1952 W SEVILLA BLVD RERF19-0013 ROOF PERMIT REROOF SHINGLE PERMIT PERMIT NUMBER
CITY OF ATLANTIC BEACH RERF19-0013
800 SEMINOLE ROAD ISSUED: 1/22/2019
ATLANTIC BEACH. FL 32233 EXPIRES: 7/21/2019
MUST CALL INSPECTION ' • 914 247-5814 BY 4 PM FOR NEXT DAY INSPECTION.
ALL • 'K MUST CONFORM TO THE CURRENT 6TH EDITION1 OF • ' + BUILDING
CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES .
ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY.
NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property
that may be found in the public records of this county, and there may be additional permits required from other
governmental entities such as water management districts,state agencies,or federal agencies.
JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK:
1952 W SEVILLA BLVD REROOF SHINGLE SHINGLE ROOF $15000.00
TYPE OFBUILDING USE
ZONING: :D •
• • GROUP:
169462 0435 SEVILLA GARDENS UNIT
02
COMPANY: ADDRESS: '
FORD ROOFING SYSTEMS
INC 83 Landrum Lane #104 Ponte Vedra Beach FL 32082
• ADDRESS:
TRAYNOR SEAN G 1952 SEVILLA BLVD W ATLANTIC BEACH FL 32233
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT
IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF
COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
LIST OF • .
Roll off container company must be on City approved list . Container cannot be placed on City right-of-way.
DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT
BUILDING PERMIT 4SS-0000-322-1000 0 $130.00
STATE DBPR SURCHARGE 4SS-0000-208-0700 0 $2.00
STATE DCA SURCHARGE 4SS-0000-208-0600 0 $2.00
TOTAL: $134.00
Issued Date: 1/22/2019 1 of 2
Building Permit Annlication IInc
{pta�J1(1/9/jR
_. City a#Atlantic Beach BLiil�iilg De�,artment "ALL INFORMATION
800 Seminole Road Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY
Phone: (904) 247-5826 Email: Building-Dept@coab.us IS REQUIRED.
11415
Job Address: 19.5 - 3eAl.��o� B l Vd W. A16.v'i l+ ,FL mi Number: �C—R-F 19 -- 0y t
Legal Description 45-7 09 -2.S-a9F $ay;Ela i5 rdeus CW4 d¢ Lir¢ 3 6 RE# /fo94(o�2
Valuation of Work(Replacement Cost)$/5, OUO Heated/Cooled SF Non-Heated/Cooled
• Class of Work: [--]New ❑Addition ❑Alteration ❑Repair ❑Move ❑Demo ❑Pool ❑Window/Door
• Use of existing/proposed structure(s): ❑Commercial kResidential
• If an existing structure, is a fire sprinkler system installed?: ❑Yes ❑No
• Will trees be removed in association with proposed project? ❑Yes must submit separate Tree Removal Permit ❑No
Describe in detail the type of work to be performed:
I
Florida Product Approval# io i.� /19696 for multiple products use product approval form
Property Owner Information
Name 8ee"" Zr Vtw- Address GV-16 Jd W-
city i'G State Fl- zip ,39..V 33 Phone C
E-Mail
Owner or Agent(If Agent, Power of Attorney or Agency Letter Required)
f ontractpr InfcrrnaV_n ,1
Name of Company Qc crF� S;Ur��uS `.�. Quali ging Agent Kvbf1'
Address 8S rcwc Q4- City V State —L Zip 3a06_'7_
Office Phone - .4,4.-G Job Site Contact Number (0+ 4 f
State Certification/Registration# t 3�P--7(o 199 E-Mail -rFaCd M��'�'�..Q, Q aP�•�e�; -CC>t�^
Architect Name& Phone#
Fngineer's Name& Phone tt
Workers Compensation Insurer_Aw e,-,? w Ztll fd _&.5. OR Exempt❑ Expiration Date /;;Z/__4//9
Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has
commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating
construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS,
WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS, etc. NOTICE: In addition to the requirements of this
permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and
there may be additional permits required from other governmental entities such as water management districts,state agencies, or
federal agencies.
OWNER'S AFFIDAVIT: I certifv that all the foreeoine information is accurate and that all work will be done in compliance with all
applicable laws regulating construction and zoning.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND
TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR ATTORNEY BEFORE
KF(_UKUIIV U Y - NUI ICt h L_( IV[fIVlhIV T
(Sigt re of Owner Agent) ( gnature of Contractor)
Sed and sworn to(or affirmed) befo a this da of Si gne answorn to or affirme bElforerTe this day
SIV_ 0`019 .b by
i nature of otary) (Sig a ure of Notary)
P& JACOB J.MAUST
ae ` Commission$GG ITI"3 ".°`,� JACOB J.bUUST
[ ]Personally Known OR a��a� Expires January 2,2022 P rsonally Known OR : „ Commission#GG 111991
Produced Identificatioy� FOFn nn Buopaw,ary`av� ( ]Produced Identification o�e` ExPires January 2,202�
Type of Identification: L1z1-f14elr5' CP.c,�s'C- Type of Identification: o�� UN"Pry kdg* '1 ,
EXTERIOR RESEARCH & DESIGN, LLC.
Ceriificaie of Autnorizuiion K95G3
TRINITY ERD 353 CHRISTIAN STREET,UNI?#13
OXFORD,LI 064%$
(203)262-9245
EVALUATION REPORT
GAF Evaluation Report 01506.01.08-1122
1 Campus Drive FL10124-1120
Parsippany, NJ 07054 Date of Issuance:01/03/2008
(800)766-3411 Revision 22:09/20%2017
SCUNE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: GAF Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1/R905.2.6.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation chanties. TrinitylERD requires ?, complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M. Nieminen, P.E.
„ �,,.+' �+ The facsimile seal appearing was authorized by Robert Nieminen,
„
Florida Registration No.59166, Florida DCA ANE1983 P.E.on 09/20/2017.This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity l ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
soecifically for that purpose.
TRINITY ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Asphalt Shingles
Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the
followine sections of the 6th Edition (2017) Florida Building Code and Florida Building Code. Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4/1507.1.1, Physical Properties ASTM D1970 2015
R905.2.3/R905.1.1
1507.2.5,R905.2.4 Physical Properties ASTM D3462 20i0
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016
1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011
1507.2.7.1,R90S.2.6.1 Wind Resistance TAS 107 1995
3. REFERENCES:
Entity Examination Reference Date
GAF(PDM 1915) Letter of Fquivalency Seal-A-Ridge Impact Resistant IR 01/13/2012
PRI(TST 5878) Physical Properties GAF 025-02-01 03/27;2002
PRI(TCT 5878) ASTM D3462 GAF-459-02-01 09/02/2004
PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005
PRI(TST 5878) Physical Properties GAF-324-02-01 12/01/2011
PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013
UL(TST 1740) ASTM D3462 93NK6295 11/29/1993
UL(TST 1740) ASTM D3462 99NK43835 01/12/2000
UL(TST 1740) TAS107 94NK9632 03/29/2000
UL(TST 1740) AS'IIVI D3462 0INK176632 022/022/22001
UL(TST 1740) ASTM D3161,TAS 107 01NK9226 05/21/2001
UL(TST T ij4U) AST M D3161 UINK37122 12/18/20U1
UL(TST 1740) ASTM D3462 01NK37122 12/19/2001
UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002
UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002
UL(TST 1740) ASTM D3161 03CA5367 03/11/2003
UL(TST 1740) ASTM D3462 03NK26444 10/17/2003
UL(TST 1740) ASTM D3462 04NK13850 06/07/2004
UL(TST 1740) ASTM D3161 04NK13850 06/23/2004
UL(TST 1740) ASTM D3161 04NK30546 03/10/2005
UL(TST 1740) ASTM D3462 04NK22009 05/06/2005
UL(TST 1740) ASTM D3161 04NK22009 05/09/2005
UL(TST 1740) ASTM D3462 05NK27924 02/10/2006
UL(TST 1740) ASTM D3161 05NK27924 02/11/2006
UL(TST 1740) ASTM D3161, D3462 06CA18077 06/05/2006
UL(TST 1740) ASTM D3161, D3462 06CA18074 06/16/2006
UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006
UL(TST 1740) ASTM D3462 06CA31603 12/01/2006
LII (TST 174ni ASTM n3i_6t, n3A62 nrrAA1n9S 17!77/7nnr,
UL(TST 1740) ASTM D3161 07NK05228 03/13/2007
UL(TST 1740) ASTM D3161 06CA31611 04/04/2007
UL(TST 1740) ASTM D3161 06CA61148 04/09/2007
UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007
UL(TST 1740) ASTM D3161,D71S8,D3462 08CA06100 03/13/2008
Exterior Research and Design,LLC. Evaluation Report 01506.01.0E-1122
Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVH2 EVALUATION FL10124-R20
GAF Asphalt Rnnf Shingles R. icinn 77•nQ/7n/7n17
Page 2 of 6
TRINITY ERD
Entity Examination Reference Date
UL(TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008
UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009
UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009
UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009
UL(TST 1740) ASTM D3161.D7158.D3462 09CA27281 08/27/2009
UL(TST 1740) ASTM D3161,D7158,D3462 10CA35554 03/os/1,010
III (TST 174M ACTM [)711Al,n71SR_ r_)'3dF7 1nrA136RF QC/1S/,)nln
UL(TST 1740) ASTM D3462 10CA07264 05/27/2010
UL(TST 1740) ASTM D3462 10CA11953 10/29/2010
UL(TST 1740) ASTM D3161,D7158,D3462 1ONK11951 10/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 1ONK12070 11/04/2010
UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010
UL(TST 1740) ASTM D3161,D7158,D3462 10CA53934 03/31/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/20111
U L(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03,2011
UL(TST 1740) AST MVI D3161,07i58,D3462 11CA48408 12/025/2011
UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011
UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013
UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013
UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013
UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2013
UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015
UL,LLC.(I ST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mobile,AL 10/25/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Myerstown,PA 10/20/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tuscaloosa,AL 11/11/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report, R21,Michigan Cty,IN 11/01/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report, R21,Shafter,CA 11/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Savannah,GA 11/11/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21, Minneapolis, MN 10/25/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mt.Vernon,IN 10/25/12016
111 11 r (611 IA g67S) nuality rnntrnl Incnprtinn RPnnrt R71 Raltimnra Mn 1 n17117n1 F
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tampa,FL 11/17/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Dallas,TX 11/04/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Ennis,TX 11/03/2016
UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Fontana,CA 11/01/2016
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Marquis® WeatherMax®, Royal Sovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof
shingles.
4.1.2 Camelot®, Camelots ll, Fortitude'", Glenwood'", Grand Canyon', Grand Sequoia®, Grand Sequoia® IR,
Grand Sequoia® ArmorShield'm, Monaco®, Sienna®, Timberline® American Harvest®, Timberline®
ArmorShield'"" Il, Timberline® Natural Shadow®,Timberline HD®, Timberline® Cool Series®,Timberline Ultra
HD® and Woodland® are fiberglass reinforced, laminated asphalt roof shingles.
4.1.3 Siateline" is a fiberglass reinfurced 5-tab asphalt ruuf silingie.
4.2 Hip&Ridge Shingles:
4.2.1 Seal-A-Ridge° Ridge Cap Shingles, Seal-A-Ridges IR Impact-Resistant Ridge Cap Shingles, Seal-A-Ridges
ArmorShield" Ridge Cap Shingles and Timbertex® Premium Ridge Cap Shingles are fiberglass reinforced, hip
and ridge asphalt roof shingles.
Exterior Research and Design,I.I.C. Evaluation Re_n_n_rt 01506.01.08-R22
Certificate ofAathori:ation 119503 6" EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R20
GAF Asphalt Roof Shingles Revision 22:09/20/2017
Page 3 of 6
TRINITY ERD
4.3 Accessory Starter Strips:
4.3.1 Pro-Start® Eave/Rake Starter Strip Shingles and WeatherBlocker`" Premium Eave/Rake Starter Strip Shingles
are starter strips for asphalt roof shingles.
4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS
modified bitumen starter strin nnminal 9-inch x 33 ft roll fnr lisp with asnhalt shinalps with pxnosure of 6-
inch or less.
4.3.3 StarterMatch— Starter Strip Shingles are color-coordinated starter strips for use with Grand Canyon' and
Grand Sequoia' series asphalt shingles. StarterMatchr" are installed as the second starter for Grand
Canyon®and Grand Sequoia®series installations.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Desionpr of Rprnrrl for any project on which this Evaluation Report, or previous yprsinns thereof, isA las
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
5.4 Wind Classification:
5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and
Rgf1S.7,6,1 to ASTM 113161_ Class F and/or ASTM D7158, Clacc H indicating the hincrlps are,nrrentahle fnr
use in all wind zones up to Vasd= 150 mph (V„It= 194 mph). Refer to Section 6 for installation requirements
to rneeL this wind rdting.
5.4.2 The GAF hip & ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1
and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up
to Vasd= 150 mph (Vu,,= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a
mean roof height of 60 feet or less. Calculations by a qualified design professional are required for
conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle.
S.5
r ell ._.._ J. _t_ the
__ f _.__d.ly _R._RR 1. _._l•t. _
�.� Hn Nruuul.��in u1e ruin d>jernuly�ndn have quality d55uidilCe audit In dGCOrudilCe wiiil F.A.C. rcu1C 61a20'7.
6. INSTALLATION:
6.1 Underlayment:
6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be
Locally Approved per Rule 61G20-3, per FBC 1507.2.3, 1507.2.4 or R905.2.3.
6.2 Starter Shingles or Starter Strip:
L 7 1 1..�F-.II-.a�...+ ..F Dr.. [a....a G......ID..L..[a....aer[tri,p'a h in..1.... '.A.'c.a h c r D 10 z:kcr D.......:.um, Lave/D..kC [a....a....[a..:..
—2.l a stallaaio�i o r R o->aaR a Eaves Rake caa wR >aR RN>nuR6Rca, rr eaaneR v"va.ncR r"cn ua�Rn R-arc�na nc>aaR acR >u Rr
Shingles and QuickStart Peel &Stick Starter Roll shall comply with the GAF current published instructions.
6.3 Asphalt Shingles:
6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions, using minimum four
(4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions:
Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield,
and Woodland require minimum five (5) nails per shingle.
D Clatalina rom6rac minimum civ/FI nails nor chinalo
6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6
or R905.2.5. Staples are not permitted.
6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. Contact the GAF for details.
Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-R22
Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION F1.10124-1120
GAF Asphalt Raaf Shingles Revision 22:09/20/2017
Page 4 of 6
TRINITY ERD
6.4 Hip&Ridge Shingles:
6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles, Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles and
Seal-A-Ridge ArmorShield Ridge Cap Shingles shall comply with the GAF current published instructions with
a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter
beads of Henkel"Loctite PL S30 Roof&Flashing Sealant".
11.5" Sealant
1° (292 mm) 1" Sellante
(25 mm) (25 mm) Enduit d•etancheite
• • 12"
(305 mm)
Nail
Clavo
6 5/8"-7 5/8" Clouer
(168-111
168-194 mm)
12"
(305 mm)
6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with GAF current published instructions
with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn NPI
Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant.
115, SedimNl
1" 1242 mm: 1 Setlan4
25 rm-t' crdt.rt d'etardre to
r
Val
Goocr 4,305-r mi
a
1123 rnth;
1Y
X5rnrt
6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or
R905.2.5. Staples are not permitted.
Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R22
Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R20
uAf Asphait Kooi Shingies itevision 22:uy/zu/hili
Page 5 of 6
TRINITY ERD
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 /R905.2.5.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625; (847)664-3281
END OF EVALUATION REPORT-
Exterior Research and Design,I.I.C. Evaluation Rcport 01506.01.08-1122
Certificate of Authorization#9SO3 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R20
GAF Asphalt Roof Chinolnc RP_vic_in_n 77•nQ/7n/7ni 7
Page 6 of 6