569 TIMBER BRIDGE LN - REV 10-31-18 OFFICE COPY �4 ;,�, CITY OF ATLANTIC BEACH p _v5: 800 Seminole Road , Atlantic Beach,Florida 32233 41;JFi� V REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Sir? 10/31/2018 R �P:=: I X 0 Date Revision to Issued Permit Corrections to Comments Permit# Project Address 569 Timber Bridge Lane Contractor/Contact Name Audrey Regnier Phone 904.595.5243Email aregnier@tollbrothers.com Description of Proposed Revision/Corrections: Permit Fee D $ St). O d Revised ecaics to reflect changes made during installation Additional Increase in Building Value $ Additional S.F. By si ning below,I Audrey Regnier affirm the Revision is inclusive of the proposed changes. (printed name) 10/31/2018 S n ure of Con actor/Ag nt(Con ctor must sign if increase in valuation) Date (Office Use Only) Approved 4 Denied Not Applicable to Department Revision/Plan Review Comments Go rJ Jac / -/° is K -v Cop„ gpat Department Review Required: Building Planning & Zoning Reviewed By Tree Administrator Public Works p� Public Utilities /J /r?—/O Public Safety Date Fire Services FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Cumberland 2796 Right S Builder Name: Toll Brothers Street: Lot 159 Atlantic Beach CC Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL 32233 Permit Number: Owner: Toll Brothers Jurisdiction: 261300 Design Location: FL,Jacksonville NAS County: Duval(Florida Climate Zone 2) 1.New construction or existing New(From Plans) 9. Wall types (3306 ft') Insulation(R) Area(ft') 2.Single family or multiple family Single-Family a. Frm wall,vnl ext,3/8"wood sht 19.0 2906.36 b. Frm wall,stucco ext,r-13 cav i 13.0 400.00 3.Number of units,if multiple family 1 c. N/A 4.Number of bedrooms 4 d. N/A 10. Ceiling types (2320 ft') Insulation(R) Area(ft') 5.Is this a worst case? No a. Attic ceiling,asphalt shingles 19.0 415.38 6. Conditioned floor area above grade (ft') 2796.00 b. Attic ceiling,asphalt shingles 38.0 1904.88 Conditioned floor area below grade(ft') 0 c. N/A Windows 303 ft' Descri tion Area ft' 11.Ducts R Area(ft') 7. ( ) p ( ) a.Sup:House,Ret:House,AH:House 6.0 708.13 a.U-Factor: Dbl,0.340 302.83 b. SHGC: 0.27 b.U-Factor: 12.Cooling systems kBtu/hr Efficiency SHGC: a.Split air source heat pump 47.0 SEER:16.0 c.U-Factor: b. SHGC: 13.Heating systems kBtu/hr Efficiency d.U-Factor: a.Split air source heat pump 46.5 HSPF:9.0 SHGC: b. Area Weighted Average Overhang Depth: 3.944 ft 14.Hot water systems Area Weighted Average SHGC: 0.270 a.Gas instantaneous(0 gal) Cap:0 gal EF:0.82 8. Floor types(2320.25 ft') Insulation(R) Area(ft') b.Conservation features a. Bg floor,light dry soil,on gra 0.0 2212.75 (None) b. FIr floor,frm flr,6"thkns,ca 43.0 107.50 c. N/A 15.Credits Cool Roof Glass/Floor area: 0.104 Total Proposed Modified Loads: 60.95 PASS cS Total Baseline Loads: 69.99 I�M�7 I hereby certify that the plans and specifications covered by Review of the plans and specifications „NEIL'ST, this calculation are in compliance with the Florida Energy covered by this calculation indicates 0.,,,,;------,..,4t' "-,. compliance with the Florida Energy .....„.4., .^• Code. y / Code. Before construction is completed, 741 .- = ' n - 4^ n this buildingwill be inspected for a r?'" " " 0 PREPARED BY: (�rMc(ll'�1 ,2?^ ' t� �IYr� � P it'-''''''i �,,,_.,'r' compliance with Section 553.908 �� DATE: 10/31/18 Florida Statutes. +a __ .:4. I hereby certify that this building,as designed, is in `f'1,--',....,a,# 00,''':4‘/- CO'''''''7"'-i:0). compliance with the Florida Energy Code. /� -.)-,... ..)%,..E...„00- - OWNER/AGENT: BUILDING OFFICIAL: PI DATE: DATE: ii-1- I r -Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50(R402.4.1.2). -Compliance requires a roof absorptance test and roof emittance test in accordance with R405.7.2. REVISION BP# R ie-'C�/b� DATE /I /A / / R SIGNED -{-�I, 2018-Oct-31 05:34:17 P - wrightsoft Comfort Builder by Wrightson 18.0.31 RSU12270 Right-Energy®Florida 201 7 Section 405.4.1 Compliant Software Page 2 ,,:.,. .. ...ktop\Cumberland Bonus 2796 Right Lot 159 AB.rup Calc=MJ8 Front Door faces: S FORM R405-2017 Building Input Summary Report PROJECT Title: Cumberland 2796 Right S Bedrooms: 4 Address type: Street address Building Type: FLAsBuilt Bathrooms: 3 Lot#: Lot 159 ABCC Owner: Toll Brothers Conditioned Area: 2796 Block/Subdivision: Atlantic Beach Country CI Jb #of Units: 1 Total Stories: 2 Platbook: Builder Name: Toll Brothers Worst Case: No Street: Lot 159 Atlantic Bea Permit Office: Atlantic Beach Rotate Angle: 0 County: Duval Jurisdiction: 261300 Cross Ventilation: No City, State,Zip: Atlantic Beach, FL 32233 Family Type: Single-Family Whole House Fan: No New/Existing: New(From Plans) Terrain: Suburban Year Construct:2018 Shielding: Suburban Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville NAS FL_Jacksonville-Cr 2 34 99 70 75 995 60 Medium BLOCKS # Name Area Volume 1 House 2910.63 ft2 28408.38 ft3 SPACES # Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 m.wic 101.50 ft2 1015.00 ft' No 0 0 1 Yes Yes Yes 2 master 265.00 ft2 2650.00 ft' No 2 1 1 Yes Yes Yes 3 study 168.75 ft' 1687.50 ft3 No 0 0 1 Yes Yes Yes 4 foyer 107.50 ft2 1075.00 ft' No 0 0 1 Yes Yes Yes 5 dining 162.00 ft2 1620.00 ft' No 0 0 1 Yes Yes Yes 6 kitchen 216.38 ft2 2163.75 ft' Yes 0 0 1 Yes Yes Yes 7 bed 2 153.13 ft2 1531.25 ft' No 1 1 1 Yes Yes Yes 8 bath 2 46.75 ft' 467.50 ft3 No 0 0 1 Yes Yes Yes 9 m.bath 68.25 ft2 682.50 ft3 No 0 0 1 Yes Yes Yes 10 hall 66.63 ft2 666.25 ft' No 0 0 1 Yes Yes Yes 11 bed 3 181.25 ft2 1812.50 ft3 No 1 1 1 Yes Yes Yes 12 laundry 72.00 ft2 720.00 ft3 No 0 0 1 Yes Yes Yes 13 stairs up 71.13 ft' 640.13 ft3 No 0 0 1 Yes Yes Yes 14 bed 4 214.50 ft2 1930.50 ft3 No 1 1 1 Yes Yes Yes 15 bath 3 67.50 ft2 607.50 ft' No 0 0 1 Yes Yes Yes 16 wic 24.75 ft2 222.75 ft3 No 0 0 1 Yes Yes Yes 17 stairs 67.00 ft2 670.00 ft3 No 0 0 1 Yes Yes Yes 18 pan 14.88 ft2 148.75 ft' No 0 0 1 Yes Yes Yes 19 family room 476.25 ft2 4762.50 ft' No 0 0 1 Yes Yes Yes 20 we 45.50 ft2 455.00 ft' No 0 0 1 Yes Yes Yes 21 A/H 15.75 ft' 141.75 ft' No 0 0 1 Yes Yes Yes 22 loft 304.25 ft' 2738.25 ft' No 0 0 1 Yes Yes Yes FLOORS (Total Exposed Area=2320 sq.ft.) I # Floor Type Space Perimeter R-Value Area U-Factor Tile Wood Carpet 1 Bg floor,light dry soil,on grade depth m.wic 22 ft 0 101.50 ft' 0.989 0 1.0 0 t 2 Bg floor,light dry soil,on grade depth master 28 ft 0 265.00 ft2 0.989 0 1.0 0 3 Bg floor,light dry soil,on grade depth study 29 ft 0 168.75 ft2 0.989 0 1.0 0 I 4 Bg floor,light dry soil,on grade depth foyer 5 ft 0 107.50 ft2 0.989 0 1.0 0 I 5 Bg floor,light dry soil,on grade depth dining 12 ft 0 162.00 ft2 0.989 0 1.0 0 1 6 Bg floor,light dry soil,on grade depth kitchen 9 ft 0 216.38 ft2 0.989 0 1.0 0 i 7 Bg floor,light dry soil,on grade depth bed 2 14 ft 0 153.13 ft' 0.989 0 1.0 0 6 8 Bg floor,light dry soil,on grade depth bath 2 0 ft 0 46.75 ft2 0.989 0 1.0 0 9 Bg floor,light dry soil,on grade depth m.bath • 0 ft 0 68.25 ft' 0.989 0 1.0 0 10 Bg floor,light dry soil,on grade depth hall 0 ft 0 66.63 ft2 0.989 0 1.0 0 11 Bg floor,light dry soil,on grade depth bed 3 15 ft 0 181.25 ft2 0.989 0 1.0 0 12 Bg floor,light dry soil,on grade depth laundry 0 ft 0 72.00 ft2 0.989 0 1.0 0 13 FIr floor,frm flr,6"thkns,carpet fir fnsh,r- bed 4 13 ft 43 65.00 ft2 0.049 0 0 1.0 14 Fir floor,frm fir,6"thkns,carpet flr fnsh,r- bath 3 4 ft 43 37.50 ft2 0.049 0 0 1.0 15 Fir floor,frm flr,6"thkns,carpet flr fnsh,r- wic 1 ft 43 5.00 ft2 0.049 0 0 1.0 16 Bg floor,light dry soil,on grade depth stairs • 0 ft 0 67.00 ft2 0.989 0 1.0 0 17 Bg floor,light dry soil,on grade depth pan 4 ft 0 14.88 ft2 0.989 0 1.0 0 18 Bg floor,light dry soil,on grade depth family room 39 ft 0 476.25 ft2 0.989 0 1.0 0 19 Bg floor,light dry soil,on grade depth we 7 ft 0 45.50 ft2 0.989 0 1.0 0 2018-Oct-31 05:34:17 414- wr ightsoftt Comfort Builder by Wrighlsoft 18.0.31 RSU12270 Rig ht-En ergy®Florida 2017 Section 405.4.1 Compliant Software Page 3 ,,,,.:•::i.,,=.::,.:..,E..,., ...ktop\Cumberland Bonus 2796 Right Lot 159 AB.rup Calc=MJ8 Front Door faces: S FORM R405-2017 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch 1 # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed RoofAsph 2514 ft2 483 ft2 Dark 0.75 Yes 0.90 Yes 0 23 2 Gable or shed RoofAsph 384 ft2 74 ft2 Dark 0.75 Yes 0.90 Yes 0 23 ATTIC # __ Type Ventilation Vent_Ratio 1 in Area RBS IRCC .� 1 Full attic Vented .300 2320.25ft2 N N 2 Full attic Vented 300 354.75 ft2 N N CEILING (Total Exposed Area=2320 sq.ft.) # Ceiling Type Space R-Value U-Factor Area Framing Fraction Truss Type 1 Attic ceiling,asphalt shingles roof m.wic 19 0.049 10.50 ft2 0.10 - 2 Attic ceiling,asphalt shingles roof m.wic 38 0.026 91.00 ft2 0.10 - 3 Attic ceiling,asphalt shingles roof master 19 0.049 13.88 ft2 0.10 - 4 Attic ceiling,asphalt shingles roof master 38 0.026 251.13 ft2 0.10 - 5 Attic ceiling,asphalt shingles roof study 19 0.049 14.25 ft2 0.10 - 6 Attic ceiling,asphalt shingles roof study 38 0.026 154.50 ft2 0.10 - 7 Attic ceiling,asphalt shingles roof foyer 19 0.049 2.50 ft2 0.10 - 8 Attic ceiling,asphalt shingles roof foyer 38 0.026 65.00 ft2 0.10 - 9 Attic ceiling,asphalt shingles roof dining 19 0.049 2.00 ft2 0.10 - 10 Attic ceiling,asphalt shingles roof dining 38 0.026 52.00 ft2 0.10 - 11 Attic ceiling,asphalt shingles roof kitchen 19 0.049 2.00 ft2 0.10 - 12 Attic ceiling,asphalt shingles roof kitchen 38 0.026 68.00 ft2 0.10 - 13 Attic ceiling,asphalt shingles roof bed 2 19 0.049 7.00 ft2 0.10 - 14 Attic ceiling,asphalt shingles roof bed 2 38 0.026 146.13 ft2 0.10 -- 15 Attic ceiling,asphalt shingles roof bath 2 38 0.026 46.75 ft2 0.10 -- 16 Attic ceiling,asphalt shingles roof m.bath 38 0.026 68.25 ft2 0.10 -- 17 Attic ceiling,asphalt shingles roof hall 38 0.026 66.63 ft2 0.10 -- 18 Attic ceiling,asphalt shingles roof bed 3 19 0.049 1.50 ft2 0.10 -- 19 Attic ceiling,asphalt shingles roof bed 3 38 0.026 36.00 ft2 0.10 - 20 Attic ceiling,asphalt shingles roof stairs up 19 0.049 8.75 ft2 0.10 -- 21 Attic ceiling,asphalt shingles roof stairs up 38 0.026 62.38 ft2 0.10 -- 22 Attic ceiling,asphalt shingles roof bed 4 19 0.049 20.75 ft2 0.10 -- 23 Attic ceiling,asphalt shingles roof bed 4 38 • 0.026 193.75 ft2 0.10 -- 24 Attic ceiling,asphalt shingles roof bath 3 19 0.049 3.75 ft2 0.10 -- 25 Attic ceiling,asphalt shingles roof bath 3 38 0.026 63.75 ft2 0.10 -- 26 Attic ceiling,asphalt shingles roof wic 19 0.049 2.25 ft2 0.10 -- 27 Attic ceiling,asphalt shingles roof wic 38 0.026 22.50 ft2 0.10 -- 28 Attic ceiling,asphalt shingles roof stairs 38 0.026 1.63 ft2 0.10 -- 29 Attic ceiling,asphalt shingles roof family room 19 0.049 18.75 ft2 0.10 -- 30 Attic ceiling,asphalt shingles roof family room 38 0.026 457.50 ft2 0.10 -- 31 Attic ceiling,asphalt shingles roof wc 19 0.049 3.25 ft2 0.10 -- 32 Attic ceiling,asphalt shingles roof wc 38 0.026 42.25 ft2 0.10 -- 33 Attic ceiling,asphalt shingles roof A/H 38 0.026 15.75 ft2 0.10 -- 34 Attic ceiling,asphalt shingles roof loft 19 0.049 304.25 ft2 0.10 • 2018-Oct-31 05:34:17 wrghtsofitr Comfort Builder by wrightsoft 18.0.31 RSU12270 Right-Energy®Florida 2017 Section 405.4.1 Compliant Software Page 4 etrE,,,-k„,;.:..F;;,:>.;,,;:., ...ktop\Cumberland Bonus 2796 Right Lot 159 AB.rup Calc=MJ8 Front Door faces: S FORM R405-2017 WALLS (Total Exposed Area=3306 sq.ft.) V. # Adjacent Cavity Width Height Sheathing U- Frm. Solar Below Ornt To Wall Type Space R-Value Ft In Ft In Area R-Value Factor Frac. Absor. Grade% 1 N Exterior Frm wall,vn ext m.wic 19 7 0 10 0 70.0 ft2 0 0.068 0.25 0.75 0 2 E Exterior Frm wall,vn ext m.wic 19 14 6 10 0 145.0 ft2 0 0.068 0.25 0.75 0 3 N Exterior Frm wall,vn ext master 19 18 0 10 0 180.0 ft2 0 0.068 0.25 0.75 0 4 W Exterior Frm wall,vn ext master 19 10 0 10 0 100.0 ft2 0 0.068 0.25 0.75 0 5 E Exterior Frm wall,vn ext study 19 3 0 10 0 30.0 ft2 0 0.068 0.25 0.75 0 6 S Exterior Frm wall,vn ext study 19 13 6 10 0 135.0 ft2 0 0.068 0.25 0.75 0 7 W Exterior Frm wall,vn ext study 19 12 6 10 0 125.0 ft2 0 0.068 0.25 0.75 0 8 S Exterior Frm wall,vn ext foyer 19 5 0 10 0 50.0 ft2 0 0.068 0.25 0.75 0 9 - Partition Frm wall,stucco foyer 13 18 6 10 0 185.0 ft2 0 0.091 0.25 0.75 0 10 W Exterior Frm wall,vn ext dining 19 12 0 10 0 120.0 ft2 0 0.068 0.25 0.75 0 11 W Exterior Frm wall,vn ext kitchen 19 8 6 10 0 85.0 ft2 0 0.068 0.25 0.75 0 12 E Exterior Frm wall,vn ext bed 2 19 14 0 10 0 140.0 ft2 0 0.068 0.25 0.75 0 13 E Exterior Frm wall,vn ext bed 3 19 14 6 10 0 145.0 ft2 0 0.068 0.25 0.75 0 14 - Partition Frm wall,stucco bed 3 13 12 6 10 0 125.0 ft2 0 0.091 0.25 0.75 0 15 - Partition Frm wall,stucco laundry 13 9 0 10 0 90.0 ft2 0 0.091 0.25 0.75 0 16 N Exterior Frm wall,vn ext stairs up 19 9 0 9 0 81.0 ft2 0 0.068 0.25 0.75 0 17 NE Exterior Frm wall,vn ext stairs up 19 0 8 9 0 6.4 ft2 0 0.068 0.25 0.75 0 18 E Exterior Frm wall,vn ext stairs up 19 3 6 9 0 31.5 ft2 0 0.068 0.25 0.75 0 19 W Exterior Frm wall,vn ext stairs up 19 4 0 9 0 36.0 ft2 0 0.068 0.25 0.75 0 20 N Exterior Frm wall,vn ext bed 4 19 13 0 9 0 117.0 ft2 0 0.068 0.25 0.75 0 21 E Exterior Frm wall,vn ext bed 4 19 16 6 9 0 148.5 ft2 0 0.068 0.25 0.75 0 22 S Exterior Frm wall,vn ext bed 4 19 13 0 9 0 117.0 ft2 0 0.068 0.25 0.75 0 23 S Exterior Frm wall,vn ext bath 3 19 7 6 9 0 67.5 ft2 0 0.068 0.25 0.75 0 24 S Exterior Frm wall,vn ext wic 19 4 6 9 0 40.5 ft2 0 0.068 0.25 0.75 0 25 W Exterior Frm wall,vn ext pan 19 4 0 10 0 40.0 ft2 0 0.068 0.25 0.75 0 26 N Exterior Frm wall,vn ext family room 19 15 0 10 0 150.0 ft2 0 0.068 0.25 0.75 0 27 W Exterior Frm wall,vn ext family room 19 24 0 10 0 240.0 ft2 0 0.068 0.25 0.75 0 28 E Exterior Frm wall,vn ext we 19 6 6 10 0 65.0 ft2 0 0.068 0.25 0.75 0 29 N Exterior Frm wall,vn ext loft 19 17 6 9 0 157.5 ft2 0 0.068 0.25 0.75 0 • 30 S Exterior Frm wall,vn ext loft 19 15 0 9 0 135.0 ft2 0 0.068 0.25 0.75 0 31 W Exterior Frm wall,vn ext loft 19 16 6 9 0 148.5 ft2 0 0.068 0.25 0.75 0 DOORS (Total Exposed Area =45 sq.ft.) Width Height # Ornt Door Type Space Storms U-Value Ft In Ft In Area v' •1 S Door,wd sc type foyer • None 0.390 3 0 8 0 24.0 ft2 2 N Door,wd sc type foyer None 0.390 2 8 8 0 21.3 ft2 WINDOWS (Total Exposed Area=303 sq.ft.) Wall Overhang Interior l # Ornt ID Frame Panes NFRC U-Factor SHGC Storms Area Depth Separation Shade Screening 1 N 3 Viny Low-E Double Yes 0.340 0.27 No 30.0ft2 2 ft 0 in 1 ft 0 in None indoor 2 S 6 Viny Low-E Double Yes 0.340 0.27 No 30.0ft2 7 ft 0 in 1 ft 0 in None indoor 3 W 7 Viny Low-E Double Yes 0.340 0.27 No 15.0ft2 2 ft 0 in 1 ft 0 in None indoor 4 W 10 Viny Low-E Double Yes 0.340 0.27 No 30.0ft2 2 ft 0 in 1 ft 0 in None indoor 5 E 12 Viny Low-E Double Yes 0.340 0.27 No 15.0ft2 2 ft 0 in 1 ft 0 in None indoor 6 E 13 Viny Low-E Double Yes 0.340 0.27 No 15.0ft2 2 ft 0 in 1 ft 0 in None indoor 7 E 21 Viny Low-E Double Yes 0.340 0.27 No 15.0ft2 2 ft 0 in 1 ft 0 in None indoor 8 N 26 TIM Low-E Double Yes 0.340 0.27 No 24.Oft2 10 ft 0 in 1 ft 0 in None indoor 9 N 26 Viny Low-E Double Yes 0.340 0.27 No 30.8ft2 10 ft 0 in 1 ft 0 in None indoor 10 W 27 Viny Low-E Double Yes 0.340 0.27 No 45.0ft2 2 ft 0 in 1 ft 0 in None indoor 11 E 28 Viny Low-E Double Yes 0.340 0.27 No 8.0ft2 2 ft 0 in 1 ft 0 in None indoor 1? W 31 Vinv I ow-F Double Yes 0.340 0.27 No 45.Oft2 2 ft 0 in 1 ft 0 in None indoor GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation - 1 462 ft2 462ft2 46 ft 10 ft 13 INFILTRATION # Scope Method SLA CFM 50_ LLA EqLA ACH ACH 50 1 Wholehouse Blower Door 0.000453 3314 182.3 342.3 0.68 7.00 HEATING SYSTEM J # System Type Subtype_-_ Efficiency Capacity Block Ducts_ 1 Split air source heat pump HSPF:9.0 46.5 kBtu/hr 1 sys#1 COOLING SYSTEM 7 # System TYee Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Split air source heat pump SEER:16.0 47.0 kBtu/hr 1567 cfm 0.70 1 sys#1 2018-Oct-31 05:34:17 wrightsofr Comfort Builder by Wrightsoft 18.0.31 RSU12270 Right-Energy®Florida 2017 Section 405.4.1 Compliant Software Page 5 ,uti:w,z.;v«,....:,.,,.1::;.:.,,.y ...ktop\Cumberland Bonus 2796 Right Lot 159 AB.rup Calc=MJ8 Front Door faces: S FORM R405-2017 HOT WATER SYSTEM 1 # System Type Subtype Location EF Cap Use SetPnt Conservation 1 Gas instantaneous 0.82 0 gal 70 gal 120°F None DUCTS — Supply -- Return--- Air CFM 25 Percent HVAC# I. # Location R-Value Area Location Area Leakage Type Handler Out Leakage QN RLF Heat Cool 1 House 6.0 708 ft2 House 0 ftz Default Leakage House (Default) 6.00 1 1 TEMPERATURES Programmable Thermostat: N Ceiling Fans: Cooling [ X ]Jan [ X] Feb [ X] Mar [ X] Apr [ X] May [ X] Jun [ X] Jul [ X] Aug [ XSep [ X] Oct [ X] Nov [ X] Dec Heating [ X ]Jan [ X] Feb [ X] Mar [ X) Apr [ X] May [ X] Jun [ X] Jul [ X] Aug [ X] Sep [ X] Oct [ X] Nov [ X] Dec Venting [ X ]Jan [ X] Feb [ X] Mar [ X] Apr [ X] May [ X] Jun [ X] Jul [ X] Aug [ X] Sep [ X] Oct [ X] Nov [ X] Dec Thermostat Schedule: Florida Building Code,6th Edition Hours Schedule Type (2017) 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Cooling(WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Heating(WD) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 Heating(WEH) AM 72 72 72 72 72 72 72 72 72 72 72 72 PM 72 72 72 72 72 72 72 72 72 72 72 72 • • • 2018-Oct-31 05:34:17 wrightsoft Comfort Builder by Wrighisoft 18.0.31 RSU12270 Right-Energy®Florida 2017 Section 405.4.1 Compliant Software Page 6 k4,44,..4;4. .. , ...ktop\Cumberland Bonus 2796 Right Lot 159 AB.rup Calc=MJ8 Front Door faces: S FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX = 87 The lower the EnergyPerformance Index, the more efficient the home. 1. New home or addition 1. New(From Plans) 12. Ducts, location & insulation level a. Supply ducts: R 6.0 2. Single-family or multiple-family 2. Single-Family b. Return ducts: R c.AHU location: House 3. Number of units, if multiple-family 3. 1 13. Cooling systems Capacity 47.0 4. Number of bedrooms 4. 4 a. Split system: SEER 16.00 b. Single package: SEER 5. Is this a worst case?(yes/no) 5. No c. Ground/water source: SEER/COP d. Room unit/PTAC: EER 6. Conditioned floor area (ft2) 6. 2796.00 e. Other: 7.Windows, type and area* 14. Heating systems Capacity 46.5 a. U-Factor: 7a. Dbl, 0.340 a. Split system heat pump: HSPF 9.00 b. Solar Heat Gain Coefficient(SHGC): 7b. 0.27 b. Single package heat pump: HSPF c.Area (ft2) 7c. 302.83 c. Electric resistance: COP d. Gas furnace, natural gas: AFUE 8. Skylights e. Gas furnace, LPG: AFUE a. U-Factor: 8a. f. Other: b. Solar Heat Gain Coefficient(SHGC): 8b. 15.Water heating systems 9. Floor type, insulation level a. Electric resistance: EF a. Slab-on-grade (R-value): 9a. 0.0 b. Gas fired, natrual gas: EF 0.820 b. Wood, raised (R-value): 9b. 43.0 c. Gas fired, LPG: EF c. Concrete, raised (R-value) 9c. d. Solar system with tank: EF e. Dedicated heat pump with tank: EF 10 Wall type and insulation: f. Heat recovery unit: HeatRec% a. Exterior: g. Other: 1.Wood frame(Insulation R-value): 10a1. 19 2. Masonry (Insulation R-value): 10a2. 16. HVAC credits claimed (Performance Method) b. Adjacent: a. Ceiling fans: 1.Wood frame(Insulation R-value): 10b1. 13 b. Cross ventilation: 2. Masonry(Insulation R-value): 10b2. c.Whole house fan: d. Multizone cooling credit: 11. Ceiling type and insulation level e. Multizone heating credit: a. Under attic(R-value): 11a. 19.0 f. Programmable thermostat: b. Single assembly(R-value): 11b. 38.0 c. Knee walls/skylight walls (R-value) 11c. d. Radiant barrier installed 11 d. *Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: • Address of New Home: Lot 159 Atlantic Beach CC City/FL Zip: Atlantic Beach, FL 32233 2018-Oct-31 05:34:17 41- virightsoft Comfort Builder by Wrightsoft 18.0.31 RSU12270 Rig ht-Energy Florida 2017 Section 405.4.1 Compliant Software Page 7 klop\Cumberland Bonus 2796 Right Lot 159 AB.rup Calc=MJ8 Front Door faces: S FORM R405-2017 • Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: Lot 159 Atlantic Beach CC • PERMIT#: Atlantic Beach, FL 32233 MANDATORY REQUIREMENTS -See individual code sections for full details. SECTION R401 GENERAL I El R401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085,Florida Statues)requires the EPL display card to be included as an addendum to each sales contract for both presold and . nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.completed and signed by the builder The building official shall verify that the EPL display card accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix RD. El R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. El R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. El R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the man ufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air. Where using tight-fitting doors on factory-built fireplaces listed and labeledin accordance with UL 127,the doors shall be tested and listed for the fireplace. Where using tight-figging doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. El R402.4.3 Fenestration air leakage. Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. • 2018-Oct-31 05:34:17 4111- wrlghtsofte Comfort Builder by Wrightsoft 18.0.31 RSU12270 Right-Energy®Florida 2017 Section 405.4.1 Compliant Software Page 8 ...ktop\Cumberland Bonus 2796 Right Lot 159 AB.rup Calc=MJ8 Front Door faces: S FORM R405-2017 MANDATORY REQUIREMENTS -(Continued) El R402.4.4 Rooms containing fuel-burning appliances In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1.Direct vent apliances with both intake and exhaust pipes installed continuous to the outside. 2.Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS El R403.1 Controls El R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. El R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. El R403.3.2 Sealing(Mandatory). All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or(7), Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. El R403.3.2.1 Sealed air handler.Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design air flow rate when tested in accordance with ASHRAE 193. n R403.3.3 Duct testing. Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Post construction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure. All registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑ R403.3.5 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3. E3 R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance,and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. El R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace termperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. U R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall be dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for how water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. El R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 2018-Oct-31 05:34:17 wrtghtsoft Comfort Builder by VJrightsoft 18.0.31 RSU12270 Right-Energy®Florida 2017 Section 405.4.1 Compliant Software Page 9 , ., .,..rr ...ktop\Cumberland Bonus 2796 Right Lot 159 AB.rup Calc=MJ8 Front Door faces: S FORM R405-2017 MANDATORY REQUIREMENTS -(Continued) Di R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ED R403.5.6 Water heater efficiencies(Mandatory). R403.5.6.1 Storage water heater temperature controls. • R403.6.6.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). El R403.5.6.1.2 shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. El R403.5.6.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria of Section R403.5.6.2.1. • R403.5.6.2.1 Solar water heating system.Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation,including: Natural,Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. • R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. El R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure of for mechanical ventilation shall meet the following criteria: 1.The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2.No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3.If ventilation air is drawn from enclosed spaces(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum or R-19,space permitting,or R-10 otherwise. R403.7 Heating and cooling equipment(Mandatory). • R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved methodologies,heating and cooling calculation based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY(a) AIRFLOW RATE MAXIMUM CFM CFM/WATT CFM Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom, utility room 10 1.4 cfm/watt < 90 Bathroom,utility room 90 2.8 cfm/watt Any For SI: 1 cfm-28.3 Umin. (a)When tested in accordance HVI Standard 916 2018-Oct-31 05:34:17 wrliC,j('tsof s Comfort Builder by VJrightsoft 18.0.31 RSU12270 Rig ht-En ergy®Florida 2017 Section 405.4.1 Compliant Software page 10 Ws:.. ...klop\Cumberland Bonus 2796 Right Lot 159 AB.rup Calc=MJ8 Front Door faces: S MANDATORY REQUIREMENTS -(Continued) El R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1.Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2.When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. EJ R403.7.1.2 Heating equipment capacity. El R403.7.1.2.1 Heat pumps Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. ❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1 El R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. El R403.7.1.3 Extra capacity required for special occasions.Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1.A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2.A variable capacity system sized for optimum performance during base load periods is utilized. El R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provis ions in lieu of Section R403. El R403.9 Snow melt and ice system controls(Mandatory). Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the systemw hen the pavement temperature is above 50°F(10°C),and no precipitation is falling and an automatic or manual control that w ill allow shutoff w hen the outdoor temperature is above 40°F(4.8°C). El R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. El R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. • Exceptions: 1.Where public health standards require 24-hour pump operations. 2.Pumps that operate solar-and waste-heat-recovery pool heating systems. 3.Where pumps are powered exclusively from on-site renewable generation. El R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 2018-Oct-31 05:34:17 wrightsoft" Comfort Builder by Wrightsoft 18.0.31 RSU12270 Rig ht-En ergy®Florida 2017 Section 405.4.1 Compliant Software Page 11 ,,,, ...ktop\Cumberland Bonus 2796 Right Lot 159 AB.rup Calc=MJ8 Front Door faces: S MANDATORY REQUIREMENTS -(Continued) R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. UR403.11 Portable spas(Mandatory).The energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception: Low-voltage lighting. Ei R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. • • 2018-Oct-31 05:34:17 - wrightsotft Comfort Builder by Wrightsoft 18.0.31 RSU12270 Rig ht-En orgy OO Florida 2017 Section 405.4.1 Compliant Software Page 12 •, ...ktop\Cumberland Bonus 2796 Right Lot 159 AB.rup Calc=MJ8 Front Door faces: S FORM R405-2017 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Cumberland 2796 Right S Builder Name Toll Brothers Street: Lot 159 Atlantic Beach CC Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL 32233 Permit Number: Owner: Toll Brothers Jurisdiction: 261300 Design Location: FL,Jacksonville NAS COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA Nei General A continuous air barrier shall be installed in the pp requirements building envelope.The exterior thermal envelope Air-permeable ir- er mable insulation shall not be used as a ❑ 4 contains a continuous barrier.Breaks or joints in the 9 air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit The insulation in any dropped ceiling/soffit shall be aligned with the insulation and any shall be aligned with the air barrier. gaps in the air barrier shall be sealed. ❑ Access openings,drop down stairs or knee wall doors to unconditioned attics paces shall be sealed. Walls The junction of the foundation and sill plate Cavities with corners and headers of frame walls shall be sealed.The junction of the top plate shall be insulated by completely filling the cavity and the top of exterior walls shall be sealed. with a material having a thermal resistance of R-3 ❑ Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier Windows,skylights The space between window/door jambs and framing, and doors and skylights and framing shall be sealed. ❑ Rim joists are insulated and include an air Rim joists shall be insulated. ❑ Rim joists barrier. Floors(including The air barrier shall be installed at any exposed Floor framing cavity Insulation shall be installed above-garage and edge of insulation. to maintain permanent contact with the underside cantilevered floors) of subfloor decking,or floor framing cavity insulation shall be permitted to be in contact ❑ with the top sideof sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space Exposed earth in unvented crawl spaces shall be Where provided in lieu of floor insulation, walls covered with a Class I vapor retarder with insulation shall be permanently attached ❑ overlapping joints taped. to the crawlspace walls. Shafts,penetrations Duct shafts,utility penetrations,and flue shaft openings to exterior or unconditioned space shall ❑ be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that ❑ on installation readily conforms to the available cavity spaces. Garage Air sealinj shall be provided between the garage ❑ separation and conditioned spaces. Recessed Recessed light fixtures installed in the building Recessed light fixtures installed in the lighting thermal envelope shall be sealed to the drywall. building thermal envelope shall be air tight ❑ and IC rated. Plumbing and Batt insulation shall be cut neatly to fit around wiring wiring and plumbing in exterior walls,or insulation that on installation readily conforms ❑ to available space shall extend behind piping and wiring. Shower/tub on The air barrier shall be installed behind Exterior walls adjacent to showers and tubs exterior wall electrical or communication boxes or air-sealed shall be insulated. ❑ boxes shall be installed. Electrical/phone The air barrier shall be installed behind box on exterior electrical or communication boxes or air-sealed ❑ walls boxes shall be installed. HVAC register HVAC register boots that penetrate building boots thermal envelope shall be sealed to the subfloor ❑ or drywall. Concealed When required to be sealed,concealed fire sprinklers sprinklers shall only be sealed in a manner that is recommended by the manufacturer. ❑ Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 2018-Oct-31 05:34:17 wrj.jhtsoft`° Comfort Builder by Wrightsoft 18.0.31 RSU12270 Right-Energyw Florida 2017 Section 405.4.1 Compliant Software Page 13 , , ...ktop\Cumberland Bonus 2796 Right Lot 159 AB.rup Calc=MJ8 Front Door faces: S FORM R405-2017 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: 261300 Permit Number: Job Information Builder: Toll Brothers Community: Atlantic Beach Country Club Lot: Lot 159 ABCC Address: Lot 159 Atlantic Bea Unit: City: Atlantic Beach State: FL Zip: 32233 Air Leakage Test Results Passing results must meet either the Performance,Prescriptive,or ERI Method. PRESCRIPTIVE METHOD The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour at a pressure of 0.2 inch w.g.(50 pascals)in Climate Zones 1 and 2. The building or dwelling unit shall be tested and verified as having an air leakage rate of not PERFORMANCE or ERI METHOD exceeding the selected ACH(50)value,as shown on FORM R405-2017(Performance)or R406-2017(ERI),section labeled as Infiltration,sub-section ACH50. ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ERI): 7.000 x60- 28408 = Method for calculating building volume: CFM(50) Building Volume ACH(50) ❑ Retrieved from architectural plans PASS0 Code software calculated ❑ Field measured and calculated When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues,or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or and approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. • Testing Company Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 2018-Oct-31 05:34:17 vvrightsoft, Comfort Builder by Wrightsofl 18.0.31 RSU12270 Right-Energy® Florida 2017 Section 405.4.1 Compliant Software Page 14 a..• ...ktop\Cumberland Bonus 2796 Right Lot 159 AB.rup Calc=MJ8 Front Door faces: S FORM R405-2017 Duct Leakage Test Report Residential Perscriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: 261300 Permit Number: Job Information Builder: Toll Brothers Community: Atlantic Beach Country Club Lot: Lot 159 ABCC Address: Lot 159 Atlantic Bea Unit: City: Atlantic Beach State: FL Zip: 32233 Duct Leakage Test Results System 1 cfm25 I I Prescriptive Method cfm25(Total) To qualify as"substantially leak free" On Total must be less System 2 cfm25 than or equal to 0.04 if air handler unit is installed. If air handler unit is not installed, Qn Total must be less than or equal to System 3 cfm25 0.03. This testing method meets the requirements in accordance with Section R403.3.3. Sum of any Is the air handler unit installed <-004 Qn) additional systems cfm25 El (- during testing? El NO (<=0.03 Qn) Total of all systems cfm25 Performance / ERI Method cfm25(Out or Total) 2796 = On To qualify using this method, Qn must be not greater than the Total of all Total Conditioned proposed duct leakage Qn specified on Form R405-2017 or systems Square Footage R406-2017. Leakage Type selected on Form Qn specified on Form R405-2017 PASSR405-2017(Energy Calc)or R406-2017 (Energy Calc)or R406-2017 PASS FAIL Default Leakage Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statues. Testing Company Company Name: Phone: I hereby verify that the above duct leakage test results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 2018-Oct-31 05:34:17 4 vvrightsof t"' Comfort Builder by Wrightsoft 18.0.31 RSU12270 Right-Energy OO Florida 2017 Section 405.4.1 Compliant Software Page 15 ., ...ktop\Cumberland Bonus 2796 Right Lot 159 AB.rup Calc=MJ8 Front Door faces: S r- - Project Summary Job: Lot 159 ABCC (Rest of House) Byte- Renee Brown/SPG McGowan's Heating & Air Conditioning, Inc. 11320 E.Phillips Parkway Dr.,Jacksonville,Fl 32256 Phone:904-278-0339 Fax:904-278-0366 Email.saldie@mcgowansac.com Web:www.mcgowansac.corn v ,t, -..� 1Yzp� Y ,,-N,-,1„.. � ` 5.,": i f •4r! .. :it.G a b ,' -,y c • 4,`•rRIDA0 `:7 nna ? ML4AM 1 z�A..�e, r# &} 1tY� eA o j�tioo7 ''�64,N RNI a ° For: Toll Brothers H Notes: Cumberland Bonus } '4 :01.x' `. . c 1 t .E ay - u,°'' i<•l ' 4' '. , -ti 1 �j $_ 8@ P 1 � � k z}ti� ,�`- ti k�1.._ y 11�, ,y�lf•s a • .4Z _ h±,• �nC tai a':r?Iris+`/a E ��f7 •I6 6 r' 1 4 it Y. .+ ^fileA,«Wr4A4 ,'N;', k ke E.°'4,.;.i}ted :'? Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 34 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 37 °F Design TD 24 °F Daily range M Relative humidity 50 % Moisture difference 60 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 35681 Btuh Structure 29803 Btuh Ducts 5090 Btuh Ducts 6583 Btuh Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 40771 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 32069 Btuh Method Blower door Latent Cooling Equipment Load Sizing Shielding/stories 3 (partial)/2 Pressure/AVF 50 Pa/3314 cfm Structure 9111 Btuh Ducts 1166 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft') 2796 2796 Equipment latent load 13298 Btuh Volume (ft3) 28408 28408 Air changes/hour 0.67 0.42 Equipment Total Load (Sen+Lat) 45367 Btuh Equiv. AVF (cfm) 317 201 Req. total capacity at 0.70 SHR 3.8 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model 25HCB648A00310 Cond 25HCB648A00310 AHRI ref 9156554 Coil FV4CNFOO5L AHRI ref 9156554 Efficiency 9 HSPF Efficiency 12.5 EER, 16 SEER Heating input Sensible cooling 32900 Btuh Heating output 46500 Btuh @ 47°F Latent cooling 14100 Btuh Temperature rise 27 °F Total cooling 47000 Btuh Actual air flow 1567 cfm Actual air flow 1567 cfm Air flow factor 0.038 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.78 Capacity balance point=30°F Backup: Input= 12 kW, Output=40771 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ wrk fatsott 2018-Oct-30 08:48:51 ComfortBuilder Wrsoft byight18.0.31 RSU12270 ' omPage 1 11_G,iti ...hers\Cumberland Bonus 2796 Right Lot 159 AB.rup Calc=MJ8 Front Door faces: S ``N • -� ' Ot'Q First Floor ' 6x10 5" master ' m.wic '•l 14x6 • 6x12 7". .1.4 10x6 I 14x14 5„ 8x4 PA 12" In 4„ 6.10 we 3"Fan Ii`► 11 12" 16 x 16 m.bath', Li • ' bath r. 12 x 12 3"Fan family room fJ 8,. 3"Fan I\ ' 6x12 ma J 7"4 O - 10 4x8 . 6x 4„ . 6„ bed 2 111 10 12 x 12 LI k lox.. 6 J 12" 18" • stairs 12 x 12 8" ow 10x6 kitchen I 0 \ Eq----E1 • bed 3 10x6 o 0' 10x10 10x10 5"[i O 0 8„ pan laundry 1 dining6 6x„10r --; 10 [112 x 12 foyer e�: Mu 12 x 12 12x6 10x6 garage 9„ 7„ 5„ study• ', Job #: Lot 159 ABCCMcGowan's Heating & Air Conditionir Scale: 1 : 103 Performed by Renee Brown/SPG for: Page 1 Toll Brothers 11320 E.Phillips Parkway Dr. Comfort Builder by Wrightsoft • Fl Jacksonville,Fl 32256 18.0.31 RSU12270 Phone:904-278-0339 Fax:904-278-0366 2018-Oct-30 08:52:12 www.mcgowansac.com saldie@mcgowansac.com ..Bonus 2796 Right Lot 159 AB.rup iL • up 18 ' 12" stairs Lip. 6x10 12x12 12 x 12 6x14 12" r� loft R 11 18E bed 4 a/ 6x12 844 t 7 II GO ill bath 3�,,� aJ wic• 4x8 3"Fan 4" Job#: Lot 159 ABCCMcGowan's Heating & Air Conditionir Scale: 1 : 103 Performed by Renee Brown/SPG for: Page 2 Toll Brothers 11320 E.Phillips Parkway Dr. Comfort Builder by Wrightsoft Ft Jacksonville,Fl 32256 18.0.31 RSU12270 Phone:904-278-0339 Fax:904-278-0366 2018-Oct-30 08:52:13 www.mcgowansac.com saldie©mcgowansac.com ...Bonus 2796 Right Lot 159 AB.rup Manual S Compliance Report Job: Lot 159ABCC tt Date: t (Rest of House) By: Renee Brown/SPG ifft McGowan's Heating & Air Conditioning, Inc. 11320 E.Phillips Parkway Dr.,Jacksonville,Fl 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie@mcgowansac.corn Web:www.mcg owansac.corn tiot dk. xa ainta �� �ar� ?,9114 +ta�y �a �1� t! r Y.s 7er. 3ac For: Toll Brothers FI �: r � �['f£•3q ,�_ �� - ,{�, � �9�� � m:� p�r'A ',�q^ �A :�,i2.5'w a-;:� �,, ]Fr �. t d L§'yam. -. S. ! ". af at� ,, .„ *kirebid$i"k,641444 .h''.,i ''. :".` .t OSAYI Design Conditions Outdoor design DB: 99.3°F Sensible gain: 32069 Btuh Entering coil DB: 75.9°F Outdoor design WB: 80.0°F Latent gain: 13298 Btuh Entering coil WB: 63.0°F Indoor design DB: 75.0°F Total gain: 45367 Btuh Indoor RH: 50% Estimated airflow: 1567 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HCB648A00310+FV4CNF005L Actual airflow: 1567 cfm Sensible capacity: 32227 Btuh 100%of load Latent capacity: 9420 Btuh 71%of load Total capacity: 41647 Btuh 92%of load SHR: 77% ".{q”' rAyV ftp t �•,. fltr`a •t 1 yi t `i t f 'Gk ' i '7„ f e flt ¢$ -' x'p+ !Aktli d s r x t c.A 'U rn��.���.�`rmh£!l?4-i'.'�tC���d�(na.. .ah�,,"�'i",�d..cR T"i .�`����11r6�4k��� � .���'!�s.!�[...�'s'�^{..!t.+'�t.�F.�'�k�:•:"h S'iiT ;�•s��, int K:.. � r.., Design Conditions Outdoor design DB: 33.5°F Heat loss: 40771 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HCB648A00310+FV4CNFO05L Actual airflow: 1567 cfm Output capacity: 46500 Btuh 114%of load Capacity balance: 30 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1567 cfm Output capacity: 11.9 kW 100%of load Temp. rise: 31 °F Meets all requirements of ACCA Manual S. W r193�tsofY 2018-Oct-30 08:48:51 Comfort Builder by Wrightsoft 18.0.31 RSU12270 Page 1 f'- p* ...hers\Cumberland Bonus 2796 Right Lot 159 AB.rup Calc=MJ8 Front Door faces: S Duct System Summary Job: Lot 159 ABCC * r�a' :t Date: J ' (Rest of House) By: Renee Brown/SPG , ,4'tt 0ftrF McGowan's Heating & Air Conditioning, Inc. 11320 E.Phillips Parkway Dr.,Jacksonville,Fl 32256 Phone:904-278-0339 Fax 904-278-0366 Email:saldie@mcgowansac.com Web:www.mcgowansac.com _'4 S ;? -'fie tin'. 4 fi ,k d '& S d 7�1 - wn`, 2`....+4k '-.1,,,:; '1,0':', }.t;. q"• a ri f:e - , r. d i >' a r.ty. sic 1 c t t 4, i .,,,',,c: For: Toll Brothers Fl Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.195/0.195 in H2O 0.195/0.195 in H2O Lowest friction rate 0.091 in/100ft 0.091 in/100ft Actual air flow 1567 cfm 1567 cfm Total effective length (TEL) 429 ft �,1.i 3^itcv'i t .,: d ,,K.',,",' io. , a`'t'` `(s5�sByff� iiia pepi�'bl/"�� ©[�i`at 'a, p , ..4Rai mss�},.�K3�'.»' AtOtk: i0:0 t4f.C�a ...A �..J.,,A!:14.I 441..A4l1+1 `41 VwM3'E.I�., �Rf F'sy 3r,.:::-.',,',144,41:-.;.`";:-...:-.7: L,. o ;..•'',.1,.. r Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln (ft) Trunk bath 2 c 158 3 7 0.120 4.0 Ox 0 VIFx 44.3 280.0 st3 bath 3 h 636 24 20 0.126 4.0 Ox 0 VIFx 55.1 255.0 st8 bed 2 h 2169 83 83 0.118 6.0 Ox 0 VIFx 49.8 280.0 st3 bed 3 h 2540 98 85 0.114 6.0 Ox 0 VIFx 58.1 285.0 st5 bed 4 h 3467 133 128 0.124 7.0 Ox 0 VIFx 59.3 255.0 st8 dining c 2337 81 101 0.092 6.0 Ox 0 VIFx 88.1 335.0 st6 family room c 3470 129 149 0.123 7.0 Ox 0 VIFx 36.1 280.0 st3 family room-A c 3470 129 149 0.099 7.0 Ox 0 VIFx 67.2 325.0 st4 foyer h 2397 92 85 0.092 5.0 Ox 0 VIFx 89.4 335.0 st6 kitchen c 2174 58 94 0.121 6.0 Ox 0 VIFx 42.0 280.0 st3 laundry c 814 13 35 0.114 5.0 Ox 0 VIFx 62.6 280.0 st5 loft c 5354 177 231 0.129 8.0 Ox 0 VIFx 47.2 255.0 st8 m.bath c 170 4 7 0.099 5.0 Ox 0 VIFx 68.1 325.0 st4 m.wic h 2876 111 60 0.098 5.0 Ox 0 VIFx 73.5 325.0 st4 master h 4241 163 131 0.101 8.0 Ox 0 VIFx 62.5 325.0 st4 stairs up h 1299 50 36 0.130 5.0 Ox 0 VIFx 45.2 255.0 st8 study h 4399 169 127 0.091 7.0 Ox 0 VIFx 94.2 335.0 st6 we h 974 37 29 0.096 4.0 Ox 0 VIFx 75.8 330.0 st4 wic h 355 14 10 0.123 4.0 Ox 0 VIFx 56.6 260.0 st8 W rightSo t' 2018-Oct-30 08:48:51 Comfort Builder by Wrightsoft 18.0.31 RSU12270 Page 1 AICA ...hers\Cumberland Bonus 2796 Right Lot 159 AB.rup Calc=MJ8 Front Door faces: S R t i '* »e a. ,Y y air z '�'$u n,k J c P�f i .:r*°A. 1 wa 'tIQ ? ; p i+ '4 y i . .r_:'•:r� 4 :SA .1,as i l:ttg ii c„i,14 14 YM44. D�NACM/ii:IP Vr4 ! ` , 6-; ,r? .. c,I'.• , 1 4 '',' Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st8 Peak AVF 398 426 0.123 542 12.0 0 x 0 ViniFlx st7 st6 Peak AVF 342 312 0.091 627 10.0 0 x 0 ViniFlx st5 st4 Peak AVF 443 376 0.096 564 12.0 0 x 0 ViniFlx st3 st3 Peak AVF 716 709 0.096 670 14.0 0 x 0 ViniFlx st2 st5 Peak AVF 453 432 0.091 830 10.0 0 x 0 VinIFlx st2 st2 Peak AVF 1567 1567 0.091 887 18.0 0 x 0 ViniFlx st1 st7 Peak AVF 398 426 0.123 542 12.0 0 x 0 ViniFlx st2 st1 Peak AVF 1567 1567 0.091 887 18.0 0 x 0 ViniFlx i x t ,., 3,;1 r' 'A ed'E i.3'°":f:,,:. 11"1 vB f n ' ..y[ 'l" yx„� .��.Y a r''t'.st;:ii ai3. ,l4 1' etifi3'lt:15,1r n •-9t4I. 1 c� Fi', .. . 0. Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox 0 1567 1567 0 0 0 0 Ox 0 VIFx 2018-Oct-30 08:48:51 wrl]h,tsoft` Comfort Builder by Wrightsoft 18.0.31 RSU12270r Page 2 AOC . ...hers\Cumberland Bonus 2796 Right Lot 159 AB.rup Calc=MJ8 Front Door faces: S