Loading...
265 PINE ST ROOF NON SHING PERM I)IJ N. I ROOF NON SHINGLE PERMIT PERMIT NUMBER ROOF19-0013 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ISSUED: 1/31/2019 1 19 EXPIRES: 7/30/2019 ATLANTIC BEACH. FIL 32233 MUST CALL INSPECTION PHONE LINE (904) 247-5814 BY 4 PM FOR NEXT DAY INSPECTION. ALL WORK MUST CONFORM TO THE CURRENT 6TH EDITION (2017) OF THE FLORIDA BUILDING CODE, NEC, IPMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. JOB ADDRESS: PERMIT TYPE: DIESCRIPTION: VALUE OF WORK: 265 PINE ST ROOF NON SHINGLE metal re-roof $14000.00 TYPE OF REALESTATE ZONING: BUILDING USE SUBDIVISION: CONSTRUCTION: NUMBER: GROUP: 1705610100 SALTAIR SEC 03 COMPANY: ADDRESS: CITY: STATE: ZIP: FORD ROOFING SYSTEMS 83 Landrum Lane #104 Ponte Vedra Beach FL 32082 INC ADDRESS: CITY: STATE: ZIP: MAIRE ANITA PHYLLIS 265 PINE ST ATLANTIC BEACH FL 32233-4013 GELLER WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. LIST OF CONDITIONS �Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. DESCRIPTION ACCOUNT QUANTITY PAID f BUILDING PERMIT 455-0000-322-1000 0 BUILDING PLAN CHECK 45S-0000-322-1001 0 STATE DBPR SURCHARGE 4SS-0000-208-0700 0 STATE DCA SURCHARGE 4S5-0000-208-0 0 Issued Date: 1/31/2019 1 of 2 -51 . T City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road -5445 P-oo Ft q -co flantic Beach, Florida 32233 Phone(904)247-5826 - Fax(904)247-5845 E-mail- building-dept@coab.us Date routed: City web-site: hftp://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: �, �ent review required Yes "'No Building' :�) 7 Applicant: Cc)J ko P-1 a—n—ni n-g—&-fo n i n g Tree Administrator Project: fooF Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [PA/pproved. ElDenied. E]Not applicable (Circle one.) Comments: PLANNING &ZONING Reviewed by: Date: /- 576 TREE ADMIN. Second Review: ElApproved as revised. ElDenied. E]Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: DApproved as revised. FIDenied. F]Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 BuildinLy Permit Annfication L�n dated 1019118 OFFICE COPY �i City of/Atlantic Beach B u Hiding Department "ALL INFORMATION 800 Seminole Road, Atlantic Beach, FL 32233 HIGHLIGHTED IN GRAY Phone: (904) 247-5826 Email: Building-Dept@coab.us IS REQUIRED. Job Address:,7(o6 W,, e4v^1 F rt- 32.2-3'3 Permit Number: "Fiq -C)Q� Legal Description 06 -a6 9,197 5,J�eir 50,3 Lots 536 0/ft 5;0O1--2G61 RE# .5 4P V-7 -7 31t Valuation of Work(Replacement Cost)$ 14- 1000 Heated/Cooled SF Non-Heated Cooled • ClassofWork: E]New []Addition DAIteration []Repair EIMove []Demo []Pool E]Window/Door W • Use of existing/proposed structure(s): OCommercial OResidential JAN 2 3 201V cn If an existing structure, is a fire sprinkler system installed?: E]Yes E]No _J Will tree(s) be removed in association with proposed pro'ect? E]Yes(must submit separaieTree- Removal Perm-9-(AM FDescribe in detail the type of work to be performed: A> 0 mu 6 U C.) 0 0 < , U IQ 6 Florida Product Approval# for multiple products use product a rJ I&F4 81 ILL PropertV Owner Information 0 Name A*-4A.T,, LE Cn RAVII;.5 dei�er M r6 Add ress;26,5 e.;'&4,d < L- z City LL -WWA-J_je� Bee-tk State FL zip 3p.�L3*3 Phone -33*: $+95 LL E-Mail U M Owner or Agent(If Agent,Power of Attorney or Agency Letter Required) LLJ Contractor!nf-_rrn_ati-_n W 0 W L.0 U) W 3: Name of Company rcj 1Z QualiVin&Agent R.Wj4- 4"-A-54-5; __Ba� State zip LLI Address 1,91 4- Jv� 16 4- City YVV%P-V1J.(A I. Office Phone Job Site Contact Number :3 14 &-7 1 State Certification/Registration# CeZ, r3a _7& -9 8 E-Mail:f. - 6-3 aewr4;1. e_o#-f_ CoL rctjijl��J� Architect Name& Phone# Engineer's Name&Phone# Workers Compensation Insurer. �otvie,&At Zt./)*61- 17A5. OR Exempt Ei Expiration Date Application is hereby made to obtain a permit to clo the worK and installations as indicated. I certify that no work o�insta'I lation 'has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all the laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING,SIGNS, WELLS,POOLS, FURNACES, BOILERS,HEATERS,TANKS,and AIR CONDITIONERS,etc. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county,and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. OWNER'S AFFIDAVIT: I certify that all the fore2oine information is accurate and that all work will be done in comoliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER ORAN ATTORNEY FORE RECID�_4DINU_ YOU- - 0 TICE OF COMf%EN LIVILN I L:�� 9eJ1&X-- - (Signature of Owner or Agent) (.fig nKe of Contractor) �S�Inecl and sworn to (or affirmed) bef me this day of S ne an sworn to(or affirmekti—ef-os7methis*-121day of e-AM b JACOGJARANIST n re of Notary) Signature o"otary) JACOB I M"T EWw bm"Z 2022 8WA6d7hNk1d9dNWA&"y C4mw"w#GG 171993 MMsonally Known OR /Wer'sonally Know OR ddlr�educecl identification I Produced Identification _Ilvewry 8MX%d1N&JCWW0WySCreW. Type of Identification: r—L Jwk-1/3-15 Lieew Type of Identification: A00" lnwu\ o. FLORIDA PRODUCT APPROVAL Gulkoa�t CTURING TM YL LOK Fqj1' P-1- _�Git 0K_1*�_AAffl1E_RQ0"AN1EL0Vf_R_1 ai� -if.,I W A RIM, In�ka4m 11 L-144L 14;XT Product Evaluation Report. OFFICE COPY GULF COAST SUPPLY & MANUFACTURING, LLC. 26 Ga. GulfLokTM 16" Wide Roof Panel over 1SI32" Plywood Florida Product Approval #11651.16 R3 Florida Building Code 2017 Per Rule 61 G20-3 Method: 1 -D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61 G20-3.005(l)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. %%01111111", 14429 SW 2nd Place, Suite G30 10 \EL S Newberry, FL 32669 C E IV 0 19 Z*: No. 75519 Engineer Evaluator: Dan Kuhn, RE. #75519 :P.. E 0 - STAT OF Florida Evaluation ANE ID- 10743 0 R 10 /0 03 Valiclator: /,,IVA L Locke Bowden, RE. #49704 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1 — 5 FL#11651.16 R3 OCTOBER 5,2017 PRODUCT EVALUATION REPORT INKUHN ENGINEERING, LLC 1200 CLINT MOORE RD. SUITE 9, BOCA RATON, FL 33487 - FL COA #30464 GulkoaA FLORIDA PRODUCT APPROVAL 14 CTURING LOK TM Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Product Description: GulfLokTM' 7/8" Nailstrip Roof Panel, Minimum 26 Ga. Steel, Maximum 16" Coverage, Roof panel rpstrained with fasteners into minimum 15A.2" plywood decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2017 Section 1507.4.3. Paint Finish Optional Yield Strength: 50.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 16" Coverage Maximum Female Rib: 7/8" Ta I I Male Rib: 3/4" Tall Rib with Slotted Strip Panel Seam: Snap Lock Panel Clip: 24 Ga. 7inc Altimimirn Cnatpd �tppl, 24" 1 ong Used at CornerZone5 only, where required design pressures exceed-121.75 psf. Panel Fastener: Through Panel Slot: (1)#10-1 2xl" Pancake Type A 1/4" Minimum Penetration through Plywood. Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 Substrate Description: Minimum '5/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/Florida Building Code 2017. Design Uplift Pressures: Table "A" Maximum Design Pressures Roof Areas Assembly A Assembly B Assembly C Maximum Design Pressures -63.5 psf -12 1.7 5 psf -161 psf Fastener Spacing 5%'O.0 51/a"O.0 5%"0.C Sealant No Yes No Panel Clip No No Yes *Design Pressure includes a Safety Factor=2.0. FL#11651.16 R3 e OCTOBER 5,20117 PRODUCT EVALUATION REPORT ----------- -------------- KUHN ENGINEERING, LLC 1200 CLINT MOORE RD. SUITE 9, BOCA RATON, FL 33487 - FL COA #30464 St FLORIDA PRODUCT APPROVAL Gulkod 14 SUPF_'� � MANUFACTURING TM LOK (MR 1 St3l-PUMOOD: Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2017, sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load rpqtjirpmpnts of thp Florida Building Code 2017, as rplates to Rtilp 61620-3, Performance Standards: The product described herein has demonstrated compliance with: UL 580-06 -Test for Uplift Resistance of Roof Assemblies UL 1897-12 - Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94/ 1897-98 Uplift Test Force Engineering &Testing, Inc. (FBC Organization #TST-5328) Report No. 117-0301 T-1 OA-C, Dated 07/26/2013 2. TAS 125 Architectural Testing, Inc. (FBC Organization #TST-1 527) Report No. B9000.01-450-18, Dated 12/122012 3. Certificate of Independence By Dan Kuhn, RE. (FL# 75519) @ Kuhn Engineering, LLC (FBC Organization #ANE ID: 10743) Test Standard Equivalence: 1 The UL 580-94 test standard is equivalent to the Ul 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 6 1 G20-3.005(3)for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2017 section 1507.1.1. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. FL# 11651.16 R3 e OCTOBER 5,2017 PRODUCT EVALUATION REPORT KUHN ENGINEERING, LLC 1200 CLINT MOORE RD. SUITE 9. BOCA RATON. F1_ 33487 - FL COA #30464 UlWut UUFY zN! FLORIDA PRODUCT APPROVAL 1q, GuIfCoa�t 14 SUPPLY & MANUFACTURING TM LOK -PL 6-GA�-WLFiC)�,YAB�'VMERGOF-PANELjOVIER 15/32"� YWOOD !Ala Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL#11651.16 R3 e OCTOBER 5,2017 PRODUCT EVALUATION REPORT KUHN ENGINEERING, LLC 1200 CLINT MOORE RD SUITE 9, BOCA RATON, FL 33487 FL COA#30464 UWU WHY WW Gulkoa�t SUPPLY & MANUFACTURING 010 1P !Vm 0 4 -=-ATRUT)U-177-I T ENGINEER LOAD TABLE: 26 Ga. GulfLokTM 16" Wide Roof Panel over 15/32" Plywood Buildings having a Roof Mean Height !s� 20'-0"; Roof Slope: 2"/12" - 12"112" Gable or Hip Roof; Wind Speeds 120- 180mph, Exposure C, Risk Category 11, Enclosed Building, based on Florida Building Code 2017. 120 130 140 150 160 170 180 WHND FASTENER SUBSTRATE (MIN 1/4" (MIN.15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER SPEED Penetr"ation) SPACING SPACING SPACING SPACING SPACING SPACING SPACING ZONEI (1)#10-120" CDX ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A PLYWOOD ZONE2 (1)#10-12xl" CDX ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY A ASSEMBLY B ASSEMBLY B I PLYWOOD ZONE 3 (1)#10-12xl" CDX ASSEMBLY A ASSEMBLY A ASSEMBLY 8 ASSEMBLY B ASSEMBLY B ASSEMBLY B ASSEMBLY B PLYWOOD I I I I I I 1.) PANEL DESCRIPTION: GULFLOKTM, MIN. 26 GA, 7/8" RIB, 16" MAXIMUM COVERAGE, SNAP SEAM. 2.) PANEL FASTENER:THROUGH PANEL SLOT (1)#10-1 2X1" PANCAKE TYPE A, 1/4" MIN. PENETRATION THROUGH PLYWOOD. 3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: -63.S PSF AT S1/8"O.C.ASSEMBLY A, -1 21.7S PSF AT S1/8"O.C. WITH SEALANT ASSEMBLY B, -161 PSF AT 51/8"O.C. WITH CLIP ASSEMBLY C. PRESSURE BASED ON UL 580/UL 1897 TESTING BY FORCE ENGINEERING & TESTING. 4.)PLYWOOD DECKING: MIN.15/32" THICK, APA RATED PLYWOOD, GRADE C-D. MUST BE DESIGNED IN ACCORDANCE WITH FBC 2017 5.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.8S)MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2017. ZONE 2 HIP ROOF a Note:Dimension(a)is defined as 10% of the minimum width of the building or ZONE 3 40% of the mean height of the roof,whichever is smaller,however, (a)cannot be a less than either 4%of the minimum width of the building or 3 feet. ASSEMBLYA RIDGE --16"COVERAGE Z ZONE 1 ONE 1 01(M2 X V TYPE A PANCAKE SPACING:SEE UPLIFT TABLE EAVE ASSEMBLY B ZONE 2 GABLE ROOF 114"-5/16'DIAMETER BEAD OF TITEBOND SEALANT I I I _'a -RIDGE SPACING:SEE UPLIFT TABLE ASSEMBLY C W/CLIP —a ZONE I Gullok"CLIP 24 GA. (1)#10-12 X V TYPE A PANCAKE SPACING:SEE UPLIFT TABLE -ZONE 3 EAVE FL#11651.16 R3 OCTOBER S,2017 L PRODUCT EVALUATION REPORT INKUHN ENGINEERING, LLC 1200 CLINT MOORE RD. SUITE 9,BOCA RATON,FL 33487 -FL COA#313464 urrlu= uur 11 lazaLw Gulkoast ��UPPLY 6 MANUFACTURING Fir- A I& K TIVI FLORIDA PRODUCT APPROVAL NO. 11651.16 R3 ASSEMBLY A - 'VER - GE ItY Uuvr- /Au (1) #10-12 X 1"TYPE A PANCAKE c' ,5PAUNG- UPLIF4 I ABLE ASSEMBLY13 1/4"-5/16" DIAMETER BEAD OF TITEBOND SEALANT (1) #10-12 X 1"TYPE A PANCAKE SPACiNG: SEE UPUFT TABLE ASSEMBLY C W/CLIP Gulfl-ok— CLIP 24 GA. -4110-12 X 1"TYPE A PANCAKE .,PAr.INr,- ,q;=;= I IPI jr-7 TARI F: �EL S \,\CEtV STATE op 'k, 0 FL#11651.16R3*OCTOBER5,2017 METAL ROOF PANEL DETAIL KUHN ENGINEERING, LLC 1200 CLINT MOORI- RD. SUITE (), BOCA RATON, FL 33487 - Ft. COA �30464