Loading...
315 AHERN ST RES17-0271 ENERGY EFF CODE l i)h@IN-n - • i FORM R405-2017 Gs t 7 - CD z7 t FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1902 Right`)--A Builder Name: Street: Permit Office: City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Jacksonville County:: Duval(Florida Climate Zone 2) 1. New Construction or existing New(From Plans) 9. Wall Types(1878.0 sqft.) Insulation Area a.Frame-Wood,Exterior R=19.0 1626.00 ft2 2. Single family or multiple family Single-family b. Frame-Wood,Adjacent R=19.0 252.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types (982.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=19.0 982.00 ft2 R= ft2 6. Conditioned floor area above grade(ft2) 1902 b.N/A.N/A R= ft2 Conditioned floor area below grade(ft2) 0 11. Ducts R ft2 a.Sup:Windows(207.6 sqft.) Description Area Attic,Ret:Attic,AH:Main 6 290 a. U-Factor: Dbl,U=0.36 207.60 ft2 SHGC: SHGC=0.31 12.Cooling systems kBtu/hr Efficiency b. U Factor: N/A ft2 a.Central Unit 41.0 SEER:15.50 SHGC: c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor N/A ft2 a. Electric Heat Pump 41.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.933 ft. 14.Hot water systems Area Weighted Average SHGC: 0.310 a. Electric Cap:55 gallons 8. Floor Types (956.0 sqft.) Insulation Area EF:0.950 a.Floor over Garage R=19.0 615.00 ft2 b. Conservation features b.Slab-On-Grade Edge Insulation R=0.0 237.00 ft2 None c.other(see details) R= 104.00 ft2 15.Credits Pstat Total Proposed Modified Loads: 52.54 PASS Glass/Floor Area: 0.109 Total Baseline Loads: 54.66 hereby certify that the plans and specifications covered by Review of the plans and o��1iE ST,q?�o this calculation are in compliance with the Florida Energy specifications covered by this ,, , ,�, Code. calculation indicates compliance =c,) 'o ,, ,`,,;,�' with the Florida Energy Code. is ,=u,i,,. ;i O 7/4-4-42- Before construction is completed .....4...,,,,-,''‘,2° "''l c. • PREPARED BY: - - cd -...n-- i o DATE: ,0 this building will be inspected for • 0,, •i 'r, ., !a i - compliance with Section 553.908 * , I hereby certify that this building, as signe is in ompliance Florida Statutes. ''•. " O ..' with the Florida Energy Co 1 .•••` OWNER/AGENT:-- _ _.. - BUILDING OFFICIAL: _ -- . (' S • DATE: - - Y/ / DATE: f - - Compliance requires certification by the air handler unit manufacturer that the air handler enclosu qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402. . ill this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). /� %-,1 ,off 3/29/2018 12:41 PM EnergyGauge®Ener Gau e®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 PROJECT Title: 1902 Right Bedrooms: 3 Address Type: Lot Information Building Type: User Conditioned Area: 1902 Lot# 5A Owner Name: Total Stories: 3 Block/Subdivision: Ahem Townhomes #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: Permit Office: Cross Ventilation: No County: Duval Jurisdiction: Whole House Fan: No City,State,Zip: Atlantic Beach, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT 32 93 70 75 1281 49 Medium - BLOCKS Number Name Area Volume 1 Block1 1902 17118 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1902 17118 Yes 4 3 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Raised Floor Main ____ ____ 104 ft2 19 0 0 1 2 Slab-On-Grade Edge Insulatio Main 64 ft 0 237 ft2 ____ 0 0 1 - 3 Floor over Garage Main ____ ____ 615 ft2 19 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Flat Gravel 985 ft2 42 ft2 Medium 0.65 N 0.9 No 0 4.8 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 No attic Vented 300 982 ft2 N N 3/29/2018 12:41 PM EnergyGauge8 USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4 r FORM R405-2017 CEILING _V # Ceiling Type - Space - R-Value _ Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 19 Blown 982 ft' 0.1 Wood WALLS ✓_# nmt TpWall Ty{Ie Adjacent - _Cavity Width Height Sheathing Framing Solar Below Space R-VValue----Ft__In-- tIn - Area R-Value Fraction-. Absor. Grarie%_ ------- _ 1 W Exterior Frame-Wood Main 19 21 0 10 0 210.0 ft' 0 0.25 0.5 0 _ 2 W Exterior Frame-Wood Main 19 67 0 9 0 603.0 ft2 0 0.25 0.5 0 3 E Exterior Frame-Wood Main 19 18 0 10 0 180.0 ft' 0 0.25 0.5 0 _ 4 E Exterior Frame-Wood Main 19 70 4 9 0 633.0 ft' 0 0.25 0.5 0 5 - Garage Frame-Wood Main 19 28 0 9 0 252.0 ft2 0 0.25 0.01 0 DOORS V # Ornt Door Type Space Storms U-Value Ft Width Height Area In Ft In 1 E Insulated Main None .39 3 8 24 ft2 2 - Insulated Main None .39 2 10 6 10 19.4 ft' WINDOWS Orientation shown is the entered,Proposed orientation. / Wall Overhang V #_ Omt ID Frame _ Panes NFRC U-Factor SH_GC Imp Area Depth Separation Int Shade Screening 1 W 1 Vinyl Low-E Double Yes 0.36 0.31 N 54.0 ft2 2 ft 0 in 2 ft 0 in Drapes/blinds None - 2 W 2 Vinyl Low-E Double Yes 0.36 0.31 N 16.5 ft2 4 ft 0 in 2 ft 0 in Drapes/blinds None - 3 W 2 Vinyl Low-E Double Yes 0.36 0.31 N 7.1 ft' 4 ft 0 in 2 ft 0 in Drapes/blinds None - 4 W 2 Vinyl Low-E Double Yes 0.36 0.31 N 4.0 ft' 4 ft 0 in 2 ft 0 in Drapes/blinds None - 5 W 2 Vinyl Low-E Double Yes 0.36 0.31 N 10.0 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 6 W 2 Vinyl Low-E Double Yes 0.36 0.31 N 4.0 ft' 0 ft 0 in 0 ft 0 in Drapes/blinds None - 7 E 3 Vinyl Low-E Double Yes 0.36 0.31 N 30.0 ft2 2 ft 0 in 2 ft 0 in Drapes/blinds None 8 E 3 Vinyl Low-E Double Yes 0.36 0.31 N 82.0 ft' 1 ft 6 in 1.600000 Drapes/blinds None GARAGE V_ # _ Floor Area Ceiling Area Exposed Wall Perimeter - Avg.Wall Height Exposed Wall Insulation 1 615 ft' 615 ft2 26ft 9ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 1997.1 109.64 206.19 .4286 7 3/29/2018 12:41 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4 y - "" FORM R405-2017 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts —__ 1 Electric Heat Pump/ Split HSPF:8.5 41 kBtu/hr 1 sys#1 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15.5 41 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM _ # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 55 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume—_FEF 2 None None f DUCTS / — Supply –Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 290 ft2 Attic 125 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling Jan Feb Mar 1)(1 A r [ ]Ma r]Jun [X]Jul [[X]Au [X]Se Oct Nov Xl DecHeating .X)Jan X Feb r [Mar Apr [ ]May ]Jun [ ]Jul ]Aug [ ]SepOct 'X)Venting Jan Feb X Mar Apr [ )May ]Jun [ ]Jul ]Aug— [ ]Se [X]Oct 'X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 68 66 66 66 68 68 68 68 68 68 66 Heating(WEH) AM 68 68 66 66 66 66 68 68 68 68 66 68 68 68 68 68 66 66 3/29/2018 12:41 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4 l 1 i FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. , Atlantic Beach, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area a. Frame-Wood,Exterior R=19.0 1626.00 ft2 2. Single family or multiple family Single-family b.Frame Wood,Adjacent R=19.0 252.00 ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic(Vented) R=19.0 982.00 ft2 6. Conditioned floor area(ft2) 1902 b.N/A R= ft2 c.N/A R= ft2 7. Windows`* Description Area 11.Ducts R ft2 a. U-Factor: Dbl,U=0.36 207.60 ft2 a.Sup:Attic,Ret:Attic,AH:Main 6 290 SHGC: SHGC=0.31 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 41.0 SEER:15.50 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 41.0 HSPF:8.50 Area Weighted Average Overhang Depth: 1.933 ft. Area Weighted Average SHGC: 0.310 8. Floor Types Insulation Area 14. Hot water systems Cap:55 gallons a.Floor over Garage R=19.0 615.00 ft2 a. Electric EF:0.95 b.Slab-On-Grade Edge Insulation R=0.0 237.00 ft2 b. Conservation features c.other(see details) R= 104.00 ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building "4�M SrgT••�.,. Construction through the above energy saving features which will be installed (or exceeded) a•'��:...l,;, p in this home before final ins• - ion. Otherwise, a new EPL Display Card will be completed •",' i;, . , ••. based on installed Code •• -•liant features. •p' :�;_ -:'-:•:.--,:.•••••' ��� l-`�O ' •' i , ,i'• a• Builder Signature: / .�r Date: :L''. -� 'al Address of New Home:3/ S 4,/.-,p 47. _ City/FL 7 1 Aj'c ........„1,'...-.-:...� ........ w`� .... . -- -°D c r' `Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/29/2018 12:41 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 , 2017-AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: 1902 Right Builder Name: Street: Permit Office: City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Jacksonville COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped g ed ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover elates and walls or ceilings. a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 3/29/2018 12:42 PM EnergyGauge®USA-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 A r �. FORM R405-2017 Envelope Leakage Test Report Performance FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Performance Method Project Name: 1902 Right Builder Name: Street: Permit Office: City,State,Zip: Atlantic Beach, FL, Permit Number: Design Location: FL,Jacksonville Jurisdiction: Cond.Floor Area:: 1902 sq.ft. Cond.Volume: 17118 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: Single or Multi Point Test Data Required ACH(50)from HOUSE PRESSURE FLOW: FORM R405-2017 : 1 Pa cfm 2 Pa cfm Tested ACH(50) * : 3 Pa cfm *Tested leakage must be less than or equal to the 4 Pa cfm required ACH(50)shown on Form R405-2017 for 5 Pa cfm this building. If the tested ACH(50) is less than 3 the building must have a mechanical ventilation 6 Pa cfm system. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2...Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Testing shall be conducted by either OIE performance results demonstrate compliance individuals as defined in Section � =' 0�; with Florida Energy Code requirements in 553.993(5)or(7), Florida Statutes or .y4,4,•,�'' ,t� �+ accordance with Section R402.4.1.2. individuals licensed as set forth in :u,,, 'a:; '0, �C Section 489.105(3)(f), (g), or(i)or an ''' -• c approved third party.A written report of ; O SIGNATURE: the results of the test shall be signed by the third party conducting the test and provided to the code official. Cob PRINTED NAME: BUILDING OFFICIAL: DATE: DATE: 3/29/2018 12:42 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 Pr Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: Permit Number: Atlantic Beach , FL, MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level(EPL)display card(Mandatory).The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 InstallationThe components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3. Interior doors,if installed at the time of the test,shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems,if installed at the time of the test,shall be turned off. 6. Supply and retum registers,if installed at the time of the test,shall be fully open. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air leakagd.ndows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 3/29/2018 12:42 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 1 of 5 ! n M MANDATORY REQUIREMENTS - (Continued) R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1 Controls. SECTION R403 SYSTEMS R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered duds or plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or (7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing(Mandatory).Ducts shall be pressure tested to determine air leakage by one of the following methods: 1, Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory)Heated water circulation systems shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems.Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 3/29/2018 12:42 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017)Complian Page 2 of 5 j - Y MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 A inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies(Mandatory). R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main bumer(s)of combustion types of service water-heating systems to be turned off. R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation including:Natural, Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole-house mechanical ventilation system fan efficacy.When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3• If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10 otherwise. R403.7 Heating and cooling equipment(Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMUN (CFM) (CFM/WATT) (CFM) Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom,utility room 10 1.4 cfm/watt <90 Bathroom,utility room 90 2.8 cfm/watt Any For SI: 1 cfm=28.3 L/min. a. When tested in accordance with HVI Standard 916 3/29/2018 12:42 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8°C). R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches.Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously buming pilot lights. 3/29/2018 12:42 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 4 of 5 • R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas(Mandatoryae energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception:Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory)Fuel gas lighting systems shall not have continuously buming pilot lights. 3/29/2018 12:42 PM EnergyGauge®USA-FlaRes2017 -FBC 6th Edition(2017) Complia Page 5 of 5 wrightsoft Manual S ComplianceReport Re ort Job: Lot 5AAT Entire House Bate: 3-27- 2018 Florida Air Service & Engineering 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone'904-823.9696 Web:WWW.NORTHFLORIDAAIR COM Project Information For: Cooling Equipment Design Conditions Outdoor design DB: 92,8°F Sensible gain: 29647 Btuh Entering coil DB: 76.8°F Outdoor design WB: 77.0°F Latent gain: 5525 Btuh Entering coil WB: 63.7°F Indoor design DB: 75,0°F Total gain: 35172 Btuh Indoor RH: 50% Estimated airflow: 1225 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC542A00300+FX4DNB049L Actual airflow: 1225 cfm Sensible capacity: 31246 Btuh 105%of load Latent capacity: 7377 Btuh 134%of load Total capacity: 38623 Btuh 110/of load SHR: 81% Heating Equipment Design Conditions Outdoor design DB: 32.5°F Heat loss: 36031 Btuh Entering coil DB: 68.5°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC542A00300+FX4DNB049L Actual airflow: 1225 cfm Output capacity: 33384 Btuh 93%of load Capacity balance: 30 °F Supplemental heat required: 2648 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1225 cfm Output capacity: 7.1 kW 67%of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. - Wtl"ghL`tip1�!- 2018-Mar-29 12:46:18 ..w_ .____ Right-Suite®Universal 2018 18.0.11 RSU09479 Page 1 ...ces\Pat Mulligan\Ahern Townhomes\1902 Right.rup Calc=MJB Front Door faces: W , a 4 g ° Project SummaryJob: Lot5AAT 1NII"1 ht5aftDate: 3-27-2018 Entire House By: Florida Air Service & Engineering 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM Pro'ect Information For: Notes: Lot 5A Ahern Townhomes Desi a n Information Weather: Jacksonville/Intnl., FL, US Winter Design Conditions Summer Design Conditions Outside db 33 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 Moisture difference 50 gr/ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 30026 Btuh Structure 24706 Btuh Ducts 6005 Btuh Ducts 4941 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 36031 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 29647 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3064 Btuh Ducts 2461 Btuh Central vent(0 cfm) 0 Btuh Area(ft2) Heating 1902 Cooling 1902 Equipment latent load 5525 Btuh Volume(ft3) 23376 23376 Air changes/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 35172 Btuh Equiv.AVF(cfm) 148 78 Req.total capacity at 0.70 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC542A00300 Cond 25HBC542A00300 AHRI ref 9155621 Coil FX4DNB049L AHRI ref 9155621 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15.5 SEER Heating input Sensible cooling 28700 Btuh Heating output 42000 Btu h @ 47°F Latent cooling 12300 Btuh Temperature rise 31 °F Total cooling 41000 Btuh Actual air flow 1225 cfm Actual air flow 1225 cfm Air flow factor 0.034 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0.25 in H2O Static pressure 0.25 in H2O Space thermostat Load sensible heat ratio 0.84 Capacity balance point=30°F Backup: Input=7 kW, Output=24267 Btuh, 100 AFUE Bold/Italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ft+' wr4yFrtsofft- 2018-Mar-2912:48:18 - Right-Suite®Universal 2018 18.0.11 RSU09479 Page 1 Aittlk ...ces\Pat Mulligan\Ahern Townhomes\1902 Right.rup Calc=MJ8 Front Door faces: W - wrightsoft• Right-J® Worksheet Job: Lot 5A AT Entire House Date: 3-27-2018 By: Florida Air Service & Engineering 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Entire House Laundry 2 Exposed wall 412.0 ft 20.0 ft 3 Room height 9.4 ft 9.0 ft heatcool 4 Room dimensions 9.0 x 11.0 ft 5 Room area 3172.0 ft' 99.0 ft' 1 I I 1 Ty ' Construction U-value Or 1 HTM Area (ft ) Load Area (ft ) Load number (Btuh/ft'-°F) (Btuh/ft') or perimeter (ft) ` (Btuh) or perimeter (ft) (Btuh) IHeat Cool Gross N/P/S I Heat I Cool Gross I N/P/S Heat I Cool 6 W 12A-Osw 0.240 n 9.00 7.25 300 300 2700 2174 0 0 0 0 ItL- 12E-Osw 0.068 n 1.84 1.03 814 806 1482 834 81 81 207 116 � 1D-clow 0,570 n 21 38 18.20 6 0 171 146 0 0 0 0 12A-Osw 0.240 a 9.00 7.25 180 150 1350 1087 0 0 0 0 11 1D-c2ow 0.570 e 21.38 52.90 30 0 641 1587 0 0 0 0 t_r_w 12E-Osw 0.068 a 1.38 0.78 633 551 763 430 0 0 0 0 �-G 1 D-c2owd 0.570 e 21.38 33.46 82 46 1744 2730 0 0 0 0 W 12E-Osw 0.068 s 2.03 1.14 1104 1104 2241 1261 0 0 0 0 Vy 12A-Osw 0.240 w 9.00 7.25 210 156 1404 1131 0 0 0 0 t- G 1 D-c2ow 0.570 w 21.38 52.90 54 0 1154 2857 0 0 0 0 12E-Osw 0.068 w 2.55 1.43 603 538 1371 771 99 95 242 136 10B-w 0.600 w 22.50 24.68 16 3 370 406 0 0 0 0 1D-c2ow 0.570 w 21.38 20.18 7 7 150 141 0 0 0 0 1D-c2ow 0.570 w 21.38 30.00 4 3 86 120 4 3 86 120 0 0 12C-Osw 0.091 - 3.41 1.39 252 233 794 324 99 99 338 138 10-c2ow 0.570 w 21.38 52.90 14 0 299 741 0 0 0 D 11 DO 0.390 w 14.62 11.78 24 24 351 283 0 0 0 I R D 11D0 0.390 n 14.62 11.78 19 19 282 227 0 0 0 0 C 18A-19xd 0.051 - 1.91 1.51 1267 1267 2423 1919 0 0 0 0 F 19C-19csco 0.049 - 0.64 0.30 700 700 446 212 0 0 0 0 F 22A-tpl 0.989 - 20.82 0.00 1267 178 3704 0 99 20 742 0 6 c)AED excursion 843 67 Envelope loss/gain 23927 20222 1614 578 12 a) Infiltration 6100 1524 349 87 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 2500 500 Subtotal(lines 6 to 13) 30026 24706 1963 1165 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 30026 24706 1963 1165 15 Duct loads 20% 20% 6005 4941 20% 20% 393 233 Aotaequomdl(cadn) I I 362251 292251 I 238601 1398 58 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrlyttaoft• 2018-Mar-29 12:46:18 +4C Rig ht-Su ite®Universal 2018 18.0.11 RSU09479 Page 1 ...ces\Pat Mulligan\Ahern Townhomes\1902 Right.rup Calc=MJ8 Front Door faces: W 4 wriglhtsoft Right-J® Worksheet Job: Lot 5A AT Entire House Date: 3-27-2018 By: Florida Air Service & Engineering 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Entry Garage 2 Exposed wall 38.0 ft 78.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft uncondit. 4 Room dimensions 1.0 x 201.0 ft 25.0 x 28.0 ft 5 Room area 201.0 ft' 700.0 ft' I I i i r r TyConstruction U-value Or HTM Area ft' Load Area ft' Load I ( ' I ( ' number (Bt t'-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) IHeat I Cool I Gross 1 N/P/S I Heat I Cool I Gross N/P/S I Heat I Cool 6 W 12A-Osw 0.240 n 9.00 7.25 0 0 0 0 0 0 0 0 \y 12E-Osw 0.068 n 1.84 1.03 54 54 138 77 225 225 0 0 �G 1D-c2ow 0.570 n 21.38 18.20 0 0 0 0 0 0 0 0 Vt12A-Osw 0.240 e 9.00 7.25 0 0 0 0 0 0 0 0 1 1 �G 1 D-c2ow 0.570 a 21.38 52.90 0 0 0 0 0 0 0 0 Vy 12E-Osw 0.068 e 1.38 0.78 0 0 0 0 252 252 0 0 t-G 1D-c2owd 0.570 e 21.38 33.46 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 s 2.03 1.14 135 135 344 194 225 225 0 0 Vy 12A-Osw 0.240 w 9.00 7.25 0 0 0 0 0 0 0 0 l-G 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 VN12E-Osw 0.068 w 2.55 1.43 153 129 329 185 0 0 0 0 106-w 0.600 w 22.50 24.68 0 0 0 0 0 0 0 0 1 D c2ow 0.570 w 21.38 20.18 0 0 0 0 0 0 0 0 1 Dc2ow 0.570 w 21.38 30.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 11 DO 0.390 w 14.62 11.78 24 24 351 283 0 0 0 0 R 12C-Osw 0.091 - 3.41 1.39 153 134 456 186 0 0 0 0 I D 1100 0.390 n 14.62 11.78 19 19 282 227 0 0 0 0 C 18A-19xd 0.051 - 1.91 1.51 10 10 19 15 0 0 0 0 F 19C-19cscp 0.049 - 0.64 0.30 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 - 20.82 0.00 201 38 1409 0 700 78 0 0 6 I c)AED excursion 131 I 0I Envelope loss/gain 3328 1036 0 0 12 a) Infiltration 664 166 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants© 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 3992 1202 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3992 1202 0 0 15 Duct loads 20% 20% 798 240 0% 0% 0 0 Airrequoo d(dm) I I I 4791 1631 1462OI I I OI OI Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ we4401h tasatt- 2018-Mar-29 12:46:18 - - Rig ht-Suitee Universal 2018 18.0.11 RSU09479 Page 2 ...ces\Pat MulliganAhern Townhomes\1902 Right.rup Calc=MJ8 Front Door faces: W 4 wrightsoftt Right-J® Worksheet Job: Lot 5A AT Entire House Date: 3-27-2018 By: Florida Air Service & Engineering 150 Hilden Road 308,Ponta Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name 2 Exposed wall 32.0 M WIC 0 ft 160 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 1.0 x 280.0 ft 4.0 x 12.0 ft 5 Room area 260.0 f t' 48.0 f N I I I I I I Ty Construction U-value Or I HTM Area (ft,) Load I Area (ft') Load number (Btuh/ft'-'F (Bt uhff0) I or perimeter (ft) (Btuh) or perimeter (ft) ( (Btuh) I Heat Cool Gross I N/P/S Heat I Cool I Gross I N/P/S Heat I Cool 6 W 12A-Osw 0.240 n 9.00 7.25 140 140 1260 1015 0 0 0 0 . V/ 12E-Osw 0.068 n 1.84 1.03 0 0 0 0 0 0 0 0 . -0 1 D-c2ow 0.570 n 21.38 18.20 0 0 0 0 0 0 0 0 12A-Osw 0.240 a 9.00 7.25 180 150 1350 1087 0 0 0 0 11 10-c2ow 0.570 e 21.38 52.90 30 0 641 1587 0 0 0 0 Vy 12E-Osw 0.068 e 1.38 0.78 0 0 0 0 120 120 306 172 �! 1D-c2owd 0.570 e 21.38 33.46 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 a 2.03 1.14 0 0 0 0 40 40 102 57 12A-Osw 0.240 w 9.00 7.25 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21,38 52.90 0 0 0 0 0 0 0 0 12E-Osw 0.068 w 2.55 1.43 0 0 0 0 0 0 0 0 106 w 0.600 w 22.50 24.68 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 20.18 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 30.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 11D0 0.390 w 14.62 11.78 0 0 0 0 0 0 0 0 R12C-Osw 0.091 - 3.41 1.39 0 0 0 0 0 0 0 0 D 11D0 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 18A-19xd 0.051 - 1.91 1.51 150 150 287 227 48 48 92 73 F 19C-19cscp 0.049 - 0.64 0.30 188 188 120 57 0 0 0 0 F 22A-tpl 0.989 - 20.82 0.00 72 9 329 0 48 16 593 0 ED 6 I Envelope loss/gain I I 3987140761 10931 -372651 12 a) Infiltration 621 155 311 78 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 4608 4692 1404 343 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4608 4692 1404 343 15 Duct loads 20% 20% 922 938 20% 20% 281 69 Total room load I I I 5529 5231 I I 16851 4; Air required(cfm) J Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ALd w11p�,res'oR 2018-Mar-2912:46:18 ittk -114- Right-Suite®U niversal 2018 18.0.11 RSU09479 Page 3 ...ces\Pat MulligantAhern Townhomes\1902 Right.rup Calc=MJ8 Front Door faces: W - wrigghtsoft- Right-J® Worksheet Job: Lot 5A AT Entire House Date: 3-27-2018 By: Florida Air Service & Engineering 150 Hilden Road 308,Ponte Vedra,R 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name M Bath 2 Exposed wall Powder 10.0 ft 5.0 ft 3 Room height 9.0 ft heat/cool 10.0 ft heat/cool 4 Room dimensions 10.0 x 12.0 ft 5.0 x 12.0 ft 5 Room area 120.0 ft' 60.0 ft' i i I I I t Ty Construction U-value Or HTM Area (ft') Load 1 Area (ft') Load number (Btuh/ft'-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross I N/P/S Heat I Cool I Gross 1 N/P/S Heat I Cool 6 W 12A-Osw 0.240 n 9.00 7.25 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 n 1.84 1.03 0 0 0 0 0 0 0 0 �G 1D-c2ow 0.570 n 21.38 18.20 0 0 0 0 0 0 0 0 12A-Osw 0.240 e 9.00 7.25 0 0 0 0 0 0 0 0 11 1D-c2ow 0.570 e 21.38 52.90 0 0 0 0 0 0 0 0 12E-Osw 0.068 e 1.38 0.78 0 0 0 0 0 0 0 0 1D-c2owd 0.570 e 21.38 33.46 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 s 2.03 1.14 90 90 230 129 50 50 128 72 V/ 12A-Osw 0.240 w 9.00 7.25 0 0 0 0 0 0 0 0 L-G 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 12E-Osw 0.068 w 2.55 1.43 0 0 0 0 0 0 0 0 108-w 0.600 w 22.50 24.68 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 20.18 0 0 0 0 0 0 0 0 1 D c2ow 0.570 w 21.38 30.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 D 11 DO 0.390 w 14,62 78 0 0 0 0 0 0 0 0 R 12C-Osw 0.091 - 3.41 1.39 0 0 0 0 0 0 0 0 D 1100 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 18A-19xd 0.051 - 1.91 1.51 48 48 92 73 0 0 0 0 F 19C-19cscp 0.049 - 0.64 0.30 100 100 64 30 50 50 32 15 F 22A-tpl 0.989 - 20.82 0.00 20 2 62 0 10 1 31 0 6 c)AED excursion -27 11 Envelope loss/gain 4471 205 1901 76 12 a) Infiltration 175 44 97 24 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 622 249 287 100 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 622 249 287 100 15 Duct loads 20%I 20% 124 50 20% 20% 57 20 Toirtalrequireroomd load(cfm) I I I 746 2921 I I 3421 12501 A Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Ala- wrtyf-rasart 2018-Mar-29 12:46:18 All- 16. Rig ht-Suite®Universal201818.0.11 RSU09479 Page 4 ...ces\Pat Mulligan\Ahern Townhomes11902 Right.rup Calc=MJ8 Front Door faces: W 4 wrightsoft Right-J® Worksheet Job: Lot 5A AT Entire House Date: 3-27-2018 By: Florida Air Service & Engineering 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name 2 Exposed wall Kitchen Dining 11.0 ft 10.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 54 Room Room area dimensions 11.0 x 14.0 ft 10,0 x 12.0 ft 154.0 ft' 120.0 fI' I I I i r Ty Construction U-value Or HTM I Area (f t') Load I Area (ft') I Load number (Btuh/ft'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) iHeat 1Cool I Gross N/P/S Heat I Cool Gross N/P/S Heat I Cool 16 W 12A-Osw 0.240 n 9.00+ 7.25 0 0 0 00 0 0 0 W 12E-Osw 0.068 n 1.84 1.03 110 110 281 158 0 0 0 0 G 1D-c2ow 0.570 n 21.38 18.20 0 0 0 0 0 0 0 0 . VI 12A-Osw 0.240 e 9.00 7.25 0 0 0 0 0 0 0 0 11 -C1D-c2ow 0.570 e 21.38 52.90 0 0 0 0 0 0 0 0 VN 12E-Osw 0.068 e 1.38 0.78 0 0 0 0 0 0 0 0 l-G 1D-c2owd 0.570 e 21.38 33.46 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 s 2.03 1.14 0 0 0 0 100 100 255 143 VJ 12A-Osw 0.240 w 9.00 7.25 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 12E-Osw 108-w 1D-c2ow 0.068 w 2.55 1.43 0 0 0 0 0 0 0 0 0,600 w 22.50 24.68 0 0 0 0 0 0 0 0 0.570 w 21.38 20.18 0 0 0 0 0 0 0 0 10-c2ow 0.570 w 21.38 30.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 D 11 DO 0.390 w 14.62 11.78 0 0 0 0 0 0 0 0 R 12C-Osw 0.091 - 3.41 1.39 0 0 0 0 0 0 0 0 D 1100 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 18A-19xd 0.051 - 1.91 1.51 11 11 21 17 0 0 0 0 F 19C-19cscp 0.049 - 0.64 0.30 154 154 98 47 100 100 64 30 F 22A-tpl 0.989 - 20.82 0.00 0 0 0 0 20 2 62 0 61 c)AED excursion Envelope loss/gain I 400 -224 -22 3 381 152 12 a) Infiltration 214 53 194 48 b) Room ventilation 0 0 0 o 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2000 0 Subtotal(lines 6 to 13) 613 2051 575 200 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 613 2051 575 200 15 Duct loads 20% 200/o 123 410 20% 20% 115 40 Total requireroomd load(cfm) I I I 7361 24106211 I 6901 2401 25 23 10 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 'i+ wrbprticsacbrt 2018-Mar-29 12:46:18 Right-Suite®Universal 2018 18.0.11 RSU09479 Page 5 ...ces\Pat Mulligan\Ahern Townhomes\1902 Right.rup Calc=MIS Front Door faces: W 4 wrightsof' Right-J® Worksheet Job: Lot 5AAT Entire House Date: 3-27-2018 By: Florida Air Service & Engineering 150 Hilden Road 308,Ponta Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Mid Stairs 2 Exposed wall Living 25.0 ft 37.0 ft 3 Room height 10.0 ft heat/cool 10.0 ft heat/cool 54 Room Room area dimensions 126 O f 1'14.0 x 9.0 ft 1.0 x 360.0 ft 360.0 ft2 i I I I I Ty Construction U-value Or I HTM Area (ft') I Load I Area (ft') Load number (Btuh/f12-°F (Btuh/ft') I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) IHeat I Cool I Gross N/P/S I Heat I Cool I Gross I N/P/S Heat I Cool I 6 W 12A-Osw 0.240 n 9.00 7.25 0 0 0 0 160 160 1440 1160 W 12E-Osw 0.068 n 1.84 1.03 20 20 51 29 0 0 0 0 �G 1D-c2ow 0.570 n 21.38 18.20 0 0 0 0 0 0 0 0 12A-0sw 0.240 e 9.00 7.25 0 0 0 0 0 0 0 0 11 1D-c2ow 0.570 e 21.38 52.90 0 0 0 0 0 0 0 0 Vy 12E-Osw 0.068 e 1.38 0.78 0 0 0 0 0 0 0 0 �f 1D-c2owd 0.570 e 21.38 33.46 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 s 2.03 1.14 140 140 357 201 0 0 0 0 12A-Osw 0.240 w 9.00 7.25 0 0 0 0 210 156 1404 1131 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 54 0 1154 2857 12E-Osw 108-w 1D-c2ow 0.068 w 2.55 1.43 90 80 204 115 0 0 0 0 0.600 w 22.50 24.68 0 0 0 0 0 0 0 0 0.570 w 21.38 20.18 0 0 0 0 0 0 0 0 1 D c2ow 0.570 w 21.38 30.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 52.90 10 0 214 529 0 0 0 0 q 1100 0.390 w 14.62 11.78 0 0 0 0 0 0 0 0 112C-Osw 0.091 - 3.41 1.39 0 0 0 0 0 0 0 0 D 11D0 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 18A-19xd 0.051 - 1.91 1.51 0 0 0 0 76 76 146 115 F 19C-19cscp 0.049 - 0.64 0.30 0 0 0 0 108 108 69 33 F 22A-tpl 0.989 - 20.82 0.00 28 6 206 0 60 6 229 0 6 c)AED excursion I 187 999 Envelope bss/gain 1032 1060 I ( 44411 62931 12 a) Infiltration 485 121 718 179 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1517 1181 5159 6473 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1517 1181 5159 6473 15 Duct loads 20% 20% 303 236 20% 20% 1032 1295 Total room load I I I 18621 1418 I I 62901 7321 Air required(cfm) Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. w�lUlItte t- 2018-Mar-2912:46:18 Right-Suite®Universal 2018 18.0.11 RSU09479 Page 6 ...ces\Pat Mulligan\Ahern Townhomes\1902 Rlght.rup Calc=MJ8 Front Door faces: W 4 wrlghttsoft Right-J® Worksheet Job: Lot 5A AT Entire House Date: 3-27-2018 By: Florida Air Service & Engineering 150 Hilden Road 308,Ponta Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Loft Mech 2 Exposed wall 37.0 ft 6.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 294.0 ft 6.0 x 3.0 ft 5 Room area 294.0 ft2 18.0 ft' I Ty Construction U-value Or HTM Area (ft2) I Load Area (ft2 Load I I I number (Bt uh/ft2-°F I (Btuh/ft2) I or perimeter (ft) I (Btuh) or ) I perimeter (ft) (Btuh) IHeat I Cool I Gross I N/P/S I Heat I Cool Gross I N/P/S I Heat I Cool 6 W 12A-Osw 0.240 n 9.00 7.25 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 n 1.84 1.03 54 54 138 77 0 0 0 0 �-G 1D-c2ow 0.570 n 21.38 18.20 0 0 0 0 0 0 0 0 12A-Osw 0.240 a 9.00 7.25 0 0 0 0 0 0 0 0 11 1D-c2ow 0.570 e 21.38 52.90 0 0 0 0 0 0 0 0 12E-Osw 0.068 e 1.38 0.78 0 0 0 0 0 0 0 0 1 D-c2owd 0.570 a 21.38 33.46 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 s 2.03 1.14 108 108 275 155 54 54 138 77 Vy 12A-Osw 0.240 w 9.00 7.25 0 0 0 0 0 0 0 0 �-L 1D-clow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 12E-Osw 0.068 w 2.55 1.43 171 151 384 216 0 0 0 0 1OB-w 0.600 w 22.50 24.68 16 3 370 406 0 0 0 0 1D-c2ow 0.570 w 21.38 20.18 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 30.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 52.90 4 0 88 212 0 0 0 0 1100 0.390 w 14.62 11.78 0 0 0 0 0 0 0 0 9 12C-Osw 0.091 - 3.41 1.39 0 0 0 0 0 0 0 0 I o 11D0 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 18A-19xd 0.051 - 1.91 1.51 294 294 562 445 18 18 34 27 F 19C-19cscp 0.049 - 0.64 0.30 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 - 20.82 0.00 9 1 42 0 0 0 0 0 I 6 I c)AED excursion I 204 -13 Envelope loss/gain 1857 171ST I 1721 921 12 a) Infiltration 646 162 105 26 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants© 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 2503 1877 277 118 Less external load 0 0 0 t 0 Less transfer 0 0 0 0 Redistribution 208 89 -277 -118 14 Subtotal 2711 1965 0 0 15 Duct toads 20% 20% 542 393 20% 20% 0 0 II Airta�uro re (cfni) I I I 32111 531 2397 I81 I 001 O Calculations aooroved by ACCA to meet all requirements of Manual J 8th Ed. -'1' wr/gtinrtsoTt- 2018-Mar-2912:46:18 _. Right-Suite®Universal 2018 18.0.11 RSU09479 Page 7 ...ces\Pat MulllgankAhern Townhomes11902 Right.rup Calc=MJ8 Front Door faces: W 1, • r 41- wrlphtsott' Right-J® Worksheet Job: Lot 5A AT Entire House Date. 3-27-2018 By: Florida Air Service & Engineering 150 Hilden Road 308,Ponta Vedra,Fl 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Bed 1 Bed 2 2 Exposed wall 33.0 ft 32.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 252.0 ft 1.0 x 240.0 ft 5 Room area 252.0 ft' 240.0 1t• I I I I I 2 Ty Construction U-value Or I HTM I Area (ft2) Load I Area (ft2) Load number (Btuh/ft2-°F (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) IHeat I Cool I Gross N/P/S I Heat I Cool ( Gross I N/P/S Heat I Cool 6 W 12A-08w 0.240 n 9.00 7.25 0 0 0 0 0 0 0 0 Vy 12E-Osw 0.068 n 1.84 1.03 0 0 0 0 162 162 413 232 �G 1 D-c2ow 0.570 n 21.38 18.20 0 0 0 0 0 0 0 0 vy 12A-Osw 0.240 e 9.00 7.25 0 0 0 0 0 0 0 0 11 1D-c2ow 0.570 a 21.38 52.90 0 0 0 0 0 0 0 0 Vy 12E-Osw 0.068 a 1.38 0.78 135 94 240 135 126 85 217 122 �G 1D-c2owd 0.570 a 21.38 33.46 41 23 872 1365 41 23 872 1365 W 12E-0sw 0.068 s 2.03 1.14 162 182 413 232 0 0 0 0 Vy 12A-Osw 0.240 w 9.00 7.25 0 0 0 0 0 0 0 0 �C 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 U12E-Osw 0.068 w 2.55 1.43 0 0 0 0 0 0 0 0 10B-w 0.600 w 22.50 24,68 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 20.18 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 30.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 0 0 0 11D0 0.390 w 14.62 11.78 0 0 0 0 0 0 0 0 9 12C-Osw 0.091 - 3.41 1.39 0 0 0 0 0 0 0 0 0 11D0 0.390 n 14.62 11.78 0 0 0 0 0 0 0 0 C 18A-19xd 0.051 - 1.91 1.51 252 252 482 382 240 240 459 364 F 19C-19csco 0.049 - 0.64 0.30 0 0 0 0 0 0 0 0 F 22A-ipl 0.989 - 20.82 0.00 0 0 0 0 0 0 0 0 6 I c)AEDEnvelopeexcursiloss/ ain n I I ( I 2221 I I I 2191 I{ 2007 1892 1961 1865 12 a) Infiltration 577 144 559 140 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 2584 2036 2521 2004 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 69 30 0 0 14 Subtotal 2653 2066 2521 2004 15 Duct loads 20% 20% 531 413 20% 20% 504 401 I Air rel qulred(cfm) I I I 31081 21021 I 30102531 2499 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. +' wriplPrit�s7rfR 2018-Mar-2912:46:18 Right-Suite®Universal 2018 18.0.11 RSU09479 Page 8 ...ces\Pat Mulligan\Ahem Townhomes\1902 Right.rup Calc=MJ8 Front Door faces: W • •. r 4 wrightsoft' Right-J® Worksheet Job: Lot 5A AT Entire House Date: 3-27-2018 By: Florida Air Service & Engineering 150 Hilden Road 308,Ponte Vedra,Fl 32081 Phone,904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM 1 Room name Bath 1 2 Exposed wall 22.0 ft 3 Room height 9.0 ft heaUcool 4 Room dimensions 12.0 x 10.0 ft 5 Room area 120.0 ft' I i I r Ty Construction U-value Or 1 HTM I Area (ft2) Load 1 Area Load number (et uh/ft2-°F) (Btuh/f12) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat 1 Cool Gross I N/P/S Heat I Cool 6 W 12A-Osw 0.240 n 9.00 7.25 0 0 0 0 VN 12E-Osw 0.068 n 1.84 1.03 108 100 255 143 C� 1D-c2ow 0.570 n 21.38 18.20 8 0 171 146 12A-Osw 0.240 e 9.00 7.25 0 0 0 0 11 10c2ow 0.570 e 21.38 52.90 0 0 0 0 Vy 2E-Osw 0.068 e 1.38 0.78 0 0 0 0 �G 1 D-c2owd 0.570 e 21.38 33.46 0 0 0 0 W 12E-Osw 0.068 s 2.03 1.14 0 0 0 0 VN 12A-Osw 0.240 w 9.00 7.25 0 0 0 0 C 1D•c2ow 0.570 w 21.38 52.90 0 0 0 0 12E-Osw 0.068 w 2.55 1.43 90 83 212 119 108-w 0.600 w 22.50 24,68 0 0 0 0 1D-c2ow 0.570 w 21.38 20.18 7 7 150 141 1D-c2ow 0.570 w 21.38 30.00 0 0 0 0 1D-c2ow 0.570 w 21.38 52.90 0 0 0 0 0 1100 0.390 w 14.62 11.78 0 0 0 0 R 12C-Osw 0.091 - 3.41 1.39 0 0 0 0 D 11 DO 0.390 n 14.62 11.78 0 0 0 0 C 18A-19xd 0.051 - 1.91 1.51 120 120 229 182 F 19C-19cscp 0.049 - 0.64 0.30 0 0 0 0 F 22A-tpl 0.989 - 20.82 0.00 0 0 0 0 6 c)AED excursion 189 • Envelope loss/gain 1017 920 12 a) Infiltration 384 96 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 1401 1016 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 1401 1016 15 Duct loads 20% 20% 280 203 Air Totalrequiroomred load(cfm) 1681 1 1219 57 50 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -4* wrbptutsort 2018-Mar-2912:46:18 .9C Right-Suite®Universal 2018 18.0.11 RSU09479 Page 9 ...ces\Pat Mulligan\Ahern Townhomes\1902 Right.rup Calc=MJ8 Front Door faces: W 1 . 1st Floor Sup Riser 10 " ILaundry A 8‘ 10 „ Garage Entry 0,, R;.,,, R,l X16" 4"14 " Job#: Lot 5A AT Florida Air Service & EngineeringScale: 1 : 75 Performed for: Page 1 150 Hilden Road 308 174ght-Suite®Universal 2018 Ponte Vedra,Fl 32081 18.0.11 RSU09479 Phone:904-823-9696 2018-Mar-29 12:46:40 WWW.NORTHFLORIDAAIR.COM ...n\Ahern Townhomes\1902 Right.rup - 2nd Floor Sup R ser 10 ' Kitchen • ` 321cf 10 " '' 233 i-ster Livi n.• 102 cfm : ' 2 " • 10„ ■ 0 4 " ►.� • 875 cfm 12 cfm 57 cfm 4 25 cfm • UI 62 cfm 6 Ling ,3 Powder M Bath M WIC Mid Stair; Su, Rise Ret Riser ■ 14' Job#: Lot 5A AT Scale: 1 : 75 Performed for: Florida Air Service & Engineering Page 2 150 Hilden Road 308 Fight-Suite®Universal 2018 Ponte Vedra,Fl 32081 18.0.11 RSU09479 Phone:904-823-9696 2018-Mar-29 12:46:40 WWW.NORTHFLORIDAAIR.COM ...n\Ahern Townhomes\1902 Right.rup '1 N 3rd Floor f Our R,.>,., qi10' Bath 1 103 cfged 2 1.11 7 cfm 111 cr6" Al 8x20 /I 8 x 20 II I Lofi 10� 1:z afro l M:.379 fm -. ser et Riser S8f .i ru 'i44 , Job#: Lot 5A AT Scale: 1 : 75 Performed for: Florida Air Service & Engineering Page 3 150 Hilden Road 308 Right-Suite®Universal 2018 Ponte Vedra,Fl 32081 18.0.11 RSU09479 Phone:904-823-9696 2018-Mar-29 12:46:40 WWW.NORTHFLORIDAAIR.COM ...n\Ahern Townhomes\1902 Right.rup A 11 0 • -Pli- wrightsoft Duct System Summary Da 3.27-Job: Lot AAs Entire House By: Florida Air Service & Engineering 150 HIlden Road 308,Ponte Vedra,FI 32081 Phone:904-823-9696 Web:WWW.NORTHFLORIDAAIR.COM Project Information For: Heating Cooling External static pressure 0.25 in H2O 0.25 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.25 in H2O 0.25 in H2O Supply/return available pressure 0.183/0.067 in H2O 0.183/0.067 in H2O Lowest friction rate 0.100 in/100ft 0.100 in/100ft Actual air flow 1225 cfm 1225 cfm Total effective length (TEL) 304 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk Bath 1 h 1681 57 50 0.100 4.0 Ox 0 VIFx 23.1 90.0 st4 Bed 1 h 3184 108 102 0.100 8.0 Ox 0 VIFx 25.9 90.0 st4 Bed 2 h 3025 103 99 0.100 8.0 Ox 0 VIFx 23.9 90.0 st4 Dining h 690 23 10 0.100 4.0 Ox 0 VIFx 35.9 150.0 st7 Entry h 4791 163 60 0.100 7.0 Ox 0 VIFx 52.4 170.0 st6 Kitchen c 2461 25 102 0.100 6.0 Ox 0 VIFx 33.2 150.0 st7 Laundry h 2356 80 58 0.100 4.0 Ox 0 VIFx 36.3 160.0 st6 Living c 7767 210 321 0.100 8.0 Ox 0 VIFx 25.3 130.0 st5 Loft h 3253 111 97 0.100 6.0 Ox 0 VIFx 21.3 90.0 st4 M Bath h 746 25 12 0.100 4.0 Ox 0 VIFx 36.7 150.0 st7 M wlc h 1685 57 17 0.100 4.0 Ox 0 VIFx 42.6 150.0 st7 Master c 5630 188 233 0.100 8.0 Ox 0 VIFx 36.6 150.0 st7 Mid Stairs h 1821 62 59 0.100 4.0 Ox 0 VIFx 26.3 130.0 st5 Powder h 345 12 5 0.100 4.0 Ox 0 VIFx 30.3 150.0 st7 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 846 875 0.100 627 16.0 0 x 0 VinIFIx st5 Peak AVF 846 875 0.100 627 16.0 0 x 0 VinIFIx st1 st6 Peak AVF 243 117 0.100 445 10.0 0 x 0 VinIFIx st5 st7 Peak AVF 331 379 0.100 694 10.0 0 x 0 VinIFIx st5 st4 Peak AVF 379 350 0.100 695 10.0 0 x 0 VinlFlx Bold/italic values have been manually overridden 4 wrghtsofl 2018-Mar-29 12:46:19 A . Right-Suite®Universal 2018 18.0.11 RSU09479 Page 1 ...ces\Pat Mulligan\Ahern Townhomes\1902 Right.rup Calc=MJ8 Front Door faces: W - *, ** Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Mat] Trunk rb5 Ox 0 846 875 81.4 0.080 819 14.0 Ox 0 VIFx rb2 Ox 0 379 350 0 0.080 695 10.0 Ox 0 VIFx Bold/Itallc values have been manually overridden 4 Wrightsr2018-Mar-2912:48:19 ._.... Right-Suite ®Universal 2018 18.0.11 RSU09479 Paget ...ces\Pat Mulligan\Ahem Townhomes\1902 Right.rup Delo=MJ8 Front Door faces: W