Loading...
1221 MAYPORT RD - INTERIOR BUILDOUT DRAWINGS (JAGUAR POWER)IC L 1 SYMBOLS LEGEND STANDARD DRAWING TITLE SCALE: */*1, _ *1_*11 SECTION OR DETAIL X IDENTIFICATION NUMBER VIEW X SECTION PLATE NUMBER ON WHICH SECTION OR DETAIL IS DRAWN SECTION / DETAIL SYMBOL EL: 01-011 B A IDENTIFICATION ELEVATION TARGET pXez" LETTER WHERE X. ELEVATION IS TAKEN xxx C LINE 1 LINE 2 ELEVATION SYMBOL AREA SYMB L 1 2 TE JA(:3 I ANT IMPROVEMENTS FOR AR POVVER P S ORTS 1221 MAYPORT RD ATLANTIC BEACH, FLORID APPLICABLE GEODES - 2017 FLORIDA BUILDING CODE: 6th EE ITION: BUILDING - 2017 FLORIDA BUILDING CODE: 6th EITION: EXISTING BUILDING - 2017 FLORIDA BUILDING CODE: 6th EDITION: MECHANICAL - 2017 FLORIDA BUILDING CODE: 6th E ITION: PLUMBING - NFPA 70 - 2014 NATIONAL ELECTRICA CODE - 2017 FLORIDA FIRE PREVENTION CO E: 6th EDITION BASED OFF NFPA 1 AND NFPA 101 201 EDITION VICINITY MAP 2 NOT TO SCALE 3 Sn �� tvv A 32233 PROJECT NARRATIVE PROJECT CONSISTS OF THE TENANT IMPROVEMENTS OF AN APPROXIMATELY 2,507 SF EXISTING SPACE. THE EXISTING SPACE IS FOR MERCANTILE PURPOSES. NEW PLUMBING AND, ELECTRICAL COMPONENTS WILL BE INSTALLED BY A LICENSED CONTRACTOR. AN EXISTING MECHANICAL SYSTEM IS IN PLACE AND FUNCTIONAL AND WILL BE MODIFIED TO ACCOMMODATE THE NEW FLOOR PLAN. KEY PLAN NOT TO SCALE 5 It STANDARD ABBREVIATION ~ co � 00 N ALUM ALUMINUM FL FLOOR W = o0oI ARCH ARCHITECTURAL FT FOOT, FEET ACT ACOUSTIC CEILING TILE GL GLASS CD Q O BD BOARD GB GYPSUM WALL BOARD CIO BLDG BUILDING HT HEIGHT ■ CLG CEILING HR HOUR COL COLUMN HW HARDWARE CONIC CONCRETE INT INTERIOR CONST CONSTRUCTION JT JOINT CPT CARPET LB POUNDS CT CERAMIC TILE MAINT MAINTENANCE A DTL DETAIL MAX MAXIMUM DIA DIAMETER MECH MECHANICAL DIM DIMENSION MTL METAL DN DOWN MIN MINIMUM DWG DRAWING MISC MISCELLANEOUS EA EACH MS MARBLE SADDLE EL ELEVATION N/A NOT APPLICABLE EQUIP EQUIPMENT NIC NOT IN CONTRACT EXIST EXISTING NO NUMBER FD FLOOR DRAIN OC ON CENTER FIN FINISH WD WOOD 1 2 TE JA(:3 I ANT IMPROVEMENTS FOR AR POVVER P S ORTS 1221 MAYPORT RD ATLANTIC BEACH, FLORID APPLICABLE GEODES - 2017 FLORIDA BUILDING CODE: 6th EE ITION: BUILDING - 2017 FLORIDA BUILDING CODE: 6th EITION: EXISTING BUILDING - 2017 FLORIDA BUILDING CODE: 6th EDITION: MECHANICAL - 2017 FLORIDA BUILDING CODE: 6th E ITION: PLUMBING - NFPA 70 - 2014 NATIONAL ELECTRICA CODE - 2017 FLORIDA FIRE PREVENTION CO E: 6th EDITION BASED OFF NFPA 1 AND NFPA 101 201 EDITION VICINITY MAP 2 NOT TO SCALE 3 Sn �� tvv A 32233 PROJECT NARRATIVE PROJECT CONSISTS OF THE TENANT IMPROVEMENTS OF AN APPROXIMATELY 2,507 SF EXISTING SPACE. THE EXISTING SPACE IS FOR MERCANTILE PURPOSES. NEW PLUMBING AND, ELECTRICAL COMPONENTS WILL BE INSTALLED BY A LICENSED CONTRACTOR. AN EXISTING MECHANICAL SYSTEM IS IN PLACE AND FUNCTIONAL AND WILL BE MODIFIED TO ACCOMMODATE THE NEW FLOOR PLAN. KEY PLAN NOT TO SCALE 5 It SHEET INDEX ARCHITECTURAL G1.0 COVER SHEET / PROJECT INFORMATION A1.0 LIFE SAFETY PLAN / CODE SUMMARY / DETAILS Al. 1 FLOOR PLAN / WALL TYPES A1.2 REFLECTED CEILING PLAN M1.0 MECHANICAL PLAN / CALCS P1.0 PLUMBING PLANS / RISERS E1.0 LIGHTING PLAN E1.1 POWER PLAN / PANEL SCHEDULE / LOAD CALCS / RISER CODE COMPLIANCE REVIEWED FOR ATLANTIC BEAG�1 CITY OF AT SEE PERMITS FOR ADDITIONAL NS REQUIREMENTS AND rCO 8Y= REVIEWED 'DATE: RI ICIKICCC nl' fr l IDA KIT ELECTRICAL DISCONNECT 2] -SITE LIGHTING & t'HKKINU SITE LIGHTING 21 MAYPORT RD .JASON CANNING ARCHITECT INC ARCHITECTURE PLANNING INTERIORS 1812 Atlantic Blvd. Jacksonville, Florida 32207 O: 904.647.8690 C: 904.755.5589 F: 904.406.7227 jasonga canningarch.com D ( PROJECT ARCHITECT IC 110011 JASON T. CANNING t� FLORIDA LICENSE NO. AR95310 PROJECT TEAM OWNER SHAWN JACKREL ARCHITECT JASON T. CANNING 904.647.8690 [DATE ISSUE 24 SEPT 2018 PERMIT Wz JI O SHEET INDEX ARCHITECTURAL G1.0 COVER SHEET / PROJECT INFORMATION A1.0 LIFE SAFETY PLAN / CODE SUMMARY / DETAILS Al. 1 FLOOR PLAN / WALL TYPES A1.2 REFLECTED CEILING PLAN M1.0 MECHANICAL PLAN / CALCS P1.0 PLUMBING PLANS / RISERS E1.0 LIGHTING PLAN E1.1 POWER PLAN / PANEL SCHEDULE / LOAD CALCS / RISER CODE COMPLIANCE REVIEWED FOR ATLANTIC BEAG�1 CITY OF AT SEE PERMITS FOR ADDITIONAL NS REQUIREMENTS AND rCO 8Y= REVIEWED 'DATE: RI ICIKICCC nl' fr l IDA KIT ELECTRICAL DISCONNECT 2] -SITE LIGHTING & t'HKKINU SITE LIGHTING 21 MAYPORT RD .JASON CANNING ARCHITECT INC ARCHITECTURE PLANNING INTERIORS 1812 Atlantic Blvd. Jacksonville, Florida 32207 O: 904.647.8690 C: 904.755.5589 F: 904.406.7227 jasonga canningarch.com D ( PROJECT ARCHITECT IC 110011 JASON T. CANNING t� FLORIDA LICENSE NO. AR95310 PROJECT TEAM OWNER SHAWN JACKREL ARCHITECT JASON T. CANNING 904.647.8690 [DATE ISSUE 24 SEPT 2018 PERMIT Wz F- O ~ co � 00 N z N uj o (y)W F_ Q w LL :2 W0� W = o0oI Q w 11� l_ zo < mW> N= Q~ U— OW z<< CD Q O �c CIO PROJECT NO: 1877 DRAWN BY: DS CHECKED BY: JTC SHEET NO: ■ SHEET 1 x C 0 . ►0 1 APPROACH MINIMUM CLEARANCES 1. APPROACH REQUIREMENTS ARE FOR SWINGING DOORS ONLY 2. DIMENSIONS ARE MEASURED FROM FINISH SURF CES FRONT APPROACH NOTE; X=12" IF DOOR HRS BOTH A CLOSER AND A LATCH PULL SIDE PUSH SIDE I— z 18" MINI HINGE -SIDE APPROACH NOTE: X=36" MIN IF Y=60" NOTE: Y=48" MIN IF DOOR HAS BOTH X=42" MIN IF Y=54" A CLOSER AND A LAT(,*H PULL SIDE PUSH SID 54" MIN z >- N a LATCH -SIDE APPROACH NOTE: Y=54" MIN IF DOOR NOTE: Y=48" MIN IF DOOR HAS A CLOSER HAS A CLOSER PULL SIDE PUSH SIEJE I— [— — 7 - X z_ ��2 MAX. TRAVEL DISTANCE TO AN EXIT: 200 FT WITHOUT 24" a (TABLE 1016.1) 0 FEB MIN MOUNT AT 4' TO 5'A. F. F. boar 118`1 „CENTERED ON ' 18 ' TACTILE MIN. CHARACTERS TACTILE EXIT SIGN 1 2 CODE SUMMARY 1. USE AND OCCUPANCY CLASSIFICATION - (FBC-B: 309.1 & NFPA 101) GROUP M: MERCANTILE NO CHANGE OF USE 2. GENERAL BUILDING HEIGHTS AND AREAS - (FBC-B: Cl-APTER 5) GROSS BUILDING AREA: 2,507 SF EXISTING No. OF STORIES ALLOWED: 1 No. OF STORIES PROVIDED: 1 EXISTING BUILDIN MAX. SF ALLOWED: 9,000 SF EXISTING BUILDING BUILDING HEIGHT: EXISTING BUILDING; TENANT IMPROVEMENT ONLY No. UNITS PER FLOOR: N/A MEZZANINE: NO 3. TYPES OF CONSTRUCTION - (FBC-B: CHAPTER 6) TYPE VB - EXISTING (FBC-B: TABLE 601) NOWSPRINKL RED 4. ACCESSIBILITY-( FBC-B: CHAPTER 11) ADA COMPLIANT: YES 100% 5. INTERIOR FINISHES- (FBC-B: CHAPTER 8- TABLE 803.11) GROUP M: NON-SPRINKLERED EXIT PASSAGE: A FINISH CORRIDORS: B FINISH ROOMS ENCLOSED SPACE: C FINISH 6. MEANS OF EGRESS - (FBC-B: CHAPTER 10) TOTAL OCCUPANT LOAD = 36 (TABLE 1004.1.1) MERCANTILE: 2,044 SF @ 60 GROSS SF/PERSON = 34 ACCESSORY STORAGE: 250 SF @ 300 GROSS SFPERSON _ 1 BUSINESS AREA: 140 SF @100 GROSS SF/PERSO = 1 EGRESS WIDTH PER OCCUPANT SERVED: 0.2 PER OC dUPANT= 7" (SECTION 1005) SPACES WITH ONE MEANS OF EGRESS (TABLE 1015.1) MAX LOAD = 49 MAX. TRAVEL DISTANCE TO AN EXIT: 200 FT WITHOUT SPRINKLER SYSTEM (TABLE 1016.1) 0 FEB MIN. NUMBER OF EXITS: (SECTION 1021) = 1 7. AUTOMATIC SPRINKLER SYSTEMS - (FBC-B: CHAPTER - SECTION 903) NO EXISTING SPRINKLER SYSTEM IN PLACE 8. PLUMBING FIXTURE - (FBC-P: CHAPTER 4) VIDED (IN.) MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES. (FBC-P:TABLE 403.1 FIXTURES REQUIRED BASED ON TOTAL OCCUPA CY: 36 PERSONS WATER CLOSETS: 1:500 MALE / FEMALE = 1 M / 1 LAVATORIES: 1:750 MALE / FEMALE = 1 M / 1 F DRINKING FOUNTAIN: 1 HI -LO PROVIDED SERVICE SINK: 1 REQUIRED (1 PROVIDED) NOTE: 1. EXISTING ACCESSIBLE PARKING SPACES AND RAMP ARE IN 24" 04 PLACE. THE SIDEWALK IS FLUSH WITH THE FLOOR L VEL OF MIN THE INTERIOR SPACE AND THE THRESHOLD DOES N T EXCEED THE HEIGHT LIMIT. 2. PROVIDE LIGHT GAUGE METAL ROOF TRUSS TYPE S MBOL "R" FOR THIS BUILDING. LIFE SAFETY LEGEND • �' DESIGNATED EXIT EXIT SIGN 130' EXIT PATH AND TRAVEL DISTANCE CO 0 FEB FIRE EXTINGUISHER BRACKET 30 6” 36" NO. OF OCCUPANTS/ EXIT WIDTH Q REQ'D. (IN.)/ EXIT WIDTH PR VIDED (IN.) 5 2 HR. FIRE RATED PARTITIO 0W C� >w OOCCUPANCY LOAD 20<00 EMERGENCY LIGHT 4 D F- U Q N F- �<^ v! W 0 EXIT SIGN/ EMERGENCY COI BO E J w w cn J � <w W u) N I-�0� zmw QCL Z - ow~0 - QXj ww m J J W PROVIDE TACTILE EXIT DOOR SIGNAGE READING ,"EXIT" 4 I 5 Q.l 7___-I_J 1 LIFE SAFETY PLAN NORTH A1.0 SCALE: 1/4" = l'-0" PROVIDE LIGHT -FRAME TRUSS -TYPE SYMBOL "R" AT 4'MIN. TO 6' MAX. A.F.F. AND WITHIN 24" OF DOOR. SCALE: 1/4"=V-0" 0 2.5' 5' 10' VALL HUNG MIRROR PROVIDE INSULATION AT ALL EXPOSED PIPING FOR "ACCESSIBLE" OR HANDICAPPED LAVATORIES. PIPE INSULATION SHALL COMPLY WITH APPLICABLE REQ. OF THE AMERICAN W/DISABILITIES ACT (ADA). PAPER TOWEL DISPENSER LAVATORYle 24"MIN. 12"MIN. � 12"MAX. TOILET - HANDLE PAPER SKIRT CLOSURE THIS SIDE - HOLDER SIDE o z M `r 15„ M b M N cM 16"-18" SCALE: 1/2"=V-0" 3 EWC ELEVATIONS A1.0 SCALE: 1/2" = 1'-0" 0 1.5' 3' 5' NOTE:. WALLS WITHIN 2 FEET OF URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH HARD, NONABSORBENT SURFACE TO A HEIGHT OF 4 FEET ABOVE THE FLOOR, AND EXCEPT FOR STRUCTURAL ELEMENTS, THE MATERIALS USED IN SUCH WALLS SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE. (FBC-B 1210.2) 2 TYPICAL TOILET ELEVATIONS SCALE: 1/2"=1'-0" A1.0 SCALE: 1/2" = l'-0" 0 1.5' 3' 5' 5 C 0 0 c 0 U i to 0 cn cn E a CL PROJECT ARCHITECT 0) c JASON T. CANNING @E 4-+ 4- 4-j FLORIDA LICENSE N0.'AR95310Jc�_+ DATE ISSUE 24 SEPT 20181 PER W CO z Q� �- z� N W M J Q > w LL OO v ��J 5 u) 0W C� >w W ��C 20<00 ��W F- U Q N F- �<^ v! W 0 0 wQ�� W 0 Q JU 104 PROJECT: 1877 DRAWN BY: DS CHECKED BY: JTC SHEET NO: Al ■ SHEET 0 . m i E 0 -1-1 m E 0 4•- 0 U s.. 0 U 0 L L 0 0 m c m cm c CCi woo 0 4-j -� Jc .1 U) 0 cn v CL X N m U 0 FIRESAFE SEAL VOIDS TYP. 2-1/2" 25 GA.0-T STUDS @ 24" O.C. (2) LAYERS 5/8" GB (1) LAYER 1" GB J -TABBED TRACK — D EXISTING CONCRETE — TIE BEAM EXISTING 8" CMU 7/8" FURRING CHANNELS (1) LAYER 5/8" 1 R J D �r rn J 2 2 HR RATED, NON LOAD BEARING STUD WALL UL DESIGN No. U914/V415 PARTITION TYPE AI, _ , ,1 SCALE: 3/4 — 1 -0 SCALE: 3/4"=1'-0" 0 1' 2' 4, C 0 NEW ACT C =-ILING 2X4 WALL UD @ 16" O.C. 1 LAYER 5/ " G EACH SIDE 2X4 PT B TTOM PLATE NOWTED, NON LOAD BEARING STUD WALL PARTITION TYPE B _ 1 SCALE: 3/4.1 — 1 -0 SCALE: 3/4"=1'-0" 0 1' 2' 4, 1 1 ' 2 EXISTING MTL— DECK BRACE TO STRUCTURE AS REQUIRED 2X6 TOP PLATE -�--NEW 5/8" GB CEILING NEW ACT CEILING 1 LAYER 5/8" GWB EACH SIDE 2X6 WALL STUD @ 3 1/2" ACOUSTIC : BATT INSUL. 16° O.C. OPTIONAL _tom ti 2X4 PT BOTTOM %"e PLATE _z�� NON -RATED, NON LC AD BEARING STUD WALL PARTITION TYPE C SCALE: /4„ _ — 1 , -0„ SCALE: 3/4"=1'-0” 9 0 1' 2' 4' 20'-5” 101 STORAGE y o °o z > J � w o cn 1 EXISTING DOOR OPENING, CLOSE IN PER WALL TYPE A, UL # U415 o O O 4L�� i-- -0 i' a o 0 ABOVE DOOR SCHEDULE EXISTING WOOD ECK-J BRACE TO STRUC URE AS REQL IRED 2X4 T P PLATE 2 HR RATED, NON LOAD BEARING STUD WALL UL DESIGN No. U914/V415 PARTITION TYPE AI, _ , ,1 SCALE: 3/4 — 1 -0 SCALE: 3/4"=1'-0" 0 1' 2' 4, C 0 NEW ACT C =-ILING 2X4 WALL UD @ 16" O.C. 1 LAYER 5/ " G EACH SIDE 2X4 PT B TTOM PLATE NOWTED, NON LOAD BEARING STUD WALL PARTITION TYPE B _ 1 SCALE: 3/4.1 — 1 -0 SCALE: 3/4"=1'-0" 0 1' 2' 4, 1 1 ' 2 EXISTING MTL— DECK BRACE TO STRUCTURE AS REQUIRED 2X6 TOP PLATE -�--NEW 5/8" GB CEILING NEW ACT CEILING 1 LAYER 5/8" GWB EACH SIDE 2X6 WALL STUD @ 3 1/2" ACOUSTIC : BATT INSUL. 16° O.C. OPTIONAL _tom ti 2X4 PT BOTTOM %"e PLATE _z�� NON -RATED, NON LC AD BEARING STUD WALL PARTITION TYPE C SCALE: /4„ _ — 1 , -0„ SCALE: 3/4"=1'-0” 9 0 1' 2' 4' 20'-5” 101 STORAGE y o °o z > J � w o cn 1 EXISTING DOOR OPENING, CLOSE IN PER WALL TYPE A, UL # U415 o O O 4L�� i-- -0 i' a o 0 ABOVE NOTES: 1. PROVIDE THUMB TURN LO KS ON THE INTERIOR OF ALL EXTERIOR DOORS 2. PROVIDE LEVER TYPE DO �R KNOB WITH PUSH BUTTON PRIVACY LOCK AT ALL SINGLE USE RESTROOMS Cl 14'-3 3/4" 100 SHOWROOM 2'-11" i, 14'-7" ELEC i 10 D ce) 100B 4> 102 B OFFICE l Cti CO FLOOR P LAN SCALE: 1 /4"=1'-0" WALL LEGEND N RTH A1.1 NEW WALL SCALE: 1 /4" = 1'-0" 0 2.5' 5' 10' EXISTING WALL TYPICAL WINDOW ELEVATION / SCALE: 1/211 = 1'-0" SCALE: 1/2"=l' -O" 0 1.5' 3' 5' 4 GENERAL NOTES 5 EXISTING DOOR, CLOSE AND REMOVE HARDWARE 6-6" O 103 RR 1 �i MOP SINK 103 B \o/ \o/ 2 A1.1 EWC U) m z G) 1. ALL DESIGN, CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION OVER THE WORK. 2. DETAILS FOUND WITHIN THESE DRAWINGS SHALL BE ASSUMED TO BE TYPICAL DETAILS FOR THIS JOB ONLY. DETAILS SHALL GOVERN CONSTRUCTION FOR THIS JOB UNLESS NOTED OTHERWISE ON THE PLANS. 3. DIMENSIONS ARE TO FACE OF STRUCTURAL FRAMING, UNLESS OTHERWISE NOTED. 4. DO NOT SCALE DRAWINGS. WHERE NO DIMENSIONS, OR DISCREPANCIES OCCUR, VERIFY CORRECT LOCATION WITH ARCHITECT PRIOR TO ERECTION, FABRICATION OR INSTALLATION. 5. PROVIDE PROPER SEPARATION BETWEEN ALL DISSIMILAR MATERIALS. 6. GC REQUIRED TO PATCH AND REPAIR ALL EXISTING AREAS EFFECTED BY NEW WORK. FINISH, COLOR, TEXTURE TO MATCH EXISTING. 7. ARCHITECT IS NOT RESPONSIBLE FOR ANY UNFORSEEN CONDITIONS DISCOVERED ONCE DEMOLITION BEGINS. 8. THERE SHALL BE NO DEVIATIONS FROM ARCHITECTURAL DRAWINGS WITHOUT WRITTEN APPROVAL OF THE ARCHITECT. 9. BLOCKING IN PARTITIONS SHALL BE PROVIDED IN ALL AREAS WHERE REQUIRED, WHICH WILL INCLUDE, BUT IS NOT LIMITED TO, OPEN AND CLOSED SHELVING, COAT POLES AND SHELVES, CABINETRY, TENANT SUPPLIED WALL MOUNTED FURNITURE SYSTEMS, COUNTERS, GRAB BARS, FIXTURES OF ANY KIND, AND MOLDINGS/TRIM. 10. GC TO VERIFY ALL DIMENSIONS IN THE FIELD. 11. DIMENSIONS NOTED AS "CLEAR" SHALL BE FROM FINISHED FACE TO FINISHED FACE. 12. GC TO PROVIDE OWNER WITH ALLOWANCE FOR ALL NEW PLUMBING, MECHANICAL AND ELECTRICAL FIXTURES. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARATION OF EXISTING WALL SURFACES TO RECEIVE NEW FINISHES AS SCHEDULED. 5 JASON CANNING ARCHITECT INC ARCHITECTURE PLANNING INTERIORS 1812 Atlantic Blvd. Jacksonville, Florida 32207 O: 904.647.8690 C: 904.755.5589 F: 904.406.7227 j as on@canningarch. coin D DDn ICt'`T ADt-%UlTC/%T u 0 JASON T. CANNING FLORIDA LICENSE'NO. AR95310 PROJECT TEAM OWNER SHAWN JACKREL ARCHITECT JASON T. CANNING 904.647.8690 DATE ISSUE 24 SEPT 2018 PERMIT DOOR SCHEDULE DOOR NO. SIZE W TYPE MATERIAL REMARKS 100A 61X6'-8" — ALUM/GLASS EXISTING 100B 2'-0"X6'-8" BI -F LD — WOOD Z Q 101 61X6'-8" — WOOD 102 3'X6'-8" �JQ — WOOD 0�~ 103 3'X6'-8" __j 0pW — WOOD JW NOTES: 1. PROVIDE THUMB TURN LO KS ON THE INTERIOR OF ALL EXTERIOR DOORS 2. PROVIDE LEVER TYPE DO �R KNOB WITH PUSH BUTTON PRIVACY LOCK AT ALL SINGLE USE RESTROOMS Cl 14'-3 3/4" 100 SHOWROOM 2'-11" i, 14'-7" ELEC i 10 D ce) 100B 4> 102 B OFFICE l Cti CO FLOOR P LAN SCALE: 1 /4"=1'-0" WALL LEGEND N RTH A1.1 NEW WALL SCALE: 1 /4" = 1'-0" 0 2.5' 5' 10' EXISTING WALL TYPICAL WINDOW ELEVATION / SCALE: 1/211 = 1'-0" SCALE: 1/2"=l' -O" 0 1.5' 3' 5' 4 GENERAL NOTES 5 EXISTING DOOR, CLOSE AND REMOVE HARDWARE 6-6" O 103 RR 1 �i MOP SINK 103 B \o/ \o/ 2 A1.1 EWC U) m z G) 1. ALL DESIGN, CONSTRUCTION AND MATERIALS SHALL BE IN ACCORDANCE WITH APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION OVER THE WORK. 2. DETAILS FOUND WITHIN THESE DRAWINGS SHALL BE ASSUMED TO BE TYPICAL DETAILS FOR THIS JOB ONLY. DETAILS SHALL GOVERN CONSTRUCTION FOR THIS JOB UNLESS NOTED OTHERWISE ON THE PLANS. 3. DIMENSIONS ARE TO FACE OF STRUCTURAL FRAMING, UNLESS OTHERWISE NOTED. 4. DO NOT SCALE DRAWINGS. WHERE NO DIMENSIONS, OR DISCREPANCIES OCCUR, VERIFY CORRECT LOCATION WITH ARCHITECT PRIOR TO ERECTION, FABRICATION OR INSTALLATION. 5. PROVIDE PROPER SEPARATION BETWEEN ALL DISSIMILAR MATERIALS. 6. GC REQUIRED TO PATCH AND REPAIR ALL EXISTING AREAS EFFECTED BY NEW WORK. FINISH, COLOR, TEXTURE TO MATCH EXISTING. 7. ARCHITECT IS NOT RESPONSIBLE FOR ANY UNFORSEEN CONDITIONS DISCOVERED ONCE DEMOLITION BEGINS. 8. THERE SHALL BE NO DEVIATIONS FROM ARCHITECTURAL DRAWINGS WITHOUT WRITTEN APPROVAL OF THE ARCHITECT. 9. BLOCKING IN PARTITIONS SHALL BE PROVIDED IN ALL AREAS WHERE REQUIRED, WHICH WILL INCLUDE, BUT IS NOT LIMITED TO, OPEN AND CLOSED SHELVING, COAT POLES AND SHELVES, CABINETRY, TENANT SUPPLIED WALL MOUNTED FURNITURE SYSTEMS, COUNTERS, GRAB BARS, FIXTURES OF ANY KIND, AND MOLDINGS/TRIM. 10. GC TO VERIFY ALL DIMENSIONS IN THE FIELD. 11. DIMENSIONS NOTED AS "CLEAR" SHALL BE FROM FINISHED FACE TO FINISHED FACE. 12. GC TO PROVIDE OWNER WITH ALLOWANCE FOR ALL NEW PLUMBING, MECHANICAL AND ELECTRICAL FIXTURES. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARATION OF EXISTING WALL SURFACES TO RECEIVE NEW FINISHES AS SCHEDULED. 5 JASON CANNING ARCHITECT INC ARCHITECTURE PLANNING INTERIORS 1812 Atlantic Blvd. Jacksonville, Florida 32207 O: 904.647.8690 C: 904.755.5589 F: 904.406.7227 j as on@canningarch. coin D DDn ICt'`T ADt-%UlTC/%T u 0 JASON T. CANNING FLORIDA LICENSE'NO. AR95310 PROJECT TEAM OWNER SHAWN JACKREL ARCHITECT JASON T. CANNING 904.647.8690 DATE ISSUE 24 SEPT 2018 PERMIT W CL F_ M O N J z W D M Z Q > U) �O W a �S>_w �JQ �0 Qm �v 0�~ [L 0pW C) Nz JW _ W _`_I �- U U) 0 0 PROJECT NO: 1877 DRAWN BY: DS CHECKED BY: JTC SHEET NO: ■ SHEET u m ICI :m 0E 2 2 SYMBOLS LEGEND 2 4 CEILING TILE NEW GYP. BD. CEILING 1X4 LED LIGHT FIXTURE 2X4 LED LIGHT FIXTURE �F FAN LIGHT COMBO SUPPLY DIFFUSER 4 D EXIT SIGN / EMERGENCY COMBO 4 , 5 REFLECTED CEILING PLAN SCALE: 1/4"=1'-0" N RTH 1 A1.2 SCALE: 1/4" = 1'-0" 0 2.5' 5' 10' 1 n 5 C O c O U CCS O co cn E a) D PROJECT ARCHITECT JASON T. CANNING ec O -+-a O FLORIDA LICENSE NO. AR95310 .o I v w J E O DATE ISSUE SEPT 2018 PERMIT CCS i Z V) Q CL F'- Ce) O N V LLI W d. M U) W J z F- L J O��= 0 W 0 U L LJ �O< Z 090, U Q ry N Z tfo,o Z Q r- Q I— D F- to Q V Q ILL w PROJECT NO: 1877 DRAWN BY: DS CHECKED BY: JTC SHEET NO: Al 2 ■ SHEET �ft C F 1 141 MINIM JM VENTILATION RATES PEOPLE OUTDOOR AIRFLOW AREA OUTDOOR AIRFLOW RATE IN OCCUPANCY OCCUPANT DENSITY TOTAL CFM EXHAUST AIRFLO CLASSIFICATION SQ. FOOTAGE #/1000 SF RATE IN BREATHING ZONE, Ra CFM/ SF BREATHING ZONE REQUIRED RATE CFM/ SF Rp CFM/PERSON RETAIL SALES 2044 15 = 30 PERSONS 7. (x 30) = 225 0.12 (X 2044) = 245 470 - STORAGE 250 - 0.12 (X 250) = 30 30 - OFFICE 140 5 = 1 PERSON 5 (X 1) = 5 0.06 (X140) = 8 13 - 513 TOTAL MECHANICAL SY TEM SCHEDULE DESIGNATION MANUFACTURER MODEL SIZE QTY AHU-1 TEMPSTAR FEM46000131-3 5 TON 1 EXHAUST FAN COOK GC 126-188 70 CFM 1 ION FILTER ULTRA PURE ION -OA ft or more above the floor. 1 MECHANICAL SYMBOLS LEGEND SUPPLY DIFFUS EXHAUSTFAN TRANSFER GRILL THERMOSTAT SUPPLY LINE ASHRAE 62.1 Occupancy Category Sales (except as below) 7.5 Ceiling supply of cool air Building Space Area (sgft) 2507' Building Occupancy Limit 30 ASHRAE 62.1 People Outdoor Air Rate (CFM 1 ASHRAE 62.1 Area Outdoor Air Rate Building Height (ft) 12 Building Activity Level i� Mild Exercise 225 Ceiling supply of warm air 15°F or more above space Building Activity Multiplier 2.5 Breathing Zone Outdoor Airflow (CFM) 526 CO2 output 0.4 ASHRAE 62.1 Zone Air Distribution EffectivnesE I(Ez) 0.8 ASHRAE 62.1 Table 6.2.2.2 AIR DISTRIBUTION CONFIGURATION 7.5 Ceiling supply of cool air 1.0 Ceiling supply of warm air and floor return ASHRAE 62.1 People Outdoor Air Rate (CFM 1 ASHRAE 62.1 Area Outdoor Air Rate 0.12 Zone Primary Airflow (CFM) 225 Ceiling supply of warm air 15°F or more above space i a space Breathing Zone Outdoor Airflow (CFM) 526 ASHRAE 62.1 Zone Air Distribution EffectivnesE I(Ez) 0.8 ASHRAE 62.1 Table 6.2.2.2 AIR DISTRIBUTION CONFIGURATION Ez, Ceiling supply of cool air 1.0 Ceiling supply of warm air and floor return 1.0 Ceiling supply of warm air 15°F or more above space 0.8 temperature and ceiling return. 0.0187870.000'3 Ceiling supply of warm air 15°F or more above space i a space temperature and ceiling return provided that 150 fpm 1.0 supply air jet reaches to within 4.5 ft of floor level. Pass Floor supply of cool air and ceiling return, provided tha 0.06150 the vertical throw is greater than 50 fpm at a height of A.5 1.0 ft or more above the floor. Pass Floor supply of cool air and ceiling return, provided low Pass velocity displacement ventilation achieves unidirectional 0.83400 flow and thermal stratification, or underfloor air 1.2 distribution systems where the vertical throw is less then Pass or equal to 50 fpm at a height of 4.5 ft above the floor. Pass Floor supply of warm air and floor return 1.0 Floor supply of warm air and ceiling return 0.7 Makup supply drawn in on the opposite side of the roorn 0.8 from the ehaust or return Toluene Makup supply drawn in near to the ehaust or return 0.5 location. Pass Total Outside Air Requirement w/o IAQ PKG 657 0.07756 Total Outside Air Desired (using IAQ) 0 Tonnage Savings (using IAQ) 1.' Pass BTU Savings (using IAQ) 179 3 Minimum Outside Air Requirement (using IAQ)** 8. 0.0187870.000'3 **Minimum Outside Air calcualted based on CFM required to meet OSHA CO2 levels of 5,000 ppm given the space conditions. i a space Outside Air Requirement w/o IAQ PKG (CFM per person) 21:' Pass Outside Air Requirement with IAQ PKG (CFM per person) 6. Pass Supply Air 200 Return Air 0 Recirculation Flow Factor 0.00 Return Air Factor 2.29 0.06150 *Calculations based on treatment of outside 'supply' air. Green indicates levels MEET ASHRAE regulations and WRE standards `Orange indicates levels MEET ASHRAE regulations but NOT WRE standards Red indicates levels DO NOT MEET ASHRAE regulations or WRE standards Acetaldehyde 0.07756 OM 0.00836 Pass 0.00856 Pass Benzene 0.0187870.000'3 01 2 0.00202 Pass 0.002`11 Pass Chloroform 0.06150 0.00006 Pass 0.0000"7 Pass 1,4 - Dioxane 0.83400 0.00000 0.00000 Pass 0.00000 Pass Tetrachloroethene 0.00515 0.000 4 0.00031 Pass 01,00032 Pass Toluene 0.07950 0.003j2 0.00387 Pass 0 00400 Pass 1,1,1 - Trichloroethane 0.18300 0.00050 0,00038 Pass 0.00062 Pass Xylene 0.16100 0.001 7 0.00159 Pass 0.00159 Pass Carbon dioxide* 5000 1009 PIKEN65(75 2400 200 Pass 87 ASHRAE M *CO2 provided to validate adequate ventilation with IAQ reduction based onSHA regulatory levels. CO2 not affected by bi-polar air purification. OSHA regulatory levels state a max threshold of 5,000 PPM. WRE calculations run off of a ma acceptable threshold of 3,000 PPM 1 2 El 1 SCALE: 1/4"=1'-0" NORTH � MECHANICAL PLAN M1.0 SCALE: 1/4" = 1'-0" I ' 0 2.5' 5' 10' r•� E3 1.1 I MIN. 70 CFM EXHAUST TO EXTERIOR WITH WEATHERED HOOD JASON CANNING ARCHITECT INC ARCHITECTURE PLANNING INTERIORS 1812 Atlantic Blvd. Jacksonville, Florida 32207 O: 904.647.8690 C: 904.755.5589 F: 904.406.7227 j ason@canningarch. corn D ( PROJECT ARCHITECT N on 0 JASON T. CANNING s FLORIDA LICENSE NO. AR95310 PROJECT TEAM OWNER SHAWN JACKREL ARCHITECT JASON T. CANNING 904.647.8690 DATE ISSUE 24 SEPT 2018 PERMIT noo co z CO ZO N QD rW 2C%)�J W ILL Q Uc� o 2 W c�OQ CU S W : >- W �O<m _, ZZQ J o- v <C W C Qry C1N4 =2 Q�J C� W Q Q W PROJECT NO: 1877 DRAWN BY: DS CHECKED BY: JTC SHEET NO: Imi No SHEET C 0 0 1 1 2 2 PLUMBING FIXTURE SCHEDULE DESIGNATION DESCRIPTION CONNECTION SCHEDULE WASTE VENT CW HW JASON T. CANNING P-1 EWC 2" 1 1/2" 1/2" N/A W SELECTED BY OWNER O W W CO � P-2 MOP SINK 2" 1 1/2" 1/2" 1/2" O� SELECTED BY OWNER ° W ° � I(D —< U P-3 LAVATORY 2" 1 1/2" 1/2" 1/2" FLORIDA LICENSE NO. AR95310 SELECTED BY OWNER ~ CL C) P-4 TOILET 3" 1 1/2" 1/2" N/A SELECTED BY OWNER C.� Q P-5 I NSTA HOT N/A N/A 1/2" 1/2" LL— SELECTED BY OWNER E! CONNECT T" EXISTING DR CONNECT TO EXISTING SUPPLY N RTH 2 SANITARY PLAN P1.0 SCALE: 1/4" = 1'-0" SCALE: 1/4"=l' -O" 0 2.5' 5' 10' /2" P-1 ('4'WATER RISER DIAGRAM P1.0 NTS LEGEND - HOT WATER COLD WATER 0 5 NORTH 1 PLUMBING PLAN P1.0 SCALE: 1/4" = l'-0" SCALE: 1/4"=1'-0" 0 2.5' 5' 10' LEGEND - HOT WATER COLD WATER CONNECT TO EXISTING DRAIN 2" VTR J' L P-1 SANITARY AND VENT RISER DIAGRAMS NTS LEGEND VENT WASTE 5 4) cn JASON CANNING ARCHITECT INC ° ARCHITECTURE PLANNING INTERIORS 1812 Atlantic Blvd. Jacksonville, Florida 32207 O: 904.647.8690 O C: 904.755.5589 'U) F: 904.406.7227 1U) jason@canningarch.com � D Q PROJECT ARCHITECT z JASON T. CANNING 'c: ~ m <co W z O O W W CO � R W LL O� ° W ° � I(D —< U CL 3: >- < z O FLORIDA LICENSE NO. AR95310 ~ CL C) v oil 0 DATE ISSUE SEPT 2018 PERMIT L -1-.+ O 4-+ -- N CLX O O O .c c C� O 0 z ~ co <co W z O W W CO � W LL O� ° W ° � I(D —< U CL 3: >- < z ~ CL C) � N z0S W C.� Q CL LL— co PROJECT NO: 1877 DRAWN BY: DS CHECKED BY: JTC SHEET NO: Pi ■ 0 SHEET x m A 0 1 1 2 2 4 5 NORTH 1 LIGHTING PLAN E1.0 SCALE: 1/4" = V-0" ■ V 1N JASON CANNING ARCHITECT INC ARCHITECTURE PLANNING INTERIORS 1812 Atlantic Blvd. Jacksonville, Florida 32207 O: 904.647.8690 C: 904.755.5589 F: 904.406.7227 jason@canningarch.com PROJECT ARCHITECT JASON T. CANNING r FLORIDA LICENSE NO. AR95310 PROJECT TEAM OWNER SHAWN JACKREL ARCHITECT JASON T. CANNING 904.647.8690 DATE ISSUE 24 SEPT 2018 PERMIT 1X4 LED LIGHT FIXTURE i 2X4 LED LIGHT FIXTURE FAN LIGHT COMBO 4 D M ® EXIT SIGN / EMERGENCY COMBO -69— SWITCH �GFI G.F.I. OUTLET CLNG CEILING OUTLET DUPLEX OUTLET ■ V 1N JASON CANNING ARCHITECT INC ARCHITECTURE PLANNING INTERIORS 1812 Atlantic Blvd. Jacksonville, Florida 32207 O: 904.647.8690 C: 904.755.5589 F: 904.406.7227 jason@canningarch.com PROJECT ARCHITECT JASON T. CANNING r FLORIDA LICENSE NO. AR95310 PROJECT TEAM OWNER SHAWN JACKREL ARCHITECT JASON T. CANNING 904.647.8690 DATE ISSUE 24 SEPT 2018 PERMIT E—' ry M Z 0 M N z W D cM Q � � W > ry w LJt_ k* w W � _ V C >-w Z Q � pp — ~ U Z NOTC4 z Q C� FW- Q Q PROJECT NO: 1877 DRAWN BY: DS CHECKED BY: JTC SHEET NO: El NO SHEET I0 m ICS "M w nM a 2 SURFACE MTD. CIRCUIT BREAKER TYPE STAB-LOK PANEL A 120/208 VOLTS 3 PHASE 200 AMP WIRE CKT NO. DESIGNATION CIRCUIT LARGEST MOT CIRCUIT BREAKER = 1.95 KVA R (2 X 1.5=3) KVA CIRCUIT BREAKER SF X 3VA/SF CIRCUIT SIGN DESIGNATI N CKT NO. WIRE COND POLE TRIP TRIP POLE COND WIRE 1 AHU 8 3/4 2 60 10 1.5 20 1 1/2 12 RECEPTACLES O I� 2 3 = 1.5 20 1 1/2 12 RECEPTACLES 4 5 COND 8 3/4 2 30 4.0 1.5 20 1 1/2 12 RECEPTACLES I- 6 7 ^Q Q V Q n 1.5 20 1 1/2 12 RECEPTACLES 8 9 INSTA HOT 12 1/2 1 20 1.5 1.5 20 1 1/2 12 RECEPTACLES PROJECT NO: 1877 10 11 INSTA HOT 12 1/2 1 20 1.5 1.5 20 1 1/2 12 RECEPTACLES 12 13 RECEPTACLES 12 1/2 1 20 1.5 1.5 20 1 1/2 12 RECEPTACLES 14 15 RECEPTACLES 12 1/2 1 20 1.5 1.5 20 1 1/2 12 LIGHTING 16 17 RECEPTACLES 12 1/2 1 20 1.5 1.5 20 1 1/2 12 LIGHTING 18 19 SPACE SPACE 20 21 SPACE SPACE 22 23 SPACE SPACE 24 25 SPACE SPACE 26 27 SPACE SPACE 28 29 SPACE SPACE 30 31 SPACE SPACE SPACE SPACE 32 34 36 33 SPACE 35 SPACE 37 SPACE SPACE 38 39 SPACE SPACE 40 41 SPACE SPACE 42 TOTAL AMPS 78.5 DEMAND K A 28.25 42,000 AMP SYMMETRICAL SHORT CIRCUIT CURRENT RATING @a 240V, 3PH * ALL CONTRACTORS TO FIELD VERIFY LOAD CALCULATIONS AHU-1 (5KW HEAT) = 6.3 COND-1 U) = 7,8 LARGEST MOT R - 7.8 X.25 = 1.95 WATER HEAT R (2 X 1.5=3) = 3 LIGHTING - 2,:07 SF X 3VA/SF = 7.5 SIGN = 1.5 OUTLETS - 15 UPLEX X 180/OUTLET = 2.7 TOTAL KVA co N 28.25 D wCL0M /1.73 Z 16.33 W� �� /208 J o 0 78.5 Existing Servicelis 200 Amp, 3 Phase, 120/208 Volt 4 -- 1 5 1 POWER PLAN N RTH E1.1 SCALE: 1/4" = 1'-0" '---OVERHEAD RISER 2 1/2" IMC (4) 4/0 ALUM 200 AMP 30 120/208 VOLT METER (4) 4/0 ALUM 200 AMP 30 0 120/208V DISCONNECT (4) 4/0 ALUM (1) 2/0 ALUM -BARE #4 COPPER GROUND ---(2) 5/8 GROUND RODS 2 NEW RISER DIAGRAM E1.1 SCALE: NTS 11 INSIDE WALL 200 AMP 30 240 VOLT 42 CIRCUIT MLO PANEL i � 2 3 4 5 � u v u JASON CANNING ARCHITECT INC ARCHITECTURE PLANNING INTERIORS 1812 Atlantic Blvd. Jacksonville, Florida 32207 O: 904.647.8690 C: 904.755.5589 F: 904.406.7227 jason@a canningatch.com PROJECT ARCHITECT JASON T. CANNING FLORIDA LICENSE NO. AR95310 PROJECT TEAM OWNER SHAWN JACKREL ARCHITECT JASON T. CANNING 904.647.8690 DATE ISSUE 24 SEPT 2018 PERMIT U) U U) J CU F- ry O co N w J D wCL0M Z Q W� �� J o 0 W = n- w O I� w O v = �p<m wC/)Q Q� Nz OwCD z Q Irl -J n Z I- I .._ ^Q Q V Q n Q NN L.Lo w U) PROJECT NO: 1877 DRAWN BY: DS CHECKED BY: JTC SHEET NO: El ■ 1 SHEET