116-120 Jackson Rd RES18-0398&0397dwgs4ROOF VENTILATION
SCALE: 1/4"=V-0"
i Xr"i ia=si-i
SCALE: 1/4 I'-0"
SCALE: 1/4"=1'-0"
ALT 6HINGLE5 ON 5YNTNETIC FELT
:TURAL SHEATHING DECKING NAILED
NAILS 9 6" O.C. AT PANEL EDGES
E AND 4" O.0 AT COMPONENT AND
STRIP' 3 ON PREENGINEERED
ZDS, TYF.
`FENT FIBER 51DING ON 1i2"
'RUCTURAL SHEATHING ON
�.C. w/ R-13 BATT INSULATION,
FARING
V O.C. ON 5/1611 C.F.
VOM. ZIP 5NEATNING ON
5lp16"O.C.
E�E�-�pMEN�
a�
E
PREVISIONS)
DATE OF
ISSUE
11-30-18
DRAWN BY:
NGF
SHEET NO.
JACKSON
A-3
11028
jll II II II II II II II II II
III II II II II II II II II II
III i j I I 15TUD5 IN WALL BEYOhb
III II II II II II Il II 11 II
III II II II II 11 131-14" II II II
III 1113'-4•' II II 11 II
I I II II II II II �� II (I „NG II„ II
I I I 8 O LOz l LVL
I I II it II I II II � II II II
I II II I II II 4 II II
I II ll I II II ,4-4 II II II
I II 11 II --
-----
I = _ _ -=BOTTOM PL WAL 5EyO l� - _ _ _ _
TOP PL TE5 IN WALL BEYOND
— — — — — — — — —
PROVIDE COMPLIANT STAIR GUARD
RAILS, HANDR AND RAILS AT LANDINGS,
SEE FRC 8312.1 AN 122
RAILING SELECTIONS E BY OWNER
"
4" THICK 3000 PSI FIBER REINFORCED
CONCRETE SLAB ON 8 MIL PVC VAPOR
BARRIER ON 95% MODIFIED PROCTOR
COMPACTED FILL w/ TERMITE TREATMENT, TYP.
3 WALL 5 CT1®N
A-4 SCALE: 1/2"=I'-0"
4" THICK 3000 F
CONCRETE SLAB
BARRIER ON 959,
COMPACTED FILL
SIMP50N 4" SDWC
SCREWS v EA. STUD
51MRSON 6" 5DWC
6CREW5 9 8" O.C.
16" LVL
51MRSON 6" 5DWC
SCREWS is EA. STUD
4 WALL SCf ON
-4 SCALE: 1/2"=i'-0"
OPTIONS
3 UJALL SECTION
A-4 5CALE:1/2"=P-0"
BEARING
OPTIONS OPTIONS
5UILIDiN 5 CTION
A - 4 SCALE: I/2": i'-0"
(RREVISIONNS
DATE OF
ISSUE
II -30-18
DRAWN BY:
HGP
r SHEET NO. 1
JACKSON
A-4
I,m28
ZO
U
cMn
U
W
N
asy
on
tit
x
t�
x
a-,
�
U W
F
U
W
Q
�
�
Q
DATE OF
ISSUE
II -30-18
DRAWN BY:
HGP
r SHEET NO. 1
JACKSON
A-4
I,m28
i,
c
1-41/2" SIMPSON SDWC
SCREWS a EA.
OUTRIGGER
SEE �/4-5
140" SIMP50N 5DWC —
SCREW5 0 EA. ROOF
TRUSS
4 5RACKET _
A-5 SCALE: 3/4'4.0"
8"Xi/4" LAG SCREW
10"X1/4" LAG SCREW
4x8 *1 SYR BEAM
6"X1/4" LAG SCREW
12"X'/4" LAG SCREW
"HIGH WIND" ASPHALT SHINGLES ON SYNTHETIC FELT
ON 1/2" NOM, STRUCTURAL SHEATHING DECKING NAILED
w/ 6d RING SHANK NAILS to 6" O.C. AT PANEL EDGES
AND INTERMEDIATE AND 4" O.0 AT COMPONENT AND
CLADDING EDGE STRIP * 3
2411
3/4" TEG ADVANTEX PLYWOOD DECK
GLUED AND NAILED TO
PREENGINEERED FLOOR TRUSSES S
16" O.G., TYP.
a 2411
3-16d NAILS- � 3-I6d NAILS
INTERIOR SHEAR WALL, NOM,
STRUCTURAL SHEATHING NAILED AND
BLOCKED w/ 8d NAILS e b" O.C. ONE
SIDE AND 1/2" GWB BOTH SIDES
INTIC FR 5HAUJALL 5FRAGING
SCALE: 1/2"=1'-0"
14o" SIMPSON SDWC
SCREWS is EA. ROOF
TRUSS
BEDROOM
"HIG1H, WIND" ASPHALT SHINGLES ON SYNTHETIC FELT
ON y2" NOM. STRUCTURAL SHEATHING DECKING NAILED
w/ 8d RING SHANK NAI,_S 9 6" O.C. AT PANEL EDGES
AND INTERMEDIATE AND 4" O.0 AT COMPONENT AND
CLADDING EDGE STRIP * 3
3/4" T4G ADVANTEX PLYWOOD DECK 6" EXPOSURE HARDI ARTISEN 34" T46 ADVANTEX PLYWOOD DECK
GLUED AND NAILED TO CEMENT FIBER SIDING w/ MITERED GLUED AND NAILED TO
PREENGINEERED FLOOR TRUSSES a CORNERS ON HOU5EWRAP PREENGINEERED FLOOR TRUSSES 9
16" O.C., TYP. SECOND FLOOR _
16" O.C., TYP.
I -0 2'
GARAGE
O
SEE STRUCTURAL DRAWINGS
FOR HOLDDOWIN SYSTEM
OPTIONS
UJALL 5ECTICN
(o
S-2
STRUCTURAL
BRACKETS
3-12" LVL PART OF SPEAR FRAME,
SEE i/S-2
O.N. DOOR
LIVING ROOM
I'-411
6" EXPOSURE CEMENT FIBER
SIDING ON 1/2" NOM. ZIP -WALL
STRUCTURAL SHEATHING ON 2x4
STUDS a 16" O.G. w/ R-21 BATT
INSULATION, GWB INTERIOR
SECOND FLOOR
4" THICK 3000 PSI FIBER REINFORCED
CONCRETE SLAB ON 6 MIL PVC VAPOR
BARRIER ON 95% MODIFIED PROCTOR
COMPACTED FILL w/ TERMITE TREATMENT, TYP.
3
S-2
u�
GA5LE ENI) BRACING [DETAIL
SCALE: 1/2"=11-0"
Ix2 BATTENS 6 16" O.C. ON
5116" Cr-. PANELS ON 1/2l'
NOM. ZIP SHEATHING ON 2x4
WOOD STUDS a 16" O.G.
LANAI
.2x4 OUTRIGGERS tv
�).C. ON TOP CHORD OF
,LF TRUSS.
IMP50N H2.5A w/ 5-10d x I1/2" TO
RIGGER 4 5-10d x 11/2" TO EA.
SLE TRUSS,
IMP50N H2.5A w/ 5-10d x I1/2" TO
_RAL BRACE 4 5 -10d x 11/2" TO
SABLE TRUSS,
IMP50N MSTA9 w/ 8-10d 9 4611
"HIGH WIND" ASPHALT SHINGLES ON SYNTHETIC FELT
ON /z" NOM. STRUCTURAL SHEATHING DECKING NAILED
w/ Sd RING SHANK NAILS e 6" O.G. AT PANEL EDGES
AND INTERMEDIATE AND 4" O.0 AT COMPONENT AND
CLADDING EDGE STRIP * 3
4" THICK 3000 PSI FIBER REINFORCED
CONCRETE SLAB ON 8 MIL PVC VAPOR
BARRIER ON 9536 MODIFIED PROCTOR
COMPACTED FILL w/ TERMITE TREATMENT, TYP,
3 LUALL 5 CTICN
a-5 5C-ALE:I/2"=I'4"
1'-411
FIRST FLOOR
o�
d1
12
"HIGH WIND" ASPHALT SHINGLES ON SYNTHETIC FELT
ON 1/2" NOM. STRUCTURAL SHEATHING DECKING NAILED
w/ 8d RING SHANK NAILS a 6" O.G. AT PANEL EDGES
AND INTERMEDIATE AND 4" 0,C AT COMPONENT AND
CLADDING EDGE STRIP * 3
11 All
SEE STRUCTURAL DRAWINGS
FOR HOLDDOWN SYSTEM
OPTIONS
)BUILDING 5CTICN
SCALE: 1/2"=1' -011
IONS
EDGE OF ROUGH OPENING
SEALANT, TAPE OR LIQUID 112" GWB
OPENINGS PERIMETER SEALANT INSTALLATION
FINISHED ELEVATION
V4'x3%" CF. TRIM
WINDOW
Wx6" Cr-. TRIM
WINDOW INFALLATION
I ROGEDU E
I. VERIFY THE OPENING IS PLUMB, LEVEL AND SQUARE.
2. VERIFY THE WINDOW WILL FIT IN THE OPENING.
3. APPLY COMPATIBLE LIQUID SEALANT OR TAPE AT
PERIMETER OF OPENING TO COMPLY WITH MPGR.
INSTRUCTIONS.
4. INSTALL SILL SHIMS AS REQUIRED BY WINDOW
MANUFACTURER.
5. INSERT WINDOW IN OPENING AND SHIM, LEVEL AND
FASTEN AS REQUIRED BY WINDOW MANUFACTURER
6. APPLY SIDE FLASHING TAPE OR LIQUID SEALANT
ALL AROUND -
1. INSTALL G.F. TRIM AT SILL, JAMBS AND HEAD, (NO
45° MITERS)
8. INSTALL HEAD FLASHING.
CAULKIN
CAULKin
X1/2" GWB
CAULKI�
i2" GWB
HEAD
- I•
5ILL
%" NOM ZIP STRUCTURAL SHEATHING
Cr-. 51DING w/ 11/4" LAP
DO NOT SEAL
ALUMINUM FLASHING:
5/4" x 31/2" C.F. TRIM
DO NOT SEAL
WINDOW
SUR
SEALANT, TAPE OR LIQUID
SEALANT
5/4" x 3%" C.F. TRIM
SEALANT
1/2" NOM ZIP STRUCTURAL SHEATHING
WEATHER BARRIER, CONT.
�;F. SIDING w/ 11/4" LAP
WINDOW
SEALANT, TAPE OR LIQUID
5/4" x 6" Cr-, TRIM
SEALANT
11/2" NOM ZIP STRUCTURAL 5WEAT14ING
:;F. SIDING w/ 11/4" LAP
WINDOW IN5TALLATION a HA IDI FLANK
SCALE: 3"--1'-0"
- lEAVE FL45HIN , T�F
\,4-�o% SCALE: 3"=1'-O"
�••�' (GABLE FLASHING SIM.)
INSTALL CONT. AT ALL EAVE AND GABLE
LOCATIONS
JRAL PANEL ROOF DECK
14DERLAYMENT
HINGLE5
METAL DRIP ON P.T, Ix2 ON 2x6
FASCIA, TYP. ALL LOCATIONS
ROOF - WALL FL45HNG, TSF,
SCALE: 3"=I' -O"
INSTALL CONT, AT ALL ROOF TO WALL
LOCATIONS INCLUDING ALL SIDE WALLS AND AT
CHIMNEY
OOF - WALL FLA54N , TSF.
SCALE: 3"=I' -O"
INSTALL CONT, AT ALL SLOPED ROCS TO WALL
LOCATIONS INCLUDING ALL WINDOW SILLS
HING
F DECK
m
(REVISIONS)
S
DATE OF
ISSUE
II -30-I8
DRAWN BY:
HGP
SHEET NO.
JACKSON
A-6
11028 J
O
�+
u
m
W
C/1
N
m
P
U
H
uW
p�
¢ W
W
w
Q
DATE OF
ISSUE
II -30-I8
DRAWN BY:
HGP
SHEET NO.
JACKSON
A-6
11028 J