Loading...
275 SHERRY DR - PAVER PATIO s"'`i` ACCESSORY PERMIT PERMIT NUMBER ir, ACC18-0051 or. CITY OF ATLANTIC BEACH,� _ 800 SEMINOLE ROADISSUED: -'1Oi3'9` ATLANTIC BEACH. FL 32233 EXPIRES: MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts,state agencies, or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 275 SHERRY DR ACCESSORY SINGLE OR TWO PAVER PATIO, FIRE PIT, $15000.00 FAMILY ACCESSORY WALLS & COLUMNS TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: 169802 0000 MILBERT HOMES S/D COMPANY: ADDRESS: CITY: STATE: ZIP: BEST VIEW BRICK PAVERS OWNER: ADDRNS: CITY: STATE: ZIP: BILL GALLAGHER 275 SHERRY DR ATLANTIC BEACH FL 32233 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line(904-247 -5814)to request an Erosion and Sediment Control Inspection prior to start of construction. 2 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. Issued Date: 1 of 2 e“,' �� ACCESSORY PERMIT PERMIT NUMBER rW CITY OF ATLANTIC BEACH ACC18-0051 800 SEMINOLE ROAD ISSUED: 1-`' ATLANTIC BEACH. FL 32233 EXPIRES: 3 PUBLIC WORKS POST CONSTRUCTION TOPO SURVEY INFORMATIONAL Notes: If on-site storage is required,a post construction topographic survey documenting proper construction will be required. All water runoff must go to retention area and retention overflow must run to street. 4 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list(Advanced Disposal,Realco Recycling,Shapells, Inc.,Republic Services,Donovan Dumpsters, !Phillips Containers). Container cannot be placed on City right-of-way. 5 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration,including sod,is required. 6 PUBLIC WORKS RUNOFF INFORMATIONAL Notes: All runoff must remain on-site. Cannot raise lot elevation. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $130.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $65.00 BUILDING PLAN REVIEW RESUBMITTAL SECOND 455-0000-322-1006 0 $50.00 PW REVIEW BUILDING MOD OR ROW 001-0000-329-1004 0 $25.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $3.68 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.45 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $50.00 TOTAL:$326.13 Issued Date: 2 of 2 o L.J-virjo City of Atlantic Beach APPLICATION NUMBER i aS i, Building Department �'� (To be assigned by the Building Department.) :i : 800 Seminole Road E'l S l ,� ;, Atlantic Beach, Florida 32233-5445 Phone (904)247-5826 - Fax(904)247-5 SEP pE `'2,0;3 q: E-mail: building-dept@coab.us 28 201p Date routed: Z w ( City web-site: http://www.coab.us m� APPLICATION REVIEW AND TRA KING FORM Property Address: Z 7 S S R IIRJepartment review required Yes No Applicant: nEf-2_,,..„ �MC arming &Zonin 3 pp S Y �� � Tree Adminis ra or Project: p_ fa. Loa aoLoin c Work (-Public Utilities t�C 1- L ( l Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date d of Permit Verified By nn Florida Dept. of Environmental Protection ��lv Florida Dept.of Transportation l.�©� St.Johns River Water Management District 11 C VV Army Corps of Engineers P`1 Division of Hotels and Restaurants 67- / C Division of Alcoholic Beverages and Tobacco �0 Other: \ APPLICATION STATUS Reviewing Department First Review: nApproved. [41Denied. nNot applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: eel? TREE ADMIN. Second Review: IT4pproved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES s PUBLIC SAFETY Reviewed b . Date:��/p, FIRE SERVICES Third Review: nApproved as revised. ['Denied. ['Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 I J , s, CITY OF ATLANTIC BEACH f\ Department of Public Works '� r. 1200 Sandpiper Lane \\ Atlantic Beach, FL 32233 --)--- 169, (904) 247-5834 PUBLIC WORKS PLAN REVIEW COMMENTS Date: 9/28/18 Applicant: Best View Brick Pavers &Stone Permit#: ACC18-0051 Email: chadelderb@comcast.net Review Status: DENIED Property Owner: William Gallagher Site Address: 275 Sherry Drive Email: william.gallagher34@comcast.net THIS PLAN REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS Correction Items must be submitted to the Building Department at 800 Seminole Road. Submittals that respond to only one or a few correction items will not be accepted. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions must be submitted to the Building Department and must respond to EACH department review. PUBLIC WORKS CORRECTION ITEMS: • Provide drainage plans showing site topography (flow arrows, etc.). • Section 24-66(b) of the Land Development Regulations requires on-site storage for increased runoff if adding 400 SF or more impervious surface. Provide Delta volume calculations and on-site retention required per Section 24-66(b). • Documentation shows impervious areas are over the 50% allowed by City code. • Entire backyard is water retention area from the house built in November 2016 (Permit#16-SFR-2664). APPROVED PUBLIC WORKS CONDITIONS OF APPROVAL: //�/6 �/� (The following comments will be printed on your permit as Conditions of Approval) • Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (247-5814) to request an Erosion and Sediment Control Inspection prior to start of construction. • All runoff must remain on-site during construction. • If on-site storage is required, a post construction topographic survey documenting proper construction will be required. All water runoff must go to retention area and retention overflow must run to street. • Roll off container company must be on City approved list (Advanced Disposal, Realco Recycling, Shapell's, Inc., Republic Services, Donovan Dumpsters, Phillips Containers). Container cannot be placed on City right-of-way. • Full right-of-way restoration, including sod, is required. • All runoff must remain on-site. Cannot raise lot elevation. Scott Williams, Public Works Director swilliams@coab.us/904-247-5834 Page 1 of 2 O:\Public Works\ADMIN\PLAN REVIEW COMMENTS\ACC18-0051(Best View).docx ti Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with "clouding". The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud. The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with revisions shall be inserted into each set of drawings. The original sheets must be clearly marked "VOID" but are to be left within the set of drawings. Complete new sets of drawings will not be accepted. ADDITIONAL ITEMS MAY BE REQUIRED DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW. Page 2 of 2 0:\Public Works\ADMIN\PLAN REVIEW COMMENTS\ACC18-0051(Best View).docx I MAP SHOWING BOUNDARY, TOPOGRAPHIC & TREE SURVEY OF: ��gl/I'L LOT 3, MILBERT HOMES SUBDIVISION, AS RECORDED IN PLAT BOOK 21 , PAGE 38 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA IN SECTION 16, TOWNSHIP 2 SOUTH, RANGE 29 EAST OF SAID COUNTY. / Li LOT I CERTIFIED TO: ol, --� � } -� �S S- L JWB REAL ESTATE CAPITAL • LINVILLE F. YOUNG oXll•65 a{(4„:(4,„,,, � ��• 384 3RD STREET MILBERT HOMES SUBDIVISION (r Q ATLANTIC BEACH, FL 32233 PLAT BOOK 21, PAGE 39 ;3, f1((_ RE ID. 169800-0000 ORB 585, PAGE 508 11./0 S 10°256 45(P E 00_____ yYBI ' . 9 DISK 'AFND IL A 4 223 f FOUND 1/21P, NO 60• W.75 m'. CAP (UNDER FENCE) _ t,6 p�STIC fir" m t1E:0• N 1 E 3 ' 1 FENCE ON-LINE a % -cZ, - SOY(/' FE 1 12.16 24.OAK IT. F-3 ;-”r" a // 70619.t" ♦ i•AL 4 S w m Z r•-, u' Lt�`l t( a40. 1 F, .. O � 12.2' n P u1 6p'BSL DECK 12.3 vQccyY . Sr LOT 1 7.5' 14.2' No 31.0' n mo=n .t: LOT 3 12.1': z mmz .oz z 3.5' A/C PAD LEANT T- -Z,.. f UNITS ow `. co z� •� 2 STORY WOOD FRAME '' •'o N.-mm . _p0 m BCEL 5 LLC •A • ON /2.00 coo=.- C.) LOT 2 o °c: my 275 SHERRY DRIVE N O aw• o= :J ro > to ATLANTIC BEACH, FL 32233 • ^0 m -n z 0 RE ID. 6ro 9O "N y m o )eO o t ORB (77439PAGE2009 000 o 4.4 61 1+' o - rte'., `1 FINISHEO FLOOR ELEVATION 12.80' Q, FENCE TIE: W" a o p - -or"_ m 3•X3• r" 0.5'N A z ^ ;._,;_..:,, PATIO a mmx,,,r, J v n 11.0 2.7' A - Nnc.,Ori to o 0 0 7.5' m• w FENCE TIE: 4 p® l b '- nu) o- 0.1'S 20. 8.3 : I1 o- o 1 DENIED a o- rn 16"PALM 7.5' 112.0 1.+'orT-�� 11 It''t10'PA M11.39 _ -c-.. o N N 12.221: 16.3' �.BSL`----wJ o,-, • ° W 11 2 - 12:09 N z3 '" 1 m 18.64(W 7, 10 P.27 L.j 12.08! GRAVEL, 11 : • •• 1 1'> 21"CEDARP (0.95 60.g FENCE TIE: 0.1-N FFPALN 11.54 ,11.1 +ter T...--- -073 26"CED k CONC. DRIVE i MI f �'m1 FOUNDMXCUT 1 gyl�2_' ASM 11.43 g.iP1E 'wALK",' ONE EL. 10.49' W 60.3_.---,-_-•-.--ONE •RISER SET I/2'REBAR • 1F,1MOO ;; N 12.50•00'''8,-------- 50 0_- GRASS 969 OR959 WE & CAP 'LB 3604' 70.46' OHE 1211/PP WITH 8.83 �Jr 16.3' �r DOLLY TRANS.,UGE_4 64 LEGEND: 0---11--- - OHE BAcK OFrRB CLF CHAIN LINK FENCE 9,60 L19.61 CONC 8,... EDG- piEMENT ASPHALT •CONC. CONCRETE TELE.RISER E OF EL. ELEVATION GRASS L LOT 3 PLAN 2500 LEFT FL FLORIDA _ 8.48 IP IRON PIPE 8.56 -�- ASPHALT DRI NIE LOT SIZE 6,3461 S.F. IRC IRON ROD AND CAPRB OFFICIALOVERHEAD L ELECTRIC EC RDSCBOOKE 8.36 Opo t60. 0 H11 w ey F C pT 1 ST FLOORAY TLIVNG 1RAY 96681 S.F. FRONT ENTRY 551 S.F. RE ID REAL ESTATE IDENTIFICATION NUMBER 1(/W RIGHT-OF-WAY FRONT WALK 461 S.F. TELE. TELEPHONE A/C PAD 211 S.F. TRANS. TRANSFORMER SIDE PATIO 9t SF. UGE UNDERGROUND ELECTRIC LINES WBF WOOD BOARD FENCE GARAGE 4071 S.F WPP WOOD POWER POLE TOTAL IMPERVIOUS AREA 2,801± Si 44% NOTES: I. BEARINGS SHOWN HEREON BASED ON THE PLAT OF MILBERT HOMES SUBDIVISION, AS RECORDED IN PLAT BOOK 21. PAGE 38 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA WITH THE BEARING ON THE EASTERLY RICH]- OF-WAY LINE OF OLD SHERRY DRIVE BEING NORTH 12°50'00" WEST. 2. ELEVATIONS SHOWN HEREON BASED ON NORTH AMERICAN VERTICAL DATUM OF 1988 PER TRIMBLE VRS NETWORK WITH AN ORIGINATING BENCHMARK BEING A FOUND X-CUT IN CONCRETE WALK WITH AN ELEVATION OF 10.47 FEET (SHOWN HEREONI. 3. THIS PROPERTY APPEARS TO LIE IN FLOOD ZONE UNSHADED "X" WHICH IS AN AREA DETERMINED TO LIE OUTSIDE THE 0.28 ANNUAL CHANCE FLOODPLAIN, ACCORDING TO COMMUNITY PANEL 120075-0409-H OF THE FLOOD INSURANCE RATE MAPS FOR THE CITY OF ATLANTIC BEACH, DUVAL COUNTY, FLORIDA, DATED JUNE 3, 2013 AS PUBLISHED BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY. 4. THIS SURVEY WAS PERFORMED WITHOUT THE BENEFIT OF A TITLE COMMITMENT. THERE MAY BE EASEMENTS AND/OR RESTRICTIONS RECORDED IN THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY FLORIDA AND NOT SHOWN HEREON. 5. THIS PROPERTY IS ZONED RESIDENTIAL SINGLE FAMILY IRS-2) WHICH PROVIDES THE FOLLOWING SETBACKS: FRONT: 20', SIDE: COMBINED 15' WITH 5' MINIMUM ON EITHER SIDE; REAR: 20' PER THE LAND DEVELOPMENT CODE FOR THE CITY OF JACKSONVILLE BEACH. 6. ALL LIVE OAKS AND LONG LEAF PINES ARE MARKED. ALL OTHER OAKS ARE SCRUB, WATER OR LAUREL. ALL OTHER PINES ARE SLASH OR POND. LEGEND: SCALE I"=20' UeatOT C'EM„fT 11A111ns5UeVEY MEETS„le 5,0N0Aanf UP . CJaI consultants ruc icv_Issn Mall CV mEP1.000*toAtn OF SUSVITOPS 1701 RIVer�;tee Boulevard Suite 900 ANDYAPPERS PUPSUANT TO UMAPrEt,n.2T OF THE notion Jack onvill"e fl ori du 32201 S,A,U nH AND 51,7 or rift,uoem)A, ,NlsrtAuTE COOP 904-63.11 I3 904-63-111 fFax) ,,{� www.ga,consu tanla.com JOB No. ,�)f \.rl .i' MrNO .FIJGR:nCAING•PLANNING•SIIRVI:VING•C795FR\'TITS 8160030 DATE JUNE 25.201g MgNI S%CEK FlAP 5 A CIX_NU.LS 6016 NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED PROFESSIONAL SURVEYOR AND MAPPFP.. 1rs1-IV�t�GBOLI�J�'TY,,/TOPOGRAPHIC ---,i.QT 3 PIE.ISM.1,, �� IVP & SUWE VE-. u E1/e3 SF. pRIL�RI,I tO RN ]Mi Sf LOT 3.VLLBERT;KIVU 5..8.,cDOw Ac RECO' PU'BOON 2- P.C,E •E'DF THE tUPRrw�pUB4C w2tSOJ OF OUVAL C:A , FL 5A) AN SEC Tipfl ib, 'S'FLOW UAIO 3 MtSUI 5 •oWNSNv 2 SOUTH.RAIrtIE Z9:AS,a sAq:JVN^' FRONT wow 7aesr MOYT silt STt SI LOT 1 ,r A/C PAO Mt J. ) LINN f g 7,10T:11,10 Nt SF 36CL L Sr MILBERT 1-014ES S*ii 2 SIGN n.+.) , RAno I1t sF A, ETEAEOC EALN 32133 m_AI BOON 2'.PACE 39 .9.. SET AIA MO O6N ON 1071 Siof1•tE9gm mphOF9]A`. Aa 5pR i% E •, iOP pF tFRQ vpST `"'-'"• 5'•216(Pl ��1' `ME I NPEMAWS ARA 1152 SI Al2 4.: 10)9I�1FN0 �!'T—QF'1� I59w ai Fiwa) _� uilRE100M APPROVED Tole 1P, t ' 1 Y Mkt RE '. Pw �. �t LOr a ORAINAGF mow- 9 Ode () �[ {JJ� �.®����. i 1. THE COVERED PORCH AND STOOP SHALL BE wiY•/7H H!V/(1/! * 1 SLOPED AT MIN. 1%AWAY FROM STRUCTURE. AT THE ,A.o c ST a' I EurEE1 'v CONNECTION PONT OF THE PORCH AND STOOP,THE ON "'q., O 19,140v ►7 �Ir�« TYPICAL ELEVATION DROP SHALL BE 4 INCHES. O mow I LOT , I• _EsFO 2/f,�� 'c'-..-i.4.1.- g� 2. GROUND ELEV. AT FOUNDATION SHALL BE MIN. 61N h;i VI : :' 'i ih •El yQ) 9? £ BELOW F F. ELEV. _i LLL L07 2 R 17m YV$A Yr, 4 �/ :1 8 A�` •t!1 EnaVR _tp$ f 3. CITY OF ATLANTIC BEACH ORD. CODE SEC.24-66(8) ON Di%.• 0p`;; o © �� / • 1- ^A I' •'/• '" SITE RETENTION •_ gib i F. . i k�A I9 4. RETENTION AREA TO RETAIN 719cuft OF WATER FOR 25YR. �""•. '1.0• STORM INTENSITY OF 9.3 INCHES. ! $1 a:.W8s ° p.3' v-'o a'7 Flow, 5. RESIDENTIAL DRIVEWAY APRON SHALL BE 5" MIN. 4000ps: � -0.7 -Is • CONCRETE. I z -I it . LE0 U'�froIEN �� icIE\a ARG TQ F UW �• A. r6 man COX S 1 i I V iE•P•LlY - �Lya# Vim. 1 ,E OIT k" I m. I ,i 11120!, /} -• v� G I C �'._ p 6039 IP� DRAINAGE LEGEND a 9 w • PRE-FLOW ARROW PROPOSED SPOT EL. LS „�tr, I 25%‘03.: ,,,q R o�Tl • 1�1�- ���� , 1:'�01"�'`-L-' — PROPOSED SHALLOW SWALE r�"1p`-a' !bo bO. L—.'.. "AFP L oo QM POST-FL OW ARROW 1 I EL 10 W L W t6, pePe ,o aq'lP1 N L •SMO OL •-,lt •O Alrai '" EXIST. SPOT EL. / IEGENO. Ile6E El 1 P.YNOII Bim"Oi PA tf, -- • 1lir CLF C CNAA lE EIACE AA ]OA 4-(RAM PAAOIF ILLEp�RAp° A1 GRAPHIC SCALE MfW D�.PE NE WC PUN RCADp A�NO[�. ERRY DR I OpVFICT�L RECORDS BOON ,L. F� S ''s PPLS • � - - p Rfi(ALT 5T '''—OLD P, �' i��"N t B� B� t ./ E b RK.NICOFAM gCNTIf CATION NUMBER h is i. iFl Fp7, OF IRAN fOFMER •...." .. ( IN PFFE0 rm R(GRI L CCrRIC LINES 1 IMA - 20 I!r MMOOOUCC PB PEONLECC SL Cr Building Permit Application Updated 12/8/17 A '2 City of Atlantic Beach Viair 800 Seminole Road,Atlantic Beach,FL 32233 hone:(94•)2, 58 6 Fa (904)247-5845 Job Address: 02? d-41 4-17,e--,6V-LP-Permit Number: C I 8 -00 Legal Description ' [ 3 elbal 2._- E in'Zte . RE# Valuation of Work(Replacement Cost $ /S deo Heated/Cooled SF Non-Heated/Cooled • Class of Work(Circle onedo, Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): CommercialResidential • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describ 'n detail the type of work to be performed: / s? �1 70.._riP� ?.t-Kb .fes zvdGl/ a r0i.�,�.; 74 7 6 ,,,te•� 1/4:7 Florida Product Approval# for multiple products use product approval form Pro s ert Owner Inform. ,,i n Name: ♦/` ( . / Q11; lce, Address: 7� e1"!''J P..- City 'City i c r ' State /- Zip 2:1 3 Phone '403- 278 ys12_, E-Mail ?vi' rigfis. .y- cq i.--.- 1411-"P ColncezJ' - Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Informaw ,/ `, `_� Name of Company: -�We 1 a' e'-�' &Qualifying. ent: CI " 544,-- Address TS2the✓i /(e c'f - City J( State f' – Zip .�2Z/A) Office Phone 10K--- 22e--2,.2/ Job Site/Cont m(aer y0. 'J.-24'— aia- State Certification/Registration# E-Mailv L= • e/` •►r: :ca h'tc /- Architect Name&Phone# Engineer's Name&Phone# Workers Compensation )( •gyp t 6 2- 2c2c7 ! Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS, etc. NOTICE:In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR OTICE OF COMMENCEMENT. :\_alf,...._ PP ( 4j '' (Signature of Owner or Agent) (Signature of Contractor) (including contractor) Signeol and sworn to(gr affirmed)before me this 7? aylof Si ed 2worn to(or affirmed) to m day of by t'''\ Nci\\ `C/ i t' e► -, a-0 At by 12: ',Cs. .1ke.; Pmei If !Pia", 4 la4.Nopr 11-411Si:nature o rY) -..- :4:I.'''.• ' JAMIE D.SMITH T [ ]P Wally Know ej � :.- MYCC�IMISSION#GG 255331 [ ]PersonallyKnl.v. JAMIED.SAMITH roduced Identifi �a ►,;4 EXPIRES:September 5,2022 F�lr r.,y�,P XOOMMIsepte tGG25533• roduced Ides' � �*; �� EXPIRE3.� to Type of Identificatio "�f•f•'�A Bonded Thal NotaryPubI Unde un Type of Identific.'�ioh`PRn° Bmde p mber5,20,, Thrn-+ aryPublic Lind •:. E JS , CEI , F ATLANTIC BEACH - - S) NOV 1 5 2018 800 Seminole Road r tlantic Beach,Florida 32233 leo; BY. REVISION REQUEST/ CORRECTIONS TO PLAN REVIEW COMMENTS Date //`r/1(-4 Revision to Issued Permit Corrections to Comments Permit# NCe_kg-005 Project Address (-2.2i siri ,)r C� '"'"`�/G `fie,c`'''� 1'` 2 -233 Contractor/Contact Name ( Wei �re' r CeAiE/4 Phone `7D(i-- 226 222-1 Email et[4(4(/�'rh VOcome411stel- Description of Proposed Revision/Corrections: Permit Fee Due $ / c /(. ec Q.r'{-^J' 7''o e,v(o J' / c%/ e'd' 644,1_4,-/:...,5 �^ Z r� e�c eti Q he �� Elie'" . • -Cl`tger.Q /yi.L re etee /6 7D/'`OCect&'-e1 e?4-(C4-C<4J,, '� eli''c�jeK,r / ,,-z 'i,&^i/1 4,y kfee f' ti/ Additional Increase in Building Value $ Additional S.F. By signing below,I affirm the Revision is inclusive of the proposed changes. (printed name) Signature of Contractor/Agent(Contractor must sign if increase in valuation) Date (Office Use Only) Approved V Denied Not Applicable to Department Revision/Plan Review Comments 4,,,x- die fi ®; /G yr /ter4„ irg-- De'a ii -nt Review Required: au. ...e,_ i4áZ Planning &Zoning Reviewed By Tree Admmis r. . blic Works /( /, / ' Public Utilities Public Safety llat Fire Services / P)79J �� L -?p70-/ o A-r-ivw-yv di-Y -6Y°72,S) tz4d, ' 7/7 ' lJ e __?/„,ry 0/ £1 )pry yi,) - #72.-J-21wo?S' 772h ��� 72z, oma gacQ c, c > r(2171-(!? '11,2-1 Gf _1/9 •'1/'x/1'7'/-6 moiJG „,' , 4C<J'yi- 6 �� 727, -75 -?-.(<7 'y'/972 j G5 ” 6 -4 )Z 1/ )5"-S eo -›/a -..c��. r f -> a yav /o( J o if? Comp. By: S/W Date: 10/29/2018 13141,01 Js Public Works Department City of Atlantic Beach Permit No: PooI18-0004 Address: 275 Sherry Drive Required Storage Volume Criteria: Section 24-66 of the City of Atlantic Beach's Zoning, Subdivsion, and Land Development Regulations requires that the difference between the pre-and postdevelopment volume of stormwawter runoff be stored on site. Volume of Runoff is defined as follows: V=CAR/12 Where: V=Volume of Runoff C =Coefficient of Runoff A=Area of lot in square feet R=25-yr/24-hr rainfall depth (9.3-inches for Atlantic Beach) Predevelopment Runoff Volume: Lot Area (A) = 6,345 ft2 Runoff Coefficient Area Lot Area Description (ft2) (ft2) "C" Wtd "C" Impervious 2,138 6,345 1.00 0.34 Pervious 4,207 6,345 0.20 0.13 Runoff Coefficient(C)= 0.47 Runoff Volume V= 0.47 x 6,345 x 9.3 / 12 V= 2,309 ft3 Postdevelopment Runoff Volume: Lot Area(A) = 6,345 ft2 Runoff Coefficient Area Lot Area Description (ft) (ft2) "C" Wtd "C" Impervious 3,172 6,345 1.00 0.50 %ISA= 50.0% Pervious 3,173 6,345 0.20 0.10 Runoff Coefficient(C)= 0.60 Runoff Volume V= 0.60 x 6,345 x 9.3 / 12 V= 2,950 ft3 Required Storage Volume DV= Postdevelopment Runoff Volume-Predevelopment Runoff Volume DV= 2,950 - 2,309 DV= 641 ft3 Retention Sherry Drive 275 extra pavers 10/29/2018 .22 2 ,3! Comp. By: SIW Date: 10/29/2018 r �v 40169- Public Works Department City of Atlantic Beach Permit No: Poo118-0004 Address: 275 Sherry Drive Provided Storage: Elevation Area Storage (ft) (ft2) (ft3) 9.2 0 BOTTOM size 46X 2 10.0 276 110 TOB size 46 X 6 Elevation Area Storage (ft) (ft2) (ft3) 9.5 0 0 BOTTOM 10.0 100 25 TOB 10 X 10 Elevation Area Storage (ft) (ft2) (ft3) 0.0 0 0 BOTTOM 0.0 0 0 TOB Ing round storage=A*d*pf A=Area= 376.0 d= depth to ESHWT= 6.0 pf=pore factor= 0.3 Ing round Storage= 676.8 ft3 Required Treatment Volume= 641 ft3 Supplied Treatment Volume= 787 ft3 Retention Sherry Drive 275 extra payers 10/29/2018 or.14,7 .40fge •=i4f-.Wil Ld- /00 6.0 lo/e \ by ,T12 Id/ i(7'17X) 4„e leX --7 -4'z:› ,ged Avt44 Vof 13/ it KV -,4c ,ej71 `; 1 -22 IC fi7V Yier z lb vj 141506 _.01124_ izzt,„ sezie oe0/ czyw ,t,cki fifty (, /A) APPROVED 6 `(MAPSHO NG BOUNDARY,TOPX AA-Is 7 AaD �,&TREE SURvEYOF. LSW 6 If LOl.I.W19ERT MOUES 5JBD�N5.CS. AS RECORDED IN PLAT 9OON 2' PAGE 58 OF 741 '57 FLOOR 1I IC 1669MAI SF CJRREN,PUBIC RECORDS OF DUVAL COUNT T.FLORIDA IN SECRd,16. 'S�itODi 11Y91C 1666!SF '0904SNV 2 500112.RANGE 29 EAST OF SAID CO,19'Y 'R01 IS TRT is 5 FRIf LOT i A/5 RAO +E1S.E LAIN 1 90.9W j SCE PA IID IES S,. 56a R2 S MILBERT HOMES SUBDIVISION 8, tt.6) f SAO1049 FARO :39j SI I Ft:.1NP.0 169)0 0225! PJi BCXRa 2'.PACT 59 '- SET NAR ARD 069 ON t RED t6990L'-0000 ) j,OP IX FERCI POST GARag a42�Sf ORS Sfl9.-AIX 506 1 0206` 6� '/0180 K'fANR.S ARCA 29782 S r.ats ' fI_ ,' FaAo t/7Y SC T oD;gam AP(*OCR Cl.,i[i i RE1E 1901,MRA .YBF T���l 8971 CRT 080[ !AZ; 9018 196 1■L i • I RI RVQ tli ]i�� 1 €1`n_A ��• ,• .-- i PORCH AND STOOP SHALL BE oosN 11��� {` SLOPED AT MIN. 1X AWAY FROM STRUCTURE. AT THE .."""""'vq SPOUT ILI I 14.0 31 C Ind z G CONNECTION POINT OF THE PORCH AND STOOP,THE ,^°'•ON r7 inv. TYPICAL ELEVATION DROP SHALL BE 4 INCHES. }� �.... I 'I 4->0.f, 2. GROUND ELEV. AT FOUNDATION SHALL BE MIN. 61N /fq W 4 i z _' /�, ym 9 E BELOW F.F. ELEV. 4 j.T.) P' ,OT L A l'2 W) 1`4 y• Q < 1 8 A , 2 7 -9�Ft?E 1R. 4N L1 3. CITY OF ATLANTIC BEACH ORD. CODE SEC.24-66(B) ON 4 d"' d!3' Fes,•o 8{= A°- 1'!7 �!9 SITE RETENTION 6,9'•.•..� • J F 9I$ ':61 -I� I� 4. RETENTION AREA TO RETAIN 719cuft OF WATER FOR 25YR. �'Ww....." �Fy c o`r� , STORM INTENSITY OF 9.3 INCHES. -1 ,-.58.1., .o J U n.D. '-I" r $i a1;,IR5�= II I 20.7 �--•c -'1.• Dowd 5. RESIDENTIAL DRIVEWAY APRON SHALL BE 5' MIN. 4000psi 'f Y • CONCRETE. ]' 16D �2.,1 .• ) g OOl 12 ii "I 2 6 16"PAC M '1 t I R76NNllP/NRAPet ¢ z (0 1 at { I'• _ v I�As-4,-.:, { arr as W g S { /ID n R Oat i� 181P41, l�•� 1 t n N mN I • PiOvpSE.,�� E0.59'TIP� DRAINAGE LEGEND r w OW .. �. ACDF^- AIM- PRE-FLOW ARROW PROPOSED SPOT EL u t 3 2E"CEpep ....1:1111, OPCR'�:.;:Fir. N :'nct rc 2& hu5) � , .::. 0191D x-:,1 —-— PROPOSED SHALLOW SWALE -44-4 I FCUIC 9-CO' is 6D ,I 10.1 G'� POST-FLOW ARROW 10 49' (I (vl + N I " •,6� ,, (97' EXIST. SPOT EL sotoe )11. TI011 ' .• 6�E.c 1 F i ji oI ASSIMOS IEGENC 6� Ped:' 6rf.T 1• w. - C1�C ,&Opp1 K FENCE /6'pCA R Tf PN' J66 ST-GPAK.#894445 1 FC ON ROD AP tR MI �p pR{� GRAPHIC SCALE I OVERNEAO SRIC INE OLD y{EIN•`p1,A11 . Con sulton;s = ., f ORE LY fALT Al DSII CA "-(6C•R'~8Nistmeof MC iii v �N n...��..+„ � l' (RPE`IO CRLEAL ESTAlE DENitf'CAlICR1 NUMBER 01 II R RIGHT- -WAY j E,,,VE.EPNON4EE I IN FEET) 9 i,N- TRe(SfORM I Fr Am 9_ ,15E UWOCC 60MFR [ lE1RiC LINES 1 i N 20 1t ! W�F fPEONLr WALL BLOCKS '.TONEGATE . 0 PRODUCT X DIMENSIONS HEIGHT DEPTH SF PER CUBE CUBE WEIGHT I illr . RW03150 SM:6"/4",MED:12"/10",LG:16"/14" 6" 10" 26 2500 LBS UNIVERSAL CAP PRODUCT X WIDTH THICK DEPTH UNITS PER CUBE CUBE WEIGHT I RW03180 10" 2-3/4" 12" 120 3000 LBS COUNTRY MANOR 6" IP PRODUCT X WIDTH HEIGHT DEPTH UNITS PER CUBE CUBE WEIGHT ' RW03147 6"/4" 6" 10" 128 2750 LBS COUNTRY MANOR 16" PRODUCT X WIDTH HEIGHT DEPTH UNITS PER CUBE CUBE WEIGHT RW03148 16"/14" 6" 10" 48 3000 LBS COUNTRY MANOR CAP 9 PRODUCT X WIDTH THICK DEPTH UNITS PER CUBE CUBE WEIGHT R W 03149 70"/12" 3" 11" 96 2500 LBS II rilk • • vr� 1-E + / r 7:-;--1: / s it r L�q,�J 1 14 ''..''''' I , *'.7111 .-,.. ...,-;4;`,.,7' ' f �.. \� f °4,.n `"V M i kv.e` a 4 x: _ _ yew- '-r.'•'-',.. ••4:. V' A • t r y - : - .. _ r �_� �__ , y �:r,- is -— 1 , r- _4 4.>.' - �a ,; - ''iA, 4. 11 "sem . it _\ nub a 1 _r � • ' �F. • ,J - , ., s;... ear, -zit a 1. 444 \ r (� ` MN BL!+. _ p'Lit `r 4X8 PERMEABLE AQUA PAVER SF RIMA S III 00* .- Milry 63 TURF BLOCK . - OWNE PERVIOUS 4X8 PERVIOUS 1 ., a el /. .. :,.. i i • 7 ...fix. y _ 1', \ •r• s,,, .--'!-,.''.7`;:::"' 'mss;.. • - 1:*411111111(':. ' 1:17.4."*-- - 7 - • :-:1- --- --- -".. • _ •... .„. _ _ - _ •.- .•• -",. - . -,- • - - - _ - � . • 4 Y A • • A P r s v e y A • '( r r -.4 �- r '' A 1. .. fir• 1-. r H .t 5 I -5 - 1 - - M - ••I t c. • • � c _,fir ..J. i GREF \ COLLFCTIO \ Tremron's Green Collection offer an eco-friendly option while protecting and maintaining the integrity of your landscape design. These specially designed pavers will reduce or eliminate storm water runoff and decrease flooding,which relieves sewer systems. In addition, Permeable Pavers also provide a sturdy pavement for vehicular traffic and can be used in a variety of applications, from fire routes and parking areas, to residential applications such as driveways and patios. Choose from Tremron's wide array of easy—to-install eco-friendly green products.