359 PLAZA - ROW JEA rsrL'f;" RIGHT OF WAY PERMIT PERMIT NUMBER
J �`r CITY OF ATLANTIC BEACH ROW18-0042
800 SEMINOLE ROAD ISSUED: 11/30/2018
ATLANTIC BEACH FL33 22 EXPIRES: 2/28/2019
3
MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts, state agencies,or federal agencies.
JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK:
RIGHT OF WAY SINGLE OR TWO
359 PLAZA FAMILY RIGHT OF WAY replace poles in right-of-way $0.00
TYPE OF REAL ESTATE ZONING: BUILDING USE SUBDIVISION:
CONSTRUCTION: NUMBER: GROUP:
170010 0000 ATLANTIC BEACH
COMPANY: ADDRESS: CITY: STATE: ZIP:
Jacksonville Electric
Authority 21 W. Church Street Jackonville FL 32202
OWNER: ADDRESS: CITY: STATE: ZIP:
RAISER VIRGINIA S 359 PLAZA ATLANTIC BEACH FL 32233-5441
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
LIST OF CONDITIONS
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
1 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL
Notes:
All runoff must remain on-site during construction.
2 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL
Notes:
Full right-of-way restoration,including sod,is required.
Issued Date: 11/30/2018 1 of 2
1LAty',,, RIGHT OF WAY PERMIT PERMIT NUMBER
t'6ROW 18-0042
CITY OF ATLANTIC BEACH
00 800 SEMINOLE ROAD ISSUED: 11/30/2018
` ATLANTIC BEACH FL 32233EXPIRES: 2/28/2019
3 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL
Notes:
Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field
coordination is needed,call 247-5878.
4 PUBLIC UTILITIES UTILITY MAP INFORMATIONAL
Notes:
See attached Utility Map.
DESCRIPTION I ACCOUNT QUANTITY PAID AMOUNT
TOTAL:
Issued Date: 11/30/2018 2 of 2
r1.r::;1;, City of Atlantic BeachRAPPLICATION NUMBER
Building Department (To be assigned by the Building Department.)
i 800 SeminoleRoad NOV �0t,u 7 , DOy4
J
�' Atlantic
Beach, Florida 32233-5445 � 2018
\\ Phone(904)247-5826 • Fax(904)24 5
j;ti9� E-mail: building-dept@coab.us :— Date routed la
g
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: J T� T" t Department review required Yes No
Building
Applicant: J E A Planning &Zoning
Tree Administrator
Project: C, Q\QL. t. Pbk4 S f\ r c Gr lit F- Og ,Public Works 7
1 `ltc ‘,/ Public Utilities
Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St. Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: proved. ❑Denied. ❑Not applicable
(Circle one.) Comments:
BUILDING
PLANNING & ZONING A� • !7'�fii
Reviewed b � /�/i� _� , ., . ate:
TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ['Approved as revised. ❑Denied. ❑Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
rjrlyr�� City of Atlantic Beach APPLICATION NUMBER
�1 '� � Building Department (To be assigned by the Building Department.)
A 800 Seminole Road flECEJVE4' Atlantic Beach, Florida 32233-5445 l� A - D0(14,
Phone(904)247-5826 • Fax(904)24
%_p;t19� E-mail: building-dept@coab.us NOV 2 7 2018 Date routed: I la
City web-site: http://www.coab.us
BY:
APPLICATION REVIEW AND TRACKING FORM
Property Address: S-61 P ( q Department review required Yes No
Building
Applicant: A Planning &Zoning
Tree Administrator
Project: c L Q\J c ()0\ S l ( � _C Ii c$ Publicork
_ s
1 �� ‘,/ C Public Utilities,
Public Safety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLIC N STATUS
Reviewing Department First Review: pproved. ['Denied. ENot applicable
(Circle one.) Comments:
BUILDING
PLANNING &ZONING Date: /1 -Z �1
Reviewed by: 8
TREE ADMIN. Second Review: ❑Approved as rev. ed. ['Denied. ['Not applicable
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ['Denied. ['Not applicable
Comments:
Reviewed by: Date:
Revised 05/19/2017
RIGHT-OF-WAY/ EASEMENT PERMIT APPLICATION **ALL INFORMATION
City of Atlantic Beach HIGHLIGHTED IN GRAY IS
800 Seminole Road, Atlantic Beach, FL 32233 REQUIRED.
PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES
Job Address 361 PLAZA — C1 C;SE....SA ZtttilI L, LS MS`t P(li pDA)—
l Permit Number t 17
0 D ya
Contractor Information
Company JEA Qualifying Agent
Address 21 WEST CHURCH ST. City JACKSONVILLE State FL Zip 32202
Phone Email
State Certification/Registration#
Architect Phone Email
Engineer R. SIMPSON Phone 665-7793 Email SIMPRB@JEA.CPM
Workers Compensation Insurer OR Exempt❑Expiration Date
• Permittee declares that prior to filing this application they have ascertained the location of all existing utilities, both aerial
and underground and the accurate locations are shown on the sketches.
• Whenever necessary for the construction, repair, improvement, maintenance,safe and efficient operation, alteration or
relocation of all,or any portion of said street or easement as determined by the Public Works Director,any or all said poles,
wires, pipes, cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said
street or easement or reset or relocated hereon as required by the Public Works Director and at the expense of the
Permittee unless reimbursement is authorized.
• All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the
supervision of R.SIMPSON (Project Superintendent)
with (Company Name) JEA Phone
• All materials and equipment shall be subject to inspection by the Public Works Director.
• All city property shall be restored to its original condition as far as practical, in keeping with City specifications and the
manner satisfactory to the City.
• A sketch of plans covering details of this installation, as well as a copy of a recent survey shall be made a part of this permit.
Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with
this application.
• The permittee shall commence actual construction in good faith within 60 days. If the beginning date is more than 60
days from date of permit approval then permittee must review the permit with the Public Works Director to make sure no
changes have occurred in the area that would affect the permitted construction,
• It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right,
title and interest in the land to be entered upon and used by the holder,and the holder will,at all times, assume all risk of
and indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss, damage and cost of
expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges.
• The Public Works Director shall be notified 24 hours prior to starting work and again immediately upon completion.
Date
Permittee(signed in presence of Notary Public)
STATE OF FLORIDA,COUNTY OF DUVAL
The foregoing instrument was acknowledged this _day of ,20 ,
by ,who personally appeared before me and
(printed name of Permittee)
acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it.
[ ]Personally Known
Signature of Notary Public,State of Florida [ ] Produced Identification(Type)
H:\Applications&Forms\Word Documents\201801001 Right-of-Way Easement Permit Application.docx Revision Date:10/1/18
g a ,
M '!�r l '$"j� . M .. , a
i* i .. * ` y try _ M Myri '�
,. :t .. 3 y t '.- �. PLAZA DR '� :,-
..,--.idieris ill ,
-
, :::'#1'
a ft+ •,,,.c�K�F;, a _ f `. - - -- "}e.
'Ct 10
"k
' 4 " ' .4 ', #lop. ., ., ,
' .y C.Y.
e. :+YA‘,---.'„4../4:244,-,f
'. •
, 4
-4 n.
_ 1
..;eilailki '.-- 1.r
H
y
'• k * « e 4..1:411
*
. r ,,,,,,,,, . .10'
Yu ��
F rMR .ti ,wadr 5 `� Yl ayj
{4, #—
aQii,-)11• • 3' feW a
•
ill — ,
,'
• ct. �ali
CO
T
,
! •
4 #
'rill 4x
0a 41,
z
' '
r .•4 8, W . .4';''
19i1 fid :
,' ' -1,,,,,,, ilk. '- 44,000,,:'ii...4 ..,,',ilfri :,
T '
f I i ` I C })
P is
•
, yA. 4
_,
.. +
Ff ' 'F 1!"!
ra"c ,,. _._ .- --- �'�,max i. ..410r*' xig3t1 itpv.,„ , .,.
•
a . 2
i
ENGINEERING DESIGN
ORACLE PERMIT MAXIMO DATE REL
PROJECT#: 35599 N.O.: 8005212 WO#: 30360433 CONST: 11/15/18
CIR. TREE TRIMMING
SUB-STA: NEPTUNE BEACH N.O.: 563 REQ'D:NO
CELL
ENGINEER: Robert Simpson N.O.: N/A ZIP CODE: N/A
CUSTOMER/ SVC PHONE
LOCATION: 361 PLAZA/POLE REPLACEMENT 563 CENTER: SSSC N.O.:665-7793
STA 1. P# 361 PLAZA/ R&R 45/3W, INSTALLN- -- - --
C
25KVA, RUN 4/OP TO STA 2. qi, 1 2T
- STA 2, P# 360 PLAZA./ R&R 35/4W. 2T T
***** LANE CLOSURE REQUIRED *****
♦ 1
1/OT 348 42 ♦ 4
4 4
4
346 340 336 334
1
4
354 350 343 337
4 376 372 364 358 355 1 349 ♦ 4
380 369 363 359 ♦
5 377 371 14 4
375 STA 14/0T
♦ \ T 1/oT
\ 1/0T 1/0T UM
1/OT n ui
1/OT1\t11.) 11-1W •
T T O J T •_ 4/OP
tI1 r 4/OP C -
•
2 • 0 4�.0 PLAZA N�-- - -
'-�
OP
4CU N 4/OP
- --- - - - 0: • ---- �.
o r,IA 1/OT
.____- -
1 a
STA 2 1/OT
1/OT 1/OT
♦ ♦ ♦
1 338
♦ 352 348 344
354 350 341
�,SSHERRY DR 2 3S8 347 ♦
4 - 374 1i+0a�"""�. 359-1 345
378 371 365 359
4
JE1 CUE Reports
Estimate Number:35599 361 PLAZA/45/3W POLE Estimate Type:SR Contract:089-16-HM OH FY19
REPLACEMENT
Estimate Version: By: SIMPRB
MWO#/Task:30360433 Required Date:
Oracle Project#:8005212 Estimated On: 10/26/2018
Cost Estimate
Materials JEA Contractor
1.New Material Cost(w/sales tax) $1,648.69 $1,648.69
2.Transformer Cost(w/sales tax) $1,028.37 $1,028.37
3.Returned Material Salvage Value $0.00 $0.00
Labor
4.Crew Time $1,369.09 $3,773.72
5. Extraordinary Costs $0.00 $0.00
JEA Overhead
6.Fringe Benefits(54.56%of lines 4&7) $899.42 $277.13
7.Engineering Costs(Variable%of line 4) $279.40 $507.94
8.Project Equipment Costs(40%of total equipment costs) $809.92 $0.00
9.Material Handling(8.30%of lines 1 &2) $222.20 $222.20
10.Inspection(6.84%of line 4) $0.00 $258.12
11.Total Cost of Project $6,257.08 $7,716.18
12.Work Order Estimate(Line 11 minus line 8,9,& 10) $5,224.97 $7,493.98
13. Billable Equipment Depreciation(60%of total equipment costs) $1,214.87 $0.00
14.Billing Estimate(Including Transformer Cost)(Lines 11 + 13+(58.71%of 4&7)) $8,439.78 $8,014.39
15.Billing Estimate(W/O Transformer Cost)(Lines 11 + 13+(58.71%of 4&7)-Line 2) $7,411.41 $6,986.02
Time Estimate
Crew Hours Total Manhours
10.98 43.91
.41E1 CUE Reports
Estimate Number: 35599 361 PLAZA/45/3W POLE Estimate Type:SR Contract:089-16-HM OH FY19
REPLACEMENT
Estimate Version: By: SIMPRB
MWO#/Task:30360433 Required Date:
Oracle Project#:8005212 Estimated On: 10/26/2018
CU Detail
•
Station: 01 361 PLAZA
Build Transfer Remain in Place Remove
C.4/0P 125
DA1F-5 1
DA1 F-5`2 1
DGAC 1
DGAC*25 1
G1W*2 1
P.45/3W 1
RUBUP 4
S2OES*2/0-1/0 3
S20ES*4/0-4/0 1
C.1/0T 125
CUT 3
DEYE 2
NUMBER 1
P.45/3W 1
PIN 1
POLECON 4
PRIINS 1
RUBDOWN 4
SEC 2
SECINS 2
SMWEDGE 4
STANDOFF 1
TANGENT 2
WOODGRD 1
Station: 2 360 PLAZA
Build Transfer Remain in Place Remove
G3W*2 1
GY3-A`5 2
P.35/4W 1
S2OES*4/0-1/0 2
S4*4/0 1
S9*1/0 2
SEVP 1
1 CUE Reports
Estimate Number:35599 361 PLAZA/45/3W POLE Estimate Type:SR Contract:089-16-HM OH FY19
REPLACEMENT
Estimate Version: By: SIMPRB
MWO#/Task:30360433 Required Date:
Oracle Project 4:8005212 Estimated On: 10/26/2018
CUT 3
DEYE 2
DOWN3/8 2
NUMBER 1
P.35/4W 1
POLECON 2
SMWEDGE 2
TANGENT 1
WOODGRD 1
JE1 CUE Reports
Estimate Number:35599 361 PLAZA/45/3W POLE Estimate Type:SR Contract:089-16-HM OH FY19
REPLACEMENT
Estimate Version: By: SIMPRB
MWO#fTask:30360433 Required Date:
Oracle Project#:8005212 Estimated On: 10/26/2018
Material Summary
Item Quantity Item Number Item Description
2 ARRLI003 ARRESTER, LIGHTNING, 18 KV, DISTRIBUTION CLASS AND RISER
POLE (MOV)WITHOUT MOUNTING BRACKET, 15.2/26.4Y NOMINAL
VOLTAGE
2 BKTAC009 BRACKET, ARRESTER AND CUTOUT, FIBERGLASS WITH RAYCHEM
MATERIAL OVER ROD TYPE: SINGLE PHASE
2 BKTFS001 BRACKET, FIBERGLASS STANDOFF, 2" FIBERGLASS ROD, 18"
STANDOFF TO INS BASE ROD COVERED WITH RAYCHEM HEAT-
SHRINK MATERIAL, DUCTILE IRON FITTINGS
2 BOLDA015 BOLT, 3/4"X 14", DOUBLE ARMING, GALV. WITH 4 SQUARE NUTS
ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25
EACH)
2 BOLMS020 BOLT, MACHINE, 5/8"X 14", SQUARE HEAD GALVANIZED STEEL,
W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX
QUANTITIES OF 50 EACH)
7 BOLMS035 BOLT, MACHINE, 3/4"X 12", SQUARE HEAD GALVANIZED STEEL,
W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX
QUANTITIES OF 25 EACH)
2 BOLMS036 BOLT, MACHINE, 3/4"X 14", SQUARE HEAD GALVANIZED STEEL,
W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX
QUANTITIES OF 25 EACH)
125 CAIOS003 CABLE, 4/0-19 (PAP), OVERHEAD SERVICE DROP, 600 VOLT
MULTIPLEX CABLE "VICKSBURG" PRE-ASSEMBLED PARALLEL 1000
FOOT REELS
2 CLAGROO1 CLAMP, GROUND ROD, 5/8" -4SOL "HAMMERLOCK"
1 CLASR002 CLAMP, STRAIN RELIEF WEDGE, ALUMINUM, 1/0 TRI -4/0 PAP
5 CLASR003 CLAMP, STRAIN RELIEF WEDGE MESSENGER, SIZE: #6- 2/0
1 CLASS006 CLAMP, STRAIGHT STRAIN, ALUMINUM, 10000# 3/0 - 556 ALUM (STD
PKG 15 EA)
2 CLATG001 CLAMP, TRANSFORMER TANK GROUND, "BRONZE"6 SOL - 1 STR.
6 CNNCP002 CONNECTOR, #2, 6-2 MAIN, 2-1/0 TAP, ALUMINUM COMPRESSION,
PARALLEL TAP,
10 CNNCP004 CONNECTOR, #4, 1/0-2/0 MAIN, 1/0-3/0 TAP COMPRESSION,
PARALLEL TAP, ALUMINUM,
3 CNNCP005 CONNECTOR, #3, 6-2 MAIN, 2/0-3/0 TAP, COMPRESSION, PARALLEL
TAP, ALUMINUM,
4 CNNCP006 CONNECTOR, #6, 1/0-2/0 MAIN, 3/0-4/0 TAP COMPRESSION,
PARALLEL TAP, ALUMINUM,
3 CNNCP007 CONNECTOR, #7, 3/0-4/0 MAIN, 3/0-4/0 TAP COMPRESSION,
PARALLEL TAP, ALUMINUM,
2 CNNCP008 CONNECTOR, #5, 6-2 MAIN, 4/0 TAP, COMPRESSION, PARALLEL TAP,
ALUMINUM,
2 CNNGROO2 COUPLING, GROUND ROD, "THREADLESS" REMARKS: FOR
THREADLESS GROUND RODS
3 CNNTS009 CONNECTOR, CONTAMINATED ENVIRONMENT, TRANSFORMER
SECONDARY SET SCREW TYPE WITH INHIBITOR, 1/2" STUD, RANGE:
12-350, 6-PORTS.
` � CUE Reports
Estimate Number:35599 361 PLAZA/45/3W POLE Estimate Type:SR Contract:089-16-HM OH FY19
REPLACEMENT
Estimate Version: By: SIMPRB
MWO#/Task:30360433 Required Date:
Oracle Project#:8005212 Estimated On: 10/26/2018
8 CNNV0003 CONNECTOR, 6-2 SOL/10-2 SOL, VISE GRIP PARALLEL, BRONZE
72 COBC0028 CONDUCTOR, #4 SOLID, SOFT DRAWN, BARE COPPER, 200', 25#, ON
PLASTIC REEL, 4" X 11.5" W/2" HOLE
140 COBCW014 CONDUCTOR, #4, TYPE 40 DSA, COPPERWELD & COPPERWELD-
COPPER .204" DIAMETER 1480# BREAKING STRENGTH ( 50# COIL-
427' )
20 COVIC002 COVER, "D" DIE, INSULATING, 2-1/2"
2 CUTOT006 CUTOUT, CONTAMINATED ENVIRONMENT, 26" LEAKAGE DISTANCE
TO GROUND, 100A, 27 KV, 170 KV BIL (54 EA PER PALLET)
1 FUSOH022 FUSE, OVERHEAD DISTRIBUTION, 1.6 AMP, TRANSFORMER
2 GUAGW001 GUARD, GROUND WIRE, 1/2"X 1/2" X 96", GRAY PLASTIC
2 GUAGW002 GUARD, "YELLOW", GUY WIRE, 1/4"TO 1/2"8', POLYETHYLENE, USED
ON ALL 3/8" AND 7/16" GUY STRANDS (DISTRIBUTION)
2 GUYAT008 GUY HOOK, COMBINATION, MALLEABLE OR DUCTILE IRON, HOT DIP
GALV. 13/16" MOUNTING HOLE, 20,000 LB MIN. ULT. STRENGTH. FOR
WOOD OR CONCRETE POLES
4 GUYGROO1 GRIP, GUY, 3/8", 26", GALVANIZED
100 GUYST005 STRAND, GUY, 3/8" DIA, 7 PER STRAND, GALVANIZED STEEL, CLASS
"B" GALV. OR BEZINOL IS ACCEPTABLE (500' COIL)
2 INSGB002 INSULATOR, STRAIN, GUY BREAKER, 21,000# RATED, 60" ROD
LENGTH, FIBERGLASS FOR USE ON JEA'S DISTRIBUTION SYSTEM
ONLY
1 INSS0002 INSULATOR, SUSPENSION, 4", CLASS 52-9 NEMA STRENGTH 10000#,
GALV. FITTINGS
2 INSVP001 INSULATOR, VERTICAL POST, TIE TOP 35-KV, 3/4" STUD TAP
STANDARD PACKAGING IS NOT TO EXCEED THREE UNITS OR 72
POUNDS.
4 NUTSL003 NUT, LOCK, SQUARE, 5/8" HOLE SIZE, HOT DIPPED GALVANIZED
4 NUTSLOO4 NUT, LOCK, SQUARE, 3/4" BOLT SIZE, HOT DIPPED GALVANIZED
1 POLW0003 POLE, WOOD, 35' CLASS 4 (T/L = 44), WEIGHT=1,026 LBS
1 POLW0006 POLE, WOOD, 45' CLASS 3 (T/L = 26), WEIGHT=1,770 LBS
4 RODGR003 ROD, GROUND, THREADLESS, 5/8" X 8', SHIP ON OPEN FLATBED
ONLY!
2 SLEAL003 SLEEVE, RED TO RED NEUTRAL 2-2 ALUMINUM TRIPLEX NEUTRAL
SPLICING
2 STULI001 STUD, LINE POST, DIA. SHANK- 3/4", SHANK LENGTH- 1-3/4",
GALVANIZED STEEL W/NUTS AND WASHERS; 3/4" HEAD SIZE
2 TAGH0007 ALUMINUM VERTICAL TAG HOLDER FOR ADHESIVE BACK
CHARACTERS((NOT FOR "SLIDE IN" CHARACTERS)). 19.5" HIGH X 2"
WIDE WITH 3-1/8" NAIL HOLES @ THE TOP AND THE BOTTOM. (PKG.
OF 50 EACH)
1 TIEPROO1 TIE, PREFORMED LINE, #2 AAAC, 23" MIN. LENGTH, "F" NECK, SIDE
TIE .316"-.357" COND. RANGE
1 TRAC0001 TRANSFORMER, 25 KVA, 14760/25565Y VOLT PRIMARY, 120/240 VOLT
SECONDARY, SINGLE PHASE, CONTAMINATED ENVIRONMENT
4 WASRD004 WASHER, ROUND, 5/8" BOLT SIZE X 1 3/4" DIAMETER, GALVANIZED,
650 EA P/BOX)
19 WASRD005 WASHER, ROUND, 3/4" BOLT SIZE X 2" DIAMETER, GALVANIZED, "'
500 EACH PER BOX"`
CUE Reports
Estimate Number:35599 361 PLAZA/45/3W POLE Estimate Type:SR Contract:089-16-HM OH FY19
REPLACEMENT
Estimate Version: By: SIMPRB
MWO#/Task:30360433 Required Date:
Oracle Project#:8005212 Estimated On: 10/26/2018
11 WASSF003 WASHER, SQUARE FLAT, 3" SQ X 1/4", 5/8"X 3/4" BOLT SIZE,
GALVANIZED
7 WASSP002 WASHER, SPRING, 3/4" BOLT SIZE, DOUBLE COIL HELICAL TYPE,
GALVANIZED (EXTRA HEAVY DUTY)
JIE
1 CUE Reports
Estimate Number:35599 361 PLAZA/45/3W POLE Estimate Type:SR Contract:089-16-HM OH FY19
REPLACEMENT
Estimate Version: By: SIMPRB
MWO#/Task:30360433 Required Date:
Oracle Project#:8005212 Estimated On: 10/26/2018
CU Summary
CU Name Quantity Description
C.4/0P 125 4/0 AAC PAP W/4/0 AAAC NEUTRAL
DA1 F-5*2 1 2 TANGENT TO 10 DEGREE ANGLE-UNSHIELDED, CONTAMINATED
DGAC*25 1 TRANS; CI, 26.4KV 120/240 25KVA
G1W*2 1 WOOD POLE- EQUIPMENT GROUND
G3W*2 1 WOOD POLE- NON-EQUIPMENT GROUND
GY3-A"5 2 3/8" DOWNGUY WITHOUT ANCHOR
P.35/4W 1 35 FT. CLASS 4 WOOD POLE
P.45/3W 1 45 FT. CLASS 3 WOOD POLE
RUBUP 4 LINE RUBBER INSTALLATION, PER SECT.
S20ES*2/0-1/0 3 S20ES*2/0-1/0
S20ES*4/0-1/0 2 SECONDARY CONNECTION AT POLE
S20ES*4/0-4/0 1 SECONDARY CONNECTION AT POLE
S4*4/0 1 SECONDARY DEADEND
S9*1/0 2 SECONDARY SPLICE
SEVP 1 SEVERE COND. FOR POLE SETTING CREW
CU Name Quantity Description
C.1/0T 125 1/0 TRIPLEX
CUT 6 CUT POLE OR CROSSARM
DEYE 4 S6 REMOVAL
DOWN3/8 2 3/8 IN. DOWNGUY REMOVAL
NUMBER 2 POLE TAG REMOVAL
P.35/4W 1 35 FT. CLASS 4 WOOD POLE
P.45/3W 1 45 FT. CLASS 3 WOOD POLE
PIN 1 INSULATOR PIN REMOVAL
POLECON 6 S20 REMOVAL
PRIINS 1 PRIMARY INSULATOR REMOVAL
RUBDOWN 4 LINE RUBBER REMOVAL, PER SECT.
SEC 2 SEC. SPOOL INS. BRACKET REMOVAL
SECINS 2 SEC. INSULATOR REMOVAL
SMWEDGE 6 SMALL SEC. WEDGE CLAMP REMOVAL
STANDOFF 1 PRI. INSULATOR STANDOFF BRACKET REMOVAL
TANGENT 3 S7 REMOVAL
WOODGRD 2 WOOD POLE NON-EQUIP. GRD REMOVAL