351 1ST ST - EXTERIOR REPAIR DRAWINGSC44') At, = o`' C.. epo �.� {•9ivrY ���� i+ EXISTING HEATED. 1,444 SQ.FT. JOB DESCRIPTION: REMOVE CEILING IN LIVING ROOM & KITCHEN BEAM REATACH EXISTING RA ERS INSTALL NEW RIDGE ENLARGE ENTRANCE TO FLORIDA ROOM ADD NEW OVER FLORIDA ROOM & HEADER PORCH STRUCTURE 2,006 SQ -FT CONSTRUCT NEW ENTRY IINREXISTING ROOF NE ON NEW OOVER OF OVER INSTALL TO O LIVING & KITCHEN. WALKS & DRIVES 834 SQ- r � POOL DECK 987 SQ -FT - ADDITIONAL PORCH 84 SQ— T .y+�� r,r '� � y�9' 1" FT-TOTAL COVERED 3,968SQ.FT. 9,750 SQ - LOT AREA Lot 18 &THE FT -POST CONSTRUCTION 40% PLAN LOT COVERAGE Ast 6' of lot 20 A 1` JOB DESCRIPTION: REMOVE CEILING IN LIVING ROOM & KITCHEN BEAM REATACH EXISTING RA ERS INSTALL NEW RIDGE ENLARGE ENTRANCE TO FLORIDA ROOM ADD NEW OVER FLORIDA ROOM & HEADER PORCH REPLACE CEILING & ROOF INSTALL NEW HEADER AND POST AT NORTH END 0 STEPS AND ADD RAISED F PORCH ORCH CONSTRUCT NEW ENTRY IINREXISTING ROOF NE ON NEW OOVER OF OVER INSTALL TO O LIVING & KITCHEN. IN STALL TWO SKOYLIGHTS REPLACE EXISTING INSULATION WITH 5 1/2" ICYE E SPRAY INSULATION. T .y+�� r,r '� � y�9' 1" : 3 Lot 18 &THE WEST 19.2' OF PLAN LOT 16 & E Ast 6' of lot 20 A SITE 1 scale i"= 30'-0" JOB DESCRIPTION: REMOVE CEILING IN LIVING ROOM & KITCHEN BEAM REATACH EXISTING RA ERS INSTALL NEW RIDGE ENLARGE ENTRANCE TO FLORIDA ROOM ADD NEW OVER FLORIDA ROOM & HEADER PORCH REPLACE CEILING & ROOF INSTALL NEW HEADER AND POST AT NORTH END 0 STEPS AND ADD RAISED F PORCH ORCH CONSTRUCT NEW ENTRY IINREXISTING ROOF NE ON NEW OOVER OF OVER INSTALL TO O LIVING & KITCHEN. IN STALL TWO SKOYLIGHTS REPLACE EXISTING INSULATION WITH 5 1/2" ICYE E SPRAY INSULATION. New coverage less then 400 sq. ft TABLE OF C( SHEET 1 SHEET 2 SHEET 3 SITE / PLAN DESIGN INFORMATIC FOUNDATION/ FOUNDATION DE1 FLOOR PLAN / WALL SECTIONS SHEET 4 SHEET 5 SHEET 6 BUILDING ELEVATIONS GENERAL NOTES STRUCTRUALO ES & SPECIFIC N NOTES: CONTRACTOR TO VERIFY FIELD CONDITIONS. CONTRACTOR TO NOTIFY DESIGNER CONFLICTS BETW CONTRACTOR RESPONCIABLE FOR MEANS & METHOD` BUILDING CODE RESIDED WIND SPEED 1301 WIND EXPOSURE EXPO TYPE OF CONSTRUCTION T OCCUPANCY CLASS REMODEL CATAGORY ALTER) ISK LEVEL II NATIONAL FIRE PROTECTION CODE 2017 LOT COVERAGE NET Ct PLAN DATE i Revisions RMI BLOCKING 48" O.C. AT GABLE ENDS 2'x 1'8" x12" NAIL 5/8" V-C�mt 3 #5 EW 2' PLYWOOOD ed steel N 2'x2'xi2" 4 SIDES 6" O.C. ♦— in existing footing 3#5 EW Existing stair CONNECT (2) 2X12 HEADER TO EXISTING TIE BEAM WITH SIMPSON MSTAM 36. W/ (13) 10d WOOD BEAM (8) 1/4 X 1 3/4 "TITEN 2" SCREWS IN TO CONCRETE BEAM EACH SIDE OF BEAM F— (2) 11 1/4 " LVL T:y0 1 .c2 p 1111) q�Foundation Plan 1 / Scale 1/8 " Existing Floor Beam Tie Down 12" Sono Tube Strap 3,000 PSI Concrete META 12 (FL11473) 5/8" Bar 1 Foundation Section 2 3/4" scale 3 5/8" Bar E.W. Entry #5 Bar 12" o.c. j2' I '" g Roof Framin Plan 1 5/8" Bar Each Step B A 3 ( ) Y Existing Wood Floor 5k2 Existing Foundation scale 1/8" z7T � I 2'x2'x 10" Footing _ Q Beam 3 5/8 EW5/8" New NEW VELUX CURB MOUNT 22X46 1 12" Dia. Sonotube U-) 4 SKYLIGHTS z 2 1 #5 Vertical w ATTACH H2.5A EACH EXISTING 4 4 z w 2X6 TOO FITFIT NEW C V / RAFTER TO 2X12 BEAM N rl w Existing Foundation Ili New 4'-4" x 2' x 10" concrete footing 3 #5 bars N New LVL Roof Beam 1 q�Foundation Plan 1 / Scale 1/8 " Existing Floor Beam Tie Down 12" Sono Tube Strap 3,000 PSI Concrete META 12 (FL11473) 5/8" Bar 1 Foundation Section 2 3/4" scale 3 5/8" Bar E.W. Entry #5 Bar 12" o.c. j2' I '" g Roof Framin Plan 1 5/8" Bar Each Step O� 5k2 scale 1/8" 2'x2'x 10" Footing _ Q 3 5/8 EW5/8" BAR H 2.5 A 4" concrete slab EACH RAFTER U-) OF BEAM TO z CUTG //TO NEW BEAM NEW HEADER w 2X6 TOO FITFIT NEW C V / BEAM . (1) 5/8" Bar 4" Slab 0=11117- 11" 0 8X8x16 6,. a e Ilk STAIR SECTION 1/2" scale g„ Compacted Fill 5/8" Bar 8x16" CMU Fill Cells 4'-0" o.c. 6 10x 16" Concrete 12x10 Footing Footing �a EIR (3) LVL BEAM SPRAY 5/1/2" FOAM (ICYENE)INSULATION ALL CEILINGS NEW LVL'S NEW 2X10 HEADER BEAM 1 MSTA 36 HEADER TO JACKS 3 N16, PORCH EDGE (3) 5/8" Bar 4 NEW RIDGE BEAM 4 NEW RIDGE BEAM TIE DOWN 2 3/4" scale N-11 3/4" scale 2 3/4" scale Roof o j Q o Zj a LU 0 <OU0 LnJ a -j a Ln W LL Z Q N � Ce Lu 0, n 00'UI, 0 MOUZO rn ca0-q 12/10/18 A 2 Y U a } z O� �w w _ Q F+ HTS20 EACH SIDE O U-) OF BEAM TO z NEW HEADER w C V / rl w OM Ili J 12/10/18 A 2 Y U a } TWIST STRAP ONE EACH SIDE OF BEAM HTS30 24 10d HTT4 NEW FOUNDATION PIER 0 --- FLORIDA ROOM PORCH BEDROOMS INSTALL HTT4 BATH TO CONNECT JACKS TO EXISTING LIVING ROOM FLOOR BEAM 2 3 KITCHEN BATH BEDROOMS Twist Strap HTS 30 3 11-1/4" LVL FLAT STRAP 3 #2 YP 2x4 I 3 #2 YP 2X4 I/ MSTA 36 NEW 2X10#2 YP HEADER TWIST STRAPS HTS 30 (3) 11-1/4" LVL H MSTA 36 NEW 2 #2 YP 2X4 3 #2 YP 2x4 JACKS EACH SIDE .i Cv HTT4 HTT4 1 (1) EACH SIDE II EXISTING FLOOR FRAMING q Floor Plan aEXISTING CMU FOUNDATION META12 k,A3 1/8" Scale NEW LVL BEAM 1 B 3 #2 YP BLOCKS uilding Section �113uilding Section NEW 32 YP 2X10 HEADER 3 *scale 1/2" A3 *scale 1/2" 2 2X4 i;#2 SPF JACKS EXISTING 2X6 CURB 2X6 RAFTER 1HTT4 EXISTING FLOOR FRAMING STRAP ATTACHED TO EXISTING FLOOR GIRDER META12 4" EMBEDMENT MIN. r3'*#"NWall Framing Elevation IV, � 3 * scale 1/4" 12" 12" SURROUNDS OPENING TOE NAIL 12d @ 16" O.C. New Skylight Framing 4 In Existin Roof (PLAN) J3* scale 1/411 INSTALL ACCORDING TO MANUFACTURES SPECIFICATIONS EXISTING 2X6 RAFTER 0 J D QpULn Lu -j w O z Q N E-�4mo+ aLLdU^ 0 0 0Z z �L�gM mLu MSTA r 0 �-- �W Q W 0 U) W ,--I W Lli 0 X NEW SKYLIGHT N FRAMING N 12/10/18 CUT EXISTING q RAFTER 3 OFFICE COPY L E EXISTING ROOF A FRONT ELEVATION A4)* scale 1/8" E NEW New Steps NEW LVL BEAM NEW POST C N O'RTH ELEVATION 44 *scat 1/8" NEW CONCRETE PORCH ROOF NEW ROOF B EAST ELEVATION ��4* scale 1/8" 1 m z OF- �W QW >F- O Lf) W U) w� >Lr) OM rD-'4' WEST ELEVATION OFFICE COPD 12'10/18 ��4* scale 1/8" A 4 EXISTING ROOF NEW LVL BEAM NEW POST EXISING CMU WALL B EAST ELEVATION ��4* scale 1/8" 1 m z OF- �W QW >F- O Lf) W U) w� >Lr) OM rD-'4' WEST ELEVATION OFFICE COPD 12'10/18 ��4* scale 1/8" A 4 GENERAL NOTES: 1. THE CONTRACTOR SHALL VERIFY ALL CONDITIO IS AND DIMENSIONS AT THE JOB SITE PRIOR TO COMMENCING WORK. THE CONTRACTOR SHALL REPORT ALL DISCREPANCIES BETWEEN THE DRAWINGS AND EXISTING CONDITIONS TO HE DESIGNER & OWNER PRIOR TO COMMENCING WORK. 2. THE CONTRACTOR SHALL SUPPLY, LOCATE AND 13UILD INTO THE WORK ALL INSERTS, ANCHORS, ANGLES, PLATESOPENINGS, SLEEVES, HANGERS, SLAB DEPRESSIONS AND PITCHES AS MAY BE REQUIRED TO ATTACH AND ACCOMMODATE OTHER WORK. 3. ALL DETAILS AND SECTIONS SHOWN ON THE DR WINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONST WED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE IN THE WORK EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. 4. SUBSURFACE SOIL CONDITION INFORMATION IS'INOT AVAILABLE. FOUNDATIONS ARE DESIGNED FOR A SOIL BEARING CAPACITY OF 2,000 PSF. THE CONTRACTOR SHALL REPORT ANY DIFFERING CONDITIONS TO THE DESIGNER & OWNER PRIG � TO COMMENCING WORK. 5. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATION AND ARCHITECTURAL, MECF ANICAL, ELECTRICAL, PLUMBING, AND SITE DRAWINGS, CONSULT THESE DRAWINGS FOR SLEEVES, DEPRESSIONS AND OT DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS. 6. ALL BOLTS, NUTS, WASHERS, STRAPS AND FASTENERS INCLUDING NAILS, SHALL BE HOT DIP GALVANIZED OR STAINLESS STEEL. CONTINUOUS ANCHORAGE SHALL BE PROVIDED BETWEEN ALL TRUSSES, WALL SECTIONS, BEAMS, POSTS AND FOOTINGS WITH USE OF STRAPS AND CONNECTORS AS SPECIFIED HEREIN. 7. ALL SPECIFIED FASTENERS MAYBE SUBSTITUTEI] WITH DEVICE OF EQUAL OR GREATER COMPACITY. 8. THE INSTALLATION OF THE FASTENERS SHALL B8 IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. WIND BRACING (1ST AND 2ND FLOORS) 4'-0" X '4" x 1/2" EXTERIOR GRADE PLYWOOD SIDING. NAIL 6" O.0 FIELD AND EDGE. Install Z Flashing ABOVE WINDOW TRIM LAP HOUSEWRAP OVER FIN AT WINDOW HEAD ONLY THEN SEAL WITH PEEL STICK TAPE WINDOW FLASHING 1 NTS scale A6 ye't'�x�w:�o� +�"t�s`t�fir5ricr Seal All Fins with 6" Peel & Stick (FIN TO HOUSEWRAP) LAP ALL JOINTS FROM ie Vinyl Window. AND SEAL WIDOW JUFACTURES RECOMADATIONS Stick Sill Flashing VER HOUSE WRAP RMINATIONS) NOT USED 2X12 SYP #2 LEDGER FASTEN TO ROOF WITH 3/8"SMPSON SDS SCREWS. TWO SCREWS INTO EACH EXISTING RAFTER 1 SIMSON SDWC SCREW EACH RAFTER TO LEDGER ROOF OVER FRAMING CONNECTION DETAIL D A5 ME OFFICE COP Q 0� -�QWO QpU-j w-zaN tu-C'Lu 0., �u- CYU oLn0 a, rn CO z 0� � W Q W 0 u') W Lu '-� 0� i M 1 12/10/18 1 0 CONCRETE: 1. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS, UNLESS NOTED OTHERWISE. PLACEMENT SHALL BE IN ACCORDANCE WITH ACI 318. 1. ALL WOOD FRAMING SHALL BE FABRICATED AND INSTALLED PER AITC AND TPI AND NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION. IN ACCORDANCE WITH TABLE 2304.6.1 & 2304.10.1 (UNLESS OTHERWI",E NOTED) 2. ALL STRUCTURAL WOOD MEMBERS SHALL BE SOUTHERN YELLOW PINE. UNLESS NOTED OTHERWISE. 2. ALL CONCRETE SLABS ON GRADE SHALL BE THE THICKNESS INDICATED ON THE DRAWINGS, OVER 3. MINIMUM 6 MIL POLYETHYLENE VAPOR BARRIERS. SUCH SLABS SHALL BE REINFORCED WITH 6" X 6" #10/10 WELDED WIRE FABRIC LAPPED 8" AT EDGES AND ENDS. 3. FILL UNDER CONCRETE SLABS SHALL BE CLEAN SAND OR ROCK AND FREE OF DEBRIS AND OTHER DELETERIOUS MATERIAL. FILL SHALL BE COMPACTED TO A DENSITY OF AT LEAST 95% OF STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM D1557). UNLESS NOTED OTHERWISE THE FOLLOWING MINIMUM GRADES SHALL BE USED: A. STRUCTURAL LIGHT FRAMING SIZE 2" TO 4" THICK X 2" TO 4" WIDE; NO. 2 NON -DENSE OR BETTER. B. STUDS SIZE 2" TO 4" THICK X 2" TO 6" WIDE; NO. 2 DENSE OR BETTER .C. STRUCTURAL JOIST AND PLANKS SIZE 2" TO 4" THICK X 5" TO 8" WIDE; NO. 2 OR BETTER; 9" TO 12" WIDE; NO. 1 OR BETTER. D. LIGHT FRAMING SIZE 2" TO 4" THICK X 3" TO 4" WIDE; NO. 2 NON - DENSE OR BETTER. E. STUD GRADE S.P.F. CAN BE USED IN LIEU OF SOUTHERN YELLOW PINE FOR STUDS ONLY 4. PLYWOOD SHEETING SHALL BE APA STRUCTURAL 1., GROUP 1 SIZE AND SPAN 4. FOOTINGS SHALL BEAR UPON UNDISTURBED TREATED RATING AS SHOWN ON THE DRAWINGS. NAIL WITH 8D NAILS (COMMON OR SOIL OR UPON SOIL COMPACTED TO AT LEAST 95% OF GUN) AT 6" O.C. ALONG PANEL EDGE AND 6" O.C. AT INTERMEDIATE STANDARD PROCTOR MAXIMUM DRY DENSITY (ASTM SUPPORTS. D1557: FOR A DEPTH OF AT LEAST THREE (3') FEET 5. ALL WOOD MEMBERS EXPOSED TO WEATHER OR IN CONTACT WITH BELOW THE BOTTOM OF THE FOOTING, MASONRY, CONCRETE OR SOIL SHALL BE PRESSURE TREATED. 5. WHERE SHOWN, CORES OF BLOCK MASONRY SHALL 6. CONTRACTOR SHALL PROVIDE ALL FASTENING DEVICES AS SHOWN ON THE BE FILLED WITH GROUT OR PEA GRAVEL CONCRETE DRAWINGS AND AS NECESSARY AND SUITED FOR EACH APPLICATION. WITH MINIMUM COMPRESSIVE STRENGTH OF 3000 FASTENINGS SUBJECT TO MOISTURE SHALL BE HOTDIP GALVANIZED TO ASTM PSI AT 28 DAYS AND REINFORCING STEEL AS A-153-80, OR STAINLESS STEEL. INDICATED ON THE DRAWINGS, 6. REINFORCING STEEL SHALL BE ASTM A-615 GRADE 60 DEFORMED NEW BILLET STEEL CONFORMING TO ACI 301, ACI 315, ACI 318 AND CRSI MANUAL OF STANDARD PRACTICE LATEST EDITIONS. MINIMUM LAP SPLICES SHALL BE 48 BAR DIAMETER. 7. ALL CONTINUOUS VERTICAL AND HORIZONTAL REINFORCING STEEL IN FOOTING, BEAMS AND COLUMNS SHALL BE SPLICED A MINIMUM OF 48 BAR DIAMETERS OR 24", WHICHEVER IS GREATER. 8. CONCRETE COVER OF REINFORCING STEEL SHALL BE AS FOLLOWS: A. FOOTINGS: 3" BOTTOMS AND SIDES, 2" TOP. B. BEAMS 11 /2" BOTTOM, SIDES AND TOP. C. COLUMNS: 11/2". D. SLABS ON GRADE: 2" BOTTOM, 1" TOP. E. OTHERS PER ACI 318. 9. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A- 185, FREE FROM OIL, SCALE AND RUST AND PLACED IN ACCORDANCE WITH THE TYPICAL PLACING DETAILS, OF ACI STANDARDS AND SPECIFICATIONS. MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. 7. ALL METAL CONNECTIONS AND FABRICATIONS SHALL COMPLY WITH AISC SPECIFICATIONS. MANUFACTURED BY SIMPSON STRONG TIE. 8. SOLID BLOCK ALL JOISTS AND RAFTERS AT POINTS OF SUPPORT. 9. PREFABRICATED STRUCTURAL TRUSSES SHALL COMPLY WITH NFPA NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION, TPI DESIGN SPECIFICATIONS FOR METAL PLATE -CONNECTED WOOD TRUSSES AND AITC 100. 10. ALL TRUSSES SHALL BE DESIGNED AND CERTIFIED BY THE TRUSS MANUFACTURER'S STATE OF FLORIDA REGISTERED ENGINEER. 11. CONTRACTOR SHALL CORRELATE WITH TRUSS MANUFACTURER TO ENSURE THAT ADEQUATE BEARING IS PROVIDED AT END REACTIONS OF ALL GIRDER TRUSSES. 12, TRUSS MANUFACTURER SHALL SUBMIT SHOP DRAWINGS TO THE CONTRACTOR AND DESIGNER FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF DIMENSIONS, MATERIALS AND CONDITIONS. 13. BRACE TRUSSES DURING ERECTION AND AFTER PERMANENT INSTALLATION TO COMPLY WITH TPI BWT-76. 14. MICROLLAMS (OR EQUAL PARALAMS, LVL'S, ETC) SHALL BE USED WHERE SPECIFIED ON ENGINEERED PLANS AND INSTALLED IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. ANY EDGES OR ENDS EXPOSED TO THE WEATHER SHALL BE PROTECTED BY THE INSTALLATION OF 36 GA., MIN., GALVANIZED STEEL FLASHING. DESIGN LOADS: THE STRUCTURAL SYSTEM HAS BEEN DESIGNED IN ACCORDANCE WITH THE REQUIREMENTS OF THE 6th edition 2017 FLORIDA BUILDING CODE. THE FOLLOWING WIND LOAD REQUIREMENTS, IN ACCORDANCE WITH 6th edition 2017 FLORIDA BUILDING CODE - BUILDING, CHAPTER 16, STRUCTURAL DESIGN SECTION 1609 AND ASCE 7-10, WERE USED IN THE DESIGN OF THE STRUCTURE: THE FOLLOWING SUPERIMPOSED LOADINGS HAVE BEEN UTILIZED: ROOF: LIVE LOAD- 20 PS DEAD LOAD- 10 PSF LIVING AREAS: LIVE LOAD -40 PSF DEAD LOAD -10 PSF WIND: SECTION 1609 OF THE 6th edition 2017 FLORIDA BUILDING CODE FOR THE 130 MPH WIND ZONE. CHAPTER 3 ( USE & OCCUPANCY) GROUP OCCUPANCY: "R" CHAPTER 5 ( BUILDING HEIGHTS & AREAS) HEIGHT < 20 FT CHAPTER 6 ( TYPE OF CONSTRUCTION) TYPE OF CONSTRUCTION: (VB) FULLY ENCLOSED IMP = 1 EXP=B RISK CAT #2 STRUCTURAL CALCULATIONS USING GRAVITY LOADS HAVE BEEN PERFORMED IN THE DESIGN OF THIS STRUCTURE. O_j aouo °gkD uLn W LL Z ¢ N t � jt00, aOCYU_n wU zo rn m0_Q z 0 �- LU Q w 0� Vim. j LL � uj 0 OFFICE COPY 12/10/18 Q m