1596 Maritime Oak Dr RES18-0358 dwgs 9DREAM FINDERS HOMES
ZALUPSKI RESIDENCE
ATLANTIC BEACH COUNTRY CLUB, LOT 136
ATLANTIC BEACH, FLORIDA
DEN IfL,---D
ARCHITECTURAL SYMBOLS LEGEND
DRAWING INDEX
ARCHITECTURAL ABBREVIATIONS LEGEND
BUILDING CODE SUMMARY
SECTION & DETAIL MARKERS:
SECTION NO.
41_4X _ _ X
A000- A000
.SHEET NO.
BUILDING SECTION
SECTION NO.
_ — _ _ X
A000
SHEET NO.
DETAILIWALL SECTION
SECTION No.
x
A000
��.•� SHEETNO.FXD
SYMBOLS:
00
OA
ilw_-3
DOOR NUMBER MARK
WINDOW MARK
VERTICAL ELEVATION MARK
NORTH ARROW
ARCHITECTURAL STRUCTURAL
ABV
AC
AFF
AHU
BLK
CABS
CLG
CHR
COFF
COL
COND
CRN
CVAC
DBL
DIAG
DR
DRY
DW
FB
FUR
FP
FXT
GLS
HB
KS
LAV
LT
MRBL
MC
MIR
MTL
OH
OPNG
OPT
R & S
REF
SD
SDLTS
ABOVE
AIR CONDITIONER
ABOVE FINISHED FLOOR
AIR HANDLER UNIT
BLOCK
CABINETS
CEILING
CHAIR RAIL
COFFERED
COLUMN
CONDENSER
CROWN MOULDING
CENTRAL VACUUM SYSTEM
DOUBLE
DIAGONAL
DOOR
DRYER
DISHWASHER
FLOOR NE (MAT. CHANGE)
FLOOR
FIREPLACE
FIXED
FIXTURE
GLASS
HOSE BIB
KNEE SPACE
LAVATORY
LAUNDRY TUB
MARBLE
MEDICINE CABINET
MIRROR
METAL
OVERHEAD
OPENING
OPTIONAL
CLOTHES ROD and SHELF
REFRIGERATOR
SOAP DISH
SIDE LIGHTS
SGD
SH (2)
SHWR
TB
TPH
T&S
TEMP
TR
VOL
WC
WD
WH
WNCT
WS
WASH
SLIDING GLASS DOOR
SHELVES (QUANITY)
SHOWER
TOWEL BAR
TOILET PAPER HOLDER
TUB and SHOWER
TEMPERED
TRANSOM
VOLUME
WATER CLOSET
WOOD
WATER HEATER
WAINSCOT
WATER SOFTENER
WASHER
CODE ENFORCEMENT JURISDICTION: DUVAL COUNTY
ZONING CODE: THE PROPOSED STRUCTURE COMPLIES WITH THE REQUIREMENTS OF
CHAPTER 656, ZONING CODE FOR RESIDENTIAL DISTRICTS, INCL MAX BLDG
HGT OF 35'
A000 COVER, ARCH SYMBOLS & SHT INDEX
A100FOUNDATION PLAN
A110 1st LEVEL FLOOR PLAN
ZONING CLASSIFICATION: N/A
WIND ZONE: WA
A120 2nd LEVEL FLOOR PLAN
FL BUILDING CODE -RESIDENTIAL: 2017
FL BUILDING CODE -PLUMBING: 2017
FL BUILDING CODE - MECHANICAL: 2017
FL BUILDING CODE -FUEL GAS: 2017
NATIONAL ELECTRIC CODE: 2014
FL FIRE PREVENTION CODE: 2017
A160 ROOF PLAN
A200 BUILDING ELEVATIONS -FRONT/RIGHT
A201 BUILDING ELEVATIONS - REAR/LEFT
OCCUPANCY CLASSIFICATION: RESIDENTIAL
CONSTRUCTION TYPE: VB
A400 WALL SECTIONS
SPRINKLED: NO
FIRE DISTRICT: NO
A401 WALL SECTIONS
DESIGN CRITERIA:
APPROX HEIGHT AFG: 33'-2 9/16" MEAN ROOF HEIGHT AFF: 29'-1 3/4"
A500 TYPICAL DETAILS
BUILDING AREA:
1st FLOOR: 1969
2nd FLOOR: 1679
A501 TYPICAL DETAILS
OCCUPANTLOAD N/A MIN EXITS: NIA MAX DIST: N/A
OCCUPANT LOAD: N/A MINEXITS:N/A MAXDIST:N/A
TOTAL LIVING: 3648
COVERED PORCH: 367
ENTRY: 111
GARAGE: 570
2nd LEVEL COVERED
PORCH: 84
OCCUPANT LOAD: WA MIN EXITS: N/A MAX DIST: N/A
LOTAREA:
GROSSAREf� PUD COMPLIANT
ELECTRICAL
MECHANICAL
BUILDING VOLUME:
1st FLOOR: 20,280
2nd FLOOR: 15,651
E100 1st LEVEL ELECTRICAL PLAN
TOTAL NON -LIVING: 1132
TOTAL UNDER ROOF: 4780
E101 2nd LEVEL ELECTRICAL PLAN
TOTAL LIVING: 35,931
CONSTRUCTION
NOTES:
N/A
PLUMBING
Q
0
w
ti
X
z
O
0
w
F—
tds z
true design studios
LL
4745 SUTTON PARK CT., SUITE 402
JACKSONVILLE, FLORIDA 32224 w
P 904.821.5200 F 904.992.8700
WWW.TRUEDESIGNSTUDIOS.NET -�
U
07
0
w
F—
z
w
w
p
LL
- O
0-
c:)
LO
U)
w
J
Q
U
U)
O
z
Q
f
360 Corporate Way Cn U)
Orange Park, FL 32073 z
www.dreamfindershomes.com
Q
ry
0
w
w
w
r
F—
w
.� J
2 U
U)UO
z = 0
w z
Doo O
J w � o
Q ry
N
ATLANTIC BEACH
COUNTRY CLUB O
LOT 136 p
O
DUVAL COUNTY/FL p
O
PROJECT NO: O
2018.003342 z
DATE:
04-25-18 Q
DRAWN: JAC U
CHKD: DWR
REVISIONS:
F-
07-05-18 JAC
z
07-25-18 KLH 0
08-23-18 KLH U
10-19-18 DWR
0
0
D
AOOO07
F—
O
z
�W
w00
1-' O
��U
awe
c,6 I.-
w Z 0
00
L
ARCH ITECTURAL FOUNDATION PLAN
SCALE: %4" = l'-0"
z
O
tds w
z
Cif
true design studios 0-
4745 SUTTON PARK CT., SUITE 402
JACKSONVILLE, FLORIDA 32224 W
P 904.821.5200 F 904.992.8700
WWW.TRUEDESIGNSTUDIOS.NET
U)
w
Q
rzLow nn
V
U)
W
or
LL
Z -1c
O
Ln
U)
w
U
a U
Z_
Q
360 Corporate Way
Orange Park, FL 32073 z_
www.dreamfindershomes.com ?�
Q
OC
W
U)
W
2
I—
W
W U
U)� o F-
F-
n z= 0
w z
0 p O
J W � o
N
ATLANTIC BEACH
COUNTRY CLUB O
LOT 136 O
O
DUVAL COUNTY/FL p
O
O
PROJECT NO: Q
2018.003342 z
DATE: 04-25-18 0
DRAWN: JAC i—
CHKD: DWR U
REVISIONS: ry
07-05-18 JAC Cn
Z
07-25-18 KLH O
08-23-18 KLH U
10-19-18 DWR
O
u_
0
w
Al 00 U)
I --
O
z
AREAS
367
SQ. FT.
1 ST FLOOR
1969
2ND FLOOR
1679
TOTAL LIVING
3648
COVERED PORCH
367
ENTRY
111
GARAGE
570
2ND FLR COVERED
PORCH
84
TOTAL NON -LIVING
1132
TOTAL UNDER ROOF 1 4780
VOLUMES
ABV
CUBIC FT.
1ST FLOOR
20280
2ND FLOOR
15651
TOTAL VOLUME
35931
NOTE TO FRAMER:
REFER TO STRUCTURAL ENGINEERING
DRAWINGS FOR ALL EXTERIOR WALL
STUD SPECIES, SIZES AND SPACING.
NOTE TO CONTRACTOR:
INSTALL ALL HOUSEWRAP, WINDOW
AND DOOR FLASHING, TAPING AND
SEALANTS PER MFR WRITTEN
INSTRUCTIONS
ABBREVIATIONS LEGEND
ABV
ABOVE
AC
AIR CONDITIONER
AFF
ABOVE FINISHED FLOOR
AHU
AIR HANDLER UNIT
BLK
BLOCK
CABS
CABINETS
CLG
CEILING
CHR
CHAIR RAIL
COFF
COFFERED
COL
COLUMN
COND
CONDENSER
CRN
CROWN MOULDING
CVAC
CENTRAL VACUUM SYSTEM
DBL
DOUBLE
DIAG
DIAGONAL
DR
DOOR
DRY
DRYER
DW
DISHWASHER
EB
EYEBROW
FL
FLOOR LINE (MAT. CHANGE)
FLR
FLOOR
FP
FIREPLACE
FXD
FIXED
FXT
FIXTURE
GLS
GLASS
HB
HOSE BIB
KS
KNEE SPACE
LAV
LAVATORY
LT
LAUNDRY TUB
MRBL
MARBLE
MC
MEDICINE CABINET
MIR
MIRROR
MTL
METAL
OH
OVERHEAD
OPNG
OPENING
OPT
OPTIONAL
R & S
CLOTHES ROD and SHELF
REF
REFRIGERATOR
SD
SOAP DISH
SDLTS
SIDE LIGHTS
SGD
SLIDING GLASS DOOR
SH (2)
SHELVES (QUANITY)
SHWR
SHOWER
TB
TOWEL BAR
TPH
TOILET PAPER HOLDER
T&S
TUB and SHOWER
TEMP
TEMPERED
TR
TRANSOM
VOL
VOLUME
WC
WATER CLOSET
WD
WOOD
WH
WATER HEATER
WNCT
WAINSCOT
WS
WATER SOFTENER
WASH
WASHER
0
GENERAL NOTES:
PER FBC TABLE R-302.6 GARAGE SHALL BE
SEPARATED FROM RESIDENCE AND IT'S ATTIC W/
MIN. 12 GYP BOARD. HABITABLE ROOMS SHALL BE
SEPARATED FROM ROOM ABOVE W/ MIN %- TYPE
"X" GYP BOARD, WHERE THE SEPARATION IS A
FLOOR -CEILING ASSEMBLY. ANY STRUCTURE
SUPPORTING THE ASSEMBLY SHALL BE
PROTECTED W/ MIN %2' GYP BOARD.
i`
00
0 w
W O
1- O
;t, N
a- W N 00
W
0s�a
W Z 0
COQ
0 U
O wLL 0
ti
ao
12'-6"
@2018 TRUE DESIGN STUDIOS, INC.
0 0
W _ W
0 Q w
z Z 'O
W 0
(— J o
X Z
W
• PER FBC R302.5 NO OPENING IARE PERMITTED TO
SLEEPING AREAS. ALL OPIGS SHALL HAVE
SOLID WOOD, INSULATED STEEL OR 20 MIN. FIRE
RATED DOORS NOT LESS THAN 1-3/8 INCHES
THICKNESS. ALL DUCTS IN THE GARAGE OR
PENETRATING THE WALL OR (:EILING
SEPARATING THE GARAGE AND DWELLING SHALL
BE CONSTRUCTED OF MIN. 26 GA. SHEET METAL, 1
INCH MINIMUM RIGID CLASS 0 OR 1 DUCT BOARD,
OR OTHER APPROVED MATERIAL AND SHALL
HAVE NO OPENINGS INTO THE GARAGE.
19'�I- 1 1/2"
• PER IRC R302.12 IN COMBUSTIBLE
CONSTRUCTION WHERE THERE IS USEABLE
SPACE BOTH ABOVE AND BELOW THE
CONCEALED SPACE OF A FLOOR/CEILING
ASSEMBLY, DRAFT STOPS SHALL BE INSTALLED
SO THAT THE AREA OF THE CONCEALED SPACE
DOES NOT EXCEED 1,000 SQUARE FEET. DRAFT
STOPPING SHALL DIVIDE THE CONCEALED SPACE
INTO APPROXIMATELY EQUAL AREAS AND
INSTALLED PER IRC R302.12
75'-0"
13'-6 1/2"
59'-9"
• PER FBC R-312.1 PORCHES, BALCONIES OR
RAISED FLOOR SURFACES LOCATED MORE THAN
30" ABOVE FINISHED FLOOR OR GRADE SHALL
HAVE GUARDS NOT LESS THAN 36" IN HEIGHT.
PER IRC R-312.1.3 OPEN SIDES OF STAIRS WITH A
TOTAL RISE OF MORE THAN 38" ABOVE FINISHED
FLOOR OR GRADE SHALL HAVE GUARDS NOT
LESS THAN 34" IN HEIGHT MEASURED VERTICALLY
FROM THE NOSING OF THE TREADS.
27'-1"
48" H SCREEN WALL W/ -\
HARDIE SIDING FINISH VENT GAS APPLIANCE
& DECOR CAP PER IN ACCORDANCE WITH NFPA
BLDR SPEC (TYP) AC COND AC COND MECH EQUIPMENT 54/ANSI Z223.1 OR PREVAILING
_ YARD PROVISIONS PER CODE
T-8" 4'-0" !4'-0" 4'-0" T-5 1/2" 4'-3 1 /2" �Py
-0" 2'-3 1 /2" 2'-6" 2'-5 1 /2" - 15'-7"
/ 0 (7
M =X=
cn=w=
o-
�
N O (0 0
N �-
M DO
=poi
0 o2tU-
o -
`R U')
coCD Q M
M o0
M =gym=
cn = LL
U.) = N io 2,-0„
N Q N O
CA °O
M
I (_''
9' CLG I
o
Ia)I
1 +' 1
I mi
101
I=I
I I
IQI
IQI
I HI
1161 DECOR SHIPLAP STORAGE
1 w I WALL PER
I=I OWNERS SPEC 12' CLG
I I SINK UC REF GRILL
rl
O
10'-6"
14'-6"
1st LEVEL FLOOR PLAN
4'-8'1 r'
HDR at
±9' AFF
E.
I
T T
5 SHS N
• PER FBC R-312.1.3 REQUIRED GUARDS ON OPEN
SIDES OF STAIRWAYS, RAISED FLOOR AREAS,
BALCONIES AND PORCHES SHALL HAVE
INTERMEDIATE RAILS OR ORNAMENTAL
CLOSURES WHICH DO NOT ALLOW PASSAGE OF A
SPHERE 4" OR MORE IN DIAMETER.
2'-9"
mm
20/20 FXD 20/20 FXD
WOw
20/20 FXD 20/20 FXD
LU
9'-0" H.H.
20/20 FXD 20/20 FXD
to
=12 OHO
U)wW
W
GAS _ 20/20 FXD
�WH
Z -J
a
W U W
9'-0" H.H. 9'-0" H.H.
LLLi x w
9'-0" H.H. 9'-0" H.H.
QI I
owl
00
cy
m v
'
L'
m l I
9'-0" H.H.
5'-4" 4'-6"
o I
?h
T-6"
HDR at
I I ±9' AFF
i I
i I
ILLI
- - - - -- - -
IQI
IQI
1z61 COVERED
IWI
LANAI
I I
I I 12' CLG
t I
STANDING Jja
I I
13'-10"
TUB jgV
IQI
N
oI
I (_''
9' CLG I
o
Ia)I
1 +' 1
I mi
101
I=I
I I
IQI
IQI
I HI
1161 DECOR SHIPLAP STORAGE
1 w I WALL PER
I=I OWNERS SPEC 12' CLG
I I SINK UC REF GRILL
rl
O
10'-6"
14'-6"
1st LEVEL FLOOR PLAN
4'-8'1 r'
HDR at
±9' AFF
E.
I
T T
5 SHS N
• PER FBC R-312.1.3 REQUIRED GUARDS ON OPEN
SIDES OF STAIRWAYS, RAISED FLOOR AREAS,
BALCONIES AND PORCHES SHALL HAVE
INTERMEDIATE RAILS OR ORNAMENTAL
CLOSURES WHICH DO NOT ALLOW PASSAGE OF A
SPHERE 4" OR MORE IN DIAMETER.
2'-9"
mm
20/20 FXD 20/20 FXD
WOw
20/20 FXD 20/20 FXD
10' CLG
9'-0" H.H.
20/20 FXD 20/20 FXD
to
=12 OHO
N
W
GAS _ 20/20 FXD
�WH
= ih
a
W U W
9'-0" H.H. 9'-0" H.H.
M
9'-0" H.H. 9'-0" H.H.
QI I
TEMP 9-0"H.H.
9-0" H.H.
N b) to
°p
m l I
9'-0" H.H.
HB
o I
?h
T-6"
48"W 'co2@30/80
Ia
- - - - -
- - - - -- - -
KS
FREE
STANDING Jja
rn
TUB jgV
oI
WET
W
OWNERS
I
Z
_
wJa
_ 2p
RECESSED
ROOM
o
1
1
12' CLG
M
1 o_ I
J
I
ILL
°
a
� J
BATHING AREA
10' CLG
v
O
1
=Uj 00
0 I
LUZ¢
14"D
Q
I
v 00
P O S
tyt
BENCH
('1
0
O. BATH
i
ED 4
iia 60
0
10' CLG N
10' CLG
5
------------
6'-10"
4'-8" 5'-7 1/2"
T-0LU
1/2" �
0\00
6'-6'
5'-0"
22'-1"
2
@ 20/80
"
- - -
- 0
FURR OUT WALL
AS NEEDED (TYP)/A'
II
FL
�O _
______________=;1===--------___=;
1 R & 1 S r -
OHC
rn
5 SHS
N
oo
I
`L
_
o ,
- ----
WOOD STEPS TO
I
SII
�`f.
X11
`' LL WASH DRY
GRADE PER CODE
50/80
0
SII
as 11
WIC
PWDR °\°°
,
�,
1 p
U
II
II
10' CLG
6'c90
LAUNDRY
-
10' CLG -
o I
b a - ��
_
10' CLG
o
I
1M V In
°O
`-
6'-10"
_
4'-8 15'-7
1/2"I x UI
11'-11"
`* 2` 2"
4'-5 1/2" 2'-5 1/2" T-8 1/2"
T-2"
4'-9"
-70
•
v
�'�
I----------------
N QJ
I)
1
--- I
05 05�
HALF WALL TO
I
MIR
`7 1 1R&1S
1R&1S
p
°\`b�,�
Q
UNDERSIDE OF
J
72"WOPNG------
- -
N.<-
STAIR
(HDR at ±,4'-8" AFF)
OHC
N
°'
N
I DINING
9'CLG
10' CLG
-
40"WIDE OPNG
--------
ol
UNDER STAT R
a
UC REF WINE - I M _ I % (HDR at 8' AFF) 0 _ 1
COOLER MI MI 10' CLG 10' CLG w w co Z STORAGE
191 (oI W/ 12" D BEAMS �O Q- _ = 4 5 6M 7 8 9 I10 SLP CLG
LINE OF DECOR vl 19 It LINE OF DECOR ���00 Z �- 3 - -
BEAM ABV (TYP) I I BEAM ABV (TYP) g� m m 2 42" HNDRL W/ BALUSTERS
-------- -- -- --- - ----
11' CLG �� N UP 01 ON 6"H KNEEWALL
- ---- --- ----- -- -- `I� 13'-91/2 -- -----t „
12' CLG. � � 6 4 112" 3'-6 4'-9" T-5 1/2"
(10
EXTEND 36"H COUNTERTOP a U- �� " w1%
d l 33" OVER 2x6 WALL BELOW 1 1 _ 1 to �� 30"Wx48 H z- FOYER
M) W/ WATERFALL EDGE PER MI c\II to 2"D NICHE 10 CLG (9Iio 28' CLG
T1 (01 rn 1 1� o (8'-0' H.H.) CJI(°
9 1/2' OWNER SPEC I
1 16'-4" 3'-0 1 /2" 7'-6" LO T-3" I"' v 5'-6" 2'-11 1 /2" U 5'-4" 6'-0"
iv 1 1 5 1 /2" 1, 10„
-- ---- - _----- --� -- `�- --- - ---- FL 2@26/80
Z o N b --
GREAT --='�----- - �,- - -
0 N 1 Z LL N ---N --- J z\I a)
0- LL r _ m III
to `L m
ROOM MI w_Z'I =1 MI N °'cn U)
- U') PANT LO 11
12' CLG I I v 2x6 WALL LLi; U w
o r--- o00 —1 wl 1 = v ; 10'CLG 11
W/ 12" D BEAMS d = 1 �1; O -
N" -o o f I I o- _
-- -- -- - -- -- -- - - - ---N 5SHS 5SHS OFFICE /
.KITCHEN } ti BEDROOM
co MANTLE PER 't m = 10' CLG � Q �F��c BATH 2 \g0 10'CLG
ml OWNER SPEC - - - - - - ILL 1 (o1 36" COOKTOP co W/ 12" D BEAMS Z U Fo m � 10' CLG LL
1 W/ HOOD ° (x° 9
_
C_4 _ ir
yw� 0
aw
BENCH04 �N - M BENDH OHC OHC a (9 MIR
ENTRY
WOw
10' CLG
-M
to
=12 OHO
N
W
�I
I
= ih
a
W U W
U- I
M
-
QI I
w
O U CD
N b) to
°p
m l I
LO -
COLO
o I
?h
T-6"
= I J
Ia
20/50 SH 60" NODI -VENTED 20/50 SH 18/56 SH 18/56 SH 20/50 SH 20/50 SH 20/50 SH
9'-0" H.H. 9'-0" H.H. 9'-0" H.H. 9'-0" H.H. 9'-0" H.H. 9'-0" H.H. 9'-0" H.H.
GAS FP TEMP
2'-91/2" 2'-0" lie 8'-4" 11 4 2'-0" 2'-0" T-111/2" 5'-8" 6-51/2" 4'-2" 4'-31/2" 1'-10" T-0"
11 �
11 �
11
4'-0" 1 17'-1 1/2" 16'-1" -- - 8'-5 1/2" 11 13'-10„
75'-0"
55'-6"
N
rn
M
00
zn
cV
CD
ti
0
4
NT
=N '0
WOw
U=
�H0
to
=12 OHO
w N O
W
9
= ih
a
W U W
ap
U=W0Q
Ln o
O U CD
N b) to
LL
N
5'4'
MUNI�Y pEVE1.OPME�'T
COM
APPR� v,�D
SCALE: %4" = V-0"
Q
0
LU
r�-
r
X
r
,,6*1\
r
z
O
0
tds w
z_
fre
true design studios Q-
4745 SUTTON PARK CT., SUITE 402
JACKSONVILLE, FLORIDA 32224 W
P 904.821.5200 F 904.992.8700
WWW.TRUEDESIGNSTUDIOS.NET —1
Q
U
U)
Q
z
0
U)
w
} r)
Aim LL
O
07
w
J
w
V
z
360 Corporate Way U)
Orange Park, FL 32073 z
www.dreamfindershomes.com
W
w
H
w
W Q
W 2 U
CnU O U)
In z Z ~
W O
0 0 O
J U) � o
W C/)
Q
N
ATLANTIC BEACH
COUNTRY CLUB O
LOT 136 p
O
DUVAL COUNTY/FL p
O
PROJECT NO: 0
2018.003342
DATE: 04-25-18 0
DRAWN: JAC 1-
CHKD: U
DWR �
REVISIONS:
f'-
07-05-18 JAC U)
z
07-25-18 KLH 0
08-23-18 KLH U
10-19-18 DWR w
0
0
w
Al 10
U)
O
z