Loading...
1820 N SHERRY DR RESA18-0031 RESA PERMIT RESIDENTIAL ADDITION PERMIT PERMIT NUMBER 41110., Js, CITY OF ATLANTIC BEACH RESA18-0031 Ky- 800 SEMINOLE ROAD ISSUED: 12/21/2018 �� !Yr' ! � ATLANTIC BEACH. FL 32233 EXPIRES: 6/19/2019 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts,state agencies, or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: RESIDENTIAL ADDITION SINGLE 1820 N SHERRY DR OR TWO FAMILY RESIDENTIAL ADDITION AND REPAIR $121500.00 ADDITION TYPE OF REAL ESTATE BUILDING USE CONSTRUCTION: NUMBER: ZONING: GROUP: SUBDIVISION: 172020 0776 SELVA MARINA UNIT 10B COMPANY: ADDRESS: CITY: STATE: ZIP: COURSE CONTRACTING 1551 Peachtree CIR JACKSONVILLE FL 32207 LLC OWNER: ADDRESS: CITY: STATE: ZIP: YOUNG SARAH L 1820 SHERRY DR N ATLANTIC BEACH FL 32233 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS Roll off container company must be on City approved list. Container cannot be placed on City right-of-way. 1 PUBLIC WORKS EROSION CONTROL INSTALLATION INFORMATIONAL Notes: Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line(904-247 -5814)to request an Erosion and Sediment Control Inspection prior to start of construction. Issued Date: 12/21/2018 1 of 2 21" 0 10, 20. ORIGINAL FIELD WORK COMPLETED BY: TARGET SURVEYING, LLC GRAPHIC SCALE (In Feet) DATED: 04/04/2017 1 inch = 20 ft. SURVEY #286413 OPIGINhrlON DENGWIAPK DUVAL COUNTY BRASS DISK "R 688 DI -5741" N.A.V.D. 1988 ELEVATION =4.12 LOT 6 W... , LOT 3 N Q SET 112" (BEARING BASIS IRONROD (BE ) FOUND 1/2" , LB #7463 189 10'22"E 94.62' Vit,, IRON PIPE ,l 0. IN . , ,� *' 30.0 W •08 co � c�, '•`� x,�ry p`Q � A/C _ cy 7-7 34 _ _ _ ,ten,• � � L .:� a A/C 18.6' m Z11 I :.* v o w F- m _. w rz� ��S�b��C� �?�>�ry ^� z w D ON N �` zo j RETE# I8Z0 » 'o = °� :� " ]M �120'�'`SH FLOOR18.6'O A/C VATION = '14 2 N.A.V.D. T HIGHEST »»*w O . "d7LOT % 3 N.A.V.D. 7 6' �. LOT 2 v-- M 4^ C) , z , 5' UTILIn EASEM61 oC i _'I — LOT 1 FOUND 1/2" IRON PIPE L 1. LEGAL DESCRIPTION PROVIDED BY CLIENT 2. NO SEARCH OF THE PUBLIC RECORD FOR THE P 3. NO SUBSURFACE IMPROVEMENTS WERE LOCAT 4. ALL ANGLES AND DISTANCES SHOWN HEREON P 5. THE BEARINGS SHOWN HEREON ARE BASED ON C) IV I." p I. � , 32 2' ►S.. » o, 0.9' WINDOW, X°` NOOKLLI co .....� CD <, 1C/) co 5.0' 6.4' 5.0' O + O ' lb qo p'^^ ��. N N v J x � . C4X � �X' '\p• i .i to $ n' ,.`b' - 30.0' i Y x_ co S89° 10'34"W 86.93' Nom. = z FOUND 1/2" a :,. zo IRON PIPE w Q ul LOT $ .1 L- CM i (nW BLOCK CORNER POSE OF ABSTRACTING TITLE WAS PERFORMED BY THIS OFFICE AS PART OF THIS SURVEY BOTH RECORD AND MEASURED UNLESS OTHERWISE NOTED E NORTHERLY PROPERTY LINE, ASSUMED TO BEAR N89°10'22"E. ■ ■ LOCATION MAP NOTTO XWE L,ff6hL 0f5CP/P7-/0N; LOT 7, SELVA MARINA UNIT NO. 10-B, ACCORDING TO THE PLAT THEREOF RECORDED IN PLAT BOOK 36, PAGE 61, OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. FLOOD NONE: x OFFICE COPY COMMUNITY NUMBER: 120075 PANEL: 12031 CO407 SUFFIX: H t MWEVIA7-10N Off SGP/Pr/0N; LL O AIR CONDITIONER CIL a I.D. tv o Z Q CL o iv O RNV RIGHT OF WAY LL a � Lu Lu J _ac of Qui- 1. ADDED FINISH FLOOR ELEVATION ... 12-04-2018 z �W O m A/C AIR CONDITIONER CIL CENTERLINE I.D. IDENTIFICATION LB LICENSED BUSINESS N.A.V.D. NORTH AMERICAN VERTICAL DATUM P PLAT RNV RIGHT OF WAY X -k TOPOGRAPHIC ELEVATION REVISIONS: 1. ADDED FINISH FLOOR ELEVATION ... 12-04-2018 Kenneth J. Osborne PSM #6415 THIS SURVEY IS NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER Project �r.t C-16687 Date 11-02-2018 Soale 1 of 1 1"=20' U M pp M � O o �W Zi� a M 0 N O Z 20' 0 10 20' GRAPHIC SCALE (In Feet) 1 inch = ft2o SET 1/2" IRON ROD LOT 3 LB #7463 1'N uj co o � Oco ORIGINAL FIELD WORK COMPLETED BY: TARGET SURVEYING, LLC DATED: 04/04/2017 SURVEY #286413 LOT 6 OFIGINhilON D�NGtl1"'fAfK DUVAL COUNTY BRASS DISK "R 688 DL5741" N.A.V.D.1988 ELEVATION =4.12 (BEARING BASIS) FOUND v2" N09010122"E 94.62' ry IRON PIPE / +.V* l0 30.0' , ' • III ��x Stix ry� �• o '•`V x'`ry o`o II �• NOTfS; A/C '13,0' SHED ON CONCRETE 3.f F�5MNCF # 1820 WOOD 32 ' 19 moo. 00 R x o' A/C ohs 1 0 : 2 ao .. I uj 1-v LULU uj Ci o e� f Vim' '.z'• � .tn w'' -. a N t�� 'Z 12.0 18.6 • �O O a 7.6 •i Fs -1 ,.Q ' ^* cc::,) 0 ?� x , 0.9' WINDOW NOOK W Cfl f �., ti co° CC -4.4 4® 5.0' 6.4 5.0' ,�`� o C 0 1 0 I Z 0 N N v) 63 to acb o.5's S89° 10'34"W 86.93' FOUND 1/2" LOT 1 FOUND 1/2" IRON PIPE IRON PIPE LOT 8 BLOCK CORNER- 1 ORNER — O�x �O. 1. LEGAL DESCRIPTION PROVIDED BY CLIENT 2. NO SEARCH OF THE PUBLIC RECORD FOR THE PUR OSE OF ABSTRACTING TITLE WAS PERFORMED BY THIS OFFICE 3. NO SUBSURFACE IMPROVEMENTS WERE LOCATED S PART OF THIS SURVEY 4. ALL ANGLES AND DISTANCES SHOWN HEREON ARE DOTH RECORD AND MEASURED UNLESS OTHERWISE NOTED 5. THE BEARINGS SHOWN HEREON ARE BASED ON THENORTHERLY PROPERTY LINE, ASSUMED TO BEAR N89010'22"E. i LOCATION MAP narrosc LE L�6�L D�5G1Z11 �fiION,� LOT 7, SELVA MARINA UNIT NO. 10-13, ACCORDING TO THE PLAT THEREOF RECORDED IN PLAT BOOK 36, PAGE 61, OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. FLOOD ZONE: X COMMUNITY NUMBER: 120075 PANEL:12031CO407 SUFFIX: H ApoprvIIJriON PE-15MMOU A/C AIR CONDITIONER C/L CENTERLINE I.D. IDENTIFICATION Q, LICENSED BUSINESS M NORTH AMERICAN VERTICAL DATUM O O A/C RNV RIGHT OF WAY 0 1. 1 W LOT 7 LOT 2 Lu r h� ^ryti LO O Z� >\� o PAVE OLD E N I E z -_ 5' UTIL D O EASEM W � 3 z m CD NOTfS; A/C '13,0' SHED ON CONCRETE 3.f F�5MNCF # 1820 WOOD 32 ' 19 moo. 00 R x o' A/C ohs 1 0 : 2 ao .. I uj 1-v LULU uj Ci o e� f Vim' '.z'• � .tn w'' -. a N t�� 'Z 12.0 18.6 • �O O a 7.6 •i Fs -1 ,.Q ' ^* cc::,) 0 ?� x , 0.9' WINDOW NOOK W Cfl f �., ti co° CC -4.4 4® 5.0' 6.4 5.0' ,�`� o C 0 1 0 I Z 0 N N v) 63 to acb o.5's S89° 10'34"W 86.93' FOUND 1/2" LOT 1 FOUND 1/2" IRON PIPE IRON PIPE LOT 8 BLOCK CORNER- 1 ORNER — O�x �O. 1. LEGAL DESCRIPTION PROVIDED BY CLIENT 2. NO SEARCH OF THE PUBLIC RECORD FOR THE PUR OSE OF ABSTRACTING TITLE WAS PERFORMED BY THIS OFFICE 3. NO SUBSURFACE IMPROVEMENTS WERE LOCATED S PART OF THIS SURVEY 4. ALL ANGLES AND DISTANCES SHOWN HEREON ARE DOTH RECORD AND MEASURED UNLESS OTHERWISE NOTED 5. THE BEARINGS SHOWN HEREON ARE BASED ON THENORTHERLY PROPERTY LINE, ASSUMED TO BEAR N89010'22"E. i LOCATION MAP narrosc LE L�6�L D�5G1Z11 �fiION,� LOT 7, SELVA MARINA UNIT NO. 10-13, ACCORDING TO THE PLAT THEREOF RECORDED IN PLAT BOOK 36, PAGE 61, OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. FLOOD ZONE: X COMMUNITY NUMBER: 120075 PANEL:12031CO407 SUFFIX: H ApoprvIIJriON PE-15MMOU A/C AIR CONDITIONER C/L CENTERLINE I.D. IDENTIFICATION LB LICENSED BUSINESS N.A.V.D. NORTH AMERICAN VERTICAL DATUM P PLAT RNV RIGHT OF WAY X TOPOGRAPHIC ELEVATION 2 Kenneth J. Osborne PSM #6415 THIS SURVEY IS NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER u- 0 W M � O Z� CL Z'� o 2 QG 0 1. 1 W Lu E'u CA o z -_ D O W � 3 z m o o 00 Project a"a C-16687 Date 11-02-2018 Scale 1 OF 1 1"=20' 0 0 � W M � aU 'Inn o W � 3 z I� _ w o o 00 a w v'� a 5� s N 0 wX0 z M z w Mn Ow ~ J 0Z 0 — Z06 ;�r, w z0 U) w X w 6-0" EXISTING :2 NOTES SCALE DRAWINGS. USE ONLY DIMENSIONS SHOWN ON 'S. IF DIMENSIONS ARE IN QUESTION, THE BUILDER RESPONSIBLE FOR OBTAINING CLARIFICATION CONTINUING WITH CONSTRUCTION. BUILDER SHALL kLL DIMEN IONS & CONDITIONS AT JOBSITE. DNS SHOW ARE TO FACE OF FRAMING OR -INE OF ST RUCURE UNLESS OTHERWISE NOTED. DOORS SO THAT DOOR CASING ABUTS WALL FINISH OF qT WALL U LESS OTHERWISE NOTED. SHALL CO RDINATE ALL SHELVING & STORAGE _MENTS WI -H DESIGNER OR OWNER. VENT OF Af JY DISCREPANCIES, IMMEDIATELY NOTIFY SER. DON T PROCEED WITH AFFECTED WORK UNTIL H ISSUES HAVE BEEN FULLY RESOLVED. STRUCTIO SHALL BE PERFORMED IN ACCORDANCE L CODES, R GULATIONS, AND RESTRICTIONS HAVING TION. ELECTRICAL LEGEND Tv CABLE 3' DUPLEX OUTLET C7 220 OUTLET @ QUADRAPLEX OUTLET @ GFI GFI RECEPTACLE 6 EXTERIOR/GFI RECEPTACLE LL SWITCH 3 3 -WAY SWITCH SD SMOKE DETECTOR CM CARBON MONOXIDE DETECTOR CH COUNTERTOP HEIGHT NOTES: 1. TELEPHONE OUTLETS TO BE'CAT 5E' WIRE. 2. SMOKE DETECTION PER FIRE CODE. 3. SERVICE PANEL AND ELECTRIC METER LOCATION TO BE DETERMINED W/ INPUT FROM THE OWNER AND LOCAL UTILITY COMPANY. 4. ALL RECEPTACLE TO HAVE ARC -FAULT CIRCUIT INTERRUPTERS PER ARTICLE 210-12. 5. HVAC DISCONNECT TO BE PROVIDED BY MECHANICAL SUBCONTRACTOR. 6. ALL ELECTRICAL WIRING TO BE IN ACCORDANCE WITH LATEST EDITION OF NEC AND FBC. 7. 100% OF ALL INTERIOR AND EXTERIOR PERMANENT LIGHT FIXTURES TO USE CFL/LED LAMPS. C)f II 19'-9" 13-10" LO PROJECT ADDRESS - ------ DRAWING INDEX 3' 6" T-0" -- -or ;'0 -T 6' C7 OUTDOOR ;`A lk 1 z LIVING AREA MI RO MIXEI � 4" STE LL VAULTED T&G CEILING _ I -� 0 10 I PROVIDE SKYLIGHTS PER OWf IER CODE ENFORCEMENT JURISDICTION: CITY OF ATLANTIC BEACH z 0 SELECTIONS & LOCATIONS ,8-- ��t r 4F ZI SPRINKLED: NO FIRE DISTRICT: NO 14 I---- co ------ - �� 18 C( OPEII C-tG-V*-SKYLtG-ITS � Q -1 U w_ YO O B o , �z A2 O � D 1 O (D 1 0 17'-7" ALIGN W/ EXISTING 7'-2" F 5'-0" OVERHANG lo 00 Zp�o �0Qo� � w �'w2 W UU=cp O w p N ''' U)0 Uj azl I 4'-0" II 3/0 CH GFI \FW REF \ -1 1 11' 6" \ 0 LI "X45.75" 130"X45.75" — — KITCHEN — KYGHT SKYLIGHT - J _ J 10' CEILING 2'-8"x5' DH 2'-8"x5' DH OVEN NEW DESIGN wlNDow FIREPLACE WINDOW BY OTHERS REMOVE EXISTING WIND NEW CASED!OPENINC FIRST FL SCA -E: 1/4" = T-0" it OOR PLAN FAM I LY EXISTING YOUNG RESIDENCE RENOVATION PROJECT ADDRESS - ------ DRAWING INDEX 3' 6" T-0" -- -or ;'0 -T 6' C7 A2 EXTERIOR ELEVATIONS AND DETAILS WORK AREA - � - -- - z �' MI RO MIXEI � 4" STE NEW A/C: 322 SQ. FT. CEILING HEIGHT -wo I -� 0 10 I 0 BUILDING CODE SUMMARY CODE ENFORCEMENT JURISDICTION: CITY OF ATLANTIC BEACH z I- C AN "IFIION: RESIDENTIAL (R-3) ��t r 4F a- 0 O SPRINKLED: NO FIRE DISTRICT: NO 14 w �� 18 C( OPEII C-tG-V*-SKYLtG-ITS 0 LI "X45.75" 130"X45.75" — — KITCHEN — KYGHT SKYLIGHT - J _ J 10' CEILING 2'-8"x5' DH 2'-8"x5' DH OVEN NEW DESIGN wlNDow FIREPLACE WINDOW BY OTHERS REMOVE EXISTING WIND NEW CASED!OPENINC FIRST FL SCA -E: 1/4" = T-0" it OOR PLAN FAM I LY EXISTING YOUNG RESIDENCE RENOVATION PROJECT ADDRESS - ------ DRAWING INDEX 1820 SHERRY DRIVE N. Al RENOVATION PLANS ATLANTIC BEACH, FL 32233 A2 EXTERIOR ELEVATIONS AND DETAILS WORK AREA - EXISTING FIRST FLOOR A/C: 1,480 SQ. FT. REMOVED AND EXISTING SECOND FLOOR A/C: 1,315 SQ. FT. 4" STE NEW A/C: 322 SQ. FT. CEILING HEIGHT NEW TOTAL A/C: 3,117 SQ. FT. NEW A/C VOLUME: 3,222 CU. FT. I 0 BUILDING CODE SUMMARY CODE ENFORCEMENT JURISDICTION: CITY OF ATLANTIC BEACH WIND ZONE: 130 MPH (WIND-BORNE DEBRIS) FLORIDA BUILDING CODE 2017 - 6TH EDITION C AN "IFIION: RESIDENTIAL (R-3) ALTERATION LEVEL: 2 N ION TYPE: TYPE V -B (WOOD FRAME ADDITION) SPRINKLED: NO FIRE DISTRICT: NO LIVING EXISTING 8' CLG -0" EXISTING 10' * 0 ROOM c� o z TRAY CLG TO BE Q w REMOVED AND 4" STE a CEILING HEIGHT e n. 0 o U) w TO BE INCREASE i U) TO MAX POSSIBLE w U Q Ow �z W CD Of L Q 2/6 O z Q A A2 LAUNDRY REMOVE EXISTINGE, KITCHEN CABINETRY, FIXTURES, APPLIANCES O- ---------------- I DI MUD ROOM — — — t3UILl-1N5 EXISTING ELECTRICAL TO REMAIN O 0 z Q r — —tit — — w O ` z MA;TER w 8' CLG ALIGN W/ EXISTING z w c� I-- 2/6 Q 4" STE e n. 0 o LAUNDRY REMOVE EXISTINGE, KITCHEN CABINETRY, FIXTURES, APPLIANCES O- ---------------- I DI MUD ROOM — — — t3UILl-1N5 EXISTING ELECTRICAL TO REMAIN O 0 z Q r — —tit — — w O ` z MA;TER w 8' CLG ALIGN W/ EXISTING 3-0" 5'-6" EXITTIN 2/6_ J!2/4J WALK-IN LIN IN . 1 O w CLO ET - o I MASTER 2/0 z I BATH I � 8' CLG ,lo Q0 -- I NEW x34" „ �7� FRE TANDINCLSET 6 10 NEW VANITY ATH�UBz6'10" CLGO v I-------- ���0 H v I GARAGE EXISTING RELOCATE HVAC UNIT �? C A2 JuhanneN. Overby, RA Architectural and Interior Design Julianne N. Overby, R.A. 2452 Pullian Street Jacksonville Beach, Florida 32250 904-704-8628 Email: jnoverby@att.net FL. AR -0017060 • FL. ID -4621 LIJ 0 M z zN N W W M J Q � � U wRQ I..L W ry W m W CSO. O Z rT i ,z ni OUzl �0--p= . A Q 6 4 6► .�' �.+� r` 1 U J c cry O w r < REVISION 4J1 >^. i rl BP# ��� O018 ~ ` r DATE^/ 1, / SIGNED La A,11-2-18 REVISIONS PER CITY COMMENTS DATE ISSUED: OCTOBER 19, 2018 NOTE: DO NOT SCALE DRAWINGS. IF PRINTED ON 11 "X17" MEDIA, DRAWING SCALE IS HALF -SIZED. RENOVATION PLANS 2013 O� Al 1OVERBYi �r PERMIT SET ��STER I U) CLOSET,�I ( 8' CLG 0 O z 2 OzW a i Q 0W0 Z Z Z I — 3-0" 5'-6" EXITTIN 2/6_ J!2/4J WALK-IN LIN IN . 1 O w CLO ET - o I MASTER 2/0 z I BATH I � 8' CLG ,lo Q0 -- I NEW x34" „ �7� FRE TANDINCLSET 6 10 NEW VANITY ATH�UBz6'10" CLGO v I-------- ���0 H v I GARAGE EXISTING RELOCATE HVAC UNIT �? C A2 JuhanneN. Overby, RA Architectural and Interior Design Julianne N. Overby, R.A. 2452 Pullian Street Jacksonville Beach, Florida 32250 904-704-8628 Email: jnoverby@att.net FL. AR -0017060 • FL. ID -4621 LIJ 0 M z zN N W W M J Q � � U wRQ I..L W ry W m W CSO. O Z rT i ,z ni OUzl �0--p= . A Q 6 4 6► .�' �.+� r` 1 U J c cry O w r < REVISION 4J1 >^. i rl BP# ��� O018 ~ ` r DATE^/ 1, / SIGNED La A,11-2-18 REVISIONS PER CITY COMMENTS DATE ISSUED: OCTOBER 19, 2018 NOTE: DO NOT SCALE DRAWINGS. IF PRINTED ON 11 "X17" MEDIA, DRAWING SCALE IS HALF -SIZED. RENOVATION PLANS 2013 O� Al 1OVERBYi �r PERMIT SET ��STER U100D FRAi-E CONSTRUCTION CODE CO^^'IPL�I/N. T UNDO- INSTA__=.TION METILOD CFB R�03.o @ _ WEGTHER t'`-SITIVE PARR'.R <WRB1 APPLIED PRIOR TO THE [LINC;O,I INSTALL4TION. FL -5-111;•s APPLI=D QyE@ -f-E FACE OF THE f'OINTf� F1 141"E. STEMS SEO.T.';ON..A I liN WATER S'-VEDD FA4HIOh 'VIROJGH J.INDQU JAMB �TARTIVG 4- THE 3lR= 6 '.8 WALL . IArctl`li TOi'A40S 'HE tCa. MBTALL THE THE DF 5EA A4T BEAD ; (f.A—Y SLL F-ASHIHG'ia6"1 FLFJK'sE.--\ / j) —Y BEAD A BACK _AlICa O EAD . DOTH A SEAL 'EHE WM FRNVE "IO OP It. `y_y„a- D.ryryT1T!yyg19 __ TO p ?6' µ}- "I O rHE BAC55 DE 90TTOM ANG4vinG I1 M [RIOR1 GF THE DGU EL?I.-t. M L 1_ r--C� V gA.."HED FOL -s OR 9LO 5 ,\ ZU se -w xwus Li Il = FLAsuING—� .acREuS TO FACILITATE QJAHE FLASHING SEALe4t BEAD eETLE �: (?) A�F4.Y JArB q.ASHiw II FLAeHMG NID HO.MTIFki FLAIL'.=_. HE ONE. S l H_ '-'A' NG ArG.S AT p=RY BEAD OF EEA , I THE 10P HEAD) H 91 - /JAMBe CF Wh.DdL. �\ E'le� 'AVB FLASHRG `!TO SEAL AI.D ASTEN �. (� A=BLY HEAD F_A -T- g RE`rOR �NOJ^AY APPLIED /. TAPE. AL' WM LLRB TO -LAY FLAT .2. FLASFI APPLY IOW SHE OUT - TA O.£R IAGdJA AT HEAD 51 FLASHING AT HE D EYT_ND3 I'. i I 154EAD_-LAeF NG �� Asa. RE'/Ia.sLT I A Y '' APDL E'�3EALAN FL. SFMG AES i�l I. qj Y - a+E�sE.:E e� HEm BEY AI , 'S1JAM3 FLASHIVC2 ' EZTEND : FLAEHMG t0 % _. ___ CF JAMB E - HEAL. D F HE UNDER FLAP 5EALAN GF LRD AT TF6EE RAY., � (� �I ,�, � ` 9t' .L. SHhG 1 S - ND ApAL4''1"NDpJT E 50,1 J`IeaA4D LE.2_ CONDiT CtJ US CORRO 104 •`j`R rz=•'AVFlL111RER S�ECIFICAtI0N6 P_R I 1 COt EATHE[R RE5s5TAt\T. A' A 49 DEGREE A1JCiE, CAZNLLY CUT THE \ �9ARR -R GN A pIK+DV -NT:Y Ra BE THE ',,, I TOP EDC= 6 -HE 3. RRI '? AND APE THE � roP cc¢�� Ary cera -R ro n. TEwaz I. LRa wFSACE ADO`r. INTER'OR VIE'J T1-- LE CORNER C= W'NGOL _. l 1� � NOTES: pl to 1. flashN to be flepble self-adhesive type (min. 4" wide) $ill pan flashing •\ 2. coversill to at least depth of window, plus 2' onto face of wrt —siopetl surface ( optional) 3. the pan shall direct water to the exterior over sill flashing sill plate 4. install flashing around remaining window unit @ 5. weather resistive barrier to form water shedding laps see note p2 � SILL PAN FLASHING weather resistive barrier NTS (optional) wall sheathing ----', P-eparea by 504F First Coast Chapter 9-11-2013 NOTE: THIS DETAIL USED FOR DOORS & WINDOW. ALL FLASHING TO MEET FBC R903.2.1, R905.2.8. & R703.8 AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. ASPHALT SHINGLE — ROOF ON 15# ROOFING TO MATCH EXISTING FELT OVER 7/16" EXT. SHEATHING METAL HURRICANE CLIP AS REQUIRED BY CODE— SEE STRUCTURAL 12 6 MATCH EXISTING METAL DRIP OVER VINYL FASCIA OVER 2X6 SUB FASCIA TO MATCH EXISTING VARIES MATCH EXISTING OVERHANG 2X4 EXTERIOR WALL'— W/ z" OSB SHEATHING WRAPPED IN WATERPROOFING MEMBRANE INSTALL HARDIPLANK LAP SIDING PER MANUFACTURER'S RECOMMENDATIONS R-38 INSULATION 1/2" GYP. BOARD —13 INSULATION SLOPE e — g = FE� F3 i F= i F] I=I __� 111- III - III — A .1 I-� 2"x4" BOTTOM PLATE NEW ROOF LINE TO MATCH EXISTING CLG. = 8'-0" _ - T02 _- �- o -- ci m f= EXTERIOR FINISH— TO MATCH G7 EXISTING S - — F.F. U-0" _ - - STEM WALL PAINTED I NEW CLOSET ADDITION TO ALIGN W/ EXISTING I A REAR ELEVATION A2 SCALE: 1/4" = V-0" NEW ROOF LINE TO MATCH EX STING — 4" CONCRETE SLAB OVER CY, M VAPOR BARRIER ~ N N SEE STRUCTURAL DRAWING O M z J EXTERIOR FINISH TO MATCH E ISTING w LL —1/2" EXP. JOINT v 2 —GROUT FILLED 8" CMU q STEMWALL 00 — CONT. CONCRETE FOOTING m SEE STRUCTURAL DRAWINGS — U ADDITION WALL SECTION SCALE=:3/4" = T-0" NEW CLOSET ADDITION TO ALIGN W/ EXISTING DcSIDE ELEVATIONSCALE: 1/4" = T-0" F.F. _ -411 fx V V 1— r - SCALE: 1/8" = T-0" ACCENT STONEA .r I� CHIMNEY STACK NEW ROOF LINE TO BE OVER -FRAMED & MATCH EXISTING -0" OVER \ EXTERIOR FINISH \ TO MATCH \ EXISTING n _ F.F. 0t-0 STEM WALL PAINTED TO MATCH NEW KITCHEN ADDITION TO ALIGN W/ EXISTING EW ROOF LINE TO MATCH EXISTING 20'-0" NEW OUTDOOR LIVING AREA ADDITION - VAULTED CEILING ACCENT STONE CHIMNEY STACK - - -` - 12 - CONFIRM 6 EXISTING EXISTING TO REMAIN LLJ �— �� -T VAULTED T&G CEILING Alf OUTDOOR LIVING A EA CLG. =101-011 F.F. = -4" NECLG. = 10'-0" EXISWTI = 8'-0" Julianne N. Overby,RA Architectural and Interior Design Julianne N. Overby, R.A. 2452 Pullian Street Jacksonville Beach, Florida 32250 904-704-8628 Email: jnoverby@att.net FL. AR -0017060 • FL. ID -4621 W U CY, M z Z N N L W M J Q � LL 2 LLI ryW EY W m Ur 2 U z p Z : D (N 00J 0 a DATE ISSUED: OCTOBER 19, 2018 NOTE: DO NOT SCALE DRAWINGS. IF PRINTED ON 11"X1711 MEDIA, DRAWING SCALE IS HALF -SIZED. EXTERIOR ELEVATIONS AND _t :r DETAILS ISTING TO REMAIN EXTERIOR FINISH MOVE EXIS ING TO MATCH �I ENCH DO S EXISTING RUCTURA O PR IDE HEAD FOR NE 12' SLIDER OOR10 "2 ��18 0 - STEM WALL PAINTED TO MATCH RB , ,~?t M. ..,k,FL Q NEW ADDITION TO ALIGN W/ EXISTING/ \W SIDE ELEVATION , 13 PERMIT SET SCALE: 1/4" = V-0" ON GARAGE FRONT ELEVATION SCALE: 1/4'' = 1'-J" -------- m GARAGE FLOOR 71')_ SCALE: 1/4'' = 1'-0" PLAN B A3 Y1 K`B� GARAGE SIDE ELEVATION SCALE: 1/4" = 1'-0" U LL S X G Julianne N. Overby, RA Architectural and Interior Design Julianne N. Overby, R.A. 2452 Pullian Street Jacksonville Beach, Florida 32250 904-704-8628 Email: jnoverbv@att.net FL. AR -0017060 • FL. ID -4621 W C)(Y) (Y) Z ZN N W W M J QFro L.L DU) W C)= w wm (D = U Z U) �= c) z : D00J C\1 O�a DATE ISSUED: OCTOBER 19, 2018 NOTE: DO NOT SCALE DRAWINGS. IF PRINTED ON 11 "X17" MEDIA, DRAWING SCALE IS HALF -SIZED. r C7, COP cif DETACHED GARAGE PLAN AND ELEVATIONS rc_'� GARAGE REAR ELEVATION o�' B A3 SCALE:1/4" = 1'-0'' �• 410, dp FG I STE A3 PERMIT SET GENERAL DEMOLITION NOTES: 1. ALL DEMOLITION WORK TO BE PERFORMED UNDER G.C. CONTRACT. G.C. TO FIELD VERIFY ALL EXISTING CONDITIONS. 2. SURVEY EXISTING CONDITIONS OF THE BUILDING TO DETERMINE IF REMOVING ANY ELEMENT MIGHT RESULT IN STRUCTURAL DEFICIENCY TO ANY PORTION OF THE STRUCTURE OR ADJACENT STRUCTURES. NOTIFY THE ARCHITECT AND STRUCTURAL ENGINEER IN WRITING PRIOR TO COMMENCING ANY ADDITIONAL WORK FOR DIRECTION IF DEFICIENCIES ARE NOTED. 3. TURN OFF NECESSARY POWER AND UTILITIES PRIOR TO COMMENCING ANY DEMOLITION WORK. 4. ITEMS INDICATED TO BE REMOVED SHALL BE REMOVED AND LEGALLY DISPOSED OF IN ACCORDANCE WITH APPLICABLE CODES. 5. PROTECT EXISTING ITEMS TO REMAIN. THESE ITEMS TO BE COORDINATED WITH THE OWNER PRIOR TO ANY DEMO WORK. 6. DEMO AND REMOVE EXISTING INTERIOR DOOR / DOOR FRAME / DOOR SILL /CASING UNLESS OTHERWISE NOTED (U.O.N) ON PLAN. 7. CUT OPENINGS NEATLY AND HOLES PLUMB, SQUARE AND TRUE TO DIMENSIONS REQUIRED. USE CUTTING METHODS LEAST LIKELY TO DAMAGE CONSTRUCTION TO REMAINING OR ADJOINING CONSTRUCTION. 8. ANY FIRE EXTINGUISHERS TO BE REMOVED AND STORED FOR FUTURE USE. 9. AUTHORIZED CONSTRUCTION PERSONNEL ONLY WITHIN THE CONSTRUCTION AREA. 10. WORK TO BE DONE IN SUCH A MANNER AS TO HAVE MINIMUM DISRUPTION TO ONGOING CITY BUSINESS AND PARKING LOT. 11. CODES AND REGULATIONS: COMPLY WITH GOVERNING CODES AND REGULATIONS. 12. USE EXPERIENCED WORKERS. 13. OCCUPANCY: IMMEDIATE AREAS OF WORK MAY BE OCCUPIED DURING DEMOLITION BY THE HOME OWNERS. 14. DEMOI-ISH DESIGNATED IMPROVEMENTS AS NECESSARY TO IMPLEM1 NT RENOVATION PLAN. 15. IMPLEMENT POLLUTION CONTROL DURING BUILDING DEMOLITION. 16. HAZARDOUS MATERIALS: IF HAZARDOUS MATERIALS ARE NOTED THEY WILL BE REMOVED UNDER SEPARATE CONTRACT. NOTIFY OWNER IF HAZARDOUS MATERIAL IS DISCOVERED TO BE PRESENT. 17. DO NOT DAMAGE BUILDING ELEMENTS AND IMPROVEMENTS INDICATED TO REMAIN. ITEMS OF SALVAGE VALUE, NOT SPECIFIED ITEMS TO BE RETURNED TO OWNER, SHALL BE REMOVED FROM STRUCTURE. STORAGE OR SALE OF ITEMS IS PROHIBITED. 18. UTILITIES: LOCATE, IDENTIFY, DISCONNECT, AND SEAL OR CAP OFF UTILITIES IN AREAS TO BE DEMOLISHED. 19. SHORING AND BRACING: PROVIDE AND MAINTAIN INTERIOR AND EXTERIOR SHORING AND BRACING AS REQUIRED. 20. OCCUPIED SPACES: DO NOT CLOSE OR OBSTRUCT STREETS, WALKS, DRIVES, PARKING SPACES OR OTHER OCCUPIED OR USED SPACES OR FACILITIES WITHOUT THE WRITTEN PERMISSION OF THE OWNER AND THE AUTHORITIES HAVING JURISDICTION. DO NOT INTERRUPT UTILITIES SERVING OCCUPIED OR USED FACILITIES WITHOUT THE WRITTEN PERMISSION OF THE OWNER AND AUTHORITIES HAVING JURISDICTION. IF NECESSARY, PROVIDE TEMPORARY UTILITIES. 21. RESTORATION- RESTORE FINISHES OF PATCHED AREAS. DEMOLITION KEY NOTES 1. REMOVE ALL WALL PARTITIONS INDICATED BY DASHED LINES, INCLUDING ALL GLAZING AND TRIM. 2. REMOVE ALL MILLWORK, INCLUDING ALL PLUMBING FIXTURES & APPLIANCES INDICATED BY DASHED LINES. 3. REMOVE ALL EXISTING FLOORING AND WALL FINISHES SHOWN FOR DEMOLITION ON THESE DRAWINGS. PATCH UNEVEN SURFACES AND PREPARE FOR NEW FINISHES. 4. REMOVE EXISTING DOOR/WINDOW AND FRAME. PREPARE FOR NEW WALL AND/OR OPENING AS SHOWN IN NEW PLAN. 1 � 1 BEDROOM j -j CLOSET EXISTING EXISTING REMOVE & INFILL EXISTING DOOR rt1 I OFFICE \\ ^ I \\ EXISTING 00 \ 0 1 z Q J w z II II PLAYROOM ® G EXISTINO II O STORAGE EXISTING BEDROOM EXISTING 0 BEDROOM EXISTING SECOND FLO )R DEMOLITION PLAN SCALE: 114" = T-0" I z . II :D 0 1 � to II LL II z 4 0 LU II z O N N LIVING ROOM EXISTING 8' CLG MASTER BATH N EXISTING EXISTING 1QT 4" STEP KITCHEN / // EXISTING PREVIOUS EXTERIOR Lj- WALLS TO BE RE/M/OVED REMOVE STRUCTURAL Ew(;C NEER TO & INFILL REDESIGN W/ BEAUS TO ALLOW FOR EXISTING DOOR \ 8' CEILING HE16 T TO CONTINUE I — �I ADDITION 4" SLAB TO BE REMOVED w z 240 � REMOVE L� FINISHED FLOOR TO ALIGN WITH U) E�XISTI G 1 EXISTING LIVING ROOM FINISHED HiQ SHOWS0 FLOOR w Flo PREPARE I LIMIT OF SLAB DEMO z FOR NEW EXISTING NEW 4" STEP LOCATION TOILET TO REMAIN MASTER BATH ) Q @ EXISTING <<� MASTERCLOSET� / REMOVE DINING KITCHEN I EXISTING EXISTING VANITY zzN ROOM N REMOVE ALL I 1 3 CO RE FOR NEW PREPARE REMOVE EXISTING TRAY GLG TO BE CABINETRY, o TUB REMOVED AND >- 0 r- APPLIANCES & )1 (l �) PREPARE CEILING HEIGHT m PLUMBING 2co U zq FOR NEW TO BE INCREASE FIXTURES TO BE Z : D� (N FO MAX POSSIBLE O RELOCATED IN FAM I LY ROOM EXISTING FIRST FLOOR DEMOLITION- PLAN_ SCALE: 1/1" = 1'-0" NEW KITCHEN LOCATION i L01 GARAGE EXISTING �gR'PA 0." NERB Y , oz Vy Julianne No Overby, RA Architectural and Interior Design Julianne N. Overby, R.A. 2452 Pullian Street Jacksonville Beach, Florida 32250 904-704-8628 Email: jnoverby@att.net FL. AR -0017060 - FL. ID -4621 W U M M zzN N W W CO � J U) o Z W >- 0 r- 0 W 0,0 W m Ur 2co U zq Z : D� (N J O � Q DATE ISSUED: OCTOBER 19, 2018 NOTE: DO NOT SCALE DRAWINGS. IF PRINTED ON 11 "X17" MEDIA, DRAWING SCALE IS HALF -SIZED. DEMOLITION PLANS 7E. C E 11 V -1E?[,%)?, PERMIT SET U W 04 W 0 W LU > Z 3 O V) O Z tl J Z O Z 0 Z W Z LU > w V) V) Z a 0 LU J V) O z 0 J Z W LU Z Z UJ Z Q Ce Z W Z 0 Z LU CL 0 Q �w ON 00 �Q OZ >- O Z Q Z Z � 0 0-0 04�Q O< J Z O O N Z zLU LUJ U< °W LU w> 0 0Q oW wU fYi J 0= V) JW QO NU �Q w� U Z0 OU Udi 9� N X UJO o0- ¢a J 0 Eve LU F Z 0 LU rW Q�a �Z Z O z LU U� J Ll: J U" .Z ZZ �U_ W LL W zJ: (D:r Z 3 Zv Q� ao o� LOT 3 SET 1/2" IRON ROD LB #7463 00 W 00 C:> 0.1'N NEW SHED BASIS(B)ARING s•• I FOUND 1/2" IRON PIPE°10' 211E 94.82,, N89's 9025.0 �• �� p� �J •• `� '' 1 ,. 30.0 . 1 :V tN1 �� Vc / ) , It1 CU V .01 SHED ON cfi CONCRETE STORM ER OVERFLOW DISCHARGE PIPE Q� SCO CY ERV'�1R 1 I Q c61 II A/C 18.6No- - 0 o :, Z H' 34.1 �, �. W Q act s.s• p�5',G�NCE # 1820 ...111 LOT 7 LOT 1 4 W UJ a: A. 1 " d ' C� z ''" .•ti 12.0 c,,'` . ••<' : Y• I Cy : p Ir .. 1 EA 8.6'',46 ' A.m 0 • CL I 14 err 7.6' 1110 ; . r-W..' `' 1 W46 -94 r, VOW44viu, 901 �0,4911 1 1, 0.9' WINDOW I NOOK LUICr. 00r L, Ir-a Cb, At Cb. PAVER 5.0' -5.0' 4! � o F fa6.41 h �' - - ^� VI -1 o ` : w •• IN 05 �In IXLaiC4 i1 FUTILITY OVERFLOW DISCHA GE PI ° 2 W 23,0 +. EASEMENT C ' •M. EASE ' ' +a� M - ,Cb` 12.0 a oto �--- 1 -�- 30.0 _J • _ i•.. At At 1 _ 03 • 03S o 1 411W 86.93 '�� .;.. = Z S89 10 3 • .: FOUND 1/ 00 FOUND 1/2" IRON PIPE : -:a z UJ IRON PIPE "' 't ' CO LLJ OT 8 �: F M : }i I W BLOCK r CORNER LEGEND X99 PRE -DEV. SPOT EL. 9' POST -DEV. GRADES - SF- SILT FENCE POST -DEV. FLOW PTH. 1. CONTRACTOR SHALL INSTALL AND MAINTAIN SILT FENCE AS SHOWN IN DETAIL PROVIDED. 2. CONTRACTOR SHALL INSTALL GUTTERS FOR ROOF RUNOFF COLLECTION. GUTTERS SHALL BE CONNECTED TO STORMWATER RESERVOIR. DRAINAGE EROSION CONTROL PLAN SCALE: 1 " = 10' Fater FC City of Atlantic Beach -Drainage Calculations Drainage Criterid Section 24-66 of the City of Atlantic Beach's Zoning, $ubdivision, and Land Development Regulations requires that the difference between pre and postdevelepment volume of stormwater runoff be stored on site. Volume of Runoff is defined as V = CAR/12 V =Volume of Runoff C = Coefficent of Runoff (C--0.6150% max imperviousness), C=0.4(259 max irnipecviousness, C=O.2(0% imperviousness)) A. = Area of Lot (SQ -FT) R = 25yr/24hr rainfall depth (9-3 inches for Atlantic Beach) Predevelo ernent Run+of Volume Lot Area (A) 9074 sqft Rational Runoff Coefficent C ,,� c "Cl, Weighted' Type Area s ft Cat Area s Impervious- 2552 9074 1 0.28 Previous SFR Pervious 652.2 9074 4.2 0.14 Runoff Coefficient C" = 0.42 Rainfall Depth R 9.3 inches Predevelopement Volume(V) 2989 cubit ft Post Development Runoff Volume Lot Area (A� 9074 sq ft Rational Runoff Coefficent C Weighted Type Area (s�gft) Lot Area(sgft) "C" Impervious _ 3601 9074 1 0.40 %imp. Pervious 5473 9074, 0-2 0.12 Runoff Coefficient C = 0.52 Rainfall Depth it 9.3 inctles. Predevelopernent Volume (V) 3639 cubic ft 40% Postdevelopment Runoff Volume Predeveloment Runoff Volume Required Storage Volume Elevation SITE AREA TABULATIONS EXIST LOT AREA: 9,074 S.F. NEW ADDITION: 782 SF 13 Together 82 S.F. NEW SHED: 18 1 S.F. TOTAL NEW: 1,049 SF EXIST. SFR:20 SOO cubic feet 7 S.F. EXIST. PAVEMENTS: 50 S.F. TOTAL EXIST.: 2,552 S.F. TOTAL NEW IMP. 39 01 S.F. (39.7%) DRAINAGE EROSION CONTROL PLAN SCALE: 1 " = 10' Fater FC City of Atlantic Beach -Drainage Calculations Drainage Criterid Section 24-66 of the City of Atlantic Beach's Zoning, $ubdivision, and Land Development Regulations requires that the difference between pre and postdevelepment volume of stormwater runoff be stored on site. Volume of Runoff is defined as V = CAR/12 V =Volume of Runoff C = Coefficent of Runoff (C--0.6150% max imperviousness), C=0.4(259 max irnipecviousness, C=O.2(0% imperviousness)) A. = Area of Lot (SQ -FT) R = 25yr/24hr rainfall depth (9-3 inches for Atlantic Beach) Predevelo ernent Run+of Volume Lot Area (A) 9074 sqft Rational Runoff Coefficent C ,,� c "Cl, Weighted' Type Area s ft Cat Area s Impervious- 2552 9074 1 0.28 Previous SFR Pervious 652.2 9074 4.2 0.14 Runoff Coefficient C" = 0.42 Rainfall Depth R 9.3 inches Predevelopement Volume(V) 2989 cubit ft Post Development Runoff Volume Lot Area (A� 9074 sq ft Rational Runoff Coefficent C Weighted Type Area (s�gft) Lot Area(sgft) "C" Impervious _ 3601 9074 1 0.40 %imp. Pervious 5473 9074, 0-2 0.12 Runoff Coefficient C = 0.52 Rainfall Depth it 9.3 inctles. Predevelopernent Volume (V) 3639 cubic ft 40% Postdevelopment Runoff Volume Predeveloment Runoff Volume Required Storage Volume Elevation Length Width 13 4 13.x+ S Reserve€or 2 Posts Elevation Leith Width 13 Together 13-5 » IngroLlnd Strotage Before Installation Area 476 sgft Depth to FSH 3.5 ft Porosity Q- Inground Storage, SOO cubic feet Required Treatment Volume Provided Treatment Volume = 'Jo. 10 Gage ,tic Zip Ties 18" Min. Driven Post Embedment ELEVATION :3639 2999, 650 ided Storeee Area 2.1 S4 Bottom- 25, otto -25, 200 Top _Area _ 19 152 Bottom 23 276 Top Storage ft3 C 71 Storage ft3 t1 107 NOTES: 1. Temporary silt fence shall be installed prior to any grading work in the area to be protected. Fence shall be maintained throughout the construction period and removed in conjunction with the final grading and site 'stabilization. 2. Filter fabric shall meet the requirements of material specification 592 Geotextile Table 1 or 2, Class I with equivalent opening size of at Feast 30 for nonwoven and 50 for woven. 3. Fence posts shall be either wood post with a minimum cross-sectional area of 1.5" X 1.5" or a standard steel post. 4. When splices are necessary make splice at post according to splice detail. Place the end post of the second fence inside the end post of the first 'fence. Rotate both posts together at least 180 degrees to create a tight seal with the fabric material. Cut the fabric near the bottom of the posts to accommodate the 6 inch flap. Then drive both posts and bury the flap. Compact backfill well. 0 Z • U � � M 0 L N z M oL ;z -i Ln N � o M V Cq 0 > Q z �z OU 01% Z Qv �Q Qo :: Ln NOON NONE PROJECT #: 18-305 DESIGNED: Rotate DRAWN: KCM SCALE: Posts Filter Fabric Together n, _--•Direction Of FiOW Before Installation w U Undisturbed Ground Line First Fence Second SeeFence _ `o L 4 - Second First NOV 2 1 2013 Post Post Mn FABRIC ANCHOR DETAIL SPLICE DETAIL -PLAN VIEW 0 Z • U � � M 0 L N z M oL ;z -i Ln N � o M V Cq 0 > Q z �z OU 01% Z Qv �Q Qo :: Ln NOON NONE PROJECT #: 18-305 DESIGNED: KCM DRAWN: KCM SCALE: AS NOTED ISSUED: 11/16/18 REVISION -1: REVISION -2: 0 `0111111111111 G. •a No 8 9 �-:D'• STATE OF w 0. OR SHEET C �p,.�1 w M 0 O J ~ J oz o w zC LL X� w R'-0" EXISTING _. --- — ,..1 .TOTES ,ALE DRAWINGS. U9'E ONLY DIMENSIONS SHOWN ON 3. IF DIMENSIONS ARE IN QUESTION, THE BUILDER RESPONSIBLE FOR OBTAINING CLARIFICATION ONTINUING WITH CONSTRUCTION. BUILDER SHALL .L DIMENSIONS & CONDITIONS AT JOBSITE. NS SHOWN ARE TO ACE OF FRAMING OR NE OF STRUCURE UNLESS OTHERWISE NOTED. ,OORS SO THAT DOOR CASING ABUTS WALL FINISH OF T WALL UNLESS OTF ERWISE NOTED. SHALL COORDINATE ALL SHELVING & STORAGE GENTS WITH DESIGNER OR OWNER. 'ENT OF ANY DISCREPANCIES, IMMEDIATELY NOTIFY ER. DO NOT PROCEED WITH AFFECTED WORK UNTIL I ISSUES HAVE BEEN FULLY RESOLVED. ;TRUCTION SHALL B(= PERFORMED IN ACCORDANCE CODES, REGULATIgNS, AND RESTRICTIONS HAVING' TION. ELECTRICAL LEGEND TV CABLE 8 DUPLEX OUTLET L220 OUTLET WORK AREA - QUADRAPLEX OUTLET GFI GFI RECEPTACLE @ a EXTERIOR/GFI RECEPTACLE C SWITCH z 3 -WAY SWITCH SD SMOKE DETECTOR CM CARBON MONOXIDEDETECTOR CH COUNTERTOP HEIGHT NOTE: 1. TE: EPHONE OUTLETS TO BE 'CAT 5E' WIRE. 2. SN'JKE DETECTION PER FIRE CODE. 3. SE•�VICE PANEL AND ELECTRIC METER LOCATION TO BE DETERMINED W/ INPUT FROM THE OWNE -� AND LOCAL UTILITY COMPANY. 4. ALl RECEPTACLE TO HAVE ARC -FAULT CIRCUIT INTERRUPTERS PER ARTICLE 210-12. 5. HV;\C DISCONNECT TO BE PROVIDED BY MECH;\NICAL SUBCONTRACTOR. 6. ALL ELECTRICAL WIRING TO BE IN ACCORDANCE WITH LATEST EDITION OF NEC AND FBC. 7. 100',a OF ALL INTERIOR AND EXTERIOR PERMANENT LIGHT FIXTURES TO USE CFL/LED LAM P F 5'-0" OVERHANG IF_— ---- I o 00O I z`�0 �,LLTo O Q O w o Xo�Qo w mow_ � ow�o`I LCO owl I 4 p a z 19'-9" 13'-10" lo — — — — — — — — — — — — — — — — \ 20'-0" 17'-7" ALIGN W/ EXISTING \ 7-2" \V� OUTDOOR LIVING AREA VAULTED T&G CEILING PROVIDE SKYLIGHTS PER OWNER SELECTIONS & LOCATIONS _0•- I F —7 I I I I I I 1 130"X45.75" 1 LKY _IGHT� f 2'-8"x5' DH 2'-8" 5' DH WINDOW FIREPLACE V IN1 60W i T-0" 6-0" 1 T-0" FIRST FL SCALE: 1/4"1= 1'-0" YOUNG RESIDENCE RENOVATION PROJ ECT ADDRESS W U Al RENOVATION PLANS ATLANTIC BEACH, FL 32233 CY WORK AREA - +J w `1 O C NEW TOTAL A/C: 3,117 SQ. FT, NEW A/C VOLUME: 3,222 CU. FT. o� BUILDING CODE SUMMARY CODE ENFORCEMENT JURISDICTION: CITY OF ATLANTIC BEACH WIND ZONE: 130 MPH (WIND-BORNE DEBRIS) FLORIDA BUILDING CODE 2017 - 6TH EDITION I C CONSTRUCTION TYPE: TYPE V -B (WOOD FRAME ADDITION) U) FIRE DISTRICT: NO — � 0 F / (D I 1 TO MAX POSSIBLE I � 1 0"X45.75" I �KYLIGHTJ I F —7 I I I I I I 1 130"X45.75" 1 LKY _IGHT� f 2'-8"x5' DH 2'-8" 5' DH WINDOW FIREPLACE V IN1 60W i T-0" 6-0" 1 T-0" FIRST FL SCALE: 1/4"1= 1'-0" YOUNG RESIDENCE RENOVATION PROJ ECT ADDRESS DRAWING INDEX 1820 SHERRY DRIVE N. Al RENOVATION PLANS ATLANTIC BEACH, FL 32233 A2 EXTERIOR ELEVATIONS AND DETAILS WORK AREA - N EXISTING FIRST FLOOR A/C: 1,480 SQ. FT. EXISTING SECOND FLOOR A/C: 1,315 SQ. FT. NEW A/C: 322 SQ. FT. NEW TOTAL A/C: 3,117 SQ. FT, NEW A/C VOLUME: 3,222 CU. FT. H BUILDING CODE SUMMARY CODE ENFORCEMENT JURISDICTION: CITY OF ATLANTIC BEACH WIND ZONE: 130 MPH (WIND-BORNE DEBRIS) FLORIDA BUILDING CODE 2017 - 6TH EDITION OCCUPANCY CLASSIFICATION: RESIDENTIAL (R-3) CONSTRUCTION TYPE: TYPE V -B (WOOD FRAME ADDITION) SPRINKLED: NO FIRE DISTRICT: NO — A A2 ALIGN W/ EXISTING / i / I I LIVING 4-1 ROOM EXISTING 8' CLG Ld- ----- --- I I LO CLOSET 1 I w z 8' CLG i I Z MASTER 7 = I Q w 8'CLG 0Fa- < �X� 28 \\ I I LULU w0 \ _ �\ z z 0 I 3_0" 5'-6" EXIIN 2/6 2/4 4'x3' DH INDOW CH FI IS GFID REF \ 2/6 4" STE 1 11-6" 'Yt" (D MR IXE 1� 1 I w I I II� 11� 11 I z �I jf Iyj o 1 141.5"x4'1 I - 1 C C3PEf� ei-_CTWf-StKy_H&HT� KITCHEN _ — — — 10' CEILING OVEN NEW DESIGN BY OTHERS 3 REMOVE EXISTING WINC NEW CASED OPENING LC I FAMILY ROOM EXISTING OOR PLAN 10'-0" EXISTING 0 LAUNDRY REMOVE EXISTING KITCHEN CABINETRY, FIXTURES, APPLIANCES MUD ROOM BUILT-INS :XISTING ELECTRICAL TO REMAIN O � � � • Imo'''///����� � � e MR 5 EX / HVAC UNIT _C? ET GARAJ EXISTING �p R Y,,,• Julianne N. Overby,RA Architectural and Interior Design Julianne N. Overby, R.A. 2452 Pulhan Street Jacksonville Beach, Florida 32250 904-704-8628 Email: jnoverby@att.net FL. AR -0017060 • FL. ID -4621 W DINING U CY, M Z ROOM N WSJ o z TRAY CLG TO BE H U) w REMOVED AND Wo� o a CEILING HEIGHT zo P: o TO BE INCREASE (D T< U) TO MAX POSSIBLE Z U) (DZ w0 00 0�Q z w O w 2/6 0 Z Q 0 LAUNDRY REMOVE EXISTING KITCHEN CABINETRY, FIXTURES, APPLIANCES MUD ROOM BUILT-INS :XISTING ELECTRICAL TO REMAIN O � � � • Imo'''///����� � � e MR 5 EX / HVAC UNIT _C? ET GARAJ EXISTING �p R Y,,,• Julianne N. Overby,RA Architectural and Interior Design Julianne N. Overby, R.A. 2452 Pulhan Street Jacksonville Beach, Florida 32250 904-704-8628 Email: jnoverby@att.net FL. AR -0017060 • FL. ID -4621 W U CY, M Z ZN N WSJ pF�; H U) r) T_ Wo� W ��m w (D = U Z U) (DZ 00 0�Q DATE ISSUED: OCTOBER 19, 2018 NOTE: DO NOT SCALE DRAWINGS. IF PRINTED ON 11 "X17" MEDIA, DRAWING SCALE IS HALF -SIZED. RENOVATION PLANS.,--,, - ._ 23 2018 Departmer °: Al PERMIT SET WOOD FRAME GON9TRUCTION CODE COMP NT L'INDO IN6TA-'_ATION METHOD— WEAT'.lER R=51tIYE rsARR'ER !WRB! AFFLIE7 PRIOR TO TUE W'INCOL: IVBTALLATION. FLAB-IIN'% APPLI=D OVER -I"E FAGE C✓= THE fSOUVTINs FLAh'sE. SEC?'ON A %cam TVq=JG1J_yIN�QU i I; IV WATER b'#DpMG�.L'+''ON. -4E EMIL A T 'HE tOP pcOA�LALL L TIlC LLIQD ',}) 9E114Vi DEAD 6FEA 4V+ F.EHIVD r4JITRY.. � �� , a+L 'LL F.lSal� :+u6 1 FLANGE.—.• T BA K CF WINDOJ / \ 4 AJ OO`W q D6 A. TO g _NE W E TD DPEN G .� c.e oue eE -- 01TOr F -?JW EAAIK. 1 M E 10'L OF THE NDGl1 F1 -A L N= C %T ? 5 1 T -I >V* PRE =sIGHEc SOL a OR sL 5. { .I� � I CU u5 ' Ati ECAC i � � Rre.lMG � `� SGREyS TO F-ILIT.+TE {{ L -SEALANT DEAD B=_TtJED: (S�J:+MB FLA$LIING FLg0HI1.G ANp HO n-FL—E. (5) ADPL 6 FLABHIw '{ 'x'L.' RJI. SEA TO iH YOJNTrk+ MKaES AT THE TOF FEZND vpE9 lJA"iD DF UINDOJI. n?' BE D C'.F SEALgVT {{ � EMeL 'A^18 PLASHING ; O 5E."L N ..ND FASTEN/ �....� M FLAi%. (FSA alaG�b OYF d_AVT). (� AMPLY H=AD F' Ab-I'V'a 11ffM0�£ PRENOJBLt' +1PPLIED 1 / APE Y =AD FLA 7 {{ -� iBEGURE WRB Pf L FLW 6HCATH NG TAPE V , O'FR " , I I , AT'HEAD I 1/ AT HEAD { J DEYOND JArID R n•G (1),4 AP LA5-NG {{ I l (1 �j D. TOO' P �IOI.sLY '`�SEaL,NT- APPLE7.aEAL.J. fFL >~MG GOE5 OYER 9E. -t- NTJ £ifTEVD HEAD I / A �SIJArl> ✓=1 48H - / E TEND FL ASH— TO �� FL sH r�iG vice tLa� , I SEALAN � Y ilii ' Sr L L19HRV' \• <�� DOJ C f ":1 PJMB. AND LE /E L�ITO\ I15=CORR090V `�I}� (� rC09'AVT FL9 -n RS. A9 En WN�OW -R �) �\ yp.ppy ,•nVFlLT1RER 9P'c I CATIONS, T .0)L•EATF-ER REB STAN'. •- {9 D£GREE AKLE. OP'�PJLL'r� -� 1 - BARR=R ONADIgGWg4 G -N TE I• TOP EG'£. 6 "NE DAA R LF AN FE TaE '.. I TOP GORIERS ANp CEN1=R TO TF=-XTERIOR :T 9UF9:/-E N ERIOR VIEJU TOS LE- GORVER 0= W'.NDOW 1 NOTES: 1. flashing to be flewble self-adhesive type (min. 4" wide) t° still pan flashing 2, cover sill to at least depth of window, plus 2" onto face of wl sloped surface ( optional) 3. the pan shall direct water to the exterior over sill flashing Isill plate 4. install flashing around remaining window unit weather resistive banter to form water shedding laps see noa#2J'� - afl�' SILL PAN FLASHING _ weather resistive barrier NTS (ortTonal) wall sheathing -- 9- I-1 -2013 P•epared by BOAF Ffrat Coast Chapter NOTE: THIS DETAIL USED FOR DOORS R&WI . WINDOW ALL FLASHING TO MEET FBC R903.2.1, 90 R703.8 AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. METAL DRIP OVER \ VINYL FASCIA OVER 2X6 SUB FASCIA TO MATCH EXISTING VARIES MATCH EXISTING OVERHANG 2X4 EXTERIOR WALLS W/ 2" OSB SHEATHING WRAPPED IN WATERPROOFING MEMBRANE INSTALL HARDIPLAI•1K LAP SIDING PER MANUFACTURER'S RECOMMENDATION �J R-38 INSULATION 1/2" GYP. BOARD -13 INSULATION dam•—e SLOPE _ -III-I►1-1�1 II 1�1-1►1 511 I II 111 -III —III III _ I-1 1 11-1 1 e: e e e� e e •a 1-1 d� e II—III—° m_ a _ 1II =1 I I=1 I I-III-III=1 I I=1 I I=1 I I 0 t 0 2"x4" BOTTOM PLATE IEIE NEW7LINE TO MATCH EXISTING CLG. = 8'-0" 02 I -- o - ITI —kXTERIOR FINISH Lt zTO MATCH EXISTING _ - F.F_ = 0'-0 - _ - STEM WALL PAINTED NEVIII'CLOSET ADDITION TO ALIGN W/ EXISTINGL A REAR ELEVATION - SCALE: 1/4" = T-0" 4" CONCRETE SLAB OVER 1 12 ASPHALT SHINGLE - SEE STRUCTURAL ROOF ON 15# ROOFING 6 MATCH EXISTING TO MATCH EXISTING GROUT FILLED 8" FELT OVER 7/16" STEMWALL EXT. SHEATHING CONT. CONCRETE FOOTING i METAL HURRICANE CLIP AS REQUIRED BY CODE - SEE STRUCTURAL s METAL DRIP OVER \ VINYL FASCIA OVER 2X6 SUB FASCIA TO MATCH EXISTING VARIES MATCH EXISTING OVERHANG 2X4 EXTERIOR WALLS W/ 2" OSB SHEATHING WRAPPED IN WATERPROOFING MEMBRANE INSTALL HARDIPLAI•1K LAP SIDING PER MANUFACTURER'S RECOMMENDATION �J R-38 INSULATION 1/2" GYP. BOARD -13 INSULATION dam•—e SLOPE _ -III-I►1-1�1 II 1�1-1►1 511 I II 111 -III —III III _ I-1 1 11-1 1 e: e e e� e e •a 1-1 d� e II—III—° m_ a _ 1II =1 I I=1 I I-III-III=1 I I=1 I I=1 I I 0 t 0 2"x4" BOTTOM PLATE IEIE NEW7LINE TO MATCH EXISTING CLG. = 8'-0" 02 I -- o - ITI —kXTERIOR FINISH Lt zTO MATCH EXISTING _ - F.F_ = 0'-0 - _ - STEM WALL PAINTED NEVIII'CLOSET ADDITION TO ALIGN W/ EXISTINGL A REAR ELEVATION - SCALE: 1/4" = T-0" 4" CONCRETE SLAB OVER 1 VAPOR BARRIER SEE STRUCTURAL DRAWING 1/2" EXP. JOINT GROUT FILLED 8" CMU STEMWALL CONT. CONCRETE FOOTING SEE STRUCTURAL DRAWINGS - ADDITION WALL SECTION SIDE ELEVATIO A2 SCALE: 1/4" = T-0" A2 S',ALE:3/4" = T-0" i F.F. _ 41 muur r�H�� SCALE: 1/8" = T-0" -^ ACCENT STONE CHIMNEY STACK NEW ROOF LINE TO BE OVER -FRAMED & MATCH EXISTING 7F -0",OVERIVAC / I EXTERIOR FINISH TO MATCH EXISTING \ F.F. = 0'-011 STEM WALL PAINTED TO MATCH NEW KITCHEN ADDITION TO ALIGN W/ EXISTING ROOF LINE TO MATCH EXISTING 20'-0" NEW OUTDOOR LIVING AREA ADDITION - VAULTED CEILING ACCENT STONE CHIMNEY STACK 12 CONFIRM 6 z EXISTING 1- EXISTING TO REMAIN Cl) wz S. U. INEWROOFLINEC EXISTING ;?�i_ L 1 z I MOVE EXIS I'NG EXTERIOR FINISH TO MATC I EXISTING w ENCH DOQ RS 1 U RUCTURAL 0 oil 00 PR IDE HEADE, FOR NE 12' SLIDERI )OOR I i � NEW CLOSET ADDITION TO A-IGN W/ EXISTING B SIDE ELEVATION NA2 SCALE: 1/4" = T-0" VAULTED T&G CEILING Aj' OUTDOOR LIVING A EA EXTERIOR FINISH TO MATCH EXISTING STEM WALL PAINTED TO MATCH NEW ADDITION TO ALIGN W/ EXISTING CLG.=10'-0" F.F. = -411 COMMUNITY DEVELOPMENT APPROVED TING TO REMAIN NEW CLG. = 10'-0" EX Ti " = 8'-0" RV • ' -^� ll� `1 WJ Julianne N - Overby,RA Architectural and Interior Design Julianne N. Overby, R.A. 2452 Pullian Street Jacksonville Beach, Florida 32250 904 -704 - Email: jnoverby@att.net FL. AR -0017060 • FL. ID -4621 w U' Z, W D'. W C7 z :DO M M Z N N W M J LL I..L 0 �0 �Q (YOO W W m __U U) _ p Z N Q 0 DATE ISSUED: OCTOBER 19, 2018 NOTE: DO NOT SCALE DRAWINGS. IF PRINTED ON 11"X17" MEDIA, DRAWING SCALE IS HALF -SIZED. EXTERIOR ELEVATIONS AND I LS ;+ r01, PERMIT SET W N Al A GARAGE FRONT ELEVATION A3 SCALE: 114'' = T-0" _------ ;'8"x5' DH VANDOW I I I I \ I I L � I I \ C A3 //0 r I � I I I 2'8"x5' DH WINDOW L- - - - - - - - - - - - 4'-6" PATIO 10'-0" GARAGE FLOOR PLAN B , SCALE: 1/4" = 1'-0" A3 GARAGE SIDE ELEVATION A3 SCALE: 1/4'' = 1'-0" i� F81 III Julianne N . Overby, RA Architectural and Interior Design Julianne N. Overby, R.A. 2452 Pulhan Street Jacksonville Beach, Florida 32250 904-704-8628 Email: jnoverby@att.net FL. AR -0017060 - FL. ID -4621 W U r, M Z Z N N w w M > J D2C w ry W EY� W m Ur 2U) U ho z : D� CN J O � Q DATE ISSUED: OCTOBER 19, 2018 NOTE: DO NOT SCALE DRAWINGS. IF PRINTED ON 11"X17" MEDIA, DRAWING SCALE IS HALF -SIZED. DETACHED GARAGE PLAN AND ELEVATIONS �pRIDq A3 GARAGE REAR ELEVATION k�•RB A3 SCALE: 1/4" = 1' Jp�', Y PERMIT SET GENERAL DEMOLITION NOTES: 1. ALL DEMOLITION WORK TO BE PERFORMED UNDER G.C. CONTRACT. G.C. TO FIELD VERIFY ALL EXISTING CONDITIONS. 2. SURVEY EXISTING CONDITIONS OF THE BUILDING TO DETERMINE IF REMOVING ANY ELEMENT MIGHT RESULT IN STRUCTURAL DEFICIENCY TO ANY PORTION OF THE STRUCTURE OR ADJACENT STRUCTURES. NOTIFY THE ARCHITECT AND STRUCTURAL ENGINEER IN WRITING PRIOR TO COMMENCING ANY ADDITIONAL WORK FOR DIRECTION IF DEFICIENCIES ARE NOTED. 3. TURN OFF NECESSARY POWER AND UTILITIES PRIOR TO COMMENCING ANY DEMOLITION WORK. 4. ITEMS INDICATED TO BE REMOVED SHALL BE REMOVED AND LEGALLY DISPOSED OF IN ACCORDANCE WITH APPLICABLE CODES. 5. PROTECT EXISTING ITEMS TO REMAIN. THESE ITEMS TO BE COORDINATED WITH THE OWNER PRIOR TO ANY DEMO WORK. 6. DEMO AND REMOVE EXISTING INTERIOR DOOR / DOOR FRAME / DOOR SILL / CASING UNLESS OTHERWISE NOTED (U.O.N) ON PLAN. 7. CUT OPENINGS NEATLY AND HOLES PLUMB, SQUARE AND TRUE TO DIMENSIONS REQUIRED. USE CUTTING METHODS LEAST LIKELY TO DAMAGE CONSTRUCTION TO REMAINING OR ADJOINING CONSTRUCTION. 8. ANY FIRE EXTINGUISHERS TO BE REMOVED AND STORED FOR FUTURE USE. 9. AUTHORIZED CONSTRUCTION PERSONNEL ONLY WITHIN THE CONSTRUCTION AREA. 10. WORK TO BE DONE IN SUCH A MANNER AS TO HAVE MINIMUM DISRUPTION TO ONGOING CITY BUSINESS AND PARKING LOT. 11. CODES AND REGULATIONS: COMPLY WITH GOVERNING CODES AND REGULATIONS. 12. USE EXPERIENCED WORKERS. 13. OCCUPANCY: IMMEDIATE AREAS OF WORK MAY BE OCCUPIED DURING DEMOLITION BY THE HOME OWNERS. 14. DEMOLISH DESIGNATED IMPROVEMENTS AS NECESSARY TO IMPLEMENT RENOVATION PLAN. 15. IMPLEMI�NT POLLUTION CONTROL DURING BUILDING DEMOLITION. 16. HAZARDOUS MATERIALS: IF HAZARDOUS MATERIALS ARE NOTED THEY WILL BE REMOVED UNDER SEPARATE CONTRACT, NOTIFY OWNER IF HAZARDOUS MATERIAL IS DISCOVERED TO BE PRESENT. 17. DO NO1 DAMAGE BUILDING ELEMENTS AND IMPROVEMENTS INDICATES TO REMAIN. ITEMS OF SALVAGE VALUE, NOT SPECIFIED ITEMS TO BE RETURNED TO OWNER, SHALL BE REMOVED FROM STRUCTURE. STORAGE OR SALE OF ITEMS IS PROHIBITED. 18. UTILITIES: LOCATE, IDENTIFY, DISCONNECT, AND SEAL OR CAP OFF UTILITIES IN AREAS TO BE DEMOLISHED. 19. SHORING AND BRACING: PROVIDE AND MAINTAIN INTERIOR AND EXTERIOR SHORING AND BRACING AS REQUIRED. 20. OCCUPIED SPACES: DO NOT CLOSE OR OBSTRUCT STREETS, WALKS, DRIVES, PARKING SPACES OR OTHER OCCUPIED OR USED SPACES OR FACILITIES WITHOUT THE WRITTEN PERMISSION OF THE OWNER AND THE AUTHORITIES HAVING JURISDICTION. DO NOT INTERRUPT UTILITIES SERVING OCCUPIED OR USED FACILITIES WITHOUT THE WRITTEN PERMISSION OF THE OWNER AND AUTHORITIES HAVING JURISDICTION. IF NECESSARY, PROVIDE TEMPORARY UTILITIES. 21. RESTORATION: RESTORE FINISHES OF PATCHED AREAS. DEMOLITION KEY NOTES 1. REMOVE ALL WALL PARTITIONS INDICATED BY DASHED LINES, INCLUDING ALL GLAZING AND TRIM. 2. REMOVE ALL MILLWORK, INCLUDING ALL PLUMBING FIXTURES & APPLIANCES INDICATED BY DASHED LINES. 3. REMOVE ALL EXISTING FLOORING AND WALL FINISHES SHOWN FOR DEMOLITION ON THESE DRAWINGS. PATCH UNEVEN SURFACES AND PREPARE FOR NEW FINISHES. 4. REMOVE EXISTING DOOR/WINDOW AND FRAME. PREPARE FOR NEW WALL AND/OR OPENING AS SHOWN IN NEW PLAN. u ly 1 N N BEDROOM CLOSET BEDROOM EXISTING EXISTING EXISTING REMOVES & INFILL EXISTING DOO\R A I OFFICE \ I \ EXISTING loo \— — — — — — — Q Cl) �0 �O W J Z / II / II PLAYROOM ® EXISTING 0 0 II II STORAGE EXISTING BEDROOM EXISTING SECOND FLOOR DEMOLITION PLAN SCALE: 1/4" = T-0" LIVING ROOM EXISTING 8' CLG MASTER BATH EXISTING EXISTING IQ)]— 4" STEP KITCHEN // EXISTING PREVIOUS EXTERIOR - 0? WALLS TO BE REMOVED N REMOVE STRUCTURAL ENGINEER TO & INFILL ® \ REDESIGN W/ BEAMS TO ALLOW FOR EXISTING DOOR 8' CEILING HEIGHT TO CONTINUE ADDITION 4" SLAB TO BE REMOVED w z 2 REMOVE FINISHED FLOOR TO ALIGN WITH Fw 0 EXIST�NG EXISTING LIVING ROOM FINISHED 4 v SHGWER FLOOR 3: � I PREPARE LIMIT OF SLAB DEMO z FOR NEW _ EXISTING NEW 4" STEP LOCATION TOILET TO REMAIN II MASTER BATH 2U 2Q EXISTING d O _� I MASTER I I i CLOSET o / i REMOVE f � DINING KITCHEN I EXISTING EXISTING VANITY ROOM REMOVE REMOVE ALL 1 3 PREPARE FOR NEW EXISTING CY, M TRAY CLG TO BE CABINETRY, I I / TUB N REMOVED AND APPLIANCES & I jl PREPARE / M CEILING HEIGHT PLUMBING FOR NEW J TO BE INCREASE — FIXTURES TO BE LL -O MAX POSSIBLE Li RELOCATED IN 2 NEW KITCHEN LOCATION i - O GARAGE EXISTING ONE, ■ ' RIDq RBY , .. W Julianne N - Overby, RA Architectural and Interior Design Julianne N. Overby, R.A. 2452 Pullian Street Jacksonville Beach, Florida 32250 904-704-8628 Email: jnoverby@att.net FL. AR -0017060 - FL. ID -4621 W U CY, M Z ZN N W w M J Q � LL U) D 2 w � w ry �m W D 2U) U z p Z : D C\1 00 < O T Q DATE ISSUED: OCTOBER 19, 2018 NOTE: DO NOT SCALE DRAWINGS. IF PRINTED ON 11 "X17" MEDIA, DRAWING SCALE IS HALF -SIZED. DEMOLITION PLANS PE 3 201 D 1 PERMIT SET U It °0 r Lu Z 0 V) O Z U- J Z 0 z 0 z w Z U-1 Lu V) z Q o' r) Lu J N O z 0 J J Z w Lu Lu z z Lu z Q Z w Ln Z 0 z w w w CL 0 3. w O' N 00 ON �z >- 0 Z ,- Qp zz �0 Qq cece z 0< ON Z 00 uj Z ::> Lu� UQ c))- 0 , LJ CL w> w p ce z OQ n� ujw wU m F- J 0= ZN Q O 0 = Ln U V)Q Uz 70 U Oo C? Q wX 00 �CL QCLQ QLu �w Lu Q� �Z Z0 Lu �w �Q �z Z O Z Lu <� r� Uuj J w J Z z CZ LU ww w z_ F_ (D _ w? Z vi < Q -O N � Z LU C-4 o0 GENERAL STRUCTURAL NOTES THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOBSITE PRIOR TO COMMENCING WORK. CONTRACTOR SHALL REPORT ALL DISCREPANCIES THE DRAWINGS AND EXISTING CONDITION TO THE ENGINEER PRIOR TO COMMENCING WORK. DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE TYPICAL AND APPLY TO SIMILAR SITUATIONS ELSEWHERE, EXCEPT AS OTHERWISE INDICATED. ADAPT REQUIREMENTS OF DETAILS, SECTIONS, PLANS, AND NOTES AT LOCATIONS WHERE CONDITIONS ARE SIMILAR. DIMENSIONS INDICATED ON THE DRAWINGS IN REFERENCE TO EXISTING CONDITIONS ARE THE BEST AVAILABLE DATE OBTAINABLE, BUT ARE NOT GUARANTEED. BEFORE PROCEEDING WITH ANY WORK DEPENDENT ON THE DATA INVOLVED, THE CONTRACTOR SHALL FIELD CHECK AND VERIFY ALL DIMENSIONS, GRADES, LINES, LEVELS, OR OTHER CONDITIONS OF LIMITATIONS AT THE SITE TO AVOID CONSTRUCTION ERRORS. IF ANY WORK IS PERFORMED BY THE CONTRACTOR OR ANY OF HIS SUBCONTRACTORS PRIOR TO ADEQUATE VERIFICATION OF APPLICABLE DATA, AT RESULTANT EXTRA COST FOR ADJUSTMENT OR WORK AS REQUIRED TO CONFORM TO EXISTING LIMITATIONS, SHALL BE ASSUMED BY THE CONTRACTOR WITHOUT REIMBURSEMENT OR COMPENSATION BY THE OWNER. CENTER ALL FOOTINGS AND PIERS UNDER COLUMNS ABOVE UNLESS SPECIFICALLY DIMENSIONED OTHERWISE. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SITE DRAWINGS, CONSULT THESE DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS. EXCAVATION FOR BUILDING FOUNDATIONS, THE S RUCTLENGINEER SHALL BE NOTIFIED OF POTENTIAL CSHALL LOTE ALL BURIED UTILITIES PRIOR TO URAONFLIICTS BETWEEN FOUNDATIONS AND BURIED UTILITIES. CODE REQUIREMENTS: THE BUILDING STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE 2017 EDITION OF THE FLORIDA BUILDING CODE 6TH EDITION. OTHER CODES IMPLEMENTED FOR DESIGN INCLUDE: ASCE7-10, ACI 315/318/530, NDS 2015, APA, A.I.S.C., ANSI. FOLLOW ALL APPLICABLE PROVISIONS OF THE FLORIDA BUILDING CODE AND OTHER RELATED CODES FOR ALL PHASES OF CONSTRUCTION. TEMPORARY CONDITIONS: THE STRUCTURAL INTEGRITY OF THE COMPLETED STRUCTURE DEPENDS ON INTERACTION OF VARIOUS CONNECTED COMPONENTS. PROVIDE ADEQUATE BRACING, SHORING, AND OTHER TEMPORARY SUPPORTS AS REQUIRED TO SAFELY COMPLETE THE WORK. THE STRUCTURE SHOWN ON THE DRAWINGS HAS BEEN DESIGNED FOR STABILITY UNDER FINAL CONFIGURATION ONLY. FOUNDATIONS: FOUNDATIONS ARE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PSF ON COMPACTED FILL. NO GEOTECHNICAL REPORTS AND/OR IN-SITU SOIL DATA WAS GIVEN TO THE STRUCTURAL ENGINEER PRIOR TO DESIGN. THE BEARING CAPACITY USED FOR DESIGN IS BASED ON ALLOWABLE LOADS FROM THE FLORIDA BUILDING CODE, 2017 FOR SANDY SOILS WITH NO CLAY, ORGANIC MATERIAL, OR OTHER DELETERIOUS MATERIALS THAT WOULD AFFECT DESIGN BEARING PRESSURE AND THE PERFORMANCE OF THE FOUNDATIONS. BEFORE CONSTRUCTION COMMENCES, SOIL BEARING CAPACITY SHALL BE VERIFIED BY A SUBSURFACE INVESTIGATION,AS WELL AS FIELD AND LABORATORY TESTS PERFORMED BY A CERTIFIED TESTING LABORATORY, WHOSE REPORT SHALL INCLUDE ANALYSIS AND RECOMMENDATIONS FOR SITE PREPARATION IN ORDER TO BEAR THE FOUNDATION LOADS. ABOVE REPORT SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW BEFORE FOUNDATION CONSTRUCTION BEGINS. CONCRETE: REINFORCED CONCRETE CONSTRUCTION SHALL CONFORM TO THE FBC AND ACI 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE". CONCRETE STRENGTHS SHALL BE VERIFIED BY STANDARD 28 -DAY CYLINDER TESTS PER ASTM C39, AND SHALL BE AS FOLLOWS: fc ABS W/C MIN CEMENTSLUMP USE 2,500 PSI 0.58 470 LBS 5" +/- 1 ALL SLABS, MONOLITHIC FOOTINGS, SPREAD FTG 3,000 PSI 0.58 470 LBS 5" +/-1 TIEBEAMS, COLUMNS, WALLS, ELEVATED SLABS CEMENT SHALL CONFORM TO ASTM C150, TYPE 1. FLY ASH CONFORMING TO ASTM C618, TYPE F OR TYPE C, MAY BE USED TO REPLACE UP TO 20% OF THE CEMENT CONTENT, PROVIDED THAT THE MIX STRENGTH IS SUBSTANTIATED BY TEST DATA. COARSE AGGREGATE SHALL CONFORM TO ASTM C33 WITH A MAXIMUM SIZE OF 3/4". FINE AGGREGATE SHALL BE CLEAN, DURABLE, NATURAL SAND CONFORMING TO ASTM C33. A WATER -REDUCING ADMIXTURE CONFORMING TO ASTM C494, USED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, SHALL BE INCORPORATED IN CONCRETE DESIGN MIXES. A HIGH -RANGE WATER -REDUCING ADMIXTURE CONFORMING TO ASTM C494, TYPE F OR G, MAY BE USED IN CONCRETE MIXES, PROVIDING THAT THE SLUMP DOES NOT EXCEED 8". SLEEVES, OPENINGS, CONDUIT, AND OTHER EMBEDDED ITEMS NOT SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE APPROVED BY THE STRUCTURAL ENGINEER BEFORE POURING. NO SLEEVE, OPENING, OR INSERT MAY BE PLACED IN BEAMS, JOISTS, OR COLUMNS UNLESS APPROVED BY THE ENGINEER. CONDUITS EMBEDDED IN SLABS SHALL NOT BE LARGER IN OUTSIDE DIMENSION THAN ONE THIRD OF THE THICKNESS OF THE SLAB AND SHALL NOT BE SPACED CLOSER THAN THREE DIAMETERS ON CENTER. PROVIDE 3/4" CHAMFERS ON ALL EXPOSED CONCRETE EDGES, UNLESS NOTED OTHERWISE. WHERE INDICATED OR REQUIRED, SLOPE CONCRETE SLABS TO DRAINS SHOWN ON PLUMBING AND/OR ARCHITECTURAL DRAWINGS. ALL CONCRETE SHALL BE CURED IMMEDIATELY AFTER FINISHING OPERATIONS. WEATHER RESISTANCE: ALL CONCRETE INCLUDING BALCONY CONCRETE EXPOSED TO CHLORIDES SHALL CONTAIN A CALCIUM -NITRITE BASED CORROSION -INHIBITING ADMIXTURE. THE DOSAGE FOR CONCRETE EXPOSED TO AIRBORNE CHLORIDES SHALL BE MINIMUM TWO GALLONS PER CUBIC YARD. THE WATER CONTAINED IN THE CORROSION -INHIBITING PADMIXTURE SHALL BE ROVIDE RHEOCRETE USED IN THE CALCULATION OF THE TITIOUS RATIO OF THE CONCRETE. BY MASTER BUILDERS OR APPROVED EQUIVALENT.CONCRETE BALCONIES OR OTHER CONCRETE FLAT SURFACES EXPOSED TO THE WEATHER THROUGHOUT THE LIFE OF THE BUILDING, SHALL BE TREATED WITH A CLEAR NONFLAMMABLE PENETRATING SEALER OF THE ALKYL ALKOXY SILANE CLASSIFICATION, SUCH AS SONNEBORN PENETRATING SEALER 20, HYDROZO ENVIROSEAL 20, OR OTHER APPROVED WEATHER RESISTANT SYSTEM. APPLICATION AND SURFACE PREPARATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. SHORING AND RESHORING: SHORING AND RESHORING SHALL CONFORM TO ACI 347R-88. SHORING AND SUPPORTING FORMWORK SHALL NOT BE REMOVED FROM HORIZONTAL MEMBERS BEFORE CONCRETE STRENGTH IS AT LEAST 70 PERCENT OF DESIGN STRENGTH, AS DETERMINED BY FIELD CURE CYLINDERS. IN ADDITION, SHORING SHALL NOT BE REMOVED SOONER THAN RECOMMENDED BY ACI 347R-88, SECTION 3.7.2.3. FORMWORK SHALL NOT BE REMOVED IN LESS THAN TEN (10) DAYS. PRECAST CONCRETE LINTELS: UNLESS INDICATED OTHERWISE, ALL LINTELS TO BE "U" TYPE PRECAST CONCRETE UNITS EQUAL TO UNITS MANUFACTURED BY CAST -CRETE CORP. AND PRESTRESSED (AND ADDITIONALLY REINFORCED AS REQUIRED) IN ACCORDANCE WITH CAST CRETE CORP. "DESIGN MANUAL", LATEST EDITION, FOR THE SPAN AND LOADING CONDITION RELATIVE TO LINTEL LOCATION. LINTEL SIZE IF NOT SHOWN ON THE PLANS SHALL BE 8F8-1 B FOR OPENINGS LESS THAN 10 FEET AND 8F16-1 BMT FOR OPENINGS 10 FEET TO 20 FEET. PROVIDE 8" MINIMUM BEARING FOR LINTELS UNLESS NOTED OTHERWISE. WOOD: SAWN LUMBER SHALL BE SOUTHERN PINE #2 WITH THE ALLOWABLE FIBER STRESSES PER THE AWC NATIONAL DESIGN SPECIFICATION. ALL MANUFACTURED LUMBER SHALL BE 2.0E GLUED LAMINATED GEORGIA PACIFIC (OR EQUIV.) AND INSTALLED ACCORDING TO MANUFACTURES RECOMMENDATIONS. ALL HEADERS/BEAMS SHOULD BEAR FULLY ON POSTS AND/OR MULTI STUD GROUPS UNLESS NOTED OTHERWISE ON PLANS. CONTACT ENGINEER OF RECORD IF HEADER/BEAMS SIZE IS NOT SPECIFIED, FRAMING ACCESSORIES AND STRUCTURAL FASTENERS SHALL BE MANUFACTURED BY SIMPSON COMPANY OR USP (OR APPROVED EQUAL) AND OF THE SIZE AND TYPE SHOWN ON THE DRAWINGS. HANGERS NOT SHOWN SHALL BE SIMPSON HU OF SIZE RECOMMENDED FOR MEMBER. ALL CONNECTORS SHALL BE UNLESS OTHERWISE, INSTALL MAXIMUM SIZE AND NUMBER OF FASTENERS SHOWN IN LATESTLSIMPSON CATALOG SHOWN ALL FRAMING NAILS SHALL BE COMMON NAILS AND SHALL BE OF THE SIZE AND NUMBER INDICATED ON HE DRAWINGS. MINIMUM NAILING REQ. NOT SHOWN SHALL BE AS INDICATED IN TABLE 2304.9.1 OF THE FBC. INSTALL BOLTS AD LAG SCREWS SHALL TO ANSI/ASME STANDARD B 8E1S ALL IBOLDS TS AND LA CREWS SHAIE ON THE PLANS ORLL BE INSTAL D WITH STANDARD CUONFORM WASHERS. ALL ANCHOR BOLTS AND THREADED ANCHOR RODS SHALL BE IN ACCORDANCE WITH ASTM A307, GRADE A, OR ASTM F1554, GRADE 36. ANCHOR ADHESIVES SHALL BE EITHER SET (EPDXY-TIE) OR AT (ARCYLIC-TIE) BY SIMPSON STRONG -TIE AND INSTALLED TO THEINSTRUCTIONS. ALL DRILLED SHALL BE CLEANED OF ALL DEBRIS ANID NG BRUSHED OUT PRIOR OSINSTALLLATION OF ANCHOR ADHESIVE ANCHOR HOLES ALL WOOD MEMBERS EXPOSED TO EXTERIOR CONCRETE, MASONRY, WEATHER, OR EARTH SHALL BE PRESSURE TREATED LUMBER. ALL NAILS DIRECTLY EXPOSED TO WEATHER SHALL BE GALVANIZED. FASTENER REQUIREMENTS IN PRESSURE TREATED LUMBER ARE AS FOLLOWS: ACZA PRESERVATIVE: STANDARD CARBON STEEL. ACQ & MCQ PRESERVATIVE: HOT DIPPED GALVANIZED. SODIUM BORATE: STAINLESS STEEL CONNECTORS & FASTENERS (NOT REQ. FOR SILL PLATES OVER CONCR. & VAPOR BARRIER NOT DIRECTLY EXPOSED TO EARTH OR WEATHER) ALL DECKS, GUARDS, RAILS, STAIRS AND OTHER ACCESSORY DECK COMPONENTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH AWC DCA6 PRESCRIPTIVE GUIDE FOR DECK CONSTRUCTION & THE FLORIDA BUILDING CODE, 2017. ALL FASTENERS AND CONNECTORS EXPOSED TO SALT WATER OR LOCATED WITHIN 300 FEET OF A SALT - OAA no 4442 ALL EXTERIOR WOOD WALLS WITHOUT OPENINGS SHALL BE CONSIDERED SHEAR WALLS. ALL WOOD DESIGN SHALL BE IN ACCORDANCE WITH THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, 2015 & WITH THE FLORIDA BUILDING CODE, 2017. PLYWOOD PANELS SHALL CONFORM TO THE REQUIREMENTS OF "U.S. PRODUCT STANDARD PS -1 FOR CONSTRUCTION AND INDUSTRIAL PLYWOOD" OR APA PRP -108 PERFORMANCE STANDARDS. UNLESS OTHERWISE NOTED, PANELS SHALL BE APA RATED SHEATHING, EXPOSURE 1, OFT E THICKNESS AND SPAN RATING SHOWN ON THE DRAWINGS. PLYWOOD INSTALLATION SHALL BE IN CONFORMANCE WITH APA REC �MMENDATIONS. ALLOW 1/8" SPACING AT PANEL EDGES, UNLESS OTHERWISE RECOMMENDED BY THE PANEL M PNUFACTURER. ALL SUB -FLOORING, ROOF, AND SHEARWALL SHEATHING SHALL BE INSTALLED WITH FACE GRAIN PERPENDICULAR TO SUPPORTS, EXCEPT AS INDICATED ON THE DRAWINGS. STAGGER � NDS OF ADJACENT PANELS 4'-011 . ROOF SHEATHING SHALL BE BLOCKED, TONGUE -AND -GROOVE, OR HA �E EDGES SUPPORTED BY PLYCLIPS. ATTACH PLYWOOD PANELS TO SUPPORTING MEMBERS WITH 10d NAIL SPACED 4" ON CENTER ALONG THE PANEL EDGES AND AT 6" ON CENTER ALONG INTERMEDIATE SUPPORTS, UNL SS NOTED OTHERWISE. SUB -FLOORING SHEATHING SHALL BE UNBLOCKED, EXCEPT AS INDICA ED ON DRAWINGS. ATTACH PLYWOOD PANELS TO SUPPORTING MEMBERS WITH 8d NAILS SPACED 4" ON CEN ER ALONG THE PANEL EDGES AND AT 8" ON CENTER ALONG INTERMEDIATE SUPPORTS, UNLESS NOTED OTHER WI�II E. PREFABRICATED WOOD TRUS`ES: SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WIT6 THE DESIGN INTENT OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONT �CTOR TO VERIFY COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIM NSIONS, ETC. CONTRACTOR SHALL NOT BE RELIEVED FROM RESPONSIBILITY FOR ERRORS OR OMISSIONS IN SHOP DRAWINGS OR MIX DESIGNS BY THE ENGINEER'S REVIEW. DESIGN AND MANUFACTURE IN ACCORDANCE WITH TPI "DESIGN SPECIFICATIONS FOR METAL PLATE CONNECTED WOOD TRUSSES", LATEST EDITION. ROOF TRUSS LOADING: SEE TRUSS MANUFACTURES SIGNED AND SEA TRUSS SHOP DRAWINGS FOR APPLICABLE TRUSS DESIGN LOADS. TRUSS LOADINGS SHALL BE BASED ON THE PR JECTS DESIGN LOADS AND THE MINIMUM LOAD REQUIREMENTS SET FORTH BY ASCE 7-10 AND THE FLORIDA BUII.DING CODE, 2017 RESIDENTIAL. ALL TRUSS TO TRUSS CONNECTIONS TO BE DESIGNED BY TRUSS MAN OFACTURER AND MADE USING TRUSS HANGERS. TRUSS DIAGRAMS, IF SHOWN, ARE DIAGRAMMATIC ONLY. RUSS DESIGNER TO DETERMINE AND ESTABLISH EXACT HEIGHT, LENGTH, LOCATION, SPACING, AND WEB M MBER FOR EACH TRUSS. COORDINATE WITH ARCHITECTURAL AND MECHANICAL DRAWINGS FOR ADDITIONAL ITEMS INCLUDING AIR HANDLER LOCATIONS, MECHANICAL ROOMS AND DUCT SPACE AND ROUTING. BUILDER SHALL COORDINATE WITH TRUSS DESIGNER FOR PERMANENT TRUSS BRACING. IF NO BRACING INFORMATION IS PROVIDED, BOTTOM CHORD LATERAL BRACING SHA111LS BE CONTINUOUS FROM ONE END OF THE BUILDING TO THE OTHER AND SHOULD OVERLAP AT LEAST ONE TRUSSPACE FOR CONTINUITY. LATERAL BRACING SHALL BE NAILED TO EACH TRUSS WITH A MIN. OF (2) 16d N INCLUDING INTERMEDIATE TRUSSES. SEE TRUSS SHOP DRAWINGS FOR OTHER DETAILS ND SPECIFICATIOS FOR BRACING. REINFORCING STEEL: REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, FOR DEFORMED BAR AND ASTM A185 FOR SMOOTH WELDED WIRE FABRIC (WWF), UNLESS OTHERWISE NOTED. REINFORCING STEEL TO BE WELDED SHALL CONFORM TO ASTM A706. REINFORCING STEEL SHALL BE SECURELY IED IN PLACE WITH #16 ANNEALED IRON WIRE. ALL DETAILING AND ACCESSORIES SHALL CONFORM TO ACI DETAILING MANUAL SP_66. PROVIDE CHAIRS, SPACERS, BOLSTERS, AND ITEMS IN CONTACT WITH FORMS WITH HOTJLDIP GALVANIZED' LEGS OR PLASTIC LEGS. ACCURATELY POSITION, SUPPORT, AND SECURE REINFORCEMENT AGAINST DISPLACEMENT BY FORMWORK CONSTRUCTION OR CONCRETE PLACEMENT OPERATIONS. "WET -STICKING" OF REINFORCING IS PROHIBITED. REQUIRED CONCRETE COVER FOR REINFORCING STEEL (UNLESS NOTED OTHERWISE): FOOTINGS 3" BOTTOM AND SIDES, 2" TOP SLABS 3/4" COLUMNS 1-1/2" TO TIES, 2" TOP BEAMS 1-1/2" TO STIRRUPS WALLS 1-1/2" LAP SPLICE CONTINUOUS VERTICAL OR HORIZONTAL BARS IN CONCRETE MEMBERS IN ACCORDANCE WITH ACI 318, LATEST EDITION, FOR CLASS "B" TENSION LAP SPLICES. DO NOT PLICE CONTINUOUS TOP BARS IN BEAMS AT ENDS OF CLEAR SPANS. DO NOT SPLICE CONTINUOUS BOTTOM BARS N BEAMS IN CLEAR SPANS BETWEEN SUPPORTS. SHOW ALL SPLICES ON SHOP DRAWINGS. SPLICE LOCATI NS AND METHODS SUBJECT TO APPROVAL OF STRUCTURAL ENGINEER. AT SLAB AND WALL OPENINGS PROVIDE A MINIMUM OF (2) #5 BARS ALL FOUR SIDES AND DIAGONALLY; EXTEND THESE BARS A LAP DISTANCE OR A MINIMUM OF 24" PAST THE OPENING OR HOOK BARS IF DISCONTINUOUS. DOWEL ALL WALLS AND COLUMNS TO FOOTINGS WITH BAR SIZE AND SPACING TO MATCH VERTICAL REINFORCING UNLESS OTHERWISE SHOWN. MASONRY WALLS: MASONRY UNITS SHALL MEET ASTM C90, TYPE 2. ASSEMBLIES SHALL N AVE A MINIMUM COMPRESSIVE STRENGTH OF fm= 1500. MORTAR SHALL BE TYPE "M" OR "S" AND MEET ASTM C270. GROUT SHALL BE 2000 PSI MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS IN ACCORDANCE WITH ASTM C476. GROUT SHALL CONSIST OF A MIXTURE OF CEMENTITIOUS MATERIALS AND AGGREGATE TO WHICH SUFFICIENT WATER HAS BEEN ADDED TO CAUSE THE MIXTURE TO FLOW WITHOUT SEGREGATION OF THE CONSTITUENTS. GROUT SHALL HAVE A MAX. COURSE AGGR. SIZE OF e" & SHALL BE PLACE WITH A SLUMP OF 8 TO 11 INCHES. ALL CELLS CONTAINING VERTICAL BARS, BOND BEAMS, AND ALL CELLS BELOW GRADE SHALL BE FILLED WITH GROUT. MAXIMUM HEIGHT OF GROUT POUR ALLOWED IS 5'-0" UNLESS CLEAN-OUT OPENING IS PROVIDED AT BOTT M OF CELLS TO BE FILLED. LOCATE CLEAN-OUT OPENINGS IN AREAS NOT EXPOSED TO VIEW. CLEAN OUT PENINGS SHALL HAVE A MIN, OPENING DIMENSION OF 3 INCHES. UNLESS NOTED OTHERWISE EIGHT INCH MASONRY WALLS SHALL BERTIALLY REINFORCED MASONRY WALL CONSTRUCTION WITH #5 AT 48 INCH O.C. IN GROUT FILLED CELLS. AD (1) #5 REINFORCING BAR EACH SIDE OF OPENINGS EXCEEDING 3 FEET. PROVIDE REINFORCING BARS AT CORNERS, INTERSECTIONS, AND EACH SIDE OF OPENINGS. PROVIDE (2) REINFORCING BARS EACH SIDE OF OPENINGS OVER 4 FEET WIDE, AND AS SHOWN ON THE PLANS. PROVIDE HOOKED DOWELS INTO FOOTINGS AND STRUCTURE ABOVE AND/ORB LOW TO PROVIDE CONTINUITY. PROVIDE 9 GAGE GALVANIZED HORIZONTAL JOINT REINFORCING (DUR-O-WAL OR ENGINEER -APPROVED EQUAL) AT 16" O.C. DO NOT PLACE CONDUITS, PIPES, ETC., IN CELLS WITH VERTICAL REIN ORCING. DO NOT RUN CONDUITS, PIPES, ETC., HORIZONTALLY IN CMU WALLS PARALLEL TO LENGTH OF WALL. ERE MASONRY WALLS ABUT CONCRETE COLUMNS TO BE PLACED PRIOR TO ERECTION OF MASONRY WALLS, PtOVIDE DOVETAIL SLOTS BETWEEN COLUMN AND WALLS AND GROUT THE CMU CELL CONTAINING THE DOVETAIL A �CHOIRS. OTHERWISE, EXTEND CMU HORIZONTAL JOINT REINFORCING THROUGH CONCRETE COLUMN. CONTROL JOINTS SHALL BE PROVIDED IN ALL CONCRETE MASONRY CONSTRUCTION AT LOCATIONS INDICATED ON THE ARCHITECTURAL DRAWINGS. HORIZONTAL WALL REINFORCING SHALL BE STOPPED EACH SIDE OF CONTROL JOINTS. SEE ARCHITECTURAL DRAWINGS FOR SEALANT REQUIREMENTS AT CONTROL JOINTS. USE METAL LATH OR WIRE SCREEN FOR CAVITY CAPS. SHEET METAL, FELT, BUILDING PAPER, OR LIKE MATERIALS ARE PROHIBITED. CbIFMlrAI- AnHEsiVF ANCHORING IN HOLLOW;CELL APPLICATIONS ADHESIVE ANCHORS (EPDXY STYLE) SHALL BE USED IN HOLLOW CMU APPLICATIONS FOR STRUCTURAL ANCHORING. ANCHORS SHALL BE TESTED TO ASTM E488 AND ICBO AC 8. ICBO AND/OR SBCCI CODE COMPLIANCE IS REQUIRED IN APPROPRIATE AREAS, METRO-DADE COMPLIANCE AN /OR FLORIDA BUILDING CODE COMPLIANCE ARE REQUIRED IN FLORIDA. ANCHORING SYSTEM SHALL INCLUDE THE ADHESIVE, MESH SCREEN (OR UMBRELLA), ANCHOR (OR INSERT) AND WASHER/NUT FOR PROPER ANCHORING. ACCEPTED PRODUCTS ARE ITW RED HEAD ACRYLIC 7, GRANITE 5 OR ENGINEER APPROVED SUBSTITUTION. ADHESIVE SHALL BE MOISTURE INSENSITIVE (ALLOWING INSTALLATIONS IN DAMP OR WATER -FILLED HOLES). ADHESIVE SHALL HAVE A FULL -CURE LOAD OF 2 HOURS OR LESS AT 7P°F OR SAFETY ISSUES. MESH SCREENS SHALL BE FORMED INTO A CYLINDRICAL SHAPE WITH NE END CLOSED. ALTERNATELY, UMBRELLA SUPPLIED BY ITW RED HEAD MAY BE USED IN APPROPRIAT APPLICATIONS. THREADED STUDS SHALL CONFORM TO ASTM A36 (STANDARD CARBON STEEL) UNLESS NOTED THERWISE. PERMANENTLY EXPOSED STUDS SHALL BE STAINLESS STEEL. NUTS AND WASHERS SHALL CON ORM TO THE SAME SPECIFICATION AS THE SUPPLIED STUD. INSTALLATION SHALL BE IN CONFORMANCE WITH MANUFACTURER'S POINTED LITERATURE. INSTALLATION SHALL ALSO INCLUDE BRUSHING AND CLEANING OF DRILLED HOLES WITH COMPRESSED AIR AS INSTRUCTED. INSTALLERS SHALL BE TRAINED BY THE MANUFACTURER'S REPRESENTATIVE. EMBEDMENT SHALL BE AS INDICATED ON THE STRUCTURAL DRAWINGS. DESIGN CRITERIA: DESIGN WAS BASED ON STRENGTH AND DEFLECTION CRITERIA OF THE 2017 FLORIDA BUILDING CODE 6TH EDITION. IN ADDITION TO THE DEAD LOADS, THE FOLLOWING LOADS AND ALLOWABLES WERE USED FOR DESIGN, WITH LIVE LOADS REDUCED PER THE 2017 FBC: a a a m T� DEFLECTION 0240 - L/180 L/360 - L/240 0360 -L1240 U240 - BRITTLE U180 - FLEXIBLE WIND PRESSURES ON WALLS & ROOFS 3 EFFECTIVE AREA OF OPENING/ROOF ZONE LIVE LOAD DEAD LOAD ROOF: 20 PSF 15 PSF FLOORS: 40 PSF 15 PSF DECKS: 50 PSF 15 PSF WALLS: PER C&C PER ASCE7-10 42.6 BELOW TBLE. C3-1 ULTIMATE WIND SPEED 10.1 to 20 130 MPH PER ASCE 7-10 NOMINAL WIND SPEED: 22.4 101MPH PER FBC R301.2.1.3 EXPOSURE -93.8 C PER ASCE 7-10 IMPORTANCE FACTOR 40.6 1.0 CATEGORY II INTERNAL PRESSURE COEFF +/-0.18 ENCLOSED (PROTECTED OPENINGS) COMPONENTS & CLADDING PRESSURES PER TABLE & CHARTS ON THIS PAGE. a a a m T� DEFLECTION 0240 - L/180 L/360 - L/240 0360 -L1240 U240 - BRITTLE U180 - FLEXIBLE WIND PRESSURES ON WALLS & ROOFS 3 EFFECTIVE AREA OF OPENING/ROOF ZONE ROOF ZONES' EXTERIOR WALLS' INTERIOR ZONE 1 EDGE ZONE 2 CORNER ZONE 3 INTERIOR ZONE 4 END ZONE 5 0 to 10 24.5 -38.9 24.5 -67.8 24.5 -100.2 42.6 -46.2 42.6 -57.0 10.1 to 20 22.4 -37.8 22.4 -62.4 22.4 -93.8 40.6 -44.2 40.6 -53.2 20.1 to 50 19.5 -36.4 19.5 -55.2 19.5 -85.1 38.1 -41.7 38.1 -48.0 50.1 to 100 17.4 -35.3 17.4 -49.8 17.4 1 -73.1 36.3 1 -39.8 36.3 -44.2 100.1 to 500 - - - - - - 31.8 -35.3 31.8 -35.3 1. WIND PRESSURES SHOWN ABOVE ARE FOR STRUCTURES WITH A MEAN ROOF HEIGHT OF 30 FEET OR LESS WITH A ROOF PITCH BETWEEN 2/12 & 6/12 (VERT./HORIZ.). IF THE STRUCTURE IS OUTSIDE THESE PARAMETER PLEASE CONTACT THE ENGINEER. 2. THE EFFECTIVE AREA IS EQUAL TO THE LENGTH " WIDTH OF THE PROPOSED OPENING OR SPAN. THE WIDTH SHALL BE PERMITTED TO BE NOT LESS THAN 3 OF THE SPAN LENGTH. THE EFFECTIVE AREA FOR FASTENERS SHALL NOT BE GREATER THAN THE TRIBUTARY AREA B/T FASTENERS. 3. ALL WIND PRESSURE VALUES IN POUNDS; PER SQ. FT(PSF) & ARE CONSIDERED ULTIMATE VALUES. MULTIPLY VALUES BY 0.6 FOR NOMINAL PRESSURES PER FBC R301.2.1.6 ZONE CHARTS Tia ------------------1 �-• --' m k lj T I� -I---------02--------- 3 031 U -1---------- 21 Im 3�------- 2 I� 0 GABLE ROOFS a a a PSF POUNDS PER SQUARE FEET PSI POUNDS PER SQUARE INCH SS STAINLESS STEEL STAGG. STAGGERED SPF SPRUCE -PINE -FIR SYP SOUTHERN YELLOW PINE (No. 2 MIN.) SW SHEAR WALL T/G TOGETHER T&G TONGUE AND GROOVE Typ TYPICAL U.N.O. UNLESS OTHERWISE NOTED W/ WITH w/o WITHOUT W.W.M/F WELDED WIRE MESH OR FABRIC --*/ --G-- WALLS SHEETINDEX SN -1 STRUCTURAL NOTES & SPECIFICATIONS S-1 - FOUNDATION PLAN & DETAILS S-2 FRAMING PLANS S-3 ROOF FRAMING PLANS & DETAILS S_4 FRAMING DETAILS SYMBOL LEGEND VIEW DIRECTION DETAIUSECTION NUMBER WALL SECTION 1 S LOCATION OF SECTION CUT N SHEET No. WHERE SECTION IS LOCATED. �•: V DETAIUSECTION NUMBER ELEVATION 1 S- VIEW DIRECTION SHEET No. WHERE oN >M SECTION IS LOCATED. 0., DETAIUSECTION NUMBER DETAIL 1 S-1 SHEET No. WHERE C4,4 SECTION IS LOCATED. CALL OUT [A] N CUT/ MATCH LINE y ELEVATION DATUM NM SLAB STEP X ?p/Tll (INCHES) I-_ cd D C z Z J W017 � �U OQ w >. w00 w� = Z (n O J N F-- 00 Q r • .�110 N LA �•: V oN >M 0., am Ln � C4,4 L u Vui U. N Lll NM z :z o ._.a z V.�.. oC N ^ .. M IRV ■ rm. 0. own, PROSECT #: 18-305 DESIGNED: KCM DRAWN: KCM SCALE: AS NOTED ISSUED: 8/16/18 REVISION -1: REVISION -2: le o 803 • P e� STATE OF O sl 1B1®®een`100 :VIN C. MARTIN, PE #803 SHEET SN -1 U w O r U - w Lu > z O N 0 z U - z O z O Z Lu 0 z w > Lu V) V) Z Q Lu J Q V) 0 z 0 J J z Lu w z z Lu Z f= w w U - z Lu V) z 0 z U-1 EL F- 0 a W_w ON W ca O0 oQ OZ >- O z ,- Qo Z z 0 a_0 De ON 60 =N 3w z� U -J Q r)>_ � w w> w0' w Z OQ ujU N W =) 2 wcaU F— J Oa zN J w a =O NU �2Q Lou- � z Zo OU U Lii zQ 0::� V) X uiw 0 C QCLQ ,1 0 Qw Cew w V) Q �O zU w Lu �Q 3 z ZO z QLu � 0 t� Uuj J W J W z ZZ �w wW W z� W3: z� ._. z �-o QN �z � W 00 20'-3" C.L. POST 13'-10" L S-1 4'-0" SW16 • A I I 1I 1 I i Sw161 I I 2 I • I TE8 1 S-1 S-1 I B I I I SW16----SW16 ----J 1 • ------------- I 1 �N (--------------- –N F.F.E. O' -0"m I IF24 1 F_ — — — — — — — ------ --i • I IF24 I ------------ --1 L_1 r i A ALL SLABS: I Ah 47 SW16 I• I C ( I MA12 4 DEEP POURED CONC. SLAB 3 I I I 1 I I w/ 6x6, #10/10 WW, F. OR �n I I S-1 FIBERMESH REINF. OVER 6 MIL S-1 o� 1-1 VAPOR BARRIER OVER CLEAN F. F.E. 0'-0" F- -I COMPACTED FILL. TE8 I 1 IF24 I • I IF24 J L — I-� 0'-0" FIN. FLR. ELEV. (ASSUMED DATUM) 3. B 1 20'-84 _ C.L. 17-44 I SW16 1• I -^�' AL MA12 I I 1 I I 1 I I TE8 L——L 1------------- ZZ — - - — —SW16 • • • r SW16 - 4 S-1 r- 6'-0" 20'-6" CONTRACTOR SHALL VERIFY ALL DIMENSIONS WITH THE APPROVED ARCHITECTURAL PLANS, SITE PLAN, AND EXISTING CONDITIONS BEFORE PLACEMENT OF CONCRETE. 10'-0" — M12 — — — — — — — o I-----------1 I ALL SLABS: 4" DEEP POURED CONC. SLAB I M12 o M12 w/ 6x6, #10/10 W.W.F. OR o I FIBERMESH REINF. OVER 6 MIL I o 0 VAPOR BARRIER OVER CLEAN I COMPACTED FILL. { I L — — — — — — — —- —� M12 I rE8 TE81 9 — — TE8 — J 10'-0" 0 5 S-1 S-1 FOUNDATION PLAN -GARAGE 7'-3" 17'-7" FOUNDATION PLAN -ADDITION scnLe: 1/4" rn. ALIGN w/ EXISTING — — SW16 — — TE8 4 S-1 T'L_ TE8 _ IF18 FTG. TO BE PLACED UNDER EXIST. BEAM BEARING LOCATION I I MA12 I I LJ_. 1 2" RECESS (CMU ONLY) INSTALL TRANSFER BARS PER PLANS (CMU WALLS ONLY) VAPOR BARRIER (6 -MIL MIN.) OVER CLEAN COMPACTED FILL SCHEDULE CMU HEADER BLOCK w/ (1) #5 BAR CONTINUOUS 8"x16" CMU STEMWALL. FILL REINFORCED CELLS SOLID ADD (1) #4 MIN. IN --� FOOTING FOR BRICK ' 1 LEDGE \ ZX 0 z W SW16 Z J Q 4" CONCRETE SLAB W/ 6X6 W1.4xl .4 OR FIBERMESH z GRADEOD � r�\ r 6" OPT. BRICK LEDGE w/ (1) #4 OR #5 BAR FROM GRADE TO BOT. OF 14 i FOOTING. SEE PLAN FOR LOCATIONS. MONOLITHIC FOOTING, SEE —� FOOTING SCHEDULE FOR SIZE & REINFORCING \� EXTERIOR MONOLITHIC FOOTING 4" CONCRETE SLAB W/ 6X6 W1.4xl .4 OR FIBERMESH OVER 6 MIL VAPOR BARRIER & CLEAN COMPACT FILL VERTICAL REINFORCING TO BE (1) #5 AT 48" O.C. & AT CORNERS w/ MIN. 7" BEND AT BOTTOM & 12" MIN. BEND INTO SLAB, U.N.O. STEMWALL FOOTING. SEE SCHEDULE FOR SIZE AND REINFORCING. BEARING SOILS TO BE COMPACTED & FREE OF DELETERIOUS MATERIALS STEMWALL FO2T'NG NOTE: CONTACT ENGINEF STEMWALL EXCEEDS 48", FROM T.O.S TO FOOTER (6 COURSES). PLACE (1) #5 VERTICAL BAR AT THRU PAD w/ 12" HOOK POST w/ HOLDOWN. SEE FRAMING PLANS & DETAILS FOR SPECS. a ..d. �z \`\ � ' ��- n • \\ bo .� INTO SLAB & 7" INTO FTG. SEE TYP. STEMWALL DETAIL 18"x18" PAD FOOTING FOR FOR ALL OTHER SPECS. PORCH POST SUPPORT. GRADE �, \\\\\ \\\� PLACE (2) #5 BARS EACH WAY 44 SEE TYP. STEMWALL \/ w ° \\� DETAIL & SCHEDULE FOR SIZE &REINFORCING \ SEE FOOTING SCHEDULE \ / 2 STEMWALL FTG. & PAD NOTE: CONTACT ENGINEER IF STEMWALL EXCEEDS 48", FROM T.O.S TO FOOTER (6 COURSES). 4" CONCRETE SLAB W/ 6X6 W1.4xl .4 OR FIBERMESH. F.F.E. VAPOR BARRIER (6 -MIL MIN.) OVER CLEAN /\ \/\ sr 0 1 \ \\ COMPACTED FILL SCHEDULE INTERIOR MONOLITHIC FOOTING. SEE FOOTING SCHEDULE FOR SIZE AND REINFORCING INTERIOR MONOLITHIC FOOTING THICKENED EDGE SLAB, SEE FOOTING SCHEDULE FOR SIZE & REINFORCING 4" CONCRETE SLAB W/ 6X6 W1.4x1.4 OR FIBERMESH /\\ �\ /\ VAPOR BARRIER (6 -MIL MIN.) OVER CLEAN SEE FOOTING COMPACTED FILL SCHUDLE 4 THICKENED EDGE SLAB Lu Q O 0 z FOUNDATION LEGEND FOUNDATION SCHEDULE::77 ■ ❑ VERTICAL REINFORCEMENT DRILL & EPDXY (2) #5 BA FROM NEW FTG. IT EXI -SPE MIN. EMBED REINFORCING Ln -SPE WIDTH LENG. THICKNESS 8" CMU STEMWALL B [] oN >M MARK SLAB BOTTOM TOP TRANSVERSE FOOTINGS MA12 11-0 " CONT. 1' - 0" (2) #5 CONTINUOUS N/A N/A INTERIOR MONOLITHIC ALL EXTERIOR ISOLATE 1'- 4" CONT. 10" (2) #5 CONTINUOUS N/A N/A EXTERIOR STEMWALL SW16 IF18 V-6' l' - 6" 11-01. 2 #5 EACH WAY N/A N/A ISOLATED FOOTING IF24 2'-0" 2'-0' 1' - 0" (2) #5 EACH WAY N/A N/A ISOLATED FOOTING TES 8" CONT. 1' - 0" 1) #5 CONTINUOUS N/A N/A THICKENED EDGE M12 1' - 0" CONT. 1' - 0" (2) #5 CONTINUOUS N/A N/A MONOLITHIC ALIGN w/ EXISTING — — SW16 — — TE8 4 S-1 T'L_ TE8 _ IF18 FTG. TO BE PLACED UNDER EXIST. BEAM BEARING LOCATION I I MA12 I I LJ_. 1 2" RECESS (CMU ONLY) INSTALL TRANSFER BARS PER PLANS (CMU WALLS ONLY) VAPOR BARRIER (6 -MIL MIN.) OVER CLEAN COMPACTED FILL SCHEDULE CMU HEADER BLOCK w/ (1) #5 BAR CONTINUOUS 8"x16" CMU STEMWALL. FILL REINFORCED CELLS SOLID ADD (1) #4 MIN. IN --� FOOTING FOR BRICK ' 1 LEDGE \ ZX 0 z W SW16 Z J Q 4" CONCRETE SLAB W/ 6X6 W1.4xl .4 OR FIBERMESH z GRADEOD � r�\ r 6" OPT. BRICK LEDGE w/ (1) #4 OR #5 BAR FROM GRADE TO BOT. OF 14 i FOOTING. SEE PLAN FOR LOCATIONS. MONOLITHIC FOOTING, SEE —� FOOTING SCHEDULE FOR SIZE & REINFORCING \� EXTERIOR MONOLITHIC FOOTING 4" CONCRETE SLAB W/ 6X6 W1.4xl .4 OR FIBERMESH OVER 6 MIL VAPOR BARRIER & CLEAN COMPACT FILL VERTICAL REINFORCING TO BE (1) #5 AT 48" O.C. & AT CORNERS w/ MIN. 7" BEND AT BOTTOM & 12" MIN. BEND INTO SLAB, U.N.O. STEMWALL FOOTING. SEE SCHEDULE FOR SIZE AND REINFORCING. BEARING SOILS TO BE COMPACTED & FREE OF DELETERIOUS MATERIALS STEMWALL FO2T'NG NOTE: CONTACT ENGINEF STEMWALL EXCEEDS 48", FROM T.O.S TO FOOTER (6 COURSES). PLACE (1) #5 VERTICAL BAR AT THRU PAD w/ 12" HOOK POST w/ HOLDOWN. SEE FRAMING PLANS & DETAILS FOR SPECS. a ..d. �z \`\ � ' ��- n • \\ bo .� INTO SLAB & 7" INTO FTG. SEE TYP. STEMWALL DETAIL 18"x18" PAD FOOTING FOR FOR ALL OTHER SPECS. PORCH POST SUPPORT. GRADE �, \\\\\ \\\� PLACE (2) #5 BARS EACH WAY 44 SEE TYP. STEMWALL \/ w ° \\� DETAIL & SCHEDULE FOR SIZE &REINFORCING \ SEE FOOTING SCHEDULE \ / 2 STEMWALL FTG. & PAD NOTE: CONTACT ENGINEER IF STEMWALL EXCEEDS 48", FROM T.O.S TO FOOTER (6 COURSES). 4" CONCRETE SLAB W/ 6X6 W1.4xl .4 OR FIBERMESH. F.F.E. VAPOR BARRIER (6 -MIL MIN.) OVER CLEAN /\ \/\ sr 0 1 \ \\ COMPACTED FILL SCHEDULE INTERIOR MONOLITHIC FOOTING. SEE FOOTING SCHEDULE FOR SIZE AND REINFORCING INTERIOR MONOLITHIC FOOTING THICKENED EDGE SLAB, SEE FOOTING SCHEDULE FOR SIZE & REINFORCING 4" CONCRETE SLAB W/ 6X6 W1.4x1.4 OR FIBERMESH /\\ �\ /\ VAPOR BARRIER (6 -MIL MIN.) OVER CLEAN SEE FOOTING COMPACTED FILL SCHUDLE 4 THICKENED EDGE SLAB Lu Q O 0 z FOUNDATION LEGEND ■ ❑ VERTICAL REINFORCEMENT DRILL & EPDXY (2) #5 BA FROM NEW FTG. IT EXI 2S, 16" LG T. FTG, 6" MIN. EMBED N Ln V (1) #5 BAR, 16" LG., AT 36' O.C. DRILL & 8" CMU STEMWALL B [] oN >M EPDXY MIN. 6" INTO EXIST. SLAB PLACE (1) #5 VERTICAL oN FOOTINGS U� REINFORCEMENT IN STE WALL ABOVE Lu ALL EXTERIOR ISOLATE FOOTINGS z (IF24). CENTER ABOVE F G. ALIGN w/ EXISTING — — SW16 — — TE8 4 S-1 T'L_ TE8 _ IF18 FTG. TO BE PLACED UNDER EXIST. BEAM BEARING LOCATION I I MA12 I I LJ_. 1 2" RECESS (CMU ONLY) INSTALL TRANSFER BARS PER PLANS (CMU WALLS ONLY) VAPOR BARRIER (6 -MIL MIN.) OVER CLEAN COMPACTED FILL SCHEDULE CMU HEADER BLOCK w/ (1) #5 BAR CONTINUOUS 8"x16" CMU STEMWALL. FILL REINFORCED CELLS SOLID ADD (1) #4 MIN. IN --� FOOTING FOR BRICK ' 1 LEDGE \ ZX 0 z W SW16 Z J Q 4" CONCRETE SLAB W/ 6X6 W1.4xl .4 OR FIBERMESH z GRADEOD � r�\ r 6" OPT. BRICK LEDGE w/ (1) #4 OR #5 BAR FROM GRADE TO BOT. OF 14 i FOOTING. SEE PLAN FOR LOCATIONS. MONOLITHIC FOOTING, SEE —� FOOTING SCHEDULE FOR SIZE & REINFORCING \� EXTERIOR MONOLITHIC FOOTING 4" CONCRETE SLAB W/ 6X6 W1.4xl .4 OR FIBERMESH OVER 6 MIL VAPOR BARRIER & CLEAN COMPACT FILL VERTICAL REINFORCING TO BE (1) #5 AT 48" O.C. & AT CORNERS w/ MIN. 7" BEND AT BOTTOM & 12" MIN. BEND INTO SLAB, U.N.O. STEMWALL FOOTING. SEE SCHEDULE FOR SIZE AND REINFORCING. BEARING SOILS TO BE COMPACTED & FREE OF DELETERIOUS MATERIALS STEMWALL FO2T'NG NOTE: CONTACT ENGINEF STEMWALL EXCEEDS 48", FROM T.O.S TO FOOTER (6 COURSES). PLACE (1) #5 VERTICAL BAR AT THRU PAD w/ 12" HOOK POST w/ HOLDOWN. SEE FRAMING PLANS & DETAILS FOR SPECS. a ..d. �z \`\ � ' ��- n • \\ bo .� INTO SLAB & 7" INTO FTG. SEE TYP. STEMWALL DETAIL 18"x18" PAD FOOTING FOR FOR ALL OTHER SPECS. PORCH POST SUPPORT. GRADE �, \\\\\ \\\� PLACE (2) #5 BARS EACH WAY 44 SEE TYP. STEMWALL \/ w ° \\� DETAIL & SCHEDULE FOR SIZE &REINFORCING \ SEE FOOTING SCHEDULE \ / 2 STEMWALL FTG. & PAD NOTE: CONTACT ENGINEER IF STEMWALL EXCEEDS 48", FROM T.O.S TO FOOTER (6 COURSES). 4" CONCRETE SLAB W/ 6X6 W1.4xl .4 OR FIBERMESH. F.F.E. VAPOR BARRIER (6 -MIL MIN.) OVER CLEAN /\ \/\ sr 0 1 \ \\ COMPACTED FILL SCHEDULE INTERIOR MONOLITHIC FOOTING. SEE FOOTING SCHEDULE FOR SIZE AND REINFORCING INTERIOR MONOLITHIC FOOTING THICKENED EDGE SLAB, SEE FOOTING SCHEDULE FOR SIZE & REINFORCING 4" CONCRETE SLAB W/ 6X6 W1.4x1.4 OR FIBERMESH /\\ �\ /\ VAPOR BARRIER (6 -MIL MIN.) OVER CLEAN SEE FOOTING COMPACTED FILL SCHUDLE 4 THICKENED EDGE SLAB Lu Q O 0 z PRO) ECT #: 18-305 DESIGNED: KCM DRAWN: KCM SCALE: AS NOTED ISSUED: 8/16/18 REVISION -1: REVISION -2: '��s�N C. ♦ I 035 ' -�3 �. TAT O F � o O R 'e,°®SS eO N A `'(l_ 0®® KEVIN C. MARTIN, PE #80359 SHEET S-1 �'O N Ln V Z oN >M mu" oN U� r -- Lu NM z ;z� ..-. Q "1 > �,,� • z O O°` L.L.. z .�.. M I� Ah Q low PRO) ECT #: 18-305 DESIGNED: KCM DRAWN: KCM SCALE: AS NOTED ISSUED: 8/16/18 REVISION -1: REVISION -2: '��s�N C. ♦ I 035 ' -�3 �. TAT O F � o O R 'e,°®SS eO N A `'(l_ 0®® KEVIN C. MARTIN, PE #80359 SHEET S-1 U w 0 r U- ry Lu > z O V) O z U- -7 Z 0 V) z 0 z Lu 0 Z Lu > w V) Z Q Lu Q V) O Z r) J J Z w Lu Z Z Lu z Q 0 Ix LL Z Lu V) z 0 U Z w K 0 w CL 0 Q uj - u -V) 00 �Q OZ r0 z ,- Qp zZ rzO Q� CZ ceQ ON J LU Z 00 = z Lu Z� _o uj J UQ 0} wLL_ w w> cep w OQ Lu U �_ Lu (� m J F_ J 0= Z N J � Q� U Va 0Q� Lu '-- U -7 z L O U u. za Lu �ry Da Za Qa Q u wuu wC z( Lu Gc 3� vi ` Z� <i U� J L J L z Fi Lu w� Zi zl w z P= Q O i ) i LJ u u u L > > n 7 n Z u (2) 2x10 No. 2 SYP B D uj L) O 9N zQ 5 O S-4 Q m (2) 2x8 2:2 6X6 No. 2 SYP PORCH POSTS,TYP. (2) 2.0E 1.75"x9.25" GP LVL 2.0E 1.75"x11 7/8" GP LVL ICI 1 S-4 Ila (2) 2x8 2:2 ICI C (2) 2x10 No. 2 6X6 No. 2 SYP PORCH POSTS,TYP. 3 S-4 (2) 2x10 No. 2 SYP ( (2) 2x8 2:2 16, (2) 2x6 2:1 W o 00 (V N 0 v Ile r2.OE REMOVE EXIST. FLOOR JOIST INSTALL NEW 14" TJ 360 I -JOISTS AT 24" O.C. FULL SPAN a. � N 6 z 9.25" GP LVL cx 2 C kc 1 ) 2x8 2:1 ** EXISTING / FLOOR JOIST DIRECTION (2 227 2x8 (2) 2x6 2:1 GARAGE Ff�AMING SCALE: 1/4" = l'-0" (2) 2x6 2:1 1 S-2 U) u� m 00 o x tV N N 0 v PLAN IFI ** EXISTING �- FLOOR JOIST --> DIRECTION FILL IN FRAMING PER TYP. WALL SECTIONS (2) 2x8 2 2:1 S-4 0 �--- PLACE 3 -PLY STUD GROUP AT BEAM BEARING ** EXISTING �- FLOOR JOIST --� DIRECTION f 1ST FLR, FRAMING PLAN SCALE: .r<"= l' -O" ** EXISTING FLOOR JOIST DIRECTION rAPArF WAI I FRAMING. TYP. SCALE: 1/4!'= 1'-0" ** IF EXISTING FLOOR JOIST DIRECTION IS DIFFERENT THAN INDICATED ON THE PLANS CONTACT ENGINEER IMMEDIATELY** PLACE 3 -PLY No. 2 SYP STUD GROUP UNDER RIDGE BEAM a BEARING. FASTEN STUDS T/G w/ 10d NAILS AT 8" O.C. STAGG. EACH SIDE. FASTEN RIDGE BEAM TO STUD GROUP W/ (2) CS14 STRAPS EACH SIDE AND EACH END. FASTEN STUD GROUP TO FOOTING w/ (1) HTT4 HOLDOWN, USE 8" ANCHOR DRILLED & EPDXY MIN. 7" EMBED. PLACE 3 -PLY No. 2 SYP STUD GROUP UNDER BEAM BEARING. FASTEN STUDS T/G w/ 10d NAILS AT 8" O.C. STAGG. EACH a SIDE. FASTEN BEAM TO STUD GROUP W/ (2) HTS16 TWIST STRAPS EACH SIDE. FASTEN STUD GROUP TO FOOTING w/ (1) HTT4 HOEDOWN, USE 8" ANCHOR DRILLED & EPDXY MIN. 7" EMBED. INSTALL SIMPSON DTT2Z HOLDOWN AT BASE OF CORNER OR a OPENING KING STUD GROUP WHERE SHOWN. FILL ALL HOLES W1 4" x 2.5" SDS SCREWS; FASTEN TO FOUNDATION W/ 1/2" THREADED ROD SET 7" INTO ADHESIVE. 1 S-4 ALL EXTERIOR WALLS NOT LABELED AS SHEARWALLS SHALL BE CONSIDERED SHEARWALL "SW -1" AND CONSTRUCTED ACCORDING TO THE SHEARWALL LEGEND, U.N.O. PLACE DBL. STUD GROUP UNDER PORCH BEAM BEARING IN EXTERIOR WALL. NOTCH BEAM AT TOP PLATE & FASTEN STUD GROUP TO PORCH BEAM W/ (1) MSTA 18 STRAP OR LTS18 TWIST STRAP. E FASTEN END WALL STUD GROUP TO EXISTING FRAMED WALL - w/ 10d NAILS AT 6" O.C. STAGGERD VERIFY EXISTING BEAM IS MINIMUM 4 -PLY 2x12 No.2 SYP OR ❑F (2) 2.0E 1.75"x14" GP LVL. FASTEN 4 -PLY 2x12 BEAM T/G w/ 4'x4.5 SDS SCREWS AT 12" O.C. STAGG.FASTEN NEW TJI FLOOR JOISTS TO BEAM w/ ITS2.37/14 TOP FLANGE HANGERS. FILL ALL HOLES WITH 10d NAILS LVL FASTENING REQ. 2 TO 3 -PLY: (3) ROWS OF 10d NAILS AT 12" O.C. OR (2) ROWS OF 16d NAILS AT 12" O.C. EACH SIDE, 4 -PLY: (2) ROWS OF T" x 6" SDS SCREWS AT 24" O.C. EACH SIDE. STRUCTURAL SHEATHING REQUIREMENTS SHEATHING MIN. I MIN. ZONE 2 ZONE 3 CANTILEVER 4'-0" SHEATHING FIELD NAIUSPACING ROW SW -1 BEAM FOR ROOF- O.H. :NAIL: EDGE/FIELD NAIL EDGE/FIELD NAIL EDGE/FIELD SHINGLE 7/16" O.H. SUPPORT 6"/12" o.c. 8d R.S. 6"/12" o.c. 8d R.S. FASTEN BEAM TO CORNER (ROOF) OSB/PLY 2X6 SPF STUD 16„ 16 „ STUD GROUP w/ CS14 16 ,. 16 METAL 15/32"8d SEE STRAP, TYP. 8d R.S. 6"/12" o.c. Bd R.S. 6"/6" o.c. PLA SEE FRAMING PLANS & 16" ROOF & FLOOR 2X4 SPF STUD & DETA TYPICAL DETAILS FOR TILE 19/32" PLY 10d 6"/12" o.c. 8d R.S. FRAMING SPECS 8d R.S. 6"/6" o.c. (ROOF) 16" R. S. SEE PLAN FOR TYPICAL 16" 16" 2X6 SPF STUD FLOOR 23/32" T&G HOEDOWN FASTENINGS GLUED & NAILED - EDGES: 6" o.c; FIELD: 12" o.c. 16" OSB/PLY 8d R.S. PORCH ** EXISTING FLOOR JOIST DIRECTION rAPArF WAI I FRAMING. TYP. SCALE: 1/4!'= 1'-0" ** IF EXISTING FLOOR JOIST DIRECTION IS DIFFERENT THAN INDICATED ON THE PLANS CONTACT ENGINEER IMMEDIATELY** PLACE 3 -PLY No. 2 SYP STUD GROUP UNDER RIDGE BEAM a BEARING. FASTEN STUDS T/G w/ 10d NAILS AT 8" O.C. STAGG. EACH SIDE. FASTEN RIDGE BEAM TO STUD GROUP W/ (2) CS14 STRAPS EACH SIDE AND EACH END. FASTEN STUD GROUP TO FOOTING w/ (1) HTT4 HOLDOWN, USE 8" ANCHOR DRILLED & EPDXY MIN. 7" EMBED. PLACE 3 -PLY No. 2 SYP STUD GROUP UNDER BEAM BEARING. FASTEN STUDS T/G w/ 10d NAILS AT 8" O.C. STAGG. EACH a SIDE. FASTEN BEAM TO STUD GROUP W/ (2) HTS16 TWIST STRAPS EACH SIDE. FASTEN STUD GROUP TO FOOTING w/ (1) HTT4 HOEDOWN, USE 8" ANCHOR DRILLED & EPDXY MIN. 7" EMBED. INSTALL SIMPSON DTT2Z HOLDOWN AT BASE OF CORNER OR a OPENING KING STUD GROUP WHERE SHOWN. FILL ALL HOLES W1 4" x 2.5" SDS SCREWS; FASTEN TO FOUNDATION W/ 1/2" THREADED ROD SET 7" INTO ADHESIVE. 1 S-4 ALL EXTERIOR WALLS NOT LABELED AS SHEARWALLS SHALL BE CONSIDERED SHEARWALL "SW -1" AND CONSTRUCTED ACCORDING TO THE SHEARWALL LEGEND, U.N.O. PLACE DBL. STUD GROUP UNDER PORCH BEAM BEARING IN EXTERIOR WALL. NOTCH BEAM AT TOP PLATE & FASTEN STUD GROUP TO PORCH BEAM W/ (1) MSTA 18 STRAP OR LTS18 TWIST STRAP. E FASTEN END WALL STUD GROUP TO EXISTING FRAMED WALL - w/ 10d NAILS AT 6" O.C. STAGGERD VERIFY EXISTING BEAM IS MINIMUM 4 -PLY 2x12 No.2 SYP OR ❑F (2) 2.0E 1.75"x14" GP LVL. FASTEN 4 -PLY 2x12 BEAM T/G w/ 4'x4.5 SDS SCREWS AT 12" O.C. STAGG.FASTEN NEW TJI FLOOR JOISTS TO BEAM w/ ITS2.37/14 TOP FLANGE HANGERS. FILL ALL HOLES WITH 10d NAILS LVL FASTENING REQ. 2 TO 3 -PLY: (3) ROWS OF 10d NAILS AT 12" O.C. OR (2) ROWS OF 16d NAILS AT 12" O.C. EACH SIDE, 4 -PLY: (2) ROWS OF T" x 6" SDS SCREWS AT 24" O.C. EACH SIDE. STRUCTURAL SHEATHING REQUIREMENTS 1. ALL WOOD STRUCTURAL SHEATHING SHALL BE APA RATED, EXP05URE 1. 2. STRUCTURAL WOOD PANELS NOMINAL THICKNESS & SPAN RATINGS SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: 7/16" =.437" THICKNESS - 24/16 SPAN RATING 15/32" =.469" THICKNESS - 32/16 SPAN RATING 19/32" =.594" THICKNESS - 40/20 SPAN RATING 23/32" =.719" THICKNESS - 48/24 SPAN RATING 3. ALL ROOF SHEATHING SHALL BE INSTALLED WITH THE LONG DIMENSION PERPENDICULAR TO THE ROOF SUPPORTS. 4. SHEATHING/SUBSTRATES & FASTENINGS FOR EACH ROOFING TYPE SHALL BE IN ACCORDANCE w/ THE FLORIDA PRODUCT APPROVAL. 5. ALL NAILS SHALL BE RING SHANK NAILS U.N.O. 6. 2x BLOCKING SHALL BE USED IN ROOF ZONES 2 & 3 FOR ALL EDGE SHEATHING FASTENING. SHEAR WALL LEGEND ID SHEATHING ZONE 1 ZONE 2 ZONE 3 TYPE SHEATHING FIELD NAIUSPACING ROW SW -1 7/16" :NAIL: EDGE/FIELD NAIL EDGE/FIELD NAIL EDGE/FIELD SHINGLE 7/16" 8d R.S. 6"/12" o.c. 8d R.S. 6"/12" o.c. 8d R.S. 6"/6" o.c. (ROOF) OSB/PLY 2X6 SPF STUD 16„ 16 „ 16 „ 16 ,. 16 METAL 15/32"8d R.S. 6"/12" O.C. 8d R.S. 6"/12" o.c. Bd R.S. 6"/6" o.c. (ROOF) OSB/PLY 16" ROOF & FLOOR 2X4 SPF STUD 16" 12" TILE 19/32" PLY 10d 6"/12" o.c. 8d R.S. 6"/12" o.c. 8d R.S. 6"/6" o.c. (ROOF) 16" R. S. 16" 16" 16" 2X6 SPF STUD FLOOR 23/32" T&G 10d OR GLUED & NAILED - EDGES: 6" o.c; FIELD: 12" o.c. 16" OSB/PLY 8d R.S. PORCH 3/8" 8d EDGES: 3" o.c; FIELD: 6" o.c. CEILINGS OSB/PLY 24"* 16" WALLS 7/16"(MIN.) SEE SHEAR WALL LEDGED V OSB/PLY 1. ALL WOOD STRUCTURAL SHEATHING SHALL BE APA RATED, EXP05URE 1. 2. STRUCTURAL WOOD PANELS NOMINAL THICKNESS & SPAN RATINGS SHALL MEET THE FOLLOWING MINIMUM REQUIREMENTS: 7/16" =.437" THICKNESS - 24/16 SPAN RATING 15/32" =.469" THICKNESS - 32/16 SPAN RATING 19/32" =.594" THICKNESS - 40/20 SPAN RATING 23/32" =.719" THICKNESS - 48/24 SPAN RATING 3. ALL ROOF SHEATHING SHALL BE INSTALLED WITH THE LONG DIMENSION PERPENDICULAR TO THE ROOF SUPPORTS. 4. SHEATHING/SUBSTRATES & FASTENINGS FOR EACH ROOFING TYPE SHALL BE IN ACCORDANCE w/ THE FLORIDA PRODUCT APPROVAL. 5. ALL NAILS SHALL BE RING SHANK NAILS U.N.O. 6. 2x BLOCKING SHALL BE USED IN ROOF ZONES 2 & 3 FOR ALL EDGE SHEATHING FASTENING. SHEAR WALL LEGEND ID SHEATHING FASTENINGSILLS ANCHORS END STUD GROUPS VERTICAL EDGES HORIZONTAL EDGES FIELD NAIUSPACING ROW SW -1 7/16" 8d AT 6" 8d AT 3" SINGLE 8d AT 12" 32" O.C. 2 1. ALL SHEATHING MUST BE MINIMUM OF 16' RATED OSB OR PLYWOOD & FASTENED PER THE TYPICAL DETAILS. 2. ALL WALL SHEATHING SHALL BE FULL HEIGHT SHEATHING THAT EXTENDS FROM THE BOTTOM PLATE TO THE UPPER MOST STUD IN THE DBL. TOP PLATE. 3. SHEATHING MAY BE INSTALLED HORIZONTALLY OR VERTICALLY. ALL HORIZONTAL EDGES MUST BE FULLY BLOCKED w/ 2x FRAMING LAID FLAT AGAINST BACK SIDE OF SHEATHING FOR NAILING. 4. A MINIMUM GAP OF a" AT SHEATHING JOINTS MUST BE MAINTAINED. 5. HOLDOWNS MUST BE PLACED AT EACH END OF SHEARWALL, U.N.O. SEE FRAMING PLAN/DETAILS FOR HOLDOWNS TYPES, LOCATIONS, & INSTALLATION SPECS. 6. ALL SILL ANCHORS SHALL BE A MIN. OF �' IN DIA. w/ 3"x3")4'SQUARE WASHER & NUT EDGE OF WASHER SHALL EXTEND TO WITHIN 1/2" OF THE EDGE OF THE SILL PLATE ON THE SHEATHED SIDE. SILL ANCHORS NOT REQ. FOR UPPER LEVEL WALLS. FASTEN BTM. PLATES TO FLOOR FRAMING PER TYPICAL WALL SECTIONS. SEE DETAILS FOR INSTALLATION SPECS. 7. EXTERIOR STUCCO FINISH REQUIRES A MIN. 15/32" RATED SHEATHING INSTALLED HORIZONTALLY w/ 2x FLAT WISE BLOCKED EDGES. 8. MINIMUM END STUDS FOR EACH SHEAR WALL SECTION ARE SHOWN IN TABLE ABO AND SHALL BE CONSTRUCTED PER THE TYPICAL CORNER FRAMING DETAIL. 9. SHEARWALL FASTENING SHOULD BE CONSTRUCTED PER THE TYPICAL SHEATHING FASTENING DETAILS AND NOTES. BEARING WALL STUD SPACING ;'t LOAD BEARINGS STUDS SUPPORTING TYPE WALL HEIGHT (STUCCO FINISH) WALL HEIGHT (FLEXIBLE FINISH) 8' 9' 10' 12' 8' 9' 10' ROOF ONLY 2X4 SPF STUD 16" 16" 12" - 16" 16" 16" 10d RINGSHANK 2X4 No. 2 SPF 16" 16" 16" - 16" 16" 16" I,4% 2X6 SPF STUD 16„ 16 „ 16 „ 16 ,. 16 16 16" Ln 2X6 No. 2 SPF 24"* 24"* 16" 16" 24' 24"* 16" ROOF & FLOOR 2X4 SPF STUD 16" 12" - - 16" 12" - 2X4 No. 2 SPF 16" 16" 16" - 16" 16" 16" 2X6 SPF STUD 16" 16" 16" 16" 16" 16" 16" 2X6 No. 2 SPF 16' 16" 16" 16" 24' 24"* 16" 1. THE ABOVE STUD SPACING ARE THE MAXIMUM ALLOWABLE STUD SPACING FOR 1 REFERENCED LOADING CONDITIONS, WALL HEIGHT, EXTERIOR CLADDING TYPE, / STUD TYPE, UNLESS NOTED OTHERWISE ON THE FRAMING PLAN. 2. IF THE STUD SPACING IS NOT LISTED, THE STUD SIZE AND GRADE IS NOT ALLOWABLE FOR THE CORRESPONDING WALL HEIGHT. 3. (*) ALL WALLS WITH STUD SPACING OF 24" O.C. SHALL HAVE THE SHEATHING INSTALLED HORIZONTALLY WITH THE LONG DIMENSION PERPENDICULAR TO THE STUDS AND ALL EDGES BLOCKED w/ 2x FLAT WISE STUDS. 4. IF PROJECT HAS REQUIREMENTS OUTSIDE THE PARAMETERS OF THIS TABLE, CONTACT ENGINEER BEFORE CONSTRUCTION. FASTENER LEGEND NAIL DIAMETER LENGTH 8d COMMON 0.131" 2" 8d RINGSHANK 0.113" 28 10d x 1 12' 0.148" 1 " 10d COMMON 0.148" 3" 10d RINGSHANK 0.120" 2 a" 12d COMMON 0.148" 3" 16d COMMON 0.162" 3" v) Z z O O N G. ad N 0 0 z • V UNLESS OTHERWISE NOTED ON TH PLANS. ...� �.. 1,O PROSECT #: 18-305 OTHERWISE NOTED ON THE PLANS. 3. INSTALL THE APPROPRIATE t-11 to DESIGNED: KCM TREATED LUMBER. SEE NOTES ON V ttt N DRAWN: KCM 0 N I,4% > M 0% „J Ln N U ^ N Lu 04 V > �- • V z o av) 2 .�...Ln V Q N aM 1. ALL NAILS SHALL BE COMMON NAIL UNLESS OTHERWISE NOTED ON TH PLANS. 2. INSTALL 10d NAILS IF NOT PROSECT #: 18-305 OTHERWISE NOTED ON THE PLANS. 3. INSTALL THE APPROPRIATE FASTENERS FOR PRESSURE DESIGNED: KCM TREATED LUMBER. SEE NOTES ON SHEET S-1.0. DRAWN: KCM FRAMING LEGEND SCALE: AS NOTED STRUCTURAL BEARING WALLS ® OPENING HEADER BEAMS PORCH BEAMS & OTHERS - - EXISTING BEARING WALLS TO BE REMOVED ® POSTS/COLUMNS Q Q 1/2" THREADED ROD w/ 3"SQ. WASHER FROM DBL. TOP PLATE 1 -STORY 2 -STORY TO FTG. DRILL & EPDXY w/ MIN. 7" EMBEDMENT. No. OF PLIES SIZE OF HEADER (2) 2x QUANTITY QUANTITY OF JACK STUDS (EACH OF KING STUDS(EACH SIDE OF OPENING) SIDE OF OPENING) ISSUED: 8/16/18 REVISIONA : REVISION -2: NN ®%%0111111111141 %011as1'1se®°° C. �5o 8 3 5 -*:STATE O Fp �®e/®..�4OR\O I..; S/ A0-- 1111111101 ® ' s � KEVIN C. MARTIN, PE #80359 SHEET S-2 w — — CEILING JOISTS RIDGE BEAMS/BOARDS I 1 i i f III I ROOF FRAMING NOTES 0 U X 1. ALL ROOF FRAMING MATERIALS SHALL BE No. 2 SOUTHERN YELLOW u- � Z PINE (SYP). Cie > JOISTS FOR SKY LIGHT OR 2. ALL RAFTER, JOISTS, BEAMS, AND OTHER FRAMING MEMBER SIZES Z IF Q ARE NOTED ON THE PLANS. 3 0 ::E 3. FASTEN ROOF RAFTERS/HIPS BEAMS TO TOP PLATES OR HEADER N 3 -PLY 2x4 No. 2 SYP STUD GROUP FOR RIDGE BEAM SUPPORT. I I BEAMS W/ (1) SIMPSON SDWC15600 TRUSS SCREW OR H2.5A CLIPS. 0 RIDGE BOARD. '- H2.5A CLIPS MUST BE FASTENED ON THE EXTERIOR SIDE OF THE z Z N AND EACH END. WALL. r INSTALL (2) 2x6 No. 2 SYP HEADERS FOR RAFTER/CEILING JOIST 4. FASTEN ROOF RAFTERS TO RIDGE/HIP BEAMS AND "SLEEPERS" W/ Z Z SIMPSON A35 CLIPS, (12) 8D X1.5" NAILS, U.N.O. 0 V'5. � ADJACENT RAFTERS/CEILING JOIST SUPPORTING HEADER MUST FASTEN CEILING JOISTS TO ROOF RAFTERS AT TOP PLATE 0 INTERSECTION W/ (8) 16d NAILS AT EACH END. w 6. FASTEN COLLAR TIES TO ROOF RAFTERS w/ (8) 16d NAILS, EACH SIDE. :E O EXISTING EXTERIOR WALL COLLAR TIES SHALL NOT TO BE FASTENED HIGHER THAN 2/3 r) OVERALL ROOF RAFTER HEIGHT. Z Lu > O 7. FASTEN HIP/VALLEY ENDS TO WALL/POST W/ SIMPSON (1) HTS16 U Lu ALL HOLES w/ 10d NAILS TWIST STRAP. = SEE PLAN FOR 8. FASTEN HIPS TO RIDGE BOARD OR LEDGER W/ SIMPSON A35 CLIPS RAFTER/JOIST V..... W/ (12) 8D X1.5" NAILS. Z 3:9. �- Q FASTEN CEILING JOISTS TO OTHER INTERSECTING CEILING JOISTS a FASTEN RAFTERS 00 W/ (6) 16d TOE -NAILS & LUS28 HANGERS, U.N.O. 0 Lu 10. ALL CEILING JOISTS LAP LOCATIONS SHALL FULLY BEAR OVER AN U w/ 1/4"x3.5" SIMPSON SDS HD . INV INTERIOR BEARING WALL OR SUPPORT, TYP. SCREWS AT 16" O.C. STAGG. Z SCREWS MUST BE FASTENED z Z TO EXISTING WALL STUDS. LEGEND 0 NAILS AT EACH Z Z O J ROOF RAFTERS �-------------- COLLAR TIES Aj Z w — — CEILING JOISTS RIDGE BEAMS/BOARDS I 1 i i f III I Lu 2x6 No. 2 SYP I COLLAR TIES AT 24" X z SLEEPERS (3) 2.0E 1.75" x 11 � Z GP LVL RIDGE BEAM Lu JOISTS FOR SKY LIGHT OR O.C. 1= MULTI -PLY ROOF RAFTERS/CEILING CHIMNEY STACK PENETRATION SUPPORT. FASTEN TOGETHER W/ 10d IF Q NAILS @ 12" O.0 STAGG. FASTEN PER DETAILS & USE (1) SDWC15600 r ::E TRUSS SCREW OR H2.5A CLIP ON EACH PLY AT EXTERIOR WALLS. I I I I O 3 -PLY 2x4 No. 2 SYP STUD GROUP FOR RIDGE BEAM SUPPORT. I I H • FASTEN STUDS T/G w/ 10d NAILS AT 8" O.C. EACH SIDE. FASTEN RIDGE BOARD. '- RIDGE BEAM TO STUD GROUP W/ (2) CS14 STRAPS EACH SIDE I- 1 I I I I Z N AND EACH END. Lu z INSTALL (2) 2x6 No. 2 SYP HEADERS FOR RAFTER/CEILING JOIST ^ " OU SUPPORT AT CHIMNEY STACK & SKYLIGHTS. FASTEN HEADER TO Z FA ADJACE NT ROOF RAFTERS w/ (1) SIMSPON LUS26 HANGERS. I � ADJACENT RAFTERS/CEILING JOIST SUPPORTING HEADER MUST BE 2 -PLY. O EXISTING EXTERIOR WALL w FASTEN RAFTERSMOISTS TO O LEDGER w/ A35 CLIPS, FILL o ALL HOLES w/ 10d NAILS SEE PLAN FOR Q ;z RAFTER/JOIST V..... SIZE & SPACING. w w N �- Q FASTEN RAFTERS 00 2x8 No. 2 SYP LEDGER BOARDS TO JOISTS w/ (6) 16d FASTENED TO EXIST. FRAMING NAILS, TYP. Q w/ 1/4"x3.5" SIMPSON SDS HD . INV 0 SCREWS AT 16" O.C. STAGG. Z SCREWS MUST BE FASTENED FASCIA BOARD, Z TO EXISTING WALL STUDS. FASTEN (2) 16d END a 0 NAILS AT EACH Z Z O RAFTER. SEE PLAN FOR p LOCATION OF NEW EXTERIOR CL Z CEILING JOISTS WALL, SEE DETAIL 0:�Q oN ui J O OZ Z :�E 00 Lu � uQ 0u - w CL UJ o �z O a ujU M_ Lu (� m F— J 0= Z N J � Q0 1 SLOPE ROOF DETAIL MIN. :k" OSB/PLW. ROOF DECK. SEE / SHEATHING LEDGED FOR FASTENING SPECS. NU DECKS E TO BE IN ACCORDANCE C w/ ANSI/ASME B18.6.1 w Z UO ZU OLij LD� w X 100 nw Qa J 0 Q w Ww Lu F— — (1) SIMPSON A35 ANGLE CLIP AT EACH RAFTER LOCATION. 2x No. 2 SYP. SLEEPER, FASTEN TO EXISTING ROOF DECK W/ (2) #10 X 3.5" DECK SCREWS W/ 1" DIA. WASHER, ATTACH TO EACH EXISTING RAFTER/TRUSS. USE (4) DECK SCREWS FOR 2x10 SLEEPERS OR LARGER. EXISTING ROOF RAFTERS, VERIFY MIN. 2X6 RAFTERS OR TRUSSES AT 24" O.C. CONTACT ENGINEER IF EXISTING IS NOT MINIMUM SIZES/SPACING. ROOF OVERFRAMING DETAIL Z RIDGE BEAM/BOARD, No.2 SYP., SEE Z O PLANS FOR SIZES AND LOCATIONS w �w Q Z MIN. 21g" OSB/PLYW. ROOFBECK ZO w < ::E C) Lu J w J w Z ZZ �w ww w = Z F— (D = w� Z vi p -_Z cy--0 QN �z �w 0 SCALE: 1/2" = 1'-0' FASTEN SIMPSON A35 CLIPS FROM RAFTERS TO HIPS/RIDGES �— COLLAR TIES AT 16" O.C. W/ (8) 16d NAILS EACH END. SEE PLANS FOR SIZES AND LOCATIONS I NOTE: COLLAR TIE TO BE NO HIGHER NIM THAN 3 THE TOTAL HT. OF RAFTER COLLAR TIE/RIDGE DETAIL SCALE: 1/2" = 1'-0' I I U O N F- 4 a S -3a. NEW ROOF AR S TO MATCH N EXIST. ITCH 2x8 No. 2 SYP d 12x6 No. 2 SYP AT 24" O.C'l-j p 2gll 1.�� 01 04 11F un EiL _ 1424xl rv� D 2x6 No. 2 SYP AT 24" O.C. 1 S-3 VALLEY I z N x8 No. 2 SYP AT 24" O.C. I F I _I I� �2xB` �I I 3 11CID �, NII S-3 2x8 No. 2 SYP cD �IICEILING JOISTS AT (2) 2x8 I 24" O.C. 6 2 291IXO I 1 I i (i I 1 i i f III I I i i 2x6 No. 2 SYP I COLLAR TIES AT 24" X I I III I i a. I 1 I o O.C. V vII II04 A N IF r i i i i I 1 I I I I 2X10 NO. 2 SYP 2 I I 1 I O RIDGE BOARD. - I I I- 1 I I I I 1 1 N Lu V 2x6 No. 2 SYP AT 24" O.C. ^ " I UJ �3 I USE DETAIL 1 ON S-3 FOR I LEDGER/RAFTER FASTENING TO I I I WALL 2x8 No. 2 SYP SLEEPER4 2 I I I S-3 I i (2 2X8 No. 2 SYP RIDGE BEAM — GARAGE ROOF -FRAMING PLAN scnLe. 1/4" = l' -O" ROOF RAFTERS, SEE PLAN PLAN FOR SIZE AND SPACING Ca LLAR TIES, SEE PLAN & DETA LS FOR SIZE, SPACING, AND FASTENING SEE PLANS AN FRAMING NOTES FOR FRAMIN AROUND KYLIGHTS CEILING JOIST, SEE LAN FOR SIZE AND SPA ING 10' PLT. ROOF FRAMING PLAN_ RIDGE BOARD, SEE PLAN FOR SIZE & LOCATION ROO7---1 E PLAN FOR ON SLEEPER FASTENED TO EXIST. ROOF, SEE PLAN �--- EXISTING TRUSS 2x No. 2 SPF PONY WALL —� --- INSTALL 2x12 No. 2 SLEEPER FOR NEW CEILING PER DETAIL 2 ON THIS SUPPORT, FASTEN TO SHEET. FASTEN CEILING EXIST. TOP PLATE w/ 10d JOIST TO SLEEPER w/ (8) 16d NAILS AT 6" O.C. TOE -NAILS KITCHEN I I EXIST. LIVING ROOM SECTION AT KITCHEN/LIVING ROOM SCALE: 1/4" = 1'-0' 8' PLT. HT. OUTDOOR KITCHEN SEE PLAN FOR LO, 1 S-3 I I I 1 I I I I I Lu F - Q D v) (2) 2x6 No. 2 SYP HIP O z BEAM O a. R to o 4C 2x6 No. 2 SYP ROOF RAFTERS AT 24" O.C. 0 z 2x6 No. 2 SYP CEILING JOISTS AT 24" O.C. Z 2z8 No. 2 SYP :i� J SLEEPER W ULU LL �- Z > _ ZC)Q Q W �m H 0WW. � O��U.Q Opo 00 SECTION AT OUTDOOR KITCHEN ;S, SEE PLAN (CATION T. HT. SCALE: 1/4" = 1'-0' • V ,^, N to N cq Z > M O L m N Lu V ti' ^ " N UJ �3 M L Q o �. ;z V..... F- �- Q oG N ^.. INV ■ ■ ■ ■ PROJECT #: 18-305 DESIGNED: KCM DRAWN: KCM SCALE: AS NOTED ISSUED: 8/16/18 REVISION -1: REVISION -2: ovo`�®®ro�a►raie®,® e®000 J`N C M e 03 13 STA OF a ,,,®�% KEVIN C. MARTIN, PE #80359 SHEET S-3 U w w oe `0 U r U- _cy- w > Z 0 _ V) 0 Z w J z 0 V) z 0 z U-1 Z w > (D Lu V) V) z Q LU Q N 0 Z r) J J z Lu w Z z 1w z Q w L z U.1 V) z 0 U z w 0 w CL 0 3- a Q�w �- co 00 �Q OZ r0 Z Qp z O <0 0 Q ON Lu Z O 0 = z Z�,> _ Q U �Q )LL- �w Lu > 0! p OQ Ne LuU vi w D_ wU m J F— J OQ Z= J N J ry ¢0 NU V, -)a CL W Lu '_ Uz z0 OU U u.i Z Q Q:�i N X � � oq- QCL Q _10 gw FT, Lu Q Z0 Lu Lu 1Z NO w Q::E r) Lu ULu J w J w Z z clew ww w= ZF- uj3 z� 1= z �•o QN �z �w 00 MIN. -s" APA RATED OSB ROOF DECK. SEE FRAMING PLAN FOR DETAILS 2x FASCIA FASTEN TO TRUSS/RAFTER TAILS w/ 11000 (2) 16d NAILS, TYP. SEE TRUSS PLAN OR ROOF FRAMING PLAN FOR ROOF TO TOP PLATE CONNECTIONS. APA RATED OSB/PLYWOOD SHEATHING. SEE FRAMING PLAN FOR FASTENEING AND OTHER SHEATHING SPECS. ALL WALL SHEATHING TO EXTEND TO BOTTOM PLATE & BE NAILED AT 3" O.C. U.N.O. PRE-ENGINEERED TRUSSES OR CONVENTIONAL ROOF FRAMING. SEE TRUSS PLAN OR ROOF FRAMING PLAN. �-- GYPSUM WALL BOARD, FASTEN PER FBC TABLE R702.3.5 (2) 2x No. 2 SYP TOP PLATE FASTENED w/ 2 ROWS OF .131x3" NAILS AT 12" O.C. STAGGERED. MINIMUM 48" LAP WITH (24) .131x3" NAILS IN LAP. WALL SHEATHING SHALL EXTEND TO TOP STUD OF DBL. TOP PLATE IN ALL LOCATIONS. FASTEN SHEATHING PER FRAMING PLAN & SHEATHING FASTENING DETAILS GYPSUM WALL BOARD, FASTEN PER FBC TABLE R702.3.5 2x SPF No. 2 STUDS. SEE FRAMING PLAN FOR SIZE, SPACING, AND LOCATIONS 2x No. 2 SYP PT BOTTOM PLATE. FASTEN TO FOUNDATION w/ MIN. �' ANCHOR BOLTS PER FRAMING PLAN SEE FOUNDATION PLAN FOR FOOTING DETAILS. TYPICAL WALL SECTION DBL. TOP PLATE. FASTEN T/G PER DETAILS, TYP. CORNER STUD GROUP SILL PLATE CORNER 2x FRAMING (2) ROWS OF 10d NAILS AT 8" O.C. INTO TRIPLE GROUP USE 10d NAILS 8" O.C. FOR S7 GRC_. �— SILL PLATE PLAN NOTE: ADD (1) ADDITIONAL ROW OF NAILS AT EACH STUD FACE FOR 2X6 &2X8 FRAMING LAP TOP & BTM. STUDS IN TOP PLATES AT ALL CORNERS. FASTEN STUDS TOGETHER w/ (5) 16d NAILS 4 CORNER FRAMING DETAIL FLOOR SYSTEM: FASTEN I! FLOOR TRUSS/JOISTS/RIM � BOARD TO TOP PLATE PER ^, 0 FASTEN SHEATHING TO HEADER W/ (2) ROWS MIN. J" THREADED TYPICAL WALL SECTIONS 0 2x SPF BLOCKING/NAILERS B.T OF 8d NAILS @ 6" O.C. FOR 2X10 HEADERS OR EACH TRUSS OR ALONG TOP U. " FLOOR OR ROOF SYSTEM GREATER FASTEN w/ 3 ROWS ROOF SYSTEM: FASTEN FASTEN TO BEAM w/ 10d NAILS LL HEADER BEAM PER FRAMING PLAN. FASTEN AT 3" O.C. TRUSSES/RAFTERS TO TOP UJI p 0 • ° ° ° ° ° TOGETHER W/ (2) ROWS OF 10d NAILS @ 8" 2x SPF BLOCKING/NAILERS PLATE PER TRUSS PLAN OR ROOF FRAMING PLAN V_ • °° ° ° ° ° °TOP O.C. SEE FRAMING PLAN FOR SIZES. B.T EACH TRUSS OR ALONG PLATE(PARALLEL FASTEN SHEATHING TO DBL. ° ° ° ° ° ° • AT EACH HEADER END, NAIL SHEATHING TO 8d NAILS, TYP. TRUSSES). FASTEN TO DBL. TOP PLATE PER SHEARWALL 1 PER TYP. ANCHOR HEADER W/ (6) TOP PLATE w/ 10d NAILS AT LEDGED ON FRAMING PLAN ° ° • • FASTEN KING STUD TO HEADER BEAM PER 3" O.C. V ° ° ° ° ° TABLE SHOWN ON THIS DETAIL F_ z FASTEN SHEATHING AT CRIPPLES W/ 8d NAILS MIN. S" PLYWOOD OR OSB LAj o @ 3'0.C. STAGGERED FROM HEADER FASTENED TO PORCH CEILING ROOF FRAMING w/ TYPICAL WALL SHEATHING -, .° BEARING TO SILL PLATE. 8d NAILS AT 3" O.C. ALONG PER SHEAR WALL LEGEND OPENING VARIES ° FASTEN SHEATHING AT KING STUDS PER EDGES & 12" O.C. IN FIELD, NP' ON FRAMING PLAN qr a TYPICAL VERTICAL SPACING ON SHEARWALL ^ LEGEND IN ° KING & JACK STUDS PER FRAMING PLAN, TYP. Ai FOUNDATION: ANCHORS REQ. T ° ° • ° ° ° ° ° ° ° FASTEN KING & JACK STUDS TOGETHER w/ (2) TYPICAL EXTERIOR BEARING WALL. SEE FOUNDATION & WITHIN 6" MAX F ° ROWS OF 10d AT 8" STAGGERED, TYP. FRAMING PLAN & KING/CRIPPLE UNIT, U.N.O. S E • SHEARWALL LEGEND FOR REQ. • NAIL SILLS & PLATES TO JACKS W/ (3) 8d TYPICAL WALL SECTIONS 16" O.C. • . 6"TOENAILS OR ENDNAIL, TYP. FLOOR SYSTEM: FASTEN SILL �O ° TYP. WALL FRAMING PER FRAMING PLAN. BAND/RIM BOARD PER TYPIC L ° ° FASTEN TO PLATES w/ (2) .131 x 3" END NAILS WALL SECTIO S Alf • ° ° ° • ° • ° ° ° ° OR (3) .131 x 3 TOENAILS, TYP. TYPICAL WALL FASTEN SHEATHING TO BOT. PLATE PER FOUNDATIONS. SEE KING STUDS TO HEADER NAILING LY FOUNDATION OR FLOOR SYSTEM SHEARWALL LEGEND ON FRAMING PLAN FOUNDATION PLAN & DETAILS 2X6 (3) NAILS PER 2X8 (4) NAILS PER LY 2X10 (5) NAILS PER LY 2X12 (6) NAILS PER LY 9.5" LVL (5) NAILS PER LY 11 j"LVL (6) NAILS PER LY 14" LVL (7) NAILS PER 16" LVL (8) NAILS PER LY PLY �,�� TYPICAL HEADER DETAIL SEE SHEAR WALL LEGEND SEE SHEAR WALL LEGEND ONE STORY SHEATHING FASTENING FASTEN A MIN. OF (4) 8d NAILS AT 3 O.C. ON EACH SIDE OF HORIZ. PANEL SPLICE. RETURN TO "-- --�-, FIELD/EDGE SPACING THEREAFTER NAIL SPACING TO BE 6" O.C. AT HORIZONTAL SPICE EDGES B/T STUDS ONLY. SEE SHEAR WALL LEGEND FOR ALL OTHER FASTENING SPECS. INSTALL BLOCKING 2x FLATWISE BLOCKING (IF APPLICABLE) PER THE SHR WALL LEGE D ON FRAMING PLAN FIELU SrAUr4k SHEARWALL L NAIL SPACINP AT 12" O.C. MFOR INTERMEDIATE SUPPORTS, N.O. VERTICAL EDGE SPACING PER SHEARWALL LEGEND 2x FLATWISE BLOCKING w/ SHEATHING SPLICE PLATE NAIL SPACING AT EACH SIDE OF SPLICE PER SHEARWALL LEGENED M 6r o.c. "— 'AANUF. TRUSSES OR (ENTIONALLY FRAMED PER SHOP DRAWINGS 3R TRUSS PLAN PORCH BEAMS. SEE FRAMING PLAN FOR SIZES. FASTEN EACH PORCH BEAM TO POST (3) 16d TOE -NAILS & z (1) MSTA24 STRAP SIMPSON STRAP. No. 2 SYP PT. PORCH POST. SEE PLAN FOR SIZE & LOCATION • z SIMPSON ABU HOLDOWN. SEE W DETAIL FOR SPEC. /1 w > .. PORCH POST FTG. SEE FOUNDATION PLAN &DETAILS W /T W L in 0 ry U — PORCH FRAMING DETAIL _ W �-- 3 5 z=z U) Q Q O0 j U. 00 Q � ^, 0 z MIN. J" THREADED 0 2x SPF BLOCKING/NAILERS B.T U;P EACH TRUSS OR ALONG TOP U. " in. BEAM(PARALLEL TRUSSES). ad u FASTEN TO BEAM w/ 10d NAILS LL MIN. 3"x3"X 1/4" SQUARE AT 3" O.C. QG UJI p PORCH BEAMS. SEE FRAMING PLAN FOR SIZES. FASTEN EACH PORCH BEAM TO POST (3) 16d TOE -NAILS & z (1) MSTA24 STRAP SIMPSON STRAP. No. 2 SYP PT. PORCH POST. SEE PLAN FOR SIZE & LOCATION • z SIMPSON ABU HOLDOWN. SEE W DETAIL FOR SPEC. /1 w > .. PORCH POST FTG. SEE FOUNDATION PLAN &DETAILS W /T W L in 0 ry U — PORCH FRAMING DETAIL _ W �-- 3 5 z=z U) Q Q O0 j U. 00 Q 31 DRILL &EPDXY INTO FTG. a i 1 a W PER TYPICAL ANCHOR I 1 oN DETAIL BELOW a °0 1 0 1�Oo. P Zw. • . 0 •°O1• =—°--1 N THREADED ROD HOLD DOWN ' I54,51DTT2Z HOLDOWN MIN. 3"x3"X 1/4" SQUARE Z WASHER & NUT EDGE OF WASHER TO BE WITHIN �' OF SHEATHED SIDE OF WALL SPLICE BETWEEN STUDS SPLICE BETWEEN STUDS (ALTERNATE) 5 �T1(PICAL SHEATHING FASTENING A -A 2x FLATWISE BLOCKING SHEATHING SPLICE PLATE. SAME SIZE, TYPE, & ORIENTATION AS SHEATHING. TYPICAL ANCHOR PRESSURE TREATED POI POST. SEE PLAN FOR SIZ LOCATION ABU66Z POST BASE. FILL ALL HOLES w/ 16d NAILS. ABU44% J" ANCHOR BOLT OR THREADED ROD. ABU66: J" ANCHOR BOLT OR THREADED ROD. ABU88: (2) J" ANCHOR BOLTS OR THREADED ROD. �— TYP 2x P.T. SOLE PLATE THREADED ROD:DRILL & EPDXY 1/2" THREADED ROD w/ MIN. 7" EMBEDMENT INTO FOUNDATION. OR TITEN HD: �' TITEN HD ANCHOR 12"LG. 2x PT SOLE PLATE,TYP 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 O O MIN. 2 -PLY STUD GROUP OR 3"x3.5" MEMBER SIZE FILL ALL HOLES w/ 16d x 2" NAILS OR #10x1 J" SD FASTERS, PER SIMPSON SPECS. MINIMUM 5/8" THREADED ROD HTT5 HOLDOWN ABU44Z (ABU66, ABU88 similar) 6 TYPICAL ANCHOR DETAILS 2x PT SOLE PLATE,TYP DRILL & EPDXY 5/8" THREADED ROD w/ MIN. 7" EMBEDMENT INTO FOUNDATION. V MIN. 2 -PLY STUD GROUP OR ^, 3"x3.5" MEMBER SIZE MIN. J" THREADED N FILL ALL HOLES w/ T" x 2.25" ROD ANCHOR V ^N SIMSPON SDS SCREWS, Z � TYP. MIN. 3"x3"X 1/4" SQUARE --j mu" MINIMUM 1/2" WASHER & NUT N N.� V_ THREADED ROD w/ NUT OR HD TITEN ANCHOR TYP. DBL. 2x FASTEN ANCHOR TO FTG. TOP PLATE 1 PER TYP. ANCHOR • 1 DETAIL BELOW 31 DRILL &EPDXY INTO FTG. a i 1 a W PER TYPICAL ANCHOR I 1 oN DETAIL BELOW a °0 1 0 1�Oo. P Zw. • . 0 •°O1• =—°--1 N THREADED ROD HOLD DOWN ' I54,51DTT2Z HOLDOWN MIN. 3"x3"X 1/4" SQUARE Z WASHER & NUT EDGE OF WASHER TO BE WITHIN �' OF SHEATHED SIDE OF WALL SPLICE BETWEEN STUDS SPLICE BETWEEN STUDS (ALTERNATE) 5 �T1(PICAL SHEATHING FASTENING A -A 2x FLATWISE BLOCKING SHEATHING SPLICE PLATE. SAME SIZE, TYPE, & ORIENTATION AS SHEATHING. TYPICAL ANCHOR PRESSURE TREATED POI POST. SEE PLAN FOR SIZ LOCATION ABU66Z POST BASE. FILL ALL HOLES w/ 16d NAILS. ABU44% J" ANCHOR BOLT OR THREADED ROD. ABU66: J" ANCHOR BOLT OR THREADED ROD. ABU88: (2) J" ANCHOR BOLTS OR THREADED ROD. �— TYP 2x P.T. SOLE PLATE THREADED ROD:DRILL & EPDXY 1/2" THREADED ROD w/ MIN. 7" EMBEDMENT INTO FOUNDATION. OR TITEN HD: �' TITEN HD ANCHOR 12"LG. 2x PT SOLE PLATE,TYP 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 O O MIN. 2 -PLY STUD GROUP OR 3"x3.5" MEMBER SIZE FILL ALL HOLES w/ 16d x 2" NAILS OR #10x1 J" SD FASTERS, PER SIMPSON SPECS. MINIMUM 5/8" THREADED ROD HTT5 HOLDOWN ABU44Z (ABU66, ABU88 similar) 6 TYPICAL ANCHOR DETAILS 2x PT SOLE PLATE,TYP DRILL & EPDXY 5/8" THREADED ROD w/ MIN. 7" EMBEDMENT INTO FOUNDATION. V ^, N Ln V ^N Z � M O� --j mu" to �N N N.� V_ °► Lu V F_ z o ON LAj 0 L.t.. v) MANNMANN �- qr a ^ IN Ai s s mass ■ ■ ■ ■ PROJECT #: 18-305 DESIGNED: KCM DRAWN: KCM SCALE: AS NOTED ISSUED: 8/16/18 REVISION -1: REVISION -2: 8 _10 STAT OF ° ®O N A�,�®®� KEVIN C. MARTIN, PE #80359 SHEET S-4 GENERAL DEMOLITION NOTES: 1. ALL DEMOLITION WORK TO BE PERFORMED UNDER G.C. CONTRACT. G.C. TO FIELD VERIFY ALL EXISTING CONDITIONS. 2. SURVEY EXISTING CONDITIONS OF THE BUILDING TO DETERMINE IF REMOVING ANY ELEMENT MIGHT RESULT IN STRUCTURAL DEFICIENCY TO ANY PORTION OF THE STRUCTURE OR ADJACENT STRUCTURES. NOTIFY THE ARCHITECT AND STRUCTURAL ENGINEER IN WRITING PRIOR TO COMMENCING ANY ADDITIONAL WORK FOR DIRECTION IF DEFICIENCIES ARE NOTED. 3. TURN OFF NECESSARY POWER AND UTILITIES PRIOR TO COMMENCING ANY DEMOLITION WORK. 4. ITEMS INDICATED TO BE REMOVED SHALL BE REMOVED AND LEGALLY DISPOSED OF IN ACCORDANCE WITH APPLICABLE CODES. 5. PROTECT EXISTING ITEMS TO REMAIN. THESE ITEMS TO BE COORDINATED WITH THE OWNER PRIOR TO ANY DEMO WORK. 6. DEMO AND REMOVE EXISTING INTERIOR DOOR / DOOR FRAME / DOORSILL /CASING UNLESS OTHERWISE NOTED (U.O.N) ON PLAN. 7. CUT OPENINGS NEATLY AND HOLES PLUMB, SQUARE AND TRUE TO DIMENSIONS REQUIRED. USE CUTTING METHODS LEAST LIKELY TO DAMAGE CONSTRUCTION TO REMAINING OR ADJOINING CONSTRUCTION. 8. ANY FIRE EXTINGUISHERS TO BE REMOVED AND STORED FOR FUTURE USE. 9. AUTHORIZED CONSTRUCTION PERSONNEL ONLY WITHIN THE CONSTRUCTION AREA. 10. WORK TO BE DONE IN SUCH A MANNER AS TO HAVE MINIMUM DISRUPTION TO ONGOING CITY BUSINESS AND PARKING LOT. 11. CODES AND REGULATIONS: COMPLY WITH GOVERNING CODES AND REGULATIONS. 12, USE EXPERIENCED WORKERS. 13. OCCUPANCY: IMMEDIATE AREAS OF WORK MAY BE OCCUPIED DURING DEMOLITION BY THE HOME OWNERS. 14. DEMOLISH DESIGNATED IMPROVEMENTS AS NECESSARY TO IMPLEMENT RENOVATION PLAN. 15. IMPLEMENT POLLUTION CONTROL DURING BUILDING DEMOLITION. 16. HAZARDOUS MATERIALS: IF HAZARDOUS MATERIALS ARE NOTED THEY WILL BE REMOVED UNDER SEPARATE CONTRACT. NOTIFY OWNER IF HAZARDOUS MATERIAL IS DISCOVERED TO BE PRESENT. 17. DO NOT DAMAGE BUILDING ELEMENTS AND IMPROVEMENTS INDICATED TO REMAIN. ITEMS OF SALVAGE VALUE, NOT h SPECIFIED ITEMS TO BE RETURNED TO OWNER, SHALL BE REMOVED FROM STRUCTURE. STORAGE OR SALE OF ITEMS IS PROHIBITED. 18. UTILITIES: LOCATE, IDENTIFY, DISCONNECT, AND SEAL OR CAP OFF UTILITIES IN AREAS TO BE DEMOLISHED. 19. SHORING AND BRACING: PROVIDE AND MAINTAIN INTERIOR AND EXTERIOR SHORING AND BRACING AS REQUIRED. 20. OCCUPIED SPACES: DO NOT CLOSE OR OBSTRUCT STREETS, WALKS, DRIVES, PARKING SPACES OR OTHER OCCUPIED OR USED SPACES OR FACILITIES WITHOUT THE WRITTEN PERMISSION OF THE OWNER AND THE AUTHORITIES HAVING JURISDICTION. DO NOT INTERRUPT UTILITIES SERVING OCCUPIED OR USED FACILITIES WITHOUT THE WRITTEN PERMISSION OF THE OWNER AND AUTHORITIES HAVING JURISDICTION. IF NECESSARY, PROVIDE TEMPORARY UTILITIES. 21. RESTORATION. RESTORE FINISHES OF PATCHED AREAS. DEMOLITION KEY NOTES 1. REMOVE ALL WALL PARTITIONS INDICATED BY DASHED LINES, INCLUDING ALL GLAZING AND TRIM. 2. REMOVE ALL MILLWORK, INCLUDING ALL PLUMBING FIXTURES & APPLIANCES INDICATED BY DASHED LINES. 3. REMOVE ALL EXISTING FLOORING AND WALL FINISHES SHOWN FOR DEMOLITION ON THESE DRAWINGS. PATCH UNEVEN SURFACES AND PREPARE FOR NEW FINISHES. 4. REMOVE EXISTING DOOR/WINDOW AND FRAME. PREPARE FOR NEW WALL AND/OR OPENING AS SHOWN IN NEW PLAN. N H co I1 � I I N N BEDROOM H CLOSET EDROOM EXISTING u EXISTING EXISTING REMOVE & INFILL EXISTING DOOR OFFICE \\ ^ I \\ EXISTING 03: — __ \ —I[ I �I� loo \— — — — — — — 0 1 Z coQ Wo �z II � II PLAYROOM ® EXISTING 0 O O II II 'i BEDROOM STORAGE EXISTING EXISTING -� SECOND FLOOR DEMOLITION PLAN SCALE: 114" = T-0" LIVING ROOM EXISTING 8' CLG ------------------ MASTER BATH EXISTING I EXISTING4" STEP KITCHEN60 i� EXISTING PREVIOUS EXTERIOR 4� i WALLS TO BE REM VED REMOVE - STRUCTURAL EWq]NEER TO & INFILL rA \ REDESIGN W/ BEf/ !SATO ALLOW FOR EXISTING DOO 8' CEILING HEI rT TO CONTINUE ADDITION 4" SLAB TO BE REMOVED w z 2� REMOVE " 73 FINISHED FLOOR TO ALIGN WITH �XITIAIG� EXISTING LIVING ROOM FINISHED SIU SHOWER FLOOR w p PREPARE LIMIT OF SLAB DEMO z = FOR NEW EXISTINGTOILETEW 4" STEP LOCATION TO REMAIN MASTER BATH 2� 2� EXISTING o _ MASTER I — o / CLOSET 4EMovE DINING KITCHEN EXISTING EXISTING VANITY REMOVE ROOM REMOVE ALL 1 3 PREPARE FOR NEW EXISTING TRAY CLG TO BE CABINETRY, / TUB REMOVED AND 2� APPLIANCES & 2� (( PREPARE CEILING HEIGHT I' PLUMBING FOR NEW TO BE INCREASE FIXTURES TO BE J MAX POSSIBLE RELOCATED IN NEW KITCHEN LOCATION / ------ IT -----0 FAMILY ROOM EXISTING FIRST FLOOR DEMOLITION SCALE: 1/4" = 1'1-0" �/// - - - _j PLAN i EXISTI i Julianne N. Over,by, RA Architectural and Interior Design Julianne N. Overby, R.A. 2452 Pulban Street Jacksonville Beach, Florida 32250 904-704-8628 Email: jnoverby@att.net FL. AR -0017060 • FI-,. ID -4621 W U M M zzN N W w cY) J Q � U_ U) T_ � W W m Ur 2U z u) o - z :D00J (N O � Q DATE ISSUED: JULY 30, 2018 NOTE: DO NOT SCALE DRAWINGS. IF PRINTED ON 11 "X17" MEDIA, DRAWING SCALE IS HALF -SIZED. DEMOLITION PLANS PERMIT SET wN X zch: w mo O J ~ J �LL Oz o06 z �w w z� U)W X LL] R-0" EXISTING "OTES -,ALE DRAWINGS.US ONLY DIMENSIONS SHOWN ON �. IF DIMENSIONS AR : IN QUESTION, THE BUILDER RESPONSIBLE FOR O TAINING CLARIFICATION ;ONTINUING WITH CO STRUCTION. BUILDER SHALL L DIMENSIONS & CO DITIONS AT JOBSITE. NS SHOWN ARE TO F CE OF FRAMING OR NE OF STRUCURE UNLESS OTHERWISE NOTED. 1OORS SO THAT DOO CASING ABUTS WALL FINISH OF T WALL UNLESS OTHERWISE NOTED. SHALL COORDINATE LL SHELVING & STORAGE GENTS WITH DESIGNER OR OWNER. 'ENT OF ANY DISCREP NCIES, IMMEDIATELY NOTIFY ER. DO NOT PROCEE WITH AFFECTED WORK UNTIL I ISSUES HAVE BEEN 'ULLY RESOLVED. ;TRUCTION SHALL BE ERFORMED IN ACCORDANCE CODES, REGULATION AND RESTRICTIONS HAVING TION. 34'4%2' EXISTING 27'-5" 18'-8%2' W EXISTING > DRIVE I o SIDE PROPERTY LINE T ARCHITECTURAL SITE PLAN SCALE: 1/16" ELECTRICAL LEGEND TV CABLE 1820 SHERRY DRIVE N. DUPLEX OUTLET ATLANTIC BEACH, FL 32233 220 OUTLET Ail NfT QUADRAPLEX OUTLET @ GFI GFI RECEPTACLE @ wP EXTERIOR/GFI RECEPTACLE NEW A/C: 322 SQ. FT. SWITCH 3 3 -WAY SWITCH SD SMOKE DETECTOR CM CARBON MONOXIDE DETECTOR CH COUNTERTOP HEIGHT NOTES: 1. TELEPHONE OUTLETS TO BE 'CAT 5E' WIRE. 2. SMOKE DETECTION PER FIRE CODE. 3. SERVICE PANEL AND ELECTRIC METER LOCATION TO BE DETERMINED W/ INPUT FROM THE OWNER AND LOCAL UTILITY COMPANY. 4. ALL RECEPTACLE TO HAVE ARC -FAULT CIRCUIT INTERRUPTERS PER ARTICLE 210-12. 5. HVAC DISCONNECT TO BE PROVIDED BY MECHANICAL SUBCONTRACTOR. 6. ALL ELECTRICAL WIRING TO BE IN ACCORDANCE WITH LATEST EDITION OF NEC AND FBC. 7. 100% OF ALL INTERIOR AND EXTERIOR PERMANENT LIGHT FIXTURES TO USE CFL/LED LAMPS. 5'-0" OVERHANG o T- JII I I N I (Dout)000 I U)oao0� 0 1 ��=w U o Ow��� I I w� ;ow a- a Z 13'-10" I 4'-0" - — — — — — — — — — — — — — ►• . LO I OUTDOOR 17'J" ALIGN W/ EXISTING IN •• X11 �'�11111 LIVING AREA CH VAULTED T&G CEILING PROVIDE SKYLIGHTS PER OW R I \ 11'-6" SELECTIONS & LOCATIO Z Cii 3' 6" 7'-0" LU � _ M�IRdIXE I S I I w I Y o ' ---�� - 1 11 11 11 =1 "4'� o _ z Offi-----�-- -1 M I L LULOO A2 I I 1 141.5"x4. I o O (3 r— - i 1 ' II I l I I ctcTwtS+Fy-Ef T�� LO O I I I I I CH 130"X45.75" 1 130"X45.75" I �p _ _ KITCHEN _ I 3:I SKYLIGHT — — — — 10' CEILING LSKYLIGH J L — _ J 1OVEN NEW DESIGN 1 2'-8"x5' DH 2'-8"x5' H BY OTHERS WINDOW[REPLACE WINDOW 3 1 o REMOVE EXISTING WINC - NEW CASED OPENINC 4'-1" 12'-4" 7'-3" 6_0" 7,- L FIRST FLOOR PLAN SCALE: 1/4" = V -D" FAMILY ROOM EXISTING YOUNG RESIDENCE RENOVATION PROJECT ADDRESS DRAWING INDEX 1820 SHERRY DRIVE N. Al RENOVATION PLANS ATLANTIC BEACH, FL 32233 A2 EXTERIOR ELEVATIONS AND DETAILS WORK AREA - w EXISTING FIRST FLOOR A/C: 1,480 SQ. FT. LLJ EXISTING SECOND FLOOR A/C: 1,315 SQ. FT. z o NEW A/C: 322 SQ. FT. NEW TOTAL A/C: 3,117 SQ. FT. NEW A/C VOLUME: 3,222 CU. FT. TO BE INCREASE BUILDING CODE SUMMARY CODE ENFORCEMENT JURISDICTION: CITY OF ATLANTIC BEACH WIND ZONE: 130 MPH (WIND-BORNE DEBRIS) FLORIDA BUILDING CODE 2017 - 6TH EDITION OCCUPANCY CLASSIFICATION: RESIDENTIAL (R-3) CONSTRUCTION TYPE: TYPE V -B (WOOD FRAME ADDITION) SPRINKLED!: NO FIRE DISTRICT: NO rA A2 LIVING ROOM EXISTING 8' CLG 10'-0" EXISTING to0 o ROOM UM z TRAY CLG TO BE zz" w REMOVED AND LLJ COJ z o CEILING HEIGHT C) F- o TO BE INCREASE U) o X cwn TO MAX POSSIBLE w w 0 �m ow Ur 2U) U Z w w z C� Q 2/6 00 J O � Q z i 4" STE 0 LAUNDRY REMOVE EXISTING KITCHEN CABINETRY, FIXTURES, APPLIANCES 9-------- D MUD ROOM DVIL I-IIVJ .XISTING ELECTRICAL TO REMAIN / \ \ ALIGN W/ EXISTING / i / I � I / I 1 -5 I I ---- — — — — — — — — — -- — — I I X CLOSET I I w z 8' CLG O X MASTER o z z I I w 8'CLG OF - a \ �wo � 28 \ �\ zzo 1 3-0" 5'-6" EXI TIN 2/6 2/4 \ WALK-IN z 1 w � w = QU) UNPIN /0 , w C CLO ET o NA2 w + I MASTER/0 \� z I BATH 1 4/0 8' CLG l NEW x34" 1 6' 10" NEW VANITY FRE TANDIN z I CLOSET ATHUB O 1 610" CLG —I------- H v EX / RELOCATE HVAC UNIT �? E G I- - Julianne N. Overby,RA Architectural and Interior Design Julianne N. Overby, R.A. 2452 Pullian Street Jacksonville Beach, Florida 32250 904-704-8628 Email: jnoverby@att.net FL. AR -0017060 • FL,. ID -4621 W UM M zz" N W LLJ COJ � C) U) o z Ww w � �m w Ur 2U) U Z o Z 00 J O � Q DATE ISSUED: JULY 30, 2018 NOTE - DO NOT SCALE DRAWINGS. IF PRINTED ON 11 "X17" MEDIA, DRAWING SCALE IS HALF -SIZED. RENOVATION PLANS GARAGE EXISTING PERMIT SET _ ---- -- --- ---- } c II^ N4 - IUUDq F RAi" E GON&T 2 '10, I SEE STRUCTURAL W;.)Otu INST.A:.LATION 1KTNOfJ !FSC.-<T✓3.8� 3 CODE GO i'L'�ANT � ) AFFliE:J FR!02 TO TOE WIhCO'k !`18TALl.4TIChi. - I 'A7FLR Rr91Tl� SARR:eR F-•Gc CF ;aE I"GUVTfr:� FL: �E. EG)V,KR RE53TA.' METAL HURRICANE CLIP AF�LI"G P_YEL+ 'HE { • '3YxE, Ca�R+--Y Q.T TLK- i-1EpA'�CR'sF BY CODE - /a 11A-. �Nr-T PP 2F W:J Af-E TA[G NdriR mom SEE STRUCTURAL wNJane 1 W u':wreRs�sccMa P.cs-Fcv:. ____'L+Lso%.N _�a:.' _____________..___.. _.. NOTES: =U T.:E sACE OF TYZ ,'r eEµLN- 3Ap '•.� \\ `l4 t m ---sill pan p 2. cover sill to at least depth of windOW, plus 2" onto face of wrt SNEAIIilri n, nCtTliTl-+ i i O i (y LoFLY EILI. FiASHI[Y :4or6"J NJGE1 \ ), �� 1 - % slit plate _) Aa+pLY EEnJ W EEALANi %\ — barrier to form water shedding laps _— G,%IJNPNUCnNp� 30TTU' FL.Y1+< �EA�R-!a ." rkfrt :: A 1 r WTE .IOR pF T1C W4=PLA`�E R Lv.E V=1- see n ote#2 ----.: - } rv: ga=s 1 ua �, ANT-. �-ti*_L+Ec �OLEs o aLo-a weather resistive — / barrler wall sheathing Prepareo by 604F Ftrat Goaet Ghaptsr 9-l1 iG l3 oCI)EYu TO FACI!'TAiE I•�pEca1 1 L?�LLANT nE/.p c:itiE�N 1 �'7<: YY IaY�E LI.LSNIR. 1 aa%.- :;ONT. r£.11, rV THE Y.dJN'f:tY F_MYsES Ai' - - tIJZ SOI° li;Ei?) aND 91DE5 tJa:^B=J L: y7fipC'il . �' A°ppl-Y ECAO cr sEA:.a t 1 '•� prwec .iA*IE rLasl+r.0 vTo 9Ea.L�Yfi An RASTEN O R 5 .. A' N:.AC M F: l.LF. i£. adilN, aCF6 lS x /. f a^PLY H'caG RLA9-1!JG ` t1 l RE`1G'✓E FF4iG'Y-Y :FF -IE: t0 LaY 11 �f /. LfE, LL QL1 L PLAT 6✓E. EL? PLL..M�N6. �� rt �W�IFAT�.NG TnPE ,, / �: � i SF. �fFI,F I s�w NOTE: THIS DETAIL USED FOR DOORS & WINDOW. ALL FLASHING TO MEET FBC R903.2.1, R905.2.8. & R703.8 AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. 12 ASPHALT SHINGLE SEE STRUCTURAL y 3 S.VYA C)ACT `OJ tO AJA — WkAGu.",A.F.FnL1URER E"EGfFI-ATIG�Iv.` STEMWALL EXT. SHEATHING EG)V,KR RE53TA.' METAL HURRICANE CLIP SEE STRUCTURAL { • '3YxE, Ca�R+--Y Q.T TLK- i-1EpA'�CR'sF BY CODE - /a 11A-. �Nr-T PP 2F W:J Af-E TA[G NdriR mom SEE STRUCTURAL GCeriER TO TLS LIRE Gf84GE AHOVE ' w-ERiOR VIEW W TO� L,.. _ W � wm NOTES: =U i. flashing to be Flexible self -adhesWe type (min. 4" vddeJ U) o `l4 t m ---sill pan p 2. cover sill to at least depth of windOW, plus 2" onto face of wrt C\1 00J . —sloped surhace O � �/.` (optional} 3, the pan shall direct water N the exterior oval stl flashing Q 1 % slit plate 4, Insall flashing around remaining window unit barrier to form water shedding laps 5. weaNer resistive see n ote#2 ----.: } ly,' `NF SILL PAN FLASHING weather resistive — / -- ::........... _,... _.--..—:........------ NTSticJnel) barrler wall sheathing Prepareo by 604F Ftrat Goaet Ghaptsr 9-l1 iG l3 NOTE: THIS DETAIL USED FOR DOORS & WINDOW. ALL FLASHING TO MEET FBC R903.2.1, R905.2.8. & R703.8 AND INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. METAL DRIP OVER g VINYL FASCIA OVER 2X6 SUB FASCIA TO MATCH EXISTING VARIES MATCH EXISTING OVERHANG 2X4 EXTERIOR WALLS W/ OSB SHEATHING WRAPPED IN WATERPROOFING MEMBRA.I\IE INSTALL HARDIPLANK LAP SIDING PER MANUFACTURER'S RECOMMEPv'JDATIONS R-38 INSULATION 1/2" GYP. BOARD NEW ROOF LINE TO MATCH EXISTING n -- m F L_EXTERIOR FINISH TO MATCH EXISTING Ilm CLG. = 8'-0" -- - -- - - STEM WALL PAINTED ___LF. F-. -13 INSULATION NEW CLOSET ADDITION'I TO ALIGN W/ EXISTING REAR ELEVATION A2 SCALE:1/4" = 1'-0" 0 I 0 r 2"x4" BOTTOM PLATE 4" CONCRETE SLAB OVER 12 ASPHALT SHINGLE SEE STRUCTURAL ROOF ON 15# ROOFING 6 F MATCH TO MATCH EXISTING EXISTING FELT OVER 7/16" STEMWALL EXT. SHEATHING CONT. CONCRETE METAL HURRICANE CLIP SEE STRUCTURAL AS REQUIRED BY CODE - SEE STRUCTURAL METAL DRIP OVER g VINYL FASCIA OVER 2X6 SUB FASCIA TO MATCH EXISTING VARIES MATCH EXISTING OVERHANG 2X4 EXTERIOR WALLS W/ OSB SHEATHING WRAPPED IN WATERPROOFING MEMBRA.I\IE INSTALL HARDIPLANK LAP SIDING PER MANUFACTURER'S RECOMMEPv'JDATIONS R-38 INSULATION 1/2" GYP. BOARD NEW ROOF LINE TO MATCH EXISTING n -- m F L_EXTERIOR FINISH TO MATCH EXISTING Ilm CLG. = 8'-0" -- - -- - - STEM WALL PAINTED ___LF. F-. -13 INSULATION NEW CLOSET ADDITION'I TO ALIGN W/ EXISTING REAR ELEVATION A2 SCALE:1/4" = 1'-0" 0 I 0 r 2"x4" BOTTOM PLATE 4" CONCRETE SLAB OVER VAPOR BARRIER ING SEE STRUCTURAL DRAWING 1/2" EXP. JOINT Z GROUT FILLED 8" CMU STEMWALL IDE HEAD CONT. CONCRETE FOOTING SEE STRUCTURAL DRAWINGS ADDITION WALL SECTION SCALE.3/4" = � SIDE ELEVATIO SCALE: 1/4" = T-0" NEW ROOF LINE TO MATCH EXISTI EXTERIOR FINISH TO MATCH EXI NEW CLOSET ADDITION TO ALIGN W/ EXISTING N A2 % 1E1 z LU U 0 00 muvr rL/-%INI (±) SCALE: 1/8" = T-0" ACCENT STONE - CHIMNEY STACK_ NEW ROOF LINE TO BE NEW ROOF LINE TO MATCH OVER -FRAMED & MATCH EXISTING EXISTING CLG. - 10'-0" - 7�-� '-0" OVER I KLj L� �—J \ -EXTERIOR FINISH \ TO MATCH \ EXISTING \ F.F. = 0'-0" — F.F. F.F. _ -411 - - - - - STEMWALL P""--- OMA NEW KITCHEN ADDITION TO ALIGN W/ EXISTING 20'-6" NEW OUTDOOR LIVING AREA ADDITION - VAULTED CEILING ACCENT STONE CHIMNEY STACK Al 12 CONFIRM 1 6 Z EXISTING I- EXISTING TO REMAIN L W z L bi MOVE EXIS ING U ENCH DO S Z RUCTURA O :'R IDE HEAD FOR NE 12' SLIDER OOR SIDE ELEVATION A2 SCALE: 1/4" = T-0" VAULTED T&G CEILING / Ajf OUTDOOR LIVING A L EA EXTERIOR FINISH TO MATCH EXISTING STEM WALL PAINTED TO MATCH NEW ADDITION TO ALIGN W/ EXISTING EXISTING TO REMAIN NEW CLG. = 10'-0" EXISTI = 8'-0" _IF. = 0'-0rr Julianne N. Overby, RA Architectural and Interior Design Julianne N. Overby, R.A. 2452 Pullian Street Jacksonville Beach, Florida 32250 904-704-8628 Email: jnoverby@att.net FL. AR -0017060 - FL. ID -4621 LIJ U M M Z ZN N W LLJ � J U) W ry W � wm =U z U) o Z C\1 00J O � Q DATE ISSUED: JULY 30, 2018 NOTE: DO NOT SCALE DRAWINGS. IF PRINTED ON 11 "X17" MEDIA, DRAWING SCALE IS HALF—SIZED. EXTERIOR ELEVATIONS AND DETAILS A2 PERMIT SET 1 �+ 27'-5" -------------------- :,je -------- 13'-0" 34'-4y2° EXISTING 18'-8/2 0 w w 140SF al D TACHE LA DDI 10 w o" Q111'-10" EXISTING I EXISTING DRIVE o I RESIDENCE ry I or_ w I CO II � w I z • I � I ~ I � w n II I 611SF a I ADDITION zz I IA LL I N . I � � 7J - Ir I I 1U EASEMENT — — — — — — — — — — — 35'-4'J — — — — — 15- 36'-9 SIDE PROPERTY LINE ARCHITECTURAL SITE PLAN SCALE: 1/16" = T-0" GARAGE F A3 SCALE: 114'' = 1'-0" RONT ELEVATION -------------------� m GARAGE FLOOR P 7L) SCALE: 1/4" = 1'-0" LAN B A3 GARAGE SIDE ELEVATION A3 SCALE:1/4" = T-0" fil 0" GARAGE REAR ELEVATION SCALE: 114" = 1'-0" 11 Julianne N . Overby,RA Architectural and Interior Design Julianne N. Overby, R.A. 2452 Pulhan Street Jacksonville Beach, Florida 32250 904-704-8628 Email: @o`rerby@att.net FL. AR -0017060 • F: ID -4621 w U (y) M Z Z N N w w cY) J Q � Ll.. U) D= W� C) W 0000� W m = U Z (/) c) �z z D C-'4 00J O � H DATE ISSUED: JULY 30, 2018 NOTE: DO NOT SCALE DRAWINGS. IF PRINTED ON 11 "X17" MEDIA, DRAWING SCALE IS HALF -SIZED. DETACHED GARAGE PLAN AND ELEVATIONS A3 PERMIT SET ii,AN.,-,, RESIDENTIAL ADDITION PERMITPERMIT NUMBER -, ': RESA18-0031 _ sj CITY OF ATLANTIC BEACH Vd v 4y- 800 SEMINOLE ROAD ISSUED: 12/21/2018 'rely' ATLANTIC BEACH, FL 32233 EXPIRES: 6/19/2019 2 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. 3 PUBLIC WORKS POST CONSTRUCTION TOPO SURVEY INFORMATIONAL Notes: If on-site storage is required,a post construction topographic survey documenting proper construction will be required. All water runoff must go to retention area and retention overflow must run to street. 4 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list(Advanced Disposal,Realco Recycling,Shapells,Inc.,Republic Services,Donovan Dumpsters, Phillips Containers). Container cannot be placed on City right-of-way. 5 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration,including sod,is required. 6 PUBLIC WORKS CONSTRUCTION SITE MANAGEMENT INFORMATIONAL Notes: Provide construction site management plan,including location of silt fence,dumpster,portable toilet. Right-of-Way Permit is required if using right- of-way for construction parking. 7 PUBLIC WORKS RUNOFF INFORMATIONAL Notes: All runoff must remain on-site. Cannot raise lot elevation. FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 455-0000-322-1000 0 $546.00 BUILDING PLAN CHECK 455-0000-322-1001 0 $273.00, BUILDING PLAN REVIEW RESUBMITTAL SECOND 455-0000-322-1006 0 $50.00 BUILDING PLAN REVIEW RESUBMITTAL THIRD 455-0000-322-1006 0 $75.00 PW REVIEW RESIDENTIAL BLDG 001-0000-329-1004 0 $100.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $14.16 STATE DCA SURCHARGE 455-0000-208-0600 0 $9.44 ZONING REVIEW SINGLE AND TWO FAMILY USES 001-0000-329-1003 0 $50.00 TOTAL: $1,117.60 Issued Date: 12/21/2018 2 of 2 ail-tv.r City of Atlantic Beach APPLICATION NUMBER J .. Building Department (To be assigned bythe BuildingDepartment.) '7A' `� 800 Seminole Road jj g p 2) s� Atlantic Beach, Florida 32233-5445 I- a S i s ` 000 ( Phone(904)247-5826 • Fax(904)247-5845 Q "'tow 9.' E-mail: building-dept@coab.us Date routed: 1 0/I it C City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: I '62- 0 I\1 , S h Etr Department review required Yes No uildin Applicant: coo „ C___ c\4•-ranning &Zoning Tree Administrator Project: '. d-cL '+i (fin Et i (11.1.:,relic Wor 'ublic Utilities_ Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District / Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. Denied. Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: /U c'9'/ 3" TREE ADMIN. Second Review: Approved as revised. enied. Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: 11-)S---/0 FIRE SERVICES Third Review: Approved as revised. ❑Denied. Not applicable Comments: Reviewed by: / f Date: f a -1 s'-'1 k Revised 05/19/2017 Doc # 2018299015, OR BK 18637 Page 1444 , Number Pages: 1, Recorded 12/21/2018 09:52 AM, RONNIE FUSSELL CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10.00 • �^ NOTICE OF COMMENCEMENT State of_ T lOr't uttt, Tax Folio No. 1120E0—0-116 County of ptal► 1,1 To Whom It May Concern: • The undersigned hereby informs you that improvements will be made to certain real property,and in accordance ith Section 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. _r Legal Description of property being improved: -t0 i pq 2 j_moi .".0 £ AI Ag-Iv Pr U 16 B Address of property being improved: I g20 .S/erry ' - V 1`x'4 32,12 3y ,4J t General description of improvements: c 7, •on I AL t �_��•��- I Owner: 1 �1� ' s Address: vg 1.1 S v'4 \r. Mkck _ Li,,,,�(:,�i L- Owner's interest in site of the improvement: a�•� 32223 Fee Simple Titleholder(if other than owner): Name: Contractor; C.flWse .Drvf't't{,rx-6 .tom. LI-C /Z Address: 14,x 9 !Cv- R/"e( ( 3,101-0-1 Telephone No.: 9O9` ?eife7 Fax No: Surety(if any) Address:. Amount of Bond$ Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: Address: I'ltone No: Fax No: Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name: Address: Telephone No: Fax No: In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER Signed: !•�. r Date:`G'8—/ , Before me this 144„ '.y of a in the County of Duval.State Of Florida,has personally appeared 5- Notary Notary Public ate,State laofjda,County of Dtry My commission expires: VIII 1 I' T/VlM/ Personally Known: ✓ or • Produced Identification: 4 4 Andrew D. Davis 1.04 , _COMM{SSKI#00241220 ,, EXPIRES:Sept.17,2022 It nt% Bonded lhru Aaron Notary 4 '. Building Permit Application Updated 12/8/17 City of Atlantic Beach .,. 800 Seminole Road,Atlantic Beach,FL 32233 `�`�, Phone:(904)247-5826 Fax:(904)247-5845 ` Job Address: 1 -r, _ t I ;p,V>� c CD` Permit Number: u'mLber. Description ,_47-Le 1 1 2"-`l� ` 1 UG of I�� U4�f lRE#�/�f -4-- Legal o'11t Valuation of Work(Replacement Cost)$ 12-11500. 0- Heated/Cooled SF 322 Non-Heated/Coop(d Two • Class of Work(Circle one): New lddition)Alteration Repair Move Demo Pool Window/Door • Use of existing/proposed structure(s)(Circle one): CommercialResidentia • If an existing structure,is afire sprinkler system installed?(Circle one): Yes No N/A • Submit a Tree Removal Permit Application if any trees are to be removed or Affidavit of No Tree Removal Describe in detail the type of work to be performed: ' tq°'717 f Q/ vr, ' r ,,- Florida Product Approval# for multiple products use product approval form Property Owner Information Name: c\. � +a4. L.NiCw�e Address: kg p 2-0 �ne 4-.N,V r, City ��pt.VL -) State CL. 322��j Phone 1 (clo RLS- 3i- - E-Mail 14Ai Cl ketl f epwalCotn Owner or Agdnt(If Agent,Pa r of Attorney or Agency Letter Required) Contractor Information C....40±-441-1- 4., , /.i Name of Company: 4t, O 4 � —'- X-C- Qualifying Agent: D 4.'r." Oh i. e,'\ Address ll. i S Lt.r'iC.o Rive( City 4..k, State - Zip 342ZO7 Office Phone Gib 61 ^ Li5t Job Site/Contact Number 6104-55j6- 9L(( 9 State Certification/Registration l SZ t 5O . E-mail -l+r;x.r. -# C a46...., • _ • '+.- Architect Name&Phone# J,4, Arnie-�t�Otw__-p_ vL{- 10Y-g 6A: Engineer's Name&Phone# V ( la. Tir1 oy - `112-1159 Workers Compensation OS 1/lelJ 1111 Criem-ply Insurer/Lease Employees/Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated.I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulationg construction in this jurisdiction.I understand that a separate permit must be secured for ELECTRICAL WORK,PLUMBING,SIGNS, WELLS,POOLS,FURNACES,BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc,NOTICE:In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT:I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. ' ./z` 41187( Signature of O er or A ) (Signat re of Contractor) (including contract r) Si ned nd sworn to(or affirmed)bef re me this �'�day of Signed andtesworn to(off affirmed)before me thi (1`-day of ZOIC' ,by?�. - _ t UCtUird l , . -1,D\�3 by B6 ain Ve l�Sit)(-\ �L C� ' 40.1 �{(Signature of Notary) Davis, ( n cure of Notary) (personally Known OR �.` C��'t, �i� AndrewD. DMt IV I ersonally Known OR [ 1 Produced Identificatio. ,a'c%COMMISSION#002412201 1 Produced Identification Type of Identification:-_- Type of Identification: EXPIRES:SBpt. 1fi;2022 AMY BETH aousH 1 Bonded Thru Aron Notary `� ir4r nm`,��� ,,. �:� •.. MY COMMISSION#FF 927559 -,. j f EXPIRES:February 14,2020 LN,, e.*..o ° Bonded Thnr Notary Public Underwriters Revision Request/Correction to Comments **ALL INFORMATION eri, HIGHLIGHTED IN r -� "' City of Atlantic Beach Building Department GRAY IS REQUIRED. t.11 800 Seminole Rd, Atlantic Beach, FL 32233 U11 9 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: 'Q` t-%--a) l Revision to Issued Permit OR IM Corrections to Comments Date: �2� L Project Address: IS 2-0 * Q k. IX¢ I J ' Contractor/Contact Name: 60°i?S& C-4-)i\-)T UN 6 / fiJ fi-i4 LAi L Contact Phone: CI 04 -S5(.0- 414(O9 Email: to,(1(La@ ccx.x- G-\ a_ (R (AD:1-N Description of Proposed Revision/Corrections: CD t IC c-tc-L S Ur1refoI J a- Wal- \ o►/N. SGS I ' -t W l LOP) affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) •_;lI-proposed revision/corrections add additional square footage to original submittal? No , _,Yes(additional s.f.to be added: ) n• proposed revision/corrections add additional increase in building value to original submittal? No F*Yes (additional increase in building value:$ ) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: �,/ (Office Use Only) 111 Approved ❑ Denied ❑ Not Applicable to Department Permit Fee Due. 1 7 5, 0 d Revision/Plan Review Comments Department Review Required: Building1 d_ Planning&Zoning Reviewed By Tree Administrator Public Works p� Public Utilities , / ) .-/8--/ O Public Safety Date Fire Services Updated 10/17/18 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 (904) 247-5800 BUILDING REVIEW COMMENTS Date: 11/28/2018 Permit#: RESA18-0031 Site Address: 1820 N SHERRY DR Review Status: denied RE#: 172020 0776 Applicant: COURSE CONTRACTING LLC Property Owner:YOUNG SARAH L Email: BRIAN@COURSECONTRACTING.COM Email: SALLYCLIFTONRD@GMAIL.COM Phone: 9045569469 Phone: 9048682377 THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: 1. Items #1 and #2 plan re iew c ments not met yet. Finish Floor Elevation and Product Approval Numbers without "R" v 1 C s-tBuilding 1 erna/led Pewit, cvn^ I- //- 2 g- IV- my Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with"clouding".The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud.The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with revisions shall be inserted into each set of drawings.The original sheets must be clearly marked "VOID" but are to be left within the set of drawings. Complete new sets of drawings will not be accepted.ADDITIONAL ITEMS MAY BE REQUIRED DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW. Revision Request/Correction to Comments **ALL INFORMATION HIGHLIGHTED IN .411hil City of Atlantic Beach Building Department GRAY IS REQUIRED. 800 Seminole Rd, Atlantic Beach, FL 32233 /I Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: 1Q---003) I Revision to Issued Permit OR I I Corrections to Comments Date: 111(9—I 1 g Project Address: 1 -2-0 DP- ov Contractor/Contact Name: COU CAD/Ni' jll/J E / LA.)t LCioi -J Contact Phone: h`k S ip-cp-i"tp' Email: 0610/1 COuare_CDA traCitifP chin Description of Proposed Revision/Corrections: COnstiurja,0( S i . ' i lar / r Sx Q�r �� �s� d i t ns ,,v( �g a ova mhz7, nr bu dtC ren cqs.c c air\ - Pie, -- Cit cna�oi e_ ptan s r , ircee affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) • ill proposed revision/corrections add additional square footage to original submittal? No I I Yes(additional s.f.to be added: 3 • . ill proposed revision/corrections add additional increase in building value to original submittal? I No I I*Yes (additional increase in building value: $ )(Contractor must sign if increase in valuation) *Signature of Contractor/Agent: (Office Use Only) ❑ Approved ❑ Denied ❑ Not Applicable to Department Permit Fee Du $ Revision/Plan Review Comments 1.1.evN 3 ` ('a -riven t i i Qv- Lv1...e7 npt--- Yep Department Review Required: Buildinfilr anning&Zoning. Reviewed By Tree Administrator is oiR) Public Utilities Public Safety Date Fire Services Updated 10/17/18 .I r\,`1 f !.-1 1 , CITY OF ATLANTIC BEACH '~ „ 800 SEMINOLE ROAD n1 _ m,_ j ;r ATLANTIC BEACH, FL 32233 (904) 247-5800 ✓�1119 '', BUILDING REVIEW COMMENTS Date: 10/29/2018 Permit#: RESA18-0031 Site Address: 1820 N SHERRY DR Review Status: denied RE#: 172020 0776 Applicant: COURSE CONTRACTING LLC Property Owner:YOUNG SARAH L Email: BRIAN@COURSECONTRACTING.COM Email: SALLYCLIFTONRD@GMAIL.COM Phone: 9045569469 Phone: 9048682377 THIS REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions submitted MUST respond to EACH department review. Submittals that respond to only one or a few correction items will not be accepted. Correction Comments: 1. Contractor shall submit a survey to show what the Finish Floor Elevation will be of the room addition. 2 copies. 2. Product approval numbers for items of the components and cladding that end in"R”values will not be accepted. The exact number,which may contain a decimal,needs to be submitted. You may have to /contact your supplier for the specific products that will be installed. 2 copies. (j From the 2017 6th Edition of the FBC-Existing Building, Residential, choose a method of construction compliance/alteration level. This information shall be placed on either the architectural drawings under BUILDING CODE SUMMARY, or on the structural drawings under DESIGN CRITERIA. 2 copies /needed of whichever is chosen. 2 copies of the construction site management plan is needed. This shall be placed in the job box for the building inspector and the Atlantic Beach Police Department. Building Mike Jones Building Inspector/Plans Examiner City of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233 904.247.5844 Email:mjoness@coab.us Etna Rev,e1✓ (oar r►^,ri 1f fo/Z9/'ai 4n/ Resubmittal Notes: IFF" F V PERMITTED BUILDING DATA DO NOT WRITE BELOW — OFFICE USE ONLY Applicable Codes: 6th Edition (2017) Florida Building Code DEVELOPMENT SIZE: Habitable Space (103),)- Space (ft2) LAND INFORMATION: Zoning District puB Flood Zone )( Minimum FFE yip Z BUILDING INFORMATION: Construction Type V Occupancy Group 5,1,sI-e Number of Stories Max Occupancy Load Fire Sprinklers Required CONDITIONS/ COMMENTS: Rev. 2.7.2018 01.a1y;.,r, City of Atlantic Beach APPLICATION NUMBER cls i4' ^< . Building Department (To be assigned bythe BuildingDepartment.) IC c 800 Seminole Road �� p ) �e) Atlantic Beach, Florida 32233-5445 I S ` OCD ( Phone(904)247-5826 Fax(904)247 5845 Q ''�arti ' E-mail: building-dept@coab.us Date routed: 1 0/i l 1 V City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: I D2- 0 h�.C('� Department review required Yes No _ ��� / A uildin Applicant: L-C) s,C� �, c4- 'l (\�. _Panning &Zoning d_.-CL CN❑ Tree Administrator Pro ect: lic Work i �� �'� �n G � 4��eta__ ublic Utilities Public Safety Fire Services Review fee $ Dept Signature j Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection ),. Florida Dept. of Transportation St.Johns River Water Management District /�S Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ,/pproved. ❑Denied. ❑Not applicable (Circle one.) Comments: • ChV 4..,0ce 2 Vifirz ( -Doi6 ( ' — ib') BUILDING PLANNING &ZONING Reviewed by: Date: '0-3 i — I g TREE ADMIN. Second Review: I Not applicable Approved as revised. Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ['Denied. fNot applicable Comments: Reviewed by: Date: Revised 05/19/2017 S�Lyj City of Atlantic Beach SCommunity Development Dept. l 800 Seminole Road j,of Atlantic Beach, Florida 32233 Telephone(904)247-5826 9;119',- http://www.coab.us Order of the Community Development Board APPLICANT: Sarah (Sally)Young and Mark Young 1820 North Sherry Drive Atlantic Beach, FL 32233 FILE NUMBER: ZVAR18-0016 DATE OF PUBLIC HEARING: September 18, 2018 ORDER APPROVING VARIANCE The above referenced applicant requested a variance as permitted by Section 24-64, to decrease the required side yard setback from 10 feet to 7.5 feet to allow for an addition and to decrease the side yard setback from 10 feet to 7.5 feet and to decrease the rear yard setback from 20 feet as required by Section III of the Selva Marina Unit 10-B Planned Unit Development to 6 feet to allow for a screen enclosure at Selva Marina Unit 10-B Lot 7 (aka 1820 North Sherry Drive). On September 18, 2018,a public hearing was held and said request was considered by the City of Atlantic Beach Community Development Board. Having considered the application, supporting documents and comments by staff, the applicant, and members of the public, the Community Development Board APPROVED, finding that the request is consistent with the provisions of Section 24-64(d) of the Land Development Regulations establishing grounds for approval of a variance and specifically the onerous effect of regulations enacted after platting or after development of the property or after construction of improvements upon the property. Appeals of a decision of the Community Development Board may be made to the City Commission by any adversely affected person(s).Such appeal shall be filed in writing with the City Clerk within thirty(30)days after rendition of this Order. The appellant shall present to the City Clerk a petition duly verified, setting forth that the decision being appealed is in conflict with or in violation of Chapter 24, Zoning, Subdivision and Land Development Regulations for the City of Atlantic Beach, in whole or in part, and specifying the grounds of the conflict or violation. The petition shall be presented to the City Commission within thirty (30) days after the filing of the appeal with the City Clerk. The undersigned certifies that the above Order of the Community Development Board is a true and correct rendition of the Order adopted by said Board as appears in the record of the Community Development Board minutes. DATED THIS DAY OF SEPTEMBER 2018. Shane Corbin Community Development Director Revision Request/Correction to Comments **ALL INFORMATION S HIGHLIGHTED IN #4GRA"' City of Atlantic Beach Building Department Y IS REQUIRED. UV 800 Seminole Rd, Atlantic Beach, FL 32233 /nI "' Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: )Z----003) fRevision to Issued Permit OR I I Corrections to Comments Date: 1)'(9-1 1 R Project Address: (-) 5-v-k l DR_ NI Contractor/Contact Name: At -r4i' .•.i►(V'1- •P ANI I CO IJ Contact Phone: 6)b Ss�p-6J4 /1 Email: orirt, C COU((2( tysoc.. ACC1/Y\ Description of Proposed Revision/Corrections: " ' plain / reivl_ce_d_ .Q.,x,r&ij v �ce c1 OCun.S �,v( i%ib,1 anovv3. mi2 // nUtiecd ( 1-(woo c4c( l� l z — �aC l ._ Ct_iy, (ncit._a e_. p tact s Rt ,>o mv'eL/ I affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) • ill proposed revision/corrections add additional square footage to original submittal? No 1 1 Yes (additional s.f.to be added: ) M 01{I 2 2013 • ill proposed revision/corrections add additional increase in building value to original submittal? No 11*Yes (additional increase in building value:$ ) (Contractor must sign if increase in valuation) *Signature of Contractor/Agent: (Office Use Only) /Approved ❑ Denied III Not Applicable to Department Permit Fee Due$ Revision/Plan Review Comments Department Review Required: (rBuildin anning&Zoning. Reviewed By Tree Administrator cPutllc of q Public Utilities //---7— 1 O Public Safety Date Fire Services Updated 10/17/18 0�Lvp;�e, City of Atlantic Beach APPLICATION NUMBER rY . Building Department (To be assigned by the Building Department.) ,� 800 Seminole Roadler ECIElvE. : I� t ��2 j �:,, r Atlantic Beach, Florida 32233 5445247- J Phone(904)247 5826 Fax(904) 5845 OCT 2 2O te routed: I F2)it X0109';' E-mail: building-dept@coab.us City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: I 2)2_ 0 h Err Department review required Yes No :uildin• Applicant: Co. Lse._ Co �4-r'c (\C Panning &Zoning Tree Administrator Project: F dcL +1 0A " q'4 eCq, lic wort ,C ublic Utilities__ Public Safety Fire Services Review fee $ Dept Signature , Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By dO. Florida Dept.of Environmental Protection Florida Dept.of Transportation -- St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. /Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed byje.Rier Date: TREE ADMIN. Second Review: 14proved as revised. Denied. pp n ( Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed b : /,i �% — , • I.te:e..;zp..,/,",,, ' FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 ,.SLA-N 1 A r CITY OF ATLANTIC BEACH ss Department of Public Works � ire) 1200 Sandpiper Lane J Atlantic Beach, FL 32233904 247-5834 �J,il< r� ( ) PUBLIC WORKS PLAN REVIEW COMMENTS Date: 10/25/18 Applicant: Course Contracting, LLC Permit It: RESA18-0031 Email: brianPcoursecontracting.com Review Status: DENIED Property Owner: Sally Young Site Address: 1820 Sherry Drive N. Email: sallycliftonrd@gmail.com THIS PLAN REVIEW IS ONE OF MULTIPLE DEPARTMENT REVIEWS Correction Items must be submitted to the Building Department at 800 Seminole Road. Submittals that respond to only one or a few correction items will not be accepted. Revisions may not be submitted until ALL departments have completed their respective reviews. Revisions must be submitted to the Building Department and must respond to EACH department review. PUBLIC WORKS CORRECTION ITEMS: • Provide construction site management plan including location of silt fence, dumpster, portable toilet. Right-of-Way Permit is required is using right-of-way for construction parking. • Provide drainage plans showing site topography (flow arrows, etc.). r, ; • Provide erosion and sediment control plans with installation details. i'.1 w' ' • Provide impervious surface calculations for entire lot (existing and post construction) `(-- 011.‘r) • Section 24-66(b) of the Land Development Regulations requires on-site storage for increased runoff if adding 400 SF or more impervious surface. Provide Delta volume calculations and on-site retention required per Section 24-66(b). • Provide a detailed plan of water retention area and how water runoff gets to water retention areas and then to street. PUBLIC WORKS CONDITIONS OF APPROVAL: (The following comments will be printed on your permit as Conditions of Approval) • Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact the Inspection Line (247-5814) to request an Erosion and Sediment Control Inspection prior to start of construction. • All runoff must remain on-site during construction. • If on-site storage is required, a post construction topographic survey documenting proper construction will be required. All water runoff must go the retention area and retention overflow must run to street. Page 1 of 2 O:\Public Works\ADMIN\PLAN REVIEW COMMENTS\RESA18-0031(Course Contracting).docx • Roll off container company must be on City approved list (Advanced Disposal, Realco Recycling, Shapells, Inc., Republic Services, Donovan Dumpsters, Phillips Containers). Container cannot be placed on City right-of-way. • Full right-of-way restoration, including sod, is required. • Provide construction site management plan including location of silt fence, dumpster, portable toilet. Right-of-way Permit is required if using right-of-way for construction parking. • All runoff must remain on-site. Cannot raise elevation. Scott Williams, Public Works Director swilliams@coab.us/904-247-5834 Resubmittal Notes: All revisions and changes shall clearly stand out from the rest of the drawing on the sheet as a revision by way of completely encircling the change with "clouding". The revision shall also be identified as to the sequence of revision by indicating a triangle with the revision sequence number within it and located adjacent to the cloud. The revision date and revision sequence number shall also be indicated in a conspicuous location in the title block for each sheet on which a revision for that sequence occurs. For projects still in the initial review stage and permit pending, all sheets with revisions shall be inserted into each set of drawings. The original sheets must be clearly marked "VOID" but are to be left within the set of drawings. Complete new sets of drawings will not be accepted. ADDITIONAL ITEMS MAY BE REQUIRED DEPENDING UPON NEW INFORMATION AND CLARITY OF FINAL PLANS SUBMITTED FOR REVIEW. Page 2 of 2 0:\Public Works\ADMIN\PLAN REVIEW COMMENTS\RESA18-0031(Course Contracting).docx Revision Request/Correction to Comments **ALL INFORMATION s Ts�L�;/• s HIGHLIGHTED IN • -. # "' City of Atlantic Beach Building Department GRAY IS REQUIRED. s ''d 800 Seminole Rd, Atlantic Beach, FL 32233 `ono Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#:P.:Sit )Q--008/ fl Revision to Issued Permit OR El Corrections to Comments Date: 11 -1 l g Project Address: R) GIPKP- i DI2— NJ Contractor/Contact Name: 0 C2-r41' ,/�►iit"1- ♦ L J ANI 1 Sorb Contact Phone: q "k 56L+1/1 Email: OrIaI CO(J'as-e(DA trete .c Description of Proposed Revision/Corrections: t aff\ / reiviskd Q,JY-,[ 10 v tc 0d tun_ �,0( S ? ova rD 11 nr u d ( -(r),,voc4s,c, t, ploiy-\ Z - CcL_C, -- Ciha (nckae_. p�ai FAr Thvrv'e4 I affirm the revision/correction to comments is inclusive of the proposed changes. (printed name) • ill proposed revision/corrections add additional square footage to original submittal? No n Yes(additional s.f.to be added: ) NOV 2 1 2018 • ill proposed revision/corrections add additional increase in building value to original submittal? No F1*Yes (additional increase in building value:$ )(Contractor must sign if increase in valuation) *Signature of Contractor/Agent: (Office Use Only) 4roved ❑ Denied ❑ Not Applicable to Department Permit Fee Due$ Revision/Plan Review Comments Pans 1i' lay* -t Lark-C-ici►e, Department Review Required: (Buildin ,......-/) 1/144Z- annin &Zoni Reviewed �2 Tree Administratno� ������ y _ is or<s Public Utilities NOV Z 1 ZO1S // -024°10 Public Safety BY: `( Date r✓ Fire Services Updated10/17/18 #4 t Comp. By: S/W r) Date: 11/28/2018 Public Works Department City of Atlantic Beach Permit No: RESA 18-0031 Address: 1820 North Sherry Drive Required Storage Volume Criteria: Section 24-66 of the City of Atlantic Beach's Zoning, Subdivsion, and Land Development Regulations requires that the difference between the pre-and postdevelopment volume of stormwawter runoff be stored on site. Volume of Runoff is defined as follows: V=CAR/12 Where: V=Volume of Runoff C=Coefficient of Runoff A=Area of lot in square feet R=25-yr/24-hr rainfall depth(9.3-inches for Atlantic Beach) Predevelopment Runoff Volume: Lot Area(A) = 9,078 ft2 Runoff Coefficient Area Lot Area Description (ft2) (ft2) "C" Wtd"C" Impervious 3,380 9,078 1.00 0.37 Pervious 5,698 9,078 0.20 0.13 Runoff Coefficient(C)= 0.50 Runoff Volume V= 0.50 x 9,078 x 9.3 / 12 V= 3,503 ft3 Postdevelopment Runoff Volume: Lot Area (A) = 9,078 ft2 Runoff Coefficient Area Lot Area Description (ft2) (ft2) "C" Wtd"C" Impervious 3,991 9,078 1.00 0.44 %ISA= 44.0% Pervious 5,087 9,078 0.20 0.11 Runoff Coefficient(C)= 0.55 Runoff Volume V= 0.55 x 9,078 x 9.3 / 12 V= 3,882 ft3 Required Storage Volume DV= Postdevelopment Runoff Volume-Predevelopment Runoff Volume DV= 3,882 - 3,503 DV= 379 ft3 Retention MASTER WATER RETENTION 11/28/2018 r ii1 Comp. By: S/W • Date: 11/28/2018 0-ffsoze) Public Works Department City of Atlantic Beach Permit No: RESA 18-0031 Address: 1820 North Sherry Drive Provided Storage: Elevation Area Storage (ft) (ft2) (ft3) Right Side 13.0 80 0 BOTTOM size 20 X 4 13.5 200 70 TOB size 25 X 8 Elevation Area Storage (ft) (ft2) (ft3) Left Side 13.0 152 0 BOTTOM 19 X 8 13.5 500 163 TOB 25 X 20 Elevation Area Storage (ft) (ft2) (ft3) 0.0 0 0 BOTTOM 0.0 0 0 TOB Inground storage=A*d*pf A=Area= 700.0 d=depth to ESHWT= 10.5 pf=pore factor= 0.3 Inground Storage= 2205.0 ft3 Required Treatment Volume= 379 ft3 Supplied Treatment Volume= 2,275 ft3 Retention MASTER WATER RETENTION 11/28/2018 CGC1521502 COURSE C O N T R A C T I N G C:s1E: N.1 BiJ # L. CD I IR. EMC:1 co Treat others how you would want to be treated! Respect the neighbors. Respect the work of other Trades. This property will be around for you to drive your grandchildren by and tell them you built this! Construction is a noble profession;take pride in what you are doing! "When we build,let us think that we build forever. Let it not be for present delight,nor for present use alone;let it be such work as our descendants will thank us for." -John Ruskin, 1849 • SAFETY FIRST!Think and focus on what you are doing.The safest way is not always the quickest or easiest way of doing work, but it is the only way if you want to go home in the same condition you arrived.Your family and friends need you. • All material and debris to be kept off the streets. Look for garbage in the streets and ensure worksite is clean each day. • Drugs and alcohol will not be tolerated on site before, during or after working hours.Violators will be terminated. • Smoking is prohibited on this property at all times. If you need to smoke you must be in your vehicle on the street. • Absolutely no activity before 7:00 a.m. or after 7:00 p.m. unless authorized by Course Contracting. This means no saws, radios or yelling. NO WORK ON SUNDAYS. • Jobsite cleanup is mandatory daily and the responsibility of each vendor and/or contractor. This includes disposing of all soda cans, cups and lunch trash. Let's maintain a clean and orderly jobsite that is broom swept before the next trade arrives. • All contractors are responsible for complying with OSHA regulations. Personal Protective Equipment(PPE) is required and is the responsibility of each vendor and/or contractor. • Close and lock all doors and windows before leaving. • Jobsite theft will be prosecuted. • Refer all owner or neighbor questions or comments to Course Contracting personnel. t..,1404,4 RIGHT-OF-WAY/ EASEMENT PERMIT APPLICATION **ACL INFORMATION Y City of Atlantic Beach HIGHLIGHTED IN GRAY IS J 800 Seminole Road,Atlantic Beach, FL 32233 REQUIRED. PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES I 2 Job Address lg� lQ 5 Ft t -nlI "�,,.j) rfl Ci fPC t i(I, Permit Number e.L�A I.'-�31 75-Li3`) Contractor Information Company COU P- L PvC'CTh b Qualifying Agent 11 W 1L'S(',ANJ Address 1p` .'\ SPc &AN-0-co \ City j.p,C.1(- JV \Lkr State `rt.-- Zip '1-32-7-0-7 Phone 104- tPi 2.-9-94- Email I've if o e cc c-sr,4';4 t(i fl R .cx>` , State Certification/Registration#Ctil riCall'.< Ikt2?,' C&7/ 1` 2. s I-- c6 1.-10, X 00$3 Architect AA�� Phone Li-V- 0, Email /y Engineer 4—VVit• i`1 �� Phone 6�`�- +V /L/ / Email -IN -tv1ri.r-�7h 'i'"(��1�`l Workers Compensation Insurer ✓. t. OR Exempt xpiration Date 5�4% !19 P • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities,both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction, repair, improvement,maintenance,safe and efficient operation,alteration or relocation of all,or any portion of said street or easement as determined by the Public Works Director,any or all said poles, wires, pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said street or easement or reset or relocated hereon as required by the Public Works Director and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet ty of Atlantic each or Florida Department of Transportation Standards and be performed under the supervision of a,. W/Sem (Project Superintendent) with(Company Name) Co cSC. 'Ccx-k---A.-�=f Ag Phone` 904/-s56—'74/ • All materials and equipment shall be subject to inspection by the Public Works Director. • All city property shall be restored to its original condition as far as practical,in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • The permittee shall commence actual construction in good faith within -CO days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Public Works Director to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right, title and interest in the land to be entered upon and used by the holder,and the holder will,at all times,assume all risk of and indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of ex enses arising i r .• y manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. • e Pkbl' o rector shall be notified 24 hours prior to starting work and again immediately upo com letion. _� Date lb 2/ /f �. Permittee(signed in presence of Notary Public) STATE OF FLORIDA,COUNTY OF DUVAL -}- The foregoing instrument was acknowledged this �'L' ` day of �� � ,20 1 b , by cbc-\ keN1\L, \`Jl ,who personally appeared before me and (printed name of Permittee) Ip;+ry;'•., AMY BETH ROUSH acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. • MY COM:February 14,2 59 r'..% ..:a EXPIRES:February 14,2020 f 2 'T:o1:ry?f` Bonded litre Notary Public Urderwnters '1 1.2( ,�1 ersonally Known Signatture of Notar Pu lic,State of F arida [ ]Produced Identification(Type) H:\Applications&Forms\Word Documents\201801001 Right-of-Way Easement Permit Application.docx Revision Date:10/1/18 ;S�-vy jy, City of Atlantic Beach APPLICATION NUMBER `as A �, Building Department (To be assigned by the Building Department.) ';� � 800 Seminole RoadE'VE 400) ;, Atlantic Beach, Florida 32233-5445 Rl � ' Phone(904)247-5826• Fax(904)247-5845 / '40100. E-mail: building-dept@coab.us OCT 2 4 20'3 Ute routed: 1 0I p) City web-site: http://www.coab.us BY: - APPLICATION REVIEW AND TRACKING FORM Property Address: I 52. 0 1\1 , h e. rk-r Department review required Yes No A uildin Applicant: CCS 0 (--se__ Co -1-1' (v� Panning & Zoning NTree Administrator Project: i d_cL 4 I ofi Ipf 9'-1-etq, lic Worl ,public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By ,, Florida Dept. of Environmental Protection Florida Dept. of Transportation 4.-- St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. I 'Denied. I of applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: /0-70--/eK.- TREE ADMIN. Second Review: A roved as revised. I 'Not applicable ❑ pp ['Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. I INot applicable Comments: Reviewed by: Date: Revised 05/19/2017 Ik FIC CO j I LOT 6 LOT 3 t f'•, I SET 1/I SETOO0 10.0' N89°10'2TE 94,62' �t(7 LBir S 30,0' I LB#7893 �1; rT .. elt 02 --; 1 4 A/C A/C TZ ' �'.. 140SF A ' 13'0" 18.4' ., •� DETACHED% I �o, 34,0' E�1 na.r ; 1.) .'-0" 10,"0„ o 13.0' _ CONCRETE : .' .:' . ----� i w EXISTING ,:••:..-,. •t.- *•' 1 Z P.H. o: RESIDENCE `. . Ill :11. ME ' BUILDING 12.0'NC ,: 3.4' #1820 004' - '.'.'LOT 2 4 it < m' ;:., l WOOD I' `4T ,+ °i: - DECK (ll LOT COVERAGE: 4 32.3' 0 � :._:::::-5.. p �'.,:-{ o ,"� TOTAL LOT 9,079 S.F. I II 0 ' i�►� WINDOW d ' _ a O EXISTING HOUSE 2,027 S.F. ,-v-�,� r o° 1 I NOOK } NEW ADDITIONS 830 S.F. _ w 1 2 EXISTING DRIVEWAY 499 S.F. ,I�„I// f ' • FRONT PORCH BWALK611SF 20' 50' fn ` s EXISTING PADS 46 S.F. rtj�l�Wv, •DDITION 8.4' $ :'. TOTAL IMPERVIOUS 3,402 S.F. „41„ ' (37.5%) ` I �Ap° '.., I N PAVERS PATIO 429 S.F. ,m .� 2� TOTAL WITH PAVERS=3,831 S.F. I? �?/ m Ir y,: (42%) I 1 O I 1 --_ I �10 EASEMENT / 8 1 1' - as'-oma 5'U.E. — 30.00' _ FOUND 1/P'.1' '" 1.OSR9 • EET 12' ;,= IRON PIPE LOT 1 LOT 8 1 J SURVEY NOTES CONCRE7 E UKIVE CROSSING THE PROPERTY UNE ON EASTERLY SIDE OF LOT. THERE ARE FENCES NEAR THE BOUNDARY OF THE PROPERTY AND CROSS INTO THE ' PERMANENT 5'U.E.ON SOUTHERLY SIDE OF LOT,AND THE PROPERTY LINE ON NORTHERLY AND SOUTHERLY SIDE OF LOT. I CONTROL 6' POINT TARGET W No.8415 F SURVEYORS CERTIFICATE t IHEREBY CERTFYTHAT THISBDUNGMtYSURVEY SURVEYING,LLC c IS A TRUE AND CORRECT REPFESBITATDN OF A a SURVEY PREPARED UNDER MY DIRECTION. . NOT VAUDWITHOUT ANAUDE RICATTDE ELECTRONIC LB#7893 ', STATE OF .� SIGNATURE ANDAUTHENDCATEDDECTRONCSEM, °,�, LORI o� °RARAISED AL1O "A""'E SERVING FLORIDA '°"'`r 6250 N.MLITARY TRAIL,SUITE 102 N O V 2 1 2018 WEST PALM BEACH,R.33407 PHONE(561)640.4800 44...L3-, Construction Site Management Plan Checklist r-,*\' City of Atlantic Beach Building Department j j 800 Seminole Rd, Atlantic Beach, FL 32233 -T_ ' Phone: (904) 247-5826 Email: Building-Dept@coab.us A construction site management plan conforming to the City of Atlantic Beach Code of Ordinances Sec. 6- 18 must be included with every permit. An approved Construction Site Management Plan must be posted on the job site and available for review. The Co truction Site Management Plan must include the following information: The Parking plan: Parking plan showing how site will be accessed and all onsite and abutting street parking areas. Location of construction trailers, loading/unloading area, and material storage area. 3. Location of chemical toilet area: Chemical toilets must be kept out of the City right-of-way and not further than 15 feet from structure under construction., ati\ShAfLQ D,C9Cl�g d be"- w� 4. Location of dumpster: Dumpster must be from a City-approved waste company, in accordance S with Chapter 16 of the City of Atlantic Beach Code of Ordinances. Dumpsters are to have tarp covers or rigid covers on windy days. Dumpsters must be removed prior to issuance of Certificate of Occupancy or Certificate of Completion. 5. Traffic control plan, showing access with dimensions, area to be st bilized, narrative on phasing of construction with adequate parking and delivery of materials. l� —to ' ( O{- l p --to NeLeW c - 6. Site cleanliness: Contractor must have the entire construction site cleaner by Friday 6f each week. This means removal of scrap lumber, concrete remnants, and other such construction debris including cans, metal, plastic, and paper. S'e CLACkaulct tjcA9s0e, ralLO 7. Erosion and Sediment Control: Contractor must maintain all elements of the approved Erosion & Sediment Control Plan (silt fence, catch basin filers, etc.) until sod or other stabilization has been placed and approved by Public Works. -Q 8. Other activities, where special conditions are identified by the Building Official. Failure to comply with the Construction Site Management Ordinance may result in a Stop Work Order being issued in accordance with City of Atlantic Beach Code of Ordinances Sec. 6-17 (b)(3). Updated 10/9/18 flFFICF COPY FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1820 Sherry Dr N Builder Name: Course Contracting Street: 1820 Sherry Dr N Permit Office: City,State,Zip: Atlantic Beach,FL,32233 Permit Number: Owner: Jurisdiction: 261300 Design Location: FL,Jacksonville County: Duval(Florida Climate Zone 2) 1. New construction or existing Addition 9. Wall Types(269.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=13.0 269.33 ft2 b.N/A R= ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms(Bedrms In Addition) 0(0) d.N/A R= ft' 10.Ceiling Types (322.0 sqft) Insulation Area 5. Is this a worst case? No i a.Under Attic(Vented)✓ R=30.0 322.00 ft2 6. Conditioned floor area above grade(ft2) 322 J b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(12.0 sqft.) Description Area a.Sup:Main,Ret:Main,AH:Main 6 64.4 a. U-Factor: Dbl,U=0.31 12.00 ft2 SHGC: SHGC=0.19 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 30.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 30.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.190 14.Hot water systems-Replacement equipment 8. Floor Types (322.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.930 a.Slab-On-Grade Edge Insulation R=0.0 322.00 ft2 b. Conservation features b. N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.037 Total Proposed Modified Loads: 7.97 PASS Total Baseline Loads: 8.64 I hereby certify that the plans and specifications • covered by Review of the plans and ,.•0i•1;N............. .,• this calculation are in compliance with the Florida Energy specifications covered by this .'ti.: n-� ;...',.44:4-:**-..'••.' =...•• . s Code. calculation indicates compliance .,,,°'%•';•' c with the Florida Energy Code. i n,,,, °- :;;., ,;;O • Tim Isparyan r w `1 , PREPARED BY: Before construction is completed c -- - ,oro„s i CA 1 .i 0 : DATE: -_____ this building will be inspected for i 0 ! i_ ::,a compliance with Section 553.908 .''•. ' I herebycertifythat this buil.'-. as d-sig -d, is in compliance Florida Statutes. • u 9 P with the Florida EnergyC. •• CO. W. Ilik -• AI) - 4/ OWNER/AGEN : �- BUILDING OFFICIAL: // DATE: n r DATE: J__a S /__ - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2). 10/12/2018 4:43 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 1820 Sherry Dr N Bedrooms: 0 Address Type: Street Address Building Type: User Conditioned Area: 322 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Course Contracting Rotate Angle: 0 Street: 1820 Sherry Dr N Permit Office: Cross Ventilation: County: Duval Jurisdiction: 261300 Whole House Fan: City,State,Zip: Atlantic Beach, Family Type: Single-family FL, 32233 New/Existing: Addition Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp �/ Design Location TMY Site ,/ 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE_INT" 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block1 322 2576 SPACES Number Name Area Volume Kitchen Occupants Bedrooms lnfil ID Finished Cooled Heated 1 Main 322 2576 Yes 0 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 33.8 ft 0 322 ft2 ___ 0.7 0.3 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 349 ft2 0 ft2 Medium N 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 322 ft2 N N CEILING V # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 322 ft2 0.11 Wood 10/12/2018 4:43 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 4 • FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below V.#_—Ornt_.--__T�- ___WalLiype Space R,Value_- FS--_ An___ F_t_—In Area —_ R-Value_Fraction_ Absor.-_Grade% . _ 1 W Exterior Frame-Wood Main 13 15 10 8 126.7 ft2 1 0.2 0.75 0 2 N Exterior Frame-Wood Main 13 17 10 8 142.7 ft2 0.2 0.75 0 DOORS V # Ornt Door Type Space Storms U-ValueWidth Height Area Ft In Ft In 1 N Insulated Main None .65 3 6 8 20 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 2 Vinyl Low-E Double Yes 0.31 0.19 N 12.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None GARAGE V # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 382.8 ft2 382.8 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 214.7 11.78 22.16 .0956 5 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/Existing/c None HSPF:8.2 30 kBtu/hr 1 sys#1 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/Existing/confinne None SEER:14 30 kBtuihr 900 cfm 0.75 1 sys#1 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.93 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 10/12/2018 4:43 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 4 • FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Main 6 64.4 ft2 Main 16.1 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb ' Mar ' Apr Mayn Jun Jul 7C AugX]SepOct [ ]Nov Dec HeatinX Jan X Feb X Mar pr t MaJun rl Jul Au [ ]SeOct [X]Nov X Dec Ventin Jan Feb X Mar X`A r [ Ma Jun Jul ' ' Aug [ ]Sep 'X Oct [XJ Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 Main 10/12/2018 4:43 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 92 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. Addition 12. Ducts, location&insulation level a)Supply ducts R 6.0 2.Single-family or multiple-family 2. Single-family b)Return ducts R 6.0 c)AHU location Main 3. No. of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 0 13.Cooling system: Capacity 30.0 a)Split system SEER 5. Is this a worst case? (yes/no) 5. No b)Single package SEER c)Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 322 d) Room unit/PTAC EER e)Other 14.0 7.Windows, type and area a)U-factor:(weighted average) 7a. 0.310 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.190 14. Heating system: Capacity 30.0 c)Area 7c. 12.0 a)Split system heat pump HSPF b)Single package heat pump HSPF 8.Skylights c) Electric resistance COP a)U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other 8.20 9. Floor type, insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood, raised (R-value) 9b. 15.Water heating system c)Concrete, raised (R-value) 9c. a) Electric resistance EF 0.93 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. 13.0 e)Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. f)Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame(Insulation R-value) 10B1. 2. Masonry(Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a)Ceiling fans a) Under attic 11a. 30.0 b)Cross ventilation No b)Single assembly 11b. c)Whole house fan No c)Knee walls/skylight walls 11c. d)Multizone cooling credit d) Radiant barrier installed 11d. No e)Multizone heating credit f)Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded)in this home before final inspection. Otherwise,a new EPL display card will be compl based on i stalled code compliant features. BuilderSignatur Date: /// 114/i> Address of New Home: 1820 Sherry Dr N City/FL Zip: Atlantic Beach, FL 32233 10/12/2018 4:43:38 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: 1820 Sherry Dr N Permit Number: Atlantic Beach,FL,32233 MANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL ❑ R401.3 Energy Performance Level(EPL)display card(Mandatory)The building official shall require that an energy performance level(EPL)display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law(Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. ❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. LI R402.4.1 Building thermal enveldlinE building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 InstallationThe components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7), Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. ❑ R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. ❑ R402.4.3 Fenestration air leakagdNindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 L/s/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 L/s/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 10/12/2018 4:43 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) 0 R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. D R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. n R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or (7), Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i), Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. ❑ R403.3.3 Duct testing(Mandatory).Ducts shall be pressure tested to determine air leakage by one of the following methods: 1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manuf air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. LIR403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)or below 55°F(13°C)shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory)Heated water circulation systems shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. 111R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. ❑ R403.5.1.2 Heat trace systems.Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 10/12/2018 4:43 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) ❑ R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies(Mandatory). ❑ R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). ❑ R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be tumed off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of combustion types of service water-heating systems to be turned off. ❑ R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation, Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. • R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation including: Natural, Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole-house mechanical ventilation system fan efficacy.When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. ❑ R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10 otherwise. R403.7 Heating and cooling equipment(Mandatory). ❑ R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMUM (CFM) (CFM/WATT) (CFM) Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom,utility room 10 1.4 cfm/watt <90 Bathroom,utility room 90 2.8 cfm/watt Any For SI: 1 cfm=28.3 L/min. a. When tested in accordance with HVI Standard 916 10/12/2018 4:43 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing. Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. ❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. ❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. ❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. ❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. ❑ R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8°C). ❑ R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. ❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. ❑ R403.10.2 Time switches.Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. ❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal Elefficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 10/12/2018 4:43 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 5 • ❑ R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. ni R403.11 Portable spas(Mandatorfle energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS 0 R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception:Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory)Fuel gas lighting systems shall not have continuously burning pilot lights. 10/12/2018 4:43 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 5 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: 1820 Sherry Dr N Builder Name: Course Contracting Street: 1820 Sherry Dr N Permit Office: City,State,Zip: Atlantic Beach,FL,32233 Permit Number: Owner: Jurisdiction: 261300 w Design Location: FL,Jacksonville U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit Ceiling/attic insulation and anygaps in the air barrier shall be sealed. 9 P shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind oioina and wirina. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover elates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 10/12/2018 4:43 PM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 1 Level 1 8" Existing Home is 593 dm Kitchen"dito ®85 cxF:3 85 deg7 85 cf;® 85 df.P 85 car 85 cpm Jdm IrMIIIIIMMI11111.111.111.11.211.11mmil Garage Room3 - Job#: Avalon Heating and Air Scale: 1 :95 Performed for: Page 1 Course Contracting 3665 Spring Park Rd RightSuite®Universal 2017 1820 Sherry Dr N Jacksonville,FL 32207 17.028 RSU23882 Jacksonville, FL 32233 Phone:9042451818 2018-Oct-1217:04:35 Prged1.rup www�cavabnac.com 4- Duct System Summary Job: wrightsoft Date: Oct 12,2018 Entire House BY Avalon Heating and Air 3665 Spnng Park Rd,Jacksonville,FL 32207 Phone:9042451818 Web:wwwavalonac.com License:CMC1249968 Project Information For: Course Contracting 1820 Sherry Dr N,Jacksonville,FL 32233 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.19 in H2O 0.19 in H2O Available static pressure 0.31 in H2O 0.31 in H2O Supply/return available pressure 0.155/0.155 in H2O 0.155/0.155 in H2O Lowest friction rate 0.340 in/100ft 0.340 in/100ft Actual airflow 593 aril 593 c$n Total effective length(TEL) 91 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) WI) (dm) FR (in) (in) Mali Ln(ft) Ln(ft) Trunk Existing Home C 3608 77 85 0 0 Ox 0 VIFx 0 0 Existing Home-A C 3605 77 85 0 0 Ox 0 VIFx 0 0 Existing Home-B C 3605 77 85 0 0 Ox 0 VIFx 0 0 Existing Home-C C 3605 77 85 0 0 Ox 0 VIFx 0 0 Existing Home-D C 3605 77 85 0 0 Ox 0 VIFx 0 0 Existing Home-E C 3605 77 85 0 0 Ox 0 VIFx 0 0 Kitchen Addition h 5917 134 86 0.340 8.0 Ox 0 VIFx 21.2 70.0 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfrn) (din) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk • rb1 Ox 0 593 593 0 0 0 0 Ox 0 VIFx 2018-Oct-12 17:04:09 � wrightsoft Right-Suite®Universal 2017 17.028 RSU23882 Page 1 ACCP, Projectl.rup Calc=MJ8 Front Door faces: E OFFICE COPY APPROVAL INFORMATION SHEET FOR THE CITY OF ATLANTIC BEACH FLORIDA (*REQUIRED) PRL, 1f c J jve Permit It -E- A I 5 — 0031 *Project Address: 54.1/ your *Owner/Project Name Asrbequired by Florida Statute 553.842 and Florida Administrative Code Rule 9B-72, please provide the information and product approval number(s)for uild�r,g components listed below as applicable to the building construction project for the permit number listed above. You should contact your the product supplier if you do not know the product approval number for any of the applicable listed products. Information regarding statewide product approval may be obtained at: www.floridabuilding.org. Category/ Subcategory Manufacturer Product Description Limitation of Use State# Local# A.EXTERIOR DOORS }S 1.Swinging nn� ��t 'jr -C)9 2.Sliding _ 3.Sectional 4.Garage Roll-Up 5.Automatic 6.Other B.WINDOWS 1.Single hung JP.1n( tie, 144ows f24 2.Horizontal slider 3.Casement 4. Double hung 5. Fixed 6.Awning 7. Pass-through 8.Projected 9.Mullion 10.Wind breaker 11.Dual action 12.Other Page 1 of 4 Updated 10/17/18 Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# C. PANEL WALL 1.Siding Ju //-Arte e , 1447 5 d:..a _ � `� �—i . l 2.Soffits i 3. EIFS 4.Storefronts 5. Curtain walls _ 6.Wall louvers 7.Glass block 8. Membrane 9.Greenhouse 10.Synthetic stucco 11.Other D. ROOFING PRODUCTS 1.Asphalt shingles GAF teIrc �Ga[ isrti lef futoot4 ' 2. Underlayments 3. Roofing fasteners 4. Nonstructural metal roof 5. Built-up roofing 6. Modified bitumen 7.Single ply roofing 8. Roofing tiles 9. Roofing insulation 10.Waterproofing 11.Wood shingles/shakes 12. Roofing slate 13. Liquid applied roofing 14.Cement-adhesive coats 15. Roof tile adhesive 16.Spray applied polyurethane roof 17. Other Page 2 of 4 Updated 10/17/18 Category/Subcategory Manufacturer Product Description Limitation of Use State# Local# E.SHUTTERS 1.Accordion 2. Bahama 3.Storm panels _ _ 4.Colonial 5. Roll-up _ 6. Equipment 7.Other F.STRUCTURAL COMPONENTS 1. Wood connector/anchor 2.Truss plates 3. Engineered lumber 4. Railing 5.Coolers-freezers 6.Concrete admixtures 7. Material 8. Insulation forms 9. Plastics 10. Deck-roof 11.Wall 12.Sheds 13. Other G.SKYLIGHTS 1.Skylight 2.Other H. NEW EXTERIOR ENVELOPE PRODUCTS 1. 2. Page 3 of 4 Updated 10/17/18 In addition to completing the above list of manufacturers, product description and State approval number for the products used on this project, the Contractor shall maintain on the job site and available to the Inspector, a legible copy of each manufacturer's printed specifications and installation instructions along with this Product Approval Sheet. I certify that this product approval list is true and correct to the best of my knowledge. I further certify that use of different components other than the ones listed in this document must be approved by the Building Official. *Contractor Name (Print Name): 4''1 *Contractor Signatuc: . • *Company Name: U. i2 *Mailing Address: /'402( Ste. /14fc-; 8/v/"( LJ ve *City: Tc *State: *Zip Code: .? 7 *Telephone Number: ?pc( 642- '/3V4-7 *E-mail Address:- - C ce c ,- i --c is- • c Cell Phone Number: '"V S5 C- 96(6 , Fax Number: Page 4 of 4 Updated 10/17/18 BOUNDARY SURVEY LOT 3 LOT 6 SET VT SET 1%1' IRKS 11, off N89°10'2TE 94.62' _413 ♦ 30.0 1 ----- 02 1 A - - ---- 1 = o NC AC Q- 1 U i1 140SF b% I 13_° -- _ 182 V) D TACH: I'I I _` ' rn •'-o'OEM o' 13.0' CONCRETE _ 'i P.H.t a EXISTING •. '" '. ^: 1 Z RESIDENCE 120' I O 3.4 BUILDING 7 •• �'' 2) _ #1820 1 ° 'I W Q •, - WOOD I 42 DECK II 7. i sn LJ i s. O. • I O 'C I j WINDOW +,.,.,.;..,:_ ' a 0 II / _. r1�NOOK . '- 611 SF o, 20, 0' 441&411 ADDITION 6.4 N Is'�II / 4. s N iA m 02 I1 1d EASEMENT ___ 8. I b _.1' 36.1 ° ♦ 5'U.E. 1° 30.00 FOUND 1%2' t,1 — 06g9AIf I lE SET 1,7 IRON PIPE IRON ROD LOT 1 LOT 8 LB#7893 COMMUNITY DEVELOPMENT APPROVED 7i SURVEY NOTES iL $ CONCRETE DRIVE CROSSING THE PROPERTY LINE ON EASTERLY SIDE OF LOT. THERE ARE FENCES NEAR THE BOUNDARY OF THE PROPERTY AND CROSS INTO THE ' PERMANENT 5'U.E.ON SOUTHERLY SIDE OF LOT,AND THE PROPERTY LINE ON NORTHERLY AND SOUTHERLY SIDE OF LOT. ICONTROL POINT 1 ft P J,F 0-1- ...7,1-1:40. .e4� C wa SURVEYORS CERTIFICATE RGET ■ I HEREBY CERTIFY THAT THIS BOUNDARY SURVEY IS PREPARE) OF A SURVEYING,LLC NOT VALID N?THOUT AN AUTIENTICAT®BECIROMC #7893 ''°+,.1 • iA 'OF •a SIGNATURE AND AUTHENTICATED ELECTRONIC SEN, LB °ti.Ion 1 0 °� ORA RAISED EMBOSSED SEAL NO SIGNATURE E, SERVING FLORIDA 6250 N.MLITARY TRAIL,SUITE 102 WEST PALM BEACH,FL 33407 PHONE (561)640.4800 (SIGNED)- � STATEWIDE PHONE (800)226-4807 KENNETH J OSBORNE tr�PGDMeNagiS1 h�. STATEWIDE FACSIMILE(800)741-0576 PROFESS MAL SURVEYOR AND MAPPER 06415 n WEBSITE http targetslmByig.net 0 I LOT 6 LOT 3 SET 1/1'ON ROD I �B 1, 0•a N89°10'22 E 94.62 „ �1.a LLRB 301 ....-•:`j,:. 1 02 A A liFill= o AIG AIG a� 140SF bl / 13'-0' (in 18.4' DETACHED'I 79SF , o>, 34.0 _ -0G,to 11 ;$ 3RO 10'NN� CONC IF^ • -A Iw k. , SPH EXISTING II �°4 RESIDENCE 120 '- ^ 3.4 BUILDING --r?-;.:..s.. / :•:-•::'.'-:- •:::',..-:::-.. 1 LOT 2 a ° - NUOD 1 `4 LOT COVERAGE: 11 32.3' T Q `: •, I -43 TOTAL LOT 9,079 S.F. f'' I i 0 . 0 EXISTING HOUSE 2,027 S.F. - $$f j -. o° NOOK pQ wESTINGDVEWAY / •:? FRONT PORCH&WALK ' 611 SF 1 I EXISTING PADS 46 S.F. AD •a 2.a 5.a `: ,��, /DITION :' TOTAL IMPERVIOUS 3,402 S.F. � 8.4' $ (37.5%) p CD i PAVERS PATIO 429 S.F. ¢� I. 0 L�/ TOTAL WI?WITH PAVERS=3,831 S.F. rri -I(42%) I O . 1 I el I �fO FASEMEM / I g— bI.1' 3s'-o1 5'U.E 1E12 30.07 FOUND 1/7' 1 1f - 10S 94t .WIE IRON ROD ? IRON PIPE LB#7893 1 LOT 1 LOT 8 .: SURVEY NOTES „ILt CONCRETE DRIVE CROSSING THE PROPERTY LINE ON EASTERLY SIDE OF LOT. THERE ARE FENCES NEAR THE BOUNDARY OF THE PROPERTY AND CROSS INTO THE I PERMANENT 5'U.E.ON SOUTHERLY SIDE OF LOT,AND THE PROPERTY LINE ON NORTHERLY AND SOUTHERLY SIDE OF LOT. I CONTROL POINT .0 1 0 Q s 0 �_ Na SNB BURVEYORSCERTFICATE TARGET t I HEREBY CERTIFY THAT THS BOUNDARY SURVEY o IS A TRUE AND CORRECT REPRESENTATION Of A SURVEYING,LLC SURVEY PREPARED UNDER MY DIRECTION. *I NOT VALD WITHOUT AN AUTHENTICATED ELECTROHC LB#7893 •, STATE OF . SIGNATURE AND AUTHENTICATED ELECTRONIC SEM. °•''1• 0 R I CP. °RARAISED D°” SEN.API) """`� SERVING FLORIDA a u v•y 6250 N.MILITARY TRAIL,SUITE 102 WEST PALM BEACH,FL 33407 PHONE(561)840.4800 i 020 Seel, /Dm>e ,4 ,, FL 3 -Q33 BOUNDARY SURVEY AA IAT 3 LOT 6 �0 T SET 1JY' IRONLB 99 X0.1' ,p N89.10'22'E 94.87 1D [ems W 'I LA r6'4 lAA gill 140SF II !wli ®9 • I cn D TACH:I.., w $.0 eWm. -0'ommitii 1 V •A • g Poi ItPX g EXISTING �. - I 'z RESIDENCE - 0 I BUILDING 17A / I X LOT 2 alezo 4 .� icol i 922 0. I B1sF *i/ ._A3imo - tr�I, �I mI � 91 __c a LFUE I$_ .aa —-I\ POUND 8z, 1.1'— E 1 LOT 1 U3 17893 LOT 8 r SURVEYNOTES 7YRCRE7ETIRNECROSSINGTHEPROPERTYUNEONEASTF%YSDEOFLor. 1 i THERE ARE FENCES NEAR THE BOUNDARY OF THE PROPERTY AND CROSS INTO TIE . PERMANENT 5 U.E.ON SOUTHERLY SIDE OF LOT,MD THE PROPERTY LME ON NORTHERLY AND SOUTHERLY SIDE OFLOT. I CONTROL Ftl1YT No.M/6 SURVEYORS TE TARGET • HEEOY CERTIFY THAT 11.03 lOAPOORY SURVEY $A TRUE AM CaaECT R@REBETATOR OF A SURVEYING,■•LC 90VMEPREPAREDUNDER DEiMYOFEC11011 NOT T VA1D RTIIOUT NI AUTHERYATHI EECT KING. LB PMS t. rtATEaP SIGNATURENO NHHEIIICATEI FLEMI NG SEAL R„• °RA"N®MOWED ff" BNOB°"TM SERVING FLORIDA 6250 H ABUTNtYTRAI.SUITE 102 WEST PALM BEACHA 33107 PINE(501)6W4B00 IyKaED7 _ STATENEEPHOIE(500)2264507 KENNETH J OBBORNEp�p�(� STATENEE FACSIMILE(300)7414571 FROFBNIQW.SURVEOR N01YPM01111 111$ 1' 1FACSIMILEM®BRE:IliJhIgIhUYw4p,R1 CGC1521502 COURSE C O N T R A C T I N G Treat others how you would want to be treated! Respect the neighbors. Respect the work of other Trades. This property will be around for you to drive your grandchildren by and tell them you built this! Construction is a noble profession;take pride in what you are doing! "When we build, let us think that we build forever. Let it not be for present delight, nor for present use alone;let it be such work as our descendants will thank us for." -John Ruskin, 1849 • SAFETY FIRST!Think and focus on what you are doing.The safest way is not always the quickest or easiest way of doing work, but it is the only way if you want to go home in the same condition you arrived.Your family and friends need you. • All material and debris to be kept off the streets. Look for garbage in the streets and ensure worksite is clean each day. • Drugs and alcohol will not be tolerated on site before,during or after working hours. Violators will be terminated. • Smoking is prohibited on this property at all times. If you need to smoke you must be in your vehicle on the street. • Absolutely no activity before 7:00 a.m. or after 7:00 p.m. unless authorized by Course Contracting. This means no saws, radios or yelling. NO WORK ON SUNDAYS. • Jobsite cleanup is mandatory daily and the responsibility of each vendor and/or contractor. This includes disposing of all soda cans, cups and lunch trash. Let's maintain a clean and orderly jobsite that is broom swept before the next trade arrives. • All contractors are responsible for complying with OSHA regulations. Personal Protective Equipment (PPE) is required and is the responsibility of each vendor and/or contractor. • Close and lock all doors and windows before leaving. • Jobsite theft will be prosecuted. • Refer all owner or neighbor questions or comments to Course Contracting personnel.