1952 W SEVILLA BLVD RERF19-0013 ROOF PERMIT REROOF SHINGLE PERMIT PERMIT NUMBER CITY OF ATLANTIC BEACH RERF19-0013 800 SEMINOLE ROAD ISSUED: 1/22/2019 ATLANTIC BEACH. FL 32233 EXPIRES: 7/21/2019 MUST CALL INSPECTION ' • 914 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL • 'K MUST CONFORM TO THE CURRENT 6TH EDITION1 OF • ' + BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. JOB ADDRESS: PERMIT TYPE: DESCRIPTION: VALUE OF WORK: 1952 W SEVILLA BLVD REROOF SHINGLE SHINGLE ROOF $15000.00 TYPE OFBUILDING USE ZONING: :D • • • GROUP: 169462 0435 SEVILLA GARDENS UNIT 02 COMPANY: ADDRESS: ' FORD ROOFING SYSTEMS INC 83 Landrum Lane #104 Ponte Vedra Beach FL 32082 • ADDRESS: TRAYNOR SEAN G 1952 SEVILLA BLVD W ATLANTIC BEACH FL 32233 WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF • . Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT BUILDING PERMIT 4SS-0000-322-1000 0 $130.00 STATE DBPR SURCHARGE 4SS-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 4SS-0000-208-0600 0 $2.00 TOTAL: $134.00 Issued Date: 1/22/2019 1 of 2 Building Permit Annlication IInc {pta�J1(1/9/jR _. City a#Atlantic Beach BLiil�iilg De�,artment "ALL INFORMATION 800 Seminole Road Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY Phone: (904) 247-5826 Email: Building-Dept@coab.us IS REQUIRED. 11415 Job Address: 19.5 - 3eAl.��o� B l Vd W. A16.v'i l+ ,FL mi Number: �C—R-F 19 -- 0y t Legal Description 45-7 09 -2.S-a9F $ay;Ela i5 rdeus CW4 d¢ Lir¢ 3 6 RE# /fo94(o�2 Valuation of Work(Replacement Cost)$/5, OUO Heated/Cooled SF Non-Heated/Cooled • Class of Work: [--]New ❑Addition ❑Alteration ❑Repair ❑Move ❑Demo ❑Pool ❑Window/Door • Use of existing/proposed structure(s): ❑Commercial kResidential • If an existing structure, is a fire sprinkler system installed?: ❑Yes ❑No • Will trees be removed in association with proposed project? ❑Yes must submit separate Tree Removal Permit ❑No Describe in detail the type of work to be performed: I Florida Product Approval# io i.� /19696 for multiple products use product approval form Property Owner Information Name 8ee"" Zr Vtw- Address GV-16 Jd W- city i'G State Fl- zip ,39..V 33 Phone C E-Mail Owner or Agent(If Agent, Power of Attorney or Agency Letter Required) f ontractpr InfcrrnaV_n ,1 Name of Company Qc crF� S;Ur��uS `.�. Quali ging Agent Kvbf1' Address 8S rcwc Q4- City V State —L Zip 3a06_'7_ Office Phone - .4,4.-G Job Site Contact Number (0+ 4 f State Certification/Registration# t 3�P--7(o 199 E-Mail -rFaCd M��'�'�..Q, Q aP�•�e�; -CC>t�^ Architect Name& Phone# Fngineer's Name& Phone tt Workers Compensation Insurer_Aw e,-,? w Ztll fd _&.5. OR Exempt❑ Expiration Date /;;Z/__4//9 Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS,TANKS,and AIR CONDITIONERS, etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts,state agencies, or federal agencies. OWNER'S AFFIDAVIT: I certifv that all the foreeoine information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR ATTORNEY BEFORE KF(_UKUIIV U Y - NUI ICt h L_( IV[fIVlhIV T (Sigt re of Owner Agent) ( gnature of Contractor) Sed and sworn to(or affirmed) befo a this da of Si gne answorn to or affirme bElforerTe this day SIV_ 0`019 .b by i nature of otary) (Sig a ure of Notary) P& JACOB J.MAUST ae ` Commission$GG ITI"3 ".°`,� JACOB J.bUUST [ ]Personally Known OR a��a� Expires January 2,2022 P rsonally Known OR : „ Commission#GG 111991 Produced Identificatioy� FOFn nn Buopaw,ary`av� ( ]Produced Identification o�e` ExPires January 2,202� Type of Identification: L1z1-f14elr5' CP.c,�s'C- Type of Identification: o�� UN"Pry kdg* '1 , EXTERIOR RESEARCH & DESIGN, LLC. Ceriificaie of Autnorizuiion K95G3 TRINITY ERD 353 CHRISTIAN STREET,UNI?#13 OXFORD,LI 064%$ (203)262-9245 EVALUATION REPORT GAF Evaluation Report 01506.01.08-1122 1 Campus Drive FL10124-1120 Parsippany, NJ 07054 Date of Issuance:01/03/2008 (800)766-3411 Revision 22:09/20%2017 SCUNE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation chanties. TrinitylERD requires ?, complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. „ �,,.+' �+ The facsimile seal appearing was authorized by Robert Nieminen, „ Florida Registration No.59166, Florida DCA ANE1983 P.E.on 09/20/2017.This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity l ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained soecifically for that purpose. TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the followine sections of the 6th Edition (2017) Florida Building Code and Florida Building Code. Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4/1507.1.1, Physical Properties ASTM D1970 2015 R905.2.3/R905.1.1 1507.2.5,R905.2.4 Physical Properties ASTM D3462 20i0 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1,R905.2.6.1 Wind Resistance ASTM D7158 2011 1507.2.7.1,R90S.2.6.1 Wind Resistance TAS 107 1995 3. REFERENCES: Entity Examination Reference Date GAF(PDM 1915) Letter of Fquivalency Seal-A-Ridge Impact Resistant IR 01/13/2012 PRI(TST 5878) Physical Properties GAF 025-02-01 03/27;2002 PRI(TCT 5878) ASTM D3462 GAF-459-02-01 09/02/2004 PRI(TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI(TST 5878) Physical Properties GAF-324-02-01 12/01/2011 PRI(TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 UL(TST 1740) ASTM D3462 93NK6295 11/29/1993 UL(TST 1740) ASTM D3462 99NK43835 01/12/2000 UL(TST 1740) TAS107 94NK9632 03/29/2000 UL(TST 1740) AS'IIVI D3462 0INK176632 022/022/22001 UL(TST 1740) ASTM D3161,TAS 107 01NK9226 05/21/2001 UL(TST T ij4U) AST M D3161 UINK37122 12/18/20U1 UL(TST 1740) ASTM D3462 01NK37122 12/19/2001 UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002 UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002 UL(TST 1740) ASTM D3161 03CA5367 03/11/2003 UL(TST 1740) ASTM D3462 03NK26444 10/17/2003 UL(TST 1740) ASTM D3462 04NK13850 06/07/2004 UL(TST 1740) ASTM D3161 04NK13850 06/23/2004 UL(TST 1740) ASTM D3161 04NK30546 03/10/2005 UL(TST 1740) ASTM D3462 04NK22009 05/06/2005 UL(TST 1740) ASTM D3161 04NK22009 05/09/2005 UL(TST 1740) ASTM D3462 05NK27924 02/10/2006 UL(TST 1740) ASTM D3161 05NK27924 02/11/2006 UL(TST 1740) ASTM D3161, D3462 06CA18077 06/05/2006 UL(TST 1740) ASTM D3161, D3462 06CA18074 06/16/2006 UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006 UL(TST 1740) ASTM D3462 06CA31603 12/01/2006 LII (TST 174ni ASTM n3i_6t, n3A62 nrrAA1n9S 17!77/7nnr, UL(TST 1740) ASTM D3161 07NK05228 03/13/2007 UL(TST 1740) ASTM D3161 06CA31611 04/04/2007 UL(TST 1740) ASTM D3161 06CA61148 04/09/2007 UL(TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007 UL(TST 1740) ASTM D3161,D71S8,D3462 08CA06100 03/13/2008 Exterior Research and Design,LLC. Evaluation Report 01506.01.0E-1122 Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVH2 EVALUATION FL10124-R20 GAF Asphalt Rnnf Shingles R. icinn 77•nQ/7n/7n17 Page 2 of 6 TRINITY ERD Entity Examination Reference Date UL(TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008 UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009 UL(TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009 UL(TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009 UL(TST 1740) ASTM D3161.D7158.D3462 09CA27281 08/27/2009 UL(TST 1740) ASTM D3161,D7158,D3462 10CA35554 03/os/1,010 III (TST 174M ACTM [)711Al,n71SR_ r_)'3dF7 1nrA136RF QC/1S/,)nln UL(TST 1740) ASTM D3462 10CA07264 05/27/2010 UL(TST 1740) ASTM D3462 10CA11953 10/29/2010 UL(TST 1740) ASTM D3161,D7158,D3462 1ONK11951 10/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 1ONK12070 11/04/2010 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010 UL(TST 1740) ASTM D3161,D7158,D3462 10CA53934 03/31/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/20111 U L(TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03,2011 UL(TST 1740) AST MVI D3161,07i58,D3462 11CA48408 12/025/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011 UL,LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013 UL,LLC.(TST 9628) ASTM D3161 12CA38083 02/26/2013 UL,LLC.(TST 9628) ASTM D3161 13CA32332 06/18/2013 UL,LLC.(TST 9628) ASTM D3161 13CA37934 08/02/2013 UL,LLC.(TST 9628) ASTM D3161,D7158,D3462 4786875675 07/17/2015 UL,LLC.(I ST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mobile,AL 10/25/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Myerstown,PA 10/20/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tuscaloosa,AL 11/11/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report, R21,Michigan Cty,IN 11/01/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report, R21,Shafter,CA 11/17/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Savannah,GA 11/11/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21, Minneapolis, MN 10/25/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Mt.Vernon,IN 10/25/12016 111 11 r (611 IA g67S) nuality rnntrnl Incnprtinn RPnnrt R71 Raltimnra Mn 1 n17117n1 F UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Tampa,FL 11/17/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Dallas,TX 11/04/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Ennis,TX 11/03/2016 UL,LLC.(QUA 9625) Quality Control Inspection Report,R21,Fontana,CA 11/01/2016 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Marquis® WeatherMax®, Royal Sovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof shingles. 4.1.2 Camelot®, Camelots ll, Fortitude'", Glenwood'", Grand Canyon', Grand Sequoia®, Grand Sequoia® IR, Grand Sequoia® ArmorShield'm, Monaco®, Sienna®, Timberline® American Harvest®, Timberline® ArmorShield'"" Il, Timberline® Natural Shadow®,Timberline HD®, Timberline® Cool Series®,Timberline Ultra HD® and Woodland® are fiberglass reinforced, laminated asphalt roof shingles. 4.1.3 Siateline" is a fiberglass reinfurced 5-tab asphalt ruuf silingie. 4.2 Hip&Ridge Shingles: 4.2.1 Seal-A-Ridge° Ridge Cap Shingles, Seal-A-Ridges IR Impact-Resistant Ridge Cap Shingles, Seal-A-Ridges ArmorShield" Ridge Cap Shingles and Timbertex® Premium Ridge Cap Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. Exterior Research and Design,I.I.C. Evaluation Re_n_n_rt 01506.01.08-R22 Certificate ofAathori:ation 119503 6" EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R20 GAF Asphalt Roof Shingles Revision 22:09/20/2017 Page 3 of 6 TRINITY ERD 4.3 Accessory Starter Strips: 4.3.1 Pro-Start® Eave/Rake Starter Strip Shingles and WeatherBlocker`" Premium Eave/Rake Starter Strip Shingles are starter strips for asphalt roof shingles. 4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral-surfaced, fiberglass-reinforced, self-adhering SBS modified bitumen starter strin nnminal 9-inch x 33 ft roll fnr lisp with asnhalt shinalps with pxnosure of 6- inch or less. 4.3.3 StarterMatch— Starter Strip Shingles are color-coordinated starter strips for use with Grand Canyon' and Grand Sequoia' series asphalt shingles. StarterMatchr" are installed as the second starter for Grand Canyon®and Grand Sequoia®series installations. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Desionpr of Rprnrrl for any project on which this Evaluation Report, or previous yprsinns thereof, isA las used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and Rgf1S.7,6,1 to ASTM 113161_ Class F and/or ASTM D7158, Clacc H indicating the hincrlps are,nrrentahle fnr use in all wind zones up to Vasd= 150 mph (V„It= 194 mph). Refer to Section 6 for installation requirements to rneeL this wind rdting. 5.4.2 The GAF hip & ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd= 150 mph (Vu,,= 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. S.5 r ell ._.._ J. _t_ the __ f _.__d.ly _R._RR 1. _._l•t. _ �.� Hn Nruuul.��in u1e ruin d>jernuly�ndn have quality d55uidilCe audit In dGCOrudilCe wiiil F.A.C. rcu1C 61a20'7. 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Starter Shingles or Starter Strip: L 7 1 1..�F-.II-.a�...+ ..F Dr.. [a....a G......ID..L..[a....aer[tri,p'a h in..1.... '.A.'c.a h c r D 10 z:kcr D.......:.um, Lave/D..kC [a....a....[a..:.. —2.l a stallaaio�i o r R o->aaR a Eaves Rake caa wR >aR RN>nuR6Rca, rr eaaneR v"va.ncR r"cn ua�Rn R-arc�na nc>aaR acR >u Rr Shingles and QuickStart Peel &Stick Starter Roll shall comply with the GAF current published instructions. 6.3 Asphalt Shingles: 6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6,with the following exceptions: Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield, and Woodland require minimum five (5) nails per shingle. D Clatalina rom6rac minimum civ/FI nails nor chinalo 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the GAF for details. Exterior Research and Design,I.I.C. Evaluation Report 01506.01.08-R22 Certificate of Authorization#9503 6'EDITION(2017)FBC NON-HVHZ EVALUATION F1.10124-1120 GAF Asphalt Raaf Shingles Revision 22:09/20/2017 Page 4 of 6 TRINITY ERD 6.4 Hip&Ridge Shingles: 6.4.1 Installation of Seal-A-Ridge Ridge Cap Shingles, Seal-A-Ridge IR Impact-Resistant Ridge Cap Shingles and Seal-A-Ridge ArmorShield Ridge Cap Shingles shall comply with the GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter beads of Henkel"Loctite PL S30 Roof&Flashing Sealant". 11.5" Sealant 1° (292 mm) 1" Sellante (25 mm) (25 mm) Enduit d•etancheite • • 12" (305 mm) Nail Clavo 6 5/8"-7 5/8" Clouer (168-111 168-194 mm) 12" (305 mm) 6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn NPI Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant. 115, SedimNl 1" 1242 mm: 1 Setlan4 25 rm-t' crdt.rt d'etardre to r Val Goocr 4,305-r mi a 1123 rnth; 1Y X5rnrt 6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. Exterior Research and Design,LLC. Evaluation Report 01506.01.08-R22 Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R20 uAf Asphait Kooi Shingies itevision 22:uy/zu/hili Page 5 of 6 TRINITY ERD 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 /R905.2.5.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625; (847)664-3281 END OF EVALUATION REPORT- Exterior Research and Design,I.I.C. Evaluation Rcport 01506.01.08-1122 Certificate of Authorization#9SO3 6'EDITION(2017)FBC NON-HVHZ EVALUATION FL10124-R20 GAF Asphalt Roof Chinolnc RP_vic_in_n 77•nQ/7n/7ni 7 Page 6 of 6