Loading...
362 PLAZA - JEA ROW '"''�'' RIGHT OF WAY PERMIT PERMIT NUMBER '----k;'-,i'''.''' CITY OF ATLANTIC BEACH ROW18-0040 V~ 800 SEMINOLE ROAD ISSUED: �Oi31vr ATLANTIC BEACH. FL 32233 EXPIRES: MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 362 PLAZA RIGHT OF WAY COMMERCIAL 2 Pole Replacements & $0.00 RIGHT OF WAY Transformer TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: 169972 0005 ATLANTIC BEACH COMPANY: ADDRESS: CITY: STATE: ZIP: JEA OWNER: ADDRESS: CITY: STATE: ZIP: MERRIAM RICHARD A 4451 MENDENHALL DR DALLAS TX 75244 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 2 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration,including sod,is required. Issued Date: 1 of 2 RIGHT OF WAY PERMIT t, PERMIT NUMBER r '. CITY OF ATLANTIC BEACH ROW18-0040 J�° V 800 SEMINOLE ROAD ISSUED: ATLANTIC BEACH. FL 32233 EXPIRES: 3 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL Notes: Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed,call 247-5878. 4 PUBLIC UTILITIES UTILITY MAP INFORMATIONAL Notes: See attached Utility Map. FEES . . ..� DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT TOTAL: Issued Date: 2 of 2 ol..ty r, City of Atlantic Beach rCEnni APPLICATION NUMBER Building Department ^'(To be assi ned b the Buildin De rtment.f` 9 Y 9 P ) 800 Seminole Road QV , 6 2018 - 601/6 , Atlantic Beach, Florida 32233-5445 a U Phone(904)247-5826 • Fax(904)247-58455: 0566 E-mail: building-dept@coab.us Date routed: ( 15 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: NCI r 14-.2-a-- ( 3(0I Department review required Yes No r^^� B iilrlincJ Applicant: C LTA Planning &Zoning Tree Administrator Project: 2- t: (f' S "Tran Scorivler ubli ublic Utilities o ` t&-Z Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLI ON STATUS Reviewing Department First Review: Approved. ['Denied. ['Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: /1�9/r TREE ADMIN. Second Review: A roved as revised. ❑ pp ['Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ['Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 0).- are., City of Atlantic Beach EC IVE APPLICATION NUMBER IA Building Department (To be assigned by the Building Dep rtment.) ' 800 Seminole Road 0 , Atlantic Beach, Florida 32233-544 NOV 16 2018 �o w j - v Q 6 Phone(904)247-5826 • Fax(904) -5845 l l A�_0;3 9' E-mail: building-dept@coab.us BY:_____________ Date routed: / /�/ City web-site: http://www.coab.us /// APPLICATION REVIEW AND TRACKING FORM Property Address: 3CQ Z- .P14-2-a- (3(.o i Department review required Yes No ' t Applicant: `� Planning &Zonin I Tree dministrator Project: 2— 'P (h S —Iran Scbrii nerubli ublic Utilitie_ C3 ` �a:La Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: 140:1 Faate: fr-vf_7/' TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 City of Atlantic Beach APPLICATION NUMBER cBuilding Department (To be assigned by the Building Dep rtment) \0\\ 2 800 Seminole Road �Q ', A i ;, — 6° a r '�' •� '� Atlantic Beach, Florida 32233-5445 �J�J a J r Phone (904)247-5826 • Fax(904)247-5845 E-mail: building-dept@coab.us Date routed: f I / isfi 11 City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 3(422- P 14.2-cL C36 Department review required Yes No Applicant: V Planning &Z, oning Tre—eAdministrator Project: 2 P-Pbtt S \ -Iran Si)rrv1er ubli ublic Utilitiej) C.136 ‘ Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: -% A .proved. Denied. t1 of applicable (Circle one.) Comments: BUILDING PLANNING & ZONING Reviewed by: o Date: /�-2. ( - 1 .1c 1 O TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. I (Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 Pvtio 4 11.,! q '',;"1; d ,. M1 t A Y rA ,fit 7` - •w di= ' .m • f ! e ! I /♦ t moi, ., - t : '' M — "'k. " 1 J ,..:f,4',a a•two ,L.._,_, ..... r, ✓ DR '� ¢ • '" I `, t ' «.,- �,, .fit , lik ` 1,+"'f ,- .. • r• M ,ill'r ` i' .+�t-b fP ,. &` `� •.,,;' 4 1 et - n' \ v °i.ssg .-.ski ,SY 1S+�"'' '.sr' _ _ C> _ - '�I i `q, + a - r 41,,,,, If • I r I: rogi„ ,,,, . & 4.... . - - ---- " :Nr ''''''' ' !ill:14 04 Ate . r. y • p se. it`IR � 4 _ / t I' �/S.r�� ! Jy .. Al co oe? 1. 3 y ,, - i , . • , . , ,Nt A Ail, titiii.a.„.„.t,_..............._„...- i . . : . Il 1 it 1 CO • w g ' ts•RC e r df / - Ma !f RIGHT-OF-WAY/ EASEMENT PERMIT APPLICATION **ALL INFORMATION City of Atlantic Beach HIGHLIGHTED IN GRAY IS 800 Seminole Road,Atlantic Beach,FL 32233 REQUIRED. • PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES Job Address 361 PLAZA Permit Number Contractor Information Company JEA Qualifying Agent Address 21 WEST CHURCH ST. City JACKSONVILLE State FL Zip 32202 Phone Email State Certification/Registration# Architect Phone Email Engineer R.SIMPSON Phone 665-7793 Email SIMPRB@JEA.CPM Workers Compensation Insurer-F-1 OR Exempt©Expiration Date • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities,both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,Improvement,maintenance,safe and efficient operation,alteration or relocation of all,or any portion of said street or easement as determined by the Public Works Director,any or all said poles, wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be Immediately removed from said street or easement or reset or relocated hereon as required by the Public Works Director and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of R.SIMPSON (Project Superintendent) with (Company Name) JEA Phone • All materials and equipment shall be subject to inspection by the Public Works Director. • All city property shall be restored to its original condition as far as practical,in keeping with City specifications and the manner satisfactory to the,City. • • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. •. The permittee shall commence actual construction in good faith within 60 days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Public Works Director to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right, title and interest in the land to be entered upon and used by the holder,and the holder will,at all times,assume all risk of and indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. • The Public Works Director shall be notified 24 hours prior to starting work and again immediately upon completion. Date Permittee(signed in presence of Notary Public) STATE OF FLORIDA,COUNTY OF DUVAL The foregoing instrument was acknowledged this day of ,20 by ,who personally appeared before me and (printed name of Permittee) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. [ ]Personally Known Signature of Notary Public,State of Florida [ ]Produced Identification(Type) H:\Applications&Forms\Word Documents\201801001 Right-of-Way Easement Permit Application.docx Revision Date:10/1/18 .. RIGHT-OF-WAY/ EASEMENT PERMIT -- L;: ,r Permit#Issued by the City of Atlantic Beach PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES Job Address 36/ 7/et,A Phone 66r- 72 93 Permittee 3-6/4 Email Sian,,f0(lo (? J e ei • eoevi Requesting Permission to Construct CL) c k (1i 1 .-te d3 d- ✓ows — (I) rl 6.13 w ok(t) 3s/E!�✓ Location(Reference to Cross-Street) SjAer'S L)t • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement, maintenance,safe and efficient operation, alteration or relocation of all,or any portion of said street or easement as determined by the Director of Public Works,any or all said poles,wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of Q. Si'✓ri pSlh-i (Project Superintendent) with Company Name T e'f Phone 196 5 - 77 9 3 • All materials and equipment shall be subject to inspection by the Director of Public Works. • All city property shall be restored to its original condition as far as practical, in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • The permittee shall commence actual construction in good faith within days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,title and interest in the land to be entered upon and used by the holder,and the holder will,at all times, assume all risk of and indemnify, defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. • Th irector of Pt . 1 Works shall be notified twenty-four(24)hours prior to starting work and again e iate u o .mpletion. // Date ///���cp- Permittee(signe in p •sem e of Notary Public) STATE OF FLORIDA,COUNTY OF DUVAL The foregoing instrument was acknowledged this day of ,20 by ,who personally appeared before me and (printed name of Permittee) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. Personally Known Signature of Notary Public,State of Florida Produced Identification(Type) ENGINEERING DESIGN ORACLE PERMIT MAXIMO DATE REL ' PROJECT#:35599 N,0.: 8005212 WO#: 30360433 CONST: 11/15/18 CIR. TREE TRIMMING SUB-STA: NEPTUNE BEACH N.O.: 563 REQ'D:NO CELL ENGINEER:Robert Simpson N.O.: N/A ZIP CODE: N/A CUSTOMER/ SVC PHONE LOCATION: 361 PLAZA I POLE REPLACEMENT 563 CENTER: SSSC N.O.:665.7793 STA 1. P# 361 PLAZA! R&R 45/3W, INSTALL _ w .-- - -"- 25KVA, RUN 4/OP TO STA 2. o C IT 1 2T - STA 2, P# 360 PLAZA./ R&R 35/4W. 2T ***** LANE CLOSURE REQUIRED ***** 4 1/OT I 4 4 346 340 336 334 1 364 358 354 350 344 343 337 376 372355-1 349 4 4 380 369 363 349 4 4 5 377 371 4 375 STA 1 4/01 ♦ 355 1/OT 1/01 1/01 1/0T ui W n W T 1/OT I N W T nW T o J U1 4�OP T nLn 4/0 _• C li Q PLAZA N - -o 2 OP 4C.V_- Cr- d- _ _ - 4CU N 4/OP --- v • • -4 AO_ �►An 1/01- 1111r'' 1/0T 1/0T STA 2 1/OT 1 4 4 352 348 344 338 354 350 SHERRY DR 2 358 347 341 37: 374 IIMPAIiiii365 359-1 345 371 ♦ 349 CUE Reports Estimate Number:35599 361 PLAZA/45/3W POLE Estimate Type:SR Contract:089-16-HM OH FY19 REPLACEMENT Estimate Version: By: SIMPRB MWO#/Task:30360433 Required Date: Oracle Project#:8005212 Estimated On: 10/26/2018 Cost Estimate Materials JEA Contractor 1.New Material Cost(w/sales tax) $1,648.69 $1,648.69 2.Transformer Cost(w/sales tax) $1,028.37 $1,028.37 3.Returned Material Salvage Value $0.00 $0.00 Labor 4.Crew Time $1,369.09 $3,773.72 5.Extraordinary Costs $0.00 $0.00 JEA Overhead 6.Fringe Benefits(54.56%of lines 4&7) $899.42 $277.13 7.Engineering Costs(Variable%of line 4) $279.40 $507.94 8.Project Equipment Costs(40%of total equipment costs) $809.92 $0.00 9.Material Handling(8.30%of lines 1&2) $222.20 $222.20 10.Inspection(6.84%of line 4) $0.00 $258.12 11.Total Cost of Project $6,257.08 $7,716.18 12.Work Order Estimate(Line 11 minus line 8,9,&10) $5,224.97 $7,493.98 13.Billable Equipment Depreciation(60%of total equipment costs) $1,214.87 $0.00 14.Billing Estimate(Including Transformer Cost)(Lines 11+13+(58.71%of 4&7)) $8,439.78 $8,014.39 15.Billing Estimate(W/O Transformer Cost)(Lines 11+13+(58.71%of 4&7)-Line 2) $7,411.41 $6,986.02 Time Estimate Crew Hours Total Manhours 10.98 43.91 • JE' CUE Reports Estimate Number:35599 361 PLAZA!45/3W POLE Estimate Type:SR Contract:089-16-HM OH FY19 REPLACEMENT Estimate Version: By: SIMPRB MWO#lTask:30360433 Required Date: Oracle Project#:8005212 Estimated On: 10/26/2018 CU Detail Station:01 361 PLAZA Build Transfer Remain In Place Remove C.4/0P 125 DA1F-5 1 DA1 F-5*2 1 DGAC 1 DGAC*25 1 G1W*2 1 P.45/3W 1 RUBUP 4 S2OES*2/0-1/0 3 S20ES*4/0-410 1 Cl. /0T 125 CUT 3 DEYE 2 NUMBER 1 P.45/3W 1 PIN 1 POLECON 4 • PRIINS 1 RUBDOWN 4 SEC 2 SECINS 2 SMWEDGE 4 STANDOFF 1 TANGENT 2 WOODGRD 1 Station:2 360 PLAZA Build Transfer Remain In Place Remove G3W*2 1 GY3-A*5 2 P.35/4W 1 S2OES*4/0-1/0 2 S4*4/0 1 S9*1/0 2 SEVP 1 JEj. CUE Reports Estimate Number:35599 361 PLAZA/45/3W POLE Estimate Type:SR Contract:089-16-HM OH FY19 REPLACEMENT Estimate Version: By: SIMPRB MWO#/Task:30360433 Required Date: Oracle Project#:8005212 Estimated On: 10/26/2018 CUT 3 DEYE 2 DOWN3/8 2 NUMBER 1 P.35/4W 1 POLECON 2 SMWEDGE 2 TANGENT 1 WOODGRD 1 JEA. CUE Reports Estimate Number:35599 361 PLAZA/45/3W POLE Estimate Type:SR Contract:089-16-HM OH FY19 REPLACEMENT Estimate Version: By: SIMPRB MWO#/Task:30360433 Required Date: Oracle Project#:8005212 Estimated On: 10/26/2018 Material Summary Item Quantity Item Number item Description 2 ARRLI003 ARRESTER, LIGHTNING, 18 KV, DISTRIBUTION CLASS AND RISER POLE(MOV)WITHOUT MOUNTING BRACKET, 15.2/26.4Y NOMINAL VOLTAGE 2 BKTAC009 BRACKET,ARRESTER AND CUTOUT, FIBERGLASS WITH RAYCHEM MATERIAL OVER ROD TYPE:SINGLE PHASE 2 BKTFS001 BRACKET, FIBERGLASS STANDOFF,2" FIBERGLASS ROD, 18" STANDOFF TO INS BASE ROD COVERED WITH RAYCHEM HEAT- SHRINK MATERIAL, DUCTILE IRON FITTINGS 2 BOLDA015 BOLT, 3/4"X 14", DOUBLE ARMING, GALV.WITH 4 SQUARE NUTS ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 2 BOLMS020 BOLT, MACHINE, 5/8"X 14", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 50 EACH) 7 BOLMS035 BOLT, MACHINE, 3/4"X 12", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 2 BOLMS036 BOLT, MACHINE, 3/4"X 14", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 125 CAIOS003 CABLE,4/0-19(PAP), OVERHEAD SERVICE DROP,600 VOLT MULTIPLEX CABLE"VICKSBURG"PRE-ASSEMBLED PARALLEL 1000 FOOT REELS 2 CLAGROO1 CLAMP, GROUND ROD, 5/8"-4SOL"HAMMERLOCK" 1 CLASR002 CLAMP, STRAIN RELIEF WEDGE,ALUMINUM, 1/0 TRI-4/0 PAP • 5 CLASR003 CLAMP, STRAIN RELIEF WEDGE MESSENGER, SIZE:#6-2/0 1 CLASS006 CLAMP, STRAIGHT STRAIN,ALUMINUM, 10000#3/0-556 ALUM (STD PKG 15 EA) 2 CLATG001 CLAMP,TRANSFORMER TANK GROUND, "BRONZE"6 SOL- 1 STR. 6 CNNCP002 CONNECTOR,#2,6-2 MAIN, 2-1/0 TAP,ALUMINUM COMPRESSION, PARALLEL TAP, 10 CNNCP004 CONNECTOR,#4, 1/0-2/0 MAIN, 1/0-3/0 TAP COMPRESSION, PARALLEL TAP,ALUMINUM, 3 CNNCP005 CONNECTOR,#3,6-2 MAIN, 2/0-3/0 TAP, COMPRESSION, PARALLEL TAP,ALUMINUM, 4 CNNCP006 CONNECTOR,#6, 1/0-2/0 MAIN, 3/0-4/0 TAP COMPRESSION, PARALLEL TAP,ALUMINUM, 3 CNNCP007 CONNECTOR,#7, 3/0-4/0 MAIN, 3/0-4/0 TAP COMPRESSION, PARALLEL TAP,ALUMINUM, 2 CNNCP008 CONNECTOR,#5, 6-2 MAIN, 4/0 TAP, COMPRESSION, PARALLEL TAP, ALUMINUM, 2 CNNGROO2 COUPLING, GROUND ROD, "THREADLESS"REMARKS: FOR THREADLESS GROUND RODS 3 CNNTS009 CONNECTOR,CONTAMINATED ENVIRONMENT,TRANSFORMER SECONDARY SET SCREW TYPE WITH INHIBITOR, 1/2"STUD, RANGE: 12-350,6-PORTS. CUE Reports Estimate Number:35599 361 PLAZA/45/3W POLE Estimate Type:SR Contract:089-16-HM OH FY19 REPLACEMENT Estimate Version: By: SIMPRB MWO#ITask:30360433 Required Date: Oracle Project#:8005212 Estimated On: 10/26/2018 8 CNNVG003 CONNECTOR, 6-2 SOL/10-2 SOL,VISE GRIP PARALLEL, BRONZE 72 COBC0028 CONDUCTOR,#4 SOLID, SOFT DRAWN, BARE COPPER, 200', 25#,ON PLASTIC REEL,4"X 11.5"W/2" HOLE 140 COBCW014 CONDUCTOR, #4,TYPE 40 DSA, COPPERWELD&COPPERWELD- COPPER.204" DIAMETER 1480#BREAKING STRENGTH ( 50#COIL- 427' ) 20 COVIC002 COVER, "D"DIE, INSULATING,2-1/2" 2 CUTOT006 CUTOUT, CONTAMINATED ENVIRONMENT, 26" LEAKAGE DISTANCE TO GROUND, 100A,27 KV, 170 KV BIL (54 EA PER PALLET) 1 FUSOH022 FUSE, OVERHEAD DISTRIBUTION, 1.6 AMP, TRANSFORMER 2 GUAGW001 GUARD, GROUND WIRE, 1/2"X 1/2"X 96", GRAY PLASTIC 2 GUAGW002 GUARD, "YELLOW", GUY WIRE, 1/4"TO 1/2"8', POLYETHYLENE, USED ON ALL 3/8"AND 7/16"GUY STRANDS (DISTRIBUTION) 2 GUYAT008 GUY HOOK,COMBINATION, MALLEABLE OR DUCTILE IRON, HOT DIP GALV. 13/16" MOUNTING HOLE,20,000 LB MIN. ULT. STRENGTH. FOR WOOD OR CONCRETE POLES 4 GUYGR001 GRIP, GUY,3/8", 26", GALVANIZED 100 GUYST005 STRAND,GUY, 3/8" DIA,7 PER STRAND, GALVANIZED STEEL, CLASS "B"GALV. OR BEZINOL IS ACCEPTABLE (500'COIL) 2 INSGB002 INSULATOR, STRAIN, GUY BREAKER,21,000#RATED,60" ROD LENGTH, FIBERGLASS FOR USE ON JEA'S DISTRIBUTION SYSTEM ONLY 1 INSS0002 INSULATOR, SUSPENSION,4", CLASS 52-9 NEMA STRENGTH 10000#, GALV. FITTINGS 2 INSVP001 INSULATOR, VERTICAL POST,TIE TOP 35-KV,3/4"STUD TAP STANDARD PACKAGING IS NOT TO EXCEED THREE UNITS OR 72 POUNDS. 4 NUTSL003 NUT, LOCK,SQUARE, 5/8"HOLE SIZE, HOT DIPPED GALVANIZED 4 NUTSLOO4 NUT, LOCK,SQUARE, 3/4"BOLT SIZE, HOT DIPPED GALVANIZED 1 POLW0003 POLE, WOOD, 35'CLASS 4 (T/L=44), WEIGHT=1,026 LBS 1 POLW0006 POLE, WOOD, 45'CLASS 3 (T/L=26), WEIGHT=1,770 LBS 4 RODGR003 ROD, GROUND, THREADLESS,5/8"X 8', SHIP ON OPEN FLATBED ONLY! 2 SLEAL003 SLEEVE, RED TO RED NEUTRAL 2-2 ALUMINUM TRIPLEX NEUTRAL SPLICING 2 STULI001 STUD, LINE POST, DIA. SHANK-3/4", SHANK LENGTH-1-3/4", GALVANIZED STEEL W/NUTS AND WASHERS;3/4"HEAD SIZE 2 TAGH0007 ALUMINUM VERTICAL TAG HOLDER FOR ADHESIVE BACK CHARACTERS((NOT FOR"SLIDE IN"CHARACTERS)). 19.5"HIGH X 2" WIDE WITH 3-1/8" NAIL HOLES @ THE TOP AND THE BOTTOM. (PKG. OF 50 EACH) 1 TIEPR00I TIE, PREFORMED LINE,#2 MAC,23" MIN. LENGTH, "F"NECK, SIDE TIE .316"-.357"COND. RANGE 1 TRAC0001 TRANSFORMER, 25 KVA, 14760/25565Y VOLT PRIMARY, 120/240 VOLT SECONDARY,SINGLE PHASE, CONTAMINATED ENVIRONMENT 4 WASRD004 WASHER, ROUND, 5/8"BOLT SIZE X 1 3/4" DIAMETER, GALVANIZED, 650 EA P/BOX) 19 WASRD005 WASHER,ROUND, 3/4"BOLT SIZE X 2"DIAMETER, GALVANIZED,*** 500 EACH PER BOX*** `E1, CUE Reports Estimate Number:35599 361 PLAZA/45/3W POLE Estimate Type:SR Contract:089-16-HM OH FY19 REPLACEMENT Estimate Version: By: SIMPRB MWO#/Task:30360433 Required Date: Oracle Project#:8005212 Estimated On: 10/26/2018 11 WASSF003 WASHER,SQUARE FLAT, 3"SQ X 1/4",5/8"X 3/4"BOLT SIZE, GALVANIZED 7 WASSP002 WASHER,SPRING,3/4"BOLT SIZE, DOUBLE COIL HELICAL TYPE, GALVANIZED(EXTRA HEAVY DUTY) JA' CUE Reports Estimate Number:35599 361 PLAZA/45/3W POLE Estimate Type:SR Contract:089-16-HM OH FY19 REPLACEMENT Estimate Version: By: SIMPRB MWO#/Task:30360433 Required Date: • Oracle Project#:8005212 Estimated On: 10/26/2018 CU Summary CU Name Quantity Description C.4/0P 125 4/0 AAC PAP W/4/0 AAAC NEUTRAL DA1 F-5*2 1 2 TANGENT TO 10 DEGREE ANGLE-UNSHIELDED, CONTAMINATED DGAC*25 1 TRANS; CI, 26.4KV 120/240 25KVA G1W*2 1 WOOD POLE- EQUIPMENT GROUND G3W*2 1 WOOD POLE- NON-EQUIPMENT GROUND GY3-A*5 2 3/8"DOWNGUY WITHOUT ANCHOR P.35/4W 1 35 FT.CLASS 4 WOOD POLE P.45/3W 1 45 FT. CLASS 3 WOOD POLE RUBUP 4 LINE RUBBER INSTALLATION, PER SECT. S20ES*2/0-1/0 3 S20ES*2/0-1/0 S20ES*4/0-110 2 SECONDARY CONNECTION AT POLE S20ES*4/0-4/0 1 SECONDARY CONNECTION AT POLE S4*4/0 1 SECONDARY DEADEND S9*1/0 2 SECONDARY SPLICE SEVP 1 SEVERE COND. FOR POLE SETTING CREW REMOVE CU Name Quantity Pescriptioq C.1/OT 125 1/0 TRIPLEX CUT 6 CUT POLE OR CROSSARM DEYE 4 S6 REMOVAL DOWN3/8 2 3/8 IN. DOWNGUY REMOVAL NUMBER 2 POLE TAG REMOVAL P.35/4W 1 35 FT. CLASS 4 WOOD POLE P.45/3W 1 45 FT. CLASS 3 WOOD POLE PIN 1 INSULATOR PIN REMOVAL POLECON 6 S20 REMOVAL PRIINS 1 PRIMARY INSULATOR REMOVAL RUBDOWN 4 LINE RUBBER REMOVAL, PER SECT. SEC 2 SEC.SPOOL INS. BRACKET REMOVAL SECINS 2 SEC. INSULATOR REMOVAL SMWEDGE 6 SMALL SEC. WEDGE CLAMP REMOVAL STANDOFF 1 PRI. INSULATOR STANDOFF BRACKET REMOVAL TANGENT 3 S7 REMOVAL WOODGRD 2 WOOD POLE NON-EQUIP. GRD REMOVAL