Loading...
130 Jackson Rd ROW18-0046 JEA pole permit rSr RIGHT OF WAY PERMIT PERMIT NUMBER J CITY OF ATLANTIC BEACH ROW18-0046 J 800 SEMINOLE ROAD ISSUED: 12/21/2018 ATLANTIC BEACH, FL 32233 EXPIRES: 3/21/2019 MUST CALL INSPECTION • • 1 , ) 247-5814 BY , PM FOR ` INSPECTION. ALL • 'K MUST CONFORM TO THE CURRENT 6TH EDITION1 OF • ' ` BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: RIGHT OF WAY SINGLE OR TWO 130 JACKSON RD FAMILY RIGHT OF WAY install 35-ft. pole $0.00 TYPE OF • • GROUP: 1721410000 DONNERS S/D PT LOT 2 17- • ADDRESS: Jacksonville Electric 21 W. Church Street Jackonville FL 32202 Authority • STATE: TOWNSEND SHARON RENEE 960 HAGLER DR NEPTUNE BEACH FL 32266-3754 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF • . • Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. Issued Date: 12/21/2018 1 of 2 RIGHT OF WAY PERMIT PERMIT NUMBER CITY OF ATLANTIC BEACH ROW18-0046 v 800 SEMINOLE ROAD ISSUED: 12/21/2018 ATLANTIC BEACH. FL 32233 EXPIRES: 3/21/2019 2 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration,including sod,is required. 3 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL Notes: Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed,call 247-5878. 4 PUBLIC UTILITIES UTILITY MAP INFORMATIONAL Notes: See attached Utility Map. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT TOTAL: Issued Date: 12/21/2018 2 of 2 City of Atlantic BeachECEIVE APPLICATION NUMBER ys s� Building Department (To be assigned by the Building Department.) 800 Seminole Road DEC 19 2018 �- (��1 �'004 b s� Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5 tct t l-l T E-mail: building-dept@coab.us � :__. Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: �� j a u-Sov� 1c (, Department review required Yes No LL Building Applicant: Planning &Zoning _ Tree Administrator Project: k n u I,t 3 S - �A 01-0 < Public Works lic Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [Approved. []Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING r Reviewed b A Date: TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 s-="Jr,J, City of Atlantic Beach APPLICATION NUMBER J� n� Building Department 800 Seminole Road JECEilV (To be assigned by the Building Department.) , ' 1 Q Atlantic Beach, Florida 32233-5445 � ^� -V W 1 p —00�_l Phone (904)247-5826 - Fax(904)247-584 DEC 19 2018 i E-mail: building-dept@coab.us Date routed: l-t City web-site: http://www.coab.us i3K APPLICATION REVIEW AND TRACKING FORM Property Address: 3 GLC-� SC7�j �� Department review required Yes No Building Applicant: �- Planning &Zoning _ I Tree Administrator Project: t n. (� L� 3 S1 _ �, Public Works lic Utilities Public Safety Fire Services Review fee $ J`rw "Dept Signature' fi Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APP (CATION STATUS Reviewing Department First Review: JApproved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by:1Z I,"-- ate: TREE ADMIN. Second Review: A roved as revi d. ❑ pp ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 A ir ryRB" �.> how--M-- r � s p , #� ?k. yy � ION, 4 •� aha • P a � p p r M - RIGHT-OF-WAY/EASEMENT PERMIT APPLICATION "ALL INFORMATION City of Atlantic Beach HIGHLIGHTED IN GRAY IS V c 800 Seminole Road,Atlantic Beach,FL 32233 REQUIRED: ' PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES q Job Address � �(� Permit Number Contractor Information Company_ �1�17 Qualifying Agent Address_ t (.t)1651L City 1 AX State_Zip-3 Phone Email State Certification/Registration# Architect Phone Email Engineer. S t` Phone—66S- 77 Email 9,'0,,0t2 Workers Compensation Insurer ✓ OR Exempt❑Expiration Date • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities,both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement,maintenance,safe and efficient operation,alteration or relocation of all,or any portion of said street or easement as determined by the Public Works Director,any or all said poles, wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said street or easement or reset or relocated hereon as required by the Public Works Director and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of (Project Superintendent) with (Company Name) Phone &(Ps-- .3 • All materials and equipment shall be subject to inspection by the Public Works Director. • All city property shall be restored to its original condition as far as practical,in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • The permittee shall commence actual construction in good faith within days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Public Works Director to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right, title and interest in the land to be entered upon and used by the holder,and the holder will,at all times,assume all risk of and indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. • The I' or c or shall be notified 24 hours prior to starting work and again immediately upon compI do . Date_ Permittee(signed in presence of otary Public) STATE OF FLORIDA,COUNTY OF DUVAL The foregoing instrument was acknowledged this day of. 20_ by who personally appeared before me and (printed name of Permittee) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. [ ]Personally Known Signature of Notary Public,State of Florida [ ]Produced Identification(Type) H:\Applications&Forms\Word Documents\201801001 Right-of-Wav Ea--, ,rermit Application.docx Revision Date:10/1/18 ENGINEERING DESIGN ORACLE PERMIT MAXIMO DATE REL PROJECT#:36663 N.O.: 8005212 WO#: 30379638 CONST 12/19118 CIR. TREE TRIMMING SUB-STA: NEPTUNE BEACH N.O.: 561 REQ'D:NO CELL ENGINEER: Robert Simpson N.O,: NIA ZIP CODE: N/A CUSTOMER/ SVC PHONE LOCATION: 114 JACKSON RD./3514W POLE INSTALL 561 CENTER: SSSC N.O.:665.7793 STA 1, P# 128 JACKSON RD./ 1/ INSTALL 35/4W RUN 4/OP TO STA 2. I STA 2, P# 141 JACKSON RD./ 9 REPLACE 50KVA WITH 75KVA. r ! o Mtn 1-4 I kz MM 0000 r 0000 I V-i -{ I STA 2 r 127 0• I ,._, --i MAYPORT RD. ONO I 000 0000 Ln 110 - - - - - -- _ - �_ -p-p 210P I 4/OP/ I I I I 2T 1/0 1/ 1/0 /OT 1/OT 110 120 130 140 STA 1 19 121 1 70 117 123 91 1/OT 1/OT T E-77 7" CUE Reports Estimate Number:36663 114 JACKSON RD./POLE INSTALL Estimate Type:SR Contract:089-16-HM OH FY19 Estimate Version: By: SIMPRB MWO#/Task:30379638 Required Date: Oracle Project#:8005212 Estimated On: 12/19/2018 Cost Estimate Materials JEA Contractor 1.New Material Cost(w/sales tax) $789.41 $789.41 2.Transformer Cost(w/sales tax) $1,966.37 $1,966.37 3.Returned Material Salvage Value $0.00 $0.00 Labor 4.Crew Time $588.58 $1,023.38 5.Extraordinary Costs $0.00 $0.00 JEA Overhead 6.Fringe Benefits(54.56%of lines 4&7) $410.88 $152.44 7.Engineering Costs(Variable%of line 4) $164.51 $279.40 8.Project Equipment Costs(40%of total equipment costs) $345.01 $0.00 9.Material Handling(8.30%of lines 1 &2) $228.73 $228.73 10.Inspection(6.84%of line 4) $0.00 $70.00 11.Total Cost of Project $4,493.49 $4,509.73 12.Work Order Estimate(Line 11 minus line 8,9,&10) $3,919.75 $4,281.00 13.Billable Equipment Depreciation(60%of total equipment costs) $517.51 $0.00 14.Billing Estimate(Including Transformer Cost)(Lines 11 +13+(58.71%of 4&7)) $5,453.14 $4,673.77 15.Billing Estimate(W/O Transformer Cost)(Lines 11 +13+(58.71%of 4&7)-Line 2) $3,486.77 $2,707.39 Time Estimate Crew Hours Total Manhours 4.72 18.88 ---------------------------------------------------------------------------------------------------------------------------------- . A. CUE Reports Estimate Number:36663 114 JACKSON RD./POLE INSTALL Estimate Type:SR Contract:089-16-HM OH FY19 Estimate Version: By: SIMPRB MWO#/Task:30379638 Required Date: Oracle Project#:8005212 Estimated On: 12/19/2018 Material Summary Item Quantity Item Number Item Description 1 ANCSS002 ANCHOR, SCREW, SINGLE-HELIX, GALVANIZED 10"X 8'X 1-1/4", SHIP ON OPEN FLATBED ONLY! 1 ARRL1003 ARRESTER, LIGHTNING, 18 KV, DISTRIBUTION CLASS AND RISER POLE (MOV)WITHOUT MOUNTING BRACKET, 15.2/26.4Y NOMINAL VOLTAGE 1 BKTAC009 BRACKET, ARRESTER AND CUTOUT, FIBERGLASS WITH RAYCHEM MATERIAL OVER ROD TYPE: SINGLE PHASE 2 BOLMS035 BOLT, MACHINE, 3/4"X 12", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 3 BOLMS036 BOLT, MACHINE, 3/4"X 14", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 12 BOLTE001 BOLT, TERMINAL KIT, (KIT INCLUDES ) 1-EACH 1/2"DIA.X 2"S/S BOLT FULL THREAD, 2-EACH S/S FLAT WASHERS, 1-EACH S/S BELLEVILLE 1-SILICON BRONZE NUT(SHIPPED IN BAGS OF 10-EACH ASSEMBLED ) "(SEE SPECIFICATION)" 65 CA10SO03 CABLE,4/0-19(PAP), OVERHEAD SERVICE DROP, 600 VOLT MULTIPLEX CABLE"VICKSBURG" PRE-ASSEMBLED PARALLEL 1000 FOOT REELS 1 CLAGRO01 CLAMP, GROUND ROD, 5/8"-4SOL "HAMMERLOCK" 4 CLASR002 CLAMP, STRAIN RELIEF WEDGE, ALUMINUM, 1/0 TRI-4/0 PAP 2 CLASS006 CLAMP, STRAIGHT STRAIN,ALUMINUM, 10000#3/0-556 ALUM (STD PKG 15 EA) .1 CLATGO01 CLAMP,TRANSFORMER TANK GROUND, "BRONZE"6 SOL-1 STR. . 3 CNNCP002 CONNECTOR,#2, 6-2 MAIN, 2-1/0 TAP,ALUMINUM COMPRESSION, PARALLEL TAP, 16 CNNCP007 CONNECTOR,#7, 3/0-4/0 MAIN, 3/0-4/0 TAP COMPRESSION, PARALLEL TAP,ALUMINUM, 3 CNNTS006 CONNECTOR, TRANSFORMER SECONDARY SET SCREW TYPE W/INHIBITOR, 4-HOLE NEMA RANGE: 10-500, 3-PORTS. 4 CNNVG003 CONNECTOR, 6-2 SOL/10-2 SOL,VISE GRIP PARALLEL, BRONZE 36 COBC0028 CONDUCTOR, #4 SOLID, SOFT DRAWN, BARE COPPER, 200', 25#,ON PLASTIC REEL,4"X 11.5"W/2" HOLE 70 COBCW014 CONDUCTOR, #4, TYPE 40 DSA, COPPERWELD&COPPERWELD- COPPER .204" DIAMETER 1480#BREAKING STRENGTH (50#COIL- 427' ) 18 COVIC002 COVER, "D"DIE, INSULATING,2-1/2" 1 CUTOT006 CUTOUT, CONTAMINATED ENVIRONMENT, 26" LEAKAGE DISTANCE TO GROUND, 100A, 27 KV, 170 KV BIL (54 EA PER PALLET) 1 FUSOH026 FUSE, OVERHEAD DISTRIBUTION,5.2 AMP, TRANSFORMER. 1 GUAGWO01 GUARD, GROUND WIRE, 1/2"X 1/2"X 96", GRAY PLASTIC 1 GUAGWO02 GUARD, "YELLOW", GUY WIRE, 1/4"TO 1/2"8', POLYETHYLENE, USED ON ALL 3/8"AND 7/16" GUY STRANDS (DISTRIBUTION) 1 GUYAT008 GUY HOOK, COMBINATION, MALLEABLE OR DUCTILE IRON, HOT DIP GALV. 13/16" MOUNTING HOLE,20,000 LB MIN. ULT.STRENGTH. FOR WOOD OR CONCRETE POLES CUE Reports Estimate Number:36663 114 JACKSON RDJ POLE INSTALL Estimate Type:SR Contract:089-16-HM OH FY19 Estimate Version: By: SIMPRB MWO#/Task:30379638 Required Date: Oracle Project#:8005212 Estimated On: 12/19/2018 2 GUYGRO01 GRIP, GUY, 3/8", 26", GALVANIZED 50 GUYST005 STRAND, GUY, 3/8" DIA, 7 PER STRAND, GALVANIZED STEEL, CLASS "B" GALV. OR BEZINOL IS ACCEPTABLE (500'COIL) 1 INSG6002 INSULATOR, STRAIN, GUY BREAKER, 21,000#RATED, 60" ROD LENGTH, FIBERGLASS FOR USE ON JEA'S DISTRIBUTION SYSTEM ONLY 2 INSS0002 INSULATOR, SUSPENSION,4", CLASS 52-9 NEMA STRENGTH 10000#, GALV. FITTINGS 2 NUTSL003 NUT, LOCK, SQUARE, 5/8"HOLE SIZE, HOT DIPPED GALVANIZED 2 NUTSL004 NUT, LOCK, SQUARE, 3/4"BOLT SIZE, HOT DIPPED GALVANIZED 1 POLW0003 POLE, WOOD, 35'CLASS 4 (T/L=44), WEIGHT=1,026 LBS 1 RODGRO03 ROD, GROUND, THREADLESS, 5/8"X 8', SHIP ON OPEN FLATBED ONLY! 2 SLEFT006 SLEEVE, 4/0 7-STR AAAC, FULL-TENSION ALUMINUM, COMPRESSION TYPE 1 TAGH0007 ALUMINUM VERTICAL TAG HOLDER FOR ADHESIVE BACK CHARACTERS((NOT FOR"SLIDE IN"CHARACTERS)). 19.5"HIGH X 2" WIDE WITH 3-1/8"NAIL HOLES @ THE TOP AND THE BOTTOM. (PKG. OF 50 EACH) 1 TRAC0003 TRANSFORMER, 75 KVA, 14760/25565Y VOLT PRIMARY, 120/240 VOLT SECONDARY, SINGLE PHASE, CONTAMINATED ENVIRONMENT 2 WASRD004 WASHER, ROUND, 5/8"BOLT SIZE X 13/4"DIAMETER, GALVANIZED, 650 EA P/BOX) 5 WASRD005 WASHER, ROUND, 3/4"BOLT SIZE X 2"DIAMETER, GALVANIZED,*** 500 EACH PER BOX*** 3 WASSF003 WASHER, SQUARE FLAT, 3"SQ X 1/4", 5/8"X 3/4" BOLT SIZE, GALVANIZED 1 WASSP002 WASHER, SPRING, 3/4"BOLT SIZE, DOUBLE COIL HELICAL TYPE, GALVANIZED (EXTRA HEAVY DUTY) CUE Reports Estimate Number:36663 114 JACKSON'./POLE INSTALL Estimate Type:SR Contract:089-16-HM OH FY19 Estimate Version: By: SIMPRB MWO#/Task:30379638 Required Date: Oracle Project M 8005212 Estimated On: 12/19/2018 CU Detail JACKSONStation: 01 128 -■ Build Transfer Remain in Place Remove C.4/OP 65 DEEPER 1 G3W*2 1 GY3*5 1 P.35/4W 1 S4*4/0 2 Build , . "N"s s - Transfer Remain In Place Remove BANKCOMP10 1 DGAC*75 1 HOUSECON 4 RUBUP 2 S20ES*4/0-4/0 4 S9*4/0 2 RUBDOWN 2 CUE Reports Estimate Number:36663 114 JACKSON RD./POLE INSTALL Estimate Type:SR Contract.089-16-HM OH FY19 Estimate Version: By: SIMPRB MWO#/Task:30379638 Required Date: Oracle Project#:8005212 Estimated On: 12/19/2018 CU Summary CU Name Quantity Description BANKCOMP10 1 SINGLE PHASE COMPLETE BANK (LARGEST TRANSFORMER 75KVA OR UNDER) C.4/OP 65 4/0 AAC PAP W/4/0 AAAC NEUTRAL DEEPER 1 SET POLE DEEPER, PER FT. DGAC*75 1 TRANS; CI, 26AKV 120/240 75KVA G3W*2 1 WOOD POLE- NON-EQUIPMENT GROUND GY3*5 1 GY3*5 3/8" DOWNGUY W/8 FT SCREW ANCHOR HOUSECON 4 S21 REMOVAL P.35/4W 1 35 FT. CLASS 4 WOOD POLE RUBUP 2 LINE RUBBER INSTALLATION, PER SECT. S20ES*4/0-4/0 4 SECONDARY CONNECTION AT POLE S4*4/0 2 SECONDARY DEADEND S9*4/0 2 SECONDARY SPLICE CuName Quantity Description RUBDOWN 2 LINE RUBBER REMOVAL, PER SECT.