13.9 16.1 18.4 20.6 1 22.9 25.2 27.4 29.7 31.9 34.2 7 16.2 18.4 20.7 23.0 25.2 27.5 1 29.7 1 32.0 34.3 36.5 8 18.5 20.7 23.0 25.3 27.5 29.8 32.0 1 34.3 36.6 38.8 9 20.8 23.1 25.3 27.6 29.8 32.1 34.4 1 36.6 38.9 41.1 10 23.1 25.4 27.6 29.9 32.1 34.4 36.7 1 38.9 41.2 43.4 11 25.4 27.7 29.9 32.2 34.5 36.7 39.0 41.2 43.5 45.8 12 27.7 30.0 32.2 34.5 36.8 39.0 41.3 43.5 45.8 48.1 13 30.0 32.3 34.6 36.8 39.1 41.3 43.6 45.9 48.1 50.4 14 32.3 34.6 36.9 39.1 41.4 43.6 45.9 48.2 50.4 52.7 1 S 34.7 36.9 39.2 41.4 43.7 46.0 48.2 50.5 52.1 55.0 037.0 37.0 39.2 41.5 43.7 46.0 48.3 50.5 S2.8 55.0 57.3 L 7 17 39.3 41.5 43.8 46.1 48.3 50.6 52.8 55.1 57.4 59.6 4/ 1$ 41.6 43.8 46.1 48.4 50.6 52.9 55.1 57.4 59.7 61.9 N 91 If 43.9 46.2 48.4 50.7 52.9 55.2 57.5 59.7 62.0 64.2 L 46.2 48.5 50.7 53.0 55.2 57.5 59.5 62.0 64.3 66.5 ami 48.5 50.8 53.0 55.3 57.6 59.8 62.1 64.3 66.6 68.9 22 50.8 53.1 55.3 57.6 59.9 62.1 64.4 66.6 68.9 71.2 d 23 53.1 55.4 57.7 59.9 62.2 64.4 66.7 69.0 71.2 73.5 24 55.4 57.7 60.0 62.2 64.5 66.7 69.0 71.3 73.5 75.8 $ 57.8 60.0 62.3 64.5 66.8 69.1 71.3 73.6 75.8 78.1 26 60.1 62.3 64.6 66.8 69.1 71.4 73.6 75.9 78.1 80.4 27 62.4 64.6 66.9 69.2 71.4 73.7 75.9 78.2 80.5 82.7 28 64.7 66.9 69.2 71.5 1 73.7 76.0 78.2 80.5 82.8 85.0 29 6T.0 69.3 71.5 73.8 1 76.0 78.3 80.6 82.8 85.1 87.3 30 69.3 71.6 I 73.8 76.1 1 78.3 80.6 82.9 85.1 87.4 89.6 31 71.6 73.9 1 76.1 78.4 80.7 82.9 85.2 87.4 89.7 92.0 32 73.9 76.2 78.4 80.7 83.0 85.2 87.5 89.7 92.0 94.3 33 %.2 T8.5 80.8 83.0 85.3 87.S 89.8 92.1 94.3 96.6 �3L5 78.5 80.8 83.1 85.3 87.6 89.8 92.1 94.4 96.6 98.9 80.9 83.1 85.4 87.6 89.9 92.2 94.4 96.7101.2 Design Heed LOU (ft heed) Jelwdy" cartridge Fowl C813erlea 3 Design Piessure 2 DrOP (psi) --- CS150 1 . CS200 - CS250 --- CS100 T 0 30 60 90 120 Flow RAO (gpm) Flow and Friction Loss_ Per Foot Schedule 40 PVC Pipe Velocty - Feet Per Second Pipe Sixe 6 fps 8 fps 10 fps 1' 16 gpm 0.14' 21 gpm 0.23' 26 gpm 0.35' : 1.5" 37 gpm _008' 50 gpm 0.14' ,. 62 gpm 0.21' 62 gpm 0.06' _ 82 gpm _ 0.10' 103 gpm 0.16, i 2.5" 88 gpm 0.05' 117 gpm 0.09' 146 gpm 0.13' 3- 138 gpm 0.04' 181 -gpm 0.07' 227 gpm 0.10 I 4- 234 gpmOA3' 313 gpm OF 392 gpm 0.07' 6" 534 gpm 112 gpm 1 0.03' _ Pools • Spas • Service David & Jennifer Lamolinara 1883 Atlantic Beach Blvd. IlAtlantic Beach 32233 II 8/13/201 AS 30 G C►YY11�1I11�y LOT 55 AS SHOWN ON PLAT OF ATLANTIC BEACH COUNTRY CLUB UNIT 2 IN PLAT HOOK 67, PAGES 132-137 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FL. C SCALE 0 15 30 ( IIS FEET) I inch — 30 fL REVISION: 09-10-2018 MCM DECK SIZE REDUCED DUE TO EASEMENT DIMENSION ADDED IMPERVIOUS CALCULATIONS UPDATED MEASUREMENTS ARE FROM POOL WATERLINE TO PROPERTY LINE SCALE 1/30" = 1' ERS: CE pm ;MS �� 57 r 2s.st' 48.00' c.► � to A �� Wr G ~! 0 DENOTES PR)POSEO WOOD 1 DENOTES PR )POSED CONCRETE ® DENOTES PR OSED PAVERS tp 11.47' 7.66' •�C yah v / • \ r 1 14.23' 5.00' 54 MPERVIOUS CALCULATIONS OTAL LOT AREA: 10,672 SQ FT OUSE: 2,115 SQ FT RIVEWAY/SW: 1,065 SQ FT OVERED PATIO: 585 SQ FT OOL/COPING/DECK:862 SQ FT OTAL: 3.759 SQ FT DENOTES CH MCAL TOILET i - DENOTES FU RE 4- TREE GULRAL NOTES - I. KAflriCS ARE BASED ON THE C[NtERUME OF ATLANTIC BEACH WnE AS BEFF4 S09'31'51'E. 2 CRARIAGE [tiVA110IS SHOWN HEBEOM ARE BASED ON HA%0 IMIL 3 ME LAOS SHom Hatcam ' aTHN nboo ZONE 'ir As oviietto an THE FLOOD oism iNCI RATE MAP (rj wK) cowuaA NmIM 120077. PANEL MOM OIOEn. DATED. JJNE 3. 2011. THE FlDDD WiEs S"Dm Cm THIS SITE PLAN ARE SCALED OFF of THE rr.M A r ftu. NMS AND At FOR REJEROMct ONLY. 11E rlJt LL PiratimpaN AHD OCU MEAT10h'S ON TNS Dft PWM ARE VALIO ONLY FOR DATES UP TO AND INCLLONO THE DATE Or THIS SIZE PLAN THEM MAY NAK BEEN SUBSIOuCNT ACwSONS 0101 TNS DATE THAT SIRE SAID INFORYAIXIOL OM0JM SHOULD BE MADE TO THE CCEN i W"I'H'S FLOOD PLANE MANAGEMENT REPOSITORY, OtaMfLfdit Oi IUC nORK Ottr of ATLANTIC MEACK s ROOD MAPS RfiSAOaCED EON ARI BASED ON NAVD I"& 5. NO LNDCACRCUAup rauNoA OR UTIUI[S a NO AWROvE ENTS. OTHER THAN TIOM 2#004 9�i LOCATED WIDER THE SCOPE or THIS SITE PLAN. 6 ADDIt1011S. DELETIONS AAD ANr ww11[N INFORMATION ADDED TO MIS MAP AND/CA At701t r5 MICHI 1TED AND IS NOT Aur"O1hZCD By THC SOeNG YETOR. 7. Us MAP IS IHTi?I'DED 10 TEE IeCTICO ATA SCALE OF 1'-30' 09 SMALLER, 6 ENTRIES a PA TOS OEACIID 5 CxtEhtOeMC e11TO THE BUILCING FESTRICTIOM LIMITS MUST REMAIN UNCOVERM R NOT ENCLOSED 9. UPLAND 11WrlAi AGJAC011, 1 w[AAMp. ARE TO IOIAIN NATURAL, KGCTATIvC. ANO urw751lOMED is DIMENSIONS AAE IN )TIT DEOMAL PANTS THEREOF. 11 INS Silt PLAN IS ONLY FOR THE LIMOS AS 00CII8E0 IT 15 Nor A CERTIFICATE OF nTLL ZowNC. EASEMEMM OR FREEDOM or ENCUMBRA"MS. 12. THIS SITE PLAN IFAS Nor 1N Dm TO paimEATE OR Dam ANY TETLANOS. EHNRavANtALLY SENSTM1E AREAS. MILDLAE HALIOATS CR JulesONChONAt S Or ANY FEDERAL, $tArL REOOHK an LOCAL AGENCY. BOAAO. ANO COH M#_ ICN OR OMR oNnrr AND ANY UABRItT RESLA.IIrta AErRoM R NOT THE RL9`aHSTRU(T OF T►I[ uH10cRLraRMd. 13 MACS A COMPARISON IS OE. MCASUM SICARNG3 NO DISTANCES ARE IDENTICAL MM F%Ar VALUES 14. TWaa Siff PLAN IS BASED ON WORMAIM AS PROMOED BY ME a" ti BvLDNO AND siRotoacHr AS 0011CIEO 14EREOM ARE PEAPCHEOC UAR TO INC PANCFI PHgpptFY LINES LNtESS onlDrgSE NOTED. ALL MALDMFG DES ARE 40M TO THE rOU DA0014. 16. PLEASE ItUt1t TO TIK PLAT OR AOOITIO/K fIEMS THAT MAY AFFECT THIS Let. 17. TNS 1s Nor A 801RDA It 41AV. 18. PUKIC. S1DEWAtXS OEA 3ED OKON AW BASED ON THE CMSfRuCTiM PLANS my ARE sHosN rpm INFORMATIONAL Kr**SES otAr AND ARE not To BE ) W+arM FOR CpM51WChON, FOR CORRECT tOCATIGN AFD/dl OWE7MStOrti ItFfER TO THE MOST t1NRtENT set o1' COh51RUC110M S 1HL]Ic IS A YAIaARM >x SLOPE ON ALL SIOCwNJL2 ALL 'mOC1aAtX AND MiwOTht .MALL. AT A MutMW. MEET taIRROET NAL COUNTY AND ADA STA`tOAROS CROSS SLOPES SMALL K No KOBE THAN 2i THE Pt71tOW or ME SIDEWALK TMOH TR S THROUGH M DM%C*Ar APRoH SHALL ALSD IEEE INS RCOLSPpItJHf. ALSO. PLEASE NOTE MAT utwtlEs (LETER BORES. vALICs. ET-) •,MALL NOT BE INSTALLED alks; TIME SDEItim 19 DRAINAGE SIRVCRMiIS DEPIC MAY VART M SIZE. REM t0 ENGINEERING PLANS FOR CORRCCF pNDr90N5, 20 A/C PADS MAST MANtAN 2 AMAT FROM ANY PROPERTY UNC AND CAN NOT ENCROACH NTO A (WA IAaE EASEMENT DUI t0 DAAINAtY PtI REVISION A REWSM SIE PLAN . NEW SITE PLAN (5/23/17) (DOM/DBG) PREPAIM FOR: 'RSIDE HOMES x X 0 at to ir .l 5' �d grim F)N15H FLOOR ELEvATON MUST BE 2e ABOVE GRADE X• FRONT 20FEET FROM FACE OF CAIIAM 10 8ACK OF RMT or NAY A+O 15 FEET FROM rRAL01No FAC[ OR PowN TO BAOt Or b6Hl or *Ar. [At1rf ccomm/Dookc-rltommac LOIS, no araCH THE NON-ADORM FRMT 0"BACx 0r AtOHT ft0Wr FARO sMINl TIE 10 FM FROM OMAO[ M MAlDs10 FACE 0 OF MAX. 500 BREAKDOWN CURVE TABLE CURVE RAMS AtC LEWIN 0110110 OMIECTCN CNGRO LENGTH OCLTA CI(P) 50.00 3760 N53415e•E 3672 431WC2' C2iP) 77000 11314 MIs9•'17-W 111.06 3er1r56• X• FRONT 20FEET FROM FACE OF CAIIAM 10 8ACK OF RMT or NAY A+O 15 FEET FROM rRAL01No FAC[ OR PowN TO BAOt Or b6Hl or *Ar. [At1rf ccomm/Dookc-rltommac LOIS, no araCH THE NON-ADORM FRMT 0"BACx 0r AtOHT ft0Wr FARO sMINl TIE 10 FM FROM OMAO[ M MAlDs10 FACE 0 OF MAX. 500 BREAKDOWN TOTAL LOT AMA -TO 10.826 Sp. Ft R CURB 40 So., Ft. GROSS 50D ARCA It. FOUNDATION SLAB 3.828 Sit Ft. 4EWAY 991 sq. Ft. LEAD WALK 85 Sq Ft SOEWAIX AREA 0 SQ. FL A/C PAD(S) Et GARAGE S RVICJE DOOR SLAB 0 Sq. FL wAIER/CONSERNATION 0 S4 FL D93' �T_5(N1JlBE.� 6.421go, Ft. CERTIFIED TO: RIVERSIDE HOMES IMPERVIOUS COVERAGE NPOTNOMS St. rL LOT - FL = 4.639 Sq, rL I IOA26 St. rl 1 42ATT BUILDING COVERAGE COVERED Sq ft. I LOT Sq. FIL 1 2 3.677 Sq. Ft. 1 10.826 Sq Ft. 131n " j " �'- -•�• -Er'.•" B"TR" TRAIL SiT.TRVEYINGo INC. r. Mewtl Dew e/ew w.�ieo NMeow '""Zn .a�iewi. awwe.r ^p,. LAND SURVEYORS — PLNNERS —LEWD DEVELOPIUM' CON$ULTAM'3 w - «... . .......K. 11X/1 COUNTY ROAD 315 SUITE NO. 106 poi -pa8,* `.... K :: : .MMMpe,q>tpM. 1 Cava �. FAx 184 a - MOM r. w tcAM NM--ai-aaN w CERTIFICATE OF AUMORT MON 0 t� i 1.MIM :»:°"-" COPYRIOM 0 8018 .'3�NOTATION: r.tAAINE . FLOOD zD 1 HEREBY CERTIFY. that this survey graphieauy represents The survey hereon -os mode without benefit of abstract or w/ ELEVA110K X (NIA) the recutts Of o Field Survey made under my responsibleandthe •S :.w..r direction oed ca *% with the tritest Stondwds of � �ve3ong no& DIer6Forli eat Uf14 r*Wdd DIRE rrrn;t m Nur r.aa r WoeUct !or Serve o5 Ti++9 more no Grtl6ontione raperdhp Nlormotlen pfd �' 12007) 0406H 8 -emesnoMs -mato I, ys Promulgated by the nori00 Stowe shown or not shown hereon pertaining 10 easements, dalms /3/13 Board of Prolessional Surveyar5 one M Chapter g Mapper-- 00 0( cosemHklts. R)ghla-e(-way. tethatk linlL, ev6Aaps, NA` SJ -17 F.A.C.: Pursuant to section 472427. Flaido E)oundory tine d Wtes. OWeentents, reservoNons or other Fe/POs N/A ie,,,rN„a,�,,,, „11 ctotuec, subject to all noted and notations shown hereon Similar matters which may appear in the abstract. or scorch. • pawn lar fMRw IwIwIMeMY PVI . wa MA w.e VIM wr AMM N/A N/A This curve i8 Mn -Fre Aur-. ur.M.rw a wnr—.e OATS SCALE Y ed hereon and Certified far the exclusive Fee use Of 10/ZO/18 1'=30' RELO tNORK C01fPtJ:TEO MAP 4RIGWAl1Y SIGNED the diem named h/rrOOn Ono the survey mop and r9port Of the copies thereof are not valid without the signature and N/A ere ari*ol raised seal of o Florida licensed surwyor and PROJE� NREMStONr A THOMAS P HUGHES. P.LS mapper• 1344-i6ti-03S STATE OF FLORIDA LICENSE, NUMBER LS 3507 r0RAwt BY: STH CHECKED BY: OOD SHEET 1 OF__L_