1607 ATLANTIC BCH IN-PLACE DENS TEST UN ' V E K S A L UES Project No: 0910.1400187.0000
Workorder No: 214094-1
ENGINEERING SCIENCES Report Date: 2/8/2019
Consultants In:Geotechnical Engineering-Environmental Sciences
Geophysical Services-Construction Materials Testing-Threshold Inspection
EB Building Inspection-Plan Review-Building Code Administration
5561 Florida Mining Blvd So.,Jacksonville, 32257 - P: 904-296-0757 - F: 904-29"748
In-Place Density Test Report
Client: Toll Brothers, Inc
160 Cape May Avenue UES Technician: Kevin Gagnon
Ponte Vedra, FL 32081 Date Tested: 02/08/2019
Project: Atlantic Beach Country Club
Atlantic Beach Country Club , Atlantic Beach, Duval County, FL
Area Tested: lot 2 Twe of Test:
Material: Fill Field: ASTM D-6938 Nuclear Gauge Metho
Reference Datum: 0 = Top of Fill Laboratory: ASTM D1557 Modified Proctor
The tests below meet the minimum 95% relative soil compaction requirement of Laboratory Proctor maximum dry density.
aximum ptimum Field Dry Field Soil Fill
Test Density Moisture Density Moisture Compaction Depth Pass
No. Location of Test Range (pcf) (%) (pcf) (W 1%t (inch) or Fail
1 25' S 25' E of NW corner 0-1 ft 98.4 16.1 94.0 9.8 96 N/A Pas:
2 20' N 15'W of SE corner 0-1 ft 98.4 16.1 93.4 9.9 95 N/A Pas:
3 15' N 20' E of SW corner 0-1 ft 98.4 16.1 95.1 7.7 97 N/A Pas:
4 20' S 20'W of NE corner 0-1 ft 98.4 16.1 93.7 8.2 95 N/A Pas:
o - o37Z
To establish a mutual protection to Universal's clients,the Public and ourselves, all reports are submitted as confidential property of our clients and authorization