646 SELVA LAKES CIR - SIDING RESIDENTIAL PERMIT PERMIT NUMBER
f ` ` CITY OF ATLANTIC BEACH RES18-0371
u
800 SEMINOLE ROAD ISSUED: 11/19/2018
rs3` ATLANTIC BEACH. FL 32233 EXPIRES: 5/18/2019
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property
that may be found in the public records of this county,and there may be additional permits required from other
governmental entities such as water management districts,state agencies,or federal agencies.
JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK:
646 SELVA LAKES CIR RESIDENTIAL ALTERATION NEW T1-11 SIDING $8000.00
RESIDENTIAL
TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION:
CONSTRUCTION: NUMBER: GROUP:
172027 5802 SELVA LAKES UNIT 03
COMPANY: ADDRESS: CITY: STATE: ZIP:
SUPER SIDERS AND TRIM, 65 W. 9th Street Atlantic Beach FL 32233
INC
OWNER: ADDRESS: CITY: STATE: ZIP:
STEWART IAN STEWART 646 SELVA LAKES CIR ATLANTIC BEACH FL 32233-4377
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 455-0000-322-1000 0 $95.00
BUILDING PLAN CHECK 455-0000-322-1001 0 $47.50
STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.14
STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00
TOTAL: $146.64
Issued Date: 11/19/2018 1 of 2
OFFICE rOP
Approved g Pe
NOTICE OF COMMENCEMENT y /foil Desk
(PREPARE IN DUPLICATE) Building Department
�S��— 3 7/ / City of Atlantic Beach, FL
Permit No. Tax Folio No. �nA
State of Lc)r-r��e4 County of kO ✓C/
To whom it may concern:
The undersigned hereby informs you that improvements will be made to certain real property,and in
accordance with Section 713 of the Florida Statutes,the following information is stated In this NOTICE OF
COMMENCEMENT. l/k //
/ `.�
Legal description of property being improved: �/
`,4 :,5 v/,12r 3
Address of property being improved: U/�� �� �a �( /e /
General description of improvements: lute &C) 541�C� G )/
Owner a{'d tY-/ _ 5- Ge/GlAddress CSi`t6 .5(�l ✓a /LI'S/ c/
Owner's interest in site of the improvement
Fee Simple Titleholder(if other than owner)
Name
Address
Ai '/ Contractor 51,11 S,G)7 ef� CiYt I l td/l.
f p I\ Address r'Z ) iCC(1.r1 � L� T /%i C .
?u^ A)J Phone No. / 2/ � Fax No.
Surety(if any)
Address Amount of bond$
Phone No. Fax No.
Name and address of any person making a loan for the construction of the improvements.
Name
Address
Phone No. Fax No.
Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other
documents may be served:
Name
Address
Phone No. Fax No.
In addition to himself,owner designates the following person to receive a copy of the Lienor's Notice as provided in
Section 713.06(2)(b),Florida Statutes.(Fill in at Owner's option).
Name
Address
Phone No. Fax No.
Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a
different date is specified):
THIS SPACE FOR RECORDER'S USE ONLY NER
Signed: DATE /� '�/atd
Before me this day of >�kid_ i the
Doc#2018271959,OR B K 18600 Page 2000, Courcy �w 5(a�,or Florida•has q�sonaly appeared
fX l�y-g WAST hereto by
Number Pages:1 himself/ erself and affirms that all statements end declarations herein p�
Recorded 11/19/2018 09:29 AM, are true and accurate
RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL
COUNTY ...... STACY MORRIS
RECORDING $10.00 :'�
,.s = lira : 797
Nota 'Pu'rc at Large,State of - • 1,771 • law gsmarek.237.2019
S: :i��o? ,-"1.Personally Kno ,..,;° :.n.•' lu r°y an=once?"`'.57019
Producedl entifiication -
S .AN-fir, City of Atlantic Beach APPLICATION NUMBER
�S + t, Building Department (To be assigned by the Building Department.)
r `--,i 800 Seminole Road
R ES( c-�
J-a ,. Atlantic Beach, Florida 32233-5445 —L/�
Phone(904)247-5826 • Fax(904)247-5845
�J,319r E-mail: building-dept@coab.us Date routed: 1 t 8
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: 6.4 C C
S Q.4--1/A- t<LiCç Department review required Yes o
qilding� V
Applicant: gOP Ea—S t De S 12t/Y1 tanning &Zoning
Tree Administrator
Project: Ti l l ._ ( r ( Public Works
Public Utilities
Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: 1 Approved. Denied. ❑Not applicable
(Circle one.) Comments: /1 r ei r., a cora d- 11/06._ v t Pe c -d+�,
:UILDING ,V Y /
PLANNING & ZONING Reviewed by: Date:/I'/41
TREE ADMIN. Second Review: Approved as revised. Denied.
pp Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: Approved as revised. I (Denied. I (Not applicable
C• omments:
•
Reviewed by: Date:
Revised 05/19/2017
`•ii Building Permit Application Updated l2/8/17
,.a City of Atlantic Beach
800 Seminole Road,Atlantic Beach,FL 32233/ Phone:(904)247-5826 Fax:(904)247-5845 R E.S t - (--) 7
//
Job Address: l 2L // Se I UCL I Gc.ke C; N . Permit Number: -
Legal Description Ei,Y2 ,�. a,t 1 3 10 — RE# I 7Z-0i7-500 a
Valuation of Work(Replacement Cost)$ Heated/Cooled SF Non-Heated/Cooled
• Class of Work(Circle one): New Addition 'teration 'epair Move Demo Pool Window/Door
• Use of existing/proposed structure(s)(Circle one): Commercial Residential
• If an existing structure, is a fire sprinkler system installed?(Circle one): Yes 4roN/A
• Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removale_ec( r16 /5 /
Describ�detail the typ'eQof�/k t�o.be perf�dC:� /zJ" ql�li I�`C",Q��lG� GrJ�7A-
Florida Product Approval# for multiple products use product approval form
Pro @ ert Owner Information
Name:
/ / �// / f� l /�
Name: .11-X.air ' �Ceyf/e S G'G 7` Address: (O 4 5�` /aZes- L / 1/7
City ,v t i ,4 State iC� Zip ,TZz3? Phone qvL/ .3'73 /777
E-Mail -,-leis l _r-9--- I. -.,74 r (zyp . < i--L-7
Owner or Agent(If Agent, Power o Attorney or Agencytt6r Required)
Contractor Information 771e
Name of Company: `'�LtiOe — 5.--, C[/r{l •"—Qualifyin Agent: �l,-C-7 A vt'C�
Address e 7 ic4iiiJv� e,P -5!,'el T ;U/`, Cit State L Zi
Office Phone 0l7- 4/2e., 5 Job Site/Contact Number d
State Certification/Registration# '/IS 2� E-Mail j.eteil/17 G7 s-.17,4 d��/4°1Y.0A:1171/2i:4 . co,
Architect Name& Phone# 1
Engineer's Name&Phone#
Workers Compensation Si,i Pt-Z : 15 Lu f' 7vt c'e° /'C//?
Exempt/Insurer/Lease ployees/Expiration Date
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws julationg
construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBINOSIGNS, N
WELLS, POOLS, FURNACES, BOILERS,HEATERS,TANKS, and AIR CONDITIONERS,etc. NOTICE: In addition to the requirents of tidy
permit,there may be additional restrictions applicable to this property that may be found in the public records of this ,avi
there may be additional permits required from other governmental entities such as water management districts,state age i
federal agencies. 2 LU ES
On ~ 8 o
OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in complianc6.�vi�l
applicable laws regulating construction and zoning. w P. Q p
oZ � z
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT�1 Y N
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TOY• • ' : • 'ERTY. IF YOU�V �I
IA
TO OBTAIN FINANCING, CONSULT WITH YOUR LEND . •R ANA •RNEY BEFORE LL LL' Q 2
0 O w W
RECORDING YOUR NOTICE OF COMMENCEMENT110. .....(..16. c.......... .._____ . w >. a 5 m
�' wo w
wUcnw
CC w
k (Signature of Owner or Agent) (Signature of Contractor ++ W
(including contractor) ACCit
Signed and sworn to(or affirmed) before me this I day of Signed and sworn to(or affir before me this L day of
00./eimier , 2_01 4 ,by ' Sit WO - I- (,\O\/ , 1S' , by _ N. 'YY T
, i 411
l4N�lr1R�• _.
('Slg''q turg..CtigtfORPIS (S•:' ,n `. 't' Ission#FF 925374
.: Commission#FF 212797 hid
-�` Expires February 7,2020
ersonally Known OR e Expires March 23,2019 [ ]Personally Known OR Vie;^° o.�.4.,, Troy Fr �s,, .9ooxs7cu
u���..` Banded?nru Tmy Frn Inwu.rre NO-M-7019] P`P6.roduced Identification ",::,:!i::;;;-!:,''
Produced Identification , -�-
Type of Identification: Type of Identification: ✓ �d
+te r` C S,devv OFFICE COPY
GP Georgia-Pacific P I y w o 0 d
Plytanium® Plywood Siding
with a Primer/Sealer.
f` i` Introducing plywood siding
with a primer/sealer to provide
1111160.
added weather protection
_ ° • Primer/sealer provides
added weather protection
for the siding during normal
construction cycles'
„ . • Uniform base for painting
a
4 - • Pre-primed saves time
iF ..1 s 1 '.. * for coating and finishing
r applications
• Edge coated to reduce
water penetration and swell
t
at panel edges
' • Meets APA certification for
quality and performance
standards
•
Y
.., .. tt,GeorgiaPacific
PLYTANIUMAt
PLYWOOD
r
"
r
'Approximately four weeks of normal exposed
construction cycle
Plytanium® Plywood Siding with a Primer/Sealer
Georgia-Pacific Plytanium siding with a primer/sealer comes in a wide variety (a)Recommendations apply to all species groups for veneered APA Rated Siding,including
of attractive groove patterns and face textures,for both exterior and interior APA 303 Siding.
use.Plytanium siding is one of the most widely used siding materials because of (b)If panel siding is applied over foam insulation sheathing,use next regular nail size.Use
its appealing real wood look,its ease of installation and its toughness.It is also non-staining box nails for siding installed over foam insulation sheathing.
used for interior paneling,fencing and soffits. (c)Hot-dipped or hot-tumbled galvanized steel nails are recommended for most siding appli-
Plytanium siding with a primer/sealer is available from Georgia-Pacific in face cations.For best performance,stainless steel or aluminum nails should be considered.
grade classifications of APA 303-6-S/W, The face grade classification and span NOTE:Galvanized fasteners may react under wet conditions with the natural extractives
rating are indicated on the grade back stamp.Easy to install 4'x8'panels are of some wood species and may cause staining if left unfinished.
available in 11/32;15/32;and 19/32w thickness-AU Plytanium siding from (d)For braced wall section with 11/32 or 3/8"panel siding applied horizontally over studs 24"
Georgia-Pacific is rated with an exterior exposure durability classification. o.c.,space nails 3'o.c.along panel edges.
(e)Where wind velocities exceed 80 mph,nails attaching siding to intermediate studs within
Installation Instructions
10%of the width of the narrow side from wall corners shall be spaced 6'o.c.
Care and Preparation ' FinishingInstructions
Plywood should be stored and
handled with care to avoid �� Edge Sealing
damage before installing and �� Moisture enters the end grain of plywood or other wood-based products faster
finishing.Storage in a cool,dry • �� than through the surface.Consequently,edges and ends of plywood siding
place out of direct sunlight and .` panels should be coated.Although edge coatings are not necessarily moisture-
weather is best.If stored outdoors, N` A„ proof or permanently durable,they help to minimize sudden changes in
place the stack on a plastic ground sheet �� 11' moisture content in the siding,due to weather
and cover the stack loosely with plastic �l Edge• coatingis easiest to accomplish while thepanels are in a stack.Edges or
sheets or tarps.Anchor the coveringat the to Stretchck andlse over P g
P stack secure, ends cut during construction should be recoated.Siding panels to be finished
of the stack,but keep it open Film should be placed with a solid color stain can be coated with a liberal application of the same
and away from the sides and bottom to assure on ground under solid color stain or paint.If the siding is to be painted,use the same paint
good air circulation Stack panels on a level plat- stack as well. that will be used on the panel surface.Horizontal edges,particularly lower
form or on equal height bolsters or stringers which drip edges of siding,should be given special care because of their greater
hold the panels off the ground.Use at least three full-width supports wetting exposure.
along the eight-foot length of the stack—one centered and the other
12 to 16 inches from each end. Surface Preparation
Stud Spacing Proper surface preparation is a must to assure optimum performance of finishes
on any surface.Remove dirt and loose wood fibers with a stiff non-metallic
The maximum recommended stud spacing(span rating)for application bristle brush.Mildew may be removed with a solution of 1/4 part household
direct to studs or over non-structural sheathing is included in the grade bleach to 3/4 part warm water Be sure to rinse thoroughly with clean water
stamp on the panel back.The span rating also applies to the spacing of after the application of the bleach solution.Allow to dry before proceeding
the vertical rows of fasteners when panels are installed over structural with finish application.
sheathing appropriate for nail base. Finishes should be applied within 30 days after installation of the siding.
No diagonal wall Building paper Apply finishes during favorable weather conditions.Finishes should not be
requiredrecommended appliedtemperatureexpecteddrop
bracing when the outside air is to below 50°F
with panel siding - behind siding (10°C)within 24 hours for latex finishes,or 40°F(5°C)for oil basedfinishes.
Caulk around Always follow the finish manufacturer's recommendations.Wood surfaces
APA RATED SIDING - windows and doors should be clean and dry,although extremely dry surfaces should be dampened
Panels.All edges slightly when applying latex finishes.See the finish manufacturer's instructions
supported by framing
or blocking _ ..6"minimum for details.
clearance, Use only top quality finishes and equipment.Finishes should be applied accord-
siding to grade ing to the spread rates recommended by manufacturer Textured surfaces typi-
/g'spacing is recommend- • call requirehigherspread rates than smooth surfaces.The first coat should be
ed at all edge and end joints Y P
applied by brush.If spray equipment is used to apply the finish,then the finish
should be either back-brushed or back-rolled while it is still wet.Subsequent
Building Paper/House Wrap coats of finish may be applied by any conventional means.
Building paper may not be required by model building codes but is Finish Types
recommended when panels are installed over sheathing or direct to studs Two finish systems are recommended for use on Georgia-Pacific rated plywood
with shiplapped,caulked,flashed or batten covered joints. panel sidings:minimum one coat of opaque(solid colors)stains or acrylic latex
Panel Joints topcoat paint systems.Two coats are recommended for best weathering per-
All panel edges must be backed by solid lumber framing or blocking.Space formance.Semi-transparent stains should not be used on these siding grades.
panel edges 1/g"to allow for slight expansion and contraction as weather Opaque(solid color)Stains
changes.Panels are sized for this spacing.Georgia-Pacific 15/32"and 19/32" One coat of a high-quality oil base or latex opaque stain obscures differences
panel siding with shiplapped eight-foot edges have a self-spacing feature built in color between synthetic or wood repairs and the surrounding wood.The
into the shiplap profile to facilitatesoacine.Vertical joints require no caulking wood grain is also muted with opaque stains but wood surface textures usually
if shiplapped,back tit ding paper or house tura.,•. red by battens. remain evident under such a finish.When in question,a brush-out test should
Horizontal joints should be flashed,shiplapped or overlapped.Cau• . . be performed on a representative sample to demonstrate the finished appear-
joints where panels intersect with inside and outside corner trim,window an. ante.Follow the stain manufacturer's recommendations for application to
door trim and vertical bu ...• - •.. allow for a 1" .rimed plywood sidings.
lap over .. . t e foundation wall,11/2"for covering the sero . s. .late Pa (acrylic latex)
a • .minimum 1"lap at horizontal joints if not butted and flashed. If paint i ed on textured plywood,an acrylic latex paint system composed
of at least o coat and topcoat should be applied.A paint finish tends to mask
Georgia-Pacific Siding Installation Table t.-textured s -re more than an opaque stain and obscures grain and color
differences.On th•other hand,a top quality 100%acrylic latex paint system
Max.Spacing of Studs Nail Sae Nail Spacing will provide a more.urable finish-Follow the topcoat manufacturer's recom-
or Vertical Rows of Nails (use box, (in), mendations for appli -tion to primed plywood sidings.
Siding Span over nail base(in.) casing or
Description Rating siding nails) Panel l teeneediabe Note:These installatio and finishing instructions are abbreviated and are not
(a) (in) Long Blastulae (bile) Edges Supporta intended to cover eve installation requirement.For more detailed information,
Vertical Horizontal refer to your local buil•ng code authority and the APA Engineered Wood
6d for siding Construction Guide Fo ,E3OR.This guide can be obtained from APA-The
303&Rated 16(1c. 16 24 1/2"thick Engineered Wood As-.ciation,P.O.Box 11700,Tacoma,WA 98411-01001
Siding Ext 24 o.c. 24 24 or less,8d for 6(d) 12(e) Telephone(253)565-'•I I.
thicker siding
Cre and .. a,."um plywood products are cedined by APA-The Engineered Wood Association. An EXPOSURE 1' ,is able to
wMstand limited exposu.. -is drinycautructgn.Al EXTERIOR panel a meant for interior or exterior applications and can•-.:maneney exposed GP Georgia-Pacific
to weather when Propedy star-., .+•and finished These products may s... mold growth if expo:. ••.'n conditions,including
moisture,dampness,condensation,humidity.we,. . _ - , mildew fu ..ere •.- .:- .•.i,decay,rot or similar conditions are
not manufacturing or product defects and Georgia-Pacific assumes no re••.+. •: ..i or such conditions,regardess of cause Like al buiding
products,proper storage.handing and irstateiios are the responsdxaty of the user.For further information about wood storage and handing i•fomatiw visit .
www.gpu
ptytarmcom elocal Georgia-Pacific Corporation 55 Park Place
Atlanta,GA 30303
PLYTANIUM and BUILD IT BETTER are registered trademarks of Georgia-Pacific Corporation.STURDi-FLOOR is a registered trademark of APA—
urri�� Durr
GP
1� LY Tib N 1 U M Specifications-Siding
PLYWOOD
Plytanium®plywood exterior siding is an exterior-grade panel that is ideal for siding applications from new home construction
and remodeling to do-ft-yourself projects.
Available Types&Sizes(Sized for 4'x 8')
Length (Minimum) 7'-117/8"(2.435 m)
Width (Minimum) 3'-117/8"(1.216 m)
Siding Types T1-11
Reverse Board&Batten(RB &B)
No Groove
Finish Rough sawn or scratch sand
Groove Spacing T1-11 —4"on-center or 8"on-center
RB&B—12"on-center
Building Code Performance Categories,Panel Thickness
• 11/32 CAT,0.328"(8.33 mm)
• 19/32 CAT,0.578"(14.68 mm)
Specifications
Length/Width Tolerance +0,-vie(+0,—1.6 mm),based on 4'or 8'value
Straightness Tolerance ±'/,8"(±1.6 mm)
Squareness Tolerance ±1/8"(±3.2 mm)
Primary Species Southern Yellow Pine
Testing Agency APA®-The Engineered Wood Association
Classification Exterior—Plywood suitable for repeated wetting and redrying or long-term exposure to
weather and other conditions of similar severity.
Code Fire Classification Class Ill or C
Flam developed index<450
Building Code Compliance PS 1-09
Other Information l
FORESTRY Certified Sourcing
IN
Forestry Certification Plytanium siding panels are made from Sustainable Forestry INITIATIVE www.sfiprogram.org
Initiative®(SFI®)certified responsible wood sources. SFI-00007
Formaldehyde Emission Plytanium siding panels contain no added urea formaldehyde resins.Emission levels for certified
PS 1 structural panels are exempt by the California Air Resources Board(CARB)in the Composite
Wood Air Toxic Control Measure(ATCM)and phenolic bonded structural panels are exempt from
testing or monitoring by HUD in the Manufactured Home Construction and Safety Standards.
OFFICE COPY
GP
p LY T'1 N I 1. 1 F\"l Specifications-Siding
PLYWOOD
Manufacturing Locations APA Mill Zip Harvest
Location Number Code Radius
Camden,TX 515 75934 90 miles
Corrigan,TX 516 75939 90 miles
Dudley, NC 348 28333 80 miles
Emporia,VA 230 23847 40 miles
Gurdon,AR 517 71743 60 miles
Madison, GA 404 30650 100 miles
Prosperity, SC 329 29127 80 miles
Taylorsville, MS 282 39168 50 miles
GP Georgia-Pacific •
Georgia-Pacific Wood Products
133 Peachtree St.,N.E. Plytanium and the Plytanium and Georgia-Pacific logos are trademarks owned by or licensed to
Atlanta,GA 30303 Georgia-Pacific Wood Products LLC- Sustainable Forestry Initiative,SFI,and the SFI logo are
f.�An,ne.Le n!C„ef�inal.ln Cn.nen,Inniefi.,e Inn