Loading...
1221 MAYPORT RD ELPP18-002816" ANGLE BRACE FRAMES (BY OTHERS) MAX SPACING OF @ 48" OC (MIN OF 3 BRACES FOR THIS SIGN) ATTACHED TO ROOF PER TABLE BELOW 60' 131 SIGN FACE, CABINET & RACEWAY ATTACHED TO EACH BRACE w/ (2) 318" THRU BOLTS (DESIGNED BY OTHERS) FASTENER THRU ANGLE FRAME -0 WALL / ROOF FRAMIP!G (SEE TABLE) SIGN FACE, CABINET & RACEWAY ATTACHED TO EACH BRACE w/ (2) 3/8" THRU BOLTS (DESIGNED BY OTHERS) ANGLE BRACE FRAMES (BY OTHERS) MAX SPACING OF @ 48" OC (MIN OF 3 BRACES FOR THIS SIGN) TYPICAL SIGN SECTION NOT TO SCALE FASTENER WALL ALLOWABLE MINIMUM # OF CONSTRUCTION LOAD (LB) FASTENERS 3/8" THRU BOLT A307 I FRAME w/ 2X4 BACKER 1 500 2 PER BRACE NOTE: MAXIMUM WEIGHT OF SIGN & CABINET IS 10 LB PER SQ FT FASTENER LOADS SIGN TO FRAME: 1' x 4' X.8 = 3.2 FT2 x 33 PSF / 2 BOLTS = 53 PER FASTENER FRAME TO ROOF: 1' x 4'x .8= 3.2 FT2 x 33 PSF *.5'1.83'= 64 PER FASTENER SIGN INSTALLER AND MANUFACTURER RESPONSIBILITIES: By using this generic sign attachment engineering the owner, manufacturer, and installer accept responsibility to: a. Design sign faces, letters, cabinets, raceways, and attachment brackets according to sign code, building code, and UL b. Verify site conditions match stated wind speed, risk, exposure and topo factors c. Select approved attachment detail, conforming to this generic attachment engineering, by verifying existing wall; which is not the responsibility of this engineer. In fact materials and construction of existing wall is not known at the time of this seal; for this reason various attachment options for various wall construction types are specified. 2. ENGINEER'S SCOPE OF WORK: This design establishes minimum structural requirements for attachment of generic signs to wall based on stated (not verified) wind & gravity loads. a. Size, solid area & weight of generic signs is limited as specified in the generic outline drawing. b. This design is based on C&C wind loads as per ASCE 7-10 sec. 30.5-1 which state that the design wind pressure on a solid sign attached to the wall of a building, where sign is parallel and in contact with the wall, shall be determined using wind pressures for walls per Ch. 30 3. WIND DESIGN DATA: a. Basic Wind Speed, V = 130 MPH (Ult). b. Risk Category II, (MRI = 700 yr.) c. Wind Directonality Factor, Kd = .85, (attached signs) d. Wind Exposure = C, e. Topographic Factor = 1.0, (owner & sign installer must verify) f. Gust -Effect Factor, G = .85, (rigid structure) 29.4.2) 7-10 sec. 29.4.2) g. Internal Pressure Coefficient, Cpi = N/A, (p 4. WIND LOADS FOR COMPONENTS AND CLADDING (determined using ASCE 7-10, Ch. 30) a. Sign Height = 20 ft max b. ASCE 7-10: Fig. 30.5-1, Components and Cladding Method 1 Zone = 1, Effective wind area = 10 ft2, Exposure = C Net Design Pressure (Pnet) = -39.1 psf x 1.40 = -54.7 psf Factored Wind Pressure = Pnet x .6 (Allowable Stress Design) = -33 psf 5. Referenced Code Requirements, ASTM specifications, ACI -318 for reinforced concrete, American Welding Society Code for Welding in Building construction, AISC Specification for Design, Fabrication, and Erection of Structural Steel for Buildings. 6. Wall material specs for attachment only: (Building design and structure is by others.) a. CMU shall be 8" ASTM C90 with fasteners in 1.25" face shell. b. Wood framing shall be 2x4 SPF, 0.42 s.9. w/ fasteners in mid 1/2" of 1.5" edge. c. Cold Formed Steel Framing shall be .033", 36ksi with fasteners in flange. d. Wood Structural Sheathing shall be 7/16" OSB or plywood. e. Concrete shall be 3000 psi min compressive strength. 7. Contractor shall verify all wall materials and construction, dimensions, and conditions in the field before erection and notify the engineer of any discrepancies. 8. FASTENERS: (all allowable loads are per allowable stress design) a. 3/8" A307 STEEL THROUGH BOLTS: (CMU, concrete, frame, and OSB sheathing) - Install w/ 2x4 blocking on back of wall rafters. Allowable tension load = 500 Ib t 14-- 16" 4- - CERTIFICATION: To best of my knowledge, I certify this analysis meets structural requirements of: 6th Edition FLORIDA BUILDING CODE (2017) LIMITATION: Valid for only one sign, at specified location. In case of conflict, structural requirements, scope of work, and installer, mfg, owner responsibilities control. THIS SEAL FOR STRUCTURAL ONLY MARK DISOS E FLPE 915 u xo No 5311 Y: C ; 6" TC 0 Al Tuesday, November 20, 2018 Shark Si ins of NE FL, Inc. Jaguar Power Sports SITE LOCATION: 1221 Mayport Rd Atlantic Beach, FL 32233 Mark Disosway P.E. 163 SW Midtown Place, Suite 103 Lake City, Florida 32025 Phone: (386) 754 - 5419 Fax: (386) 269 - 4871 Email: disoswaydesign@gmail.com =BY:HECKED BY: k Disosway P.E. JOB NUMBER: 181235 DRAWING NUMBER S-1 OF 1 SHEET 3.5' ANGLE BRACE FRAMES (BY OTHERS) MAX SPACING OF @ 24" OC (MIN OF 4 BRACES FOR THIS SIGN) ATTACHED TO ROOF PER TABLE BELOW IR" C: YXIaUY:".L+* � JXPX!'J Ii�ti9k:w's 16" 1. SIGN INSTALLER AND MANUFACTURER RESPONSIBILITIES: accept resp this generic sign installer ecce t res oacco it to: CERTIFICATION: To best of my knowledge, I certify this analysis meets structural attachment engineering the owner, manufacturer, and faces, letters, cabinets, raceways, and attachment brackets according to requirements of: a. Design sign sign code, building code, and UL b. Verify site conditions match stated wind speed, risk, exposure and topo factors to this generic attachment engineering, by 6th Edition FLORIDA c. Select approved attachment detail, conforming of this engineer. In fact materials and BUILDING CODE (2017) verifying existing wall; which is not the responsibility construction of existing wall is not known at the time of this seal; for this reason various construction types are specified. attachment options for various wall LIMITATION: Valid for only one sign, at SIGN FACE, CABINET & RACEWAY 2. ENGINEER'S SCOPE OF WORK: This design establishes minimum structural requirements for ty louttl nas specified location. In case of conflict, structural requlremenis, scope of work, and ATTACHED TO EACH BRACE to outline drawing. & weight of g nlericss gnsed nis limited stated specot ified in he generic attachSiznt f generic signs installer, mfg, owner responsibilities control. wl (2) 3/8" THRU BOLTS BY OTHERS) b. This design is based on C&C wind loads as per ASCE 7-10 sec. 30.5-1 which state that the on a solid sign attached to the wall of a building, where sign is h. 30e Ch_ 30 THIS SEAL FOR STRUCTURAL ONLY (DESIGNED design wind pressure and in contact with the wall, shall be determined using wind pressures for walls per ,-DARK DIS E FLP 915 3. WIND DESIGN DATA: ��t �,. ,_• ' a. Basic Wind Speed, V = 130 MPH (Ult). b. Risk Category II, (MRI = 700 yr.) 4 c. Wind Directonality Factor, Kd = .85, (attached signs) = C, a, rip'„« d. Wind Exposure e. Topographic Factor –1 . 0, (owner &sign installer must verify) f. Gust -Effect Factor, G = .85, (rigid structure) g. Internal Pressure Coefficient, Cpi = N/A, (p erASCE 7 10 sec. 29.4.2) �� �'•" i 4. WIND LOADS FOR COMPONENTS AND CLADDING (determined using ASCE 7-10, Ch. 30) �sep�=, L, ` �� •• •^�� o�,� '•••.••••` ���� Q a. Sign Height = 20 ft max b. ASCE 7-10: Fig. 30.5-1, Components and Cladding - Method 1 = C °'i` l ®N Zone = 1, Effective wind area = 10 ft2, Exposure Q1t t i e e @ Edi Net Design Pressure (Pnet) _ -39.1 psf x 1.40 = -54.7 psf Factored Wind Pressure = Pnet x .6 (Allowable Stress Design) =-33 psf Tuesday, November 20, 2018 5. ReferencedCodeRequirements,ASTMspecifications,ACI-318 for reinforced Society Code for Welding in Building Construction, Shark Signs of Q Q� V' 8 concrete, American Welding AISC Specification for Design, Fabrication, and Erection of Structural Steel for NE FL Inc. Buildings. 6. Wall material specs for attachment only: (Building design and structure is by others.) a. CMU shall be 8" ASTM C90 with fasteners in 1.25" face shell. fasteners in mid 112" of edge. b. Wood framing shall be 2x4 SPF, 0.42 s.g. wl c. Cold Formed Steel Framing shall be .033", 36ksi with fasteners in flange. Sheathing shall be 7/16" OSB or plywood. �' P OW p v Jaguar d. Wood Structural e. Concrete shall be 3000 psi min compressive strength. Q `l JJ 7. Contractor shall verify all wall materials and construction, dimensions, and in the field before erection and notify the engineer of any discrepancies. Sports V �✓ conditions FASTENER THRU ANGLE FRAME TO WALL I ROOF FRAMING (SEE TABLE) allowale stress 8. FASTENERS:. 3/8"A307 STEEL THROUGH BOLble loads are TS (CMU bconcrete,dframe, and OSB sheathing) SIGN FACE, CABINET & RACEWAY - Install wl 2x4 blocking on back of wall rafters. Allowable tension load = 500 Ib SITE LOCATION: o ATTACHED TO EACH BRACE 1221 Mayport Rd iv w/(2) 3/8" THRU BOLTS (DESIGNED BY OTHERS) Atlantic Beach, FL 32233 ANGLE BRACE FRAMES (BY OTHERS) Mark Disosway P.E. o MAX SPACING OF G 24" OC OF 4 BRACES FOR THIS SIGN) 163 SW Midtown Place, Suite 103 (MIN Lake City, Florida 32025 Phone: (386) 754 - 5419 TYPICAL SIGN SSCTION Fax: (386) 269 - 4871 NOT TO SCALE Email: disoswaydesign@gma'Lcom WALL ALLOWABLE MINIMUM # OF DRAWN BY: CHECKED BY: Mark Dlisosway P. . FASTENER FASTENERS CONSTRUCTION LOAD (LB) Suzanne Sabala JOB NUMBER: 318" THRU BOLT A307 FRAME wl 2X4 BACKER 500 2PERBRACE 181235 DRAWING NUMBER NOTE: MAXIMUM WEIGHT OF SIGN & CABINET IS 10 LB PER SQ FT S-1 v FASTENER LOADS SIGN TO FRAME: 3.5' x 2' x .6 = 4.2 FT2 x 33 PSF / 2 BOLTS = 70 PER FASTENER PSF 1.75'1.83'= 293 PER FASTENER OF 1 SHEET FRAME TO ROOF: 3.5'x 2' x.6= 4.2 FT2 x 33 16" 60' FASTENER THRU ANGLE FRAME TO WALL / ROOF FRAMING (SEE TABLE) SIGN FACE, CABINET & RACEWAY C) ATTACHED TO EACH BRACE wit (2) 3/8" THRU BOLTS (DESIGNED BY OTHERS) o-, ANGLE BRACE FRAMES (BY OTHERS) MAX SPACING OF @ 48" OC (MIN OF 3 BRACES FOR THIS SIGN) TYPICAL SIGN SECTION NOT TO SCALE 1. SIGN INSTALLER AND MANUFACTURER RESPONSIBILITIES: By using this generic sign CERTIFICATION: To best of my knowledge, attachment engineering the owner, manufacturer, and installer accept responsibility to: I certify this analysis meets structural ALLOWABLE a. Design sign faces, letters, cabinets, raceways, and attachment brackets according to requirements of: CONSTRUCTION sign code, building code, and UL FASTENERS 3/8" THRU BOLT A307 b. Verify site conditions match stated wind speed, risk, exposure and topo factors 6th Edition FLORIDA 2 PER BRACE c. Select approved attachment detail, conforming to this generic attachment engineering, by verifying existing wall; which is not the responsibility of this engineer. In fact materials and BUILDING CODE (2017) construction of existing wall is not known at the time of this seal; for this reason various attachment options for various wall construction types are specified. SIGN FACE, CABINET & RACEWAY 2. ENGINEER'S SCOPE OF WORK: This design establishes minimum structural requirements for LIMITATION: Valid for only one sign, at specified location. In case of conflict, ATTACHED TO EACH BRACE: attachment of generic signs to wall based on stated (not verified) wind & gravity loads. structural requirements, scope of work, and w/ (2) 3/8" THRU BOLTS a. Size, solid area & weight of generic signs is limited as specified in the generic outline drawing. installer, mfg, owner responsibilities control. (DESIGNED BY OTHERS) b. This design is based on C&C wind loads as per ASCE 7-10 sec. 30.5-1 which state that the THIS SEAL FOR STRUCTURAL ONLY design wind pressure on a solid sign attached to the wall of a building, where sign is parallel and in contact with the wall, shall be determined using wind pressures for walls per Ch. 30 MARK DIrSOS Y, PE 3. WIND DESIGN DATA: 'FLP 915 �' a. Basic Wind Speed, V = 130 MPH (Ult). r AMPM b. Risk Category Il, (MRI = 700 yr.)AN ® a c. Wind Directonality Factor, Kd = .85, (attached signs) d. Wind Exposure = C, e. Topographic Factor = 1.0, (owner & sign installer must verify) h` ' f. Gust -Effect Factor, G = .85, (rigid structure) g. Internal Pressure Coefficient, Cpi = WA, (per ASCE 7-10 sec. 29.4.2) 4. WIND LOADS FOR COMPONENTS AND CLADDING (determined using ASCE 7-10, Ch. 30) a. Sign Height = 20 ft max �,. r r � AT r+� b. ASCE 7-10: Fig. 30.5-1, Components and Cladding - Method 1 14 a�JC Zone = 1, Effective wind area = 10 ft2, Exposure = C,� • �` _>� s ANGLE BRACE FRAMES (BY OTHERS)x,ar Net Design Pressure (Pnet) _ -39.1 psf x 1.40 = -54.7 psf F I MAX SPACING OF @ 48" OC Factored Wind Pressure = Pnet x .6 (Allowable Stress Design) =-33 psf (MIN OF 3 BRACES FOR THIS SIGN) Tuesday, November 20, 2018 ATTACHED TO ROOF PER TABLE BELOW 5. Referenced Code Requirements, ASTM specifications, ACI -318 for reinforced concrete, American Welding Society Code for Welding in Building Construction, Shark Signs of AISC Specification for Design, Fabrication, and Erection of Structural Steel for NE FL, Inc. Buildings. 16" 60' FASTENER THRU ANGLE FRAME TO WALL / ROOF FRAMING (SEE TABLE) SIGN FACE, CABINET & RACEWAY C) ATTACHED TO EACH BRACE wit (2) 3/8" THRU BOLTS (DESIGNED BY OTHERS) o-, ANGLE BRACE FRAMES (BY OTHERS) MAX SPACING OF @ 48" OC (MIN OF 3 BRACES FOR THIS SIGN) TYPICAL SIGN SECTION NOT TO SCALE NOTE: MAXIMUM WEIGHT OF SIGN & CABINET IS 10 LB PER SQ FT FASTENER LOADS SIGN TO FRAME: 1' x 4'x.8 = 3.2 FT2 x 33 PSF 12 BOLTS = 53 PER FASTENER FRAME TO ROOF: 1' x 4'x.8= 3.2 FT2 x 33 PSF *.5'/.83'= 64 PER FASTENER 6. Wall material specs for attachment only: (Building design and structure is by others.) a. CMU shall be 8" ASTM C90 with fasteners in 1.25" face shell. b. Wood framing shall be 2x4 SPF, 0.42 s.g. w/ fasteners in mid 1/2" of 1.5" edge. c. Cold Formed Steel Framing shall be .033", 36ksi with fasteners in flange. d. Wood Structural Sheathing shall be 7/16" OSB or plywood. Jaguar � Power e. Concrete shall be 3000 psi min compressive strength. 7. Contractor shall verify all wall materials and construction, dimensions, and Sports conditions in the field before erection and notify the engineer of any discrepancies. 8. FASTENERS: (all allowable loads are per allowable stress design) a. 3/8"A307 STEEL THROUGH BOLTS: (CMU, concrete, frame, and OSB sheathing) - Install w/ 2x4 blocking on back of wall rafters. Allowable tension load = 500 Ib SITE LOCATION: 1221 Mayport Rd Atlantic Beach, FL 32233 Mark Disosway P.E. 163 SW Midtown Place, Suite 103 Lake City, Florida 32025 Phone: (386) 754 - 5419 Fax: (386) 269 - 4871 Email: disoswaydesign@gmail.cc m DRAWN BY:I CHECKED BY: Suzanne Sabala Mark Disosv,,ay P.E. JOB NUMBER: 181235 DRAWING NUMBER S-1 OF 1 SHEET FASTENER WALL ALLOWABLE MINIMUM # OF CONSTRUCTION LOAD (LB) FASTENERS 3/8" THRU BOLT A307 FRAME w/ 2X4 BACKER 500 2 PER BRACE NOTE: MAXIMUM WEIGHT OF SIGN & CABINET IS 10 LB PER SQ FT FASTENER LOADS SIGN TO FRAME: 1' x 4'x.8 = 3.2 FT2 x 33 PSF 12 BOLTS = 53 PER FASTENER FRAME TO ROOF: 1' x 4'x.8= 3.2 FT2 x 33 PSF *.5'/.83'= 64 PER FASTENER 6. Wall material specs for attachment only: (Building design and structure is by others.) a. CMU shall be 8" ASTM C90 with fasteners in 1.25" face shell. b. Wood framing shall be 2x4 SPF, 0.42 s.g. w/ fasteners in mid 1/2" of 1.5" edge. c. Cold Formed Steel Framing shall be .033", 36ksi with fasteners in flange. d. Wood Structural Sheathing shall be 7/16" OSB or plywood. Jaguar � Power e. Concrete shall be 3000 psi min compressive strength. 7. Contractor shall verify all wall materials and construction, dimensions, and Sports conditions in the field before erection and notify the engineer of any discrepancies. 8. FASTENERS: (all allowable loads are per allowable stress design) a. 3/8"A307 STEEL THROUGH BOLTS: (CMU, concrete, frame, and OSB sheathing) - Install w/ 2x4 blocking on back of wall rafters. Allowable tension load = 500 Ib SITE LOCATION: 1221 Mayport Rd Atlantic Beach, FL 32233 Mark Disosway P.E. 163 SW Midtown Place, Suite 103 Lake City, Florida 32025 Phone: (386) 754 - 5419 Fax: (386) 269 - 4871 Email: disoswaydesign@gmail.cc m DRAWN BY:I CHECKED BY: Suzanne Sabala Mark Disosv,,ay P.E. JOB NUMBER: 181235 DRAWING NUMBER S-1 OF 1 SHEET 16"i 3.5' ANGLE BRACE FRAMES (BY OTHERS) MAX SPACING OF @ 24" OC (MIN OF 4 BRACES FOR THIS SIGN) ATTACHED TO ROOF PER TABLE BELOW 60' r— ;Mhaff o - s 1. SIGN INSTALLER AND MANUFACTURER RESPONSIBILITIES: By using this generic sign attachment engineering the owner, manufacturer, and installer accept responsibility to: a. Design sign faces, letters, cabinets, raceways, and attachment brackets according to sign code, building code, and UL b. Verify site conditions match stated wind speed, risk, exposure and topo factors c. Select approved attachment detail, conforming to this generic attachment engineering, by verifying existing wall; which is not the responsibility of this engineer. In fact materials and construction of existing wall is not known at the time of this seal; for this reason various attachment options for various wall construction types are specified. SIGN FACE, CABINET & RACEWAY 2. ENGINEER'S SCOPE OF WORK: This design establishes minimum structural requirements for ATTACHED TO EACH BRACE attachment of generic signs to wall based on stated (not verified) wind & gravity loads. w/ (2) 3/8" THRU BOLTS a. Size, solid area & weight of generic signs is limited as specified in the generic outline drawing. (DESIGNED BY OTHERS) b. This design is based on C&C wind loads as per ASCE 7-10 sec. 30.5-1 which state that the design wind pressure on a solid sign attached to the wall of a building, where sign is parallel and in contact with the wall, shall be determined using wind pressures for walls per Ch. 30 FASTENER THRU ANGLE FRAME TO WALL /ROOF FRAMING (SEE TABLE) SIGN FACE, CABINET & RACEWAY C) ATTACHED TO EACH BRACE iv w/ (2) 3/8" THRU BOLTS ih (DESIGNED BY OTHERS) ANGLE BRACE FRAMES (BY OTHERS) MAX SPACING OF @24" OC (MIN OF 4 BRACES FOR THIS SIGN) TYPICAL SIGN SECTION NOT TO SCALE NOTE: MAXIMUM WEIGHT OF SIGN & CABINET IS 10 LB PER SQ FT FASTENER LOADS SIGN TO FRAME: 3.5'x 2'x.6 = 4.2 FT2 x 33 PSF / 2 BOLTS = 70 PER FASTENER FRAME TO ROOF: 3.5'x 2'x.6= 4.2 FT2 x 33 PSF1.75'/.83'= 293 PER FASTENER 3. WIND DESIGN DATA: a. Basic Wind Speed, V = 130 MPH (Ult). b. Risk Category Ii, (MR] = 700 yr.) c. Wind Directonality Factor, Kd = .85, (attached signs) d. Wind Exposure = C, e. Topographic Factor = 1.0, (owner & sign installer must verify) f. Gust -Effect Factor, G = .85, (rigid structure) g. Internal Pressure Coefficient, Cpi = WA, (per ASCE 7-10 sec. 29.4.2) 4. WIND LOADS FOR COMPONENTS AND CLADDING (determined using ASCE 7-10, Ch. 30) a. Sign Height = 20 ft max b. ASCE 7-10: Fig. 30.5-1, Components and Cladding - Method 1 Zone = 1, Effective wind area = 10 ft2, Exposure = C Net Design Pressure (Pnet) = -39.1 psf x 1.40 = -54.7 psf Factored Wind Pressure = Pnet x .6 (Allowable Stress Design) = -33 psf 5. Referenced Code Requirements, ASTM specifications, ACI -318 for reinforced concrete, American Welding Society Code for Welding in Building Construction, AISC Specification for Design, Fabrication, and Erection of Structural Steel for Buildings. 6. Wall material specs for attachment only: (Building design and structure is by others.) a. CMU shall be 8" ASTM C90 with fasteners in 1.25" face shell. b. Wood framing shall be 2x4 SPF, 0.42 s.g. w/ fasteners in mid 1/2" of 1.5" edge. c. Cold Formed Steel Framing shall be .033", 36ksi with fasteners in flange. d. Wood Structural Sheathing shall be 7/16" OSB or plywood. e. Concrete shall be 3000 psi min compressive strength. 7. Contractor shall verify all wall materials and construction, dimensions, and conditions in the field before erection and notify the engineer of any discrepancies. 8. FASTENERS: (all allowable loads are per allowable stress design) a. 3/8"A307 STEEL THROUGH BOLTS: (CMU, concrete, frame, and OSB sheathing) - Install w/ 2x4 blocking on back of wall rafters Allowable tension load = 500 Ib FASTENER WALL ALLOWABLE MINIMUM # OF CONSTRUCTION LOAD (LI13) FASTENERS 3/8" THRU BOLT A307 FRAME w/ 2X4 BACKER 500 2 PER BRACE NOTE: MAXIMUM WEIGHT OF SIGN & CABINET IS 10 LB PER SQ FT FASTENER LOADS SIGN TO FRAME: 3.5'x 2'x.6 = 4.2 FT2 x 33 PSF / 2 BOLTS = 70 PER FASTENER FRAME TO ROOF: 3.5'x 2'x.6= 4.2 FT2 x 33 PSF1.75'/.83'= 293 PER FASTENER 3. WIND DESIGN DATA: a. Basic Wind Speed, V = 130 MPH (Ult). b. Risk Category Ii, (MR] = 700 yr.) c. Wind Directonality Factor, Kd = .85, (attached signs) d. Wind Exposure = C, e. Topographic Factor = 1.0, (owner & sign installer must verify) f. Gust -Effect Factor, G = .85, (rigid structure) g. Internal Pressure Coefficient, Cpi = WA, (per ASCE 7-10 sec. 29.4.2) 4. WIND LOADS FOR COMPONENTS AND CLADDING (determined using ASCE 7-10, Ch. 30) a. Sign Height = 20 ft max b. ASCE 7-10: Fig. 30.5-1, Components and Cladding - Method 1 Zone = 1, Effective wind area = 10 ft2, Exposure = C Net Design Pressure (Pnet) = -39.1 psf x 1.40 = -54.7 psf Factored Wind Pressure = Pnet x .6 (Allowable Stress Design) = -33 psf 5. Referenced Code Requirements, ASTM specifications, ACI -318 for reinforced concrete, American Welding Society Code for Welding in Building Construction, AISC Specification for Design, Fabrication, and Erection of Structural Steel for Buildings. 6. Wall material specs for attachment only: (Building design and structure is by others.) a. CMU shall be 8" ASTM C90 with fasteners in 1.25" face shell. b. Wood framing shall be 2x4 SPF, 0.42 s.g. w/ fasteners in mid 1/2" of 1.5" edge. c. Cold Formed Steel Framing shall be .033", 36ksi with fasteners in flange. d. Wood Structural Sheathing shall be 7/16" OSB or plywood. e. Concrete shall be 3000 psi min compressive strength. 7. Contractor shall verify all wall materials and construction, dimensions, and conditions in the field before erection and notify the engineer of any discrepancies. 8. FASTENERS: (all allowable loads are per allowable stress design) a. 3/8"A307 STEEL THROUGH BOLTS: (CMU, concrete, frame, and OSB sheathing) - Install w/ 2x4 blocking on back of wall rafters Allowable tension load = 500 Ib a=JZ N JUao Z = IN. W D tll � t�m00 a ® W-.4 o Z Z W 0 J = U N IT- <1 h- tll L_ LLU_Ls 0 Li_! til j- LL U C5 Ld 5cc UA Lit IC LU CERTIFICATION: To best of my knowledge, I certify this analysis meets structural requirements of: 6th Edition FLORIDA BUILDING CODE (2017) LIMITATION: Valid for only one sign, at specified location. In case of conflict, structural requirements, scope of work, and installer, mfg, owner responsibilities control. THIS SEAL FOR ST CTU L ONLY MARK DIS WAY, P FLIP 3915 • �� `_< No VV1 j �' SS S T T E'• ® °tf� a �tl45 A.i nMy: Tuesday, November 20, 2018 Shark Signs of NE FL, Inc. Jaguar Power Sports SITE LOCATION: 1221 Mayport Rd Atlantic Beach, FL 32233 Mark Disosway P.E. 163 SW Midtown Place, Suite 103 Lake City, Florida 32025 Phone: (386) 754 - 5419 Fax: (386) 269 - 4871 Email: disoswaydesign@gmail.com DRAWN BY: I CHECKED BY: Suzanne Sabala Murk Disosway P.E. JOB NUMBER: 181235 DRAWING NUMBER S-1 OF 1 SHEET 16" ANGLE BRACE FRAMES (BY OTHERS) MAX SPACING OF @ 48" OC (MIN OF 3 BRACES FOR THIS SIGN) ATTACHED TO ROOF PER TABLE BELOW 60' rrreyax: mertryirxrr.kr; nrion ff_WjWUd3l=M SIGN FACE, CABINET & RACEWAY ATTACHED TO EACH BRACE w/ (2) 3/8" THRU BOLTS (DESIGNED BY OTHERS) FASTENER THRU ANGLE FRAME TO WALL/ ROOF FRAMING (SEE TABLE) SIGN FACE, CABINET & RACEWAY AAr o ATTACHED TO EACH BRACE w/ (2) 3/8" THRU BOLTS (DESIGNED BY OTHERS) O% ANGLE BRACE FRAMES (BY OTHERS) MAX SPACING OF @ 48" OC (MIN OF 3 BRACES FOR THIS SIGN) TYPICAL SIGN SECTION NOT TO SCALE FASTENER WALL CONSTRUCTION ALLOWABLE LOAD (LB) MINIMUM # OF FASTENERS 3/8" THRU BOLT A307 FRAME w/ 2X4 BACKER 500 2 PER BRACE NOTE: MAXIMUM WEIGHT OF SIGN & CABINET IS 10 LB PER SQ FT FASTENER LOADS SIGN TO FRAME: 1' x 4' x.8 = 3.2 FT2 x 33 PSF / 2 BOLTS = 53 PER FASTENER FRAME TO ROOF: 1' x 4' x.8= 3.2 FT2 x 33 PSF *.5'/.83'= 64 PER FASTENER 1. SIGN INSTALLER AND MANUFACTURER RESPONSIBILITIES: By using this generic sign attachment engineering the owner, manufacturer, and installer accept responsibility to: a. Design sign faces, letters, cabinets, raceways, and attachment brackets according to sign code, building code, and UL b. Verify site conditions match stated wind speed, risk, exposure and topo factors c. Select approved attachment detail, conforming to this generic attachment engineering, by verifying existing wall; which is not the responsibility of this engineer. In fact materials and construction of existing wall is not known at the time of this seal; for this reason various attachment options for various wall construction types are specified. 2. ENGINEER'S SCOPE OF WORK: This design establishes minimum structural requirements for attachment of generic signs to wall based on stated (not verified) wind & gravity loads. a. Size, solid area & weight of generic signs is limited as specified in the generic outline drawing. b. This design is based on C&C wind loads as per ASCE 7-10 sec. 30.5-1 which state that the design wind pressure on a solid sign attached to the wall of a building, where sign is parallel and in contact with the wall, shall be determined using wind pressures for walls per Ch. 30 3. WIND DESIGN DATA: a. Basic Wind Speed, V = 130 MPH (Ult). b. Risk Category II, (MRI = 700 yr.) c. Wind Directonality Factor, Kd = .85, (attached signs) d. Wind Exposure = C, e. Topographic Factor = 1.0, (owner & sign installer must verify) f. Gust -Effect Factor, G = .85, (rigid structure) g. Internal Pressure Coefficient, Cpi = N/A, (per ASCE 7-10 sec. 29.4.2) 4. WIND LOADS FOR COMPONENTS AND CLADDING (determined using ASCE 7-10, Ch. 30) a. Sign Height = 20 ft max b. ASCE 7-10: Fig. 30.5-1, Components and Cladding - Method 1 Zone = 1, Effective wind area = 10 ft2, Exposure = C Net Design Pressure (Pnet) = -39.1 psf x 1.40 = -54.7 psf Factored Wind Pressure = Pnet x .6 (Allowable Stress Design) = -33 psf 5. Referenced Code Requirements, ASTM specifications, ACI -318 for reinforced concrete, American Welding Society Code for Welding in Building Construction, AISC Specification for Design, Fabrication, and Erection of Structural Steel for Buildings. 6. Wall material specs for attachment only: (Building design and structure is by others.) a. CMU shall be 8" ASTM C90 with fasteners in 1.25" face shell. b. Wood framing shall be 2x4 SPF, 0.42 s.g. w/ fasteners in mid 1/2" of 1.5" edge. c. Cold Formed Steel Framing shall be .033", 36ksi with fasteners in flange. d. Wood Structural Sheathing shall be 7/16" OSB or plywood. e. Concrete shall be 3000 psi min compressive strength. 7. Contractor shall verify all wall materials and construction, dimensions, and conditions in the field before erection and notify the engineer of any discrepancies. 8. FASTENERS: (all allowable loads are per allowable stress design) a. 3/8"A307 STEEL THROUGH BOLTS: (CMU, concrete, frame, and OSB sheathing) - install w/ 2x4 blocking on back of wall rafters. Allowable tension load = 500 Ib '_t�Z) CERTIFICATION: To best of my knowledge, I certify this analysis meets structural requirements of: 6th Edition FLORIDA BUILDING CODE (2017) LIMITATION: Valid for only one sign, at specified location. In case of conflict, structural requirements, scope of work, and installer, mfg, owner responsibilities control. THIS SEAL FQR, ST TURAL ONLY ,AR, Dl SWA , E ��®t•[F E53915 ♦ 5" Nct x s — r�s 40�® VIN Tuesday, November 20, 2018 Shark Signs of NE FL, Inc. Jaguar Power Sports SITE LOCATION: 1221 Mayport Rd Atlantic Beach, FL 32233 Mark Disosway P.E. 163 SW Midtown Place, Suite 103 Lake City, Florida 32025 Phone: (386) 754 - 5419 Fax: (386) 269 - 4871 Email: disoswaydesign@gmail.com DRAWN BY: CHECKED BY: Suzanne Sabala Mark Diso;sway P.E. JOB NUMBER 181235 DRAWING NUMBER S-1 OF 1 SHEET