461 ATLANTIC BLVD. FIRE ALARM FIRE PERMIT PERMIT NUMBER mss ' ERES19-0029 CITY OF ATLANTIC BEACH u �~ 800 SEMINOLE ROAD ISSUED: 2/13/2019 N r c r EXPIRES: 8/12/2019 � 3 ATLANTIC BEACH. FL 32233 MUST CALL INSPECTION • • • 1 BY 4 PM FORDAY INSPECTION. ALL WORK MUST CONFORMTO THE CURRENT 6TH EDITION1 OF • ' ! BUILDING CODEI NEC, 1PMC, AND CITY OF ATLANTIC BEACH CODE OF ORDINANCES . ALL CONDITIONS OF PERMIT APPLY, PLEASE READ CAREFULLY. NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts,state agencies,or federal agencies. JOB ADDRESS: PERMITTYPE: DESCRIPTION: VALUE OF WORK: 461 ATLANTIC BLVD FIRE ALARM FIRE ALARM $4750.00 TYPE OF ! • • GROUP: 1706910010 SALTAIR SEC 03 COMPANY: ADDRESS: SECURITY ENGINEERING 3139 WALLER STREET JACKSONVILLE FL 32254 AND DESIGNS INC • ADDRESS: STATE: ATLANTIC BEACH YARD 1238 BEACH AVE ATLANTIC BEACH FL 32233 REAL ESTATE LLC WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. L LIST OF . ! • ,Roll off container company must be on City approved list . Container cannot be placed on City right-of-way. FEES DESCRIPTION ACCOUNT QUANTITY PAID AMOUNT ELECTRICAL BASE FEE 455-0000-322-1000 0 $55.00 STATE DBPR SURCHARGE 455-0000-208-0700 0 $2.00 STATE DCA SURCHARGE 455-0000-208-0600 0 $2.00 TOTAL: $59.00 Issued Date:2/13/2019 1 of 2 rSylyr�� City of Atlantic Beach APPLICATION NUMBER JS by Building Department (To be assigned by the Building Department.) Y � 800 Seminole Road on zc� Atlantic Beach, Florida 32233-5445 ERAS(9 Phone(904)247-5826 Fax(904)247-5845 E-mail: building-dept@coab.us Date routed: Z-4 41_c�___ City web-site: hftp://www.coab.us APPLICATION REVIEW AND TRACKING FORM /� - II I epartment review re uired Yes No Property Address: lA+�Qn`t'L(� _ L p uildin Applicant: Planning &Zoning II ,( --Tree Administrator Project: I re- `QrM c L/ S t�e Public Works Public Utilities Public Safety ' ervices Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: VApproved. ❑Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: 02- 1 tCk TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. ❑Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 Electrical Permit Application **ALL INFORMATION HIGHLIGHTED IN City of Atlantic Beach Building Department GRAY IS REQUIRED. 800 Seminole Rd, Atlantic Beach, FL 32233 Phone: (904) 247-5826 Email: Building-Dept@coab.us PERMIT#: JOB ADDRESS: A-rL-A-R r,g- I ivD PROJECT VALUE $ 40,50 tJC' ao-h 6 9 Q JEA INFORMATION REQUIRED ON ALL PERMITS: AMPS VOLTS PHASE ❑ NEW SERVICE: ❑Overhead ®Underground ❑Underground up Pole l7lResidential (Main)Service: I❑0-100 amps 1771101-150amps [1151-200amps []_amps # of Meters ❑Commercial (Main)Service: ❑0-100 amps 0101-150amps E1151-200amps © amps []CT Service amps Conductor Type Size I]Multi-Family(Main) Service: ❑0-100 amps 0101-150amps r7151-200amps ® amps # of Unit Meters ❑TEMPORARY POLE: amps ❑ SERVICE UPGRADE: ❑ amps ❑CT Service amps ❑ NEW FEEDER (ADDITIONS, ACCESSORY STRUCTURES, ETC.): ®100 amps ❑150amps ❑200amps ❑ amps ❑CT Service amps ❑ ADDITIONS, REMODELS, REPAIRS, BUILD-OUTS, ACCESSORY STRUCTURES, ETC: Outlets/Switches: 0-30amps 31-100amps 101-200amps Appliances: 0-30amps 31-100amps 101-200amps A/C Circuits: 0-60amps 61-100amps Heat Circuits: # circuits @ kw Number of Lighting Outlets, Including Fixtures: OTHER ELECTRICAL PROJECTS: ❑Swimming Pool ❑Sign []Smoke Detectors (Qty) ❑Transformers KVA ❑Motors HP FIRE ALARM SYSTEM (Requires 3 sets of plans): of Qty IAO volts/amps aoA ❑ REPAIRS/MISCELLANEOUS: ❑Replace Burnt/Damaged Meter Can ❑Safety Inspection ❑Panel Change ❑OH to UG ❑ether: Updated 10/17/18 Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Owner Name: -ATL A*+7c afAC �AQ0 J�FOOL C51,%-W LLC- Phone Number: 901' 241"834 Electrical Company:S�c���y � '"" +z�r+1.�'G1+-�� ��bE�� Office Phone: lo4-391-4931 Fax: Co.Address: 3139 W Ae- City: SA ClNs,yJsLlt State: r-L Zip: License Holder: \-O,W nm M. MiLLki State Certification/Registration#: Ef=—000 1122 \ Notarized Signature of License Holder Ws-'L The foregoing instrument was acknowledged before me this JT day of jg,rvN'j 20 L in the State of Florida, County of­bU4^L Carmen#6GISM Signature of Notary Public A- EvilftMwah31111.202 ersonally Known OR [ ) Pr u Identification aFw� eNd� Meson" Type of Identification: S� 1,1• s CITY OF qqRPT1 A C H 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 `10) INSPECTION PHONE LINE 247-5814 ELECTRICAL COMMERCIAL OR MULTIFAMILY DETAILS PER BLDG PLANS - MUST CALL BY 41PM FOR NEXT DAY INSPECTION: 247-5814 PERMIT INFORMATION: PERMIT NO: ELPP18-0019 Description: 800 amps/240 volts/third phase- new commercial service Estimated Value: 55000 Issue Date: 6/25/2018 Expiration Date: 12/22/2018 PROPERTY ADDRESS: Address: 461 ATLANTIC BLVD RE Number: 170691 0010 PROPERTY OWNER: Name: ATLANTIC BEACH YARD REAL ESTATE LLC Address: 1238 BEACH AVE ATLANTIC BEACH, FL 32233 GENERAL CONTRACTOR INFORMATION: Name: Address: Phone: Name: CORTES ELECTRIC JOSE ELECTRIC Address: 3233 Bridgecove CIR JACKSONVILLE, FL 32216 Phone: PERMIT INFORMATION: Please see attached conditions of approval. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE.,: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. _ K A notice of Commencement is only required for work exceeding an estimated value of $2,500. For HVAC work, a Notice of Commencement is only required when HVAC work exceeds and estimated value of$7,500. .-O—Virf. City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road ER�r l 9 J �� z� j s' Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 �!FQA gr E-mail: building-dept@coab.us Date routed: I Z t City web-site: http://www.coab.us III APPLICATION REVIEW AND TRACKING FORM Property AddressA G ( R+(cL,4,0 epartment review required Yes No �-' uildin Applicant: �ClU1`C l r 'Planning &Zoning _ II --Tree Administrator Project: (� IQ~ N Public Works Public Utilities S C� a C Se—CL) c� Public Safety ' J � u r- °fir CO ervices Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: []Approved. [Denied. ❑Not applicable (Circle one.) Comments: BUILDING PLANNING &ZONING 'f 7—k Reviewed by: W Date: TREE ADMIN. Second Review: A roved as revised. Denied. �,pp ❑ []Not applicable PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. []Denied. ❑Not applicable Comments: Reviewed by: Date: Revised 05/19/2017 View Notes ERES19-00 9 -- -- Type (Asc) REVIEWS Jennifer Johnston F' E approved via email by Miguel DiP$erri. JFRD_ BATTERY CALCULATION WERE PESU BIN11TED AND APPROVED. EMAIL APPROVAL FORM TO SIGN OFF M IC U EL Di PIERRI F re Safety Inspector / CDN Reviewer J FPD PREVENTION OFFICE 51.5 N. Julia St., Jacksonville, Flcrida 32202 Office. 904-255-8561 cell- 904-763-1290 - Email_ DIPIERRI@bCOJ.NET 2-/4/2019 4.49.49 PM E Printing :: CR493282 Page 1 of 1 Duval County,City Of Jacksonville Jim Overton ,Tax Collector 231 E.Forsyth Street Jacksonville,FL 32202 General Collection Receipt Account No:CR493282 Date: 1/28/2019 User:Wertz,Mark Email:MWertz@coj.net FIRE MARSHALL FEE FOR SERVICES PROVIDED Name:City of Atlantic Beach Address:800 Seminole Road,.Altlantic Beach FL 32233 Description:Plans Review for"ERES 19-0029"ABBQ 461 Atlantic Blvd.Atlantic Beach,FL 32233 TranCode IodexCode SubOb ect GLAcct SubsidNo UserCode Project Pro ectDd Grant GrantDtl DocNo Amount 701 FRFP159FI 34222 ( I ( ( 150.00 Total Due:$150.00 Jim Overton ,Tax Collector General Collections Receipt City of Jacksonville,Duval County Account No:CR493282 Date: 1/28/2019 FIRE MARSHALL FEE FOR SERVICES PROVIDED Name:City of Atlantic Beach Address:800 Seminole Road,Altlantic Beach FL 32233 Description:Plans Review for"EKES 19-0029"ABBQ 461 Atlantic Blvd.Atlantic Beach,FL 32233 Total Due:5150.00 http://fmanceweb.coj.net/TCCR/printing.aspx?cr=CR493282 1/28/2019 i t Fire Plans Review Fire Prevention Division 214 N. Hogan Street, Room 281 Jacksonville, Florida 32202 Corrections CONTRACTOR: SED JOB SITE: ABBQ PERMIT#: Atlantic Beach — Not issued Please correct or provide the proceeding requested information to obtain plans approval. When resubmitting corrected sheets, please provide a written narrative letter responding to our comments and directing the plans reviewer to the sheets the changes have taken place. FAILURE TO SUPPLY RESPONSE LETTER "WILL" RESULT IN A RETURNED FOR CORRECTION PERMIT STATUS. Revised sheets should be clouded clearly showing areas were changes or corrections have occurred and re-inserted with the original set of drawings. Old sheet SHALL be removed. Unbound plans will not be reviewed. If this is an electronic submission, please make sure that the written narrative is submitted under corresponding along with a "complete set" (not just revised sheet) of electronic documents. 1/28/19 Fire Inspector Mark Wertz—904.255.8557—mwertz@coj.net 1. Battery calculations incomplete and/or incorrect. Monitor modules for tamper and flow? What are three non- fail safe relays being used to control? Seven horn/strobes ? Zero WP outdoor horn strobes? SECURITY ENGINEERING AND DESIGNS, INC 3139 WALLER STREET JACKSONVILLE,FL 32254 EF-0001122 FIRE ALARM SUBMITTAL FOR ABBQ 461 ATLANTIC BLVD ATLANTIC BEACH, FL INSTALL FIRE ALARM SYSTEM 0 opo y P Small Building Fire Alar Solutions K'I'd d e Technology that saves lives Intelligent Fire Alarms stems FM Us 1 , VS4 FDNY COA 6229 7165-1657: 0244 V� O 53000 Overview Features Kidde brand intelligent life safety systems offer the power of high- • Auto-programming speeds installation time end intelligent processing in configurations that deliver uncompli- e Supports V Series intelligent modules and detectors cated solutions for small to mid-sized applications.With intelligent detection,electronic addressing,automatic device mapping, • Form C contacts for alarm and trouble,Form A for supervisory optional Ethernet®connectivity,and a full line of easily-configured . Electronic addressing with automatic device mapping option cards and modules,these flexible systems offer versatility . Optional Ethernet port for diagnostics,programming and a that benefits building owners and contractors alike. variety of system reports The VS1 provides one Class A or Class B intelligent device loop • Two programmable switches with LEDs and custom labeling that supports up to 64 device addresses,and two Class B Notifi- cation Appliance Circuits(NACs).Optional Class A device wiring is • Supports Genesis horn silence over two wires,and UL available with the use of a module. 1971-compliant strobe synchronization The VS4 provides one Class A or Class B intelligent device • Supports GSA-REL releasing module for fire suppression loop that supports up to 250 device addresses.Loop controller • Class B or Class A wiring modules may be added in combination to expand total system • Ground fault detection by module capacity in 250-point increments to up to 1,000 device addresses. Supports up to eight serial annunciators,(LCD, LED only, and VS4 panels include four NACs that may be wired for either Class A • or Class B operation. graphic interface) The RZ116-2 module adds even more capacity to VS installations • Can use existing wiring for most retrofit applications by adding up to 16 conventional device circuits and two additional • Upload/download remotely or locally notification appliance circuits.This makes them ideal retrofit solu- . Two-level maintenance alert reporting tions that can accommodate new intelligent detectors,as well as • Pre-alarm and alarm verification by point existing conventional devices. VS Series supports a wide range of high-end features, including: • Adjustable detector sensitivity • Intelligent modules,detectors,and bases • 4 x 20 character backlit LCD display • GSA-REL Releasing Modules • Optional earthquake hardening:seismic Importance Factor 1.5 • R-Series remote annunciators • Standalone operation • Integrated Carbon Monoxide gas sensing with V-PCOS de- • Transmission test frequency by hour tectors including distinct audible signaling . Alarm ON command manually activates alarm condition Page,of t_ ;_, V85005-0135 N i,r ;,I•: €z>r 01 Issue 1.3 Application Kidde VS Series life safety systems are powerful intelligent solutions of strobes to UL 1971 standards.For Genesis devices,enabling for small to mid-sized buildings.Advanced intelligent technology this feature allows horns to be silenced while strobes on the same delivers the benefits of flexible system installation,while clean and two-wire circuit continue to flash until the panel is reset. easy-to-operate user interfaces make panel operation and system maintenance quick and intuitive. Flexibility built right in Two fully-programmable front panel switch/LED combinations provide The smart choice an added measure of flexibility.Their slide-in labels take the mystery Electronic addressing eliminates the tedium of setting dipswitches, out of custom applications,and present a dean finished appearance. and automatic device mapping ensures that each device resides on the system at its correct location.Meanwhile,innovative pro- Perfect for retrofits gramming allows the designer to customize the system to pre- Kidde VS Series control panels are particularly well-suited to cisely suit the needs of the building owner. retrofit applications.All connections are made over standard wiring -no shielded cable required.This means that in most situations Reliability you can count on existing wiring can be used to upgrade a legacy control panel The inherent fault-tolerant characteristics of Analog/Address- to VS technology without the expense or disruption of rewiring able Technology boosts the reliability of Kidde fire alarm systems. the entire building.VS control panels also support the ingenious When combined with VS Series smoke and heat detectors,these RZI16-2 zone module,which adds up to 16 conventional circuits systems deliver a level of dependability not previously available and two NACs.This combination easily accommodates new intel- for small to mid-sized applications.All Kidde systems are built to ligent detection alongside existing conventional circuits,making it exacting reliability benchmarks and meet international standards an superior solution in the retrofit market. for quality,in addition to agency listings for dependability. Scalable IP and Cellular Communications Clear-cut remote annunciation Several popular third-parry IP/Cellular communicators have been Remote annunciation is a strong suit of the VS Series fire alarm tested with the VS control panels and are compatibility listed to systems.Up to eight annunciators can be installed on a single UL864.The IP/Cellular communicators meet NFPA72 2013 edition system.Compatible annunciators include a range of LED and LCD requirements for sole or secondary transmission paths.Using IP/ models that provide zone or point annunciation,as well as com- Cellular communicators can reduce the cost of ownership by mon control capabilities.VS control panels also supports graphic eliminating POTS lines. Please see the VS control panel compat- annunciation with optional graphic annunciator interface modules. ibility documentation part number 3102354-EN for a full list of Each interface provides common control and 32 LEDs. compatible communicators. Signals with a difference A complete line of accessories VS Series NACs are configurable to fully support the advanced VS Series life safety systems are supported by a complete line of signaling technology of Kidde Genesis and Enhanced Integrity no- analog/addressable detectors,modules and related equipment. tification appliances.These devices offer precision synchronization Consult the Ordering Information section for details. Programming and remote diagnostics Dimensions Kidde VS Series life safety systems are simple to set up,yet offer (1) (2) (3) (4) advanced programming features that put these small building w-.( panels into a class of their own.The auto programming feature O O O 'O quickly gets the panel operational using factory default settings. I" i �� O I. Basic zone and point settings can be programmed through the O O 10 front panel interface,so the system is up and running in no time. ) O O O For more advanced system configuration and correlation groups 01 a) ' programming,VS Series systems interface to a PC running com- O_ •0 [0 patible VS-CU software.This option offers full system configura- tion in the familiar Windows®operating environment.Connection is made to a laptop through the panel's optional RS-232 communi- cations port,which can also be used to connect a system printer. Among the many innovative features of VS Series control panels �°� N* is the optional network card.This module provides a standard (1)Surface Mounting Holes (3)Backbox with Door Attached 10/100 Base T Ethernet®network connection that permits access (2)Semi-flush mounting Holes (4)Backbox with door and trim kit attached. to the control panel from any remote location with the correct communications protocols.The connection can be used to down- Panel dimensions,in(cm) load to the panel from the VS-CU,or upload and view system Muael 01• oz 03 04 051 oe 07 , D8 l D9 28.0 3.85 9.0 22.0 15.75 10.25 4.9 ( 30.1 2.7 reports using the VS-CU. vsa i (71.1) (9.8) (22.8) (55.8) (40.0) (28.0) (12.4) (76.4) (6.8) Available system reports include:Correlation groups,Device de- vs1 5215 46 -a.85 7.s 15.5 14.25 1o.2s ; 4.9 23.6 i 2.i tails, Device maintenance, History,Internal status,System configu- (54.6) (9.8) (19.0) { (39.4) (36.2) (26.0) (12.4) (59.9) , (6.8) ration, System status,Walk test, Dialer,and CO runtime. •Add 1-1/2 in.(3.81 cm)to Dl and D5 dimensions for trim kit.The trim kit provides 0.75 inches(1.9 cm)of trim to the top,bottom,and sides of the backbox. Page 2 of 8 D A A s l_,E E i V85005-0135 4 V No: to be, owed`:ar'srsiai!afion purposes. Issue 1.3 System Layout VS4 Any combination of two single-or dual device loop modules ---------------------------------------------------------------------- Standard Loop:250 points(one expansion slot) V-SLC2-2 Expander,Loop 1 of 2:250 points Up to 125 sensors and 125 modules per loop -- — .._._...--------- .__ ... — —.._. _. (one expansion slot) V-SLC2-1 Expander Loop:2.50 points(one expansion slot, V-SLC2-2 Expander,Loop 2 of 2:250 points Up to 20,000 feet of wiring per loop Four Class Q or two optional Class A NACs Four Glass 6 or two optional Class A NACs Optional 10 A or 6.5 A Booster II' Ethernet(SA-ETH) DACT/Dialer(SA-DACT) Up to eight remote annunciators RS-232(SA-232) Sixteen Conventional IDCs, Relays:Two Form C,one Form A two additional NACs with RZI16-2 module Each VS4 panel has room for up to two device loop controller modules in any combination of single or PanelLayout dual 250-device loops.VS4 comes with one loop that supports up to 125 detectors and 125 modules. , . ......nn... .......... nn VS1 2 go �+ 7 - 8 DD O T Loop supports up to 64 intelligent devices of any type. — 8 T 10 Up to 20,000 feet of wiring. n D r i ............ ....__.. 12 IBM REM I ® e IJ lro Glass B yr two optional Class A NACs 'qqWOptional 10 A or 6.5 A Booster Power Supply o 1 Transformer 2 Main AC wiring block&fuse holder 3 RS-232 card connector(J3) Ethernet(SA-ETH) 4 Dialer card connection(J8) DACT/Dialer(SA-DACT) --� 5 Ethernet card connector(J1) 6 Main circuit board RS-232(SA-232) 7 Panel backbox enclosure Relays:Two Form C,one Form A 8 Operator interface 9 SLC card connector(J7) 10 Class A card connector(J2) Each VS1 panel ships with one device loop controller that sup- 11 Tie wrap mounts ports 64 devices of any type.This panel's device capacity cannot 12 LED expander connector(J6) 13 Standby batteries be expanded. Page 3 of a V85005-0135 Issue 1.3 Wiring & Configuration Device loop Auxiliary&smoke power outputs(TB3) The system provides one device loop circuit with a total capacity The control panel provides two auxiliary power TB3 of 125 detectors and 125 module addresses.The loop circuit is outputs that can be used for powering ancillary (2)---3-No supervised for opens,shorts,and grounds. equipment such as remote annunciators and two wire smoke detectors. Aux 2 can be software (1) 01 NC circuit VS4 VS1 selected to operate continuously.The circuit is 0 specifications supervised supervised for shorts and grounds. Device loops _ One Class B or A One Class B or A loop, loop,supporting 125 supporting 64 devices of Circuit specifications (2) NO 0 detectors and 125 any kind. Circuit voltage 21.9 to 28.3 V modules.Expandable to range (2) NC fourloops. ....................._...._.._..._............................................_...._...................... ---- -- -- ----- - - Resettable circuit 24 VDC nominal at 500 mA (3) Commm unicaatiotion Maximum 2 20 0 V peak-to-peak NO (Aux power 2) line voltage - Continuous circuit 24 VDC nominal at 500 mA. 0 Circuit current 0.5 A max (Aux power 1) Use this circuit for powering Circuit 660 total,0.5 uF,max two-wire smoke detectors. O impedance -- '--"-"""" - ------ -''------ Note:Any current above 0.5 amp connected to both Aux (4) Isolators 64 maximum I and 2 will reduce the total available NAC power by that Signal Supported on a system-wide basis(all device loops) amount. Synchronization when using an addressable notification appliance (1)Trouble circuit(NAC)module and Genesis or Enhanced Integritynotification appliances. ............................_...................................................................................................._......._._...................................... (2)Supervisory Alarm,trouble,and supervisory relay(TB3) (3)Alarm Closs 8w mg Class Awinng The trouble relay is normally-open,held closed, and opens on any trouble event or when the (4)Smoke/Aux SLC A ,m nHAunp SLC A ;o panel is de-energized.The supervisory relay is SLC e -m + SLC B ; normally-open,and closes on any supervisory m m event.The alarm relay changes over on any Lapp Loop Loop Loop Loop wrd device d.W. Loop urd Daly Lina device AaVles alarm event. Relay specifications ..........................._..........__ __...__----._...................._-- ._.._.. Alarm Trouble Supervisory Notification appliance circuits(TB2) Type Form C Form A _ _. ..... ......... —..- --._............... VS4 control panels come equipped with four notification appliance Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive circuits.VS1 control panels come with two NACs.Each circuit can Relay circuits can only be connected to power-limited sources. be individually configured for continuous,temporal,synchronized, and coded output. . ....... ....... .......... ...... .. .................. ..... Specifications i VS4 V51 _.._.._..._._..........__ ..... _...._.. ._._._. Annunciator loop(TB4) Circuit Type 4 Class B or 2 Class AI 2 Class B or 2 Class A The control panel provides a connection for up to eight serially with SA-CLA module driven and supervised remote annunciators. Voltage 24 VFWR Current 6.0 A total,2.5 A max. 3.75 A total,2.5 A max. Circuit specifications per circuit at 120/230 per circuit at 120/230 Device loops Class B(Style 1)or Class A(Style Z) VAC 60 Hz. VAC 60 Hz. Circuit voltage 2.55 V 5.0 A total,2.5 A max. 3.0 A total,2.5 A max. _frim-—9--....................._ _._......_..._.._...._.__... --.................. ........_..._._.__............._.................................. • Circuit current 30 mA max _ per circuit at 230 VAC per circuit at 230 VAC Circuit Up to 8 annunciators or 4000 feet 50 Hz. 50 Hz. impedance Impedance 26 O total,0.35 pF max EOLR 15 K O,t/2 W Class B Class A Synchronization Supported system-wide ........................._...._...._....._........_....:........................._..........._...._....--------...._._.......-------..__..__._._.._..._......---....._......._...._........ Channell Channell Channel l Channell Ck-9 Wring ❑—A vnring TB4 TB4 NACt- + + � NAC7- + 0 ,Uc„ NAci+ Annunciator Annunciator NAC2- + + EOLR NAC2- + + CH1(+)IN CHI(+)IN NAC2• - - � NAC2+ CHI(-)IN CHI(-)IN 782 2 0 NAc3- � - �CH2(+)IN CH2(+)IN rota, NOLs + (9 CH2(-)IN CH2(-)IN NAG- + + NACI 0+ Tea Marking indicates output signal polarity when the circuit is active.Polarity reverses when the circuit is not active.Wire notification appliances accordingly.Notification appliance polarity shown in active state. 0 Paye 4 of 8 V85005-0135 Issue 1.3 Option Cards Kidde VS Series panels are supported by a complete line of mod- RZI16-2 Remote Zone Interface Module ules and related equipment that enhance performance and extend system capabilities.Option cards plug directly into the control 7_ k panel main circuit board or are connected to it with a ribbon cable.After installation,terminals remain accessible.The cabinet pro-vides ample room for wire routing,keeping wiring neat at all times. - �"-mi ..............................................._......................................._._..._.._._......................_..._........_.._................................................................................................ Single and Dual Loop Controller Cards The RZI16-2 Addressable Remote Zone Interface Module is an The V-SL02-1 is a single loop controller card that can be used addressable device that provides connections for sixteen Class B with the VS1 as a replacement for the standard 64-point loop,or Initiating Device Circuits and two Class B Supervised Output with the VS4 as a 250-point expansion module. Circuits.The inputs and outputs can be configured individually for The V-SLC2-2 is a 500-point dual loop controller card for the VS4 several device types. that provides two IDC circuits,each with 125 detector addresses The RZI16-2 requires 18 consecutive addresses on the Signaling and 125 module addresses. Line Circuit(SLC).Addresses are assigned electronically.There are no address switches to set. Specifications V-SLC2-1 V-SLC2-2 Device Addresses VS4:one loop,250 VS4:two loops 500 The RZI16-2 incorporates two 8-segment DIP switches that are device addresses device addresses used to select the Alarm or Supervisory default device type for VS1:64 addresses each of the 16 IDC circuits.The module also includes one 4-seg- Wiring Class B or Class A ment DIP switch used to select the default Relay or NAC output Operating Voltage 24 VDC device type.Device types other than the default are accomplished _. ......................_._. _.....__...._._�_� _...--..—__-. -.--......__ through programming. Operating Current Standby:55 mA Standby:45 mA 9 p 9 g• (fully loaded loop) Alarm:80 mA Alarm:70 mA - RZ116-2 Specifications Note.These ratings do not include the use of two-wire smoke modules. Communication Line Max.20.6 Vpeak-to-peak Voltage 24V/Aux nominal: 24 VDC Voltage Terminal Rating 12 to 18 AWG(0.75 to 2.5 mmg Supervisory current: 250 mA at 24 VDC nominalAlarm current: 1000 mA Circuit Current 0.5 A max. 24V/Aux minimum: 18.4 VDC Max total loop 66 C 24V/Aux maximum: 26.4 VDC resistance NAC1,NAC2 nominal: 24 VDC Max total loop 0.5 pF Current capacitance Standby current Isolators 64 isolators maximum per loop(total both for 4.7 k EOL(U.S.) 4.8 mA/circuit isolator bases and modules) Standby current for Ground Fault 0 to 5 kft 3.9 k EOL(Canada) 5.7 mA/circuit Impedance Alarm current Operating 32 to 120°F(0 to 49°C) at nominal voltage 31.1 mA/circuit ...................._ ...•.....—............_.....----- ....._._ ....._..............__... Environment 0 to 93%noncondensing at 90°F(32°C) Relay outputs Quantity 2 Type Rating(pilot duty) Programmable 24 VDC at 2.5 A ---____.-._—...... Input circuit wiring 25.0 per wire SA-ETH Ethernet Interface Card resistance _ SA-ETH wiring The SA-ETH card provides a Initiating device circuits ro network Network cable-jstandard 10/100 Base T Ether- Quantity 16 Network cable-j==9 net network connection for EOL resistor 4.7 kR(U.S.);3.9 kO Canada connecting to an intranet,a local Zone voltage 22.78 V for 4.7 kO(U.S.) network,or the Internet.The 22.08 V for 3.9 kft(Canada) cardcan be used to download Alarm current 31.1 mA/channel at nominal voltage wAlarm impedance range <680 0 E0 configuration programming from Trouble impedance range >5.55 kft ° the VS-CU to the panel. Supervised output circuits The Ethernet card is installed on EOL resistor 15 1<0 ® Quantity 2 the plastic assembly and con- o Short Circuit detection <2.6 kn Ethernet card nects to the main Circuit board Open circuit detection >61.9 kO via a ribbon cable. Contact ratings 24VDC at 2.5 A(5 A for two NACs) ___..__.........__.........._......_.... _._—..._.._._._.........----.._.__._................ ................. . SA-ETH specifications Compatible cabinets...--.._..._.__............._..MFC(A),VS4,APS — ----._......._._ _.—__........ --.�--- Ethernet 10/100 Base T Operating environment Temperature 32 to 120`F(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90°F (32°C) Page 6 of s V85005-0135 Issue 1.3 ..... _.......- ... SA-DACT Dialer SA-232 RS-232 interface The SA-DACT provides communications between the control The SA-232 card provides an RS-232 in- SA-232 wiring panel and the central station over a telephone line system,It terface with VS panels.It can be used for GND(black wire) TXD(white wire) transmits system status changes(events)to a compatible digital connecting a printer to the control panel RXD(red wire) alarm communicator receiver over the public switched telephone to print system events.The card also F F F network.The dialer is capable of single,dual,or split reporting can be used for connecting a computer ®® of events to two different account and telephone numbers.The to download a configuration program O modem feature of the SA-DACT can also be used for uploading from the VS-CU to the control panel. and downloading panel configuration,history,and current status The RS-232 card is installed on the plas- to a PC running the VS-CU. tic assembly and connects to the main circuit board via a ribbon SA-PACT Phone line 2 cable. wiring To wall Phone line 1 phone Jack SA-232 specifications Phone cables ,Operingvoltage Standard EIA-232 at _ (supplied) RJ37 jacks ...............................................................__..._..------.._...._._.—........................--......_...._.... Terminal rating 12 to18 AWG(0.75 to 2.5 sq mm) The dialer phone lines connect to Operating environment connectors on the dialer's main Temperature 32 to 120°F(0 to 49°C) ® circuit board.Phone line 1 connects Humidity 0 to 93%RH,noncondensing at 90°F(32°C) --- --- to connector J4 and phone line 2 . co - connects to connector J1. _.. _...-._.-___..__ _....___..______........__. _ __ _._ ._._._.__..._..... CL SA-CLA Class A Module(VS1 only) '00(30c] :_ Q The SA-CLA card provides Class A capability for NAC wiring. oo❑❑❑�e' °[r° Its terminal block provides the wiring connection for NAC return g; ❑o wiring.The card is required for annunciator Class A wiring even ❑ though this wiring does not return to the SA-CLA card.The SA- The SA-DACT queues mes- CLA is compatible with VS1 control panels only.VS4 panels are sages and transmits them based on priority(alarm,supervisory, Class A Ready.The SA-CLA is installed directly to the control trouble,and monitor).Activations are transmitted before restora- panel circuit board using its plastic standoffs and plug connection. tions. SA-CLA specifications The SA-DACT is installed on the plastic assembly and connects to Operating voltage 24 the main circuit board via a ribbon cable. ..........................-.........-.................................................._-....._._..............................................I............ Operating current 3.75 A FWR total at 120/230 VAC 60 Hz SA-DACt specifications 3.0 A FWR total at 230 VAC 50 Hz _ 2.5 A max per circuit Phone line type One or two loop-start lines on a public, Circuit impedance 26 ohms,0.35uF switched network _.__....._.__.__......._ _._...._.__...............__ _....__ Phone line connector RJ-31/38X(C31/38X) Terminal rating 12 to18 AWG..... to 2.5 sqq mm) — formats Contact ID SIA DC-05 Operating environment Communication form _. ( _ ) Temperature 32 to 120°F(0 to 49°C) Operating environment Humidity 0 to 93%RH,noncondensing at 90°F Temperature 32 to 120°F(0 to 49°C) (32°C) Humidity 0 to 93%RH,noncondensing at 90°F (32°C) ..... _..........._..—................_.._ .................. ......................... ..... Compatible DACRs D16L-VS LED Display Expander(VS4 only) Receiver Models Formats The D1 6L-VS LED Display Expanders provide LED annuncia- Ademco 685 Contact ID tion for up to 16 zones.It provides two LEDs for each zone.Two FBII CP220 Contact ID D16L-VS LED display expanders can be installed in each VS4 Osborne Hoffman OH 2000 Contact ID panel. -- _._....._.._..._..._.._........................................._........._._....._............................................................ .. Bosch D6600 Contact ID Silent Knight 9800 Contact ID (t -l- (3) (4) Sur-Gard SG-MLR1,MLR2 Contact ID (2) 177-71 gC� t C� Z��247 I Zone is 1=j giEm (1)LED 1 tb! (2)LED 2 (3)LED Expander 1 (4)LED Expander 2 (5)Alarm/non-alarm and trouble zone LEDs Y, Page 6 of 6 0)A I A S H V85005-0135 No; to be wa ed'.,)r ws.sZ Issue 1.3 Specifications VS1 VS4 Device loops 1 loop Class B or Class A(Styles 4,6,7)supporting up to 1 loop,expandable to 4,Class A or B(Styles 4,6,7), 64 device addresses(any combination of detectors and each loop supporting up to 250 device addresses(125 modules) detectors and 125 modules max.).Addresses 1 to 125 are Maximum T-taps:63 for detectors and addresses 126 to 250 are for modules (each device can be on its own branch) Maximum T-taps/loop: 124 ...._._______._.._....._...._ ._ _�—__......._............__._.....__...- ._...._..._.............._—..—..._...._—..... --- -...----.......................... Notification appliance 2 Class B(Style 1),Class A(Style 4 optional 4 Class B(Style Y)or 2 Class A(Style 2) circuits 3.75 A FWR total at 120/230 VAC 60 Hz 6.0 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 5.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max.per circuit 2.5 A FWR each max.per circuit Primary power 120 VAC,60 Hz, 1.3 A max. 120 VAC,60 Hz,2.0 A max. 230 VAC,50-60 Hz,0.62 A max. 230 VAC,50-60 Hz,0.97 A max, Base panel current standby 155 mA 172 mA — Base panel current alarm 204 mA 267 mA Input zones 16 max. 32 max. -- - - ...... .._._. —_.._...._............._________-....—.__...._.._.........._..----............................_... ._._ ........ ................--——.....__.........._._....._—__.�_......._.............-------._._... —...... Remote annunciator 8 drops max.,RS-485 Class B,Class A is optional 8 drops max.,RS-485 Class A or B Data line length:4,000 ft.(1,219 m) Data line length:4,000 ft.(1,219 m) ............... --- Operating voltage 24 VDC panel — Auxiliary power output Aux power 1:500 mA,24 VDC circuit Aux power 2:500 mA,24 VDC(1 A possible if you reduce total available NAC power by 500 mA) Output:28.3 to 21.9 VDC,special application Note:For a list of compatible devices,see the VS1 and VS4 Series Compatibility List(P/N 3102354-EN) Loop circuit Maximum loop resistance:66 fl Maximum loop capacitance:0.5 OF Communication line voltage:Maximum 20.6 V peak-to-peak Operating current(fully loaded loop)Stand by:55 mA/45 mA Alarm: 125 rrW115 mA(not including two-wire smoke modules) Circuit current:0.5 A max.Style 4,6,and 7 wiring Max.resistance between isolators:Limited only by overall wire run lengths 64 isolators maximum per loop(total both isolator bases and modules) Batteries Type:Sealed lead acid �— Voltage:24 VDC Charging current:2.47 A max.Amp hour capacity:26 Ah Standby operation:24 hour or 60 hour Placement:Up to two 10 Ah batteries will fit in the VS1 control panel cabinet and two 18 Ah batteries will fit in the VS4 control panel cabinet.If larger batteries are required,use a battery cabinet. _.._ -- ---...- —...... ___...__—.—....__..._..._.._..�__..__..__..._. _............. --........ ---...._._........... ..._.._.... ----._................................. SA-DACT dialer Phone line type:One or two loop-start lines on a public,switched network Phone line connector:RJ-31/38X(C31/38)g Communication formats:Contact ID(SIA DC-05) Operating current Standby/Alarm:41 mA Max.: 100 mA FCC registration number:GESAL01 BSADACT Industry Canada Registration number:3944A-SADACT Ringer equivalence number:0.1 B ..............._........_.. ..__.._.._.........................---.._._....................................---...__.......__....._.._...__.......----................— -----.._._............_......._....._.._._..—......................._.._...... Ground fault impedance 0 to 5 kf1 ------- Alarm contact Form C N.O.24 VDC at 1 A(resistive load) Trouble contact Form C 24 VDC at 1 A(resistive load) Supervisory contact Form A N.O.24 VDC at 1 A(resistive load) _ _._.__...—.._..._..................................._ _........................._..__............—..................................._.. —._......_........_.._-----..._..................-----. .—..._..........--._--_ ......_.................__.............._—._.................. Environmental Temperature:0 to 49°C(32 to 120°F)Relative humidity:0 to 93%noncondensing —_..... -- — __._.._... ..........................._ —_..........._._ Terminal rating Al terminals rated for 12 to 18 AWG(0.75 to 2.5 mm9 Page 7 of 8 U)A t A S H; V85005-0135 Issue 1.3 Ordering Information M'v Kidde Part Description VS4 Fire AlarmS stems VS4-G Four loop system with one 250 point loop installed.110v,gray door. Technology that saves lives VS4-G-2 Four loop system with one 250-point loop installed.230v gray door. VS4-G-2-PG Four loop.system with one 250-point IooP.installed.230v,gray em door,Portuguese. Contact us... VS4-G-2-SP Four loop systwith one 250-point loop installed.230y,gray door,Spanish, _ VS4-GC Four loop system,one 250-point loop installed. 110v,gray door,LED strips,Canada. Email:kidde.fire�is.utc.com VS4-GD Four loop system,one 250-point loo installed.110v,gray door,with dialer. Web: Kidde.comlEngtneeredSystems -.p.--- g y ---- - VS4-GF Four loop system,one 250 point loop. 11 Ov,gray-door,LED strips,French Canada. VS4-G PG Four loop system with one 250-point loop installed.110v,gray door,Portuguese. Kidde is a UTC brand. VS4-G-SP Four loop system with one 250-point loop installed.110v,gray door,Spanish. 1016 Corporate Park Drive VS4-R Four loop system ........ 250-pointP —�_---- VS4-R-2 Four loop system with one 250-point loop installed.230v,red door. ®2017 United Technologies Corporation. VS4-RD Four loop system,one 250-point loop installed. 110v,red door,with dialer. All rights reserved. SA-TRIM2 VS4 Flush mount trim,black. VS1 Fire Alarm Systems................................................................ - -....__................................... _�.................... .. . . . . ................ ---.-........—...__......_..----............... VS1-G One loop system with one 64 Int loopinstalled.110v,gray door. VS1-G-2 One loop system with one 64-point loop installed.230v,gray door. VS1-G-2-PG One loop system with one 64-point loop installed.230v,gray door,Portuguese_._ VS1-G-2-S0 One loop system with one 64-point loop installpd_230v,gray door,Spanish. VS1-GD One loop system,one 64-point loop installed. 110v,gray door,with dialer. VS1-GL One loop system,one 64-point loop installed. 110v,gray door,English Canada. _ VS1-GL-F One loop system one 64 point loop installed 110v gray door,French Canada VS1-G-PG One loop system with one 64-point loop installed. 110v,gray door,Portuguese. VS1-G-SP One loop system with one 64-point loop installed.110v,gray door,Spanish. VS1-R One loop system with one 64-point loop installed.-110v�red door. _._._.........._.................................. VSi Fi 2 One loop system with one 64-point loop installed.230v,red door. VS1-RD One loos one 64-point loop installed. 110v,red door,with dialer. SA-TRIM1 VS1 Flush mount trim,black Option Cards V-SLC2-1 Expansion module,ons,250-device loop For VS4 only. V-SLC2-2 Expansion module,two 250-device loops,500 devices total.For VS4 only. — RZI16-2 Remote Zone Interface Module. 16 Gass B IDCs,2 Class B Output.Bracket included. SA-DACT Dual Line Dialer/Modem,supports Contact ID,mounts in cabinet on base plate. SA-232 RS-232 Serial Port for connection torp inters&computers,mounts in cabinet.__ SA-ETH Ethernet Port,Slave,mounts in cabinet on base plate. SA-CLA Class A adapter module.Provides Class A capacity on NACs.Mounts in cabinet on main board.VS1 systems_only. _ D16L-VS LED Annunciator module, 16 X 2-LED zones(4 programmable for sup). Mounts in cabinet to right of LCD display.For VS4 only. D8RY-VS Canada only.LED Annunciator module,two LEDs per zone,16 zones(4 alarm only, .__.._....................._...._....._.....8_supervisory only,4 alarm or su�ervisory�._Mounts in cabinet._For VS4 only. ......... Accessories CTM City Tie Module.2-gang.Connection to a local energy fire alarm box. MFC-A Multifunction Fire Cabinet,8"x 14'x 3.5'-red. —._..........._.._...................._...__...--......................- -----.._............._..--- -....._................................................................................................__................................................. BC-1 Battery Cabinet.14.0"x 18.25"x 7.25".Holds two 12V24A batteries. ---.....-- ---------------- BC-1 R Battery Cabinet-Red.14.0"x 18.25'x 7.25".Holds two 12V24A batteries. GSA-REL Releasing Module ------------_............._.._...__._---- -- BC-1 EQ Seismic hardening Kit for VS Series panels.Includes battery hardening for BC-1 enclosure and components to harden panel internal components. Programming Tools VS-CuVS Series configuration and diagnostics utility. --._... —._...._._— _.. ................ 260097 RS232 cable,4 conductor,DB9 PC interface .........._..........._.....-----.......I.._............__..—_.._..........._................................................................................................................................................................ Page 6 of a 3 A V85005-0135 Issue 1.3 \ Arunlnciatiein Kidde Technology that saves lives R- Series Remote Annunciators RLCD, RLCD-C, BLED, RLED-C, ►, g RLED24, GCI O FDNY 7120-1657: COA 6020 0254 53424 Overview Features Kidde R-Series Annunciators are high-performance remote an- • LCD models feature large 4 x 20 character backlit LCD display nunciators that provide status indication and common controls for . LED models provide 16 pairs of LEDs for zone annunciation compatible fire alarm control panels.This family of annunciators offers LCD or LED annunciation. Models are available with and • Available expander extends capability with 24 pairs of LEDs without common controls. . Up to two expanders may be wired to each annunciator There are three R-Series annunciator models, plus an LED-based . Status LEDs and internal buzzer standard on all models expander. Up to two expanders can be connected to any annun- ciator.The expander includes 24 pairs of LEDs that extend the • Common controls available for LED and LCD display models capabilities of any of the annunciators. • Available keyswitch for disabling common controls All annunciator models include status LEDs and an internal buzzer. . Standard 4-inch square electrical box mounting Two models have an LCD text display, and one has 16 pairs of LEDs for zone annunciation. LCD models feature a large back-lit, Class B or Class A RS485 wiring standard four by twenty character per line, super-twist liquid crystal display. • One-,two-, and three-position enclosures available R-Series annunciators and expanders are mounted on a standard • Graphic Annunciator interface, includes common control, indi- 4-inch square electrical box, using the included mounting ring. cators and 32 LEDS They can also be surface mounted in locking steel enclosures. . No programing required, set the address and unit receives all Three different enclosures are available. information from panel A keyswitch and graphic annunciator interface is available for R-Series annunciator applications.The keyswitch enables or dis- ables common controls.The graphic annunciator interface cards supports 32 LEDs and 16 switches on the graphic panel display. Page 1 of 4 U A s H w E I K85005-0128 Not to be usea for instalIssue 1 Application Annunciator Wiring R-Series annunciators communicate with the FACP on the RS-485 ,annunciator, Class A data riser.This can be configured for Class A or Class B commu- nication.Annunciators do not provide ground fault isolation. FACP Annunciator Annunciate Rr�� CH (+)IN CHI(+)IN These annunciators are stand-alone units that can be powered by CHI• -:(-)IN CHI(-)IN the FRCP or by an approved power supply. CHI- CHI c+)OUT 0 CHI(+)OUT CH2+ CHI(-)OF 0 CHI(-)OUT CH2- CH2(+j IN CH2(+)IN CH2(-)IN CH2(-)IN 81 flo LISTED 24 VDC CH2(+)OUT 0 CH2(a)OUT o suPPLv CH2(-)OUT 0 CH2(-)OUT ✓ �� 24 VDC+ 24V(+)IN 24VIN ®®® °' 21 VDC- 21V(-)IN 21VIN g24V(+)OUT 0 24V(+)OUT o 24V(-)OUT 0 24V(-)OUT GROUNDLIM OROUND g RLCO-C RLED-C Annunciator,Class B s s °e FACP Annunciator Annunciator ✓ "°""'- p°po °°oo RS-485 CH7(+)IN CHI(*)IN ®®® Q ° CHI CHI(-)IN -OC (_)IN °o -Ff:: CHI- CHI(+)OUT 0 CH1(+)OUT CHI(-)OUT 0 CHI(-)OUT 0CH2(+)IN 0 CM2(+)IN 0 CH2(-)IN 0 CH2(-)IN RLCO RLE024 LISTED 24 VDC 0 CH2(y OUT 0 CH2 OUT Features by model RLCD RLCD-C RLED-C RLED24 SUPPLY 0CH2(_jOUT 0CH2(-)OUT —_. _......_.......___..._ ...._.___...._..__..__..............._.._....._ 24 VDC+ 24V(+)IN 24V(+)IN Reset _..._........................_ ......_... ✓ ✓ -kFf ..........................._.__.._......_. ... _....................................._......................................._.__ __....... 24 VDC- 24V(-)IN 24V(-)IN ACI. SIIenCe ✓ ✓ ✓ - 24V(+)OUT 0 24V(+)our Fire Alarm ✓ ✓ ✓ - 24V(-)OUT 02 4V(-)OUT Supervisory ✓ ✓ ✓ GROUND GROUND Ground Fault ✓ ✓ ✓ Trouble ✓ ✓ ✓ ...................................._._..._..._...._........_.__.._............_.__...__ __............................_ _ ----...............__._--- Controls Enabled ✓ ✓ ✓ AcWSilence - ✓ ✓ ✓ Expander Reset ✓ ✓ --------- .... ..........._.... .........................................................................................._......-......_-._.................................. .. ...................................................................���������� Annunciator First Ex pan er on xDerWm Signal Silence ✓ ✓ OUT IN our IN our Drill ✓ ✓ - ' Lamp Test V(-)0-----0V(-) V(-)@ . 0 v(-) v(-)0 ✓ ✓ ✓ v(+) v(*) VN(D- - ------ 3 v M v(+)0 ' ..........------..-..........................---------._............................__.._..._._..-_..._.._......._.....---._..._...._.__........_._........ LCD Display ✓ ✓ F F F@ :_.OF Fe Zone Active LEDs 16' 24" E E E@ - -------.- 0E Ee D D D@ _ __-_-__�_ 0 D D 0 Zone Trouble LEDs 16 24 ; "zones 13-16 may be selected as Supervisory on FX-64 and VS1 e e e @ - ------- 0 e e 0 ' zones 13-16 and 29-32 may be selected as Supervisory on FX-1(X)0 and VS4 L=A A(2) Graphic Annunciator Interface The GCI Graphic Annunciator Driver is an interface card that Remote Ke switch connects the fire alarm control panel to the display panel of an Key switch graphic annunciator. Annunciate I I LSRA-RK The annunciator card supports 32 LEDs and 16 switches on the KEYSWITCH(_) TeI-I KEYSWITCH(+) Te1.2 graphic panel display.It includes status LEDs and an internal buzzer. The graphic interface is supplied with snap track mounting.It is Keyswitch Specifications attached to a plastic mounting rail that requires two EIA panels. Maximum 5 Vdc voltage - The annunciator communicates with the FACP on the RS-485 —" - Maximum 200 mA data riser.This can be configured for Class A or Class B commu- current nication.The annunciator does not provide ground fault isolation. Mounting 2-1/2 in(64 mm) It is a stand-alone unit that can be powered by the FACP or by an _ _ deep 1-gang box— - N40, approved power supply. Termination Screw terminals Maximum 12 AWG Graphic Annunciator Interface Specifications --- wire size (2.5 mm sq) Alarm current 146 mA at 24 Vdc(with 36 LEDs ON) Contact Normally open ......_.__.._............. Standby current 36 mA at 24 V d c with no LEDs ON) configuration Maximum current 10 mA per LED Page 2 of 4 DATA SHEE K85005-0128 Not to be used for inst1llwion =; Issue t Annunciator Connections Annunciator Mounting Annunciator ANNUNCIATOR RS-485 RISER -+ Mounting slot ® •- DIP switch _ A O RS-485 riser '8 terminals Remote keyswitch terminals ,^l JIl Expander cable ° Power terminals terminals Communication :=• O LEDs " • 0 • a Expander O '31M ... Mounting slot • EXPANDER CABLE Expander cable I` 11 Expander cable terminals 'f.' .„f'” terminals ••- O 0 DIP switch settings O 11 ................._.........._........_........._..._....... --_............................_........_......_.__........................ Switch Description and values ° _.._..............__ --- - O S1 to S5 The annunciator network address(in binary). Network The factory setting is for address 2. address Examples: 10000=1 01000=2 11000=3 00100=4 own• •••- S6 Network OFF=9600 baud(factory default setting) baud rate ON=38,400 baud ............_....---..._.........-.................__.._—.................................I...............-----...................-._._..._._._.'._....... S7 to SS Not usedMOUNTING RING ----'-- "' EXPANDER ELECTRICAL BOX Annunciator Enclosures The RA Remote Annunciator Enclosures provide secure,surface mounted protection for annunciators and extenders. Each con- .._.._......_._ ----._...... sists of a back plate, hinged cover, and key lock. The enclosures are 16-gauge welded steel with a white,painted 6.0 in finish.Each enclosure includes a security lock and two keys.The 15.2 cm two-and three-position enclosures have wiring channels for cor- H rect routing of interconnections. The enclosures attach to a standard electrical box,and provide a (VE pliedmounting lip that takes the place of the integral mounting ring sup- UU��IIII�I plied with the annunciators and expanders. 0.9 in 2.3 crr R4-ENC1 tom. .5 in ,1 244.1 cm �l 2.0 in c C 9.8 in 5.1 cm 24.9 cm VIII Dimensions(H x W x D) RAENCI 6.3x9.8x2.0in(16.0x24.9x5.1 cm) RA-ENC2 12.0x9.8x2.0in(30.5x24.9x5.1 cm) RA-ENC3 17.7 x 9.8 x 2.0 in(45.0 x 24.9 x 5.1 cm) RA-ENC3 Note:Allow approximately 2 inches(50 cm)clearance on both sides of the enclosure,to permit inserting and removing the key,and opening the door R4-ENC2 through 90 degrees. Page 3 of 4 D AT A 5 H M L I K85005-0128 Not to bF? Used for h sa<,li::i' Issue 1 Specifications Kidde RLCD-C RLCD RLED-C RLED24 — Operating voltage 24 VDC,continuous. Standby current 99 mA 98 mA 28 mA 6 mA ........................................................................................................................................................_...................._.._—....................... ......................... Technology that saves lives Alarm current 115 mA 113 mA 62 mA 34 mA Contact us... RS-485 communications Class A or Class B,9600 baud Email:kidde.fireefs.utc.com Data wiring 18 to 14 AWG(1.0 to 2.5 sq mm)twisted pair(6 twists per foot Web: Kidde.com/EngineeredSystems minimum).Maximum wire run is 4,000 ft.(1,219 m) Remote key switch circuit 5 VDC at 1 mA,power-limited,unsupervised Kidde is a UTC brand. Ground fault impedance 0 1016 Corporate Park Drive —...._.................._..........._.__..___........................._.__..........._......�__..................._.__..__... ...........---.._..__._.. .....................__............-----_...................... p Power Mebane,NC 27302 wiring 18 to 14 AWG(1.0 to 2.5 sq.mm) -- Display area 4 lines of 20 characters each —__._—_......_... ..........._................. ................ . ....._._....._... - ___ ----- ®2016 United Technologies Corporation. Dimensions(H x W x D) 5-5/8 x 8-1/2 x 1-1/2 in.(14.3 x 21.4 x 3.8 cm) All rights reserved. _______...._._..___...........-_-...— -- Mounting North American 4-inch square electrical box or listed enclosure - Agency Listing UL,ULC .........._........__--.-...._................. ._...................._. —__.--__ ............... Operating environment Temperature:32 to 120°F(0 to 49°C)Humidity:0 to 93%RH, noncondensing at 90°F(32°C) Ordering Information Part Description Remote Annunciators K-RLCD LCD text annunciator without common controls.English. K-RLCD-R LCD text annunciator without common controls.English.Red. — K-RLCDF LCD text annunciator without common controls.French. K-RLCD-C LCD text annunciator with common controls.English. K-RLCD-CR LCD text annunciator with common controls.English.Red. K-RLCD-CF LCD text annunciator with common controls.French. -----..._............._._.D. --_-........................._____.__......_........_..---..._........._.—.__.........--- — ._._......._.. K BLED C 16 pair LEzone annunciator with common controls.English. ...................................................................._......................................................_..._._.._.........................__.........................._.._......................................._..---._......................... K-RLED-CR _.......... _. i 6 pair LED zone annunciator with common controls.English.Red. K-RLED-CF 16-pair LED zone annunciator with common controls.French. Remote Expanders -----..._.__...._.._....._....................................................._-....._.........._.............. ........................................................................................... z—one--- K-RLED24 24-pair LED zone expander with expander cable and zone card Insert. K-RLED24R 24-pair LED zone expander with expander cable and zone card insert.Red. Enclosures --..—----------_.._.._...bion e --._ __-.._...._....—_...__—._..............._..--..._..- --........_............. RA-ENCi One-position enclosure for Remote Annunciator. RA-ENC2 Two-position enclosure for Remote Annunciator and one Remote Expander, including one interconnection cable. RA-ENC3 Three-position enclosure for Remote Annunciator and two Remote Expanders, including two interconnection cables. ---�_.............__..................._....._ __.._........—..__....._.._...._..........._................_........................._..........-------....._..............._...._........................................._.. _------- _ LSRA MIR-SB Surface Mount Box-for single R Series annunciator. Graphic Annunciator Drivers GCI Graphic Annunciator Driver,provides outputs for common indicators and 32 alarm/supv zones as well as inputs for common switches.Provided with a snap track for mounting in custom graphic enclosures. Accessories RKEY Remote key switch on plate for enabling common controls(Lock/UnIock)........ 27193 16 Electrical box,surface mount,white,single-gang,for RKEY. 0 Page 4 of 4 DATA S i-1 E . K85005-0128 plot ro be used for installation pure: Issue 1 1 ► Intelligent Initiating Devices K*dde A,0"t711 E 59f(HG"+ Technology that saves lives Intelligent Smoke Detector00t woo= ftkw ;00� 0011111M NNW. KI-PD '00 r L� S853 0 Overview Standard Features The KI-PD optical smoke detector brings advanced sensing Note:Some features described here may not be supported by technology to a practical design that increases efficiency,saves all control systems. Check your control panel's Installation and installation time,cuts costs,and extends life safety and property Operation Guide for details. protection capabilities.Continuous self-diagnostics ensure reli- Next generation optical smoke sensing technology ability over the long-haul,while environmental compensation helps reduce maintenance costs. e Wide 0.53 to 3.94%/ft.(1.7 to 12.35%/m)smoke obscuration Like all KI Series detectors,the KI-PD is an intelligent device that a Uses Existing Wiring gathers analog information from its optical sensor,converting this a Automatic Device Mapping data into digital signals.To make an alarm decision,the detector's on-board microprocessor measures and analyzes sensor read- e Up To 250 Total Addresses Per Loop ings and compares this information to historical data.Digital filters e Two Levels of Environmental Compensation remove signal patterns that are not typical of fires,thus virtually eliminating unwanted alarms. e Two Levels of Dirty Detector Warning e Twenty Pre-Alarm Settings e Five Sensitivity Settings e Non-Volatile Memory e Electronic Addressing e Identification of Dirty or Defective Detectors e Automatic Day/Night Sensitivity Adjustment e Bicolor(Green/Red)Status Led e Standard,Relay,Fault Isolator,and Audible Mounting Bases e Sensor Markings Provide Easy Testing Identification Pagel of 4 DATA 8 ti L E K85001-0646 N*01 to he us',d for it%faE'' Issue 1 Application Testing & Maintenance The KI-PD detects extremely small particles of combustion and Each detector automatically identifies when it is dirty or defective triggers an alarm at the first sign of smoke.Thanks to its high- and causes a"dirty detector"message.The detector's sensitiv- performance forward-scattering reflective response technology, ity measurement can also be transmitted to the loop controller.A the photoelectric smoke sensor responds quickly and reliably to sensitivity report may be printed to satisfy NFPA sensitivity mea- a wide range of fire types,especially slow burning fires fuelled by surements,which must be conducted at the end of the first year combustibles typically found in modern multi-use buildings. and every two years thereafter. The user-friendly maintenance program shows the current state Compatibility of each detector and other pertinent messages.Single detectors may be turned off temporarily from the control panel.Availability of The KI-PD detector is compatible with Kidde VS and VM series maintenance features is dependent on the fire alarm system used. panels. Accessories Installation Detector mounting bases have wiring terminals that are acces- `'�" ~ sible from the"room-side"after mounting the base to the electrical KI Series detector bases mount r' t box.The bases mount to North American 1-gang boxes and to to North American 1-gang boxes, 31h inch or 4 inch octagon boxes, 1'h inches 38 mm deep.They 3-1/2 inch or 4 inch octagon also mount to European BESA and 1-gang boxes with 60.3 mm boxes,and to 4 inch square elec- Self-locking tab fixing centers.The KI-SB4,KI-RB4,and KI-1134 mount to North trical boxes 1-1/2 inches(38 mm) American 4 inch sq.electrical boxes in addition to the above deep.They mount to European '�"^� boxes.They include the GSA-TS4 Trim Skirt,which is used to BESA and 1-gang boxes with 60.3 T cover the"mounting ears"on the base.The KI-ABST mounts to a mm fixing centers.See mounting LED Indicator 4 inch square box only. base installation and wiring for more information. Sensing and reporting technology KI-ABST/T/LF KI-SB )a-IB KI-RB GSA-LED The microprocessor in each detector provides additional benefits- Audible Base Standard Base Isolator Base Relay Base Remote LED Self-diagnostics and History Log,Automatic Device Mapping,and Remote LED GSA-LED-The remote LED connects to the KI-SB Fast,Stable Communication. or KI-SB4 Standard Base only. It features a North American size Self-diagnostics and History Log-Each KI Series detector 1-gang plastic faceplate with a white finish and red alarm LED. constantly runs self-checks to provide important maintenance in- GSA-TS4 Trim Skirt-Supplied with 4 inch bases,it can also formation.The results of the self-check are automatically updated be ordered separately to use with the other bases to help hide and permanently stored in the detector's non-volatile memory surface imperfections not covered by the smaller bases. Automatic Device Mapping-The loop controller learns where Sounder Bases-KI Series sounder bases are designed for use each device's serial number address is installed relative to other where localized or group alarm signaling is required. devices on the circuit.The mapping feature provides supervision a KI-ABST bases provide sounder capability to KI Series heat of each device's installed location to prevent a detector from being and smoke detectors.They are not intended for use with reinstalled(after cleaning etc.)in a different location from where it combination carbon monoxide detectors in Fire-plus-CO was originally mode. e KI-ABDT bases provide sounder capability to KI Series Fast Stable Communication-On-board intelligence means less smoke and heat detectors,as well as carbon monoxide information needs to be sent between the detector and the loop detectors when used with a GSA-T3T4 Temporal Pattern controller.Other than regular supervisory polling response,the Generator. detector only needs to communicate with the loop controller when a KI-ABLT bases provide 520 Hz low frequency sounder it has something new to report, capability to KI Series smoke and heat detectors,as well as carbon monoxide detectors when used with a GSA-T3T4 Temporal Pattern Generator.The KI-ABLT is suitable for ap- plications requiring low frequency audible tones. Page 2 of 4 K85001-0646 Issue 1 Typical Wiring The detector mounting bases accept#18 AWG(0.75mm2),#16 Audible Sounder Bases,Fire Mode (1.0mm% #14 AWG(1.5mm2),and#12 AWG(2.5mm2 wire sizes. A84GT,AB4G,AB4G-LF sounder bases Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred for ease of installation. Standard Detector Base KI-SB KI-SB4 KI-ABDT, p p T. KI-SB, Output KI-ABST, ®Jum ® Output Mode per cut KI-ABET: Default=Fire This is the basic mounting baseAI-) Volume Setting Cut/remove jumper for for Kidde KI Series detectors. resistance Default=High Fire plus CO The GSA-LED Remote LED isperwire Cuttremove t not exceed jumper for KI-ABST: supported by this to ohms low dEI ® ® Tone Setting Base. DRr WA DATM Default=Temporal Term Description sia. eco- an N Knot Cut/remove jumper for 1 Not Used Steady 0 2 DATAIed (+) KI-ABDT: 3 Not Used Not Used 4 DATA IN(-) 4 Remote LED(-) DATA DATA OUT 1-) 5 Remote LED(+) 6 Not Used 7 DATA OUT(-) DATA IN(+1 DATA OUT 1+) 24 Vdc in _ From signature controller To Next Device From power supply 24 Vdc out or Previous Device or previous base + + To next base or EOL relay Data in _ Data out Isolator Detector Base,KI-IB,KI-1134 From KI Device Controller + + to next KI Series device or previous device This base includes a built-in line fault isolator for use on Class A circuits.A detector must be installed for it to operate.The isolator base does not support the GSA-LED Remote LED. Warnings & Cautions The isolator operates as follows: -a short on the line causes all iso- a This detector does not operate without electrical power.As �o lators to open within 23 msec o o fires frequently cause power interruption,discuss further -at 10 msec intervals, �°o safeguards with the local fire protection specialist. beginning on one side • This detector does not sense fires in areas where smoke of the Class A DATA IN(-) i° DATA OUT(-) cannot reach the detector.Smoke from fires in walls,roofs, circuit nearest the loop or on the opposite side of closed doors may not reach the controller,the isolators >— —� close to provide the DATA IN(+) DATA OUT(+) detector. From signature Controller To Next Device next isolator down the or Previous Device • Photoelectric detectors have a wide range of fire-sensing line with power Term Description capabilities and are best suited for detecting slow,smolder- 1 Not Used -when the isolator next 2 DATA IN/OUT(+) ing fires. to the short closes,it reopens within 10 3 DATA IN(-) 4 Not used • In Canada,install according to CAN/ULC-S524 Standard for msec. 6 Not Used DATA OUT(-) the Installation of Fire Alarm Systems,CSA C22.1 Canadian The process repeats beginning on the 7 Not Used Electrical Code,and the local authority having jurisdiction. other side of the loop controller. Relay Detector Base,KI-RB,KI-RB4 Normaiy-Nurnaty- This base includes a relay. Nor- mally Open or Normally Closed operation is selected during installation.The dry contact is rated for 1 amp(pilot duty) 30 Vdc.The relay's position is supervised to avoid accidentally jarring it out of position.The KI-RB DATJN(-) 4j Z DATA CM can be operated as a control relayif programmed to do so at DATA IN(.) DATA OUT(+) p 9 From signature Controller To Next Device the control panel.The relay base aRevousDevice Term Descripton does not support the GSA-LED T ND, a y open Remote LED. CONTACT RATING 2 DATA IN/OUT(+) 1.0 Amp®30 VDC 3 Common (Pool Duty) 4 DATA IN(-) 5 Not Used 6 Normally-Closed 7 DATA OUT- Page 3 of 4 D A K85001-0646 F Issue 1 u.o .,. Dimensions Kidde Technology that saves lives low r1:e J 1 Contact us... Email: kidde.fire@fs.utc.com f Web: kidde.com/engineeredsystems ! 1016 Corporate Park Drive Mebane,NC 27302 Kidde is a registered mark in the United States -z aeah and other countries. ®2018 Walter Kdde Portable Equipment. All rights reserved. Specifications Operating voltage 15.20 to 19.95 VDC Normal operating current 51 uA — -----._......_—.........._.__..._._._.........._.................._....6 __. ...—._..._.._.......---------.........._.. _.... ---.—._.................... Alarm current 68 uA Smoke Sensitivity Range UL/ULC:0.53 to 3.94%/ft.(1.7 to 12.35%/m)obscuration Vibration level 10 to 35 Hz,with an amplitude of 0.01 in. Air veloci t y 0 --...,00.0.......................ft./min..........(0........to_..............20.....m/s........)................._....--__._......._-..................................... _— ..-..................... to 4 Wall mounting 12 in.(305 mm)max.from ceiling Compatible bases See Ordering Information Compatible detector testers Testifire 1000,Testifire 2000 Operating environment 32­6­11 20°F(0 to 49°C),0 to 93%R_H,nonconde_nsing Construction High Impact Engineering Polymer,White Storage temperature -4 to 140°F(-20 to 60°C) Environmental compensation Automatic — —.._.._.............................._.. ..... .-..............................._.._._............_.__.-....................---- ----..._............_....__..._..._..----..._......._.......... Agency Listings CAN/ULC-S529,UL 268,UL 268A Ordering Information Catalog Description Ship Wt. Numberlbs(kg) KI-PD Intelligent Optical Smoke Detector0.4(0.16) Accessories KI-SB Detector Mounting Base-Standard KI-SB4 4-inch Detector Mounting Base c/w Trim Skirt KI-RB Detector Mounting Base w/Relay KI-RB4 4-inch Detector Mounting Base w/Relay, c/w Trim Skirt 0.2(.09) . ................. ......._._....._.......-- ......................-------......................__...._.._........................_.....-— KI-IB Detector Mounting Base w/Fault Isolator KI-IB4 44nch Detector Mounting Base w/Fault Isolator,c/w Trim Skirt GSA-LED Remote Alarm LED(not for EN54 applications) KI-ASST Audible(Sounder)Base for Fire Detectors 0.3(0.15) __.__._......._..........__._......_.................._._................_q__.._..__._y....-_._-- _r-)-----,-...._.r--- ---...................to —..)...... KI-ABET Low Fre uenc Audible Sounder Base for CO and Fire Detectors 0.3(0.15_ KI-ABDT Audible(Sounder)Base for CO and Fire Detectors 0.3(0.15) GSA-TS4 Trim Skirt(supplied with 4-inch bases) 0.1 (0.04) GSA-TS Trim Skirt-(optional for non 4-inch bases) 0.1 (0.04) GSA-DMP Detector Mounting Plate 3.0(1.4) 0 Page 4 of 4 T AT A ;S H E F T K85001-0646 m Not to hr; us-3d for installation pisrpose­ Issue 1 Kidde E L E C T R O N t C i t A D D R E S S I Technology that saves lives Manual Pull PULL StationsN CASE OF FIRE GSA-M270, GSA-M270P, GSA-M278 ' GSA-M270 SERIES U� GSA M278 M• uLC 7150-1483: 0136 MEA S2318 Overview • Break glass operation The GSA-M270 and GSA-M278 series Manual Pull Stations are An up-front visible glass rod on the GSA-M270 discourages tampering. part of Kidde's Signature Series system.The GSA-M270 Fire Alarm Manual Pull Stations feature our very familiar teardrop • Intelligent device with integral microprocessor shape.They are made from die-cast zinc and finished with red All decisions are made at the station allowing lower com- epoxy powder-coat paint complemented by aluminum colored munication speed while substantially improving control panel stripes and markings. With positive pull-lever operation, one pull response time. Less sensitive to line noise and loop wiring on the station handle breaks the glass rod and turns in a posi- properties; twisted or shielded wire is not required. tive alarm,ensuring protection plus fool-proof operation.Presignal . ADA Compliant models(GSA-M270P)are equipped with a general alarm(GA) Meets ADA requirements for manual pull stations. keyswitch for applications where two stage operation is required. The up-front highly visible glass rod discourages tampering, but is • Electronic Addressing with Non-volatile memory not required for proper operation. Permanently stores programmable address, serial number, type of device,and job number.Automatically updates historic Kidde's double action single stage GSA-M278 station is a contem- information including hours of operation,last maintenance porary style manual station made from durable red colored lexan. date, number of alarms and troubles, and time and date of last To initiate an alarm,first lift the upper door marked"LIFT THEN alarm. PULL HANDLE",then pull the alarm handle. • Automatic device mapping Each station transmits wiring information to the loop control- Standard Features ler regarding its location with respect to other devices on the Note:Some features described here may not be supported by all control sys- circuit. tems.Check your control panel's Installation and Operation Guide for details. • Stand-alone operation • Traditional familiar appearance The station inputs an alarm even if the loop controller's polling GSA-M270 models feature our familiar teardrop design with interrogation stops. simple positive pull action and sturdy die-cast metal body. • Diagnostic LEDs • One stage(GA),two stage(pre-signal),and double action Status LEDs;flashing GREEN shows normal polling;flashing models RED shows alarm state. GSA-M270 models are available for one or two stage alarm • Designed for high ambient temperature operation systems.The single stage double action GSA-M278 features a Install in ambient temperatures up to 120°F(49°C). rugged Lexan housing with keyed reset mechanism. Page 1 of 4 K85001-0279 Issue 1 Application Typical Wiring The operating characteristics of the fire alarm stations are deter- The fire alarm station's terminal block accepts#18 AWG(0.75mm� mined by their sub-type code or"Personality Code".NORMALLY- to#12 AWG(2.5mm�wire sizes.See Signature Loop Controller OPEN ALARM-LATCHING(Pesonality Code 1)is assigned by the catalog sheet for detailed wiring requirement specifications. factory;no user configuration is required.The device is configured for Class B IDC operation.An ALARM signal is sent to the loop tiring Notes controller when the station's pull lever is operated.The alarm con- 0 Refer to Signature Loop Controller manual for maximum dition is latched at the station. wire distance. 2. All wiring is power limited and supervised. Compatibility REARVIEW of 278 Signature Series manual stations are compatible only with Kidde's Signature Loop Controller. e o ° O Warnings & Cautions This device will not operate without electrical power.As fires fre- quently cause power interruption,we suggest you discuss further (,�,n//A�) -- - p , ------ (No'Man safeguards with your local fire protection specialist. Testing & Maintenance To test(or reset)the station simply open the station and operate DATA IN C-) DATA OUT(+)l the exposed switch.The GSA-M270 series are opened with a tool; DATA IN(-) DATA( the GSA-M278 requires the key which is supplied with that station. From Signature controner To Next Device ar Re%4ms Device /, The station's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message.The user-friendly maintenance Figure 4. Single Stage Systems program shows the current state of each Signature series device and other pertinent messages.Single devices may be deactivated temporarily,from the control panel.Availability of maintenance MEW features is dependent on the fire alarms stem used. REAR pe Y Of Scheduled maintenance(Regular or Selected)for proper system 270P,270M © o operation should be planned to meet the requirements of the o Authority Having Jurisdiction(AHJ). Refer to current NFPA 72 and �o ° ULC CAN/ULC 536 standards. r "z tl 7 G 5 Red LED (Alarm/AciNe) ° O O p +(DATA IN(+) DATA OUT(+) `DATA IN(-) DATA OUT(•) From Signature Controller Y To Next Device or Revbus Device Q Figure 5. Two Stage Systems Paye 2 of 4 )A i A K85001-0279 "tDt to be used fee instaWc issue 1 Installation Single-stage Signature Series fire alarm manual pull stations mount to North American 2112 inch(64 mm)deep 1-gang boxes. Two stage presignal(270P)models require 11/2 inch(38 mm)deep 4-inch square boxes with 1-gang,Y2-inch raised covers.Openings must be angular.Rounded openings are not acceptable. Recommended box:Steel City Model 52-C-13;in Canada,use Iberville Model CI- 52-C-49-1/2. All models include terminals are suited for#12 to#18 AWG(2.5 mm2 to 0.75 mm2)wire size. Kidde recommends that these fire alarm stations be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing: The loop controller electronically addresses each manual station,saving valuable time during system com- missioning.Setting complicated switches or dials is not required.Each station has its own unique serial number stored in its on-board memory.The loop controller identifies each device on the loop and assigns a"soft"address to each serial number.If desired,the stations can be addressed using the SIGA-PRO Signature Program/Service Tool. Key-Latch Compatible Electrical Box Compatible Electrical Box Cover Release Cover Release r ` Screw m o l'1 Back O ��� o Back Plate O` Plate 0 Toggle Toggle Switch Switch O pRMAL µ o Glass Rod Glass Rod Release Lever r OPEN .� O Figure 1. GSA-M278 installation Figure 2. GSA-M270 installation Cover Release Scr w / /- ��--CompaBble Electrical Boxy with VWnch raised covers---►� k ®Q Back � . plate �y Toggle Switch , NORMAL O, •a Glass Rod t AA Releose Lever Do nouse boxes with rounded openings. Figure 3. GSA-M270P installation Page 3 of 4 L A g u t4 L.1 K85001-0279 Not to be U ted for installalion purposes. Issue 1 Specifications �'��� Catalog Number GSA-M270 GSA-M270P, GSA-M278 Description Single Action Single Action-Two Double Action -One Stage Stage(Presignal) -One Stage Technology that saves lives Addressing Uses 1 Module Uses 2 Module Uses 1 Module Requirements Address Addresses Address ..---..._.........._........................_..—._.._.................._........................................................— -...._................................................................_................................._...._..........................................-. Contact us... Operating Current Standby=250pA Standby=396pA Standby=250pA Email:kidde.fire@fs.utc.com Activated=400pA Activated=680pA Activated=400pA Web: Kidde.com/EngineeredSysfems Diecast Zinc-Red Epoxy Lexan-Red with Construction 8 Finish with aluminum markings white markings Kidde is a UTC brand. Type Code Factory Set --.................... ...._.. -- .._........--......-............. -_........._........ ....._..............- --- 1016 Corporate Park Drive Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) Mebane,NC 27302 _........................................................................................................................................................................._......................................................................._............................................._.....--..............._. Stora e and O eratin Operating Temperature:32°F to 120°F(0°C to 49°C) g p g Storage Temperature:-4°F to 140°F(-20°C to 60°C)Humidity:0 to 93% ©2016 United Technologies Corporation. Environment RH All rights reserved. On-board Green LED-Flashes when polled LED Operation On-board Red LED-Flashes w hen in alarm — -_____—_—....-_--._ _.. _.............._..._............_....-.._...._................ _.._....__.. Compatibility Use With:Signature Loop Controller ---...................—. ......._........_...._..__..__.._........_.............._.._.._....._........ ...................................................__................ _.... Agency Listings UL,ULC,MEA,CSFM,FM Ordering Information Ship Catalog Wt.lbs Number Description (kg) GSA-M270 One Stage Fire Alarm Station, English Markings -UL/ULC Listed ............... - --........................................................................_-. .....................------.._..................---._.............- GSA-M270P Two Stage(Presignal)Fire Alarm Station,English Markings 1 (0.5) -UL/ULC Listed GSA-M278 Double Action(One Stage)Fire Alarm Station,English Markings - UL/ULC Listed Accessories 270-GLR 20 Glass Rods-for GSA-M270 series (USA ONLY) 276-GLR 20 Glass Rods-for GSA-M278 series i; Page 4 of 4 D A r A SH L E: K85001-0279 Not to be used fcv m6taila',, , , Issue 1 Kidde 6 ►Intelligent Input-Output0 Ar E C re A D DD R E SSS I N G Technology that saves lives Input Modules GSA-CT1 , GSA-CTI NT, • GSA-CT2, GSA-MCT2 & MEA k� 7 Q 4, _.�,1 7300 1483: w 0115 5 GSA-CTI/2 GSA-MCT2 LC S3424 Overview Standard Features The GSA-CT1 Single Input Module,GSA-CTi HT High Tempera- • Multiple applications ture Single Input Module and GSA-CT2/GSA-MCT2 Dual Input Including Alarm,Alarm with delayed latching(retard)for water- Modules are intelligent analog addressable devices used to con- flow applications,Supervisory,and Monitor.The installer selects nect one or two Class B normally-open Alarm, Supervisory,or one of four"personality codes"to be downloaded to the mod- Monitor type dry contact Initiating Device Circuits(IDC). ule through the loop controller. The actual function of these modules is determined by the"personal- • GSA-CT1 HT rated for high temperature environments ity code"selected by the installer.This code is downloaded to the Suitable for attic installation and monitoring high temperature module from the Signature loop controller during system configura- heat detectors. tion. • Plug-in(UIO)or standard 1-gang mount The input modules gather analog information from the initiating UIO versions allow quick installation where multiple modules are devices connected to them and convert it into digital signals. required.The 1-gang mount version is ideal for remote loca- tions that require a single module. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. • Automatic device mapping Signature modules transmit information to the loop controller The GSA-CTi,GSA-CTI HT and GSA-CT2 mount to standard regarding their circuit locations with respect to other Signature North American 1-gang electrical boxes,making them ideal for lo- devices on the wire loop, cations where only one module is required.Separate 1/0 and data . Electronic addressing loop connections are made to each module. Programmable addresses are downloaded from the loop con- The GSA-CT1 HT module operates at an expanded temperature troller,a PC,or the Signature Program/Service Tool.There are range of 32 OF to 158 OF(0°C to 70°C)for those applications no switches or dials to set. requiring more extreme environmental temperature variation. • Ground fault detection by address The GSA-MCT2 is part of the UIO family of plug-in Signature Detects ground faults right down to the device level. Series modules.It functions identically to the GSA-CT2,but takes advantage of the modular flexibility and easy installation that characterizes all UIO modules.Two-and six-module UIO mother- boards are available.All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in Kidde enclosures. Page 1 of 4 D AT A S t K85001 -0241 Not to be used for ins'.. . Issue 1 Signature Series Overview UiD Motherboard The - Signature Series intelligent analog-addressable addressable s stem from 6-32 9 9 g y Self-tapping Kidde Security is an entire family of multi-sensor detectors and screws mounting bases,multiple-function input and output modules, N(U10) network and non-network control panels,and user-friendly mainte- PluCaptive nance and service tools.Analog information from equipment con- Module screws nected to Signature devices is gathered and converted into digital signals.An onboard microprocessor in each Signature device - - measures and analyzes the signal and decides whether or not to ns Flat washers input an alarm.The microprocessor in each Signature device pro- - vides four additional benefits—Self-diagnostics and History Log, --Cabinet or electrical enclosure Automatic Device Mapping,and Fast, Stable Communication. Self-diagnostics and History Log—Each Signature Series Electronic Addressing-The loop controller electronically ad- device constantly runs self-checks to provide important mainte- dresses each module,saving valuable time during system com- nance information.The results of the self-check are automatically missioning.Setting complicated switches or dials is not required, updated and permanently stored in its non-volatile memory.This Each module has its own unique serial number stored in its information is accessible for review any time at the control panel, on-board memory.The loop controller identifies each device on PC,or using the Signature Program/Service Tool. the loop and assigns a"soft"address to each serial number.If Automatic Device Mapping The Signature Data Control- desired,the modules can be addressed using the Signature Pro- ler(SDC)learns where each device's serial number address is gram/Service Tool. installed relative to other devices on the circuit.The SDC keeps a Kidde recommends that this module be installed according to lat- map of all Signature Series devices connected to it.The Signature est recognized edition of national and local fire alarm codes. Series Data Entry Program also uses the mapping feature.With interactive menus and graphic support,the wired circuits be- tween each device can be examined.Layout or"as-built"drawing Application information showing branch wiring(T-taps),device types and their address are stored on disk for printing hard copy. The duty performed by the GSA-CT1 and GSA-CT2/MCT2 is de- termined by their sub-type code or"Personality Code".The code is selected by the installer depending upon the desired application Installation and is downloaded from the loop controller. GSA-CT1,GSA-CTI HT and GSA-CT2:modules mount to North One personality code can be assigned to the GSA-CT1.Two per- American 2'/2 inch(64 mm)deep 1-gang boxes and 1'/2 inch(38 sonality codes can be assigned to the GSA-CT2/MCT2. Codes mm)deep 4 inch square boxes with 1-gang covers and GSA-MP 1, 2,3 and 4 can be mixed on GSA-CT2/MCT2 modules only.For mounting plates.The terminals are suited for#12 to#18 AWG(2.5 example,personality code 1 can be assigned to the first address MM2 to 0.75 m ire size. (circuit A)and code 4 can be assigned to the second address Compatible electrical box (Circuit B). NORMALLY-OPEN ALARM-LATCHING(Personality Code 1) -Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact initiating devices such as Pull Stations,Heat Detectors,etc.An ALARM signal is sent to Wall plate,white the loop controller when the input contact is closed.The alarm (1-gang) condition is latched at the module. 1 NORMALLY-OPEN ALARM-DELAYED LATCHING(Person- ality Code 2)-Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiat- ing devices such as Waterflow,Alarm Switches.An ALARM signal is sent to the loop controller when the input contact is closed for Status LEDs '. approximately 16 seconds.The alarm condition is latched at the module. LED viewing ports NORMALLY-OPEN ACTIVE-NON-LATCHING(Personality Q Code 3)-Assign to one or both circuits.Configures either circuit A or B or both for Class B normally-open dry contact monitoring input such as from Fans, Dampers,Doors,etc.An ACTIVE signal GSA-MCT2:mount the UIO motherboard inside a suitable Kidde is sent to the loop controller when the input contact is closed.The enclosure with screws and washers provided. Plug the GSA- active condition is not latched at the module. MCT2 into any available position on the motherboard and secure NORMALLY-OPEN ACTIVE-LATCHING(Personality Code the module to the motherboard with the captive screws.Wiring 4)-Assign to one or both circuits. Configures either circuit A or connections are made to the terminals on the motherboard(see B or both for Class B normally open dry contact monitoring input wiring diagram). UIO motherboard terminals are suited for#12 to such as from Supervisory and Tamper Switches.An ACTIVE signal #18 AWG(2.5 mm2 to 0.75 mm2)wire size. is sent to the loop controller when the input contact is closed.The active condition is latched at the module. Page 2 of 4 D A.(A S r_i L t K85001-0241 Not io be used ter instaliti Issue 1 Typical Wiring Modules will accept#18 AWG(0.75mm2),#16(1.0mm2),and#14AWG(1.50mm2), and#12 AWG(2.50mm�wire sizes. Note:Sizes#16 AWG(1.Omm2)and#18 AWG(0.75mm�are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating(Slave)Device Circuit Wire Specifications _.__...._.__......_._......_...................__.._... _ ....__.._...........__....___.._................_................................_............_.........................---._..._......._........_.................._...._..........._..----__...................._.__._-__.___........-_..........................__......_............................... . Maximum Allowable Wire Resistance 50 ohms(25 ohms per wire)per Circuit __. —. — Maximum Allowable Wire Capacitance 0.1 pF per Circuit For Design Reference: Wire Size Maximum Distance to EOLR #18 AWG(0.75 mm� _........ #16 AWG(1.00 mrM 4,000 ft(1,219 m) #14 AWG(1.50 mrno #12 AWG(1.50 mrM Typical N.O.Initiating Device Typical N.O.Initiating Device + I INPUT INPUT A&A style B(class B) TB2 ' I TB2 8 7 -` UL/ULC Listed Style B(Class B) e rDATA • • �• 47KO EOL UUULC Listed UL/ULC Usted 47Kn EOL Qj Q Q4 • 47KO EOL Red LED Green LED (Alarm/ActNe) ® �' (Normal) Red LED � Green LED 4 3 2 1 Warm/Active) 4 3 (Normal) TBI TBI 7, ( ff DATA IN(+) DATA OUT W (r DATA IN(+) 1DATA IN(-) DATAOUT(-) DATA IN(-) 1 To Next Device From Signature Controller To Next Device From Signature Controller or Previous Device or Previous Device Q GSA-CT1,GSA-CT1 HT GSA-CT2 iypcolHOiniM1°4nq Ounce NOTES uvu'c�.e<a uvuLc❑n.a W EOL input2 °pull e7•LV EOI Q Maximum 25 Ohm resistance per wire. ©Maximum 812 AWG(2.5 mm2)wire;Minimum#18 AWG(0.75 mm2). A q , ©Refer to Signature controller installation sheet for wiring specifications. ®Maximum 10 Vdc®350 NA M(Tq ©The GSA-UI06R and the GSA-UI02R do not come with TB14. 2" Ul e•n••mOrlwE d 6 All wiring is supervised and power-limited. 7 These modules will not support 2-wire smoke detectors. 4 i 0 1 Sign°ture T810 NO corne[lare.reylY04lOr C' M[Tq Cn wt TG7 Gmq at+ •rrrc°one "gr�•vur• Warnings & Cautions - z Green LEDI-10 TAT module will not operate without electrical power.As fires fre- W4 LEOW quently cause power interruption,we suggest you discuss further safeguards with your local fire protection specialist. pwW IOf MCR. Compatibility GSA-MCT2 These modules are part of Kidde's Signature Series intelligent pro- cessing and control platform.They are compatible with VM, and VS Series control panels. Page 3 of 4 D A'�k s i l WU: T K85001-0241 'Not to be UseC for instalf: Issue 1 Specifications idde Catalog Number GSA-CTiHT GSA-CTi DSA-CT2 GSA-MCT2 - .......... ... ..... .......1................._ ..........................:...........- ........._......__..........:...:�....... _ _........................ Description Single Input Module Dual Input Module Type Code 48(factory set)Four sub-types 49(factory set)Four sub-types Technology that saves lives (personality codes)are available (personality codes)are available Address Requirements Uses One Module Address Uses Two Module Addresses Contact us... Operating Current Standby=25OpA; Standby=396VA; Email:kidde.fire®fs.utc.com Activated=400pA Activated=68OpA Web: Kidde.com/EngineeredSystems Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) — Construction High Impact Engineering Polymer Kiddeis a UTC brand. _______-___._......................................;...._._-_-----____---.._.._..__._..__._...._.._....---._..._.__._..,--..-.-- -- KiddCor orate Park Drive Mounting North American 21/2 inch(64 mm)deep one-gang box- U102R/6R/6 Mebane,NC 27302 1016 es and 11h inch (38 mm)deep 4 inch square boxes i Motherboard with one-gang covers and GSA-MP mounting plates .. ....................................................:. —..._._.............................._ ©2016 United Technologies Corporation. Operating Environment 32 F to 158°F 32°F to 120°F(0°C to 49,C) All rights reserved. (OOC to 70°C) Storage Environment -4°F to 140°F(-20°C to 60°C);Humidity:0 to 93%RH LED Operation On-board Green LED-Flashes when polled;On-board Red LED- Flashes when in alarm/active. Both LEDs-Glow steady when in alarm _....__._......_......._.._..._..._._._......................----._..._... ----.._._.........._.... -_._-.._..................... - -.._ -- --...........-- Compatibility Use with Signature Loop Controller Agency Listings I UL,ULC, MEA,CSFM Ordering Information Catalog Ship Wt. Number Description lbs(kg) GSA-CT1 Single Input Module- UL/ULC Listed 0.4(0.15) --..............................................._.__..._._..............._...._...... _ ...................................._....__-......................_.__...----...................._ _GSA-CTiHT Single Input Module High Teperature Operation UL/ULC Listed 0.4(0.15) GSA-CT2 Dual Input Module-UL/ULC Listed 0.4(0.15) GSA-MCT2 Dual Input Plug-in(UIO)Module -UL,ULC Listed 0.1 (0.05) Related Equipment 27193-11 Surface Mount Box-Red,1-gang 1.0(0.6) --......... _._.........._-.....---...._................................. _._...._.._. 27193-16 Surface Mount Box-White, 1-gang 1.0(0.6) _........................ _..... - ---............- ---- ................................. ......................_.._..................... --._....-------.._-_................... GSA-U102R Universal Input-Output Module Board w/Riser Inputs 0.32(0.15) -Two Module Positions _ GSA-UI06R Universal Input-Output Module Board w/Riser Inputs 0.62(0.28) -Six Module Positions GSA-U106 Universal Input-Output Module Board -Six Module Positions 0.56(0.25) MFC-A Multifunction Fire Cabinet-Red,supports Signature Module 7.0(3.1) Mounting Plates GSA-MB4 Transponder Mounting Bracket(allows for mounting 0.4(0.15) two 1-gang modules in a 2-gang box) GSA-MP1 Signature Module Mounting Plate, 1 footprint 1.5(0.70) GSA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5(0.23) ......................__---- __._....................._........----......_. GSA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02(0.46) P Page 4 of 4 DATA S H E E K85001-0241 Not to be used ter in;tai(ation purposes. Issue 1 K+ <=:,.,.:1: .1►Intelligent Input/output • Kidde Technology that saves lives control Relay Modules GSA-CR, GSA-MCR, GSA-CRR, `- GSA-MCRR r , , . MEA I gQ — 7300-1483 R 0115 j GSA-t:R �L GSA-MCR 53424 Overview Standard Features The Control Relay Module and the Polarity Reversal Relay Module • Provides one no/nc contact(GSA-CR/MCR) are part of the Signature Series system.They are intelligent analog Form"C"dry relay contact can be used to control external ap- addressable devices available in either plug-in(UIO)versions,or pliances such as door closers,fans,dampers etc. standard 1-gang mount versions. • Allows group operation of sounder bases The GSA-CR/MCR Control Relay Module provides a Form"C" The GSA-CRR/MCRR reverses the polarity of its 24 Vdc out- dry relay contact to control external appliances such as door clos- put,thus activating all Sounder Bases on the data loop. ers,fans,dampers etc.This device does not provide supervision • Plug-in(UIO)or standard 1-gang mount of the state of the relay contact. Instead,the on-board micro- UIO versions allow quick installation where multiple modules processor ensures that the relay is in the proper ON/OFF state. are required.The 1-gang mount version is ideal for remote Upon command from the loop controller,the GSA-CR/MCR relay locations that require a single module. activates the normally open or normally-closed contact. . Automatic device mapping The GSA-CRR/MCRR Polarity Reversal Relay Module provides Signature modules transmit information to the loop controller a Form"C dry relay contact to power and activate a series of regarding their circuit locations with respect to other Signature GSA-AB4G Audible Sounder Bases.Upon command from the devices on the wire loop. Signature loop controller,the GSA-CRR reverses the polarity of its a Electronic addressing 24 Vdc output,thus activating all Sounder Bases on the data loop. Programmable addresses are downloaded from the loop con- Standard-mount versions(GSA-CR and GSA-CRR)are troller,a PC,or the SIGA-PRO Signature Program/Service Tool; installed to standard North American 1-gang electrical boxes, there are no switches or dials to set. making them ideal for locations where only one module is re- • Intelligent device with microprocessor quired.Separate 1/0 and data loop connections are made to each All decisions are made at the module to allow lower com- module. munication speed with substantially improved control panel Plug-in UIO versions(GSA-MCR and GSA-MCRR)are part of response time and less sensitivity to line noise and loop wiring the UIO family of plug-in Signature Series modules.They function properties;twisted or shielded wire is not required. identically to the standard mount versions,but take advantage of Ground fault detection by address the modular flexibility and easy installation that characterizes all Detects ground faults right down to the device level. UIO modules.Two-and six-module UIO motherboards are avail- able.All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in Kidde enclo- sures. Page 1 of 0 DATA S€ 'G'r K85001-0239 Not to be usod for installafion purpose: Issue 1 Installation Application GSA-CR and GSA-CRR:modules mount to North American 212 The operation of Signature Series control relays is determined by inch(64 mm)deep 1-gang boxes and 11/2 inch(38 mm)deep 4 their sub-type code or"Personality Code." inch square boxes with 1-gang covers and GSA-MP mounting personality Cade 8:CONTROL RELAY(GSA-CR/MCR)-Dry plates.The terminals are suited for#12 to#18 AWG(2.5 mm2 to Contact Output.This setting configures the module to provide 0.75 mm2)wire size. one Form"C"DRY RELAY CONTACT to control Door Closers, Fans,Dampers,etc. Contact rating is 2.0 amp®24 Vdc;0.5 Compatible electrical box amp®120 Vac(or 0.25A®220 Vac for non-UL applications). Personality Code 8 is assigned at the factory. No user configura- tion is required. Personality Code 8:POLARITY REVERSAL RELAY MODULE (GSA-CRR/MCRR).This setting configures the module to reverse Wall plate,white the polarity of its 24 Vdc output.Contact rating is 2.0 amp @ 24 • (1-gang) Vdc(pilot duty).Personality Code 8 is assigned at the factory. No user configuration is required. 4 a a o Compatibility These modules are part of Kidde's Signature Series intelligent pro- Status LEDs cessing and control platform.They are compatible with VM,and LED viewing ports �� VS Series control panels. • ,,� Q b Warnings & Cautions This module will not operate without electrical power.As fires fre- GSA-MCR and GSA-MCRR:mount the UIO motherboard inside quently cause power interruption,we suggest you discuss further a suitable Kidde enclosure with screws and washers provided. safeguards with your local fire protection specialist. Plug the module into any available position on the motherboard and secure the module to the motherboard with the captive screws.Wiring connections are made to the terminals on the Testing & Maintenance motherboard(see wiring diagram).UIO motherboard terminals are suited for#12 to#18 AWG(2.5 mm2 to 0.75 mm2)wire size. The module's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message.The user-friendly maintenance 1.110 Motherboard program shows the current state of each module and other per- 6-32 tinent messages.Single modules may be turned off(deactivated) sen-tapping temporarily,from the control panel.Availability of maintenance screws features is dependent on the fire alarm system used. Scheduled maintenance(Regular or Selected)for proper system operation Plug-in(U10) Captive should be planned to meet the requirements of the Authority Hav- Module screws ing Jurisdiction(AHJ).Refer to current NFPA 72 and ULC CAN/ -- fl--� ULC 536 standards. ki3 Flat washers —Cabinet or electrical enclosure Electronic Addressing-The loop controller electronically ad- dresses each module,saving valuable time during system com- missioning.Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on- board memory.The loop controller identifies each device on the loop and assigns a"soft"address to each serial number.If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. Kidde recommends that this module be installed according to lat- est recognized edition of national and local fire alarm codes. Page 2 of 6 DATA .777 : K85001-0239 Not iQ be used to installation purpose: Issue t Typical Wiring Modules will accept#18 AWG(0.75mml,#16(1.0mmq,#14 AWG(1.50mm�and#12 AWG(2.5mm�wire sizes. Note:Sizes#16 AWG(1.0mmj and#18 AWG(0.75mml are preferred for ease of installation.See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Normally- Normally- Open Common Closed TB2 8 7 6 Red LED rGreen LED (Alarm/Active) U 0 (Normal) 4 3 2 1 TB1 Notes Q Refer to Signature Loop Controller Installation DATA IN Sheet for wiring specifications. (+) DATA OUT(+) 1 DATA IN(-) > DJ} A NFPA 72 requires that the GSA-CR/GSA-MCR ATA OUT() be installed in the same room as the device it is From Signature Controller To Next Device controlling.This requirement may not apply in all or Previous Device markets.Check with your local AHJ for details. 0 l ®The GSA-UI06R and the GSA-U102R do not come GSA-CR Control Relay with TBI 4. ®The GSA-UI06 does not come with TB8 through TB13. Normally Open Common Normally Closed ®Supervised and power-limited. ® If the source is nonpower-limited,maintain a space of 1/4 inch from power-limited wiring or use FPL,FPLP,FPI-R,or an equivalent in accordance Lwith the National Electrical Code. 0 7) Maximum#12 AWG(2.5mml wire. Q1 2 3 4 Min.#18(0.75mm'). 1 Data In+ A 4 4 3 3 2 2 � 1 T87 T814 + No connections required for Data Out MCR.Other modules may require connections. d m z oc v 4 u F 3 2 Green LED(Normal) 91 Red LED(Active) ••! T815 s• 1234 A No connections required for MCR.Other modules may require connections. GSA-MCR Control Relay Page 3 of 6 U A'A S W 7'-; K85001-0239 Not to be used for install: ' Issue 1 Typical Wiring Modules will accept#18 AWG(0.75mm�,#16(1.0mmj,#14 AWG(1.50mm�and#12 AWG(2.5Omm2)wire sizes. Note:Sizes#16 AWG(1.0mmj and#18 AWG(0.75mmg are preferred for ease of installation,See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. A84G A84G AB4G Audible Base Audible Base Audible Base 6254A-003 EOL Relay I I Listed 24 VDC + 11 Nominal Power aAULU-- , Q Supply _ Q JRA 0 — -- .•CR CGSA-CRR CT1 cn O O C 3 Signature a+ Controller a_ Q 0 Optional CR for disabling/disconnecting sounder base GSA-MCRR GSA-CRR Schematic GSA-MCRR Schematic ® o o P—in Rowel Out Pc1i Reeerses power In Power Out O VNten Actwftd Polanly reverses O 6254A-003 + whenact,ele.d. Z Z I - EOL Relay Audible O required for Bases _ T.- ± supe-,on + a a a a 11 d ' 15.i 1 asp- t o'< Signature B 2 Notes Data Dot.Out + • • • CI¢uit 0 Refer to the Signature controller installation sheet for For normal operation CTl wiring. 0 — For General Fire Alarm Operation n ®One Pair of Wires(24 Vdc power). UL/ULC Wed + 4 3 z 24 Vdc® power One Pair of Wires(Signature Data). supply or A Single Wire(24 Vdc power). ®The GSA-UI06R and the GSA-UI02R do not come MCRR with TB14. 2 1 UIOIRI series motherboard ®The GSA-UI06 does not come with TB8 through Data Out+ 3 Q TB13. No connections required for Signaturet 7l Supervised and power-limited. Dattet4 MCRR.Other modules may /� Circuit z require connections. 8 If the source is nonpower-limited,maintain a space TB2 of 1/4 inch from power-limited wiring or use FPL, + FPLP,FPLR,or anequivalent in accordance with the Data in_ Green LED(Normal) National Electrical Code. f _,_ Red LED(Active) z 9 Maximum#12 AWG(2.5 mm2)wire;Minimum #18 t• No connections required for AWG(0.75 mm2). Green LED(Normal) ®g Tets MCRR.Other modules may 10 End-of-Line Relay must monitor and report power Red LED(Active) require connections. supply trouble to control panel. 0 0 11 Class B Data wiring may be'T-tapped." Optional MCRR or MCR for No connections required for MCRR.Other disobling/disc.nnecting modules may require connections. an audible base. Y q Page 4 of 6 D A r A S I l E E r K85001-01239 110t to be used Ice l:rIG1al13tiOn pUr4OSO: ISSLIe 1 Specifications Catalog Number GSA-CR GSA-MCR GSA-CRR j GSA-MCRR Description Control Relay Polarity Reversal Relay _... — ...._......._..................._...__......................._........_..............._.._...---._..................._._.._......_........—...__....._.................................................................................. ........... ........... ............................. ....................................................................................................._ _...-................ __......... . Type Code Personality Code 8(Factory Set) Personality Code 8(Factory Set) Address Requirements Uses 1 Module Address Operating Current Standby=75 pA Activated=75 UA Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominaQ _..._............--.._.. --._...._.._._......—..--- ..._........................._.....----._.....----- _....._..__—_ _._............_...__------___--..._................_..._...... Relay Type and Rating Form C,2 Amps @ 24 Vdc(pilot duty),0.5 Amps 0 120 Vac and 0.25 Amps®220 Vac(220 Vac is non-UL). Not rated for capacitive loads. Mounting North American 21h inch Plugs into U102R,U106R or North American 21h inch Plugs into U102R,U106R or (64 mm)deep 1-gang boxes U106 Motherboards (64 mm)deep 1-gang boxes U106 Motherboards and 11h inch(38 mm)deep i and 11h inch(38 mm)deep 4 inch square boxes with 4 inch square boxes with i 1-gang covers and GSA-MP 1-gang covers and GSA-MP I mounting plates i mounting plates Construction&Finish High Impact Engineering Polymer . ..._.-...._...-.... .............—_.._,__.-..........-_ _-- --._........._......_._ —..._...... -...._.._.—..- ---._........ —._—..................................... Storage and Operating Operating Temperature:32°F to 120°F(0°C to 49°C) Environment Storage Temperature:-4°F to 140°F(-20°C to 60°C)Humidity:0 to 93%RH LED Operation On-board Green LED-Flashes when polled On-board Red LED-Flashes when in alarm/active Compatibility Use With:Signature Loop Controller Agency Listings UL,ULC,CSFM,MEA — Ordering Information Catalog Number Description Ship Weight-lbs -.......__..._..__ ---- ....._...... __. ...... ..--------- . _.. (k9) GSA-CR Control Relay Module(Standard Mount) 0.4(0.15) GSA-MCR Control Relay Module(UIO Mount) 0.18(0.08) GSA-CRR Polarity Reversal Relay Module(Standard Mount) 0.4(0.15) GSA-MCRR Polarity Reversal Relay Module(UIO Mount) 0.18(0.08) Related Equipment 27193-11 Surface Mount Box-Red,1-gang 1 (0-6) 27193-16 Surface Mount Box-White,1-gang 11 (0.6) ....._------...................................—�_. _ -- _ .._.__... —-- -- ..._....._..__...._._--............ ----._.._................._.._ ......-........................ GSA-U102R Universal Input-Output Module Board w/Riser Inputs-Two Module Positions 0.32(0.15) -—— —..._.......... ---- -.._......----- _.........._....._...._ GSA-U106R Universal Input-Output Module Board w/Riser Inputs-Six Module Positions 0.62(0.28) GSA-U106 Universal Input-Output Module Board-Six Module Positions 0.56(0.25) GSA-AB4G Audible(Sounder)Detector Base 0.3(0.15) Accessories MFC-A Multifunction Fire Cabinet-Red,supports Signature Module Mounting Plates 7.0(3.1) GSA-MB4 Transponder Mounting Bracket(allows for mounting two 1-gang modules in a 2-gang box) 0.4(0.15) GSA-MP1 Signature Module Mounting Plate, 1 footprint 1.5(0.70) 11............._....._...........__....................................._.....—.__......_................__..........--._....................................................................................................._.._..._.__.._................................__.................----............._._................__.........-.._-........................................_..__._._..—................................. ........ GSA-MP2 Signature Module Mounting Plate, 112 footprint 0.5(0.23) GSA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02(0.46) Page 5 of 6 D A-r. , : K85001-0239 Not to be u>ed for instalfi ' -,asps. Issue Signature Series Overview KThe Signature Series intelligent analog-addressable system from Kidde is an entire family 0��� of multi-sensor detectors and mounting bases,multiple-function input and output mod- IV X-FT-7 ules,network and non-network control panels,and user-friendly maintenance and service Technology that saves lives tools.Analog information from equipment connected to Signature devices is gathered and converted into digital signals.An onboard microprocessor in each Signature device Contact us... measures and analyzes the signal and decides whether or not to input an alarm.The mi- Email:kidde.fire@fs.utc.com croprocessor in each Signature device provides four additional benefits-Self-diagnostics Web: Kidde.com/EngineeredSystems and History Log,Automatic Device Mapping,Stand-alone Operation and Fast,Stable Communication. Kidde is a urc brand. Self-diagnostics and History Log-Each Signature Series device constantly runs self- 1016 Corporate Park Drive Mebane,NC 27302 checks to provide important maintenance information.The results of the self-check are Me automatically updated and permanently stored in its non-volatile memory.This information ®2016 united Technologies corporation. is accessible for review any time at the control panel,PC,or using the SIGA-PRO Signa- All rights reserved. ture Program/Service Tool.The information stored in device memory includes: •Device serial number,address,and type •Time and date of last alarm •Most recent trouble code logged by the detector— 32 possible trouble codes may be used to diagnose faults. Automatic Device Mapping The Signature Data Controller(SDC)learns where each device's serial number address is installed relative to other devices on the circuit.The SDC keeps a map of all Signature Series devices connected to it.The Signature Series Data Entry Program also uses the mapping feature.With interactive menus and graphic support,the wired circuits between each device can be examined.Layout or"as-built" drawing information showing branch wiring(T-taps),device types and their address are stored on disk for printing hard copy.This takes the mystery out of the installation.The preparation of as-built drawings is fast and efficient. Device mapping allows the Signature Data Controller to discover: • Unexpected additional device addresses •Missing device addresses •Changes to the wiring in the circuit. Most Signature modules use a personality code selected by the installer to determine their actual function. Personality codes are downloaded from the SDC during system configu- ration and are indicated during device mapping. Standalone Operation-A decentralized alarm decision by the device is guaranteed. Onboard intelligence permits the device to operate in standalone(degrade)mode.If Sig- nature loop controller CPU communications fail for more than four seconds,all devices on that circuit go into standalone mode.The circuit acts like a conventional alarm receiving circuit.Each Signature device on the circuit continues to collect and analyze information from its slave devices.When connected to a panel utilizing standalone operation,modules with their"personality"set as alarm devices(IDC)will alarm should their slave alarm-initiat- ing device activate. 0 Page s of 6 A ;, K85001-0239 N01 to be used fcy install:':' ;urpose: Issue 1 . ,I-Strobes,Horns,Bells,Chimes KiddeTechnology that saves lives Field Configurable or more Patents PWVWQ. Ceiling Horn Strobes ............. Genesis Series ` r �M C E 300-1657: MEA 0202 L2±j Overview Standard Features Genesis ceiling horn-strobes are small,compact,and attractive • Field configurable—no need to remove the device audible-visible emergency signaling devices. Protruding no more — 15/30/75/95 cd and 95/115/150/177 cd models available than 1.6"(41 mm),Genesis horn-strobes blend with any decor. — Switch settings remain visible even after the unit is installed Thanks to patented breakthrough technology, Kidde Genesis — Low/high dB settings strobes do not require bulky specular reflectors and lenses. • Unique low-profile design Instead,an exclusive cavity design conditions light to produce — 30 per cent slimmer profile than comparable signals a highly controlled distribution pattern.Significant development — No visible mounting screws efforts employing this new technology have given rise to a new — Available with white or red housings benchmark in strobe performance—FullUght technology. . Easy to install FullLight strobe technology produces a smooth light distribution — Fits all standard 4"square electrical boxes with plenty of pattern without the spikes and voids characteristic of specular room behind the signal for extra wire—no extension ring or reflectors.This ensures the entire coverage area receives consis- trim plate needed tent illumination from the strobe flash.As a result,Genesis strobes — Pre-assembled with captive hardware—no loose pieces with FullLight technology go well beyond the minimum UL-required — #18 to#12 AWG terminals—ideal for long runs or existing "cross"pattern. wiring Depending on the model,Genesis horn-strobes feature 15 to 95, • Unparalleled performance or 95 to 177 candela output(see ordering information),which is — Exclusive FullLight strobe technology produces the industry's selectable with a conveniently-located switch on the front of the most even light distribution device.The candela output setting is clearly visible even after final — Single high-efficiency microprocessor controls installation,yet it remains locked in place to prevent unauthorized both horn and strobe movement after installation. — Low current draw minimizes system overhead — Independent horn control provided over a single Genesis hom-strobes feature textured housings in architecturally neu- pair of wires tral white or eye-catching fire alarm red.An ingenious iconographic — Highly regulated in-rush current allows the maximum symbol indicates the purpose of the device.This universal symbol number of strobes on a circuit is code-compliant and is easily recognized by all building occu- — 100 dB peak—multiple frequency tone improves pants regardless of what language they speak.Models with"FIRE" wall penetration markings are also available. Page 1 of 4 U A.r A 5 H E E'T K85001-0559 Not to be:;sed for instalk: .ases. Issues Application Installation and Mounting Genesis strobes are UL 1971-listed for use indoors as ceiling-or All models are intended for indoor wall or ceiling applications wall-mounted public-mode notification appliances for the hearing only.Horn-strobes mount to any flush North-American 4"square impaired.Prevailing codes require strobes to be used where ambi- electrical box. ent noise conditions exceed 105 dBA(87dBA in Canada),where o occupants use hearing protection,and in areas of public accom- modation as defined in the Americans with Disabilities Act(see application notes—USA). O• O O, o• Combination horn-strobe signals must be installed in accordance 0 with guidelines established for strobe devices. Strobes Genesis strobes are UL 1971-listed for use indoors as ceiling-or o wall-mounted public-mode notification appliances for the hearing impaired.Prevailing codes require strobes to be used where ambi- ent noise conditions exceed specified levels,where occupants use hearing protection,and in areas of public accommodation. Genesis ceiling horn-strobes simply unlatch and twist to open. Consult with your Authority Having Jurisdiction for details, This gains access to mounting screws and the selectable candela switch.The shallow depth of Genesis devices leaves ample room All Genesis strobes exceed UL synchronization requirements behind the signal for extra wiring.Once installed with the cover in (within 10 milliseconds other over a two-hour period)when used place,no mounting screws are visible. with a synchronization source. Synchronization is important in order to avoid epileptic sensitivity. Kidde recommends that these fire alarm horn-strobes always be installed in accordance with the latest recognized edition of NOTE:The flash intensity of some visible signals may not be adequate national and local fire alarm codes. to alert or waken occupants in the protected area. Research indicates that the intensity of strobe needed to awaken 90%of sleeping persons is Field Configuration approximately 100 cd.Kidde recommends that strobes in sleeping rooms Depending on the model,Genesis horn-strobes may be set for 15 be rated at at least 110 cd. to 95,or 95 to 177 candela output(see ordering information).The WARNING:These devices will not operate without electrical power.As output setting is changed by simply opening the device and sliding fires frequently cause power interruptions, further safeguards such as the switch to the desired setting.The horn-strobe does not have backup power supplies may be required. to be removed to change the output setting.The setting remains visible through a small window on the front of the device after the cover is closed. Horns The horn-strobe comes factory set for high dB output. Low dB Genesis horn output reaches as high as 99 dB(peak)and output may be selected by cutting a jumper on the circuit board. features a unique multiple frequency tone that results in excel- This reduces the output by about 5 dB. lent wall penetration and an unmistakable warning of danger.All models may be configured for either coded or non-coded signal circuits.They can also be set for low dB output with a jumper cut that reduces horn output by about 5 dB. Wiring The suggested sound pressure level for each signaling zone used Field wiring terminals accommodate#18 to#12 AWG(0.75 mm2 with alert or alarm signals is at least 15 dB above the average ambient to 2.5 mm2)wiring.Horn/strobes are interconnected with a single sound level,or 5 dB above the maximum sound level having a duration pair of wires as shown below. of at least 60 seconds,whichever is greater,measured 5 feet(1.5 m) above the floor.The average ambient sound level is,A-weighted sound Q pressure measured over a 24-hour period. + + To next Doubling the distance from the signal to the ear will theoretically appliance, result in a 6 dB reduction of the received sound pressure level. ala Polarity onown in o°return to alarm condition H H The actual effect depends on the acoustic properties of materials control in the space. A 3 dBA difference represents a barely noticeable _ equipment change in volume. ONote:Strobes must have continuous voltage. Dimensions 6.6'dia. (173 mm) i} p 1 S q (25 mm) 0.60"(15 mm) Paye 2 of 4 {E E r K85001-0559 -14ot:o be used for installa, Issue 1 Current Draw EGC-HDVM Temporal Horn-strobe:High dB Setting EGC-HDVMH High cd Temporal Horn-strobe:High dB Setting UL 15 cd 30 cd 75 cd 95 cd 95 cd 115 cd 150 cd 177 cd Rating _RMS RMS RMS RMS ___RMS RMS RMS RMS 16 Vdc 147 190 316 372 341 399 506 _ 570 16 Vicar 189 253 417 451 487 578 670 711 EGC-HDVM Temporal Horn-strobe:High dB Setting EGC-HDVMH High cd Temporal Horn-strobe:High dB Setting Typical 15 cd 30 cd 75 cd 95 cd 95 cd 115 cd 150 cd 177 cd Current RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean ......_......_......................................................._.........................-.............__......................__..............._............................_.....__.._...............I.......................... ..........................................._.._..............................................._..._......................_..._...._.............-.........-_..._............................................. 16 Vdc 111 95 152 143 281 276 333 328 324 322 377 374 477 474 554 551 - ITT... .. 20 Vdc 91 80 124 117 219 214 257 251 258 256 299 296 369 366 417 414 24 Vdc 80 71 108 101 185 180 212 2_07 220217 252_ _249 304 301 341 338 Vdc 69 62 89 84 144 140 160 -156 172 169 188 185_T3 —223 T 220 244 241 16 Vfwr 153 81 218 123 388 240 420 268 463 265 535 312 665 400 718 442 20 Vfwr 141 70 190_ 100 325 188 378 219 392 211 439 240 517 287 587 334 24 Vfwr 135 64 176 90 280 154 310 180 346 179 382 212 458 246 498 271 ....._......_......_......_..........-..._.-_......__._......_................_.............................._..-................._._.—....—._........................._....... .....................__.._.............................._.............-._--....-_---.--_......................_..._.....-------_._._.................................. 33 Vfwr 139 61 167 80 241 122 254 133 296 142 323 152 358 178 387 194 EGC-HDVM Temporal Horn-strobe:Low dB Setting EGC-HDVMH High cd Temporal Horn-strobe:Low dB Setting Typical 15 cd 30 cd 75 cd 95 cd 95 cd 115 cd 150 cd 177 cd Current RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean RMS Mean .................. — ....--- ...... 16 Vdc 108 91 149 139 275 269 327_ 322 _317 315 378 376 480_ 477 544 542 20 Vdc 87 75 120 113 214 209 250 245 252 250 292 2_90_ 364 362 414 411 ............. 1. _ 24 Vdc 76........... 66 103 ........._.97.... 180 175y___.._205 201 212 _ 211 245 243 297 295- 334 332 - ............_.. _ 33 Vdc 64 57 85 80 138 135 153---150 159 157 181 179 215 213 234 232- 16 Vfwr 141 76 204 118 384 239 418 265 461 265 521 305 656 396 705 432 . .. ......._.._.. _ _ 20 Vfwr 127 65 176 95 312 181 371 214 381 208 437 242 508 285 576 326 11.11.11,11.11 _...._.-.............._......................---..._......_.._. ._._.....................---._......................_.__.._ _._........................_..._._.-. 24 Vfwr 118.................60 _......__1.62 ..........._82................262_._.__.....149 301 171 335 172 370 195 440 235 485 264 33 Vfwr 127 56 155 73 229 118 249 129 285 134 308 149 349 169 373 186 Notes and Comments 1. Current values are shown in mA. 2. UL Nameplate Rating can vary from Typical Current due to measurement methods and instruments used. 3. Kidde recommends using the Typical Current for system design including NAC and Power Supply loading and voltage drop calculations. 4. Use the Vdc RMS current ratings for filtered power supply and battery AH calculations.Use the Vfwr RMS current ratings for unfiltered power supply calculations. 5. Fuses,circuit breakers and other overcurrent protection devices are typically rated for current in RMS values.Most of these devices operate based upon the heating affect of the current Flowing through the device.The RMS current(not the mean current)determines the heating affect and therefore,the trip and hold threshold for those devices. 6. Our industry has used'mean'currents over the years. However,UL will direct the industry to use the 2004 RMS values in the future. dBA output Light output - (effective cd) UL464 Average Peak HighdB .........................................................................._._...........................................-9...........:..._.............._......................... Percent of UL rating versus angle Setting Temporal Steady Temporal! Temporal/ _ _._.._ SteadySteady mo�m a ero m o w s m __79.8 16 Vdc 3.2 as w o so so ro a so 0o m 90.6 93.6 24 Vdc 83.3 1 85.4 93.6 96.6 t r - __,_— 33 Vdc 85 87.8 95.7 _ 98 7 _ �s x '�s a j UL464 Average Peak ., ° Low dB - -sot, so• Setting Temporal Steady Temporal/ Temporal/ \ Steady Steady 16 Vdc 75 79.3 86.3 88.7 �s rr 's' 24 Vdc 78 i 83 88.8 92.4 3; 33 Vdc 80.9 85.9 91.8 95.1 o• Notes 1.All values shown are dBA measured at 10 feet(3.01 m);2 UL464 values measured in reverberation room;3.Average and Peak values are measured in anechoic cham- ber. Page 3 of 4 u A A S H W L K85001-0559 Not to be user'for install-lion pOrpost s, Issue 1 " ^ Specifications Housing Textured LN stabilized,color impregnated engineered plastic.Exceeds 94V- idde Ver K 0 UL flammability rating.Red and white models available. Lens Optical grade polycarbonate(clear) Technology that saves lives Mounting North-American square— --`- - -(54 mm)`----(indoor wall- ceiling applications only). Contact us ,°=°""="""= Screw terminals:single input for both horn and strobe.#18 to#12 AWG(0.75 MM2to 2.5 mm�wire size Email:kidde.fire@fs.utc.com Operating environment Indoor:32-120'F(0-49'C)ambient temperature.93%relative humidity Web: Meets or exceeds ULC-S525&ULC-S526,year 2004 UL mq��me�am,e�n��oUu6�a�uuo� � �a ~ ���umn�� ��� ���p��» � uu�m����m���m�with ADA m—omn — mFederal — 1mo:ormmte Park Drive Regulation Chapter 28 Part 36 Final Rule. MEA.FM pending. Mebane,wox/oo: _____............................. sGC-HovM series temporal-tone horn'mn,bem:non'codmm.xnomo muo10United Technologies ovrpmnm/vn oPvn�i»u~maQo 1s'oavuoo,vrmnoem1o'oovuvpWn kxoouou�vu/u�mAconM � All rights reserved. when u�mvw''' musa mo �� Signal m Strobe output rating u -- '71'--1--'------------'1---7-/95------ novm )--_ EGC-HDVM series temporal-tone oom'mmoes:one flash per second synchronized with optional EG1 MGenesis Signal Master indefinitely Strobe flash rate within 1Omilliseconds(or ooff-oynm � m` ndwithin unomilliseconds over thirty minutes unacommon circuit without sG1MGenesis Signal Master)Temporal setting(private mode only):synchronized to temporal output of homs on same circuit MIRMIRBPS1 OA EGC-HDVM series temporal-tone horn-strobes:temporal rate synchronized with optional Bo1MGenesis Signal Master indefinitely Horn pulse rate within 10milliseconds(or self-synchronized wmmnuoommivoovngu over thirty minutes onacommon circuit without EG1mGenesis Signal Master) Temporal audible pattern 1/2 sec ON,1h sec OFF,1h sec ON,1/2 sec OFF,1/2 sec ON,11/2 sec OFF,then repeat cycle (lnHe[iOg |nfO[Ol8f'On Catalog Housing Ship Marking Description Wt.wvm��, Color _______'________'__-___-�__-V�k__ EGC-HDVM White None oonoo�Camngmvu Horn-Strobe--- -'- '--- F'- wnomuoctau|o1o.00.7o.mesommmpm 0.82 � -__ _.- R-- "FIRE" (1-8) EGC-HDVMH White None Genesis Ceiling/Wall Horn-Strobe EGCF-HDVMH White "FIRE" with selectable 95, 115,150,or 177 cd output Accessories EG1 M-RM Genesis Signal Master—Remote Mount (11-gang) 0.2 GSA-CC1S Intelligent Synchronization Output Module (2-gang) 0.5 GSA-MCClS Intelligent Synchronization Output Module (Plug-in UIO) 0.18 White Field Configurable neilm Hom-Strobes may be ordered wnxmwithout optional'nns'mmm,w.nou Horn-Strobes come With'nns^marking. Page 4m* DATA S*sc . K85001-0559 � <I;;::a...*i;a+.<: ►Strobes,Horns,Bells,Chimes *il%di d. e Technology that saves lives S5389, Field CEMEA .75 Horns and _ . 7125-1501:0121 Strobes 7125.1501:0145 s �� 7125-1501:0162 Genesis Series ECS/MNS appliances available with clear or amber lenses. C E Ai A ALERT; R t Overview Standard Features The Genesis line of fire alarm and mass notification/emergency Unique low-profile design communications(ECS/MNS)signals are among the smallest, — The most compact UL-1971/ULC-S526 listed strobe available most compact audible-visible life safety signaling devices in the — Uftra-slim—protrudes less than one inch world.About the size of a deck of playing cards,these devices are — Attractive appearance designed to blend with any decor. — No visible mounting screws Thanks to patented breakthrough technology,Kidde Genesis Four field-configurable options in one device strobes do not require bulky specular reflectors and lenses. — Select 15,30,75,or 110 cd strobe output Instead,an exclusive cavity design conditions light to produce — Select high(default)or low dB horn output a highly controlled distribution pattern.Significant development — Select temporal(default)or steady horn output efforts employing this new technology have given rise to a new — Select public mode flash rate(default)or private mode benchmark in strobe performance—FullLight technology. temporal flash FullLight strobe technology produces a smooth light distribution Fixed 15/75 cd model available pattern without the spikes and voids characteristic of specular re- ECS/MNS models available flectors.This ensures the entire coverage area receives consistent illumination from the strobe flash.As a result,Genesis strobes with • Easy to install FullLight technology go well beyond the UL-1971 and ULC-S526 — Fits standard 1-gang electrical boxes —no trim plate needed light distribution requirements. — Optional trim plate accommodates oversized openings — Pre-assembled with captive hardware Genesis strobes and horn-strobes offer selectable candela output — #12 AWG terminals—ideal for long runs or existing wiring by means of a conveniently-located switch on the side of the device. Models are also available that offer fixed 15/75 cd output. Unparalleled performance The candela output setting remains clearly visible even after final — Industry's most even light distribution installation,yet it stays locked in place to prevent unauthorized — Meets tough synchronizing standards for strobes tampering. — Single microprocessor controls both horn and strobe — Independent horn control over a single pair of wires Genesis ECS/MNS appliances offer emergency signaling with — Highly regulated in-rush current clear or amber lenses and with optional ALERT housing labels. — Multiple frequency tone improves sound penetration They are ideal for applications that require differentiation between — Field-programmable temporal strobe output option fire alarm and mass notification alerts. Page 1 of 6 D A' A S M W L f K85001-0573 Not to be used'or ostallation aurposae; Issue 1.1 Application Installation Genesis strobes are UL 1971-listed for use indoors as wall-mount- Genesis horns and strobes mount to any standard one-gang sur- ed public-mode notification appliances for the hearing impaired. face or flush electrical box, Matching optional trim plates are used Prevailing codes require strobes to be used where ambient noise to cover oversized openings and can accommodate one-gang, conditions exceed 105 dBA(87dBA in Canada),where occupants two-gang,four-inch square,or octagonal boxes,and European use hearing protection,and in areas of public accommodation 100 mm square. as defined in the Americans with Disabilities Act(see application All Genesis signals come pre-assembled notes—USA). with captive mounting screws for easy in- Combination horn-strobe signals must be installed in accordance stallation.Two tabs at the top of the signal with guidelines established for strobe devices.Consult with your unlock the cover to reveal the mounting Authority Having Jurisdiction for details. hardware.The shallow depth of Genesis All Genesis strobes exceed UL synchronization requirements devices leaves ample room behind the (within 10 milliseconds over a two-hour period)when used with a signal for extra wiring.Once installed with synchronization source. Synchronization is important in order to the cover in place,no mounting screws avoid epileptic sensitivity. are visible. WARNING:These devices will not operate without electrical power.As Field Configuration fires frequently cause power interruptions, further safeguards such as Genesis Horn/Strobe backup power supplies may be required. with optional trim plate Temporal horn and horn-strobe models are factory set to sound in a three-pulse temporal pattern.Units may be con- figured for use with coded systems by cutting a jumper on the Horns circuit board.This results in a steady output that can be turned Genesis horn output reaches as high as 99 dB and features a on and off(coded)as the system applies and removes power to unique multiple frequency tone that results in excellent sound the signal circuit.A Genesis Signal Master is required when horn- penetration and an unmistakable warning of danger.Horns may be strobe models are configured for coded systems. Non-temporal, configured for either coded or non-coded signal circuits.They can horn-only models sound a steady tone. also be set for low dB output with a jumper cut that reduces horn Genesis clear strobes and horn-strobes are shipped from the fac- output by about 5 dB.Hom-only models may be ceiling-mounted tory ready for use as UL 1971 compliant signals for public mode or wall-mounted. operation.These signals may be configured for temporal flash by The suggested sound pressure level for each signaling zone used with cutting a jumper on the circuit board.This battery-saving feature is alarm signals is at least 15 dB above the average ambient sound level, intended for private mode signaling only. or 5 dB above the maximum sound level having a duration of at least Genesis clear strobes and horn-strobes may be set for 15,30,75, 60 seconds,whichever is greater,measured 5 feet(1.5 m)above the or 110 candela output.The output setting is changed by simply floor.The average ambient sound level is,A-weighted sound pressure opening the device and sliding the switch to the desired setting. measured over a 24-hour period. The device does not have to be removed to change the output Doubling the distance from the signal to the ear will theoretically result setting.The setting remains visible through a small window on the in a 6 dB reduction of the received sound pressure level.The actual side of the device after the cover is closed. effect depends on the acoustic properties of materials in the space. Horns and horn-strobes are factory set for high dB output. A 3 dBA difference represents a barely noticeable change in volume. Low dB output may be selected by cutting a jumper on the circuit board.This reduces the output by about 5 dB. ECS/MNS Applications Genesis ECS/MNS strobe appliances bring the same high- performance fire alarm features and unobtrusive design to mass notification applications.Available with amber lenses and optional Wiring ALERT housing labels,they are ideal for applications that require Field wiring terminals accommodate#18 to#12 AWG(0.75 mm2 differentiation between fire alarm and mass notification alerts. to 2.5 mm2)wiring.Horns,strobes,and combination horn-strobes are interconnected with a single pair of wires as shown below. + + To next 4 appliance, Polarity shown in end-of-line alarm condition H H or return to control equipment ONote:Strobes must have continuous voltage. Page 2 of 6 J A rA SHEE , K85001-0573 Not to b� used`or installation purpc Issue 1.1 Current Draw Strobes, Horn-Strobes Horns Multi-cd Wall Strobes(EG1-VM) Wall or Ceiling Mounted UL 15 cd* 30 cd' 15/75 cd** 75 cd* 110 cd* Temporal Horns(EGi-HD) Rating RMS RMS RMS RMSRMS UL High dB Low dB . ,-- _..._. _._......_.....-- .......---....._.._....._......._.._._._..__.....—--............._.. --- --.........._. 16 Vdc 103 141 152 255 311 Rating .(RMS) (RMS) 16 Vfwr _..._i 25_._..._..._ 179-- --224 346 - - 392---- 16 Vdc 26 ! 19 'EGi-VM multi-cd;*'EG1 F-V1575 fixed 15/75 cd 24 Vdc 36 27 33 Vdc 41 j 33 Typical 15 cd 30 cd 15/75 75 cd 110 cd _ 16 Vfwr 51 37 - Current RMS RMS RMS RMS RMS 24 Vfwr 69 52 16 Vdc 85 127 150 245 285 33 Vfwr 76 70 20 Vdc 71 98 123 188 240 _—__...__...__._......_...._.....--------................ . .........................._._..................................._-. 24 Vdc 59 i 82 - -__ 104_ .- 152 -.__. �_ - 191—�_- Typical High dB ! Low dB 33 Vdc 46 64 84 112 137 Current RMS RMS_ _16 Vfwr 119 169 223 332 376 16 Vdc 22 17 _ 20 Vfwr 103143 189 253 331 20 Vdc 24 19 24 Vfwr 94 -......1.29..... _ 169 218_ 262 V 24 Vdc 27 22 33 Vicar 87 112 148 179 205 33 Vdc 32 26 16 Vfwr 34 0 Wall Temporal Horn-strobes-High dB Setting 20 Vfwr 40 34 15 30 115/75 75 110 'EG1-HDVM muni-cd 38 24 Vicar _......45..............,------- _.._ Rating cd* cd* cd** cd* cd* ­EG F-HDV1575 fixed 15/75 cd 33 Vtwr 52 47 RMS RMS , RMS RMS RMS 16 Vdc 129 167 172 281 337 - Wall or Ceiling Mounted Horns(EG1-P) 16 Vfwr 176 230 269 397 443 Max.Current, UL Designation Voltage Range — - ......... ._...._.._._...-—........................................... RS M ........... Typical 15 cd 30 ed15/75 75 cd 110 cd Regulated 24 16 33 Vdc 13 mA Current RMS ! RMS RMS RMS RMS- Vdc _16 Vdc 102 135 160 246 _ 309 24 fwr 16-33 Vfwr 11 mA 20 Vdc 88 109 137 193 248 24 Vdc...............__...-_81 _.... ..._.-......94................_......_...-- 122 ............ ._._._ 161 ._._..._....._.._.... ...203.................... lYPical Curcent _ RMS 33 Vdc 74 72 106 124 154 24 Vdc 10 16 Vfwr 144 1182 247 352393 24 Vdc 11 20 Vfwr 141 1 162 220 274 362 31 Vdc12 _._—.._-......................._.......---.............................._..................._.............._................................ 24 Vfwr 136 152 20_3 235 282 20 Vfwr - 9 _- _.._ _.......... - 24 Vfwr 10 196 _ .._. 201 _.._............._ 232 Wall Temporal Horn-strobes-Low dB Setting Current values are shown in mA. UL 15 30 ' 15/75 75 110 Rating cd* cd* i cd** cd* cd* RMS RMS ; RMS RMS RMS 16 Vdc 122 160 146 274 330 *EGi-HDVMmufti-cd --....._................._....................................,..__.........._.__........... ...... 16 Vfwr 162 216 ! 231 383 429 **EG1 F-HDV1575 fixed 15/75 ed Typical 15 cd 30 cd 15/75 75 cd 110 cd Current RMS RMS RMS RMS RMS 16 Vdc __ 96 130 158 243 302 20 Vdc 79 104 133 189 241 24 Vdc 68 88 119 156 197 33 Vdc 56 71 100 118 146 16 Vfwr 128 180 241 344 389 20 Vfwr 118 157 213 266 343 ----_..........._.I.._._....._.._......_..._.. _ - _ _......................_.... --- ....._........_.... _ 24 Vfwr 113 144 195 230 279 33 Vfwr 1 112137 182 _97-- - — 197 ................................226 .._....- Page 3 of 6 UA-: s H L L K85001-0573 Not to be used r`or nstafla ++ Issue 1.1 dBA output Average Sound Output (dBA) Temporal Horns, Horn-strobes (High dB setting,anechoic,24V,measured at 1 Oft) (EG1-HD,EGi-HDVM series) High I UL464 Average Peak d8 i Temporal/ Temporal/ Temporal Steady Setting.....:._. __.-._......................... - -_.............................Steady._....................._Steady - -75- 6 ;� ,5• s ,S 16 Vdc 81.4 85.5 91.4 94.2 24 Vdc 84.4 88.6 94.5 97.6 33 Vdc 86.3 90.4 96.9 99.5 -._.. ......._.._ V _._................................_.._....._............................... _............. .. . ............................_...._._.................................._._...._-.._ --�-- UL464 Average Peak Low dB ; - — Temporal/ Temporal/ Setting Temporal Steady a ,5• Steady Steady ° 16 Vdc 76.0 80.1 86.3 89.2 24 Vdc ! 79.4 83.5 89.8 92.5 Light output - (effective cd) 33 Vdc 82.1 86.5 1 92.5 95.3 Percent of UL rating versus angle Steady Tone Horns(EG1-P series) UL464 Average Peak ° 16 Vdc j 77 dBA,min 85 dBA91 dBA F - o °°• i 6 Vfwr T 77 dBA,min 85 dBA 91 dBA Notes 1. All values shown are dBA measured at 10 feet(3.01m). 2. UL464 values measured in reverberant room. 3. Average and Peak values are measured in anechoic chamber. .6.; 0^• 00• 0. Specifications Housing Red or white textured UV stabilized,color impregnated engineered plastic.Exceeds 94V-0 UL flammability rating. Lens Optical grade polycarbonate(clear) --.....................__......_-._........_........................._......._....._._.........................__......_.. --_ -- ---...._ ._..............................______.................... .._._.._..............__-._..............----... -----..................._------...._...._................ Strobes and horn-strobes are for wall-mount installation only.Horn-only models may be ceiling-or wall-mounted. Mounting Flush mount:21/2 inch(64 mm)deep one-gang box (indoor only) Surface mount:Model 27193 surface mount box,wiremold box,or equivalent surface-mount box With optional trim plate:One-gang,two-gang,four-inch square,octagonal,or European single-gang box Wire connections Screw terminals:single input for both horn and strobe.#18 to#12 AWG(0.75 mm2 to 2°5 mm�wire size Operating environment Indoor only 32-120°F(0-49°C)ambient temperature.93%relative humidity ----..__......_... ............._.._.....__......_. ........... _ _... __.............._....................._........._._._._._...................._._._�-_._-......._...._---- ...._...._... -._.__.... _...._.................... Agency listings/approvals UL 1971 (S218),UL 1638(S218),UL 464(S218),ULC S525,ULC S526,CSFM,CE,...FCC,MEA. (Al models comply with ADA Code of Federal Regulation Chapter 28 Part_36 Final Rule.) Dimensions(HxWxD) Signal:4-1/2"x 2-3/4"x 13/16"(113 mm x 68 mm x 21 mm) Trimplate: 5"(127 mm);Height-5-7/8"(149 mm);Depth-1/z"(13 mm) EGi-HD series temporal-tone horns:non-coded,filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR(or coded when horn set to steady tone) Operating voltage EGi-HDVM series temporal-tone horn-strobes:non-coded,filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded (audible NAC only)when used with optional EGi M Genesis Signal Master) EGi-VM series strobes:non-coded,filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR EG1-P series steady-tone horns:coded or non-coded,filtered 20-31 Vdc or unfiltered 20-27 Vfwr UL 1971,UL 1638,ULC S526:selectable 15 cd,30 cd,75 cd,or 110 cd output Strobe output rating UL 1971:15 cd(fixed 15/75 cd models) UL 1638,ULCS526:75 cd(fixed 15/75 cd models) EG1-VM strobes and EG1-HDVM series temporal-tone horn-strobes:one flash per second synchronized with optional Strobe flash rate EG1 M Genesis Signal Master indefinitely within 10 milliseconds.Temporal setting(private mode only):synchronized to temporal output of horns on same circuit -.-.............-.... -- _.........._— .................................._-- .................... _ _ .___._.._.—....._......_- ........._........-_ .......—_......... Synchronization Sources FACPs:VM and VS Series life safety systems,FX Series fire alarm control panels.Moduels:GSA-CC1S,GSA-MCCiS, SIGA-CC2A,GSA-MCC2A,EGiM-RM.Power supplies:MIRBPS6A,MIRB_PS10_A,APS6A,APS10A. EGi-HD temporal-tone horns and EGi-HDVM series temporal-tone horn-strobes:temporal rate synchronized with Horn pulse rate optional EGi M Genesis Signal Master indefinitely within 10 milliseconds.EG1-P steady-tone horns:continuous,steady tone only Temporal audible pattern 1/z sec ON,Yz sec OFF,1/2 sec ON,1/2 sec OFF,1/2 sec ON,11/2 sec OFF,then repeat cycle Page 4 of 6 D ATA SHEET K85001-0573 Not to h� used'or ir:staklafion purr-C,; Issue 1.1 Candela Output Fire appliances available with white or red housings. Switch Switch Switch F � F Lens Switch II r Rating Position Position Position ' Color Position A B C p FIRE E ! E Amber UL 1638 110 cd 75 cd 30 cd 15 cd Amber UL 1971' 88 cd 60 cd 24 cd 12 cd -Clear .UL 1971. 1.10 cd 75 cd30 cd........ 15 cd _ ..... ...........-. —......_.._.___...__.._. ............... ........................ ECS/MNS appliances available with clear or amber lenses, Equivalent Rating L L E a T ALERT ir— Ordering Information Model Housing_.1...._Marking Lens Strobe..._.........._.._........... -._..._............__._............_...._.�._Horn.........__...__.......... _...................... Ship Wt-lbs(kg) ... _Fire Alarm Appliances(c/w running man icon screen printed on housing) EG1-VM White None Clear I Selectable 15,30,75,or 110 cd Strobe only 0.25 (0.11) EG1 F-HD White FIRE Clear ; Horn only Selectable high/low dB 0.25 (0.11) EG1F-HDV1575 White FIRE Clear 15/75 cd' Temporal hi/lo dB-24V 0.25 (0.11) FIRE _. _ ............_.. _ ....._.................._...................... -----.._._.—_ —.._.. EG1F-HDVM White Clear I Selectable 15,30,75,or 110 cd Selectable high/low dB 0.25 (0.11) ------ -..._....___.._............................................................................---_........................................_........-- ...--.._.__..__._...._...._._. _...._.._........................ ._._.__......_................................... .---- ...._........._....._._..._. EG1 F P White FIRE Clear 'Steady Horn(not compatible with Genesis Signal Master) 0.25 (0.11) ......................................_.._.._—......_.......... _... .......................-._-...._ -_....- ----...........--...._.....__._.................._......... — EG1F-V1575 White FIRE Clear 1 15/75 cd' Strobe only 0.25 (0.11) EG1F-VM White FIRE Clear I Selectable 15,30,75,or 110 cd Strobe only 0.25 (0.11) EG1-HD White None Clear j Horn only Selectable high/low dB 0.25 (0.11) EG1-HDVM White None Clear Selectable 15,30,75,or 110 cd Selectable high/low dB 0.25 (0.11)_ -........_.. _ _..._.—;. __............... EG1-P White None Clear Steady Horn(riotcompatible with Genesis Signal Master) 0.25 (0.11) _ EG1 RF-HD Red F ----_.........__............................_........ -..............._._E._...._.... —......__.._................_..:....._.__._............................._.._.. _- -..._..._.................. IRClear Horn only Selectable high/low dB 0.25 (0.11) _ --__........................—................. —_.... _T _.�._................. _ __ _ _..-...-..._. �._..._.._.._._ EGi RF-HDV1575 Red FIRE Clear 15/75 cd Temporal hi/lo dB-24V 0.25 (0.11) EG1 RF-HDVM Red FIRE Clear I Selectable 15,30,75,or 110 cd Selectable high/low dB 0.25 (0.11) EG1RF-P Red FIRE Clear Steady Horn(not compatible with Genesis Signal Master) 0.25 (0.11) EG1RF-V1575 Red FIRE Clear 15/75 cd' Strobe only 0.25 (0.11) EG1 RF-VM Red FIRE Clear _......................_......_._............_-....- ----- -...._......_.__....._... Selectable 15,30,75,.. 110 cd Strobe only 0.25 (0.11) EG1R-HD Red None Clear Horn only Selectable high/low dB 0.25 (0.11) —.._.._. .... ......................- —. . -- --......_.._ EG1 R-HDVM Red None Gear _.............._—.... ........................... Selectable 15,30,75,or 110 cd Selectable high/low dB 0.25 (0.11) EG1 R-P Red None Clear Steady Horn(not compatible with Genesis Signal Master) 0.25 (0.11) EG1 R-VM Red None Clear Selectable 15,30,75,or 110 cd Strobe only 0.25 (0.11) ECS/MNS Appliances(no running man icon on housing) G1 WA-VMA White ALERT Amber Selectable A,B,C or D Strobe only 0.25 (0.11) -- --........... _............._... — _......._..__ _—_......._._. --_....................._.............._...__.............................._. _._........................... G1 WA-VMC White ALERT Clear Selectable 15,30,75,or 110 cd Strobe only 0.25 (0.11) G1 WN-VMA White None Amber j Selectable A,B,C or D Strobe only 0.25 (0.11) G1 WN-VMC White None Clear Selectable 15,30,75,or 110 cd Strobe only 0.25 (0.11) Trim Plates ---- -- -- ---- EG1T White None Genesis Trim Plate(for two-gang or 4"square boxes) 0.15(0.7) ------._..............._....----— ....... - --- -- --................._ _.--_...................................._....—__._......._._._....._....---...—_........................._ _.._......................... EG1 RT Red None Genesis Trim Plate(for two-gang or 4"square boxes) 0.15(0.7) ....._.................._._....._._—__..._ .........._............. -- ---....._....- -.............---._—. .............._...........---...._..._............_..._............_ E_G1 T-FIRE White FIRE Genesis Trim Plate(for two-gang or 4"square boxes) 0.15(0.7) EG1 RT-FIRE Red FIRE Genesis Trim Plate(for two-gang or 4"square boxes) 0.15(0.7) G1 WT-ALERT White ALERT Genesis Trim Plate(for two-gang or 4"square boxes) 0.15(0.7) Surface Boxes 27193-16White N/A One-gang surface mount box 1 (0.4) -_........................................... 27193-.11 Red N/A One-gang surface mountbox (0.4) These 15/75 cd models provide fixed output and are not multi-candela devices.The 15 cd output component complies with UL1971,while the 75 cd output component complies with UL 1638. Page 5 of 6 D A rE :,.,L u. { K85001-0573 Not to bf,tised`or installation purl:. Issue 1.1 Kidde Technology that saves lives Contact us... Email: kidde.fireft.utc.com Web: kidde.com/engineeredsystems 1016 Corporate Park Drive Mebane,NC 27302 Kidde is a registered mark in the United States and other countries. ©2018 Walter Kidde Portable Equipment. All rights reserved. Page 6 o16 to A I A S l L E T K85001-0573 iso;to be used'or ivs'allalio, v. Issue 1.1 'm