Loading...
510 ROYAL PALMS DR ROW19-0001 RELOCATE PERMIT RIGHT OF WAY PERMIT PERMIT NUMBER ` CITY OF ATLANTIC BEACH ROW19-0001 Vr 800 SEMINOLE ROAD ISSUED: 1/16/2019 ATLANTIC BEACH. FL 32233 EXPIRES: 4/16/2019 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL • ' K MUST CONFORM TO THE CURRENT 6TH EDITION1 OF • ' DA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts,state agencies, or federal agencies. • : • • •N: VALUE OF • 510 ROYAL PALMS DR RIGHT OF WAY SINGLE OR TWO relocate JEA pole $0.00 FAMILY RIGHT OF WAY TYPE OF • ZONING: :D • CONSTRUCTION:- GROUP: 171514 0000 ROYAL PALMS UNIT 02A3.00 COMPANY: ADDRESS: Jacksonville Electric 21 W. Church Street Jackonville FL 32202 Authority k OWNER: ADDRESS: ' OGIN JACK F 6101 RAINTREE RD JACKSONVILLE FL 32277 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF . . • Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. 1 PUBLIC WORKS ON SITE RUNOFF INFORMATIONAL Notes: All runoff must remain on-site during construction. Issued Date: 1/16/2019 1 of 2 RIGHT OF WAY PERMIT PERMIT NUMBER CITY OF ATLANTIC BEACH ROW19-0001 800 SEMINOLE ROAD ISSUED: 1/16/2019 ATLANTIC BEACH. FL 32233 EXPIRES: 4/16/2019 2 PUBLIC WORKS ROLL OFF CONTAINER INFORMATIONAL Notes: Roll off container company must be on City approved list(Advanced Disposal,Realco Recycling,Shapells,Inc.,Republic Services,Donovan Dumpsters, Phillips Containers,JDog/Dennis Junk Removal). Container cannot be placed on City right-of-way. 3 PUBLIC WORKS RIGHT OF WAY RESTORATION INFORMATIONAL Notes: Full right-of-way restoration,including sod,is required. 4 PUBLIC UTILITIES UNDERGROUND WATER SEWER UTILITIES INFORMATIONAL Notes: Avoid damage to underground water and sewer utilities. Verify vertical and horizontal location of utilities. Hand dig if necessary. If field coordination is needed,call 247-5878. 5 PUBLIC UTILITIES UTILITY MAP INFORMATIONAL Notes: See attached Utility Map. s 77 DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT TOTAL: Issued Date: 1/16/2019 2 of 2 City of Atlantic Beach APPLICATION NUMBER �s S� Building Department (To be assigned by the Building Department.) 1 800 Seminole Road Q Atlantic Beach, Florida 32233-5445 —coo/ Phone(904)247-5826 Fax(904)247-5845 f E-mail: building-dept@coab.us Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: l 0paDepartment review required Yes No Building Applicant: lc- A Planning &Zoning t � Tree Administrator .Q,l l Project: `� CCT Q ,� � � �(�t� Public Works Public tilities Public a e y Fire Services Review flee$ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING _�� C� Reviewed by: e: TREE ADMIN. Second Review: ❑Approved as revis []Denied. []Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. []Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 City of Atlantic Beach nECEIVE APPLICATION NUMBER Building Department (To be assigned by the Building Department.) s� 800 Seminole Road JAN Q r,� —Cool Atlantic Beach, Florida 32233-,04 4 2019 h�L Phone(904)247-5826 - Fax(9042 7-5845 f I CUM � ' E-mail: building-dept@coab.us [iY, Date routed: `( y City web-site: hftp://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 5 ( C) (.( � pa ht�Vi Department review required Yes No A Building A Applicant: Ic Planning &Zoning 1 l Tree Administrator Project: '� �1 l c C JL ��`.� Public Works Public tilities Public ee y Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receiptof Permit Verified By Date Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [,]Approved. ❑Denied. []Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed b r Date: -' TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. [—]Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 RIGHT-OF-WAY/EASEMENT PERMIT APPLICATION "ALL INFORMATION ` City of Atlantic Beach HIGHLIGHTED IN GRAY IS 800 Seminole Road,Atlantic Beach, FL 32233 REQUIRED. c. PERMITTEE RESPONSIBLE FOR NOTIFYING 811 AND OBTAINING UTILITY LOCATES Job Address S/(� t�Dt�� l J%/vyt t py— Permit Number Contractor Information Company SGn Qualifying Agent Address 2-1 �✓�51 (/Lt yr,Y City )Ax State_Zip 3 zza Z Phone Email State Certification/Registration# Architect Phone Email Engineer s t ✓"T h Phone_ GGS 77 Lj 3 Email Workers Compensation Insurer ✓ OR Exempt❑Expiration Date • Permittee declares that prior to filing this application they have ascertained the location of all existing utilities,both aerial and underground and the accurate locations are shown on the sketches. • Whenever necessary for the construction,repair,improvement,maintenance,safe and efficient operation,alteration or relocation of all,or any portion of said street or easement as determined by the Public Works Director,any or all said poles, wires,pipes,cables or other facilities and appurtenances authorized hereunder,shall be immediately removed from said street or easement or reset or relocated hereon as required by the Public Works Director and at the expense of the Permittee unless reimbursement is authorized. • All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of i ►'' (Project Superintendent) with(Company Name) - Phone (20 rf g • All materials and equipment shall be subject to inspection by the Public Works Director. • All city property shall be restored to its original condition as far as practical,in keeping with City specifications and the manner satisfactory to the City. • A sketch of plans covering details of this installation,as well as a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the City right-of-way are to be included with this application. • The permittee shall commence actual construction in good faith within days. If the beginning date is more than 60 days from date of permit approval then permittee must review the permit with the Public Works Director to make sure no changes have occurred in the area that would affect the permitted construction. • It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right, title and interest in the land to be entered upon and used by the holder,and the holder will,at all times,assume all risk of and indemnify,defend and save harmless the City of Atlantic Beach from and against any and all loss,damage and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. • The I' or c)or shall be notified 24 hours prior to starting work and again immediately/upon completion. Date Permittee(signed in presence of otary Public) STATE OF FLORIDA,COUNTY OF DUVAL The foregoing instrument was acknowledged this day of 20_ by_ who personally appeared before me and (printed name of Permittee) acknowledged that he/she signed the instrument voluntarily for the purpose expressed in it. [ I Personally Known Signature of Notary Public,State of Florida [ I Produced Identification(Type) H:\Applications&Forms\Word Documents\201801001 Right-of-Way Easement Permit Application.docx Revision Date:10/1/18 ENGINEERING DESIGN ORACLE PERMIT MAXIMO DATE REL PROJECT#: 36888 N.O.: 8005212 WO#: 30382332 CONST:01111119 CIR. TREE TRIMMING SUB-STA: NEPTUNE BEACH N.O.: 563 REO'D:YES CELL ENGINEER: Robert Simpson N.O.: NIA ZIP CODE: N/A CUSTOMER/ SVC PHONE LOCATION: 506 ROYAL PALMS DR./50/3C RELOCATE 563 CENTER: SSSC N.O.:665-7793 ® 0 775 STA 1, P# 506 ROYAL PALMS DR./ e N 0 RELOCATE 50/3C POLE AS CLOSE TO THE PROPERTY LINE AS POSSIABLE. ( 546 00 0 2T aT RELOCATE TRANS TO STA 2. j gOT Ln �D N 1 STA 2, P# 526 ROYAL PALMS DR./ _ RE, FIN DR INSTALL 50KVA. ------ _ ***** TREE TRIMM REQUIRED O 1 P o 1 2T 1/0 a t � 1 � STA 2 i 780 77 785 775 '1 526 ® � 50C ( i{ � 1/OT 1/OT♦ Q Ni O O , � 506 t __ �LO DR �---_ o w 436 ) o ® 4 zT T 50A t� tQ 0 10 w STA 1 790 t � 4W ( � � o ! � N OD 486 U) o 1 SOC 0 �, all -P { ►� -� 00 CUE Reports Estimate Number:36888 506 ROYAL PALMS DR./POLE Estimate Type:GD Contract:089-16-HM OH FY 19 RELOCATE Estimate Version: By: SIMPRB MWO#/Task:30388026 Required Date: Oracle Project#:8005212 Estimated On: 01/11/2019 Cost Estimate Materials JEA Contractor 1.New Material Cost(w/sales tax) $1,975.14 $1,975.14 2.Transformer Cost(w/sales tax) $1,391.61 $1,391.61 3.Returned Material Salvage Value $0.00 $0.00 Labor 4.Crew Time $2,115.92 $4,239.68 5.Extraordinary Costs $0.00 $0.00 JEA Overhead 6.Fringe Benefits(54.56%of lines 4&7) $1,309.83 $311.35 7.Engineering Costs(Variable%of line 4) $284.80 $570.66 8.Project Equipment Costs(40%of total equipment costs) $1,254.76 $0.00 9.Material Handling(8.30%of lines 1 &2) $279.44 $279.44 10.Inspection(6.84%of line 4) $0.00 $289.99 11.Total Cost of Project $8,611.49 $9,057.87 12.Work Order Estimate(Line 11 minus line 8,9,&10) $7,077.30 $8,778.43 13.Billable Equipment Depreciation(60%of total equipment costs) $1,882.14 $0.00 14.Billing Estimate(Including Transformer Cost)(Lines 11+13+(58.71%of 4&7)) $11,903.09 $9,392.90 15.Billing Estimate(W/O Transformer Cost)(Lines 11 +13+(58.71%of 4&7)-Line 2) $10,511.49 $8,001.30 Time Estimate Crew Hours Total Manhours 16.97 67.86 --------------------------------------------------------------------------------------------------------------------------------- CUE Reports Estimate Number:36888 506 ROYAL PALMS DR.[POLE Estimate Type:GD Contract:089-16-HM OH FY19 RELOCATE Estimate Version: By: SIMPRB MWO#[Task:30388026 Required Date: Oracle Project#:8005212 Estimated On: 01/11/2019 CU Detail lwAlm, Station: 01 0. -O. ,- BuOd Transfer Remain in Place Remove DA5F-5`2 1 DC1 F-5'636 1 F9`80T 1 G3C*2 1 GY3-A"5 1 I.BAYSW003 1 P.50/3C 1 RUBUP 8 S1 1 S20ES`4/0-1/0 2 S4'4/0 1 S9`2 2 S9"4/0 4 SEVP 2 BANK10 1 BAYONET 1 CLAMP 3 CUTOUT 1 DOWN3/8 1 FULLGRD 1 NUMBER 1 P.50/3C 1 PIN 3 POLECON 2 PRIINS 4 RUBDOWN 8 SMWEDGE 2 STANDOFF 3 SWITCH 1 Station: • ROAYL PALMS DR. Build Transfer Remain in Place Remove DGAC'50 1 . JVI CUE Reports Estimate Number:36888 506 ROYAL PALMS DR./POLE Estimate Type:GD Contract:089-16-HM OH FY19 RELOCATE Estimate Version: By: SIMPRB MWO#/Task:30388026 Required Date: Oracle Project#:8005212 Estimated On: 01/11/2019 G 1 C*2 1 RUBUP 8 S20ES*4/0-1/0 3 S4*2/0 1 S9*1/0 4 S9*2/0 2 RUBDOWN 8 SMWEDGE 3 CUE Reports Estimate Number:36888 506 ROYAL PALMS DR./POLE Estimate Type:GD Contract:089-16-HM OH FY19 RELOCATE Estimate Version: By: SIMPRB MWO#!Task:30388026 Required Date: Oracle Project#:8005212 Estimated On: 01/11/2019 Material Summary Item Quantity Item Number Item Description 1 ADCM1001 ADHESIVE, POLE TAG, 2.8 FL. OZ.TUBE TRANSLUCENT COLOR, EXPIRATION DATE MUST APPEAR ON EACH INDIVIDUAL ITEM 1 ARRL1003 ARRESTER, LIGHTNING, 18 KV, DISTRIBUTION CLASS AND RISER POLE (MOV)WITHOUT MOUNTING BRACKET, 152/26.4Y NOMINAL VOLTAGE 1 BAYSWO03 BAYONET, SHIELD WIRE, CORNER,40"LENGTH 1 BKTAC001 BRACKET, ARRESTER&CUTOUT, SINGLE MOUNT 1 BKTAC009 BRACKET, ARRESTER AND CUTOUT, FIBERGLASS WITH RAYCHEM MATERIAL OVER ROD TYPE: SINGLE PHASE 3 BKTFS001 BRACKET, FIBERGLASS STANDOFF, 2" FIBERGLASS ROD, 18" STANDOFF TO INS BASE ROD COVERED WITH RAYCHEM HEAT- SHRINK MATERIAL, DUCTILE IRON FITTINGS 3 BOLDA015 BOLT, 3/4"X 14", DOUBLE ARMING, GALV.WITH 4 SQUARE NUTS ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 1 BOLDA016 BOLT, 3/4"X 16", DOUBLE ARMING, GALV.WITH 4 SQUARE NUTS ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 3 BOLMS020 BOLT, MACHINE, 5/8"X 14", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 50 EACH) 5 BOLMS035 BOLT, MACHINE, 3/4"X 12", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 2 BOLMS036 BOLT, MACHINE, 3/4"X 14", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 1 BOLMS037 BOLT, MACHINE, 3/4"X 16", SQUARE HEAD GALVANIZED STEEL, W/SQUARE NUT ATTACHED, (MUST BE SHIPPED IN STD. BOX QUANTITIES OF 25 EACH) 12 CAIRH010 CABLE, NO.4 SOFT DRAWN SOLID COPPER, COVERED TAP WIRE WITH LAYER OF FLEXIBLE, BLACK, THERMOPLASTIC ELASTOMER INSULATION (SHIPPED IN 200 FOOT HAND COIL) (20,000 FT MIN ORDER) 1 CLAGRO01 CLAMP, GROUND ROD, 5/8"-4SOL "HAMMERLOCK" 5 CLASR003 CLAMP, STRAIN RELIEF WEDGE MESSENGER, SIZE:#6-2/0 2 CLASS004 CLAMP, STRAIGHT STRAIN,ALUMINUM, 50004,4-3/0 ALUM 1 CLASS006 CLAMP, STRAIGHT STRAIN,ALUMINUM, 10000#3/0-556 ALUM (STD PKG 15 EA) 1 CLATGO01 CLAMP,TRANSFORMER TANK GROUND, 'BRONZE"6 SOL- 1 STR. 1 CLEIN001 CLEVIS, INSULATED, GALVANIZED, INSULATOR NOT INCLUDED, 3- 1/4"CLEVIS OPENING 10 CNNCP002 CONNECTOR,#2, 6-2 MAIN, 2-1/0 TAP,ALUMINUM COMPRESSION, PARALLEL TAP, 12 CNNCP004 CONNECTOR,#4, 1/0-2/0 MAIN, 1/0-3/0 TAP COMPRESSION, PARALLEL TAP,ALUMINUM, CUE Reports Estimate Number:36888 506 ROYAL PALMS DRJ POLE Estimate Type:GD Contract:089-16-HM OH FY19 RELOCATE Estimate Version: By: SIMPRB MWO#/Task:30388026 Required Date: Oracle Project#:8005212 Estimated On: 01/11/2019 10 CNNCP006 CONNECTOR, #6, 1/0-2/0 MAIN, 3/0-4/0 TAP COMPRESSION, PARALLEL TAP, ALUMINUM, 8 CNNCP007 CONNECTOR, #7, 3/0-4/0 MAIN, 3/0-4/0 TAP COMPRESSION, PARALLEL TAP,ALUMINUM, 5 CNNCP008 CONNECTOR, #5, 6-2 MAIN, 4/0 TAP, COMPRESSION, PARALLEL TAP, ALUMINUM, 2 CNNGRO02 COUPLING, GROUND ROD, "THREADLESS"REMARKS: FOR THREADLESS GROUND RODS 3 CNNTS009 CONNECTOR, CONTAMINATED ENVIRONMENT,TRANSFORMER SECONDARY SET SCREW TYPE WITH INHIBITOR, 1/2" STUD, RANGE.- 12-350, ANGE:12-350, 6-PORTS. 11 CNNVG003 CONNECTOR, 6-2 SOL/10-2 SOL, VISE GRIP PARALLEL, BRONZE 51 COBC0028 CONDUCTOR, #4 SOLID, SOFT DRAWN, BARE COPPER, 200', 25#,ON PLASTIC REEL, 4"X 11.5"W/2" HOLE 2 COBTWO06 CONDUCTOR, #2 SOLID (AAC)TIE WIRE EC GRADE ALL-ALUMINUM 25#COIL 44 COVIC002 COVER, "D" DIE, INSULATING, 2-1/2" 1 CUTOT004 CUTOUT, 100-AMP, OPEN FUSED, 15/26 KV, (48 EA PER PALLET) 1 CUTOT006 CUTOUT, CONTAMINATED ENVIRONMENT, 26"LEAKAGE DISTANCE TO GROUND, 100A, 27 KV, 170 KV BIL (54 EA PER PALLET) 1 FUSOH010 FUSE, OVERHEAD DISTRIBUTION, 23" MINIMUM LENGTH, 80T. 1 FUSOH024 FUSE, OVERHEAD DISTRIBUTION, 3.1 AMP, TRANSFORMER. 1 GUAAN006 GUARD,ANIMAL, FOR FUSE CUTOUTS, JEA UNIVERSAL DESIGN MADE FROM SILICONE RUBBER 1 GUAGWO02 GUARD, "YELLOW", GUY WIRE, 1/4"TO 1/2"8', POLYETHYLENE, USED ON ALL 3/8"AND 7/16"GUY STRANDS (DISTRIBUTION) 1 GUYAT008 GUY HOOK, COMBINATION, MALLEABLE OR DUCTILE IRON, HOT DIP GALV. 13/16" MOUNTING HOLE, 20,000 LB MIN. ULT. STRENGTH. FOR WOOD OR CONCRETE POLES 2 GUYGRO01 GRIP, GUY, 3/8", 26", GALVANIZED 50 GUYST005 STRAND, GUY, 3/8" DIA, 7 PER STRAND, GALVANIZED STEEL, CLASS "B" GALV. OR BEZINOL IS ACCEPTABLE (500'COIL) 1 INSC0001 INSULATOR, COMPOSITE,SILICON-RUBBER,LEAKAGE DISTANCE MIN. 36", MIN. 25KV, 15000#STRENGTH, DEADEND 1 INSFE002 INSULATOR, FIBERGLASS EXTENSION REMARKS: FIBERGLASS W/PROTECTIVE COATING CLEVIS-EYE, 12 INCH FIBERGLASS LENGTH, 15,000 LB ULTIMATE STRENGTH USED FOR EXTENDING POLYMER DEADEND INS. FROM POLE 1 INSGB002 INSULATOR, STRAIN, GUY BREAKER, 21,000#RATED, 60" ROD LENGTH, FIBERGLASS FOR USE ON JEA'S DISTRIBUTION SYSTEM ONLY 1 INSST002 INSULATOR, SPOOL TYPE, WHITE OR GREY, RATED STRENGTH OF 3000# 2 INSS0002 INSULATOR, SUSPENSION,4", CLASS 52-9 NEMA STRENGTH 10000#, GALV. FITTINGS 3 INSVP001 INSULATOR, VERTICAL POST, TIE TOP 35-KV, 3/4"STUD TAP STANDARD PACKAGING IS NOT TO EXCEED THREE UNITS OR 72 POUNDS. 1 NUTEY003 NUT, EYE, 3/4", HOT DIPPED GALVANIZED CUE Reports Estimate Number:36888 506 ROYAL PALMS DR./POLE Estimate Type:GD Contract:089-16-HM OH FY19 RELOCATE Estimate Version: By: SIMPRB MWO#/Task:30388026 Required Date: Oracle Project#:8005212 Estimated On: 01/11/2019 3 NUTSL003 NUT, LOCK, SQUARE, 5/8" HOLE SIZE, HOT DIPPED GALVANIZED 5 NUTSL004 NUT, LOCK, SQUARE,3/4"BOLT SIZE, HOT DIPPED GALVANIZED 3 NUTSQ004 NUT, SQUARE 3/4" HOT DIPPED GALVANIZED 1 POLC0006 POLE, CONCRETE 50'TYPE 3, (T/L 7 EACH) 4 RODGRO03 ROD, GROUND, THREADLESS, 5/8"X 8', SHIP ON OPEN FLATBED ONLY! 2 SLEAL002 SLEEVE, ORANGE TO ORANGE NEUTRAL 4-4 ALUMINUM TRIPLEX NEUTRAL SPLICING 4 SLEAL003 SLEEVE, RED TO RED NEUTRAL 2-2 ALUMINUM TRIPLEX NEUTRAL SPLICING 2 SLEFT004 SLEEVE, 2/0, FULL-TENSION ALUMINUM COMPRESSION TYPE 4 SLEFT006 SLEEVE,4/0 7-STR AAAC, FULL-TENSION ALUMINUM, COMPRESSION TYPE 3 STUL1001 STUD, LINE POST, DIA.SHANK-3/4", SHANK LENGTH- 1-3/4", GALVANIZED STEEL W/NUTS AND WASHERS; 3/4" HEAD SIZE 1 TAGH0007 ALUMINUM VERTICAL TAG HOLDER FOR ADHESIVE BACK CHARACTERS((NOT FOR"SLIDE IN"CHARACTERS)). 19.5" HIGH X 2" WIDE WITH 3-1/8"NAIL HOLES @ THE TOP AND THE BOTTOM. (PKG. OF 50 EACH) 3 TIEPRO05 TIE, PREFORMED LINE, 636 AAC, 28"MIN. LENGTH, "F" NECK, SIDE TIE .856"-.968" COND. RANGE, **INS ITEM** 1 TRAC0002 TRANSFORMER, 50 KVA, 14760/25565Y VOLT PRIMARY, 120/240 VOLT SECONDARY, SINGLE PHASE, CONTAMINATED ENVIRONMENT-JEA SPECIFICATION REQUIRED 2 WASRD004 WASHER, ROUND, 5/8" BOLT SIZE X 1 3/4" DIAMETER, GALVANIZED, 650 EA P/BOX) 29 WASRD005 WASHER, ROUND, 3/4"BOLT SIZE X 2" DIAMETER, GALVANIZED,*** 500 EACH PER BOX*** 12 WASSF003 WASHER, SQUARE FLAT, 3"SQ X 1/4", 5/8"X 3/4"BOLT SIZE, GALVANIZED 10 WASSP002 WASHER, SPRING, 3/4"BOLT SIZE, DOUBLE COIL HELICAL TYPE, GALVANIZED (EXTRA HEAVY DUTY) . r�. CUE Reports Estimate Number:36888 506 ROYAL PALMS DR./POLE Estimate Type:GD Contract:089-16-HM OH FY19 RELOCATE Estimate Version: By: SIMPRB MWO#/Task:30388026 Required Date: Oracle Project#:8005212 Estimated On: 01/11/2019 CU Summary CU Name Quantity Description DA5F-5'2 1 DEADEND UNSHIELDED DC1F-5'636 1 TANGENT TO 10 DEGREE ANGLE UNSHIELDED, CONTAMINATED DGAC`50 1 TRANS; CI, 26AKV 120/240 50KVA F9`80T 1 S/P TAP FUSE FROM CROSSARM/POLETOP PIN G1C*2 1 CONCRETE POLE-EQUIPMENT GROUND G3C"2 1 CONCRETE POLE-NON-EQUIPMENT GROUND GY3-A`5 1 3/8" DOWNGUY WITHOUT ANCHOR P.50/3C 1 50 FT. TYPE III CONCRETE POLE RUBUP 16 LINE RUBBER INSTALLATION, PER SECT. S1 1 OPEN WIRE SPOOL-NEUTRAL S20ES'4/0-1/0 5 SECONDARY CONNECTION AT POLE S4'2/0 1 SECONDARY DEADEND S4'4/0 1 SECONDARY DEADEND S9'1/0 4 SECONDARY SPLICE S9"2 2 SECONDARY SPLICE S9'2/0 2 SECONDARY SPLICE S9'4/0 4 SECONDARY SPLICE SEVP 2 SEVERE COND. FOR POLE SETTING CREW CU Nam Quantity Description BANK10 1 SINGLE TRANS. REMOVAL, UP TO 75KVA BAYONET 1 BAYONET REMOVAL CLAMP 3 HOT-LINE CLAMP REMOVAL CUTOUT 1 FUSE CUTOUT REMOVAL DOWN3/8 1 3/8 IN. DOWNGUY REMOVAL FULLGRD 1 EQUIPMENT GROUND REMOVAL NUMBER 1 POLE TAG REMOVAL P.50/3C 1 50 FT. TYPE III CONCRETE POLE PIN 3 INSULATOR PIN REMOVAL POLECON 2 S20 REMOVAL PRIINS 4 PRIMARY INSULATOR REMOVAL RUBDOWN 16 LINE RUBBER REMOVAL, PER SECT. SMWEDGE 5 SMALL SEC.WEDGE CLAMP REMOVAL STANDOFF 3 PRI. INSULATOR STANDOFF BRACKET REMOVAL SWITCH 1 CUTOUT&ARRESTER BRKT. REMOVAL g s ■ Ott M v„ lb r 46 lk r o- I «w • s M ,rc 3�