Loading...
1660 ATLANTIC BEACH DR RES18-0246 (2) CITY OF ATLANTIC BEACH it 800 Seminole Road Atlantic Beach,Florida 32233 REVISION REQUEST/CORRECTIONS TO PLAN REVIEW COMMENTS Date 12/11/2018 Revision to Issued Permit Corrections to Comments Permit#RES -Qay(-Q- Project Address I X00 �j 4'����((„' Lri' ij€ Contractor/Contact Name Audrey Regnier Phone 904.595.5243 Email aregnier@tollbrothers.com Description of Proposed Revision/Corrections: Permit Fee Due $ Revised manuals J & S; original permit set incorrect Additional Increase in Building Value$ Additional S.F. By signing below,I Audrey Regnier affirm the Revision is inclusive of the proposed changes. (printed name) 0 & J2' 12/11/2018 Signature of Cci ractor/Agent( ntractor must sign if increase in valuation) Date (Office Use Only) Approved Denied Not Applicable to Department Revision/Plan Review Comments Lof)/ac/ /v i Z/t - 7010 cop/ I fey GP-0-e Department Review Required: rt ntng ?t Zoning eviewed By Tree Administrator Public Works Public Utilities )2 - t —c -er Public Safety Date Fire Services REVIc.... !CL7-‘1 ri voth Project Summary EP# QHS/ef - (2/( e: Lot 150 ABCC iiit L'lr}F� (Rest of House) DATE /2- /„/ /a: By: Saldie Guintivano McGowan's Heating & Air Condi i my 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie@rncgowansac.corn Web:www.mcgowansac.com License:CMC1... Project Information For: a,Toll Brothers, Inc. 160 C OFFICE COPY 160 Capepe May Ave., Ponte Vedra, FL 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Notes: San Tropez Desi• n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 24 °F Daily range M Relative humidity 50 Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 28193 Btuh Structure 23311 Btuh Ducts 3375 Btuh Ducts 4185 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 31569 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load Btuh Method Blower door Latent Cooling Equipment Load Sizing Shielding/stories 3(partial)/2 Pressure/AVF 50 Pa/4081 cfm Structure 6369 Btuh Ducts 743 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 2305 2305 E ipment latent load /"- _-33tuh Volume (ft') 21875 21875 Air changes/hour 0.61 0.38 E.uipment Tnta Sen+Lat) tuh Equiv. AVF(cfm) 223 140 Req.total capacity at 0.70 SH 3.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB0420000A0 Cond CH14NB0420000A0 AHRI ref 9162578 Coil FB4CNP042L AHRI ref 9162578 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 28000 Btuh Heating output 41000 Btuh @ 47°F Latent cooling 12000 Btuh Temperature rise 30 °F Total cooling 40000 Btuh Actual air flow 1225 cfm Actual air flow 1225 cfm Air flow factor 0.039 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.79 Capacity balance point=26°F Backup: Input=9 kW, Output=31569 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 'r wrightoft- 2018-Dec-1022:46:45 ..A. - -- Comfort Builder by Wrightsoft 18.0.31 RSU03444 Page 1 ...top Tropez 3530 Right NE-Lot 150 ABCC.rup Calc=MJ8 Front Door faces:NE Project SummaryJob: Lot 150ABCC -tea. J Date: t j I 2nd F! By: Sadie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie©mcgowansac.com Web:www.mcgowansac.com License:CMC1... Pro'ect Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, FL 32081 Phone: (904)217-0739 Fax: (904) 814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Notes: San Tropez Desi•n Information Weather: Jacksonville NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 24 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 11668 Btuh Structure 9280 Btuh Ducts 1575 Btuh Ducts 2000 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 13243 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 12750 Btuh Method Blower door Latent Cooling Equipment Load Sizing Shielding/stories 3(partial)/2 Pressure/AVF 50 Pa/4081 cfm Structure 4421 Btuh Ducts 385 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1224 1224 quipment latent load _ANA, Btuh Volume(fta) 11054 11054 Air changes/hour 0.80 0.50 Equipment Total Load (Sen+Lat) =C'r 33tuh Equiv.AVF (cfm) 148 93 Req.total capacity at u.70-511 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model CH14NB0180000A0 Cond CH14NB0180000A0 AHRI ref 9162108 Coil FB4CNP018L AHRI ref 9162108 Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 12460 Btuh Heating output 17600 Btuh @ 47°F Latent cooling 5340 Btuh Temperature rise 27 °F Total cooling 17800 Btuh Actual air flow 593 cfm Actual air flow 593 cfm Air flow factor 0.045 cfm/Btuh Air flow factor 0.053 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.70 Capacity balance point=26°F Backup: Input=4 kW, Output= 13243 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wsot' rightf2018-Dec-10 22:46:45 '� - .. -. --._ Comfort Builder by Wrightsoft 18.0.31 RSU03444 Page 2 A ...toplSan Tropez 3530 Right NE-Lot 150 ABCC.rup Calc=MJ8 Front Door faces:NE ter N First Floor I i BREAKFAS- 6 x 10 12x6 ! 6" m.wic2 7" MASTER SUITE 16x16 8x4 10x6 4" 0oIII 160x6 12" ..MI Ir • FAMILY ROOK 6x10 8x411 6., 4" R- Riser 111 KITCHEN litl Mwic 12„ , • m.batt 12x6 12 12. • 1oe ,1 18x24 MI , , 4x8 4x4 „Fan r 15"Ta I _ y 4 we •' '•' 1"D.B - 10 x 6 O 12" D ,J 5" .:ntr\ 3" Fan N\ 8 x 4 , 3"Fan Ll 4' 8x4 4" bath 10 x 10 17x20x20 1" D.B Transfer over the door 14x6 12x6 . 8' 7" S/W GARAGE FOYER/STAIR; Dininn I I Job #: Lot 150 ABCCMcGowan's Heating & Air Conditionin Scale: 1 : 92 Performed by Saldie Guintivano for: Page 1 Steve Marten 11320 E.Phillips Parkway Dr. Comfort Builder by Wrightsoft 160 Cape May Ave. Jacksonville,FL 32256 18.0.31 RSU03444 Ponce Vedra,FL 32081 Phone:904-278-0339 Fax:904-278-0366 2018-Dec-10 22:48:31 Phone.(904)217-0217-0739 Fax.(904)814-8173 www.tollbrothers.com smarten@tollbrothersinc.com www.mcgowansac.com Saldie@mcgowansac.com ...3530 Right NE-Lot 150 ABCC.n. 4 N 2ND FL t • t t - , 3"Fan O I\ bath 2 aJ 8x4 4' bed 3 bed 2 12x6 4x8 12x6 7 , 4 7„ �•� 12x12 p.74 14" 91x12 9" sin' . tri �a• ■ ■ Ret Riser 10x6 ." # 4,T Ox. AA 1 ,'12" 6" ,. 12„ 6" 4 x 8 Ilk i 4' A/C 18x16x48 Plenum 9"pitch 10" 141 on the 18"side LOFT • 8 x 4 ' L 12 " 4" i 14 ' 16x16 WIC ... '• ., 12" a , 4x8 attic 4., I► 2.1.J Pa R•+ 3" Fan 12x12 12x6 BATH 3 7„ Ret 'iser 10x6 6" BEDROOM OPEN TO BELOV Job#: Lot 150 ABCCMcGowan's Heating & Air Conditionin Scale: 1 : 92 Performed by Saldie Guintivano for: Page 2 Steve Merten 11320 E.Phillips Parkway Dr. Comfort Builder by Wrightsoft 160 Cape May Ave. Jacksonville,FL 32256 18.0.31 RSU03444 Ponte904)Vedra,FL 32081 Phone:904-278-0339 Fax:904-278-0366 2018-Dec-10 22:48:31 217-0739Phone:(904) Fax:(904)814-8173 www.tolibrothers.corn smerten@tolibrothersinc.corn www.mcgowansac.com saldie@mcgowansac.com ...3530 Right NE-Lot 150 ABCC.ri Equipment Summary Job: Lot 150 ABCC fit): Date: (rit�'tt9 (Rest of House) By: Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie@mcgowansac.com Web:www.mcgowansac.com License:CMC1... Pro"ect Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, FL 32081 Phone: (904) 217-0739 Fax: (904) 814-8173 Web: www.tollbrothers.com Email: smerten@tollbrothersinc.com Base System: Heat pump: Carrier CARRIER CH14NB0420000A0 Coil Model: FB4CNP042L Total cooling capacity=40000 Btuh, 11.5 EER, 14 SEER, Sound level=0.0, 8.2 HSPF At 17°F: Heating Capacity= 25200 Btuh, COP=2.50 At 47°F: Heating Capacity= 41000 Btuh, COP=3.62 Ca pacity balance point=26°F,Economic balance point=-99°F Backup: Input=9 kW, Output=31569 Btuh, 100 AFUE Water Heating: Gas instantaneous 0 gal tank, 100 MBtuh input, 0.82 EF Warranties: Features: Investment 1: Cooling: Coil Model: Total cooling capacity=0 Btuh, 0 SEER, Sound Level=0.0 Heating: Input=0 Btuh, Output=0 Btuh, 80 AFUE Water Heating: Gas conventional 40 gal tank, 36 MBtuh input, 0.60 EF Warranties: Features: wrightsott 2018-Dec-10 22:46:45 Comfort Builder by Wrightsoft 18.0.31 RSU03444 Page 1 ...top\San Tropez 3530 Right NE-Lot 150 ABCC.rup Calc=MJ8 Front Door faces:NE Equipment Summary Date: Lot 150ABCC (Rest of House) By: Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie@mcgowansac.com Web:www.mcgowansac.com License:CMC1... Pro'ect Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, FL 32081 Phone: (904) 217-0739 Fax: (904) 814-8173 Web:www.tollbrothers.com Email: smerten©tollbrothersinc.com Investment 2: Cooling: Coil Model: Total cooling capacity=0 Btuh, 0 SEER, Sound Level=0.0 Heating: Input=0 Btuh, Output=0 Btuh, 80 AFUE Water Heating: Gas conventional 40 gal tank, 36 MBtuh input, 0.60 EF Warranties: Features: Investment 3: Cooling: Coil Model: Total cooling capacity=0 Btuh, 0 SEER, Sound Level=0.0 Heating: Input=0 Btuh, Output=0 Btuh, 80 AFUE Water Heating: Gas conventional 40 gal tank, 36 MBtuh input, 0.60 EF Warranties: Features: i- wr ghta&otta. 2018-Dec-10 22:46:45 Comfort Builder by Wrightsoft 18.0.31 RSU03444 Page 2 ...top\San Tropez 3530 Right NE-Lot 150 ABCC.rup Calc=MJ8 Front Door faces:NE Equipment Summary Date: Lot 150ABCC { , � 2nd F� By: Saldie Guintivano McGowan's s Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie@mcgowansac.cor Web:www.mcgowansac.com License:CMC1... Pro'ect Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, FL 32081 Phone: (904) 217-0739 Fax: (904) 814-8173 Web:www.tollbrothers.com Email: smerten©tollbrothersinc.com Base System: Heat pump: Carrier CARRIER AIR CONDITIONING CH14NB0180000A0 Coil Model: FB4CNP018L Total cooling capacity= 17800 Btuh, 11.5 EER, 14 SEER, Sound level=0.0, 8.2 HSPF At 17°F: Heating Capacity= 10400 Btuh, COP=2.40 At 47°F: Heating Capacity= 17600 Btuh, COP=3.72 Capacity balance point=26°F,Economic balance point=-99°F Backup: Input=4 kW, Output= 13243 Btuh, 100 AFUE Warranties: Features: Investment 1: Cooling: Coil Model: Total cooling capacity=0 Btuh, 0 SEER, Sound Level=0.0 Heating: Input=0 Btuh, Output=0 Btuh, 80 AFUE Water Heating: Gas conventional 40 gal tank, 36 MBtuh input, 0.60 EF Warranties: Features: Wrights°ft. 2018-Dec-10 22:46:45 ,.,. •-, - - Comfort Builder by Wrightsot 18.0.31 RSU03444 Page 3 ...top\San Tropez 3530 Right NE-Lot 150 ABCC.rup Calc=MJ8 Front Door faces:NE ( Equipment Summary Jae: Lot 150 ABCC reafKG�tFt€-,� 2nd Fl By: Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie@mcgowansac.com Web:www.mcgowansac.com License:CMC1... Pro'ect Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, FL 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Investment 2: Cooling: Coil Model: Total cooling capacity=0 Btuh, 0 SEER, Sound Level=0.0 Heating: Input=0 Btuh, Output=0 Btuh, 80 AFUE Water Heating: Gas conventional 40 gal tank, 36 MBtuh input, 0.60 EF Warranties: Features: Investment 3: Cooling: Coil Model: Total cooling capacity=0 Btuh, 0 SEER, Sound Level=0.0 Heating: Input=0 Btuh, Output=0 Btuh, 80 AFUE Water Heating: Gas conventional 40 gal tank, 36 MBtuh input, 0.60 EF Warranties: Features: wrightscaft- 2018-Dec-10 22:46:45 Comfort Builder by Wrightsoft 18.0.31 RSU03444 Page 4 ...top\San Tropez 3530 Right NE-Lot 150 ABCC.rup Calc=MJ8 Front Door faces:NE Duct System Summary Job: Lot 150 ABCC �± Date: 1f Oowa (Rest of House) By: Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax:904-278-0366 Email:saldie©mcgowansac.com Web:www.mcgowansac.com License:CMC1... Project Information For: Steve Meilen,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, FL 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.212/0.178 in H2O 0.212/0.178 in H2O Lowest friction rate 0.071 in/100ft 0.071 in/100ft Actual air flow 1225 cfm 1225 cfm Total effective length (TEL) 548 ft Supply Branch Detail Table Design Htg Cig Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln(ft) Trunk BREAKFAST h 3723 144 127 0.090 7.0 Ox 0 VIFx 57.0 180.0 st2 Dining h 6167 239 215 0.074 8.0 Ox 0 VIFx 63.6 225.0 st5 FAMILY ROOM-A c 3300 -85 147 0.094 6.0 Ox 0 VIFx 45.0 180.0 st2 FAMILY ROOM-B c 3300 85 147 0.090 6.0 Ox 0 VIFx 55.8 180.0 st2 FOYER/STAIRS-A h 5528 215 154 0.071 7.0 Ox 0 VIFx 67.5 230.0 st5 KITCHEN c 2693 118 120 0.073 7.0 Ox 0 VIFx 65.0 225.0 st5 MASTER SUITE-A c 1634 55 73 0.101 6.0 Ox 0 VIFx 39.5 170.0 st6 MASTER SUITE-B c 1634 55 73 0.108 6.0 Ox 0 VIFx 31.7 165.0 st6 Mwic c 1 0 0 0.105 4.0 Ox 0 VIFx 32.8 170.0 st6 bath h 254 10 6 0.071 4.0 Ox 0 VIFx 68.2 230.0 st5 Indry c 699 10 31 0.106 4.0 Ox 0 VIFx 29.8 170.0 st6 m.bath h 2712 105 81 0.112 5.0 Ox 0 VIFx 24.9 165.0 st6 m.wic 2 h 2524 98 43 0.108 4.0 Ox 0 VIFx 32.1 165.0 st6 pantry c 62 2 3 0.075 4.0 Ox 0 VIFx 58.9 225.0 st5 we h 149 6 4 0.111 4.0, Ox 0 VIFx 25.7 165.0 st6 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 896 920 0.071 861 14.0 0 x 0 VinIFIx st5 Peak AVF 583 499 0.071 742 12.0 0 x 0 VinIFIx st2 st6 Peak AVF 329 305 0.101 418 12.0 0 x 0 VinIFIx st3 st3 Peak AVF 329 305 0.101 418 12.0 0 x 0 VinIFIx - wrightsoft 2018-Dec-10 22:46:45 ;+ .. .- .. _ ,., Comfort Builder by Wrightson 18.0.31 RSU03444 Page 1 J ...top\San Tropez 3530 Right NE-Lot 150 ABCC.rup Calc=MJ8 Front Door faces:NE Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb8 Ox 0 737 838 249.5 0.071 784 14.0 Ox 0 VIFx rt3 rsb3 Ox 0 488 387 102.2 0.174 622 12.0 Ox 0 VIFx Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt3 Peak AVF 737 838 0.071 600 16.0 0 x 0 ViniFlx W 1'IE,�lf'Yt9Oft"" 2018-Dec-10 22:46:45 ,......x., ... ._. ., _-.. Comfort Builder by Wrightsoft 18.0.31 RSU03444 Page 2 ACLA ...top\San Tropez 3530 Right NE-Lot 150 ABCC.rup Calc=MJ8 Front Door faces:NE Duct System Summary Job: Lot 150 ABCC �" Date: ifiAI --'ffiii:1 2nd Fl By: Saldie Guintivano McGowan's Heating & Air Conditioning 11320 E.Phillips Parkway Dr.,Jacksonville,FL 32256 Phone:904-278-0339 Fax 904-278-0366 Email:saldie@mcgowansac.corn Web:www.mcgowansac.com License:CMC1... Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, FL 32081 Phone: (904) 217-0739 Fax: (904) 814-8173 Web:www.tollbrothers.com Email: smerten@tollbrothersinc.com Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.11 in H2O 0.11 in H2O Available static pressure 0.39 in H2O 0.39 in H2O Supply/return available pressure 0.235/0.155 in H2O 0.235/0.155 in H2O Lowest friction rate 0.105 in/100ft 0.105 in/100ft Actual air flow 593 cfm 593 cfm Total effective length (TEL) 371 ft Supply Branch Detail Table I Design Htg ' Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk NC h 1107 50 35 0.158 4.0 Ox 0 VIFx 8.5 140.0 st1 BATH 3 h 1228 55 38 0.146 4.0 Ox 0 VIFx 16.5 145.0 st1 BEDROOM 4 c 1999 104 105 0.143 7.0 Ox 0 VIFx 19.5 145.0 st1 LOFT h 656 29 25 0.148 6.0 Ox 0 VIFx 13.6 145.0 st1 LOFT-A h 656 29 25 0.108 6.0 Ox 0 VIFx 28.7 190.0 st4 LOFT-B h 656 29 25 0.107 6.0 Ox 0 VIFx 34.0 185.0 st4 WC 4 c 70 3' 4 0.149 4.0 Ox 0 VIFx 13.1 145.0 st1 bath 2 h 555 25 22 0.105 4.0 Ox 0 VIFx 38.5 185.0 st4 bed 2 c 2537 121 133 0.109 7.0 Ox 0 VIFx 30.4 185.0 st4 bed 3 c 3338 145 176 0.145 7.0 Ox 0 VIFx 16.9 145.0 st1 sinks c 101 , 3 5 0.142 4.0 Ox 0 VIFx 20.6 145.0 st1 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 204 206 0.105 377 10.0 0 x 0 VinIFIx st1 st1 Peak AVF 593 593 0.105 755 12.0 0 x 0 VinlFlx wriglhtsoft- 2018-Dec-10 22:46:45 .. .. .. .. . ... . Comfort Builder by Wrightson 18.0.31 RSU03444 Page 3 ...top\San Tropez 3530 Right NE-Lot 150 ABCC.rup Calc=MJ8 Front Door faces:NE Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb11 Ox 0 82 64 135.9 0.114 104 12.0 Ox 0 VIFx ill rb14 Ox 0 175 181 147.3 0.105 409 9.0 Ox 0 VIFx ill rb13 Ox 0 178 206 143.7 0.108 467 9.0 Ox 0 VIFx rt1 rb12 Ox 0 159 143 139.6 0.111 359 9.0 Ox 0 VIFx rtl Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rtl Peak AVF 593 593 0.105 555 14.0 0 x 0 ViniFlx * W r i 7t5Of ' 2018-Dec-10 22:46:45 Ati a Comfort Builder by Wrightson 18.0.31 RSU03444 Page 4 .' ...top\San Tropez 3530 Right NE-Lot 150 ABCC.rup Calc=MJ8 Front Door faces:NE