Loading...
631 Beach Ave RESA18-0033 dwgs 2DESIGN SPECIFICATIONS GENERAL NOTES Et CONSTRUCTION SPECIFICATIONS DESIGN CODE: TRIBUTARY AREA (sf) INTERIOR EDGE STRIP (PSF): ZONE (PSF) 2017 FLORIDA BUILDING CODE - RESIDENTIAL 10 +30.2 -32.9 +30.2 -40.5 DESIGN IS VOID ONE YEAR AFTER THE DATE OF THE ORIGINAL PLANS, +25.7 -28.2 UNLESS PLANS HAVE BEEN REVIEWED FOR CODE COMPLIANCE. DESIGN LOADS: ACTUAL AND UNIFORM Z m � ROOF FLOOR ROOF LOADING (cd=1.25) (cd=1.00) TOP CHORD LIVE LOAD 20 psf 40 psf TOP RD DEAD LOAD 7 f ARCH SHINGLES 10 sf COMPONENTS & CLADDING ALLOWABLE DESIGN PRESSURES TRIBUTARY AREA (sf) INTERIOR EDGE STRIP (PSF): ZONE (PSF) 'a' = 4'-6" 10 +30.2 -32.9 +30.2 -40.5 50 +27.1 -29.6 +27.1 -34.2 100 +25.7 -28.2 +25.7 -31.2 FLOOR SHEATHING SPECIFICATIONS 23/32" T&G OSB OR PLYWOOD SHEATHING, GLUE AND NAIL WITH 10d COMMON @ 6" O.C. EDGE & FIELD ROOF SHEATHING SPECIFICATIONS: SHINGLE- MIN. 7/18 ", 24/16, APA RATED OSB OR PLYWOOD SHEATHING, NAILED w/ 0.113x2" RING SHANK NAILS @ 6" O.C. EDGE & 6" O.C. FIELD (AT GABLE ENDS DECREASE EDGE NAIL SPACING TO 4" O.C. WITHIN 4'-0" OF ROOF EDGE). WALL SHEATHING SPECIFICATIONS: FLEXIBLE FINISH -MIN. 7/j,", 24/16, APA RATED OSB OR PLYWOOD SHEATHING, FASTENED w/ 8d @ 6" O.C. EDGE AND 6" O.C. FIELD. SHEATHING MAY BE INSTALLED HORIZONTALLY OR VERTICALLY. FLEXIBLE FINISH WALLS INCLUDE: WOOD, CEMENT, OR VINYL SIDING, HARDI PANEL & BRICK. ALL OTHER WALL SHALL BE CONSIDERED BRITTLE FINISH. P 1-1 ( TOP CHORD DEAD LOAD 20 psf (TILE SHINGLES) 10 psf STUCCO FINISH -MIN. 7/16 24/16, APA RATED OSB OR PLYWOOD SHEATHING, FASTENED w/ 8d @ 6" O.C. EDGE AND 6" O.C. FIELD. INSTALL SHEATHING WITH THE LONG DIMENSION P BOTTOM CHORD LIVE LOAD 10 psf 0 psf THE VALUES ABOVE ARE ALLOWABLE WIND PRESSURE VALUES (ASD). THE STUDS PERPENDICULAR TO THE WALL BOTTOM CHORD DEAD LOAD 5 psf 5 psf ABOVE WIND PRESSURES HAVE BEEN REDUCE BY 0.60 AS PERN41TTED BY THE ALLOWABLE STRESS DESIGN METHODOLOGY. NO FURTHER REDUCTION MASONRY SPECIFICATIONS: DEFLECTION CRITERIA: SHALL BE PERMITTED MASONRY HAS BEEN DESIGNED IN ACCORDANCE WITH ACI 530-05, AND SHALL BE CONSTRUCTED IN ACCORDANCE WITH AC153 0.1-05. GROUT SHALL BE IN ACCORDANCE WITH ASTM C476 WITH A MINIMUM OF 28 ROOF FRAMING: LIVE LOAD L/240 TOTAL LOAD L/180 DAY COMPRESSIVE STRENGTH OF 2000 psi PER ASTM C1019, GROUT SHALL HAVE A MAXIMUM COURSE AGGREGATE SIZE OF /8 PLACED AT AN 8 TO 11" SLUMP. MORTAR SHALL CONFORM TO ASTM C270 AND FLOOR FRAMING: LIVE LOAD L/360 & TOTAL LOAD L/240 COMPONENT &CLADDING WALL ELEMENTS SHALL BE DESIGNED FOR BOTH TYPE M OR S. TYPE N MORTAR MAY BE USED IN BRICK VENEER. CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND INSTALLATION OF ALL FLASHING. POSITIVE AND NEGATIVE PRESSURES SHOWN IN TABLE ABOVE. WIND LOADING: CONCRETE MASONRY UNITS (CMU): ASCE 7/10 FOR WIND UPLIFT, TRUSSES SHALL BE DESIGNED WITH A 0 LINEAR INTERPOLATION IS PERMISSIBLE. CMU SHALL BE IN ACCORDANCE WITH ASTM C90-75, HOLLOW LOAD-BEARING (CMU), TYPE 1, GRADE N-1, NORMAL WEIGHT, WITH A MINIMUM COMPRESSIVE STRENGTH OF 1900 psi (f'm=1500 psi). GROUT ALL MIN. DEAD LOAD CONDITION OF 5 PSF TOP CHORD AND 5 PSF CELLS CONTAINING VERTICAL REINFORCEMENT IN 5-0" MAXIMUM LIFTS PROVIDE CLEANOUTS PER ACI 530.1-02 IN THE BOTTOM OF COURSE OF MASONRY WHEN THE WALL HEIGHT EXCEEDS 5-0". BOTTOM CHORD. REACTIONS CALCULATED FOR THE BEARING POINTS 0 PLUS = PRESSURE AND MINUS = SUCTION. OF ROOF TRUSSES SHALL BE REDUCED. SPECIFICALLY, ATTIC FLOOR MASONRY STEMWALLS: ALL CONCRETE MASONRY UNITS SHALL BE COMPOSED OF ASTM C90E, E GRADE N-1 HOLLOW CONCRETE MASONRY UNITS WITH TYPE 'S' MORTAR. WALL COURSING SHALL BE RUNNING BONDS, .LIVE LOADS COMBINED WITH ROOF LIVE LOADS SHALL BE MULTIPLIED 0 DESIGN OF WINDOWS/DOORS FASTENING TO THE WALL FRAMING IS THE STACK BOND SHALL NOT BE USED. GROUT ALL CELLS CONTAINING VERTICAL REINFORCEMENT WITH 3000 PSI PEA ROCK CONCRETE GROUT. SPLICES IN REINFORCING, WHERE PERMITTED SHALL BE 4 BY 0.75. WHEN COMBINED w/ DEAD LOAD. RESPONSIBILITY OF THE WINDOW/DOOR MANUF./SUPPLIER & SHALL MEET 8 BAR THE ABOVE NOTED POSITIVE AND NEGATIVE PRESSURES. DIAMETERS. ALL EXTERIOR WALLS SHALL BE REINFORCED FULL HEIGHT WITH - #4 @ 4'-0" O.C. MAX. AND AT EACH CORNER, WALL END, AND WALL INTERSECTIONS. PROVIDE CONTINUITY OF REINFORCING AT BASIC WIND SPEED (ASCE 7-10) -------------- 130 MPH INTERSECTIONS OF PERPENDICULAR MASONRY ELEMENTS BY INSTALLING CORNER BARS, MINIMUM OF 40 BAR DIAMETERS INTO EACH ELEMENT. AT STEMWALL CONSTRUCTED OF 5 OR MORE COURSES PROVIDE IMPORTANCE FACTOR ----------------- --- 1.00 HORIZONTAL JOINT REINFORCEMENT AT 16" O.C. VERTICALLY, (EVERY OTHER COURSE), AND VERTICAL REINF. SHALL BE INCREASED AS NOTED ON 1/S1.0. UNLESS NOTED OTHERWISE. LAP JOINT REINFORCING SHALL MEAN ROOF HEIGHT ----------------------- EXISTING 1a Ik ek a zk BE A MINIMUM OF 6". ROOF PITCH - - - - - - - - - - - - - - - - - - - - - - - - - - - - VARIES � ---14-24-CLAY MASONRY (BRICK): a BUILDING CATEGORY ----------------------- BRICK SHALL BE IN ACCORDANCE WITH AS 'M C62, C216, OR C652 FOR BUILDING BRICK, FACING BRICK, & HOLLOW BRICK, RESPECTFULLY. EXPOSURE CATEGORY - - - - - - - - - - - - - - - - - - - - - - D CONCRETE SPECIFICATIONS: ENCLOSURE CLASSIFICATION -----------------ENCLOSED DENOTES EDGE STRIP. ALL CONCRETE H«AS BEEN DESIGNED IN ACCORDANCE WITH ACI 318-08, AND SHALL BE CONSTRUCTED IN ACCORDANCE WITH ACI 301. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI INTERNAL PRESSURE COEFFICIENT -------------- f .18 ;"" SEE C & C CHART AT 28 DAYS CONCRETE AT GARAGE AND PORCH SLABS SHALL HAVE A COMPRESSIVE STRENGTH OF 3000 PSI. ABOVE FOR 'a' DIMENSION GENERAL NOTES: MATERIAL SPECIFICATIONS FOOTING AND FOUNDATIONS: -- FOOTINGS AND FOUNDATIONS SHALL BE IN ACCORDANCE WITH LOCAL BUILDING CODES. FOOTING HAVE BEEN DESIGNED WITH A SOIL BEARING (DESIGN MAXIMUM) OF 2000 PSF. A SOILS INVESTIGATION REPORT IS 7r 7r RECOMMENDED TO VERIFY SUITABLE SUBSURFACE CONDITIONS. IF THE FOOTING ELEVATIONS SHOWN OCCUR IN A DISTURBED OR UNSTABLE SOIL, THE ENGINEER SHALL BE NOTIFIED. SOIL SHALL BE FREE OF a ORGANIC MATERIAL AND COHE DIVE (CLAY) SOILS. SOIL COMPACTION AND FILL SHALL BE COMPACTED TO A MIN. OF 95% MODIFIED PROCTOR IN ACCORDANCE WITH ASTM D 1557. HARDWARE AND ANCHORS: o ANCHOR BOLTS &THREADED ROD: SHALL BE IN ACCORDANCE WITH FOUNDATION PLAN ONLY CONVEYS STRUCTURAL INFORMATION. FOR GENERAL FEATURES, CONDUITS, ELECTRICAL EMBEDS, STEP HEIGHTS, ETC., SEE ARCHITECTURAL PLANS. DO NOT SCALE FOOTING DIMENSIONS AND ASTM A 307 OR ASTM F 1554 GRADE 36. [NOT ACTUAL PLAN] 7r a 2r 'a'r LOCATION FROM THE FOUNDATION PLAN SHOWN ON S1.0. DO NOT DETERMINE FOOTING LOCATION BASED ON EITHER THE ARCHITECTURAL PLAN OR FRAMING PLAN, BUT BY DIMENSIONS PROVIDED ON FOUNDATION WASHERS: SHALL BE IN ACCORDANCE WITH ASTM A500 (GRADE B). PLAN. IF FOOTING SIZE OR LOCATION IS NOT DETERMINED ON PLAN THEN CONTACT ENGINEER OF RECORD (EOR) NUTS: SHALL BE IN ACCORDANCE WITH ASTM A 563 GRADE A HEX. METAL CONNECTORS: ALL METAL CONNECTORS WHICH ARE EXPOSED TO UNLESS OTHERWISE NOTED ON DRAWINGS, MINIMUM CONCRETE COVER FOR REINFORCING SHALL BE 3" IN FOOTINGS AND MESH SHALL BE CENTERED 1N SLAB ON GRADE. IN ALL CONTINUOUS FOOTINGS PROVIDE 3 EXTERIOR SHALL BE GALVANIZED. # RETROFIT REBAR/ROD INSTALLATION: EMBEDMENT OF RODS OR REBAR SCOPE OF SERVICE @ 48" O.C. OR ROD CHAIRS. PROVIDE CONTINUITY OF REINFORCING AT INTERSECTIONS OF PERPENDICULAR CONCRETE ELEMENTS BY INSTALLING CORNER BARS, MINIMUM OF 40 BAR DIAMETERS INTO EACH ELEMENT. SPLICES IN REINFORCING, WHERE PERMITTED, SHALL BE 48 BAR DIAMETERS DOWELS SHALL BE 12 BAR DIAMETER MINIMUM, HOLES SHALL BE 1/4" LARGER THAN REBAR SIX AND 1/8" LARGER THAN THREADED ROD SIZE. MEANS AND METHODS: WOOD FRAMING SPECIFICATIONS: (U.0.N.) THE STRUCTURAL ENGINEER SHALL NOT HAVE CONTROL OR BE RESPONSIBLE ALL WOOD FRAMING HAS BEEN DESIGNED IN ACCORDANCE WITH NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION, LATEST EDITION. ALL WOOD MEMBERS EXPOSED TO WEATHER OR IN CONTACT ANCHORING ADHESIVE. SHALL BE ONE OF THE FOLLOWING PRODUCTS FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES, OR WITH MASONRY, CONCRETE OR SOIL SHALL BE PRESSURE -TREATED. IF, ACQ OR NON -DOT BORATE PRESERVATIVE TREATMENT IS USED, ALL ATTACHED FASTENERS SHALL BE HOT DIPPED GALVANIZED. IF ACZA (DUAL CARTRIDGE INSTALLATION ONLY). SEQUENCES; FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR OR ANY PRESERVATIVE IS USED, ALL ATTACHED FASTENERS SHALL BE STAINLESS STEEL. EPDXY: ITW RED HEAD A7 OTHER PERSONS PERFORMING THE WORK OR FOR THE FAILURE FOR ANY OF REINFORCING STEEL: SHALL BE ASTM A615, GRADE 60. THEM TO CONSTRUCT THE WORK IN ACCORDANCE WITH THE CONTRACT PRE-ENGINEERED WOOD TRUSSES: STRUCTURAL STEEL: SHALL BE ASTM A992, GRADE 50. DOCUMENTS. SHALL BEAR THE SEAL OF AN ENGINEER IN THE STATE WHERE PROJECT IS BEING BUILT AND SHALL COMPLY WITH NEPA, TPI, AND AITC 100. CONTRACTOR SHALL VERIFY THAT ADEQUATE TRUSS BEARING IS WELDED WIRE FABRIC (WWF): SHALL BE ASTM A185. INSTALLED AT ALL TRUSSES AS 1";- ICATED IN THE TRUSS SHOP DRAWINGS. ALL TRUSS -TO -TRUSS CONNECTIONS AND TRUSS PROFII.._ES ARE THE RESPONSIBILITY OF THE DELEGATED TRUSS ENGINEER. ALL LIMITS OF STRUCTURAL ENGINEERING DESIGN RESPONSIBILITIES. THE ITEMS SPECIFICALLY DESIGNED BY THE STRUCTURAL ENGINEER ARE LAMINATED VENEER LUMBER (LVL): ALL LAMINATED VENEER LUMBER TRUSSES SHALL HAVE TEMPORARY BRACING PER COMMENTARY' AND RECOMMENDATION FOR HANDLING, INSTALLING & BRACING METAL PLATE CONNECTED WOOD TRUSSES, HIB -91." AT MULTIPLE STRAP SHALL MEET OR EXCEED THE FOLLOWING DESIGN PROPERTIES - ELASTIC LIMITED TO THE FOLLOWING: CONTINUOUS LOAD PATH FOR WIND UPLIFT, CONNECTIONS, SPREAD STRAPS TO AVOID NAILING CONFLICTS THROUGH TRUSS. WHEN USING (2) STRAPS ON SINGLE PLY TRUSSES, PLACE STRAPS DIAGONALLY ACROSS DBL. TOP PLATE FROM EA. OTHER. MODULUS (E)1,900ksi, BENDING STRESS (Fb) 2600psi WOOD PANEL SHEARWALLS, WALL FRAMING AND REQUIRED SHEATHING AND HEADERS DIRECTLY SUPPORTING ROOF FRAMING. ITEMS NOT DESIGNED ROOF COVERING SPECIFICATIONS: PRE-ENGINEERED WOOD FLOOR AND ROOF TRUSSES, FLOOR FRAMING NOT THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND INSTALLATION OF THE ROOF COVERING SYSTEM. ASPHALT SHINGLES SHALL COMPLY WITH ASTM D3161 AND BE INSTALLED ACCORDING TO THE SPECIFICALLY ADDRESSED, TRUSS -TO -TRUSS CONNECTION, AND ANY MANUFACTURER'S REQUIREMENTS. CLAY AND TILE ROOFS SHALL BE INSTALLED PER THE "CONCRETE AND CLAY ROOF TILE INSTALLATION MANUAL." AND THE MANUFACTURER'S REQUIREMENTS. STANDING SEAM ARCHITECTURAL, MECHANICAL OR ELECTRICAL SYSTEM. METAL ROOFS SHALL COMPLY WITH ASTM E1514 AND BE INSTALLED ACCORDING TO THE MANUFACTURER'S REQUIREMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND INSTALLATION OF ALL METAL FLASHING AND VALLEY MATERIALS. WATERPROOFING: THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN/INSTALLATION OF ALL WATER PROOFING. PRE-ENGINEERED MISCELLANEOUS STRUCTURES: ANY EYEBROW, CANOPY, ALUMINUM COMPONENT OR ANY OTHER BUILDING APPENDAGES NOT SPECIFICALLY DETAILED HEREIN SHALL BE DESIGNED BY OTHERS AT THE EXPENSE OF THE CONTRACTOR. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF MISCELLANEOUS ATTACHED STRUCTURES TO THE MAIN STRUCTURE INDICATING CONNECTION POINTS, REACTIONS AND FASTENER REQUIREMENTS PRIOR TO FABRICATION OF MISCELLANEOUS STRUCTURE AND PRIOR TO CONSTRUCTION OF MAIN STRUCTURE. CONTRACTOR SHALL COORDINATE LOADING REQUIREMENTS WITH ANY OTHER PRE-ENGINEERED COMPONENT SUCH AS ROOF FLOOR AND ROOF TRUSS ENGINEERING. SIMPSON CONNECTORS WOOD FASTENING SCHEDULE PLAN LEGEND AND ABBREVIATIONS UPLIFT MEMBERS CONNECTION FASTENER INTERIOR LOAD BEARING WALL CONNECTOR SYP SPF FASTENERS FL# CODE TYPE ® BUILT-UP POST IN THE WALL TOP PLATE TO TOP PLATE FACE NAIL 2 -GUN NAILS @ 12" STAG. A35 450 450 12-8dx11/2 10446.4 GABLE X -BRACE H2.5T 600 520 5-8d EA. END 11478.3 TOP PLATE, LAPS/INTERSECTION FACE NAIL (2-16d) 3 -GUN NAILS H6-1 /2 HEADER SIZE, JACK AND KING STUD DBL. TOP PLATE TO STUD FACE NAIL (2-16d) 3 -GUN NAILS --- DESIGNATES SHEARWALL. THE QUANTITY. H8 620 530 5-10dx11/2" EA. END 11470.3 __.,_ HIDDEN LINE DESIGNATES SIDE OF RIM JOIST TO TOP PLATE TOE NAIL (8d @ 6") GUN NAIL @ 6"SW WALL THE SHEARWALL SHEATHING MTS12 1000 860 7-10dx11/2" EA. END 10456.3 TO BE APPLIED. 8d 0 3/6 NG: NAILING: CEILING JOIST TO TOP PLATE TOE NAIL (3-8d) 5 -GUN NAILS DESIGNATES 8d COMMONS @ 3" HTS20 1450 1245 24-10dx1 /2 EA. END 13872.3 8d@3' 6 O.C. EDGE & 6" O.C. "IN THE MSTA24 1765 1270 9-10d EA. END 13872.4 CEILING JOIST, OVER PARTITIONS FACE NAIL (3-16d) 4 -GUN NAILS FIELD" CEILING JOIST TO ROOF RAFTER FACE NAIL (6-16cl) 8 -GUN NAILS MSTA36 2050 1870 13-1Od EA. END 13872.8 ADJ - ADJACENT LG - Long 18-16d TO TRUSS/BEAM JOIST/TRUSS TO PLATE TOE NAIL (2-16d) 3 -GUN NAILS BM - BEAM MANUF - Manufacture HTT4 3480 3080 11496.2 RAFTER TO PLATE TOE NAIL 3-8d 3 -GUN NAILS BOT - BOTTOM MONO - Monolithic 1-5/B"� ROD TO FTG. ( ) BRG - BEARING OC - On Center 32-16d TO TRUSS/BEAM JACK RAFTER TO HIP TOE NAIL (3-10d) 4 -GUN NAILS CMU - CONCRETE MASONRY UNIT OSB - Oriented Strand Board HTT5 5250 4670 5 11496.2 DBL - DOUBLE PERP - Perpendicular 1- /8 b ROD TO FTG. ROOF RAFTER TO 2x- RIDGE BM. TOE NAIL (2-16d) 3 -GUN NAILS DIA - DIAMETER PRE ENG - Pre Engineered 6-10d TO HEADER CONT. HEADER, TWO PIECES FACE NAIL 16d@ 16" O.C. @ EDGE EA - EACH PSF - Pounds per Square Foot 4-10d TO JOIST LUS28 930 780 10655.113 EE - EACH END PSI - Pounds PSquare er Inch CONT. HEADER TO STUD TOE NAIL (3-16d) 4 -GUN NAILS EOR - ENGINEER OF RECORD PT - PRESSURE TREATED 6e; 14-16d `ars 14-16d TO HEADER STUD TO SOLE PLATE TOE NAIL 3-16d 4 -GUN NAILS EQ - EQUAL QT - Quick Tie HU410 905 785 10531.36 ( ) EXT - EXTERIOR REINF - Reinforce 6-16d TO JOIST SOLE PLATE TO JOIST BLOCKING FACE NAIL " FBC - FLORIDA BUILDING CODE SF - Square Foot 5 / (16d @ 16) GUN NAIL @ 8 FDN - FOUNDATION SPF Spruce Pine Fur v ABU44 2200 /8 � ROD w/ 12-16d 10849.6 -Spruce � ABU66 2300 5/8"0 ROD w 12-16d 10849.6 FT - FOOT SYP - Southern Yellow Pine / NAIL SPECIFICATIONS FTG - FOOTING THRU - Through SET N/A N/A SIMPSON EPDXY-TIE 11506.4 3"x0.131"O = GUN NAILS 2"xO.113"O = RINK SHANK HDR - HEADER TYP - Typical "HORIZ - HORIZONTAL UON - Unless Otherwise Noted 2"x0 113"�3 = 6d 21/2x0.131 "4� = 8d °^ 10-16d TO STUD/BEAM/POST LBS - POUNDS VERT - Vertical roe's„ LTT20B 1675 1675 11496.3 3"x0 148"O = 10d 3/2%0.162"0 = 16d WWF - Welded Wire Fabric 1-1/,"0 ROD TO FTG. 11/2 "x0.148"O = 10dx11/2 " 11/2 "x0.131 "O = 8dx11/2 " LSTA12 805 695 10-10d 13872.5 CS16 1705 1705 13-8d 10852.1 420 Osceola Avenue Jax. Beach, Florida 32250 Ph. 242-0908 Fax. 241-9557 FL: CA # 8344 SC: CA# 3579 N 311 E STAT Al QJN 'f71 itl tl,J" Luis A. PgwCi o, PE FL Pl #"k' 3311 REVISIONS DATE FIELD ALTERATION CONTRACTOR SHALL CONTACT LOU PONTIGO E ASSOCIATES PRIOR TO MAKING ANY STRUCTURAL FIELD MODIFICATIONS WHICH MAY VARY FROM THE INTENT OF THE ORIGINAL CONSTRUCTION DOCUMENTS. ANY FIELD ALTERNATIONS MADE PRIOR TO BEING APPROVED BY LOU PONTIGO @ ASSOCIATES MAY RESULT IN ADDITIONAL ENGINEERING OR INSPECTION FEES. W -� UU.zw o Q Q W= w m �QU Z m � 4< 2 Q DESIGN CRITERIA AND GENERAL NOTES DO NOT SCALE DIMENSIONS FROM THESE DRAWINGS. IF A DIMENSION IS UNCLEAR REFER TO THE ARCHITECTURAL DRAWINGS OR CONTACT THE E.O.R. PLAN NAME RESIDENCE DESIGN/DRAWN/CHECKED JMD MJK /LAP DATE 12/04/18 SCALE AS NOTED LPA No. CONTROL No. SHEET S0.0 SHEET 1 OF 5 FIRST LEVEL WALL FRAMING PLAN SCALE: 1/4" = 1'-0" HU210-2 OR HUC210-2 HANGER FASTEN TO SOLID WOOD HU210-2 OR HUC210-2 HANGER FASTEN TO SOLID WOOD C9 STRAP BEAM TO POST PER 3/S2.0 LIJS210-2 HANGER 6x6 P.T. SYP#2 POST S!7 --E DETAIL 1 /S2.0. (TYPICAL) FySTEN BEAM TO POST PIER 7/S2.0 EN BEAM TO POST 7/S2.0 US210-2 HANGER I STRAP BEAM TO POST PER 3/S2.0 EXISTING STRUCTURES ARE SHOWN ON DRAWINGS FOR CLARITY ONLY. VERIFY ALL EXISTING, NEW ELEVATIONS AND TYPE OF CONSTRUCTION OF THOSE STRUCTURES, AND NOTIFY ENGINEER IMMEDIATELY BEFORE BEGINNING NEW CONSTRUCTION OF ANY INTERFERENCES AND/OR DISCREPANCIES THAT MIGHT EXIST BETWEEN CONSTRUCTION DOCUMENTS AND/OR ACTUAL FIELD CONDITIONS. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY BRACING/SHORING, TEMPORARY SUPPORTS AND OTHER SUCH ITEMS OR OTHER MEASURES NECESSARY TO PROTECT THE STRUCTURE AND ANY PERSONNEL DURING CONSTRUCTION. THE DESIGN ADEQUACY AND SAFETY OF ABOVE ITEMS ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 2x6 SYP#2 LEDGER. FASTEN w/ (5)1 Ud (9 'lb U. U. DECK AND LOW ROOF FRAMING PLAN SCALE: 1/4" = 1'-0" -E: WATERPROOFING IS THE SOLE RESPONSIBILITY OF THE BUILDER SLOPE DECK '/4" PER 1'-0" ALL WOOD MEMBERS LESS THAN 18" ABOVE GRADE SHALL BE P.T. MATERIAL ALL EXPOSED METAL CONNECTORS SHALL BE S.S. OR H.D.G. SYP#2 LEDGER. FASTEN W/ (5)10d & "Ox5" LAG SCREWS @ 16" O.C. 3LE FULL DEPTH OARD SYP#2 DECK FS @ 16" 0. C. 420 Osceola Avenue Jax. Beach, Florida 32250 Ph. 242-0908 Fax. 241-9557 FL: CA # 8344 SC: CA# 3579 !tillti te('f�9flfl \_ (D No 311 S TATE iif (il Viii lilt t Luis A. Pi)s ttigo, PE FL PE#53311 REVISIONS DATE I I I FIELD ALTERATION CONTRACTOR SHALL CONTACT LOU PONTIGO & ASSOCIATES PRIOR TO MAKING ANY STRUCTURAL FIELD MODIFICATIONS WHICH MAY VARY FROM THE INTENT OF THE ORIGINAL CONSTRUCTION DOCUMENTS. ANY FIELD ALTERNATIONS MADE PRIOR TO BEING APPROVED BY LOU PONTIGO 8 ASSOCIATES MAY RESULT IN ADDITIONAL ENGINEERING OR INSPECTION FEES. I W U J LL Z LLJ LLJ > ❑ Q U Lf) = W CO 12 < U Z m � pmQ I Q FOUNDATION a WALL FRAMING PLAN DO NOT SCALE DIMENSIONS FROM THESE DRAWINGS. IF A DIMENSION IS UNCLEAR REFER TO THE ARCHITECTURAL DRAWINGS OR CONTACT THE E.O.R. PLAN NAME RESIDENCE DESIGN/DRAWN/CHECKED JMD / MJK LAP DATE 12/04/18 SCALE AS NOTED LPA No. CONTROL No. SHEET SM SHEET 3 OF 5 FOUNDATION PLAN SCALE: 1/4" = 1'-0" ;T SEE EXISTING STRUCTURES ARE SHOWN ON DRAWINGS FOR CLARITY ONLY. VERIFY ALL EXISTING/NSW ELEVATIONS AND TYPE OF CONSTRUCTION OF THOSE STRUCTURES, AND NOTIFY ENGINEER IMMEDIATELY BEFORE BEGINNING NEW CONSTRUCTION OF ANY INTERFERENCES AND/OR DISCREPANCIES THAT MIGHT EXIST BETWEEN CONSTRUCTION DOCUMENTS AND/OR ACTUAL FIELD CONDITIONS. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY BRACING/SHORING, TEMPORARY SUPPORTS AND OTHER SUCH ITEMS OR OTHER MEASURES NECESSARY TO PROTECT THE STRUCTURE AND ANY PERSONNEL DURING CONSTRUCTION. THE DESIGN ADEQUACY AND SAFETY OF ABOVE ITEMS ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. NOTE: 1. WATERPROOFING IS THE SOLE RESPONSIBILITY OF THE BUILDER 2. SLOPE DECK 1/4" PER 1'-0" 3. ALL WOOD MEMBERS LESS THAN 18" 2x12 SYP#2 LEDGER. FASTEN OFF -GRADE FRAMING PLAN SCALE: 1/4" = 1'-0" TITEN HD Q 16" O.C. 210-2 HANGER SYP#2 DECK JOISTS 3" 0. C. (TYP) 12-3 HANGER 210-2 HANGER SYP#2 DECK JOISTS i" 0. C. (TYP) J BEAM TO POST /S2.0 (TYP) 210-2 HANGER 2-3 HANGER SYP#2 DECK JOISTS 0. C. (TYP) 210-2 HANGER 420 Osceola Avenue )ax. Beach, Florida 32250 Ph. 242-0908 Fax, 241-9557 FL: CA # 8344 SC: CA# 3579 4+ ,�`t�Vi7fifl El]tt ttt `,V' \�,"`_ �,`� • °`?tel. N !.311 t� c STATE= r '4 tilt ' • • ' • ,��`>� �J Luis A. PM1,6q, PE FL P E )It' 3 31 1 REVISIONS DATE FIELD ALTERATION CONTRACTOR SHALL CONTACT LOU PONTIGO 8 ASSOCIATES PRIOR TO MAKING ANY STRUCTURAL FIELD MODIFICATIONS WHICH MAY VARY I FROM THE INTENT OF THE ORIGINAL CONSTRUCTION DOCUMENTS. ANY FIELD ALTERNATIONS MADE PRIOR TO BEING APPROVED BY LOU PONTIGO 8 ASSOCIATES MAY RESULT IN ADDITIONAL ENGINEERING OR INSPECTION FEES. w U J LL Z Lij LLJ U Q w = w m U < Uz m F_ Z O:D �� I Q FOUNDATION & OFF -GRADE FRAMING PLAN DO NOT SCALE DIMENSIONS FROM THESE DRAWINGS. IF A DIMENSION IS UNCLEAR REFER TO THE ARCHITECTURAL DRAWINGS OR CONTACT THE E.O.R. 1 r ---PLAN NAME RESIDENCE DESIGN/DRAWN/CHECKED JMD / MJK /LAP DATE 12/04/18 SCALE AS NOTED LPA No. CONTROL No. SHEET 1S.0 SHEET 2 OF rj SECOND LEVEL WALL FRAMING PLAN SCALE: 1/4" = 1'-0" x6 P.T. SYP#2 OST STRAP TO ELOW w/ 4—CS16 TRAP BEAM TO POST ER 3/S2.0 (TYP) C 1 i EXISTING STRUCTURES ARE SHOWN ON DRAWINGS FOR CLARITY ONLY. VERIFY ALL EXISTING/NEW ELEVATIONS AND TYPE OF CONSTRUCTION OF THOSE STRUCTURES, AND NOTIFY ENGINEER IMMEDIATELY BEFORE BEGINNING NEW CONSTRUCTION OF ANY INTERFERENCES AND/OR DISCREPANCIES THAT MIGHT EXIST BETWEEN CONSTRUCTION DOCUMENTS AND/OR ACTUAL FIELD CONDITIONS. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY BRACING/SHORING, TEMPORARY SUPPORTS AND OTHER SUCH ITEMS OR OTHER MEASURES NECESSARY TO PROTECT THE STRUCTURE AND ANY PERSONNEL DURING CONSTRUCTION. THE DESIGN ADEQUACY AND SAFETY OF ABOVE ITEMS ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. ROOF FRAMING PLAN SCALE: 1/4" = 1'-0" 12 SYP#2 ROOF ,FTERS @ 24" O.C. 4 SYP#2 OUTLOOKERS @ 24" O.C. )2x4 SPF#2 KING POST. STRAP P AND BOTTOM w/ (2)HTS16 �E 420 Osceola Avenue Jax. Beach, Florida 32250 Ph. 242-0908 Fax. 241-9557 FL: CA # 8344 SC: CA# 3579 ' (D No. 3 S TA 0, �g F S ..001 F Luis A. Pontigo, PE FL PE#53311 K—iREVISIDNS DATE FIELD ALTERATION CONTRACTOR SHALL CONTACT LOU PONTIGO @ ASSOCIATES PRIOR TO MAKING ANY STRUCTURAL FIELD MODIFICATIONS WHICH MAY VARY FROM THE INTENT OF THE ORIGINAL CONSTRUCTION DOCUMENTS. ANY FIELD ALTERNATIONS MADE PRIOR TO BEING APPROVED BY LOU PONTIGO 8 ASSOCIATES MAY RESULT IN ADDITIONAL ENGINEERING OR INSPECTION FEES. w � U W LIJ > _ ° Qa w = w m ry U < Uz m � Z 2 Q SECOND LEVEL WALL FRAMING a ROOF FRAMING PLAN DO NOT SCALE DIMENSIONS FROM L DRAWINGS. IF A DIMENSION IS NCLEAR REFER TO THE ITECTURAL DRAWINGS OR CONTACT THE E.O.R. r--7PLAN NAME RESIDENCE DESIGN/DRAWN/CHECKED JMD MJK LAP DATE 12/04/18 SCALE AS NOTED LPA No. CONTROL No. SHEET S12 SHEET 4 OF rj SHEATHING SPECS PONY WALL OVER BEAM PER 4/S2.0 BEAM PER PLAN FASTEN BEAM TO POST PER 3/S2.0 WRAP PORTION OF POST EMBEDDED BELOW GRADE W/ SELF—ADHESIVE RUBBERIZED ASPHALTIC WATERPROOFING POST PER MEMBRANE PLAN 7=77 7-- a 1—#4x16" REBAR, EA. WAY, DRILLED 20"Ox2'-0" DEEPI=1I o THROUGH POST CONCRETE "DONUT" FOUNDATION STABILIZED SUBGRADE, r NON—PLASTIC, INORGANIC, GRANULAR SOIL COMPACTED TO A DENSITY OF AT LEAST 95% MOF THE PROCTOR MAXIMUM DRY POST SPLICE @ TOP OF BEAM FASTEN POST FROM ABOVE TO BELOW w/ 2—CS16 @ 2—FACES OF POST POST SPLICE @ TOP OF BEAM FASTEN POST FROM ABOVE TO BELOW w/ 2—CS16 EA. END 6x6 SYP#2 P.T. POST SHEATHING PER SPECS OR DECKING BY BUILDER w/ 5/4" DECKING w/ (2)#8x3" DECK SCREWS AT EA. JOIST 'ULL DEPTH RIMBOARD "ASTEN BEAM TO POST w/ 3)5/8" S.S. THRU BOLTS BREAK—AWAY POST FOUNDATION PER //'_2/S2.0 TWO STORY 1 SCHEMATIC SECTION SCALE: 3/4" = 1'-0" DENSITY (ASTM D 1537) BREAKAWAY EMBEDDED POST DETAIL SCALE: 3/4" = 1'-0" EE 5/S2.0 EAM PER PLAN STEN BEAM TO ST PER 3/S2.0 <6 SYP#2 P.T. JLL HEIGHT POST SINGLE STORY ROOF RA. PER F 2x6 SYP#2 NAILER FASTENED TO TOP PLATE w/ 10d MSTA24 STRAP w PARALLEL TRUSS CONDITION pn<T OW I TS- ", 6 TRAP 2x6 SYP#2 1 tj BLOCKING BETWEEN _/ EA TRUSS. FASTEN TO TOP PLATE w/ j BEAM AND POST PERPENDICULAR 10d @ 3" O.C. I PER PLAN. TRUSS CONDITION FASTEN BEAM TO POST BASE: POST PER 4x4 POST: ABU44 DETAILS TO LEFT MSTA24 6x6 POST: ABU66 (TYP) STRAP 8x8 POST: ABU88 PORCH. SLAB H TS16 a STRAP 5/8"0 ROD EPDXIED 6" MIN PLAN VIEW OF PORCH PLAN VIEW OF PORCH ELEVATION OF PORCH BEAM AT CORNER POST BEAM AT CENTER POST BEAM AT POST NOTES: 1. SEE TABLE 8/SO.0 FOR PORCH CEILING SHEATHING SPECIFICATIONS 2. FASTEN TRUSS TO BEAM PER DETAIL 1/S2.1 (DISREGARD FULL HEIGHT ANCHOR ON DETAIL) 3. WATER PROOFING AT LOWER PORTION OF BOX COLUMN BY BUILDER IF PT MATARIAL IS NOT USED TYPICAL PORCH FRAMING SCALE: 3/4" = 1'-0" FASTEN RAFTER TO BEAM /LEDGER w/(5)10d TOENAILS. ROOF SHEATHING, SEE SO.0. UPLIFT CONNECTOR AND (2)12d TOENAILS EACH SIDE OF RAFTER. SHEATHING PER SPECS OR DECKING BY BUILDER w/ 5/4" DECKING w/ (2)#8x3" DECK SCREWS AT EA. JOIST FULL DEPTH RIMBOARD TO POST w/ RU BOLTS AWA" POST TION PER u ROOF RAFTER PER PLAN VAULTED CONVENTIONAL ROOF SCALE: 3/4"=1'-0" HUC212-2 HANGER (2)2x12 P.T. SYP#2 6EAM FULL HEIGHT 6x6 SYP#2 P.T. POST A35 ANGLE w m N 0- N X N r0 BEAM -TO -POST CONNECTION JUALL: .5/4 = I —U FASTEN RAFTER TO BEAM/LEDGER w/(5)10d TOENAILS. ROOF SHEATHING, SEE SO.0. X/z UPLIFT CONNECTOR AND lIFr—(2)12d TOENAILS EACH SIDE OF RAFTER, (3)5/,,"0 STAINLESS STEEL THRU BOLTS 2x4 SYP OUTLOOKER 24" 0. C. ROOF SHEATHING H3 AT 4-12d TOE EACH NAILS (2 EA OUTLOOKER SIDE) 2x4 BLOCKING BETWEEN OUTLOOKERS zz/ ROOF JOIST,/ SEE PLAN 4-12d TOE NAILS (2 EA SIDE) FACI A, SEE ARCH H3 0--/ RAKED 2x4 @ 16" 32" O.C. O.C. PONY WALL MSTA24 @ 32" O.C. HEADER PER PLAN i BALLOON FRAMED WALL OVER BEAM SHE THING PER SPECS OR DECKING BY BUILDER w/ 5/4" DECKING w/ (2)#8x3" DECK SCREWS AT EA. JOIST SLOPE =1/4" PER 1'-0" CHANGER PER PLAN PLEDGER PER PLAN TYPICAL DECK SECTION SCALE: 3/4" = 1'-0" HUC212-2 (3)5/,,"0 STAINLESS STEEL THRU BOLTS FULL DEPTH RIMBOARD PER PLAN H2.5T BEAM PER PLAN 420 Osceola Avenue Jax. Beach, Florida 32250 Ph. 242-0908 Fax. 241-9557 FL: CA # 8344 SC: CA# 3579 No. 5 C STATE Luis A. Pigo, PE FL PE#53311 REVISIONS DATE FIELD ALTERATION CONTRACTOR SHALL CONTACT LOU PONTIGO 8 ASSOCIATES PRIOR TO MAKING ANY STRUCTURAL FIELD MODIFICATIONS WHICH MAY VARY FROM THE INTENT OF THE ORIGINAL CONSTRUCTION DOCUMENTS. ANY FIELD ALTERNATIONS MADE PRIOR TO BEING APPROVED BY LOU PONTIGO 8 ASSOCIATES MAY RESULT IN ADDITIONAL ENGINEERING OR INSPECTION FEES. w � U Z> 0Q Q V) =w m< Uz LU0 Z omg =�Q FRAMING DETAILS DO NOT SCALE DIMENSIONS FROM THESE DRAWINGS. IF A DIMENSION IS UNCLEAR REFER TO THE ARCHITECTURAL DRAWINGS OR CONTACT THE E.O.R. PLAN NAME RESIDENCE DESIGN/DRAWN/CHECKED JMD MJK /LAP DATE 12/04/18 SCALE AS NOTED LPA No. CONTROL No. SHEET S2.0 SHEET rj OFrj