Loading...
586 Timber Bridge Lane POOL DRAWINGSGENERAL NOTES 1. FOR POOL PLAN, SIZE, DECK EXTENTS, SPECIAL DETAILS, SEE CONTRACTOR'S POOL PLAN 2. ALL POOL CONSTRUCTION SHALL COMPLY WITH LORIDA BUILDING CODE BUILDING 2017 AND FLORIDA BUILDING CODE RESIDENTIAL 2017 TOGETHER WI -H LATEST REVISIONS AND ANSUNSPI NATIONAL STANDARD -5 FOR RESIDENTIAL INGROUND SWIMMING POOLS AND ANSIINSPI NATIONAL STANDARD -3 FOR PERMANENTLY INSTALLED RESIDENTIAL SPAS AND THE NATIONAL ELECTRIC CODE - LATEST. 3. ALL POOL PIPING TO BE SCHEDULE 40 OR 80 PVC 13EARING NSF APPROVAL UNLESS OTHERWISE NOTED. 4. THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENTS OR REQUIRED SETBACK AREAS. POOL CONTRACTOR AND/OR OWNER SHALL VERIFY LAYOUT AND ALL DIMENSIONS SHOWN PRIOR TO CONSTRUCTION. 5. CONTRACTOR SHALL DETERMINE LOCATION OF AL UTILITIES IN RELATION TO POOL AND ITS EQUIPMENT AND ENSURE MINIMUM CLEARANCE IN ACCORDANCE WITH LOCAL REGULATIONS AND ORDINANCES. 6. CONTRACTOR SHALL PROVIDE ADEQUATE TEMPORARY FENCING AROUND CONSTRUCTION AREA TO PREVENT UNAUTHORIZED ENTRY INTO POOL AR 7. IF A MANUAL FILL WATER SUPPLY IS PROVIDED,IAMINIMUM 3" ATMOSPHERIC BREAK WILL BE PROVIDED. IF AN AUTOFILL ASSEMBLY IS INSTALLED, A BACKFLOW PREVENTER WILL BE REQUIRED ON THE POTABLE WATER LINE USED TO SUPPLY THE POOL. 8. ALL STRUCTURAL, FILTRATION, AND ELECTRICAL )ETAILS OUTLINED IN THESE DRAWINGS ALSO RELATE TO SPA CONSTRUCTION. 9. ALL POOL AND SPA HEATERS SHALL BE INSTALLE) IN ACCORDANCE WITH FBC 454.2.14, "WATER HEATING EQUIPMENT." 10. TO EMPTY THE POOL FOR ANY REASON, THE HYD :ROSTATIC UPLIFT PRESSURE MUST BE ELIMINATED. THE OWNER MUST CONSULT A CONTRACTOR EXPERIENCED IN ELIMINATING UPLIFT PRESSURE. CONTRACTOR SHOULD CONSIDER INSTALLATION OF GRAVEL BED WITH UNDERDRAIN PUMPING SYSTEM IN AREAS WHERE GROUNDWATER COULD RESULT IN UPLIFT PRESSURES THAT COULD FLOAT POOL OUT OF THE GROUND.. 11, THE RESIDENTIAL SWIMMING POOL BARRIER ANWOR ITS COMPLIANT SAFETY COMPONENTS SHALL BE IN PLACE PRIOR TO FILLING OF THE POOL. FRC R4101.17 12. CODE VIOLATIONS FOUND DURING INSPECTION ARE REQUIRED TO BE CORRECTED. PLAN/PERMIT ISSUANCE DOES NOT GRANT APPROVAL OF A CODE VIOLATI )N. 2017 FRC 109.1 13. A HYDROSTATIC RELIEF VALVE SHALL BE INSTALLED IN POOLS LOCATED IN AREAS WHERE THE GROUND WATER TABLE OR POTENTIAL PERCHED WATER INTERSECTS THE POOL DURING ANY PERIOD OF ANY GIVEN YEAR. i STRUCTURAL NOTES 1. ALL REINFORCING STEEL TO CONFORM TO ASTM 615 GRADE 40. REINFORCING SHALL BE #3 BARS AT 10" ON CENTER EACH WAY WITH 15" LAP JOINT IN WALLS AND FLOORS UP TO 6 FEET DEPTH. BETWEEN 6'0" AND 10'0", USE #3 BARS AT 5" ON CENTER VERTICALLY STARITING AT 3'0" DEPTH IN THE AREA OF THE POOL OVER 6' IN TOTAL DEPTH. (ALTERNATE: #4 BARS AT 12" ON RENTER EACH WAY WITH 20" LAP JOINT IN WALLS AND FLOORS UP TO 6 FEET IN DEPTH; BETWEEN 6'0" AND 10'", JSE #4 BARS AT 6" ON CENTER VERTICALLY STARTING AT 3'0" 0 DEPTH IN THE AREA OF THE POOL OVER 6'0" IN T ITAL DEPTH). NOTE APPLIES TO NORMAL, NON -EXPANSIVE SOILS ONLY. NORMAL SOILS ARE ASSUMED TOP SSESS EQUIVALENT FLUID PRESSURE OF 35 PCF AND UNIT WEIGHT OF 120 PCF. IF CONCRETE IS CAST AGAI!IJST BARE EARTH WITHOUT SEPARATION BARRIER, MINIMUM COVER SHALL BE 3"; WITH A BARRIER (STEELTEX) BETWEEN CONCRETE AND EARTH, MINIMUM COVER SHALL BE 2". 2. POOL WALLS SHALL BE MIN. 6" THICK AND FLOOR 3 SHALL BE MIN. 6" THICK AND SHALL BE PNEUMATICALLY APPLIED CONCRETE WITH A COMPRESSIVE STRENGTH OF 4,000 PSI IN 28 DAYS. CONCRETE DECK SHALL BE 2,500 PSI. CONCRETE CONSTRUCTION WILL CONFORM TO ACI STANDARD 318, MINIMUM WALL THICKNESS MUST BE INCREASED FOR DEPTHS GREATER THAN 8'0". NOTE APPLIES TO "NORMAL" SOILS ONLY. 3. POOL OR PATIO SHALL BEAR ONLY ON ROCK OR :LEAN SAND, WHICH SHALL BE COMPACTED TO PROVIDE A STRUCTURALLY SAFE BEARING CAPACITY. ANY NSUITABLE MATERIAL ENCOUNTERED IN EXCAVATION SHALL BE REMOVED IN ITS ENTIRETY AND THE AREA SH��LL BE BACKFILLED WITH ACCEPTABLE MATERIAL AND PROPERLY COMPACTED. WHERE UNSUITABLE MATERIAL CANNOT BE REMOVED, THE POOL MUST BE REDESIGNED. 4. SOILS SHALL HAVE MINIMUM BEARING VALUE OF�000 PSF. 5. THE CONTRACTOR MUST PROTECT EXISTING STRUCTURES FROM FAILURE BY ACCEPTABLE METHODS. THE DESIGN ENGINEER ACCEPTS NO RESPONSIBILITY FOR THE SAFETY OF EXISTING STRUCTURES. CONTRACTOR Y SHOULD CONSULT WITH A STRUCTURAL ENGINE R IF EXISITING STRUCTURES HAVE THE POTENTIAL TO INFLUENCE FORCES ON THE POOL WALL, OR VICE VERSA. 6. SHOTCRETE/GUNITE (WET OR DRY) SHALL BE PROPORTIONED AND PLACED ACCORDING TO UBC SECTION 1922 AND ACI 506. CEMENT TO AGGREGATE, IN DRY WEIGHT SHALL NOT BE LESS THAN FIVE TO ONE. 7. SHOTCRETE/GUNITE SHALL NOT BE APPLIED IF;4BIENT AIR TEMPERATURE IS LESS THAN 40F AND FALLING, OR IF TEMPERATURE IS GREATER THAN 100F. NEVE : APPLY SHOTCRETE/GUNITE IN HEAVY RAIN. 8. SUBSTRATE SHOULD BE FOG -SPRAYED WITH WA -ER PRIOR TO SHOTCRETE/GUNITE APPLICATION TO ALLOW HYDRATION AND LIMIT RAPID DRYING OF CONCRETE, AND TO COOL REINFORCEMENT STEEL. 9. IF FLOOR IS TO BE POURED AND WALLS CONSTRICTED WITH SHOTCRETE/GUNITE, THE FLOOR SHALL BE POURED PRIOR TO CONSTRUCTION OF THE WALLS. FOR SHOTCRETEIGUNITE FLOORS, APPLICATION SHOULD COMMENCE IN CORNERS AND WORK TOWARDS THE CENTER OF THE POOL FOLLOWING WALL CONSTRUCTION. 10. IF EXPANSIVE SOILS (CLAYS) ARE ENCOUNTERED, THE SIDES AND BOTTOM OF THE POOL EXCAVATION MUST BE IN MOIST CONDITION IMMEDIATELY PRIOR TO PLACEMENT OF SHOTCRETE/GUNITE. 11. REINFORCEMENT STEEL SHALL MEET ASTM A615-40. LAP SPLICES SHALL BE AT LEAST 40 BAR DIAMETERS. ALL BENDS MUST BE SHARP. UBC SECTIONS 1907, 19112, AND 1924 SHALL BE USED AS A GUIDELINE. 12. LAP SPLICES SHALL BE STACKED INLINE WITH SHOTCRETE/GUNITE SPRAY DIRECTION, NOT SIDE-BY-SIDE PERPENDICULAR TO SPRAY. 13. REBAR PLACEMENT SHOULD BE SUCH THAT THE DISTANCE FROM THE INSIDE SHOTCRETE/GUNITE FACE TO REBAR SHOULD BE A MINIMUM OF THE TOTAL SHOTCRETE/GUNITE THICKNESS MINUS 3". 14. IN AREAS WHERE THE STEEL REINFORCEMENT IS FORCED TOGETHER DUE TO CURVATURE OF THE WALL, 1 - #4 BAR MAY BE SUBSTITUTED FOR 2 - #3 BARS IN ORDER TO MAINTAIN A MINIMUM 2.5 INCH SPACING. 15. UP TO 2" DIAMETER PIPING MAY BE PLACED IN THE LOWER OUTSIDE CORNER OF THE BOND BEAM PROVIDED A MINIMUM OF 1.5 INCH CLEARANCE IS MAINTAINED BETWEEN THE PIPES AND ANY PARALLEL REINFORCEMENT. 16. AN ENGINEER SHOULD BE CONSULTED IF UNUSU NL CONDITIONS ARE ENCOUNTERED. 17. IF A RAISED BOND BEAM EXCEEDS 2'0" AND SERV =S AS A RETAINING WALL FOR SOIL, THE RAISED PORTION SHOULD HAVE WALL DRAINAGE INSTALLED TO PREVENT BUILD-UP OF HYDROSTATIC PRESSURES. REVIEWED FOR CODE COMPLIANCE .�r� atitoa�saaXc+ s-f'1P9 A �'1C11'TEt1A! A 1 O G. G F- L- i" I v l 4 V a %w I a P-%M.O "r a a s ,., A a^a as REQUIREMENTS AND CONDITIONS LADD R1 REVIEWED BY: DATE: Dq 1 SEE STRUCTURAL NOTE 5 Z MINIMUM REINFORCEMENT #3 TYPICAL POOL T TO 8' DEEP BARS SPACED 10" O.C. E.W. TYPICAL EXTRA TRANSVERSE J REINFORCEMENT43 10' LENGTH SPACED ON 10" CENTERS BETWEEN MAIN BARS, CENTERED ON TRANSITION (MAY BE ELIMINATED IF NO TRANSITION EXISTS) 143 DIAGONAL, E:W. AT DRAIN SIMILAR TO LIGHT NICHE DETAIL - LONGITUDINAL POOL SECTION SHOTCRETE/GUNITE STEPS OR I BENCHES AS NEEDED I RADIUS QN NTS ADJUSTABLE FLOOR INLET. AFTER FULL CLOSE, BACK OPEN FINISHED POOL 1/2 TURN. (FLOOR INLETS SHALL FLOOR BE FLUSH WITH POOL FLOOR.) -I SUPPLY HEADER NOTE: CONCRETE ENCASEMENT OCCURS ONLY AT THE RETURN FITTING. POOL FLOOR INLET DETAIL N. T. S. NDISTURBED OIL (NO VOIDS) TYPICAL SWIMOUT DETAIL N.T.S. THE FOLLOWING TABLE PROVIDES MAXIMUM FLOW THROUGH SCH 40 PVC PIPE WITHOUT EXCEEDING THE MAXIMUM STANDARDS FOR VELOCITY (FT/SEC) PIPE SIZE 6 FT/S 8 FT/S 10 FT/S 1" 16 GPM 21 GPM 26 GPM 1Yz" 37 GPM 50 GPM 62 GPM 2" 62 GPM 82 GPM 103 GPM 24" 88 GPM 117 GPM 146 GPM 3" 138 GPM 181 GPM 227 GPM 4" 234 GPM 313 GPM 392 GPM 6" 534 GPM 712 GPM 900 GPM PUMP SIZE WILL VARY DEPENDING ON THE PUMP SPECIFICATION AND THE TOTAL DYNAMIC HEAD FOR THE SPECIFIC POOL NEEDS. X D_ WATER LEVEL (CENTER LINE OF SKIMMER) z_ EQUALIZER FITTING SPRING LOADED VERTICAL N W/ VGB-COMPLIANT CHECK EQUALIZER VALVE GRATE (IF INSTALLED) TO PUMP SUCTION VACUUM FITTING -SEE NOTE 3 BELOW NOTES: 1. SKIMMER SHALL BE VENTED TO ATMOSPHERE THROUGH OPENINGS IN THE LID, THROUGH AN ENGINEERED VENT PIPE, OR INCORPORATE AN EQUALIZER LINE. 2. EQUALIZER LINES, WHEN USED, SHALL BE LOCATED ON THE WALL WITH THE CENTER NO MORE THAN 18" BELOW THE MAX. OPERATING LEVEL. IT SHALL BE PROTECTED BY A VGB COMPLIANT COVER/GRATE. IF THE EQUALIZER LINE AND FITTING ARE NOT INSTALLED, THE SKIMMER PORT MUST BE PLUGGED. 3. WHEN USED, VACUUM CLEANER FITTINGS SHALL BE LOCATED IN AN ACCESSIBLE POSITION AT LEAST 6" AND NO GREATER THAN 12" BELOW THE MINIMUM OPERATIONAL WATER LEVEL AND BE FITTED WITH A SELF CLOSING, SELF LATCHING FITTING IN ACCORDANCE WITH IAPMO SPS 4. SKIMMER AND VACUUM FITTING DETAIL ESCUTCHEON PLATE ` j I ANCHOR SOCKET RUBBER BUMPER LADDER DETAIL N.T.S. CROSS BRACE RECOMMENDED WATER ' LEVEL LADDER TREADS SHALL BE SLIP -RESISTANT POOL WALL 6" MIN. FLOOR REINF. AS PER STANDARD PLAN -TO PUMP r,�a j 1 1/2" DIA. -11 HYDROSTATIC RELIEF - PIPE BOTTOM 12" PERFORATED. (SEE GENERAL NOTE 13) -- I I 314"-1-1/2" DRAIN ROCK MAIN DRAIN DETAIL N.T.S PLANS EXPIRE: NOVEMBER 6, 2018 &Mai= awlw Certificate of Authority No. 28177 a�aaw}3�l��(�Idf3T, SUITE 101 •• LSC El�/St�°. t�` f"' i 6 '4 ■ 6 • e a s • f • a A: O• • b "o- b i d p♦4♦S♦ V ,, 6J l��wcca-mtat �Fi,��tdEER 2 - #3 BARS BENT AS SHOWN EACH I I_ WAY AND LAPPED 18" WITH FLOOR _ REINFORCEMENT. II- MIN. 3" ao CLEARANCE FROM EARTH II - ..I I 24" SQ ORO PLANS VALID FOR THIS BUILDING DEPT. ONLY: A 4 Lij� �j e, ?,x�, CITY OF I FL RESIDENTIAL GENERAL NOTES AND DETAILS POOLS BY JOHN GARNER CPC 049389, 1456631, 1457486 10221 BEACH BLVD. JACKSONVILLE, FL 32246 904-743-2060 DWG. BY: MAC NOT TO SCALE SHEET 1 OF 4 APPROVED BY: JEL 0 1/2" WHITE VINYL JOINT STRIP (N/A FOR PAVER DECKS) CONCRETE DECK (OPTIONAL) WITH SLIP RESISTANT TOPPING ON COMPACTED GROUND WITH ALL ORGANIC MATERIAL REMOVED. 4" THK. WITH FIBER MESH, 6" WITH #3 REBAR 3 EA #3 REBAR CONTINUOUS 18" LAP SPLICES AS NECESSARY 3" MIN. STD. REINF: #3 REBAR @ 10" O.C. B.W. MIN. COVER 3" (EARTH SIDE), 2" (POOL SIDE). REFER TO STRUCTURAL NOTE #1 FOR ALTERNATE SCHEDULE. WATER LINE TILE, I GLAZED, MIN. 4" I TYPICAL WALL RETURN, OR VACUUM FITTING, WITH WATER STOP FLANGE LIGHT FIXTURE & NICHE R = 6" WHEN H = 3'-0" RADIUS INCREASES 6" FOR EACH 1' OF DEPTH < 5'-0" R = 2'-0" WHEN H = 5'-0" RADIUS INCREASES 1' FOR EACH 1' OF DEPTH > 6 -0 - QUARTZ AGGREGATE PLASTER FINISH SHOTCRETE/GUNITE WALL 6" MIN SHELL � TYPICAL POOL WALL SECTION SCALE: N. T. S. SPA WALL SCHEDULE 3" MIN. (TYP.) CONCRETE TH OF THICKNESS WATER FT p3 INCHES 3.0 6 3.5 6 4.0 8 4.5 10 5.0 10 VERTICAL REINFORCEMENT #3 - 10 INCH CENTERS. NOTE: GREATER WALL THICKNESS (T) OR DOUBLE CURTAIN REINFORCEMENT MAY BE USED IF REQUIRED FOR AESTHETICS OR PLUMBING SEE SPA WALL SCH. SEE STRUCTURAL 6" NOTE 15 2 - #3 BARS R 1 - #4 BAR 1- (o BAR) II i HORIZ. REIN. #3 BARS 8" • O.C. FOR FREE STANDING WALLS = TYPICAL REINF. VERT. REINF. SEE SPA I I 10" O.C. E.W. WALL SCH. z SPA DETAIL N.T.S. a ifl — FLOOR REINF. CONT. FROM SPA TO POOL — MIN. 15" LAP EITHER DIRECTION z CV 10" MIN. WATERALTERNATE TROUGH 12" PLUMBING I LOCATION AT GRADE AT GRADE P. -I it WATER I OR ELEVATED TROUGH I I I I Q II OR � II I SHEER DESCENT DETAIL N.T.S. n vl PLANS VALID FOR THIS PLANS EXPIRE: BUILDING DEPT. ONLY: NOVEMBER 612018 CITY OF c4 I I L Certificate jjMtWjjylt4 28177 4337 BL`b 0 KS C 101 �ko LE, tle ® /tr '4�` �. Fi1Xr $G�skq, sfts�!'f o. 56714 v ° • B � 9 � 9 TE OF uu fa lCj:i3P�s4gtier.s. + RESIDENTIAL STRUCTURAL DETAILS POOLS BY JOHN GARNER CPC 049389, 1456631, 1457486 10221 BEACH BLVD. JACKSONVILLE, FL 32246 904-743-2060 DWG. BY: MAC NOT TO SCALE SHEET 2 OF 4 APPROVED BY: JEL Z 3" MIN. (TYP.) a EXPANSION JOINT 8"- 11" DECK SLAB VINYL DECK SLAB 6" z in =I TILE —_III � I I cD -� I 00 ( CD SEE STRUCTURAL NOTE 15 I ALTERNATE LOCATION OF I I I q BOND BEAM REIN. 3-#3 I BOND BEAM BAR (TYP) BARS (TYP. FOR ALL BOND BEAMS) I OZ 0 CANTILEVER DECK DETAIL COPING DETAIL 3" I. C) N.T.S. MIN. z Q N.T.S. � J J I io Q 2 - 93 EACH WAY I II I EXPANSION JOINT DECK SLAB LIGHT NICHE DETAIL BEND DOWN I N. T. S. 2'- #3 t BOND BEAM BARS I =C0 #3 BAR BEND I I I AS SHOWN _ _ I 343 MINIMAL BOND BEAM SKIMMER DETAIL N.T.S. N.T.S. NOTE: MAYBE USED WITH SAND, GRAVEL, OR ROCK SOIL CONDITIONS ONLY. z CV 10" MIN. WATERALTERNATE TROUGH 12" PLUMBING I LOCATION AT GRADE AT GRADE P. -I it WATER I OR ELEVATED TROUGH I I I I Q II OR � II I SHEER DESCENT DETAIL N.T.S. n vl PLANS VALID FOR THIS PLANS EXPIRE: BUILDING DEPT. ONLY: NOVEMBER 612018 CITY OF c4 I I L Certificate jjMtWjjylt4 28177 4337 BL`b 0 KS C 101 �ko LE, tle ® /tr '4�` �. Fi1Xr $G�skq, sfts�!'f o. 56714 v ° • B � 9 � 9 TE OF uu fa lCj:i3P�s4gtier.s. + RESIDENTIAL STRUCTURAL DETAILS POOLS BY JOHN GARNER CPC 049389, 1456631, 1457486 10221 BEACH BLVD. JACKSONVILLE, FL 32246 904-743-2060 DWG. BY: MAC NOT TO SCALE SHEET 2 OF 4 APPROVED BY: JEL Z 3'0" MIN. (EDGE OF OUTLET) OUTLETS IN PARALLEL TO ONE PUMP 3'0" MIN. (EDGE OF OUTLET) UTLETS IN PARALLEL TO DUAL UMPS IN PARALLEL 3'0" MIN. (EDGE OF OUTLET) PARALLEL OUTLETS TO TWO PUMPS NOTES: 1. DUAL OUTLETS SHALL BE SEPARATED BY MINIMUM 3 FEET FROM OUTSIDE EDGE TO OUTSIDE EDGE OF OUTLET. 2. TEE ON THE SUCTION MANIFOLD SERVING THO OUTLETS SHALL BE LOCATED MIDWAY BETWEEN THE OUTLETS WITH FLOW OUT OF THE BRANCH OF THE TEE. 3. THE FLOW RATING OF EACH COVER/GRATE S ALL BE AT LEAST EQUAL TO THE SYSTEM'S MAXIMUM FLOW RATE. 4, OUTLETS MAY BE LOCATED ON SEPARATE P NES IN LIEU OF THE 3'0" SEPARATION REQUIREMENT, I.E.ONE (1) ON THE BOTTOM AND ONE (1) ON THE VERTICAL WALL, OR ONE (1) EACH ON TWO (2) SEPARATE VERTICAL WALLS. DUAL SUICTION OUTLET ARRANGEMENTS 3'0" MIN. (EDGE PF OUTLET) OUTLETS IN PARALLEL SYMMETRIC PIP(NG 3'0" MIN. (EDGE OF OUTLET) OUTLETS IN PARALLEL ECCENTRICALLY TAPPED PIPING 3'0" MIN. (EDGE OF OUTLET) OUTLETS IN PARALLEL LOOPED PIPING NOTES: 1. THE OUTERMOST OUTLETS SHALL BE SE �ARATED BY MINIMUM 3 FEET FROM OUTSIDE EDGE TO OUTSIDE EDGE OF OUTLET. 2. TEE ON THE SUCTION MANIFOLD SERVIN THE OUTLETS SHALL BE LOCATED MIDWAY BETWEEN TWO OF THE OUTLETS WITH FLOW OUT OF THE BRANCH OF THE TEE. 3. THE SUM OF THE FLOW RATINGS OF THE COVERS/GRATES SHALL BE AT LEAST TWICE THE SYSTEM'S MAXIMUM FLOW RATE. THREE -OR -MORE SUCTION OUTLET ARRANGEMENTS NOTES: 1. ALL COVERS/GRATES SHALL COMPLY WITH ANSI/ASME Al 12.19.8 -LATEST, "SUCTION FITTINGS FOR USE IN SWIMMING POOLS, WADING POOLS, SPAS AND HOT TUBS. RECOMMENDED: GRATES SHOULD BE INSTALLED WITH SUFFICIENT OPEN AREA TO ENSURE A MAXIMUM VE OCITY OF 1.5 FT/S THROUGH THE GRATE(S). 2. SUCTION OUTLETS SHALL BE INSTALLED IN ACCORDANCEIIWITH ANSI/APSP-7, LATEST. THE FOLLOWING METHODS TO AVOID ENTRAPMENT ARE IN ACCORDANCE WITH ANSI/APSP-7: A) SURFACE SKIMMING OR OVERFLOW SYSTEMS THAT PROVIDE 100% OF THE REQ UI ED SYSTEM FLOW; B) DUAL SUCTION OUTLET SYSTEMS; C) THREE -OR -MORE SUCTION OUTLET SYSTEM ; D) SINGLE UNBLOCKABLE SUCTION OUTLET SYSTEMS; E) SINGLE OUTLET SWIM JET SYSTEMS (TESTE AND LISTED AS CONFORMING TO ASME/ANSI Al 12.19.8); F) SINGLE OUTLET - ALTERNATIVE SYSTEMS (IN ACCORDANCE WITH ANSI/ASME Al 12.19.8 -LATEST AND ASTM F2387-04); G) GRAVITY FLOW TO A VENTED COL ECTOR TANK; H) OUTLET SUMPS IN SERIES; 1) OR OTHER MEANS THAT MEET THE INTENTS AND REQUIREMENTS OF ANSI/APSP-7 AND IS APPROVED BY THE AUTHORITY HAVING JURISDICTION. I 3. BRANCH SUCTION PIPING (DEFINED AS THE PIPING SERVIt� G THE SUCTION OUTLETS) SHALL BE SIZED TO ALLOW MAXIMUM VELOCITY OF SIX (6) FEET PER SECOND WHEN ONE OF A PAIR IS BLOCKED. ALL OTHER SUCTION PIPING SHALL BE SIZED TO ALLOW MAXIMUM VE IIOCITY OF EIGHT (8) FEET PER SECOND. 4_ POOLS OR SPAS SHALL NOT BE OPERATED IF SUCTION 0 TLET GRATE IS MISSING, BROKEN, OR LOOSE. 5. SUCTION INLETS SHALL BE PLUMBED SUCH THAT WATER I DRAWN THROUGH THEM SIMULTANEOUSLY THROUGH A COMMON LINE TO THE PUMP. 6. SUCTION OUTLET PORT MUST BE SAME DIAMETER OR LA IGER THAN SUCTION PIPE EXITING OUTLET. 7. FIELD BUILT SUMPS SHALL BE CONSTRUCTED SUCH THAT THE OPENING OF THE SUCTION PIPE WILL BE NO CLOSER THAN 1.5 TIMES ITS INSIDE DIAMETER FROM THE OTTOM OF THE COVER/GRATE OR SUCH THAT THE SUMP IS OF THE DESIGN SPECIFIED BY THE COVER/GRAT F MANUFACTURER TO CONTROL FLOW THROUGH THE OPEN AREA OF THE COVER/GRATE. SEE NOTE 1 BELOW CIRCULATION LINE TO LEAF CANISTER / RECIRCULATION PUMP SUCTION OUTLET SINGLE UNBLOCKABLE CHANNEL OUTLET TO SINGLE PUMP SINGLE UNBLOCKABLE CHANNEL OUTLET TO TWO PUMPS ANY SHAPE LARGE UNBLOCKABLE OUTLET OF ANY SHAPE TO SINGLE PUMP NOTES: 1. SINGLE CHANNEL OUTLET: 3" OR GREATER IN WIDTH AND 31" OR GREATER IN LENGTH (APPLIES TO PERFORATED AREA . 2. SINGLE UNBLOCKABLE OUTLET: SHALL BE OF ANY SIZE AND SHAPE SUCH THAT A REPRESENTATION OF THE TORSO OF THE 99TH PERCENTILE ADULT MALE CANNOT SUFFICIENTLY BLOCK IT TO THE EXTENT THAT IT CREATES A BODY SUCTION ENTRAPMENT HAZARD. THE TORSO IS REPRESENTED AS A RECTANGLE 18"X 23" WITH CORNERS OF RADIUS 4". SINGLE UNBLOCKABLE SUCTION OUTLET ARRANGEMENTS 12" AIR GAP (MIN.) MAXIMUM UNDERWATER LENGTH OF VENT PIPING: 30 FEET FROM TEE ON SUCTION PIPING TO AIR GAP DEBRIS OUTLET MOUNTED IN POOL FLOOR MINIMUM PIPE LENGTH 18" NOTE: 1. ONE OF THE FOLLOWING OPTIONS IS REQUIRED BETWEEN THE DEBRIS SUCTION OUTLET AND THE PUMP: A) ADDITIONAL M THE TTEE IN THE SUCCTION LINE SUCTION TOHETCOVER/GRATE PUMP(S); B) AN ENG NES ED NT O MINIMUM STEM; C) ALISTED MANUFACTURED SAFETY VACUUM RELEASE SYSTEM. OUTLET SUMPS IN SERIES TO SUCTION PIPING 2" 90° BEND (TYP. OF 2) SCREEN VENT TO PROHIBIT INSECT ENTRY OR CLOGGING. LABEL VENT AS FOLLOWS: "POOL SAFETY DEVICE - DO NOT HANDLE" VENT LINE DETAIL PLANS EXPIRE: NOVEMBER 612018 Certificate of Authority No. 28177 4337 P%.A6(ihfil�tK _RT, SUITE 101 �G E NSA'•. - . 56-71 ° 14 • e -o 16F I � � , 00 ss • `/ o Rl Sj q) SSlONAt EW*& , ;'' PLANS VALID FOR THIS BUILDING DEPT. ONLY: L4-'r-lbc -pd- I CITY OF J , FL RESIDENTIAL SUCTION OUTLET NOTES AND DETAILS POOLS BY JOHN GARNER CPC 049389, 1456631, 1457486 10221 BEACH BLVD. JACKSONVILLE, FL 32246 904-743-2060 DWG. BY: MAC NOT TO SCALE SHEET 3 OF 4 APPROVED BY: JEL IA. VELOCITY = 6 FT / S SCH 40 SCH 80 SUCTION PIPE DIAMETER MAX FLOW (GPM) MAX FLOW (GPM) 2" 63 55 21/2" 90 . 79 3" 138 124 4" 238 215 6" 540 488 3'0" MIN. (EDGE OF OUTLET) OUTLETS IN PARALLEL LOOPED PIPING NOTES: 1. THE OUTERMOST OUTLETS SHALL BE SE �ARATED BY MINIMUM 3 FEET FROM OUTSIDE EDGE TO OUTSIDE EDGE OF OUTLET. 2. TEE ON THE SUCTION MANIFOLD SERVIN THE OUTLETS SHALL BE LOCATED MIDWAY BETWEEN TWO OF THE OUTLETS WITH FLOW OUT OF THE BRANCH OF THE TEE. 3. THE SUM OF THE FLOW RATINGS OF THE COVERS/GRATES SHALL BE AT LEAST TWICE THE SYSTEM'S MAXIMUM FLOW RATE. THREE -OR -MORE SUCTION OUTLET ARRANGEMENTS NOTES: 1. ALL COVERS/GRATES SHALL COMPLY WITH ANSI/ASME Al 12.19.8 -LATEST, "SUCTION FITTINGS FOR USE IN SWIMMING POOLS, WADING POOLS, SPAS AND HOT TUBS. RECOMMENDED: GRATES SHOULD BE INSTALLED WITH SUFFICIENT OPEN AREA TO ENSURE A MAXIMUM VE OCITY OF 1.5 FT/S THROUGH THE GRATE(S). 2. SUCTION OUTLETS SHALL BE INSTALLED IN ACCORDANCEIIWITH ANSI/APSP-7, LATEST. THE FOLLOWING METHODS TO AVOID ENTRAPMENT ARE IN ACCORDANCE WITH ANSI/APSP-7: A) SURFACE SKIMMING OR OVERFLOW SYSTEMS THAT PROVIDE 100% OF THE REQ UI ED SYSTEM FLOW; B) DUAL SUCTION OUTLET SYSTEMS; C) THREE -OR -MORE SUCTION OUTLET SYSTEM ; D) SINGLE UNBLOCKABLE SUCTION OUTLET SYSTEMS; E) SINGLE OUTLET SWIM JET SYSTEMS (TESTE AND LISTED AS CONFORMING TO ASME/ANSI Al 12.19.8); F) SINGLE OUTLET - ALTERNATIVE SYSTEMS (IN ACCORDANCE WITH ANSI/ASME Al 12.19.8 -LATEST AND ASTM F2387-04); G) GRAVITY FLOW TO A VENTED COL ECTOR TANK; H) OUTLET SUMPS IN SERIES; 1) OR OTHER MEANS THAT MEET THE INTENTS AND REQUIREMENTS OF ANSI/APSP-7 AND IS APPROVED BY THE AUTHORITY HAVING JURISDICTION. I 3. BRANCH SUCTION PIPING (DEFINED AS THE PIPING SERVIt� G THE SUCTION OUTLETS) SHALL BE SIZED TO ALLOW MAXIMUM VELOCITY OF SIX (6) FEET PER SECOND WHEN ONE OF A PAIR IS BLOCKED. ALL OTHER SUCTION PIPING SHALL BE SIZED TO ALLOW MAXIMUM VE IIOCITY OF EIGHT (8) FEET PER SECOND. 4_ POOLS OR SPAS SHALL NOT BE OPERATED IF SUCTION 0 TLET GRATE IS MISSING, BROKEN, OR LOOSE. 5. SUCTION INLETS SHALL BE PLUMBED SUCH THAT WATER I DRAWN THROUGH THEM SIMULTANEOUSLY THROUGH A COMMON LINE TO THE PUMP. 6. SUCTION OUTLET PORT MUST BE SAME DIAMETER OR LA IGER THAN SUCTION PIPE EXITING OUTLET. 7. FIELD BUILT SUMPS SHALL BE CONSTRUCTED SUCH THAT THE OPENING OF THE SUCTION PIPE WILL BE NO CLOSER THAN 1.5 TIMES ITS INSIDE DIAMETER FROM THE OTTOM OF THE COVER/GRATE OR SUCH THAT THE SUMP IS OF THE DESIGN SPECIFIED BY THE COVER/GRAT F MANUFACTURER TO CONTROL FLOW THROUGH THE OPEN AREA OF THE COVER/GRATE. SEE NOTE 1 BELOW CIRCULATION LINE TO LEAF CANISTER / RECIRCULATION PUMP SUCTION OUTLET SINGLE UNBLOCKABLE CHANNEL OUTLET TO SINGLE PUMP SINGLE UNBLOCKABLE CHANNEL OUTLET TO TWO PUMPS ANY SHAPE LARGE UNBLOCKABLE OUTLET OF ANY SHAPE TO SINGLE PUMP NOTES: 1. SINGLE CHANNEL OUTLET: 3" OR GREATER IN WIDTH AND 31" OR GREATER IN LENGTH (APPLIES TO PERFORATED AREA . 2. SINGLE UNBLOCKABLE OUTLET: SHALL BE OF ANY SIZE AND SHAPE SUCH THAT A REPRESENTATION OF THE TORSO OF THE 99TH PERCENTILE ADULT MALE CANNOT SUFFICIENTLY BLOCK IT TO THE EXTENT THAT IT CREATES A BODY SUCTION ENTRAPMENT HAZARD. THE TORSO IS REPRESENTED AS A RECTANGLE 18"X 23" WITH CORNERS OF RADIUS 4". SINGLE UNBLOCKABLE SUCTION OUTLET ARRANGEMENTS 12" AIR GAP (MIN.) MAXIMUM UNDERWATER LENGTH OF VENT PIPING: 30 FEET FROM TEE ON SUCTION PIPING TO AIR GAP DEBRIS OUTLET MOUNTED IN POOL FLOOR MINIMUM PIPE LENGTH 18" NOTE: 1. ONE OF THE FOLLOWING OPTIONS IS REQUIRED BETWEEN THE DEBRIS SUCTION OUTLET AND THE PUMP: A) ADDITIONAL M THE TTEE IN THE SUCCTION LINE SUCTION TOHETCOVER/GRATE PUMP(S); B) AN ENG NES ED NT O MINIMUM STEM; C) ALISTED MANUFACTURED SAFETY VACUUM RELEASE SYSTEM. OUTLET SUMPS IN SERIES TO SUCTION PIPING 2" 90° BEND (TYP. OF 2) SCREEN VENT TO PROHIBIT INSECT ENTRY OR CLOGGING. LABEL VENT AS FOLLOWS: "POOL SAFETY DEVICE - DO NOT HANDLE" VENT LINE DETAIL PLANS EXPIRE: NOVEMBER 612018 Certificate of Authority No. 28177 4337 P%.A6(ihfil�tK _RT, SUITE 101 �G E NSA'•. - . 56-71 ° 14 • e -o 16F I � � , 00 ss • `/ o Rl Sj q) SSlONAt EW*& , ;'' PLANS VALID FOR THIS BUILDING DEPT. ONLY: L4-'r-lbc -pd- I CITY OF J , FL RESIDENTIAL SUCTION OUTLET NOTES AND DETAILS POOLS BY JOHN GARNER CPC 049389, 1456631, 1457486 10221 BEACH BLVD. JACKSONVILLE, FL 32246 904-743-2060 DWG. BY: MAC NOT TO SCALE SHEET 3 OF 4 APPROVED BY: JEL IA. TRANSFORMER REQUIRED FOR LOW -VOLTAGE INSTALLATIONS ONLY T MIN. FROM INSIDE WALL 1 BONDING CONDUCTOR. I REFER TO NOTE #7 I 1 t 1 �•� _ _ _ _ _ _ _ _ _._._._ ._._._._._. BONDING GRID. REFER TO NOTE #6 TYPICAL SWIMMING —\\ i /� 1 1 .77 I j REFER TO 300 WATT ; NOTE 4 UNDERWATER LIGHT LIGHT R T I I I 1 1 T BONDING GRID PLAN TIMECLOCK ENERGY EFFICIENCY NOTES: 1. TIME SWITCHES SHALL BE INSTALLED TO CONTROL SWIMMING POOL HEATERS AND PUMPS THAT CAN AUTOMATICALLY TURN THE HEATERS AND PUMPS OFF AND ON ACCORDING TO A PRESET SCHEDULE. EXCEPTIONS: 1.a. WHERE PUBLIC HEALTH STANDARDS REQUIRE 24-HOUR PUMP OPERATION 1.b. WHERE PUMPS ARE REQUIRED TO OPERATE SOLAR- AND WASTE -HEAT RECOVERY POOL SYSTEMS 1.c. WHERE PUMPS ARE POWERED EXCLUSIVELY FROM ONSITE RENEWABLE GENERATION 2. HEATED SWIMMING POOLS AND INGROUND PERMANENTLY INSTALLED SPAS SHALL BE EQUIPPED WITH A VAPOR -RETARDANT COVER ON OR AT THE WATER SURFACE OR A LIQUID COVER OR OTHER MEANS PROVEN TO REDUCE HEAT LOSS. EXCEPTION: OUTDOOR POOLS DERIVING OVER 70% OF THE ENERGY FOR HEATING FROM A SITE -RECOVERED ENERGY OR SOLAR ENERGY SOURCE COMPUTED OVER AN OPERATING SEASON. 3. POOL FILTRATION PUMP MOTORS SHALL MEET THE FOLLOWING REQUIREMENTS: 3.a. . POOL PUMP MOTORS SHALL NOT BE SPLIT -PHASE, SHADED POLE OR CAPACITOR START INDUCTION RUN TYPES 3.b. POOL PUMPS AND POOL PUMP MOTORS WITH A TOTAL HORSEPOWER (HP) OF GREATER THAN OR EQUAL TO 1 HP SHALL HAVE THE CAPABILITY OF OPERATING AT TWO OR MORE SPEEDS. THE LOW SPEED SHALL HAVE A ROTATION RATE OF NO MORE THAN j OF THE MOTOR'S MAXIMUM ROTATION RATE. 3.c. POOL PUMPS MOTOR CONTROLS SHALL HAVE THE CAPABILITY OF OPERATING THE POOL PUMP AT A MINIMUM OF TWO SPEEDS. THE DEFAULT CIRCULATION SPEED SHALL BE THE RESIDENTIAL FILTRATION SPEED WITH A HIGHER SPEED OVERRIDE CAPABILITY FOR A TEMPORARY PERIOD NOT TO EXCEED ONE NORMAL CYCLE OR 24 HOURS, WHICHEVER IS LESS. EXCEPTION: SOLAR POOL HEATING SYSTEMS SHALL BE PERMITTED TO RUN AT HIGHER SPEEDS DURING PERIODS OF USABLE SOLAR HEAT GAIN. 4. HYDRAULIC SYSTEMS FOR NEW POOLS MUST BE DESIGNED IN ACCORDANCE WITH APSP-15, "AMERICAN NATIONAL STANDARD FOR RESIDENTIAL SWIMMING POOL AND SPA ENERGY EFFICIENCY." TO GROUND FAULT CIRCUIT SPST TOGGL`= TOGGC � DISCONNECT PUMP INTERRUPTER THEN TO POWER Z � SOURCE WITH TRANSFORMER 4' MIN. JUNCTION BOX RIGID, IMC OR NON METALLIC CONDUIT ? BRASS OR NON METALLIC CONDUIT OR APPROVED EQUIVALENT :RVICE PANEL JUNCTION BOX 4' MIN.T co SPST TOGGL`= TOGGC � DISCONNECT PUMP 300 WATT UNDERWATER LIGHTS SHALL BE NEC. APPROVED AND SHALL FEATURE STAINLESS STEEL FORMING SHELL WITH BRASS MOUNTING RING. SHELL SHALL HAVE A 1" NPT CONDUIT WITH OPENING PACKING GLAND. LIGHT SHALL BE HOUSED IN A STAINLESS STEEL ENCAPSULATION BOLTED TO A CHROME PLATED FACE RING FOR COMPRESSING OF A 360° DOUBLE WALL SYNTHETIC GASKET. Z � POOL DECK `-12 V TR 3 #12 IN Y2" CON[ 12V/ 30OW WITH LOW WATER CUT-OFF OR 120 VAC W/ GFCI PER NEC ELECTRICA SERVICE PANEL PUMP MOTOR F3CONDUCTOR- H-N-G AL BAR T #8 BOND TO STRUCTURAL STEEL GROUND BAR \_�CONTROL PANEL TYPICAL GROU NOTES: 1. ALL ELECTRICAL SHALL CONFORM WITH ART 680 NEC - LATEST 2. BOND ALL SHEATHED CABLES, RACEWAYS, METAL PIPING AND ALL FIXED METAL PARTS NOT SEPARATED BY PERMANENT BARRIER, IF WITHIN 5 FT HORIZONTALLY FROM WATER, 12 FT VERTICALLY OF MAX WATER LEVEL. DIAGRAM INCOMING POWER SUPPLY NEUTRAL BAR TO GROUND ND BAR #8 BOND IN PVC CONDUIT POOL LIGHT FLEXIBLE CORD GROUNDING TERMINAL #8 BOND TO STRUCTURAL STEEL DING SCHEMATIC SS LIGHT FIXTURE & NICHE W/ COMPRESSION HUB & — 300W,12V LAMP OR 120 VAC W/ GFCI PER NEC #8 AWG PRESSURE GROUND CONNECTOR TO COMMON BONDING WITH REINFORCING STEEL OR PLUMBING JUNCTION BOX (IF USED) LADDER, HAND RAIL, TRANSFORMER DIVING BOARD, ETC... POOL METAL CONDUITS REINFORCING OR PIPING SYSTEM STEEL PUMP MOTOR ELECTRICAL NOTES: 1. GROUND AND BOND ALL POOLS AND RELATED EQUIPMENT IN ACCORDANCE WITH NEC ARTICLES 250 AND 680. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR TO ENSURE THAT ALL METALLIC PARTS OF THE POOL STRUCTURE, INCLUDING THE POOL SHELL AND DECK REINFORCING BARS AND ALL OTHER METAL PARTS ARE BONDED PER NEC ARTICLE 250 AND 680. BOND TOGETHER REINFORCING BARS USING STEEL TIE WIRES.. BOND ALL METAL PARTS TO POOL REINFORCING BARS USING #8 AWG COPPER WIRES. THESE METAL PARTS INCLUDE, BUT ARE NOT LIMITED TO LADDERS, RAILINGS, PIPING, CONDUIT, METAL DOOR FRAMES AND METAL PARTS WITHIN 5' OF INSIDE WALL OF POOL. CONNECTION SHALL BE EXOTHERMIC WELD, LISTED PRESSURE CONNECTORS OR CLAMPS AS APPLICABLE. GROUND STEEL COLUMNS (I.E. FOR TOWERS OR SLIDES) PER NEC ARTICLE 250 AND 680 AND NFPA 780. IF REINFORCING BARS ARE ENCAPSULATED WITH A NON CONDUCTIVE COMPOUND, CONTACT ENGINEER BEFORE PROCEEDING. 2. THIS ELECTRICAL INSTALLATION SHALL MEET ALL REQUIREMENTS OF NEC ARTICLES 250 AND 680. IN ACCORDANCE WITH THIS, UNDERGROUND WIRING SHALL NOT BE PERMITTED UNDER THE POOL OR WITHIN 5' HORIZONTALLY FROM THE INSIDE WALL OF THE POOL UNLESS THIS WIRING IS NECESSARY TO SUPPLY POOL EQUIPMENT PERMITTED BY NEC ARTICLE 680. ALL RECEPTACLES SHALL BE LOCATED AT LEAST 10' FROM THE INSIDE WALL OF POOLS_ ALL RECEPTACLES WITHIN 20' OF THE POOL SHALL HAVE GFCI PROTECTION. ADDITIONALLY, ALL UNDERWATER LIGHTING SHALL BE GFCI PROTECTED. MOUNTING HEIGHT FOR ANY LIGHT FIXTURES SUSPENDED OVER POOLS SHALL BE NOT LESS THAN 12' ABOVE MAXIMUM WATER LEVEL. 3. IF APPLICABLE, PROVIDE #12 AWG CONDUCTORS AND GROUND FOR 12V UNDERWATER LIGHTING CIRCUITS LESS THAN 8' IN LENGTH. FOR 12V CIRCUITS 8' TO 15' IN LENGTH, PROVIDE #8 AWG CONDUCTORS AND GROUND. FOR 12V CIRCUITS GREATER THAN 16, BUT LESS THAN 25' IN LENGTH, PROVIDE #6 AWG CONDUCTORS AND #6 GROUND. NO 12V CIRCUIT SHALL BE MORE THAN 25' IN LENGTH. 4. OPTIONAL: ELECTRICAL CONTRACTOR SHALL INSTALL NO FEWER THAN ONE 125 -VOLT 15 - OR 20 -AMPERE RECEPTACLE ON A GENERAL PURPOSE BRANCH CIRCUIT. RECEPTACLE SHALL BE LOCATED NOT LESS THAN 10 FT. FROM AND NOT MORE THAN 20 FT. FROM THE INSIDE WALL OF THE POOL. THE RECEPTACLE SHALL BE LOCATED NOT MORE THAN 6 FT. 6 IN. ABOVE THE FLOOR, PLATFORM, OR GRADE LEVEL SERVING THE POOL. 5. RECIRCULATION PUMP SHALL BE ELECTRICALLY INTERLOCKED WITH CHEMICAL EQUIPMENT, IF APPLICABLE. 6. AN EQUIPOTENTIAL COMMON BONDING GRID IS REQUIRED FOR ALL PAVED WALKING SURFACES WITHIN THREE FEET OF THE INSIDE WALLS OF THE POOL AND/OR SPA FOR THE ENTIRE POOL PERIMETER. THE BONDING GRID MAY BE COMPOSED OF STEEL REINFORCING RODS (REBAR), OR #8 BARE, SOLID COPPER CONDUCTORS. 6 X 6 X 10 WELDED WIRE FABRIC (MESH) IS ACCEPTABLE WHEN PROPERLY INSTALLED ON CHAIRS AND EACH SECTION IS CLAMPED WITH APPROPRIATE LISTED DEVICES AND/OR #8 SOLID COPPER JUMPERS. THE BONDING GRID MAY NOT BE INSTALLED DIRECTLY IN EARTH CONTACT OR WITHOUT PROPER COVER. THE INSTALLATION MUST BE IN ACCORDANCE WITH 680.26(C), NATIONAL ELECTRIC CODE (NEC - LATEST VERSION) AND FLORIDA BUILDING CODE (FBC - LATEST VERSION) W/ LATEST AMENDMENTS. 7. THE FOLLOWING IS AN ACCEPTABLE ALTERNATIVE TO THE BONDING GRID DEFINED IN NOTE #6, ABOVE: AN UNDERGROUND BONDING CONDUCTOR MADE OF A SINGLE #8 AWG BARE SOLID COPPER WIRE BURIED TO A MINIMUM DEPTH OF 4 INCHES TO 6 INCHES BELOW SUBGRADE AND 18 INCHES TO 24 INCHES FROM INSIDE WALL OF THE SWIMMING POOL OR SPA. THIS IS DEFINED A PERMISSIBLE ALTERNATIVE OR EQUIVALENT TO COMPLIANCE WITH S.680.26(C) OF THE NEC (2017), NFPA 20, ADOPTED BY REFERENCE WITHIN FBC. PLANS EXPIRE: POOL LIGHT DETAIL I NOVEMBER 6, 2018 POOL LIGHT HEATER CASE /_CONTROL PANEL III III 0 • TYPICAL BONDING SCHEMATIC PLANS VALID FOR THIS BUILDING DEPT. ONLY: AlLtp�-lt' �>J- CITY OFONVIL L •t RESIDENTIAL ELECTRICAL NOTES I ';6g 101o I AND DETAILS o o • • a s e F a s ° j4V 6 POOLS BY JOHN GARNER CPC 049389, 1456631, 1457486 10221 BEACH BLVD. JACKSONVILLE, FL 32246 904-743-2060 DWG. BY: MAC NOT TO SCALE SHEET 4 OF 4 APPROVED BY: JEL 0