Loading...
133 Beach Ave. RES18-0376 dwgs1Q 10 z0 4,0 SCALE: 1" = 20' 0 n � > vi � W �N m C) 00 c w C-) 0 z 0 0 z I 0 0 r r Z m I I I I i p:0 I O {O �a N.N -.' J FOUND 3/PSM 6146 INT OF BEGINNING �^ :� NORTHING: 2178946.074 I PO ST CORNER OF LOT 2 - EASTING: 531301.888 NORTHWE OD tr n WOOD POWER I N I POLE I ELECTRIC METER BOX 16' PHONE RISER 51.22' TO C.C.C.L. WATER METER s9 15.49 x • 7 �6 0.5' \ WpOO WALL Z BACKFLOW rn i'A�R PREVENTER 19.6 COVERER BRICK D FLOOR{ I BRICK PAVER DRIVEWAY 8" SANITARY OVERHA G` SEWER VALVE \ DRIVEWAY r / 16.5' 27.4' 1 0 2ND FLOOR 3 0 ; L_ _ OVERHANG PORCH J COVERED P p o�? Oo I 2ND FLOOR DECK (n O 0 CONCRETE 3.9' DRIVEWAY cn o \ O 1 34 BRI�Kx 1gq RS 9 - 11.0' 15.46 X fTi m xti 0ti WATER METER x.30 �' 2 STORY BLOCK & T W vp m I W00D SHINGLE oW�) opo_ N , �i i 17-S F _RESIDE 5 - - 1� � =1 O 94 � I - -- I - FIN FLOOR -17-11 Gr > rm m o O QONCRETE � � O O D N TIARIVEWAY PROPANE 1* 2ND FLOOR TANKS 01 n T �^ I OVERHANG 27.4' �j.. 1 � NORTHING: 2178872.492 -{ \ 21.4, 1 FASTING: 531308.367 4 ' / 16g3�t IS00 < FOUND 1/2CAIRPONg367 , 15.35 WOOD 'POWER '�\ S i QS 1 g POLE \/6 . 02 FOUND 1/2" REBAR, CAP 52.$0 �O C.C.C.L. x 1 .S LB6794 (0.53' SW IY)S 15 x 5 0 rn D 0 .W$TER �S6 h. v A/C STEP m h� MvE.TERS I y P� 28.8' 0 2 c z ZCOQUINA DRIVE IV 2 STORY W i", Cn RAILROAD TIE I STUCCO n Z O I� BORDER RESIDENCE 0 Cw c° 109 v w o N No. p in FLOOR = 1 CABLE GARAGE FLOOR = 1 RISER N I 28.8' I 23.3' rTt v1 N Ov NI COQUINA DRIVE R BORT _I 53.62' BENCHMARK: - - - - FOUND MAGNAIL & DISK, LB3672 1.0' ELEVATION=15.42 (NAVD 1988) ASPHALT DRIVE _ .. _ .. N87 58'28"W 228.11' D.N.R. MONUMENT NO. A20 NORTHING: i2,181553.517 EASTING: 375084.004 NOTES: 1. THIS IS A BOUNDARY SURVEY. 2. NO BUILDING RESTRICTION LINE PER PLAT. THERE MAY BE RESTRICTION LINES OR EASEMENTS BY ZONING OR RECORDED IN THE PUBLIC RECORDS OF THIS COUNTY THAT AFFECT THIS PROPERTY THAT ARE NOT SHOWN ON THIS SURVEY. 3. BEARINGS ARE BASED ON THE COASTAL CONSTRUCTION CONTROL LINE AS RECORDED AUGUST, 1992 AND RECORDED IN MAP BOOK 'C' PAGES 72, 72A THROUGH 72H. 4. THE EROSION CONTROL LINE AS RECORDED IN PLAT BOOK 35, PAGES 59, 59A AND 59B OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA WAS ESTABLISHED AS THE SEAWARD BOUNDARY OF ALL OCEANFRONT PROPERTY IN DUVAL COUNTY BY FLORIDA STATUTES CHAPTER 161.191. 5. THE GENERAL PERMIT LINE IS SHOWN AS PER OFFICIAL RECORDS BOOK 12975, PAGE 1781 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. 6. BEARINGS AND DISTANCES WITH THE "DEED" LABEL ARE AS PER OFFICIAL RECORDS BOOK 17961, PAGE 1623 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA. 7. BENCHMARK USED IS FOUND MAGNAIL SOUTHWEST INTERSECTION OF 1 ST STREET AND OCEAN AVENUE IN EAST SIDE OF 11 " PALM. ELEVATION=12.40 (NAVD 1988) DATUM. 8. MEAN HIGH WATER LINE (MHW) BASED ON EXTENDED DATUM FOR TIDE STATION 872-0291, JACKSONVILLE BEACH. MHW = 2.1 N.A.V.D. (1988) WITH A TIDE RANGE OF 5.1 FEET 9. SEASONAL HIGH WATER LINE CALCULATED ACCORDING TO CHAPTER 16B-33.002(45), FLORIDA ADMINISTRATIVE CODE, MHW(2.1)+(1.5 X TIDE RANGE(5.1) = 8.25' THE PROPERTY SHOWN HEREON LIES IN FLOOD ZONES "X" (AREA OUTSIDE THE 0.2% ANNUAL CHANCE FLOOPLAIN), "AO" (DEPTH 2') AND "VE" (EL 16) AS WELL AS CAN BE DETERMINED FROM THE FLOOD INSURANCE RATE MAP No. 12031 CO409H, REVISED JUNE 3, 2013 FOR DUVAL COUNTY, FLORIDA. NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER." FIRST � STREET VARIABLE WIDTH RIGHT OF. WAY PAVED PUBLIC ROAD ( FORMERLY �IaaDONALD STREET) \ �o { o \ Flo { \ olm Zlo \ mi>< rn i \ D.N.R. MONUMENT NO. A21 NORTHING: 2,178371.217 EASTING: 375348.223 aecKeoBY: _IIFILE: 20�IIoR"�++er:�ll BOATWRIGHT LAND SURVEYORS, inc. 1500 OBERTS FOUND 1/2" IRON p*_3NO CAP X 12.5 X 14. x 9.7 , I I .1 x 9.2 { I I I I t II I 0 � 1.3.91 , X I I I I 1 I I I I I I I I I I I _o I II I I II I I Z I I I I 0 0 I I I I I 1 I 1 O I I I I N OD I 1 I I go i OD 0101 x cn po x 916 II II�ryO IX I -n 0 II 1 II Fn m 11 CLVI� I I i I / 1 1 1 \ I 1 I 1 1 1 1 1 1 1 1 1 \11 Iil 11 11 1 \ I II \ 11 II 1 l 1 t l 1 X 9.7 10.0 X1'10.8 x 13.8 X108 FOUND 1/2' IRON x IPIPE, NO CAP I IIco I / ISO I I00 �rn I� N I -P Cs1 �1 0.3' 0 FOUND 1/2' IRON I m{ 1 i v Z PIPE, CAP LB3672 K6.0 X 6.9 j A �Ix7.7 I j 13.9 I c tl X6.7 (! i �'� rn 0 � N D 0 IZ I Im I �0 D O % z I I O {z� 0WO 1 I I 1 p I I 1 IU,U'r I I a) O I_ I mm I � I 1 i MAP SHOWING SURVEY OF LOT 2, TOGETHER WITH A PART OF LOT 1, BLOCK 32, PLAT No. 1 SUBDIVISION "A" ATLANTIC BEACH AS RECORDED IN PLAT BOOK 5, PAGE 69 OF THE CURRENT PUBLIC RECORDS OF DUVAL COUNTY, FLORIDA; TOGETHER WITH THE LAND LYING EASTERLY THEREOF OUT TO THE EROSION CONTROL LINE AS RECORDED IN PLAT BOOK 35, PAGES 59, 59A and 598 OF SAID PUBLIC RECORDS; ALL MORE PARTICULARLY DESCRIBED AS FOLLOWS: FOR A POINT OF BEGINNING, COMMENCE AT THE NORTHWEST CORNER OF LOT 2; THENCE SOUTH 05'09'00" EAST, ALONG THE WEST LINE OF SAID LOTS, A DISTANCE OF 74.02 FEET TO A POINT 24.00 FEET SOUTHERLY OF THE NORTHWEST CORNER OF SAID LOT 1; THENCE NORTH 86'49'25" EAST, ALONG THE SOUTHERLY LINE OF THE LANDS DESCRIBED IN OFFICIAL RECORDS VOLUME 2855, PAGE 954, A DISTANCE OF 200.24 FEET TO THE EAST LINE OF SAID LOT 1 AT A POINT 36.00 FEET SOUTHERLY OF THE NORTHEAST CORNER OF SAID LOT 1; THENCE CONTINUE NORTH 86'49'25" EAST, A DISTANCE OF 47.48 FEET TO THE AFOREMENTIONED EROSION CONTROL LINE; THENCE NORTH 04'40'58" WEST, ALONG SAID EROSION CONTROL LINE, A DISTANCE OF 88.89 FEET TO AN INTERSECTION WITH THE EASTERLY PROJECTION OF THE NORTHERLY LINE OF AFOREMENTIONED LOT 2; THENCE SOUTH 83'23'18" WEST, ALONG SAID NORTHERLY LINE OF LOT 2 AND ITS EASTERLY PROJECTION, A DISTANCE OF 248.38 FEET TO THE POINT OF BEGINNING. 14.1 x6 0 � 1.3.91 , X O.41 i X 7.2 {I 1 X 6.7 I I I I 1 I I I { 1 1 I \\ {I I I I I I I / I m{ I I m{ 1 i v I I i K6.0 X 6.9 j a �Ix7.7 I j 13.9 I I 1 X1&41 tl X6.7 (! I Im I % z I I 1 VIII 1 I I 1 p I I 1 I I I D 11 I { I � I 1 i 1 1= { 1 I I I I SII I ( j I i l f l II 7 I y / I I I Il 2 1 II � I I I I I I 1 w I II 11 1 1 ! x6.21 x5.2 13.41 x 9'5 x 6.3 X 10.7 X 4.� I I I I I I I I I I I 1 I I I I I I I I I i I I I I X 3.7 i v I I I I I I I I I i I I I I I I I I I I I I i I I I I RIVE JACKSON ;;; VILLE BEACH, FLORIDA x 1.3 1 1 i I t I I 1 1 1 1 i 1 I 1 l I t 1 I 1 1 I i I I I I X 1.4 I I I I I I I I I I I I I I I X11.0 X 0.4 3x.7 I I 1 I I I I I X 0.3 I x -0.3 X -0.3 X -0.4 0 C) 1'i D Z THIS SURVEY WAS MADE OR THE BENEFIT OF WILLIAM C. SCROGINS. OFFICE COPY DONN- W:- ROATWRIGHT, P.S.M. FLA. LIC. SURVEYOR AND MAPPER No. LS 3295 FLORIDA LICENSED SURVEYING AND MAPPING BUSINESS No. LB 3672 DATE: SEPTEMBER 17, 2018_ SHEET , OF 1 (904)241-8550 DESIGN CRITERIA WIND PRESSURES (PSF) THE STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE 6TH EDITION. REFERENCE TO OTHER STANDARD SPECIFICATIONS OR CODES SHALL MEAN THE LATEST PUBLICATION. 100 SF FOUNDATIONS ARE DESIGNED FOR AN ASSUMED ALLOWABLE LOAD OF 2,000 PSF. +30.0 SUPERIMPOSED LIVE LOADS: +21.2 ROOFS AND CANOPIES: (REDUCIBLE)......................................................................................... 20 PSF FLOORS(REDUCIBLE).................................................................................................................... 40 PSF BALCONIES........................................................................................................................................ 40 PSF WIND LOADS: -60.9 ULTIMATEWIND SPEED.................................................................................................................. 130 MPH NOMINALWIND SPEED................................................................................................................... 103 MPH MEANROOF HEIGHT......................................................................................................................... 18 FT RISKCATEGORY............................................................................................................................... II WINDEXPOSURE............................................................................................................................... D ENCLOSURE CLASSIFICATION ................................................................................................... ENCLOSED INTERNAL PRESSURE COEFFICIENT............................................................................................ ± 0.18 DIRECTIONALITY FACTOR (Kd) ................................................................................................ 0.85 SHAPEFACTORS................................................................................................................................ PER CODE THIS BUILDING IS NOT LOCATED IN THE WIND BORNE DEBRIS REGION. IMPACT RESISTANT GLAZING IS NOT REQUIRED. +38.8 CONCRETE ALL CONCRETE PROPORTIONING, MIXING, TRANSPORTATION, PLACING, AND CURING SHALL CONFORM TO ACI 301. ALL CONCRETE SHALL BE LABORATORY DESIGNED AND CONTROLLED TO MEET THE REQUIREMENTS OF ACI 318 AND THE PROJECT'S DESIGN BUILDING CODE. USE OF CALCIUM CHLORIDE, CHLORIDE IONS, OR OTHER SALTS IN CONCRETE IS PROHIBITED. CONCRETE SHALL CONFORM TO THE FOLLOWING: F'c @ 28 DAYS TYPE AGGREGATE LOCATION W/C RATIO (MAX) 4,000 NORMAL WEIGHT SLAB -ON -GRADE 0.50 3,000 NORMAL WEIGHT FOOTINGS 0.55 3,000 NORMAL WEIGHT ALL OTHER CONCRETE 0.55 THE AIR CONTENT IN ALL CONCRETE EXPOSED TO WEATHER SHALL BE BETWEEN I % & 4%. CONCRETE PROTECTION FOR REINFORCEMENT SHALL BE AS NOTED BELOW, OR PER LATEST ACI 318 FOR CONDITIONS OTHER THAN THOSE LISTED: CONCRETE CAST AGAINST EARTH...........................................................3" BEAMS AND COLUMNS................................................................................1 1/2" SLABSON GRADE...........................................................................................2" FROM TOP FORMED CONCRETE EXPOSED TO EARTH OR WEATHER...................2" SLABS & WALLS NOT EXPOSED TO EARTH OR WEATHER.................I CHAMFER ALL EXPOSED CORNER 3/4" MINIMUM. ALL HOOKS CALLED FOR IN STRUCTURAL DRAWINGS SHALL BE ACI STANDARD HOOKS, UNO. REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60 UNO. ALL WELDED WIRE MESH SHALL CONFORM TO ASTM Al 85. LAP TWO SQUARES AT SPLICES. DO NOT WELD REINFORCING STEEL UNLESS APPROVED IN WRITING BY THE STRUCTURAL ENGINEER. TIE ALL REINFORCING STEEL AND EMBEDS SECURELY IN PLACE PRIOR TO PLACING CONCRETE. THE CONTRACTOR SHALL PROVIDE SUPPORTS TO MAINTAIN THE REQUIRED REINFORCING POSITION. "WET STICKING" DOWELS INTO CONCRETE IS NOT PERMITTED. THE CONTRACTOR SHALL COMPARE THE STRUCTURAL PLANS AND DETAILS WITH THE ARCHITECTURAL PLANS AND DETAILS AND REPORT ANY DISCREPANCIES TO THE ARCHITECT PRIOR TO THE COMMENCEMENT OF SHOP DRAWINGS. ALL REINFORCING SHALL BE LAPPED WITH ACI CLASS B SPLICE. MASONRY PROVIDE HOLLOW, LOAD BEARING CONCRETE MASONRY UNITS CONFORMING TO ASTM C90, TYPE I WITH A MINIMUM DENSITY OF 105 PCF. CMU SHALL HAVE A MINIMUM ASSEMBLY COMPRESSIVE STRENGTH (Fm) OF 2,000 PSI. THE 28 -DAY GROUT COMPRESSIVE STRENGTH SHALL BE 3,000 PSI MINIMUM. MORTAR SHALL BE TYPE "S" OR "M". LAP ALL REINFORCING 48 BAR DIAMETERS IN BOND BEAMS AND 72 BAR DIAMETERS IN VERTICAL WALL REINFORCING AND MASONRY BEAMS. ALL CMU WALLS SHALL BE LAID IN RUNNING BOND. STANDARD JOINT REINFORCING SHALL BE PROVIDED AT 16" OC VERTICALLY IN SUPPORTED WALLS. JOINT REINFORCING SHALL BE PROVIDED AT 8" OC VERTICALLY IN CANTILEVERED WALLS. JOINT REINFORCING TYPE SHALL BE SPECIFIED BY ARCHITECT. UNLESS NOTED OTHERWISE ON PLAN SHEETS, REINFORCE ALL EXTERIOR AND LOAD BEARING CMU WALLS W/ A #5 FULL HEIGHT VERTICAL BAR CENTERED IN WALL AT 24" OC, ADDITIONALLY, PROVIDE A #5 VERTICAL FULL HEIGHT AT EACH WALL END AND CORNER. SEE TYPICAL CMU REINFORCING DETAIL FOR OTHER REINFORCING REQUIREMENTS. ALL CMU CELLS RECEIVING REINFORCING SHALL BE GROUTED SOLID. UNLESS PROVIDED ON ARCHITECTURAL DRAWINGS, PROVIDE VERTICAL CONTROL JOINTr AT A MAXIMUM SPACING OF 25'-0" OC. JOINTS SHOULD NOT BE PLACED WITHIN 5'4" FROM BUILDING CORNERS AND NOT CLOSER THAN 1'-4" TO OPENING EDGES AND MAJOR BEAM OR,; JOIST BEARING LOCATIONS. CONTRACTOR SHALL SUBMIT JOINT LAYOUT TO ARCHITECT FOR APPROVAL IF JOINT LOCATIONS ARE NOT SHOWN ON ARCHITECTURAL DRAWINGS. BOND BEAMS, CMU LINTELS, MASONRY BENEATH STEEL BEAM AND JOIST BEARINGS, AND OTHER STRUCTURAL ELEMENTS SHALL EXTEND UNINTERRUPTED ACROSS CONTROL JOINTS. FILL ALL CELLS BELOW FINISHED GRADE. 16" U -BLOCK OR BOND BEAM SHALL CONSIST OF TWO 8" KNOCK -OUT BLOCKS. BARS SPECIFIED TO BE EACH FACE SHALL BE HELD IN PLACE WITH SPACERS AND SHALL BE LOCATED 2 3/8" FROM EACH FACE TO THE CENTER OF THE BAR. MASONRY WORK SHALL BE INSPECTED IN ACCORDANCE WITH ACI 530 QUALITY ASSURANCE LEVEL 2. STEEL ALL STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING: ASTM A992 FOR W -SHAPES ASTM A36 FOR PLATES, ANGLES, & MISC FRAMING ASTM A588, GRADE 50, WHERE NOTED ASTM A501 OR A53 FOR PIPE ASTM A500, GRADE B FOR TUBES HEADED STUDS SHALL COMPLY WITH ASTM A108 AND SHALL, BE AUTOMATICALLY END WELDED PER MANUFACTURER'S RECOMMENDATIONS. ANCHOR RODS SHALL CONFORM TO ASTM F1554. GRADE 36, NO. ALL CONNECTION BOLTS SHALL CONFORM TO ASTM A325. WELDING OF STRUCTURAL STEEL SHALL BE PER AWS D1.1. LATEST EDITION. WHERE FILLET WELD SIZE ISN'T CALLED -OUT ON WELD SYMBOL, FILLET SIZE SHALL BE 1/16 SMALLER THAN THE THICKNESS OF THE THINNER OF THE ELEMENTS TO BE WELDED. STRUCTURAL STEEL SHALL BE SHOP PRIMED PER SSPC PAINT SYSTEM NO. 7.00. PRIMER SHALL BE SSPC PAINT WITH A MINIMUM DRY FILM THICKNESS OF 2.0 MILS. OMIT PAINT AT SURFACES TO BE FIREPROOFED. TOUCH-UP BOLT HEADS, NUTS, FIELD WELDS, AND ABRASIONS IN SHOP PRIMER WITH SAME PAINT. ALL STEEL EXPOSED TO WEATHER SHALL BE GALVANIZED. IF ANY DISCREPANCIES BETWEEN SPECIFICATIONS, NOTES, AND DRAWINGS ARE NOTED, THE MORE STRINGENT REQUIREMENT GOVERNS. COLUMN ANCHOR BOLTS ARE DESIGNED FOR COMPLETE CO DITION ONLY. CONTRACTOR SHALL PROVIDE ALL TEMPORARY BRACING REQUIRED TO MAINTAIN STABILITY UNTIL ALL BRACING ELEMENTS REQUIRED FOR STRUCTURAL STABILITY ARE IN PLACE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF MISC STEEL SHOWN ON THE STRUCTURAL DRAWINGS SUCH AS SHELF ANGLES, LINTELS, SUPPORT MEMBERS FOR CURTAIN WALL OR MASONRY AND EDGE ANGLES FOR OPENINGS AND PERIMETER CONDITIONS. IT IS THE INTENT OF THESE DRAWINGS THAT THESE ITEMS ARE FIELD ATTACHED BY FIELD WELDING OR FIELD BOLTING TO MEET TOLERANCES REQUIRED BY THE OTHER TRADES, THESE TOLERANCES MAY BE MORE STRINGENT THAN AISC TOLERANCES. THE CONTRACTOR SHALL COMPARE THE STRUCTURAL PLANS AND DETAILS WITH THE ARCHITECTURAL PLANS AND DETAILS AND REPORT ANY DISCREPANCIES TO THE ARCHITECT PRIOR TO THE COMMENCEMENT OF SHOP DRAWINGS. WOOD CLIPS, CONNECTIONS, HANGERS, HOLD-DOWNS, ETC. SHOWN PN THESE DRAWINGS ARE SIMPSON STRONG -TIE CONNECTORS, UNO. FASTENERS OF OTHER MANUFACTURERS MAY BE SUBSTITUTED PROVIDED THE LOAD VALUES OF THE SUBSTITUTED FASTENER FOR GROUP II WOOD SPECIES EQUALS OR EXCEEDS THE SPECIFIED FASTENER. NAILING OF ALL MEMBERS SHALL BE IN ACCORDANCE WITH THE BUILDING CODE. SEE CODE FOR TABLE. ALL SLEEPERS AND SILLS SHALL BE MADE OF PRESSURE TREATED WOOD. PROVIDE A MINIMUM OF 3 STUDS UNDER BEAMS OR GIRDER TRUSSES CARRYING FLOOR OR ROOF LOADS. HOLES AND NOTCHES MUST BE APPROVED BY THE ENGINEER. IF APPROVED THE NOTCHES ON THE ENDS OF JOISTS SHALL NOT EXCEED ONE-FOURTH THE DEPTH. HOLES BORED FOR PIPE OR CABLE SHALL NOT BE WITHIN THE TOP OR BOTTOM THIRD OF THE JOIST DEPTH AND THE DIAMETER OF SUCH HOLE SHALL NOT EXCEED ONE-THIRD THE JOIST DEPTH NOTCHES FOR PIPES IN THE TOP OR BOTTOM OF JOISTS SHALL NOT EXCEED ONE-SIXTH THE JOIST DEPTH AND SHALL NOT BE LOCATED IN THE MIDDLE ONE-THIRD OF THE SPAN. STRESS GRADE: SOUTHERN PINE NO. 2 OR ENGINEER APPROVED EQUAL. ALL DESIGN VALUES ARE UNDER NORMAL LOADING AND IN DRY CONDITIONS OF SERVICE. SYP MAY BE SUBSTITUTED FOR SPF. PRESSURE -TREAT LUMBER IN ACCORDANCE WITH THE MANUAL OF RECOMMENDED PRACTICE OF THE AMERICAN WOOD PRESERVERS ASSOCIATION (AWPA). ALL FASTENERS AND NAILS IN CONTACT WITH PRESSURE TREATED LUMBER SHALL BE MADE OF TYPE 304 OR TYPE 316 STAINLESS STEEL UNLESS THE LUMBER IS TREATED WITH CCA -C OR SBX (DOT), BUT NOT SBX (DOT) WITH SODIUM SILICATE (NaSi02). UNLESS OTHERWISE NOTED, USE THE FOLLOWING MINIMUM GRADE OF LUMBER FOR FRAMING. FRAMING MINIMUM GRADE SILL ON FOUNDATION WALLS OR NO. 3 SYP SLAB ON GRADE JOISTS, RAFTERS & HEADERS NO.2 SYP PLATES, CAPS & BUCKS NO.2 SYP STUDS SEE SCHEDULE POSTS & COLUMNS NO. 2 SYP CONNECT OVER FRAMING (SUCH AS VALLEY TRUSSES) TO M IN ROOF FRAMING BELOW WITH SIMPSON VTCR WITH 4-10d NAILS INTO TRUSS AND 3-10d x 1 U22" NAILS INTO OVERFRAMING OR I 1/4"x16 ga TWIST STRAP @ 48" MAX W/ 7-1Od NAILS EACH END OF STRAP. POST INSTALLED ANCHORS POST- INSTALLED ANCHORS SHALL ONLY BE USED WHERE SPECIFIED ON THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE EOR PRIOR TO INSTALLING POST- INSTALLED ANCHORS IN PLACE OF MISSING OR MISPLACED CAST -IN-PLACE ANCHORS. HOLES SHALL BE DRILLED AND CLEANED IN ACCORDANCE WITH THE MANUFACTURERS WRITTEN INSTRUCTIONS. SUBSTITUTION REQUESTS FOR PRODUCTS OTHER THAN THOSE SPECIFIED BELOW SHALL BE SUBMITTED BY THE CONTRACTOR TO THE EOR ALONG WITH CALCULATIONS THAT ARE PREPARED & SEALED BY A REGISTERED PROFESSIONAL ENGINEER. THE CALCULATIONS SHALL DEMONSTRATE THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF ACHIEVING THE PERTINENT EQUIVALENT PERFORMANCE VALUES (MINIMUM) OF THE SPECIFIED PRODUCT USING THE APPROPRIATE DESIGN PROCEDURE AND/OR STANDARD(S) AS REQUIRED BY THE BUILDING CODE. PROVIDE CONTINUOUS SPECIAL INSPECTION FOR ALL MECHANICAL AND ADHESIVE ANCHORS PER THE APPLICABLE EVALUATION REPORT. CONCRETE ANCHORS • MECHANICAL ANCHORS: SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ACI 355.2 AND ICC -ES AC 193 FOR CRACKED AND UNCRACKED CONCRETE RECOGNITION. PRE -APPROVED MECHANICAL ANCHORS INCLUDE: -SIMPSON STRONG TIE "TITEN-HD" SIMPSON STRONG TIE "TITEN" SIMPSON STRONG TIE "TORQ-CUT" -HILTI "KWIK BOLT 3" • ADHESIVE ANCHORS: SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ACI 355.4 AND ICC -ES AC308 FOR CRACKED AND UNCRACKED CONCRETE RECOGNITION. PRE -APPROVED ADHESIVE ANCHORS INCLUDE: -HILTI "HY 200-A" -SIMPSON "SET - XP" • POWDER AND GAS ACTUATED FASTENERS: SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ICC -ES AC70. PRE -APPROVED MECHANICAL ANCHORS INCLUDE: SIMPSON STRONG TIE "POWER DRIVEN FASTENERS" -SIMPSON STRONG TIE "GAS ACTUATED FASTENERS" MASONRY ANCHORS • MECHANICAL ANCHORS: SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ICC -ES ACO 1 OR AC 106. PRE -APPROVED MECHANICAL ANCHORS INCLUDE: -SIMPSON STRONG TIE "TITEN-HD" SIMPSON STRONG TIE "TITEN" BUILDEX "TAPCON" -HILTI "KWIK BOLT 3" • ADHESIVE ANCHORS: SHALL HAVE BEEN TESTED AND QUALIFIED FOR USE IN ACCORDANCE WITH ICC -ES AC58. PRE -APPROVED ADHESIVE ANCHORS INCLUDE: -HILTI "HY 70" SIMPSON "SET -XP" ANCHORS INSTALLED IN CONCRETE MASONRY SHALL BE INSTALLED INTO SOLID GROUTED CONCRETE MASONRY. ADHESIVE ANCHORS SHALL BE INSTALLED WITH 12 BAR DIAMETER EMBEDMENT MINIMUM UNO. SUPPLEMENTARY NOTES THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE DESIGN, ADEQUACY, AND SAFETY OF ERECTION, BRACING, SHORING, TEMPORARY SUPPORTS, ETC. THE STRUCTURAL ELEMENTS ARE NOT CONSIDERED STABLE UNTIL THE STRUCTURE IS COMPLETE. REVIEW OF THE SUBMITTAL INFORMATION SHALL BE FOR GENERAL REQUIREMENTS OF THE PROJECT, AND SHALL NOT INCLUDE CHECKING OF DETAILED DIMENSIONS OR DETAILED QUANTITIES, NOR REVIEW OF THE CONTRACTOR'S SAFETY MEASURES ON OF OFF THE WORKSITE OR THE MEANS AND METHODS OF DOING ANY WORK. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND ARCHITECTURAL AND STRUCTURAL PLAN DIMENSIONS AND ELEVATIONS PRIOR TO THE COMMENCEMENT OF CONSTRUCTION AND NOTIFY THE STRUCTURAL ENGINEER OF ANY CONFLICTS. ALL STRUCTURAL OPENINGS AROUND OR AFFECTED BY MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT SHALL BE VERIFIED WITH EQUIPMENT PURCHASED BEFORE PROCEEDING WITH STRUCTURAL WORK AFFECTED. ANY ENGINEERING DESIGN PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW SHALL BEAR THE SEAL OF AN ENGINEER REGISTERED IN THE STATE OF THE PROJECT. GENERAL CONTRACTOR MUST REVIEW AND APPROVE SHOP DRAWINGS PRIOR TO SUBMITTAL TO ARCHITECT/ENGINEER. SUBMITTALS WHICH DO NOT CONTAIN THE CONTRACTOR'S SHOP DRAWING STAMP OR HAVE BEEN MERELY "RUBBER STAMPED" SHALL BE RETURNED WITHOUT REVIEW. CONTRACTOR SHOULD ALLOW TWO WEEKS FOR SUBMITTAL REVIEW. CONTRACTOR SHALL NOT ORDER MATERIAL OR COMMENCE WITH CONSTRUCTION UNTIL SHOP DRAWINGS HAVE BEEN REVIEWED AND APPROVED. WORK DONE OR ORDERS PLACED BEFORE SHOP DRAWING APPROVAL IS AT THE CONTRACTOR'S RISK. THE PROJECT'S STRUCTURAL DRAWINGS AND ELECTRONIC FILES ARE THE PROPERTY OF LOWE STR CTURES, INC. THE CONTRACTOR AND SUBCONTRACTOR SHALL COMPENSATE LOWE STR JCTURES, INC. FOR THE USE OF THE PROJECT'S CAD FILES FOR ANY PURPOSE INCLUDING SHOP DRAWING PREPARATION. THE CONT CTOR SHALL NOT SCALE DRAWINGS. DIMENSIONS SHOWN ON ARCHITECTURAL AND STRUCTURAL PLANS AND DETAILS WILL CONTROL. Ir71 RTIT610 COMPONENT & CLADDING DESIGN WIND PRESSURES (PSF) ROOF "ZONE 10 SF 50 SF 100 SF ALL ZONES +30.0 +23.8 +21.2 1 -47.6 -44.6 -43.2 2 -82.9 -67.5 -60.9 3 -82.9 -67.5 -60.9 lo & 20 -97.1 -97.1 -97.1 3o -97.1 -97.1 -97.1 WALLS ZONE 10 SF 100 SF 500 SF 4 +52.1 +44.3 +38.8 -56.5 -48.7 -43.3 5 +52.I I +44.3 +38.8 - -- -69.7 ! ------- -54.1 -4.1 i _----_� NOTES: 1. TABLE PRESSURES ARE FOR THE SQUARE FOOT (SF) TRIBUTARY AREA SHOWN. FOR OTHER TRIBUTARY AREAS, LINEARLY INTERPOLATE BETWEEN VALUES SHOWN ABOVE. 2. POSITIVE PRESSURES ACT TOWARD THE BUILDING. NEGATIVE PRESSURES ACT AWAY FROM THE BUILDING. 3 SEE DIAGRAMS FOR ZONE LOCATIONS. 4. ALL PRESSURES SHOWN ARE ULTIMATE PRESSURES. a = 4'-0" ;y O � o (D I O O� "�- (D O1 ROOF PLAN (GENERIC BUILDING SHOWN) t -I I I-'-1 SCALE: NTS REVIEWED FOR CODE COMPLIANCE CITY OF ATLANTIC BEACH SEE PERMITS FOR ADDITIONAL REQUIREMENTS AND CONDITIONS �y REVIEWED BY: DATE: eI d DEP Permit Issue LOWE STRUCTURES INC. 11651 Central Pkwy. Suite 106 Jacksonville, FL 32224 (904)992-0377 FL Cert of Auth: 28261 EOR: J. Matthew Lowe FI, PE: 59027 z O LJ �- 0 ® ®N M <::) LLJ W CV M z J W 06 An -ow W > _ U z Uw C/) W Co F- z co L_ �z cy T J Q 0 0 d z 0 W No. 9027 ® STATE OF Q .• � P etc, a °°•• L OR\ ��.q� ••. REVISION PROGRESS PRINTING GENERAL NOTES & DESIGN CRITERIA DATE: 8/7/2018 PROJECT#: 18095 p 1 SECTION S2.17 SCALE: NTS DE (2)-THRU AT B EAM ENDS (TYP) T/EXIST SLAB EL h EXIST CMU WALL STL CHANNEL EA SIDE OF WALL PER PLAN W/ 5/8"0 THRU BOLTS 1/81 / 2@6 CONT 1/2" PL 2SECTION S2.1 SCALE: NTS EXIST FLOOR SHEATHING EXIST FLOOR TRUSS 5 DETAIL 6 SECTION S2.1 SCALE: NTS 52.1 SCALE: NTS WALL PROVIDE #6 EF OPENING @ OPENINGS 5'-4" AND LESS as El 11 1� ADD #6 EF @ TYP WALL OPENINGS > 5'-4" REINF REINF @ WALL OPENING < 8'-0" NOTE: ADD #5 HORZ UNDER ALL WINDOW OPENINGS. EXTEND REINF 16" BEYOND OPENING (TYP). WALL PROVIDE #6 EF IN OPENING 3 CELLS OPENINGS > 8'-0" ED In M-101 0 TYP WALL REINF REINF @ WALL OPENING > 8'-0" NOTES: 1. MAX LIFT = 5'-0" WITH LOW LIFT GROUT. 2. IF HIGH LIFT GROUTING IS USED, REINFORCING SHALL BE FULL HEIGHT & A CLEANOUT HOLE IS REQ'D @ CELLS W/ REBAR. GROUT SHALL BE PLACED IN LIFTS TO PREVENT BLOWOUTS. 3. LAP REINFORCING PER GENERAL NOTES. 4. JOINT REINF SHALL CONSIST OF @ LEAST TWO WIRES OF W 1.7 OR GREATER AND SHALL BE PLACED AT 16" OC VERTICALLY. SHALL BE PLACED AT 16" OC VERTICALLY. 5. PROVIDE A STANDARD HOOK AT EACH VERT BARS AT THE TOP OF WALL. 6. PROVIDE A MINIMUM OF AN 8" CONTINUOUS BOND BEAM AT THE TOP OF EACH WALL W/ #5 CONTINOUS BOTT, UNO IN DETAILS. TYP CMU REINF DETAILS SCALE: NTS SEALANT EA FACE PER ARCH GASKET FULL WALL .HEIGHT ]oo a #6 EA SIDE OF CONTROL JOINT NOTES: 1. COORD REQD CMU CONTROL JOINTS W/ ARCH. 1. STOP CMU JOINT RINF EA SIDE OF JOINT (TYP). REINF @ CONTROL JOINT PLAN DETAIL GROUT CELLS SOLID @ THRU- BOLT LOCATIONS T/OPNG EL gl--, PER ARCH 2X BLOCKING BETWEEN TRUSSES W/ l Od NAILS @ 6" OC STAGGERED EXIST WD BEAM EXIST FLOOR SHEATHING TRUSS BRG EL PER PLAN EXIST CMU WALL T/EXIST WALL LL NOTE: INSTALL STEEL CHANNELS BEFORE REMOVING CMU SECTIONS. CONTRACTOR SHALL CUT AND REMOVE CMU AS REQD FOR NEW OPENINGS AFTER NEW STEEL MEMBERS HAVE BEEN PROPERLY INSTALLED. SIMPSON H2.5A @ EA FLOOR JOIST CONT DBL 2x TOP PL W/ CONT 16" BOND 5/8" 0 EPDXYANCHORS BEAM W/ (1)-#5 @ 24" OC W/ 8" MIN T/EXIST SLAB EL OL CONT TOP & BOTT Misr EMBED WALL REINF CMU WALL PER GENERAL NOTES 2' - 0" 14'-8" MAX 2'- 0" PER PLAN GROUT CELLS SOLID EA SIDE Ol' ()i -' "NI CI 3 SECTION 4 TYP OPENING DETAIL S2.1 SCALE: NTS \1145f 2.1 SCALE: NTS TRUSS BRG EL OL PER PLAN CMU REINF CAS'r CRETE 8F8 -1T/ PRECAST LINTEL Gn EOR APPROVED EQUAL 0 CMU REINF ---- N CAST CRETE 8F24-IT/1B T�TnUr n 0r T T7.rrrE7T nn FOR APPROVED EQUAL MAX OPENING = 4'-0" MAX OPENING = 10'-0" SIMPSON H2.5A @ EA TRUSS NOTES: 1. FOR OPNG LOCATIONS SEE ARCH DWGS. 2. PROVIDE 8" BEARING EACH SIDE OF OPENING. WD BEAM PERPLAN7 TYP CMU LINTEL DETAILS 52.1 SCALE: NTS WALL SHEATHING BUILT-UP STUDS PER ARCH PER PLAN SIMPSON HTT4 EXIST SLAB & GRADE BEAM 10 SECTION S2.1 SCALE: NTS PL 3/4„ ) EPDXY 1 1/2" 8 DETAIL 52.1 SCALE: NTS CHANNEL PER PLAN DEP Permit Issue !L LOWE STRUCTURES INC. 1 1651 Central Pkwy. Suite 106 Jacksonville, FL 32224 (904) 992-0377 FL Cert of Auth: 28261 EOR: J. Matthew Lcwe FL PE: 59027 w z Z O W Q ® ® M ® N W N —) M W LULL ,� x W W W > 2 Cr. TL Q U z w ®w m� �' z Q"'¢ \ r LL / ® Q 0 (D z 0 LU Cr C.) en sk!!inf!e� J3rngr�� 59027 STATE OF CN, q.; b.03 j'aq REVISION PROGRESS PRINTING SECTIONS & DETAILS DATE: 8/7/2018 PROJECT#: 18095 S2ml