Loading...
1596 Maritime Oak Dr RES18-0358 dwgs 12TYPICAL WINDOW FLASHING METHOD "A-1" (ASTM E 2112-01) WINDOW INSTALLATION (METHOD A-1) WEATHER RESITIVE BARRIER (WRB) APPLIED PRIOR TO THE WINDOW INSTALLATION. FLASHING APPLIED OVER THE FACE OF THE MOUNTING FLANGE. JAMB FLASHING APPLY CONT. SEAL TO THE MOUNTING FLANGES AT THE TOP (HEAD) AND SIDES (JAMBS) OF WINDOW. EXTEND SEALANT AT JAMBS 8 %2" ABOVE THE R.O. AT HEAD. EMBED JAMB FLASHING INTO SEALANT AND FASTEN IN PLACE. (FLASHING GOES OVER SEALANT). (3 SEAL THE WINDOW FRAME TO OPENING. APPLY A %" NOM. DIA. TO THE BACKSIDE (INTERIOR) OF THE WINDOW FLANGE, IN LINE WITH ANY PRE -PUNCHED HOLES OR SLOTS. / OJAMB FLASHING EXTEND JAMB FLASHING TO OVERLAP -- SILL FLASHING. EXTEND JAMB FLASHING 8 %2" ABOVE ROUGH OPENING AT HEAD. TUCK TOP OF JAMB FLASHING UNDER THE FLAP OF WRB AT THE HEAD. SEE DIAGRAM. 9" OO �5Iml= SECURE WRB AT HEAD FLASHING AT HEAD EXTENDS 1" BEYOND JAMB FLASHING. 07 HEAD FLASHING —EMBED BOTTOM OF THE HEAD FLASHING AGAINST THE PREVIOUSLY APPLIED SEALANT (FLASHING GOES OVER SEALANT). EXTEND HEAD FLASHING BEYOND EACH JAMB FLASHING. FASTEN IN PLACE. 0 INTERIOR VIEW OP LEFT CORNER OF WINDOW 35°�/ `SILL FLASHING \ 911(j)WEATHER RESISTANT BARRIER (WRB) (LINE) UTAT A 45 DEGREE ANGLE, CAREFULLY CUT THE BARRIER ON A DIAGONAL. GENTLY RAISE THE TOP EDGE OF THE BARRIER UP AND TAPE THE TOP CORNERS AND CENTER TO THE EXTERIOR WRB SURFACE ABOVE. STEPS: SEALANT SHIM AND ADJUST WINDOW TO ACHIEVE SQUARE, PLUMB, AND LEVEL CONDITION. USE CORROSION RESISTANT FASTENERS. FASTEN WINDOWS PER WINDOW MANUFACTURER SPECIFICATIONS (1 IN WATER SHEDDING FASHION, ® APPLY BEAD OF SEALANT AT w STARTING AT THE BASE OF THE APPROVED HOUSE WRAP HOUSE SIDE JAMBS. EXTEND 8 %2" 0 WALL & WORKING TOWARDS THE 05 APPLY JAMB FLASHING WITH WATERPROOF TAPE TOP, INSTALL THE WRB TO THE O 1X WOOD TRIM ~ FACE OF THE SHEATHING. © APPLY BEAD OF SEALANT AT HEAD (2 APPLY SILL FLASHING 70 APPLY HEAD FLASHING �3 APPLY BEAD OF SEALANT AT BACK ® REMOVE PREVIOUSLY APPLIED TAPE, a w OF WINDOW FLANGE & SET MANUF. ALLOWING WRB TO LAY FLAT OVER HARDIE-SOFFIT® WINDOW USING PAN HEAD SCREWS HEAD FLASHING. APPLY NEW 5/8" SHEETROCK TO FACILITATE INSPECTION. DBL 2x TOP PLATE W/ SHEATHING TAPE OVER DIAGONAL APPROVED HURRICANE ANCHOR AT ENDS OF EACH CUT - SEE DIAGRAM. SECTION A THROUGH WINDOW JAMB SEALANT BEAD BEHIND MOUNTING FLANGE. SEALANT BEAD BETWEEN FLASHING AND MOUNTING FLANGE. FLASHING T EXTERIOR DOOR FLASHING WRAP WRB INTO OPENING 45° CUT REMOVE BOTTOM WRB FLAP m - MODIFIED "I" CUT IN WRB INSTALL VULKUM AT THRESHOLD PER MFR. INSTRUCTIONS. INSTALL DOOR, SHIM DOOR TO LEVEL, PLUMB AND SQUARE DOOR IN OPENING. E@ Qi_: 10" 10" L� WRB I I I Lf�- APPLY HEAD FLASHING, EXTENDING 10" BEYOND DOOR ROUGH OPENING. TEMPORARILY TAPE UP TOP FLAP h APPLY JAMB FLASHING TO BOTH SIDES OF DOOR FROM DOOR FRAME TO WRB, EXTENDING 8 1/2" ABOVE DOOR ROUGH OPENING. 1 _JL_� WRBI I I I UNFOLD TOP FLAP AND COVER DIAGONAL CUT IN WRB WITH SHEATHING TAPE. NOTE: ALL FLASHING WILL BE SELF ADHERING AND ROLLED SMOOTH & FLAT WITH A J -ROLLER TYPICAL DOOR FLASHING HEADER FOAM INSULATION DOOR FRAME PER DOOR MANUF. WEATHER STRIPPING PER DOOR MANUF. THRESHOLD AND WEATHER STRIPPING PER DOOR MANUF. INSTALL "Z" FLASHING OVER 1X TRIM IF DOOR IS NOT COVERED WITH OVERHANG OR PORCH -EXTERIOR FINISH C O.S.B.. w ZZ FLASHING (WHERE APPROVED HOUSE WRAP HOUSE � 0 WRAP DOWN TO DOOR FRAME SEAL w o WITH WATERPROOF TAPE w O 1X WOOD TRIM ~ LU CAULK Q 0 W/ 1/2" CLIPS DOOR STOP PER DOOR MANUF. Uj METAL DRIP EDGE WEATHER STRIPPING PER DOOR a w O MANUF. HARDIE-SOFFIT® HOLD 1/4" OFF CONCRETE CAULK UNDER THRESHOLD WITH NON -HARDENING WATERPROOF CAULK STEP DOWN TO OUTSIDE SURFACE TYPCIAL ROOF FLASHING A 2 3/4" B C U') bo N T � NT- CN N N 5" 3/8" or 5/8" 26 GA. GALVANIZED 26 GA. GALVANIZED 32 GA. GALVANIZED 2 1/2" MTL DRIP EDGE 5 X 5 ANGLE FLASHING "Z" FLASHING Q w ti X z O tds 0 W F - Z_ w true design studios 12- 4745 SUTTON PARK CT., SUITE 402 LL JACKSONVILLE, FLORIDA 32224 W P 904.821.5200 F 904.992.8700 WWW.TRUEDESIGNSTUDIOS.NET U U) W ir Q z (D U) O O LO U) W Q Cn CD Z Q O 360 Corporate Way CD Orange Park, FL 32073 Z www.dreamfindershomes.com ryQ 0 W W 2 J Se W Q w C) Cn c) O d. Z = 0 W z Deo O __.! W 1.- o Q cr- N ATLANTIC BEACH COUNTRY CLUB O LOT 136 p O DUVAL COUNTY/FL p O O PROJECT NO: 2018.003342 O DATE: 04-25-18 0 oRAwN: JAC I— CHKD: U DWR � REVISIONS: 07-05-18 JAC 07 z 07-25-18 KLH 0 08-23-18 KLH U 10-19-18 DWR IY O LL w A500 U) O z C -26 GA. GALVANIZED "Z" ZZ FLASHING (WHERE EXTERIOR BUILDING PANELS JOIN HORIZONTALY) B 26 GA. GALVANIZED 5 X 5 ANGLE FLASHING (WHERE 12 SEE CHIMNEYS AND WALLS MEET FIBERGLASS SHINGLES ELEV� ROOF) ON 15# FELT OVER O.S.B. W/ 1/2" CLIPS 2X6 FASCIA 26 GA. A GALVANIZED 2 1/2" PRE-ENGINEERED METAL DRIP EDGE TRUSSES @ 24" O.C. INSULATION PER CODE VENTED HARDIE-SOFFIT® 1/2" CEILING BOARD or 5/8" SHEETROCK DBL 2x TOP PLATE W/ APPROVED HURRICANE ANCHOR AT ENDS OF EACH TRUSS 24" WIDE 26 GAUGE ROLL VALLEY FLASHING AT ALL VALLEYS A 2 3/4" B C U') bo N T � NT- CN N N 5" 3/8" or 5/8" 26 GA. GALVANIZED 26 GA. GALVANIZED 32 GA. GALVANIZED 2 1/2" MTL DRIP EDGE 5 X 5 ANGLE FLASHING "Z" FLASHING Q w ti X z O tds 0 W F - Z_ w true design studios 12- 4745 SUTTON PARK CT., SUITE 402 LL JACKSONVILLE, FLORIDA 32224 W P 904.821.5200 F 904.992.8700 WWW.TRUEDESIGNSTUDIOS.NET U U) W ir Q z (D U) O O LO U) W Q Cn CD Z Q O 360 Corporate Way CD Orange Park, FL 32073 Z www.dreamfindershomes.com ryQ 0 W W 2 J Se W Q w C) Cn c) O d. Z = 0 W z Deo O __.! W 1.- o Q cr- N ATLANTIC BEACH COUNTRY CLUB O LOT 136 p O DUVAL COUNTY/FL p O O PROJECT NO: 2018.003342 O DATE: 04-25-18 0 oRAwN: JAC I— CHKD: U DWR � REVISIONS: 07-05-18 JAC 07 z 07-25-18 KLH 0 08-23-18 KLH U 10-19-18 DWR IY O LL w A500 U) O z CONTINUOUS STARTER STRIP OVER FLASHING INSTALLED PER MANUF WRITTEN SPECS MTL DRIP FLASHING W/ HEMMED EDGE SET IN CONT BED OF SEALANT SILL PLATE FIBERCEMENT LAP SIDING — OVER APPROVED HOUSEWRAP INSTALLED PER MANUF WRITTEN SPECIFICATIONS EXTEND HOUSEWRAP E OVER NAILING FLANGE MTL DRIP FLASHING W/ HEMMED EDGE SET IN CONT BED OF SEALANT HEADER (RE: STRUCT DWGS) 2x2 OVER 5/4x6 FIBER CEMENT - EXTEND 12" SELF -ADHERING — iILL SEAL MEMBRANE FLASHING OVER WINDOW FLANGE SET IN CONT BED OF SEALANT MTL DRIP FLASHING W/ HEMMED EDGE SET IN CONT BED OF SEALANT 02015 TRUE DESIGN STUDIOS INC. SCALE: 1Y2" = 1'-0" 2x6 PT (RIP TO 5" NOP"' 4x4 PT POST (RE: STRUCT DWGS) 5 A501 U COLUMN FRAMING %4x8 TRIM (RIP TO 7" NOM)(TYP) Y" SHTHG (TYP) 2x4 PT 02015 TRUE DESIGN STUDIOS INC. SCALE: 1Y2" = 1'-0" WINDOW HEAD 02015 TRUE DESIGN STUDIOS INC. SCALE: 1Y2" = 1'-0" 6 � RAILING 2x4 HANDRAIL (SLP TOP) 2x4 TRIM DECOR BALUSTERS PER BLDR SPEC 2x4 BOTTOM RAIL A501 % 02015 TRUE DESIGN STUDIOS INC. SCALE: 1Y2" = 1'-0" FIBERCEMENT LAP SIDING — OVER APPROVED HOUSEWRAP INSTALLED PER MANUF WRITTEN SPECIFICATIONS CONTINUOUS BEAD OF SEALANT at PERIMETER 5/4x6 FIBER CEMENT EXTEND HOUSEWRAP OVER WINDOW FLANGE SET IN CONTINUOUS BED OF SEALANT Y4" JOINT W/ BACKER ROD & SEALANT WINDOW JAMB 02015 TRUE DESIGN STUDIOS INC. SCALE: 1)/2" = 1'-0" CERAMIC TILE to i trvu NUU�tVVKAt OVER WINDOWSILL Y4" JOINT W/ BACKER ROD & SEALANT 5/4x6 FIBER CEMENT (SLP TOP) FIBERCEMENT LAP SI OVER APPROVED HO INSTALLED PER MANI WRITTEN SPECIFICAI WINDOW SILL 02015 TRUE DESIGN STUDIOS INC. WALL ASSEMBLY SCALE: 1Y2" = 1'-0" VINYL/WOOD/FIBER CEMENT SIDING (INSTALLED IN ACCORDANCE WITH CLADDING MANUFACTURER'S INSTALLATION RECOMMENDATIONS) ZIP SYSTEMS @ SHEATHING WOOD OR LT. GA. METAL STUDS. "I - CERAMIC TILE INSTALLED OVER "THIN -SET" ADHESIVE OVER MIN. 1/2" DensShield OR EQUIV. SKID RESISTANT FLOOR TILE INSTALLED OVER "THIN -SET" ADHESIVE ON MIN. 1 1/2" CEMENTITIOUS MUD SET -SLOP TO DRAIN (MIN 1" THICK AT DRAIN) WATERPROOFING NOTE: INSTALL JOINT MESH IN CORNERS AND SEAMS OF WALL BOARDS WITH "HYDROGUARD" WATER PROOFING OR EQUIV. COVER ALL SCREW HOLES AND PENETRATIONS WITH WATERPROOFING CAULK ALL CORNERS & JOINTS OF DISSIMILAR MATERIALS. RECESSED SHOWER DETAIL 1/8" GAP RECOMMENDED AT PANEL EDGES ZIP SYSTEM ® TAPE (INSTALLED OVER ALL JOINTS IN ZIP SYSTEM SHEATHING.) OVERLAP TAPE A MINIMUM OF 1" AT ALL T -JOINTS 1/8" GAP RECOMMENDED AT PANEL EDGES FASTEN ZIP SYSTEM ® SHEATHING AS REQUIRED BY - ENGINEER -OF -RECORD AND/OR LOCAL BUILDING CODE ZIP SYSTEMS O SHEATHING WITH LAP SIDING AT SLAB ON GRADE These construction details are provided to assist in the installation of Zip System ® product(s) and may not apply to every situation. Manufacturer accepts no responsibility or liability for the use of these or other construction details. tds O Q W Z w true design studios a- 4745 SUTTON PARK CT., SUITE 402 LL JACKSONVILLE, FLORIDA 32224 W P 904.821.5200 F 904.992.8700 WWW.TRUEDESIGNSTUDIOS.NET --� Q U U) Q W I— W W Q W V z Q Q 360 Corporate Way 07 CD Orange Park, FL 32073 z www.dreamfindershomes.com Q W W I -- W W U W c) o U) z z 0 w z mooO J w � Q Q ce- N ATLANTIC BEACH COUNTRY CLUB O LOT 136 p O DUVAL COUNTY/FL p O O PROJECT NO: O 2018.003342 z DATE 04-25-18 Q DRAWN: JAC H CHKD: DWR U REVISIONS: F- 07-05-18 JAC W z 07-25-18 KLH 0 08-23-18 KLH U 10-19-18 DWR w O LL Q W W A501 W F_ O Z Q z W w LL O Q lid W W Q W V z Q Q 360 Corporate Way 07 CD Orange Park, FL 32073 z www.dreamfindershomes.com Q W W I -- W W U W c) o U) z z 0 w z mooO J w � Q Q ce- N ATLANTIC BEACH COUNTRY CLUB O LOT 136 p O DUVAL COUNTY/FL p O O PROJECT NO: O 2018.003342 z DATE 04-25-18 Q DRAWN: JAC H CHKD: DWR U REVISIONS: F- 07-05-18 JAC W z 07-25-18 KLH 0 08-23-18 KLH U 10-19-18 DWR w O LL Q W W A501 W F_ O Z NOTE: ALL PERMANENTLY INSTALLED INTERIOR AND EXTERIOR LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH EFFICACY LAMPS AS PER FBC R404.1 ©2018 TRUE DESIGN STUDIOS, INC. rwvvr_ uvvry 1 crx WP GFI 1st LEVEL ELECTRICAL PLAN SCALE: %4" = 1'-011 0 0 tds w Z true design studios 4745 SUTTON PARK CT., SUITE 402 LL JACKSONVILLE, FLORIDA 32224 w P 904.821.5200 F 904.992.8700 J WWW.TRUEDESIGNSTUDIOS.NET Q U) 0 w Q z 0 U) w U- 0 O LO w Q U 07 U z Q 360 Corporate Way (n C9 Orange Park, FL 32073 z www.dreamfindershomes.com Q w 07 w H w J w U C) � o F_ I z = 0 w z Zoo0 ._.J w � o Q N ATLANTIC BEACH COUNTRY CLUB O LOT 136 p O DUVAL COUNTY/FL p O O PROJECT NO: Q 2018.003342 z DATE: 04-25-18 0 DRAWN: JAC I— CHKD: DWR Z) REVISIONS: H 07-05-18 JAC Cn z 07-25-18 KLH 0 08-23-18 KLH U 10-10-18 DWR 0 LL W El 00 U) 0 z ELECTRICAL LEGEND SWITCH TV OUTLET THREE-WAY SWITCH OS� SPEAKER $3 FOUR-WAY SWITCH THERMOSTAT a $R RHEOSTAT SD SMOKE DETECTOR DUPLEX *CM CARBON MONOXIDE DETECTOR [� AFCI DUPLEX CEILING LIGHT GFCI DUPLEX RECESSED CEILING LIGHT COUNTERTOP DUPLEX RECESSED EYEBALL LIGHT CT SWITCHED DUPLEX ALL HUNG LIGHT W d) 220 VOLT OUTLET EYEBALL LIGHT 220 6 LANDSCAPING LIGHT QUADRUPLEX CLNG 8 CEILING DUPLEX FLOODLIGHT FLOOR FLOOR DUPLEX VENT JUNCTION VENT AND LIGHT DB DOOR BELL HEAT AND LIGHT GO GARAGE DOOR 0 HEAT AND VENT PH PHONE OUTLET ®c HEAT, VENT AND LIGHT NOTE: ALL PERMANENTLY INSTALLED INTERIOR AND EXTERIOR LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH EFFICACY LAMPS AS PER FBC R404.1 ©2018 TRUE DESIGN STUDIOS, INC. rwvvr_ uvvry 1 crx WP GFI 1st LEVEL ELECTRICAL PLAN SCALE: %4" = 1'-011 0 0 tds w Z true design studios 4745 SUTTON PARK CT., SUITE 402 LL JACKSONVILLE, FLORIDA 32224 w P 904.821.5200 F 904.992.8700 J WWW.TRUEDESIGNSTUDIOS.NET Q U) 0 w Q z 0 U) w U- 0 O LO w Q U 07 U z Q 360 Corporate Way (n C9 Orange Park, FL 32073 z www.dreamfindershomes.com Q w 07 w H w J w U C) � o F_ I z = 0 w z Zoo0 ._.J w � o Q N ATLANTIC BEACH COUNTRY CLUB O LOT 136 p O DUVAL COUNTY/FL p O O PROJECT NO: Q 2018.003342 z DATE: 04-25-18 0 DRAWN: JAC I— CHKD: DWR Z) REVISIONS: H 07-05-18 JAC Cn z 07-25-18 KLH 0 08-23-18 KLH U 10-10-18 DWR 0 LL W El 00 U) 0 z NOTE: ALL PERMANENTLY INSTALLED INTERIOR AND EXTERIOR LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH EFFICACY LAMPS AS PER FBC R404.1 2nd LEVEL ELECTRICAL PLAN ©2018 TRUE DESIGN STUDIOS, INC. I I I I I ELECTRICAL LEGEND Z SWITCH Tv TV OUTLET THREE-WAY SWITCH 0 SPEAKER $3 FOUR-WAY SWITCH r -- I I THERMOSTAT 4 $R RHEOSTAT 3D SMOKE DETECTOR � i I DUPLEX *Cm CARBON MONOXIDE DETECTOR AFCI DUPLEX CEILING LIGHT r It GFCI DUPLEX J RECESSED CEILING LIGHT COUNTERTOP DUPLEX RECESSED EYEBALL LIGHT (4CT SWITCHED DUPLEX WALL HUNG LIGHT 6 220 VOLT OUTLET EYEBALL LIGHT 220 6 LANDSCAPING LIGHT QUADRUPLEX CLNG CEILING DUPLEX FLOODLIGHT FLOOR FLOOR DUPLEX VENT JUNCTION ®° VENT AND LIGHT D8 DOOR BELL 070 HEAT AND LIGHT GO GARAGE DOOR ®0 HEAT AND VENT P N° PHONE OUTLET HEAT, VENT AND LIGHT NOTE: ALL PERMANENTLY INSTALLED INTERIOR AND EXTERIOR LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH EFFICACY LAMPS AS PER FBC R404.1 2nd LEVEL ELECTRICAL PLAN ©2018 TRUE DESIGN STUDIOS, INC. I I I I I - -------------------- Z i I i I I I I I I I U� w 0 I I I r -- I I I I I I I I I i I I 1 I � z- 4 I I I I I I I I I I I I I I I I L--------------------------- � i I 1 n Yr X r Z 0 0 tds Z w true design studios 13- 4745 4745 SUTTON PARK CT., SUITE 402 LL JACKSONVILLE, FLORIDA 32224 P 904.821.5200 F 904.992.8700 w w WWW.TRUEDESIGNSTUDIOS.NET U U) 0 w h w J Q U Z _ Q 0 360 Corporate Way U) Orange Park, FL 32073 Z www.dreamfindershomes.com Q W U) wwT 1 w w Q �wC) U) 0 Z= 0 w z X00 0 � w E- � Q N ATLANTIC BEACH COUNTRY CLUB O LOT 136 p O DUVAL COUNTY/FL p O O PROJECT NO: O 2018.003342 z DATE: 04-25-18 0 DRAWN: JAC 1— CHKD: DWR CU REVISIONS: I- 07-05-18 JAC U) Z 07-25-18 KLH 0 08-23-18 KLH U 10-19-18 DWR 0 LL W SCALE: /4" = 1'-0" D El 01 cn F- 0 z Z I U� w 0 LL 0 4 o O Ln w J Q U Z _ Q 0 360 Corporate Way U) Orange Park, FL 32073 Z www.dreamfindershomes.com Q W U) wwT 1 w w Q �wC) U) 0 Z= 0 w z X00 0 � w E- � Q N ATLANTIC BEACH COUNTRY CLUB O LOT 136 p O DUVAL COUNTY/FL p O O PROJECT NO: O 2018.003342 z DATE: 04-25-18 0 DRAWN: JAC 1— CHKD: DWR CU REVISIONS: I- 07-05-18 JAC U) Z 07-25-18 KLH 0 08-23-18 KLH U 10-19-18 DWR 0 LL W SCALE: /4" = 1'-0" D El 01 cn F- 0 z