Loading...
461 ATLANTIC BLVD ROOF19-0003 ROOF PERMIT ROOF NON SHINGLE PERMIT PERMIT NUMBER CITY OF ATLANTIC BEACH ROOF19-0003 V 800 SEMINOLE ROAD ISSUED: 1/11/2019 "LJ7319` ATLANTIC BEACH. FL 32233 EXPIRES: 7/10/2019 MUST CALL INSPECTION • • • 1 + 247-5814 BY 4 PM FOR + INSPECTION. ALL • ' K MUST CONFORM TO THE CURRENT 6TH EDITION1 OF • ' + BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 461 ATLANTIC BLVD ROOF NON SHINGLE PVC MEMBRANE ROOF $31750.00 TYPE OF BUILDING • • GROUP: 1706910010 SALTAIR SEC 03 COMPANY: ADDRESS: METRO PROPERTY SERVICES INC 3530 St Augustine RD JACKSONVILLE FL 32207 • ADDRESS: ATLANTIC BEACH YARD 1238 BEACH AVE ATLANTIC BEACH FL 32233 REAL ESTATE LLC WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 4SS-0000-322-1000 0 $210.00 BUILDING PLAN CHECK 4SS-0000-322-1001 0 $105.00 STATE DBPR SURCHARGE 4S5-0000-208-0700 0 $4.73 STATE DCA SURCHARGE 4SS-0000-208-0600 0 $3.15 TOTAL: $322.88 Issued Date: 1/11/2019 1 of 2 Building Permit Application Updated 10/9/18 City of Atlantic Beach Building Department "ALL INFORMATION J 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY Phone: (904) 24�7-5826 Email: Building-DeptCa)coab.us IS REQUIRED. (2aoF�C1 _ c)(5c)(53-5(,C,T � Job Address: 4(0( Ca_A �d C l-�q L Permit Number: CT MM Legal Description 0 L L-jV-ee- 455 . h4( RE# I"7 O(OCI I 00]0 Valuation of Work(Replacement Cost) $ )I t'I 5© Heated/Cooled SF Non-Heated/Cooled • Class of Work: Aew ❑Addition ❑Alteration ❑Repair ❑Move ❑Demo ❑Pool ❑Window/Door • Use of existing/proposed structure(s): f (Commercial ❑Residential • If an existing structure, is a fire sprinkler system installed?: ❑Yes []No • Will trees be removed in association with proposed ro'ect? ❑Yes must submit separate Tree Removal Permit ❑No Describe in detail the type of work to be performed: I V1 C,+ e,e_ "rnA L -P'(c rrlgly-.61r ' Florida Product Approval# Fl._ 030-Pci for multiple products use product approval form Property Owner Information t✓(C Name 0+40 c... ('eaCk Address P( Q 1 c �C �YYGr; City State -,y Zip 3.2-�t - Phone (/Uv�lcr�own r E-Mail Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) Contractor Information / Name of Company '1"7U (ICS Qualifying Agent do kek VY10 Ore Addressv�C City \JAC,K-4l-C State Zip -25;2--2--o-7 Office Phone ( -?,G1 Iuo Zo Job Site Contact Number CZal-..2-(6?-0-7 q-5- State SState Certification/Registration# 6L!f� E-Mail 0(-6,re r (6C(Y1aOJL-Z*]fcAV1 &!� LZ4� 1- Architect Name&Phone# «0"7L,0 7 Engineer's Name& Phone# Workers Compensation Insurer 'gry Aeh,,�leo OR Exempt ❑ Expiration Date Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORpING YOUR NOTICE OF COMMENCEMENT. Y�z� 4 6, Ljn, (Signature of O r or Agent) Signature of Contractor) Signed and sworn to(or affirm d efore e t i /day f Si ned a d sworn to(or affirmed) before me this_L day of ---901 by , c o - •c o r'C G (L ��. (Si natur f Notar TONIGINDLESPERG [__4.�, :ol-F WENDYOKIE `• .; MY COMMISSION#FF 924951 MY COMMISSION#FF 229041 EXPIRES:October 6,2019EXPIRES:June 25,2019 [ ersonally Known OR [ ]Personally Known OR �'�,o��.�P•' Bonded Thru Notary Public Underwrters Bonded Thru Notary Public Underwriters [ ]Produced Identification [ ] Produced Identification Type of Identification: Type of Identification: ----------------------- EXTERIOR RESEARCH&DESIGN, LLC. Certificate of Authorization#9503 TRINITY ERD 353 Christian Street, Unit 13 Oxford,CT 06478 PHONE: (203) 262-9245 EVALUATION REPORT Johns Manville Evaluation Report J8 - P.O. Box 5108 EL9930-R94 Denver,CO 80217 Date of Issuance. (303)978-4879 Revision 9:10/16/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2017)Florida Building Code sections noted herein. DESCRIPTION: JM PVC Single Ply Roof Systems LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes,the referenced Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TRINITY IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus a 31-page Appendix. Prepared by: Robert J.M.Nieminen, P.E. The facimilie seal appearing was authorized by Robert Florida Registration No.59166,Florida DCA ANE1983 """ Nieminen,P.E.ort 1U/,W-2Q1t7.-,.This,dg/s not serve as an electronically signed docuhSent- CERTIFICATION OF INDEPENDENCE: 1. Exterior Research&Design,LLC.d/b/a Trinity I ERD does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a TrinitvlERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither Trinity lERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. O CF Cp Ay TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Single Ply Roof Systems Compliance Statement: JM PVC Single Ply Roof Systems, as produced by the Johns Manville, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4474 2011 1504.7 Impact FM 4470 2012 1507.13.2 Physical Properties ASTM D4434 2012 1523.6.2 Wind TAS 114 2011 3. REFERENCES: Entity Examination Reference Date ACRC,LLC(TST4671) TAS 114 06-045 12/15/2006 ACRC,LLC(TST4671) TAS 114 14-026 11/19/2014 ACRC,LLC(TST4671) TAS114 14-028 11/19/2014 ACRC,LLC(TST4671) TAS 114 14-035 11/25/2014 ACRC,LLC(TST4671) TAS 114 14-042 12/04/2014 ACRC,LLC(TST4671) TAS 114 14-043 12/04/2014 ERD(TST 6049) FM 4470/TAS 114 145020.09.13-1-R1 09/12/2013 ERD(TST 6049) FM 4470/TAS 114 145020.09.13-2-R1 09/12/2013 ERD(TST 6049) FM 4474 SC7565.01.15-2 01/21/2015 ERD(TST 6049) FM 4474 JM-SC11320.03.16 03/10/2016 ERD(TST 6049) FM 4474 JM-SC12145.02.17 02/06/2017 ERD(TST 6049) FM 4474 JM-SC13465.04.17 04/19/2017 ERD(TST 6049) FM 4474 JM-SC13465.08.17 08/25/2017 FM Approvals(TST1867) FM 4470 3009502 12/21/2000 FM Approvals(TST1867) FM 4470 3008869 03/19/2001 FM Approvals(TST1867) FM 4470 3012321 07/29/2002 FM Approvals(TST1867) FM 4470 Letter J.I.3014692 12/20/2002 FM Approvals(TST1867) FM 4470 3015444 07/11/2003 FM Approvals(TST1867) FM 4470 3014692 08/05/2003 FM Approvals(TST1867) FM 4470 3014751 08/27/2003 FM Approvals(TST1867) FM 4470 3018579 10/09/2003 FM Approvals(TST1867) FM 4470 3016629 12/12/2003 FM Approvals(TST1867) FM 4470/4474 3018807 06/25/2004 FM Approvals(TST1867) FM 4470/4474 3025881 08/09/2006 FM Approvals(TST1867) FM 4470/4474 3030351 08/01/2007 FM Approvals(TST1867) FM 4470/4474 Product Revision 797 09/07/2007 FM Approvals(TST1867) FM 4470/4474 797-03290-267 11/02/2007 FM Approvals(TST1867) FM 4470/4474 3028040 11/14/2007 FM Approvals(TST1867) FM 4470/4474 797-03350-267 12/10/2007 FM Approvals(TST1867) FM 4470/4474 797-03425-267 01/16/2008 FM Approvals(TST1867) FM 4470/4474 3035191 05/20/2009 FM Approvals(TST1867) FM 4470/4474 3034810 09/10/2009 FM Approvals(TST1867) FM 4470/4474 3035538 10/02/2009 FM Approvals(TST1867) FM 4470/4474 3037110 10/02/2009 FM Approvals(TST1867) FM 4470/4474 3037540 10/20/2010 FM Approvals(TST1867) FM 4470/4474 3043824 04/06/2012 FM Approvals(TST1867) FM 4470/4474 3044716 10/19/2012 Exterior Research and Design,LLC. Evaluation Report 18230.11.07-R9 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL9930-R9 JM PVC Single Ply Roof Systems Revision 9:10/16/2017 Page 2 of 4 TRINITY ERD Entity Examination Reference Date FM Approvals(TST1867) FM 4470/4474 3046174 04/03/2013 FM Approvals(TST1867) FM 4470/4474 3056303 11/05/2015 FM Approvals(TST1867) FM 4470/4474 3056049 01/13/2016 FM Approvals(TST1867) FM 4470/4474 3058374 04/13/2016 FM Approvals(TST1867) FM 4470/4474 3055845 05/25/2016 FM Approvals(TST1867) FM 4470/4474 3058201 08/29/2016 FM Approvals(TST1867) FM 4470/4474 3060138 01/11/2017 MTI(TST2508) Physical Properties NX2IJOA 06/01/2011 MTI(TST2508) Physical Properties NX2IJOC 06/01/2011 MTI(TST2508) Physical Properties NX2IJOB 07/20/2011 MTI(TST2508) Physical Properties CX23G3A 07/16/2015 PRI(TST 5878) FM 4470/4474 JMC-163-02-01 09/06/2013 PRI(TST 5878) FM 4470/4474 JMC-193-02-OIA 04/28/2014 PRI(TST 5878) FM 4470/4474 JMC-246-02-01 03/29/2016 UL LLC(QUA9625) Quality Control R10167,Service Confirmation Exp.06/23/2019 4. PRODUCT DESCRIPTION: The following roof covers are mechanically attached or fully adhered to Approved substrates using fasteners, stress plates and adhesives,as outlined in the Limitat�pns/Conditions of Use herein. .2 mm), -mil(1.5 mm)fir 80 mil (2.0 mm)thick,polyester scrim reinforced,single- ply roof membrane coated with a proprietary PVC compound; meets ASTM D4434-12,Type III. JM PVC SD Plus is a nominal 50-mil (1.2 mm), 60-mil (1.5 mm) or 80 mil (2.0 mm) thick, polyester scrim reinforced,single-ply roof membrane coated with a proprietary PVC compound; meets ASTM D4434-12,Type III. .- JM PVC Fleece Backed is a nominal 50-mil (1.2 mm) or 60-mil (1.5 mm)thick, polyester scrim reinforced, single- ply roof membrane coated with a proprietary PVC compound and a felt backing;meets ASTM D4434-12,Type III. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report,or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in HVHZ jurisdictions. 5.3 Refer to a current UL Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations,foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations,the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip-bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. Exterior Research and Design,I.I.C. Evaluation Report 18230.11.07-R9 Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL9930-R9 JM PVC Single Ply Roof Systems Revision 9:10/16/2017 Page 3 of 4 TRINITY ERD 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re-roof(tear off)or recover installation,the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 611320-3. 6. INSTALLATION: 6.1 JIM PVC Single Ply Roof Systems shall be installed in accordance with Johns Manville published installation instructions,subject to the Limitations/Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 6.3 For mechanically fastened membrane systems(Type D) over profiled steel deck, membrane shall be installed running perpendicular to steel deck flutes. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. 9. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625;(847)664-3623; LeAnna.Gradecki@ul.com -THE 31-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT- Exterior Research and Design,LLC. Evaluation Report J8230.11.07-R9 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL9930-R9 JM PVC Single Ply Roof Systems Revision 9:10/16/2017 Page 4 of 4 TRINITY ERD APPENDIX 1:ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A Wood New,Reroof(Tear-Off),Recover A Bonded Insulation,Bonded Roof Cover 4 IB Wood New,Reroof(Tear-0ff),Recover C-1 Mechanically Attached Insulation Bonded Raaf Cover 4-5 1C Wood New,Reroof(Tear-Off),Recover C-2 Mechanically Attached Insulation,Plate-Bonded Roof Cover 6 1D Wood New,Reroof(Tear-Off),Recover D Insulated,Mechanically Attached Roof Cover 6 2A Steel or Structural Concrete New,Reroof(Tear-Off),Recover B-1 Mechanically Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 7-8 2B Steel or Structural Concrete New,Reraaf(Tear-Oft)or Recover B-2 Mechanically Attached Thermal Barrier,Bonded Temp Roof,Bonded Insulation,Bonded Roof Cover 9-10 2C Steel New,Reroof(Tear-Off),Recover C-1 Mechanically Attached Insulation,Bonded Roof Cover 11-14 2D Steel New,Reroof(Tear-Off),Recover C-2 Mechanically Attached Insulation,Plate-Bonded Roof Cover 35 2E Steel New,Reroof(Tear-Off),Recover D-1 Insulated,Mechanically Attached Roof Cover 16-17 2F Steel New,Reroof(Tear-Off),Recover D-2 Insulated,Mechanically Attached Base Sheet,Bonded Roof Cover 18 3A Structural Concrete New,Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 19-22 3B Structural Concrete New,Reroof(Tear-Off),Recover C-2 Mech.Attached Insulation,Plate-Bonded Roof Cover 23 3C Structural Concrete New,Reroof(Tear-Off),Recover D Insulated,Mechanically Attached Roof Cover 23-24 3D Structural Concrete New,Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 24 4A LWIC New,Reroof(Tear-Off) A Bonded Insulation,Bonded Roof Cover 25 46 LWIC New,Reroof(Tear-Off) F LWC to Deck,Bonded Roof Cover 25 4C LWIC New,Reroof(Tear-Off) F Vapor Barrier to Deck,LWC to Vapor Barrier,Bonded Roof Cover 26 SA CWF New,Reroof(Tear-Off) A Bonded Insulation,Bonded Roof Cover 27 SB CWF New,Reroof(Tear-Off) C Mechanically Attached Insulation,Bonded Roof Cover 27 6A Gypsum Reroof(Tear-Off) A Bonded Insulation,Bonded Roof Cover 28 66 Gypsum Reroof(Tear-Off) C Mechanically Attached Insulation,Bonded Roof Cover 28 7A Various Recover A Bonded Insulation,Bonded Roof Cover 29 78 Various Recover Over Existing Metal Roof C-2 Mach.Attached Insulation,Plate-Bonded Roof Cover 30 7C Various Recover Over Existing Metal Roof D Insulated,Mechanically Attached Roof Cover 31 7D Various Recover F Non-Insulated,Bonded Roof Cover 31 The following notes apply to the systems outlined herein: 1. The evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Fasteners shall be of sufficient length for the following engagements: Wood Deck: UltraFast Fasteners or All Purpose Fasteners with UltraFast Metal Plates.Minimum%-inch plywood penetration or minimum 1-inch wood plank embedment. Steel Deck: UltmFast Fasteners or All Purpose Fasteners with UltraFast Metal Plates.Minimum%-inch steel penetration,engage the top flute of the steel deck. I Structural Concrete: All Purpose Fasteners with UltraFast Metal Plates or Structural Concrete Fasteners with UltmFast Metal Plates(flat bottom only). Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer's published installation instructions 3. Unless otherwise noted,insulation may be any one layer or combination of polyisocyanumte,polystyrene,wood fiberboard,perlite or gypsum-based roof board that meets the CIA requirements of F.A.C.Rule 61G20- 3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC Chapter 26,when installed with the roof cover. Exterior Research and Design,LLC.d/b/a Trinity(ERD Evaluation Report 18230.11.07-R9 for FL9930-R9 Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION Revision 9:10/16/2017 Prepared by:Robert Nieminen,PE-59166 1M PVC Single Ply Rod Systems;(303)9794979 Appendix 1,Page 1 of 31 TRINITY ERD 4. Minimum 200 psi,minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D(mechanically attached membrane),whereby the membrane fasteners are installed through the LWIC to engage the structural steel or concrete deck.The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FOC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5. Preliminary insulation attachment for System Type D=Minimum four fasteners per 4 x 8 ft board or minimum two fasteners per 4 x 4 ft board. 6. Unless otherwise noted,insulation adhesive application rates are as follows.Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted in the manufacturer's published instructions. Hot asphalt[HA): Full coverage at 25 lbs/sq. .JM MBR Bonding Adhesive(MBR-BA]: Continuous%-inch wide ribbons,12-inch o.c.or full coverage at 1.5 gal/square .JM One-Step Foamable Adhesive(JM-OSFA]: Continuous A-inch beads,12-inch o.c. JM Roofing System Urethane Adhesive(1M-RSUA): Continuous 0.5 to 0.75-inch wide ribbons,12-inch o.c. JM Two-Part Urethane Insulation Adhesive[UTA-TWO-PART]: Continuous%-inch wide ribbons,12-inch o.c.JM Green Two-Port Urethane Insulation Adhesive may be used where UTA-TWO-FART is referenced. .ICP Adhesives CR-20: Continuous 2''A to 31S-inch ribbons,12-inch o.c. .Note:When multiple layersls)of insulation and/or coverboard are installed in ribbon-applied adhesive,board pints shall be staggered. Note:The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 7. Unless otherwise noted,all insulations are flat stock or taper board of the minimum thickness noted.Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings in the tables;rather if MDP listing below meets or exceeds that listed for a particular system in the tables,then the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table: .1M One-Step Foamable Adhesive(1M-OSFA]: MDP -157.5 psf (Min.0.5-inch thick) i 1M Roofing System Urethane Adhesive(JM-RSUA): MDP -157.5 psf (Min.0.5-inch thick) .JM Two-Part Urethane Insulation Adhesive[UTA-TWO-PART]: MDP -315.0 psf (Min.0.5-inch thick ENRGY 3 orJM ISO 3) .ICP Adhesives CR-20: MDP -117.5 psf (Min.1.0-inch thick) 8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FOC Chapter 16,and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD-1,FM Loss Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 or RAS 137.Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29(January 2016)for Zone 2/3 enhancements. 10. For assemblies with all components fully bonded in place,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16,and no rational analysis is permitted. 11. For mechanically attached components over existing decks,fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system.Testing shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For existing substrates in a bonded recover or re-roof installation,the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system(for recover)shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction,as documented through field uplift testing in accordance with ANSI/SPRI IA-1,ASTM E907,FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For System Type D,steel deck applications,the roof membrane shall be run with its length perpendicular to the steel deck flutes. 14. For Recover Applications using System Type D,the insulation is optional.Alternatively,Invinsa Roof Board,Dens Deck,Dens Deck Prime,DEXcell FA Glass Mat Roof Board or SECUROCK Gypsum-Fiber Roof Board may be used as a separator board,preliminarily attached prior to roof cover installation.The existing roof system shall be suitable for a recover application. 15. LWIC shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced,refer to current LWIC Product Approval for specific deck construction and limitations. For systems where specific LWIC is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1,Point 1. Exterior Research and Design,I.I.C.d/b/a Trinity(ERD Evaluation Report 18230.11.07-R9 for F1.9930-1119 Certificate of Authorization 119503 6'EDITION(2017)FBC NON-HVHZ EVALUATION Revision 9:10/16/2017 Prepared by: Robert Niernmen,PE-59166 JM PVC Single Ply Roof Systems;(303)978-4879 Appendix 1,Page 2 of 31 TRINITY ERD 16. For adhered membrane systems,side laps shall be minimum 3-inch wide sealed with min.1.5-inch heat weld. Membrane adhesive application rates are as follows: ADHESIVE APPuCAT1oN RATES Membrane Adhesive Method Rate JM PVC or JM PVC SO Plus JM PVC Membrane Adhesive(Low VOC)[JM PVC MA-LVOC) Contact(both sides) 1.67 gal/square(h applied to substrate and h applied to membrane) JM PVC SD Plus 1M PVC Membrane Adhesive(Low Solvent Based)[JM PVC MA-LSB) Contact(both sides) 1.1 to 2.0 gal/square['A applied to substrate and%applied to membrane) JM PVC or JM PVC 50 Plus JM PVC Membrane Adhesive(Water Based)[JM PVC MA-WB) Contact(both sides) 1.10 gal/square h applied to substrate and'A applied to membrane)for use over RetroPlus Board JM PVC or JM PVC SO Plus TACC LA432 Contact(both sides) 2.0 gal/square('h applied to substrate and'A applied to membrane) 1M PVC TACC FA-636 Contact(both sides) 1.34 gal/square('A applied to substrate and h applied to membrane) 1M PVC 1M PVC Membrane Adhesive(Water Based)[JM PVC MA-WB] Wet lay(substrate) 0.67 gal/square JM PVC Fleece Backed JM PVC Membrane Adhesive(Low VOC)[JM PVC MA-LVOC] Wet lay(substrate) 1 gal/square JM PVC Fleece Backed 1M PVC Membrane Adhesive(Water Based)[JM PVC MA-WB] Wet lay(substrate) 1 gal/square 1M PVC Fleece Backed MBR Low VOC Membrane Adhesive at 2-2.5 al/square Wet lay(substrate) 2 to 2.5 al/square JM PVC Fleece Backed JM Roofing System Urethane Adhesive(1M-RSUA) Wet lay(substrate) 0.5 to 0.75-inch wide ribbons spaced as noted in tables herein. 1M Single Ply Two Part Urethane Insulation Adhesive(JM-SP-UTA-TWO- 1M PVC Fleece Backed pART) Wet lay(substrate) 0.5 to 0.75-inch wide ribbons spaced as noted in tables herein. JM PVC Fleece Backed Hot asphalt full mop Wet lay(substrate) 25 lbs/square. 17. For Hybrid Systems,consisting of JM PVC Fleece Backed applied in hot-asphalt full-mop over modified bitumen base ply(s),the following base ply references apply. JOINS MANVILLE BASE/PLY SHEETS FOR USE IN Hva=JM PVC FLEECE I11&c ED APPIJCATcm Reference Layer Material Application BP-AA(Base and Ply sheets, Base One or more GlasBase Plus,PermaPly 28 Hot asphalt at 20-40 lbs/square Asphalt-Applied) Ply One or more GlasPly IV,GlasPly Premier,GlasBase Plus,PermaPly 28 SBS-AA(SBS,Asphalt-Applied) Base/Ply: One or more DynaPly T3,DynaBase,DynaBase XT,DynaBase PR,DynaLastic 180 S,DynaLastic 250 S,DynaLastic 250 FR S Hot asphalt at 2040 lbs/square SBS-TA(SBS,Torch-Applied) Base/Ply: One or more DynaBase HW,DynaWeld Base,DynaWeld 180 5 Torch-Applied 18. Modified bitumen vapor barrier options for use over structural concrete deck followed by adhered insulation applied as follows carry the following Maximum Design Pressure(MDP)limitations. The lesser of the MDP listings below vs.those in Table 3A applies: `-VAPOR BARRIER OPTIONS;STRUCTURAL CONCRETE DEcic,FoLLONED By ADHERED INSULATION PER TABLE 3A: Option p Primer Vapor Barrier Insulation Adhesive MDP (sf) 1 ASTM D41 Two plies GlasPly IV,GlasPly Premier in hot asphalt JM Roofing System Urethane Adhesive(RSUA),12-inch o.c. -180.0 2 ASTM D41 Two plies GlasPly IV,GlasPly Premier in hot asphalt JM One-Step Foamable Adhesive(OSFA),12-inch o.c. -180.0 3 ASTM D41 WnaPN Tl,DynaBase,DynaBase XT,DynaBase PR,DynaLastic 180 S,DynaLastic 250 S,Dynalastic 1M One-Step Foamable Adhesive(OSFA),12-inch o.c. -180.0 250 FR 5 in hot asphalt or DynaBase HW,DynaWeld Base,DynaWeld 180 5 torch-applied 4 JM SA Primer Low VOC 1M Vapor Barrier SA,self-adhered 1M Two-Part Urethane Insulation Adhesive(UTA-2),12-inch o.c. -277.5 5 JM SA Primer Low VOC 1M Vapor Barrier SA,self-adhered 1M Roofing System Urethane Adhesive[RSUA),12-inch o.c. -277.5 DynaPly Tl,DynaBase,DynaBase XT,DynaBase PR,Dynalastic 180 S,DynaLastic 250 S,DynaLastic 6 ASTM D41 250 FR S in hot asphalt or DynaBase HW,DynaWeld Base,DynaWeld 180 S torch-applied 1M Two-Part Urethane Insulation Adhesive(UTA-2),12-inch o.c. -277.5 7 ASTM D41 DynaPly Tl,DynaBase,DynaBase XT,DynaBase PR,DynaLastic 180 S,DynaLastic 250 5,DynaLastic JM Roofing System Urethane Adhesive(RSUA),12-inch o.c. -277.5 250 FR Sin hot asphalt 8 ASTM D41 DynaBase HW,DynaWeld Base,DynaWeld 180 S torch-applied JM Roofing System Urethane Adhesive(RSUA),12-inch c.c. -292.5 19. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind pressures. Exterior Research and Design,U.C.d/b/a Trinity[ERD Evaluation Report 18230.11.07-R9 for FL9930-R9 Certrficate of Authorization 1!9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION Revision 9:10/16/2017 Prepared by:Robert Nieminen,PE-59166 1M PVC Single Ply Roof Systems;(303)978-4879 Appendix 1,Page 3 of 31 TRINITY ERD TABLE 1A:WOOD DECKS-NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A:BONDED INSULATION,BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer MDP No Deck(Nate 1) Type Attach Type Attach Roof Cover/Adhesive (Psf) W-1. Min.15/32"BCX plywood or OSB One or more layers min.1.5-inch CR-20 Min.0.25-inch Invinsa Roof Board CR-20 JM PVC/TACC LA 432,TACC FA _52.5 ENRGY 3 1 1 636,1M PVC MA-LVOC TABLE IB:WOOD DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEMTYPEC-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Deck(Note 1) Base Insulation Layer Top Insulation Layer Roof Cover/Adhesive MDP No. Type Fasteners Attach (Note 16) (psf) JM PVCAPPLicm m Min.23/32"(nominal Min.0.25-inch Dens Deck or SECUROCK Gypsum- UltraFast Pre-Assembled Phillips or Fiber Roof Board followed by min.1.5-inch ENRGY 3, UltraFast Pre-Assembled Hex or 1 per 2 W-2. %")thick plywood or ENRGY 3 AGF,ENRGY 3 CGF,1M ISO 3 or 25 PSI, Min.0.25-inch Dens Deck UltraFast Square Recessed Metal ft2 11M PVC/TACC LA 432, M PVC MA-W8,JM -30.0' wood plank ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI CGF,loose laid Plate with UltraFast#12 or#14 PVC MA-LVOC Min.0.25-inch Dens Deck or SECUROCK Gypsum- Min.23/32"(nominal 1M PVC/TACC LA 432, W-3. %')thick plywood or Fiber Roof Board followed by min.1.5-inch ENRGY 3, Min.0.25-inch Dens Deck OMG 3 in.#12Galo#1 Steel Plates 1 per JM PVC MA-WB,JM -30.0' wood plank 3 AGF,ENRGY 3 CGF, 150 3 or 25 PSI, with OMG#12 or#14 HD 2.67 ft2 PVC MA-LVOC ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI CGF,loose laid Min.0.25-inch Dens Deck or SECUROCK Gypsum- 1M PVC/TACC LA 432, Min.23/32"(nominal Fiber Roof Board followed by min.1.5-inch ENRGY 3, OMG 3 in.Galvalume Steel Plates 1 per 3.2 W3. %")thick plywood or ENRGY 3 AGF,ENRGY 3 CGF,1M ISO 3 or 25 PSI, Min.0.5-inch Dens Deck with OMG#12 or#14 HD ft2 JM PVC MA-WB,JM -30.0' wood plank ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI CGF,loose laid PVC MA-LVOC Min.19/32"APA Min.0.25-inch DEXcell FA Glass W 5 rated OSB or min. (Optional)One or more layers,any type,thickness or Mat Roof Board or Min.7/16-inch All Purpose Fasteners with Uhrafast 1 per JM PVC/JM PVC MA- -37.5" 15/32"APA rated combination,loose laid DEXcell Cement Roof Board Square Metal Plates 2.67 ft2 WB,JM PVC MA-LVOC plywood Min.0.25-inch Dens Deck or SECUROCK Gypsum- UltraFast Pre-Assembled Phillips or Min.23/32"(nominal 1M PVC/TACC LA 432, W-6. W)thick plywood or Fiber Roof Board followed by min.1.5-inch ENRGY 3, Min.0.25-inch Dens Deck UltraFast Pre-Assembled Hex or 1 per 1.8 JM PVC MA-WB,JM -45.0' wood plank ENRGY 3 AGF,ENRGY 3 CGF,JM ISO 3 or 25 PSI, UltraFast Square Recessed Metal ft2 PVC MA-LVOC ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI CGF,loose laid Plate with UltraFast#12 or#14 Min.0.25-inch Dens Deck or SECUROCK Gypsum- Min.23/32"(nominal JM PVC/TACC LA ,J 432, W-7. %")thick plywood or Fiber Roof Board followed by min.1.5-inch ENRGY 3, Min.0.25-inch Dens Deck OMG 3 in.Gat#12 of#14 Steel Plates 1 per 1M PVC MA-WB,1M -45.0' wood plank ENRGY 3 AGF,ENRGY 3 CGF,1M I50 3 or 25 PSI, with OMG#12 or#14 HD 2.13 ft2 PVC MA-LVOC ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI CGF,loose laid Min.0.25-inch Dens Deck or SECUROCK Gypsum- Min.23/32"(nominal JM PVC/TACC LA 432, Fiber Roof Board followed by min.1.5-inch ENRGY 3, Min.5/8-inch Dens Deck or Dens OMG 3 in.Galvalume Steel Plates 1 per 4 W-8. W)thick plywood or ENRGY 3 AGF,ENRGY 3 CGF,JM ISO 3 or 25 PSI, Deck Prime with OMG#12 or#14 HD ft2 1M PVC MA-WB,JIM 35.0' wood plank ENRGY 3 25 PSI AGF,ENRGY 3 25 PSI CGF,loose laid PVC MA-LVOC Exterior Research and Design,LLC.d/b/a Trinity(ERD Evaluation Report 18230.11.07-R9 for FL9930-R9 Certificate of Autharization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION Revision 9:10/16/2017 Prepared by:Robert Nieminen,PE-59166 JM PVC Single Ply Roof Systems;(303)978-4879 Appendix 1,Page 4 of 31 TRINITY ERD TABLE IB:WOOD DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE C-1:MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER System Top Insulation Layer Roof Cover/Adhesive MDP Deck(Note 1) Base Insulation Layer No. Type Fasteners Attach (Note 161 (psf) Min.15/32"TECO (Optional)One or more layers,an Min.0.25-inch DEXcell FA Glass W-9. rated plywood or Y Y type,thickness or Mat Roof Board or Min.7/16-inch All Purpose Fasteners with UltreFast 1 per 1M PVC/1M PVC MA- -45.0' OSB combination,loose laid DEXcell Cement Roof Board Square Metal Plates 2.67 112 WB,1M PVC MA-LVOC Min.1.5-inch ENRGY 3,ENRGY 3 Min.7/16"APA rated AGF,ENRGY 3 CGF,25 PSI,ENRGY (Optional)One or more layers,any type,thickness or 3 25 PSI AGF,ENRGY 3 25 PSI All Purpose Fasteners with UltraFast 1 per 2 JM PVC/JM PVC MA- W-10. OSB rated min.ted plyywoodwood 15/32" combination,loose laid CGF,ValuTherm,ValuTherm AGF, Square Metal Plates ft2 WB,1M PVC MA-LVOC -45.0' APA a ValuTherm CGF,ValuTherm 25 PSI AGF,ValuTherm 25 PSI CGF Min.2-inch ENRGY 3,ENRGY 3 AGF,ENRGY 3 CGF,25 PSI,ENRGY UltraFast Pre-Assembled Phillips or Min.23/32'(nominal JM PVC/TALC LA 432, Min.0.25-inch Dens Deck or SECU ROCK Gypsum- 3 25 P51 AGF,ENRGY 325 PSI UltraFast Pre-Assembled Hex or 1 per4 W-11. %")thick plywood or Fiber Roof Board CGF,ValuTherm,ValuTherm AGF, Ultra Fast Square Recessed Metal ft2 JM PVC MA-WB,JM -45.0' wood plank ValuTherm CGF,ValuTherm 25 Plate with UltraFast#12 ort114 PVC MA-LVOC PSI AGF,ValuTherm 25 PSI CGF 1M PVC FLEECE BACKED AppucAnoNs: Min.19/32'APA Min.0.25-inch DEXcell FA Glass W-12. rated OSB or min. )Optional)One or more layers,any type,thickness or Mat Roof Board or Min.7/16-inch All Purpose Fasteners with UltraFast 1 per JM PVC Fleece Backed -37.5' 15/32"APA rated combination,loose laid DEXcell Cement Roof Board Square Metal Plates 2.67 ft2 /1M PVC MA-WB plywood Min.15/32'TECO Min.0.25-inch DEXcell FA Glass W-13. rated plywood or (Optional)One or more layers,any type,thickness or Mat Roof Board or Min.7/16-inch All Purpose Fasteners with UltraFast 1 per 1M PVC Fleece Backed -45.0' OSB combination,loose laid DEXcell Cement Roof Board Square Metal Plates 2.67 ft2 /JM PVC MA-WB Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report 18230.11.07-R9 for FL9930-R9 CertUrcate of Authorization#9503 br'EDITION(2017)FBC NON-HVHZ EVALUATION Revision 9:10/16/2017 Prepared by:Robert Nieminen,PE-59166 JM PVC Single Ply Roof Systems;(303)978-4879 Appendix 1,Page 5 of 31 TRINITY ERS TABLE IC:WOOD DECKS-NEWCONSTRUCTION,REROOFITEAR-OFF)ORRECOVER SYSTEM TYPE C-2:MECHANICALLY ATTACHED MISULATION,PLATE-BONDED ROOF COVER System I Deck Attach No. INob t) InsuHabon Layer FRoof Cover MDP asterren psnsRy IPM One or more Min 60-Mil JM PVC bonded to JM PVC RhmoPiates W-id Min 19132-APA rated OSE layers.any R Purpose Fasteners wRh JM PVC I per 5.33 ft-(6 parts per 4x6 h board) wth RhmoSond Ponabie Bo Tool combrrlatwn RhxlOP!ates ^tl"19 Per .. manufacturers PLb"hed msirt Mons Min 15132"A?A ratetl One cr more layers,any AB Pt;rpose fasteners with JM PVC Min 6C-ml JM PVC berdeo to JM PVC RhmoPlales W-15 1 per 2 67 fl'(16'x 24"grid) Aith Rni B nd Pcrtatie B Too per plywood a7 24"Spar xmbrnatipn RlarlpPlaYs �'�'g -. manufacturers pubksbed rnstruebona. Al Purpose Fasteners wqh.PAI PVC Mir.Fc-m:i JM f"/C ocrldeob JM PVC RrmroPtates Mm A 16'APA rated OSB One or more layers.arty a'c c rows 3par..ed 41r-0 c VV-16. col"Itmulbon RhirroPlales msM=tx ro er9a9a F dnh Rtnc8o,d Portable Bor dng Taos.per 45 QA kk 3rier!Qr5 6kn 15/37'TECO rated One or more'avers ar/y M Purpose=as-er,ers wttlr!kl PVC PVC Rh;rtoPWtes W-17 OSB or APA rated I p?r=Y-24 z 24 jrci wro8orrd Ppttable Tpcl ce• 45 Plywood ca^brim on Rlrmoplates mar R1larsMxirWrer's put#shed arsBIr s TABLE 1D:WOOD DECKS-NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER SYSTEM TYPE D:INSULATED,MECHANICALLY ATTACHED ROOF COVER SYrwm YtsWUew Roof Cover DecRWP til k(Nob t i Base No. Bs;,aya, TN Lsysr Attach Membrane Fast-- Attach Mm.23t32'(nominai:") Min.0.25�ncr Dens Deca Min 1 5-.rch EWRGY 3.ENRGY 3AGF, Prefim Min 50 mil, Hrgr Load 1M"tl+oc mtarr 5-M&w+de W-18 duck plywood or wood or SECUROCK Gypsu- ENRGY 3CGF.25PSi,ENRCY325PSi attach JM PVC €araerers rrtlfr lath 3pacetl 73-reps o: Lap -3(?U plank Fiber Roof Board AGF.ENRGY 3 25 PSI CGF Mqh;,oft Plays seated with 2—Th treat ado Min 23132"Inti—Der!%. Mm 0 25-mch Dem Deck Mm 15-mch E11RGY 3,ENRGY 3AGF, High moose 12-,ncr o c.wntw'5-src1 woe, Iv- s 9"ck pywood ar wood a SECUROCK Gypsum- ENRGY3CGF,25PSl,ENRGY325PS1 prekm ( ksr 60 mp `c attach JM PVC Fasteners Load Pka �spaced-arch h of taps 45 p1aMr Frber Roc!Board AGF,ENRGY 3 25 PSI CGF High trAd Plates sealed w3M 2-.nLl+had!vrefa Extort-Research arra Design,LLC.d10q Trwrity HERD Erawateml RepOr J8230 1' 07-R5 to FLtg7s4i! r"llb"✓v 11 Iwlrnn-orrrtn-:93913 f"EDRION IM71 FBC MN41VHZ EVALUATION Re'reiMn 4 IQ 15_X-7 P"epareo by.Roden Nreminer PE-591,66 JM PVC SW4-Py Roof System;I3a3)97"W9 Append,I Page 6 of3' JIB PVC- 60 mil MIN Thermoplastl of vi Membrane Johns Manville 4,Meets the requirements of ASTM D 4434,Type III Cnmponem Features and Components M Advanced Solid Phase Polymer Formulation:Uses the optimal amount of DuPont"Elvaloy` KEE(Ketone Ethylene Ester)polymer to:Ensure plasticizer retention;Extend roof life(exceeds 39,000 hours of accelerated weathering testing(ASTM 6 154requires5,000hourst and to reduce maintenance costs. Patented Aramid-Reinforced Edge:Aramid fiber is woven into the fastening side of all full rolls of PVC membrane. Non-wicking Reinforced Polyester Scrim:Our fully integrated manufacturing process adds tensile strength and toughness. Due to the non-wicking edge,sealant is not required. Colors* Excellent Chemical Resistance:JM PVC is inherently resistant to White oils,air conditioning coolants,fuels and grease. All colors not available asstandard stocked items inall size contigurations. Please call for minimums and lead times. JM Membranes are designed with a cap,core,and bottom in order to utilize recycled content. The cap,or top-side is produced with non-recycled content,and should always be install PROVIDE WALK PADS AS facing up.The cap is identified hythe lap line and production code. SPECIFIED IN THE SPECIFICATION System Compatibility This product maybe used as a component in the following systems.Please reference product application for specific installation methods and information. Do not use in Multi-Ply systems Compatible with the selected Single Ply systems above Key: HA = Hot Applied CA = Cold Applied HW= Heat Weldable SA = Self Adhered MF = Mechanically Fastened AD = Adhered BA = Ballasted Energy and the Environment Installation/Application Standard Reflecitivity EmissMN CRRC" White Initial 0.86 0.86 & 00 3 Yr.Aged 0.70 0.82 CA Tide 24 White Pass 0.86 0.86 ENERGY White Initial 0.86 0.86 STAR 3 Yr.Aged 0.70 Adhered Mechanically Hot Air Weld Fastened LEED° Initial 108 White (SRI) 3Yr.Aged 84 Refer to JM PVC application guides and detail drawings Recycled Post-consumer 0% for Instructions. Content Post-industrial 0%-10% The LEED'Solar Reflectance Index(SRI).s calculated per ASTM E1980. Packaging and Dim Q416. Peak Advantages Guarantee Information Size Coverage Product Thickness Terms 3.25'x 100'(1 m x 30.48 m) 325 ft'(30.19 m') 60mil MIN 5,10,15 or 20 rNDL __d 6.5'x100'(1.98mx30.48m) 50ft�(60.38m') Guarantee terms are for mechanically fastened and adhered systems. 10'it 100'(3.05 m x 30.48 m) ft`192.9 m`) Codes and Approvals wdd,5 3.25' 10' p551F/E Rolls per Pallet 18 Ir 9 9 c7 F M �AritnoEcouHrr Pallet Weight-Ib(k ) 265411203.8) 2654(1203.8) 4225 11916.4) C U� US Mian-o.n�co��rr Pallets per Truck* 17 17 8 APPROVED P,o�tt c­,aov.d Producing Locations Pawtucket,RI and Lancaster,SC 'Assumes 48'flatbed truck. Refer to the Safety Data Sheet and product label prior to using this product. The Safety Data Sheets available by calling(800)922-5922 or on the Web at www.lm.com/roofing. RS-9275 2-181Reulaces11-'h JM PVC - 60 mil MIN Johns Manville Thermoplastic Polyvinyl Chloride Membrane Meets the requirements of ASTM Q 4434,Type III Tested Physical Properties Properties PI mil MIN Breaking Strength,min,Ib/in.(N) D 751 200(890) 361(1,606) Elongation at Break,min% D 751 15 30 s Tearing Strength,min,lbf/in.(N) D 751 45(200) 110.6(492) H Seam Strength,min,%of breaking strength D 751 75 100 Static Puncture Resistance,Ibf(kg) 05602 Pass®33(15) Pass Dynamic Puncture Resistance,J D 5635 Pass®20 Pass Thickness,min,in. D 751 +/-10%from Nominal 0.060(Minimal) t Thickness Over Scrim,min,in. D 7635 0.016 0.027 S Water Absorption,max,% D 570 modified 3.0 0.12 Low Temperature Bend,°F D 2136 No Cracks®-40°F Pass o Properties after Neat Aging,min D 3045 56 days 0176'F cBreaking Strength,%(after aging) D 751 90 91 Elongation,%(after aging) D 751 90 94 Linear Dimensional Change,max,%(after 6 hrs®176°F) D 1204 0.5 0.24 Accelerated Weathering,mire G 151&6154 5,000 hrs Cracking(®7x magnification) G 154 No Cracks Pass 4>39,000 hrs Discoloration(by observation) G 154 Negligible Negligible _ Crazing(®7x magnification) G 154 No Crazing Pass®>39,000 hrs g Moisture Vapor Transmission ASTM E 96,Proc B, 0.02 g/m'per 24 hrs Method A Note:60 mil MIN products offer a tighter thickness tolerance and will be manufactured no less than 60 mil. Refer to the Safety Data Sheet and product label prior to using this product. The Safety Data Sheet is available by calling(800)922-5922 or on the Web at vwvw.im.com/roofing. RS-9275 2-18(Replaces 11-17) Flat & Inered ENHGY 3Johns Manville J Polyisocyanurate Roof Insulation Meets the requirements of ASTM C 1289,Type II,Class 1, Grade 2(20 psi) _ Cnmpnnerq •ENRGY 3/Tapered ENRGY 3 Flat v"—.i Grade 3(25 psi) •ENRGY 3 25 PSI/Tapered ENRGY 3 25 PSI p Single Pry Features and Components " � � TM__ Glass-Reinforced Facers:Provides rigidity and resistance to FIT indentation and crushing,and are compatible with BUR,modified Glass-Reinforced Niyn re mal bitumen and single ply membrane systems. Facers TP Closed Cell Polyisocyanurate Foam Core:Provides high R-value per dueled inch in built-up,modified bitumen,metal roof and single ply roof systems,and approved for direct application to steel decks. '�'� ATTACH PER MANUFACTURER Tapered Closed cell REQUIREMENTS LISTED IN THE TRINITY ERD Polyisocyanurate Foam Core EVLUATION REPORT FOR SYSTEM W-17 System Compatibility This product maybe used as a component in the following systems.Please reference product application for speck installation methods and information. .r PVC .D mmm mmMF FA MF FA III FA BA Compatible with the selected Multi-Ply systems above I ICompatible with all Staple Ply system Key: HA = Hot Applied CA= Cold Applied HW= Heat Weldable SA= Self Adhered MF= Mechanically Fastened FA= Fully Adhered BA= Ballasted Energy and the Environment Installation/Application LEER® Recycled Content Varies with thickness,see Product Data �M and Packaging table on next page. U ,� Produced with a pentane blowing agent with zero ozone depletion ° and virtually no global warming potential. w'� HotAsphah Urethane Mechanically Loose Laid Adhesive Fastened Peak Advantage" Guarantee Information Refer to the application instructions guidelines for proper utilization Systems ofthis product For use in approved JM Peak Advantage Roofing Guarantees Flute Span: Width of Rib Opening: Up to 2'/a" Up to 3'/e" Up to 4'/z' 16.67 cm) 18.57 cm) (11.11 cm) Codes and Approvals Insulation Thickness(mint 1.T(2.54 cm) 1.2"(3.05 cm) 1.3"(3.30 cm) `` C U� OS SSS IF/,, o FM RunwAoe�ourrn tyMPackaging and Dimensions S PIark' Miam-0ade ty The " .L wlue APPROVED Product conn.(CounApProwd pl Sizes,Sit , 4'x 4' 4'x f1' Fiat (1.22 m x 1.22 m) 1 (1.22 m x 2.44 m) • FMS Standards 4450/4470 Approvals(refer to FM RoofNav") 2 4'x 4' Tapered Size (1.22 m x 1.22 m) • UL*Standard 790,263 and 1256(refer to UL Roofing Materials system directory) Producing Locations Bremen,IN Cornwall,ONT Fernley,NV • Meets the requirements of CAN/ULC S704,Type 2&3,Class 3Stocking Locations' Grand Prairie,TX Southgate,CA TracyCA Hazleton,PA Jacksonville,FL , •California Code of Regulations,Title 24,Insulation Quality 1.For available thicknesses,see Product Data and Packaging table on page 2 of this data Standard License#TI-1341 sheet.Other sizes available by special request,some sizes are not stocked and special •Third-party certification with the PIMA Quality Mark"for order with minimum order quantities.Contact your JM Sales Representative for details. 2.Tapered ENRGY 3 and Tapered ENRGY 3 25 PSI are available in thicknesses of 12"tof'. Long-Term Thermal Resistance(LTTR)values Available profiles are shown on page 3 of this data sheet.In some regions extended panels are also available. Refer to the Safe for Use instructions and product label prior to using this product 3.Not all sizes,thicknesses,and products are stocked at all locations,please call Customer The Safe for Use instructions are available by calling(800)922-5922 or on the Web at Service at 1-877-766-3295. www.im.com/roofing. Note:Technical information on this data sheet is intended to be used as a general guideline only and is subject to change without notice. Contact your JM Sales Representative for further details. RS-5137 10-17(Replaces 6-171 flat INHGY 3johnsMainvilie � Polyisocyanurate Roof Insulation Typical Physical Properties Test ASTM Values Tensile Strength C 209 500 psf(24 kPa)(min),730 psf 135 kPa)(nom) Compressive Resistance 10%Consolidation D 1621 Grade 2:20 psi(138 kPa►, Grade 3:25 psi(172 kPa)(min) y Dimensional Stability Change,/length&width) D 2126 0.5%(nom), 2%(max) 12 Moisture Vapor Permeance E 96 <+1.0%perm,57.5 ng/(Pa*s*m2), 1.5 Perm,65.8n Pa*s*m1 Water Absorption C 209 1.0%(max) e; Service Temperature D1623 -100°F-250°F (-73°C-121°C) 3 Flame Spread,(foam core) E 84 20-30(nom),75(max) Smoke Developed,(foam core) E 84 55-250(nom), 450(max) Product Data and Packaging 11313=1EFTTAMq mm (hrft'*°F)/BTU nr4*Q/U %Pror %.Tpo _ 4A and 4_x$ 4x4 4x8 _ _ 4x4 4x8 1.0 25.4 5.7 1.00 5.3/5.231.8/29.9 37.1/35.1 48 768 1536 1.1 27.9 6.3 1.10 57.2/5.230.0/28.1 35.3/33.3 41 656 1312 1.2 30.5 6.8 1.20 28.4 126.6 33.6/31.76 38 608 1216 1.25 31.8 7.1 1.25 5.2/5.2 27.7/25.8 32.9/31.0 35 560 1120 1.3 33.0 7.4 1.30 5.3/5.3 27.0/25.2 32.3/30.4 35 560 1120 1.4 35.6 8.0 1.41 1 5.3/5.2 25.7/23.9 31.0/29.2 32 512 1024 1.5 38.1 8.6 1.51 5.2/5.2 24.5/22.8 29.8/28.0 32 512 1024 1.6 40.6 9.1 1.61 5.2/5.2 23.4/21.7 28.7/27.0 28 448 896 1.7 43.2 9.7 1.71 5.2/5.2 22.4/20.8 27.7/26.0 27 432 864 1.75 44.5 10.0 1.76 5.2/5.2 22.0/20.4 27.2/25.6 27 432 864 1.8 45.7 10.3 1.81 5.2/5.2 21.5/19.9 26.7/25.1 25 400 800 1.9 48.3 10.8 1.91 5.2/5.2 20.7/19.1 25.9/24.3 24 384 768 2.0 1 50.8 1 11.4 2.01 5.2/5.2 19.9/18.4 25.1/23.6 24 384 768 2.1 53.3 12.0 2.11 5.2/5.2 19.2/17.7 24.4/22.9 21 336 672 2.2 55.9 12.6 2.22 5.2/5.2 18.5/17.1 23.7/22.3 20 320 1 640 2.3 58.4 13.2 2.32 5.2/5.2 17.9/16.5 23.1/21.7 20 320 1 640 2.4 61.0 13.8 2.43 5.2/5.2 17.3/16.0 22.5/21.1 19 304 608 2.5 63.5 14.4 2.53 5.2/5.2 16.8/15.4 22.0/20.5 19 304 608 2.6 66.0 15.0 2.64 5.2/5.1 16.3/15.0 21.4/20.1 18 288 576 2.7 68.6 15.6 2.74 5.215.1 15.8/14.5 21.0/19.7 17 272 544 4B 24 2.8 71.1 16.2 2.85 5.2/5.1 15.3/14.1 20.5/19.2 16 256 512 2.9 73.7 16.8 2.96 5.2/5.1 14.9/13.7 20.1/18.8 16 256 512 3.06 1 14.5/13.3 19.7/18.4 16 imijbm 3.1 78.7 18.0 3.17 5.1/5.1 14.1/12.9 19.3/18.1 14 224 448 3.2 81.3 18.6 3.28 5.1/5.1 13.8/12.6 18.9/17.7 14 224 448 3.25 82.6 18.9 3.33 5.1/5.1 13.6/12.4 18.7/17.6 14 224 448 3.3 83.8 19.2 3.39 5.1/5.1 13.4/12.3 18.6/17.4 14 224 448 3.4 86.4 1 19.9 3.50 5.1/5.1 13.1/12.0 18.2/17.1 13 208 416 3.5 88.9 20.5 3.61 5.1/5.1 12.8/11.7 17.9/16.8 13 208 416 3.6 91.4 21.1 3.72 5.1/5.1 12.5/11.4 17.6/16.5 12 192 384 3.7 94.0 21.7 3.82 5.1/5.1 11.2/11.1 17.3/16.3 12 192 384 3.75 95.3 22.0 3.88 5.1/5.1 12.0/11.0 17.2/16.1 12 192 384 3.896.5 22.3 3.94 5.1/5.1 11,9/10.9 17.0/16.0 12 192 384 3.9 99.1 23.0 4.05 5.1/5.1 11.7/10.7 16.8/15.8 12 192 384 4.0 101.6 23.6 4.16 5.1/5.1 11.4/10.4 16.5/15.5 12 192 384 4.1 104.0 24.2 4.26 5.1/5.1 11.2/10.2 16.3/15.3 11 176 352 4.2 107.0 24.9 4.39 1 5.1/5.1 10.9/10.0 16.0/15.1 11 176 352 4.3 109.0 25.5 4.49 5.1/5.1 10.7/9.8 15.B/14.9 11 176 352 4.4 112.0 26.1 4.60 5.1/5.1 10.5/9.6 15.6/14.7 10 160 320 4.5 1 114.0 26.8 4.72 5.1/5.1 10.3/9.4 15.4/14.5 10 160 320 1.The Long-Term Thermal Resistance(LTTR)values were determined in accordance with CAN/IJLC 5770 at 75°F(24°C).The ultimate R-Value of these products Hn8 depend on individual installation circumstances.2.Value represents average results(Grade 2/Grade 31.3.Assumes 48'flatbed truck. Refer to the Safe for Use instructions and product label prior to using this product The Safe for Use instructions are available by calling(800)922-5922 or on the Web at vWVW.jm.cOm/roofing. RS-5137 10-17(Replaces 6-17) Tuered ENHGY 3 Johns Manville Polyisocyanurate Roof Insulation Johns Manville Tapered Polyiso Offerings Please refer rothe previous page for typical physical properties. vwue 1 Pieces Foo. Slope Profiles Thi.k Noinklid I per Unit per Unit per Unit 1/16 int 152 mm/m) 1 1 1/16 0.5 0.75 3.6 70 7120 700 zs" 27s 3.0" B 1/16 0.75 1 5.0 50 800 700 1 1/16 1 1 1.25 6.4 38 608 684 2 1/16 1.25 1.5 7.8 32 512 704 to 9e 3 1/16 1 1.5 1.75 9.3 28 416 676 'A,7e 7 : 3 • z z �' 4 1/16 1.75 2 10.7 22 352 660 AU Pa alsspaoalc eo 5 1/16 2 1 2.25 12.1 20 320 680 6 1116 2.25 1 2.5 13.6 1 18 288 684 1/E int n04 mmlm► AA 1/8 0.5 1 4.364 1024 768 2„ 2_. 30" 35" 4.0" 4.5" i0" 5,1- A E- A 1/8 1 1.5 7.1 38 608 760 M A B 1/8 1.5 2 10.0 26 416 728 zr FEW M A C 1/8 2 2.5 12.9 20 320 720 4A'Fbw D** 1/8 2.5 3 15.9 16 256 704 M A e c o E F ff E" 1/8 3 3.5 18.9 14 224 728 '-xlendea--ndsrec al o•de,Panels 0,E.F FF F*" 1/8 3.5 4 22.1 12 192 720 n1-" '12'" ".7-" 7.25" 775" 3.25' 375" 4.75" 475" FF** 1/8 4 4.5 25.3 10 1 160 680 R 1/8 0.75 1.25 5.7 44 704 704 K s S 1/8 1.25 1.75 8.6 30 480 720 A s r u v w 3rFill. T 1/8 1.75 2.25 11.4 22 352 704 AL--ls Sdeoal order U 1/8 2.25 2.75 14.4 16 256 640 V 1/8 2.75 3.25 1 17.4 14 224 1 672 W 1 1/8 3.25 3.75 1 20.5 12 192 1 672 06 A6t 111"ONm) J 3/16 1 1.75 7.8 32 512 704 0' 175" 25- 3.25' 4.0" 475" 55" 0.5" 1.25' 2.0 2.75' 3.5' 4.25' 5.0' K 3/16 1.75 2.5 12.1 20 320 680 L** 3/16 2.5 3.25 16.6 16 256 736 M*" 3/16 3.25 4 21.2 12 192 696 d K II ' JJ 3/16 0.5 1.25 5.0 52 832 728 J K ► r sr JJ KK u W 3r KK 3/16 1.25 2 9.3 28 448 1 728 All Panels speoarD.de AN Panels SPeoal Olde, LL** 3/16 2 2.75 13.6 18 288 1 691 MM*" 3/16 2.75 3.5 18.2 14 1 224 j 694 1/4 illi t 126.E wpm G 114 1 2 8.6 30 480 720 15' iso" 2 5" 3s- 4 5' S. 5.5- 1 n' 2 9• 30 4a" 5 r e.9" H 1/4 2 3 14.4 16 256 640 r x X 1/4 0.5 1.5 5.7 48 768 768 Y 1/4 1.5 2.5 11.4 24 384 768 x r Z** 1/4 1 2.5 3.5 17.4 16 256 768 Fnended,d See gal ones=a„els z 22 All nein S:-A DO,, ZZ** 1/4 1 3.5 1 4.5 23.6 1 12 1 192 1 768 3/E int 1312 mmlm) oSS I 318 0.5 2 7.1 I 36 576 720 s f /7\ _ ss TT /,� TT*" 3/8 2 3.5 15.9 16 256 704 TT . l3,d 1 I AS Panels S.-al o-de 1/2 inch 141.6 tsglm) G 1/2 0.5 2.5 8.6 1 32 512 768 ].5" 2 4.h" b.b" --` :5' 45" '.3'- 3.0" bA I o GG"" 1/2 2.5 4.5 20.5 12 192 672 s �� i XX 1/2 1 3 j 11.4 22 352 1 704 reg,d�,dsoe„alo,den,�els7C soecal0-e, ,^e^_a^els ear e =__- -_,es-and less labor Tapered Recycle Content: Recycled content is dependent upon average thickness. To calculate, Refer to the Safe for Use Instructions and product label prior to using this product match the average thickness of Tapered ENRGY 3 to the thickness of Flat The Safe for Use Instructions are available by calling(800)922-5922 or on the Web at ENRGY 3.Use the number from Flat ENRGY 3 as your recycled content. wwwdm.com/roofing. RS-5137 10-17(Replaces 6-17) JI'V7johns Manville Sproule 200 Industrial1 • 1 Perlite Pipe f • Block Insulation PRODUCT R • D DATA SHEET Sproule WR-1200 Sproule WR-1200 Is a preformed,high-temperature,non-wicking pipe and block insulation composed of expanded perlite uniformly reinforced with a high strength fiber for use on systems operating up to 1200°F(650°C). It is inorganic, non- combustible and meets or exceeds the physical property requirements of ASTM C610.Sproule WR-1200 is produced with a blue visual color coding dispersed throughout the product to assure it can be identified as Asbestos Free. Integral to Sproule WR-1200 is, X07Xa distinctive formula and process that inhibits corrosion to outside surfaces of pipe and equipment. THE ADVANTAGES Pipe insulation sections shrink-wrapped with poly film for protection from abrasion during shipment Block insulation manufactured with reinforcing scrim to enhance structural integrity. 3 � §ryy^"4 iP ♦♦Nayys.-. Because of its compressive strength,low thermal conductivity and corrosion inhibiting properties, it is a product for =C corroclon Inhlbltor application on high-temperature piping and equipment. ULE WR-1 200 In industrial processing and power generation facilities, • Sproule WR-1200 is the preferred product for stainless steel • ' piping, which is very susceptible to stress corrosion cracking - - at operating temperatures above 140°F (60°C). The XQ feature inhibits corrosion where moisture and chlorides may Pipe Sizes become trapped between insulation and stainless steel. in. mm SprouleWR-1200 Please visit our website at www.jm.com/industrial for specific application information. 1/2-24 15-600 Pipe Insulation- 24-40 600-1000 Quad FIRE SAFETY 30 Min 750 Min Scored orV-Grooved Block Surface Burning Characteristics.When tested in I [12"(305 mm)wide] accordance with ASTM E84,NFPA 255,and UL 723,Sproule Flat Block[6"and 12"wide WR-1200 has flame spread/smoke developed ratings of 0/0. Flat Surfaces (152 mm and 305 mm wide)] Non Combustible.When tested in accordance with ASTM Sproule WR-1200 pipe insulation is 36"(914 mm) in length, and is E136 as defined by NFPA 255 and NFPA 101. available in thicknesses from 1"to 4"(25 mm to 102 mm)in 1/2"(15 mm) increments.Thicker walled materia /rrnnished in double layers. I♦ • i Sproule WR-1200 flat blockinsula 'P�w" "(152mm) and 12"(305 Please visit our website atwww.jm.com/industrial mm)wide]and 36"(914 mm)in Iength,,.0ArTd#&avaiIabIeinthicknesses from 1" to 4" (25 mm to 102 mm) in mm) increments. CUSTOMER SERVICE,TECHNICAL&GENERAL *"Double layered pipe insulation is available for h r line applications INFORMATION(800)866-3234 ` , $_M47 ' Minimum Diameter Insulation Thickness Triple Scored Single Scored l t/2 38 30 762 95 2413 2 51 40 1016 125 3175 2'% 64 50 1270 155 3937 3 76 60 1514 190 4826 3' 89 70 1 1778 1 220 1 5588 4 102 250 6350 SAF Perimeter Systems Toll Free: 800-334-9823 Perimeter Systems 8370 E. Highway 78 Fax: (770)942-4173 fl <<�atire Alun;i;<<nu Arclt;ttcturVilla Rica, GA 30180 www.saf.com SUBMITTAL / DATA SHEET Industrial Series Commercial Gutter System G2-R6 color to match metal roof panels typ. O - --- - ; - ---- O O I�rilO 3" 6" 5" 2" I LQ Legend: A: Heavy Duty Support Brackets @ 30"Centers.(Optional) D: #10 x 2"S.S.Wood Screws B: Heavy Duty Interior Straps @ 30"centers. E: 1-1/2"Stainless Nails or#10 x 1 1/2"S.S.Wood Screws C: Gutter Profile 10'length, 1"telescoping joints. F: Aluminum Rivet to Secure Interior Strap to Gutter. Material Options Finish Options Component Options Metal Gutter Bracket Finish Gutter Bracket Feature Yes No Aluminum EZ Mix Kynar ® ® Support Bracket ® ❑ 0.040 ® Custom Kynar ❑ ❑ Rear Upper Flange ❑ 0.050 ❑ Anodized ❑ ❑ Custom Size ❑ 0.063 ❑ Mill Finish ❑ ❑ 0.080 ❑ ❑ 0.090 ❑ ❑ 0.125 ® Industrial Series Commercial Gutter System:Available in 6", 8", 9"and 12"sizes with 0.1875 ❑ custom sizes available. These commercial gutter systems are based on a heavy duty support 0.250 ❑ bracket and interior strap assembly.The gutter sections are manufactured in 10'lengths Copper pre-notched and punched to receive fasteners. Gutter sections are tapered for a telescoping 16 oz ❑ 1"lap joint that is field drilled, sealed and riveted. Gutter Hardware Package includes joint 20 oz ❑ sealants, stainless screws, and aluminum rivets (unpainted). 32 oz ❑ ❑ (Other Materials are Available upon Request) Default Selection are BOLD) Customer: Project: Address: Location: Phone / Fax: Architect: Johns Manville • • 2001 1 THERMALIndustrial Insulation Group Perlite Pipe& Block Insulation • Mean Te p.r&Wu (•C1 80 psi (550 kPa)to 18 93 204 315 416 538 ASTM C165 Compressive Strength Produce 1 a9 0.140 5076 Compression as 0.120 ASTM C203 Flexural Strength 50-60 psi(345-415 kPa) 0.100 13 lbs.per cu.ft.(210 0.5 - -- -- - 0.080 ASTM C302 Average Density kgs./m') - - 04 ___- - __—- — -__— 0.060 3 Less than 2%After 0.3 24-H ur m oz ASTM C518(Flat) 0.040 ASTM C356 Linear Shrinkage Soaking Period at 01 —asTn+ca3s(atpet o.0.0201200°F(650°C) _ _ o _. ASTM C442 0 zoo 4010 600 Soo woo Maximum Service Temperature 1200°F(650°C) Mau�T�mpMiWre 1'Ft ASTM C610 Material Specification Passes ASTM C665 4orrosivity to Steel Passes W111r.,N W4.11=11111111:11 YAM • ASTM C795/C871/C692 Corrosion: passes 412 .481 .548 .611 .671 728 .782 Austenitic Stainless Steel .059 .069 .079 .088 .097 105 .113 ASTM C1338 Fungi Resistant Passes i .M- 938 916 .515 .557 .601 646 .694 ASTM C1617 Corrosivity to Steel Passes .063 .069 .074 .080 .087 o93 loo ASTM E84 Flame Spread-0 Surface Burning Characteristics Smoke Developed-0 *Sproule WR-1200 Insulation is tested in accordance with ASTM E136 Non-Combustible Passes ASTM C518 and ASTM C335. NRC Reg.Guide 1.36 Passes R-Value @ 75°F 2.2 per inch of thickness QUALITY STATEMENT `xAst � When ordering material to comply with any government specification or any other listed specification,a statement of Industrial Insulation Group products are designed, that fact must appear on the purchase order. Government manufactured and tested to strict quality standards in regulations and other listed specifications require specific our own facilities.This along with third party auditing lot testing,and prohibit the certification of compliance after Is your assurance that this product delivers consistent shipment has been made.There may be additional charges high quality. associated with specification compliance testing.Please refer to IND-CSP-3 for Certification Procedures and Charges. Call customer service for more information. ®� Industrial Insulation Group,LLC manufactures MinWool-1200'mineral fiber pipe,block and a variety of other insulati s mo-12' Gold Calcium Silicate pipe and block insulation;Microporous Blanket Insulation;Super Firetemp` fireproofing board;Spr R-1200"' Perlite pipe and block insulation; high-temperature adhesives, and insulating finishing cement.The physical and chemica pkit . presented herein represent typical, average values obtained in accordance with accepted test methods and are subject t manufacturing variations.They are supplied as a technical service and are subject to change without notice.Numerical flame and smoke developed ratings are not intended to reflect hazards presented by these or any other materials under actual fire Con Check with the Customer Service Office to assure current information. All Industrial Insulation Group products are sold subjec Johns Manville Limited Warranty and Limitation of Remedy.For a copy of the Johns Manville Limited Warranty and Limitation of Remedy, email info.industrial@jm.com. CUSTOMER SERVICE ,Johns Manville TECHNICAL & GENERAL INFORMATION Ju Industrial Insulation Group (800) 866-32 34 2100 LINE STREET•BRUNSWICK,GA 31520 �zAIS Industrial Insulation Group,LC_Printed in USA_ We 2 C Oa'5 wep'­_11%_�" JIVI PVC AND JIVI TPO RHINOPLATE'SYSTIM Johns Manville A 1INSTALIATION GUIDE Insulation Attachment Bond the Membrane Insulation must be fastened to the roof deck in JM PVC or JM TPO •Perform calibration and set up as detailed by the induction RhinoPlate roof systems per the appropriate fastening pattern welder's owner's manual.Refer to the induction welder's owner's details,depending on membrane type and uplift requirements. manual for calibration and welding. For specific requirements,contact the JM Technical Services -Adjust the handle height,if desired,by releasing handle clamps team at(800)922-5922.NOTE:JM PVC RhinoPlates must be and pulling or pushing handle to desired position. used in JM PVC systems and JM TPO RhinoPlates must be used in JM TPO systems;JM TPO and JM PVC RhinoPlates are not •Center the induction welder over the first plate in the pattern interchangeable. and activate the weld.WARNING:The induction welder must be centered over the plate to create a 100%bond.If an error occurs Always cut insulation to fit closely around all roof penetrations. during activation,refer to the induction welder owner's manual for Around drains,taper insulation a minimum of 36"x 36"(91.44 cm corrective action. x 91.44 cm)to ensure proper drainage.Apply rigid insulation directly over fluted steel decks to provide smooth,continuous •Immediately place a cooling clamp over the welded plate. membrane support.Insulation should be installed with long edges WARNING:Keep clamp in place for at least 45 seconds while the perpendicular to the direction of the deck and supported by the assembly cools. deck flange.Do not allow the edge of either board to overlap on an •Repeat this process for each plate. open flute when butting insulation layers.Cut the insulation so the edge of the board is at the center of,and supported by,the flange. NOTE:To increase the pace,work across the sheet,moving cooling clamps from one row to the next as needed.It is best to work in the NOTE:Do not overdrive the plate and fasteners,as this will lead to direction of the aligned rows. poor bonding adhesion to the membrane when applied. NOTE:To eliminate damage to the membrane,keep the magnets NOTE:Take caution to ensure there is no moisture on the board or and surface of membrane clean and free from debris or membrane prior to application.Any water or dew will decrease the contamination both prior and during the induction welding process. bonded welding circumference. Always wipe the magnet clean when moving to the next plate. Installing Membranes When removing the magnet do not twist it off,as it may damage the membrane. Unroll the JM PVC or JM TPO Membrane and position without stretching.Allow the membrane to relax at least 15 minutes when NOTE:To determine if a weld has been made,place the plunger the temperature is above 60°F(16°C),or 30 minutes when the next to a welded plate and create enough suction to lift the membrane.If welded,you will see a complete round outline of the temperature is below 60°F(16°C),prior to installation.Install all roof deck materials(vapor retarders and insulation)in complete plate.If the assembly is not welded,the membrane will lift up from sections,and cover with the membrane immediately to produce the plate.Mark any plates that are not welded as a reminder to weather-tight sections each day.Phased construction is not complete the weld. permitted. NOTE:RhinoPlates are only approved for PVC and TPO membranes that are 60 mil thick and greater. Safety Guidelines:Induction welding requires special safety precautions prior to,during and after installation.When working with welding equipment,contractors must use extra care and extreme caution to prevent acOftnts.Carelessness can lead to loss of life,injury and loss of p Yn �n LO^ N� RS-8849 3-14(Replaces 8-13) JAI PVC DETAIL MEMBBANE Johns Manville Features and Components C-po m Use: To easily form flashings around corners and penetrations. A Specifically designed for use in areas that cannot be Also" properly detailed with PVC field membrane. s'"gle%+' Material: 75 mil(1.91 mm)thick,reversible,flexible,non-reinforced, Type UV-resistant PVC(polyvinyl chloride)with Elvaloy"KEEFW (ketone ethylene ester). Rash�wali Colors: White/Grey Grey ES/White rbrorrei Sandstone/White Sandstone ES/White ��� White/Charcoal 'Elvaloy is a registered trademark of E.I.du Pont de Nemours and Company or its affiliates. System Compatl 11 l l lty This product may be used as a component in the following systems.Please reference product application for specific installation methods and information. a ®�:r °f Do not use in Multi-Ply systems Si Compatible with the selected Single Ply systems above Key: HA = Hot Applied CA= Cold Applied HW= Heat Weldable SA= Self Adhered MF= Mechanically Fastened FA = Fully Adhered BA= Ballasted Peak Advantages Guarantee Information Installation/Application Systems Approved for use in any JM Peak Advantage Guarantee System Hot Air Weld • Do not install JM PVC Detail Membrane in direct contact with asphalt or coal tar pitch • Refer to JM PVC applicator guides or detail drawings for instructions Packaging and Dimensions Roll Size 36'x 50'(91.44 cm x 1524 m) Nominal Thickness 0.075"(1.91 mm) Coverage per Roll 150 ft'03.94 mz)(gross) Weight per Roll 75 Ib(34.0 kg) Storage Storage Conditions Store indoors,o f sunlight,in a cool, dry location prior to . C0 Refer to the Safety Data Sheet and product label prior to using this product. The Safety Data Sheet is available by calling(800)922-5922 or on the Web at www.jm.com/roofing. RS-6311 11-16(Replaces 1-15) I q A/7" JAI PVC NOWT PATCH Johns Manville Features and Components Component Use: To seal seam laps where perimeter and/or header �nAj sheets intersect(T-Joint)in PVC systems. Single Ply Material: Flexible,non-reinforced,UV-resistant PVC(polyvinyl TYR chloride)with Elvaloy*KEE(ketone ethylene ester). m'$ MS Colors: White;Grey;and Sandstone M� g Elvaloy is a registered trademark of E.I.du Pont de Nemours and Company or its affiliates. System Compatibility This product maybe used as a component in the following systems.Please reference product application for specific installation methods and information. r1i. Do not use in Multi-Ply systems 63 Compatible with the selected Single Ply systems above Key: HA = Hot Applied CA = Cold Applied HW = Heat Weldable SA = Self Adhered MF = Mechanically Fastened AD = Adhered BA = Ballasted Peak Advantage® Guarantee Information Installation/Application Systems Approved for use in any JM Peak Advantage Guarantee System Hot Air Weld Refer to JM PVC applicator guides or detail drawings for instructions. Packaging and Dimensions Size(diameter) 4.5"01.4 cm) Patches per Box 100 Weight per Box 6.4 Ib(2.9 kg) Thickness 0.060"11.52 mm) Storage Storage Conditions Store i out of direct sunlight,and keep clean a rto application. OA,I Refer to the Safety Data Sheet and product label prior to using this product. The Safety Data Sheet is available by calling (800)922-5922 or on the Web at www.im.com/roofing. RS-8319 4-18(Replaces 10-14) JM PVC PIPE BOOTS Johns Manville Features and Components Conwn" Use: A smooth, cone-shaped boot for traditional orsplit-pipe A PAccessory flashing applications to securely seal the penetration. Single Ply Pipe boots eliminate the need for field fabrication. Y TWe Material: Flexible,non-reinforced,UV-resistant PVC(polyvinyl Cp chloride)with Elvaloy°*KEE(ketone ethylene ester). rr Penetration Colors: White;Grey;and Sandstone *Elvaloy is a registered trademark of E.I.du Pont de Nemours and Company or its affiliates. System Compatibility This product maybe used as a component in the following systems.Please reference product application for specific installation methods and information. m ral Do not use in Multi-Ply systems y Compatible with the selected Single Ply systems above Key: HA = Hot Applied CA = Cold Applied HW = Heat Weldable SA = Self Adhered MF = Mechanically Fastened AD = Adhered BA = Ballasted Peak Advantage®Guarantee Information Installation/Application Systems Approved for use in any JM Peak Advantage Guarantee System Hot Air Weld • Do not install JM PVC Pipe Boot in direct contact with asphalt or coal tar pitch • Each boot has a cutting guide for easy reference and diameter measurements.JM PVC Pipe Boots accommodate pipe sizes from 1"to 6"(2.5 cm to 15.2 cm)in diameter.Standard size pipe clamps covering the largest possible range(6"diameter)are included for each pipe boot.Dimensions less than 1.5"diameter may require alternative clamps.Standard pipe boots are heat welded to JM PVC Membrane. • Refer to JM PVC appliceog or detail drawings for instructions Packaging and Dimensions Size* ^6"(2.5 cm-15.2 cm) Boots per Box 1 . rings included) Weight per Boot kg) Weight per Box 12 (5.44 kg) Thickness 1 0.060"(1.52 mm) *Standard size pipe clamps covering the largest possible range(6"diameter)are included for each pipe boot. Dimensions less than 1.5'(3.8 cm)diameter may require alternative clamps. Storage Storage Conditions Store indoors,out of direct sunlight,and keep clean and dry priorto application. Temperature Range I 60°F and 80°F(16°C and 27°C) Refer to the Safety Data Sheet and product label prior to using this product. The Safety Data Sheet is available by calling(800)922-5922 or on the Web at www.jm.com/roofing. RS-8318 4-18(Replaces 10-14) JIB PVC MEMBRANE ADHESIVE Johns Manville AA,. (Low VOQ Features and Components , __!�!�`—� � Cw"ent Use: For adhering JM PVC membranes to approved substrates. Do not use on fleece-backed membranes. Type: One-part,synthetic polymer-based membrane adhesive. TTM Substrates:Compatible with approved insulations and cover boards, Membrane wood substrates,concrete,and light-weight concrete decks. Single Color: Amber System Compatibility This product maybe used as a component in the following systems.Please reference product application for specific installation methods and information. till- 2 Do not use in Multi-Ply systems e1 Used to adhere Membranes in PVC Single Ply systems Key: HA= Hot Applied CA = Cold Applied HW= Heat Weldable SA= Self Adhered MF= Mechanically Fastened FA = Fully Adhered BA= Ballasted Energy and the Environment Installation/Application VOC 7 199.4 g/I(EPA Method 24) This product maybe used in jurisdictions limiting VOC(volatile organic compounds)content of single ply roofing adhesive to no greater than 250 g/l. Long Nap Roller Physical Properties • Apply when the ambient and substrate temperature is 40°F(5°C) JIM PVC Membrane and rising. Property (LowWeight per Unit 7.081b/gal(0.85 kg/I) • Refer to the application instructions guidelines for proper utilization of this adhesive. Viscosity 1,800-2,400 cps Specific Gravity 0.849 Packaging and Coverage Container Size 5 gal(18.91)pail Precautions Shipping Weight(approx.) 37 lb(17.0 kg) Pails per Pallet 45 7hisproductis flammable.Do not use forsplicing.Do not apply adhesive near Pallet Weight 1,8371b(833.3kg) seams or splices where a hot-air welder will be used.Adhesive contains ingredients which could be harmful if mishandled.Contact with skin and eyes Pallets per Truck 22 should be avoided,and the recommended personal protective equipment Coverage Rate*(two sided) o 90 ftZ/gal(1.23 mz to 2.03 m2/I) should be worn, •Coverage,open and dry time rates can vary dram tic nding on the particular substrate and environmental conditions.Coverage rates state pproximate only. If FM Globale or UL•approval is required,consuftspecific ay�orthe UL Certifications Directory for specific application rates. GO Storage Shelf Life 12 months from manufacture dateOK Storage Conditions Clean,dry,indoor environment in an unopened container Temperature Range 60°F-80°F(16oC-27°C)-Protect from freezing Exposure Window Johns Manville recommends immediate and complete use upon opening.Use open containers within 48 hours of opening.Replace lid on can when not in use.Adhesive that has changed color or Refer to the Safety Data Sheet and product label prior to using this product. viscosity is no longer usable. The Safety Data Sheet is available by calling(800)922-5922 or on the Web at www.jm.com/roofing. RS-8323 10-14(Replaces 8-13) • JM PVC MIMBHANI ADHISIVI Johns Manville (Water Based) Features and Components corms Use: For adhering JM PVC membranes to approved substrates. AD Limited availability from October 1st to April 15th. See Bulletin T15-007,dated September 18,2015 for additional information. TM Type: One-part,water based membrane adhesive. M Membane Substrates:Compatible with approved insulations and cover boards, �+ _ Single concrete,and light-weight concrete decks. - Color: White System Compatibility This product maybe used as a component in the following systems.Please reference product application for specific installation methods and information. CL Do not use in Multi-Ply systems co Used to adhere Membranes in the selected PVC Single Ply system above Key: HA= Hot Applied CA= Cold Applied HW= Heat Weldable SA = Self Adhered MF= Mechanically Fastened FA = Fully Adhered BA= Ballasted Energy and the Environment Installation/Application VOC 1 179.0 g/L(EPA Method 24) This product maybe used in jurisdictions limiting VOC(volatile organic compounds)content of In single ply roofing adhesive to no greater than 250 gll. Med.Nap Roller Physical Properties • Applywhen ambient and substrate temperature is 50°F(10°C)and rising. JM PVC Membrane Adhesive • This is for both 1-and 2-sided application.In Fleece-backed application Property r systems,adhesive should be applied to substrate only. Weight per Unit 8.99lb/gal(1.08 kg/I) • For 2-sided applications(smooth backmembrane),t/2 the adhesive is placed Viscosity 10,000-16,000 cps on the back side of the membrane,and the balance on the substrate. Specific Gravity 1.078 • Coverage rate for both 1-and 2-sided will be the same when installed. • Refer to the application instructions guidelines for proper utilization of this adhesive. Precautions Packaging and Coverage Adhesive contains ingrediemMich couldbehafmfulifmishandled. Container Size 5 gal(18.9 1)pail Contactwfdlskin andeyesshouldbeavoided,andtherecommended Shipping Weight(approx.) 46lb(20.9kg) personal protective equipmentshou/d be wom. Pails per Pallet 45 Pallet Weight 2,138 Ib(969.8 kg) Pallets per Truck 20 Coverage Rate*(I&1-sided) 90ftz— (203 m2-3.19m2/I) Coverage,open and dry time rates can vary dramatically depen in articular substrate and environmental conditions.Coverage rates stated herein area x ly. If FM Global`or UL''approval is required,consult specific RoofNays.or e L6.4n ycations Directoryfor specific application rates. 7 Storage Shelf Life 12 months from manufacture date Storage Conditions Clean,dry,indoor environment in an unopened container Temperature Range 60°F-80'F(16°C—27°C)-Protect from freezing Exposure Window Johns Manville recommends immediate and complete use upon opening. Use open containers within 48 hours of opening.Replace lid on can when Refer to the Safety Data Sheet and product label prior to using this product. not in use.Adhesive that has changed color or viscosity is no longer usable. The Safety Data Sheet is available by calling(800)922-5922 or on the Web at www.jm.com/roofing. RS-8324 10-18(Replaces 9-1$) tmjTj 7 JM SINGIE P1Y MIMBRANE REANER (Low VO Q Johns Manville Features and Components c«' Use: To remove dirt,asphalt or other contaminants from JM TPOCnL and PVC single ply membranes to ensure a good weld or bond.Can be used prior to applying TPO Membrane Primer %to` Type for peel and stick applications. M Type: One-part,low VOC solvent,membrane cleaning 9 embrane agent. M Single Ply Color: Clear - System Compatibility This product maybe used as a component in the following systems.Please reference product application for specific installation methods and information. a Do not use in Multi-Ply systems Used to dean Membranes in the selected Single Ply systems above Key: HA= Hot Applied CA= Cold Applied HW= Heat Weldable SA= Seff Adhered MF= Mechanically Fastened FA = Fully Adhered BA= Ballasted Energy and the Environment Installation/Application Maximum VOC I <20 g/I �— This product may be used in jurisdictions limiting VOC(volatile organic compounds)content d single ply roofing adhesive to no greaterthan 250 gA. Physical Properties Na Clothber ScubberPad JM Single Ply Membrane Cleaneg Refer to the application instructions guidelines for proper utilization Property (Low VOC) E of this cleaner. Weight per Unit(approx.) 7.5lb/gal(0.90 kg/I) Packaging and Coverage Viscosity 0.32 mPa Specific Gravity 0.790 Container Sizes 1 al Box of 4 ails 5 gal(18.91)pail Precautions Shipping Weight(approx.) 32 Ib(14.5 kg) 48 Ib(21.8 kg) Containers per Pallet 36 36 Johns Manville Single PlyMembranerCleaner(LowVOC)isacombustible Pallet Weight 1,202 lb(545.2 kg) 1,387 lb(629.1 kg) material and should be shipped and stored away from open flames,heat or Pallets per Truck 26 22 sourcesofignition.Keepall padstighdysea led while instorage.Itsh0uldbe Coverage Rate-(approx.) 400ft2/ga1(9.82m1/1) used onlyin well-ventilated areas.Itmaycause eye,skin and respiratory Coverage,open and drytime rates can vary dramatically depending on the particular substrate irritation,and isharmfu/orfatal ifswallowed.Avoid contactwidf skin.Use and environmental conditions.Coverage ratesstated herein are approximate only. impervious clothing and rubberg/oves to avoid prolonged or repeated If FM Globale or UL®approval is required,consult spec RoofNav'm orthe UL Certifications contact with skin.Read the container label and follow all safety instructions. Directory for specific application rates. Storage /C Shelf Life 9 months from manufacture Storage Conditions Clean,dry,indoor environment,A i unlight, in an unopened container Temperature Range 60°F–80°F(1 VC–27°C)-Protect from fr ez1 Exposure Window Johns Manville recommends using open containers within designated shelf life.Replace lid on can when not in use. Refer to the Safety Data Sheet and product label prior to using this product. The Safety Data Sheet is available by calling (800)922-5922 or on the Web at www.jm.com/roofing. RS-8400 5-15(Replaces 4-15) flat'�I"17 � EN G GY 3° Polyisocya n u rate Roof Insulation Johns Manville Meets the requirements of ASTM C 1289,Type 11, Class 1, Componem Grade 2(20 psi) I •ENRGY 3/Tapered ENRGY 3 Flat Insulation Grade 3(25 psi) •ENRGY 3 25 PSI/Tapered ENRGY 3 25 PSI ��+�� '==rL% '= Mum-ptv Single PFy Features and Components Type Glass-Reinforced Facers: Provides rigidity and resistance to ftT FIT indentation and crushing,and are compatible with BUR,modified High Thearal Glass-Reinforced bitumen and single ply membrane systems. Facers TP Closed Cell Polyisocya n u rate Foam Core:Provides high R-value per � � Tapered ?s S��- S� inch in built-up,modified bitumen,metal roof and single ply roof systems,and approved for direct application to steel decks. Tapered Closed Cell Polyisocyanu rate Foam Core System Compatibility This product maybe used as a component in the following systems.Please reference product application for specific installation methods and information. BUR APP SBS mmm mm71F TPO PVC I EPDM SAm0m0mmIA Compatible with the selected Multi-Ply systems above Compatible with all Single Ply systems Key: HA= Hot Applied CA = Cold Applied HW= Heat Weldable SA = Self Adhered MF= Mechanically Fastened FA = Fully Adhered BA = Ballasted Energy and the Environment Installation/Application LEED® Recycled Content Varies with thickness,see Product Data WA, and Packaging table on next page. � , U , Produced with a pentane blowing agent with zero ozone depletion and virtually no global warming potential. WA and HotAsphaR Urethane Mechanically Loose Laid Adhesive Fastened Peak Advantage®Guarantee Information Refer to the application instructions guidelines for proper utilization Systems of this product. For use in approved JM Peak Advantage Roofing Guarantees Flute Span: Width of Rib Opening: Up to 25/8" Up to 3%" Up to 4%" (6.67 cm) (8.57 cm) (11.11 cm) Codes and Approvals Insulation Thickness/mint 1.0"(2.54 cm) 1.2"(3.05 cm) 1.3"(3.30 cm) ��,SSIFyeo U <�> MIAMVMDECOVMY Pj Packaging and Dimensions uali4.J ark" COU$ Mie C,,t,el App a Ce,niied IIiF.nlee APPROVED Product Control Approved Flat Sizes' 4'x 8 (1.22mx (1.22 m x 2.44 m) • FMS Standards 4450/4470 Approvals(refer to FM RoofNav') Tapered Sizez • UL'O Standard 790,263 and 1256(refer to UL Roofing Materials O.AwAT,22 m) system directory) Producing Locations Bremen,IN Cornw I, Fernley,NV • Meets the requirements of CAN/ULC S704,Type 2&3,Class 3Hazleton,PA Jacksonvl L • California Code of Regulations,Title 24,Insulation Quality Stocking Locations' Grand Prairie,TX Southgate, cy,CA 1.For available thicknesses,see Product Data and Packaging table on page fof this data Standard License#TI-1341 sheet Other sizes available by special request,some sizes are not stocked and special •Third-parry certification with the PIMA Quality Mark'"for order with minimum order quantities.Contact your JM Sales Representative for details. Lon Term Thermal Resistance ILTTR)values 2.Tapered ENRGY 3 and Tapered ENRGY 3 25 PSI are available in thicknesses of 12"to 4". Long-Term Available profiles are shown on page 3 of this data sheet In some regions extended panels are also available. Refer to the Safe for Use instructions and product label prior to using this product 3.Not all sizes,thicknesses,and products are stocked at all locations,please call Customer The Safe for Use instructions are available by calling(800)922-5922 or on the Web at Service at 1-877-766-3295. www.im.com/roofing. Note:Technical information on this data sheet is intended to be used as a general guideline only and is subject to change without notice. Contact your JM Sales Representative for further details. RS-5137 10-17(Replaces 6-17) Tapered INHGY 3"' Polyisocyanurate Roof Insulation Johns Manville Johns Manville Tapered Polyiso Offerings Please refer to the previous page for typical physical properties. ® Sloper 1116 inpt 152 mm/m) 1A 1/16 0.5 0.75 3.6 70 1120 700 0.5- 0.75- 1.0" 1.25" 1.5" 1.75' 2.0" 2.25" 2.5" 2.75" 3.0" 1B 1/16 0.75 1 5.0 50 800 700 1 1/16 1 1.25 6.4 38 608 684 2 1/16 1.25 1.5 7.8 32 512 704 IA Ie 3 1/16 1.5 1.75 9.3 28 416 676 1A 18 1 2 3 4 5 6 2.0-Filler 4 1/16 1.75 2 10.7 22 1 352 660 All Panels Special Order 5 1/16 2 2.25 12.1 20 320 680 6 1/16 2.25 2.5 13.6 1 18 1 288 1684 1/8 int 110.4 mm/m) AA 1/8 0.5 1 4.3 64 1024 768 0.5" 1.0" 1.5" 2.0' 2.5- 3.0- 3.5' 4.0" 4.5" 5.0" 5.5' A 1/8 1 1.5 7.1 38 608 760 A B 1/8 1.5 2 10.0 26 416 728 2.0"Filler as A C 1/8 2 2.5 12.9 20 320 720 4.0"Eller D** 1/8 2.5 3 15.9 16 256 704 ^^ A e c 7E F FF E** 1/8 3 3.5 18.9 14 224 728 Extended andSpecial Order Panels:O,E,F,FF F** 1/8 3.5 4 22.1 12 192 720 0.75- 1.25- 1.75" 2.25" 2.75- 3.25' 3.75" 4.25- 4.75" FF** 1/8 4 4.5 25.3 10 160 680 R 1/8 0.75 1.25 5.7 44 704 704 It s S 1/8 1.25 1.75 8.6 30 480 720 K s T u v w 3.0-Filler T 1/8 1.75 2.25 11.4 22 352 704 All Panels Special Order U 1/8 2.25 2.75 14.4 16 256 640 V 1/8 2.75 3.25 17.4 14 224 1 672 W 1/8 3.25 3.75 20.5 1 12 1 192 672 3/16 int(15.6 mm/m) J 3/16 1 1.75 7.8 32 512 704 1.0" 1.75" 2.5" 3.25" 4.0" 4.75- 5.5- 0.5" 1.25" 2.0' 2.75' 3.5" 4.25" 5.0" K 3/16 1.75 2.5 12.1 20 320 680 L** 3/16 2.5 3.25 16.6 16 256 736 M** 3/16 3.25 4 21.2 12 192 696 J K JJ KK 11 3/16 0.5 1.25 5.0 52 832 728 J K L M 10'Filler JJ KK LL MM 3.0-Filler KK 3/16 1.25 2 9.3 28 448 728 All Panels Special Order All Panels Special Order LL** 3/16 2 2.75 13.6 18 288 691 MM** 3/16 2.75 3.5 1 18.2 14 224 694 1/4 int(20.6 mm/m) G 1/4 1 2 8.6 30 480 720 05' 1.50' 2.5" 3.5" 4.5" 5.5- 6.5" 1.0" 2.0" 3.0- 4.0' 5.0" 6.0' H 1/4 2 3 14.4 16 256 640 1** 1/4 3 4 20.5 12 192 672 x r 2.0"Filler X 1/4 0.5 1.5 5.7 48 768 768 X Y 0 H Y 1/4 1.5 2.5 11.4 24 384 768 X Y 7 a 4.0"Filler a a I 3.0-Filler Z** 1/4 2.5 3.5 17.4 16 256 768 Extended and Special Order Panels:2,71 All Panels Special Order ZZ** 1/4 3.5 4.5 23.6 12 192 768 3/8 int 1312 mm/m) 0.5" 2.0" 3.5" 5.0" 6.5" SS 3/8 0.5 2 7.1 36 576 720 / 35 TT I SS Ti 3.0"Filler ^" TT** 3/8 2 3.5 15.9 16 256 704 AM Panels Special Ord., ` 1/2 int 141.6 mm/m) Q 1/2 0.5 2.5 8.6 32 512 768 0.5- 2.5" 4.5" 6.5" 0.5" 2.5" 4.5" 1.0" 3.6- 5.0" QQ** 1/2 2.5 4.5 20.5 12 192 672 ° ° n as Fill a za- L zo- XX 1/2 1 3 11.4 22 352 704 Extended and Special Order Panels:GO Special order (heft'•°F/Btu) "Extended panels require less adhesive and less labor. Tapered Recycle Content: Recycled content is dependent upon average thickness. To calculate, Refer to the Safe for Use instructions and product label prior to using this product match the average thickness of Tapered ENRGY 3 to the thickness of Flat The Safe for Use instructions are available by calling(800)922-5922 or on the Web at ENRGY 3.Use the number from Flat ENRGY 3 as your recycled content. wvvw.jm.com/roofing. RS-5137 10-17(Replaces 6-17) BOARD LAYOUT PARAPET WALL PERIMETER I BUILDING P WIDTH(x) I HEIGHT A (SEE NOTE 4 or 5) < 60 FT R.:. A COR NER PERIMETER E l " T REFER t 'COR JEA DEFINITION" W. A L BUILDING HEIGHT > 60 FT PERM ETER FIELD CORNER DEFINITION (SEE NOTES 4, 5&6) ... ... . ... ........ .... . ... ............. . . . lull .......... ........ .... .... ............... .. ..... ................ ....... . ........ . .... ..................... ..... .. . ........ . .. .. PERIMETER WIDTH(X) VNO PARTIAL FASTENING DECKING (SEE NOTE 4 or 5) (SEE NOTE 7) CUT-AWAY FASTENING PATTERNS for 4'x W INSULATION BOARDS 12" 36" 36" 12" 12" 18" 18" 18" 18" 12" 12" 18" 18" 18" 18" 12" p JM PVC RHINOPLATES v .... .... a ® ' • N AND SCREWS(TYP.) .. W ..... .. . o •.. :: :.�. .: :� FIELD PERIMETER CORNER 6 FASTENERS/BOARD 10 FASTENERS/BOARD 15 FASTENERS/BOARD UPLIFT NOTES GENERAL NOTES 1. CALCULATE UPLIFT DESIGN PRESSURES IN ACCORDANCE WITH ASCE-7. JM PVC MEMBRANE IS HEAT WELDED TO JM PVC RHINOPLATES 2. FASTENING DIAGRAM IS BASED ON FM GLOBAL DATA SHEET 1-29. USING THE RHINOBOND TOOL. THIS MEMBRANE FASTENING PATTERN ACHIEVES AN FM 1-90 UPLIFT RATING OVER AN FM APPROVED DECK. ALL FASTENERS MUST PENETRATE HIGH RIB OF DECK. 3. INSTALL INSULATION WITH LONG JOINTS AND END JOINTS IN A CONTINUOUS STRAIGHT LINE IN ORDER TO CREATE A LINEAR FASTENING PATTERN. ^� MULTIPLE LAYERS OF INSULATION ARE TO BE STAGGERED. e—t, �, ►1 C, �(-, O . U L___ 4. ROOF HEIGHT<_60 FT,THE PERIMETER(X)IS THE SMALLER DIMENSION OF: 10%OF THE SHORTEST SIDE(PLAN VIEW) OR 40%OF THE ROOF HEIGHT, BUT ONOT LESS THAN 4%OF THE SHORTEST SIDE (PLAN VIEW)OR 4 FEET. A� 5. ROOF HEIGHT>60 FT,THE PERIMETER(X)IS: //� 10%OF THE SHORTEST SIDE(PLAN VIEW)BUT NOT LESS THAN 4 FEET. `(+� 6. THE CORNERS MAY BE TREATED AS PERIMETERS IF THE PARAPET IS OA ENHANCE GREATER THAN OR EQUAL TO 3 FT ON ALL SIDES ACCORDING TO ASCE-7. 7. IF ANY PORTION OF THE BOARD LIES IN A PERIMETER OR CORNER ZONE, ENHANCE THE FASTENING OF ENTIRE BOARD. JM PVC RHINOPLATE FASTENING SYSTEM (6-10-15) DRAWING NO. SCALE ISSUE DATE REV.NO. Johns Manville is a Manufacturer of commercial roofing products and offers this general conceptual N.T.S 2-12 1$ information to you as a courtesy.This complimentary assistance is not to be used or relied upon by PRH 6,10,15 anyone a substitute for professional engineering design and documentation required building b"7 � CAD FILE: code,contract, ract,or applicable law. By accepting these comments you agree they do not constitute any representations,endorsements of,or an assumption by Johns Manville of any liability for either Johns Man vi//e BOARD FASTENING PVC RHINO 6-10-15.dwg the adequacy of the design of this building or any other material not supplied by Johns Manville. I m HSC000oard "17 Perlite-Based Cover Board Meets the requirements of ASTM C 728,Type 1 Toploc'CCoatingcemponerr Features and Components TopLoc®Coating:Top surface is sealed with this special coating cover Board to reduce excessive asphalt absorption in hot-asphalt applied Moro-Ply roofing systems. Type Expanded Perlite: Provides good dimensional stability,excellent PL insulation value with stable R-value and fire resistance. Perlite Low Thermal Insulation Board:Composed of expanded perlite, 4111 LT reinforcing cellulosic fibers and selected binders. Lav Thermal Reinforcing Cellulosic Fibers: Consists of recycled newsprint to 0 provide strength to the board as well as high recycled content. • Expanded Perlite • Reinforcing JM utilizes third party certification by ULI Environment to certify Cellulosic Fibers the recycled content and contributes to the LEED Materials and • Selected Binders Resource(MR) credit 4. Hot Asphalt Friendly: Protective cover board or low thermal insulation board proven to reduce the tendency for blistering in hot IP asphalt applications. System Compatibility This product maybe used as a component in the following systems.Please reference product application for specific installation methods and information. �m m Compatible with the selected Multi-Ply systems above v+ Do not use with Single Ply systems Key: HA = Hot Applied CA = Cold Applied HW = Heat Weldable SA = Self Adhered MF = Mechanically Fastened AD = Adhered BA = Ballasted Energy and the Environment Installation/Application 32%average LEEDO Recycled Content For post and pre-consumer recycled content percentages, visit the Fesco Board product page on the JM roofing Web site.EN IRONMENTAL bi k]__ 0 ,ENRGY 3^25 Psi Insulation Hot Asphalt Cold Applied Urethane Mechanically UL CLAN Boardcontains an average Adhesive Fastened L& ' ' of 34%recycled content. Referto the Application Guides and Detail Drawings for instructions. Peak Advantages Guarantee Information Packaging and Dimensions Systems Guarantee Term* Size 2'x 4'(0.61 m x 1.22 m) When used in most 2-5 ply BUR and SBS systems. 10,15 or 20 years Thickness* (1.91 cm) 12.54 cm) (3.81/cm) (5.08 cm) *Contact JM Technical Services for specific systems or terms over 20 years. Board Weight(lb) 6 7 12 15 W/Bundle 96 80 48 40 Codes and Approvals Boards/Bundle 12 10 5 Bundles/Pallet 10 10 10 DU Pallet Wei ht(lb) 715 740 740 MIAM4DADE CWNTYC US M;,mjj-YA Pallets per Truck* 48 APPROVED P,od tConlrolAM,...d Size 4'x 4'(1.22 m x 1.22 m) Thickness* 4/41 t/: (1.91 cm) (2.54 cm) (3.81 cm) .08 c Board Weight(lb) 12 15 24 3 Ftl/Pallet 960 800 480 400 Boards/Pallet 60 50 30 25 Pallet Weight(Ib) 715 735 715 735 Pallets per Truck** 48 Producing Location Rockdale,IL *N"and 1"thicknesses are homogenous,1%i"and 2"thicknesses are laminated **Assumes 48'flatbed truck. Refer to the Safety Data Sheet and product label prior to using this product. The Safety Data Sheet is available by calling(800)922-5922 or on the Web at www.jm.com/roofing. RS-5010 6-18(Replaces 8-16) [ESCO80oard Johns Manville Perlite-Based Cover Board Meets the requirements of ASTM C 728,Type 1 Typical Physical Properties Fesco Board Board Density,pcf(kg/ml), min C 209 8(128) r Compressive Strength 5%Consolidation,psi(kPa),nam C 165 30(207) Laminar Tensile Strength,psi(kPa),nom C 209 8(55) Flexural Strength,psi(kPa),nom C 203 65(448) Break Load,lbs,nom C 203 9(3/4 in.),13 0 in.),23(1%2 in.) Moisture Content,wt%,nam N/A 1.5 Water Absorption,%by vol,max C 209 1.5 o Linear Expansion,%,max C 209 0.5 Flute Span,in.(thickness),max E 661 1 (3/4 in.), 1.75(1 in.),2.5(1%2 in.) Weight per ft',lbs(thickness),nom NA 0.8(3/4"), 1 (1"►, 1.5(1%2"), 1.9(2") Thermal Performance Thickness R-Value(Resistance) in. mm 3/4 19 2.0 0.35 1 25 2.7 0.48 1%2 38 4.1 0.72 2 51 5.4 0.95 Test ASTM Fesco Board Flame Spread E 84 25 Smoke Developed E 84 10 O0k Fc O,o y Refer to the Safety Data Sheet and product label prior to using this product. The Safety Data Sheet is available by calling(800)922-5922 or on the Web at www.im.com/roofing. RS-5010 6-18(Replaces 8-16)