586 Timber Bridge Lane POOL DRAWINGSGENERAL NOTES
1. FOR POOL PLAN, SIZE, DECK EXTENTS, SPECIAL DETAILS, SEE CONTRACTOR'S POOL PLAN
2. ALL POOL CONSTRUCTION SHALL COMPLY WITH LORIDA BUILDING CODE BUILDING 2017 AND FLORIDA
BUILDING CODE RESIDENTIAL 2017 TOGETHER WI -H LATEST REVISIONS AND ANSUNSPI NATIONAL
STANDARD -5 FOR RESIDENTIAL INGROUND SWIMMING POOLS AND ANSIINSPI NATIONAL STANDARD -3 FOR
PERMANENTLY INSTALLED RESIDENTIAL SPAS AND THE NATIONAL ELECTRIC CODE - LATEST.
3. ALL POOL PIPING TO BE SCHEDULE 40 OR 80 PVC 13EARING NSF APPROVAL UNLESS OTHERWISE NOTED.
4. THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENTS OR
REQUIRED SETBACK AREAS. POOL CONTRACTOR AND/OR OWNER SHALL VERIFY LAYOUT AND ALL
DIMENSIONS SHOWN PRIOR TO CONSTRUCTION.
5. CONTRACTOR SHALL DETERMINE LOCATION OF AL UTILITIES IN RELATION TO POOL AND ITS EQUIPMENT AND
ENSURE MINIMUM CLEARANCE IN ACCORDANCE WITH LOCAL REGULATIONS AND ORDINANCES.
6. CONTRACTOR SHALL PROVIDE ADEQUATE TEMPORARY FENCING AROUND CONSTRUCTION AREA TO
PREVENT UNAUTHORIZED ENTRY INTO POOL AR
7. IF A MANUAL FILL WATER SUPPLY IS PROVIDED,IAMINIMUM 3" ATMOSPHERIC BREAK WILL BE PROVIDED. IF
AN AUTOFILL ASSEMBLY IS INSTALLED, A BACKFLOW PREVENTER WILL BE REQUIRED ON THE POTABLE
WATER LINE USED TO SUPPLY THE POOL.
8. ALL STRUCTURAL, FILTRATION, AND ELECTRICAL )ETAILS OUTLINED IN THESE DRAWINGS ALSO RELATE TO
SPA CONSTRUCTION.
9. ALL POOL AND SPA HEATERS SHALL BE INSTALLE) IN ACCORDANCE WITH FBC 454.2.14, "WATER HEATING
EQUIPMENT."
10. TO EMPTY THE POOL FOR ANY REASON, THE HYD :ROSTATIC UPLIFT PRESSURE MUST BE ELIMINATED. THE
OWNER MUST CONSULT A CONTRACTOR EXPERIENCED IN ELIMINATING UPLIFT PRESSURE. CONTRACTOR
SHOULD CONSIDER INSTALLATION OF GRAVEL BED WITH UNDERDRAIN PUMPING SYSTEM IN AREAS WHERE
GROUNDWATER COULD RESULT IN UPLIFT PRESSURES THAT COULD FLOAT POOL OUT OF THE GROUND..
11, THE RESIDENTIAL SWIMMING POOL BARRIER ANWOR ITS COMPLIANT SAFETY COMPONENTS SHALL BE IN
PLACE PRIOR TO FILLING OF THE POOL. FRC R4101.17
12. CODE VIOLATIONS FOUND DURING INSPECTION ARE REQUIRED TO BE CORRECTED. PLAN/PERMIT ISSUANCE
DOES NOT GRANT APPROVAL OF A CODE VIOLATI )N. 2017 FRC 109.1
13. A HYDROSTATIC RELIEF VALVE SHALL BE INSTALLED IN POOLS LOCATED IN AREAS WHERE THE GROUND
WATER TABLE OR POTENTIAL PERCHED WATER INTERSECTS THE POOL DURING ANY PERIOD OF ANY GIVEN
YEAR. i
STRUCTURAL NOTES
1. ALL REINFORCING STEEL TO CONFORM TO ASTM 615 GRADE 40. REINFORCING SHALL BE #3 BARS AT 10" ON
CENTER EACH WAY WITH 15" LAP JOINT IN WALLS AND FLOORS UP TO 6 FEET DEPTH. BETWEEN 6'0" AND 10'0",
USE #3 BARS AT 5" ON CENTER VERTICALLY STARITING AT 3'0" DEPTH IN THE AREA OF THE POOL OVER 6' IN
TOTAL DEPTH. (ALTERNATE: #4 BARS AT 12" ON RENTER EACH WAY WITH 20" LAP JOINT IN WALLS AND FLOORS
UP TO 6 FEET IN DEPTH; BETWEEN 6'0" AND 10'", JSE #4 BARS AT 6" ON CENTER VERTICALLY STARTING AT 3'0"
0
DEPTH IN THE AREA OF THE POOL OVER 6'0" IN T ITAL DEPTH). NOTE APPLIES TO NORMAL, NON -EXPANSIVE
SOILS ONLY. NORMAL SOILS ARE ASSUMED TOP SSESS EQUIVALENT FLUID PRESSURE OF 35 PCF AND UNIT
WEIGHT OF 120 PCF. IF CONCRETE IS CAST AGAI!IJST BARE EARTH WITHOUT SEPARATION BARRIER, MINIMUM
COVER SHALL BE 3"; WITH A BARRIER (STEELTEX) BETWEEN CONCRETE AND EARTH, MINIMUM COVER SHALL BE
2".
2. POOL WALLS SHALL BE MIN. 6" THICK AND FLOOR 3 SHALL BE MIN. 6" THICK AND SHALL BE PNEUMATICALLY
APPLIED CONCRETE WITH A COMPRESSIVE STRENGTH OF 4,000 PSI IN 28 DAYS. CONCRETE DECK SHALL BE
2,500 PSI. CONCRETE CONSTRUCTION WILL CONFORM TO ACI STANDARD 318, MINIMUM WALL THICKNESS MUST
BE INCREASED FOR DEPTHS GREATER THAN 8'0". NOTE APPLIES TO "NORMAL" SOILS ONLY.
3. POOL OR PATIO SHALL BEAR ONLY ON ROCK OR :LEAN SAND, WHICH SHALL BE COMPACTED TO PROVIDE A
STRUCTURALLY SAFE BEARING CAPACITY. ANY NSUITABLE MATERIAL ENCOUNTERED IN EXCAVATION SHALL
BE REMOVED IN ITS ENTIRETY AND THE AREA SH��LL BE BACKFILLED WITH ACCEPTABLE MATERIAL AND
PROPERLY COMPACTED. WHERE UNSUITABLE MATERIAL CANNOT BE REMOVED, THE POOL MUST BE
REDESIGNED.
4. SOILS SHALL HAVE MINIMUM BEARING VALUE OF�000 PSF.
5. THE CONTRACTOR MUST PROTECT EXISTING STRUCTURES FROM FAILURE BY ACCEPTABLE METHODS. THE
DESIGN ENGINEER ACCEPTS NO RESPONSIBILITY FOR THE SAFETY OF EXISTING STRUCTURES. CONTRACTOR
Y
SHOULD CONSULT WITH A STRUCTURAL ENGINE R IF EXISITING STRUCTURES HAVE THE POTENTIAL TO
INFLUENCE FORCES ON THE POOL WALL, OR VICE VERSA.
6. SHOTCRETE/GUNITE (WET OR DRY) SHALL BE PROPORTIONED AND PLACED ACCORDING TO UBC SECTION 1922
AND ACI 506. CEMENT TO AGGREGATE, IN DRY WEIGHT SHALL NOT BE LESS THAN FIVE TO ONE.
7. SHOTCRETE/GUNITE SHALL NOT BE APPLIED IF;4BIENT AIR TEMPERATURE IS LESS THAN 40F AND FALLING, OR
IF TEMPERATURE IS GREATER THAN 100F. NEVE : APPLY SHOTCRETE/GUNITE IN HEAVY RAIN.
8. SUBSTRATE SHOULD BE FOG -SPRAYED WITH WA -ER PRIOR TO SHOTCRETE/GUNITE APPLICATION TO ALLOW
HYDRATION AND LIMIT RAPID DRYING OF CONCRETE, AND TO COOL REINFORCEMENT STEEL.
9. IF FLOOR IS TO BE POURED AND WALLS CONSTRICTED WITH SHOTCRETE/GUNITE, THE FLOOR SHALL BE
POURED PRIOR TO CONSTRUCTION OF THE WALLS. FOR SHOTCRETEIGUNITE FLOORS, APPLICATION SHOULD
COMMENCE IN CORNERS AND WORK TOWARDS THE CENTER OF THE POOL FOLLOWING WALL CONSTRUCTION.
10. IF EXPANSIVE SOILS (CLAYS) ARE ENCOUNTERED, THE SIDES AND BOTTOM OF THE POOL EXCAVATION MUST BE
IN MOIST CONDITION IMMEDIATELY PRIOR TO PLACEMENT OF SHOTCRETE/GUNITE.
11. REINFORCEMENT STEEL SHALL MEET ASTM A615-40. LAP SPLICES SHALL BE AT LEAST 40 BAR DIAMETERS. ALL
BENDS MUST BE SHARP. UBC SECTIONS 1907, 19112, AND 1924 SHALL BE USED AS A GUIDELINE.
12. LAP SPLICES SHALL BE STACKED INLINE WITH SHOTCRETE/GUNITE SPRAY DIRECTION, NOT SIDE-BY-SIDE
PERPENDICULAR TO SPRAY.
13. REBAR PLACEMENT SHOULD BE SUCH THAT THE DISTANCE FROM THE INSIDE SHOTCRETE/GUNITE FACE TO
REBAR SHOULD BE A MINIMUM OF THE TOTAL SHOTCRETE/GUNITE THICKNESS MINUS 3".
14. IN AREAS WHERE THE STEEL REINFORCEMENT IS FORCED TOGETHER DUE TO CURVATURE OF THE WALL, 1 - #4
BAR MAY BE SUBSTITUTED FOR 2 - #3 BARS IN ORDER TO MAINTAIN A MINIMUM 2.5 INCH SPACING.
15. UP TO 2" DIAMETER PIPING MAY BE PLACED IN THE LOWER OUTSIDE CORNER OF THE BOND BEAM PROVIDED A
MINIMUM OF 1.5 INCH CLEARANCE IS MAINTAINED BETWEEN THE PIPES AND ANY PARALLEL REINFORCEMENT.
16. AN ENGINEER SHOULD BE CONSULTED IF UNUSU NL CONDITIONS ARE ENCOUNTERED.
17. IF A RAISED BOND BEAM EXCEEDS 2'0" AND SERV =S AS A RETAINING WALL FOR SOIL, THE RAISED PORTION
SHOULD HAVE WALL DRAINAGE INSTALLED TO PREVENT BUILD-UP OF HYDROSTATIC PRESSURES.
REVIEWED FOR CODE COMPLIANCE
.�r� atitoa�saaXc+ s-f'1P9 A �'1C11'TEt1A! A 1
O G. G F- L- i" I v l 4 V a %w I a P-%M.O "r a a s ,., A a^a as
REQUIREMENTS AND CONDITIONS
LADD R1
REVIEWED BY: DATE: Dq 1
SEE STRUCTURAL NOTE 5 Z
MINIMUM REINFORCEMENT #3 TYPICAL POOL T TO 8' DEEP
BARS SPACED 10" O.C. E.W.
TYPICAL
EXTRA TRANSVERSE J
REINFORCEMENT43 10' LENGTH
SPACED ON 10" CENTERS
BETWEEN MAIN BARS,
CENTERED ON TRANSITION (MAY
BE ELIMINATED IF NO
TRANSITION EXISTS) 143 DIAGONAL, E:W. AT DRAIN
SIMILAR TO LIGHT NICHE DETAIL -
LONGITUDINAL POOL SECTION
SHOTCRETE/GUNITE STEPS OR I
BENCHES AS NEEDED I
RADIUS
QN
NTS
ADJUSTABLE FLOOR INLET.
AFTER FULL CLOSE, BACK OPEN
FINISHED POOL 1/2 TURN. (FLOOR INLETS SHALL
FLOOR BE FLUSH WITH POOL FLOOR.)
-I SUPPLY HEADER
NOTE:
CONCRETE ENCASEMENT OCCURS
ONLY AT THE RETURN FITTING.
POOL FLOOR INLET DETAIL
N. T. S.
NDISTURBED
OIL (NO VOIDS)
TYPICAL SWIMOUT DETAIL
N.T.S.
THE FOLLOWING TABLE PROVIDES MAXIMUM FLOW
THROUGH SCH 40 PVC PIPE WITHOUT EXCEEDING THE
MAXIMUM STANDARDS FOR VELOCITY (FT/SEC)
PIPE SIZE 6 FT/S 8 FT/S 10 FT/S
1" 16 GPM 21 GPM 26 GPM
1Yz" 37 GPM 50 GPM 62 GPM
2" 62 GPM 82 GPM 103 GPM
24" 88 GPM 117 GPM 146 GPM
3" 138 GPM 181 GPM 227 GPM
4" 234 GPM 313 GPM 392 GPM
6" 534 GPM 712 GPM 900 GPM
PUMP SIZE WILL VARY DEPENDING ON THE PUMP
SPECIFICATION AND THE TOTAL DYNAMIC HEAD FOR THE
SPECIFIC POOL NEEDS.
X D_
WATER LEVEL (CENTER
LINE OF SKIMMER)
z_
EQUALIZER FITTING
SPRING LOADED VERTICAL N W/ VGB-COMPLIANT
CHECK EQUALIZER VALVE GRATE (IF INSTALLED)
TO PUMP SUCTION
VACUUM FITTING -SEE
NOTE 3 BELOW
NOTES:
1. SKIMMER SHALL BE VENTED TO ATMOSPHERE THROUGH OPENINGS IN THE LID, THROUGH AN
ENGINEERED VENT PIPE, OR INCORPORATE AN EQUALIZER LINE.
2. EQUALIZER LINES, WHEN USED, SHALL BE LOCATED ON THE WALL WITH THE CENTER NO MORE THAN 18"
BELOW THE MAX. OPERATING LEVEL. IT SHALL BE PROTECTED BY A VGB COMPLIANT COVER/GRATE. IF
THE EQUALIZER LINE AND FITTING ARE NOT INSTALLED, THE SKIMMER PORT MUST BE PLUGGED.
3. WHEN USED, VACUUM CLEANER FITTINGS SHALL BE LOCATED IN AN ACCESSIBLE POSITION AT LEAST 6"
AND NO GREATER THAN 12" BELOW THE MINIMUM OPERATIONAL WATER LEVEL AND BE FITTED WITH A
SELF CLOSING, SELF LATCHING FITTING IN ACCORDANCE WITH IAPMO SPS 4.
SKIMMER AND VACUUM FITTING DETAIL
ESCUTCHEON PLATE ` j I
ANCHOR SOCKET
RUBBER BUMPER
LADDER DETAIL
N.T.S.
CROSS
BRACE
RECOMMENDED
WATER
' LEVEL
LADDER TREADS
SHALL BE
SLIP -RESISTANT
POOL WALL
6" MIN.
FLOOR REINF. AS PER
STANDARD PLAN
-TO PUMP r,�a
j
1 1/2" DIA. -11
HYDROSTATIC RELIEF -
PIPE BOTTOM 12"
PERFORATED. (SEE
GENERAL NOTE 13) --
I I
314"-1-1/2"
DRAIN ROCK
MAIN DRAIN DETAIL
N.T.S
PLANS EXPIRE:
NOVEMBER 6, 2018
&Mai=
awlw
Certificate of Authority No. 28177
a�aaw}3�l��(�Idf3T, SUITE 101
•• LSC El�/St�°. t�` f"'
i 6 '4
■ 6
• e
a s
• f
• a
A:
O•
• b
"o- b i d p♦4♦S♦ V ,,
6J l��wcca-mtat �Fi,��tdEER
2 - #3 BARS BENT
AS SHOWN EACH
I I_ WAY AND LAPPED
18" WITH FLOOR
_ REINFORCEMENT.
II- MIN. 3"
ao CLEARANCE
FROM EARTH
II -
..I I
24" SQ
ORO
PLANS VALID FOR THIS
BUILDING DEPT. ONLY:
A 4 Lij� �j e, ?,x�,
CITY OF I FL
RESIDENTIAL
GENERAL NOTES AND
DETAILS
POOLS BY JOHN GARNER
CPC 049389, 1456631, 1457486
10221 BEACH BLVD.
JACKSONVILLE, FL 32246
904-743-2060
DWG. BY: MAC
NOT TO SCALE SHEET 1 OF 4 APPROVED BY: JEL
0
1/2" WHITE VINYL JOINT
STRIP (N/A FOR PAVER
DECKS)
CONCRETE DECK (OPTIONAL)
WITH SLIP RESISTANT TOPPING
ON COMPACTED GROUND WITH
ALL ORGANIC MATERIAL
REMOVED. 4" THK. WITH FIBER
MESH, 6" WITH #3 REBAR
3 EA #3 REBAR CONTINUOUS 18"
LAP SPLICES AS NECESSARY
3"
MIN.
STD. REINF:
#3 REBAR @ 10" O.C. B.W. MIN.
COVER 3" (EARTH SIDE), 2"
(POOL SIDE). REFER TO
STRUCTURAL NOTE #1 FOR
ALTERNATE SCHEDULE.
WATER LINE TILE,
I GLAZED, MIN. 4"
I TYPICAL WALL RETURN, OR
VACUUM FITTING, WITH
WATER STOP FLANGE
LIGHT FIXTURE &
NICHE
R = 6" WHEN H = 3'-0"
RADIUS INCREASES 6" FOR EACH 1' OF DEPTH < 5'-0"
R = 2'-0" WHEN H = 5'-0"
RADIUS INCREASES 1' FOR EACH 1' OF DEPTH > 6 -0 -
QUARTZ AGGREGATE PLASTER FINISH
SHOTCRETE/GUNITE
WALL
6" MIN SHELL
�
TYPICAL POOL WALL SECTION
SCALE: N. T. S.
SPA WALL
SCHEDULE
3" MIN. (TYP.)
CONCRETE
TH OF
THICKNESS
WATER FT
p3
INCHES
3.0
6
3.5
6
4.0
8
4.5
10
5.0
10
VERTICAL
REINFORCEMENT #3 -
10 INCH CENTERS.
NOTE: GREATER WALL
THICKNESS (T) OR
DOUBLE CURTAIN
REINFORCEMENT MAY
BE USED IF REQUIRED
FOR AESTHETICS OR
PLUMBING
SEE SPA WALL SCH.
SEE STRUCTURAL
6" NOTE 15
2 - #3 BARS
R 1 - #4 BAR 1-
(o BAR)
II
i
HORIZ. REIN. #3 BARS 8" •
O.C. FOR FREE STANDING
WALLS = TYPICAL REINF.
VERT. REINF. SEE SPA I I 10" O.C. E.W.
WALL SCH. z
SPA DETAIL
N.T.S.
a ifl
— FLOOR REINF. CONT.
FROM SPA TO POOL
— MIN. 15" LAP EITHER
DIRECTION
z
CV
10" MIN.
WATERALTERNATE
TROUGH 12" PLUMBING
I LOCATION
AT GRADE AT GRADE
P. -I it
WATER I OR ELEVATED
TROUGH I I I I
Q II
OR
� II
I
SHEER DESCENT DETAIL
N.T.S.
n vl
PLANS VALID FOR THIS
PLANS EXPIRE: BUILDING DEPT. ONLY:
NOVEMBER 612018 CITY OF c4 I I L
Certificate jjMtWjjylt4 28177
4337 BL`b 0 KS C 101
�ko LE, tle ® /tr
'4�` �. Fi1Xr $G�skq, sfts�!'f
o. 56714
v °
• B
� 9
� 9
TE OF uu
fa lCj:i3P�s4gtier.s. +
RESIDENTIAL
STRUCTURAL DETAILS
POOLS BY JOHN GARNER
CPC 049389, 1456631, 1457486
10221 BEACH BLVD.
JACKSONVILLE, FL 32246
904-743-2060
DWG. BY: MAC
NOT TO SCALE SHEET 2 OF 4 APPROVED BY: JEL
Z
3" MIN. (TYP.)
a
EXPANSION JOINT 8"- 11"
DECK SLAB VINYL
DECK SLAB 6" z
in
=I TILE
—_III
� I I cD
-� I
00
( CD
SEE STRUCTURAL NOTE 15 I
ALTERNATE LOCATION OF I
I I
q
BOND BEAM REIN. 3-#3 I
BOND BEAM BAR (TYP)
BARS (TYP. FOR ALL
BOND BEAMS)
I
OZ
0
CANTILEVER DECK DETAIL
COPING DETAIL
3"
I.
C)
N.T.S.
MIN.
z Q
N.T.S.
� J
J
I
io Q
2 - 93 EACH WAY I
II
I
EXPANSION JOINT
DECK SLAB
LIGHT NICHE DETAIL
BEND DOWN
I
N. T. S.
2'- #3 t BOND BEAM BARS
I =C0
#3 BAR BEND I I
I
AS SHOWN _ _
I
343
MINIMAL BOND BEAM
SKIMMER DETAIL
N.T.S.
N.T.S.
NOTE: MAYBE USED WITH
SAND, GRAVEL, OR ROCK
SOIL CONDITIONS ONLY.
z
CV
10" MIN.
WATERALTERNATE
TROUGH 12" PLUMBING
I LOCATION
AT GRADE AT GRADE
P. -I it
WATER I OR ELEVATED
TROUGH I I I I
Q II
OR
� II
I
SHEER DESCENT DETAIL
N.T.S.
n vl
PLANS VALID FOR THIS
PLANS EXPIRE: BUILDING DEPT. ONLY:
NOVEMBER 612018 CITY OF c4 I I L
Certificate jjMtWjjylt4 28177
4337 BL`b 0 KS C 101
�ko LE, tle ® /tr
'4�` �. Fi1Xr $G�skq, sfts�!'f
o. 56714
v °
• B
� 9
� 9
TE OF uu
fa lCj:i3P�s4gtier.s. +
RESIDENTIAL
STRUCTURAL DETAILS
POOLS BY JOHN GARNER
CPC 049389, 1456631, 1457486
10221 BEACH BLVD.
JACKSONVILLE, FL 32246
904-743-2060
DWG. BY: MAC
NOT TO SCALE SHEET 2 OF 4 APPROVED BY: JEL
Z
3'0" MIN. (EDGE OF OUTLET)
OUTLETS IN PARALLEL TO ONE PUMP
3'0" MIN. (EDGE OF OUTLET)
UTLETS IN PARALLEL TO DUAL
UMPS IN PARALLEL
3'0" MIN. (EDGE OF OUTLET)
PARALLEL OUTLETS TO TWO PUMPS
NOTES:
1. DUAL OUTLETS SHALL BE SEPARATED BY MINIMUM 3 FEET FROM OUTSIDE EDGE TO OUTSIDE EDGE OF OUTLET.
2. TEE ON THE SUCTION MANIFOLD SERVING THO OUTLETS SHALL BE LOCATED MIDWAY BETWEEN THE OUTLETS WITH FLOW OUT OF THE BRANCH OF THE TEE.
3. THE FLOW RATING OF EACH COVER/GRATE S ALL BE AT LEAST EQUAL TO THE SYSTEM'S MAXIMUM FLOW RATE.
4, OUTLETS MAY BE LOCATED ON SEPARATE P NES IN LIEU OF THE 3'0" SEPARATION REQUIREMENT, I.E.ONE (1) ON THE BOTTOM AND ONE (1) ON THE
VERTICAL WALL, OR ONE (1) EACH ON TWO (2) SEPARATE VERTICAL WALLS.
DUAL SUICTION OUTLET ARRANGEMENTS
3'0" MIN. (EDGE PF OUTLET)
OUTLETS IN PARALLEL
SYMMETRIC PIP(NG
3'0" MIN. (EDGE OF OUTLET)
OUTLETS IN PARALLEL
ECCENTRICALLY TAPPED PIPING
3'0" MIN. (EDGE OF OUTLET)
OUTLETS IN PARALLEL
LOOPED PIPING
NOTES:
1. THE OUTERMOST OUTLETS SHALL BE SE �ARATED BY MINIMUM 3 FEET FROM OUTSIDE EDGE TO OUTSIDE EDGE OF OUTLET.
2. TEE ON THE SUCTION MANIFOLD SERVIN THE OUTLETS SHALL BE LOCATED MIDWAY BETWEEN TWO OF THE OUTLETS WITH FLOW OUT OF THE BRANCH OF THE TEE.
3. THE SUM OF THE FLOW RATINGS OF THE COVERS/GRATES SHALL BE AT LEAST TWICE THE SYSTEM'S MAXIMUM FLOW RATE.
THREE -OR -MORE SUCTION OUTLET ARRANGEMENTS
NOTES:
1. ALL COVERS/GRATES SHALL COMPLY WITH ANSI/ASME Al 12.19.8 -LATEST, "SUCTION FITTINGS FOR USE IN
SWIMMING POOLS, WADING POOLS, SPAS AND HOT TUBS. RECOMMENDED: GRATES SHOULD BE INSTALLED
WITH SUFFICIENT OPEN AREA TO ENSURE A MAXIMUM VE OCITY OF 1.5 FT/S THROUGH THE GRATE(S).
2. SUCTION OUTLETS SHALL BE INSTALLED IN ACCORDANCEIIWITH ANSI/APSP-7, LATEST. THE FOLLOWING
METHODS TO AVOID ENTRAPMENT ARE IN ACCORDANCE WITH ANSI/APSP-7: A) SURFACE SKIMMING OR
OVERFLOW SYSTEMS THAT PROVIDE 100% OF THE REQ
UI ED SYSTEM FLOW; B) DUAL SUCTION OUTLET
SYSTEMS; C) THREE -OR -MORE SUCTION OUTLET SYSTEM ; D) SINGLE UNBLOCKABLE SUCTION OUTLET
SYSTEMS; E) SINGLE OUTLET SWIM JET SYSTEMS (TESTE AND LISTED AS CONFORMING TO ASME/ANSI
Al 12.19.8); F) SINGLE OUTLET - ALTERNATIVE SYSTEMS (IN ACCORDANCE WITH ANSI/ASME Al 12.19.8 -LATEST
AND ASTM F2387-04); G) GRAVITY FLOW TO A VENTED COL ECTOR TANK; H) OUTLET SUMPS IN SERIES; 1) OR
OTHER MEANS THAT MEET THE INTENTS AND REQUIREMENTS OF ANSI/APSP-7 AND IS APPROVED BY THE
AUTHORITY HAVING JURISDICTION. I
3. BRANCH SUCTION PIPING (DEFINED AS THE PIPING SERVIt� G THE SUCTION OUTLETS) SHALL BE SIZED TO
ALLOW MAXIMUM VELOCITY OF SIX (6) FEET PER SECOND WHEN ONE OF A PAIR IS BLOCKED. ALL OTHER
SUCTION PIPING SHALL BE SIZED TO ALLOW MAXIMUM VE IIOCITY OF EIGHT (8) FEET PER SECOND.
4_ POOLS OR SPAS SHALL NOT BE OPERATED IF SUCTION 0 TLET GRATE IS MISSING, BROKEN, OR LOOSE.
5. SUCTION INLETS SHALL BE PLUMBED SUCH THAT WATER I DRAWN THROUGH THEM SIMULTANEOUSLY
THROUGH A COMMON LINE TO THE PUMP.
6. SUCTION OUTLET PORT MUST BE SAME DIAMETER OR LA IGER THAN SUCTION PIPE EXITING OUTLET.
7. FIELD BUILT SUMPS SHALL BE CONSTRUCTED SUCH THAT THE OPENING OF THE SUCTION PIPE WILL BE NO
CLOSER THAN 1.5 TIMES ITS INSIDE DIAMETER FROM THE OTTOM OF THE COVER/GRATE OR SUCH THAT THE
SUMP IS OF THE DESIGN SPECIFIED BY THE COVER/GRAT F MANUFACTURER TO CONTROL FLOW THROUGH
THE OPEN AREA OF THE COVER/GRATE.
SEE NOTE 1 BELOW
CIRCULATION LINE TO LEAF
CANISTER / RECIRCULATION
PUMP
SUCTION OUTLET
SINGLE UNBLOCKABLE CHANNEL OUTLET TO SINGLE PUMP
SINGLE UNBLOCKABLE CHANNEL OUTLET TO TWO PUMPS
ANY SHAPE
LARGE UNBLOCKABLE OUTLET OF ANY SHAPE TO SINGLE PUMP
NOTES:
1. SINGLE CHANNEL OUTLET: 3" OR GREATER IN WIDTH AND 31" OR GREATER IN LENGTH (APPLIES TO PERFORATED AREA .
2. SINGLE UNBLOCKABLE OUTLET: SHALL BE OF ANY SIZE AND SHAPE SUCH THAT A REPRESENTATION OF THE TORSO OF THE
99TH PERCENTILE ADULT MALE CANNOT SUFFICIENTLY BLOCK IT TO THE EXTENT THAT IT CREATES A BODY SUCTION
ENTRAPMENT HAZARD. THE TORSO IS REPRESENTED AS A RECTANGLE 18"X 23" WITH CORNERS OF RADIUS 4".
SINGLE UNBLOCKABLE SUCTION OUTLET ARRANGEMENTS
12" AIR GAP (MIN.)
MAXIMUM UNDERWATER
LENGTH OF VENT PIPING: 30
FEET FROM TEE ON
SUCTION PIPING TO AIR GAP
DEBRIS OUTLET MOUNTED
IN POOL FLOOR
MINIMUM PIPE LENGTH 18"
NOTE:
1. ONE OF THE FOLLOWING OPTIONS IS REQUIRED BETWEEN THE DEBRIS SUCTION OUTLET AND THE PUMP: A)
ADDITIONAL
M THE
TTEE IN THE SUCCTION LINE SUCTION
TOHETCOVER/GRATE
PUMP(S); B) AN ENG NES ED NT O MINIMUM STEM; C) ALISTED MANUFACTURED
SAFETY VACUUM RELEASE SYSTEM.
OUTLET SUMPS IN SERIES
TO SUCTION PIPING
2" 90° BEND (TYP.
OF 2)
SCREEN VENT TO PROHIBIT
INSECT ENTRY OR CLOGGING.
LABEL VENT AS FOLLOWS: "POOL
SAFETY DEVICE - DO NOT HANDLE"
VENT LINE DETAIL
PLANS EXPIRE:
NOVEMBER 612018
Certificate of Authority No. 28177
4337 P%.A6(ihfil�tK _RT, SUITE 101
�G E NSA'•. - .
56-71
°
14
• e
-o 16F
I � � , 00
ss • `/ o
Rl
Sj q) SSlONAt EW*& , ;''
PLANS VALID FOR THIS
BUILDING DEPT. ONLY:
L4-'r-lbc -pd- I
CITY OF J , FL
RESIDENTIAL
SUCTION OUTLET NOTES
AND DETAILS
POOLS BY JOHN GARNER
CPC 049389, 1456631, 1457486
10221 BEACH BLVD.
JACKSONVILLE, FL 32246
904-743-2060
DWG. BY: MAC
NOT TO SCALE SHEET 3 OF 4 APPROVED BY: JEL
IA.
VELOCITY = 6 FT / S
SCH 40 SCH 80
SUCTION PIPE
DIAMETER
MAX FLOW
(GPM)
MAX FLOW
(GPM)
2"
63
55
21/2"
90 .
79
3"
138
124
4"
238
215
6"
540
488
3'0" MIN. (EDGE OF OUTLET)
OUTLETS IN PARALLEL
LOOPED PIPING
NOTES:
1. THE OUTERMOST OUTLETS SHALL BE SE �ARATED BY MINIMUM 3 FEET FROM OUTSIDE EDGE TO OUTSIDE EDGE OF OUTLET.
2. TEE ON THE SUCTION MANIFOLD SERVIN THE OUTLETS SHALL BE LOCATED MIDWAY BETWEEN TWO OF THE OUTLETS WITH FLOW OUT OF THE BRANCH OF THE TEE.
3. THE SUM OF THE FLOW RATINGS OF THE COVERS/GRATES SHALL BE AT LEAST TWICE THE SYSTEM'S MAXIMUM FLOW RATE.
THREE -OR -MORE SUCTION OUTLET ARRANGEMENTS
NOTES:
1. ALL COVERS/GRATES SHALL COMPLY WITH ANSI/ASME Al 12.19.8 -LATEST, "SUCTION FITTINGS FOR USE IN
SWIMMING POOLS, WADING POOLS, SPAS AND HOT TUBS. RECOMMENDED: GRATES SHOULD BE INSTALLED
WITH SUFFICIENT OPEN AREA TO ENSURE A MAXIMUM VE OCITY OF 1.5 FT/S THROUGH THE GRATE(S).
2. SUCTION OUTLETS SHALL BE INSTALLED IN ACCORDANCEIIWITH ANSI/APSP-7, LATEST. THE FOLLOWING
METHODS TO AVOID ENTRAPMENT ARE IN ACCORDANCE WITH ANSI/APSP-7: A) SURFACE SKIMMING OR
OVERFLOW SYSTEMS THAT PROVIDE 100% OF THE REQ
UI ED SYSTEM FLOW; B) DUAL SUCTION OUTLET
SYSTEMS; C) THREE -OR -MORE SUCTION OUTLET SYSTEM ; D) SINGLE UNBLOCKABLE SUCTION OUTLET
SYSTEMS; E) SINGLE OUTLET SWIM JET SYSTEMS (TESTE AND LISTED AS CONFORMING TO ASME/ANSI
Al 12.19.8); F) SINGLE OUTLET - ALTERNATIVE SYSTEMS (IN ACCORDANCE WITH ANSI/ASME Al 12.19.8 -LATEST
AND ASTM F2387-04); G) GRAVITY FLOW TO A VENTED COL ECTOR TANK; H) OUTLET SUMPS IN SERIES; 1) OR
OTHER MEANS THAT MEET THE INTENTS AND REQUIREMENTS OF ANSI/APSP-7 AND IS APPROVED BY THE
AUTHORITY HAVING JURISDICTION. I
3. BRANCH SUCTION PIPING (DEFINED AS THE PIPING SERVIt� G THE SUCTION OUTLETS) SHALL BE SIZED TO
ALLOW MAXIMUM VELOCITY OF SIX (6) FEET PER SECOND WHEN ONE OF A PAIR IS BLOCKED. ALL OTHER
SUCTION PIPING SHALL BE SIZED TO ALLOW MAXIMUM VE IIOCITY OF EIGHT (8) FEET PER SECOND.
4_ POOLS OR SPAS SHALL NOT BE OPERATED IF SUCTION 0 TLET GRATE IS MISSING, BROKEN, OR LOOSE.
5. SUCTION INLETS SHALL BE PLUMBED SUCH THAT WATER I DRAWN THROUGH THEM SIMULTANEOUSLY
THROUGH A COMMON LINE TO THE PUMP.
6. SUCTION OUTLET PORT MUST BE SAME DIAMETER OR LA IGER THAN SUCTION PIPE EXITING OUTLET.
7. FIELD BUILT SUMPS SHALL BE CONSTRUCTED SUCH THAT THE OPENING OF THE SUCTION PIPE WILL BE NO
CLOSER THAN 1.5 TIMES ITS INSIDE DIAMETER FROM THE OTTOM OF THE COVER/GRATE OR SUCH THAT THE
SUMP IS OF THE DESIGN SPECIFIED BY THE COVER/GRAT F MANUFACTURER TO CONTROL FLOW THROUGH
THE OPEN AREA OF THE COVER/GRATE.
SEE NOTE 1 BELOW
CIRCULATION LINE TO LEAF
CANISTER / RECIRCULATION
PUMP
SUCTION OUTLET
SINGLE UNBLOCKABLE CHANNEL OUTLET TO SINGLE PUMP
SINGLE UNBLOCKABLE CHANNEL OUTLET TO TWO PUMPS
ANY SHAPE
LARGE UNBLOCKABLE OUTLET OF ANY SHAPE TO SINGLE PUMP
NOTES:
1. SINGLE CHANNEL OUTLET: 3" OR GREATER IN WIDTH AND 31" OR GREATER IN LENGTH (APPLIES TO PERFORATED AREA .
2. SINGLE UNBLOCKABLE OUTLET: SHALL BE OF ANY SIZE AND SHAPE SUCH THAT A REPRESENTATION OF THE TORSO OF THE
99TH PERCENTILE ADULT MALE CANNOT SUFFICIENTLY BLOCK IT TO THE EXTENT THAT IT CREATES A BODY SUCTION
ENTRAPMENT HAZARD. THE TORSO IS REPRESENTED AS A RECTANGLE 18"X 23" WITH CORNERS OF RADIUS 4".
SINGLE UNBLOCKABLE SUCTION OUTLET ARRANGEMENTS
12" AIR GAP (MIN.)
MAXIMUM UNDERWATER
LENGTH OF VENT PIPING: 30
FEET FROM TEE ON
SUCTION PIPING TO AIR GAP
DEBRIS OUTLET MOUNTED
IN POOL FLOOR
MINIMUM PIPE LENGTH 18"
NOTE:
1. ONE OF THE FOLLOWING OPTIONS IS REQUIRED BETWEEN THE DEBRIS SUCTION OUTLET AND THE PUMP: A)
ADDITIONAL
M THE
TTEE IN THE SUCCTION LINE SUCTION
TOHETCOVER/GRATE
PUMP(S); B) AN ENG NES ED NT O MINIMUM STEM; C) ALISTED MANUFACTURED
SAFETY VACUUM RELEASE SYSTEM.
OUTLET SUMPS IN SERIES
TO SUCTION PIPING
2" 90° BEND (TYP.
OF 2)
SCREEN VENT TO PROHIBIT
INSECT ENTRY OR CLOGGING.
LABEL VENT AS FOLLOWS: "POOL
SAFETY DEVICE - DO NOT HANDLE"
VENT LINE DETAIL
PLANS EXPIRE:
NOVEMBER 612018
Certificate of Authority No. 28177
4337 P%.A6(ihfil�tK _RT, SUITE 101
�G E NSA'•. - .
56-71
°
14
• e
-o 16F
I � � , 00
ss • `/ o
Rl
Sj q) SSlONAt EW*& , ;''
PLANS VALID FOR THIS
BUILDING DEPT. ONLY:
L4-'r-lbc -pd- I
CITY OF J , FL
RESIDENTIAL
SUCTION OUTLET NOTES
AND DETAILS
POOLS BY JOHN GARNER
CPC 049389, 1456631, 1457486
10221 BEACH BLVD.
JACKSONVILLE, FL 32246
904-743-2060
DWG. BY: MAC
NOT TO SCALE SHEET 3 OF 4 APPROVED BY: JEL
IA.
TRANSFORMER REQUIRED FOR
LOW -VOLTAGE INSTALLATIONS ONLY
T MIN. FROM INSIDE WALL
1
BONDING CONDUCTOR.
I REFER TO NOTE #7
I
1
t
1
�•� _ _ _ _ _ _ _ _ _._._._ ._._._._._.
BONDING GRID.
REFER TO NOTE #6
TYPICAL SWIMMING
—\\
i /�
1
1
.77
I
j REFER TO
300 WATT ; NOTE 4
UNDERWATER
LIGHT LIGHT
R
T
I
I
I
1
1
T
BONDING GRID PLAN
TIMECLOCK
ENERGY EFFICIENCY NOTES:
1. TIME SWITCHES SHALL BE INSTALLED TO CONTROL SWIMMING POOL HEATERS AND
PUMPS THAT CAN AUTOMATICALLY TURN THE HEATERS AND PUMPS OFF AND ON
ACCORDING TO A PRESET SCHEDULE. EXCEPTIONS:
1.a. WHERE PUBLIC HEALTH STANDARDS REQUIRE 24-HOUR PUMP OPERATION
1.b. WHERE PUMPS ARE REQUIRED TO OPERATE SOLAR- AND WASTE -HEAT RECOVERY
POOL SYSTEMS
1.c. WHERE PUMPS ARE POWERED EXCLUSIVELY FROM ONSITE RENEWABLE
GENERATION
2. HEATED SWIMMING POOLS AND INGROUND PERMANENTLY INSTALLED SPAS SHALL BE
EQUIPPED WITH A VAPOR -RETARDANT COVER ON OR AT THE WATER SURFACE OR A
LIQUID COVER OR OTHER MEANS PROVEN TO REDUCE HEAT LOSS. EXCEPTION:
OUTDOOR POOLS DERIVING OVER 70% OF THE ENERGY FOR HEATING FROM A
SITE -RECOVERED ENERGY OR SOLAR ENERGY SOURCE COMPUTED OVER AN
OPERATING SEASON.
3. POOL FILTRATION PUMP MOTORS SHALL MEET THE FOLLOWING REQUIREMENTS:
3.a. . POOL PUMP MOTORS SHALL NOT BE SPLIT -PHASE, SHADED POLE OR CAPACITOR
START INDUCTION RUN TYPES
3.b. POOL PUMPS AND POOL PUMP MOTORS WITH A TOTAL HORSEPOWER (HP) OF
GREATER THAN OR EQUAL TO 1 HP SHALL HAVE THE CAPABILITY OF OPERATING AT
TWO OR MORE SPEEDS. THE LOW SPEED SHALL HAVE A ROTATION RATE OF NO
MORE THAN j OF THE MOTOR'S MAXIMUM ROTATION RATE.
3.c. POOL PUMPS MOTOR CONTROLS SHALL HAVE THE CAPABILITY OF OPERATING THE
POOL PUMP AT A MINIMUM OF TWO SPEEDS. THE DEFAULT CIRCULATION SPEED
SHALL BE THE RESIDENTIAL FILTRATION SPEED WITH A HIGHER SPEED OVERRIDE
CAPABILITY FOR A TEMPORARY PERIOD NOT TO EXCEED ONE NORMAL CYCLE OR
24 HOURS, WHICHEVER IS LESS. EXCEPTION: SOLAR POOL HEATING SYSTEMS
SHALL BE PERMITTED TO RUN AT HIGHER SPEEDS DURING PERIODS OF USABLE
SOLAR HEAT GAIN.
4. HYDRAULIC SYSTEMS FOR NEW POOLS MUST BE DESIGNED IN ACCORDANCE WITH
APSP-15, "AMERICAN NATIONAL STANDARD FOR RESIDENTIAL SWIMMING POOL AND
SPA ENERGY EFFICIENCY."
TO GROUND FAULT CIRCUIT
SPST
TOGGL`=
TOGGC �
DISCONNECT
PUMP
INTERRUPTER THEN TO POWER
Z
�
SOURCE WITH TRANSFORMER
4' MIN.
JUNCTION BOX
RIGID, IMC OR NON METALLIC
CONDUIT
?
BRASS OR NON METALLIC
CONDUIT OR APPROVED
EQUIVALENT
:RVICE PANEL
JUNCTION
BOX
4' MIN.T
co
SPST
TOGGL`=
TOGGC �
DISCONNECT
PUMP
300 WATT UNDERWATER LIGHTS SHALL BE NEC.
APPROVED AND SHALL FEATURE STAINLESS STEEL
FORMING SHELL WITH BRASS MOUNTING RING.
SHELL SHALL HAVE A 1" NPT CONDUIT WITH OPENING
PACKING GLAND. LIGHT SHALL BE HOUSED IN A
STAINLESS STEEL ENCAPSULATION BOLTED TO A
CHROME PLATED FACE RING FOR COMPRESSING OF
A 360° DOUBLE WALL SYNTHETIC GASKET.
Z
�
POOL DECK `-12 V TR
3 #12 IN Y2" CON[
12V/ 30OW WITH LOW WATER
CUT-OFF OR 120 VAC W/ GFCI
PER NEC
ELECTRICA
SERVICE PANEL
PUMP
MOTOR
F3CONDUCTOR-
H-N-G
AL BAR T
#8 BOND TO
STRUCTURAL STEEL GROUND BAR
\_�CONTROL PANEL
TYPICAL GROU
NOTES:
1. ALL ELECTRICAL SHALL CONFORM WITH ART 680 NEC -
LATEST
2. BOND ALL SHEATHED CABLES, RACEWAYS, METAL PIPING
AND ALL FIXED METAL PARTS NOT SEPARATED BY
PERMANENT BARRIER, IF WITHIN 5 FT HORIZONTALLY FROM
WATER, 12 FT VERTICALLY OF MAX WATER LEVEL.
DIAGRAM
INCOMING POWER SUPPLY
NEUTRAL BAR
TO GROUND
ND BAR
#8 BOND IN
PVC CONDUIT
POOL LIGHT
FLEXIBLE CORD
GROUNDING TERMINAL
#8 BOND TO
STRUCTURAL
STEEL
DING SCHEMATIC
SS LIGHT FIXTURE & NICHE W/ COMPRESSION HUB & —
300W,12V LAMP OR 120 VAC W/ GFCI PER NEC
#8 AWG PRESSURE GROUND
CONNECTOR TO COMMON
BONDING WITH REINFORCING
STEEL OR PLUMBING
JUNCTION BOX (IF USED)
LADDER, HAND RAIL, TRANSFORMER
DIVING BOARD, ETC...
POOL
METAL CONDUITS REINFORCING
OR PIPING SYSTEM STEEL
PUMP MOTOR
ELECTRICAL NOTES:
1. GROUND AND BOND ALL POOLS AND RELATED EQUIPMENT IN ACCORDANCE WITH NEC
ARTICLES 250 AND 680. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH GENERAL
CONTRACTOR TO ENSURE THAT ALL METALLIC PARTS OF THE POOL STRUCTURE,
INCLUDING THE POOL SHELL AND DECK REINFORCING BARS AND ALL OTHER METAL
PARTS ARE BONDED PER NEC ARTICLE 250 AND 680. BOND TOGETHER REINFORCING
BARS USING STEEL TIE WIRES.. BOND ALL METAL PARTS TO POOL REINFORCING BARS
USING #8 AWG COPPER WIRES. THESE METAL PARTS INCLUDE, BUT ARE NOT LIMITED
TO LADDERS, RAILINGS, PIPING, CONDUIT, METAL DOOR FRAMES AND METAL PARTS
WITHIN 5' OF INSIDE WALL OF POOL. CONNECTION SHALL BE EXOTHERMIC WELD, LISTED
PRESSURE CONNECTORS OR CLAMPS AS APPLICABLE. GROUND STEEL COLUMNS (I.E.
FOR TOWERS OR SLIDES) PER NEC ARTICLE 250 AND 680 AND NFPA 780. IF REINFORCING
BARS ARE ENCAPSULATED WITH A NON CONDUCTIVE COMPOUND, CONTACT ENGINEER
BEFORE PROCEEDING.
2. THIS ELECTRICAL INSTALLATION SHALL MEET ALL REQUIREMENTS OF NEC ARTICLES 250
AND 680. IN ACCORDANCE WITH THIS, UNDERGROUND WIRING SHALL NOT BE PERMITTED
UNDER THE POOL OR WITHIN 5' HORIZONTALLY FROM THE INSIDE WALL OF THE POOL
UNLESS THIS WIRING IS NECESSARY TO SUPPLY POOL EQUIPMENT PERMITTED BY NEC
ARTICLE 680. ALL RECEPTACLES SHALL BE LOCATED AT LEAST 10' FROM THE INSIDE
WALL OF POOLS_ ALL RECEPTACLES WITHIN 20' OF THE POOL SHALL HAVE GFCI
PROTECTION. ADDITIONALLY, ALL UNDERWATER LIGHTING SHALL BE GFCI PROTECTED.
MOUNTING HEIGHT FOR ANY LIGHT FIXTURES SUSPENDED OVER POOLS SHALL BE NOT
LESS THAN 12' ABOVE MAXIMUM WATER LEVEL.
3. IF APPLICABLE, PROVIDE #12 AWG CONDUCTORS AND GROUND FOR 12V UNDERWATER
LIGHTING CIRCUITS LESS THAN 8' IN LENGTH. FOR 12V CIRCUITS 8' TO 15' IN LENGTH,
PROVIDE #8 AWG CONDUCTORS AND GROUND. FOR 12V CIRCUITS GREATER THAN 16,
BUT LESS THAN 25' IN LENGTH, PROVIDE #6 AWG CONDUCTORS AND #6 GROUND. NO 12V
CIRCUIT SHALL BE MORE THAN 25' IN LENGTH.
4. OPTIONAL: ELECTRICAL CONTRACTOR SHALL INSTALL NO FEWER THAN ONE 125 -VOLT 15 -
OR 20 -AMPERE RECEPTACLE ON A GENERAL PURPOSE BRANCH CIRCUIT. RECEPTACLE
SHALL BE LOCATED NOT LESS THAN 10 FT. FROM AND NOT MORE THAN 20 FT. FROM THE
INSIDE WALL OF THE POOL. THE RECEPTACLE SHALL BE LOCATED NOT MORE THAN 6 FT.
6 IN. ABOVE THE FLOOR, PLATFORM, OR GRADE LEVEL SERVING THE POOL.
5. RECIRCULATION PUMP SHALL BE ELECTRICALLY INTERLOCKED WITH CHEMICAL
EQUIPMENT, IF APPLICABLE.
6. AN EQUIPOTENTIAL COMMON BONDING GRID IS REQUIRED FOR ALL PAVED WALKING
SURFACES WITHIN THREE FEET OF THE INSIDE WALLS OF THE POOL AND/OR SPA FOR
THE ENTIRE POOL PERIMETER. THE BONDING GRID MAY BE COMPOSED OF STEEL
REINFORCING RODS (REBAR), OR #8 BARE, SOLID COPPER CONDUCTORS. 6 X 6 X 10
WELDED WIRE FABRIC (MESH) IS ACCEPTABLE WHEN PROPERLY INSTALLED ON CHAIRS
AND EACH SECTION IS CLAMPED WITH APPROPRIATE LISTED DEVICES AND/OR #8 SOLID
COPPER JUMPERS. THE BONDING GRID MAY NOT BE INSTALLED DIRECTLY IN EARTH
CONTACT OR WITHOUT PROPER COVER. THE INSTALLATION MUST BE IN ACCORDANCE
WITH 680.26(C), NATIONAL ELECTRIC CODE (NEC - LATEST VERSION) AND FLORIDA
BUILDING CODE (FBC - LATEST VERSION) W/ LATEST AMENDMENTS.
7. THE FOLLOWING IS AN ACCEPTABLE ALTERNATIVE TO THE BONDING GRID DEFINED IN
NOTE #6, ABOVE: AN UNDERGROUND BONDING CONDUCTOR MADE OF A SINGLE #8 AWG
BARE SOLID COPPER WIRE BURIED TO A MINIMUM DEPTH OF 4 INCHES TO 6 INCHES
BELOW SUBGRADE AND 18 INCHES TO 24 INCHES FROM INSIDE WALL OF THE SWIMMING
POOL OR SPA. THIS IS DEFINED A PERMISSIBLE ALTERNATIVE OR EQUIVALENT TO
COMPLIANCE WITH S.680.26(C) OF THE NEC (2017), NFPA 20, ADOPTED BY REFERENCE
WITHIN FBC.
PLANS EXPIRE:
POOL LIGHT DETAIL I NOVEMBER 6, 2018
POOL LIGHT
HEATER CASE
/_CONTROL
PANEL
III III
0
•
TYPICAL BONDING SCHEMATIC
PLANS VALID FOR THIS
BUILDING DEPT. ONLY:
AlLtp�-lt' �>J-
CITY OFONVIL L
•t RESIDENTIAL
ELECTRICAL NOTES
I ';6g 101o I AND DETAILS
o
o
•
• a
s e
F a
s °
j4V 6
POOLS BY JOHN GARNER
CPC 049389, 1456631, 1457486
10221 BEACH BLVD.
JACKSONVILLE, FL 32246
904-743-2060
DWG. BY: MAC
NOT TO SCALE SHEET 4 OF 4 APPROVED BY: JEL