556 TIMBER BRIDGE LN - BLOWER TEST FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
" Envelope Leakage Test Report
Project Name: Atlantic Beach Country Club Lot 177 Builder Name: Toll Brothers
Street: 556 Timber Bridge Permit Office:
City,State,Zip: Atlantic Beach. Fl. 32233 Permit Number:
Owner: Jurisdiction:
Design Location: V n 1 : 3 ,7g
Envelope Leakage Test Results Leakage Characteristics
Regression Data:
C: n: R: CFM(50): 3140
Multi Point Test Data:
ELA:
HOUSE PRESSURE FLOW:
1 50 Pa 3140 cfm EqLA:
2 Pa cfm ACH:
3 Pa cfm ACH(50): 5.0
4 Pa cfm SLA:
5 Pa cfm
6 Pa cfm
IL, 402.4.2.1 Testing option. Building envelope tightness and insulation installation shall be considered acceptable when tested air leakage is less
than seven air changes per hour(ACH)when tested with a blower door at a pressure of 33.5 psf(50 Pa).Testing shall occur after rough in and after
installation of penetrations of the building envelope,including penetrations for utilities.plumbing,electrical.ventilation and combustion appliances.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed;
2.Dampers shall be closed,but not sealed,including exhaust,intake,makeup air,backdraft and flue dampers;
3.Interior doors shall be open;
4.Exterior openings for continuous ventilation systems and heat recovery ventilators shall be closed and sealed:
5.Heating and cooling system(s)shall be turned off;
6.HVAC ducts shall not be sealed;and
7.Supply and return registers shall not be sealed.
Florida Building Code requires NE T
I hereby certify that the above envelope testing to confirm envelope leakage SOF 9TF0
leakage performance results demonstrate be performed by a Class 1 � ._
compliance with Florida Energy Code _ e
re uirements in accordance with Florida Energy Gauge Certified ••
, p
q Energy Rater. Certified Florida t
Section Table B-1.1.2. v
Class 1 raters can be found at: E.
"`fff///j http://energygauge.com/search.htm ,aloft", 6 :
:
Signature , ,
4s,
Printed Name: Daniel Brohl
Florida Rater Certification#: 0996173 BUILDING OFFICIAL:
DATE: 1/25/2019 DATE:
11111.- EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software