Loading...
1330 Ocean Boulevard POOL18-0045PERMIT PLAN POOL 30'X 17' W/ 3 WALL RETURNS & 1 PRESSURE CLEANER LINE . SPA 7' DIAMETER W/ 4 THERAPY JETS ].[�3'0" MINIMUM 3 T r TEE 1=1t 3" PIPE 3" PIPE 3" X 21/2" RED. BUSHING 21/2" TRUNK TO EQ. .APPROVED C"I POOL/SPA WITH HEAT PUMP & GAS HEATER FILTER SCHEMATIC THIS PLAN TO CORRELATE TO PERMIT SUBMITTED BY RJ ATLANTIC BUILDERS INC; EXISTING GARAGE IN POOL AREA TO BE DEMOLISHED BY GC. PROPERTY LINE AN UNDERGROUND BONDING CONDUCTOR MADE OF ASINGLE #8AkA(G BARE SOLID COPPER WIRE BURIED TO A MINIMUM DEPTH OF 4 INCHES TO 6 INCHES BELOW SUB GRADE, AND 18 INCHES TO 24 INCHES FROM INSIDE THE WALL OF A SWIMMING POOL OR SPA WILL BE USED. (3T RAISED BEAM WATERFALL W1 l-1 TWO 24" WATERFALLS O RAISED 6" - 12" - 6" 61 W POOLDEEP 17'- OOL POOL30' 17' 11,900 30' O� 1,900 GAL ONS SPATD 550 GA r— — — — — SUNSHEL 5' 10Y DEEP UMBRELLA (P ANCHOR BUBBLER N L— — — — — — — — ® —1 — — — — — — — — — ® F— — I I t I -4� 1111 1111 111 1 4 JUNCTION BOX ---.0 1j, " ' 51 ill --A M 0 "U M X SPA RAISED 12" M od SPASIDE REMOTE it PROPOSED LANAI POOL EQ17IPMENT EXISTING RESIDENCE Florida Building Code V` Edition (2017) Residential Conforms to Chapter 42 2014 National Electrical Code • NO OVERHEAD ELECTRIC IN POOLAREA • NO UNDERGROUND UTILITIES IN POOLAREA • FINISH GRADE TO SLOPE AWAY FROM POOL • VGB COMPLIANT MAIN DRAIN • DRAINAGE DETAIL— FINISH GRADE SLOPE AWAY FROM POOL • GROUNDING &- BONDING DETAIL PLUMBING LINE FROM POOL MAIN DRAINS TO POOL EQUIPMENT INSULATED #3 BOND WIRE IN CONDUIT FROM LIGHT NICHES THROUGH DECK BOX. LIGHT GFCI PROTECTED. PLUMBING LINE FROM POOL SKIMMER TO POOL EQUIPMENT BARE #8 BOND WIRE ATTACHED TO POOL STEEL APPROVED 1-�rlr COPING ONLY. NO DECK BY SURFSIDE. SETBACK MEASUREMENTS TAKEN FROM EDGE OF WATER TO PROPERTY LINE. SAFETY BARRIERS: FENCE & HOUSE / WINDOW ALARMS UP TO POOL SAFETY CODE. ALARMS TO MEET CODE UL2017. 0 CL Ws co co co C) o Il - N wco "X M 6,z -j M w U- 0 (D w w z (0 D Z Z I[ w W W W < F- > CO e W w W W Uj 0 z CD w M a Z OD 0 Cl) w C"I ui IW— 0 0 LL z -1 w U) z w z 0 0 z LU 6 a a. In 0 CL Ws M Z N wco M -j w U- > D Z Z LLj F- P. -1 0 Q� 0 Uj 0 z "T M a Z OD 0 Cl) C"I VIP 0 0 LL U) 0 z LU 0f U) w Oa (n 0 co -I 0 0 ®¢ i ai PERMIT PLAN POOL 30'X 17' W/ 3 WALL RETURNS & 1 PRESSURE CLEANER LINE SPA 7' DIAMETER W/ 4 THERAPY JETS 3'0" MINIMUM {� 3" TEE i =W PIPF 3" PIPE 1C X 2'/2" RED. BUSHING t--2',"" TRUNK TO EQ. i N N Nr r N N r N r r _ POOL/SPA WITH HEAT PUMP & GAS HEATER FILTER SCHEMATIC THIS PLAN TO CORRELATE TO PERMIT SUBMITTED BY RJ ATLANTIC BUILDERS INC; EXISTING GARAGE IN POOL AREA TO BE DEMOLISHED BY GC. PROPERTY LINE AN UNDERGROUND BONDING CONDUCTOR MADE OF A SINGLE #8 AWG BARE .SOLID COPPER WIRE BURIED TO A MINIMUM DEPTH OF 4 INCHES TO 6 INCHES BELOW SUB GRADE, AND 18 INCHES TO 24 INCHES FROM INSIDE THE WALL OF A SWIMMING POOL OR SPA WILL BE USED. (7) RAISED BEAM WATERFALL W1 TWO 24" WATERFALLS RAISED 6" -12" - 6" EXISTING RESIDENCE X .D M X r Z M Florida Building Code 61h Edition (2017) Residential Conforms to Chapter 42 2014 National Electrical Code • NO OVERHEAD ELECTRIC IN POOL AREA • NO UNDERGROUND UTILITIES IN POOL AREA • FINISH GRADE TO SLOPE AWAY FROM POOL • VGB COMPLIANT MAIN DRAIN • DRAINAGE DETAIL— FINISH GRADE SLOPE AWAY FROM POOL • GROUNDING & BONDING DETAIL PLUMBING LINE FROM POOL MAIN DRAINS TO POOL EQUIPMENT INSULATED #8 BOND WIRE IN CONDUIT FROM LIGHT NICHES THROUGH DECK BOX. LIGHT GFCIPROTECTED. PLUMBING LINE FROM POOL SKIMMER TO POOL EQUIPMENT BARE #8 BOND WIRE ATTACHED TO POOL STEEL LEGEND JANDY NICHELESS LED 11 =WALL 0 o = NOVA-. I� 18= STUB • • R CLEANER THERAPY UMBRELLA ANCHOR BUBBLER COPING ONLY. NO DECK BY SURFSIDE. SETBACK MEASUREMENTS TAKEN FROM EDGE OF WATER TO PROPERTY LINE. SAFETY BARRIERS: FENCE & HOUSE / WINDOW ALARMS UP TO POOL SAFETY CODE. ALARMS TO MEET CODE U L2017. 00 Co CO 6.0. -- - - -- - - - -- � r DEEP 1 O O I- 5 17" m O W W A 1 °� N UI POOL 30' 17' SPA ; J X N LO 11,500 GAL ONS RAISED 1 N m 12" SPA 7' DIA ETER 1 Qi 550 GALL NS ' w U) 0 z N O>- M ,' a.1 I �```4 O' II w 11 W a/ Q N I SPA SIDE " U �. 'OA/ V/ r - - - - REMOTE ; 1 w w { 1 1 w o r v❑ 1 1 1 p p GA 1 1 I SUNSHEL 5'10V - '10V3'0^ a .. 3'0'1 1 DEEP 1 ca I 1 1 I UMBRELLA N ' ANCHOR , ' 1 1 BUBBLER ♦ ' 1 Q p m p z Ir , z w z L---_®_®__ ___.._____ � -TI11 Q Q d Q z z U Q 0 w w w to D U O M p PROPOSED LANAI '' t JUNCTION BOX 10 POOL EQUIPMENT EXISTING RESIDENCE X .D M X r Z M Florida Building Code 61h Edition (2017) Residential Conforms to Chapter 42 2014 National Electrical Code • NO OVERHEAD ELECTRIC IN POOL AREA • NO UNDERGROUND UTILITIES IN POOL AREA • FINISH GRADE TO SLOPE AWAY FROM POOL • VGB COMPLIANT MAIN DRAIN • DRAINAGE DETAIL— FINISH GRADE SLOPE AWAY FROM POOL • GROUNDING & BONDING DETAIL PLUMBING LINE FROM POOL MAIN DRAINS TO POOL EQUIPMENT INSULATED #8 BOND WIRE IN CONDUIT FROM LIGHT NICHES THROUGH DECK BOX. LIGHT GFCIPROTECTED. PLUMBING LINE FROM POOL SKIMMER TO POOL EQUIPMENT BARE #8 BOND WIRE ATTACHED TO POOL STEEL LEGEND JANDY NICHELESS LED 11 =WALL 0 o = NOVA-. I� 18= STUB • • R CLEANER THERAPY UMBRELLA ANCHOR BUBBLER COPING ONLY. NO DECK BY SURFSIDE. SETBACK MEASUREMENTS TAKEN FROM EDGE OF WATER TO PROPERTY LINE. SAFETY BARRIERS: FENCE & HOUSE / WINDOW ALARMS UP TO POOL SAFETY CODE. ALARMS TO MEET CODE U L2017. w w z w M w 0 VE m O n D J m z Q w U 0 O Cl) M r r• C M M Cl) N N M J LL = w U w Cl m � � D z 0 m Z a � � Z z 0 o U) It cn w > D_ p W D Q U) m 00 Co CO r r r O O I- O N O r J X LO N N m W Oto w w w z N r it z II w W W W Q N a. U U U > w w w w o r v❑ p p p GA w a .. Iii ca Q p m p z z w z Q d Q z z U Q 0 w w w to D U O M p w w z w M w 0 VE m O n D J m z Q w U 0 O Cl) M r r• C M M Cl) N N M J LL = w U w Cl m � � D z 0 m Z a � � Z z 0 o U) It cn w > D_ p W D Q U) m CALCULATIONS: .0, GI 50.0, 811 I'd g. r e 6,. bIMPERVIOUS �s TOTAL LOT: 6,250 SCS FT I �I I 5 SfrFp;>6:=`fis$i HOUSE/PATIO: 1,845 SQ FT 000fr-l`a�= GARAGE/STEPS: 405 SQ FT I I P:,-STYD oal 2 -STY a <I '-} fr39a�ee DRIVEWAY: 859 SQ FT ARAGE n JI TOTAL IMPERVIOUS: 3,109 SQ FT I I z ' ISR: 50% iI 5' ,�,1 , ----- - I THIS PLAN TOC RRELATE WITH SAFETY BARRIERS:I 6- � PERMIT SUBMITTED BY RJ FENCE & HOUSE/WIPNDOW ALARMS j, ANROPOSED ,. L 51 5.. ATLANTIC BUILDERS INC. UP TO POOL SAFETY CODE. D I POOL%► EQUIPMENT ALARMS TO MEET CODE UL2017. co o LCA POOL / SPA COPING ONLY, NO DECKING BY SURFSIDE. EXISTING BLSTY CONC i RESIDENCE i O MM U SETBACK MEASUREMENTS TAKEN I ' I ! I NITYp � E�E�LOPM q w z _ FROM EDGE OF WATER TO I' I ~PPFjQw D� �w PROPERTY LINE. I; I o c� o w M i� I w� I SCALE: 1/20" = 1' j 50.0' S TE PLAN SCALE: = 1'-0" iDRAWN BY: BY: Dm; II/-8/lii� Joe F.RENER - S�ONG OCEAN BLVD NO:� S1 8 OF SHEEIS jg 6L �a�6��Lfi g�o 5§i�bS�:E�o�p .E�66o �a5Y� S � z �x U C/] CnC4 O U o W ch W � IDIUWN BY: nn �MWKW BY: C 1308 : 113�OL�F_ 4N I D 0: S1 8 a sr¢rs i Simplified Total Dynamic Head Calculation } Determine Maximum System flow Rate: 90 18. --_ 0 0.0 Swimming Pool Info: 373 3 to 6 to N/A Friction loss in suction pipe Volume: 11900 gallons ( Surface Area (Shallow) flow/friction loss chart) = 0.09 (Deep) (Shallow) 2" @ Spa Info: 38 3 Length of suction pipe 45 A3 Volume: 550 gallons ( Surface Area (Depth) 45 x Ft. of head per one foot of pipe 0.16 = 7.20 TDH in piping 9.1 11.4 13.7 15.9 12450 Total Volume Preferred Turnover Time in Hours : 6 # x 60 min. = 360 data sheet) 3.60 ( from filter data sheet) Main Drain 2.34 (Hours) 1 (tumover time in minutes) data sheet) Maxium Pool Flow Rate: 12450 divided by 3.30 360 35 gpm 48 = 83 gpm (gallons) (tumovertime in minutes) (flow rate pool) (feature flow rate) Spa Jets (#) 4 x 13 gpm per jet = 52 flow rate (# of jets) (jet flow) 11.6 `Total 5.64 s 18.3 A&A Quik Clean System NONE x 0 gpm Cleaner Head 0 flow rate NONE x 0 gpm Cleaner Head 0 flow rate NONE x 0 gpm Cleaner Head 0 flow rate (# of heads) (head flow) 16.2 18.4 0 Total Floor Heads flow rate Maximum Pool System Flow Rate: 83 4- Highest required flow nate between "Maximum Pool Flow 36.5 Rate" and "Spa Jets" and "Quick Clean System" Determine Pipe Sizes: 23.0 25.3 27.5 29.8 Pool/Spa: Branch piping to be: 3" 36.6 inch to keep velocity @ 6 f; s.Max.at : 136 gpm. Maximum System Flow Rate Trunk piping to be : 2.5" 25.3 inch to keep velocity @ 8 fl:)s.Max.at : 117 gpm. Maximum System Flow Rate Return piping to be 2" IZ inch to keep velocity @ 10 fps.Max.at : 103 gpm. Maximum System Flow Rate 23.1 Jandy Pro Series VS FloPro Series Pump VS-FHP7.6 Performance Curves 100 90 18. --_ 0 0.0 Distance from nearest edge of pool to pump in feet = 45 6.8 9.0 Friction loss in suction pipe 2.5" @ 8 fps inch pipe per one foot @ 117 gpm ( from pipe flow/friction loss chart) = 0.09 Friction loss in return pipe 2" @ 10 fps inch pipe per one foot @ 103 gpm ( from pipe flowffriction loss chart) = 0.16 Length of suction pipe 45 A3 Ft. of head per one foot of pipe 0.09 = 4.05 TDH in piping Length of pressure pipe 45 x Ft. of head per one foot of pipe 0.16 = 7.20 TDH in piping 9.1 11.4 13.7 15.9 TDH in piping 11.25 Other Loss in TDH ft. of head # Filter loss in TDH (from filter data sheet) 3.60 ( from filter data sheet) Main Drain 2.34 2.34 1 r data sheet) 0.00 (from heater data sheet) Returns 3/4" 3.30 3.30 1 "Total all other loss 5.64 Therapy Jet 0.00 27.72 0 Pool Total Dynamic Head (TDH) 20 Floor System 0.00 19.65 0 5 11.6 `Total 5.64 s 18.3 20.6 22.9 25.1 27.4 29.6 31.9 S 13.9 1 16.1 18.4 20.6 1 22.9 25.2 1 2T.4 29.7 31.9 34.2 � 16.2 18.4 20.7 23.0 25.2 27.5 1 29.7 32.0 34.3 36.5 18.5 20.7 23.0 25.3 27.5 29.8 32.0 34.3 36.6 26 d 23.1 25.3 27.6 29.8 32.1 340 RPF IZ 1 41.1 07 10 23.1 25.4 27.6 29.9 32.1 34.4 36.7 38.9 so 43.4 L1 25.4 27.7 29.9 32.2 34.5 36.7 39.0 41.2 43.5 45.8 1, 12 27.7 30.0 32.2 1 34.5 36.8 39.0 41.3 43.5 45.8 48.1 13 30.0 1 32.3 34.6 36.8 1 39.1 41.3 43.6 45.9 48.1 50.4 14 - 34.6 _.. 17 b' 43.6 45.9 48.2 50.4 52.7 2 /RF 34.7 36.9 39.2 41.4 43.7 1 46.0 48.2 50.5 52.7 55.0 '..; IS 37.0 4� 41.5 43.7 46.0 48.3 1 50.5 1 52.8 55.0 57.3 L :I 17- 39.3 41.5 43.8 46.1 48.3 50.6 1 52.8 55.1 57.4 59.6 {ry i 41.6 43.8 46.1 48.4 50.6 52.9 55.1 57.4 59.7 61.9 ilY 19 43.9 46.2 1 48.4 50.7 52.9 55.2 57.5 59.7 62.0 13 20 j 20 46.2 485 50.7 53.4 1 55.2 57.5 59.8 62.0 64.3 66.5 0- 21 48.5 50.8 53.0 55.3 57.6 59.8 62.1 9 66.6 68.9 22 17 RP 55.3 57.6 59.9 62.1 64.4 66.6 1 68.9 71.2 CL 1 23 53.1 55.4 57.7 59.9 62.2 64.4 66.7 69.0 71.2 73.5 `,... 24 55.4 57.7 60.0 62.2 64.5 66.7 69.0 71.3 73.5 75.8 '- 2S 5T.8 60.0 62.3 64.5 66.8 69.1 1 I IRP 75.8 78.1 26 60.1 62.3 64.6 66.8 69.1 71.4 73.6 75.9 78.1 80.4 27 62.4 64.6 0 69.2 71.4 73.7 75.9 78.2 80.5 82.7 28 64.7 66.8 69.2 1 71.5 73.7 76.0 78.2 80.5 82.8 55.0 20 0 0 10 20 80 40 60 80 70 W 90 100 110 120 180 W 150 160 170 160 190 200 Fi - Rab. Ga.- Per IMnub. (GPIM Determine Simplfied TDH (POOL); 18. --_ 0 0.0 Distance from nearest edge of pool to pump in feet = 45 6.8 9.0 Friction loss in suction pipe 2.5" @ 8 fps inch pipe per one foot @ 117 gpm ( from pipe flow/friction loss chart) = 0.09 Friction loss in return pipe 2" @ 10 fps inch pipe per one foot @ 103 gpm ( from pipe flowffriction loss chart) = 0.16 Length of suction pipe 45 x Ft. of head per one foot of pipe 0.09 = 4.05 TDH in piping Length of pressure pipe 45 x Ft. of head per one foot of pipe 0.16 = 7.20 TDH in piping 9.1 11.4 13.7 15.9 TDH in piping 11.25 Other Loss in TDH ft. of head # Filter loss in TDH (from filter data sheet) 3.60 ( from filter data sheet) Main Drain 2.34 2.34 1 Heater loss in TDH (from heater data sheet) 0.00 (from heater data sheet) Returns 3/4" 3.30 3.30 1 "Total all other loss 5.64 Therapy Jet 0.00 27.72 0 Pool Total Dynamic Head (TDH) 20 Floor System 0.00 19.65 0 5 11.6 `Total 5.64 16.1 18.3 20.6 22.9 Pool Pump: Jandy FloPro VS -FHP 1 hP 83 Gallons Per Minute 20 Total Dyn Imi1 Pool Filter: Jandy CS150 Cartridge Heater: JXi400P Jandy Pro Series (LPga:1 Pool ® Nova 7-3/4" Pool lDra Main Drain: 3ft.0in. Floor Installation @ 150 gpm max. flow Head (TDH) Nsign Head Loss (ft heed Jandy 1Yartridge Finer, Cs series 0 30 60 90 Flow Rate (gpm) 1291 Design Pressure Drop (psi) 08150 CS200 CS250 CS100 Peals o Spas o Service Robert & Laura Ebener 1330 Ocean Blvd. Atlantic Beach 32233 12/20/2018 Total Heed in Feet Conversion Chart Inches IVIercury (Vacuum Gauge) 0 2-_ _ 4- .. 8 10 12 14 �16 18. --_ 0 0.0 2.3 4.5 6.8 9.0 11.3 13.6 15.8 18.1 20.3 -_ 1 2.3 4.6 6.8 3.1 11.4 13.6 15.9 18.1 20.4 22.7 _ 4.6 6.9 9.1 11.4 13.7 15.9 18.2 20.4 22.7 25.0 I 3 6.9 9.2 11.5 13.7 16.0 18.2 20.5 22.8 25.0 27.3 4 9.2 11.5 13.8 16.0 18.3 20.5 22.8 25.1 27.3 29.6 5 11.6 13.8 16.1 18.3 20.6 22.9 25.1 27.4 29.6 31.9 S 13.9 1 16.1 18.4 20.6 1 22.9 25.2 1 2T.4 29.7 31.9 34.2 % 16.2 18.4 20.7 23.0 25.2 27.5 1 29.7 32.0 34.3 36.5 18.5 20.7 23.0 25.3 27.5 29.8 32.0 34.3 36.6 38.8 23.1 25.3 27.6 29.8 32.1 34.4 36.6 1 38.9 1 41.1 07 10 23.1 25.4 27.6 29.9 32.1 34.4 36.7 38.9 41.2 43.4 L1 25.4 27.7 29.9 32.2 34.5 36.7 39.0 41.2 43.5 45.8 1, 12 27.7 30.0 32.2 1 34.5 36.8 39.0 41.3 43.5 45.8 48.1 13 30.0 1 32.3 34.6 36.8 1 39.1 41.3 43.6 45.9 48.1 50.4 14 32.3 34.6 36.9 39.1 41.4 1 43.6 45.9 48.2 50.4 52.7 15 34.7 36.9 39.2 41.4 43.7 1 46.0 48.2 50.5 52.7 55.0 '..; IS 37.0 39.2 41.5 43.7 46.0 48.3 1 50.5 1 52.8 55.0 57.3 L :I 17- 39.3 41.5 43.8 46.1 48.3 50.6 1 52.8 55.1 57.4 59.6 {ry 18 41.6 43.8 46.1 48.4 50.6 52.9 55.1 57.4 59.7 61.9 ilY 19 43.9 46.2 1 48.4 50.7 52.9 55.2 57.5 59.7 62.0 64.2 j 20 46.2 485 50.7 53.4 1 55.2 57.5 59.8 62.0 64.3 66.5 0- 21 48.5 50.8 53.0 55.3 57.6 59.8 62.1 64.3 66.6 68.9 22 50.8 53.1 55.3 57.6 59.9 62.1 64.4 66.6 1 68.9 71.2 CL 1 23 53.1 55.4 57.7 59.9 62.2 64.4 66.7 69.0 71.2 73.5 `,... 24 55.4 57.7 60.0 62.2 64.5 66.7 69.0 71.3 73.5 75.8 '- 2S 5T.8 60.0 62.3 64.5 66.8 69.1 1 71.3 73.6 75.8 78.1 26 60.1 62.3 64.6 66.8 69.1 71.4 73.6 75.9 78.1 80.4 27 62.4 64.6 66.9 1 69.2 71.4 73.7 75.9 78.2 80.5 82.7 28 64.7 66.8 69.2 1 71.5 73.7 76.0 78.2 80.5 82.8 55.0 20 67.0 69.3 71.5 73.8 76.0 78.3 80.6 82.8 1 85.1 87.3 30 69.3 71.6 73.8 76.1 78.3 80.6 82.9 85.1 87.4 89.6 9 31 71.6 73.9 76.1 78.4 80.7 82.9 85.2 87.4 89.7 92.0 =. 32 73.9 76.2 78.4 80.7 83.0 85.2 87.5 89.7 92.0 94.3 33 76.2 78.5 80.8 83.0 85.3 87.5 89.8 92.1 94.3 96.6 1 34 78.580.8 1 83.1 85.3 87.6 89.8 92.1 94.4 96.6 98.9 35 80.9 83.1 1 85.4 87.6 89.9 92.2 94.4 96.7 98.9 101.2 Nsign Head Loss (ft heed Jandy 1Yartridge Finer, Cs series 0 30 60 90 Flow Rate (gpm) 1291 Design Pressure Drop (psi) 08150 CS200 CS250 CS100 Peals o Spas o Service Robert & Laura Ebener 1330 Ocean Blvd. Atlantic Beach 32233 12/20/2018 JOB SPECIFIC PIPE SIZING, TOTAL DYNAMIC HEAD CALCULATIONS AND EQUIPMENT SPECIFICATIONS AND DOCUMENTATION ARE TO BE PROVIDED BY THE POOL CONTRACTOR FOR EACH PROJECT. THE POOL GONTRACTOR-MUST USE THE MAXIMUM FLOW CAPACITY OF THE SELECTED PUMP AND PROVIDE HYDRAULIC CALCULATIONS FOR TDH TO DETERMINE PROPER PUMP AND PIPING SIZING. THE MANUFACTURER'S EQUIPMENT SPECIFICATIONS AND OTHER DOCUMENTATION FOR PUMPS, FILTERS, NEATER EQUIPMENT AND MAIN DRAINS AND COVERS ARE TO BE SUBMITTED FOR REVIEW AND DOCUMENTATION FOR SIZING THE CIRCULATION SYSTEM. CPLORINATC POOL FILTER THE MAIN DRAIN PIPE INVERT NEEDS TO BE 1.5 TIMES THE DIAMETER DOWN FROM THE TOP OF THE MAIN DRAIN GRATE TO THE TOP OF THE MAIN DRAIN PIPE, IF THE PIPE COMES IN VERTICAL TO THE MAIN DRAIN BOX. IF THE MAIN DRAIN PIPE COMES INTO THE MAIN DRAIN BOX HORIZONTALLY, THE COVER FROM THE TOP OF THE GRATE TO THE TOP OF THE MAIN DRAIN PIPE NEEDS TO BE 1.5 TIMES THE DIA. OF THE MAIN DRAIN PIPE. 2-a3 BARS - 1 -1/2 TIMES THE DIA. I -I/2 TIMES THE DIA. CONT. IN _ 8'X8" BOND BEAM RAIN MAIN DRAIN DRAIN RETURN LINE ______-r_____________________________ II Il (OPTION WALL RETURNS) l II 11 II II it RETURN INLET j (OPTION WALL RETURNS) RETURN INLET" II UNDERWATER LIGHT (OPTION WALL RETL N DRAIN CTION / ------- -�� MAIN DRAINS MEET THE VIRGINIA GRAEME BAKER POOL AND SPA SAFETY ACT. SUCTION i i i i III jl mf'E III I� ___________ ill LL- J ll N J— Il 1 lil �it > (I I i I FLOOR RETURN I I III l i 3 REQ'D. I I I RETURN �L RETURN INLET FRET I i %IR / tOPTI I I // I I I I �FI'I II Ill-------=iKIMMER Ij --------------------------------- RETURN LINE (OPTION WALL RETURNS) LOW PROFILE JUNCTION 4.0' SWIM BOX- mw OUT UL APPROVED UNDERWATER LIGHT POOL SHELL 3000 F51 PUMP MIX CONCRETE PNEUMATICALLY APPLIED. 0110 6"-l" IN VERTICAL WALL5 (TYPJ oo, V-8" IN COVES AND FLOOR5 ITYPJ V 2500 MIN. GUNITE MAY BE SUBSITIUTED °oo (�D�EEPD FOR 3000 PSI CONCRETE FLOORINFORGEM E BREAK - 03 BAR ® 12" ON C 03 BAR® G"ONG / IF ----=_ - Zit RETURN INLET N5) _ � II iii =�===JL lV I INLET WALL RETURN5) TYPIGAL SJ-IIMMING POOL 03 BARS GRADE 40,12" O.G. CERAMIC TILE VERTICAL AND HORIZONTAL (TYP) WATER LINE 1/2" QUARTZ FINISH --------------- AMAIN DRAIN W/ RELIEF PLUG OR 2" HYDROSTATIC RELIEF VALVE, IF REQ'D. ROCKBED EACH WAY < 8.0' DEEP EACH WAY > 8.0' DEEP AND OVER. SV41MMING POOL SECTION WATER LINE ST G" OF WATER LINE TILES DECK OVER POUR OR BRICK COPING 15.11 15"1 I-»3 BAR CONT. IN 5" THICK BOND BEAM ALTERNATE BEAM FINISH DETAIL PAVER DECKING OR 4" THICK CONCRETE DECK W/ FIBER MIX 2500 P51 OR WIRE MESH GENERAL NOTES: I. POOL 15 TO BE BUILT TO COMPLY WITH FLORIDA, COUNTY AND CITY BUILDING CODES. 2. ALL METAL PARTS WITHIN 5 FT. WILL BE GROUNDED AS PER NATIONAL ELECTRIC CODE AND AS REQUIRED BY LOCAL INSPECTOR. 3. FILTRATION SYSTEM WILL HAVE SUFFICIENT CAPACITY TO PROVIDE A COMPLETE TURNOVER OF POOL WATER IN (12) TWELVE HOURS OR LESS. 4. POOL CONSTRUCTION TO BE THE SAME REGARDLESS OF SIZE AND SHAPE. IF FILL 15 REQUIRED FOR 2 FT. TO 4 FT. OF WALL HEIGHT THEN WALLS HAVE TO BE REINFORCED WITH ADDITIONAL STEEL (8" O.G. BOTH WAYS) AND/ OR EXTRA WALL THICKNESS (8" TO 10") 5. ALL PVC PIPE WILL BE SCHEDULE 40. 6. ALL METAL FIXTURES AND POOL LIGHTS TO BE BONDED TO POOL STEEL AND GROUND WIRE, 1. POOL ALARMS DO NOT NEED TO BE HARDWIRED S. SOIL CONDITIONS AT POOL LOCATION ARE ASSUMED TO BE ADEQUATE FOR A SINGLE FAMILY DWELLING. 9. TERMITE CONTROL WILL BE APPLIED UNDER ALL POOL DECKS. 10. ALL PUMPS AND FILTERS WILL BE ANCHORED TO A CONCRETE PAD WITH TAP CON ANCHORS. II. ALL POOL AND SPA SUCTION INLETS SHALL BR PROVIDED WITH A COVER THAT HAS BEEN TESTED AND ACCEPTED BY A RECOGNIZED TESTING FACILITY AND COMPLY WITH A.N.S.IJA.511.E. A112.19, 8M, "SUCTION FITTINGS FOR USE IN SWIMMING POOLS, SPAS, HOT TUBS, AND WHIRLPOOLS BATHTUB APPLIANCES" 12. THE POOL DESIGN WILL MEET CHAPTERS 42 AND 45 OF THE 2011 FLORIDA BUILDING CODE 6TH EDITION. 13. RESIDENTIAL POOLS MUST COMPLY WITH CHAPTERS 42 AND 45 OF THE 2011 FLORIDA BUILDING CODE GTP EDITION. 14. POOL CONSTRUCTION WILL MEET 2014 NATIONAL ELECTRIC CODE. SEE 68026 (5)(2)(b) FOR PERIMETER BONDING U51NO AT LEAST ONE(I) a8 AWG BARE SOLID COPPER CONDUCTOR. 15. FOR RESIDENTIAL POOLS UP TO A WATER DEPTH OF 8'-0" 03 REBAR 12" O.C.B W. OVER 8'-0"; SPECIAL ENGINEERING 15 REQUIRED AND 15 NOT A PART OF THIS DRAWING SPECIFICATIONS. WALL THICKNESS SHALL PROVIDE CODE COVER OVER REINFORCING. FOR OVER 8'-0" A SPECIAL DESIGN WILL BE REQUIRED. 16. RESIDENTIAL POOLS SHALL COMPLY WITH THE AN51/AP5P/ICC-5 2011 FOR RESIDENTIAL INGROUND POOL5, AN51/APSPACG-3 2014 FOR PERMANENTLY INSTALLED RESIDENTIAL SPAS, AND ANSI/AP5P/IGC--I 2013 FOR SUCTION ENTRAPMENT AVOIDANCE STANDARDS. AND AN51/APSPACG-15A 2013 STANDARD FOR RESIDENTIAL SWIMMING POOL AND SPA ENERGY EFFICIENCY IT DO NOT USE OR OPERATE POOL OR SPA IF THE SUCTION FITTING 15 MISSING, BROKEN, OR LOOSE. 18. IF THE SUCTION INLET SYSTEM, SUCH AS AN AUTOMATIC CLEANING SYSTEM, 15 A VACUUM CLEANER SYSTEM WHICH HAS A SINGLE SUCTION INLET, OR MULTIPLE SUCTIONS INLETS WHICH CAN BE ISOLATED BY VALVES, THEN EACH SUCTION INLET SHALL PROTECT AGAINST USER ENTRAPMENT BY EITHER AN APPROVED ANTI -VORTEX COVER, 12" X 12" GRATE OR LARGER, OR OTHER APPROVED MEANS. COMPACTED SOIL UNDER PARKER M YNCPENBERG 4 INC CONCRETE DECK ASSOC.V VV 11 PROFESSIONAL ENGINEERS LANDSCAPE ARCHITECTS 1729 RIDGEWOOD AVENUE HOLLY HILL FLORIDA 32111 (386) 677-6891 FAX (386) 677-2114 03 BAR5 12" ON CENTER NOT VALID WITHOUT EACH WAY (GRADE 40) EMBOSSED SEAL. ijRil�'aj li a ,e f . c ` :F,L- B PARKER MYN HENB ERG, P;E " #32645 TYPICAL RES 1 DENTAL SW/POOL DESIGN FOR SURFSIDE POOLS 313 BEACH BOULEVARD JACKSONVILLE BEACH, FL. 32250 (904) 246-2666 STATE LICENSE OP0044080 THIS SIGNED AND SEALED SHEET 15 TO BE USED AS A MASTER FILE COPY . IT WILL BE USED FOR A MAXIMUM PERIOD OF ONE YEAR EXPIRING ON 12/31/18. IF THE FLORIDA BUILDING CODE 15 ALTERED OR MODIFIED BEFORE THAT DATE, THIS DRAWING MAY BE RENDERED VOID. SHEET I OF 5 REGIRGULATION fl"'"" GHLORINATC POOL FILTER THERAPY JET RETURN LINE \ II II I! it II I Mil I MAIN DRAIN (SUCTION) i I --------------- - --- mZ I � � I I II I €iE€! II it II II RETURN LINE ------------------------�I .--------------------._---� II II II II IL-------------- ----- -- ---�I L ------------------------- -----J MAIN DRAINS MEET l HE VIRGINIA GRAEME BAKER POOL AND VA SAFETY ACT. (SECOND MAIN DRAIN MAY BE ON SIDE WALU TYPICAL SPA POOL -• 2 MAIN DRAINS ON FLOOR POOL SHELL 3000 P51 CONCRETE PNEUMATICALLY APPLIED. G" IN VERTICAL WALLS (TYP) 6" IN COVES AND FLOORS (TYP) 2500 MIN. GUNITE MAY BE SUBSITIUTED FOR 3000 PSI CONCRETE 1/2" QUARTZ FINISH VARIES UL APPROVED UNDERWATER LIGHT TED SOIL UNDER I ' UNDER GONGETE DECK MAIN DRAIN DECK W/ FIBERMIX SUCTION LINE ------------------------- - WATER LINE 0 0 6"X6" CERAMIC TILE 0 p 800 � LOW PROFILE 0600 MAIN DRAIN W/ RELIEF 000c PLUG OR 2" p00oa HYDROSTATIC RELIEF 0 o VALVE, IF REQV. 0.�oa 5ECTION UNDERWATER LIGHT 3/4" BULLNOSE TILE OPTIONAL ON EDGE OF STEP. PAVER DECKING OR 4" THICK CONCRETE THE MAIN DRAIN PIPE INVERT NEEDS TO BE 1.5 TIMES THE DIAMETER DOWN FROM THE TOP OF THE MAIN DRAIN GRATE TO THE TOP OF THE MAIN DRAIN PIPE, IF THE PIPE COMES IN VERTICAL TO THE MAIN DRAIN BOX. IF THE MAIN DRAIN PIPE COMES INTO THE MAIN DRAIN BOX HORIZONTALLY, THE COVER FROM THE TOP OF THE GRATE TO THE TOP OF THE MAIN DRAIN PIPE NEEDS TO BE 1.5 TIMES THE DIA. OF THE MAIN DRAIN PIPE, 1-1/2 TIMES THE DIA, 1-1/2 TIMES THE DIA. MAIN MAIN DRAIN DRAIN GAP TILE/ BRICK/ OR CANTILEVER WITH WATERLINE TILE 2-03 REBAR CONTINUOUS STEEL REINFORCED CONCRETE — DECK AND TILE DETAIL NOT VALID WITHOUT EMBOSSED SEAL'.' • i � t`4 �j_ - 5J E B a .6 2018 PARKER MYNCHENBERG, P.E. 0326645 ACRLYIC FIN15H PARKER MYNOPENSERG 4 A5500. INC PROFESSIONAL ENGINEERS LANDSCAPE ARCHITECTS 1129 RIDGEWOOD AVENUE HOLLY HILL FLORIDA 32111 (586) 6"11-6891 FAX (386) 611-2114 TYPICAL RE51 DENTAL 5W/POOL DESIGN FOP, SURFSIDE POOLS 313 BEACH BOULEVARD JACKSONVILLE BEACH, FL. 32250 (904) 246-2666 STATE LICENSE CPC044080 THIS SIGNED AND SEALED SHEET 15 TO BE USED AS A MASTER FILE COPY . IT WILL BE USED FOR A MAXIMUM PERIOD OF ONE YEAR EXPIRING ON 12/31/18. IF THE FLORIDA BUILDING CODE 15 ALTERED OR MODIFIED BEFORE THAT DATE, THIS DRAWING MAY BE RENDERED VOID. SHEET 2 OF 5 DECK W/ FIBERMIX 3000 PSI WATER LINE 6"X6" CERAMIC TILE LOW PROFILE JUNCTION BOX MIN. I EXTRA 03 BARS — CONTINUOUS #3 BARS 12" O.G. 00800°0 VERTICAL AND 0-.00 HORIZONTAL (TYP) (GRADE 40) DOoo 80000 000 ,O ROGKBED THE MAIN DRAIN PIPE INVERT NEEDS TO BE 1.5 TIMES THE DIAMETER DOWN FROM THE TOP OF THE MAIN DRAIN GRATE TO THE TOP OF THE MAIN DRAIN PIPE, IF THE PIPE COMES IN VERTICAL TO THE MAIN DRAIN BOX. IF THE MAIN DRAIN PIPE COMES INTO THE MAIN DRAIN BOX HORIZONTALLY, THE COVER FROM THE TOP OF THE GRATE TO THE TOP OF THE MAIN DRAIN PIPE NEEDS TO BE 1.5 TIMES THE DIA. OF THE MAIN DRAIN PIPE, 1-1/2 TIMES THE DIA, 1-1/2 TIMES THE DIA. MAIN MAIN DRAIN DRAIN GAP TILE/ BRICK/ OR CANTILEVER WITH WATERLINE TILE 2-03 REBAR CONTINUOUS STEEL REINFORCED CONCRETE — DECK AND TILE DETAIL NOT VALID WITHOUT EMBOSSED SEAL'.' • i � t`4 �j_ - 5J E B a .6 2018 PARKER MYNCHENBERG, P.E. 0326645 ACRLYIC FIN15H PARKER MYNOPENSERG 4 A5500. INC PROFESSIONAL ENGINEERS LANDSCAPE ARCHITECTS 1129 RIDGEWOOD AVENUE HOLLY HILL FLORIDA 32111 (586) 6"11-6891 FAX (386) 611-2114 TYPICAL RE51 DENTAL 5W/POOL DESIGN FOP, SURFSIDE POOLS 313 BEACH BOULEVARD JACKSONVILLE BEACH, FL. 32250 (904) 246-2666 STATE LICENSE CPC044080 THIS SIGNED AND SEALED SHEET 15 TO BE USED AS A MASTER FILE COPY . IT WILL BE USED FOR A MAXIMUM PERIOD OF ONE YEAR EXPIRING ON 12/31/18. IF THE FLORIDA BUILDING CODE 15 ALTERED OR MODIFIED BEFORE THAT DATE, THIS DRAWING MAY BE RENDERED VOID. SHEET 2 OF 5 POOL BONDING NOTES: 1. EQUIPOTENTIAL BONDING OF PERIMETER SURFACES REQU COPPER CONDUCTOR; MINIMUM 08 AWG BARE SOLID COPE CONDUCTOR WHICH FOLLOWS THE CONTOUR OF THE PERI SURFACE OF THE POOL FROM 18" TO 24' FROM THE IN51DI OF THE POOL AND WHICH IS SECURED WITHIN OR UNDER' PERIMETER SURFACE 4" TO 6" BELOW SUBGRADE. THE PE BONDING SHALL BE ATTACHED TO THE POOL REINFORCIt AT A MINIMUM OF 4 POINTS UNIFORMLY SPACED AROUND' PERIMETER OF THE POOL. 2. ALL UNDERGROUND OR UNDER SLAB CONNECTIONS SHA PER NEC 250.8. BONDING CABLES UNDER SLAB SHALL OF EXCAVATION. 3. 4. 5. 6. 1. Il WALLS BE BY LISTED MEANS PLACED AT THE BOTTOM WHEN REBAR IS UTILIZED FOR THE CONSTRUCTION OF PLANTERS AND FOOTERS ADJACENT TO THE POOL (WITHIN 5 FT), THIS REBAR SHALL BE BONDED USING #8 AWG BARE "SOLID COPPER CONDUCTOR BY LISTED MEANS PER NEC 250.8 TO THE BONDING CONDUCTOR. LOCATION OF COPPER BONDING CONDUCTOR, BONDING JUMPERS, AND CONNECTIONS SHOWN ARE DIAGRAMMATIC ONLY. CONTRACTOR SHALL FIELD ROUTE TO DETERMINE EXACT LOCATION. BONDING CONDUCTOR SHALL CONFORM TO THE SHAPE OF THE POOL WHILE MAINTAINING SMOOTH RADIAL CURVES - NO 90' RADIUS SHALL BE PERMITTED. RESISTANCE OF THE GROUND SYSTEM SHALL NOT EXCEED 25 OHMS. IF REQUIRED, ALL GROUND RODS SHALL BE 5/8" COPPER CLAD STEEL, 8' LONG AND DRIVEN TO A DEPTH OF 28" BELOW FINISHED GRADE, MINIMUM, AND WHERE USED SHALL BE BONDED USING 08 AWG BARE SOLID COPPER CONDUCTOR BY LISTED MEANS PER NEC 250.8 TO THE BONDING CONDUCTOR. SPECIAL CASES MAY INCLUDE, BUT ARE NOT LIMITED TO, VANISHING EDGE POOLS, POOLS WITH PERIMETERS OF VARYING (VERTICAL) GRADE'S, DIMINISHED PERIMETER SURFACES LIKE EDGE PLANTERS, STOP/RETAINING WALLS, AND ZERO -LOT LINES. IN THESE CASES, THE BONDING CONDUCTOR SHALL BE INSTALLED IN ACCORDANCE WITH NEC 680.26, NOTE I (ABOVE), AND DIRECTION FROM THE AUTHORITY HAVING JURISDICTION (AHJ). THE ELECTRICAL CONTRACTOR SHALL!_ BE RESPONSIBLE FOR COORDINATION OF THE BONDING WITH THE AHJ IN THE DE'T'ERMINATION OF IT!E�YPICAL APPLICATION OF THE NEC. LADDER, HANDRAIL, DIVING BOARD, ETC PUMP MOTOR METAL CONDUITS OR PIPING SYSTEM— POOL REINFORCING STEEL NEATER III o Illf 1 0 TYPICAL POOL BONDING NOT TO SCALE SCHEMATIC NOTES: I. TWE EQUIPOTENTIAL BONDING OF ALL CONDUCTIVE POOL 5 METALLIC COMPONENTS, UNDERWATER LIGHTING, METAL FITI AND METAL WIREWAYS/CONDUITS SHALL BE IN ACCORDANO ACCEPTED BY THE AUTHORITY HAVING JURISDICTION (AHJ). BOND JUMPER NOTE q TYPICAL JUNCTION BOX (IF USED) S. COPPER BONDING CONDUCTOR SHALL BE BONDED TO THE POOL AND SPA REBAR AS SHOWN, 4 LOCATIONS, 1'11NIMUrl AT EACH SEPARATE BODY OF WATER, USING A #8 AWG BARE SOLID COPPER CONDLI-;TOR. FOR NON-CONDUCTIVE POOL SHELLS, BONDING AT 4 POINTS SHALL NOT BE rZEQUIRED. q. COPPER BONDING CONDUCTOR SHALL BE BONDED TO THE EQUIPMENT GROUND OF THE POOL PUMP MOTOR AND OTHER ELECTRICAL COMPONENTS AS REQUIRED BY NEC 68026 (VERIFY LOCATIONS) USING #8 AWG BARE SOLID COPPER WIRE. 10. COPPER BONDING CONDUCTOR SHALL BE BONDED TO ALL METALLIC COMPONENTS OF THE POOL AND SPA AND THE- METAL STRUCTURES, INCLUDING, BUT NOT LIMITED TO, ALL HANDRAILS, DIVING BOARDS, AND LADDER GRABRAIL5 IN THE POOL AND SPA AND AND INCLUDE ALL METAL WIF• ING AND ALL FIXED METAL PARTS THAT ARE WITHIN 5 FT. HORIZONTALLY OF THE IN5111f WALL OF THE POOL (SPA) AND 12 FT VERTICALLY ABOVI THE MAXIMUM WATER LEVEL OF THE POOL USING #8 AWG BARE COPPER WIRE. II. ALL POOL AND SPA LIGHTING NICHES SHALL BE BONDED TO POOL AND SPA REBAR PER NEC 680. THE COPPER OONDING CONDUCTOR SHALL BE BONDED TO THE REBAR AT BOTH THE POOL AND THE SPA, PER NOTE 8, ABOVE, WHICH SHALL, IN TURN, PROVIDE BONDING OF THE LUMINAIRE NICHES. 12. ELECTRICAL CONTRACTOR SHALL CALL FOR THE INSPECTION OF THE BONDING OF THE POOL AND ITS PERIMETER SURFACES PRIOR TO COVER-UP OF THESE AREAS. NOTE I NOTES 2 AND 3 NOTE 3 I / �� BOND JUMPER I NOTE 8 TYPICAL BOND JU NOTE 10 TYPICAL 13 SWIMMING POOL LT FIXTURE YGLZI NOTE Il NOTES I, 4, 13 TYPICAL 5 AND 8 TYPICAL POOL BONDING PLAN NOT TO SCALE POOL LIGHT NICHE CONTROL PANEL(5) TIC PERIMETER 5URFACE5, ELECTRICAL EQUIPMENT, I NEC 68026. OR, AS BONDING LEGEND • BOND CONNECTION, PER NEC 250.8 o PARALLEL TAP CONNECTION, PER NEC 250.8 UNDERGROUND BONDING CONDUCTOR, 08 AWG (MINIMUM) NOTE I MINIMUM 5/8" DIAMETER COPPER GROUND ROD DRIVEN UNTIL MAXIMUM RESISTANCE VALUE OF 25 OHMS IS REACHEDNOTE I (IF USED) IN TYPICAL BONDING TYPES NOT TO SCALE 'OR FROM POOL REBAR OR BONDING CONDUCTOR NOTES: 1. SPLICES (WELDED OR MECHANICAL) SHALL BE PERFORMED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. NOT V LID WITHOUT . EMBO SETJ -,S/EAL. ec' � '' '�9 I iA ,� s l ✓T s+' pi: PARKER MYNCHENBERG P.E.0326 5 < PAR ,ER MYNCHENBERG 4 ASSOC. INC PROFESSIONAL ENGINEERS LANDSCAPE ARCHITECTS 1129 RIDGEWOOD AVENUE HOLLY HILL FLORIDA 32111 (386) 611-68gl FAX (386) 611-2114 TYPICAL RE51 DENTAL SW/POOL DESIGN FOR SURF5IDE POOLS 313 BEACH BOULEVARD JACKSONVILLE BEACH, FL. 32250 (904) 246-2666 STATE LICENSE OPCO44080 THIS SIGNED AND SEALED SHEET IS TO BE USED AS A MASTER FILE COPY . IT WILL BE USED FOR A MAXIMUM PERIOD OF ONE YEAR EXPIRING ON 12/31/18. IF THE FLORIDA BUILDING CODE 15 ALTERED OR MODIFIED BEFORE THAT DATE, THIS DRAWING MAY BE RENDERED VOID. SHEET 3 OF 5 4" DECK «3 BAR AT 12' ON CENTER BAR TO BE 5 FT LONG TURN DOWN FOOTER DETAIL 1-p3 BAR BRICK PAVER /CONTINUOUS POOL DECK m QO 1-03 BAR VERTICALLY 4! ry ® 36" ON CENTER r < 1-a3 BAR — CONTINUOUS PAVER DECK TURNDOWN DETAIL 04 BAR AT 12" ON CENTER MIN B=1/2" X A 04 BAR AT 12" ON CENTER wil 32" 4 FT RETAINING WALL RETAINING WALL 3000 P51 PUMP MIX CONCRETE uD IFTIN TO IFTIN (2) 03 REBAR CONT. MOTERATE 5LOPE FOOTING TYPE 2 BAR AT 12" ON CENTER 04 BAR AT 12" ON CENTER �g" , FI 24" 2 I=T RETAINING WALL RETAINING WALL 3000 P51 PUMP MIX CONCRETE #4 BAR AT 12" ON CENTER i #3 REBAR CONT. a IFT IN6 ry OR STEEPER �%% t✓. e, r ;» STEEP SLOPE FOOTING TYPE 2 SLAB -FOOTING DETAIL5 2500 MIN. GUNITE MAY BE SUBSITIUTED FOR 3000 P51 CONCRETE USE 6X6 10/10 WWM OR FIBER MESH CURE FOR ONE WEEK BEFORE INSTALLING ANCHORS. CONCRETE PAVER DECK 12" 3000 P51 CONCRETE W/ 2-k3 REBARS RIBBON FOOTING W/ PAVER DECK 04 BAR AT 12" ON CENTER l 24" 'l 5 FT RETAINING WALL RETAINING WALL 3000 P51 PUMP MIX CONCRETE THE POOL CONTRACTOR SHALL PLACE ALL STEEL IN THE POOL WALL AT NO MORE THAN G" ON CENTER IN BOTH DIRECTIONS IN AREAS WHERE THE ANGLE OF REPOSE IN ENCROACHED ON OR THE POOL SHELL ENCROACHES INTO THE I TO I AREA. EXISTING STRUCTURE 2" X 4" STRINGERS PLACED AT 2 FT ON CENTER IN ALL AREAS STEEL TEX FORM W/ STRUCTURAL STEEL IN PLACE TO BE INDEPENDENTLY SUPPORTED AWAY FROM SHORING. THE POOL SHELL WALL SHALL BE CONSTRUCTED AT G" THICKNESS. 0 3 REBARS AT G" ON CENTER BOTH WAYS IN AREAS THAT EXTEND INTO THE ANGLE OF REP05E STRINGER MAY BE DRIVEN ' INTO GROUND MIN. q" OR OTHERWISE SUPPORTED TO PREVENT FROM KICKING OUT AT BASE. SNORING DETAIL IN LOCATIONS WHERE EX15TING FOUNDATION 15 THREATENED BY UNDERMINING DUE TO ADVERSE CONDITIONS AT THE TIME OF EXCAVATION SHORING MAY BE REQUIRED. CONCRETE PAVER DECK 12 3000 P51 CONCRETE W/ 2-03 REBARS RIBBON FOOTING W/ PAVER DECK SIDE WALLS tio-r 'VrLID WITWOUT EMBO�ED SEAL. 7i CONCRETE PAVER DECK 3000 F51 CONCRETE W/ 2-03 REBARS RIBBON FOOTING W/ PAVER DECK FEB 0 6 7018 FRONT WALL PARKER MYNCHENBERG, P.E. 032645 3'-6" MIN. D15TANCE LE55 THAN I ON I STRINGER TO BE SUPPORTED BY CLEATING TO SUITABLE ANCHOR DEVICE SUCH AS A 2" X 4" ATTACHED WITH ANCHOR NAILS OR TAPCON5 TO EXISTING CONCRETE LANAI OR EXISTING STRUCTURE OR ITS FOUNDATION. EXISTING STRUCTURE -USE 1/2" PLYWOOD SHEETING OR EQUIVALENT BUILDING MATERIAL TO RESTRAIN SIDE OF EXCAVATION BACKFILL BEHIND SHORING TO PREVENT UNDERMINING OF EXISTING STRUCTURE. PROVIDE WEEP HOLES AS APPROPRIATE. CONTRACTOR SHOULD ATTEMPT TO CONSTRUCT ROUGH SHELL AS RAPIDLY AS CONDITIONS WILL ALLOW. THERE 15 NO SUBSTITUTE FOR RAPIDLY BACKFILLING EXCAVATION TO PREVENT UNDERMINING OF ADJACENT STRUCTURE. PARKER MYNCI-IfENBERG 4 ASSOC. INC PROFE55IONAL ENGINEERS LANDSCAPE ARCWITEGT5 112q RIDGEWOOD AVENUE HOLLY WILL FLORIDA 32111 (386) 611-68g1 FAX (386) 611-2114 TYPICAL RES I DENTAL SW/POOL DESIGN 1=OFI SUR=SIDE POOLS 313 BEACW BOULEVARD JACKSONVILLE BEACW, FL. 32250 (qO4) 246-2666 STATE LICENSE CP0044080 THIS SIGNED AND SEALED SWEET 15 TO BE USED AS A MASTER FILE COPY . IT WILL BE USED FOR A MAXIMUM PERIOD OF ONE YEAR EXPIRING ON 12/31/18. IF THE FLORIDA BUILDING CODE 15 ALTERED OR MODIFIED BEFORE THAT DATE, TWIS DRAWING MAY BE RENDERED VOID. SHEET 4 OF 5 03 BAR AT 12 05 BAR CONTINIOUS STANDARD YARD ELEVATION 36" TURNDOWN WALL 3000 P51 PUMP MIX CONCRETE ALUMINIUM SCREEN UPRIGHT 05 BAR AT 40" ON ;ENTER WITH CELL FILLED k,JITH CONCRETE BLOCK WALL DETAIL WALL 3000 PSI PUMP MIX CONCRETE BAR AT 12" ON CENTER 04 BAR CONTINIOU5 X L c0 4ELL `f O STANDARD YARD 'I ELEVATION ALUMINIUM SCREEN UPRIGHT #5 BAR AT 40" ON CENTER WITH CELL FILLED WITH CONCRETE DECK DRAIN ,, 4" POOL DECK I 16" ; \i BLOCK WALL DETAIL WALL 3000 PSI PUMP MIX CONCRETE BAR AT 12" ON CENTER 6 FT RETAINING WALL RETAINING WALL 3000 P51 PUMP MIX CONCRETE TER 1 PARKER O -NC , NBERG .F' >z #2645 BOND BEAM WITH 1 a5 BAR DOWELS 05 REBAR 24" MAX SPACING USE 04 REBAR IF UNDER 6'-O" 05 REBAR 12" MAX SPACING USE 04 REBAR IF UNDER G' -O" < u B RETAINING WALL H A B C DOWELS TOP FOOTING (O.CJ (O.CJ 1'-4" 10" I'-8" 10 15 48" ;5 40" 2'-8" 10 I'-8" 10 i5 48" $5 40" 3'-4" 12" 2'-0" —j27 -7+5-4g- i5 —40- 4' 12" 2T--0----a7-a5 48" a5 —40- 4--S", 12" 2'-6" 12" #5 48" 05 40" 5'-4" 12" 1 3'-0" 6' 12" 3'-8" 1 12" 1 #5 48" 1 05 40" TYR RETAINING WALL DIMENSIONS PARKER MYNCPENBEzG 4 ASSOC. INC PROFESSIONAL ENGINEERS LANDSCAPE ARCHITECTS 1129 RIDGEWOOD AVENUE HOLLY HILL FLORIDA 32111 (386) 671-6891 FAX (386) 611-2114 TYPICAL RESIDENTAL SW/POOL DESIGN EOi, SUfi2E5IDE POOLS 313 BEACH BOULEVARD JACKSONVILLE BEACH, FL. 32250 (904) 246-2666 STATE LICENSE CP0044080 THIS SIGNED AND SEALED SHEET IS TO BE USED AS A MASTER FILE COPY . IT WILL BE USED FOR A MAXIMUM PERIOD OF ONE YEAR EXPIRING ON 12/31/18. IF THE FLORIDA BUILDING CODE 15 ALTERED OR MODIFIED BEFORE THAT DATE, TP15 DRAWING MAY BE RENDERED VOID. SHEET 5 OF 5 7 i 'j, "I 73Tm-, TOTAL LOT. 6,250'a Nimm SAFETY BARRIERS: FENCE &HOUSE/�V.�*D,10—*--�-— -MS III[ UP TO POOL SAFETY CODE. 7S-ET4.ACK MEASUREMENTS TAKEN FROM EDGE OF WATER TO PROPERTY LINE. REVISED 4129/2019 ADDED 530 SQ. Fl, NEW IMPERVIOUS AREA (ARTISTIC PAVER DECKING AROUND POOL). CD L16 PROPOSED LANAI/BALCONY_ XY EXISTING 2 -STY GONG EILK RESIDENCE 50.0' Ic 5' 5 THIS PLAN TO CORRELATE WITH CD PERMIT SUBMITTED BY RJ ld� ATLANTIC BUILDERS INC. OCEAN BLVD COMMUNITY DEVELOPMENT APPROVED SITE PLAN SCALE: = lj-C CID AA IDATE JJOV NU93M . . . . 7,—,] i 8 a W 4 hqflA POOL 30'X 17' W/ 3 WALL RETURNS & I PRESSURE CLEANER LINE SPA 7' DIAMETER W/ 4 THERAPY JETS MAIN DRAIN DETAIL 3'0" MINIMUM 3" TEE 3" PIPE 3" PIPE 3 X X 216." RED. BUSHING 21/2" TRUNK TO EQ. 2!N C4 r N 04 POOL/SPA WITH HEAT PUMP & GAS HEATER FILTER SCHEMATIC REVISED 4/29/2019 ADDED 530 SQ. FT NEW IMPERVIOUS AREA (ARTISTIC PAVER DECKING AROUND POOL); FINISH LANAI WITH ARTISTIC PAVERS (THIS AREA ALREADY COUNTED TOWARD IMPERVIOUS IN ORIGINAL PERMIT); ADDED DECK DRAIN; ADDED PLANTER AREAS PROPERTY LINE 0 Cl) C-4 >_ IM '50 C6 W W —1 CQ x LL W M I -- W 0 0 0 w CL Lr) < C.) p Z _j I.- < W < a. 0 z AN UNDERGROUND BONDING CONDUCTOR MADE OF A SINGLE #8 AWG BARE SOLID COPPER WIRE BURIED TO A MINIMUM DEPTH OF 4 INCHES TO 6 INCHES BELOW SUB GRADE, AND 19 INCHES TO 24 INCHES FROM INSIDE THE WALL OF A SWIMMING POOL OR SPA WILL BE USED. CN RAISED BEAM WATERFALL W1 TWO 24" WATERFALLS RAISED 12" - 24" -12" C) Florida Building Code 6''. Edition (2017) Residential Conforms to Chapter 42 2014 National Electrical Code • NO OVERHEAD ELECTRIC IN POOL AREA • NO UNDERGROUND UTILITIES IN POOL AREA • FINISH GRADE TO SLOPE AWAY FROM POOL VGB COMPLIANT MAIN DRAIN • DRAINAGE DETAIL — FINISH GRADE SLOPE AWAY FROM POOL GROUNDING & BONDING DETAIL 00 x X CO PLUMBING LINE FROM POOL :r 0 C14 3 60 " 0 0 MAIN DRAINS TO POOL 1C DEEP M Z" 17' rn 11 1 SPASIDEREMOTE 0 SPA CO POOL 30' 17' x RAISED " 11,900 GAL L 0 ONS 12 Z > M LU: SPA 7' DIA ETEER 0 OW 10, t= w III -Z Florida Building Code 6''. Edition (2017) Residential Conforms to Chapter 42 2014 National Electrical Code • NO OVERHEAD ELECTRIC IN POOL AREA • NO UNDERGROUND UTILITIES IN POOL AREA • FINISH GRADE TO SLOPE AWAY FROM POOL VGB COMPLIANT MAIN DRAIN • DRAINAGE DETAIL — FINISH GRADE SLOPE AWAY FROM POOL GROUNDING & BONDING DETAIL POOL EQUIPMENT EXISTING RESIDENCE 1 LEGEND JANDY NICHELESS LED Q --WALL RETURN 0 0 =NOVA DRAINS W =SKIMMER THERAPY JETS UMBRELLA ANCHOR BUBBLEOV. THIS PLAN TO CORRELATE TO PERMIT SUBMITTED BY RJ ATLANTIC BUILDERS INC; EXISTING GARAGE IN POOL AREA TO BE DEMOLISHED BY GC. SETBACK MEASUREMENTS TAKEN FROM EDGE OF WATER TO PROPERTY LINE. SAFETY, BARRIERS: FENCE & HOUSE / WINDOW ALARMS UP TO POOL SAFETY CODE. ALARMS TO MEET CODE UL2017. 00 w co 04 CO PLUMBING LINE FROM POOL :r C14 MAIN DRAINS TO POOL 1C M EQUIPMENT 24 C! _j 11 1 SPASIDEREMOTE - x U BRELLA ANCHOR g � > CC4, 0 OW 10, t= w III -Z W INSULATED #8 BOND WIRE IN 3-0- m0 >. C� CONDUIT FROM LIGHT NICHES SUNSHELF DEEP P t --THROUGH DECK BOX. LIGHT w UJI W GFCI PROTECTED. < '* C� CL U w > 00 UJI BUBBLER N a. W Il < (1) I----------------- - --raj--- Q M _j Z 0 ---------------- - ----------------------------- -- C14 ----------------- NEW ARTISTIC PAVER DECKING 530 SQ. ------ I I I M PLUMBING LINE FROM FT. NEW IMPERVIOUS COVERAGE ;U -->— ------POOL POOL SKIMMER TO EQUIPMENT 0 ;U I I M " 0 :I 1 1 1 > LANAI AREA FINISHED W/ M w Ijj z ARTISTIC PAVERS 1 1 1 1 w Z BARE #8 BOND WIRE ATTACHED wz I<: TO POOL STEEL _j U) Z a JUNCTION BOX Uj _ 0 Uj 0 Ix POOL EQUIPMENT EXISTING RESIDENCE 1 LEGEND JANDY NICHELESS LED Q --WALL RETURN 0 0 =NOVA DRAINS W =SKIMMER THERAPY JETS UMBRELLA ANCHOR BUBBLEOV. THIS PLAN TO CORRELATE TO PERMIT SUBMITTED BY RJ ATLANTIC BUILDERS INC; EXISTING GARAGE IN POOL AREA TO BE DEMOLISHED BY GC. SETBACK MEASUREMENTS TAKEN FROM EDGE OF WATER TO PROPERTY LINE. SAFETY, BARRIERS: FENCE & HOUSE / WINDOW ALARMS UP TO POOL SAFETY CODE. ALARMS TO MEET CODE UL2017. 00 w co 04 CO Z C14 UJI M 24 C! _j - x g � > CC4, 0 OW t= w III -Z W Ln m0 >. C� 04 ZCO w UJI W -j < '* C� CL U w > 00 UJI UJI a. W < (1) 00 M Q M _j Z 0 C14 w w 0 I- < 0 LL (1) " 0 a - M w Ijj z CO Z w Z wz I<: I- _j U) Z a im Uj _ 0 Uj 0 Ix 2 Ix Cn 4. U a 0. a w co 04 Z C14 UJI M Cal _j > Uj D J Z I Uj LU Zn Uj 0 w 0 CIO .'t w0 z < (1) 00 M Q M _j Z 0 C14 0 0 LL (1) " 0 a - M w U) CO Uj Z Uwj Ei U) ca co a im Uj _ 0 Uj 0 =1 <j ) a < C0 Cn I qj POOL 30'X 17' W/ 3 WALL RETURNS & 1 PRESSUR1 CLEANER LINE 0 -3wo 1 :11 POOL/SPA WITH HEAT PUMP & GAS HEATER FILTER SCHEMATIC THIS PLAN TO CORRELATE TO PERMIT SUBMITTED BY RJ ATLANTIC BUILDERS INC; EXISTING GARAGE IN BYPOOL AREA TO BE DEMOLISHED GC. —WWiT AN UNDERGROUND BONDING CONDUCTOR MADE OF A SINGLE #8 AWG BARE SOLID COPPER WIRE BURIED TO A MINIMUM DEPTH OF 4 INCHES TO 6 INCHES BELOW SUB GRADE, AND 18 INCHES TO 24 INCHES FROM INSIDE THEWALL OF A SWIMMING POOL OR SPA WILL BE USED. (::� RAISED BEAM WATERFALL W1 TWO 24" WATERFALLS RAISED 6" -12" - 6" O EXISTING RESIDENCE Florida Building Code VEdition (2017) Residential Conforms to Chapter 42 2014 National Electrical Code • NO OVERHEAD ELECTRIC IN POOL AREA • NO UNDERGROUND UTILITIES IN POOLAREA • FINISH GRADE TO SLOPE AWAY FROM POOL • VGB- COMPLIANT MAIN DRAIN • DRAINAGE DETAIL— FINISH GRADE SLOPE AWAY FROM POOL • GROUNDING & BONDING DETAIL PLUMBING LINE FROM POOL MAIN DRAINS TO POOL EQUIPMENT INSULATED #8 BOND WIRE IN CONDUIT FROM LIGHT NICHES THROUGH DECK BOX. LIGHT GFGIPROTECTED. I- "Al IIWQI' W&ISINKful �Jghvfi BARE #8 BOND WIRE ATTACHED TO POOL STEEL APPROVED , o PN Y, ING 0 1 L 1 DECK BY SURFSIDE. SETBACK MEASUREMENTS TAKEN FROM EDGE OF WATER TO PROPERTY LINE. SAFETY BARRIERS: FENCE & HOUSE I WINDOW ALARMS UP TO POOL SAFETY CODE. ALARMS TO MEET CODE UL2017. co co co a z C14 6- W & - - - - - :i X_ EON DEEP M w - 0� w 4-51 :E U3 M > w0 POOL PC X SPA z 11,900 GAL OW, D. RAISED 0 > w SPA 7 A E Ell ' D 0 12" a w L N go GALL U) 0< Nt 0 M it CD z 00 0 M a ca -j 0 w Z 0 Z U- 0 0� Of SPA SIDE 0 - - - - ® - REMO REMOTE Ln Z > 2 UJ w Ej rn C/) 0 ca 0 SUNSHEL 5' 10Yj U) 3101, DEEP UMBRELLA ANCHOR % BUBBLER % % N - - - - - - - - - - 4Q 'q- 111 i 111 1111 PROPOSED LANAI 111 1 BOX .JUNCTION Eld, -*-5' 1 POOL EQIJIPMENT---,, EXISTING RESIDENCE Florida Building Code VEdition (2017) Residential Conforms to Chapter 42 2014 National Electrical Code • NO OVERHEAD ELECTRIC IN POOL AREA • NO UNDERGROUND UTILITIES IN POOLAREA • FINISH GRADE TO SLOPE AWAY FROM POOL • VGB- COMPLIANT MAIN DRAIN • DRAINAGE DETAIL— FINISH GRADE SLOPE AWAY FROM POOL • GROUNDING & BONDING DETAIL PLUMBING LINE FROM POOL MAIN DRAINS TO POOL EQUIPMENT INSULATED #8 BOND WIRE IN CONDUIT FROM LIGHT NICHES THROUGH DECK BOX. LIGHT GFGIPROTECTED. I- "Al IIWQI' W&ISINKful �Jghvfi BARE #8 BOND WIRE ATTACHED TO POOL STEEL APPROVED , o PN Y, ING 0 1 L 1 DECK BY SURFSIDE. SETBACK MEASUREMENTS TAKEN FROM EDGE OF WATER TO PROPERTY LINE. SAFETY BARRIERS: FENCE & HOUSE I WINDOW ALARMS UP TO POOL SAFETY CODE. ALARMS TO MEET CODE UL2017. co co co a z C14 Cq - & :i X_ EON N M w LwwwzC'04 0� w :E ra M > z D. Z > w 0 0 a 0 z Nt M it z 00 0 M a ca 61 z Z w Z 0 Z U- 0 0� Of 0 04 z C14 co U- > z Z 06• UJ 0 z Nt M CD z 00 0 M 0 U- 0 Ln Z > 2 UJ w Ej rn C/) 0 ca 0 D U) POOL BONDING NOTES: I. EQUIPOTENTIAL BONDING OF PERIMETER SURFACES REQ' COPPER CONDUCTOR; MINIMUM 08 AWG BARE SOLID COF CONDUCTOR WHICH FOLLOWS THE CONTOUR OF THE PEF SURFACE OF THE POOL FROM 18" TO 24" FROM THE IN51C OF THE POOL AND WHICH 15 SECURED WITHIN OR UNDER PERIMETER SURFACE 4" TO G" BELOW 5UBGRADE. THE PI BONDING SHALL BE ATTACHED TO THE POOL REINFORG AT A MINIMUM OF 4 POINTS UNIFORMLY SPACED AROUND PERIMETER OF THE POOL. 2. ALL UNDERGROUND OR UNDER SLAB CONNECTIONS SHAT PER NEC 250.8. BONDING GABLES UNDER SLAB SHALL OF EXCAVATION. 3. 4. 5. 6. A SHELL BE BY LISTED MEANS PLACED AT THE BOTTOM WHEN REBAR 15 UTILIZED FOR THE CONSTRUCTION OF PLANTERS AND FOOTERS ADJACENT TO THE POOL (WITHIN 5 FT), THIS REBAR SHALL BE BONDED USING #8 AWG BARE -SOLID COPPER CONDUCTOR BY LISTED MEANS PER NEC 250.8 TO THE BONDING CONDUCTOR. S. COPPER BONDING CONDUCIOR SHALL BE BONDED TO THE POOL AND SPA REBAR AS SHOWN, 4 LOCATIONS, MINIMUM AT EACH SEPARATE BODY OF WATER, USING A #8 AWG BARE SOLID COPPER CONDUCTOR. FOR NON-CONDUCTIVE POOL SHELLS, BONDING AT 4 POINTS SHALL NOT BE REQUIRED. 9. COPPER BONDING CONDUCTOR SHALL BE BONDED TO THE EQUIPMENT GROUND OF THE POOL PUMP MOTOR ANE) OTHER ELECTRICAL COMPONENTS AS REQUIRED BY NEC 68026 (VERIFY LOCATIONS) U51NO #8 AWG BARE SOLID COPPER WIRE. 10. COPPER BONDING CONDUCTOR SHALL BE BONDED TO ALL METALLIC COMPONENTS OF THE POOL AND SPA AND THE METAL STRUCTURES, INCLUDING, BUT NOT LIMITED TO, ALL HANDRAILS, DIVING BOARDS; AND LADDER GRABRAIL5 IN THE POOL AND SPA AND AND INCLUDE ALL METAL WRING AND ALL FIXED METAL PARTS THAT ARE WITHIN 5 FT. HORIZONTALLY OF THE INSIF)E WALL OF THE POOL (5PA) AND 12 FT VERTICALLY ABOVI THE MAXIMUM WATER LEVEL OF THE POOL USING 08 AWG BARE COPPER WIRE. 11. ALL POOL AND SPA LIGHTING NICHES SHALL BE BONDED TO POOL AND SPA REBAR PER NEC 680. THE COPPER BONDING CONDUCTOR SHALL BE BONDED TO THE REBAR AT BOTH THE POOL AND THE SPA, PER NOTE 8, ABOVE, WHICH SHALL, IN TURN, PROVIDE BONDING OF THE LUMINAIRE NICHES. LOCATION OF COPPER TIC ONCONDUCTOR, BONDING JUMPERS, AND CONNECTIONS ELECTRICAL CONTRACTOR 5HALL CALL FOR THE INSPECTION OF THE BONDING OF SHOWN ARE DIAGRAMMATIC ONLL Y. CONTRACTOR SHALL FIELD ROUTE TO DETERMINE 12 EXACT LOCATION. BONDING CONDUCTOR SHALL CONFORtI TO THE SHAPE OF THE POOL THE POOL AND ITS PERIMETER SURFACES PRIOR TO COVER-UP OF THESE AREAS. WHILE FIAINTAINING SMOOTH RADIAL CURVES - NO 90° RADIUS SHALL BE PERMITTED. RESISTANCE OF THE GROUND SYSTEM SHALL NOT EXCEECh 25 OHMS IF REQUIRED, ALL GROUND RODS SHALL BE 5/8" COPPER GLAD STEEL, V LONG AND DRIVEN TO A DEPTH OF 28" BELOW FINISHED GRADE:, MINIMUM, AND WHERE USED SHALL BE BONDED USING 08 AWG BARE SOLID COPPER CONDUCTOR BY LISTED MEANS PER NEC 250.8 TO THE BONDING CONDUCTOR. SPECIAL CASES MAY INCLUDE, BUT ARE NOT LIMITED TO, VANISHING EDGE POOL5, POOLS WITH PERIMETERS OF VARYING (VERTICAL) GRADES, DIMINISHED PERIMETER SURFACES LIKE EDGE PLANTERS, STOP/RETAINING WALLS, AND ZERO -LOT LINES. IN THE5E CASES, THE BONDING CONDUCTOR SHALL BE INSTALLED IN ACCORDANCE WITH NEC 680.26, NOTE I (ABOVE), AND DIRECTION FROM THE AUTHORITY HAVING JURISDICTION (AHJ). THE ELECTRICAL CONTRACTOR SHALT_ BE RESPONSIBLE FOR COORDINATION OF THE BONDING WITH THE AHJ IN THE DETERMINATION OF IT!E�YPICAL APPLICATION OF THE NEC. LADDER, HANDRAIL, DIVING BOARD, ETC,, PUMP MOTOR METAL CONDUITS OR PIPING SYSTE POOL REINFORCING STEEL HEATER °0° IIIA I o TYPICAL POOL BONDING NOT TO SCALE BOND JUMPER NOTE 9 TYPICAL JUNCTION BOX (IF USED) NOTE5 2 AND 5N " (SPA jj -) I NOTE I 'OR NOTE 3 BOND JUMPER NOTE 8 MINIMUM 5/8" DIAMETER I\ FROM POOL REBAR OR COPPER GROUND ROD TYPICAL DRIVEN UNTIL MAXIMUM BONDING CONDUCTOR RESISTANCE VALUE OF 25 OHMS IS REACHED NOTE I (IF U5ED) BOND JUMPER NOTE 10 TYPICAL ®SWIMMING POOL LT FIXTURE TYPICAL BONDING TYPES NOTE II NOTES I, 4, NOT TO SCALE E3 TYPICAL 5 AND 8 NOTES: I. SPLICES (WELDED OR MECHANICAL) SHALL BE PERFORMED IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. TYPICAL POOL BONDING PLAN NOT TO SCALE POOL LIGHT NICHE CONTROL PANEL(5) TIC SCHEMATIC NOTES: 1. THE EQUIPOTENTIAL BONDING OF ALL CONDUCTIVE POOL 51-IELLS, PERIMETER SURFACES, METALLIC COMPONENTS, UNDERWATER LIGHTING, METAL FITTINGS, ELECTRICAL EQUIPMENT, AND METAL WIREWAY5/CONDUIT5 SHALL BE IN ACCORDANCEi WITH NEC 680.26. OR, AS ACCEPTED BY THE AUTHORITY HAVING JURISDICTION (AHJ). BONDING LEGEND • BOND CONNECTION, PER NEC 250.8 o PARALLEL TAP CONNECTION, PER NEC 2508 UNDERGROUND BONDING CONDUCTOR, 08 AWG (MINIMUM) NOT V LID WITH EMB O SEV tSJEAL h -FE8 Ti, PARKER MYNCHENBERG 4 ASSOC. INC PROFESSIONAL ENGINEERS LANDSCAPE ARCHITECTS 1129 RIDGEWOOD AVENUE HOLLY HILL FLORIDA 32111 (386) 611-6891 FAX (386) 611-2114 TYPICAL RESIDENTAL SW/POOL ?' DESIGN EOR SURFSIDE POOLS ,3 Ad 313 BEACH BOULEVARD JACKSONVILLE BEACH, FL. 32250 (904) 246-2666 STATE LICENSE OPCO44080 PARKER MYNCHENBERG. P.E. `#32645 ; THIS SIGNED AND SEALED SHEET 15 TO BE USED AS A MA5TER FILE COPY. IT WILL BE USED FOR A MAXIMUM PERIOD OF ONE YEAR EXPIRING ON 12/31/18, IF THE FLORIDA BUILDING CODE 15 ALTERED OR MODIFIED BEFORE THAT DATE, THIS DRAWING MAY BE RENDERED VOID. SHEET 3 OF 5 `J0. OCEAN BLVD S TE PLAN SCALE:°= l' -O" Rul 05. °�SY BS list HIN c •�e:og�s�-;�6� s Ist♦w" BY AA HEcnn EY: (DATE: 1 12S/I:t lJBF.RENGRI I DWG NO: S1 8 u�� 1 I ' irl ��I ' I PROPOSED 2 -STY GARAGE iF 0' I 1 I �I !p 0 o p iI PROPOSED j I I I,ANAI/BAICONY � 1 1 I 1 1 1 0 1 LC I i I I � EXISTING 2 -STY I - CONC EILK j I I, I i "' RESIDENCE 1 I I 1 I I I `J0. OCEAN BLVD S TE PLAN SCALE:°= l' -O" Rul 05. °�SY BS list HIN c •�e:og�s�-;�6� s Ist♦w" BY AA HEcnn EY: (DATE: 1 12S/I:t lJBF.RENGRI I DWG NO: S1 8 u�� 4" DECK 03 BAR AT 12" ON CENTER LONG FLAT TURN DOWN FOOTER DETAIL TYPE BRICK PAVER POOL DECK PAVER DECK TURNDOWN DETAIL 04 BAR AT 12" ON :ENTER a 1-03 BAR VERTICALLY J' ' ENTER ® 36" ON CENTER- 1-05 1-03 BAR CONTINUOUS 9" PAVER DECK TURNDOWN DETAIL 04 BAR AT 12" ON :ENTER 3-1/2" TYP ALL SLABS FOOTING (2) 03 REBAR CONT. Y I FT IN 6 OR STEEPER 1 FT IN TO I FT IN 3) 03 REBAR CONT. MOTERATE SLOPE FOOTING STEEP SLOPE FOOTING TYPE 2 TYPE 2 BAR AT 12" ON CENTER 3AK INUOUS 2N sr 4 MIN 04 BAR AT 12" ON CENTER �1 i�\ 04 BAR AT 12" ON CENTER << 32" 4 FT RETAINING WALL RETAINING WALL 3000 PSI PUMP MIX CONCRETE 24" FT RETAINING WALL AINING WALL 3000 P51 PUMP MIX CONCRETE BAR AT 12" ON CENTER 5LA5-FOOTING DETAIL5 2500 MIN. GUNITE MAY BE SUB5ITIUTED FOR 3000 PSI CONCRETE USE 6X6 10/10 HW OR FIBER MESH CURE FOR ONE WEEK BEFORE INSTALLING ANCHORS. GONGRETE PAVER DECK z � 12" 3000 P51 CONCRETE W/ 2-03 REBARS RIBBON FOOTING W/ PAVER DECK 5 FT RETAINING WALL RETAINING WALL 3000 P51 PUMP MIX CONCRETE THE POOL CONTRACTOR SHALL PLACE ALL STEEL IN THE POOL WALL AT NO MORE THAN G" ON CENTER IN BOTH DIRECTIONS IN AREAS WHERE THE ANGLE OF REPOSE IN ENCROACHED ON OR THE POOL SHELL ENCROAGHES INTO THE I TO I AREA. EXISTING STRUCTURE 2" X 4" STRINGERS PLACED AT 2 FT ON CENTER IN ALL AREAS STEEL TEX FORM W/ STRUCTURAL STEEL IN PLACE TO BE INDEPENDENTLY SUPPORTED AWAY FROM SNORING. THE POOL SHELL WALL SHALL BE — CONSTRUCTED AT G" THICKNESS. 0 3 REBARS AT 6" ON CENTER BOTH WAYS IN AREAS THAT EXTEND INTO THE ANGLE OF REPOSE STRINGER MAY BE DRIVEN INTO GROUND MIN. 9" OR OTHERWISE SUPPORTED TO PREVENT FROM KICKING OUT AT BASE. SNORING DETAIL IN LOCATIONS WHERE EXISTING FOUNDATION IS THREATENED BY UNDERMINING DUE TO ADVERSE CONDITIONS AT THE TIME OF EXCAVATION SHORING MAY BE REQUIRED. — CONCRETE PAVER DECK ON .;4: 1 12„ 3000 P51 CONCRETE W/ 2-03 REBARS RIBBON FOOTING W PAVER DECK SIDE WALLS NOT `,XLID WITHOUT EMBOSSED SEAL. CONCRETE PAVER DECK N 12" i.) 3000 P51 CONCRETE W/ 2-03 REBARS RIBBON FOOTING W/ FAVER DECK FEB 0 6 2018 FRONT WALL 3'-6" MIN. DISTANCE LESS THAN 1 ON I STRINGER TO BE SUPPORTED BY CLEATING TO SUITABLE ANCHOR DEVICE SUCH AS A 2" X 4" ATTACHED WITH ANCWOR NAILS OR TAPCONS TO EXISTING CONCRETE LANAI OR EXISTING STRUCTURE OR ITS FOUNDATION. EXISTING STRUCTURE RWA USE 1/2" PLYWOOD SHEETING OR EQUIVALENT BUILDING MATERIAL TO RESTRAIN SIDE OF EXCAVATION BACKFILL BEHIND SHORING TO PREVENT UNDERMINING OF EXISTING STRUCTURE. PROVIDE WEEP HOLE5 AS APPROPRIATE. CONTRACTOR SHOULD ATTEMPT TO CONSTRUCT ROUGH SHELL AS RAPIDLY AS CONDITIONS WILL ALLOW. THERE IS NO SUBSTITUTE FOR RAPIDLY BACKFILLING EXCAVATION TO PREVENT UNDERMINING OF ADJACENT STRUCTURE. PARKER MYNCNENBERG 4 A5500. INC PROFE-55IONAL ENGINEERS LANDSCAPE ARCHITECTS 1129 RIDGEWOOD AVENUE HOLLY WILL FLORIDA 32111 (386) 611-6891 FAX (386) 611-2114 TYPICAL RE5I DENTAL SW/POOL DESIGN FOR SURf=SIDE POOLS 313 BEACH BOULEVARD JACKSONVILLE BEACH, FL. 32250 (904) 246-2666 STATE LICENSE CPC044080 THIS SIGNED AND SEALED SHEET 15 TO BE USED AS A MASTER FILE COPY . IT WILL BE USED FOR A MAXIMUM PERIOD OF ONE YEAR EXPIRING ON 12/31/18. IF THE FLORIDA BUILDING CODE 15 ALTERED OR MODIFIED BEFORE THAT DATE, THIS DRAWING MAY BE RENDERED VOID. PARKER MYNCHENBERG, P.E. 032645 11 SHEET 4 OF 5 ffl 3-1/2" TYP ALL SLABS FOOTING (2) 03 REBAR CONT. Y I FT IN 6 OR STEEPER 1 FT IN TO I FT IN 3) 03 REBAR CONT. MOTERATE SLOPE FOOTING STEEP SLOPE FOOTING TYPE 2 TYPE 2 BAR AT 12" ON CENTER 3AK INUOUS 2N sr 4 MIN 04 BAR AT 12" ON CENTER �1 i�\ 04 BAR AT 12" ON CENTER << 32" 4 FT RETAINING WALL RETAINING WALL 3000 PSI PUMP MIX CONCRETE 24" FT RETAINING WALL AINING WALL 3000 P51 PUMP MIX CONCRETE BAR AT 12" ON CENTER 5LA5-FOOTING DETAIL5 2500 MIN. GUNITE MAY BE SUB5ITIUTED FOR 3000 PSI CONCRETE USE 6X6 10/10 HW OR FIBER MESH CURE FOR ONE WEEK BEFORE INSTALLING ANCHORS. GONGRETE PAVER DECK z � 12" 3000 P51 CONCRETE W/ 2-03 REBARS RIBBON FOOTING W/ PAVER DECK 5 FT RETAINING WALL RETAINING WALL 3000 P51 PUMP MIX CONCRETE THE POOL CONTRACTOR SHALL PLACE ALL STEEL IN THE POOL WALL AT NO MORE THAN G" ON CENTER IN BOTH DIRECTIONS IN AREAS WHERE THE ANGLE OF REPOSE IN ENCROACHED ON OR THE POOL SHELL ENCROAGHES INTO THE I TO I AREA. EXISTING STRUCTURE 2" X 4" STRINGERS PLACED AT 2 FT ON CENTER IN ALL AREAS STEEL TEX FORM W/ STRUCTURAL STEEL IN PLACE TO BE INDEPENDENTLY SUPPORTED AWAY FROM SNORING. THE POOL SHELL WALL SHALL BE — CONSTRUCTED AT G" THICKNESS. 0 3 REBARS AT 6" ON CENTER BOTH WAYS IN AREAS THAT EXTEND INTO THE ANGLE OF REPOSE STRINGER MAY BE DRIVEN INTO GROUND MIN. 9" OR OTHERWISE SUPPORTED TO PREVENT FROM KICKING OUT AT BASE. SNORING DETAIL IN LOCATIONS WHERE EXISTING FOUNDATION IS THREATENED BY UNDERMINING DUE TO ADVERSE CONDITIONS AT THE TIME OF EXCAVATION SHORING MAY BE REQUIRED. — CONCRETE PAVER DECK ON .;4: 1 12„ 3000 P51 CONCRETE W/ 2-03 REBARS RIBBON FOOTING W PAVER DECK SIDE WALLS NOT `,XLID WITHOUT EMBOSSED SEAL. CONCRETE PAVER DECK N 12" i.) 3000 P51 CONCRETE W/ 2-03 REBARS RIBBON FOOTING W/ FAVER DECK FEB 0 6 2018 FRONT WALL 3'-6" MIN. DISTANCE LESS THAN 1 ON I STRINGER TO BE SUPPORTED BY CLEATING TO SUITABLE ANCHOR DEVICE SUCH AS A 2" X 4" ATTACHED WITH ANCWOR NAILS OR TAPCONS TO EXISTING CONCRETE LANAI OR EXISTING STRUCTURE OR ITS FOUNDATION. EXISTING STRUCTURE RWA USE 1/2" PLYWOOD SHEETING OR EQUIVALENT BUILDING MATERIAL TO RESTRAIN SIDE OF EXCAVATION BACKFILL BEHIND SHORING TO PREVENT UNDERMINING OF EXISTING STRUCTURE. PROVIDE WEEP HOLE5 AS APPROPRIATE. CONTRACTOR SHOULD ATTEMPT TO CONSTRUCT ROUGH SHELL AS RAPIDLY AS CONDITIONS WILL ALLOW. THERE IS NO SUBSTITUTE FOR RAPIDLY BACKFILLING EXCAVATION TO PREVENT UNDERMINING OF ADJACENT STRUCTURE. PARKER MYNCNENBERG 4 A5500. INC PROFE-55IONAL ENGINEERS LANDSCAPE ARCHITECTS 1129 RIDGEWOOD AVENUE HOLLY WILL FLORIDA 32111 (386) 611-6891 FAX (386) 611-2114 TYPICAL RE5I DENTAL SW/POOL DESIGN FOR SURf=SIDE POOLS 313 BEACH BOULEVARD JACKSONVILLE BEACH, FL. 32250 (904) 246-2666 STATE LICENSE CPC044080 THIS SIGNED AND SEALED SHEET 15 TO BE USED AS A MASTER FILE COPY . IT WILL BE USED FOR A MAXIMUM PERIOD OF ONE YEAR EXPIRING ON 12/31/18. IF THE FLORIDA BUILDING CODE 15 ALTERED OR MODIFIED BEFORE THAT DATE, THIS DRAWING MAY BE RENDERED VOID. PARKER MYNCHENBERG, P.E. 032645 11 SHEET 4 OF 5 1�2 I aFIG L PAVER MUD SET --I' ` OL DECK 03 BAR AT 12" ON CENTER X �< in in \ 36" TURNDOWN WALL 3000 F51 FUMP MIX ALUMINIUM SCREEN UPRIGHT 04 BAR GONTINIOU5 OJ ON POOL SHELL `r O STANDARD YARD N ELEVATION ALUMINIUM 50REEI4 UPRIGHT 05 BAR GONTINIOU5 8 Al X Q L i m O H O �D xx alln �O �— #5 BAR AT 40" ON CENTER ya; WITH CELL FILLED WITH CONCRETE Xw DECK DRAIN STANDARD YARD W 4" POOL DECK ELEVATION BAR AT 12" ON CENTER BLOCK WALL DETAIL WALL 3000 PSI PUMP MIX CONCRETE 05 BAR AT 40" ON CENTER WITH CELL FILLED WITH CONCRETE DECK DRAIN / 4" POOL DECK f t t BLOCK WALL DETAIL WALL 3000 PSI PUMP I`IIX CONCRETE BAR AT 12" ON CENTER 6 FT RETAINING WALL RETAINING WALL 3000 PSI PUMP MIX CONCRETE ITER N PARKER o' FEB 1YNG1 ENBERG .PSE: #2645: R s `a BOND BEAM WITH 1 #5 BAR DOWELS 05 REBAR 24" MAX SPACING USE #4 REBAR IF UNDER 6'-O" f-05 RE15AR 12" MAX USE 044 REBAR F UN DER G'—O" RETAINING WALL N A B G DOWELS TOP FOOTING 1'-4" 10" I'-8" 10" 15 48" 05 40" 2'-8" 10" 1'-8" 10" 15 /I 05 40" V-4" 12" 2'-0" 12" #5 48" B 40" 4' RETAINING WALL N A B G DOWELS TOP FOOTING 1'-4" 10" I'-8" 10" 15 48" 05 40" 2'-8" 10" 1'-8" 10" 15 48" 05 40" V-4" 12" 2'-0" 12" #5 48" #5 40" 4' 12" 2'-0" 12" #5 48" 05 40" 4'-8" 12" 2'-6" 12" #5 48" 1 #5 40" 5'-4" 12 3'-O" 12" #5 48" 1#5 40to 6' '- 1 V-8" 12" 1 #5 48" 1 #5 40" TYF'. RETAINING WALL DIMENSIONS PARKER MYNOPENSERG 4 ASSOC. INC PROFESSIONAL ENGINEERS LANDSCAPE ARCHITECTS 112q RIDGEWOOD AVENUE HOLLY HILL FLORIDA 32111 (386) 611-68gl FAX (386) 611-2114 TYPICAL RESIDENTAL SW (FOOL DESIGN FOR SURFSIDE POOLS 313 BEACH BOULEVARD JACKSONVILLE BEACH, FL. 32250 (qO4) 246-2666 5TATE LICENSE CFC044080 THIS 51GNED AND 5EALED SPEET 15 TO BE U5ED A5 A MA5TER FILE COPY . IT WILL BE USED FOR A MAXIMUM PERIOD OF ONE YEAR EXPIRING ON 12/31/18, IF THE FLORIDA BUILDING CODE 15 ALTERED OR MODIFIED BEFORE THAT DATE, THIS DRAWING MAY BE RENDERED VOID. 5HEET 5 OF 5 0 ji WA 192"1 POOL 30'X 17' W/ 3 WALL RETURNS & I PRESSURE CLEANER LINE SPA 7' DIAMETER W/ 4 THERAPY JETS 3'0" MINIM�� 3" TEE 3" PIPE Y PIPE 3'! X T/2" RED. BUSHING t ---Lr" TRUNK _j TO EQ. POOL/SPA WITH HEAT PUMP & GAS HEATER FILTER SCHEMATIC THIS PLAN TO CORRELATE TO PERMIT SUBMITTED BY RJ ATLANTIC BUILDERS INC; EXISTING GARAGE IN POOL AREA TO BE DEMOLISHED BY GC. [UU1111:24AC111111111111►I AA UNDERGROUND BONDING CONDUCTOR MADE OF A SINGLE #8 AWG BARE SOLID COPPER WIRE BURIED TO A MINIMUM DEPTH OF 4 INCHES TO 6 INCHES BELOW SUB GRADE, AND 18 INCHES TO 24 INCHES FROM INSIDE THE WALL OF A SWIMMING POOL OR SPA WILL BE USED. 0) RAISED BEAM WATERFALL W/ TWO 24" WATERFALLS RAISED 6" -12" - 6" C? EXISTING RESIDENCE Florida Building Code V, Edition (2017) Residential Conforms to Chapter 42 2014 National Electrical Code NO OVERHEAD ELECTRIC IN POOL AREA • NO UNDERGROUND UTILITIES IN POOL AREA • FINISH GRADE TO SLOPE AWAY FROM POOL • VGB COMPLIANT MAIN DRAIN • DRAINAGE DETAIL — FINISH GRADE SLOPE AWAY FROM POOL • GROUNDING & BONDING DETAIL PLUMBING LINE FROM POOL MAIN DRAINS TO POOL EQUIPMENT INSULATED #8 BOND WIRE IN CONDUIT FROM LIGHT NICHES —THROUGH DECK BOX. LIGHT GFCIPROTECTED, POOL SKIMMER TO POOL EQUIPMENT BARE #8 BOND WIRE ATTACHED TO POOL STEEL COPING ONLY. NO DECK BY SURFSIDE. 11141 1 z 19 _- f -AT -01 12, 2 Lvi I : r A: ill 120A: I ivi I: 10 1 M rn a 0 z I a -.101 j I a Illevzol ITAT F_ K TO P KO P F_ A..' LVF1 F. SAFETY BARRIERS: FENCE & HOUSE / WINDOW ALARMS UP TO POOL SAFETY CODE. 00 00 co LU C14 o 6'0" C14 r -- LU DEEP - 17' 04 W CD CO POOL 30' 17' 2 SPA C,4 w w 11,900 GAL ONS RAISED 12" w w SPA VDIA ETER z 53650 W Z CO GALL NS cl) z 0 < z n w w LU w 4 0 0 1 0 1 1% W LU SPA SIDE I LU r- — — — — — REMOTE w 0 0 w w SUNSHEL 5' 10w--41 ca 15 0 3'0" Cn U.1 DEEP • Z UMBRELLA z z w ANCHOR Cn w BUBBLER 0 w w w 0 (0 L--------- - — — — — _---- III 1 PROPOSED LANAIIII 1 III i JUNCTION BOX POOL EQUIPMENT_ EXISTING RESIDENCE Florida Building Code V, Edition (2017) Residential Conforms to Chapter 42 2014 National Electrical Code NO OVERHEAD ELECTRIC IN POOL AREA • NO UNDERGROUND UTILITIES IN POOL AREA • FINISH GRADE TO SLOPE AWAY FROM POOL • VGB COMPLIANT MAIN DRAIN • DRAINAGE DETAIL — FINISH GRADE SLOPE AWAY FROM POOL • GROUNDING & BONDING DETAIL PLUMBING LINE FROM POOL MAIN DRAINS TO POOL EQUIPMENT INSULATED #8 BOND WIRE IN CONDUIT FROM LIGHT NICHES —THROUGH DECK BOX. LIGHT GFCIPROTECTED, POOL SKIMMER TO POOL EQUIPMENT BARE #8 BOND WIRE ATTACHED TO POOL STEEL COPING ONLY. NO DECK BY SURFSIDE. 11141 1 z 19 _- f -AT -01 12, 2 Lvi I : r A: ill 120A: I ivi I: 10 1 M rn a 0 z I a -.101 j I a Illevzol ITAT F_ K TO P KO P F_ A..' LVF1 F. SAFETY BARRIERS: FENCE & HOUSE / WINDOW ALARMS UP TO POOL SAFETY CODE. w 00 00 co LU C14 o z C14 r -- LU C14 - 04 C-4 CO (0 w w 0 > w w Uj z C� Z CO Uj >_ z CO Od < z n w w LU w (L 0 L) 0 z W LU W LU 0 w 0 0 w w Cn ca 15 0 LU Cn U.1 • Z W z z w z Cn w 0 w w w 0 (0 w LU C14 z C14 LU LU LL > LLI Z CO Uj LU z CO Od < Ui 2 0 w 0 z 0 < z M 0 0 0 LL Cn 0 LU Cn U.1 0. Z W 0 w Cn w C) 0 (0 -61 8 11 IMPERVIOUS CALCULATIONS:50.0 r--------------- TOTAL LOT: 6,250 SQ IFT I r I frog°g6 5��eas.:o���� HOUSE/PATIO: 1,845 SQ FT j ?�; j5$I$€if5 GARAGE/STEPS: PROPOSED oal 405 SQ FT j 2-STY o ��I 1 8g.o`5o3. §�.Jj =a��ael$4 DRIVEWAY: 859 SQ FT GARAGE r a ¢ �:ea fiE TOTAL IMPERVIOUS: 3,109 SQ FT ISR: 50% j 5' 19" ----- THIS PLAN TO CORRELATE WITH I PROPOSED I PERMIT SUBMITTED BY RJ SAFETY BARRIERS: FENCE & HOUSE/WINDOW ALARMS j LANAI/BALCONY , ,51511 ATLANTIC BUILDERS INC. UP TO POOL SAFETY CODE. i POOL,,'�► II EQUIPMENT ALARMS TO MEET CODE UL2017. a Ln ji j Ln N II I I N j POOL / SPA COPING ONLY, NO DECKING BY SURFSIDE. EXISTING 2-STY I GONG BLK j RESIDENCE � I � I COMMUNITY TAKEN j I w MEASUREMENTS MEASUREENTS FROM EDGE OF WATER TO I' I APPRo C PROPERTY LINE. I I D o l0.]i w c., - - -----------� SCALE: 1/20" = 1' 50.0 SITE PLAN SCALE: d. - l'-O" I n:�� � " n/?x/Ix ------------------------- 9 oe mumlim EBENER OCEAN BLVD 71095 --i Dwo NO: S1 8 OF �EE,_ JOB SPECIFIC PIPE SIZING, TOTAL DYNAMIC HEAD CALCULATIONS AND EQUIPMENT SPECIFICATIONS AND DOCUMENTATION ARE TO BE PROVIDED BY l'HE POOL CONTRACTOR FOR EAGN PROJECT. TWE POOL CONTRACTOR -MUST USE THE MAXIMUM FLOW CAPA-,ITY OF TOE SELECTED PUMP AND PROVIDE HYDRAULIG CALCULATIONS FOR TOW TO DETERMINE PROPER PUMP AND PIPING SIZING. TWE MANUFACTURER'S EQUIPMENT SPECIFICATIONS AND OTHER DOGUMENITATION FOR PUMPS, FILTERS, NEATER EQUIPMENT AND MAIN DRAINS AND COVERS ARE TO BE SUBMITTED FOR REVIEW AND DOCUMENTATION FOR SIZING THE CIRCULATION SYSTEM. RECIRCULATION GHLORINATC POOL FILTER THE MAIN DRAIN PIPE INVERT NEEDS TO BE 15 TIMES THE DIAMETER DOWN FROM THE TOP OF THE MAIN DRAIN GRATE TO THE TOP OF THE MAIN DRAIN PIPE, IF THE PIPE COMES IN VERTICAL TO THE MAIN DRAIN BOX. IF THE MAIN DRAIN PIPE COMES INTO THE MAIN DRAIN BOX HORIZONTALLY, THE COVER FROM THE TOP OF THE GRATE TO THE TOP OF THE MAIN DRAIN PIPE NEEDS TO BE 15 TIMES THE DIA. OF THE MAIN DRAIN PIPE. 1-1/2 TIMES THE DIA. 1-1/2 TIMES THE DIA. MAIN MAIN DRAIN DRAIN RETURN LINE r— _ __ __ ___ _ ------------ I � , F (OPTION WALL RETURNS) I1 n II n II 11 II RETURN INLET (OPTION WALL RETURNS) I RETURN INLET-' 11 UNDERWATER LIGHT (OPTION WALL RETL N DRAIN SI�GTION --------r MAIN DRAINS MEET THE VIRGINIA GRAEME BAKER POOL AND SPA SAFETY ACT. SUCTION 1 1 1 1 i __-- 111 LI — li1 .—J1 JJr{{ ___ �i________________ r =_____-- — 111 --- —•- �� V II W I I j 11 1j Q ly 11 (ISI I i FLOOR RETURN iii i � 3 REQ'D. III II II 12ETUKN III II —RETURN INLET INLET �RE1 1 SKIMMER I I I I n 11 l i SKIT IMER I I I y------------ - ----------------------- RETURN LINE (OPTION WALL RETURN5) LOW PROFILE JUNCTION BOX— UL APPROVED UNDERWATER LIGHT POOL SHELL 3000 P51 PUMP MIX CONCRETE PNEUMATICALLY APPLIED. 6"-1" IN VERTICAL WALLS (TTP) 6'-8" IN COVES AND FLOOR5 (TYP) 2500 MIN. GUNITE MAY BE 5UB51TIUTED FOR 3000 P51 CONCRETE I'-6" 4.0' SWIM mim OUT DEEP END FLOOR ANO WALL REINFORCEMEN7 TO SLOPE 5REAK- 05 BAR ® 12" ON CENT 03 BAR ® G" ON GENT WATER LINE DECK OVER POUR OR BRICK COPING c0 2—e BARS--/ ' 03 BAR CONT. DONT. IN 6" OF WATER IN 5" THICK BOND 811XB" BOND LINE TILES BEAM BEAM 1 Zig RETURN INLET 45)zi I I wl INLET WALL RETURNS) T` FICAL SWIMMING POOL #3 BAR5 GRADE 40,12" O.G. VERTICAL AND ERAMIC TILE HORIZONTAL (TYP) WATER LINE 1/2" QUARTZ FINISH `—MAIN DRAIN W/ RELIEF PLUG OR 2" \ WYOR05TATIC RELIEF VALVE, IF REQ -D. ROCKBED EACH WAY < 8.0' DEEP EACH WAY > 8.0' DEEP AND OVER. POOL SECTION 4" i»OI 03 BAR5 12" ON CENTER EACH WAY (GRADE 40) ALTERNATE SEAM FINISH DETAIL PAVER DECKING OR 4" THICK CONCRETE DECK W/ FIBER MIX 2500 P51 OR WIRE MESH GENERAL NOTES: I. POOL 15 TO BE BUILT TO COMPLY WITH FLORIDA, COUNTY AND CITY BUILDING CODES. 2. ALL METAL PARTS WITHIN 5 FT. WILL BE GROUNDED AS PER NATIONAL ELECTRIC GODE AND AS REQUIRED BY LOCAL INSPECTOR. B. FILTRATION SYSTEM WILL HAVE SUFFICIENT CAPACITY TO PROVIDE A COMPLETE TURNOVER OF POOL WATER IN (12) TWELVE HOURS OR LESS. 4. POOL CONSTRUCTION TO BE THE SAME REGARDLESS OF 51ZE AND SHAPE. IF FILL IS REQUIRED FOR 2 FT. TO 4 FT. OF WALL HEIGHT THEN WALLS HAVE TO BE REINFORCED WITH ADDITIONAL STEEL (8" O.G. BOTH WAYS) AND/ OR EXTRA WALL THICKNESS (8" TO 10') S. ALL PVC PIPE WILL BE SCHEDULE 40. 6. ALL METAL FIXTURES AND POOL LIGHTS TO BE BONDED TO POOL STEEL AND GROUND WIRE. 1. POOL ALARMS DO NOT NEED TO BE HARDWIRED S. SOIL CONDITIONS AT POOL LOCATION ARE ASSUMED TO BE ADEQUATE FOR A SINGLE FAMILY DWELLING. 9. TERMITE CONTROL WILL BE APPLIED UNDER ALL POOL DECKS. 10, ALL PUMPS AND FILTERS WILL BE ANCHORED TO A CONCRETE PAD WITH TAP CON ANCHORS. 11. ALL POOL AND SPA SUCTION INLETS SHALL BR PROVIDED WITH A COVER THAT HAS BEEN TESTED AND ACCEPTED BY A RECOGNIZED TESTING FACILITY AND COMPLY WITH A.N.S.IJAS. M.E. A112.19, 8M, "SUCTION FITTINGS FOR USE IN SWIMMING POOLS, SPAS, HOT TUBS, AND WHIRLPOOLS BATHTUB APPLIANCES" 12. THE POOL DESIGN WILL MEET CHAPTERS 42 AND 45 OF THE 2011 FLORIDA BUILDING CODE 6TH EDITION. 13. RESIDENTIAL POOLS MUST COMPLY WITH CHAPTER5 42 AND 45 OF THE 2011 FLORIDA BUILDING CODE GTP EDITION. 14. POOL CONSTRUCTION WILL MEET 2014 NATIONAL ELECTRIC CODE. SEE 68026 (5)(2)(b) FOR PERIMETER BONDING U51NO AT LEAST ONE() 08 AWG BARE 50LID COPPER CONDUCTOR. 15. FOR RE51DE14TIAL POOLS UP TO A WATER DEPTH OF 8'-0" 03 REBAR 12" O.C.B.W. OVER 8'-0' SPECIAL ENGINEERING 15 REQUIRED AND 15 NOT A PART OF THIS DRAWING SPECIFICATIONS. WALL THICKNESS SHALL PROVIDE CODE COVER OVER REINFORCING. FOR OVER 8'-O" A SPECIAL DESIGN WILL BE REQUIRED. 16, RESIDENTIAL POOLS SHALL COMPLY WITH THE AN51/APSP/IGC-5 2011 FOR RESIDENTIAL INGROUND POOL5, AN51/APSP/ICG-3 2014 FOR PERMANENTLY INSTALLED RESIDENTIAL SPAS, AND ANSI/APSP/ICG-1 2013 FOR SUCTION ENTRAPMENT AVOIDANCE STANDARDS. AND AN5I/APSP/ICG-15A 2013 STANDARD FOR RESIDENTIAL SWIMMING POOL AND SPA ENERGY EFFICIENCY Il. DO NOT USE OR OPERATE POOL OR SPA IF THE SUCTION FITTING 15 MISSING, BROKEN, OR LOOSE. 18. IF THE SUCTION INLET SYSTEM, SUCH AS AN AUTOMATIC CLEANING SYSTEM, 15 A VACUUM GLEANER SYSTEM WHICH HAS A SINGLE SUCTION INLET, OR MULTIPLE SUCTIONS INLETS WHICH CAN BE ISOLATED BY VALVES, THEN EACH SUCTION INLET SHALL PROTECT AGAINST USER ENTRAPMENT BY EITHER AN APPROVED ANTI -VORTEX COVER, 12" X 12" GRATE OR LARGER, OR OTHER APPROVED MEANS. COMPACTED 501L UNDER PARKER MYNCNENBERG 4 A5500. INC CONCRETE DECK PROFESSIONAL ENGINEERS LANDSCAPE ARCHITECTS I129 RIDGEWOOD AVENUE HOLLY HILL FLORIDA 32111 (386) 611-6891 FAX (386) 611-2114 NOT VALID WITHOUT EMBOSSED SEAL. t a c amt LB1 0 62,Oj_8. PARKER MYN HENBERG, P,Ei' #32645 TYPICAL RE5IDENTAL 5W/POOL DESIGN FOR SURES 1 DE POOLS 313 BEACH BOULEVARD JACKSONVILLE BEACH, FL. 32250 (904) 246-2666 STATE LICENSE OF0044080 THIS SIGNED AND SEALED SHEET 15 TO BE USED AS A MASTER FILE COPY . IT WILL BE USED FOR A MAXIMUM PERIOD OF ONE YEAR EXPIRING ON 12/31/18. IF THE FLORIDA BUILDING CODE IS ALTERED OR MODIFIED BEFORE THAT DATE, TH15 DRAWING MAY BE RENDERED VOID. SHEET I OF 5 K=CAKC.ULAI fUN Cd!1WVNI a►.r_W. POOL FILTER THERAPY JET RETURN LINE �� 11 11 11 I! MAIN DRAIN (SUCTION) -------------------- :::7LZZ7/7:: l' II ii 11 II 11 I i I I 11 11 I 11 II RETURN LINE - ------------ J II II 11 11 II IL ------------------------------JI L--------------------------------- MAIN DRAINS MEET THE VIRGINIA GRAEME BAKER POOL AND 5PA SAFETY ACT. (SECOND MAIN DRAIN MAY BE ON SIDE WALL) TYPICAL SPA POOL - 2 MAIN DRAINS ON FLOOR POOL SHELL 3000 P51 CONCRETE PNEUMATICALLY APPLIED. 6" IN VERTICAL WALLS (TYP) 6" IN COVES AND FLOORS (TYP) 2500 MIN. GUNITE MAY BE 5UBSITIUTED FOR 3000 P51 CONCRETE 1/2" QUARTZ FINISH UL APPROVED UNDERWATER LIGHT COMPACTED SOIL UNDER GONCETE DECK N MAIN DRAIN SUCTION LINE -- ------�-�-- MAIN DRAIN W/ RELIEF PLUG OR 2" HYDROSTATIC RELIEF VALVE, IF REQV. 5ECTI ON UNDERWATER LIGHT 3/4" BULLN05E TILE OPTIONAL ON EDGE OF STEP. PAVER DECKING OR 4" THICK GONGRETE DECK W/ FIBERMIX 3000 P51 WATER LINE 6"X6" CERAMIC TILE LOW PROFILE JUNCTION BOX MIN. THE MAIN DRAIN PIPE INVERT NEEDS TO BE 1.5 TIMES THE DIAMETER DOWN FROM THE TOP OF THE MAIN DRAIN GRATE TO THE TOP OF THE MAIN DRAIN PIPE, IF THE PIPE COMES IN VERTICAL TO THE MAIN DRAIN BOX. IF THE MAIN DRAIN PIPE COMES INTO THE MAIN DRAIN BOX HORIZONTALLY, THE COVER FROM THE TOP OF THE GRATE TO THE TOP OF THE MAIN DRAIN PIPE NEEDS TO BE 1.5 TIMES THE DIA. OF THE MAIN DRAIN PIPE. 1-1/2 TIMES THE DIA. _— 1-1/2 TIMES THE DIA. MA—IN MAIN DRAIN DRAIN GAP TILE/ BRICK/ OR CANTILEVER WITH WATERLINE TILE 2-03 REBAR CONTINUOUS STEEL REINFORCED CONCRETE — DECK AND TILE DETAIL DEXTRA K3 BARS NOT VALID WITHOUT coNrlNUous EMBOSSED SEAL.' pa. #3 BARS 12" O.G. i�Ta i y p 0 c 00 VERTICAL AND HORIZONTAL HORIZONTAL (TYP) yf y t >oa t. NCA4 9 *00 0 (GRADE 40) - p00 .00 'lam 000 ROGKBED fib'. aP J �018 PARKER MYNCHENBERG, P.E. #32645 AGRLYIC FINISH PARKER MYNCHEENBERG 4 ASSOC. INC PROFESSIONAL ENGINEERS LANDSCAPE ARCHITECTS 1129 RIDGEWOOD AVENUE HOLLY HILL FLORIDA 32117 (386) 617-6891 FAX (386) 6-11-2114 TYPICAL RESIDENTAL SW/POOL DESIGN FOR SURFSIDE POOLS 313 BEACH BOULEVARD' JACKSONVILLE BEACH, FL. 32250 (904) 246-2666 STATE LICENSE GP0044080 THIS SIGNED AND SEALED SHEET 15 TO BE USED AS A MASTER FILE COPY . IT WILL BE USED FOR A MAXIMUM PERIOD OF ONE YEAR EXPIRING ON 12/31/18. IF THE FLORIDA BUILDING CODE IS ALTERED OR MODIFIED BEFORE THAT DATE, THIS DRAWING MAY BE RENDERED VOID. SHEET 2 OF 5 Simplified Total Dynamic Head Calculation 18_. Friction loss in suction pipe Pool/Spa Combo @ Determine Maximum System flow Rate: 117 gpm ( from pipe flow/friction loss chart) = 0.09 Friction loss in return pipe 2" Swimming Pool Info: 373 3 to 6 to N/A _ Volume: 11900 gallons ( Surface Area 38 (Shallow) 3 (Deep) (Shallow) Volume: 550 gallons Spa Info: 45 x Ft. of head per one foot of pipe 0.16 = ( Surface Area (Depth) 18.1 20.4 TDH in piping 11.25 Other Loss in TDH 12450 Total Volume Preferred Turnover Time in Hours : 6 x 60 min. = 3610 - Main Drain 2.34 (Hours) (turnover time in minutes) 1 Heater loss in TDH (from Maxium Pool Flow Rate: 12450 divided by 360 35 gpm 48 = 83 gpm (gallons) (turnover time in minutes) (flow rate pool) (feature flow rate) Spa Jets (#) 4 x 13 gpm per jet = 52 flow rate (# of jets) oet flow) 4 Floor System 0.00 A&A Quik Clean System NONE x 0 gpm Cleaner Head 0 flow rate NONE x 0 gpm Cleaner Head 0 flow rate NONE x 0 gpm Cleaner Head 0 flow rate (# of heads) (head flow) 0 Total Floor Heads flow rate 22.9 83 4- Highest required flov✓ rate between "Maximum Pool Flow Maximum Pool System Flow Rate: 31.9 Rate" and "Spa .lets" and "Quick Clean System" Determine Pipe Sizes: 16.1 18.4 20.6 1 PoollSpa: Branch piping to be: 3" inch to keep velocity @ 6 fps.Max.at : 136 gpm. Maximum System Flow Rate Trunk piping to be : 2.5" inch to keep velocity @ 8 fps.Max.at: 117 gpm. Maximum System Flow Rate Return piping to be 2" inch to keep velocity @ 10 fps.Max.at : 103 gpm. Maximum System Flow Rate Determine Simplfied TDH (POOL); Jandy Pro Series VS FloPro Series Pump VS-FHP1.0 Perform- Curves 43 W 18_. Friction loss in suction pipe 2.5" @ 8 fps inch pipe per one foot @ 117 gpm ( from pipe flow/friction loss chart) = 0.09 Friction loss in return pipe 2" @ 10 fps inch pipe per one foot @ 103 gpm ( from pipe flow/friction loss chart) = 0.16 Length of suction pipe 45 x Ft. of head per one foot of pipe 0.09 = 4.05 TDH in piping Length of pressure pipe 45 x Ft. of head per one foot of pipe 0.16 = 7.20 TDH in piping 90 18.1 20.4 TDH in piping 11.25 Other Loss in TDH ft. of head # Filter loss in TDH (fromfilter data sheet) - Main Drain 2.34 2.34 20.4 1 Heater loss in TDH (from heater data sheet) 0.00 (from heater data sheet) Returns 3/4" 3.30 3.30 9.2 1 5.64 Therapy Jet 0.00 27.72 22.8 0 Pool Total Dynamic Head (TDH) 20 4 Floor System 0.00 19.65 13.8 0 18.3 20.5 `Total 5.64 TT 27.3 29.6 5 11.6 13.8 8 18.3 20.6 22.9 25.1 27.4 29.6 31.9 F 13.8 16.1 18.4 20.6 1 22.9 25.2 1 27.4 29.7 31.9 34.2 3 18.4 20.7 23.0 25.2 27.5 1 29.7 32.0 34.3 36.5 18.5 20.7 23.0 25.3 27.5 29.8 32.0 34.3 36.6 ° 1 i� g 20.8 23.1 25.3 27.6 29.8 32.1 34.4 36.6 38.9 41.1 i 10 23.1 25.4 27.6 28.9 32.1 34.4 36.7 38.9 41.2 43.4 25.4 27.7 29.9 32.2 3a R 39.0 41.2 43.5 45.8 27.7 30.0 32.2 1 34.5 36.8 3 41.3 1 43.5 45.8 48.1 t ' 13 30.0 32.3 34.6 1 36.8 1 39.1 41.3 43.6 45.9 1 48.1 50.4 `. 14 32.3 34.6 36.9 1 39.1 41.4 43.6 1 45.9 48.2 50.4 52.7 1 1,5 34.7 36.9 39.2 41.4 43.7 46.0 48.2 50.5 52.7 55.0 i- 1 3 37.0 39.2 :i 40 43.7 46.0 48.3 50.5 52.8 55.0 57.3 1 f 39.3 41.5 43.8 46.1 48.3 50.6 52.8 55.1 57.4 59.6 17 w 41.6 43.8 46.1 48.4 50.6 52.9 2 57.4 59.7 61.9 W 1 `9 43.9 46.2 48.4 50.7 52.9 55.2 57.5 59.7 62.0 S 3D_ M 23 46.2 48.5 50.7 53.0 55.2 _._ 59.8 62.0 .......-... 66.5 _..... 1 .. .-_._.- 53.0 55.3 _ 59.8 _ _.. 13 a 66.6 68.9 = 22 50.8 53.1 55.3 57.6 59.9 62.1 64.4 66.6 68.9 71.2 23 53.1 55.4 57.7 59.9 62.2 64.4 66.7 69.0 71.2 73.5 ITIRP111 'I 24 55.4 S7.7 60.0 62.2 64.5 66.7 69.0 71.3 73.5 75.8 25 57.8 60.0 62.3 64.5 66.8 69.1 71.3 73.6 75.8 78.1 [ ; 26 60.1 62.3 64.6 66.8 69.1 71.4 73.6 75.9 78.1 80.4 '. 2T 62.4 64.6 66.9 69.2 ;r R 75.9 78.2 80.5 82.7 23 64.7 66.9 69.2 71.5 73.7 76.0 78.2 80.5 82.8 85.0 29 67.0 69.3 71.5 73.8 76.0 78.3 80.6 82.8 85.1 87.3 3 30 69.3 71.6 73.8 76.1 78.3 80.6 82.9 85.1 87.4 89.6 0 10 20 30 90 60 W 71W90 1W 110 120 130 190 150 100 170 130 190 2W 1. Rata, 04- P.r Mbm , (GPM) Distance from nearest edge of pool to pump in feet = 45 Total Head in Feet Conversion Chart-,.,, Inches Mercury (Vacuum Gauge) 4_.._----- 8. $11-�Q 12-1 94__-16 18_. Friction loss in suction pipe 2.5" @ 8 fps inch pipe per one foot @ 117 gpm ( from pipe flow/friction loss chart) = 0.09 Friction loss in return pipe 2" @ 10 fps inch pipe per one foot @ 103 gpm ( from pipe flow/friction loss chart) = 0.16 Length of suction pipe 45 x Ft. of head per one foot of pipe 0.09 = 4.05 TDH in piping Length of pressure pipe 45 x Ft. of head per one foot of pipe 0.16 = 7.20 TDH in piping 15.9 18.1 20.4 TDH in piping 11.25 Other Loss in TDH ft. of head # Filter loss in TDH (fromfilter data sheet) 3.60 ( from filter data sheet) Main Drain 2.34 2.34 20.4 1 Heater loss in TDH (from heater data sheet) 0.00 (from heater data sheet) Returns 3/4" 3.30 3.30 9.2 1 'Total all other loss 5.64 Therapy Jet 0.00 27.72 22.8 0 Pool Total Dynamic Head (TDH) 20 4 Floor System 0.00 19.65 13.8 0 18.3 20.5 `Total 5.64 25.1 27.3 29.6 5 Pool Pump: JandV FloPro VS -FHP 1 hp 83 Gallons Per Minute 20 Total Dynamic Head (TDH) Pool Filter: Jandu CS150 Cartridge Heater: JXi400P Jandy Pro Series (LP Ig as Pool Nova 7-314" Pool Drain Main Drain: Floor Installation @ 150 gpm ma;ic. flow - _.. 47--r, Total Head in Feet Conversion Chart-,.,, Inches Mercury (Vacuum Gauge) 4_.._----- 8. $11-�Q 12-1 94__-16 18_. 0.0 2.3 4.5 6.8 9.0 11.3 13.6 15.8 18.1 20.3 1 2.3 4.6 6.8 9.1 11.4 13.6 15.9 18.1 20.4 22.7 2 4.6 6.9 9.1 11.4 13.7 15.9 18.2 20.4 22.7 25.0 1 6.9 9.2 11.5 13.7 16.0 18.2 20.5 22.8 25.0 27.3 4 9.2 11.5 13.8 160 18.3 20.5 22.8 25.1 27.3 29.6 5 11.6 13.8 16.1 1 18.3 20.6 22.9 25.1 27.4 29.6 31.9 F 13.8 16.1 18.4 20.6 1 22.9 25.2 1 27.4 29.7 31.9 34.2 16.2 18.4 20.7 23.0 25.2 27.5 1 29.7 32.0 34.3 36.5 18.5 20.7 23.0 25.3 27.5 29.8 32.0 34.3 36.6 38.8 g 20.8 23.1 25.3 27.6 29.8 32.1 34.4 36.6 38.9 41.1 i 10 23.1 25.4 27.6 28.9 32.1 34.4 36.7 38.9 41.2 43.4 25.4 27.7 29.9 32.2 34.5 36.7 39.0 41.2 43.5 45.8 27.7 30.0 32.2 1 34.5 36.8 39.0 41.3 1 43.5 45.8 48.1 t ' 13 30.0 32.3 34.6 1 36.8 1 39.1 41.3 43.6 45.9 1 48.1 50.4 `. 14 32.3 34.6 36.9 1 39.1 41.4 43.6 1 45.9 48.2 50.4 52.7 1 1,5 34.7 36.9 39.2 41.4 43.7 46.0 48.2 50.5 52.7 55.0 i- 1 3 37.0 39.2 41.5 43.7 46.0 48.3 50.5 52.8 55.0 57.3 1 f 39.3 41.5 43.8 46.1 48.3 50.6 52.8 55.1 57.4 59.6 13 41.6 43.8 46.1 48.4 50.6 52.9 55.1 57.4 59.7 61.9 W 1 `9 43.9 46.2 48.4 50.7 52.9 55.2 57.5 59.7 62.0 64.2 { 23 46.2 48.5 50.7 53.0 55.2 57.5 59.8 62.0 64.3 66.5 I[ 1 48.5 50.8 53.0 55.3 57.6 59.8 62.1 64.3 66.6 68.9 = 22 50.8 53.1 55.3 57.6 59.9 62.1 64.4 66.6 68.9 71.2 23 53.1 55.4 57.7 59.9 62.2 64.4 66.7 69.0 71.2 73.5 'I 24 55.4 S7.7 60.0 62.2 64.5 66.7 69.0 71.3 73.5 75.8 25 57.8 60.0 62.3 64.5 66.8 69.1 71.3 73.6 75.8 78.1 [ ; 26 60.1 62.3 64.6 66.8 69.1 71.4 73.6 75.9 78.1 80.4 '. 2T 62.4 64.6 66.9 69.2 71.4 73.7 75.9 78.2 80.5 82.7 23 64.7 66.9 69.2 71.5 73.7 76.0 78.2 80.5 82.8 85.0 29 67.0 69.3 71.5 73.8 76.0 78.3 80.6 82.8 85.1 87.3 3 30 69.3 71.6 73.8 76.1 78.3 80.6 82.9 85.1 87.4 89.6 '. 31 71.6 73.9 76.1 78.4 80.7 82.9 85.2 $7.4 89.7 92.0 32 73.9 76.2 78.4 80.7 83.0 85.2 87.5 89.7 92.0 94.3 33 76.2 78.5 80.8 83.0 85.3 87.5 89.8 92.1 94.3 96.6 34 78.5 80.8 83.1 85.3 $7.6 89.8 92.1 94.4 96.6 .98.9 1 36 80.9 83.1 85.4 1 87.6 1 89.9 1 92.2 94.4 96.7 98.9 101.2 1 Design Head LOSS (ft head) ci IJV'. 60 so 120 Flown (tate (gpm) 3 Design Pressure 2 DfO? (gel) Tom'* G$150 1 05200 t --- CS250 CS100 i 0 Robert & Laura Ebener 1330 Ocean Blvd. Atlantic Beach 32233 12/20/2018