1607 ATLANTIC BCH IN-PLACE DENS TEST UN ' V E K S A L UES Project No: 0910.1400187.0000 Workorder No: 214094-1 ENGINEERING SCIENCES Report Date: 2/8/2019 Consultants In:Geotechnical Engineering-Environmental Sciences Geophysical Services-Construction Materials Testing-Threshold Inspection EB Building Inspection-Plan Review-Building Code Administration 5561 Florida Mining Blvd So.,Jacksonville, 32257 - P: 904-296-0757 - F: 904-29"748 In-Place Density Test Report Client: Toll Brothers, Inc 160 Cape May Avenue UES Technician: Kevin Gagnon Ponte Vedra, FL 32081 Date Tested: 02/08/2019 Project: Atlantic Beach Country Club Atlantic Beach Country Club , Atlantic Beach, Duval County, FL Area Tested: lot 2 Twe of Test: Material: Fill Field: ASTM D-6938 Nuclear Gauge Metho Reference Datum: 0 = Top of Fill Laboratory: ASTM D1557 Modified Proctor The tests below meet the minimum 95% relative soil compaction requirement of Laboratory Proctor maximum dry density. aximum ptimum Field Dry Field Soil Fill Test Density Moisture Density Moisture Compaction Depth Pass No. Location of Test Range (pcf) (%) (pcf) (W 1%t (inch) or Fail 1 25' S 25' E of NW corner 0-1 ft 98.4 16.1 94.0 9.8 96 N/A Pas: 2 20' N 15'W of SE corner 0-1 ft 98.4 16.1 93.4 9.9 95 N/A Pas: 3 15' N 20' E of SW corner 0-1 ft 98.4 16.1 95.1 7.7 97 N/A Pas: 4 20' S 20'W of NE corner 0-1 ft 98.4 16.1 93.7 8.2 95 N/A Pas: o - o37Z To establish a mutual protection to Universal's clients,the Public and ourselves, all reports are submitted as confidential property of our clients and authorization