765 Sabalo Dr. POOL18-0048 dwgs 21/2" WHITE VINYL JOINT STRIP (N/A FOR PAVER DECKS) CONCRETE DECK (OPTIONAL) WITH SLIP RESISTANT TOPPING ON COMPACTED GROUND WITH ALL ORGANIC MATERIAL REMOVED. 4" THK. WITH FIBER MESH, 6" WITH #3 REBAR 3 EA #3 REBAR CONTINUOUS 18" LAP SPLICES AS NECESSARY 3" \ STD. REINF.: #3 REBAR @ 10" O.C. B.W. MIN. COVER 3" (EARTH SIDE), 2" (POOL SIDE). REFER TO STRUCTURAL NOTE #1 FOR ALTERNATE SCHEDULE. WATER LItsE TILE. GLAZED, MIN. 4' i I I TYPICAL WALL F ETURN, OR M VACUUM FITTING, WITH WATER STOP FLANGE LIGHT FIXTURE & NICHE R=6"WHEN H=3'-0" RADIUS INCREASES 6' FOR EACH 1' OF DEPTH < 5'-0" R=2'-0"WHEN FI=5'-0" RADIUS INCREASES V FOR EACH 1' OF DEPTH > V -W QUARTZ AGGREGATE PLASTER FINISH SH(fft l I W WIN 3HE �GUNITE TYPICAL POOL WALL SECTION SCALE: N. T. S. SPA WALL SCHEDULE DEPTH OF CONCRETE WATER FT THICKNESS BEND DOWN INCHES 3.0 6 3.5 6 4.0 6 4.5 10 5.0 10 VERTICAL REINFORCEMENT #3 - 10 INCH CENTERS. NOTE: GREATER WALL THICKNESS M OR DOUBLE CURTAIN REINFORCEMENT MAY BE USED IF REQUIRED FOR AESTHETICS OR PLUMBING 2 - #3 BARS (OR 1 - #4 BAR) HORIZ. REIN. #3 BARS 8- I O.C. FOR FREE STANDING s WALLS VERT. REINF. SEE SPA WALL SCH. SPA DETAIL N.T.S. SEE SPA WALL SCH. .I FSEE STRUCTURAL NOTE 15 TYPICAL REINF. 10" O.C_ E.W. � z FLOOR REINF. CONT. FROM SPA TO POOL MIN. 15' LAP EITHER DIRECTION 2 - #3 EACH WAY z N LIGHT NICHE DETAIL N. T. S. 10" MIN. 3" MIN. (TYP.) EXPANSION JOINT- 8' - 11' a DECK SLAB VINYLZ DECK SLAB 6 Z TILE W,I� --� Fo SEE STRUCTURAL NOTE 15 ' BOND BEAM REIN. 343 I ALTERNATE LOCATION OF BARS (TYP. FOR ALL BOND BEAM BAR (TYP) ( o BOND BEAMS) CANTILEVER DECK DETAIL COPING DETAIL N.T.S. N.T.S. WATER 12 ALTERNATE TROUGH PLUMBING LOCATION AT GRADE �I AT GRADE � � I WATER ' OR ELEVATED TROUGH I�I OR 1� in I� SHEER DESCENT DETAIL N.T.S. PLANS EXPIRE: PLANS VALID FOR THIS BUILDING DEPT. ONLY: MARCH 19, 2019 CIN OF ATLANTIC BEACH Ttw RESIDENTIAL Ce'77teof Autfw4No. 28177 STRUCTURAL DETAILS 4337 PABLO OAKS COURT, SURE 101 IAC �lv 3t773L 992,36 .mo`'`o,``` `�o••• • • • ••.j�t' ' THE BATTS COMPANY '• v CPC037046 - CGC055163 IQ 1714 1602 NORTH 3RD STREET * JACKSONVILLE BEACH, FL 32250 (904) 246-2455 (904) 249-0457 4. i • P♦ • DWG. BY: MAC -.,®�F• ••. RID . ' �� NOT TO SCALE SHEET 2 OF 5 APPROVED BY: ,EL 6' EXPANSION JOINT DECK SLAB 2 - #3-� — — BEND DOWN BOND BEAM BARS io #3 BAR BEND ' I AS SHOWN — _ i F-5--] 343 I o MINIMAL BOND BEAM SKIMMER DETAIL N.T.S. N.T.S. NOTE: MAYBE USED WITH SAND, GRAVEL, OR ROCK SOIL CONDITIONS ONLY. WATER 12 ALTERNATE TROUGH PLUMBING LOCATION AT GRADE �I AT GRADE � � I WATER ' OR ELEVATED TROUGH I�I OR 1� in I� SHEER DESCENT DETAIL N.T.S. PLANS EXPIRE: PLANS VALID FOR THIS BUILDING DEPT. ONLY: MARCH 19, 2019 CIN OF ATLANTIC BEACH Ttw RESIDENTIAL Ce'77teof Autfw4No. 28177 STRUCTURAL DETAILS 4337 PABLO OAKS COURT, SURE 101 IAC �lv 3t773L 992,36 .mo`'`o,``` `�o••• • • • ••.j�t' ' THE BATTS COMPANY '• v CPC037046 - CGC055163 IQ 1714 1602 NORTH 3RD STREET * JACKSONVILLE BEACH, FL 32250 (904) 246-2455 (904) 249-0457 4. i • P♦ • DWG. BY: MAC -.,®�F• ••. RID . ' �� NOT TO SCALE SHEET 2 OF 5 APPROVED BY: ,EL 3'0" MIN. (EDGE OF OUTLET) 3'0" MIN. (EDGE OF OUTLET) 3'0' MIN. (EDGE OF OUTLET) OUTLETS IN PARALLEL TO ONE PUMP OUTLETS IN PARALLEL TO DUAL PARALLEL OUTLETS TO TWO PUMPS PUMPS IN PARALLf1 NOTES: 1. DUAL OUTLETS SHALL BE SEPARATED BY MINIMUM 3 FEET FROM OUTSIDE EDGE TO OUTSIDE EDGE OF OUTLET. 2. TEE ON THE SUCTION MANIFOLD SERVING THE OUTLETS SHALL BE LOCATISD MIDWAY BETWEEN THE OUTLETS WITH FLOW OUT OF THE BRANCH OF THE TEE. 3. THE FLOW RATING OF EACH COVER/GRATE SHALL BE AT LEAST EQUAL TO THE SYSTEM'S MAXIMUM FLOW RATE. 4. OUTLETS MAY BE LOCATED ON SEPARATE PLANES IN LIEU OF THE 3'0" SEPARATION REQUIREMENT, I.E.ONE (1) ON THE BOTTOM AND ONE (1) ON THE VERTICAL WALL, OR ONE (1) EACH ON TWO (2) SEPARATE VERTICAL WALLS. DUAL SUCTION OUTLET" ARRANGEMENTS 3'0- MIN. (EDGE OF OUTLET) 3'0' MIN. (EDGE OF OUTLET) VELOCITY =6FT/S JOFil COP SCH 40 SCH 80 SUCTION PIPE MAX FLOW MAX FLOW DIAMETER (GPM) (GPM) SINGLE UNBLOCKABLE CHANNEL OUTLET TO SINGLE PUMP 2" 63 55 2 112" 90 79 3" 138 124 4- 238 215 6" 540 4867 3'0' MIN. (EDGE OF OUTLET) OUTLETS IN PARALLEL OUTLETS IN PARALLEL SYMMETRIC PIPING ECCE=NTRICALLY TAPPED PIPING OUTLETS IN PARALLEL LOOPED PIPING NOTES: 1. THE OUTERMOST OUTLETS SHALL BE SEPARATED BY MINIMUM 3 FEET FROM OUTSIDE EDGE TO OUTSIDE EDGE OF OUTLET. 2. TEE ON THE SUCTION MANIFOLD SERVING THE OUTLETS SHALL BE LOCATED MIDWAY BETWEEN TWO OF THE OUTLETS WITH FLOW OUT OF THE BRANCH OF THE TEE. 3. THE SUM OF THE FLOW RATINGS OF THE COVERS/GRATES SHALL BE A7 LEAST TWICE THE SYSTEM'S MAXIMUM FLOW RATE. THREE -OR -MORE ;RUCTION OUTLET ARRANGEMENTS NOTES: 1. ALL COVERS/GRATES SHALL COMPLY WITH ANSI/ASME Al 12.19.8 -LATEST, 'SUCTION FITTINGS FOR USE IN SWIMMING POOLS, WADING POOLS, SPAS AND HOT TUBS.' RECOMMENDED: GRATES SHOULD BE INSTALLED WITH SUFFICIENT OPEN AREA TO ENSURE A MAXIMUM VELOCITY OF 1.5 FT/S THROUGH Ti -IE GRATE(S). 2. SUCTION OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH ANSUAPSP-7, LATEST. THIE FOLLOWING METHODS TO AVOID ENTRAPMENT ARE IN ACCORDANCE WITH ANSUAPSP-7: A) SURFACESKIMMING OR OVERFLOW SYSTEMS THAT PROVIDE 100% OF THE REQUIRED SYSTEM FLOW; B) DUAL SUCTION OUTLET SYSTEMS; C) THREE -OR -MORE SUCTION OUTLET SYSTEMS; D) SINGLE UNBLOCKABLE SUCTION OUTLET SYSTEMS; E) SINGLE OUTLET SWIM JET SYSTEMS (TESTED AND LISTED AS CONFORMING 1.0 ASME/ANSI Al 12.19.8); F) SINGLE OUTLET - ALTERNATIVE SYSTEMS (IN ACCORDANCE WITH ANSUASME Al 12.1 9.8 -LATEST AND ASTM F2387-04); G) GRAVITY FLOW TO A VENTED COLLECTOR TANK H) OUTLET SUMPS IN SERIES; 1) OR OTHER MEANS THAT MEET THE INTENTS AND REQUIREMENTS OF ANSUAPSP-7 AND IS APPROVED BY THE AUTHORITY HAVING JURISDICTION. 3. BRANCH SUCTION PIPING (DEFINED AS THE PIPING SERVING THE SUCTION OUTLETS) SHALL BE SIZED TO ALLOW MAXIMUM VELOCITY OF SIX (6) FEET PER SECOND WHEN ONE OF A PAIR IS BLOCKED. ALL OTHER SUCTION PIPING SHALL BE SIZED TO ALLOW MAXIMUM VELOCITY OF EIGHT (8) FEET PER SECOND. 4. POOLS OR SPAS SHALL NOT BE OPERATED IF SUCTION OUTLET GRATE IS MISSING, BROKEN, OR LOOSE. 5. SUCTION INLETS SHALL BE PLUMBED SUCH THAT WATER IS DRAWN THROUGH THEM SIMULTANEOUSLY THROUGH A COMMON LINE TO THE PUMP. 6. SUCTION OUTLET PORT MUST BE SAME DIAMETER OR LARGER THAN SUCTION PIPE EXITING OUTLET. 7. FIELD BUILT SUMPS SHALL BE CONSTRUCTED SUCH THAT THE OPENING OF THE SUCTION PIPE WILL BE NO CLOSER THAN 1.5 TIMES ITS INSIDE DIAMETER FROM THE BOTTOM OF THE COVER/GRATE I)R SUCH THAT THE SUMP IS OF THE DESIGN SPECIFIED BY THE COVER/GRATE MANUFACTURER TO CONTROL I -LOW THROUGH THE OPEN AREA OF THE COVER/GRATE. CIRCULATION LINE TO LEAF CANISTER / RECIRCULATION PUMP NOTE: SEE NOTE 1 BELOW SINGLE UNBLOCKABLE CHANNEL OUTLET TO TWO PUMPS ANY SHAPE 4—owl LARGE UNBLOCKABLE OUTLET OF ANY SHAPE TO SINGLE PUMP NOTES: 1. SINGLE CHANNEL OUTLET: 3" OR GREATER IN WIDTH AND 31- OR GREATER IN LENGTH (APPLIES TO PERFORATED AREA). 2. SINGLE UNBLOCKABLE OUTLET: SHALL BE OF ANY SIZE AND SHAPE SUCH THAT A REPRESENTATION OF THE TORSO OF THE 99TH PERCENTILE ADULT MALE CANNOT SUFFICIENTLY BLOCK IT TO THE EXTENT THAT IT CREATES A BODY SUCTION ENTRAPMENT HAZARD. THE TORSO IS REPRESENTED AS A RECTANGLE 18' X 23' WITH CORNERS OF RADIUS 4'. SINGLE UNBLOCKABLE SUCTION OUTLET ARRANGEMENTS SUCTION OUTLET DEBRIS OUTLET MOUNTED IN POOL FLOOR MINIMUM PIPE LENGTH 18" 2. 90' BEND (TYP. 2" TEE OF 2) 12" AIR GAP (MIN.) MAXIMUM UNDERWATER�� LENGTH OF VENT PIPING: 30 FEET FROM TEE ON Z VENT SUCTION PIPING TO AIR GAP PIPING 1. ONE OF THE FOLLOWING OPTIONS IS REQUIRED BETWEEN THE DEBRIS SUCTION OUTLET AND THE PUMP: A) ONE (1) ADDITIONAL SUCTION OUTLET WITH A LISTED COVER/GRATE LOCATED A MINIMUM OF 18" FROM THE TEE IN THE SUCTION LINE TO THE PUMP(S); B) AN ENGINEERED VENT SYSTEM; C) A LISTED MANUFACTURED SAFETY VACUUM RELEASE SYSTEM. OUTLET SUMPS IN SERIES -SCREEN VENT TO PROHIBIT INSECT ENTRY OR CLOGGING. TO SUCTION PIPING i LABEL VENT AS FOLLOWS: "POOL SAFETY DEVICE - DO NOT HANDLE" VENT LINE DETAIL PLANS EXPIRE: PANS VALID FOR THIS BUILDING DEPT. ONLY: MARCH 19, 2019 I CITY OF ATLANTIC BEACH !!�Qqgt RESIDENTIAL SUCTION OUTLET NOTES Certificate of Authority No. 28mqo177 4337����„jC�OUR;,SUITE101 it _?7� AND DETAILS J,P� 1"" ��236 r. 4k.. . '' •' CEN •°•° ��'��� THE BATTS COMPANY •o ; 5 714 CPC037046 - CGCO55163 a 1602 NORTH 3RD STREET JACKSONVILLE BEACH, FL 32250 -� T (904) 246-2455 (904) 249-0457 •, • t< . ^- 1D • � � ''.e��(Cs�••• Ss+eAJti• DWG. BY: MAC NOT TO SCALE SHEET 3 OF 5 APPROVED BY JEL 1 s #3 BAR CONTINUOUS 4" CONCRETE DECK 1 #3 BAR VERTICALLY @ 36" ON CENTER e COMPACTED w o MK fLATTER .- � i H 1#5REBAR CONTINUOUS I I I A 1 FINISHED GRADE iv 4" 0 PILASTER EVERY, L OLD GROUND 5' WITH 1 #3 REBAR CONCRETE DECK TURNDOWN GRADE Iill%IIN IIII%illl\ 1111% 1111 NO FOOTER PAVER BRICK COMPACTED �. MATERIAL O, 1 #5 REBAR CONTINUOUS.: 4"0 PILASTER EVERY 5' WITH 1 #3 REBAR #3 BAR CONTINUOUS 1 #3 BAR 8" VERTICALLY @ 36" ON CENTER 4.OR FINISHED GRADE OLD GROUND PAVER DECK TURNDOWN PAVER BRICK SWALE FOR DRAINAGE � 8, `v N .d COMPACTED MATERIAL ' d NOTE 1 #5 REBAR iv B Y x A ' ` CONTINUOUS ALTERNATE PAVERS ON TURNDOWN 1 #3 BAR VERTICALLY @ 36* ON CENTER N Q N m NOTE: B-)4"xA ALTERNATE PAVER LOCATION GENERAL NOTES 1. DETAIL IS BASED ON NO SURCHARGE BEHIND THE TURNDOWN AND GROUND AWAY FROM TURNDOWN IS LEVEL (>4 TO 8. A DECK TURNDOWN IS NOT INTENDED TO BE A SUBSTITUTE FOR A RETAINING WALL. IF THE VERTICAL DIDIMENSION 1). TURNDOWN MAY ABUT RIBBON FOOTER AND BE TIED INTO FOOTER IF APPROPRIATE, WITH #3 REBAR. FROM THE TOP OF THE CONCRETE DECK TO THE OLD GROUND REACHES 22.5- (FOR A 12- TURNDOWN) OR 33- (FOR AN 2. TURNDOWN SHALL BEAFJ ON ROCK, CLEAN SAND OR STRUCTURALLY SOUND SOIL (> 1,500 PSF) THAT SHALL BE 18" TURNDOWN) OR 43.5" (FOR A 24' TURNDOWN) FOR MORE THAN 2091. OF THE TURNDOWN LENGTH OR THE FINISHED COMPACTED TO PROVIDE OPTIMUM BEARING CAPACITY AND PREVENT SETTLING OR SHIFTING. GRADE SLOPE EXCEEDS 4 FEET HORIZONTALLY TO 1 FOOT VERTICALLY, A TURNDOWN SHOULD NOT BE USED. 3. ALL REINFORCING STEEI. IS TO CONFORM TO ASTM 615 GRADE 40. 9. FOR A PAVER DECK, IF THE VERTICAL DIMENSION FROM THE TOP OF THE DECK TO THE OLD GROUND REACHES Nr (FOR 4. CONCRETE SHALL CONTAIN FIBER MESH AND HAVE A 28 DAY STRENGTH OF 2,500 PSI, A 12- TURNDOWN) 36" (FOR AN 18" TURNDOWN) OR 42- (FOR A 24" TURNDOWN) FOR MORE THAN 20% OF THE TURNDOWN 5. ALL CONSTRUCTION TO CONFORM TO FLORIDA BUILDING CODE, BUILDING 2017, FLORIDA BUILDING CODE, RESIDENTIAL LENGTH OR IF THE FINISHED GRADE SLOPE EXCEEDS 4 FEET HORIZONTALLY TO 1 FOOT VERTICALLY, A TURNDOWN 2017 TOGETHER WITH LATEST REVISIONS. SHOULD NOT BE USED. 6. REFER TO CONTRACTOR'S PLAN ON FILE WITH THE BUILDING DEPARTMENT FOR DETAILS ON TURNDOWN LOCATION. 10. IF A SCREEN ENCLOSURE IS TO BE INSTALLED ON TO OF THE TURNDOWN, THE SWIMMING POOL CONTRACTOR MUST T IF THE TURNDOWN DOES NOT EXTEND INTO THE OLD GROUND, A 4. 0 PILASTER WILL BE REQUIRED EVERY 5 FEET SHAT COORDINATE ATTACHMENT OF THE SCREEN ENCLOSURE TO THE TURNDOWN WITH THE SCREEN CONTRACTOR. WILL BE EITHER 2 FEET IIVTO THE GROUND OR TO 6- INTO THE INDIGENOUS MATERIAL, WHICHEVER IS DEEPER. THE PILASTER WILL HAVE A #3 REBAR TIED INTO THE #5 REBAR IN THE BASE OF THE VERTICAL POUR DECK TURNDOWNS Iill� IIII\1111%1111 IIII\Ilil%1111\ CONTINUOUS ifll%fill\IIIIIIII IIII%IIII\ 1111%NI1=1111 ISM1111illilm 1-11 NII%IIII\ IIII%IIA 8" x 12" FOOTER PLANS EXPIRE: MARCH 19, 2019 FOOTER NOTES: GRADE 1r 1. FOOTER SHALL BEAR ON ROCK, CLEAN SAND OR STRUCTURALLY SOUND SOIL law (>1,500 PSI) THAT SHALL BE COMPACTED TO PROVIDE OPTIMUM BEARING Certificate of Auttmrity No. 28177 2. CAPACITY TO PREVENT SETTLING. CONCRETE SHALL HAVE A 28 DAY STRENGTH OF 2,500 PSI WITH FIBER MESH 4337 6pBL�P1tyA1l�Lt0►/ji�� SURE 103 1 3 Q ````,` 3. 3O#3 BARS EQUIVALENT TO 1 #5 BAR. CONTINUOUS ��G E NS 4. AN ALTERNATIVE TO A CONCRETE DECK IS BRICK PAVERS PLACED EITHER • `o OVER THE TOP OF THE FOOTER OR ABUTTING THE FOOTER. 5. IF A SCREEN ENCLOSURE IS TO BE INSTALLED, THE SWIMMING POOL 12"x 12" FOOTER �, 7 4 CONTRACTOR MUST COORDINATE CONSTRUCTION OF ANY REQUIRED FOOTER WITH THE SCREEN CONTRACTOR. e �o �T T �. TYPICAL FOOTER DETAILS �� �:P\.���`' �.� ..• R I • m PLANS VALID FOR THIS BUILDING DEPT. ONLY: CITY OF ATLANTIC BEACH RESIDENTIAL FOOTER DETAILS THE BATTS COMPANY CPC037046 - CGC055163 1602 NORTH 3RD STREET JACKSONVILLE BEACH, FL 32250 (904) 246-2455 (904) 249-0457 DWG. BY: MAO NOT TO SCALE SHEET 4 OF 5 APPROVED BY:SEL 0 b TRANSFORMER REQUIRED FOR LOW -VOLTAGE INSTALLATIONS ONLY u .` .1 1 1 1 300 WATT 1 REFER TO UNDERWATER NOTE N. FROM INSIDE WALL LIGHT fT I i I I 1 � BONDING CONDUCTOR. i REFER TO NOTE #7 I 1 1I 1 / BONDING GRID. REFER TO NOTE #6 TYPICAL SWIMMING POOL BONDING GRID PLAN PUMP MOTOR I IMCVLI TO SERVICE PANEL JUNCTION' SPST SOX ( TOGGLE SW ITCH 4' MIN. 1 I DISCONNECT PUMP SERVICE PANEL 3 NEUTRAL BAF. TO GRCUND GROUNDBAR BAR TRANSFORMER ENERGY E1 FICIENCY NOTES: 1. TIMF SWITCHES SHALL BE INSTALLED TO CONTROL SWIMMING POOL HEATERS AND PUMPS THAT CAN AUTOMATICALLY TURN THE HEATERS AND PUMPS OFF AND ON ACC' )RDING TO A PRESET SCHEDULE. EXCEPTIONS: 1 a WHERE PUBLIC HEALTH STANDARDS REQUIRE 24-HOUR PUMP OPERATION 1.b. WHERE PUMPS ARE REQUIRED TO OPERATE SOLAR- AND WASTE -HEAT RECOVERY rOOLSYSTEMS 1 c WHERE PUMPS ARE POWERED EXCLUSIVELY FROM ONSITE RENEWABLE rENERATiON 2 HEALED SWIMMING POOLS AND INGROUND PERMANENTLY INSTALLED SPAS SHALL BE EQUirPED WITH A VAPOR -RETARDANT COVER ON OR AT THE WATER SURFACE OR A LIQU11) COVER OR OTHER MEANS PROVEN TO REDUCE HEAT LOSS. EXCEPTION: OUTDOOR POOLS DERIVING OVER 70% OF THE ENERGY FOR HEATING FROM A SITE NECOVERED ENERGY OR SOLAR ENERGY SOURCE COMPUTED OVER AN OPEItATING SEASON. 3 pOOI FILTRATION PUMP MOTORS SHALL MEET THE FOLLOWING REQUIREMENTS: 3.a. POOL PUMP MOTORS SHALL NOT BE SPLIT -PHASE, SHADED POLE OR CAPACITOR S TART INDUCTION RUN TYPES 3.b. POOL PUMPS AND POOL PUMP MOTORS WITH A TOTAL HORSEPOWER (HP) OF GREATER THAN OR EQUAL TO 1 HP SHALL HAVE THE CAPABILITY OF OPERATING AT TWO OR MORE SPEEDS. THE LOW SPEED SHALL HAVE A ROTATION RATE OF NO MORE THAN j OF THE MOTOR'S MAXIMUM ROTATION RATE, 3.c_ POOL PUMPS MOTOR CONTROLS SHALL HAVE THE CAPABILITY OF OPERATING THE POOL PUMP AT A MINIMUM OF TWO SPEEDS. THE DEFAULT CIRCULATION SPEED :HALL BE THE RESIDENTIAL FILTRATION SPEED WITH A HIGHER SPEED OVERRIDE (,APABILITY FOR A TEMPORARY PERIOD NOT TO EXCEED ONE NORMAL CYCLE OR 24 HOURS, WHICHEVER IS LESS. EXCEPTION: SOLAR POOL HEATING SYSTEMS SHALL BE PERMITTED TO RUN AT HIGHER SPEEDS DURING PERIODS OF USABLE SOLAR HEAT GAIN, 4. HYDPAULIC SYSTEMS FOR NEW POOLS MUST BE DESIGNED IN ACCORDANCE WITH APSP 15, 'AMERICAN NATIONAL STANDARD FOR RESIDENTIAL SWIMMING POOL AND SPA F NERGY EFFICIENCY." TO GROUND FAULT CIRCUIT INTERRUPTER THEN TO POWER SOURCE WITH TRANSFORMER 4' MIN. JUNCTION BOX RIGID, IMC OR NON METALLIC CONDUIT �z BRASS OR NON METALLIC CONDUIT OR APPROVED EQUIVALENT z 300 WATT UNDERWATER LIGHTS SHALL BE NEC. APPROVED AND SHALL FEATURE STAINLESS STEEL m FORMING SHELL WITH BRASS MOUNTING RING. SHELL SHALL HAVE A 1' NPT CONDUIT WITH OPENING PACKING GLAND. LIGHT SHALL BE HOUSED IN A STAINLESS STEEL ENCAPSULATION BOLTED TO A CHROME PLATED FACE RING FOR COMPRESSING OF A 360° DOUBLE WALL SYNTHETIC GASKET. SS LIGHT FIXTURE 4 NICHE W/ COMPRESSION HUB & 300W.12V LAMP OR 120 VAC W/ GFCI PER NEC LADDER, HAND RAIL, T DIVING BOARD, ETC... POOL LIGHT POOL METAL CONDUITS REINFORCING OR PIPING SYSTEM STEEL FLEXIBLE CORD GROUNDING TERMINAL H -N -G #8 BOND TO #8 BONG TO STRUCTURAL STEEL STRUCTURAL GROUND BAR #8 BOND D STEEL PVC CONDULI CONTROL PANEL TYPICAL GROUNDING SCHEMATIC ELECTRICAL NOTES: 1. GROUND AND BOND ALL POOLS AND RELATED EQUIPMENT IN ACCORDANCE WITH NEC ARTICLES 250 AND 680. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR TO ENSURE THAT ALL METALLIC PARTS OF THE POOL. STRUCTURE, INCLUDING THE POOL SHELL AND DECK REINFORCING BARS AND ALL OTHER METAL PARTS ARE BONDED PER NEC ARTICLE 250 AND 680. BOND TOGETHER REINFORCING BARS USING STEEL TIE WIRES. BOND ALL METAL PARTS TO POOL REINFORCING BARS USING #8 AWG COPPER WIRES. THESE METAL PARTS INCLUDE, BUT ARE NOT LIMITED TO LADDERS, RAILINGS, PIPING, CONDUIT, METAL DOOR FRAMES AND METAL PARTS WITHIN F OF INSIDE WALL OF POOL. CONNECTION SHALL BE EXOTHERMIC WELD, LISTED PRESSURE CONNECTORS OR CLAMPS AS APPLICABLE. GROUND STEEL COLUMNS (I.E. FOR TOWERS OR SLIDES) PER NEC ARTICLE 250 AND 680 AND NFPA 780. IF REINFORCING BARS ARE ENCAPSULATED WITH A NON CONDUCTIVE COMPOUND, CONTACT ENGINEER BEFORE PROCEEDING. 2. THIS ELECTRICAL INSTALLATION SHALL MEET ALL REQUIREMENTS OF NEC ARTICLES 250 AND 680. IN ACCORDANCE WITH THIS, UNDERGROUND WIRING SHALL NOT BE PERMITTED UNDER THE POOL OR WITHIN F HORIZONTALLY FROM THE INSIDE WALL OF THE POOL UNLESS THIS WIRING IS NECESSARY TO SUPPLY POOL EQUIPMENT PERMITTED BY NEC ARTICLE 680. ALL RECEPTACLES SHALL BE LOCATED AT LEAST 19 FROM THE INSIDE WALL OF POOLS. ALL RECEPTACLES WITHIN 20' OF THE POOL SHALL HAVE GFCI PROTECTION. ADDITIONALLY, ALL UNDERWATER LIGHTING SHALL BE GFCI PROTECTED. MOUNTING HEIGHT FOR ANY LIGHT FIXTURES SUSPENDED OVER POOLS SHALL BE NOT LESS THAN 12' ABOVE MAXIMUM WATER LEVEL. 3. IF APPLICABLE, PROVIDE #12 AWG CONDUCTORS AND GROUND FOR 12V UNDERWATER LIGHTING CIRCUITS LESS THAN 81N LENGTH. FOR 12V CIRCUITS 8' TO 15' IN LENGTH, PROVIDE #8 AWG CONDUCTORS AND GROUND. FOR 12V CIRCUITS GREATER THAN 16, BUT LESS THAN 25' LN LENGTH, PROVIDE #6 AWG CONDUCTORS AND #6 GROUND. NO 12V CIRCUIT SHALL BE MORE THAN 25' IN LENGTH. 4. OPTIONAL: ELECTRICAL CONTRACTOR SHALL INSTALL NO FEWER THAN ONE 125 -VOLT 15 - OR 20 -AMPERE RECEPTACLE ON A GENERAL PURPOSE BRANCH CIRCUIT. RECEPTACLE SHALL BE LOCATED NOT LESS THAN 10 FT. FROM AND NOT MORE THAN 20 FT, FROM THE INSIDE WALL OF THE POOL. THE RECEPTACLE SHALL BE LOCATED NOT MORE THAN 6 FT. 61N. ABOVE THE FLOOR, PLATFORM, OR GRADE LEVEL SERVING THE POOL. 5. RECIRCULATION PUMP SHALL BE ELECTRICALLY INTERLOCKED WITH CHEMICAL EQUIPMENT, IF APPLICABLE. 6. AN EQUIPOTENTIAL COMMON BONDING GRID IS REQUIRED FOR ALL PAVED WALKING SURFACES WITHIN THREE FEET OF THE INSIDE WALLS OF THE POOL AND/OR SPA FOR THE ENTIRE POOL PERIMETER. THE BONDING GRID MAY BE COMPOSED OF STEEL REINFORCING RODS (REBAR), OR #8 BARE, SOLID COPPER CONDUCTORS. 6 X 6 X 10 WELDED WIRE FABRIC (MESH) IS ACCEPTABLE WHEN PROPERLY INSTALLED ON CHAIRS AND EACH SECTION IS CLAMPED WITH APPROPRIATE LISTED DEVICES AND/OR #8 SOLID COPPER JUMPERS. THE BONDING GRID MAY NOT BE INSTALLED DIRECTLY IN EARTH CONTACT OR WITHOUT PROPER COVER. THE INSTALLATION MUST BE IN ACCORDANCE WITH 680.26(C), NATIONAL ELECTRIC CODE (NEC - LATEST VERSION) AND FLORIDA BUILDING CODE (FBC - LATEST VERSION) W/ LATEST AMENDMENTS. T THE FOLLOWING IS AN ACCEPTABLE ALTERNATIVE TO THE BONDING GRID DEFINED IN NOTE #6, ABOVE: AN UNDERGROUND BONDING CONDUCTOR MADE OF A SINGLE #8 AWG BARE SOLID COPPER WIRE BURIED TO A MINIMUM DEPTH OF 4 INCHES TO 61NCHES BELOW SUBGRADE AND 18 INCHES TO 24 INCHES FROM INSIDE WALL OF THE SWIMMING POOL OR SPA. THIS IS DEFINED A PERMISSIBLE ALTERNATIVE OR EQUIVALENT TO COMPLIANCE WITH S.680.26(C) OF THE NEC (2017), NFPA 20, ADOPTED BY REFERENCE WITHIN FBC. #8 AWG PRESSURE GROUND—/ v PLANS VALID FOR THIS CONNECTOR G WITH EI COMMON PLANS EXPIRE. BONDINSTEELORPLUMBING BUILDING DEPT. ONLY. STEEL OR PLUMBING POOL LIGHT DETAIL MARCH 19, 2019 JUNCTION BOX (IF USED) RANORMER CITY OF ATLANTIC BEACH SF POOL LIGHT HEATER CASE DQ" RESIDENTIAL CONTROL�%ELECTRICAL NOTES PANEL Certificate of Authority No. 28177 =1N g 4A3CKSPABLO�O�URT, S `ITE 101 AND DETAILS e• CE •• �F'�,= THE BATTS COMPANY PUMP MOTOR • : ' `�� CPC037046 - CGCO55163 e a 14 1602 NORTH 3RD STREET JACKSONVILLE BEACH, FL 32250 * ! (904)246-2455(904)249-0457 `O 9rF TYPICAL BONDING SCHEMATIC* =-� Q ' 44 •°ems', RI D P•®V�/;a DWG. BY: MAC \\ ``` NOT TO SCALE SHEET 5 OF 5 APPROVED BY: JEL� - L 12 V TRANS. 1. ALL ELECTRICAL SHALL CONFORM WITH ART 680 NEC - 3 012 IN Y2' COND. LATEST 2. BOND ALL SHEATHED CABLES, RACEWAYS. METAL PIPING 12V/ 30OW WITH LOW WATER AND ALL FIXED METAL PARTS NOT SEPARATED BY CUT-OFF OR 120 VAC W/ GFCI PERMANENT BARRIER, IF WITHIN 5 FT HORIZONTALLY FROM PER NEC WATER, 12 FT VERTICALLY OF MAX WATER LEVEL. ELECTRICAL DIAGRAM --INCOMING POWER SUPPLY SERVICE PANEL 3 NEUTRAL BAF. TO GRCUND GROUNDBAR BAR TRANSFORMER ENERGY E1 FICIENCY NOTES: 1. TIMF SWITCHES SHALL BE INSTALLED TO CONTROL SWIMMING POOL HEATERS AND PUMPS THAT CAN AUTOMATICALLY TURN THE HEATERS AND PUMPS OFF AND ON ACC' )RDING TO A PRESET SCHEDULE. EXCEPTIONS: 1 a WHERE PUBLIC HEALTH STANDARDS REQUIRE 24-HOUR PUMP OPERATION 1.b. WHERE PUMPS ARE REQUIRED TO OPERATE SOLAR- AND WASTE -HEAT RECOVERY rOOLSYSTEMS 1 c WHERE PUMPS ARE POWERED EXCLUSIVELY FROM ONSITE RENEWABLE rENERATiON 2 HEALED SWIMMING POOLS AND INGROUND PERMANENTLY INSTALLED SPAS SHALL BE EQUirPED WITH A VAPOR -RETARDANT COVER ON OR AT THE WATER SURFACE OR A LIQU11) COVER OR OTHER MEANS PROVEN TO REDUCE HEAT LOSS. EXCEPTION: OUTDOOR POOLS DERIVING OVER 70% OF THE ENERGY FOR HEATING FROM A SITE NECOVERED ENERGY OR SOLAR ENERGY SOURCE COMPUTED OVER AN OPEItATING SEASON. 3 pOOI FILTRATION PUMP MOTORS SHALL MEET THE FOLLOWING REQUIREMENTS: 3.a. POOL PUMP MOTORS SHALL NOT BE SPLIT -PHASE, SHADED POLE OR CAPACITOR S TART INDUCTION RUN TYPES 3.b. POOL PUMPS AND POOL PUMP MOTORS WITH A TOTAL HORSEPOWER (HP) OF GREATER THAN OR EQUAL TO 1 HP SHALL HAVE THE CAPABILITY OF OPERATING AT TWO OR MORE SPEEDS. THE LOW SPEED SHALL HAVE A ROTATION RATE OF NO MORE THAN j OF THE MOTOR'S MAXIMUM ROTATION RATE, 3.c_ POOL PUMPS MOTOR CONTROLS SHALL HAVE THE CAPABILITY OF OPERATING THE POOL PUMP AT A MINIMUM OF TWO SPEEDS. THE DEFAULT CIRCULATION SPEED :HALL BE THE RESIDENTIAL FILTRATION SPEED WITH A HIGHER SPEED OVERRIDE (,APABILITY FOR A TEMPORARY PERIOD NOT TO EXCEED ONE NORMAL CYCLE OR 24 HOURS, WHICHEVER IS LESS. EXCEPTION: SOLAR POOL HEATING SYSTEMS SHALL BE PERMITTED TO RUN AT HIGHER SPEEDS DURING PERIODS OF USABLE SOLAR HEAT GAIN, 4. HYDPAULIC SYSTEMS FOR NEW POOLS MUST BE DESIGNED IN ACCORDANCE WITH APSP 15, 'AMERICAN NATIONAL STANDARD FOR RESIDENTIAL SWIMMING POOL AND SPA F NERGY EFFICIENCY." TO GROUND FAULT CIRCUIT INTERRUPTER THEN TO POWER SOURCE WITH TRANSFORMER 4' MIN. JUNCTION BOX RIGID, IMC OR NON METALLIC CONDUIT �z BRASS OR NON METALLIC CONDUIT OR APPROVED EQUIVALENT z 300 WATT UNDERWATER LIGHTS SHALL BE NEC. APPROVED AND SHALL FEATURE STAINLESS STEEL m FORMING SHELL WITH BRASS MOUNTING RING. SHELL SHALL HAVE A 1' NPT CONDUIT WITH OPENING PACKING GLAND. LIGHT SHALL BE HOUSED IN A STAINLESS STEEL ENCAPSULATION BOLTED TO A CHROME PLATED FACE RING FOR COMPRESSING OF A 360° DOUBLE WALL SYNTHETIC GASKET. SS LIGHT FIXTURE 4 NICHE W/ COMPRESSION HUB & 300W.12V LAMP OR 120 VAC W/ GFCI PER NEC LADDER, HAND RAIL, T DIVING BOARD, ETC... POOL LIGHT POOL METAL CONDUITS REINFORCING OR PIPING SYSTEM STEEL FLEXIBLE CORD GROUNDING TERMINAL H -N -G #8 BOND TO #8 BONG TO STRUCTURAL STEEL STRUCTURAL GROUND BAR #8 BOND D STEEL PVC CONDULI CONTROL PANEL TYPICAL GROUNDING SCHEMATIC ELECTRICAL NOTES: 1. GROUND AND BOND ALL POOLS AND RELATED EQUIPMENT IN ACCORDANCE WITH NEC ARTICLES 250 AND 680. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR TO ENSURE THAT ALL METALLIC PARTS OF THE POOL. STRUCTURE, INCLUDING THE POOL SHELL AND DECK REINFORCING BARS AND ALL OTHER METAL PARTS ARE BONDED PER NEC ARTICLE 250 AND 680. BOND TOGETHER REINFORCING BARS USING STEEL TIE WIRES. BOND ALL METAL PARTS TO POOL REINFORCING BARS USING #8 AWG COPPER WIRES. THESE METAL PARTS INCLUDE, BUT ARE NOT LIMITED TO LADDERS, RAILINGS, PIPING, CONDUIT, METAL DOOR FRAMES AND METAL PARTS WITHIN F OF INSIDE WALL OF POOL. CONNECTION SHALL BE EXOTHERMIC WELD, LISTED PRESSURE CONNECTORS OR CLAMPS AS APPLICABLE. GROUND STEEL COLUMNS (I.E. FOR TOWERS OR SLIDES) PER NEC ARTICLE 250 AND 680 AND NFPA 780. IF REINFORCING BARS ARE ENCAPSULATED WITH A NON CONDUCTIVE COMPOUND, CONTACT ENGINEER BEFORE PROCEEDING. 2. THIS ELECTRICAL INSTALLATION SHALL MEET ALL REQUIREMENTS OF NEC ARTICLES 250 AND 680. IN ACCORDANCE WITH THIS, UNDERGROUND WIRING SHALL NOT BE PERMITTED UNDER THE POOL OR WITHIN F HORIZONTALLY FROM THE INSIDE WALL OF THE POOL UNLESS THIS WIRING IS NECESSARY TO SUPPLY POOL EQUIPMENT PERMITTED BY NEC ARTICLE 680. ALL RECEPTACLES SHALL BE LOCATED AT LEAST 19 FROM THE INSIDE WALL OF POOLS. ALL RECEPTACLES WITHIN 20' OF THE POOL SHALL HAVE GFCI PROTECTION. ADDITIONALLY, ALL UNDERWATER LIGHTING SHALL BE GFCI PROTECTED. MOUNTING HEIGHT FOR ANY LIGHT FIXTURES SUSPENDED OVER POOLS SHALL BE NOT LESS THAN 12' ABOVE MAXIMUM WATER LEVEL. 3. IF APPLICABLE, PROVIDE #12 AWG CONDUCTORS AND GROUND FOR 12V UNDERWATER LIGHTING CIRCUITS LESS THAN 81N LENGTH. FOR 12V CIRCUITS 8' TO 15' IN LENGTH, PROVIDE #8 AWG CONDUCTORS AND GROUND. FOR 12V CIRCUITS GREATER THAN 16, BUT LESS THAN 25' LN LENGTH, PROVIDE #6 AWG CONDUCTORS AND #6 GROUND. NO 12V CIRCUIT SHALL BE MORE THAN 25' IN LENGTH. 4. OPTIONAL: ELECTRICAL CONTRACTOR SHALL INSTALL NO FEWER THAN ONE 125 -VOLT 15 - OR 20 -AMPERE RECEPTACLE ON A GENERAL PURPOSE BRANCH CIRCUIT. RECEPTACLE SHALL BE LOCATED NOT LESS THAN 10 FT. FROM AND NOT MORE THAN 20 FT, FROM THE INSIDE WALL OF THE POOL. THE RECEPTACLE SHALL BE LOCATED NOT MORE THAN 6 FT. 61N. ABOVE THE FLOOR, PLATFORM, OR GRADE LEVEL SERVING THE POOL. 5. RECIRCULATION PUMP SHALL BE ELECTRICALLY INTERLOCKED WITH CHEMICAL EQUIPMENT, IF APPLICABLE. 6. AN EQUIPOTENTIAL COMMON BONDING GRID IS REQUIRED FOR ALL PAVED WALKING SURFACES WITHIN THREE FEET OF THE INSIDE WALLS OF THE POOL AND/OR SPA FOR THE ENTIRE POOL PERIMETER. THE BONDING GRID MAY BE COMPOSED OF STEEL REINFORCING RODS (REBAR), OR #8 BARE, SOLID COPPER CONDUCTORS. 6 X 6 X 10 WELDED WIRE FABRIC (MESH) IS ACCEPTABLE WHEN PROPERLY INSTALLED ON CHAIRS AND EACH SECTION IS CLAMPED WITH APPROPRIATE LISTED DEVICES AND/OR #8 SOLID COPPER JUMPERS. THE BONDING GRID MAY NOT BE INSTALLED DIRECTLY IN EARTH CONTACT OR WITHOUT PROPER COVER. THE INSTALLATION MUST BE IN ACCORDANCE WITH 680.26(C), NATIONAL ELECTRIC CODE (NEC - LATEST VERSION) AND FLORIDA BUILDING CODE (FBC - LATEST VERSION) W/ LATEST AMENDMENTS. T THE FOLLOWING IS AN ACCEPTABLE ALTERNATIVE TO THE BONDING GRID DEFINED IN NOTE #6, ABOVE: AN UNDERGROUND BONDING CONDUCTOR MADE OF A SINGLE #8 AWG BARE SOLID COPPER WIRE BURIED TO A MINIMUM DEPTH OF 4 INCHES TO 61NCHES BELOW SUBGRADE AND 18 INCHES TO 24 INCHES FROM INSIDE WALL OF THE SWIMMING POOL OR SPA. THIS IS DEFINED A PERMISSIBLE ALTERNATIVE OR EQUIVALENT TO COMPLIANCE WITH S.680.26(C) OF THE NEC (2017), NFPA 20, ADOPTED BY REFERENCE WITHIN FBC. #8 AWG PRESSURE GROUND—/ v PLANS VALID FOR THIS CONNECTOR G WITH EI COMMON PLANS EXPIRE. BONDINSTEELORPLUMBING BUILDING DEPT. ONLY. STEEL OR PLUMBING POOL LIGHT DETAIL MARCH 19, 2019 JUNCTION BOX (IF USED) RANORMER CITY OF ATLANTIC BEACH SF POOL LIGHT HEATER CASE DQ" RESIDENTIAL CONTROL�%ELECTRICAL NOTES PANEL Certificate of Authority No. 28177 =1N g 4A3CKSPABLO�O�URT, S `ITE 101 AND DETAILS e• CE •• �F'�,= THE BATTS COMPANY PUMP MOTOR • : ' `�� CPC037046 - CGCO55163 e a 14 1602 NORTH 3RD STREET JACKSONVILLE BEACH, FL 32250 * ! (904)246-2455(904)249-0457 `O 9rF TYPICAL BONDING SCHEMATIC* =-� Q ' 44 •°ems', RI D P•®V�/;a DWG. BY: MAC \\ ``` NOT TO SCALE SHEET 5 OF 5 APPROVED BY: JEL� -