Loading...
1607 ATLANTIC BEACH DR - NEW HOME PERMIT r1'= RESIDENTIAL PERMIT PERMIT NUMBER re pk CITY OF ATLANTIC BEACH RES18-0372 rs «� 800 SEMINOLE ROAD ISSUED: 11/28/2018 .6spx ` EXPIRES: 5/27/2019 ATLANTIC BEACH. FL 32233 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 1607 ATLANTIC BEACH DR RESIDENTIAL NEW SINGLE $485026.65 FAMILY RESIDENCE TYPE OF REAL ESTATE BUILDING USE CONSTRUCTION: NUMBER: ZONING: GROUP: SUBDIVISION: 169505 1065 ATLANTIC BEACH COUNTRY CLUB UNIT 01 COMPANY: ADDRESS: CITY: STATE: ZIP: TOLL FL VI LIMITED PARTNERSHIP 250 GIBRALTAR RD HORSHAM PA 19044 OWNER: ADDRESS: CITY: STATE: ZIP: ATLANTIC BEACH 414 OLD HARD RD FLEMING ISLAND FL 32003 PARTNERS LLC WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS DRIVEWAY APRON INFORMATIONAL Notes: All concrete driveway aprons must be 5 inches thick,4000 psi,with fibermesh from edge of pavement to the property line. Reinforcing rods or mesh are not allowed in the right-of-way. Issued Date 11/28/2018 1 of 3 S' J`i, RESIDENTIAL PERMIT PERMIT NUMBER J`/"`- �'' CITY OF ATLANTIC BEACH RES18-0372 �., 800 SEMINOLE ROAD ISSUED: 11/28/2018 =' ATLANTIC BEACH. FL 32233 EXPIRES: 5/27/2019 2 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line(904-247 -5814)to request an Erosion and Sediment Control Inspection prior to start of construction. 3 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 4 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list(Advanced Disposal,Realco Recycling,Shapells,Inc.,Republic Services,Donovan Dumpsters, Phillips Containers). Container cannot be placed on City right-of-way. 5 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration,including sod,is required. 6 PUBLIC WORKS CONSTRUCTION SITE MANAGEMENT INFORMATIONAL Notes: Provide construction site management plan,including location of silt fence,dumpster,portable toilet. Right-of-Way Permit is required if using right- of-way for construction parking. 7 PUBLIC WORKS RUNOFF INFORMATIONAL Notes: All runoff must remain on-site. Cannot raise lot elevation. 8 PUBLIC WORKS MAXIMUM DRIVEWAY INFORMATIONAL Notes: Maximum driveway width within the City right-of-way is 20 feet. 9 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL Notes: Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed,call 247-5878. 10 PUBLIC UTILITIES METER BOX SEWER CLEAN OUT INFORMATIONAL Notes: Ensure all meter boxes,sewer cleanouts and valve covers are set to grade and visible. 11 PUBLIC UTILITIES RT1 SEWER CLEANOUT INFORMATIONAL Notes: A sewer cleanout must be installed at the property line. Cleanout must be covered with an RT1 concrete box with metal lid. Cleanout to be set to grade and visible. FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $1638.00 Issued Date: 11/28/2018 2 of 3 %S'`�'''''' RESIDENTIAL PERMIT PERMIT NUMBER r s ;fS RES18-0372 CITY OF ATLANTIC BEACH VI ISSUED: 11/28/2018 1 800 SEMINOLE ROAD I \rii 9...V ATLANTIC BEACH. FL 32233 EXPIRES: 5/27/2019 BUILDING PLAN CHECK 455-0000-322-1001 0 $819.00 CROSS CONNECTION 400-0000-343-3701 1 $50.00 PU REVIEW RESIDENTIAL BLDG 001-0000-329-1007 0 $50.00 PW REVIEW BUILDING MOD OR ROW 001-0000-329-1004 0 $25.00 PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00 SEWER SYSTEM DEVELOPMENT CHARGE 415-0000-324-0301 0.75 $4050.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $36.86 STATE DCA SURCHARGE 455-0000-208-0600 0 $24.57 WATER METER ONLY DOMESTIC 400-0000-343-3301 0 $185.00 WATER METER ONLY RECLAIM 400-0000-343-3301 0 $185.00 WATER SYSTEM DEVELOPMENT IMPACT CHARGE 415-0000-324-0301 0.75 $1140.00 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $50.00 TOTAL: $8,353.43 Issued Date: 11/28/2018 3 of 3 V1: Cityof Atlantic Beach Vis" fig, APPLICATION NUMBER ►', 1 Building Department (To be assigned by the Building Department.) 800 Seminole Road R E lJ 18 _ /`372 9 �� Atlantic Beach, Florida 32233-5445 Phone (904)247-5826 • Fax(904)247-5845 '°b01310 E-mail: building-dept@coab.us Date routed: I ( 1 1 (I/ S City web-site: http://www.coab.us ((( APPLICATION REVIEW AND TRACKING FORM Property Address: I I?07 mAcc.nk-i Y1 Department review required Ye9/'No Applicant: I 3�� YOS Planning &Zonin Tree Administrator Project: e t.0 Fublis rk)o Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPL ATION STATUS Reviewing Department First Review: Approved. I (Denied. Not applicable (Circle one.) Comments: ii)oc, BUILDING PLANNING &ZONING Reviewed by: Date:/1-1 ? /S)/ TREE ADMIN. Second Review: I A roved as revised. pp ❑De d. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: I 'Approved as revised. CI Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 ill!, F, t 4 2) Building Permit Application Updated 12/8/17 '' City of Atlantic Beach *'A_ 800 Seminole Road,Atlantic Beach,FL 32233 Phone:(904)247-5826 Fax:(904)247-5845 D Job Address: 1607 Atlantic Beach Drive Permit Number:IZe S I 0�j -O31 a. Legal Description Lot 2 Atlantic Beach Country Club Unit 2, Parcel#67-52 16-25-29E REN 169505-1065 Valuation of Work(Replacement Cost)$438123 Heated/Cooled SF 3761 Non-Heated/Cooled 1227 • Class of Work(Circle one): New Addition Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): Commercial Residential • If an existing structure,is a fire sprinkler system installed?(Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: New home construction Florida Product Approval#see attached for multiple products use product approval form Property Owner Information Name: Toll FL VI Limited Partnership Address: 160 Cape May Avenue City Ponte Vedra State FL Zip 32081 Phone 904-217-0739 E-Mail aregnier@tollbrothers.com Owner or Agent(If Agent,Power of Attorney or Agency Letter Required) Toll FL VI, LP Contractor Information Name of Company: Toll Bros., Inc Qualifying Agent: Steven R. Merten Address 160 Cape May Avenue City Ponte Vedra State FL Zip 32081 Office Phone 904-595-5243 Job Site/Contact Number 904-595-5243 State Certification/Registration U CGC1510225 E-Mail aregnieretollbrothers.com Architect Name&Phone ff Toll Architecture(407)248-5800 Engineer's Name& Phone# Sabo Structural Engineering(904)712-5750 Workers Compensation Policy N MWC30267702/Expries 9/1/2018 Exempt/Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE:In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINAN9N CONSULT WITH YOUR LENDER OR AN ATTO•14,Y BEFORE RECORDING YOU•// TICE OF COMMENCEMENT. Sign. ure. Owner or Agent) (gir re of Contractor) (In ding contractor) Signed and . orn to(or affirmed)before me this 8 day of Signed an. sworn to(or affirmed)before me this day of November 2018 by 5i:thitik.I?. modixt_ November 2018 by S`k.a Je ti.Mil zt.,,-.,- 90 II L L 11 ei ature of Notary) `Jr,r nature of Notary) personally Known OR 'ersonally Known OR J�N PN Notary Public State of Florida �1 v Notary Public Slate of Florida [ ]Produced Identification 4' `A Melissa Sue Lieberman r)Produced Identification `� Melissa Sue Lieberman Type of Identification: - - a My Commission GG 126006 pe of Identification: ..-'4.. ' M Commission GG 128068 v14,' 4t' Expires 00/18/2021 'f4r p Expires 6' : 6 PERMITTED BUILDING DATA DO NOT WRITE BELOW — OFFICE USE ONLY Applicable Codes: 6th Edition (2017) Florida Building Code DEVELOPMENT SIZE: Habitable Space (ft') 3 76/ Non-Habitable Space (ft") 2Z 7( LAND INFORMATION: Zoning District /7/C G Flood Zone X Minimum FFE/,do / proposed /ca./D ' BUILDING INFORMATION: Construction Type V f3 Occupancy Group Number of Stories O., Max Occupancy Load Fire Sprinklers Required CONDITIONS/ COMMENTS: Rev. 2.7.2018 FORM R405-2017 cia 74 0 r/ôrilq FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Julington 3761 Left SW Builder Name: Toll Brothers Inc. Street: 1607 Atlantic Beach Dr. Permit Office: Duval City,State,Zip: Atlantic Beach,FL 32233 Permit Number: Owner: Steve Merten Jurisdiction: 261300 Design Location: FL,Jacksonville/Intnl. County: Duval(Florida Climate Zone 2) 1.New construction or existing New(From Plans) 9. Wall types (4418 ft2) Insulation(R) Area(ft') 2.Single family or multiple family Single-Family a. Frm wall,wd ext,3/8"wood shth 19.0 3943.00 b. Frm wall,3/8"wood shth,r-13 c 13.0 475.00 3.Number of units,if multiple family 1 c. N/A 4.Number of bedrooms 5 d. N/A 10. Ceiling types (2943 ft') Insulation(R) Area(ft') 5.Is this a worst case? Noti a. Attic ceiling,mtl roof mat,r-1 19.0 456.50 6. Conditioned floor area above grade(ft') 3761.00 b. Attic ceiling,mtl roof mat,r-3 38.0 2486.00 Conditioned floor area below grade(ft') 0 c. N/A 7. Windows (638 ft') Description Area(ft2) 11.Ducts R Area(ft') a.Sup:House,Ret:House,AH:House 6.0 612.49 a.U-Factor: Dbl,0.340/ 637.70 b Sup:Second Floor,Ret Second Floor,AH:Second Floor 6.0 206.92 SHGC: 0.27 ,/ b.U-Factor: 12.Cooling systems kBtu/hr Efficiency SHGC: a.Split air source heat pump 46.0 SEER:14.0 c.U-Factor: b.Split air source heat pump 22.2 SEER:14.5 SHGC: ' 13.Heating systems kBtu/hr Efficiency d.U-Factor: a.Split air source heat pump 45.5 HSPF:8.2 SHGC: b.Split air source heat pump 22.2 HSPF:8.2 Area Weighted Average Overhang Depth: 6.025 ft 14.Hot water systems Area Weighted Average SHGC: 0.270 a.Gas instantaneous(0 gal) Cap:0 gal EF:0.82 8. Floor types(2942.50 ft') Insulation(R) Area(ft') b.Conservation features a. Bg floor,light dry soil,on gra 0.0 2683.75 (None) b. Fir floor,frm flr,6"thkns,ca 43.0 258.75 c. N/A 15.Credits None Glass/Floor area: 0.161 Total Proposed Modified Loads: 109.71 A PSS Total Baseline Loads: 116.20 /'-i I hereby certify that the plans and specifications covered by Review of the plans and specifications ,, ° VIUS7� this calculation are in compliance with the Florida Energy ' covered by this calculation indicates C'f�,, ,F ti r�. Code. compliance with the Florida Energy }' 1L- °,4, Code. Before construction is completed, co .. �ti* PREPARED BY: 5� 4,4./.4,. ? this building will be inspected for ,, com compliance with Section 553.908 10/17/2018 p t R _ DATE: Florida Statutes. 0 ,,t, F 1 • 4, e I hereby certify that this building,as designed, is in fj; „ti _�..' pEnergy n ��'NI CI E1� .- com compliance with the Flori 8 Code. OWNER/AGENT: 4 1 R,? ' r f J o .>r-_% BUILDING OFFICIAL: fil DATE: k� i Y !1' : DATE: �1/-/G-t r -Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50(R402.4.1.2). • 2018-Oct-17 14:30:36 -1161-wrightsoft't Comfort Builder by Wrightsoft 18.0.31 RSU03444 Right-Energy@ Florida 2017 Section 405.4.1 Compliant Software Page 2 � a L... ...Desktop\Julington 3761 Left SW-Lot 2 ABCC.rup Calc=MJ8 Front Door faces:SW f -\,'if City of Atlantic Beach I I � -` ��, APPLICATION NUMBER as !' � Building Department (To be assigned by the Building Department.) ti J. � 800 Seminole Road ���� � �� j � ^ /`��� :5 �r Atlantic Beach, Florida 32233-5445 t 0 Phone(904)247-5826 • Fax(904)247- "!.ri;;t9 E-mail: building-dept@coab.us NOVDate routed: (_4_51 4ww City web-site: http://w .coab.us 3 2018 APPLICATION REVIEW A COKING FORM Property Address: I LP 0-1 •P `Gu�{1 C,ii DE' Vl Department review required Yes No B IIsi Applicant: ( CS tk Y03 •canning &Zonin• 3 Tree Administrator Project: IQ e liu Cj F1--( PubEi ork) Public Utilitie-3 Public Safety Fire Services :Review fee $ 25 Dept Signature ati j Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection • Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLI ION STATUS Reviewing Department First Review: I Approved. I (Denied. I IN applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: ate: //-4.5=/ d" TREE ADMIN. Second Review: Approved as revise I Not applicable pp I (Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: Approved as revised. TIDenied. IiNot applicable Comments: Reviewed by: Date: Revised 05/19/2017 c.:11ir,,,';'.( ''T'':•. City of Atlantic Beach PUBLIC UTILITIES DEPARTMENT ' ,f!) 902 Assisi Lane � Jacksonville, FL 32233 - +_. r—,! ,v (904) 247-5834 NEW WATER / SEWER TAP REQUEST Date // /5 / g Service Address /607 R/ /41%JT/a Er b--- Number /Number of Units / Commercial Residential 1 Multi-Family New Water Tap(s) & Meter(s) Meter Size(s) 3/9 r r New Irrigation Meter '° Upgrade Existing Meter from to (size) 3 r New Reclaim Water Meter Size �� New Connection to City Sewer Applicant Name Billing Address City State Zip Phone Email Applicant Signature ���� CITY STAFF USE ONLY Application# 7Z& /8- 0 37 2_ Water System Development Charge $ /, /1/01( (fO Sewer System Development Charge $Y, r) SO, (17) Water Meter Only $ /8 S 0-0 Reclaim Meter Only $ /8S .LO Water Meter Tap $ Sewer Tap $ Cross Connection $ 50, O(3 Other $ TOTAL / $ 4 4/0 , 07) (Notes) APPROVED Date !//,r--/ (i blic Utilities Director or Authorized Signature ALL TAP REQUESTS MUST BE APPROVED BY THE PUBLIC UTILITIES DEPARTMENT BEFORE FEES CAN BE ASSESSED Cityof Atlantic Beach I 01.-up,), APPLICATION NUMBER isi �S y'��i Building Department ��w>� (To be assigned by the Building Department.) ✓ - - -- 800 Seminole Road IR g 0372--- , ` 2 .,-•, �r Atlantic Beach, Florida 32233-544 �f � S I J — O3 72., Phone (904)247-5826 • Fax(904) -589V � 3 2018 ;•0Ti r E-mail: building-dept@coab.us Bv. Date routed: 1 / INIIINI City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 162 d 1 IN-t,GLyk-1 C. 13E' G, Department review required Yes No B . •'•• Applicant: ( (2,t\ �Yo3 alarming &Zonin,• Tree Administrator Project: I v e 1A1 S F ' l ti ork) Public Utilities Public Safety Fire Services Review fee $ Dept Signature j Review or Receipt Other Agency Review or Permit Required of Permit Verified By Date Florida Dept. of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: • APPL CATION STATUS Reviewing Department First Review: Approved. I (Denied. Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by:40X2,74t4:RDate: /fr/1%�1, TREE ADMIN. Second Review: I !Not applicable !Approved as revised. Denied. PUBLIC WORKS Comments: • PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: I !Approved as revised. I (Denied. I .INot applicable Comments: Reviewed by: Date: Revised 05/19/2017 ,rt-!;AL. y, REVOCABLE ENCROACHMENT AGREEMENT '-i ` , . City of Atlantic Beach **ALL INFORMATION 1 "� ) HIGHLIGHTED IN GRAY ,-'Y 800 Seminole Road,Atlantic Beach,FL 32233 IS REQUIRED. ?7,is a. REVOCABLE ENCROACHMENT AGREEMENT by the City of Atlantic Beach, Florida, a municipal corporation organized and existing under the laws of the State of Florida, hereinafter referred to as"CITY"and of Atlantic Beach, Florida, hereinafter referred to as "USER'roLL FL VI,LP WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property for the purpose as described in the City of Atlantic Beach. This work is generally described as . Roam in the Riyld-of-Wey I'm ttre Mivewdy. Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty(30)days'notice by CITY to USER,said notice to USER shall be given by certified mail,return receipt requested,to the following address 1607 Attantin Reach Dr Parent 1167-13?0R-7S-29F • • In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above described easement or property of the CITY, the USER shall replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining, repairing, operating, replacing or adding to of the utilities and facilities of the CITY or franchise utility provider. • The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes, Land Development Code and all other land use and code requirements of the CITY, including City Code Section 19-7(h) which states"Driveways that cross sidewalks: City sidewalks may not be replaced with other materials, but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." • The USER, prior to making any changes from the approved plans and/or method, must obtain written approval from the City of Atlantic Beach Public Works Department, for said change within 30 days after the day of completion. • This permit shall inure to the benefit of, and be binding upon, the USER and their respective successors and assigns. • USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications, to include utilities locate requirements and use limitations/requirements of easements, public right-of-ways and other public land. USER further agrees that the CITY and its officers and employees shall be saved harmless by tl • BSER from any of the work herein under the terms of this permit and that all of said liabilities are her . sumed by the USER. ADate 11rhe Property Owner Age :ned in presence of Notary Public) STATE OF FLORIDA,COUNTY OF DUVAL The foregoing instrument was acknowledged this , day of ►k1'w11. ?Pvl., , 20 I' , by Ste,ve, Maim. ,who personally appeared before me and (printed name of Signer) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. • ,,,..01144._ Notr " aPubiicSateofFIonda Department Approval' '`* Melissa Sue Lieberman Sign thre of Notary Public, State of Fr",,,,,,e,m,,,,s‘ d �; , , MyCornmissionGC;126088 [ Personally Known '?a ha` Expires 09nII/2021 , //� ' /� [ ]Produced Identification(Type) Scott illiams, Public Works Director H:\Applications&Forms\Word Documents\20180831 Revocable Encroachment Agreement.docx Revision Date:8/31/18 Irititib 11 A cRIGHT-OP-WAY/ EASEMENT PERMIT Permit#Issued by the City of Atlantic Beach PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES Job Address 1607 Atlantic Beach Drive Phone 904-595-5243 Permittee Steven Marten Email aregnierrt?atoilbrothers.com Requesting Permission to Construct Pavers in the Right of Way for the driveway Location(Reference to Cross-Street) Atlantic Beach Dr&Timber Bridge Ln -06884 ATLANTIC BEACH COUNTRY CLUB UNIT 02 • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement,maintenance,safe and efficient operation, alteration or relocation of all,or any portion of said street or easement as determined by the Director of Public Works,any or all said poles,wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed tinder the supervision of Siacia Moore (Project Superintendent) located at 237 9th Avenue North,Suite 4,Jacksonville Beach,FL 32250 , • All materials and equipment shall be subject to inspection by the Director of Public Works. • All city property shall be restored to its original condition as far as practical,in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • The perinittee shall commence actual construction in good faith within days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,title and interest in the land to be entered upon and used by the holder, and the holder will,at all times, assume all risk of and indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and • 'vileges. • The Director of Publ., Torks shall be notified twenty-four(24)hours prior to starting work and again immediately upooiusletion. 1AO.Pc. Date kithe it Permittee:Steven R. f erte ,D. ision President,TOLLFL VI,LP(signed in presence of Notary Public) STATE OF FLORIDA,COUNTY OF SAINT JOHNS The foregoing instrument was acknowledged this $, day of NtrAt j,{kj> 2._ ,201 , by SteVE.rt- i+6(L ,who personally appeared before me and (printed name of Pennittee) acknowled_ed that a/she signed the instrument voluntarily for the purpose expressed in it. illP Personally Known u---'f- Signatur my Public,State of Florida Produced Identification(Type) ‘4,100,;:,,,,^ Notary Public State of Florida Melissa Sue Lieberman 1� ~�, .,� My Commission GG 120080 ,60,rtio expires 0011812021 I � 1-41`1rit. City of Atlantic Beach APPLICATION NUMBER _4S fl Building Department (To be assigned bythe BuildingDepartment.) r ,. „� 9 P ) r. • - 800 Seminole Road Qg /` -r• Atlantic Beach, Florida 32233-5445 !\ J - V��� Phone(904)247-5826 • Fax(904)247-5845 LJ 31�r E-mail: building-dept@coab.us Date routed: t r I City web-site: http://www.coab.us111111 APPLICATION REVIEW AND TRACKING FORM Property Address: I La d 1 ��lc��� L "BE'.0 k Department review required Yes No pQ Applicant: ( O 11 ]j yR 3 tinning &Zonin _7 Tree Administrator Project: 1" e il.l F .PublEs-V�ork Public Utilitf`e� Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection . Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. I 'Denied. I Not applicable (Circle one.) Comments: BUILDING ><PLANNING &ZONING Reviewed by:� Date: 3" TREE ADMIN. Second Review: Approved as revised. nDenied. INot applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: I 'Approved as revised. I 'Denied. f Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 PRODUCT APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC/B^EACH,FLORIDA Project Name: Toll Brothers,Inc. Permit# RES l ? —a 7 GI Project Address: 1607 Atlantic Beach Drive Lot 2 As required by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72,please provide the information and product approval number(s) for the building components listed below as applicable to the building construction project for the permit number listed above. You should contact your product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at:www.floridabuilding.org. Category/Subcategory Manufacturer Product Description Limitation of Use State# Local # A. EXTERIOR DOORS 1. Swinging Masonite Wood Edge,Steel N/A Double-FL8228.6 Single-FL6506.4 Simpson Door Company Wood Door FL 14487.1 Therma-Tru Fiberglass/Wood Door N/A FL 5262.3 2. Sliding PGT 2500 Aluminum Slide Glass +25/-25 FL 251 3. Sectional +43.2/-49.6 8 ft FL 9174.12 Wayne Dalton Section Ext.Door +39.2/-43.7 16ft FL 9174.15 4.Roll up 5.Automatic 6. Other B. WINDOWS 1. Single Hung PGT 5400 Vinyl Single Window +50/-50 FL 1435 2.Horizontal slider PGT 5400 Vinyl Hor. Window +50/-50 FL 1844 3.Casement 4.Double hung 5.Fixed PGT 5400 Vinyl Fixed Window +50/-50 FL 5012 6.Awning 7.Pass-through 8.Projected 9.Mullion PGT Alum/Vinyl Mullions N/A FL 261 10.Wind Breaker 11. Store Front/Mitred Glass Kawneer Glass Windows Mitred Glass Windows +30/-30 FL 10008.1 12. Glass Block US Block/Hy-Lite Glass Block Window 70 PSF FL 185.12 Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# C.PANEL WALL 1.Siding James Hardie Building Products,Inc. Lap Siding and Shingle Panels N/A FL 13192.2; 13192.4 James Hardie Building Products,Inc. Lap Siding and Shingles N/A FL 10477.1 FL 12098.3; 12098.1; Nichiha Corp. Lap Siding and Shingles N/A 12875.1 2.Soffits/Ceilings James Hardie Building Products, Inc. Soffit Panels N/A FL 13265.1 Nichiha Corp. Soffit Panels N/A FL 12098.4 3.EIFS 4.Storefronts Kawneer Glass Windows Mitred Glass +30/-30 FL 10008.1 5.Curtain walls 6.Wall louvers 7.Glass block 8.Membrane 9.Greenhouse 10.Synthetic Stucco 11.Other D.ROOFING PRODUCTS 1.Asphalt shingles GAF Corp. Timberline 30 year Arch Shingles N/A FL 10124.1 2.Underlayments Woodland Industries,Inc. Felt N/A FL 1814.12 Boral Roofing Roof Underlayment N/A FL 14317.1 3.Roofing fastners 4.Nonstructural metal roof Millennium Metals,Inc. Metal Roofing-M seam N/A FL 5211.3 R6 5.Built-up roofing 6.Modified bitumen 7.Single ply roofing 8.Roofing tiles 9.Roofing insulation 10.Waterproofing 11.Wood shingles/stakes Watkins Sawmill LTD. Wood Shingles and Shake NiA FL 13714.1 12.Roofing slate 13.Liquid applied roofing 14.Cement-adhesive coats 15.Roof tile adhesive 16. Spray applied polyurethane roof 17.Other Ph-Deck \Walking deck membrane N/A FL 12407.1 Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# E.SHUTTERS 1.Accordion 2.Bahama 3.Storm panels Town and Country Industries Storm shutters N/A FL 11963 4.Colonial 5.Roll-up 6.Equipment 7.Other F. STRUCTURAL COMPONENTS 1.Wood connector/anchor Simpson Strong Tie Per engineering 2.Truss plates Alpine Engineered Truss plate conn. Per engineering 3.Engineered lumber Georgia Pacific Eng.Lumber FL 2023.1 4.Railing 5.Coolers-freezers 6.Concrete admixtures 7.Material 8.Insulation forms 9.Plastics 10.Deck-roof 11.Wall 12.Sheds 13.Other G.SKYLIGHTS 1.Skylight Sun Tek FGC Skylite FL 2442 2.Other H.NEW EXTERIOR ENVELOPE PRODUCTS 1 7/16"Zip Wall-Structural 1 OSB(roof and wall);manufacturered by Huber Engineered Woods 2 In addition to completing the above list of manufacturers,product description and State approval number for the products used on this project,the Contractor shall maintain on the job site and available to the Inspector,a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. Audrey Regnier '�// ..e7..-4 (Contractor Name) (Print Name) (Signature Company Name: Toll Brothers,Inc. Mailing Address: 160 Cape May Avenue City: Ponte Vedra State: FL Zip Code: 32081 Telephone Number: 904 217-0739 Fax Number: Cell Phone Number: 904-405-8969 Email Address: aregnier@tollbrothers.com \CBUCK ngin rin Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Evaluation Report "M-Seam" Metal Roof Assembly Manufacturer: Millennium Metals, Inc. 10200 Eastport Road Jacksonville, FL 32218 (877) 358-7663 for Florida Product Approval it FL 5211.3 R6 Florida Building Code 5th Edition (2014) Per Rule 61G20-3 Method: 1 - D Category: Roofing Sub - Category: Metal Roofing Product: "M-Seam" Material: Steel Panel Thickness: 26 gauge, (Minimum) Panel Width: 16" Support: Wood Deck Digitally signed by James L.Buckner,P.E. Electronically signed and sealed documents shall comply with the provisions of FAC Rule Prepared by: 61615-23.�\\\\\lI Illlll�r, James L. Buckner, P.E., SECB �� �s c Buc,ti%,' Florida Professional Engineer # 31242 tCENSc''••t*•. Florida Evaluation ANE ID: 1916 = • * "°3'242 _ D * : �_ Project Manager: Youry Demosthenes Report No. 15-104-M-S6W-ER ; ,�'•. STATE OF (Revises 12-117-M-S6W-ER) ��s ; •••ORIDp•.•' Date: 7/ 1/ 15 /„S;ONAL�?\\�\ Contents: Evaluation Report Pages 1—7 CBUCK, Inc. 2015.07.01 11:03:27-04'00' 1399 N. Killian Drive,Suite 4,West Palm Beach, Florida 33403 Phone:(561)491-9927• Email:cbuck@cbuckinc.net•Website:www.cbuckinc.net FL#: FL 5211.3-R6 Date: 7/ 1/ 15 r " "LJ � nIRe OrtNO.: 15104M56W- ER Page 2 of 7 Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Manufacturer: Millennium Metals, Inc. Product Name: "M-Seam" Product Category: Roofing Product Sub-Category Metal Roofing Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) Product/System "M-Seam" Description: 26 gauge Minimum, Steel roof panel mechanically attached to Plywood Deck with screws. Product Assembly as Refer to Page 4 of this report for product assembly components/materials & Evaluated: standards: 1. Roof Panel 2. Fasteners 3. Underlayment 4. Insulation (Optional) Support: Type: Wood Deck (Design of support and its attachment to support framing is outside the scope of this evaluation.) Description: • 15/32 (min.) or 19/32"or greater plywood, • or Wood plank(min. specific gravity of 0.42) Slope: Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2, applicable code sections and in accordance with manufacturer's recommendations. Performance: Wind Uplift Resistance: • Design Uplift Pressure: Refer to Table "A" (Refer to"Table A" attachment details herein) FL#: FL 5211.3-R6 Date: 7/ 1/15 'LICK k. "� �''` ri -- Report No.: 15-104-M-S6W-ER IV Page 3 of 7 Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Performance Standards: The product described herein has demonstrated compliance with: • UL580-06—Test for Uplift Resistance of Roof Assemblies • UL 1897-04—Uplift test for roof covering systems Standards Equivalency: • The UL 580-94 standard version used to test the evaluated product assembly is equivalent to UL580-06 standard version adopted by the Florida Building Code 5th Edition (2014). • The UL 1897-98 standard version used to test the evaluated product assembly is equivalent to UL1897-04 standard version adopted by the Florida Building Code 5th Edition (2014). Code Compliance: The product described herein has demonstrated compliance with Florida Building Code 5th Edition (2014), Section 1504.3.2. Evaluation Report This product evaluation is limited to compliance with the structural requirements of Scope: the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Limitations and • Scope of"Limitations and Conditions of Use"for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval" contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under"Optional Statewide Approval". • Option for application outside "Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade& Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization #: QUA 1824). \ FL#: FL 5211.3-R6 Date: 7/ 1/ 15 (1791JE7K Encilnehering Report No.: 15-104-M-S6W-ER Page 4 of 7 Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Components/Materials Roof Panel: "M-Seam" (by Manufacturer): Material: Steel Thickness: 26 gauge Minimum Panel Width: 16" (max.)Coverage Rib Height: 1" Yield Strength: 40 ksi min. Corrosion Resistance: In compliance with FBC Section 1507.4.3: • ASTM A792 coated, or • ASTM A653 G90 galvanized steel Fastener: Type: Pancake-Head Wood Screw Size : #10 x 1" Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4 Standard: Per ANSI/ASME B18.6.4 Components/Materials Underlayment: (by Others): Material and application shall be in compliance with FBC Section 1507.4.5.1 and 1507.4.5.2, applicable codes and in accordance with manufacturer's recommendations. Insulation (Optional): Type: Rigid Insulation Board Thickness: 3" (max.) Properties: Density: 2.25 pcf(lbs/ft3) min. Or Compressive Strength: 20 psi min. Insulation Notes: • Rigid Insulation shall meet minimum density OR compressive strength. • Insulation shall comply with FBC Section 1508. When insulation is incorporated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/16". FL#: FL 5211.3-R6 �yr p t �r�► Date: 7/ 1/ 15 CBUCK n in e! nQ Page Report No.: 5 of 7 M-104 -ER Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Installation: Installation Method: (Refer to drawings on Pages 6-7 of this report.) • Fastener spacing: Refer to Table"A" Below (along the length of the panel) • Rib Interlock: Snap Lock (Panel ribs shall be fully engaged to form an integral interlock. ) • Minimum fastener penetration thru bottom of support, 3/16". • For panel construction at the end of panels, refer to manufacturer's instructions and any site specific design. TABLE "A" ALLOWABLE LOADS METHOD 1: METHOD 2: * Design Pressure: -84.25 PSF -91.75 PSF Deck Thickness: 15/32" or 19/32" 15/32"or 19/32" Fastener Spacing: 8" 4" *Allowable design pressure for allowable stress design(ASD)with a margin of safety of 2 to 1. Install the "M-Seam" roof panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 5th Edition (2014). The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Referenced Data: 1. UL580-94& UL 1897-98 Uplift Test By Hurricane Test Laboratory, LLC(FBC Organization#TST ID: 1527) Report#: 0232-0508-05, Report Date: 6/29/05, Specimens#1-3 2. Quality Assurance By Keystone Certifications, Inc. (QUA ID: 1824) Millennium Metals Licensee#423 3. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) 4. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization#ANE 1916) FL#: FL 5211.3-R6 r t Date: 7/ 1/ 15 CBUCKE ! 1 r n Report No.: 104M-s6W ER Page 6 of 7 Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Installation Method Millennium Metals "M-Seam" Roof Panel Attached to Wood Deck Profile Drawings 1" 16"Coverage i L --. ."-- Optional Striations 314" Typical Panel Profile View -� 16"o.c. `_ L-- -- -------- --- _-- __-- -- ..;:„ Integral Snap Lock — #10 Pancake-Head Screw 3/16"min. penetration thru deck 4 Ilhi ---:..– i i $ Typical Assembly Profile View FL#: FL 5211.3-R6 Date: 7/ 1/ 15 ..,A::u,3..GG.xu l L- E r1 �, . eport o.: 15-104-M-56W-ER Page 7 of 7 Specialty Structural Engineering CBUCK,Inc.Certificate of Authorization#8064 Installation Method Millennium Metals "M-Seam" Roof Panel Attached to Wood Deck Fastener: #10 Pancake-Head Scre "M-Seam"Roof Paneli ____/1 // r // / i / / % r j r / /// i? l f !/ / f / / r / I \—Deck: ---__ _���_------------\ Insulation: -15/32"or 19/32"or greater Plywood,or (Optional)Wood plank (Optional)3"max or 25 psi min. Typical Assembly Profile View TABLE "A" ALLOWABLE LOADS METHOD 1: METHOD 2: * Design Pressure: -84.25 PSF -91.75 PSF Deck Thickness: 15/32"or 19/32" 15/32" or 19/32" Fastener Spacing: 8" 4" *Allowable design pressure for allowable stress design(ASD)with a margin of safety of 2 to 1. FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Julington 3761 Left SW Builder Name: Toll Brothers Inc. Street: 1607 Atlantic Beach Dr. Permit Office: Duval City,State,Zip: Atlantic Beach,FL 32233 Permit Number: Owner: Steve Merten Jurisdiction: 261300 Design Location: FL,Jacksonville/Intnl. County: Duval(Florida Climate Zone 2) 1.New construction or existing New(From Plans) 9. Wall types (4418 ft') Insulation(R) Area(ft2) 2.Single family or multiple family Single-Family a. Frm wall,wd ext,3/8"wood shth 19.0 3943.00 b. Frm wall,3/8"wood shth,r-13 c 13.0 475.00 3.Number of units,if multiple family 1 c. N/A 4.Number of bedrooms 5 d. N/A 10. Ceiling types (2943 ft') Insulation(R) Area(ft2) 5.Is this a worst case? No a. Attic ceiling,mtl roof mat,r-1 19.0 456.50 6.Conditioned floor area above grade(ft°) 3761.00 b. Attic ceiling,mtl roof mat,r-3 38.0 2486.00 Conditioned floor area below grade(ft') 0 c. N/A 7. Windows (638 ft2) Description Area(ft') 11.Ducts R Area(ft') a.Sup:House,Ret:House,AH:House 6.0 612.49 a.U-Factor: Dbl,0.340 637.70 b.Sup:Second Floor,Ret Second Floor,AH.Second Floor 6.0 206.92 SHGC: 0.27 b.U-Factor: 12.Cooling systems kBtu/hr Efficiency SHGC: a.Split air source heat pump 46.0 SEER:14.0 c.U-Factor: b.Split air source heat pump 22.2 SEER:14.5 SHGC: 13.Heating systems kBtu/hr Efficiency d.U-Factor: a.Split air source heat pump 45.5 HSPF:8.2 SHGC: b.Split air source heat pump 22.2 HSPF:8.2 Area Weighted Average Overhang Depth: 6.025 ft 14.Hot water systems Area Weighted Average SHGC: 0.270 a.Gas instantaneous(0 gal) Cap:0 gal EF:0.82 8. Floor types(2942.50 ft°) Insulation(R) Area(ft2) b.Conservation features a. Bg floor,light dry soil,on gra 0.0 2683.75 (None) b. Fir floor,frm flr,6"thkns,ca 43.0 258.75 c. N/A 15.Credits None Glass/Floor area: 0.161 Total Proposed Modified Loads: 109.71 PASS Total Baseline Loads: 116.20 I hereby certify that the plans and specifications covered by Review of the plans and specifications w' covered bythis calculation indicates /0 t°4H Sri?. this calculation are in compliance with the Florida Energy ,,,�,- .�,,�.�'� Code. compliance with the Florida Energy �P ik Code. Before construction is completed, L,- .r PREPARED BY: 50,,,.. ..9. this building will be inspected for /'• ,, 1,- , . t 10/17/2018 compliance with Section 553.908 DATE: Florida Statutes. as E ,� laic . t it I hereby certify that this building,as designed, is in ,+�1 " 4C compliance with the Flori Energy Code. or riE OWNER/AGENT: BUILDING OFFICIAL: /712" DATE: k`/2`1T DATE: //-/b-/ O -Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50(R402.4.1.2). 4 2018-Oct-17 14:30:36 nwrightsoft" Comfort Builder by Wrightsoft 18.0.31 RSU03444 Right-Energy® Florida 2017 Section 405.4.1 Compliant Software Page 2 , ...Desktop\Julington 3761 Left SW-Lot 2 ABCC.rup Calc=MJ8 Front Door faces:SW FORM R405-2017 Building Input Summary Report PROJECT Title: Julington 3761 Left SW Bedrooms: 5 Address type: Street address Building Type: FLAsBuilt Bathrooms: 3 Lot#: 2 ABCC Owner: Steve Merten Conditioned Area: 3761 Block/Subdivision: Atlantic Beach Country CI Jb #of Units: 1 Total Stories: 2 Platbook: Builder Name: Toll Brothers Inc. Worst Case: No Street: 1607 Atlantic Beach Permit Office: Duval Rotate Angle: 0 County: Duval Jurisdiction: 261300 Cross Ventilation: No City, State,Zip: Atlantic Beach, FL 32233 Family Type: Single-Family Whole House Fan: No New/Existing: New(From Plans) Terrain: Suburban Year Construct: 2018 Shielding: Suburban Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp •+` Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville/Intnl. FL_Jacksonville-Cr 2 29 98 70 75 1327 62 Medium BLOCKS # Name Area Volume 1 Second Floor 1289.00 ft2 11601.00 ft3 2 House 2683.75 ft2 26837.50 ft' SPACES # Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 master bath 229.00 ft2 2290.00 ft' No 0 0 1 Yes Yes Yes 2 master bed 288.00 ft2 2880.00 ft' No 2 1 1 Yes Yes Yes 3 laundry 92.00 ft2 920.00 ft3 No 0 0 1 Yes Yes Yes 4 ahu 36.00 ft2 360.00 ft' No 0 0 1 Yes Yes Yes 5 entry 48.00 ft2 480.00 ft' No 0 0 1 Yes Yes Yes 6 pwdr 35.75 ft2 357.50 ft3 No 0 0 1 Yes Yes Yes 7stairs/foyer 368.75 ft2 3687.50 ft' No 0 0 1 Yes Yes Yes 8 2 188.25 ft2 1882.50 ft' No 1 1 1 Yes Yes Yes 9 wic 2 46.75 ft2 467.50 ft3 No 0 0 1 Yes Yes Yes 10 bath 2 51.00 ft2 510.00 ft' No 0 0 1 Yes Yes Yes 11 study 193.75 ft2 1937.50 ft' No 1 0 1 Yes Yes Yes 12 pantry 65.00 ft2 650.00 ft' No 0 0 1 Yes Yes Yes 13 kitchen 304.50 ft2 3045.00 ft' Yes 0 0 1 Yes Yes Yes 14 dining 159.50 ft2 1595.00 ft' No 0 0 1 Yes Yes Yes 15 great room 436.50 ft2 4365.00 ft' No 0 0 1 Yes Yes Yes 16 we 21.00 ft2 210.00 ft3 No 0 0 1 Yes Yes Yes 17 gallery 146.00 ft2 1314.00 ft' No 0 0 1 Yes Yes Yes 18 open to below 261.00 ft2 2349.00 ft3 No 0 0 1 Yes Yes Yes 19 bed 4 201.50 ft2 1813.50 ft3 No 1 1 1 Yes Yes Yes 20 bed 3 201.50 ft2 1813.50 ft' No 1 1 1 Yes Yes Yes 21 wic 3 33.00 ft2 297.00 ft' No 0 0 1 Yes Yes Yes 22 wic 4 30.25 ft2 272.25 ft' No 0 0 1 Yes Yes Yes 23 sinks 30.25 ft2 272.25 ft' No 0 0 1 Yes Yes Yes 24 master wic 120.00 ft2 1200.00 ft' No 0 0 1 Yes Yes Yes 25 bath 3 33.00 ft2 297.00 ft' No 0 0 1 Yes Yes Yes 26 bonus rm. 320.50 ft2 2884.50 ft' No 1 1 1 Yes Yes Yes 27 ah 16.00 ft2 144.00 ft' No 0 0 1 Yes Yes Yes 28 b.wic 16.00 ft2 144.00 ft' No 0 0 1 Yes Yes Yes wrightsoft Comfort Builder by Wrightson18.0.31 RSU03444 Right-Energy®Florida 2017 Section 405.4.1 Compliant Software 14:30:36 Page 3 ,.,:,,_ ...Desktop\Julington 3761 Left SW-Lot 2 ABCC.rup Calc=MJ8 Front Door faces:SW FORM R405-2017 FLOORS (Total Exposed Area=2943 sq.ft.) 1 # Floor Type Space Perimeter R-Value Area U-Factor Tile Wood Carpet 1 Bg floor,light dry soil,on grade depth master bath 17 ft__0 229.00 ft' 0.989 0 1.0 0 2 Bg floor,light dry soil,on grade depth master bed 50 ft 0 288.00 ft2 0.989 0 1.0 0 3 Bg floor,light dry soil,on grade depth laundry 0 ft 0 92.00 ft2 0.989 0 1.0 0 4 Bg floor,light dry soil,on grade depth ahu 0 ft 0 36.00 ft2 0.989 0 1.0 0 5 Bg floor,light dry soil,on grade depth entry 0 ft 0 48.00 ft' 0.989 0 1.0 0 6 Bg floor,light dry soil,on grade depth pwdr 6 ft 0 35.75 ft2 0.989 0 1.0 0 7 Bg floor,light dry soil,on grade depth stairs/foyer 11 ft 0 368.75 ft2 0.989 0 1.0 0 8 Bg floor,light dry soil,on grade depth bed 2 40 ft 0 188.25 ft2 0.989 0 1.0 0 9 Bg floor,light dry soil,on grade depth wic 2 9 ft 0 46.75 ft2 0.989 0 1.0 0 10 Bg floor,light dry soil,on grade depth bath 2 0 ft 0 51.00 ft2 0.989 0 1.0 0 11 Bg floor,light dry soil,on grade depth study 13 ft 0 193.75 ft2 0.989 0 1.0 0 12 Bg floor,light dry soil,on grade depth pantry 5 ft 0 65.00 ft' 0.989 0 1.0 0 13 Bg floor,light dry soil,on grade depth kitchen 21 ft 0 304.50 ft2 0.989 0 1.0 0 14 Bg floor,light dry soil,on grade depth dining 37 ft 0 159.50 ft' 0.989 0 1.0 0 15 Bg floor,light dry soil,on grade depth great room 21 ft 0 436.50 ft' 0.989 0 1.0 0 16 Bg floor,light dry soil,on grade depth wc 4 ft 0 21.00 ft' 0.989 0 1.0 0 17 Bg floor,light dry soil,on grade depth master wic 0 ft 0 120.00 ft2 0.989 0 1.0 0 18 Fir floor,frm flr,6"thkns,carpet fir fnsh,r- bonus rm. 47 ft 43 257.50 ft2 0.049 0 0 1.0 19 Fir floor,frm flr,6"thkns,carpet fir fnsh,r- b.wic 0 ft 43 1.25 ft2 0.049 0 0 1.0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip RoofMetal 1441 ft' Medium 0.75 No 0.90 No 0 27 /2 Hip RoofMetal 1849 ft' Dark 0.75 No 0.90 No 0 27 ,/3 Hip RoofMetal 477 ft2 Dark 0.75 No 0.90 No 0 27 ATTIC 1 # Type Ventilation Vent Ratio(1 ink_ Area RBS IRCC 1 Full attic Vented 300 1289.00ft' N N 2 Full attic Vented 300 1653.50 ft2 N N ,..3 Full attic Vented 300 426.75 ft2 N N CEILING (Total Exposed Area=2943 sq.ft.) ' # Ceiling Type Space R Value_ U-Factor ._,..._. Area Framing Fraction Truss Type / 1 Attic ceiling,mt roof mat,r-19 ce master bath 19 0.054 8.25 ft2 0.11 Wood 2 Attic ceiling,mt roof mat,r-38 ce master bath 38 0.027 220.75 ft2 0.11 Wood 3 Attic ceiling,mt roof mat,r-19 ce master bed 19 0.054 24.50 ft' 0.11 Wood 4 Attic ceiling,mt roof mat,r-38 ce master bed 38 0.027 263.50 ft2 0.11 Wood 5 Attic ceiling,mt roof mat,r-38 ce laundry 38 0.027 88.00 ft2 0.11 Wood 6 Attic ceiling,mt roof mat,r-38 ce ahu 38 0.027 2.25 ft' 0.11 Wood 7 Attic ceiling,mt roof mat,r-38 ce entry 38 0.027 3.25 ft2 0.11 Wood 8 Attic ceiling,mt roof mat,r-19 ce pwdr 19 0.054 0.75 ft2 0.11 Wood 9 Attic ceiling,mt roof mat,r-38 ce pwdr 38 0.027 0.75 ft2 0.11 Wood 10 Attic ceiling,mt roof mat,r-19 ce kitchen 19 0.054 10.75 ft' 0.11 Wood 11 Attic ceiling,mt roof mat,r-38 ce kitchen 38 0.027 293.75 ft' 0.11 Wood 12 Attic ceiling,mt roof mat,r-19 ce dining 19 0.054 17.75 ft2 0.11 Wood 13 Attic ceiling,mt roof mat,r-38 ce dining 38 0.027 141.75 ft2 0.11 Wood 14 Attic ceiling,mt roof mat,r-19 ce great room 19 • 0.054 10.75 ft' 0.11 Wood 15 Attic ceiling,mt roof mat,r-38 ce great room 38 0.027 425.75 ft2 0.11 Wood 16 Attic ceiling,mt roof mat,r-19 ce wc 19 0.054 1.75 ft2 0.11 Wood 17 Attic ceiling,mt roof mat,r-38 ce wc 38 0.027 19.25 ft2 0.11 Wood 18 Attic ceiling,mt roof mat,r-19 ce gallery 19 0.054 8.00 ft2 0.11 Wood 19 Attic ceiling,mt roof mat,r-38 ce gallery 38 0.027 138.00 ft' 0.11 Wood 20 Attic ceiling,mt roof mat,r-19 ce open to below 19 0.054 11.50 ft' 0.11 Wood 21 Attic ceiling,mt roof mat,r-38 ce open to below 38 0.027 249.50 ft' 0.11 Wood 22 Attic ceiling,mt roof mat,r-19 ce bed 4 19 0.054 14.00 ft' 0.11 Wood 23 Attic ceiling,mt roof mat,r-38 ce bed 4 38 0.027 187.50 ft2 0.11 Wood 24 Attic ceiling,mt roof mat,r-19 ce bed 3 19 0.054 20.25 ft2 0.11 Wood 25 Attic ceiling,mt roof mat,r-38 ce bed 3 38 0.027 181.25 ft' 0.11 Wood 26 Attic ceiling,mt roof mat,r-19 ce wic 3 19 0.054 3.00 ft' 0.11 Wood 27 Attic ceiling,mt roof mat,r-38 ce wic 3 38 0.027 30.00 ft2 0.11 Wood 28 Attic ceiling,mt roof mat,r-19 ce wic 4 19 0.054 2.75 ft2 0.11 Wood 29 Attic ceiling,mt roof mat,r-38 ce wic 4 38 0.027 27.50 ft2 0.11 Wood 30 Attic ceiling,mt roof mat,r-38 ce sinks 38 0.027 30.25 ft2 0.11 Wood 31 Attic ceiling,mt roof mat,r-38 ce master wic 38 0.027 120.00 ft2 0.11 Wood 32 Attic ceiling,mt roof mat,r-38 ce bath 3 38 0.027 33.00 ft2 0.11 Wood 33 Attic ceiling,mt roof mat,r-19 ce bonus rm. 19 0.054 320.50 ft' 0.11 Wood 34 Attic ceiling,mt roof mat,r-19 ce ah 19 0.054 2.00 ft2 0.11 Wood 35 Attic ceiling,mt roof mat,r-38 ce ah 38 0.027 14.00 ft' 0.11 Wood 36 Attic ceiling,mt roof mat,r-38 ce b.wic 38 0.027 16.00 ft' 0.11 Wood Comfort Builder byWri htsoft 18.0.31 RSU03444 Right-Energy® Florida 2017 Section 405.4.1 Compliant Softw2018-Oct-17 14:3 e6 W I'1f�htSOI"k 9 9 9Y P Page 4 1,,. .,. ..., ...Desktop\Julington 3761 Left SW-Lot 2 ABCC.rup Calc=MJ8 Front Door faces:SW % , NNN * Nf It 4N.WWWWWWWWWWNN N N N NN N N N cpWVD7(7''1'.WNL 4k N•--.0(0M-4McJIAWN�OWWVOCTAWN- �k OCDW V01 CnAWN�OCOOOJOCT AWN-�O(DOOJWCTAWN�O ZZWZ, OMZWC%WZZZZWZZZWZC WWWZMW, W W ZCnz, Z 0 •A m *m mmg*mmm*m***m*mmmmmmg*m *' *" ' *mm * w O 2. zcnzcncncnzwzzzcnzwmcn ncnzzzz 0 to � mmrn�mmm�m��gm��0 mmmmmmmmmmmmmmmmmmmmmmmmmmmmvmvmmvmmmmmm v +.� xxxxmxxxxxxxxxxxxxxxxxxxxxxxmxmxmmmxxxmx 0- O +"# _* �z 1 D mmmm?ccommmmmmmmmmmmmmmmcmmommcm �?cm?a mmc�?m o °' J 3T WWWWWWNNNNNNN����OCTW�� CD M1p COMVr cmco TAWN-,OJAW-, 00 j 0000000000000000000000000000000000000000 m co 0 = -,7 7"7-,7=Z-,-,-,7-", 0 0 0) D ««««< c T m3 N »>»»m3'=•c3"5733"33333 N icg DC <<' <<•<•<• <E'<s..<,< `<`<•GK`G` '< 3 TiTImmmrnmm-rimmmmmmmmmrnmrnmTmmm-riTmrnmrnmrnm -rimm l v6m CD 3333333333333333333333333333333333333333 cE. rrrr g 0000000000000000000000 ********F*****ff*f*F*f********ff*F*FF*DCD R 1 * *** *FF*FF****FF*** mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmm mC ! 000. llflm0_ mfmmTTTf0_ mTIfRv oo oo i0 E w*******fig*gig**g*fig*g *w*Lo c,)*g g W* f, 1 G' i 0000000000000000000000 m -,-, ' 0 naaa�nnaanano.annannaaao-nnnao_o_ m�aaa66n �_, 0000000000000000000000 N o CCDCCD -mmmmmmmmmmm mmmmmmm CD CD C CD m -m -m - - -m mm -m CD m o 'CD C 0 C C C C C C C C C C C C C C C C C C 0 0 0 �, !m 0-0-Qo•o'0•0-0-0-0-0-0-0-0-0-0-a0-0-0-0-0- nn I H xxxxfxxxxxxxxxxxxxxxxxxxxxxx*xfxf*Fxxxfx mo _: mmmmmmmmmmmmmmmmmmmmmm cncn > � �= M;(O i m 00 C< H D ZZ -oo3 mm o wm mco _33333 <O mm 0007==,,,* O'O'660-77,00 (110.0_0. N*60-0—= �0m mNNNNN C0_ rwwwww � ;a) -<C-<GG ���� -«����� 1 Z mccc^p5•3ao.0_0_01oo� , ..7750 c�'m"Sf..4 =nommm� m ° m m m m m m m m m m m m m m m m m m m m m m T 7 N N N 6m0----=-m G.0., N v) MN N N N N N N N N N N N N Cr,N N N N co N N X "A W W W W A A Cr Cr, 00 O(Q(f]�.. '<N N NN<,� `<C�Q Q QC7 CT m DC C> 333 • O0 3 mc-, 0.0.01=- oW ** .3 '' ;0 O OO O O O O 00 0 0 0 00 0 0 0 00 O o O C DC on WWWWWWWWWWWWWWWWWWWWWW 1 N • cD(oOCDW00OOOCDCOCOCOOCDC0c0OCO(OCDCDc0OMC0cDWOWOWWWo0CDWcO N<. C7 'm 0 AAA A A A A AA A A A AA A A A AA A A A O •-'m C�< C y a 0 OO O o 0 0 00 0 0 0 00 0 0 O OO O O O a m D 0 Z Q A D'� 0 I co QflnD c0_ Q ACTWCD-i CTWWO(WWTWAAW.-_,"A�(TNOWC " OOTTNA0WONO ! *. r-, , 0000000000000000000000 nI— v ^ � !m Y/ NNNNNNNNNNNNNNNNNNNNNN JoOMMOMOOMOOMMM000OOOMOOM0o0O00OO0000000O ` m5 I -n,< . m VVVVVVVJVJVVVVVVVVVVVV '33 ® m N Z Z (n 0 -;m o o O coc00000Oc0c0C0cOCDCOcotoc0co(0000000000c 00000000000000 T m O77 g Q Z ZZ Z Z Z Z ZZ Z Z Z ZZ Z Z Z ZZ Z Z Z O MM can 0000000000000000000000000000000000000000 7 m m 0000000000000000000000 g m O N C _.„0_, ..... _, N���N _,�„ OO M0,3(,)_,- _,w-.4w WW-+_._,A-,_._,A N� 4,-,-.W-,--, WWNCTWCT» Doth-, WW ? < MCT-+CTOWAJCOJ JCDO Oc00CTO00CTOOCTCTOCTCrOCTCTCTOCTOo00CTCT > ro oNCTOCT(r CTMMNMAA OACTMVOAOA > 00 ; C OOinCTOCnOOCTOOCT(TCTOCTOo0oo0000oOp000000000000 @ 000O00ONOCA000O000WO OOCT N m m CO O m u u u u u NN u u u u u u u u u u u u NN u u u u X =-; � Cl) ,1 J_,_,N C WN T< < m o m ;m x�x� x==„„)_„=-.4;4= m ^< Oo00000000000000000000000000000000000000 m m — m ..t0 MMMMMMMOAAOAAAAA00AAAA 0 fl7 OM 3 S 0 ,=777"773 57-._.7==7=7=7777 < C1 O m 0 i^ _= m m x ma X M M m= m o0 0 0 0 00 0 0 0 0 00 0 0 0 00 0 0 0 00 0 0 0 00 0 0 0 0 00 0 0 0 00 0 m V I N NN N N N N N CC j �C 0 X 00 O O O 00 0 0 0 0 00 0 0 0 00 O O O 00 0 0 0 00 O O O O 00 O O O 00 O m 0 O O" V MMMMcOMMMMMMMMMMMMMMMMMMMMMMM(OMCOMCOCDcOMMMCDM C Cl) oj m x���xxxx=x==fi x=x xxx m O Cl) oo .,, 3 0 0 OOOOOOOOOo00OOOOoo000O000000000oo0O00000 0 CD 3 ;x o 00 0 0 0 0 OM M M M MM M M M MM M M M p) CD Cl) a �. j0 7 7 7 7 7 7 7=7 7=7 7 7 7 7 7 7 7 7 7 7 ? am 00 0 o O Oo o O O O 00 O O O 00 O O O o0 O O O 00 O O o O 00 O O O o0 O mm D cn DIVisiiv N NIVtVNN fVNNIViviv NNN .r IVNIVNNIVi..) VNi.. fJ m3 - m D NN WW W W W WW W W W W WW W W W WW W W W WW W W W WW W W W W WW W W W WW W C) CD C) la WCOWWWWW WW WM CD - DC m _,1* 5-555. a ZZZZZZZ3 3 ZZ3 3 ZZ �B. DC i y it m;m aaaanaa0000000aaooa -OO m m II D A N(v N N N N N N N 7 7 7 7 7 7 7 N N==N N 7 7 0.CD 1 11 0000000000000000000000000000000000000000 (7 C, A N2 AAAAA.A C C CD C C C CAA CD CDA.CD CD m O M l VVVVVVJJVVVVVVVVVVVVVVVVVJVVVJVJVVVVVVVV Wu' q N w A (Tcn(Tcncncncncn(Tcncncncnv,(T(Tv,cnv,cncTCTcncnc ththth ,cnv,v,cnv,cn(TCTcnthm o m 0 C CT CTCJ0 . o CT CT CT CT (TCT thth co NN > VI co 0000000000000000000000 Com) Q cn �W I y (�) co v 0 0006000006600000000000 N '= 0.0.aaannaaa0.anaana0.0.nan m • r�' r,�' OOOo000000000000000000000000000000000000 p_ m ,� A j 0000000000000000000000 7 0 0 w 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 v u u • v co (.) i CQ N 0 ORM R405-2017 INFILTRATION # Scope ___.. _._. M.ethQ.d.__ SLA_ _LEM.5.0_ FLA EQLA ACH ACH 50 1 Wholehouse Blower Door 0.000433 4266 234.6 440.6 0.69 7.00 HEATING SYSTEM t # System Type Subtype Efficiency Capacity Block Ducts ✓ 1 Split air source heat pump HSPF:8.2 22.2 kBtu/hr 1 sys#1 2 Split air source heat puma HSPF:8.2 45.5 kBtu/hr 2 sys#2 COOLING SYSTEM 1 # System Type Subtype Efficiency Capacity Air Flow SHR Block .Ducts 1 Split air source heat pump SEER:14.5 22.2 kBtu/hr 740 cfm 0.70 1 sys#1 2 Split air source heat pump SEER:14.0 46.0 kBtu/hr 1400 cfm 0.70 2 sys#2 HOT WATER SYSTEM 1 # System Type Subtype Location EF . Cap Use SetPnt Conservation 1 Gas instantaneous 0.82 0 gal 80 gal 120°F None DUCTS Supply ---- Return--- Air CFM 25 Percent HVAC# vc # Location R-Value Area Location Area Leakage Type Handler Out Leakage QN RLF Heat Cool •-j1 (Default) 6.00 1 1 JSecond Floor 6.0 207 ft2 Second Floor 155 ft2 Default Leakage Second Floor (Default) 2 House 6.0 612 ft2 House 24 ft2 Default Leakage House Default 6.00 2 2 TEMPERATURES Programmable Thermostat: N Ceiling Fans: Cooling [ X ]Jan [ X] Feb [ X] Mar [ X] Apr [ X] May [ X] Jun [ X] Jul [ X] Aug [ X] Sep [ X] Oct [ X] Nov [ X] Dec Heating [ X ]Jan [ X Feb [ X] Mar [ X] Apr X] May [ X Jun X] Jul [ X] Aug X Sep [ X] Oct X Nov [ X Dec Venting [ X ]Jan [ X] Feb [ X] Mar [ X] Apr [ X] May [ X] Jun € X] Jul [ X] Aug € X1 Sep [ X] Oct [ X] Nov [ X] Dec Thermostat Schedule: Florida Building Code,6th Edition Hours Schedule Type (2017) 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Cooling(WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Heating(WD) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 Heating(WEH) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 2018-Oct-17 14:30:36 weightsaft' Comfort Builder by Wrightsoft 18.0.31 RSU03444 Right-Energy®Florida 2017 Section 405.4.1 Compliant Software Page 6 kwza•: .,_. ....„v,,,,,, ...DesktopUulington 3761 Left SW-Lot 2 ABCC.rup Calc=MJ8 Front Door faces:SW FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX = 94 The lower the EnergyPerformance Index, the more efficient the home. 1. New home or addition 1. New(From Plans) 12. Ducts, location& insulation level a. Supply ducts: R 6.0 2. Single-family or multiple-family 2. Single-Family b. Return ducts: R 6.0 c.AHU location: House _ 3. Number of units, if multiple-family 3. 1 13. Cooling systems Capacity 46.0 4. Number of bedrooms 4. 5 a. Split system: SEER 14.50 b. Single package: SEER 5. Is this a worst case?(yes/no) 5. No c. Ground/water source: SEER/COP d. Room unit/PTAC: EER 6. Conditioned floor area (ft2) 6. 3761.00 e. Other: 7. Windows,type and area* 14. Heating systems Capacity 45.5 a. U-Factor: 7a. Dbl,0.340 a. Split system heat pump: HSPF 8.20 b. Solar Heat Gain Coefficient(SHGC): 7b. 0.27 b. Single package heat pump: HSPF c.Area (ft2) 7c. 637.70 c. Electric resistance: COP d. Gas furnace, natural gas: AFUE 8. Skylights e. Gas furnace, LPG: AFUE a. U-Factor: 8a. f. Other: b. Solar Heat Gain Coefficient(SHGC): 8b. 15.Water heating systems 9. Floor type, insulation level a. Electric resistance: EF a. Slab-on-grade(R-value): 9a. 0.0 b. Gas fired, natrual gas: EF 0.820 b.Wood, raised (R-value): 9b. 43.0 c. Gas fired, LPG: EF c. Concrete, raised (R-value) 9c. d. Solar system with tank: EF e. Dedicated heat pump with tank: EF 10 Wall type and insulation: f. Heat recovery unit: HeatRec% a. Exterior: g. Other: 1.Wood frame(Insulation R-value): 10a1. 19 2. Masonry(Insulation R-value): 10a2. 16. HVAC credits claimed (Performance Method) b.Adjacent: a. Ceiling fans: 1. Wood frame(Insulation R-value): 10b1. 13 b. Cross ventilation: 2. Masonry(Insulation R-value): 10b2. c.Whole house fan: d. Multizone cooling credit: Yes 11. Ceiling type and insulation level e. Multizone heating credit: Yes a. Under attic(R-value): 11a. 19.0 f. Programmable thermostat: b. Single assembly(R-value): 11b. 38.0 c. Knee walls/skylight walls(R-value) 11c. d. Radiant barrier installed 11d. *Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise,a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: 6(AP)AirII• Date: k l 31 11. Address of New Home: 1607 Atlantic Beach Dr. City/FL Zip: Atlantic Beach, FL 32233 2018-Oct-17 14:30:36 wrightsof" Comfort Builder by Wrightsoft 18.0.31 RSU03444 Rig ht-En ergy®Florida 2017 Section 405.4.1 Compliant Software Page 7 ,,,,,,. ;, , ,_. ...Desktop\Julington 3761 Left SW-Lot 2 ABCC.rup Calc=MJ8 Front Door faces:SW FORM R405-2017 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 1607 Atlantic Beach Dr. PERMIT#: Atlantic Beach, FL 32233 MANDATORY REQUIREMENTS -See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085,Florida Statues)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.completed and signed by the builder The building official shall verify that the EPL display card accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix RD. • R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. ❑ R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. El R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. El R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. ❑ R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air. Where using tight-fitting doors on factory-built fireplaces listed and labeledin accordance with UL 127,the doors shall be tested and listed for the fireplace. Where using tight-figging doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. ❑ R402.4.3 Fenestration air leakage. Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 L/s/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. W{"19htsoft Comfort Builder by Wrightsoft 18.0.31 RSU03444 Rig ht-Energy Florida 2017 Section 405.4.1 Compliant Software 2018-Oct-17 14:30:36 Page 8 , ...Desktop\Julington 3761 Left SW-Lot 2 ABCC.rup Calc=MJ8 Front Door faces:SW FORM R405-2017 MANDATORY REQUIREMENTS -(Continued) El R402.4.4 Rooms containing fuel-burning appliances In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1.Direct vent apliances with both intake and exhaust pipes installed continuous to the outside. 2.Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. El R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS El R403.1 Controls El R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ▪ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.3.2 Sealing(Mandatory). All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or(7), Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAE 193. El R403.3.3 Duct testing. Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Post construction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure. All registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑ R403.3.5 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. El R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3. El R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance,and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. E3 R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace termperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. El R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for how water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. ❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 2018-Oct-17 14:30:36 wrightso ft-; Comfort Builder by Wrightsoft 18.0.31 RSU03444 Right-Energy® Florida 2017 Section 405.4.1 Compliant Software Page 9 ,,,,,. ...Desktop\Julington 3761 Left SW-Lot 2 ABCC.rup Calc=MJ8 Front Door faces:SW FORM R405-2017 MANDATORY REQUIREMENTS -(Continued) ❑ R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies(Mandatory). ❑ R403.5.6.1 Storage water heater temperature controls. El R403.5.6.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 1 40°F(38°C to 60°C). R403.5.6.1.2 shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. ▪ R403.5.6.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria of Section R403.5.6.2.1. El R403.5.6.2.1 Solar water heating system.Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation,including: Natural,Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. El R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure of for mechanical ventilation shall meet the following criteria: 1.The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2.No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3.If ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19,space permitting,or R-10 otherwise. ❑ R403.7 Heating and cooling equipment(Mandatory). ❑ R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved methodologies,heating and cooling calculation based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY(a) AIRFLOW RATE MAXIMUM CFM CFM/WATT CFM Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt <90 Bathroom, utility room 90 2.8 cfm/watt Any For SI: 1 cfm-28.3 L/min. (a)When tested in accordance HVI Standard 916 2018-Oct-17 14:30:36 wrightsoft" Comfort Builder by Wrightsoft 18.0.31 RSU03444 Right-Energy®Florida 2017 Section 405.4.1 Compliant Software Page 10 ...Desktop\Julington 3761 Left SW-Lot 2 ABCC.rup Calc=MJ8 Front Door faces:SW MANDATORY REQUIREMENTS -(Continued) ▪ R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1.Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2.When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. El R403.7.1.2 Heating equipment capacity. ❑ R403.7.1.2.1 Heat pumps Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. El R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1 El R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. ❑ R403.7.1.3 Extra capacity required for special occasions.Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1.A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2.A variable capacity system sized for optimum performance during base load periods is utilized. O R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provis ions in lieu of Section R403. ❑ R403.9 Snow melt and ice system controls(Mandatory). Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the systemw hen the pavement temperature is above 50°F(10°C),and no precipitation is falling and an automatic or manual control that w ill allow shutoff w hen the outdoor temperature is above 40°F(4.8°C). O R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. ❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. ❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1.Where public health standards require 24-hour pump operations. 2.Pumps that operate solar-and waste-heat-recovery pool heating systems. 3.Where pumps are powered exclusively from on-site renewable generation. ❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. 0 R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 2018-Oct-17 14:30:36 Wrightsof' Comfort Builder by Wrightsoft 18.0.31 RSU03444 Right-Energy® Florida 2017 Section 405.4.1 Compliant Software Page 11 e:.,• - ...Desktop\Julington 3761 Left SW-Lot 2 ABCC.rup Calc=MJ8 Front Door faces:SW MANDATORY REQUIREMENTS-(Continued) El R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. ❑ R403.11 Portable spas(Mandatory).The energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS ▪ R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception: Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. • 2018-Oct-17 14:30:36 4111- vvrightsoft°` Comfort Builder by Wrightsoft 18.0.31 RSU03444 Rig ht-En ergy®Florida 2017 Section 405.4.1 Compliant Software Page 12 ,• ...Desktop\Julington 3761 Left SW-Lot 2 ABCC.rup Calc=MJ8 Front Door faces:SW FORM R405-2017 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Julington 3761 Left SW Builder Name Toll Brothers Inc. Street: 1607 Atlantic Beach Dr. Permit Office: Duval City,State,Zip: Atlantic Beach,FL 32233 Permit Number: Owner: Steve Merten Jurisdiction: 261300 Design Location: FL,Jacksonville/Intnl. COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA 8( General A continuous air barrier shall be installed in the re uirements building envelope.The exterior thermal envelope Air-permeable insulation shall not be used as a q contains a continuous barrier.Breaks or joints in the sealing material. ❑ air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit The insulation in any dropped ceiling/soffit shall be aligned with the insulation and any shall be aligned with the air barrier. gaps in the air barrier shall be sealed. ❑ Access openings,drop down stairs or knee wall doors to unconditioned attics paces shall be sealed. Walls The junction of the foundation and sill plate Cavities with corners and headers of frame walls shall be sealed.The junction of the top plate shall be insulated by completely filling the cavity and the top of exterior walls shall be sealed. with a material having a thermal resistance of R-3 Ell walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier Windows,skylights The space between window/door jambs and framing, and doors and skylights and framing shall be sealed. ❑ Rim joists are insulated and include an air Rim joists shall be insulated. Rim joists barrier. ❑ Floors(including The air barrier shall be installed at any exposed Floor framing cavity Insulation shall be installed above-garage and edge of insulation, to maintain permanent contact with the underside cantilevered floors) of subfloor decking,or floor framing cavity insulation shall be permitted to be in contact ❑ with the top sideof sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space Exposed earth in unvented crawl spaces shall be Where provided in lieu of floor insulation, walls covered with a Class I vapor retarder with insulation shall be permanently attached ❑ overlapping joints taped. to the crawlspace walls. Shafts,penetrations Duct shafts,utility penetrations,and flue shaft openings to exterior or unconditioned space shall ❑ be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that ❑ on installation readily conforms to the available cavity spaces. Garage Air sealing shall be provided between the garage separation and conditioned spaces. ❑ Recessed Recessed light fixtures installed in the building Recessed light fixtures installed in the lighting thermal envelope shall be sealed to the drywall. building thermal envelope shall be air tight ❑ and IC rated. Plumbing and Batt insulation shall be cut neatly to fit around wiring wiring and plumbing in exterior walls,or insulation that on installation readily conforms ❑ to available space shall extend behind piping and wiring. Shower/tub on The air barrier shall be installed behind Exterior walls adjacent to showers and tubs exterior wall electrical or communication boxes or air-sealed shall be insulated. ❑ boxes shall be installed. Electrical/phone The air barrier shall be installed behind ❑ box on exterior electrical or communication boxes or air-sealed walls boxes shall be installed. HVAC register HVAC register boots that penetrate building boots thermal envelope shall be sealed to the subfloor ❑ or drywall. Concealed When required to be sealed,concealed fire sprinklers sprinklers shall only be sealed in a manner that is recommended by the manufacturer. ❑ Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 2018-Oct-17 14:30:36 w rightsoft-, Comfort Builder by Wrightsoft 18.0.31 RSU03444 Right-Energy® Florida 2017 Section 405.4.1 Compliant Software Page 13 , ...DesktopUulington 3761 Left SW-Lot 2 ABCC.rup Calc=MJ8 Front Door faces:SW FORM R405-2017 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: 261300 Permit Number: Job Information Builder: Toll Brothers Inc. Community: Atlantic Beach Country Club Lot: 2 ABCC Address: 1607 Atlantic Beach Unit: City: Atlantic Beach State: FL Zip: 32233 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method. I I PRESCRIPTIVE METHOD The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. The building or dwelling unit shall be tested and verified as having an air leakage rate of not PERFORMANCE or ERI METHOD exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration,sub-section ACH50. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): 7.000 x60= 36566 = Method for calculating building volume: CFM(50) BuildinguiVolume ACH(50) ❑ Retrieved from architectural plans II PASS ❑� Code software calculated n When ACH(50)is less than 3, Mechanical Ventilation installation ❑ Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or and approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 2018-Oct-17 14:30:36 wrightsoft" Comfort Builder by Wrightsoft 18.0.31 RSU03444 Rig ht-En ergy®Florida 2017 Section 405.4.1 Compliant Software Page 14 d.. ...Desktop\Julington 3761 Left SW-Lot 2 ABCC.rup Calc=MJ8 Front Door faces:SW Project Summary Date: Lot 2 ABCC C 41. r� (Rest of House) By: Saidie Guintivano McGowan s Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie©mcgowansac.corn Web:www.mcgowansac.com License:CMC1... Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904) 217-0739 Fax: (904) 814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Notes: JULINGTON Desi•n Information Weather: Jacksonville/Intnl., FL, US Winter Design Conditions Summer Design Conditions Outside db 29 °F Outside db 98 °F Inside db 70 °F Inside db 75 °F Design TD 41 °F Design TD 23 °F Daily range M Relative humidity 50 % Moisture difference 62 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 35155 Btuh Structure 27370 Btuh Ducts 4428 Btuh Ducts 5175 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 39582 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 32544 Btuh Method Blower door Latent Cooling Equipment Load Sizing Shielding/stories 3 (partial)/2 Pressure/AVF 50 Pa/4284 cfm Structure 7078 Btuh Ducts 936 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling • (none) Area(ft2) 2717 2717 Equipment latent load 8014 Btuh Volume(ft') 27170 27170 Air changes/hour 0.54 0.33 Equipment Total Load (Sen+Lat) 40559 Btuh Equiv.AVF (cfm) 243 148 Req. total capacity at 0.70 SHR 3.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB04800GOA0 Cond CH14NB04800GOA0 AHRI ref 9162789 Coil FB4CNP048L AHRI ref 9162789 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 32200 Btuh Heating output 45500 Btu h @ 47°F Latent cooling 13800 Btuh Temperature rise 30 °F Total cooling 46000 Btuh Actual air flow 1400 cfm Actual air flow 1400 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.80 Capacity balance point=28°F Backup: Input= 12 kW, Output=39582 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft 2018-Oct-17 14:33:58 CComfort Builder by Wrightsofl 18.0.31 RSU03444 Page 1 ...DesktopUulington 3761 Left SW-Lot 2 ABCC.rup Calc=MJ8 Front Door faces:SW , „ Project Summary Job: Lot2ABCC Second Floor Bate: r6chwatt-0 By: Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie©mcgowansaccom Web:www.mcgowansac.com License:CMC1... Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904) 217-0739 Fax: (904) 814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Notes: JULINGTON Desi•n Information Weather: Jacksonville/Intnl., FL, US Winter Design Conditions Summer Design Conditions Outside db 29 °F Outside db 98 °F Inside db 70 °F Inside db 75 °F Design TD 41 °F Design TD 23 °F Daily range M Relative humidity 50 % Moisture difference 62 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 15748 Btuh Structure 12444 Btuh Ducts 1764 Btuh Ducts 2083 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 17511 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 14527 Btuh Method Blower door Latent Cooling Equipment Load Sizing Shielding/stories 3 (partial)/2 Pressure/AVF 50 Pa/4284 cfm Structure 5062 Btuh Ducts 420 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling • (none) Area(ft2) 1044 1044 Equipment latent load 5482 Btuh Volume (ft3) 9396 9396 Air changes/hour 1.10 0.67 Equipment Total Load (Sen+Lat) 20009 Btuh Equiv.AVF (cfm) 173 105 Req.total capacity at 0.70 SHR 1.7 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB02400G0A0 Cond CH14NB0240000A0 AHRI ref 9162301 Coil FB4CNP025L AHRI ref 9162301 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14.5 SEER Heating input Sensible cooling 15540 Btuh Heating output 22200 Btuh @ 47°F Latent cooling 6660 Btuh Temperature rise 27 °F Total cooling 22200 Btuh Actual air flow 740 cfm Actual air flow 740 cfm Air flow factor 0.042 cfm/Btuh Air flow factor 0.051 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.73 Capacity balance point=26°F Backup: Input=6892 kW, Output=23516038 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrlghtsoft'- 2018-Oct-17 14:33:58 Comfort Builder by Wrightsoft 18.0.31 RSU03444 Page 2 ...DesktopUulington 3761 Left SW-Lot 2 ABCC.rup Calc=MJ8 Front Door faces:SW 4.6 A First Floor master bed - dining 12x6 12x6 14x14 12x6 7" 7„ 12" _ 7„ 0•410•41 r P•41 _ Al 448 10x6 "F.n • attic 12 x 6 access 7" 00 great room *0 mas-r bath kitchen • 12" master wic 6 x 12 14" 7" NC NJ • ■ 12" - 3"Fan 16" ■ OM12x6 II 10 x 6" 4x8 6 x 10 . 4" P-ntry 5' 10 x 10 .4� laundry'', 6„ ■ 18" 10x10 • 400,• ' 12 x 6 study ahu 24 x 18 18" 4n y stairs/foyer 7" 10" 12 x 12 _ r9 14x140 ,,,8x4 • 4" 8x4 "Fan garage, 4" IP P9v$ann, e �2 wic 2 J 4x8 bath rJ 4' 12 x 12 10' Imo/ 14 x 6 8" bed 2 4 Job#: Lot 2 ABCCMcGowan's Heating & Air Conditioning Scale: 1 : 108 Performed by Saldie Guintivano for: Page 1 Steve Merten 11320 E.Phillips Parkway Dr. Comfort Builder by Wrightsoft 160 Cape May Ave. Jacksonville,FL 32256 Ponte Vedra,Fl 32081 18.0.31 RSU03444 Phone:(904)217-0739 Fax:(904)814-8173 Phone:904-278-0339 Fax:904-278-0366 2018-Oct-17 14:34:42 www.tollbrothers.com smerten@tollbrothersinc.com www.mcgowansac corn Saldie@mcgowansac.com on 3761 Left SW-Lot 2 ABCC rup _4/ . „ ..,.. up bed 4 ah open to below 12 x 12 12x6 12x12FA9" 7"111 10" In ... ipi 14" bonus rmt4" 2-way 12 x 6. attic • ks wic 4 12x6: 7" � 12x6 .8x4 711 ;,ems " 8x4 4^ 7 p .. 4., 8x vij PNff@l3 •12" 4,. 8 x 4 /' gallery q r/ :th 3 12x12 14x6 10" 8,. bed 3 • Job#: Lot 2 ABCCMcGowan's Heating & Air Conditionin Scale: 1 : 108 Performed by Saldie Guintivano for: Page 2 Steve Merten 11320 E.Phillips Parkway Dr. Comfort Builder by Wrightsoft 160 Cape May Ave. Jacksonville,FL 32256 18.0.31 RSU03444 Ponte Vedra,Fl 32081 Phone:904-278-0339 Fax:904-278-0366 2018-Oct-17 14:34:42 Phone:(904)217-0739 Fax:(904)814-8173 www.tollbrothers.com smerten@tollbrothersinc.com www.mcgowansac.com saldie@mcgowansac.com ...on 3761 Left SW-Lot 2 ABCC.rup Manual S Compliance Report Job: Lot 2ABCC Date: A.fi � � (Rest of House) By: Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax.904-278-0366 Email:saldie@mcgowansac.corn Web:www.mcgowansac.corn License:CMC1... Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Cooling Equipment Design Conditions Outdoor design DB: 98.0°F Sensible gain: 32544 Btuh Entering coil DB: 75.7°F Outdoor design WB: 80.1°F Latent gain: 8014 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 40559 Btuh Indoor RH: 50% Estimated airflow: 1400 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH 14NB04800G0A0+FB4CNP048L Actual airflow: 1400 cfm Sensible capacity: 33036 Btuh 102%of load Latent capacity: 8895 Btuh 111%of load Total capacity: 41931 Btuh 103%of load SHR: 79% Heating Equipment Design Conditions Outdoor design DB: 29.4°F Heat loss: 39582 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH 14NB04800GOAO+FB4CNP048L Actual airflow: 1400 cfm Output capacity: 34306 Btuh 87%of load Capacity balance: 28 °F Supplemental heat required: 5277 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1400 cfm Output capacity: 11.6 kW 100%of load Temp. rise: 27 °F Meets all requirements of ACCA Manual S. 434- wrightsoft- 2018-Oct-17 14:33:58 Comfort Builder by Wrightsoft 18.0.31 RSU03444 Page 1 AC ...DesktopUulington 3761 Left SW-Lot 2 ABCC.rup Calc=MJ8 Front Door faces:SW eta Manual S Compliance Report Job: Lot2ABCC r Second Floor Bate: itir.rf+li ait �� By: Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie©mcgowansac.com Web:www.mcgowansac.com License:CMC1... Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Cooling Equipment Design Conditions Outdoor design DB: 98.0°F Sensible gain: 14527 Btuh Entering coil DB: 75.7°F Outdoor design WB: 80.1°F Latent gain: 5482 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 20009 Btuh Indoor RH: 50% Estimated airflow: 740 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH 14NB02400G0A0+FB4CNP025L Actual airflow: 740 cfm Sensible capacity: 15540 Btuh 107%of load Latent capacity: 6660 Btuh 121%of load Total capacity: 22200 Btuh 111%of load SHR: 70% Heating Equipment Design Conditions Outdoor design DB: 29.4°F Heat loss: 17511 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH 14NB02400G0A0+FB4CNP025L Actual airflow: 740 cfm Output capacity: 22200 Btuh 127%of load Capacity balance: 26 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 740 cfm Output capacity: 6891.9 k1, 4290%of load Temp. rise: 85k °F Meets all requirements of ACCA Manual S. %V*°19htgp ft• 2018-Oct-17 14:33:58 Comfort Builder by Wrighlsoff 18.0.31 RSU03444 Page 2 AC ...Desktop\Julington 3761 Left SW-Lot 2 ABCC.rup Calc=MJ8 Front Door faces:SW Duct System Summary Dae Lot2ABCC iffsAgVttti (Rest of House) By: Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie@mcgowansac.cow Web:www.mcgowansac.com License:CMC1... Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904) 814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.334/0.056 in H2O 0.334/0.056 in H2O Lowest friction rate 0.093 in/100ft 0.093 in/100ft Actual air flow 1400 cfm 1400 cfm Total effective length(TEL) 421 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk bath 2 c 57 0 2 0.096 4.0 Ox 0 VIFx 83.7 265.0 st7 bed 2 h 5909 209 172 0.093 8.0 Ox 0 VIFx 91.2 270.0 st7 dining-A h 6264 222 195 0.127 7.0 Ox 0 VIFx 63.1 200.0 st5 great room c 2896 85 125 0.137 7.0 Ox 0 VIFx 43.8 200.0 st5 great room-A c 2896 85 125 0.134 7.0 Ox 0 VIFx 49.7 200.0 st5 kitchen c 2765 107 119 0.131 7.0 Ox 0 VIFx 56.2 200.0 st5 laundry c 1903 41 82 0.194 5.0 Ox 0 VIFx 32.7 140.0 st2 master bath h 3068 109 94 0.130 6.0 Ox 0 VIFx 47.0 210.0 st8 master bed h 3808 135 106 0.129 7.0 Ox 0 VIFx 53.5 205.0 st8 master bed-A h 3808 135 106 0.131 7.0 Ox 0 VIFx 50.5 205.0 st8 masterwic c 238 7 10 0.204 4.0 Oxo VIFx 23.7 140.0 st2 pantry h 628 22 8 0.109 4.0 Ox 0 VIFx 72.7 235.0 st6 pwdr h 1056 37 25 0.093 • 4.0 Ox 0 VIFx 99.2 260.0 st7 stairs/foyer c 2495 80 107 0.191 6.0 Ox 0 VIFx 35.1 140.0 st2 study c 2149 69 92 0.107 7.0 Ox 0 VIFx 76.7 235.0 st6 we h 545 19 16 0.132 4.0 Ox 0 VIFx 48.9 205.0 st8 wic 2 h 1068 38 14 0.096 4.0 Ox 0 VIFx 82.7 265.0 st7 - - wrightsoft" 2018-Oct-1714:33:58 ,_ Comfort Builder by Wrightsoft 18.0.31 RSU03444 Page 1 A ...DesktopUulington 3761 Left SW-Lot 2 ABCC.rup Calc=MJ8 Front Door faces:SW Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st5 Peak AVF 875 878 0.093 821 14.0 0 x 0 VinIFIx st4 st7 Peak AVF 284 214 0.093 521 10.0 0 x 0 VinIFIx st6 st6 Peak AVF 376 315 0.093 478 12.0 0 x 0 VinIFIx st5 st8 Peak AVF 397 323 0.129 506 12.0 0 x 0 VinIFIx st4 st4 Peak AVF 1272 1201 0.093 911 16.0 0 x 0 VinIFIx st2 st2 . Peak AVF 1400 1400 0.093 792 18.0 0 x 0 VinIFIx Return Branch Detail Table Grille Htg Cig TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb4 Ox 0 1400 1400 60.0 0.093 792 18.0 Ox 0 VIFx wrigihtsoft° 2018-Oct-17 14:33:58 "^"�� ...,. ....._._. Comfort Builder by Wrightsoft 18.0.31 RSU03444 Page 2 L.P. ...DesktopUulington 3761 Left SW-Lot 2 ABCC.rup Calc=MJ8 Front Door faces:SW 774, 1 Duct System Summary Job: Lot 2ABCC Date: � 1Sic"�l�d'�ftfrJ � `-'4 Second Floor By: Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie©rncgowansac.corn Web:www.mcgowansac.com License:CMC1... Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904) 814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Heating Cooling External static pressure 0.50 In H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.211 /0.179 in H2O 0.211 /0.179 in H2O Lowest friction rate 0.105 in/100ft 0.105 in/100ft Actual air flow 740 cfm 740 cfm Total effective length (TEL) 373 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk b.wic h 123 5 4 0.157 4.0 Ox 0 VIFx 9.0 125.0 st1 bath 3 c 258 12 13 0.112 4.0 Ox 0 VIFx 33.3 155.0 st3 bed 3 c 3336 168 170 0.106 8.0 Ox 0 VIFx 38.4 160.0 st3 bed 4-A c 2557 121 130 0.105 7.0 Ox 0 VIFx 41.2 160.0 st3 bonus rm. c 2769 133 141 0.157 7.0 Ox 0 VIFx 9.4 125.0 st1 bonus rm.-A c 2769 133 141 0.147 7.0 Ox 0 VIFx 18.2 125.0 st1 open to below h 2833 120 101 0.149 7.0 Ox 0 VIFx 16.2 125.0 st1 sinks c 237 11 12 0.108 4.0 Ox 0 VIFx 35.2 160.0 st3 wic 3 h 473 20 14 0.106 4.0 Ox 0 VIFx 38.1 160.0 st3 wic 4 h 433 18 13 0.105 4.0 Ox 0 VIFx 40.6 160.0 st3 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 349 352 0.105 448 12.0 0 x 0 VinIFIx st1 st1 Peak AVF 740 740 0.105 692 14.0 0 x 0 VinIFIx w r llgh tsoft` 2018-Oct-17 14:33:58 Comfort Builder by Wrightsoft 18.0.31 RSU03444 lr Page 3 ..Desktop\Julington 3761 Left SW-Lot 2 ABCC.rup Calc=MJ8 Front Door faces:SW Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox 0 206 197 170.7 0.105 379 10.0 Ox 0 VIFx rt2 rsb6 Ox 0 143 155 171.5 0.105 352 9.0 Ox 0 VIFx rt2 rb2 Ox 0 391 388 108.0 0.166 717 10.0 Ox 0 VIFx ill Return Trunk Detail Table Trunk Htg CIg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 Peak AVF 740 740 0.105 692 14.0 0 x 0 VinIFlx rt2 Peak AVF 349 352 0.105 448 12.0 0 x 0 VinIFlx rt1 wrigihtsoft' 2018-Oct-17 14:33:58 ti .. Comfort Builder by Wrightsoft 18.0.31 RSU03444 Page 4 ACOA ...DesktopUulington 3761 Left SW-Lot 2 ABCC.rup Calc=MJ8 Front Door faces:SW