1605 Linkside Dr. POOL18-0046 dwgs 1Simplified Total Dynamic Head Calculation 2.34 Distance from nearest edge of pool to pump in feet = 25 Pool Only 2.5"@ Determine Maximum System flow Rate: Friction loss in return pipe 2rr @ 10 fps inch pipe per one foot @ Swimming Pool Info: 180 3 to 5 to N,/A Volume: 4300 gallons ( Surface Area (Shallow) (Deep) (Shallow) 13.6 Spa Info: N/A 0 0 20.3 Volume: 0 gallons ( Surface Area (Depth) 4.6 6.8 3.1 11.4 13.6 4300 Total Volume Preferred Turnover Time in Hours : 6 x 60 min. _ _360 (Hours) (turnover tin ie in minutes) 3.1 Maxium Pool Flow Rate: 4300 divided by 360 12 gpm 0 = 12 gpm (gallons) (turnover time in minutes) (flow rate pool) (feature flow rate) Spa Jets (#) 4 x 13 gpm per jet = 52 flow rate (# of jets) (jet flow) 16.0 18.2 A&A Quik Clean System NONE x 0 gpm Cleaner Head 0 flow rate NONE x 0 gpm Cleaner Head 0 flow rate NONE x 0 gpm Cleaner Head 0 flow rate (# of heads) (head flow) 0 Total Floor Heads flow rate Maximum Pool System Flow Rate: 52 4- Highest required flow rate between "Maximum Pool Flow 1 13.8 16.1 Rate" and "Spa Jets" and "Quick Clean System" Determine Pipe Sizes: 25.1 27.4 23.6 Pool/Spa: Branch piping to be: 3" inch to keep velocity @ 6 fps.Max.at : 136 gpm. Maximum System Flow Rate Trunk piping to be : 2.5rr inch to keep velocity @ 8 fps.Max.at : 117 gpm. Maximum System Flow Rate Return piping to be 2rr inch to keep velocity @ 10 fps.Max.at : 103 gpm. Maximum System Flow Rate Determine Simplfied TDH (POOL): 2.34 Distance from nearest edge of pool to pump in feet = 25 Friction loss in suction pipe 2.5"@ 8 fps inch pipe per one foot @ Friction loss in return pipe 2rr @ 10 fps inch pipe per one foot @ Length of suction pipe 25 x Ft. of head per one foot of pipe Length of pressure pipe 25 x Ft. of head per one foot of pipe Other Loss in TDH Main Drain Returns 3/4" Therapy Jet Floor System *Total 117 gpm ( from pipe flow/friction loss chart) = 0.09 103 gpm ( from pipe flow/friction loss chart) = 0.16 0.09 = 2.25 TDH in piping 0.16 = 4.00 TDH in piping 1 un m pipuig Filter loss in TDH (from filter data sheet) Heater loss in TDH (`rom heater data sheet) *Total all other loss Pool Total Dynarnk Head (TDH) Pool Pump: Jandy FloPro VS -FHP 1 hp 52 Gallons Per Minute 14 Total Dynamic Head (TDH) Pool Filter: Jandy CS100 Cartridge Heater: JXi260P Jandy Pro Series (LF' as Pool Nova 7-314rr Pool Drain Main Drain: F?7ft0in._?] Floor Installation @ 150 gpm max. flow W.LJ 1.70 ( from filter data sheet) 0.00 (from heater data sheet) 9 RA I -r r ft. of head # 2.34 2.34 1 3.30 3.30 1 0.00 27.72 0 0.00 19.65 0 5.64 0.0 117 gpm ( from pipe flow/friction loss chart) = 0.09 103 gpm ( from pipe flow/friction loss chart) = 0.16 0.09 = 2.25 TDH in piping 0.16 = 4.00 TDH in piping 1 un m pipuig Filter loss in TDH (from filter data sheet) Heater loss in TDH (`rom heater data sheet) *Total all other loss Pool Total Dynarnk Head (TDH) Pool Pump: Jandy FloPro VS -FHP 1 hp 52 Gallons Per Minute 14 Total Dynamic Head (TDH) Pool Filter: Jandy CS100 Cartridge Heater: JXi260P Jandy Pro Series (LF' as Pool Nova 7-314rr Pool Drain Main Drain: F?7ft0in._?] Floor Installation @ 150 gpm max. flow W.LJ 1.70 ( from filter data sheet) 0.00 (from heater data sheet) 9 RA I -r r Total Head in Feet Conversion Chart _.. _ Inches Mercury (Vacuum Gauge) 2_.. 4 6 _.$ 10 12 _14 ....16. 18 ,, 4_ 0.0 2.3 4.5 6.8 3.0 11.3 13.6 15.8 18.1 1 20.3 1 2.3 4.6 6.8 3.1 11.4 13.6 15.3 18.1 20.4 22.7 4.6 6.3 3.1 11.4 13.7 15.8 18.2 20.4 22.7 25.0 ^3 6.3 8.2 11.5 13.7 16.0 18.2 20.5 22.8 25.0 27.3 4 3.2 11.5 13.8 16.0 18.3 20.5 22.8 25.1 27.3 28.6 `S 11.6 1 13.8 16.1 18.3 20.6 22.3 25.1 27.4 23.6 31.3 6 13.3 16.1 18.4 1 20.6 22.3 25.2 27.4 1 28.7 31.3 34.2 `7 16.2 18.4 20.7 23.0 25.2 27.5 23.7 32.0 34.3 36.5 I! 8 18.5 20.7 23.0 25.3 27.5 23.8 32.0 34.3 36.6 38.8 9 20.8 23.1 25.3 27.6 23.8 32.1 34.4 36.6 1 38.3 41.1 !'. 10 23.1 25.4 27.6 23.3 32.1 34.4 36.7 38.3 41.2 43.4 11 25.4 27.7 23.3 32.2 34.5 36.7 33.0 41.2 43.5 45.8 12 27.7 1 30.0 32.2 34.5 1 36.8 33.0 1 41.3 43.5 45.8 48.1 L'Si i 3 30.0 32.3 34.6 36.8 33.1 41.3 43.6 45.3 48.1 50.4 14 32.3 34.6 36.3 1 33.1 41.4 43.6 45.3 48.2 50.4 52.7 15 34.7 36.3 38.2 41.4 43.7 46.0 48.2 50.5 52.7 55.0 "16 37.0 33.2 41.5 43.7 46.0 48.3 50.5 52.8 55.0 1 57.3 -17 33.3 41.5 43.8 46.1 48.3 50.6 52.8 55.1 57.4 53.6 Vt 18 41.6 43.8 46.1 48.4 50.6 52.3 55.1 57.4 53.7 61.3 +IM 19 43.3 1 46.2 48.4 50.7 52.3 55.2 57.5 53.7 62.0 64.2 i_20 46.2 48.5 50.7 53.0 55.2 57.5 53.8 62.0 64.3 66.5 it ,+ 21 48.5 50.8 53.0 55.3 57.6 53.8 62.1 64.3 66.6 68.3 j 22 50.8 53.1 55.3 57.6 53.3 62.1 64.4 66.6 68.3 71.2 23 53.1 55.4 57.7 53.3 62.2 64.4 66.7 63.0 71.2 1 73.5 24 55.4 57.7 60.0 62.2 64.5 66.7 1 63.0 71.3 73.5 75.8 25 57.8 60.0 62.3 64.5 66.8 63.1 71.3 73.6 75.8 78.1 26 60.1 62.3 64.6 66.8 63.1 71.4 73.6 75.3 78.1 80.4 27 62.4 64.6 66.3 63.2 71.4 73.7 75.3 78.2 80.5 82.7 28 64.7 66.3 63.2 71.5 73.7 76.0 78.2 80.5 82.8 85.0 29 67.0 63.3 71.5 73.8 76.0 78.3 80.6 $2.8 85.1 87.3 3d 68.3 71.6 73.8 76.1 78.3 80.6 82.8 1 85.1 87.4 1 83.6 ',. X31 71.6 73.3 76.1 78.4 80.7 82.3 85.2 87.4 83.7 32.0 32 73.3 76.2 78.4 80.7 83.0 85.2 87.5 83.7 32.0 34.3 '.. '.'.... .33 76.2 78.5 80.8 83.0 85.3 87.5 83.8 82.1 34.3 36.6 ;. 34 785 80.8 83.1 85.3 87.6 83.8 32.1 34.4 36.6 38.3 '... 35 80.8 83.1 85.4 87.6 83.3 32.2 34.4 86.7 38.3 101.2 Design Head' Loss (f head) 0 30 60 90 120 Flow Rate (gpml Design Pressure 2 WOW (P$i) *• CS150 1 CS200 - - CS250 i CS100 0 4P Pools • Spas • Service Tracy & Carla Gerow 1605 Linkside Drive Atlantic Beach 32233 11 12/20/2018 -� 3' 0" MINIMUM 3" TEE I "PIP�E_ �PIPEED. BUSHING ' -2';2" TRUNK TO EQ. LEGEND N N r � N N N N r r 3WAY JVA AQUA PURE 700 FLOW SWITCH PUMP HEATER O (FILTER POOL W/ PROPANE HEATER FILTER SCHEMATIC PERMIT PLAN POOL 15'-6" X 15'-0" W/ STUB OUT FOR FUTURE CLEANER AND 3 WALL RETURNS 12" SEGMENTED RETAINING WAI NEW DECK TO RECEIVE STANDARD PAVERS NAPOLI, MEGA CAMBRIDGE 4 EXISTING DECK NOT TO RECEIVE FINISH --_/ STUB OUT FOR PREPLUMB i CLEANER RETURN 12" BELOW BEAM 1 � '6• LE V BEL m� Zn s 1 DECO DRAIN 45 LN Fj INSULATED #8 BOND WIRE IN CONDUIT FROM LIGHT NICHES THROUGH DECK BOX. LIGHT GFCI PROTECTED. AN UNDERGROUND BONDING CONDUCTOR MADE OF A SINGLE #8 AWG BARE SOLID COPPER WIRE BURIED TO A MINIMUM DEPTH OF 4 INCHES TO 6 INCHES BELOW SUB GRADE, AND 18 INCHES TO 24 INCHES FROM INSIDE THE WALL OF A SWIMMING POOL OR SPA WILL BE USED. Florida Building Code 6`-'' Edition (2017) Residential Conforms to Chapter 42 l]l 2014 National Electrical Code • NO OVERHEAD ELECTRIC IN POOL AREA • NO UNDERGROUND UTILITIES IN POOL AREA • FINISH GRADE TO SLOPE A1,",'AY FROM POOL • VGB COMPLIANT MAIN DRAIN DRAINAGE DETAIL— FINISH GRADE SLOPE A''<i1/AY FROM POOL. • GROUNDING & BONDING DETAIL = JANDY WHITE LED LIGHT [D = WALL RETURN I = SKIMMER = STUB OUT FOR CLEANER WIAUTOFILL = THERAPY JET J OO =NOVA DRAIN N N r � N N N N r r 3WAY JVA AQUA PURE 700 FLOW SWITCH PUMP HEATER O (FILTER POOL W/ PROPANE HEATER FILTER SCHEMATIC PERMIT PLAN POOL 15'-6" X 15'-0" W/ STUB OUT FOR FUTURE CLEANER AND 3 WALL RETURNS 12" SEGMENTED RETAINING WAI NEW DECK TO RECEIVE STANDARD PAVERS NAPOLI, MEGA CAMBRIDGE 4 EXISTING DECK NOT TO RECEIVE FINISH --_/ STUB OUT FOR PREPLUMB i CLEANER RETURN 12" BELOW BEAM 1 � '6• LE V BEL m� Zn s 1 DECO DRAIN 45 LN Fj INSULATED #8 BOND WIRE IN CONDUIT FROM LIGHT NICHES THROUGH DECK BOX. LIGHT GFCI PROTECTED. AN UNDERGROUND BONDING CONDUCTOR MADE OF A SINGLE #8 AWG BARE SOLID COPPER WIRE BURIED TO A MINIMUM DEPTH OF 4 INCHES TO 6 INCHES BELOW SUB GRADE, AND 18 INCHES TO 24 INCHES FROM INSIDE THE WALL OF A SWIMMING POOL OR SPA WILL BE USED. Florida Building Code 6`-'' Edition (2017) Residential Conforms to Chapter 42 l]l 2014 National Electrical Code • NO OVERHEAD ELECTRIC IN POOL AREA • NO UNDERGROUND UTILITIES IN POOL AREA • FINISH GRADE TO SLOPE A1,",'AY FROM POOL • VGB COMPLIANT MAIN DRAIN DRAINAGE DETAIL— FINISH GRADE SLOPE A''<i1/AY FROM POOL. • GROUNDING & BONDING DETAIL PLUMBING LINE FROM POOL MAIN DRAINS TO POOL EQUIPMENT SAFETY BARRIERS: FENCE AND WATER ALARMS UP TO POOL SAFETY CODE. co GRAVITY I OVERFLOW LIGHT I I WIAUTOFILL BEAM �1 I DEEP I ' Y I 1 ' ' I I � N I 1 I i N O p W YZ) LO o 1 W W p D d Y Z � m W p V3 : d' PLUMBING LINE FROM POOL ' I I SKIMMER TO POOL EQUIPMENT a Z O O C/) W D_ Q LU J I DECK PDX: N I 1 - - - - I TRANSFORMER I BARE #8 BOND WIRE ATTACHED - 1 TO POOL STEEL 1 U.1 LU ° POOL EQUIPMENT PLUMBING LINE FROM POOL MAIN DRAINS TO POOL EQUIPMENT SAFETY BARRIERS: FENCE AND WATER ALARMS UP TO POOL SAFETY CODE. co co N 06 Y 2 C) �O J W N O p W YZ) LO o N W W p D d Y Z � m W p V3 : d' Z O LU W It 0 m to (J) p a Z O O C/) W D_ Q LU J M N w U.1 LU ,,nn V CO ryM W P I = 11 C W W U = 00 w w w Q W t- (L o p Y LU z I- W LU LLI Z �r w � U Q o m z w zC'� z W z W Lu F- z a z a d < Q U Q O M (Y W:) (n a U 0 a 0 cn co co N O co w J W U_ a J O W C� ti 06Z M (� 00 p W YZ) LO o U Q W m U Z Q W W p D d Y Z � m W p V3 : d' Z O LU W It 0 m to (J) p O O C/) W D_ Q LU J 0 Q (!) N JOB SPECIFIC PIPE SIZING, TOTAL DYNAMIC HEAD CALCULATIONS AND EQUIPMENT SPECIFICATIONS AND DOCUMENTATION ARE TO BE PROVIDED BY TNF POOL CONTRACTOR FOR EACH PROJECT. T! -IE POOL CONTRACTOR -MUST USE TNF MAXIMUM PLOW CAPACITY OF THE SELECTED PUMP AND PROVIDE HYDRAULIC CALCULATIONS FOR TDN TO DETERMINE PROPER PUMP AND PIPING SIZING. THE MANUFACTURER'S EQUIPMENT SPECIFICATIONS AND OTHER DOCUMENTATION FOR PUMPS, FILTERS, NEATER EQUIPMENT AND MAIN DRAINS AND COVERS ARE TO BE SUBMITTED FOR REVIEW AND DOCUMENTATION FOR SIZING TPE CIRCULATION SYSTEM, RECIRCULATION CHLORINATC POOL FILTER RETURN THE MAIN DRAIN PIPE INVERT NEEDS TO BE 1.5 TIMES THE DIAMETER DOWN FROM THE TOP OF THE MAIN DRAIN GRATE TO THE TOP OF THE MAIN DRAIN PIPE, IF THE PIF' -E COMES IN VERTICAL TO THE MAIN DRAIN BOX. IF THE MAIN DRAIN PIPE COMES INTO THE MAIN DRAIN BOX HORIZONTALLY, THE COVER FROM THE TOP OF THE GRATE TO THE TOP OF THE MAIN DRAIN PIPE NEEDS TO BE 1:5 TIMES THE DIA. OF THE MAIN DRAIN PIPE. 2-a3 BARS - 1 -1/2 TIMES THE DIA, I -I/2 TIMES THE DIA. CONT. IN _ 8"X8" BOND BEAM MAIN MAIN DRAIN DRAIN RETURN LINE (OPTION WALL RETURNS) ii II Ij `RETURN INLET (OPTION WALL RETURNS) RETURN INLET UNDERWATER LIGHT (OPTION WALL RE - -_-��MAIN UCTION 1 i I 11 1 I Ili III lil l i DRAINS MEET THE VIRGINIA GRAEME BAKER POOL AND SPA SAFETY ACT. III _ _ II-----------------r-----__---- I€ llJ II II � I I ii > / Z i RETURN INLET FLOOR RETURN 5 REOID, LOW PROFILE JUNCTION BOX UL APPROVED UNDERWATER LIGHT POOL SHELL 3000 Psi PUMP MIX CONCRETE PNEUMATICALLY APPLIED. V'-1" IN VERTICAL WALLS (TYP) G'-8" IN COVES AND FLOORS (TYP) 2500 MIN. GUNITE MAY BE SU65ITIUTED FOR 3000 PSI CONCRETE RETURN INLET /-SKIMMER /(O I i I I J I°I jl X74'=-------------.--__= IJ II. ------ __----- -____J RETURN LINE (OPTION WALL RETURNS) WATER LINE DECK OVER I a I POUR OR --I }-- rE3FAM COPING R CONT. 6" OF WATERICK BOND LINE TILES IINLET WALL RETURNS) TYPICAL SHIMMING FOOL ><3 BARS GRADE 40,12" O.C. 6.1X611 ERA VERTICAL AND CERAMIC TILE HORIZONTAL (TYP) WATER LINE 1/2" QUARTZ FINISH 1 b�� bW/ '` o - MAIN DRAIN RELIEF PLUG. OR 2" 0000%p>a°n HYDROSTATIC RELIEF VALVE, IF REQ'D. 0 ob o p0 O DEEP END FLOOR AND ROCKBED WALL REINFORCEMENT TO SLOPE BREAK - #3 BAR a 12" ON CENTER, EACH WAY t 8.0' DEEP #3 BAR a G' ON CENTER, EACH WAY > 8.0' DEEP AND OVER. k-411'"ING POOL SECTION 03 BARS 12" ON CENTER EACH WAY (GRADE 40) ALTERNATE BEAM FINISH DETAIL PAVER DECKING OR 4" THICK CONCRETE DECK W/ FIBER MIX 2500 PSI OR WIRE MESH GENERAL NOTES: L POOLI5 TO BE BUILT TO GOMPLY WITH FLORIDA, COUNTY AND CITY BUILDING CODES. 2. ALL METAL PARTS WITHIN 5 FT. WILL BE GROUNDED AS PER NATIONAL ELECTRIC CODE AND AS REQUIRED BY LOCAL INSPECTOR, 3. FILTRATION SYSTEM WILL HAVE SUFFICIENT CAPACITY TO PROVIDE A COMPLETE TURNOVER OF POOL WATER IN (12) TWELVE HOURS OR LESS. 4. POOL CONSTRUCTION TO BE THE SAME REGARDLESS OF 51ZE AND SHAPE. IF FILL 15 REQUIRED FOR 2 FT. TO 4 FT. OF WALL HEIGHT THEN WALLS HAVE TO BE REINFORCED WITH ADDITIONAL STEEL (8" O.C. BOTH WAYS) AND/ OR EXTRA HALL THICKNESS (8" TO 10') 5. ALL PVC PIPE WILL BE SCHEDULE 40. G. ALL METAL FIXTURES AND POOL LIGHTS 70 BE BONDED TO POOL STEEL AND GROUND WIRE. 1. POOL ALARMS DO NOT NEED TO BE HARDWIRED 8. 501L CONDITIONS AT POOL LOCATION ARE ASSUMED TO BE ADEQUATE FOR A SINGLE FAMILY DWELLING. 9. TERMITE CONTROL WILL BE APPLIED UNDER ALL POOL DECKS. IO. ALL PUMPS AND FILTERS WILL BE ANCHORED TO A CONCRETE PAD WITH TAP CON ANCHORS. 11. ALL POOL AND SPA SUCTION INLETS SHALL BR PROVIDED WITH A COVER THAT HAS BEEN TESTED AND ACCEPTED BY A RECOGNIZED TESTING FACILITY AND COMPLY WITH A.N.S.IJA.SME. A112.19; SM, "SUCTION FITTINGS FOR USE IN SWIMMING POOLS, 5PA5, HOT 7UB5, AND WHIRLPOOLS BATHTUB ADPL I ANGES" 12. THE POOL DESIGN WILL MEET CHAPTERS 42 AND 45 OF THE 2011 FLORIDA BUILDING CODE 6TH EDITION. 13. RESIDENTIAL POOLS MUST COMPLY WITH CHAPTERS 42 AND 45 OF THE 2011 FLORIDA BUILDING CODE GTH EDITION, 14. POOL CONSTRUCTION WILL MEET 2014 NATIONAL ELECTRIC CODE, SEE 68026 (5)(2)(b) FOR PERIMETER BONDING USING AT LEAST ONE(I) $18 AWG BARE SOLID COPPER CONDUCTOR. 15, FOR RESIDENTIAL POOLS UP TO A WATER DEPTH OF 8'-0" 1*3 REBAR 12" O.C.B.W. OVER 8'-O"; SPECIAL ENGINEERING 15 REQUIRED AND 15 NOT A PART OF THIS DRAWING SPECIFICATIONS. WALL THICKNESS SHALL PROVIDE CODE COVER OVER REINFORCING. FOR OVER 8'-0" A SPECIAL DESIGN WILL BE REQUIRED. 16. RESIDENTIAL POOLS SHALL COMPLY WITH THE ANSI/APSP/ICG-5 2011 FOR RESIDENTIAL INGROUND POOLS, ANS VAPEP/ICO-5 2014 FOR PERMANENTLY INSTALLED RESIDENTIAL SPAS, AND AN5I/AP5P/ICC-1 2013 FOR SUCTION ENTRAPMENT AVOIDANCE STANDARDS. AND ANSVAPSFACC-15A 2013 STANDARD FOR RESIDENTIAL SWIMMING POOL AND SPA ENERGY EFFICIENCY 11. DO NOT USE OR OPERATE POOL OR SPA IF THE SUCTION FITTING 15 MISSING, BROKEN, OR L005E. 18. IF THE SUCTION INLET SYSTEM, SUCH AS AN AUTOMATIC CLEANING SYSTEM, IS A VACUUM GLEANER SYSTEM WHICH HAS A SINGLE SUCTION INLET, OR MULTIPLE SUCTIONS INLETS WHICH CAN BE ISOLATED BY VALVES, THEN EACH SUCTION INLET SHALL PROTECT AGAINST USER ENTRAPt`i-ENT BY EITHER AN APPROVED ANTI -VORTEX COV -ER, 12" X 12" GRATE OR LARGER, OR OTHER APPROVED MEANS. COMPACTED SOIL UNDER FAR<ER i" iYNCNENSERG 4 ASSOC. INC CONCRETE DECK 11 PROFESSIONAL ENGINEERS LANDSCAPE ARCHITECTS 112q RIDGEWOOD AVENUE HOLLY HILL FLORIDA 32111 (386) 6-17-6881 FAX (386) 6*71-2114 NOT VALID WITHOUT EMBOSSED SEAL. - s ,��� '�- G FEB PARKER 1-1 PEN15EROP,E: X32645 TYFICAL RESIDENTAL SN/POOL DESIGN FOP, SURF51 DE POOLS 313 BEACH BOULEVARD JACKSONVILLE BEACH, FL. 32250 (904) 246-2666 STATE LICENSE OF0044080 THIS SIGNED AND SEALED SHEET IS TO BE USED AS A MASTER FILE COPY . IT WILL BE USED FOR A MAXIMUM PERIOD OF ONE YEAR EXPIRING ON 12/31/18. IF THE FLORIDA BUILDING CODE IS ALTERED OR MODIFIED BEFORE THAT DATE, THIS DRAWING MAY BE RENDERED VOID. SHEET I OF 5 / Z i RETURN INLET N5) -ill Z Il wII I W II itL j r ---- _-jL_� IINLET WALL RETURNS) TYPICAL SHIMMING FOOL ><3 BARS GRADE 40,12" O.C. 6.1X611 ERA VERTICAL AND CERAMIC TILE HORIZONTAL (TYP) WATER LINE 1/2" QUARTZ FINISH 1 b�� bW/ '` o - MAIN DRAIN RELIEF PLUG. OR 2" 0000%p>a°n HYDROSTATIC RELIEF VALVE, IF REQ'D. 0 ob o p0 O DEEP END FLOOR AND ROCKBED WALL REINFORCEMENT TO SLOPE BREAK - #3 BAR a 12" ON CENTER, EACH WAY t 8.0' DEEP #3 BAR a G' ON CENTER, EACH WAY > 8.0' DEEP AND OVER. k-411'"ING POOL SECTION 03 BARS 12" ON CENTER EACH WAY (GRADE 40) ALTERNATE BEAM FINISH DETAIL PAVER DECKING OR 4" THICK CONCRETE DECK W/ FIBER MIX 2500 PSI OR WIRE MESH GENERAL NOTES: L POOLI5 TO BE BUILT TO GOMPLY WITH FLORIDA, COUNTY AND CITY BUILDING CODES. 2. ALL METAL PARTS WITHIN 5 FT. WILL BE GROUNDED AS PER NATIONAL ELECTRIC CODE AND AS REQUIRED BY LOCAL INSPECTOR, 3. FILTRATION SYSTEM WILL HAVE SUFFICIENT CAPACITY TO PROVIDE A COMPLETE TURNOVER OF POOL WATER IN (12) TWELVE HOURS OR LESS. 4. POOL CONSTRUCTION TO BE THE SAME REGARDLESS OF 51ZE AND SHAPE. IF FILL 15 REQUIRED FOR 2 FT. TO 4 FT. OF WALL HEIGHT THEN WALLS HAVE TO BE REINFORCED WITH ADDITIONAL STEEL (8" O.C. BOTH WAYS) AND/ OR EXTRA HALL THICKNESS (8" TO 10') 5. ALL PVC PIPE WILL BE SCHEDULE 40. G. ALL METAL FIXTURES AND POOL LIGHTS 70 BE BONDED TO POOL STEEL AND GROUND WIRE. 1. POOL ALARMS DO NOT NEED TO BE HARDWIRED 8. 501L CONDITIONS AT POOL LOCATION ARE ASSUMED TO BE ADEQUATE FOR A SINGLE FAMILY DWELLING. 9. TERMITE CONTROL WILL BE APPLIED UNDER ALL POOL DECKS. IO. ALL PUMPS AND FILTERS WILL BE ANCHORED TO A CONCRETE PAD WITH TAP CON ANCHORS. 11. ALL POOL AND SPA SUCTION INLETS SHALL BR PROVIDED WITH A COVER THAT HAS BEEN TESTED AND ACCEPTED BY A RECOGNIZED TESTING FACILITY AND COMPLY WITH A.N.S.IJA.SME. A112.19; SM, "SUCTION FITTINGS FOR USE IN SWIMMING POOLS, 5PA5, HOT 7UB5, AND WHIRLPOOLS BATHTUB ADPL I ANGES" 12. THE POOL DESIGN WILL MEET CHAPTERS 42 AND 45 OF THE 2011 FLORIDA BUILDING CODE 6TH EDITION. 13. RESIDENTIAL POOLS MUST COMPLY WITH CHAPTERS 42 AND 45 OF THE 2011 FLORIDA BUILDING CODE GTH EDITION, 14. POOL CONSTRUCTION WILL MEET 2014 NATIONAL ELECTRIC CODE, SEE 68026 (5)(2)(b) FOR PERIMETER BONDING USING AT LEAST ONE(I) $18 AWG BARE SOLID COPPER CONDUCTOR. 15, FOR RESIDENTIAL POOLS UP TO A WATER DEPTH OF 8'-0" 1*3 REBAR 12" O.C.B.W. OVER 8'-O"; SPECIAL ENGINEERING 15 REQUIRED AND 15 NOT A PART OF THIS DRAWING SPECIFICATIONS. WALL THICKNESS SHALL PROVIDE CODE COVER OVER REINFORCING. FOR OVER 8'-0" A SPECIAL DESIGN WILL BE REQUIRED. 16. RESIDENTIAL POOLS SHALL COMPLY WITH THE ANSI/APSP/ICG-5 2011 FOR RESIDENTIAL INGROUND POOLS, ANS VAPEP/ICO-5 2014 FOR PERMANENTLY INSTALLED RESIDENTIAL SPAS, AND AN5I/AP5P/ICC-1 2013 FOR SUCTION ENTRAPMENT AVOIDANCE STANDARDS. AND ANSVAPSFACC-15A 2013 STANDARD FOR RESIDENTIAL SWIMMING POOL AND SPA ENERGY EFFICIENCY 11. DO NOT USE OR OPERATE POOL OR SPA IF THE SUCTION FITTING 15 MISSING, BROKEN, OR L005E. 18. IF THE SUCTION INLET SYSTEM, SUCH AS AN AUTOMATIC CLEANING SYSTEM, IS A VACUUM GLEANER SYSTEM WHICH HAS A SINGLE SUCTION INLET, OR MULTIPLE SUCTIONS INLETS WHICH CAN BE ISOLATED BY VALVES, THEN EACH SUCTION INLET SHALL PROTECT AGAINST USER ENTRAPt`i-ENT BY EITHER AN APPROVED ANTI -VORTEX COV -ER, 12" X 12" GRATE OR LARGER, OR OTHER APPROVED MEANS. COMPACTED SOIL UNDER FAR<ER i" iYNCNENSERG 4 ASSOC. INC CONCRETE DECK 11 PROFESSIONAL ENGINEERS LANDSCAPE ARCHITECTS 112q RIDGEWOOD AVENUE HOLLY HILL FLORIDA 32111 (386) 6-17-6881 FAX (386) 6*71-2114 NOT VALID WITHOUT EMBOSSED SEAL. - s ,��� '�- G FEB PARKER 1-1 PEN15EROP,E: X32645 TYFICAL RESIDENTAL SN/POOL DESIGN FOP, SURF51 DE POOLS 313 BEACH BOULEVARD JACKSONVILLE BEACH, FL. 32250 (904) 246-2666 STATE LICENSE OF0044080 THIS SIGNED AND SEALED SHEET IS TO BE USED AS A MASTER FILE COPY . IT WILL BE USED FOR A MAXIMUM PERIOD OF ONE YEAR EXPIRING ON 12/31/18. IF THE FLORIDA BUILDING CODE IS ALTERED OR MODIFIED BEFORE THAT DATE, THIS DRAWING MAY BE RENDERED VOID. SHEET I OF 5